Spectral Dynamics Sine Control CATS Control Methods User Guide
पीडीएफ
दस्तावेज़
विज्ञापन
विज्ञापन
C CA AT TSS SSiinnee C Coonnttrrooll Sine testing can be done two ways: 1. Overall test level control, where we do not care about what frequency causes the response energy. 2. Fundamental Control, which requires Tracking Filters. See Figure 2 below Nearly all tests presume Tracking Filters are being employed. PUMA provides True analog quality tracking filters created in DSP with the same Sine-Co-Sine Heterodyne method SD patented in 1961, If you must test to MilStd expectations, you must use tracking filters. FFT based processes DO NOT yield the same accuracy that Digital Tracking Filters offer. Signal Generation hardware matters. PUMA generates harmonic free analog quality Sine signals that permit remarkable resonance control and accuracy. NOT generating Harmonic content, means the power amplifier WON’T receive high frequency energy which it CANNOT reproduce, thereby removing another worry from the Test Professional’s mind. Figure 1 • Analog quality sine signal generation • Multi-channel digital tracking filters with variable fixed and proportional bandwidths • Digital re-sampling provides true proportional bandwidth tracking filters • Sweep range from 0.1 to 10,000 Hz • Optional resonance search and phase- tracked dwell • Frequency Response Function (FRF) measurements for all active channels • Independent limit profiles for each active measurement channel Figure 2 Graphics so POWERFUL, the user interface can be simple CATS Sine Control Methods Control loop Control Performance Dynamic range Output signal Level accuracy Loop time Compression rate Harmonic distortion Reference Profile Definition Segment types Crossover frequencies Alarm and abort limits Sweep range Sweep resolution Spectrum dynamic limits Limit Profiles (optional) Definition Segment types Crossover frequencies Number Control Parameters Mode of operation Test duration Measurement processing Tracking filter types Transducer types Number of control channels Multi-channel control strategy Abort channels Compression Units Box Tolerance Enable Startup/Shutdown Rate Sweep Parameters Sweep mode Sweep duration Number of sweeps Sweep rate-linear Sweep rate-logarithmic Initial sweep direction Safety Features Shaker limits Technical Specifications True analog-quality sine sweep with a double precision integrated phase algorithm for low distortion Greater than 80 dB with 0.05 dB level step control over the full range Analog-quality digital sine generation, using a double precision integrated phase algorithm for low distortion Control to within ± 1 dB at a sweep rate of1 oct/min through a 600 Hz resonance of a linear system with a Q of 70 with an internal 20% proportional tracking filter Sweep frequency resolution±0.5% of the drive frequency Less than 5 msec for single channel control Up to 3,500 dB/sec with unconditionally stable feedback control loop < -75 dB at full output Up to 500 frequency segments Constant displacement, velocity, acceleration, and straight line acceleration (linear or logarithmic) Automatically calculated to avoid segment boundary discontinuities Independent positive and negative alarm and abort margins User-defined sweep range from 1 to 5000 Hz; and 0.01 to 10000 Hz (Premier) optional User-defined resolution of 450 to 800 points per sweep; 450 to 2400 points per sweep (Premier) optional Acceleration range, maximum or minimum acceleration, maximum velocity and maximum displacement Up to 500 frequency segments Constant displacement, velocity, acceleration, and straight line acceleration (linear or logarithmic) Automatically calculated to avoid segment boundary discontinuities Up to the number of active channels minus one (Premier) Manual, automatic Maximum 99,999 sweeps or 9999:59:59 (hhhh:mm:ss); unlimited test RMS, or tracking filter processing for all channels in parallel; processing type individually selectable for each channel Proportional to drive frequency, 1 to 200% and fixed bandwidth, 1 Hz to 1,000Hz Control based on acceleration, velocity, displacement (transducer with programmable transition frequency band) 1 to all available channels, max 16 RMS, arithmetic average, min, max Abort test when user-defined level exceeded 5% to 100% m/s2 - m/s - mm; g – in/sec - in; g - m/s – mm Alarm & Abort width set 0 to 100% 1 to 99 dB/sec Linear, logarithmic User-defined, maximum 999:59:59 (hhh:mm:ss) 0.01 to 100,000 0.00003 to 300 Hz/sec (0.0018 to 18,000Hz/min) 0.1 to 800 Oct/min Up, down Pretest verification that spectrum dynamic limits are within shaker operational limits (acceleration, velocity, displacement and voltage) Spectral Dynamics, Inc. 2730 Orchard Parkway San Jose, CA 95134 TEL. 408.678.3500 FAX. 408.678.3580 Loop check max. drive Control signal loss Manual abort Maximum drive signal Startup/shutdown rates Test Automation Test scheduling Sweep rate table Compression table Schedule cycles Print Automation Base Engineering Units Engineering Units Calculations Channel Setup Channel type Sensitivity Channel loop check Channel label Transducer serial number Transducer Database On-Line Test Analysis Display functions Cursors Scaling of display Real-time/stored data Passive Sine Analysis Resonance Search & Dwell (optional) Dwell modes Search parameters Q Search Smoothing Search Channel Phase Reference Channel Resonance calculation Dwell table parameters Dwell level type Data Storage Setup options Playback Documentation Test summary Run message log Safety Features Shaker limits Loop check max. drive Control signal loss Manual abort Maximum drive signal Startup/shutdown rates User-selectable, 0 to 5,000 mV RMS Continuous automatic detection Graphical and keyboard abort buttons 0.0001 to 12 V peak Independently selectable, 1 to 99 dB/sec User-defined sequence of up to 500 independent tests run automatically Up to 50 sweep rate vs. frequency segments Up to 50 compression speed vs. frequency segments 1 to 100 Ability to create reports Automatically with Customized displays Label(EU), Conversion(EU/Transducer Units) Integrated (Label and Scale Factor), Double Integrated(Label and Scale Factor), Differentiated (Label and Scale Factor), Double Differentiated (Label and Scale Factor) Control, measurement, reference, limit, abort, inactive 0.001 to 999,999 mV/g or mV/(m/s2) mm; EU for Measurement Channels Enabled, disabled Up to 20 characters for each channel Up to 10 characters for each channel Table Driven Archival Database Control, drive, measurement channel 1 to 32, frequency response function (magnitude/phase or real/imaginary X and Y value readout, peak search, trace tagging, multi-window looked positioning Log/linear, auto-scaled/fixed Simultaneous display and overlay of real-time data and any stored data Same capability as test operations w/o output generation Fixed frequency, phase tracked(auto/manual), Continuous ( w/reset option) Max no. of resonances, hysteresis, minimum Q value Peak Ratio or –3dB points Low, Medium, High Any active channel Any active channel Resonance frequency, Q, phase, level Duration, start frequency, dwell frequency, end frequency, dwell level and phase, alarm limit, abort limit Acceleration, velocity, displacement Sweep Increment, first sweep, last sweep Scan through the entire test data file, with adjustable delay and Tagging Fully documented post-test summary, easily printed or incorporated into any document using standard word processing software Text file records all system status messages displayed during test run Pretest verification that spectrum dynamic limits are within shaker operational limits (acceleration, velocity, displacement and voltage) User-selectable, 0 to 5,000 mV RMS Continuous automatic detection Graphical and keyboard abort buttons 0.0001 to 12 V peak Independently selectable, 1 to 99 dB/sec In keeping with our commitment to continuous product improvement, the information herein is subject to change. Copyright 2005 Spectral Dynamics, Inc. All rights reserved. CATS and STAR logos are registered trademarks or Spectral Dynamics Inc. All other trademarks are properties of their respective owners. www.spectraldynamics.com TSPUMASN0301 ">
/
डाउनलोड
बस एक दोस्ताना अनुस्मारक. आप दस्तावेज़ को यहीं देख सकते हैं. लेकिन सबसे महत्वपूर्ण बात, हमारे एआई ने इसे पहले ही पढ़ लिया है. यह जटिल चीजों को सरल शब्दों में समझा सकता है, किसी भी भाषा में आपके सवालों के जवाब दे सकता है और सबसे लंबे या सबसे जटिल दस्तावेजों को भी जल्दी से नेविगेट करने में आपकी मदद कर सकता है.
विज्ञापन