AC Power
For Business-Critical Continuity™
Liebert
®
NX
™
Rapid and unpredictable growth in fast-paced data centers makes it challenging to protect critical network equipment and other electronic components. Liebert NX with Softscale is the solution.
Liebert NX with Softscale is a true on-line, double conversion, three-phase UPS that delivers complete, centralized power protection for mission-critical systems. Designed to meet the high availability power needs of a wide variety of IT applications, this power solution delivers advanced operating features d l t f hi
Ideal Applications
Small to mid-size data centers (10-30 racks)
High density blade deployments
High performance clusters
IT t i i di t bl
K b fi
Flexibility
Solution provides UPS, matching battery cabinet and bypass/distribution cabinet, enabling fast and reliable powering of new racks and growing computing loads
Softscale technology allows increased UPS capacity without changes to your infrastructure
Easily add matching battery cabinets for greater runtime
Compatible with the Liebert FS Flywheel Solution for use with or in place of traditional batteries
UPS modules can be paralleled for capacity and/or redundancy with the optional paralleling cabinet
Higher Availability
True on-line double conversion UPS ensures reliable, l iti IT i t
Built-in internal bypass and wrap around maintenance bypass allows preventive maintenance and service without having to power down IT loads
Advanced Ntegrated Monitoring from Liebert
Services provides 24x7x365 proactive diagnostics and trending analysis to track unit health and capacity
1 year full parts and labor warranty features 24 hour on-site service provided by the largest and most experienced service organization in the industry
Lowest Total Cost of Ownership
Eco-Mode high efficiency configuration (up to 97%) saves on energy spending
Soft-switching technology enables the same high efficiency at 40% utilization as at 100% utilization
Digital signal processor control technology increases reliability through reduced component count while enhancing efficiency and waveform accuracy to maximize operating life of sensitive IT equipment
Liebert NX UPS System is the Right
Solution for Growing Data Centers
h b b l d d technology, matched system components, an easy ordering process, and unsurpassed support. The result is a solution that perfectly powers growing data centers.
Support from Installation Through Operation
Installation, Maintenance, Service and Reporting from Emerson
Network Power factory-trained service professionals — your assurance that Liebert NX operates reliably.
One Year Free Service with Ntegrated Monitoring from Liebert Services
Ntegrated Monitoring from Liebert Services incorporates advanced monitoring and leading network security to provide an integrated approach to alarm management, equipment maintenance and emergency service response.
• 24x7x365 proactive remote diagnostic and trend analysis to track unit health and capacity
Centralized monitoring by the
Liebert Services High Availability
Response Center (HARC) with service dispatch to diagnose and respond to potential problems
Combined remote and on-site service
Easy to read monthly electronic health reports
Sample
Monthly
Report
Liebert NX UPS
On-line, double conversion UPS with
Softscale™ technology allows you to pay for only the capacity you need today; as your needs change, a simple software upgrade allows you to grow from
60kVA
80kVA; or from 80kVA to 100kVA to 120kVA.
Liebert NX Bypass
Distribution
Matching cabinet bolts directly to right side of the UPS. It features a keyed interlocked bypass breaker, optional voltage transformation and output distribution with panelboards or subfeed breakers.
Liebert NX Battery
Cabinet
Valve Regulated Lead
Acid (VRLA) batteries provide mission critical back up. High reliability features include 10-year design life batteries with flame retardant cases, factory installed battery circuit breaker protection, and optional
Albér battery monitoring for early warning detection of
Liebert NX UPS
Paralleling Cabinet
Increase UPS capacity or add redundancy with the addition of the NX Paralleling
Cabinet. Parallel up to three UPS modules for capacity, and add a fourth for redundancy.
A Complete Power Solution that grows with IT loads
Selecting a Liebert NX System:
1
Determine the total IT load to be supported by the UPS
Add up the kVA/kW requirements of your racks and select a UPS model with a rating greater than the total. Select a higher rating to allow for growth, while keeping in mind that you have the built-in flexibility to upgrade to the maximum Softscale capacity after installation. Models are available with a Softscale capacity of 80kVA or 120kVA.
2
Confirm availability of
480VAC power to the UPS
480V power is required for the
Liebert NX System.
3
Confirm where you will be locating your
UPS, batteries and PDU on site
Recommended configuration is: Battery
Cabinet(s), UPS, BDU. inter-unit cabling is provided for this configuration only. Cabling from the PDU to load is user-supplied
The UPS and batteries require only front access and can be located either in the rack row, against a wall, or in an adjacent room .
The PDU requires both front and rear access and is recommended to be located close to e oad.
4 Determine your battery runtime requirement at full load. For more runtime, add additional battery cabinets to your order:
UPS Description
40kVA (40-80 model)
60kVA (40-80 model)
80kVA (40-80 model)
80kVA (80-120 model)
100kVA (80-120 model)
120kVA (80-120 model)
Base Runtime
(Minutes)
20
11
7
20
15
12
Battery Cabinets for Base Runtime
One (1)
One (1)
One (1)
Two (2)
Two (2)
Two (2)
+1 Cabinet
(Minutes)
45
28
20
34
25
21
+2 Cabinets
(Minutes)
72
46
34
45
35
30
+3 Cabinets
(Minutes)
101
64
45
N/A
N/A
N/A
Order your Liebert NX
5 If you need additional configuration assistance, work with your Dell sales team to engage a local Liebert sales consultant or call
1-800-LIEBERT.
1 UPS Capacity
Maximum Softscale Capacity of UPS
PDU Capacity
2
Power Input to UPS
Power Output to Load
4
5
Required Breaker Size
Floor Space Requirement in
Rack Widths
(Battery/UPS/PDU)
Base Runtime (Minutes)
Dell NX UPS Bundle SKU
Extra Battery Cabinet SKU
40kVA /
36kW
80kVA /
72kW
75kW
480VAC
120/208VAC
175A
20
A2206257
A2206264
Liebert NX Model Selection Chart
60kVA /
54kW
80kVA /
72kW
80kVA /
72kW
75kW
80kVA /
72kW
75kW
480VAC
120/208VAC
175A
480VAC
120/208VAC
175A
80kVA /
72kW
120kVA /
108kW
125kW
480VAC
120/208VAC
250A
100kVA /
90kW
120kVA /
108kW
125kW
480VAC
120/208VAC
250A
11
A2206258
A2206264
7
A2206259
A2206264
20
A2206260
A2206264
15
A2206261
A2206264
120kVA /
108kW
120kVA /
108kW
125kW
480VAC
120/208VAC
250A
12
A2206262
A2206264
Liebert NX System Specifications
System Rating - kVA (kW)
Maximum Softscale Capacity - kVA (kW)
UPS Technology
Battery Technology
Power Factor
Nominal Input Voltage - VAC
Input Voltage Range - VAC
Frequency - Hz
Input breaker size
Nominal Output Voltage - VAC
Frequency - Hz
Liebert NX Power System
40 (36) 60 (54)
75 (72)
General Specifications
75 (72) 80 (72) 100 (90)
120 (108)
On-line, double conversion
Non-Spillable, Flame Retardant, Valve Regulated Battery, 10-Year Design Life
Input AC Specifications
175A 175A
Output AC Specifications
>0.99 at full load, >0.98 at half load
480, 3 wire + ground
552 - 360 (+15%, -25%)
60 nominal (57-63)
175A 250A
208 / 120, 4 wire + ground
60 +/- 0.5%
250A
120 (108)
250A
System Dimensions (WxDxH) - in. (mm)
UPS Dimensions (WxDxH) - in. (mm)
Battery Dimensions (WxDxH) - in. (mm)
Bypass Distribution Dimensions (WxDxH) - in. (mm)
Shipping Dimensions, Each Box (WxDxH) - in. (mm)
System Weight - lbs. (kg)
UPS Weight - lbs. (kg)
Battery Weight - lbs. (kg)
PDU Weight - lbs. (kg)
System Shipping Weight - lbs. (kg)
UPS Shipping Weight - lbs. (kg)
Battery Shipping Weight - lbs. (kg)
PDU Shipping Weight - lbs. (kg)
UPS Monitoring
Distribution Monitoring
Operating Temperature Range - °F (°C)
Storage Temperature Range - °F (°C)
Audible Noise - dB, A-weighted
Safety Certification
Warranty
Remote Monitoring
Physical Specifications
80.6 (2047) x 39.0 (991) x 78.5 (2000)
23.6 (600) x 39 (991) x 78.5 (2000)
112.1 (2847) x 39.0 (991) x 78.5 (2000)
23.6 (600) x 39 (991) x 78.5 (2000)
33.2 (845) x 39 (991) x 78.5 (2000)
24.4 (620) x 39 (991) x 78.5 (2000)
66.4 (1690) x 39 (991) x 78.5 (2000)
24.4 (620) x 39 (991) x 78.5 (2000)
48 (1220) x 48 (1220) x 84.5 (2146)
6030 (2735)
1290 (585)
2620 (1188)
1350 (612)
5860 (2658)
8312 (3770)
1422 (645)
5240 (2376)
1650 (748)
9112 (4133)
1490 (676)
2820 (1280)
1550 (703)
Monitoring Specifications
SNMP / Web Based Monitoring Card Included
Local LED display of system output voltage and current
Environmental Specifications
1622 (736)
5640 (2560)
1850 (839)
32 to 104 (0 to 40)
-4 to 104 (-20 to 70)
<62 <64
UL 1778 (UPS) / UL 60950 (PDU)
Product Support
1 Year, Full Parts and Labor
1 Year of Ntegrated Monitoring ™ included free of charge.
Option to renew with annual service contract.
Liebert NX bundle one-line diagram
Liebert Corporation
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
800 877 9222 Phone (U.S. &
Canada Only)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
Italy
39 049 9719 111 Phone
39 049 5841 257 FAX
Emerson Network Power Asia Pacific
108 Gloucester Road
Wanchai
Hong Kong
852 2572 2201 Phone
852 2519 9210 FAX liebert.com
24 x 7 Tech Support
614 841 6755 (outside U.S.)
While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
© 2009 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.
® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation.
VR-01449 (03/09) Printed in USA
Bypass Distribution Cabinet
Emerson Network Power.
The global leader in enabling business-critical continuity.
AC Power
C ti it
DC Power
Embedded Power
Monitoring
Outside Plant
Power Switching and Controls
Precision Cooling
Racks and Integrated Cabinets
Services
Surge Protection