Frigidaire FGHB2866PE Wiring diagram
Add to my manuals
2 Pages
Frigidaire FGHB2866PE is a refrigerator with a variety of features to keep your food fresh and organized. It has an adjustable thermostat, so you can set the temperature to your liking, and a humidity-controlled crisper drawer to keep fruits and vegetables fresh longer. The refrigerator also has a door alarm that will sound if the door is left open for more than 5 minutes.
advertisement
▼
Scroll to page 2
SERVICE DATA SHEET PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING Type A with Run / Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient 90 to 100% 100% -5° to 2°F (-20° to -17°C) -1° to 3°F (-18° to -16°C) 34° to 39°F (1° to 4°C) 34° to 39°F (1° to 4°C) -2 to 6 psig (-14 to 41 kPa) -2 to 6 psig (-14 to 41 kPa) 85 to 105 psig (586 to 724 kPa) 120 to 135 psig (827 to 931 kPa) Operating Time Freezer Temperature Refrigerator Temperature Low Side Pressure High Side Pressure (last 1/3 cycle) Wattage (last 1/3 cycle) 30 to 50 50 to 70 Amps (running) .4 to .8 .7 to .9 Base Voltage A01544601 ICE & WATER - AUTOMATIC DEFROST ERROR CODES Display DEFROST SPECIFICATIONS Heater Cabinet Size: 27’ & 28’ SD, 22’ CD IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. 26.5 39°F (4°C) Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time. CONDENSER FAN MOTOR 0.03 Running F + and - / same to deactivate 77 77 ٨ and - / Power-on-Reset (POR) -- SH Shorted FF Thermistor Sabbath Sb Sb ٧ and - / same to deactivate Shorted FZ Thermistor System Diagnostic No FF or FZ display, all UI LEDs on. ٨ and ٧/ + to deactivate UI to Main Control Board communication failure; on start up FFIM Diagnostic Numerical display of first test ٨ and ٧ together to activate / press and hold + to deactivate UI to Main Control Board communication error; after a period in operation Notes: • Always check for pin back-outs, pinched or damaged wires before replacing components. • Determine whether failure is caused by the component, main control board or wiring. Contact TID before replacing main control board. • Refer to Service Manual for additional information. EF 500 1100 CW Opposite Shaft d Display / Showroom SY 135°F (57.2°C) 3.1 Manual Defrost Open FZ Thermistor CE 110°F (43.3°C) Amps Open FF Thermistor -- SY Cut-out -- Activate: 115 vac (127 vac max) Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C) Heater Voltage 115 vac Deactivate: 52C LINE NEUTRAL POWER MOTOR 63C P-4 THERMOSTAT NO BLU BLK C MOLD HEATER 165 WATTS NO GRN / YEL P-1 C MOLD MOUNTING PLATE ICE MAKER NC WATER FILL SWITCH RED NC C Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode. Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through. View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests. Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests. Test To activate test: NC SHUTOFF SWITCH First Screen -- All LED lights on UI illuminated. -- Second Screen -- All segments on UI temperature displays illuminated. -- Third Screen -- Blank UI display, no lights illuminated. 28 Dispenser Paddle Press disp. paddle “on” on UI when depressed; “off” when released. 46 Humidity Sensor Activates automatically “OP” if open, “SH” if short. AC Heater System: Displays %RH. DC Heater System: “HI” – heater should be on. “Lo” – heater should be off. %RH is displayed when humidity is between “Lo” and “HI” values; heater could be on or off. 47 Dispenser Pocket Heater Press set AC Heater System: “--” ; test not available. DC Heater System: heater on when “on”, off when “off”. 2 Freezer Defrost Heater Press set Freezer defrost heater on when “on”; off when “off”. 3* FF Light (Incandescent Models) Press set FF lights on when “on”; off when “off” 8 Water Valve (Dispenser) Press set FF doors must be closed. Be prepared to collect water at dispenser. Water dispenses when “on”; stops when “off”. 9* FZ Light (Incandescent Models) Press set FZ lights on when “on”, off when “off”. 10 Auger Motor Press set FF door must be closed. Motor running when “on”; motor stopped when “off”. 11 Cube/Crush Solenoid Press set FF door must be closed. Do not leave solenoid in activated state. Solenoid activated when “on”; deactivated when “off”. VCC Condenser Fan Press set Fan running when “on”; stopped when “off”. 43 Anticondensation Heater Press set Flip mullion heater and dispenser pocket heater on when “on”; off when “off” Test 38* VCC Compressor Press set Compressor running when “on”; stopped when “off”. 13* FF Light (LED Models) Press set FF lights on when “on”; off when “off”. 15 Evaporator Fan Press set Stopped when “off”. Listen for speed change from “LO” to “HI”. 20* FZ Light (LED Models) Press set FZ lights on when “on”, off when “off”. 22 Damper Press set With inspection mirror, observe damper open when “OP”; closed when “CL”. 23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open. 24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open. 26 Ice Maker Defrost Heater Activates automatically Relay is activated automatically. If “CL” is shown, defrost limit switch is closed and heater should be heating up. If “OP” is shown, defrost limit switch is open and heater will not activate. 29 FF Thermistor Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of temperature measured with gauge at FF thermistor location. “OP-” if open; “SH-” if short. 30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature measured with gauge at FZ thermistor location. “OP” if open; “SH” if short. 33 Ambient Thermistor @ Main Board Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F of temperature measured with gauge at main board location. “OP” if open; “SH” if short. 34* Ambient Thermistor @UI Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of temperature measured with gauge at UI location. “OP” if open; “SH” if short. 39 Evaporator Thermistor Activates automatically UI shows temperature sensed by evaporator thermistor; pass if within 10°F of temperature measured with gauge at evaporator thermistor location. “OP” if open; “SH” if short. 45 Ice Maker Mold Thermistor Activates automatically UI shows temperature sensed at ice maker; pass if within +20°F/-10°F of temperature measured with gauge at ice maker mold. “OP” if open; “SH” if short. 0- Firmware Parameters Press set Displays digit sequence; record. 2- Main Board Firmware Press set Displays digit sequence; record. 4- UI Firmware Press set Displays digit sequence; record. Passing Result To activate test Activates automatically FZ display shows temperature sensed by Ice Maker Thermistor. “OP” if open; “SH” if short Press Set Remove ice tray to collect water into a measuring container to measure water fill. If collecting water into ice tray, first perform test 63C to empty ice tray. Evaporator Fan (FFIM) Press Set “On” on FZ display when fan activated, “OFF” when deactivated. Ice Level Sensor Activates automatically Remove ice bucket. Allow bail arm to drop freely. Pass if no alarm when tray returns to “home” position. Hold bail arm up. Pass if alarm sounds when tray returns to “home” position. This test runs continuously until another test is selected. Twist Tray Press Set Remove ice bucket. FZ display shows “1” and “GOOD”. YELLOW P-2 Variable Capacity Compressor (VCC) Diagnostics (select models) If test 38 fails, diagnose as follows: → Check at the connector from the power cord harness into the inverter board, located in the machine compartment. (PUR and WHT wires) CAUTION FREEZER ICE MAKER INFORMATION Water Fill Adjustment Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked. → Check at Main Control Board (BLK/WHT and RED/BLK wires) yes Identify and repair damaged wires or poor connections between Main Control Board and Inverter Board. Motor Gear TU R Mounting Plate Screws Mounting Plate Screw Remove inverter box from the compressor and check resistance across compressor winding pairs as shown. Is resistance across all winding pairs equal? → yes Check connections from Inverter Board to Compressor Are connections from Inverter Board to Compressor intact? no Replace Compressor and Inverter Board. Is Main Control Board sending 10-15 VAC and 1-5 VDC to Inverter Board? N Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle. → yes no Check voltage supply. Check and repair power cord harness wiring and connections. (Where Applicable) Check at Inverter Board on Compressor (BLK and RED wires) Is Inverter Board receiving 10-15 VAC and 1-5 VDC from Main Control Board? no • All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner. → yes Is Inverter Board receiving 115 VAC from power supply? • Passing result -- LT. BLUE NO WATER VALVE RED Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity. Note: Silence alarm. 12 58C RED HOLD SWITCH ICE MAKER BLK THERMAL CUT-OUT Deactivate: Press + for up to 10 sec. FFIM Diagnostic Mode will automatically deactivate after 5 min. of inactivity. NOTE: Silence alarm. Water Valve 57C LT. BLUE ICE MAKER BRN BLK Press ٨ and ٧ temperature pads for up to 10 sec. simultaneously. Press + or - to move forward or backward through tests. Ice Maker Thermistor 55C ICE MAKER P-3 Evaporator Fan Failure FRESH FOOD ICE MAKER DIAGNOSTIC MODE FREEZER ICE MAKER SPECIFICATIONS Electrical FF OP CF Ohms FZ Activate/Deactivate (press for up to 10 sec. simultaneously) -- SY Watts Display Mode OP SH Cut-out RPM FF Defrost Thermistor Termination Cut-in Watts FZ SPECIAL MODES Interpretation Press ٨ and ٧ for up to 10 sec. simultaneously. Press + to advance through tests. • • • • BOTTOM FREEZER - R134a 115 vac (127 vac max) Thermal Cutout SYSTEM DIAGNOSTIC MODE Activate: no no Identify and repair damaged wires or poor connections between Inverter Board and Compressor. yes Replace Main Control Board. VCC Resistance Check Check resistance between terminals 1 and 2, 2 and 3, 3 and 1. If all resistances are equal, compressor is operative. Replace Inverter Board IMPORTANT SAFETY NOTE The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance. IMPORTANT Timing Gear If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured. 1 5 2 4 J3 3 6 9 10 DC SIDE FLAPPER MOTOR BLK USER INTERFACE 3 2 1 J4 LED LIGHT WIRING PIN 3 PIN 4 PIN 5 PIN 3 PIN 4 PIN 5 LH2 RH2 WHT RED 1 2 J9 3 4 AC SIDE GND 2 FREEZER SENSOR AT1 1 2 3 4 1 2 3 4 WHT/BLU WHT/BLU WHT/BRN WHT/BRN LED LED LED RG-2 RG-6 WHT/BLU IM FAN MOTOR RG-3 RG-4 LED LED WHT/BRN RG-1 RG-7 WHT/BRN WHT/BRN WHT/BLU WHT/BLU WHT/BRN WHT/BRN WHT/BLU WHT/BLU BLK M 2 PIN 4 PIN 7 1 PIN 1 PIN 8 GRN/BLU M BAIL ARM SWITCH 4 3 2 1 MB1 2 RED 1 DK. BLU TWIST MOTOR 4 3 2 1 GRY/WHT 1 TRAY SENSOR REFRIGERATOR LEDS IM1 PIN 2 PIN 4 PIN 1 PIN 8 PIN 2 PIN 3 PIN 1 PIN 7 PIN 5 PIN 2 PIN 4 PIN 6 PIN 6 PIN 5 PIN 3 PIN 1 IM2 MC2 GRY/BLK GRY/BLK GRN/BLU DK. BLU WHT RED BLU YEL GREY GREY 1 8 2 3 J7 4 7 5 6 COMM. NEUTRAL +5V DC CAB. GROUND +12V DC WHT/GRN 4 3 2 1 WHT/RED WHT/BRN WHT/GRN WHT/GRN WHT/RED WHT/RED 4 WHT/GRN 3 2 WHT/RED 1 WHT/RED WHT/BRN WHT/BLU WHT/BLU EVAPORATOR FAN (DC) FZ-2 LED LED FZ-1 4 PIN 2 1 PIN 1 2 PIN 3 YEL/WHT RED/WHT BRN/WHT MB1 FREEZER LEDS RED COMPRESSOR CONTROL SIGNAL TYPICAL LED CONNECTOR BLK RED/BLK 1 BLK/WHT 2 RL5 RL4 +5V DC RL8 AT1 12V DC DAMPER MOTOR RED/YEL RED/YEL BRN/YEL PIN 5 BRN/YEL BLK/YEL WHT/YEL BLK/YEL PIN 3 WHT/YEL PIN 2 YEL/BLK (COM) YEL/GRY (N/C) LH LIGHT SWITCH (DOOR OPEN) PURPLE (N/O) PURPLE (COM) 1 2 4 6 PIN 5 PIN 8 YEL/PNK FREEZER DOOR SWITCH (DOOR OPEN) YEL/GRY YEL/GRY YEL/PNK BLK/ORN BLK MB1 PIN 4 PIN 5 YEL/PNK YEL/PNK RIBBED (NEUTRAL) LT. BLU 12 VDC GRN/YEL BASE PLATE GROUND BLK 7 4 J3 U2 (SSR1) RL9 +12V DC RL7 REVERSIBLE 12V DC 6 J3 3 5 YEL/RED 11 12 11 J5 7 12 J5 8 RIGHT DOOR FLANGE FLIP MULLION COVER RIGHT HINGE GROUND PIN 2 YEL/BLK PIN 3 LT.BLU/BLK PIN 9 PIN 6 PIN 1 LT. BLU BLK RED PIN 1 1 PIN 2 3 RH3 SPLICE PIN 1 RH1 CONDENSER FAN PIN 4 LT. BLU/BLK LT. BLU/WHT RH3 LH1 LH2 RH2 TAN DISPENSER WATER VALVE LT. BLU SPLICE +5V DC MAIN INLET WATER VALVE SPLICE TAN/YEL SPLICE SPLICE DIODE YEL/BLU +5V DC YEL/BLU LINE RL1 +12V DC +12V DC GND 1 5 J1 4 J2 FREEZER ICEMAKER WATER VALVE PIN 1 BLK BLK PIN 3 LT. BLU PIN 2 BRN BLK/ORN YEL/PNK PIN 4 FREEZER EVAPORATOR HEATER MB2 3 RL6 OUT1A 1 J3 2 J2 2 BROWN/BLUE BLU/WHT AUGER MOTOR ICEMAKER EVAPORATOR HEATER BROWN PIN 7 PIN 1 BLU/WHT PIN 3 PIN 8 PIN 2 PUR/BLK PIN 9 DEFROST BIMETAL CUBE/CRUSH SOLENOID AUGER MOTOR PURPLE PIN 7 J3 1 BEHIND FRONT LEFT ROLLER PIN 5 MC1 OUT2A RL3 GRN/YEL COIL COVER GROUND OUT1B OUT2B YEL/BLU 2 IM1 RL2 FREEZER DOOR SWITCH (DOOR OPEN) 4 FREEZER ICE MAKER (SEE FZ ICE MAKER DIAGRAM) ERF2500++ISO REFRIGERATOR CONTROL YEL/PNK THERMAL CUT-OUT PIN 4 RH1 +5V DC BOARD-MOUNTED AMBIENT THERMISTOR SPLICE PURPLE (COM) PURPLE (N/O) YEL/GRY (N/C) YEL/BLK (COM) PURPLE (COM) PUR/BLK (N/O) YEL/GRY (N/C) YEL/BLK (COM) PIN 4 IM1 LT. BLU LH LIGHT SWITCH (DOOR OPEN) BOARD VIEW RH LIGHT SWITCH (DOOR OPEN) J9 J10 +5V DC 2 4 J1 1 3 +5V DC RL2 1 LH2 & RH2 LH1 4 3 1 1 RL3 BACK VIEW 7 1 1 7 6 MC1 MB1 MB2 3 3 6 3 9 9 3 1 7 7 1 MB2 4 8 8 4 1 5 5 1 2 1 1 2 J8 AMBIENT TEMP SENSOR 1 J4 1 1 J7 U2 RL4 RL7 J5 1 1 1 MC2 MC1 MC2 LATCH CATCH AT1 RL8 2 1 RL9 RH3 5 5 4 12 J6 J3 AT1, IM1, MB1, & RH1 11 RL5 RL6 9 J11 1 4 RL1 1 9 FLAPPER & SUMP HEATER LT. BLU IM2 3 2 1 LH1 TWIST ICEMAKER WATER VALVE FRONT INSIDE VIEW IM1 MULLION HEATER PIN 2 YEL J2 RH1 2 GRN/YEL SPLICE LT. BLU/BLK PIN 6 DIODE +12V DC 5 6 J5 3 4 GRN/YEL MC1 MC1 CABINET WRAPPER 1 J8 2 1 2 4 6 YEL/BLK (COM) YEL/GRY (N/C) PUR/BLK (N/O) PURPLE (COM) RH LIGHT SWITCH (DOOR OPEN) RH1 J2 3 +5V DC 1 PIN 6 INLINE CONNECTOR ABBREVIATION KEY ABBR. EXPLANATION AT1 9 PIN CONNECTION AT AIR TOWER 9 PIN CONNECTION IN FRESH IM1 FOOD ICEMAKER COMPARTMENT 6 PIN CONNECTION IN FRESH IM2 FOOD ICEMAKER COMPARTMENT 6 PIN CONNECTION AT THE LEFT LH1 DOOR UPPER HINGE 5 PIN CONNECTION AT THE LEFT LH2 DOOR UPPER HINGE 9 PIN CONNECTION IN THE MAIN MB1 BOARD HOUSING BEHIND THE TOE GRILLE 4 PIN CONNECTION IN THE MAIN MB2 BOARD HOUSING BEHIND THE TOE GRILLE 9 PIN CONNECTION IN THE MC1 MACHINE COMPARTMENT TO THE LEFT OF THE COMPRESSOR 8 PIN CONNECTION IN THE MC2 MACHINE COMPARTMENT TO THE LEFT OF THE COMPRESSOR 9 PIN CONNECTION AT THE RIGHT RH1 DOOR UPPER HINGE 5 PIN CONNECTION AT THE RIGHT RH2 DOOR UPPER HINGE 2 PIN CONNECTION AT THE RIGHT RH3 DOOR UPPER HINGE 3 4 5 6 7 J4 8 9 1 J1 2 3 VARIABLE SPEED COMPRESSOR/ INV. CONTROL SIGNAL RED/BLK BLK/WHT PIN 5 +5V DC NEUTRAL WHT/GRN LT. BLU TAN RG-5 GRY/WHT 7 8 9 J6 10 11 12 BLK LT. BLU SPLICE YEL WHT/BRN WHT/BRN WHT/BLU WHT/BLU 4 3 2 1 4 3 2 1 WHT/BRN WHT/BRN WHT/BLU WHT/BLU 4 3 2 1 WHT/BRN WHT/BRN WHT/BLU WHT/BLU LED GRY/YEL 1 FRESH FOOD SENSOR LED GRY/YEL 2 POWER LT. BLU BLK LINE FREEZER EVAPORATOR SENSOR COMPRESSOR GROUND PIN 1 REVERSIBLE 12V DISPENSER PADDLE DISPENSER LIGHT PIN 4 +12V DC 6 4 2 1 +12V DC BASE PLATE GROUND FLAPPER POSITION SWITCH 6 4 2 1 +12V DC NON-RIBBED (LINE) POWER CORD IM2 2 4 4 2 3 6 6 3 1 3 3 1 1 4 4 1 LED POWER BOARD Wire Diagram A01536801
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement