Cisco FXOS Firepower Chassis Manager Firepower Security Appliance Configuration Guide
The FXOS Firepower Chassis Manager is a web interface that makes it easy to configure platform settings and interfaces, provision devices, and monitor system status. It is part of the Cisco Application Centric Infrastructure (ACI) Security Solution, providing an agile, open, and secure platform built for scalability, consistent control, and simplified management. The Firepower Security Appliance FXOS Firepower Chassis Manager provides modular chassis-based security, a graphical user interface for configuration and monitoring, a command-line interface (FXOS CLI), and a REST API for programmatic configuration and management.
Advertisement
Advertisement
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
First Published:
2016-04-12
Last Modified:
2017-03-20
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS,
INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND,
EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH
THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY,
CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB's public domain version of the UNIX operating system. All rights reserved. Copyright
©
1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “ AS IS" WITH ALL FAULTS.
CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT
LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: http:// www.cisco.com/go/trademarks
. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)
©
2016-2017 Cisco Systems, Inc. All rights reserved.
C O N T E N T S
C H A P T E R 1
C H A P T E R 2
C H A P T E R 3
Introduction to the Firepower Security Appliance 1
About the Firepower Security Appliance
Firepower Chassis Manager Overview
Log In or Out of the Firepower Chassis Manager
About Smart Software Licensing
Smart Software Licensing for Applications on the FXOS Chassis
Smart Software Manager and Accounts
Licenses and Devices Managed per Virtual Account
Device Registration and Tokens
Periodic Communication with the License Authority
Smart Call Home Infrastructure
Prerequisites for Smart Software Licensing
Defaults for Smart Software Licensing
Configure Smart Software Licensing
(Optional) Configure the HTTP Proxy
Register the Firepower Security Appliance with the License Authority
Smart License Manager Satellite for the FXOS chassis
Configure a Smart License Satellite Server for the FXOS chassis
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1) iii
Contents
C H A P T E R 4
C H A P T E R 5
C H A P T E R 6
Configure Permanent License Reservation
(Optional) Return the FXOS Permanent License
History for Smart Software Licensing
Guidelines for Remote Authentication
Password Profile for Locally Authenticated Users
Set the Maximum Number of Login Attempts
Configure Minimum Password Length Check
Activating or Deactivating a Local User Account
Downloading Images from Cisco.com
Uploading an Image to the Firepower Security Appliance
Verifying the Integrity of an Image
Upgrading the Firepower eXtensible Operating System Platform Bundle
Updating the Image Version for a Logical Device
Security Certifications Compliance 39
Security Certifications Compliance
Configure IPSec Secure Channel
Configure Static CRL for a Trustpoint
About the Certificate Revocation List Check
iv
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Contents
C H A P T E R 7
C H A P T E R 8
Set the LDAP Key Ring Certificate
Changing the Management IP Address
Changing the Application Management IP
Modifying the Pre-Login Banner
Install a Trusted Identity Certificate
Recovering from a Software Failure
Recovering from a Corrupted File System
Viewing the Configured Date and Time
Setting the Date and Time Using NTP
Setting the Date and Time Manually
SNMP Security Levels and Privileges
Supported Combinations of SNMP Security Models and Levels
Enabling SNMP and Configuring SNMP Properties
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1) v
Contents
C H A P T E R 9
Certificates, Key Rings, and Trusted Points
Regenerating the Default Key Ring
Creating a Certificate Request for a Key Ring
Creating a Certificate Request for a Key Ring with Basic Options
Creating a Certificate Request for a Key Ring with Advanced Options
Importing a Certificate into a Key Ring
Configuring Properties for LDAP Providers
Configuring Properties for RADIUS Providers
Configuring Properties for TACACS+ Providers
About Firepower Security Appliance Interfaces
vi
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Contents
C H A P T E R 1 0
Change the Administrative State of an Interface
Create a Standalone Logical Device
Create a Standalone ASA Logical Device
Create a Standalone Threat Defense Logical Device
About Clustering on the FXOS Chassis
Primary and Secondary Unit Roles
Size the Cluster Control Link for Inter-Chassis Clustering
Cluster Control Link Redundancy for Inter-Chassis Clustering
Cluster Control Link Reliability for Inter-Chassis Clustering
Configure Firepower Threat Defense Clustering
Examples for Inter-Site Clustering
Spanned EtherChannel Transparent Mode North-South Inter-Site Example
Spanned EtherChannel Transparent Mode East-West Inter-Site Example
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1) vii
Contents
C H A P T E R 1 1
C H A P T E R 1 2
C H A P T E R 1 3
Prerequisites for Service Chaining
Guidelines for Service Chaining
Configure Radware DefensePro Service Chain on a Standalone Logical Device
Configure Radware DefensePro Service Chain on an Intra-Chassis Cluster
Open UDP/TCP Ports and Enable vDP Web Services
Connect to the Console of the Application or Decorator
Change the ASA to Transparent Firewall Mode
Change an Interface on a Firepower Threat Defense Logical Device
Change an Interface on an ASA Logical Device
Security Module/Engine Management 153
About FXOS Security Modules/Security Engine
Decommissioning/Recommissioning a Security Module
Acknowledging a Security Module/Engine
Resetting a Security Module/Engine
Reinitializing a Security Module/Engine
Powering On/Off a Security Module/Engine
About Configuration Import/Export
Exporting a Configuration File
Scheduling Automatic Configuration Export
Setting a Configuration Export Reminder
Importing a Configuration File
Creating or Editing a Packet Capture Session
Configuring Filters for Packet Capture
Starting and Stopping a Packet Capture Session
Downloading a Packet Capture File
viii
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
1
Introduction to the Firepower Security Appliance
•
About the Firepower Security Appliance, page 1
•
Firepower Chassis Manager Overview, page 1
•
Monitoring the Chassis Status, page 2
About the Firepower Security Appliance
The Cisco FXOS chassis is a next-generation platform for network and content security solutions. The FXOS chassis is part of the Cisco Application Centric Infrastructure (ACI) Security Solution and provides an agile, open, secure platform that is built for scalability, consistent control, and simplified management.
The FXOS chassis provides the following features:
• Modular chassis-based security system — provides high performance, flexible input/output configurations, and scalability.
•
Firepower Chassis Manager
— graphical user interface provides streamlined, visual representation of current chassis status and simplified configuration of chassis features.
•
FXOS CLI
— provides command-based interface for configuring features, monitoring chassis status, and accessing advanced troubleshooting features.
• FXOS REST API — allows users to programmatically configure and manage their chassis.
Firepower Chassis Manager Overview
The Firepower eXtensible Operating System provides a web interface that makes it easy to configure platform settings and interfaces, provision devices, and monitor system status. The navigation bar at the top of the user interface provides access to the following:
• Overview — From the Overview page you can easily monitor the status of the Firepower chassis. For more information, see
Monitoring the Chassis Status, on page 2
.
• Interfaces — From the Interfaces page, you can view the status of the installed interfaces on the chassis, edit interface properties, enable or disable an interface, and create port channels. For more information, see
Interface Management, on page 113
.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
1
Introduction to the Firepower Security Appliance
Monitoring the Chassis Status
• Logical Devices — From the Logical Devices page, you can create, edit, and delete logical devices. For more information, see
.
•
Security Modules/Security Engine
—
From the Security Modules/Security Engine page, you can view the status of and can perform various functions on a security module/engine, such as power cycling, reinitializing, acknowledging, and decommissioning. For more information, see
.
•
Platform Settings
—
From the Platform Settings page, you can configure chassis settings for the following: date and time, SSH, SNMP, HTTPS, AAA, Syslog, and DNS. For more information, see
.
• System Settings — From the System menu, you can manage the following settings:
◦ Licensing — From the Licensing page, you can configure Smart Call Home settings and register your Firepower chassis with the Licensing Authority. For more information, see
.
◦ Updates — From the Updates page, you can upload Platform Bundle and Application images to the
Firepower chassis. For more information, see
.
◦
User Management
—
From the User Management page you can configure user settings and define user accounts for the FXOS chassis. For more information, see
.
Monitoring the Chassis Status
From the Overview page you can easily monitor the status of the FXOS chassis. The Overview page provides the following elements:
•
Device Information
—
The top of the Overview page contains the following information about the FXOS chassis:
◦
Chassis name
— shows the name assigned to the chassis during initial configuration.
◦ IP address — shows the management IP address assigned to the chassis during initial configuration.
◦ Model — shows the FXOS chassis model.
◦
Version
— shows the version number of the FXOS running on the chassis.
◦ Operational State — shows the operable status for the chassis.
◦ Chassis uptime — shows the elapsed time since the system was last restarted.
◦
Shutdown button
— gracefully shuts down the FXOS chassis (see
Powering Off the FXOS Chassis,
on page 60 ).
Note
You can power on/off a security module/engine from the Security Modules/Security
Engine page (see
Powering On/Off a Security Module/Engine, on page 156
).
◦ Reboot button — gracefully shuts down the FXOS chassis (see
Rebooting the FXOS Chassis, on
page 59 ).
2
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Introduction to the Firepower Security Appliance
Monitoring the Chassis Status
Note
You can reset a security module/engine from the Security Modules/Security Engine page (see
Resetting a Security Module/Engine, on page 155
).
◦
Uptime Information Icon
— hover over the icon to see uptime for the chassis and for any installed security module/engine.
•
Visual Status Display
—
Below the Device Information section is a visual representation of the chassis that shows the components that are installed in the chassis and provides a general status for those components. You can hover over the ports that are shown in the Visual Status Display to get additional information such as interface name, speed, type, admin state, and operational state. For models with multiple security modules, you can hover over the security modules that are shown in the Visual Status
Display to get additional information such as device name, template type, admin state, and operational state.
•
Detailed Status Information
—
Below the Visual Status Display is a table containing detailed status information for the chassis. The status information is broken up into five sections: Faults, Interfaces,
Devices, License, and Inventory. You can see a summary for each of those sections above the table and you can see additional details for each of those sections by clicking on the summary area for the information you want to view.
The system provides the following detailed status information for the chassis:
◦ Faults — Lists the faults that have been generated in the system. The faults are sorted by severity:
Critical, Major, Minor, Warning, and Info. For each fault that is listed, you can see the severity, a description of the fault, the cause, the number of occurrences, and the time of the most recent occurrence. You can also see whether the fault has been acknowledged or not.
You can click on any of the faults to see additional details for the fault or to acknowledge the fault.
Note
Once the underlying cause of the fault has been addressed, the fault will automatically be cleared from the listing during the next polling interval. If a user is working on a resolution for a specific fault, they can acknowledge the fault to let other users know that the fault is currently being addressed.
◦
Interfaces
—
Lists the interfaces installed in the system. The
All Interfaces
tab shows the interface name, operational status, administrative status, number of received bytes, and number of transmitted bytes. The
Hardware Bypass
tab shows only interface pairs that are supported for the Hardware
Bypass feature on the Firepower Threat Defense application. For each pair, the operational state is shown: disabled (Hardware Bypass is not configured for the pair), standby (Hardware Bypass is configured, but not currently active), and bypass (actively in Hardware Bypass).
◦ Devices — Lists the logical devices configured in the system and provides the following details for each logical device: device name, device state, application template type, operational state, administrative state, image version, management IP address, and ASDM URL.
◦ License — Shows whether smart licensing is enabled, provides the current registration status of your Firepower license, and shows license authorization information for the chassis.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
3
Introduction to the Firepower Security Appliance
Monitoring the Chassis Status
◦ Inventory — Lists the components installed in the chassis and provides relevant details for those components, such as: component name, number of cores, installation location, operational status, operability, capacity, power, thermal, serial number, model number, part number, and vendor.
4
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
2
Getting Started
•
•
•
Log In or Out of the Firepower Chassis Manager, page 8
•
Accessing the FXOS CLI, page 8
Task Flow
The following procedure shows the basic tasks that should be completed when configuring your FXOS chassis.
Procedure
Step 1
Configure the FXOS chassis hardware (see the Cisco Firepower Security Appliance Hardware Installation
Guide ).
Step 2
Complete the initial configuration (see
Initial Configuration, on page 6
).
Step 3
Log in to the Firepower Chassis Manager (see
Log In or Out of the Firepower Chassis Manager, on page
8 ).
Step 4
Set the Date and Time (see
Setting the Date and Time, on page 79
).
Step 5
Configure a DNS server (see
Configuring DNS Servers, on page 111
).
Step 6
Register your product license (see
License Management, on page 11
).
Step 7
Configure users (see
).
Step 8
Perform software updates as required (see
).
Step 9
Configure additional platform settings (see
).
Step 10
Configure interfaces (see
Interface Management, on page 113
).
Step 11
Create logical devices (see
).
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
5
Getting Started
Initial Configuration
Initial Configuration
Before you can use Firepower Chassis Manager or the FXOS CLI to configure and manage your system, you must perform some initial configuration tasks using the FXOS CLI accessed through the console port. The first time that you access the FXOS chassis using the FXOS CLI, you will encounter a setup wizard that you can use to configure the system.
You can choose to either restore the system configuration from an existing backup file, or manually set up the system by going through the Setup wizard. If you choose to restore the system, the backup file must be reachable from the management network.
You must specify only one IPv4 address, gateway, and subnet mask, or only one IPv6 address, gateway, and network prefix for the single management port on the FXOS chassis. You can configure either an IPv4 or an
IPv6 address for the management port IP address.
Before You Begin
1
Verify the following physical connections on the FXOS chassis:
• The console port is physically connected to a computer terminal or console server.
• The 1 Gbps Ethernet management port is connected to an external hub, switch, or router.
For more information, refer to the Cisco Firepower Security Appliance Hardware Installation Guide .
2
Verify that the console port parameters on the computer terminal (or console server) attached to the console port are as follows:
• 9600 baud
• 8 data bits
• No parity
• 1 stop bit
Procedure
Step 1
Connect to the console port.
Step 2
Power on the FXOS chassis.
You will see the power on self-test messages as the FXOS chassis boots.
Step 3
When the unconfigured system boots, a setup wizard prompts you for the following information required to configure the system:
• Setup mode (restore from full system backup or initial setup)
• Strong password enforcement policy (for strong password guidelines, see
)
• Admin password
• System name
• Management port IPv4 address and subnet mask, or IPv6 address and prefix
6
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Getting Started
Initial Configuration
• Default gateway IPv4 or IPv6 address
• DNS Server IPv4 or IPv6 address
• Default domain name
Step 4
Review the setup summary and enter
yes
to save and apply the settings, or enter
no
to go through the Setup wizard again to change some of the settings.
If you choose to go through the Setup wizard again, the values you previously entered appear in brackets. To accept previously entered values, press
Enter
.
The following example sets up a configuration using IPv4 management addresses:
Enter the setup mode; setup newly or restore from backup. (setup/restore) ?
setup
You have chosen to setup a new Fabric interconnect. Continue? (y/n):
y
Enforce strong password? (y/n) [y]:
n
Enter the password for "admin":
adminpassword%958
Confirm the password for "admin":
adminpassword%958
Enter the system name:
foo
Physical Switch Mgmt0 IP address :
192.168.10.10
Physical Switch Mgmt0 IPv4 netmask:
255.255.255.0
IPv4 address of the default gateway:
192.168.10.1
Configure the DNS Server IP address? (yes/no) [n]:
yes
DNS IP address:
20.10.20.10
Configure the default domain name? (yes/no) [n]:
yes
Default domain name:
domainname.com
Following configurations will be applied:
Switch Fabric=A
System Name=foo
Enforce Strong Password=no
Physical Switch Mgmt0 IP Address=192.168.10.10
Physical Switch Mgmt0 IP Netmask=255.255.255.0
Default Gateway=192.168.10.1
IPv6 value=0
DNS Server=20.10.20.10
Domain Name=domainname.com
Apply and save the configuration (select 'no' if you want to re-enter)? (yes/no):
yes
The following example sets up a configuration using IPv6 management addresses:
Enter the setup mode; setup newly or restore from backup. (setup/restore) ?
setup
You have chosen to setup a new Fabric interconnect. Continue? (y/n):
y
Enforce strong password? (y/n) [y]:
n
Enter the password for "admin":
adminpassword%652
Confirm the password for "admin":
adminpassword%652
Enter the system name:
foo
Physical Switch Mgmt0 IP address :
2001::107
Physical Switch Mgmt0 IPv6 prefix:
64
IPv6 address of the default gateway:
2001::1
Configure the DNS Server IPv6 address? (yes/no) [n]:
yes
DNS IP address:
2001::101
Configure the default domain name? (yes/no) [n]:
yes
Default domain name:
domainname.com
Following configurations will be applied:
Switch Fabric=A
System Name=foo
Enforced Strong Password=no
Physical Switch Mgmt0 IPv6 Address=2001::107
Physical Switch Mgmt0 IPv6 Prefix=64
Default Gateway=2001::1
Ipv6 value=1
DNS Server=2001::101
Domain Name=domainname.com
Apply and save the configuration (select 'no' if you want to re-enter)? (yes/no):
yes
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
7
Getting Started
Log In or Out of the Firepower Chassis Manager
Log In or Out of the Firepower Chassis Manager
Note
You can optionally configure your Firepower Chassis Manager to allow only a certain number of unsuccessful login attempts before the user is locked out of the system for a specified amount of time.
This option is one of a number offered for achieving Common Criteria certification compliance on your system. For more information, see
Security Certifications Compliance, on page 39
.
Procedure
Step 1
To log in to the Firepower Chassis Manager: a) Using a supported browser, enter the following URL in the address bar: https://
<chassis_mgmt_ip_address>
where
<chassis_mgmt_ip_address>
is the IP address or host name of the FXOS chassis that you entered during initial configuration.
Note
For information on supported browsers, refer to the release notes for the version you are using
(see http://www.cisco.com/c/en/us/support/security/firepower-9000-series/ products-release-notes-list.html
).
b) Enter your username and password.
c) Click
Login
.
You are logged in and the Firepower Chassis Manager opens to show the Overview page.
Step 2
To log out of the Firepower Chassis Manager, point at your username in the navigation bar and then select
Logout
.
You are logged out of the Firepower Chassis Manager and are returned to the login screen.
Accessing the FXOS CLI
You can connect to the FXOS CLI using a terminal plugged into the console port. Verify that the console port parameters on the computer terminal (or console server) attached to the console port are as follows:
• 9600 baud
• 8 data bits
• No parity
• 1 stop bit
You can also connect to the FXOS CLI using SSH and Telnet. The Firepower eXtensible Operating System supports up to eight simultaneous SSH connections. To connect with SSH, you need to know the hostname or IP address of the FXOS chassis.
Use one of the following syntax examples to log in with SSH, Telnet, or Putty:
8
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Getting Started
Accessing the FXOS CLI
Note
SSH log in is case-sensitive.
From a Linux terminal using SSH:
• ssh ucs-auth-domain \\
username
@{
UCSM-ip-address
|
UCMS-ipv6-address
}
ssh ucs-example\\[email protected]
ssh ucs-example\\jsmith@2001::1
• ssh -l ucs-auth-domain \\
username
{
UCSM-ip-address
|
UCSM-ipv6-address
|
UCSM-host-name
}
ssh -l ucs-example\\jsmith 192.0.20.11
ssh -l ucs-example\\jsmith 2001::1
•
ssh
{
UCSM-ip-address
|
UCSM-ipv6-address
|
UCSM-host-name
} -l ucs-auth-domain \\
username
ssh 192.0.20.11 -l ucs-example\\jsmith ssh 2001::1 -l ucs-example\\jsmith
• ssh ucs-auth-domain \\
username
@{
UCSM-ip-address
|
UCSM-ipv6-address
}
ssh ucs-ldap23\\[email protected]
ssh ucs-ldap23\\jsmith@2001::1
From a Linux terminal using Telnet:
Note
Telnet is disabled by default. See
Configuring Telnet, on page 82
for instructions on enabling Telnet.
• telnet ucs-UCSM-host-name ucs-auth-domain \
username
telnet ucs-qa-10
login:
ucs-ldap23\blradmin
•
telnet ucs-
{
UCSM-ip-address
|
UCSM-ipv6-address
}
ucs-auth-domain
\
username
telnet 10.106.19.12 2052
ucs-qa-10-A login:
ucs-ldap23\blradmin
From a Putty client:
• Login as: ucs-auth-domain \
username
Login as:
ucs-example\jsmith
Note
If the default authentication is set to local, and the console authentication is set to LDAP, you can log in to the fabric interconnect from a Putty client using ucs-local\admin, where admin is the name of the local account.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
9
Accessing the FXOS CLI
Getting Started
10
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
3
License Management
Cisco Smart Software Licensing lets you purchase and manage a pool of licenses centrally. You can easily deploy or retire devices without having to manage each unit
’ s license key. Smart Software Licensing also lets you see your license usage and needs at a glance.
•
About Smart Software Licensing, page 11
•
Prerequisites for Smart Software Licensing, page 13
•
Defaults for Smart Software Licensing, page 14
•
Configure Smart Software Licensing, page 14
•
Smart License Manager Satellite for the FXOS chassis, page 15
•
Permanent License Reservation, page 16
•
History for Smart Software Licensing, page 18
About Smart Software Licensing
This section describes how Smart Software Licensing works.
Note
This section only applies to ASA logical devices on the FXOS chassis. For more information on licensing for Firepower Threat Defense logical devices, see the Firepower Management Center Configuration Guide.
Smart Software Licensing for Applications on the FXOS Chassis
For the application on the FXOS chassis, Smart Software Licensing configuration is split between the FXOS chassis supervisor and the application.
•
FXOS chassis
—
Configure all Smart Software Licensing infrastructure in the supervisor, including parameters for communicating with the License Authority. The FXOS chassis itself does not require any licenses to operate.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
11
License Management
Smart Software Manager and Accounts
For offline licensing, you can deploy a Cisco Smart Software Manager satellite server that is accessible to your local network, and that syncs with the License Authority on demand or on a schedule you set.
The three Smart License models supported on the FXOS chassis are Smart License default mode, Proxy mode, and Smart License Satellite mode. Inter-chassis clustering requires that you enable the same Smart
Licensing mode type on each FXOS chassis in the cluster.
•
Application
—
Configure all license entitlements in the application.
Smart Software Manager and Accounts
When you purchase 1 or more licenses for the device, you manage them in the Cisco Smart Software Manager: https://software.cisco.com/#module/SmartLicensing
The Smart Software Manager lets you create a master account for your organization.
Note
If you do not yet have an account, click the link to set up a new account . The Smart Software Manager lets you create a master account for your organization.
By default, your licenses are assigned to the
Default Virtual Account
under your master account. As the account administrator, you can optionally create additional virtual accounts; for example, you can create accounts for regions, departments, or subsidiaries. Multiple virtual accounts let you more easily manage large numbers of licenses and devices.
Licenses and Devices Managed per Virtual Account
Licenses and devices are managed per virtual account: only that virtual account
’ s devices can use the licenses assigned to the account. If you need additional licenses, you can transfer an unused license from another virtual account. You can also transfer devices between virtual accounts.
Only the FXOS chassis registers as a device, while the applications in the chassis request their own licenses.
For example, for a Firepower 9300 chassis with 3 security modules, the chassis counts as one device, but the modules use 3 separate licenses.
Device Registration and Tokens
For each virtual account, you can create a registration token. This token is valid for 30 days by default. Enter this token ID plus entitlement levels when you deploy each device, or when you register an existing device.
You can create a new token if an existing token is expired.
Note
Device registration is configured in the FXOS chassis supervisor, not on the security module.
At startup after deployment, or after you manually configure these parameters on an existing device, the device registers with the Cisco License Authority. When the device registers with the token, the License Authority issues an ID certificate for communication between the device and the License Authority. This certificate is valid for 1 year, although it will be renewed every 6 months.
12
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
License Management
Periodic Communication with the License Authority
Periodic Communication with the License Authority
The device communicates with the License Authority every 30 days. If you make changes in the Smart Software
Manager, you can refresh the authorization on the device so the change takes place immediately. Or you can wait for the device to communicate as scheduled.
You can optionally configure an HTTP proxy.
The FXOS chassis must have Internet access either directly or through an HTTP proxy at least every 90 days.
Normal license communication occurs every 30 days, but with the grace period, your device will operate for up to 90 days without calling home. After the grace period, you must contact the Licensing Authority, or you will not be able to make configuration changes to features requiring special licenses; operation is otherwise unaffected.
Note
Offline licensing is not supported.
Out-of-Compliance State
The device can become out of compliance in the following situations:
• Over-utilization — When the device uses unavailable licenses.
•
License expiration
—
When a time-based license expires.
•
Lack of communication
—
When the device cannot reach the Licensing Authority for re-authorization.
To verify whether your account is in, or approaching, an Out-of-Compliance state, you must compare the entitlements currently in use by your FXOS chassis against those in your Smart Account.
In an out-of-compliance state, the device will be limited in some way, depending on the application.
Smart Call Home Infrastructure
By default, a Smart Call Home profile exists in the configuration that specifies the URL for the Licensing
Authority. You cannot remove this profile. Note that the only configurable option for the License profile is the destination address URL for the License Authority. Unless directed by Cisco TAC, you should not change the License Authority URL.
You cannot disable Smart Call Home for Smart Software Licensing.
Prerequisites for Smart Software Licensing
• Create a master account on the Cisco Smart Software Manager: https://software.cisco.com/#module/SmartLicensing
If you do not yet have an account, click the link to set up a new account . The Smart Software Manager lets you create a master account for your organization.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
13
License Management
Defaults for Smart Software Licensing
• Purchase 1 or more licenses from Cisco Software Central.
• Ensure Internet access or HTTP proxy access from the device, so the device can contact the Licensing
Authority. Offline licensing is not supported.
• Configure a DNS server so the device can resolve the name of the licensing authority server.
• Set the clock for the device.
• Note that this section only applies to ASA logical devices on the FXOS chassis. For more information on licensing for Firepower Threat Defense logical devices, see the Firepower Management Center
Configuration Guide.
Defaults for Smart Software Licensing
The FXOS chassis default configuration includes a Smart Call Home profile called “ SLProf ” that specifies the URL for the Licensing Authority.
Configure Smart Software Licensing
To communicate with the Cisco License Authority, you can optionally configure an HTTP proxy. To register with the License Authority, you must enter the registration token ID on the FXOS chassis that you obtained from your Smart Software License account.
Procedure
Step 1
(Optional) Configure the HTTP Proxy, on page 14
.
Step 2
Register the Firepower Security Appliance with the License Authority, on page 15
.
(Optional) Configure the HTTP Proxy
If your network uses an HTTP proxy for Internet access, you must configure the proxy address for Smart
Software Licensing. This proxy is also used for Smart Call Home in general.
Note
HTTP proxy with authentication is not supported.
Procedure
Step 1
Choose
System
>
Licensing
>
Call Home
.
The Call Home page provides fields for configuring the destination address URL for the License Authority and for configuring an HTTP proxy.
Note
Unless directed by Cisco TAC, you should not change the License Authority
URL.
14
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
License Management
Register the Firepower Security Appliance with the License Authority
Step 2
In the Server Enable drop-down list, select
on
.
Step 3
Enter the proxy IP address and port in the
Server URL
and
Server Port
fields. For example, enter port 443 for an HTTPS server.
Step 4
Click
Save
.
Register the Firepower Security Appliance with the License Authority
When you register the FXOS chassis, the License Authority issues an ID certificate for communication between the FXOS chassis and the License Authority. It also assigns the FXOS chassis to the appropriate virtual account. Normally, this procedure is a one-time instance. However, you might need to later re-register the
FXOS chassis if the ID certificate expires because of a communication problem, for example.
Procedure
Step 1
In the Smart Software Manager, request and copy a registration token for the virtual account to which you want to add this FXOS chassis.
Step 2
In Firepower Chassis Manager, choose
System
>
Licensing
>
Smart License
.
Step 3
Enter the registration token in the
Enter Product Instance Registration Token
field.
Step 4
Click
Register
.
The FXOS chassis attempts to register with the License Authority.
To unregister the device, click
Unregister
.
Deregistering the FXOS chassis removes the device from your account. All license entitlements and certificates on the device are removed. You might want to deregister to free up a license for a new FXOS chassis.
Alternatively, you can remove the device from the Smart Software Manager.
Smart License Manager Satellite for the FXOS chassis
Cisco Smart Software Manager satellite is a component of Cisco Smart Licensing that works in conjunction with Cisco Smart Software Manager (SSM) . It helps you intelligently manage customer product licenses, providing near real-time visibility and reporting of Cisco licenses that customers purchase and consume.
Customers who, either for policy or network reachability reasons, do not want to manage their Cisco products directly using the Cisco Smart Software Manager residing at software.cisco.com, can choose to install the
Cisco Smart Software Manager satellite on-premises. When enabled, the FXOS chassis sends report license consumption to the Smart Software Manager satellite as though it were a replicate of the Cisco Smart Software
Manager hosted within your premises.
Once you download and deploy the satellite application, you can perform the following functions without sending data to Cisco SSM using the Internet:
• Activate or register a license
• View your company's licenses
• Transfer licenses between company entities
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
15
License Management
Configure a Smart License Satellite Server for the FXOS chassis
For more information, see the Smart Software Manager satellite installation and configuration guides on Smart
Account Manager satellite .
Configure a Smart License Satellite Server for the FXOS chassis
The following procedure shows how to configure the FXOS chassis to use a Smart Licence Manager satellite.
Before You Begin
• Complete all prerequisites listed in the
Prerequisites for Smart Software Licensing, on page 13
.
• Download the Smart License Satellite OVA file from Cisco.com and install and configure it on a
VMwareESXi server. For more information, see the Smart Software Manager satellite Install Guide .
Procedure
Step 1
Choose
System
>
Licensing
>
Call Home
.
Step 2
Under Call home Configuration, replace the default URL in the Address field with the satellite URL.
Step 3
Create a new trust point using the CLI. (See the Smart License Satellite manager configuration steps in the
FXOS CLI Configuration Guide for more information).
Step 4
Register the Firepower Security Appliance with the License Authority, on page 15
. Note that you must request and copy the registration token from the Smart License Manager satellite.
Permanent License Reservation
You can assign a permanent license to your FXOS chassis. This universal reservation allows you to use any entitlement for an unlimited count on your device.
Note
Before you begin, you must purchase the permanent licenses so they are available in the Smart Software
Manager. Not all accounts are approved for permanent license reservation. Make sure you have approval from Cisco for this feature before you attempt to configure it.
Configure Permanent License Reservation
The following procedure shows how to assign a permanent license to your FXOS chassis.
16
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
License Management
(Optional) Return the FXOS Permanent License
Procedure
Step 1
Choose
System
>
Licensing
>
Permanent License
.
Step 2
Click
Generate
to generate a reservation request code. Copy the reservation request code to your clipboard.
Step 3
Go to the Smart Software Manager Inventory screen in the Cisco Smart Software Manager portal, and click the
Licenses
tab: https://software.cisco.com/#SmartLicensing-Inventory
The
Licenses
tab displays all existing licenses related to your account, both regular and permanent.
Step 4
Click
License Reservation
, and paste the generated reservation request code into the box.
Step 5
Click
Reserve License
.
The Smart Software Manager generates an authorization code. You can download the code or copy it to the clipboard. At this point, the license is now in use according to the Smart Software Manager.
If you do not see the
License Reservation
button, then your account is not authorized for permanenet license reservation. In this case, you should disable permanent license reservation and re-enter the regular smart license commands.
Step 6
In the FXOS chassis supervisor, enter the generated authorization code into the
Authorization Code
text box.
Step 7
Click
Install
.
Once your FXOS chassis is fully licensed with PLR, the Permanenet License page displays your license status and offers the option to return your permanent license.
(Optional) Return the FXOS Permanent License
If you no longer need a permanent license, you must officially return it to the Smart Software Manager using this procedure. If you do not follow all steps, the license stays in an in-use state and cannot be used elsewhere.
Procedure
Step 1
Choose
System
>
Licensing
>
Permanent License
.
Step 2
Click
Return
to generate a return code. Copy the return code to your clipboard.
The FXOS chassis immediately becomes unlicensed and moves to the Evaluation state.
Step 3
Go to the Smart Software Manager Inventory screen, and click on the
Product Instances
tab: https://software.cisco.com/#SmartLicensing-Inventory
Step 4
Search for your FXOS chassis using its universal device identifier (UDI).
Step 5
Choose
Actions
>
Remove
, and paste the generated return code into the box.
Step 6
Click
Remove Product Instance
.
The permanent license is returned to the available pool.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
17
License Management
History for Smart Software Licensing
History for Smart Software Licensing
Feature Name Description
Cisco Smart Software Licensing for the FXOS chassis
Platform
Releases
1.1(1) Smart Software Licensing lets you purchase and manage a pool of licenses. Smart licenses are not tied to a specific serial number. You can easily deploy or retire devices without having to manage each unit
’ s license key. Smart Software Licensing also lets you see your license usage and needs at a glance. Smart
Software Licensing configuration is split between the FXOS chassis supervisor and the security module.
We introduced the following screens:
System
>
Licensing
>
Call Home
System
>
Licensing
>
Smart License
18
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
4
User Management
•
•
Guidelines for Usernames, page 20
•
Guidelines for Passwords, page 21
•
Guidelines for Remote Authentication, page 21
•
•
Password Profile for Locally Authenticated Users, page 24
•
Configuring User Settings, page 25
•
Set the Maximum Number of Login Attempts, page 27
•
Configure Minimum Password Length Check, page 28
•
Creating a Local User Account, page 29
•
Deleting a Local User Account, page 30
•
Activating or Deactivating a Local User Account, page 30
User Accounts
User accounts are used to access the system. You can configure up to 48 local user accounts. Each user account must have a unique username and password.
Admin Account
The admin account is a default user account and cannot be modified or deleted. This account is the system administrator or superuser account and has full privileges. There is no default password assigned to the admin account; you must choose the password during the initial system setup.
The admin account is always active and does not expire. You cannot configure the admin account as inactive.
Locally Authenticated User Accounts
A locally authenticated user account is authenticated directly through the chassis and can be enabled or disabled by anyone with admin or AAA privileges. Once a local user account is disabled, the user cannot log in.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
19
User Management
Guidelines for Usernames
Configuration details for disabled local user accounts are not deleted by the database. If you reenable a disabled local user account, the account becomes active again with the existing configuration, including username and password.
Remotely Authenticated User Accounts
A remotely authenticated user account is any user account that is authenticated through LDAP, RADIUS, or
TACACS+.
If a user maintains a local user account and a remote user account simultaneously, the roles defined in the local user account override those maintained in the remote user account.
See the following topics for more information on guidelines for remote authentication, and how to configure and delete remote authentication providers:
•
Guidelines for Remote Authentication, on page 21
•
Configuring LDAP Providers, on page 101
•
Configuring RADIUS Providers, on page 104
•
Configuring TACACS+ Providers, on page 106
Expiration of User Accounts
You can configure user accounts to expire at a predefined time. When the expiration time is reached, the user account is disabled.
By default, user accounts do not expire.
After you configure a user account with an expiration date, you cannot reconfigure the account to not expire.
You can, however, configure the account with the latest expiration date available.
Guidelines for Usernames
The username is also used as the login ID for Firepower Chassis Manager and the FXOS CLI. When you assign login IDs to user accounts, consider the following guidelines and restrictions:
• The login ID can contain between 1 and 32 characters, including the following:
◦ Any alphabetic character
◦ Any digit
◦ _ (underscore)
◦ - (dash)
◦ . (dot)
• The login ID must be unique.
• The login ID must start with an alphabetic character. It cannot start with a number or a special character, such as an underscore.
• The login ID is case-sensitive.
• You cannot create an all-numeric login ID.
20
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
User Management
Guidelines for Passwords
• After you create a user account, you cannot change the login ID. You must delete the user account and create a new one.
Guidelines for Passwords
A password is required for each locally authenticated user account. A user with admin or AAA privileges can configure the system to perform a password strength check on user passwords. If the password strength check is enabled, each user must have a strong password.
We recommend that each user have a strong password. If you enable the password strength check for locally authenticated users, the Firepower eXtensible Operating System rejects any password that does not meet the following requirements:
• Must contain a minimum of 8 characters and a maximum of 80 characters.
Note
You can optionally configure a minimum password length of 15 characters on the system, to comply with Common Criteria requirements. For more information, see
Minimum Password Length Check, on page 28
.
• Must include at least one uppercase alphabetic character.
• Must include at least one lowercase alphabetic character.
• Must include at least one non-alphanumeric (special) character.
• Must not contain a character that is repeated more than 3 times consecutively, such as aaabbb.
• Must not contain three consecutive numbers or letters in any order, such as passwordABC or password321.
• Must not be identical to the username or the reverse of the username.
• Must pass a password dictionary check. For example, the password must not be based on a standard dictionary word.
• Must not contain the following symbols: $ (dollar sign), ? (question mark), and = (equals sign).
• Must not be blank for local user and admin accounts.
Guidelines for Remote Authentication
If a system is configured for one of the supported remote authentication services, you must create a provider for that service to ensure that the FXOS chassis can communicate with the system. The following guidelines impact user authorization:
User Accounts in Remote Authentication Services
User accounts can exist locally in the FXOS chassis or in the remote authentication server.
You can view the temporary sessions for users who log in through remote authentication services from the FXOS Chassis Manager GUI and from the FXOS CLI.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
21
User Management
Guidelines for Remote Authentication
User Roles in Remote Authentication Services
If you create user accounts in the remote authentication server, you must ensure that the accounts include the roles those users require for working in the FXOS chassis and that the names of those roles match the names used in FXOS. Based on the role policy, a user might not be allowed to log in, or is granted only read-only privileges.
User Attributes in Remote Authentication Providers
For RADIUS and TACAS+ configurations, you must configure a user attribute for the FXOS chassis in each remote authentication provider through which users log in to Firepower Chassis Manager and the FXOS CLI.
This user attribute holds the roles and locales assigned to each user.
When a user logs in, FXOS does the following:
1
Queries the remote authentication service.
2
Validates the user.
3
If the user is validated, checks the roles and locales assigned to that user.
The following table contains a comparison of the user attribute requirements for the remote authentication providers supported by FXOS:
Authenication Provider
LDAP
Custom Attribute
Optional
Schema Extension Attribute ID Requirements
You can choose to do one of the following:
The Cisco LDAP implementation requires a unicode type attribute.
• Do not extend the
LDAP schema and configure an existing, unused attribute that meets the requirements.
If you choose to create the
CiscoAVPair custom attribute, use the following attribute ID:
1.3.6.1.4.1.9.287247.1
A sample OID is provided in the following section.
• Extend the LDAP schema and create a custom attribute with a unique name, such as
CiscoAVPair.
22
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
User Management
Guidelines for Remote Authentication
Authenication Provider
RADIUS
TACAS
Custom Attribute
Optional
Required
Schema Extension Attribute ID Requirements
You can choose to do one of the following:
•
• Do not extend the
RADIUS schema and use an existing, unused attribute that meets the requirements.
Extend the
RADIUS schema and create a custom attribute with a unique name, such as cisco-avpair.
The vendor ID for the
Cisco RADIUS implementation is 009 and the vendor ID for the attribute is 001.
The following syntax example shows how to specify multiples user roles and locales if you choose to create the cisco-avpair attribute: shell:roles="admin,aaa" shell:locales="L1,abc"
.
Use a comma "," as the delimiter to separate multiple values.
You must extend the schema and create a custom attribute with the name cisco-av-pair.
The cisco-av-pair name is the string that provides the attribute ID for the
TACACS+ provider.
The following syntax example shows how to specify multiples user roles and locales when you create the cisco-av-pair attribute: cisco-av-pair=shell:roles="admin aaa" shell:locales*"L1 abc"
. Using an asterisk
(*) in the cisco-av-pair attribute syntax flags the locale as optional, preventing authentication failures for other Cisco devices that use the same authorization profile. Use a space as the delimiter to separate multiple values.
Sample OID for LDAP User Attribute
The following is a sample OID for a custom CiscoAVPair attribute:
CN=CiscoAVPair,CN=Schema,
CN=Configuration,CN=X
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
23
User Management
User Roles
objectClass: top objectClass: attributeSchema cn: CiscoAVPair distinguishedName: CN=CiscoAVPair,CN=Schema,CN=Configuration,CN=X instanceType: 0x4 uSNCreated: 26318654 attributeID: 1.3.6.1.4.1.9.287247.1
attributeSyntax: 2.5.5.12
isSingleValued: TRUE showInAdvancedViewOnly: TRUE adminDisplayName: CiscoAVPair adminDescription: UCS User Authorization Field oMSyntax: 64 lDAPDisplayName: CiscoAVPair name: CiscoAVPair objectCategory: CN=Attribute-Schema,CN=Schema,CN=Configuration,CN=X
User Roles
The system contains the following user roles:
Administrator
Complete read-and-write access to the entire system. The default admin account is assigned this role by default and it cannot be changed.
Read-Only
Read-only access to system configuration with no privileges to modify the system state.
Operations
Read-and-write access to NTP configuration, Smart Call Home configuration for Smart Licensing, and system logs, including syslog servers and faults. Read access to the rest of the system.
AAA Administrator
Read-and-write access to users, roles, and AAA configuration. Read access to the rest of the system.
Password Profile for Locally Authenticated Users
The password profile contains the password history and password change interval properties for all locally authenticated users. You cannot specify a different password profile for each locally authenticated user.
Password History Count
The password history count allows you to prevent locally authenticated users from reusing the same password over and over again. When this property is configured, the Firepower chassis stores passwords that were previously used by locally authenticated users up to a maximum of 15 passwords. The passwords are stored in reverse chronological order with the most recent password first to ensure that the only the oldest password can be reused when the history count threshold is reached.
24
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
User Management
Configuring User Settings
A user must create and use the number of passwords configured in the password history count before being able to reuse one. For example, if you set the password history count to 8, a locally authenticated user cannot reuse the first password until after the ninth password has expired.
By default, the password history is set to 0. This value disables the history count and allows users to reuse previously passwords at any time.
If necessary, you can clear the password history count for a locally authenticated user and enable reuse of previous passwords.
Password Change Interval
The password change interval enables you to restrict the number of password changes a locally authenticated user can make within a given number of hours. The following table describes the two configuration options for the password change interval.
Interval Configuration
No password change allowed
Description
This option does not allow passwords for locally authenticated users to be changed within a specified number of hours after a password change.
You can specify a no change interval between 1 and 745 hours. By default, the no change interval is 24 hours.
Example
For example, to prevent passwords from being changed within 48 hours after a locally authenticated user changes his or her password, set the following:
• Change during interval to disable
• No change interval to 48
Password changes allowed within change interval
This option specifies the maximum number of times that passwords for locally authenticated users can be changed within a pre-defined interval.
You can specify a change interval between 1 and 745 hours and a maximum number of password changes between 0 and 10. By default, a locally authenticated user is permitted a maximum of 2 password changes within a 48 hour interval.
For example, to allow a password to be changed a maximum of once within 24 hours after a locally authenticated user changes his or her password, set the following:
•
•
• Change during interval to enable
Change count to 1
Change interval to 24
Configuring User Settings
Procedure
Step 1
Choose
System
>
User Management
.
Step 2
Click the
Settings
tab.
Step 3
Complete the following fields with the required information:
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
25
User Management
Configuring User Settings
Name
Default Authentication
field
Description
The default method by which a user is authenticated during remote login. This can be one of the following:
•
Local
— The user account must be defined locally on the Firepower chassis.
•
Radius
—
The user account must be defined on the RADIUS server specified for the Firepower chassis.
•
TACACS
— The user account must be defined on the TACACS+ server specified for the Firepower chassis.
•
LDAP
— The user account must be defined on the LDAP/MS-AD server specified for the Firepower chassis.
•
None
—
If the user account is local to the Firepower chassis, no password is required when the user logs in remotely.
Remote User Settings
Remote User Role Policy Controls what happens when a user attempts to log in and the remote authentication provider does not supply a user role with the authentication information:
•
Assign Default Role
— The user is allowed to log in with a read-only user role.
•
No-Login
— The user is not allowed to log in to the system, even if the username and password are correct.
Local User Settings
Password Strength Check
check box
If checked, all local user passwords must conform to the guidelines for a strong password (see
Guidelines for Passwords, on page 21
).
History Count
field The number of unique passwords a user must create before the user can reuse a previously used password. The history count is in reverse chronological order with the most recent password first to ensure that only the oldest password can be reused when the history count threshold is reached.
This value can be anywhere from 0 to 15.
You can set the
History Count
field to 0 to disable the history count and allow users to reuse previously used passwords at any time.
26
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
User Management
Set the Maximum Number of Login Attempts
Name
Change During Interval
field
Description
Controls when a locally authenticated user can change his or her password. This can be:
•
Enable
— Locally authenticated users can change their passwords based on the settings for Change Interval and Change Count.
•
Disable
—
Locally authenticated users cannot change their passwords for the period of time specified for No Change Interval.
Change Interval
field
Change Count
field
No Change Interval
field
The number of hours over which the number of password changes specified in the
Change Count
field are enforced.
This value can be anywhere from 1 to 745 hours.
For example, if this field is set to 48 and the
Change Count
field is set to 2, a locally authenticated user can make no more than 2 password changes within a 48 hour period.
The maximum number of times a locally authenticated user can change his or her password during the Change Interval.
This value can be anywhere from 0 to 10.
The minimum number of hours that a locally authenticated user must wait before changing a newly created password.
This value can be anywhere from 1 to 745 hours.
This interval is ignored if the
Change During Interval
property is not set to
Disable
.
Step 4
Click
Save
.
Set the Maximum Number of Login Attempts
You can configure the maximum number of failed login attempts allowed before a user is locked out of the
FXOS chassis for a specified amount of time. If a user exceeds the set maximum number of login attempts, the user is locked out of the system. No notification appears indicating that the user is locked out. In this event, the user must wait the specified amount of time before attempting to log in.
Perform these steps to configure the maximum number of login attempts.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
27
User Management
Configure Minimum Password Length Check
Note
• All types of user accounts (including admin) are locked out of the system after exceeding the maximum number of login attempts.
• The default maximum number of unsuccessful login attempts is 3. The default amount of time the user is locked out of the system after exceeding the maximum number of login attemps is 30 minutes
(3600 seconds).
This option is one of a number offered for achieving Common Criteria certification compliance on your system. For more information, see
Security Certifications Compliance, on page 39
.
Procedure
Step 1
From the FXOS CLI, enter security mode:
scope system scope security
Step 2
Set the maximum number of unsuccessful login attempts.
set max-login-attempts
max_login
The
max_login
value is any integer from 0-10.
Step 3
Specify the amount of time (in seconds) the user should remain locked out of the system after reaching the maximum number of login attempts:
set user-account-unlock-time
unlock_time
Step 4
Commit the configuration:
commit-buffer
Configure Minimum Password Length Check
If you enable minimum password length check, you must create passwords with the specified minimum number of characters. For example, if the
min_length
option is set to 15, you must create passwords using 15 characters or more. This option is one of a number that allow for Common Criteria certification compliance on your system. For more information, see
Security Certifications Compliance, on page 39
.
Perform these steps to configure the minimum password length check.
Procedure
Step 1
From the FXOS CLI, enter security mode:
Step 2 scope system scope security
28
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
User Management
Creating a Local User Account
Step 3
Enter password profile security mode:
scope password-profile
Step 4
Specify the minimum password length:
set min-password-length min_length
Step 5
Commit the configuration:
commit-buffer
Creating a Local User Account
Procedure
Step 1
Choose
System
>
User Management
.
Step 2
Click the
Local Users
tab.
Step 3
Click
Add User
to open the
Add User
dialog box.
Step 4
Complete the following fields with the required information about the user:
Name Description
User Name
field The account name that is used when logging into this account. This name must be unique and meet the guidelines and restrictions for user account names (see
Guidelines for Usernames, on page 20
).
After you save the user, the login ID cannot be changed. You must delete the user account and create a new one.
First Name
field The first name of the user. This field can contain up to 32 characters.
Last Name
field field
Phone Number
field
The last name of the user. This field can contain up to 32 characters.
The email address for the user.
The telephone number for the user.
Password
field
Confirm Password
Account Status
field field
The password associated with this account. If password strength check is enabled, a user's password must be strong and the Firepower eXtensible Operating System rejects any password that does not meet the strength check requirements (see
Guidelines for Passwords, on page
21 ).
The password a second time for confirmation purposes.
If the status is set to
Active
, a user can log into Firepower Chassis
Manager and the FXOS CLI with this login ID and password.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
29
User Management
Deleting a Local User Account
Name
User Role
list
Account Expires
check box
Expiry Date
field
Description
The role that represents the privileges you want to assign to the user account (see
).
All users are assigned the Read-Only role by default and this role cannot be deselected. To assign multiple roles, hold down Ctrl and click the desired roles.
Note
Changes in user roles and privileges do not take effect until the next time the user logs in. If a user is logged in when you assign a new role to or remove an existing role from a user account, the active session continues with the previous roles and privileges.
If checked, this account expires and cannot be used after the date specified in the
Expiration Date
field.
Note
After you configure a user account with an expiration date, you cannot reconfigure the account to not expire. You can, however, configure the account with the latest expiration date available.
The date on which the account expires. The date should be in the format yyyy-mm-dd.
Click the calendar icon at the end of this field to view a calendar that you can use to select the expiration date.
Step 5
Click
Add
.
Deleting a Local User Account
Procedure
Step 1
Choose
System
>
User Management
.
Step 2
Click the
Local Users
tab.
Step 3
In the row for the user account that you want to delete, click
Delete
.
Step 4
In the
Confirm
dialog box, click
Yes
.
Activating or Deactivating a Local User Account
You must be a user with admin or AAA privileges to activate or deactivate a local user account.
30
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
User Management
Activating or Deactivating a Local User Account
Procedure
Step 1
Choose
System
>
User Management
.
Step 2
Click the
Local Users
tab.
Step 3
In the row for the user account that you want to activate or deactivate, click
Edit (pencil icon)
.
Step 4
In the
Edit User
dialog box, do one of the following:
• To activate a user account, click the
Active
radio button in the
Account Status
field.
• To deactivate a user account, click the
Inactive
radio button in the
Account Status
field.
The admin user account is always set to active. It cannot be modified.
Step 5
Click
Save
.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
31
Activating or Deactivating a Local User Account
User Management
32
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
5
Image Management
•
About Image Management, page 33
•
Downloading Images from Cisco.com, page 34
•
Uploading an Image to the Firepower Security Appliance, page 34
•
Verifying the Integrity of an Image, page 34
•
Upgrading the Firepower eXtensible Operating System Platform Bundle, page 35
•
Updating the Image Version for a Logical Device, page 36
•
About Image Management
The FXOS chassis uses two basic types of images:
Note
All images are digitally signed and validated through Secure Boot. Do not modify the image in any way or you will receive a validation error.
• Platform Bundle — The Firepower platform bundle is a collection of multiple independent images that operate on the Firepower Supervisor and Firepower security module/engine. The platform bundle is a
Firepower eXtensible Operating System software package.
•
Application
—
Application images are the software images you want to deploy on the security module/engine of the FXOS chassis. Application images are delivered as Cisco Secure Package files
(CSP) and are stored on the supervisor until deployed to a security module/engine as part of logical device creation or in preparation for later logical device creation. You can have multiple different versions of the same application image type stored on the Firepower Supervisor.
Note
If you are upgrading both the Platform Bundle image and one or more Application images, you must upgrade the Platform Bundle first.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
33
Image Management
Downloading Images from Cisco.com
Downloading Images from Cisco.com
Before You Begin
You must have a Cisco.com account.
Procedure
Step 1
Choose
System
>
Updates
.
The Available Updates page shows a list of the FXOS platform bundle images and application images that are available on the chassis.
Step 2
Click the
Download latest updates from CCO
link at the bottom of the page.
The software download page for the FXOS chassis is opened in a new tab within the browser.
Step 3
Find and then download the appropriate software image to your local computer.
Uploading an Image to the Firepower Security Appliance
Before You Begin
Make sure the image you want to upload is available on your local computer.
Procedure
Step 1
Choose
System
>
Updates
.
The Available Updates page shows a list of the Firepower eXtensible Operating System platform bundle images and application images that are available on the chassis.
Step 2
Click
Upload Image
to open the Upload Image dialog box.
Step 3
Click
Browse
to navigate to and select the image that you want to upload.
Step 4
Click
Upload
.
The selected image is uploaded to the FXOS chassis.
Step 5
For certain software images you will be presented with an end-user license agreement after uploading the image. Follow the system prompts to accept the end-user license agreement.
Verifying the Integrity of an Image
The integrity of the image is automatically verified when a new image is added to the FXOS chassis. If needed, you can use the following procedure to manually verify the integrity of an image.
34
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Image Management
Upgrading the Firepower eXtensible Operating System Platform Bundle
Procedure
Step 1
Choose
System
>
Updates
.
The Available Updates page shows a list of the Firepower eXtensible Operating System platform bundle images and application images that are available on the chassis.
Step 2
Click
Verify
(check mark icon) for the image you want to verify.
The system will verify the integrity of the image and display the staus in the Image Integrity field.
Upgrading the Firepower eXtensible Operating System Platform
Bundle
Before You Begin
Download the platform bundle software image from Cisco.com (see
Downloading Images from Cisco.com,
on page 34 ) and then upload that image to the FXOS chassis (see
Uploading an Image to the Firepower
Security Appliance, on page 34
).
Note
The upgrade process typically takes between 20 and 30 minutes.
If you are upgrading a Firepower 9300 or Firepower 4100 Series security appliance that is running a standalone logical device or if you are upgrading a Firepower 9300 security appliance that is running an intra-chassis cluster, traffic will not traverse through the device while it is upgrading.
If you are upgrading Firepower 9300 or a Firepower 4100 Series security appliance that is part of an inter-chassis cluster, traffic will not traverse through the device being upgraded while it is upgrading.
However, the other devices in the cluster will continue to pass traffic.
Procedure
Step 1
Choose
System
>
Updates
.
The Available Updates page shows a list of the Firepower eXtensible Operating System platform bundle images and application images that are available on the chassis.
Step 2
Click
Upgrade
for the FXOS platform bundle to which you want to upgrade.
The system will first verify the software package that you want to install. It will inform you of any incompatibility between currently installed applications and the specified FXOS platform software package.
It will also warn you that any existing sessions will be terminated and that the system will need to be rebooted as part of the upgrade.
Step 3
Click
Yes
to confirm that you want to proceed with installation, or click
No
to cancel the installation.
The Firepower eXtensible Operating System unpacks the bundle and upgrades/reloads the components.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
35
Image Management
Updating the Image Version for a Logical Device
Updating the Image Version for a Logical Device
Before You Begin
Note
After initial creation of a Firepower Threat Defense logical device, you do not upgrade the Firepower
Threat Defense logical device using Firepower Chassis Manager or the FXOS CLI. To upgrade a Firepower
Threat Defense logical device, you must use Firepower Management Center. See the Firepower System
Release Notes for more information: http://www.cisco.com/c/en/us/support/security/defense-center/ products-release-notes-list.html
.
Also, note that any updates to the Firepower Threat Defense logical device will not be reflected on the
Logical Devices
>
Edit
and
System
>
Updates
pages in Firepower Chassis Manager. On these pages, the version shown indicates the software version (CSP image) that was used to create the Firepower Threat
Defense logical device.
Download the application image you want to use for the logical device from Cisco.com (see
Images from Cisco.com, on page 34
) and then upload that image to the FXOS chassis (see
Image to the Firepower Security Appliance, on page 34
).
If you are upgrading both the Platform Bundle image and one or more Application images, you must upgrade the Platform Bundle first.
Procedure
Step 1
Choose
Logical Devices
to open the Logical Devices page.
The Logical Devices page shows a list of configured logical devices on the chassis. If no logical devices have been configured, a message stating so is shown instead.
Step 2
Click
Update Version
for the logical device that you want to update to open the
Update Image Version
dialog box.
Step 3
For the
New Version
, choose the software version to which you want to update.
Step 4
Click
OK
.
Firmware Upgrade
Use the following procedure to upgrade the firmware on your FXOS chassis.
Procedure
Step 1
Using a web browser, navigate to http://www.cisco.com/go/firepower9300-software or http://www.cisco.com/ go/firepower4100-software .
36
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Image Management
Firmware Upgrade
The software download page for the FXOS chassis is opened in the browser.
Step 2
Find and then download the appropriate firmware package from Cisco.com to a server that you can access from the FXOS chassis.
Step 3
On the FXOS chassis, enter firmware mode: fxos-chassis #
scope firmware
Step 4
Download the FXOS firmware image to the FXOS chassis: fxos-chassis /firmware #
download image URL
Specify the URL for the file being imported using one of the following syntax:
•
ftp
://
username
@
hostname
/
path
•
scp
://
username
@
hostname
/
path
•
sftp
://
username
@
hostname
/
path
•
tftp
://
hostname
:
port-num
/
path
Step 5
To monitor the download process: fxos-chassis /firmware # show download task image_name detail
Step 6
After the download has completed, you can enter the following command to view the contents of the firmware package: fxos-chassis /firmware # show package image_name expand
Step 7
You can enter the following command to view the version number of the firmware package: fxos-chassis /firmware #
show package
This version number is used in the following step when installing the firmware package.
Step 8
To install the firmware package: a) Enter firmware-install mode: fxos-chassis /firmware #
scope firmware-install
b) Install the firmware package: fxos-chassis /firmware/firmware-install # install firmware pack-version version_number
The system will verify the firmware package and will notify you that the verification process can take several minutes to complete.
c) Enter
yes
to proceed with the verification.
After verifying the firmware package, the system will notify you that the installation process can take several minutes to complete and that the system will reboot during the update process.
d) Enter
yes
to proceed with the installation. Do not power cycle the FXOS chassis during the upgrade process.
Step 9
To monitor the upgrade process: fxos-chassis /firmware/firmware-install #
show detail
Step 10
After the installation has completed, you can enter the following commands to view the current firmware version: fxos-chassis /firmware/firmware-install #
top
fxos-chassis #
scope chassis 1
fxos-chassis /firmware #
show sup version
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
37
Image Management
Firmware Upgrade
The following example upgrades the firmware to version 1.0.10: fxos-chassis#
scope firmware
fxos-chassis /firmware #
download image tftp://10.10.10.1/fxos-k9-fpr9k-firmware.1.0.10.SPA
fxos-chassis /firmware #
show download-task fxos-k9-fpr9k-firmware.1.0.10.SPA detail
Download task:
File Name: fxos-k9-fpr9k-firmware.1.0.10.SPA
Protocol: Tftp
Server: 10.10.10.1
Port: 0
Userid:
Path:
Downloaded Image Size (KB): 2104
Time stamp: 2015-12-04T23:51:57.846
State: Downloading
Transfer Rate (KB/s): 263.000000
Current Task: unpacking image fxos-k9-fpr9k-firmware.1.0.10.SPA on primary(
FSM-STAGE:sam:dme:FirmwareDownloaderDownload:UnpackLocal) fxos-chassis /firmware #
show package fxos-k9-fpr9k-firmware.1.0.10.SPA expand
Package fxos-k9-fpr9k-firmware.1.0.10.SPA:
Images: fxos-k9-fpr9k-fpga.1.0.5.bin
fxos-k9-fpr9k-rommon.1.0.10.bin
fxos-chassis /firmware #
show package
Name Version
--------------------------------------------- ------fxos-k9-fpr9k-firmware.1.0.10.SPA
1.0.10
fxos-chassis /firmware #
scope firmware-install
fxos-chassis /firmware/firmware-install #
install firmware pack-version 1.0.10
Verifying FXOS firmware package 1.0.10. Verification could take several minutes.
Do you want to proceed? (yes/no):yes
FXOS SUP ROMMON: Upgrade from 1.0.10 to 1.0.10
FXOS SUP FPGA : Upgrade from 1.04 to 1.05
This operation upgrades SUP firmware on Security Platform.
Here is the checklist of things that are recommended before starting the install operation
(1) Review current critical/major faults
(2) Initiate a configuration backup
Attention:
The system will be reboot to upgrade the SUP firmware.
The upgrade operation will take several minutes to complete.
PLEASE DO NOT POWER RECYCLE DURING THE UPGRADE.
Do you want to proceed? (yes/no):yes
Upgrading FXOS SUP firmware software package version 1.0.10
command executed
38
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
6
Security Certifications Compliance
•
Security Certifications Compliance, page 39
•
•
Enable Common Criteria Mode, page 40
•
Generate the SSH Host Key, page 40
•
Configure IPSec Secure Channel, page 41
•
Configure Static CRL for a Trustpoint, page 46
•
About the Certificate Revocation List Check, page 47
•
Set the LDAP Key Ring Certificate, page 51
Security Certifications Compliance
United States federal government agencies are sometimes required to use only equipment and software complying with security standards established by the U.S. Department of Defense and global certification organizations. The FXOS chassis supports compliance with several of these security certification standards.
See the following topics for steps to enable features that support compliance with these standards:
•
•
Enable Common Criteria Mode, on page 40
•
Configure IPSec Secure Channel, on page 41
•
Configure Static CRL for a Trustpoint, on page 46
•
About the Certificate Revocation List Check, on page 47
•
Set the LDAP Key Ring Certificate, on page 51
•
Configure Minimum Password Length Check, on page 28
•
Set the Maximum Number of Login Attempts, on page 27
•
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
39
Security Certifications Compliance
Enable FIPS Mode
Note
Note that these topics discuss enabling certifications compliance on the FXOS chassis only. Enabling certification compliance on the FXOS chassis does not automatically propagate compliance to any of its attached logical devices.
Enable FIPS Mode
Perform these steps to enable FIPS mode on your FXOS chassis.
Procedure
What to Do Next
Prior to FXOS release 2.0.1, the existing SSH host key created during first-time setup of a device was hard coded to 1024 bits. To comply with FIPS and Common Criteria certification requirements, you must destroy this old host key and generate a new one using the procedure detailed in
Generate the SSH Host Key, on page
40 . If you do not perform these additional steps, you will not be able to connect to the Supervisor using SSH after the device has rebooted with FIPS mode enabled. If you performed initial setup using FXOS 2.0.1 or later, you do not have to generate a new host key.
Enable Common Criteria Mode
Perform these steps to enable Common Criteria mode on your FXOS chassis.
Procedure
What to Do Next
Prior to FXOS release 2.0.1, the existing SSH host key created during first-time setup of a device was hard coded to 1024 bits. To comply with FIPS and Common Criteria certification requirements, you must destroy this old host key and generate a new one using the procedure detailed in
page 40
. If you do not perform these additional steps, you will not be able to connect to the Supervisor using
SSH after the device has rebooted with Common Criteria mode enabled. If you performed initial setup using
FXOS 2.0.1 or later, you do not have to generate a new host key.
Generate the SSH Host Key
Prior to FXOS release 2.0.1, the existing SSH host key created during initial setup of a device was hard-coded to 1024 bits. To comply with FIPS and Common Criteria certification, you must destroy this old host key and generate a new one. See
or
Enable Common Criteria Mode, on page 40
for more information.
Perform these steps to destroy the old SSH host key and generate a new certifications-compliant one.
40
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Security Certifications Compliance
Configure IPSec Secure Channel
Procedure
Step 1
From the FXOS CLI, enter services mode:
scope system scope services
Step 2
Delete the SSH host key:
delete ssh-server host-key
Step 3
Commit the configuration:
commit-buffer
Step 4
Set the SSH host key size to 2048 bits:
set ssh-server host-key rsa
2048
Step 5
Commit the configuration:
commit-buffer
Step 6
Create a new SSH host key:
create ssh-server host-key commit-buffer
Step 7
Confirm the new host key size:
show ssh-server host-key
Host Key Size: 2048
Configure IPSec Secure Channel
You can configure IPSec on your FXOS chassis to provide end-to-end data encryption and authentication service on data packets going through the public network. This option is one of a number offered for achieving
Common Criteria certification compliance on your system. For more information, see
.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
41
Security Certifications Compliance
Configure IPSec Secure Channel
Note
If you elect to configure enforcement of matching cryptographic key strength between IKE and SA connections (set sa-strength-enforcement to yes in the below procedure):
If SA enforcement is enabled then when IKE negotiated key size is less then ESP negotiated key size, the connection fails.
then when IKE negotiated key size is large or equal than ESP negotiated key size, SA enforcement check passes and the connection is successful.
If SA enforcement is disabled then SA enforcement check passes and the connection is successful.
Perform these steps to configure an IPSec secure channel.
Procedure
Step 1
From the FXOS CLI, enter security mode:
scope system scope security
Step 2
Create the keyring:
enter keyring ssp
! create certreq subject-name subject-name ip ip
Step 3
Enter the associated certificate request information:
enter certreq
Step 4
Set the country:
set country country
Step 5
Set the DNS:
set dns dns
Step 6
Set the email:
set e-mail email
Step 7
Set the IP information:
set fi-a-ip fi-a-ip
set fi-a-ipv6 fi-a-ipv6
set fi-b-ip fi-b-ip
set fi-b-ipv6 fi-b-ipv6
set ipv6 ipv6
Step 8
Set the locality:
set locality locality
42
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Security Certifications Compliance
Configure IPSec Secure Channel
Step 9
Set the organization name:
set org-name org-name
Step 10
Set the organization unit name:
set org-unit-name org-unit-name
Step 11
Set the password:
! set password
Step 12
Set the state:
set state state
Step 13
Set the subject name for the certreq:
set subject-name subject-name
Step 14
Exit:
exit
Step 15
Set the modulus:
set modulus modulus
Step 16
Set the regeneration for the certificate request:
set regenerate { yes | no }
Step 17
Set the trustpoint:
set trustpoint interca
Step 18
Exit:
exit
Step 19
Enter the newly created trustpoint:
enter trustpoint interca
Step 20
Genterate certificate signing request:
set certchain
Example:
-----BEGIN CERTIFICATE-----
MIIF3TCCA8WgAwIBAgIBADANBgkqhkiG9w0BAQsFADBwMQswCQYDVQQGEwJVUzEL
MAkGA1UECAwCQ0ExDDAKBgNVBAcMA1NKQzEOMAwGA1UECgwFQ2lzY28xDTALBgNV
BAsMBFNUQlUxCzAJBgNVBAMMAkNBMRowGAYJKoZIhvcNAQkBFgtzc3BAc3NwLm5l dDAeFw0xNjEyMDgxOTMzNTJaFw0yNjEyMDYxOTMzNTJaMHAxCzAJBgNVBAYTAlVT
MQswCQYDVQQIDAJDQTEMMAoGA1UEBwwDU0pDMQ4wDAYDVQQKDAVDaXNjbzENMAsG
A1UECwwEU1RCVTELMAkGA1UEAwwCQ0ExGjAYBgkqhkiG9w0BCQEWC3NzcEBzc3Au bmV0MIICIjANBgkqhkiG9w0BAQEFAAOCAg8AMIICCgKCAgEA2ukWyMLQuLqTvhq7 zFb3Oz/iyDG/ui6mrLIYn8wE3E39XcXA1/x9IHCmxFKNJdD7EbsggfOuy0Bj+Y4s
+uZ1VapBXV/JrAie7bNn3ZYrI29yuyOrIqoi9k9gL/oRBzH18BwBwGHBOz3hGrSK
Yc2yhsq9y/6yI3nSuLZm6ybmUKjTa+B4YuhDTz4hl/I9x/J5nbGiab3vLDKss1nO xP9+1+Lc690Vl8/mNPWdjCjDI+U/L9keYs/rbZdRSeXy9kMae42+4FlRHDJjPcSN
Yw1g/gcR2F7QUKRygKckJKXDX2QIiGYSctlSHj18O87o5s/pmQAWWRGkKpfDv3oH cMPgI2T9rC0D8NNcgPXj9PFKfexoGNGwNTO85fK3kjgMOdWbdeMG3EihxEEOUPD0
Fdu0HrTM5lvwb+vr5wE9HsAiMJ8UuujmHqH5mlwyy3Me+cEDHo0hLeNs+AFrqEXQ e9S+KZC/dq/9zOLpRsVqSfJsAuVl/QdPDbWShjflE/fP2Wj01PqXywQydzymVvgE wEZaoFg+mlGJm0+q4RDvnpzEviOYNSAGmOkILh5HQ/eYDcxvd0qbORWb31H32ySl
Ila6UTT9+vnND1f838fxvNvr8nyGD2S/LVaxnZlO4jcSIvtdizbbT8u5B4VcLKIC
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
43
Security Certifications Compliance
Configure IPSec Secure Channel
x0vkqjo6RvNZJ52sUaD9C3UodTUCAwEAAaOBgTB/MC8GA1UdHwQoMCYwJKAioCCG
Hmh0dHA6Ly8xOTIuMTY4LjQuMjkvcm9vdGNhLmNybDAdBgNVHQ4EFgQU7Jg01A74 jpx8U0APk76pVfYQQ5AwHwYDVR0jBBgwFoAU7Jg01A74jpx8U0APk76pVfYQQ5Aw
DAYDVR0TBAUwAwEB/zANBgkqhkiG9w0BAQsFAAOCAgEAvI8ky2jiXc4wPiMuxIfY
W7DRmszPUWQ7edor7yxuCqzHLVFFOwYRudsyXbv7INR3rJ/X1cRQj9+KidWWVxpo pFahRhzYxVZ10DHKIzGTQS3jiHgrF3Z8ohWbL15L7PEDlrxMBoJvabPeQRgTmY/n
XZJ7qRYbypO3gUMCaCZ12raJc3/DIpBQ29yweCbUkc9qiHKA0IbnvAxoroHWmBld
94LrJCggfMQTuNJQszJiVVsYJfZ+utlDp2QwfdDv7B0JkwTBjdwRSfotEbc5R18n
BNXYHqxuoNMmqbS3KjCLXcH6xIN8t+UkfP89hvJt/fluJ+s/VJSVZWK4tAWvR7wl
QngCKRJW6FYpzeyNBctiJ07wO+Wt4e3KhIjJDYvA9hFixWcVGDf2r6QW5BYbgGOK
DkHb/gdr/bcdLBKN/PtSJ+prSrpBSaA6rJX8D9UmfhqqN/3f+sS1fM4qWORJc6G2 gAcg7AjEQ/0do512vAI8p8idOg/Wv1O17mavzLpcue05cwMCX9fKxKZZ/+7Pk19Y
ZrXS6uMn/CGnViptn0w+uJ1IRj1oulk+/ZyPtBvFHUkFRnhoWj5SMFyds2IaatyI
47N2ViaZBxhU3GICaH+3O+8rs9Kkz9tBZDSnEJVZA6yxaNCVP1bRUO20G3oRTmSx
8iLBjN+BXggxMmG8ssHisgw=
-----END CERTIFICATE-----
-----BEGIN CERTIFICATE-----
MIIFqDCCA5CgAwIBAgIBBDANBgkqhkiG9w0BAQsFADBwMQswCQYDVQQGEwJVUzEL
MAkGA1UECAwCQ0ExDDAKBgNVBAcMA1NKQzEOMAwGA1UECgwFQ2lzY28xDTALBgNV
BAsMBFNUQlUxCzAJBgNVBAMMAkNBMRowGAYJKoZIhvcNAQkBFgtzc3BAc3NwLm5l dDAeFw0xNjEyMTUyMTM0NTRaFw0yNjEyMTMyMTM0NTRaMHwxCzAJBgNVBAYTAlVT
MQswCQYDVQQIDAJDQTEPMA0GA1UECgwGbmV3c3RnMRAwDgYDVQQLDAduZXdzdGJ1
MRMwEQYDVQQDDAppbnRlcm0xLWNhMSgwJgYJKoZIhvcNAQkBFhlpbnRlcm0xLWNh
QGludGVybTEtY2EubmV0MIICIjANBgkqhkiG9w0BAQEFAAOCAg8AMIICCgKCAgEA wLpNnyEx5I4P8uDoWKWF3IZsegjhLANsodxuAUmhmwKekd0OpZZxHMw1wSO4IBX5
4itJS0xyXFzPmeptG3OXvNqCcsT+4BXl3DoGgPMULccc4NesHeg2z8+q3SPA6uZh iseWNvKfnUjixbQEBtcrWBiSKnZuOz1cpuBn34gtgeFFoCEXN+EZVpPESiancDVh
8pCPlipc/08ZJ3o9GW2j0eHJN84sguIEDL812ROejQvpmfqGUq11stkIIuh+wB+V
VRhUBVG7pV57I6DHeeRp6cDMLXaM3iMTelhdShyo5YUaRJMak/t8kCqhtGXfuLlI
E2AkxKXeeveR9n6cpQd5JiNzCT/t9IQL/T/CCqMICRXLFpLCS9o5S5O2B6QFgcTZ yKR6hsmwe22wpK8QI7/5oWNXlolb96hHJ7RPbG7RXYqmcLiXY/d2j9/RuNoPJawI hLkfhoIdPA28xlnfIB1azCmMmdPcBO6cbUQfCj5hSmk3StVQKgJCjaujz55TGGd1
GjnxDMX9twwz7Ee51895Xmtr24qqaCXJoW/dPhcIIXRdJPMsTJ4yPG0BieuRwd0p i8w/rFwbHzv4C9Fthw1JrRxH1yeHJHrLlZgJ5txSaVUIgrgVCJaf6/jrRRWoRJwt
AzvnzYql2dZPCcEAYgP7JcaQpvdpuDgq++NgBtygiqECAwEAAaNBMD8wDAYDVR0T
BAUwAwEB/zAvBgNVHR8EKDAmMCSgIqAghh5odHRwOi8vMTkyLjE2OC40LjI5L2lu dGVybS5jcmwwDQYJKoZIhvcNAQELBQADggIBAG/XujJh5G5UWo+cwTSitAezWbJA h1dAiXZ/OYWZSxkFRliErKdupLqL0ThjnX/wRFfEXbrBQwm5kWAUUDr97D1Uz+2A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-----END CERTIFICATE-----
ENDOFBUF
Step 21
Show the certificate signing request:
show certreq
Example:
44
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Security Certifications Compliance
Configure IPSec Secure Channel
Firepower-chassis# /security/keyring # show certreq
Certificate request subject name: SSP
Certificate request ip address: 192.168.0.111
Certificate request FI A ip address: 0.0.0.0
Certificate request FI B ip address: 0.0.0.0
Certificate request e-mail name:
Certificate request ipv6 address: ::
Certificate request FI A ipv6 address: ::
Certificate request FI B ipv6 address: ::
Certificate request country name: US
State, province or county (full name): CA
Locality name (eg, city): SJC
Organisation name (eg, company): Cisco
Organisational Unit Name (eg, section): Sec
DNS name (subject alternative name):
Request:
-----BEGIN CERTIFICATE REQUEST-----
MIICwTCCAakCAQAwVTELMAkGA1UEBhMCVVMxCzAJBgNVBAgMAkNBMQwwCgYDVQQH
DANTSkMxDjAMBgNVBAoMBUNpc2NvMQ0wCwYDVQQLDARTVEJVMQwwCgYDVQQDDANT
U1AwggEiMA0GCSqGSIb3DQEBAQUAA4IBDwAwggEKAoIBAQDq292Rq3t0laoxPbfE p/lTKr6rxFhPqSSbtm6sXer//VZFiDTWODockDItuf4Kja215mIS0RyvEYVeRgAs wbN459wm0BASd8xCjIhsuHDV7yHu539BnvRW6Q2o+gHeSRwckqjClK/tsIxsPkV0
6OduZYXk2bnsLWs6tNk3uzOIT2Q0FcZ1ET66C8fyyKWTrmvcZjDjkMm2nDFsPlX9
39TYPItDkJE3PocqyaCqmT4uobOuvQeLJh/efkBvwhb4BF8vwzRpHWTdjjU5YnR1 qiR4q7j1RmzVFxCDY3IVP/KDBoa5NyCLEUZECP5QCQFDzIRETZwVOKtxUVG0Nljd
K5TxAgMBAAGgJzAlBgkqhkiG9w0BCQ4xGDAWMBQGA1UdEQQNMAuCA1NTUIcEwKgA rjANBgkqhkiG9w0BAQsFAAOCAQEARtRBoInxXkBYNlVeEoFCqKttu3+Hc7UdyoRM
2L2pjx5OHbQICC+8NRVRMYujTnp67BWuUZZl03dGP4/lbN6bC9P3CvkZdKUsJkN0 m1Ye9dgz7MO/KEcosarmoMl9WB8LlweVdt6ycSdJzs9shOxwT6TAZPwL7gq/1ShF
RJh6sq5W9p6E0SjYefK62E7MatRjDjS8DXoxj6gfn9DqK15iVpkK2QqT5rneSGj+
R+20TcUnT0h/S5K/bySEM/3U1gFxQCOzbzPuHkj28kXAVczmTxXEkJBFLVduWNo6
DT3u0xImiPR1sqW1jpMwbhC+ZGDtvgKjKHToagup9+8R9IMcBQ==
-----END CERTIFICATE REQUEST-----
Step 22
Enter IPSec mode:
scope ipsec
Step 23
Set the log verbose level:
set log-level log_level
Step 24
Create and enter an IPSec connection:
enter connection connection_name
Step 25
Set IPSec mode to tunnel or transport:
set mode tunnel_or_transport
Step 26
Set the local IP address:
set local-addr ip_address
Step 27
Set the remote IP address:
set remote-addr ip_address
Step 28
If using tunnel mode, set the remote subnet:
set remote-subnet ip/mask
Step 29
(Optional) Set the remote identity:
set remote-ike-ident remote_identity_name
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
45
Security Certifications Compliance
Configure Static CRL for a Trustpoint
Step 30
Set the keyring name:
set keyring-name name
Step 31
(Optional) Set the keyring password:
set keyring-passwd passphrase
Step 32
(Optional) Set the IKE-SA lifetime in minutes:
set ike-rekey-time minutes
The
minutes
value can be any integer between 60-1440, inclusive.
Step 33
(Optional) Set the Child SA lifetime in minutes (30-480):
set esp-rekey-time minutes
The
minutes
value can be any integer between 30-480, inclusive.
Step 34
(Optional) Set the number of retransmission sequences to perform during initial connect:
set keyringtries retry_number
The
retry_number
value can be any integer between 1-5, inclusive.
Step 35
(Optional) Enable or disable the certificate revocation list check:
set revoke-policy { relaxed | strict }
Step 36
Enable the connection:
set admin-state enable
Step 37
Reload all connections:
reload-conns
Step 38
(Optional) Add the existing trustpoint name to IPsec:
create authority trustpoint_name
Step 39
Configure the enforcement of matching cryptographic key strength between IKE and SA connections:
set sa-strength-enforcement yes_or_no
Configure Static CRL for a Trustpoint
Revoked certifications are kept in the Certification Revocation List (CRL). Client applications use the CRL to check the authentication of a server. Server applications utilize the CRL to grant or deny access requests from client applications which are no longer trusted.
You can configure your FXOS chassis to validate peer certificates using Certification Revocation List (CRL) information. This option is one of a number offered for achieving Common Criteria certification compliance on your system. For more information, see
Security Certifications Compliance, on page 39
.
Perform these steps to validate peer certificates using CRL information.
Procedure
Step 1
From the FXOS CLI, enter security mode:
scope security
46
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Security Certifications Compliance
About the Certificate Revocation List Check
Step 2
Enter trustpoint mode:
scope trustpoint trustname
Step 3
Enter revoke mode:
scope revoke
Step 4
Download the CRL file(s):
import crl protocol ://
user_id
@
CA_or_CRL_issuer_IP
/tmp/
DoDCA1CRL1.crl
Step 5
(Optional) Show the status of the import process of CRL information:
show import-task detail
Step 6
Set the certificate revocation method to CRL-only:
set certrevokemethod {crl}
About the Certificate Revocation List Check
You can configure your Certificate Revocation List (CRL) check mode to be either strict or relaxed in IPSec and secure LDAP connections.
Dynamic (non-static) CRL information is harvested from the CDP information of an X.509 certificate, and indicates dynamic CRL information. Static CRL information is downloaded by system administration manually, and indicates local CRL information in the FXOS system. The dynamic CRL information is only processed against the current processing certificate in the certificate chain. The static CRL is applied to the whole peer certificate chain.
For steps to enable or disable certificate revocation checks for your secure LDAP and IPSec connections, see
Configure IPSec Secure Channel, on page 41
and
Creating an LDAP Provider, on page 102
.
Note
• If the Certificate Revocation Check Mode is set to Strict, static CRL is only applicable when the peer certificate chain has a level of 1 or higher. (For example, when the peer certificate chain only contains the root CA certificate and the peer certificate signed by the root CA.)
• When configuring static CRL for IPSec, the Authority Key Identifier (authkey) field must be present in the imported CRL file. Otherwise, IPSec considers it invalid.
• Static CRL takes precedence over Dynamic CRL from the same issuer. When validating the peer certificate, if a valid (determined) static CRL of the same issuer exists, the CDP in the peer certificate is ignored.
The following tables describe the connection results, depending on your certificate revocation list check setting and certificate validation.
Table 1: Certificate Revocation Check Mode set to Strict without a local static CRL
Without local static CRL
Checking peer certificate chain
LDAP Connection
Full certificate chain is required
IPSec Connection
Full certificate chain is required
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
47
Security Certifications Compliance
About the Certificate Revocation List Check
Without local static CRL
Checking CDP in peer certificate chain
LDAP Connection
Full certificate chain is required
CDP checking for Root CA certificate of the peer certificate chain
Yes
Any certificate validation failure in the peer certificate chain
Connection fails with syslog message
Any certificate revoked in the peer certificate chain
Connection fails with syslog message
One CDP is missing the peer certificate chain
Connection fails with syslog message
IPSec Connection
Full certificate chain is required
Not applicable
Connection fails with syslog message
Connection fails with syslog message
Peer certificate: connection fails with syslog message
Intermediate CAs: connection succeeds
Connection succeeds One CDP CRL is empty in the peer certificate chain with valid signature
Connection fails with syslog message
Any CDP in the peer certificate chain cannot be downloaded
Connection fails with syslog message
Certificate has CDP, but the CDP server is down
Certificate has CDP, server is up, and CRL is on CDP, but the CRL has an invalid signature
Connection fails with syslog message
Connection fails with syslog message
Peer certificate: Connection fails with syslog message
Intermediate CA: connection succeeds
Peer certificate: Connection fails with syslog message
Intermediate CA: connection succeeds
Peer certificate: Connection fails with syslog message
Intermediate CA: connection succeeds
Table 2: Certificate Revocation Check Mode set to Strict with a local static CRL
With local static CRL
Checking peer certificate chain
LDAP Connection
Full certificate chain is required
Checking CDP in peer certificate chain
Full certificate chain is required
IPSec Connection
Full certificate chain is required
Full certificate chain is required
48
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Security Certifications Compliance
About the Certificate Revocation List Check
With local static CRL
CDP checking for Root CA certificate of the peer certificate chain
LDAP Connection
Yes
Any certificate validation failure in the peer certificate chain
Connection fails with syslog message
Any certificate revoked in the peer certificate chain
Connection fails with syslog message
One CDP is missing the peer certificate chain (Certificate Chain level is 1)
Connection succeeds
One CDP CRL is empty in the peer certificate chain (Certificate Chain level is 1)
Connection succeeds
Any CDP in the peer certificate chain cannot be downloaded
(Certificate Chain level is 1)
Connection succeeds
Certificate has CDP, but the CDP server is down (Certificate Chain level is 1)
Connection succeeds
Certificate has CDP, server is up, and CRL is on CDP, but the CRL has an invalid signature (Certificate
Chain level is 1)
Connection succeeds
Peer Certificate Chain level is higher than 1
Connection fails with syslog message
IPSec Connection
Not applicable
Connection fails with syslog message
Connection fails with syslog message
Connection succeeds
Connection succeeds
Connection succeeds
Connection succeeds
Connection succeeds
If combined with CDP, connection succeeds
If there is no CDP, connection fails with syslog message
Table 3: Certificate Revocation Check Mode set to Relaxed without a local static CRL
Without local static CRL
Checking peer certificate chain
Checking CDP in peer certificate chain
LDAP Connection
Full certificate chain
Full certificate chain
IPSec Connection
Full certificate chain
Full certificate chain
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
49
Security Certifications Compliance
About the Certificate Revocation List Check
Without local static CRL
CDP checking for Root CA certificate of the peer certificate chain
LDAP Connection
Yes
Any certificate validation failure in the peer certificate chain
Connection fails with syslog message
Any certificate revoked in the peer certificate chain
Connection fails with syslog message
One CDP is missing the peer certificate chain
Connection succeeds
One CDP CRL is empty in the peer certificate chain
Connection succeeds
Any CDP in the peer certificate chain cannot be downloaded
Connection succeeds
Certificate has CDP, but the CDP server is down
Connection succeeds
Certificate has CDP, server is up, and CRL is on CDP, but the CRL has an invalid signature
Connection succeeds
IPSec Connection
Not applicable
Connection fails with syslog message
Connection fails with syslog message
Connection succeeds
Connection succeeds
Connection succeeds
Connection succeeds
Connection succeeds
Table 4: Certificate Revocation Check Mode set to Relaxed with a local static CRL
With local static CRL
Checking peer certificate chain
Checking CDP in peer certificate chain
CDP checking for Root CA certificate of the peer certificate chain
LDAP Connection
Full certificate chain
Full certificate chain
Yes
Any certificate validation failure in the peer certificate chain
Connection fails with syslog message
Any certificate revoked in the peer certificate chain
Connection fails with syslog message
IPSec Connection
Full certificate chain
Full certificate chain
Not applicable
Connection fails with syslog message
Connection fails with syslog message
50
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Security Certifications Compliance
Set the LDAP Key Ring Certificate
With local static CRL LDAP Connection
One CDP is missing the peer certificate chain (Certificate Chain level is 1)
Connection succeeds
One CDP CRL is empty in the peer certificate chain (Certificate Chain level is 1)
Connection succeeds
Any CDP in the peer certificate chain cannot be downloaded
(Certificate Chain level is 1)
Connection succeeds
Certificate has CDP, but the CDP server is down (Certificate Chain level is 1)
Connection succeeds
Certificate has CDP, server is up, and CRL is on CDP, but the CRL has an invalid signature (Certificate
Chain level is 1)
Connection succeeds
Peer Certificate Chain level is higher than 1
Connection fails with syslog message
IPSec Connection
Connection succeeds
Connection succeeds
Connection succeeds
Connection succeeds
Connection succeeds
If combined with CDP, connection succeeds
If there is no CDP, connection fails with syslog message
Set the LDAP Key Ring Certificate
You can configure a secure LDAP client key ring certificate to support a TLS connection on your FXOS chassis. This option is one of a number offered for achieving Common Criteria certification compliance on your system. For more information, see
Security Certifications Compliance, on page 39
.
Note
If Common Criteria mode is enabled, you must have SSL enabled, and you must use the server DNS information to create the key ring certificate.
If SSL is enabled for the LDAP server entry, key ring information is referenced and checked when forming a connection.
LDAP server information has to be DNS information in the CC mode for the secure LDAP connection (with
SSL enabled).
Perform these steps to configure a secure LDAP client key ring certificate:.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
51
Set the LDAP Key Ring Certificate
Procedure
Step 1
From the FXOS CLI, enter security mode:
scope security
Step 2
Enter LDAP mode:
scope ldap
Step 3
Enter LDAP server mode:
enter server {server_ip|server_dns}
Step 4
Set the LDAP key ring:
set keyring keyring_name
Step 5
Commit the configuration:
commit-buffer
Security Certifications Compliance
52
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
7
System Administration
•
Changing the Management IP Address, page 53
•
Changing the Application Management IP, page 55
•
•
Rebooting the FXOS Chassis, page 59
•
Powering Off the FXOS Chassis, page 60
•
Install a Trusted Identity Certificate, page 60
•
Recovering from a Software Failure, page 65
•
Recovering from a Corrupted File System, page 69
Changing the Management IP Address
Before You Begin
You can change the management IP address on the FXOS chassis from the FXOS CLI.
Note
After changing the management IP address, you will need to reestablish any connections to Firepower
Chassis Manager or the FXOS CLI using the new address.
Procedure
Step 1
Connect to the FXOS CLI (see
Accessing the FXOS CLI, on page 8
).
Step 2
To configure an IPv4 management IP address: a) Set the scope for fabric-interconnect a:
Firepower-chassis#
scope fabric-interconnect a
b) To view the current management IP address, enter the following command:
Firepower-chassis /fabric-interconnect #
show
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
53
System Administration
Changing the Management IP Address
c) Enter the following command to configure a new management IP address and gateway:
Firepower-chassis /fabric-interconnect # set out-of-band ip ip_address netmask network_mask gw
gateway_ip_address
d) Commit the transaction to the system configuration:
Firepower-chassis /fabric-interconnect* #
commit-buffer
Step 3
To configure an IPv6 management IP address: a) Set the scope for fabric-interconnect a:
Firepower-chassis#
scope fabric-interconnect a
b) Set the scope for management IPv6 configuration:
Firepower-chassis /fabric-interconnect #
scope ipv6-config
c) To view the current management IPv6 address, enter the following command:
Firepower-chassis /fabric-interconnect/ipv6-config #
show ipv6-if
d) Enter the following command to configure a new management IP address and gateway:
Firepower-chassis /fabric-interconnect/ipv6-config # set out-of-band ipv6 ipv6_address ipv6-prefix
prefix_length ipv6-gw gateway_address e) Commit the transaction to the system configuration:
Firepower-chassis /fabric-interconnect/ipv6-config* #
commit-buffer
The following example configures an IPv4 management interface and gateway:
Firepower-chassis#
scope fabric-interconnect a
Firepower-chassis /fabric-interconnect #
show
Fabric Interconnect:
ID OOB IP Addr
Prefix Operability
OOB Gateway OOB Netmask OOB IPv6 Address OOB IPv6 Gateway
---- --------------- --------------- --------------- ---------------- ----------------
------ -----------
64
A 192.0.2.112
Operable
192.0.2.1
255.255.255.0
:: ::
Firepower-chassis /fabric-interconnect # set out-of-band ip 192.0.2.111 netmask 255.255.255.0
gw 192.0.2.1
Warning: When committed, this change may disconnect the current CLI session
Firepower-chassis /fabric-interconnect* #
commit-buffer
Firepower-chassis /fabric-interconnect #
The following example configures an IPv6 management interface and gateway:
Firepower-chassis#
scope fabric-interconnect a
Firepower-chassis /fabric-interconnect #
scope ipv6-config
Firepower-chassis /fabric-interconnect/ipv6-config #
show ipv6-if
Management IPv6 Interface:
IPv6 Address Prefix IPv6 Gateway
----------------------------------- ---------- ------------
2001::8998 64 2001::1
Firepower-chassis /fabric-interconnect/ipv6-config # set out-of-band ipv6 2001::8999 ipv6-prefix 64 ipv6-gw 2001::1
Firepower-chassis /fabric-interconnect/ipv6-config* #
commit-buffer
Firepower-chassis /fabric-interconnect/ipv6-config #
54
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Changing the Application Management IP
Changing the Application Management IP
You can change the management IP address on the application(s) attached to your FXOS chassis from the
FXOS CLI. To do so, you must first change the IP information at the FXOS platform level, then change the
IP information at the application level.
Note
Attempts to make these changes using the FXOS Chassis Manager may result in a service interruption.
To avoid any potential service interruptions, you must perform these changes using the FXOS CLI.
Procedure
Step 1
Connect to the FXOS CLI. (See
Accessing the FXOS CLI, on page 8
).
Step 2
Scope to the logical device:
scope ssa
scope logical-device logical_device_name
Step 3
Scope to the management bootstrap and configure the new management bootstrap parameters. Note that there are differences between deployments:
For standalone configuration of an ASA logical device: a)
scope mgmt-bootstrap asa
b)
scope ipv4_or_6 slot_number default c) IPv4 only:
set ip ipv4_address mask network_mask d) IPv6 only:
set ip ipv6_address prefix-length prefix_length_number e) set gateway gateway_ip_address f) Commit the configuration:
commit-buffer
For clustered configuration of ASA logical devices: a)
scope cluster-bootstrap
b) For IPv4 only:
set virtual ipv4 ipv_address masknetwork_mask c) For IPv6 only:
set virtual ipv6 ipv6_address prefix_lengthprefix_length_number d)
set ipv{4|6} pool start_ip end_ip e) set ipv{4|6} gateway gateway_ip_address f) Commit the configuration:
commit-buffer
For standalone and clustered configurations of FTD logical devices:
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
55
System Administration
Changing the Application Management IP
a)
scope mgmt-bootstrap ftd
b) scope ipv4_or_6 slot_number firepower c) IPv4 only:
set ip ip_address masknetwork_mask d) IPv6 only:
set ip ipv6_address prefix-lengthprefix_length_number e) set gateway gateway_ip_address f) Commit the configuration:
commit-buffer
Note
For a clustered configuration, you must repeat these steps for each application attached to the FXOS
Chassis. In the case of an inter-chassis cluster or HA configuration, you must repeat these steps for each application on both chassis.
Step 4
Scope back to ssa mode:
scope ssa
Step 5
Scope to the slot:
scope slot slot_number
Step 6
Scope to the application.
scope app-instance asa_or_ftd
Step 7
Clear the management bootstrap information.
clear mgmt-bootstrap commit-buffer
Note
For a clustered configuration, you must clear the management bootstrap information for each application attached to the FXOS Chassis. In the case of an inter-chassis cluster or HA configuration, you must repeat these steps for each application on both chassis.
Step 8
Disable the application: a) Scope back to ssa mode:
scope ssa
b) Scope to the slot:
scope slot slot_number c) Scope to the application:
scope app-instance asa_or_ftd d) Disable the application:
disable
e) Commit the configuration:
commit-buffer
Note
For a clustered configuration, you must disable each application attached to the FXOS Chassis. In the case of an inter-chassis cluster or HA configuration, you must repeat these steps for each application on both chassis.
Step 9
When the application is offline, and the slot comes back online, re-enable the application: a) Scope back to ssa mode:
scope ssa
56
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Pre-Login Banner
b) Scope to the slot:
scope slot slot_number c) Scope to the application:
scope app-instance asa_or_ftd d) Enable the application:
enable
e) Commit the configuration:
commit-buffer
Note
For a clustered configuration, you must repeat this step for each application attached to the FXOS
Chassis. In the case of an inter-chassis cluster or HA configuration, you must repeat these steps for each application on both chassis.
Pre-Login Banner
With a pre-login banner, when a user logs into Firepower Chassis Manager, the system displays the banner text and the user must click
OK
on the message screen before the system prompts for the username and password. If a pre-login banner is not configured, the system goes directly to the username and password prompt.
When a user logs into the FXOS CLI, the system displays the banner text, if configured, before it prompts for the password.
Creating the Pre-Login Banner
Procedure
Step 1
Connect to the FXOS CLI (see
Accessing the FXOS CLI, on page 8
).
Step 2
Enter security mode:
Firepower-chassis#
scope security
Step 3
Enter banner security mode:
Firepower-chassis /security #
scope banner
Step 4
Enter the following command to create a pre-login banner:
Firepower-chassis /security/banner #
create pre-login-banner
Step 5
Specify the message that FXOS should display to the user before they log into Firepower Chassis Manager or the FXOS CLI:
Firepower-chassis /security/banner/pre-login-banner* #
set message
Launches a dialog for entering the pre-login banner message text.
Step 6
At the prompt, type a pre-login banner message. You can enter any standard ASCII character in this field.
You can enter multiple lines of text with each line having up to 192 characters. Press
Enter
between lines.
On the line following your input, type ENDOFBUF and press
Enter
to finish.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
57
System Administration
Modifying the Pre-Login Banner
Press Ctrl and C to cancel out of the set message dialog.
Step 7
Commit the transaction to the system configuration:
Firepower-chassis /security/banner/pre-login-banner* #
commit-buffer
The following example creates the pre-login banner:
Firepower-chassis#
scope security
Firepower-chassis /security #
scope banner
Firepower-chassis /security/banner #
create pre-login-banner
Firepower-chassis /security/banner/pre-login-banner* #
set message
Enter lines one at a time. Enter ENDOFBUF to finish. Press ^C to abort.
Enter prelogin banner:
>Welcome to the Firepower Security Appliance
>**Unauthorized use is prohibited**
>ENDOFBUF
Firepower-chassis /security/banner/pre-login-banner* #
commit-buffer
Firepower-chassis /security/banner/pre-login-banner #
Modifying the Pre-Login Banner
Procedure
Step 1
Connect to the FXOS CLI (see
Accessing the FXOS CLI, on page 8
).
Step 2
Enter security mode:
Firepower-chassis#
scope security
Step 3
Enter banner security mode:
Firepower-chassis /security #
scope banner
Step 4
Enter pre-login-banner banner security mode:
Firepower-chassis /security/banner #
scope pre-login-banner
Step 5
Specify the message that FXOS should display to the user before they log into Firepower Chassis Manager or the FXOS CLI:
Firepower-chassis /security/banner/pre-login-banner #
set message
Launches a dialog for entering the pre-login banner message text.
Step 6
At the prompt, type a pre-login banner message. You can enter any standard ASCII character in this field.
You can enter multiple lines of text with each line having up to 192 characters. Press
Enter
between lines.
On the line following your input, type ENDOFBUF and press
Enter
to finish.
Press Ctrl and C to cancel out of the set message dialog.
Step 7
Commit the transaction to the system configuration:
Firepower-chassis /security/banner/pre-login-banner* #
commit-buffer
The following example modifies the pre-login banner:
Firepower-chassis#
scope security
Firepower-chassis /security #
scope banner
Firepower-chassis /security/banner #
scope pre-login-banner
Firepower-chassis /security/banner/pre-login-banner #
set message
58
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Deleting the Pre-Login Banner
Enter lines one at a time. Enter ENDOFBUF to finish. Press ^C to abort.
Enter prelogin banner:
>Welcome to the Firepower Security Appliance
>**Unauthorized use is prohibited**
>ENDOFBUF
Firepower-chassis /security/banner/pre-login-banner* #
commit-buffer
Firepower-chassis /security/banner/pre-login-banner #
Deleting the Pre-Login Banner
Procedure
Step 1
Connect to the FXOS CLI (see
Accessing the FXOS CLI, on page 8
).
Step 2
Enter security mode:
Firepower-chassis#
scope security
Step 3
Enter banner security mode:
Firepower-chassis /security #
scope banner
Step 4
Delete the pre-login banner from the system:
Firepower-chassis /security/banner #
delete pre-login-banner
Step 5
Commit the transaction to the system configuration:
Firepower-chassis /security/banner* #
commit-buffer
The following example deletes the pre-login banner:
Firepower-chassis#
scope security
Firepower-chassis /security #
scope banner
Firepower-chassis /security/banner #
delete pre-login-banner
Firepower-chassis /security/banner* #
commit-buffer
Firepower-chassis /security/banner #
Rebooting the FXOS Chassis
Procedure
Step 1
Choose
Overview
to open the Overview page.
Step 2
Click
Reboot
next to the Chassis Uptime in the upper-right corner of the Overview page.
Step 3
Click
Yes
to verify that you want to power off the FXOS chassis.
The system will gracefully shut down any logical devices configured on the system and then power down each security module/engine before finally powering down and then restarting the FXOS chassis. This process takes approximately 15-20 minutes.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
59
System Administration
Powering Off the FXOS Chassis
Powering Off the FXOS Chassis
Procedure
Step 1
Choose
Overview
to open the Overview page.
Step 2
Click
Shutdown
next to the Chassis Uptime in the upper-right corner of the Overview page.
Step 3
Click
Yes
to verify that you want to power off the FXOS chassis.
The system will gracefully shut down any logical devices configured on the system and then power down each security module/engine before finally powering down the FXOS chassis.
Install a Trusted Identity Certificate
After initial configuration, a self-signed SSL certificate is generated for use with the FXOS chassis web application. Because that certificate is self-signed, client browsers do not automatically trust it. The first time a new client browser accesses the FXOS chassis web interface, the browser will throw an SSL warning, requiring the user to accept the certificate before accessing the FXOS chassis. You can use the following procedure to generate a Certificate Signing Request (CSR) using the FXOS CLI and install the resulting identity certificate for use with the FXOS chassis. This identity certificate allows a client browser to trust the connection, and bring up the web interface with no warnings.
Procedure
Step 1
Connect to the FXOS CLI. (See
Accessing the FXOS CLI, on page 8
).
Step 2
Enter the security module:
scope security
Step 3
Create a keyring:
create keyring keyring_name
Step 4
Set a modulus size for the private key:
set modulus size
Step 5
Commit the configuration:
commit-buffer
Step 6
Configure the CSR fields. The certificate can be generated with basic options (for example, a subject-name), and optionally more advanced options that allow information like locale and organization to be embedded in the certificate. Note that when you configure the CSR fields, the system prompts for a certificate password.
create certreq certreq subject_name
password
set country country
set state state
set locality locality
60
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Install a Trusted Identity Certificate
set org-name organization_name
set org-unit-name organization_unit_name
set subject-name subject_name
Step 7
Commit the configuration:
commit-buffer
Step 8
Export the CSR to provide to your certificate authority.
a) Show the full CSR:
show certreq
b) Copy the output starting with (and including) "-----BEGIN CERTIFICATE REQUEST-----", ending with
(and including) "-----END CERTIFICATE REQUEST-----":
Example:
-----BEGIN CERTIFICATE REQUEST-----
MIIC6zCCAdMCAQAwdzELMAkGA1UEBhMCVVMxEzARBgNVBAgMCkNhbGlmb3JuaWEx
ETAPBgNVBAcMCFNhbiBKb3NlMRYwFAYDVQQKDA1DaXNjbyBTeXN0ZW1zMQwwCgYD
VQQLDANUQUMxGjAYBgNVBAMMEWZwNDEyMC50ZXN0LmxvY2FsMIIBIjANBgkqhkiG
9w0BAQEFAAOCAQ8AMIIBCgKCAQEAs0ON5gagkfZ2fi4JVEANG+7YGgcHbnUt7LpV yMChnKOPJjBwkUMNQA1mQsRQDcbJ232/sK0fMSnyqOL8JzC7itxeVEZRyz7/ax7W
GNveg/XP+zd03nt4GXM63FsrPcPmA7EwgqDSLoShtBEV10hhf4+Nw4pKCZ+eSSkS
JkTB1ZHaKV9bttYg3kf/UEUUgk/EyrVq3B+u2DsooPVq76mTm8BwYMqHbJEv4Pmu
RjWE88yEvVwH7JTEij9OvxbatjDjVSJHZBURtCanvyBvGuLP/Q/Nmv3Lo3G9ITbL
L5gIYZVatTxp6HTUezH2MIIzOavU6d1tB9rnyxgGth5dPV0dhQIDAQABoC8wLQYJ
KoZIhvcNAQkOMSAwHjAcBgNVHREEFTATghFmcDQxMjAudGVzdC5sb2NhbDANBgkq hkiG9w0BAQsFAAOCAQEAZUfCbwx9vt5aVDcL+tATu5xFE3LA310ck6GjlNv6W/6r jBNLxusYi1rZZcW+CgnvNs4ArqYGyNVBySOavJO/VvQ1KfyxxJ1OIkyx3RzEjgK0 zzyoyrG+EZXC5ShiraS8HuWvE2wFM2wwWNtHWtvcQy55+/hDPD2Bv8pQOC2Zng3I kLfG1dxWf1xAxLzf5J+AuIQ0CM5HzM9Zm8zREoWT+xHtLSqAqg/aCuomN9/vEwyU
OYfoJMvAqC6AZyUnMfUfCoyuLpLwgkxB0gyaRdnea5RhiGjYQ2lDXYDjEXp7rCx9
+6bvDl1n70JCegHdCWtP75SaNyaBEPkO0365rTckbw==
-----END CERTIFICATE REQUEST-----
Step 9
Exit the certreq mode:
exit
Step 10
Exit the keyring mode:
exit
Step 11
Note
All certificates must be in Base64 format to be imported into FXOS. If the certificate or chain received from the Certificate Authority is in a different format, you must first convert it with an SSL tool such as OpenSSL.
Create a new trustpoint to hold the certificate chain.
create trustpoint trustpoint_name
Step 12
Set the generated CSR in the trustpoint:
set certchain
Step 13
Note
For a Certificate Authority that uses intermediate certificates, the root and intermediate certificates must be combined. In a text file, paste the root certificate at the top, followed by each intermediate certificate in the chain, including all BEGIN CERTIFICATE and END CERTIFICATE flags. Copy and paste that entire text block into the trustpoint.
Enter the CSR output you copied in step 8, following the instructions on screen.
Example:
Enter lines one at a time. Enter ENDOFBUF to finish. Press ^C to abort.
Trustpoint Certificate Chain:
>
-----BEGIN CERTIFICATE-----
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
61
System Administration
Install a Trusted Identity Certificate
>
MIICDTCCAbOgAwIBAgIQYIutxPDPw6BOp3uKNgJHZDAKBggqhkjOPQQDAjBTMRUw
>
EwYKCZImiZPyLGQBGRYFbG9jYWwxGDAWBgoJkiaJk/IsZAEZFghuYWF1c3RpbjEg
>
MB4GA1UEAxMXbmFhdXN0aW4tTkFBVVNUSU4tUEMtQ0EwHhcNMTUwNzI4MTc1NjU2
>
WhcNMjAwNzI4MTgwNjU2WjBTMRUwEwYKCZImiZPyLGQBGRYFbG9jYWwxGDAWBgoJ
>
kiaJk/IsZAEZFghuYWF1c3RpbjEgMB4GA1UEAxMXbmFhdXN0aW4tTkFBVVNUSU4t
>
UEMtQ0EwWTATBgcqhkjOPQIBBggqhkjOPQMBBwNCAASvEA27V1Enq1gMtLkvJ6rx
>
GXRpXWIEyuiBM4eQRoqZKnkeJUkm1xmqlubaDHPJ5TMGfJQYszLBRJPq+mdrKcDl
>
o2kwZzATBgkrBgEEAYI3FAIEBh4EAEMAQTAOBgNVHQ8BAf8EBAMCAYYwDwYDVR0T
>
AQH/BAUwAwEB/zAdBgNVHQ4EFgQUyInbDHPrFwEEBcbxGSgQW7pOVIkwEAYJKwYB
>
BAGCNxUBBAMCAQAwCgYIKoZIzj0EAwIDSAAwRQIhAP++QJTUmniB/AxPDDN63Lqy
>
18odMDoFTkG4p3Tb/2yMAiAtMYhlsv1gCxsQVOw0xZVRugSdoOak6n7wCjTFX9jr
>
RA==
>
-----END CERTIFICATE-----
>
ENDOFBUF
Step 14
Commit the configuration:
commit-buffer
Step 15
Exit the trustpoint mode:
exit
Step 16
Enter the keyring mode:
scope keyring keyring_name
Step 17
Associate the trustpoint created in step 13 with the keyring that was created for the CSR:
set trustpoint trustpoint_name
Step 18
Import the signed identity certificate for the server.
set cert
Step 19
Paste the contents of the identity certificate provided by the Certificate authority:
Example:
Enter lines one at a time. Enter ENDOFBUF to finish. Press ^C to abort.
Keyring certificate:
>
-----BEGIN CERTIFICATE-----
>
MIIE8DCCBJagAwIBAgITRQAAAArehlUWgiTzvgAAAAAACjAKBggqhkjOPQQDAjBT
>
MRUwEwYKCZImiZPyLGQBGRYFbG9jYWwxGDAWBgoJkiaJk/IsZAEZFghuYWF1c3Rp
>
bjEgMB4GA1UEAxMXbmFhdXN0aW4tTkFBVVNUSU4tUEMtQ0EwHhcNMTYwNDI4MTMw
>
OTU0WhcNMTgwNDI4MTMwOTU0WjB3MQswCQYDVQQGEwJVUzETMBEGA1UECBMKQ2Fs
>
aWZvcm5pYTERMA8GA1UEBxMIU2FuIEpvc2UxFjAUBgNVBAoTDUNpc2NvIFN5c3Rl
>
bXMxDDAKBgNVBAsTA1RBQzEaMBgGA1UEAxMRZnA0MTIwLnRlc3QubG9jYWwwggEi
>
MA0GCSqGSIb3DQEBAQUAA4IBDwAwggEKAoIBAQCzQ43mBqCR9nZ+LglUQA0b7tga
>
BwdudS3sulXIwKGco48mMHCRQw1ADWZCxFANxsnbfb+wrR8xKfKo4vwnMLuK3F5U
>
RlHLPv9rHtYY296D9c/7N3Tee3gZczrcWys9w+YDsTCCoNIuhKG0ERXXSGF/j43D
>
ikoJn55JKRImRMHVkdopX1u21iDeR/9QRRSCT8TKtWrcH67YOyig9WrvqZObwHBg
>
yodskS/g+a5GNYTzzIS9XAfslMSKP06/Ftq2MONVIkdkFRG0Jqe/IG8a4s/9D82a
>
/cujcb0hNssvmAhhlVq1PGnodNR7MfYwgjM5q9Tp3W0H2ufLGAa2Hl09XR2FAgMB
>
AAGjggJYMIICVDAcBgNVHREEFTATghFmcDQxMjAudGVzdC5sb2NhbDAdBgNVHQ4E
>
FgQU/1WpstiEYExs8DlZWcuHZwPtu5QwHwYDVR0jBBgwFoAUyInbDHPrFwEEBcbx
>
GSgQW7pOVIkwgdwGA1UdHwSB1DCB0TCBzqCBy6CByIaBxWxkYXA6Ly8vQ049bmFh
>
dXN0aW4tTkFBVVNUSU4tUEMtQ0EsQ049bmFhdXN0aW4tcGMsQ049Q0RQLENOPVB1
>
YmxpYyUyMEtleSUyMFNlcnZpY2VzLENOPVNlcnZpY2VzLENOPUNvbmZpZ3VyYXRp
>
b24sREM9bmFhdXN0aW4sREM9bG9jYWw/Y2VydGlmaWNhdGVSZXZvY2F0aW9uTGlz
>
dD9iYXNlP29iamVjdENsYXNzPWNSTERpc3RyaWJ1dGlvblBvaW50MIHMBggrBgEF
>
BQcBAQSBvzCBvDCBuQYIKwYBBQUHMAKGgaxsZGFwOi8vL0NOPW5hYXVzdGluLU5B
>
QVVTVElOLVBDLUNBLENOPUFJQSxDTj1QdWJsaWMlMjBLZXklMjBTZXJ2aWNlcyxD
>
Tj1TZXJ2aWNlcyxDTj1Db25maWd1cmF0aW9uLERDPW5hYXVzdGluLERDPWxvY2Fs
>
P2NBQ2VydGlmaWNhdGU/YmFzZT9vYmplY3RDbGFzcz1jZXJ0aWZpY2F0aW9uQXV0
>
aG9yaXR5MCEGCSsGAQQBgjcUAgQUHhIAVwBlAGIAUwBlAHIAdgBlAHIwDgYDVR0P
>
AQH/BAQDAgWgMBMGA1UdJQQMMAoGCCsGAQUFBwMBMAoGCCqGSM49BAMCA0gAMEUC
>
IFew7NcJirEtFRvyxjkQ4/dVo2oI6CRB308WQbYHNUu/AiEA7UdObiSJBG/PBZjm
>
sgoIK60akbjotOTvUdUd9b6K1Uw=
>
-----END CERTIFICATE-----
62
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Install a Trusted Identity Certificate
>
ENDOFBUF
Step 20
Exit the keyring mode:
exit
Step 21
Exit the security mode:
exit
Step 22
Enter the system mode:
scope system
Step 23
Enter the services mode:
scope services
Step 24
Configure the FXOS web service to use the new certificate:
set https keyring keyring_name
Step 25
Commit the configuration:
commit-buffer
Step 26
Display the keyring associated with the HTTPS server. It should reflect the keyring name created in step 3 of this procedure. If the screen output displays the default keyring name, the HTTPS server has not yet been updated to use the new certificate:
show https
Example:
fp4120 /system/services #
show https
Name: https
Admin State: Enabled
Port: 443
Operational port: 443
Key Ring:
firepower_cert
Cipher suite mode: Medium Strength
Cipher suite: ALL:!ADH:!EXPORT40:!EXPORT56:!LOW:!RC4:!MD5:!IDEA:+HIGH:+MEDIUM:+EXP:+eNULL
Step 27
Display the contents of the imported certificate, and verify that the
Certificate Status
value displays as
Valid
:
scope security
show keyring keyring_name detail
Example:
fp4120 /security #
scope security
fp4120 /security #
show keyring firepower_cert detail
Keyring firepower_cert:
RSA key modulus: Mod2048
Trustpoint CA: firepower_chain
Certificate status: Valid
Certificate:
Data:
Version: 3 (0x2)
Serial Number:
45:00:00:00:0a:de:86:55:16:82:24:f3:be:00:00:00:00:00:0a
Signature Algorithm: ecdsa-with-SHA256
Issuer: DC=local, DC=naaustin, CN=naaustin-NAAUSTIN-PC-CA
Validity
Not Before: Apr 28 13:09:54 2016 GMT
Not After : Apr 28 13:09:54 2018 GMT
Subject: C=US, ST=California, L=San Jose, O=Cisco Systems, OU=TAC,
CN=fp4120.test.local
Subject Public Key Info:
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
63
System Administration
Install a Trusted Identity Certificate
Public Key Algorithm: rsaEncryption
Public-Key: (2048 bit)
Modulus:
00:b3:43:8d:e6:06:a0:91:f6:76:7e:2e:09:54:40:
0d:1b:ee:d8:1a:07:07:6e:75:2d:ec:ba:55:c8:c0: a1:9c:a3:8f:26:30:70:91:43:0d:40:0d:66:42:c4:
50:0d:c6:c9:db:7d:bf:b0:ad:1f:31:29:f2:a8:e2: fc:27:30:bb:8a:dc:5e:54:46:51:cb:3e:ff:6b:1e: d6:18:db:de:83:f5:cf:fb:37:74:de:7b:78:19:73:
3a:dc:5b:2b:3d:c3:e6:03:b1:30:82:a0:d2:2e:84: a1:b4:11:15:d7:48:61:7f:8f:8d:c3:8a:4a:09:9f:
9e:49:29:12:26:44:c1:d5:91:da:29:5f:5b:b6:d6:
20:de:47:ff:50:45:14:82:4f:c4:ca:b5:6a:dc:1f: ae:d8:3b:28:a0:f5:6a:ef:a9:93:9b:c0:70:60:ca:
87:6c:91:2f:e0:f9:ae:46:35:84:f3:cc:84:bd:5c:
07:ec:94:c4:8a:3f:4e:bf:16:da:b6:30:e3:55:22:
47:64:15:11:b4:26:a7:bf:20:6f:1a:e2:cf:fd:0f: cd:9a:fd:cb:a3:71:bd:21:36:cb:2f:98:08:61:95:
5a:b5:3c:69:e8:74:d4:7b:31:f6:30:82:33:39:ab: d4:e9:dd:6d:07:da:e7:cb:18:06:b6:1e:5d:3d:5d:
1d:85
Exponent: 65537 (0x10001)
X509v3 extensions:
X509v3 Subject Alternative Name:
DNS:fp4120.test.local
X509v3 Subject Key Identifier:
FF:55:A9:B2:D8:84:60:4C:6C:F0:39:59:59:CB:87:67:03:ED:BB:94
X509v3 Authority Key Identifier: keyid:C8:89:DB:0C:73:EB:17:01:04:05:C6:F1:19:28:10:5B:BA:4E:54:89
X509v3 CRL Distribution Points:
Full Name:
URI:ldap:///CN=naaustin-NAAUSTIN-PC-CA,CN=naaustin-pc,CN=CDP,
CN=Public%20Key%20Services,CN=Services,CN=Configuration,DC=naaustin,
DC=local?certificateRevocationList?base?objectClass=cRLDistributionPoint
Authority Information Access:
CA Issuers - URI:ldap:///CN=naaustin-NAAUSTIN-PC-CA,CN=AIA,
CN=Public%20Key%20Services,CN=Services,CN=Configuration,DC=naaustin,
DC=local?cACertificate?base?objectClass=certificationAuthority
1.3.6.1.4.1.311.20.2:
...W.e.b.S.e.r.v.e.r
X509v3 Key Usage: critical
Digital Signature, Key Encipherment
X509v3 Extended Key Usage:
TLS Web Server Authentication
Signature Algorithm: ecdsa-with-SHA256
30:45:02:20:57:b0:ec:d7:09:8a:b1:2d:15:1b:f2:c6:39:10: e3:f7:55:a3:6a:08:e8:24:41:df:4f:16:41:b6:07:35:4b:bf:
02:21:00:ed:47:4e:6e:24:89:04:6f:cf:05:98:e6:b2:0a:08:
2b:ad:1a:91:b8:e8:b4:e4:ef:51:d5:1d:f5:be:8a:d5:4c
-----BEGIN CERTIFICATE-----
MIIE8DCCBJagAwIBAgITRQAAAArehlUWgiTzvgAAAAAACjAKBggqhkjOPQQDAjBT
MRUwEwYKCZImiZPyLGQBGRYFbG9jYWwxGDAWBgoJkiaJk/IsZAEZFghuYWF1c3Rp bjEgMB4GA1UEAxMXbmFhdXN0aW4tTkFBVVNUSU4tUEMtQ0EwHhcNMTYwNDI4MTMw
OTU0WhcNMTgwNDI4MTMwOTU0WjB3MQswCQYDVQQGEwJVUzETMBEGA1UECBMKQ2Fs aWZvcm5pYTERMA8GA1UEBxMIU2FuIEpvc2UxFjAUBgNVBAoTDUNpc2NvIFN5c3Rl bXMxDDAKBgNVBAsTA1RBQzEaMBgGA1UEAxMRZnA0MTIwLnRlc3QubG9jYWwwggEi
MA0GCSqGSIb3DQEBAQUAA4IBDwAwggEKAoIBAQCzQ43mBqCR9nZ+LglUQA0b7tga
BwdudS3sulXIwKGco48mMHCRQw1ADWZCxFANxsnbfb+wrR8xKfKo4vwnMLuK3F5U
RlHLPv9rHtYY296D9c/7N3Tee3gZczrcWys9w+YDsTCCoNIuhKG0ERXXSGF/j43D ikoJn55JKRImRMHVkdopX1u21iDeR/9QRRSCT8TKtWrcH67YOyig9WrvqZObwHBg yodskS/g+a5GNYTzzIS9XAfslMSKP06/Ftq2MONVIkdkFRG0Jqe/IG8a4s/9D82a
/cujcb0hNssvmAhhlVq1PGnodNR7MfYwgjM5q9Tp3W0H2ufLGAa2Hl09XR2FAgMB
AAGjggJYMIICVDAcBgNVHREEFTATghFmcDQxMjAudGVzdC5sb2NhbDAdBgNVHQ4E
FgQU/1WpstiEYExs8DlZWcuHZwPtu5QwHwYDVR0jBBgwFoAUyInbDHPrFwEEBcbx
GSgQW7pOVIkwgdwGA1UdHwSB1DCB0TCBzqCBy6CByIaBxWxkYXA6Ly8vQ049bmFh dXN0aW4tTkFBVVNUSU4tUEMtQ0EsQ049bmFhdXN0aW4tcGMsQ049Q0RQLENOPVB1
YmxpYyUyMEtleSUyMFNlcnZpY2VzLENOPVNlcnZpY2VzLENOPUNvbmZpZ3VyYXRp b24sREM9bmFhdXN0aW4sREM9bG9jYWw/Y2VydGlmaWNhdGVSZXZvY2F0aW9uTGlz dD9iYXNlP29iamVjdENsYXNzPWNSTERpc3RyaWJ1dGlvblBvaW50MIHMBggrBgEF
BQcBAQSBvzCBvDCBuQYIKwYBBQUHMAKGgaxsZGFwOi8vL0NOPW5hYXVzdGluLU5B
QVVTVElOLVBDLUNBLENOPUFJQSxDTj1QdWJsaWMlMjBLZXklMjBTZXJ2aWNlcyxD
64
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Recovering from a Software Failure
Tj1TZXJ2aWNlcyxDTj1Db25maWd1cmF0aW9uLERDPW5hYXVzdGluLERDPWxvY2Fs
P2NBQ2VydGlmaWNhdGU/YmFzZT9vYmplY3RDbGFzcz1jZXJ0aWZpY2F0aW9uQXV0 aG9yaXR5MCEGCSsGAQQBgjcUAgQUHhIAVwBlAGIAUwBlAHIAdgBlAHIwDgYDVR0P
AQH/BAQDAgWgMBMGA1UdJQQMMAoGCCsGAQUFBwMBMAoGCCqGSM49BAMCA0gAMEUC
IFew7NcJirEtFRvyxjkQ4/dVo2oI6CRB308WQbYHNUu/AiEA7UdObiSJBG/PBZjm sgoIK60akbjotOTvUdUd9b6K1Uw=
-----END CERTIFICATE-----
Zeroized: No
What to Do Next
To verify that the new trusted certificate is presented, navigate to the Firepower Chassis Manager by entering
https://<FQDN_or_IP>/
in the address bar of a web browser.
Note
Browsers also verify the subject-name of a certificate against the input in the address bar. If the certificate is issued to the fully qualified domain name, it must be accessed that way in the browser. If it is accessed via IP address, a different SSL error is thrown (Common Name Invalid) even if the trusted certificate is used.
Recovering from a Software Failure
Before You Begin
In the event of software failure that prevents the system from booting successfully, you can use the following procedure to boot a new version of software. To complete this process you need to TFTP boot a kickstart image, download new system and manager images, and then boot using the new images.
The recovery images for a specific FXOS version can be obtained from Cisco.com at one of the following locations:
•
Firepower 9300
— https://software.cisco.com/portal/pub/download/portal/ select.html?&mdfid=286287252&flowid=77282&softwareid=286287263
•
Firepower 4100 Series
— https://software.cisco.com/portal/pub/download/portal/ select.html?&mdfid=286305187&flowid=79423&softwareid=286287263
The recovery images include three separate files. For example, below are the current recovery images for
FXOS 2.1.1.64.
Recovery image (kickstart) for FX-OS 2.1.1.64.
fxos-k9-kickstart.5.0.3.N2.4.11.63.SPA
Recovery image (manager) for FX-OS 2.1.1.64.
fxos-k9-manager.4.1.1.63.SPA
Recovery image (system) for FX-OS 2.1.1.64.
fxos-k9-system.5.0.3.N2.4.11.63.SPA
Procedure
Step 1
Access ROMMON:
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
65
System Administration
Recovering from a Software Failure
a) Connect to the console port.
b) Reboot the system.
The system will start loading and during the process display a countdown timer.
c) Press the
Escape
key during the countdown to enter ROMMON mode.
Example:
Cisco System ROMMON, version 1.0.09, RELEASE SOFTWARE
Copright (c) 1994-2015 by Cisco Systems, Inc.
Compiled Sun 01/01/1999 23:59:59:59.99 by user
Current image running: Boot ROM0
Last reset cause: LocalSoft
DIMM Slot 0 : Present
DIMM Slot 1 : Present
No USB drive !!
Platform FPR9K-SUP with 16384 Mbytes of main memory
MAC Address aa:aa:aa:aa:aa:aa find the string ! boot bootflash:/installables/switch/fxos-k9-kickstart.5.0.3.N2.0.00.00.SPA
bootflash:/installables/switch/fxos-k9-system.5.0.3.N2.0.00.00.SPA
Use BREAK, ESC or CTRL+L to interrupt boot.
use SPACE to begin boot immediately.
Boot interrupted.
rommon 1 >
Step 2
TFTP boot a kickstart image: a) Verify that the management IP address, management netmask, and gateway IP address are set correctly.
You can see their values using the
set
command. You can test the connectivity to the TFTP server using the
ping
command.
rommon 1 >
set
ADDRESS=
NETMASK=
GATEWAY=
SERVER=
IMAGE=
PS1="ROMMON ! > " rommon > address <ip-address> rommon >
netmask <network-mask> rommon > gateway <default-gateway> b) Copy the kickstart image to a TFTP directory that is accessible from your FXOS chassis.
Note
The kickstart image version number will not match the bundle version number. Information showing the mapping between your FXOS version and the kickstart image can be found on the
Cisco.com software download page.
c) Boot the image from ROMMON using the boot command:
boot tftp://<IP address>/<path to image>
Note
You can also boot the kickstart from ROMMON using a USB media device inserted into the USB slot on the front panel of the FXOS chassis. If the USB device is inserted while the system is running, you will need to reboot the system before it will recognize the USB device.
The system will display a series of #'s indicating that the image is being received and will then load the kickstart image.
66
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Recovering from a Software Failure
Example:
rommon 1 >
set
ADDRESS=
NETMASK=
GATEWAY=
SERVER=
IMAGE=
PS1="ROMMON ! > " rommon 2 >
address 10.0.0.2
rommon 3 >
netmask 255.255.255.0
rommon 4 >
gateway 10.0.0.1
rommon 5 >
ping 10.0.0.2
..!!!!!!!!!!
Success rate is 100 percent (10/10) rommon 6 >
ping 192.168.1.2
..!!!!!!!!!!
Success rate is 100 percent (10/10) rommon 7 >
boot tftp://192.168.1.2/fxos-k9-kickstart.5.0.3.N2.1.11.1.SPA
ADDRESS: 10.0.0.2
NETMASK: 255.255.255.0
GATEWAY: 10.0.0.1
SERVER: 192.168.1.2
IMAGE: fxos-k9-kickstart.5.0.3.N2.1.11.1.SPA
TFTP_MACADDR: aa:aa:aa:aa:aa:aa
............................................................................
Receiving fxos-k9-kickstart.5.0.3.N2.1.11.1.SPA from 192.168.1.2
###############################################################################
###############################################################################
#############################################################################
File reception completed.
Step 3
Download the recovery system and manager images that match the kickstart image you just loaded to the
FXOS chassis: a) To download the recovery system and manager images you will need to set the management IP address and gateway. You cannot download these images via USB.
switch(boot)#
config terminal
switch(boot)(config)#
interface mgmt 0
switch(boot)(config-if)# ip address <ip address> <netmask> switch(boot)(config-if)#
no shutdown
switch(boot)(config-if)#
exit
switch(boot)(config)# ip default-gateway <gateway> switch(boot)(config)#
exit
b) Copy the recovery system and manager images from the remote server to the bootflash: switch(boot)#
copy URL bootflash:
Specify the URL for the file being imported using one of the following syntax:
•
ftp
://
username
@
hostname
/
path
/
image_name
•
scp
://
username
@
hostname
/
path
/
image_name
•
sftp
://
username
@
hostname
/
path
/
image_name
•
tftp
://
hostname
/
path
/
image_name
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
67
System Administration
Recovering from a Software Failure
Example:
switch(boot)#
copy scp://<username>@192.168.1.2/recovery_images/fxos-k9-system.5.0.3.N2.4.11.69.SPA
bootflash:
switch(boot)#
copy scp://<username>@192.168.1.2/recovery_images/fxos-k9-manager.4.1.1.69.SPA
bootflash:
c) After the images have been successfully copied to the FXOS chassis, make a symlink to the manager image from nuova-sim-mgmt-nsg.0.1.0.001.bin. This link tells the load mechanism which manager image to load. The symlink name should always be nuova-sim-mgmt-nsg.0.1.0.001.bin regardless of what image you are trying to load.
switch(boot)# copy bootflash:<manager-image>
bootflash:nuova-sim-mgmt-nsg.0.1.0.001.bin
Example:
switch(boot)#
config terminal
Enter configuration commands, one per line.
End with CNTL/Z.
switch(boot)(config)#
interface mgmt 0
switch(boot)(config-if)#
ip address 10.0.0.2 255.255.255.0
switch(boot)(config-if)#
no shutdown
switch(boot)(config-if)#
exit
switch(boot)(config)#
ip default-gateway 10.0.0.1
switch(boot)(config)#
exit
switch(boot)#
copy tftp://192.168.1.2/recovery_images/fxos-k9-system.5.0.3.N2.4.11.69.SPA
bootflash:
Trying to connect to tftp server......
Connection to server Established. Copying Started.....
/
TFTP get operation was successful
Copy complete, now saving to disk (please wait)...
switch(boot)#
copy tftp://192.168.1.2/recovery_images/fxos-k9-manager.4.1.1.69.SPA
bootflash:
Trying to connect to tftp server......
Connection to server Established. Copying Started.....
/
TFTP get operation was successful
Copy complete, now saving to disk (please wait)...
switch(boot)#
copy bootflash:fxos-k9-manager.4.1.1.69.SPA
bootflash:nuova-sim-mgmt-nsg.0.1.0.001.bin
Copy complete, now saving to disk (please wait)...
switch(boot)#
Step 4
Load the system image that you just downloaded: switch(boot)# load bootflash:<system-image>
Example:
switch(boot)# load bootflash:fxos-k9-system.5.0.3.N2.4.11.69.SPA
Uncompressing system image: bootflash:/fxos-k9-system.5.0.3.N2.4.11.69.SPA
Manager image digital signature verification successful
...
68
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Recovering from a Corrupted File System
System is coming up ... Please wait ...
Cisco FPR Series Security Appliance
FP9300-A login:
Step 5
After the recovery images have loaded, enter the following commands to prevent the system from trying to load the prior images:
Note
This step should be performed immediately after loading the recovery images.
FP9300-A#
scope org
FP9300-A /org #
scope fw-platform-pack default
FP9300-A /org/fw-platform-pack #
set platform-bundle-version ""
Warning: Set platform version to empty will result software/firmware incompatibility issue.
FP9300-A /org/fw-platform-pack* #
commit-buffer
Step 6
Download and install the Platform Bundle image that you want to use on your FXOS chassis. For more information, see
.
Example:
FP9300-A# scope firmware
FP9300-A /firmware # show download-task
Download task:
File Name Protocol Server Port Userid State
--------- -------- --------------- ---------- --------------- ----fxos-k9.2.1.1.73.SPA
Tftp 192.168.1.2
0 Downloaded
FP9300-A /firmware # show package fxos-k9.2.1.1.73.SPA detail
Firmware Package fxos-k9.2.1.1.73.SPA:
Version: 2.1(1.73)
Type: Platform Bundle
State: Active
Time Stamp: 2012-01-01T07:40:28.000
Build Date: 2017-02-28 13:51:08 UTC
FP9300-A /firmware #
Recovering from a Corrupted File System
Before You Begin
If the Supervisor ’ s onboard flash becomes corrupted and the system is no longer able to start successfully, you can use the following procedure to recover the system. To complete this process you need to TFTP boot a kickstart image, reformat the flash, download new system and manager images, and then boot using the new images.
Note
This procedure includes reformatting the system flash. As a result, you will need to completely reconfigure your system after it has been recovered.
The recovery images for a specific FXOS version can be obtained from Cisco.com at one of the following locations:
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
69
System Administration
Recovering from a Corrupted File System
• Firepower 9300 — https://software.cisco.com/portal/pub/download/portal/ select.html?&mdfid=286287252&flowid=77282&softwareid=286287263
• Firepower 4100 Series — https://software.cisco.com/portal/pub/download/portal/ select.html?&mdfid=286305187&flowid=79423&softwareid=286287263
The recovery images include three separate files. For example, below are the recovery images for FXOS
2.1.1.64.
Recovery image (kickstart) for FX-OS 2.1.1.64.
fxos-k9-kickstart.5.0.3.N2.4.11.63.SPA
Recovery image (manager) for FX-OS 2.1.1.64.
fxos-k9-manager.4.1.1.63.SPA
Recovery image (system) for FX-OS 2.1.1.64.
fxos-k9-system.5.0.3.N2.4.11.63.SPA
Procedure
Step 1
Access ROMMON: a) Connect to the console port.
b) Reboot the system.
The system will start loading and during the process display a countdown timer.
c) Press the
Escape
key during the countdown to enter ROMMON mode.
Example:
Cisco System ROMMON, version 1.0.09, RELEASE SOFTWARE
Copright (c) 1994-2015 by Cisco Systems, Inc.
Compiled Sun 01/01/1999 23:59:59:59.99 by user
Current image running: Boot ROM0
Last reset cause: LocalSoft
DIMM Slot 0 : Present
DIMM Slot 1 : Present
No USB drive !!
Platform FPR9K-SUP with 16384 Mbytes of main memory
MAC Address aa:aa:aa:aa:aa:aa find the string ! boot bootflash:/installables/switch/fxos-k9-kickstart.5.0.3.N2.0.00.00.SPA
bootflash:/installables/switch/fxos-k9-system.5.0.3.N2.0.00.00.SPA
Use BREAK, ESC or CTRL+L to interrupt boot.
use SPACE to begin boot immediately.
Boot interrupted.
rommon 1 >
Step 2
TFTP boot a kickstart image: a) Verify that the management IP address, management netmask, and gateway IP address are set correctly.
You can see their values using the
set
command. You can test the connectivity to the TFTP server using the
ping
command.
rommon 1 >
set
ADDRESS=
NETMASK=
GATEWAY=
SERVER=
70
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Recovering from a Corrupted File System
IMAGE=
PS1="ROMMON ! > " rommon > address <ip-address> rommon > netmask <network-mask> rommon >
gateway <default-gateway> b) Copy the kickstart image to a TFTP directory that is accessible from your FXOS chassis.
Note
The kickstart image version number will not match the bundle version number. Information showing the mapping between your FXOS version and the kickstart image can be found on the
Cisco.com software download page.
c) Boot the image from ROMMON using the boot command:
boot tftp://<IP address>/<path to image>
Note
You can also boot the kickstart from ROMMON using a USB media device inserted into the USB slot on the front panel of the FXOS chassis. If the USB device is inserted while the system is running, you will need to reboot the system before it will recognize the USB device.
The system will display a series of #'s indicating that the image is being received and will then load the kickstart image.
Example:
rommon 1 >
set
ADDRESS=
NETMASK=
GATEWAY=
SERVER=
IMAGE=
PS1="ROMMON ! > " rommon 2 >
address 10.0.0.2
rommon 3 >
netmask 255.255.255.0
rommon 4 >
gateway 10.0.0.1
rommon 5 >
ping 10.0.0.2
..!!!!!!!!!!
Success rate is 100 percent (10/10) rommon 6 >
ping 192.168.1.2
..!!!!!!!!!!
Success rate is 100 percent (10/10) rommon 7 >
boot tftp://192.168.1.2/fxos-k9-kickstart.5.0.3.N2.1.11.1.SPA
ADDRESS: 10.0.0.2
NETMASK: 255.255.255.0
GATEWAY: 10.0.0.1
SERVER: 192.168.1.2
IMAGE: fxos-k9-kickstart.5.0.3.N2.1.11.1.SPA
TFTP_MACADDR: aa:aa:aa:aa:aa:aa
............................................................................
Receiving fxos-k9-kickstart.5.0.3.N2.1.11.1.SPA from 192.168.1.2
###############################################################################
###############################################################################
#############################################################################
File reception completed.
Step 3
After the kickstart image has loaded, reformat the flash using the
init system
command.
The
init system
command erases the contents of the flash including all software images downloaded to the system and all configurations on the system. The command takes approximately 20-30 minutes to complete.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
71
System Administration
Recovering from a Corrupted File System
Example:
switch(boot)# init system
This command is going to erase your startup-config, licenses as well as the contents of your bootflash:.
Do you want to continue? (y/n) [n] y
Detected 32GB flash...
Initializing the system mke2fs 1.35 (28-Feb-2004)
Checking for bad blocks (read-only test):
Initializing startup-config and licenses mke2fs 1.35 (28-Feb-2004)
Checking for bad blocks (read-only test): mke2fs 1.35 (28-Feb-2004)
Checking for bad blocks (read-only test): mke2fs 1.35 (28-Feb-2004)
Checking for bad blocks (read-only test):
Formatting bootflash: mke2fs 1.35 (28-Feb-2004)
Checking for bad blocks (read-only test):
Formatting SAM partition: mke2fs 1.35 (28-Feb-2004)
Checking for bad blocks (read-only test):
Formatting Workspace partition: mke2fs 1.35 (28-Feb-2004)
Checking for bad blocks (read-only test):
Formatting Sysdebug partition: mke2fs 1.35 (28-Feb-2004)
Checking for bad blocks (read-only test): done done done done done done done done
Step 4
Download the recovery images to the FXOS chassis: a) To download the recovery images you will need to set the management IP address and gateway. You cannot download these images via USB.
switch(boot)#
config terminal
switch(boot)(config)#
interface mgmt 0
switch(boot)(config-if)# ip address <ip address> <netmask> switch(boot)(config-if)#
no shutdown
switch(boot)(config-if)#
exit
switch(boot)(config)# ip default-gateway <gateway> switch(boot)(config)#
exit
b) Copy all three recovery images from the remote server to the bootflash: switch(boot)#
copy URL bootflash:
Specify the URL for the file being imported using one of the following syntax:
•
ftp
://
username
@
hostname
/
path
/
image_name
•
scp
://
username
@
hostname
/
path
/
image_name
•
sftp
://
username
@
hostname
/
path
/
image_name
•
tftp
://
hostname
/
path
/
image_name
Example:
switch(boot)#
copy scp://<username>@192.168.1.2/recovery_images/fxos-k9-kickstart.5.0.3.N2.4.11.69.SPA
bootflash:
72
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Recovering from a Corrupted File System
switch(boot)#
copy scp://<username>@192.168.1.2/recovery_images/fxos-k9-system.5.0.3.N2.4.11.69.SPA
bootflash:
switch(boot)#
copy scp://<username>@192.168.1.2/recovery_images/fxos-k9-manager.4.1.1.69.SPA
bootflash:
c) After the images have been successfully copied to the FXOS chassis, make a symlink to the manager image from nuova-sim-mgmt-nsg.0.1.0.001.bin. This link tells the load mechanism which manager image to load. The symlink name should always be nuova-sim-mgmt-nsg.0.1.0.001.bin regardless of what image you are trying to load.
switch(boot)#
copy bootflash:<manager-image>
bootflash:nuova-sim-mgmt-nsg.0.1.0.001.bin
Example:
switch(boot)#
config terminal
Enter configuration commands, one per line.
End with CNTL/Z.
switch(boot)(config)#
interface mgmt 0
switch(boot)(config-if)#
ip address 10.0.0.2 255.255.255.0
switch(boot)(config-if)#
no shutdown
switch(boot)(config-if)#
exit
switch(boot)(config)#
ip default-gateway 10.0.0.1
switch(boot)(config)#
exit
switch(boot)#
copy tftp://192.168.1.2/recovery_images/fxos-k9-kickstart.5.0.3.N2.4.11.69.SPA
bootflash:
Trying to connect to tftp server......
Connection to server Established. Copying Started.....
/
TFTP get operation was successful
Copy complete, now saving to disk (please wait)...
switch(boot)#
copy tftp://192.168.1.2/recovery_images/fxos-k9-system.5.0.3.N2.4.11.69.SPA
bootflash:
Trying to connect to tftp server......
Connection to server Established. Copying Started.....
/
TFTP get operation was successful
Copy complete, now saving to disk (please wait)...
switch(boot)#
copy tftp://192.168.1.2/recovery_images/fxos-k9-manager.4.1.1.69.SPA
bootflash:
Trying to connect to tftp server......
Connection to server Established. Copying Started.....
/
TFTP get operation was successful
Copy complete, now saving to disk (please wait)...
switch(boot)#
copy bootflash:fxos-k9-manager.4.1.1.69.SPA
bootflash:nuova-sim-mgmt-nsg.0.1.0.001.bin
Copy complete, now saving to disk (please wait)...
switch(boot)#
Step 5
Reload the switch: switch(boot)#
reload
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
73
System Administration
Recovering from a Corrupted File System
Example:
switch(boot)#
reload
This command will reboot this supervisor module. (y/n) ?
y
[ 1866.310313] Restarting system.
!!
Rommon image verified successfully !!
Cisco System ROMMON, Version 1.0.11, RELEASE SOFTWARE
Copyright (c) 1994-2016 by Cisco Systems, Inc.
Compiled Wed 11/23/2016 11:23:23.47 by builder
Current image running: Boot ROM1
Last reset cause: ResetRequest
DIMM Slot 0 : Present
DIMM Slot 1 : Present
No USB drive !!
BIOS has been locked !!
Platform FPR9K-SUP with 16384 Mbytes of main memory
MAC Address: bb:aa:77:aa:aa:bb autoboot: Can not find autoboot file 'menu.lst.local'
Or can not find correct boot string !!
rommon 1 >
Step 6
Boot from the kickstart and system images: rommon 1 > boot <kickstart-image> <system-image>
Note
You will likely see license manager failure messages while the system image is loading. These messages can be safely ignored.
Example:
rommon 1 > dir
Directory of: bootflash:\
01/01/12 12:33a <DIR>
01/01/12 12:33a <DIR>
01/01/12 12:16a <DIR>
01/01/12 12:27a
4,096 .
4,096 ..
16,384 lost+found
34,333,696 fxos-k9-kickstart.5.0.3.N2.4.11.69.SPA
01/01/12 12:29a
01/01/12 12:31a
330,646,465 fxos-k9-manager.4.1.1.69.SPA
250,643,172 fxos-k9-system.5.0.3.N2.4.11.69.SPA
01/01/12 12:34a 330,646,465 nuova-sim-mgmt-nsg.0.1.0.001.bin
4 File(s) 946,269,798 bytes
3 Dir(s) rommon 2 > boot fxos-k9-kickstart.5.0.3.N2.4.11.69.SPA fxos-k9-system.5.0.3.N2.4.11.69.SPA
!!
Kickstart Image verified successfully !!
Linux version: 2.6.27.47 ([email protected]) #1 SMP Thu Nov 17 18:22:00 PST 2016
[ 0.000000] Fastboot Memory at 0c100000 of size 201326592
Usage: init 0123456SsQqAaBbCcUu
INIT: version 2.86 booting
POST INIT Starts at Sun Jan 1 00:27:32 UTC 2012
S10mount-ramfs.supnuovaca Mounting /isan 3000m
Mounted /isan
Creating /callhome..
Mounting /callhome..
Creating /callhome done.
Callhome spool file system init done.
Platform is BS or QP MIO: 30
FPGA Version 0x00010500 FPGA Min Version 0x00000600
Checking all filesystems..r.r..r done.
Warning: switch is starting up with default configuration
Checking NVRAM block device ... done
.
74
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Recovering from a Corrupted File System
FIPS power-on self-test passed
Unpack CMC Application software
Loading system software
Uncompressing system image: bootflash:/fxos-k9-system.5.0.3.N2.4.11.69.SPA
Manager image digital signature verification successful
...
System is coming up ... Please wait ...
nohup: appending output to `nohup.out'
---- Basic System Configuration Dialog ----
This setup utility will guide you through the basic configuration of the system. Only minimal configuration including IP connectivity to the Fabric interconnect and its clustering mode is performed through these steps.
Type Ctrl-C at any time to abort configuration and reboot system.
To back track or make modifications to already entered values, complete input till end of section and answer no when prompted to apply configuration.
You have chosen to setup a new Security Appliance. Continue? (y/n):
Step 7
After the images have loaded, the system will prompt you to enter initial configuration settings. For more information, see
Initial Configuration, on page 6
.
Step 8
Download the Platform Bundle image that you want to use on your FXOS chassis. The Platform Bundle image version should correspond with the images you used for recovering your system. For more information, see
.
Example:
FP9300-A# scope firmware
FP9300-A /firmware # show download-task
Download task:
File Name Protocol Server Port Userid State
--------- -------- --------------- ---------- --------------- ----fxos-k9.2.1.1.73.SPA
Downloaded Tftp 192.168.1.2
0
FP9300-A /firmware # show package fxos-k9.2.1.1.73.SPA detail
Firmware Package fxos-k9.2.1.1.73.SPA:
Version: 2.1(1.73)
Type: Platform Bundle
State: Active
Time Stamp: 2012-01-01T07:40:28.000
Build Date: 2017-02-28 13:51:08 UTC
FP9300-A /firmware #
Step 9
After the Platform Bundle has been successfully downloaded, you must manually activate the kickstart and system images so that they will be used when loading the system in the future. Automatic activation does not occur when using this procedure to recover from a corrupted file system because the running version matches the proposed startup version.
a) Set the scope for fabric-interconnect a:
FP9300-A#
scope fabric-interconnect a
b) Use the
show version
command to view the running kernel version and the running system version. You will use these strings to activate the images.
FP9300-A /fabric-interconnect #
show version
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
75
System Administration
Recovering from a Corrupted File System
c) Enter the following command to activate the images:
FP9300-A /fabric-interconnect #
activate firmware
kernel-version <running_kernel_version> system-version <running_system_version> commit-buffer
Note
The server status might change to "Disk Failed." You do not need to worry about this message and can continue with this procedure.
d) Use the
show version
command to verify that the startup versions have been set correctly and to monitor the activation status for the images.
Important
Do not proceed to the next step until the status changes from "Activating" to "Ready."
FP9300-A /fabric-interconnect #
show version
Example:
FP9300-A /firmware #
top
FP9300-A#
scope fabric-interconnect a
FP9300-A /fabric-interconnect #
show version
Fabric Interconnect A:
Running-Kern-Vers: 5.0(3)N2(4.11.69)
Running-Sys-Vers: 5.0(3)N2(4.11.69)
Package-Vers: 2.1(1.73)
Startup-Kern-Vers:
Startup-Sys-Vers:
Act-Kern-Status: Ready
Act-Sys-Status: Ready
Bootloader-Vers:
FP9300-A /fabric-interconnect #
activate firmware kernel-version
5.0(3)N2(4.11.69) system-version 5.0(3)N2(4.11.69)
Warning: When committed this command will reset the end-point
FP9300-A /fabric-interconnect* #
commit-buffer
FP9300-A /fabric-interconnect #
show version
Fabric Interconnect A:
Running-Kern-Vers: 5.0(3)N2(4.11.69)
Running-Sys-Vers: 5.0(3)N2(4.11.69)
Package-Vers: 2.1(1.73)
Startup-Kern-Vers: 5.0(3)N2(4.11.69)
Startup-Sys-Vers: 5.0(3)N2(4.11.69)
Act-Kern-Status: Activating
Act-Sys-Status: Activating
Bootloader-Vers:
FP9300-A /fabric-interconnect #
show version
Fabric Interconnect A:
Running-Kern-Vers: 5.0(3)N2(4.11.69)
Running-Sys-Vers: 5.0(3)N2(4.11.69)
Package-Vers: 2.1(1.73)
Startup-Kern-Vers: 5.0(3)N2(4.11.69)
Startup-Sys-Vers: 5.0(3)N2(4.11.69)
Act-Kern-Status: Ready
Act-Sys-Status: Ready
Bootloader-Vers:
Step 10
Reboot the system:
Example:
FP9300-A /fabric-interconnect #
top
FP9300-A#
scope chassis 1
FP9300-A /chassis #
reboot no-prompt
Starting chassis reboot. Monitor progress with the command "show fsm status"
FP9300-A /chassis #
76
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
System Administration
Recovering from a Corrupted File System
The system will power down each security module/engine before finally powering down and then restarting the FXOS chassis. This process takes approximately 5-10 minutes.
Step 11
Monitor the system status. The server status should go from "Discovery" to "Config" and then finally to "Ok".
Example:
FP9300-A#
show server status
Server Slot Status Overall Status Discovery
------- --------------------------------- --------------------- ---------
1/1
1/2
1/3
Equipped
Equipped
Empty
Discovery
Discovery
In Progress
In Progress
FP9300-A#
show server status
Server
1/2
1/3
Slot Status
Equipped
Empty
Overall Status Discovery
------- --------------------------------- --------------------- ---------
1/1 Equipped Config Complete
Config Complete
FP9300-A#
show server status
Server Slot Status Overall Status Discovery
------- --------------------------------- --------------------- ---------
1/1
1/2
1/3
Equipped
Equipped
Empty
Ok
Ok
Complete
Complete
When the Overall Status is "Ok" your system has been recovered. You must still reconfigure your security appliance (including license configuration) and re-create any logical devices. For more information:
• Firepower 9300 Quick Start Guides — http://www.cisco.com/go/firepower9300-quick
•
Firepower 9300 Configuration Guides
— http://www.cisco.com/go/firepower9300-config
•
Firepower 4100 Series Quick Start Guides
— http://www.cisco.com/go/firepower4100-quick
• Firepower 4100 Series Configuration Guides — http://www.cisco.com/go/firepower4100-config
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
77
Recovering from a Corrupted File System
System Administration
78
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
8
Platform Settings
•
Setting the Date and Time, page 79
•
•
•
•
•
•
•
Configuring DNS Servers, page 111
Setting the Date and Time
Use the NTP page to configure the network time protocol (NTP) on the system, to set the date and time manually, or to view the current system time.
NTP settings are automatically synced between the FXOS chassis and any logical devices installed on the chassis.
Note
If you are deploying Firepower Threat Defense on the FXOS chassis, you must configure NTP on the
FXOS chassis so that Smart Licensing will work properly and to ensure proper timestamps on device registrations. You should use the same NTP server for the FXOS chassis and the Firepower Management
Center.
If you are using NTP, you can view the overall synchronization status on the
Current Time
tab, or you can view the synchronization status for each configured NTP server by looking at the Server Status field in the
NTP Server
table on the
Time Synchronization
tab. If the system is unable to synchronize with a particular
NTP server, you can hover over the information icon next to the Server Status for more information.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
79
Platform Settings
Viewing the Configured Date and Time
Viewing the Configured Date and Time
Procedure
Step 1
Choose
Platform Settings
>
NTP
.
Step 2
Click the
Current Time
tab.
The system shows the date, time, and time zone that are configured on the device.
If you are using NTP, you can also view the overall synchronization status on the
Current Time
tab. You can view the synchronization status for each configured NTP server by looking at the Server Status field in the
NTP Server
table on the
Time Synchronization
tab. If the system is unable to synchronize with a particular
NTP server, you can hover over the information icon next to the Server Status for more information.
Setting the Time Zone
Procedure
Step 1
Choose
Platform Settings
>
NTP
.
Step 2
Click the
Current Time
tab.
Step 3
Choose the appropriate time zone for the Firepower chassis from the
Time Zone
drop-down list.
Setting the Date and Time Using NTP
NTP is used to implement a hierarchical system of servers that provide a precisely synchronized time among network systems. This kind of accuracy is required for time-sensitive operations, such as validating CRLs, which include a precise time stamp. You can configure up to four NTP servers.
Procedure
Step 1
Choose
Platform Settings
>
NTP
.
Step 2
Click the
Time Synchronization
tab.
Step 3
Under
Set Time Source
, click
Use NTP Server
.
Step 4
For each NTP server you want to use, up to a maximum of four, enter the IP address or hostname of the NTP server in the
NTP Server
field and click
Add
.
Step 5
Click
Save
.
The Firepower chassis is configured with the NTP server information specified.
80
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Deleting an NTP Server
You can view the synchronization status of each server by looking at the Server Status field in the
NTP Server
table. If the system is unable to synchronize with a particular NTP server, you can hover over the information icon next to the Server Status for more information.
Note
If you modify the system time by more than 10 minutes, the system will log you out and you will need to log in to the Firepower Chassis Manager again.
Deleting an NTP Server
Procedure
Step 1
Choose
Platform Settings
>
NTP
.
Step 2
Click the
Time Synchronization
tab.
Step 3
For each NTP server that you want to remove, click the
Delete
icon for that server in the
NTP Server
table.
Step 4
Click
Save
.
Setting the Date and Time Manually
This section describes how to set the date and time manually on the Firepower chassis.
Procedure
Step 1
Choose
Platform Settings
>
NTP
.
Step 2
Click the
Time Synchronization
tab.
Step 3
Under
Set Time Source
, click
Set Time Manually
.
Step 4
Click the
Date
drop-down list to display a calendar and then set the date using the controls available in the calendar.
Step 5
Use the corresponding drop-down lists to specify the time as hours, minutes, and AM/PM.
Tip
You can click
Get System Time
to set the date and time to match what is configured on the system you are using to connect to the Firepower Chassis Manager.
Step 6
Click
Save
.
The Firepower chassis is configured with the date and time specified.
Note
If you modify the system time by more than 10 minutes, the system will log you out and you will need to log in to the Firepower Chassis Manager again.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
81
Platform Settings
Configuring SSH
Configuring SSH
The following procedure describes how to enable or disable SSH access to the Firepower chassis. SSH is enabled by default.
Procedure
Step 1
Choose
Platform Settings
>
SSH
.
Step 2
To enable SSH access to the Firepower chassis, check the
Enable SSH
check box. To disable SSH access, uncheck the
Enable SSH
check box.
Step 3
Click
Save
.
Configuring Telnet
The following procedure describes how to enable or disable Telnet access to the Firepower chassis. Telnet is disabled by default.
Note
Telnet configuration is currently only available using the CLI.
Procedure
Step 1
Enter system mode:
Firepower-chassis #
scope system
Step 2
Enter system services mode:
Firepower-chassis /system #
scope services
Step 3
To configure Telnet access to the Firepower chassis, do one of the following:
• To allow Telnet access to the Firepower chassis, enter the following command:
Firepower-chassis /system/services #
enable telnet-server
• To disallow Telnet access to the Firepower chassis, enter the following command:
Firepower-chassis /system/services #
disable telnet-server
Step 4
Commit the transaction to the system configuration:
Firepower /system/services #
commit-buffer
The following example enables Telnet and commits the transaction:
Firepower-chassis#
scope system
Firepower-chassis /system #
scope services
82
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Configuring SNMP
Firepower-chassis /services #
enable telnet-server
Firepower-chassis /services* #
commit-buffer
Firepower-chassis /services #
Configuring SNMP
Use the SNMP page to configure the Simple Network Management Protocol (SNMP) on the Firepower chassis.
See the following topics for more information:
About SNMP
The Simple Network Management Protocol (SNMP) is an application-layer protocol that provides a message format for communication between SNMP managers and agents. SNMP provides a standardized framework and a common language used for the monitoring and management of devices in a network.
The SNMP framework consists of three parts:
•
An SNMP manager
—
The system used to control and monitor the activities of network devices using
SNMP.
• An SNMP agent — The software component within the Firepower chassis that maintains the data for the
Firepower chassis and reports the data, as needed, to the SNMP manager. The Firepower chassis includes the agent and a collection of MIBs. To enable the SNMP agent and create the relationship between the manager and agent, enable and configure SNMP in the Firepower Chassis Manager or the FXOS CLI.
• A managed information base (MIB) — The collection of managed objects on the SNMP agent.
The Firepower chassis supports SNMPv1, SNMPv2c and SNMPv3. Both SNMPv1 and SNMPv2c use a community-based form of security. SNMP is defined in the following:
• RFC 3410 ( http://tools.ietf.org/html/rfc3410 )
•
RFC 3411 ( http://tools.ietf.org/html/rfc3411 )
•
RFC 3412 ( http://tools.ietf.org/html/rfc3412 )
• RFC 3413 ( http://tools.ietf.org/html/rfc3413 )
• RFC 3414 ( http://tools.ietf.org/html/rfc3414 )
•
RFC 3415 ( http://tools.ietf.org/html/rfc3415 )
•
RFC 3416 ( http://tools.ietf.org/html/rfc3416 )
• RFC 3417 ( http://tools.ietf.org/html/rfc3417 )
•
RFC 3418 ( http://tools.ietf.org/html/rfc3418 )
•
RFC 3584 ( http://tools.ietf.org/html/rfc3584 )
SNMP Notifications
A key feature of SNMP is the ability to generate notifications from an SNMP agent. These notifications do not require that requests be sent from the SNMP manager. Notifications can indicate improper user
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
83
Platform Settings
SNMP Security Levels and Privileges
authentication, restarts, the closing of a connection, loss of connection to a neighbor router, or other significant events.
The Firepower chassis generates SNMP notifications as either traps or informs. Traps are less reliable than informs because the SNMP manager does not send any acknowledgment when it receives a trap, and the
Firepower chassis cannot determine if the trap was received. An SNMP manager that receives an inform request acknowledges the message with an SNMP response protocol data unit (PDU). If the Firepower chassis does not receive the PDU, it can send the inform request again.
SNMP Security Levels and Privileges
SNMPv1, SNMPv2c, and SNMPv3 each represent a different security model. The security model combines with the selected security level to determine the security mechanism applied when the SNMP message is processed.
The security level determines the privileges required to view the message associated with an SNMP trap. The privilege level determines whether the message needs to be protected from disclosure or authenticated. The supported security level depends upon which security model is implemented. SNMP security levels support one or more of the following privileges:
• noAuthNoPriv
—
No authentication or encryption
• authNoPriv — Authentication but no encryption
• authPriv — Authentication and encryption
SNMPv3 provides for both security models and security levels. A security model is an authentication strategy that is set up for a user and the role in which the user resides. A security level is the permitted level of security within a security model. A combination of a security model and a security level determines which security mechanism is employed when handling an SNMP packet.
Supported Combinations of SNMP Security Models and Levels
The following table identifies what the combinations of security models and levels mean.
Table 5: SNMP Security Models and Levels
Model
v1
Level
noAuthNoPriv
Authentication
Community string
Encryption
No v2c v3 noAuthNoPriv noAuthNoPriv
Community string No
Username No
What Happens
Uses a community string match for authentication.
Uses a community string match for authentication.
Uses a username match for authentication.
84
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
SNMPv3 Security Features
Model
v3 v3
Level
authNoPriv
Authentication
HMAC-SHA
Encryption
No authPriv HMAC-SHA DES
What Happens
Provides authentication based on the HMAC
Secure Hash
Algorithm (SHA).
Provides authentication based on the HMAC-SHA algorithm. Provides
Data Encryption
Standard (DES)
56-bit encryption in addition to authentication based on the Cipher Block
Chaining (CBC)
DES (DES-56) standard.
SNMPv3 Security Features
SNMPv3 provides secure access to devices by a combination of authenticating and encrypting frames over the network. SNMPv3 authorizes management operations only by configured users and encrypts SNMP messages. The SNMPv3 User-Based Security Model (USM) refers to SNMP message-level security and offers the following services:
•
Message integrity
—
Ensures that messages have not been altered or destroyed in an unauthorized manner and that data sequences have not been altered to an extent greater than can occur non-maliciously.
•
Message origin authentication
—
Ensures that the claimed identity of the user on whose behalf received data was originated is confirmed.
• Message confidentiality and encryption — Ensures that information is not made available or disclosed to unauthorized individuals, entities, or processes.
SNMP Support
The Firepower chassis provides the following support for SNMP:
Support for MIBs
The Firepower chassis supports read-only access to MIBs.
Authentication Protocol for SNMPv3 Users
The Firepower chassis supports the HMAC-SHA-96 (SHA) authentication protocol for SNMPv3 users.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
85
Platform Settings
Enabling SNMP and Configuring SNMP Properties
AES Privacy Protocol for SNMPv3 Users
The Firepower chassis uses Advanced Encryption Standard (AES) as one of the privacy protocols for SNMPv3 message encryption and conforms with RFC 3826.
The privacy password, or priv option, offers a choice of DES or 128-bit AES encryption for SNMP security encryption. If you enable AES-128 configuration and include a privacy password for an SNMPv3 user, the
Firepower chassis uses the privacy password to generate a 128-bit AES key. The AES privacy password can have a minimum of eight characters. If the passphrases are specified in clear text, you can specify a maximum of 64 characters.
Enabling SNMP and Configuring SNMP Properties
Procedure
Step 1
Choose
Platform Settings
>
SNMP
.
Step 2
In the
SNMP
area, complete the following fields:
Name Description
Admin State
check box Whether SNMP is enabled or disabled. Enable this service only if your system includes integration with an SNMP server.
Port
field The port on which the Firepower chassis communicates with the SNMP host. You cannot change the default port.
Community/Username
field The default SNMP v1 or v2 community name or SNMP v3 username the Firepower chassis includes on any trap messages it sends to the
SNMP host.
Enter an alphanumeric string between 1 and 32 characters. Do not use
@ (at sign), \ (backslash), " (double quote), ? (question mark) or an empty space. The default is public.
Note that if the
Community/Username
field is already set, the text to the right of the empty field reads
Set: Yes
. If the
Community/Username
field is not yet populated with a value, the text to the right of the empty field reads
Set: No
.
System Administrator Name
field The contact person responsible for the SNMP implementation.
Enter a string of up to 255 characters, such as an email address or a name and telephone number.
Location
field The location of the host on which the SNMP agent (server) runs.
Enter an alphanumeric string up to 510 characters.
Step 3
Click
Save
.
86
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Creating an SNMP Trap
What to Do Next
Create SNMP traps and users.
Creating an SNMP Trap
Procedure
Step 1
Choose
Platform Settings
>
SNMP
.
Step 2
In the
SNMP Traps
area, click
Add
.
Step 3
In the
Add SNMP Trap
dialog box, complete the following fields:
Name Description
Host Name
field The hostname or IP address of the SNMP host to which the Firepower chassis should send the trap.
Community/Username
field
Port
field
The SNMP v1 or v2 community name or the SNMP v3 username the
Firepower chassis includes when it sends the trap to the SNMP host.
This must be the same as the community or username that is configured for the SNMP service.
Enter an alphanumeric string between 1 and 32 characters. Do not use
@ (at sign), \ (backslash), " (double quote), ? (question mark) or an empty space.
The port on which the Firepower chassis communicates with the SNMP host for the trap.
Enter an integer between 1 and 65535.
Version
field The SNMP version and model used for the trap. This can be one of the following:
•
V1
•
V2
•
V3
Type
field If you select
V2
or
V3
for the version, the type of trap to send. This can be one of the following:
•
Traps
•
Informs
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
87
Platform Settings
Deleting an SNMP Trap
Name v3 Privilege
field
Description
If you select
V3
for the version, the privilege associated with the trap.
This can be one of the following:
•
Auth
— Authentication but no encryption
•
Noauth
—
No authentication or encryption
•
Priv
—
Authentication and encryption
Step 4
Click
OK
to close the
Add SNMP Trap
dialog box.
Step 5
Click
Save
.
Deleting an SNMP Trap
Procedure
Step 1
Choose
Platform Settings
>
SNMP
.
Step 2
In the
SNMP Traps
area, click the
Delete
icon in the row in the table that corresponds to the trap you want to delete.
Creating an SNMPv3 User
Procedure
Step 1
Choose
Platform Settings
>
SNMP
.
Step 2
In the
SNMP Users
area, click
Add
.
Step 3
In the
Add SNMP User
dialog box, complete the following fields:
Name Description
Name
field The username assigned to the SNMP user.
Enter up to 32 letters or numbers. The name must begin with a letter and you can also specify _ (underscore), . (period), @ (at sign), and -
(hyphen).
Auth Type
field
Use AES-128
check box
The authorization type:
SHA
.
If checked, this user uses AES-128 encryption.
88
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Deleting an SNMPv3 User
Name
Password
field
Confirm Password
Privacy Password
field field
Description
The password for this user.
The password again for confirmation purposes.
The privacy password for this user.
Confirm Privacy Password
field The privacy password again for confirmation purposes.
Step 4
Click
OK
to close the
Add SNMP User
dialog box.
Step 5
Click
Save
.
Deleting an SNMPv3 User
Procedure
Step 1
Choose
Platform Settings
>
SNMP
.
Step 2
In the
SNMP Users
area, click the
Delete
icon in the row in the table that corresponds to the user you want to delete.
Configuring HTTPS
This section describes how to configure HTTPS on the FXOS chassis.
Note
You can change the HTTPS port using Firepower Chassis Manager or the FXOS CLI. All other HTTPS configuration can only be done using the FXOS CLI.
Certificates, Key Rings, and Trusted Points
HTTPS uses components of the Public Key Infrastructure (PKI) to establish secure communications between two devices, such as a client's browser and the FXOS chassis.
Encryption Keys and Key Rings
Each PKI device holds a pair of asymmetric Rivest-Shamir-Adleman (RSA) encryption keys, one kept private and one made public, stored in an internal key ring. A message encrypted with either key can be decrypted
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
89
Platform Settings
Creating a Key Ring
with the other key. To send an encrypted message, the sender encrypts the message with the receiver's public key, and the receiver decrypts the message using its own private key. A sender can also prove its ownership of a public key by encrypting (also called 'signing') a known message with its own private key. If a receiver can successfully decrypt the message using the public key in question, the sender's possession of the corresponding private key is proven. Encryption keys can vary in length, with typical lengths from 512 bits to 2048 bits. In general, a longer key is more secure than a shorter key. FXOS provides a default key ring with an initial 2048-bit key pair, and allows you to create additional key rings.
The default key ring certificate must be manually regenerated if the cluster name changes or the certificate expires.
Certificates
To prepare for secure communications, two devices first exchange their digital certificates. A certificate is a file containing a device's public key along with signed information about the device's identity. To merely support encrypted communications, a device can generate its own key pair and its own self-signed certificate.
When a remote user connects to a device that presents a self-signed certificate, the user has no easy method to verify the identity of the device, and the user's browser will initially display an authentication warning. By default, FXOS contains a built-in self-signed certificate containing the public key from the default key ring.
Trusted Points
To provide stronger authentication for FXOS, you can obtain and install a third-party certificate from a trusted source, or trusted point, that affirms the identity of your device. The third-party certificate is signed by the issuing trusted point, which can be a root certificate authority (CA) or an intermediate CA or trust anchor that is part of a trust chain that leads to a root CA. To obtain a new certificate, you must generate a certificate request through FXOS and submit the request to a trusted point.
Important
The certificate must be in Base64 encoded X.509 (CER) format.
Creating a Key Ring
FXOS supports a maximum of 8 key rings, including the default key ring.
Procedure
Step 1
Enter security mode:
Firepower-chassis #
scope security
Step 2
Create and name the key ring:
Firepower-chassis # create keyring keyring-name
Step 3
Set the SSL key length in bits:
Firepower-chassis #
set modulus
{
mod1024
|
mod1536
|
mod2048
|
mod512
}
Step 4
Commit the transaction:
Firepower-chassis #
commit-buffer
90
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Regenerating the Default Key Ring
The following example creates a keyring with a key size of 1024 bits:
Firepower-chassis#
scope security
Firepower-chassis /security #
create keyring kr220
Firepower-chassis /security/keyring* #
set modulus mod1024
Firepower-chassis /security/keyring* #
commit-buffer
Firepower-chassis /security/keyring #
What to Do Next
Create a certificate request for this key ring.
Regenerating the Default Key Ring
The default key ring certificate must be manually regenerated if the cluster name changes or the certificate expires.
Procedure
Step 1
Enter security mode:
Firepower-chassis #
scope security
Step 2
Enter key ring security mode for the default key ring:
Firepower-chassis /security #
scope keyring default
Step 3
Regenerate the default key ring:
Firepower-chassis /security/keyring #
set regenerate yes
Step 4
Commit the transaction:
Firepower-chassis #
commit-buffer
The following example regenerates the default key ring:
Firepower-chassis#
scope security
Firepower-chassis /security #
scope keyring default
Firepower-chassis /security/keyring* #
set regenerate yes
Firepower-chassis /security/keyring* #
commit-buffer
Firepower-chassis /security/keyring #
Creating a Certificate Request for a Key Ring
Creating a Certificate Request for a Key Ring with Basic Options
Procedure
Step 1
Enter security mode:
Firepower-chassis #
scope security
Step 2
Enter configuration mode for the key ring:
Firepower-chassis /security # scope keyring keyring-name
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
91
Platform Settings
Creating a Certificate Request for a Key Ring
Step 3
Create a certificate request using the IPv4 or IPv6 address specified, or the name of the fabric interconnect.
You are prompted to enter a password for the certificate request.
Firepower-chassis /security/keyring #
create certreq
{
ip
[
ipv4-addr
|
ipv6-v6
] | subject-name name }
Step 4
Commit the transaction:
Firepower-chassis /security/keyring/certreq #
commit-buffer
Step 5
Display the certificate request, which you can copy and send to a trust anchor or certificate authority:
Firepower-chassis /security/keyring #
show certreq
The following example creates and displays a certificate request with an IPv4 address for a key ring, with basic options:
Firepower-chassis#
scope security
Firepower-chassis /security #
scope keyring kr220
Firepower-chassis /security/keyring #
create certreq ip 192.168.200.123 subject-name sjc04
Certificate request password:
Confirm certificate request password:
Firepower-chassis /security/keyring* #
commit-buffer
Firepower-chassis /security/keyring #
show certreq
Certificate request subject name: sjc04
Certificate request ip address: 192.168.200.123
Certificate request e-mail name:
Certificate request country name:
State, province or county (full name):
Locality (eg, city):
Organization name (eg, company):
Organization Unit name (eg, section):
Request:
-----BEGIN CERTIFICATE REQUEST-----
MIIBfTCB5wIBADARMQ8wDQYDVQQDEwZzYW1jMDQwgZ8wDQYJKoZIhvcNAQEBBQAD gY0AMIGJAoGBALpKn1t8qMZO4UGqILKFXQQc2c8b/vW2rnRF8OPhKbhghLA1YZ1F
JqcYEG5Yl1+vgohLBTd45s0GC8m4RTLJWHo4SwccAUXQ5Zngf45YtX1WsylwUWV4
0re/zgTk/WCd56RfOBvWR2Dtztu2pGA14sd761zLxt29K7R8mzj6CAUVAgMBAAGg
LTArBgkqhkiG9w0BCQ4xHjAcMBoGA1UdEQEB/wQQMA6CBnNhbWMwNIcECsEiXjAN
BgkqhkiG9w0BAQQFAAOBgQCsxN0qUHYGFoQw56RwQueLTNPnrndqUwuZHUO03Teg nhsyu4satpyiPqVV9viKZ+spvc6x5PWIcTWgHhH8BimOb/0OKuG8kwfIGGsEDlAv
TTYvUP+BZ9OFiPbRIA718S+V8ndXr1HejiQGxlDNqoN+odCXPc5kjoXD0lZTL09H
BA==
-----END CERTIFICATE REQUEST-----
Firepower-chassis /security/keyring #
What to Do Next
• Copy the text of the certificate request, including the BEGIN and END lines, and save it in a file. Send the file with the certificate request to a trust anchor or certificate authority to obtain a certificate for the key ring.
• Create a trusted point and set the certificate chain for the certificate of trust received from the trust anchor.
Creating a Certificate Request for a Key Ring with Advanced Options
Procedure
Step 1
Enter security mode:
Firepower-chassis #
scope security
92
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Creating a Certificate Request for a Key Ring
Step 2
Enter configuration mode for the key ring:
Firepower-chassis /security # scope keyring keyring-name
Step 3
Create a certificate request:
Firepower-chassis /security/keyring #
create certreq
Step 4
Specify the country code of the country in which the company resides:
Firepower-chassis /security/keyring/certreq* # set country country name
Step 5
Specify the Domain Name Server (DNS) address associated with the request:
Firepower-chassis /security/keyring/certreq* # set dns DNS Name
Step 6
Specify the email address associated with the certificate request:
Firepower-chassis /security/keyring/certreq* # set e-mail E-mail name
Step 7
Specify the IP address of the FXOS chassis:
Firepower-chassis /security/keyring/certreq* #
set ip
{
certificate request ip-address|certificate request ip6-address
}
Step 8
Specify the city or town in which the company requesting the certificate is headquartered:
Firepower-chassis /security/keyring/certreq* # set locality locality name (eg, city)
Step 9
Specify the organization requesting the certificate:
Firepower-chassis /security/keyring/certreq* # set org-name organization name
Step 10
Specify the organizational unit:
Firepower-chassis /security/keyring/certreq* #
set org-unit-name organizational unit name
Step 11
Specify an optional password for the certificate request:
Firepower-chassis /security/keyring/certreq* #
set password certificate request password
Step 12
Specify the state or province in which the company requesting the certificate is headquartered:
Firepower-chassis /security/keyring/certreq* # set state state, province or county
Step 13
Specify the fully qualified domain name of the FXOS chassis:
Firepower-chassis /security/keyring/certreq* # set subject-name certificate request name
Step 14
Commit the transaction:
Firepower-chassis /security/keyring/certreq #
commit-buffer
Step 15
Display the certificate request, which you can copy and send to a trust anchor or certificate authority:
Firepower-chassis /security/keyring #
show certreq
The following example creates and displays a certificate request with an IPv4 address for a key ring, with advanced options:
Firepower-chassis#
scope security
Firepower-chassis /security #
scope keyring kr220
Firepower-chassis /security/keyring #
create certreq
Firepower-chassis /security/keyring/certreq* #
set ip 192.168.200.123
Firepower-chassis /security/keyring/certreq* #
set subject-name sjc04
Firepower-chassis /security/keyring/certreq* #
set country US
Firepower-chassis /security/keyring/certreq* #
set dns bg1-samc-15A
Firepower-chassis /security/keyring/certreq* #
set email [email protected]
Firepower-chassis /security/keyring/certreq* #
set locality new york city
Firepower-chassis /security/keyring/certreq* #
set org-name "Cisco Systems"
Firepower-chassis /security/keyring/certreq* #
set org-unit-name Testing
Firepower-chassis /security/keyring/certreq* #
set state new york
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
93
Platform Settings
Creating a Trusted Point
Firepower-chassis /security/keyring/certreq* #
commit-buffer
Firepower-chassis /security/keyring/certreq #
show certreq
Certificate request subject name: sjc04
Certificate request ip address: 192.168.200.123
Certificate request e-mail name: [email protected]
Certificate request country name: US
State, province or county (full name): New York
Locality name (eg, city): new york city
Organization name (eg, company): Cisco
Organization Unit name (eg, section): Testing
Request:
-----BEGIN CERTIFICATE REQUEST-----
MIIBfTCB5wIBADARMQ8wDQYDVQQDEwZzYW1jMDQwgZ8wDQYJKoZIhvcNAQEBBQAD gY0AMIGJAoGBALpKn1t8qMZO4UGqILKFXQQc2c8b/vW2rnRF8OPhKbhghLA1YZ1F
JqcYEG5Yl1+vgohLBTd45s0GC8m4RTLJWHo4SwccAUXQ5Zngf45YtX1WsylwUWV4
0re/zgTk/WCd56RfOBvWR2Dtztu2pGA14sd761zLxt29K7R8mzj6CAUVAgMBAAGg
LTArBgkqhkiG9w0BCQ4xHjAcMBoGA1UdEQEB/wQQMA6CBnNhbWMwNIcECsEiXjAN
BgkqhkiG9w0BAQQFAAOBgQCsxN0qUHYGFoQw56RwQueLTNPnrndqUwuZHUO03Teg nhsyu4satpyiPqVV9viKZ+spvc6x5PWIcTWgHhH8BimOb/0OKuG8kwfIGGsEDlAv
TTYvUP+BZ9OFiPbRIA718S+V8ndXr1HejiQGxlDNqoN+odCXPc5kjoXD0lZTL09H
BA==
-----END CERTIFICATE REQUEST-----
Firepower-chassis /security/keyring/certreq #
What to Do Next
• Copy the text of the certificate request, including the BEGIN and END lines, and save it in a file. Send the file with the certificate request to a trust anchor or certificate authority to obtain a certificate for the key ring.
• Create a trusted point and set the certificate chain for the certificate of trust received from the trust anchor.
Creating a Trusted Point
Procedure
Step 1
Enter security mode:
Firepower-chassis #
scope security
Step 2
Create a trusted point:
Firepower-chassis /security #
create trustpoint name
Step 3
Specify certificate information for this trusted point:
Firepower-chassis /security/trustpoint #
set certchain
[
certchain
]
If you do not specify certificate information in the command, you are prompted to enter a certificate or a list of trustpoints defining a certification path to the root certificate authority (CA). On the next line following your input, type ENDOFBUF to finish.
Important
The certificate must be in Base64 encoded X.509 (CER) format.
Step 4
Commit the transaction:
Firepower-chassis /security/trustpoint #
commit-buffer
94
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Importing a Certificate into a Key Ring
The following example creates a trusted point and provides a certificate for the trusted point:
Firepower-chassis#
scope security
Firepower-chassis /security #
create trustpoint tPoint10
Firepower-chassis /security/trustpoint* #
set certchain
Enter lines one at a time. Enter ENDOFBUF to finish. Press ^C to abort.
Trustpoint Certificate Chain:
>
-----BEGIN CERTIFICATE-----
>
MIIDMDCCApmgAwIBAgIBADANBgkqhkiG9w0BAQQFADB0MQswCQYDVQQGEwJVUzEL
>
BxMMU2FuIEpvc2UsIENBMRUwEwYDVQQKEwxFeGFtcGxlIEluYy4xEzARBgNVBAsT
>
ClRlc3QgR3JvdXAxGTAXBgNVBAMTEHRlc3QuZXhhbXBsZS5jb20xHzAdBgkqhkiG
>
9w0BCQEWEHVzZXJAZXhhbXBsZS5jb20wgZ8wDQYJKoZIhvcNAQEBBQADgY0AMIGJ
>
AoGBAMZw4nTepNIDhVzb0j7Z2Je4xAG56zmSHRMQeOGHemdh66u2/XAoLx7YCcYU
>
ZgAMivyCsKgb/6CjQtsofvtrmC/eAehuK3/SINv7wd6Vv2pBt6ZpXgD4VBNKONDl
>
GMbkPayVlQjbG4MD2dx2+H8EH3LMtdZrgKvPxPTE+bF5wZVNAgMBAAGgJTAjBgkq
>
hkiG9w0BCQcxFhMUQSBjaGFsbGVuZ2UgcGFzc3dvcmQwDQYJKoZIhvcNAQEFBQAD
>
gYEAG61CaJoJaVMhzCl903O6Mg51zq1zXcz75+VFj2I6rH9asckCld3mkOVx5gJU
>
Ptt5CVQpNgNLdvbDPSsXretysOhqHmp9+CLv8FDuy1CDYfuaLtvlWvfhevskV0j6
>
jtcEMyZ+f7+3yh421ido3nO4MIGeBgNVHSMEgZYwgZOAFLlNjtcEMyZ+f7+3yh42
>
1ido3nO4oXikdjB0MQswCQYDVQQGEwJVUzELMAkGA1UECBMCQ0ExFDASBgNVBAcT
>
C1NhbnRhIENsYXJhMRswGQYDVQQKExJOdW92YSBTeXN0ZW1zIEluYy4xFDASBgNV
>
BAsTC0VuZ2luZWVyaW5nMQ8wDQYDVQQDEwZ0ZXN0Q0GCAQAwDAYDVR0TBAUwAwEB
>
/zANBgkqhkiG9w0BAQQFAAOBgQAhWaRwXNR6B4g6Lsnr+fptHv+WVhB5fKqGQqXc
>
wR4pYiO4z42/j9Ijenh75tCKMhW51az8copP1EBmOcyuhf5C6vasrenn1ddkkYt4
>
PR0vxGc40whuiozBolesmsmjBbedUCwQgdFDWhDIZJwK5+N3x/kfa2EHU6id1avt
>
4YL5Jg==
>
-----END CERTIFICATE-----
>
ENDOFBUF
Firepower-chassis /security/trustpoint* #
commit-buffer
Firepower-chassis /security/trustpoint #
What to Do Next
Obtain a key ring certificate from the trust anchor or certificate authority and import it into the key ring.
Importing a Certificate into a Key Ring
Before You Begin
• Configure a trusted point that contains the certificate chain for the key ring certificate.
• Obtain a key ring certificate from a trust anchor or certificate authority.
Procedure
Step 1
Enter security mode:
Firepower-chassis #
scope security
Step 2
Enter configuration mode for the key ring that will receive the certificate:
Firepower-chassis /security #
scope keyring keyring-name
Step 3
Specify the trusted point for the trust anchor or certificate authority from which the key ring certificate was obtained:
Firepower-chassis /security/keyring # set trustpoint name
Step 4
Launch a dialog for entering and uploading the key ring certificate:
Firepower-chassis /security/keyring #
set cert
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
95
Platform Settings
Configuring HTTPS
At the prompt, paste the certificate text that you received from the trust anchor or certificate authority. On the next line following the certificate, type ENDOFBUF to complete the certificate input.
Important
The certificate must be in Base64 encoded X.509 (CER) format.
Step 5
Commit the transaction:
Firepower-chassis /security/keyring #
commit-buffer
The following example specifies the trust point and imports a certificate into a key ring:
Firepower-chassis#
scope security
Firepower-chassis /security #
scope keyring kr220
Firepower-chassis /security/keyring #
set trustpoint tPoint10
Firepower-chassis /security/keyring* #
set cert
Enter lines one at a time. Enter ENDOFBUF to finish. Press ^C to abort.
Keyring certificate:
>
-----BEGIN CERTIFICATE-----
>
MIIB/zCCAWgCAQAwgZkxCzAJBgNVBAYTAlVTMQswCQYDVQQIEwJDQTEVMBMGA1UE
>
BxMMU2FuIEpvc2UsIENBMRUwEwYDVQQKEwxFeGFtcGxlIEluYy4xEzARBgNVBAsT
>
ClRlc3QgR3JvdXAxGTAXBgNVBAMTEHRlc3QuZXhhbXBsZS5jb20xHzAdBgkqhkiG
>
9w0BCQEWEHVzZXJAZXhhbXBsZS5jb20wgZ8wDQYJKoZIhvcNAQEBBQADgY0AMIGJ
>
AoGBAMZw4nTepNIDhVzb0j7Z2Je4xAG56zmSHRMQeOGHemdh66u2/XAoLx7YCcYU
>
ZgAMivyCsKgb/6CjQtsofvtrmC/eAehuK3/SINv7wd6Vv2pBt6ZpXgD4VBNKONDl
>
GMbkPayVlQjbG4MD2dx2+H8EH3LMtdZrgKvPxPTE+bF5wZVNAgMBAAGgJTAjBgkq
>
hkiG9w0BCQcxFhMUQSBjaGFsbGVuZ2UgcGFzc3dvcmQwDQYJKoZIhvcNAQEFBQAD
>
gYEAG61CaJoJaVMhzCl903O6Mg51zq1zXcz75+VFj2I6rH9asckCld3mkOVx5gJU
>
Ptt5CVQpNgNLdvbDPSsXretysOhqHmp9+CLv8FDuy1CDYfuaLtvlWvfhevskV0j6
>
mK3Ku+YiORnv6DhxrOoqau8r/hyI/L43l7IPN1HhOi3oha4=
>
-----END CERTIFICATE-----
>
ENDOFBUF
Firepower-chassis /security/keyring* #
commit-buffer
Firepower-chassis /security/keyring #
What to Do Next
Configure your HTTPS service with the key ring.
Configuring HTTPS
Caution
After you complete the HTTPS configuration, including changing the port and key ring to be used by
HTTPS, all current HTTP and HTTPS sessions are closed without warning as soon as you save or commit the transaction.
Procedure
Step 1
Enter system mode:
Firepower-chassis#
scope system
Step 2
Enter system services mode:
Firepower-chassis /system #
scope services
Step 3
Enable the HTTPS service:
Firepower-chassis /system/services #
enable https
96
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Changing the HTTPS Port
Step 4
(Optional) Specify the port to be used for the HTTPS connection:
Firepower-chassis /system/services # set https port port-num
Step 5
(Optional) Specify the name of the key ring you created for HTTPS:
Firepower-chassis /system/services #
set https keyring keyring-name
Step 6
(Optional) Specify the level of Cipher Suite security used by the domain:
Firepower-chassis /system/services # set https cipher-suite-mode cipher-suite-mode
cipher-suite-mode
can be one of the following keywords:
•
high-strength
•
medium-strength
•
low-strength
•
custom
—
Allows you to specify a user-defined Cipher Suite specification string.
Step 7
(Optional) If
cipher-suite-mode
is set to
custom
, specify a custom level of Cipher Suite security for the domain:
Firepower-chassis /system/services # set https cipher-suite cipher-suite-spec-string
cipher-suite-spec-string
can contain up to 256 characters and must conform to the OpenSSL Cipher Suite specifications. You cannot use any spaces or special characters except ! (exclamation point), + (plus sign), -
(hyphen), and : (colon). For details, see http://httpd.apache.org/docs/2.0/mod/mod_ssl.html#sslciphersuite .
For example, the medium strength specification string FXOS uses as the default is:
ALL:!ADH:!EXPORT56:!LOW:RC4+RSA:+HIGH:+MEDIUM:+EXP:+eNULL
Note
This option is ignored if
cipher-suite-mode
is set to anything other than
custom
.
Step 8
Commit the transaction to the system configuration:
Firepower-chassis /system/services #
commit-buffer
The following example enables HTTPS, sets the port number to 443, sets the key ring name to kring7984, sets the Cipher Suite security level to high, and commits the transaction:
Firepower-chassis#
scope system
Firepower-chassis /system #
scope services
Firepower-chassis /system/services #
enable https
Firepower-chassis /system/services* #
set https port 443
Warning: When committed, this closes all the web sessions.
Firepower-chassis /system/services* #
set https keyring kring7984
Firepower-chassis /system/services* #
set https cipher-suite-mode high
Firepower-chassis /system/services* #
commit-buffer
Firepower-chassis /system/services #
Changing the HTTPS Port
The HTTPS service is enabled on port 443 by default. You cannot disable HTTPS, but you can change the port to use for HTTPS connections.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
97
Platform Settings
Deleting a Key Ring
Procedure
Step 1
Choose
Platform Settings
>
HTTPS
.
Step 2
Enter the port to use for HTTPS connections in the
Port
field. Specify an integer between 1 and 65535. This service is enabled on port 443 by default.
Step 3
Click
Save
.
The Firepower chassis is configured with the HTTPS port specified.
After changing the HTTPS port, all current HTTPS sessions are closed. Users will need to log back in to the
Firepower Chassis Manager using the new port as follows: https://
<chassis_mgmt_ip_address>
:
<chassis_mgmt_port>
where
<chassis_mgmt_ip_address>
is the IP address or host name of the Firepower chassis that you entered during initial configuration and
<chassis_mgmt_port>
is the HTTPS port you have just configured.
Deleting a Key Ring
Procedure
Step 1
Enter security mode:
Firepower-chassis #
scope security
Step 2
Delete the named key ring:
Firepower-chassis /security #
delete keyring name
Step 3
Commits the transaction:
Firepower-chassis /security #
commit-buffer
The following example deletes a key ring:
Firepower-chassis#
scope security
Firepower-chassis /security #
delete keyring key10
Firepower-chassis /security* #
commit-buffer
Firepower-chassis /security #
Deleting a Trusted Point
Before You Begin
Ensure that the trusted point is not used by a key ring.
Procedure
Step 1
Enters security mode:
98
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Disabling HTTPS
Firepower-chassis#
scope security
Step 2
Delete the named trusted point:
Firepower-chassis /security #
delete trustpoint name
Step 3
Commits the transaction:
Firepower-chassis /security #
commit-buffer
The following example deletes a trusted point:
Firepower-chassis#
scope security
Firepower-chassis /security #
delete trustpoint tPoint10
Firepower-chassis /security* #
commit-buffer
Firepower-chassis /security #
Disabling HTTPS
Procedure
Step 1
Enter system mode:
Firepower-chassis#
scope system
Step 2
Enter system services mode:
Firepower-chassis /system #
scope services
Step 3
Disable the HTTPS service:
Firepower-chassis /system/services #
disable https
Step 4
Commit the transaction to the system configuration:
Firepower-chassis /system/services #
commit-buffer
The following example disables HTTPS and commits the transaction:
Firepower-chassis#
scope system
Firepower-chassis /system #
scope services
Firepower-chassis /system/services #
disable https
Firepower-chassis /system/services* #
commit-buffer
Firepower-chassis /system/services #
Configuring AAA
This section describes authentication, authorization, and accounting. See the following topics for more information:
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
99
Platform Settings
About AAA
About AAA
AAA is a set of services for controlling access to computer resources, enforcing policies, assessing usage, and providing the information necessary to bill for services. These processes are considered important for effective network management and security.
Authentication
Authentication provides a way to identify a user, typically by having the user enter a valid username and valid password before access is granted. The AAA server compares a user's authentication credentials with other user credentials stored in a database. If the credentials match, the user is permitted access to the network. If the credentials do not match, authentication fails and network access is denied.
You can configure the FXOS chassis to authenticate administrative connections to the chassis, including the following sessions:
• HTTPS
• SSH
• Serial console
Authorization
Authorization is the process of enforcing policies: determining what types of activities, resources, or services a user is permitted to access. After a user is authenticated, that user may be authorized for different types of access or activity.
Accounting
Accounting measures the resources a user consumes during access, which may include the amount of system time or the amount of data that a user has sent or received during a session. Accounting is carried out through the logging of session statistics and usage information, which is used for authorization control, billing, trend analysis, resource utilization, and capacity planning activities.
Interaction Between Authentication, Authorization, and Accounting
You can use authentication alone or with authorization and accounting. Authorization always requires a user to be authenticated first. You can use accounting alone, or with authentication and authorization.
AAA Servers
The AAA server is a network server that is used for access control. Authentication identifies the user.
Authorization implements policies that determine which resources and services an authenticated user may access. Accounting keeps track of time and data resources that are used for billing and analysis.
Local Database Support
The Firepower chassis maintains a local database that you can populate with user profiles. You can use a local database instead of AAA servers to provide user authentication, authorization, and accounting.
100
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Configuring LDAP Providers
Configuring LDAP Providers
Configuring Properties for LDAP Providers
The properties that you configure in this task are the default settings for all provider connections of this type.
If an individual provider includes a setting for any of these properties, the Firepower eXtensible Operating
System uses that setting and ignores the default setting.
If you are using Active Directory as your LDAP server, create a user account in the Active Directory server to bind with the Firepower eXtensible Operating System. This account should be given a non-expiring password.
Procedure
Step 1
Choose
Platform Settings
>
AAA
.
Step 2
Click the
LDAP
tab.
Step 3
In the
Properties
area, complete the following fields:
Name Description
Timeout
field The length of time in seconds the system should spend trying to contact the LDAP database before it times out.
Enter an integer from 1 to 60 seconds. The default value is 30 seconds.
This property is required.
Attribute
field
Base DN
Filter
field field
An LDAP attribute that stores the values for the user roles and locales.
This property is always a name-value pair. The system queries the user record for the value that matches this attribute name.
The specific distinguished name in the LDAP hierarchy where the server should begin a search when a remote user logs in and the system attempts to get the user's DN based on their username. The length of the base
DN can be set to a maximum of 255 characters minus the length of
CN=$userid, where $userid identifies the remote user attempting to access the Firepower chassis using LDAP authentication.
This property is required. If you do not specify a base DN on this tab then you must specify one for each LDAP provider that you define.
The LDAP search is restricted to those user names that match the defined filter.
This property is required. If you do not specify a filter on this tab then you must specify one for each LDAP provider that you define.
Step 4
Click
Save
.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
101
Platform Settings
Configuring LDAP Providers
What to Do Next
Create an LDAP provider.
Creating an LDAP Provider
The Firepower eXtensible Operating System supports a maximum of 16 LDAP providers.
Before You Begin
If you are using Active Directory as your LDAP server, create a user account in the Active Directory server to bind with the Firepower eXtensible Operating System. This account should be given a non-expiring password.
Procedure
Step 1
Choose
Platform Settings
>
AAA
.
Step 2
Click the
LDAP
tab.
Step 3
For each LDAP provider that you want to add: a) In the
LDAP Providers
area, click
Add
.
b) In the
Add LDAP Provider
dialog box, complete the following fields:
Name Description
Hostname/FDQN (or IP
Address)
field
The hostname or IP address on which the LDAP provider resides. If
SSL is enabled, this field must exactly match a Common Name (CN) in the security certificate of the LDAP database.
Order
field
Bind DN
field
The order in which the Firepower eXtensible Operating System uses this provider to authenticate users.
Enter an integer between 1 and 16, or enter lowest-available or 0
(zero) if you want the Firepower eXtensible Operating System to assign the next available order based on the other providers defined in Firepower Chassis Manager or the FXOS CLI.
The distinguished name (DN) for an LDAP database account that has read and search permissions for all objects under the base DN.
The maximum supported string length is 255 ASCII characters.
Base DN
field The specific distinguished name in the LDAP hierarchy where the server should begin a search when a remote user logs in and the system attempts to get the user's DN based on their username. The length of the base DN can be set to a maximum of 255 characters minus the length of CN=$userid, where $userid identifies the remote user attempting to access Firepower Chassis Manager or the FXOS
CLI using LDAP authentication.
This value is required unless a default base DN has been set on the
LDAP
tab.
102
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Configuring LDAP Providers
Name
Port
field
Enable SSL
check box
Filter
Attribute
Key
field field
Confirm Key
field
Timeout
field
Vendor
field field
Description
The port through which Firepower Chassis Manager or the FXOS
CLI communicates with the LDAP database. The standard port number is 389.
If checked, encryption is required for communications with the LDAP database. If unchecked, authentication information will be sent as clear text.
LDAP uses STARTTLS. This allows encrypted communication using port 389.
The LDAP search is restricted to those user names that match the defined filter.
This value is required unless a default filter has been set on the
LDAP
tab.
An LDAP attribute that stores the values for the user roles and locales.
This property is always a name-value pair. The system queries the user record for the value that matches this attribute name.
This value is required unless a default attribute has been set on the
LDAP
tab.
The password for the LDAP database account specified in the
Bind
DN
field. You can enter any standard ASCII characters except for space, § (section sign), ? (question mark), or = (equal sign).
The LDAP database password repeated for confirmation purposes.
The length of time in seconds the system should spend trying to contact the LDAP database before it times out.
Enter an integer from 1 to 60 seconds, or enter 0 (zero) to use the global timeout value specified on the
LDAP
tab. The default is 30 seconds.
This selection identifies the vendor that is providing the LDAP provider or server details:
• If the LDAP provider is Microsoft Active Directory, select
MS
AD
.
• If the LDAP provider is not Microsoft Active Directory, select
Open LDAP
.
The default is
Open LDAP
.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
103
Platform Settings
Configuring RADIUS Providers
c) Click
OK
to close the
Add LDAP Provider
dialog box.
Step 4
Click
Save
.
Step 5
(Optional) Enable the certification revocation list check:
Firepower-chassis /security/ldap/server # set revoke-policy {strict | relaxed}
Note
This configuration only takes effect if the SSL connection is enabled.
Deleting an LDAP Provider
Procedure
Step 1
Choose
Platform Settings
>
AAA
.
Step 2
Click the
LDAP
tab.
Step 3
In the
LDAP Providers
area, click the
Delete
icon in the row in the table that corresponds to the LDAP
Provider you want to delete.
Configuring RADIUS Providers
Configuring Properties for RADIUS Providers
The properties that you configure in this task are the default settings for all provider connections of this type.
If an individual provider includes a setting for any of these properties, the Firepower eXtensible Operating
System uses that setting and ignores the default setting.
Procedure
Step 1
Choose
Platform Settings
>
AAA
.
Step 2
Click the
RADIUS
tab.
Step 3
In the
Properties
area, complete the following fields:
Name Description
Timeout
field The length of time in seconds the system should spend trying to contact the RADIUS database before it times out.
Enter an integer from 1 to 60 seconds. The default value is 5 seconds.
This property is required.
Retries
field The number of times to retry the connection before the request is considered to have failed.
104
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Configuring RADIUS Providers
Step 4
Click
Save
.
What to Do Next
Create a RADIUS provider.
Creating a RADIUS Provider
The Firepower eXtensible Operating System supports a maximum of 16 RADIUS providers.
Procedure
Step 1
Choose
Platform Settings
>
AAA
.
Step 2
Click the
RADIUS
tab.
Step 3
For each RADIUS provider that you want to add: a) In the
RADIUS Providers
area, click
Add
.
b) In the
Add RADIUS Provider
dialog box, complete the following fields:
Name Description
Hostname/FDQN (or IP
Address)
field
The hostname or IP address on which the RADIUS provider resides.
Order
field
Key
field
The order in which the Firepower eXtensible Operating System uses this provider to authenticate users.
Enter an integer between 1 and 16, or enter lowest-available or 0
(zero) if you want the Firepower eXtensible Operating System to assign the next available order based on the other providers defined in Firepower Chassis Manager or the FXOS CLI.
The SSL encryption key for the database.
Confirm Key
field
Authorization Port
field
Timeout
field
The SSL encryption key repeated for confirmation purposes.
The port through which Firepower Chassis Manager or the FXOS
CLI communicates with the RADIUS database. The valid range is 1 to 65535. The standard port number is 1700.
The length of time in seconds the system should spend trying to contact the RADIUS database before it times out.
Enter an integer from 1 to 60 seconds, or enter 0 (zero) to use the global timeout value specified on the
RADIUS
tab. The default is 5 seconds.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
105
Platform Settings
Configuring TACACS+ Providers
Name
Retries
field
Description
The number of times to retry the connection before the request is considered to have failed.
If desired, enter an integer between 0 and 5. If you do not specify a value, Firepower Chassis Manager uses the value specified on the
RADIUS
tab.
c) Click
OK
to close the
Add RADIUS Provider
dialog box.
Step 4
Click
Save
.
Deleting a RADIUS Provider
Procedure
Step 1
Choose
Platform Settings
>
AAA
.
Step 2
Click the
RADIUS
tab.
Step 3
In the
RADIUS Providers
area, click the
Delete
icon in the row in the table that corresponds to the RADIUS
Provider you want to delete.
Configuring TACACS+ Providers
Configuring Properties for TACACS+ Providers
The properties that you configure in this task are the default settings for all provider connections of this type.
If an individual provider includes a setting for any of these properties, the Firepower eXtensible Operating
System uses that setting and ignores the default setting.
Procedure
Step 1
Choose
Platform Settings
>
AAA
.
Step 2
Click the
TACACS
tab.
Step 3
In the
Properties
area, complete the following fields:
106
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Configuring TACACS+ Providers
Name
Timeout
field
Description
The length of time in seconds the system should spend trying to contact the TACACS+ database before it times out.
Enter an integer from 1 to 60 seconds. The default value is 5 seconds.
This property is required.
Step 4
Click
Save
.
What to Do Next
Create a TACACS+ provider.
Creating a TACACS+ Provider
The Firepower eXtensible Operating System supports a maximum of 16 TACACS+ providers.
Procedure
Step 1
Choose
Platform Settings
>
AAA
.
Step 2
Click the
TACACS
tab.
Step 3
For each TACACS+ provider that you want to add: a) In the
TACACS Providers
area, click
Add
.
b) In the
Add TACACS Provider
dialog box, complete the following fields:
Name Description
Hostname/FDQN (or IP
Address)
field
The hostname or IP address on which the TACACS+ provider resides.
Order
field The order in which the Firepower eXtensible Operating System uses this provider to authenticate users.
Enter an integer between 1 and 16, or enter lowest-available or 0
(zero) if you want the Firepower eXtensible Operating System to assign the next available order based on the other providers defined in Firepower Chassis Manager or the FXOS CLI.
Key
Port
field
Confirm Key
field field
The SSL encryption key for the database.
The SSL encryption key repeated for confirmation purposes.
The port through which Firepower Chassis Manager or the FXOS
CLI communicates with the TACACS+ database.
Enter an integer between 1 and 65535. The default port is 49.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
107
Platform Settings
Configuring Syslog
Name
Timeout
field
Description
The length of time in seconds the system should spend trying to contact the TACACS+ database before it times out.
Enter an integer from 1 to 60 seconds, or enter 0 (zero) to use the global timeout value specified on the
TACACS+
tab. The default is
5 seconds.
c) Click
OK
to close the
Add TACACS Provider
dialog box.
Step 4
Click
Save
.
Deleting a TACACS+ Provider
Procedure
Step 1
Choose
Platform Settings
>
AAA
.
Step 2
Click the
TACACS
tab.
Step 3
In the
TACACS Providers
area, click the
Delete
icon in the row in the table that corresponds to the TACACS+
Provider you want to delete.
Configuring Syslog
System logging is a method of collecting messages from devices to a server running a syslog daemon. Logging to a central syslog server helps in aggregation of logs and alerts. A syslog service accepts messages and stores them in files, or prints them according to a simple configuration file. This form of logging provides protected long-term storage for logs. Logs are useful both in routine troubleshooting and in incident handling.
Procedure
Step 1
Choose
Platform Settings
>
Syslog
.
Step 2
Configure Local Destinations: a) Click the
Local Destinations
tab.
b) On the
Local Destinations
tab, complete the following fields:
Name Description
Console
Section
108
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Configuring Syslog
Name
Admin State
Level
field
Monitor
field
Section
Admin State
field
Level
drop-down list
Description
Whether the Firepower chassis displays syslog messages on the console.
Check the
Enable
check box if you want to have syslog messages displayed on the console as well as added to the log. If the
Enable
check box is unchecked, syslog messages are added to the log but are not displayed on the console.
If you checked the
Enable
check box for
Console - Admin State
, select the lowest message level that you want displayed on the console.
The Firepower chassis displays that level and above on the console.
This can be one of the following:
•
Emergencies
•
Alerts
•
Critical
Whether the Firepower chassis displays syslog messages on the monitor.
Check the
Enable
check box if you want to have syslog messages displayed on the monitor as well as added to the log. If the
Enable
check box is unchecked, syslog messages are added to the log but are not displayed on the monitor.
If you checked the
Enable
check box for
Monitor - Admin State
, select the lowest message level that you want displayed on the monitor. The system displays that level and above on the monitor.
This can be one of the following:
•
Emergencies
•
Alerts
•
Critical
•
Errors
•
Warnings
•
Notifications
•
Information
•
Debugging
c) Click
Save
.
Step 3
Configure Remote Destinations:
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
109
Platform Settings
Configuring Syslog
a) Click the
Remote Destinations
tab.
b) On the
Remote Destinations
tab, complete the following fields for up to three external logs that can store messages generated by the Firepower chassis:
By sending syslog messages to a remote destination, you can archive messages according to the available disk space on the external syslog server, and manipulate logging data after it is saved. For example, you could specify actions to be executed when certain types of syslog messages are logged, extract data from the log and save the records to another file for reporting, or track statistics using a site-specific script.
Name
Admin State
field
Description
Check the
Enable
check box if you want to have syslog messages stored in a remote log file.
Level
drop-down list Select the lowest message level that you want the system to store.
The system stores that level and above in the remote file. This can be one of the following:
•
Emergencies
•
Alerts
•
Critical
•
Errors
•
Warnings
•
Notifications
•
Information
•
Debugging
Hostname/IP Address
field
Facility
drop-down list
The hostname or IP address on which the remote log file resides.
Note
You must configure a DNS server if you use a hostname rather than an IP address.
Choose a system log facility for syslog servers to use as a basis to file messages. This can be one of the following:
•
Local0
•
Local1
•
Local2
•
Local3
•
Local4
•
Local5
•
Local6
•
Local7
110
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Platform Settings
Configuring DNS Servers
c) Click
Save
.
Step 4
Configure Local Sources: a) Click the
Local Sources
tab.
b) On the
Local Sources
tab, complete the following fields:
Name Description
Faults Admin State
field Whether system fault logging is enabled or not. If the
Enable
check box is checked, the Firepower chassis logs all system faults.
Audits Admin State
field
Events Admin State
field
Whether audit logging is enabled or not. If the
Enable
check box is checked, the Firepower chassis logs all audit log events.
Whether system event logging is enabled or not. If the
Enable
check box is checked, the Firepower chassis logs all system events.
c) Click
Save
.
Configuring DNS Servers
You need to specify a DNS server if the system requires resolution of host names to IP addresses. For example, you cannot use a name such as www.cisco.com when you are configuring a setting on the Firepower chassis if you do not configure a DNS server. You would need to use the IP address of the server, which can be either an IPv4 or an IPv6 address. You can configure up to four DNS servers.
Note
When you configure multiple DNS servers, the system searches for the servers only in any random order.
If a local management command requires DNS server lookup, it can only search for three DNS servers in random order.
Procedure
Step 1
Choose
Platform Settings
>
DNS
.
Step 2
Check the
Enable DNS Server
check box.
Step 3
For each DNS server that you want to add, up to a maximum of four, enter the IP address of the DNS server in the
DNS Server
field and click
Add
.
Step 4
Click
Save
.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
111
Configuring DNS Servers
Platform Settings
112
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
9
Interface Management
•
About Firepower Security Appliance Interfaces, page 113
•
Edit Interface Properties, page 116
•
Change the Administrative State of an Interface, page 116
•
Create a Port Channel, page 117
•
Configuring Breakout Cables, page 118
About Firepower Security Appliance Interfaces
The FXOS chassis supports single interfaces as well as EtherChannel (port-channel) Interfaces. EtherChannel interfaces can include up to 16 member interfaces of the same type.
Interfaces Page
From the Interfaces page of the Firepower Chassis Manager, you can view the status of the installed interfaces on the chassis, edit interface properties, enable or disable an interface, and create port channels.
The Interfaces page is made up of two sections:
• The upper section shows a visual representation of the interfaces that are installed in the Firepower chassis. You can hover over any of the interfaces to get additional information about the interface.
The interfaces are color coded to indicate their current status:
◦ Green — The interface is installed and enabled.
◦ Dark Grey — The interface is installed but disabled.
◦
Red
—
There is a problem with the operational state of the interface.
◦
Light Grey
—
The interface is not installed.
• The lower section contains two tabs:
All Interfaces
and
Hardware Bypass
. On the
All Interfaces
tab:
For each interface, you can enable or disable the interface. You can also click
Edit
to edit the properties
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
113
Interface Management
Interface Types
of an interface, such as speed and interface type. For
Hardware Bypass
, see
on page 115 .
Note
The port-channel 48 cluster type interface shows the
Operation State
as
failed
if it does not include any member interfaces. For intra-chassis clustering, this EtherChannel does not require any member interfaces, and you can ignore this Operational State.
Interface Types
Each interface can be one of the following types:
• Data (the default)--Data interfaces cannot be shared between logical devices.
• Management--Management interfaces can be shared between logical devices. You can only assign one management interface per logical device.
Within the Firepower Threat Defense application, the physical management interface is shared between the Diagnostic logical interface and the Management logical interface. The Management logical interface is separate from the other interfaces on the device. It is used to set up and register the device to the
Firepower Management Center. It runs a separate SSH server and uses its own local authentication, IP address, and static routing. You can configure its settings at the CLI using the
configure network
command, and also change the IP address from the Management Center
Devices
>
Device Management
>
Devices
>
Management
area.
The Diagnostic logical interface can be configured along with the rest of the data interfaces on the
Management Center
Devices
>
Device Management
>
Interfaces
screen. Using the Diagnostic interface is optional. The Diagnostic interface and data interfaces allow for LDAP or RADIUS external authentication. If you do not want to allow SSH access on a data interface, for example, then you may choose to configure the Diagnostic interface for SSH access. The Diagnostic interface only allows management traffic, and does not allow through traffic.
• Firepower-eventing--This interface is a secondary management interface for Firepower Threat Defense devices. To use this interface, you must configure its IP address and other parameters at the Firepower
Threat Defense CLI. For example, you can separate management traffic from events (such as web events).
See the
configure network
commands in the Firepower Management Center command reference.
• Cluster--Special interface type used for a clustered logical device. This type is automatically assigned to the cluster control link for inter-unit cluster communications. By default, the cluster control link is automatically created on Port-channel 48.
114
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Interface Management
Hardware Bypass Pairs
Note
You can use the Firepower Management Center or Firepower Threat Defense CLI to configure two uplink or breakout port interfaces into an inline pair. Once two ports are configured in an inline pair, they act as one single interface. This configuration is then propagated to the FXOS chassis.
Note the following restrictions for inline pairs:
• The two port interfaces must be unique. Once joining one inline pair, the ports cannot join another inline pair.
• Only data uplink ports or breakout ports can be configured into inline pairs.
For more information, see the Configure an Inline Set of IPS-Only Interfaces topic in the Firepower
Management Center Configuration Guide.
Hardware Bypass Pairs
For the Firepower Threat Defense, certain interface modules on the Firepower 9300 and 4100 series let you enable the Hardware Bypass feature. Hardware Bypass ensures that traffic continues to flow between an inline interface pair during a power outage. This feature can be used to maintain network connectivity in the case of software or hardware failures.
The Hardware Bypass feature is configured within the Hardware Bypass application. You do not need to use these interfaces as Hardware Bypass pairs; they can be used as regular interfaces for both the ASA and the
Firepower Threat Defense applications. Note that Hardware Bypass-capable interfaces cannot be configured for breakout ports. If you want to use the Hardware Bypass feature, do not configure the ports as EtherChannels; otherwise, you can include these interfaces as EtherChannel members in regular interface mode.
The Firepower Threat Defense supports Hardware Bypass for interface pairs on specific network modules on the following models:
• Firepower 9300
• Firepower 4100 series
The supported Hardware Bypass network modules for these models include:
• Firepower 6-port 1G SX FTW Network Module single-wide (FPR-NM-6X1SX-F)
• Firepower 6-port 10G SR FTW Network Module single-wide (FPR-NM-6X10SR-F)
• Firepower 6-port 10G LR FTW Network Module single-wide (FPR-NM-6X10LR-F)
• Firepower 2-port 40G SR FTW Network Module single-wide (FPR-NM-2X40G-F)
Hardware Bypass can only use the following port pairs:
• 1 & 2
• 3 & 4
• 5 & 6
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
115
Interface Management
Jumbo Frame Support
Jumbo Frame Support
The FXOS chassis has support for jumbo frames enabled by default. To enable jumbo frame support on a specific logical device installed on the FXOS chassis, you will need to configure the appropriate MTU settings for the interfaces on the logical device.
The maximum MTU that is supported for the application on the FXOS chassis is 9184.
Edit Interface Properties
Procedure
Step 1
Choose
Interfaces
to open the Interfaces page.
The Interfaces page shows a visual representation of the currently installed interfaces at the top of the page and provides a listing of the installed interfaces in the table below.
Step 2
Click
Edit
in the row for the interface you want to edit to open the
Edit Interface
dialog box.
Step 3
To enable the interface, check the
Enable
check box. To disable the interface, uncheck the
Enable
check box.
Step 4
(Optional) From the
Type
drop-down list, choose
data
to configure this interface as a data interface, choose
firepower-eventing
to configure the interface as a Firepower-eventing interface, or choose
mgmt
to configure the interface as a management interface.
Note
Do not choose the
Cluster
type.
Step 5
(Optional) Select the speed of the interface from the
Speed
drop-down list.
Step 6
Click
OK
.
Change the Administrative State of an Interface
Procedure
Step 1
Choose
Interfaces
to open the Interfaces page.
The Interfaces page shows a visual representation of the currently installed interfaces at the top of the page and provides a listing of the installed interfaces in the table below.
Step 2
For each interface whose administrative state you want to change, do one of the following:
• To set the administrative state of the interface to enabled, click the
Disabled
switch in the State column for the interface you want to enable to change the setting to
Enabled
. Click
Yes
to confirm the change.
The administrative state of the interface is changed to enabled. The corresponding interface in the visual representation changes from gray to green.
116
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Interface Management
Create a Port Channel
• To set the administrative state of the interface to disabled, click the
Enabled
switch in the State column for the interface you want to disable to change the setting to
Disabled
. Click
Yes
to confirm the change.
The administrative state of the interface is changed to disabled. The corresponding interface in the visual representation changes from green to gray.
Create a Port Channel
An EtherChannel (also known as a port-channel) can include up to 16 member interfaces of the same type.
When the FXOS chassis creates an EtherChannel, the EtherChannel stays in a
Suspended
state until you assign it to a logical device, even if the physical link is up. The EtherChannel will be brought out of this
Suspended
state in the following situations:
• The EtherChannel is added as a data or management port for a standalone logical device
• The EtherChannell is added as a management or CCL port for a logical device that is part of a cluster
• The EtherChannell is added as a data port for a logical device that is part of a cluster and at least one security module has joined the cluster
Note that the EtherChannel does not come up until you assign it to a logical device. If the EtherChannel is removed from the logical device or the logical device is deleted, the EtherChannel will revert to a
Suspended
state.
Before You Begin
The FXOS chassis only supports EtherChannels in Active Link Aggregation Control Protocol (LACP) mode.
We suggest setting the connecting switch ports to Active mode for the best compatibility.
Procedure
Step 1
Choose
Interfaces
to open the Interfaces page.
The Interfaces page shows a visual representation of the currently installed interfaces at the top of the page and provides a listing of the installed interfaces in the table below.
Step 2
Click
Add Port Channel
above the interfaces table to open the
Add Port Channel
dialog box.
Step 3
Enter an ID for the port channel in the
Port Channel ID
field. Valid values are between 1 and 47.
Port-channel 48 is reserved for the cluster control link when you deploy a clustered logical device. If you do not want to use Port-channel 48 for the cluster control link, you can configure an EtherChannel with a different
ID and choose the Cluster type for the interface. Do not assign any interfaces to the Cluster EtherChannel.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
117
Interface Management
Configuring Breakout Cables
Step 4
To enable the port channel, check the
Enable
check box. To disable the port channel, uncheck the
Enable
check box.
Step 5
Select the type of port channel from the
Type
drop-down list:
Data
,
Mgmt
, or
Cluster
.
Step 6
If not selected, click the
Interfaces
tab.
Step 7
To add an interface to the port channel, select the interface in the
Available Interface
list and click
Add
Interface
to move the interface to the Member ID list. You can add up to 16 interfaces of the same type and speed.
Tip
You can add multiple interfaces at one time. To select multiple individual interfaces, click on the desired interfaces while holding down the
Ctrl
key. To select a range of interfaces, select the first interface in the range, and then, while holding down the
Shift
key, click to select the last interface in the range.
Step 8
To remove an interface from the port channel, click the
Delete
button to the right of the interface in the Member
ID list.
Step 9
Click the
Settings
tab.
Step 10
Select the speed of the port channel from the
Speed
drop-down list.
Step 11
Click
OK
.
Configuring Breakout Cables
The following procedure shows how to configure breakout cables for use with the FXOS chassis. You can use a breakout cable to provide four 10 Gbps ports in place of a single 40 Gbps port.
Before You Begin
Hardware Bypass-capable interfaces cannot be configured for breakout ports.
Procedure
Step 1
Choose
Interfaces
to open the Interfaces page.
The Interfaces page shows a visual representation of the currently installed interfaces at the top of the page and provides a listing of the installed interfaces in the table below.
The interfaces that are capable of supporting breakout cables but are not currently configured as such are indicated by a Breakout Port icon in the row for that interface. For interfaces that have already been configured as using a breakout cable, the individual breakout interfaces are listed separately (for example, Ethernet 2/1/1,
2/1/2, 2/1/3, and 2/1/4).
Step 2
To convert a 40 Gbps interface into four 10 Gbps interfaces: a) Click the
Breakout Port
icon for the interface that you want to convert.
The Breakout Port Creation dialog box opens asking you to confirm that you want to proceed and warning you that the chassis will be rebooted.
b) Click
Yes
to confirm.
The Firepower chassis reboots and the specified interface is converted into four 10 Gbps interfaces.
Step 3
To convert the four 10 Gbps breakout interfaces back into a single 40 Gbps interface: a) Click
Delete
for any of the breakout interfaces.
118
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Interface Management
Configuring Breakout Cables
A confirmation dialog box opens asking you to confirm that you want to proceed and warning you that all four breakout interfaces will be deleted and that the chassis will be rebooted.
b) Click
Yes
to confirm.
The Firepower chassis reboots and the specified interfaces are converted into a single 40 Gbps interface.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
119
Configuring Breakout Cables
Interface Management
120
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
10
Logical Devices
•
About Logical Devices, page 121
•
Create a Standalone Logical Device, page 123
•
•
Configure Service Chaining, page 143
•
Manage Logical Devices, page 147
About Logical Devices
When you create a logical device, the FXOS chassis supervisor deploys the logical device by downloading the specified software version and pushing the bootstrap configuration and management interface settings to the specified security module/engine, or in the case of an intra-chassis cluster, to all security modules installed in the Firepower chassis.
You can create either of the following two types of logical devices:
•
Standalone
—
You can create a standalone logical device for each security module/engine installed in the Firepower chassis.
• Cluster — Clustering lets you group multiple security modules together as a single logical device. A cluster provides all the convenience of a single device (management, integration into a network) while achieving the increased throughput and redundancy of multiple devices. Multiple module devices, like the Firepower 9300, support intra-chassis clustering.
Note
On an FXOS chassis that supports multiple security modules, you can only create one type of logical device, standalone or cluster. In other words, if you have three security modules installed, you cannot create a standalone logical device on one security module and then create a cluster using the remaining two logical devices.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
121
Logical Devices
Logical Devices Page
Note
If you are configuring standalone logical devices, you must install the same software type on all modules in the chassis; different software types are not supported at this time. Note that modules can run different versions of a particular device type, but all modules must be configured as the same type of logical device.
Logical Devices Page
Use the Logical Devices page of the Firepower Chassis Manager to create, edit, and delete logical devices.
The Logical Devices page includes an informational area for the logical device(s) installed on each FXOS chassis security module/engine.
The header for each logical device area provides the following information:
• The unique name of the logical device.
• The name of the main application installed on the security module/engine, either ASA or FTD.
• The logical device mode, either Standalone or Clustered.
•
Status
—
Shows the state of the logical device:
◦ ok
—
The logical device configuration is complete.
◦ incomplete-configuration
—
The logical device configuration is incomplete.
Each logical device area provides the following information:
• Security Module — Shows the security module.
•
Ports
—
Shows the ports assigned to the application instance.
•
Application
—
Shows the application running on the security module.
• Version — Shows the software version number of the application running on the security module.
Note
Updates to Firepower Threat Defense logical devices are done using Firepower
Management Center and are not reflected on the
Logical Devices
>
Edit
and
System
>
Updates
pages in Firepower Chassis Manager. On these pages, the version shown indicates the software version (CSP image) that was used to create the Firepower Threat
Defense logical device.
•
Management IP
—
Shows the local IP address assigned as the logical device Management IP.
• Management URL — Shows the management URL assigned to the application instance.
• Gateway — Shows the network gateway address assigned to the application instance.
•
Management Port
—
Shows the management port assigned to the application instance.
•
Status
—
Shows the state of the application instance:
◦
Online
—
The application is running and operating.
122
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Create a Standalone Logical Device
◦ Offline — The application is stopped and inoperable.
◦
Installing
—
The application installation is in progress.
◦
Not Installed
—
The application is not installed.
◦ Install Failed — The application installation failed.
◦ Starting — The application is starting up.
◦
Start Failed
—
The application failed to start up.
◦
Started
—
The application started successfully, and is waiting for app agent heartbeat.
◦ Stopping — The application is in the process of stopping.
◦ Stop Failed — The application was unable to be brought offline.
◦
Not Responding
—
The application is unresponsive.
◦
Updating
—
The application software upgrade is in progress.
◦ Update Failed — The application software upgrade failed.
◦ Update Succeeded — The application software upgrade succeeded.
Create a Standalone Logical Device
You can create a standalone logical device for each security module/engine installed in the Firepower chassis.
Create a Standalone ASA Logical Device
You can create a standalone logical device for each security module/engine installed in the FXOS chassis.
On multiple module devices, like the Firepower 9300, you cannot create standalone logical devices if you have a cluster configured. You will need to delete the cluster before you can configure a standalone device.
Note
Optionally, you can install the third-party Radware DefensePro virtual platform as a DDoS detection and mitigation service that sits in front of the ASA firewall on the security module (see
on page 143 ).
Note
You must install the same software type on all modules in a chassis; different software types are not supported at this time. Note that modules can run different versions of a particular device type, but all modules must be configured as the same type of logical device.
Before You Begin
• If the security module/engine that you want to use for the logical device already has a logical device configured on it, you must first delete the existing logical device (see
Delete a Logical Device, on page
148 ).
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
123
Logical Devices
Create a Standalone ASA Logical Device
• Download the application image you want to use for the logical device from Cisco.com (see
Images from Cisco.com, on page 34
) and then upload that image to the FXOS chassis (see
Uploading an Image to the Firepower Security Appliance, on page 34
).
• Configure a management interface to use with the logical device.
• You can only deploy a routed firewall mode ASA from the FXOS chassis. To change the ASA to transparent firewall mode, complete this procedure, and then see
Change the ASA to Transparent Firewall
.
Procedure
Step 1
Choose
Logical Devices
to open the Logical Devices page.
The Logical Devices page shows a list of configured logical devices on the chassis. If no logical devices have been configured, a message stating so is shown instead.
Step 2
Click
Add Device
to open the
Add Device
dialog box.
Step 3
For the
Device Name
, provide a name for the logical device.
Step 4
For the
Template
, choose
Cisco Adaptive Security Appliance
.
Step 5
For the
Image Version
, choose the ASA software version.
Step 6
For the
Device Mode
, click the
Standalone
radio button.
Step 7
Click
OK
.
You see the Provisioning -
device name
window.
Step 8
Expand the
Data Ports
area, and click each port that you want to assign to the device.
Step 9
Click the device icon in the center of the screen.
The ASA Configuration dialog box appears.
Step 10
On the
General Information
tab, complete the following: a) On multiple module devices, like the Firepower 9300, choose the security module that you want to use for this logical device by clicking on it under Security Module Selection.
b) Select the management interface to use with the logical device from the
Management Interface
drop-down list.
c) Under DEFAULT, configure the management interface:
This information is used to configure a management interface in the security module/engine configuration.
This management IP address is also the IP address you will use to connect to ASDM.
1
Select the type of address from the
Address Type
drop-down list.
2
In the
Management IP
field, configure a local IP address.
3
Enter a
Network Mask
or
Prefix Length
.
4
Enter a
Network Gateway
address.
Step 11
On the
Settings
tab, enter a password for the "admin" user in the
Password
field.
Step 12
Click
OK
to close the ASA Configuration dialog box.
Step 13
Click
Save
.
124
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Create a Standalone Threat Defense Logical Device
The Firepower eXtensible Operating System deploys the logical device by downloading the specified software version and pushing the bootstrap configuration and management interface settings to the specified security module/engine.
Create a Standalone Threat Defense Logical Device
You can create a standalone logical device for each security module/engine installed in the FXOS chassis.
On multiple module devices, like the Firepower 9300, you cannot create standalone logical devices if you have a cluster configured. You will need to delete the cluster before you can configure a standalone device.
Note
You must install the same software type on all modules in a chassis; different software types are not supported at this time. Note that modules can run different versions of a particular device type, but all modules must be configured as the same type of logical device.
Before You Begin
• If the security module/engine that you want to use for the logical device already has a logical device configured on it, you must first delete the existing logical device (see
Delete a Logical Device, on page
148 ).
• Download the application image you want to use for the logical device from Cisco.com (see
Images from Cisco.com, on page 34
) and then upload that image to the FXOS chassis (see
Uploading an Image to the Firepower Security Appliance, on page 34
).
• Configure a management interface to use with the logical device. You must also configure at least one
Data type interface. Optionally, you can also create a firepower-eventing interface to carry all event traffic (such as web events).
Procedure
Step 1
Choose
Logical Devices
to open the Logical Devices page.
The Logical Devices page shows a list of configured logical devices on the chassis. If no logical devices have been configured, a message stating so is shown instead.
Step 2
Click
Add Device
to open the
Add Device
dialog box.
Step 3
For the
Device Name
, provide a name for the logical device.
This name is used by the FXOS chassis supervisor to configure management settings and to assign interfaces; it is not the device name used in the security module/engine configuration.
Step 4
For the
Template
, choose
Cisco Firepower Threat Defense
.
Step 5
For the
Image Version
, choose the Threat Defense software version.
Step 6
For the
Device Mode
, click the
Standalone
radio button.
Step 7
Click
OK
.
You see the Provisioning -
device name
window.
Step 8
Expand the
Data Ports
area, and click each port that you want to assign to the device.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
125
Logical Devices
Create a Standalone Threat Defense Logical Device
Hardware Bypass-capable ports are shown with the following icon: . If you do not assign both interfaces in a Hardware Bypass pair, you see a warning message to make sure your assignment is intentional. You do not need to use the Hardware Bypass feature, so you can assign single interfaces if you prefer.
Step 9
Click the device icon in the center of the screen.
The configuration dialog box appears.
Step 10
On the
General Information
tab, complete the following: a) On multiple module devices, like the Firepower 9300, choose the security module that you want to use for this logical device by clicking on it under Security Module Selection.
b) Select the management interface to use with the logical device from the
Management Interface
drop-down list.
If you assign a Hardware Bypass-capable interface as the Management interface, you see a warning message to make sure your assignment is intentional.
c) Under Management, configure the management interface:
1
Select the type of address from the
Address Type
drop-down list.
2
In the
Management IP
field, configure a local IP address.
3
Enter a
Network Mask
or
Prefix Length
.
4
Enter a
Network Gateway
address.
Step 11
On the
Settings
tab, complete the following: a) In the
Registration Key
field, enter the key to be shared between Firepower Management Center and the device during registration.
b) In the
Password
field, enter a password for the device.
c) In the
Firepower Management Center IP
field, enter the IP address of the managing Firepower
Management Center.
d) In the
Search Domains
field, enter a comma-separated list of search domains for the device.
e) Choose the firewall mode: Transparent or Routed.
f) In the
DNS Servers
field, enter a comma-separated list of DNS servers for the device to use.
g) In the
Fully Qualified Hostname
field, enter a fully qualified name for the Threat Defense device.
h) Choose the interface on which Firepower events should be sent. If not specified, the management interface will be used.
To specify an interface to use for Firepower events, you must configure an interface as a
firepower-eventing
interface. For more information, see
About Firepower Security Appliance Interfaces, on page 113
.
Step 12
On the
Agreement
tab, read and accept the end user license agreement (EULA).
Step 13
Click
OK
to close the configuration dialog box.
Step 14
Click
Save
.
The Firepower eXtensible Operating System deploys the logical device by downloading the specified software version and pushing the bootstrap configuration and management interface settings to the specified security module/engine.
126
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Deploy a Cluster
Deploy a Cluster
Clustering lets you group multiple devices together as a single logical device. A cluster provides all the convenience of a single device (management, integration into a network) while achieving the increased throughput and redundancy of multiple devices. The Firepower 9300, which includes multiple modules, supports intra-chassis clustering where you group all modules within a single chassis into a cluster. You can also use inter-chassis clustering, where multiple chassis are grouped together; inter-chasis clustering is the only option for single module devices like the Firepower 4100 series.
Note
The Firepower Threat Defense does not support a cluster across multiple chassis (inter-chassis); only intra-chassis clustering is supported.
About Clustering on the FXOS Chassis
The cluster consists of multiple devices acting as a single logical unit. When you deploy a cluster on the FXOS chassis, it does the following:
• Creates a
cluster-control link
(by default, port-channel 48) for unit-to-unit communication. For intra-chassis clustering (Firepower 9300 only), this link utilizes the Firepower 9300 backplane for cluster communications. For inter-chassis clustering, you need to manually assign physical interface(s) to this
EtherChannel for communications between chassis.
• Creates the cluster bootstrap configuration within the application.
When you deploy the cluster, the FXOS chassis supervisor pushes a minimal bootstrap configuration to each unit that includes the cluster name, cluster control link interface, and other cluster settings. Some parts of the bootstrap configuration may be user-configurable within the application if you want to customize your clustering environment.
• Assigns data interfaces to the cluster as
Spanned
interfaces.
For intra-chassis clustering, spanned interfaces are not limited to EtherChannels, like it is for inter-chassis clustering.The Firepower 9300 supervisor uses EtherChannel technology internally to load-balance traffic to multiple modules on a shared interface, so any data interface type works for Spanned mode.
For inter-chassis clustering, you must use Spanned EtherChannels for all data interfaces.
Note
Individual interfaces are not supported, with the exception of a management interface.
• Assigns a management interface to all units in the cluster.
The following sections provide more detail about clustering concepts and implementation.
Primary and Secondary Unit Roles
One member of the cluster is the primary unit. The primary unit is determined automatically. All other members are secondary units.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
127
Logical Devices
About Clustering on the FXOS Chassis
You must perform all configuration on the primary unit only; the configuration is then replicated to the secondary units.
Cluster Control Link
The cluster control link is automatically created using the Port-channel 48 interface. For intra-chassis clustering, this interface has no member interfaces. For inter-chassis clustering, you must add one or more interfaces to the EtherChannel. This Cluster type EtherChannel utilizes the Firepower 9300 backplane for cluster communications for intra-chassis clustering.
For a 2-member inter-chassis cluster, do not directly connect the cluster control link from one chassis to the other chassis. If you directly connect the interfaces, then when one unit fails, the cluster control link fails, and thus the remaining healthy unit fails. If you connect the cluster control link through a switch, then the cluster control link remains up for the healthy unit.
Cluster control link traffic includes both control and data traffic.
Size the Cluster Control Link for Inter-Chassis Clustering
If possible, you should size the cluster control link to match the expected throughput of each chassis so the cluster-control link can handle the worst-case scenarios.
Cluster control link traffic is comprised mainly of state update and forwarded packets. The amount of traffic at any given time on the cluster control link varies. The amount of forwarded traffic depends on the load-balancing efficacy or whether there is a lot of traffic for centralized features. For example:
• NAT results in poor load balancing of connections, and the need to rebalance all returning traffic to the correct units.
• When membership changes, the cluster needs to rebalance a large number of connections, thus temporarily using a large amount of cluster control link bandwidth.
A higher-bandwidth cluster control link helps the cluster to converge faster when there are membership changes and prevents throughput bottlenecks.
Note
If your cluster has large amounts of asymmetric (rebalanced) traffic, then you should increase the cluster control link size.
Cluster Control Link Redundancy for Inter-Chassis Clustering
The following diagram shows how to use an EtherChannel as a cluster control link in a Virtual Switching
System (VSS) or Virtual Port Channel (vPC) environment. All links in the EtherChannel are active. When the switch is part of a VSS or vPC, then you can connect FXOS chassis interfaces within the same EtherChannel to separate switches in the VSS or vPC. The switch interfaces are members of the same EtherChannel port-channel interface, because the separate switches act like a single switch. Note that this EtherChannel is device-local, not a Spanned EtherChannel.
128
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
About Clustering on the FXOS Chassis
Cluster Control Link Reliability for Inter-Chassis Clustering
To ensure cluster control link functionality, be sure the round-trip time (RTT) between units is less than 20 ms. This maximum latency enhances compatibility with cluster members installed at different geographical sites. To check your latency, perform a ping on the cluster control link between units.
The cluster control link must be reliable, with no out-of-order or dropped packets; for example, for inter-site deployment, you should use a dedicated link.
Cluster Control Link Network
The FXOS chassis auto-generates the cluster control link interface IP address for each unit based on the chassis
ID and slot ID: 127.2.
chassis_id
.
slot_id
. You cannot set this IP address manually, either in FXOS or within the application. The cluster control link network cannot include any routers between units; only Layer 2 switching is allowed. For inter-site traffic, Cisco recommends using Overlay Transport Virtualization (OTV).
Management Network
We recommend connecting all units to a single management network. This network is separate from the cluster control link.
Management Interface
You can assign a Management type interface to the cluster. This interface is a special
individual
interface as opposed to a Spanned interface. The management interface lets you connect directly to each unit.
For the ASA, the Main cluster IP address is a fixed address for the cluster that always belongs to the current primary unit. You also configure a range of addresses so that each unit, including the current primary unit, can use a Local address from the range. The Main cluster IP address provides consistent management access to an address; when a primary unit changes, the Main cluster IP address moves to the new primary unit, so management of the cluster continues seamlessly. The Local IP address is used for routing, and is also useful for troubleshooting. For example, you can manage the cluster by connecting to the Main cluster IP address, which is always attached to the current primary unit. To manage an individual member, you can connect to the Local IP address. For outbound management traffic such as TFTP or syslog, each unit, including the primary unit, uses the Local IP address to connect to the server.
For the Firepower Threat Defense, assign a management IP address to each unit on the same network. Use these IP addresses when you add each unit to the Management Center.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
129
Logical Devices
About Clustering on the FXOS Chassis
Spanned EtherChannels
You can group one or more interfaces per chassis into an EtherChannel that spans all chassis in the cluster.
The EtherChannel aggregates the traffic across all the available active interfaces in the channel. A Spanned
EtherChannel can be configured in both routed and transparent firewall modes. In routed mode, the
EtherChannel is configured as a routed interface with a single IP address. In transparent mode, the IP address is assigned to the BVI, not to the bridge group member interface. The EtherChannel inherently provides load balancing as part of basic operation.
Inter-Site Clustering
For inter-site installations, you can take advantage of clustering as long as you follow the recommended guidelines.
You can configure each cluster chassis to belong to a separate site ID.
Site IDs work with site-specific MAC addresses and IP addresses. Packets sourced from the cluster use a site-specific MAC address and IP address, while packets received by the cluster use a global MAC address and IP address. This feature prevents the switches from learning the same global MAC address from both sites on two different ports, which causes MAC flapping; instead, they only learn the site MAC address.
Site-specific MAC addresses and IP address are supported for routed mode using Spanned EtherChannels only.
Site IDs are also used to enable flow mobility using LISP inspection.
See the following sections for more information about inter-site clustering:
• Sizing the Data Center Interconnect
— Prerequisites for Clustering, on page 131
• Inter-Site Guidelines —
Guidelines for Clustering, on page 132
•
Inter-Site Examples
Examples for Inter-Site Clustering, on page 140
130
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Prerequisites for Clustering
Prerequisites for Clustering
Inter-Chassis Hardware and Software Requirements
All chassis in a cluster:
• For the Firepower 4100 series: All chassis must be the same model. For the Firepower 9300: All security modules must be the same type. You can have different quantities of installed security modules in each chassis, although all modules present in the chassis must belong to the cluster including any empty slots.
• Must run the identical FXOS software except at the time of an image upgrade.
• Must include the same interface configuration for interfaces you assign to the cluster, such as the same
Management interface, EtherChannels, active interfaces, speed and duplex, and so on. You can use different network module types on the chassis as long as the capacity matches for the same interface
IDs and interfaces can successfully bundle in the same spanned EtherChannel. Note that all data interfaces must be EtherChannels in inter-chassis clustering.
• Must use the same NTP server. Do not set the time manually.
• Must be registered with the License Authority when using the ASA; for Firepower Threat Defense, all licensing is handled by the Firepower Management Center.
Switch Prerequisites for Inter-Chassis Clustering
• Be sure to complete the switch configuration and successfully connect all the EtherChannels from the chassis to the switch(es) before you configure clustering on the FXOS chassis.
• For a list of supported switches, see Cisco FXOS Compatibility .
Sizing the Data Center Interconnect for Inter-Site Clustering
You should reserve bandwidth on the data center interconnect (DCI) for cluster control link traffic equivalent to the following calculation:
If the number of members differs at each site, use the larger number for your calculation. The minimum bandwidth for the DCI should not be less than the size of the cluster control link for one member.
For example:
• For 4 members at 2 sites:
◦ 4 cluster members total
◦ 2 members at each site
◦ 5 Gbps cluster control link per member
Reserved DCI bandwidth = 5 Gbps (2/2 x 5 Gbps).
• For 6 members at 3 sites, the size increases:
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
131
Logical Devices
Guidelines for Clustering
◦ 6 cluster members total
◦ 3 members at site 1, 2 members at site 2, and 1 member at site 3
◦ 10 Gbps cluster control link per member
Reserved DCI bandwidth = 15 Gbps (3/2 x 10 Gbps).
• For 2 members at 2 sites:
◦ 2 cluster members total
◦ 1 member at each site
◦ 10 Gbps cluster control link per member
Reserved DCI bandwidth = 10 Gbps (1/2 x 10 Gbps = 5 Gbps; but the minimum bandwidth should not be less than the size of the cluster control link (10 Gbps)).
Guidelines for Clustering
Models
•
ASA on the Firepower 9300
—
Supported for intra-chassis, inter-chassis, and inter-site clustering.
•
ASA on the Firepower 4100 series
—
Supported for inter-chassis and inter-site clustering.
• Firepower Threat Defense on the Firepower 9300 — Supported for intra-chassis clustering.
• Radware DefensePro — Supported for intra-chassis clustering with the ASA.
Switches for Inter-Chassis Clustering
• For the ASR 9006, if you want to set a non-default MTU, set the ASR interface MTU to be 14 bytes higher than the cluster device MTU. Otherwise, OSPF adjacency peering attempts may fail unless the
mtu-ignore
option is used. Note that the cluster device MTU should match the ASR
IPv4
MTU.
• On the switch(es) for the cluster control link interfaces, you can optionally enable Spanning Tree PortFast on the switch ports connected to the cluster unit to speed up the join process for new units.
• When you see slow bundling of a Spanned EtherChannel on the switch, you can enable LACP rate fast for an individual interface on the switch.
• On the switch, we recommend that you use one of the following EtherChannel load-balancing algorithms:
source-dest-ip
or
source-dest-ip-port
(see the Cisco Nexus OS and Cisco IOS
port-channel load-balance
command). Do not use a
vlan
keyword in the load-balance algorithm because it can cause unevenly distributed traffic to the devices in a cluster.
Do not
change the load-balancing algorithm from the default on the cluster device.
• If you change the load-balancing algorithm of the EtherChannel on the switch, the EtherChannel interface on the switch temporarily stops forwarding traffic, and the Spanning Tree Protocol restarts. There will be a delay before traffic starts flowing again.
132
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Guidelines for Clustering
• Switches on the cluster control link path should not verify the L4 checksum. Redirected traffic over the cluster control link does not have a correct L4 checksum. Switches that verify the L4 checksum could cause traffic to be dropped.
• Port-channel bundling downtime should not exceed the configured keepalive interval.
• On Supervisor 2T EtherChannels, the default hash distribution algorithm is adaptive. To avoid asymmetric traffic in a VSS design, change the hash algorithm on the port-channel connected to the cluster device to fixed: router(config)# port-channel id hash-distribution fixed
Do not change the algorithm globally; you may want to take advantage of the adaptive algorithm for the
VSS peer link.
EtherChannels for Inter-Chassis Clustering
• For connecting switches, set the EtherChannel mode to Active; On mode is not supported on the FXOS chassis, even for the cluster control link.
• FXOS EtherChannels have the LACP rate set to normal by default. This setting can make port-channel members take more than 30 seconds to bundle, which can cause the cluster interface health check to fail causing the unit to be removed from the cluster. We recommend that you change the LACP rate to fast.
The following example modifies the "default" lacp policy: firepower#
scope org
firepower /org #
scope lacppolicy default
firepower /org/lacppolicy#
set lacp-rate fast
firepower /org* #
commit-buffer
• In Catalyst 3750-X Cisco IOS software versions earlier than 15.1(1)S2, the cluster unit did not support connecting an EtherChannel to a switch stack. With default switch settings, if the cluster unit EtherChannel is connected cross stack, and if the master switch is powered down, then the EtherChannel connected to the remaining switch will not come up. To improve compatibility, set the
stack-mac persistent timer
command to a large enough value to account for reload time; for example, 8 minutes or 0 for indefinite.
Or, you can upgrade to more a more stable switch software version, such as 15.1(1)S2.
•
Spanned vs. Device-Local EtherChannel Configuration
—
Be sure to configure the switch appropriately for Spanned EtherChannels vs. Device-local EtherChannels.
◦
Spanned EtherChannels
—
For cluster unit
Spanned
EtherChannels, which span across all members of the cluster, the interfaces are combined into a single EtherChannel on the switch. Make sure each interface is in the same channel group on the switch.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
133
Guidelines for Clustering
Logical Devices
◦ Device-local EtherChannels — For cluster unit
Device-local
EtherChannels including any
EtherChannels configured for the cluster control link, be sure to configure discrete EtherChannels on the switch; do not combine multiple cluster unit EtherChannels into one EtherChannel on the switch.
134
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Defaults for Clustering
Additional Guidelines
• We recommend connecting EtherChannels to a VSS or vPC for redundancy.
• Within a chassis, you cannot cluster some security modules and run other security modules in standalone mode; you must include all security modules in the cluster.
Defaults for Clustering
The cluster control link uses Port-channel 48.
Configure ASA Clustering
You can easily deploy the cluster from the FXOS chassis supervisor. All initial configuration is automatically generated for each unit. For inter-chassis clustering, you must configure each chassis separately. Deploy the cluster on one chassis; you can then copy the bootstrap configuration from the first chassis to the next chassis for ease of deployment.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
135
Logical Devices
Configure ASA Clustering
Before You Begin
• You must enable clustering for all 3 module slots in a Firepower 9300 chassis, even if you do not have a module installed. If you do not configure all 3 modules, the cluster will not come up.
• On the
Interfaces
tab, the port-channel 48 cluster type interface shows the
Operation State
as
failed
if it does not include any member interfaces. For intra-chassis clustering, this EtherChannel does not require any member interfaces, and you can ignore this Operational State.
• You can only deploy a routed firewall mode ASA cluster from the FXOS chassis. To change the ASA cluster to transparent firewall mode, complete this procedure, and then see
.
Procedure
Step 1
Add at least one Data type interface or EtherChannel (also known as a port-channel) before you deploy the cluster. See
Create a Port Channel, on page 117
or
Edit Interface Properties, on page 116
.
You can also add data interfaces to the cluster after you deploy it.
For inter-chassis clustering, all data interfaces must be EtherChannels with at least one member interface.
Add the same EtherChannels on each chassis.
Step 2
Add a Management type interface or EtherChannel. See
Create a Port Channel, on page 117
or
.
For inter-chassis clustering, add the same Management interface on each chassis.
Step 3
For inter-chassis clustering, add a member interface to port-channel 48, which is used as the cluster control link.
If you do not include a member interface, then when you deploy the logical device, the Firepower Chassis
Manager assumes that this cluster is an intra-chassis cluster and does not show the
Chassis ID
field. Add the same member interfaces on each chassis.
Step 4
Choose
Logical Devices
to open the Logical Devices page.
The Logical Devices page shows a list of configured logical devices on the chassis. If no logical devices have been configured, a message stating so is shown instead.
Step 5
Click
Add Device
to open the
Add Device
dialog box.
If you have an existing cluster, you are prompted to remove the cluster and add a new one. All cluster-related configuration on the security modules will be replaced by the new information.
Step 6
For the
Device Name
, provide a name for the logical device. This name is used by the FXOS chassis supervisor to configure clustering settings and assign interfaces; it is not the cluster name used in the security module configuration.
Step 7
For the
Template
, choose
Cisco Adaptive Security Appliance
.
Step 8
For the
Image Version
, choose the ASA software version.
Step 9
For the
Device Mode
, click the
Cluster
radio button.
Step 10
Click the
Create New Cluster
radio button.
Step 11
Click
OK
.
If you have any standalone devices configured, you are prompted to replace them with a new cluster. You see the Provisioning -
device name
window.
All interfaces are assigned to the cluster by default.
136
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Configure ASA Clustering
Step 12
Click the device icon in the center of the screen.
The ASA Configuration dialog box appears with the
Cluster Information
tab selected.
Step 13
In the
Chassis ID
field, enter a chassis ID. Each chassis in the cluster must use a unique ID.
Step 14
In the
Cluster Key
field, configure an authentication key for control traffic on the cluster control link.
The shared secret is an ASCII string from 1 to 63 characters. The shared secret is used to generate the key.
This option does not affect datapath traffic, including connection state update and forwarded packets, which are always sent in the clear.
Step 15
Set the
Cluster Group Name
, which is the cluster group name in the security module configuration.
The name must be an ASCII string from 1 to 38 characters.
Step 16
Click
Management Interface
and choose the management interface you created earlier.
Step 17
Choose the
Address Type
for the management interface.
This information is used to configure a management interface in the security module configuration.
a) In the
Management IP Pool
field, configure a pool of Local IP addresses, one of which will be assigned to each cluster unit for the interface, by entering the starting and ending addresses separated by a hyphen.
Include at least as many addresses as there are units in the cluster. Note that for the Firepower 9300, you must include 3 addresses per chassis, even if you do not have all module slots filled. If you plan to expand the cluster, include additional addresses. The Virtual IP address (known as the Main cluster IP address) that belongs to the current primary unit is
not
a part of this pool; be sure to reserve an IP address on the same network for the Main cluster IP address. You can use IPv4 and/or IPv6 addresses.
b) Enter a
Network Mask
or
Prefix Length
.
c) Enter a
Network Gateway
.
d) Enter a
Virtual IP address
.
This IP address must be on the same network as the cluster pool addresses, but not be part of the pool.
Step 18
On the
Settings
tab, for the
Password
, enter a password for the "admin" user.
Step 19
Click
OK
to close the ASA Configuration dialog box.
Step 20
Click
Save
.
The FXOS chassis supervisor deploys the cluster by downloading the specified software version and pushing the cluster bootstrap configuration and management interface settings to each security module.
Step 21
For inter-chassis clustering, add the next chassis to the cluster: a) On the first chassis Firepower Chassis Manager, click the
Show Cluster Details
icon at the top right; copy the displayed cluster configuration.
b) Connect to the Firepower Chassis Manager on the next chassis, and add a logical device according to this procedure.
c) Choose
Join an Existing Cluster
.
d) Click the
Copy config
check box, and click
OK
. If you uncheck this check box, you must manually enter the settings to match the first chassis configuration.
e) In the
Copy Cluster Details
box, paste in the cluster configuration from the first chassis, and click
OK
.
f) Click the device icon in the center of the screen. The cluster information is mostly pre-filled, but you must change the following settings:
•
Chassis ID
— Enter a unique chassis ID.
•
Cluster Key
—
(Not prefilled) Enter the same cluster key.
Click
OK
.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
137
Logical Devices
Configure Firepower Threat Defense Clustering
g) Click
Save
.
Step 22
Connect to the primary unit security module to customize your clustering configuration.
Configure Firepower Threat Defense Clustering
You can easily deploy the cluster from the FXOS chassis supervisor. All initial configuration is automatically generated for each unit.
Before You Begin
• You must enable clustering for all 3 module slots in a Firepower 9300 chassis, even if you do not have a module installed. If you do not configure all 3 modules, the cluster will not come up.
• On the
Interfaces
tab, the port-channel 48 cluster type interface shows the
Operation State
as
failed
if it does not include any member interfaces. For intra-chassis clustering, this EtherChannel does not require any member interfaces, and you can ignore this Operational State.
Procedure
Step 1
Add at least one Data type interface or EtherChannel (also known as a port-channel) before you deploy the cluster.
You can also add data interfaces to the cluster after you deploy it.
Step 2
Add a Management type interface or EtherChannel.
Step 3
(Optional) Add a Firepower-eventing interface.
This interface is a secondary management interface for Firepower Threat Defense devices. To use this interface, you must configure its IP address and other parameters at the Firepower Threat Defense CLI. For example, you can separate management traffic from events (such as web events). See the
configure network
commands in the Firepower Threat Defense command reference.
Step 4
Choose
Logical Devices
to open the
Logical Devices
page.
The
Logical Devices
page shows a list of configured logical devices on the chassis. If no logical devices have been configured, a message stating so is shown instead.
Step 5
Click
Add Device
to open the
Add Device
dialog box.
If you have an existing logical device, you are prompted to remove the device and add a new one. All configuration on the security modules will be replaced by the new information.
Step 6
For the
Device Name
, provide a name for the logical device. This name is used by the FXOS chassis supervisor to configure clustering/management settings and to assign interfaces; it is not the cluster name used in the logical device configuration.
Step 7
For the
Template
, choose
Cisco Firepower Threat Defense
.
Step 8
For the
Image Version
, choose the Firepower Threat Defense software version. Make sure this version is compatible with your FXOS version and with the Firepower Management Center version.
Step 9
For the
Device Mode
, click the
Cluster
radio button.
Step 10
Click
OK
.
138
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Configure Firepower Threat Defense Clustering
If you have any standalone devices configured, you are prompted to replace them with a new cluster. You see the Provisioning - device name window.
All interfaces are assigned to the cluster by default. Hardware Bypass-capable ports are shown with the following icon: . If you do not assign both interfaces in a Hardware Bypass pair, you see a warning message to make sure your assignment is intentional. You do not need to use the Hardware Bypass feature, so you can assign single interfaces if you prefer.
Step 11
Click the device icon in the center of the screen.
The
Cisco Firepower Threat Defense Configuration
dialog box appears.
Step 12
On the
Cluster Information
tab, complete the following: a) In the
Cluster Key
field, configure an authentication key for control traffic on the cluster control link.
The shared secret is an ASCII string from 1 to 63 characters. The shared secret is used to generate the key.
This option does not affect datapath traffic, including connection state update and forwarded packets, which are always sent in the clear.
b) Set the
Cluster Group Name
, which is the cluster group name in the logical device configuration.
The name must be an ASCII string from 1 to 38 characters.
c) Select the management interface to use with the logical device from the
Management Interface
drop-down list.
If you assign a Hardware Bypass-capable interface as the Management interface, you see a warning message to make sure your assignment is intentional.
Step 13
On the
Settings
tab, complete the following: a) In the
Registration Key
field, enter the key to be shared between the Firepower Management Center and the cluster members during registration.
b) In the
Password
field, enter a password for the admin user on the cluster.
c) In the
Firepower Management Center IP
field, enter the IP address of the managing Firepower
Management Center.
d) In the
Search Domains
field, enter a comma-separated list of search domains for the management network.
e) From the
Firewall Mode
drop-down list, choose
Transparent
or
Routed
.
f) In the
DNS Servers
field, enter a comma-separated list of DNS servers that the Firepower Threat Defense device should use on the management network.
g) In the
Fully Qualified Hostname
field, enter a fully qualified name for the Firepower Threat Defense device.
h) From the
Eventing Interface
drop-down list, choose the interface on which Firepower events should be sent. If not specified, the management interface will be used.
To specify a separate interface to use for Firepower events, you must configure an interface as a
firepower-eventing
interface. If you assign a Hardware Bypass-capable interface as the Eventing interface, you see a warning message to make sure your assignment is intentional.
Step 14
On the
Interface Information
tab, configure a management IP address for each security module in the cluster.
Select the type of address from the
Address Type
drop-down list and then complete the following for each security module.
Note
You must set the IP address for all 3 module slots in a chassis, even if you do not have a module installed. If you do not configure all 3 modules, the cluster will not come up.
a) In the
Management IP
field, configure an IP address.
Specify an IP address on the same network for each module.
b) Enter a
Network Mask
or
Prefix Length
.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
139
Logical Devices
Examples for Inter-Site Clustering
c) Enter a
Network Gateway
address.
Step 15
On the
Agreement
tab, read and accept the end user license agreement (EULA).
Step 16
Click
OK
to close the
Cisco Firepower Threat Defense Configuration
dialog box.
Step 17
Click
Save
.
The FXOS chassis supervisor deploys the cluster by downloading the specified software version and pushing the cluster bootstrap configuration and management interface settings to each security module.
Step 18
Add each unit separately to the Firepower Management Center using the management IP addresses, and then group them into a cluster at the web interface.
All cluster units must be in a successfully-formed cluster on FXOS prior to adding them to Firepower
Management Center.
Examples for Inter-Site Clustering
The following examples show supported cluster deployments.
Spanned EtherChannel Transparent Mode North-South Inter-Site Example
The following example shows 2 cluster members at each of 2 data centers placed between inside and outside routers (North-South insertion). The cluster members are connected by the cluster control link over the DCI.
The cluster members at each site connect to the local switches using spanned EtherChannels for the inside and outside. Each EtherChannel is spanned across all chassis in the cluster.
The inside and outside routers at each data center use OSPF, which is passed through the transparent ASAs.
Unlike MACs, router IPs are unique on all routers. By assigning a higher cost route across the DCI, traffic stays within each data center unless all cluster members at a given site go down. The lower cost route through the ASAs must traverse the same bridge group at each site for the cluster to maintain asymmetric connections.
In the event of a failure of all cluster members at one site, traffic goes from each router over the DCI to the cluster members at the other site.
The implementation of the switches at each site can include:
• Inter-site VSS/vPC — In this scenario, you install one switch at Data Center 1, and the other at Data
Center 2. One option is for the cluster units at each Data Center to only connect to the local switch, while the VSS/vPC traffic goes across the DCI. In this case, connections are for the most part kept local to each datacenter. You can optionally connect each unit to both switches across the DCI if the DCI can handle the extra traffic. In this case, traffic is distributed across the data centers, so it is essential for the
DCI to be very robust.
• Local VSS/vPC at each site — For better switch redundancy, you can install 2 separate VSS/vPC pairs at each site. In this case, although the cluster units still have a spanned EtherChannel with Data Center
1 chassis connected only to both local switches, and Data Center 2 chassis connected to those local switches, the spanned EtherChannel is essentially
“ split.
”
Each local VSS/vPC sees the spanned
EtherChannel as a site-local EtherChannel.
140
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Examples for Inter-Site Clustering
Spanned EtherChannel Transparent Mode East-West Inter-Site Example
The following example shows 2 cluster members at each of 2 data centers placed between the gateway router and two inside networks at each site, the App network and the DB network (East-West insertion). The cluster members are connected by the cluster control link over the DCI. The cluster members at each site connect to the local switches using spanned EtherChannels for both the App and DB networks on the inside and outside.
Each EtherChannel is spanned across all chassis in the cluster.
The gateway router at each site uses an FHRP such as HSRP to provide the same destination virtual MAC and IP addresses at each site. A good practice to avoid unintended MAC address flapping is to statically add the gateway routers real MAC addresses to the ASA MAC address table. Without these entries, if the gateway at site 1 communicates with the gateway at site 2, that traffic might pass through the ASA and attempt to reach site 2 from the inside interface and cause problems. The data VLANs are extended between the sites using
Overlay Transport Virtualization (OTV) (or something similar). You must add filters to prevent traffic from traversing the DCI to the other site when the traffic is destined for the gateway router. If the gateway router at one site becomes unreachable, you must remove the filters so traffic can be sent to the other site
’ s gateway router.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
141
History for Clustering
Logical Devices
See
Spanned EtherChannel Transparent Mode North-South Inter-Site Example, on page 140
for information about vPC/VSS options.
History for Clustering
Feature Name Platform
Releases
Intra-chassis Clustering for the Cisco ASA
1.1.1
Feature Information
You can cluster all ASA security modules within the Firepower 9300 chassis.
We introduced the following screen:
Logical Devices
>
Configuration
Inter-chassis clustering for
6 ASA modules
1.1.3
Support for intra-chassis clustering on the
Firepower Threat Defense on the Firepower 9300
1.1.4
You can now enable inter-chassis clustering for the ASA. You can include up to 6 modules in up to 6 chassis.
We modified the following screen:
Logical Devices
>
Configuration
The Firepower 9300 supports intra-chassis clustering with the Firepower Threat Defense application.
We modified the following screen:
Logical Devices
>
Configuration
142
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Configure Service Chaining
Configure Service Chaining
The Cisco FXOS chassis can support multiple services (for example, a firewall and a third-party DDoS application) on a single blade. These applications and services can be linked together to form a Service Chain.
About Service Chaining
In the current supported Service Chaining configuration, the third-party Radware DefensePro virtual platform runs in front of the ASA firewall. Radware DefensePro is a KVM-based virtual platform that provides distributed denial-of-service (DDoS) detection and mitigation capabilities on the FXOS chassis. When Service
Chaining is enabled on your FXOS chassis, traffic from the network must first pass through the DefensePro virtual platform before reaching the main ASA firewall.
The Radware DefensePro virtual platform may be referred to as
Radware vDP
(virtual DefensePro), or simply
vDP
. The Radware DefensePro virtual platform may occasionally be referred to as a Link Decorator.
Prerequisites for Service Chaining
Prior to deploying Radware DefensePro on your FXOS chassis, you must configure the FXOS chassis to use an NTP Server with the
etc/UTC
Time Zone. For more information about setting the date and time in your
FXOS chassis, see
Setting the Date and Time, on page 79
.
Guidelines for Service Chaining
Models
• The Radware DefensePro platform is supported with ASA on the following security appliances:
◦ Firepower 9300
◦ Firepower 4120 - You must use the CLI to deploy Radware DefensePro on this platform; the
Firepower Chassis Manager does not yet support this functionality.
◦ Firepower 4140 - You must use the CLI to deploy Radware DefensePro on this platform; the
Firepower Chassis Manager does not yet support this functionality.
◦ Firepower 4150
Note
The Radware DefensePro platform is not currently supported with ASA on Firepower
4110 devices.
Additional Guidelines
• The DefensePro application can run as separate instances on up to three security modules.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
143
Logical Devices
Configure Radware DefensePro Service Chain on a Standalone Logical Device
Configure Radware DefensePro Service Chain on a Standalone Logical Device
The following procedure shows how to install Radware DefensePro in a single Service Chain in front of a standalone ASAlogical device.
Note
If you are installing Radware vDP in front of ASA on a 4120 security appliance, you must use the FXOS
CLI to deploy the decorator. For full CLI instructions on how to install and configure Radware DefensePro in a service chain in front of ASA on Firepower 4100 devices, refer to the FXOS CLI configuration guide.
If you are installing Radware vDP in front of Firepower Threat Defense on any Firepower device, you must use the FXOS CLI to deploy the decorator. For full CLI instructions on how to install and configure
Radware DefensePro in a service chain in front of Firepower Threat Defense on Firepower 4100 or
Firepower 9300 devices, refer to the FXOS CLI configuration guide.
Before You Begin
• Download the vDP image from Cisco.com (see
Downloading Images from Cisco.com, on page 34
) and then upload that image to the FXOS chassis (see
Uploading an Image to the Firepower Security
).
• You can deploy the Radware DefensePro application in a standalone configuration on an intra-chassis cluster; for intra-chassis clustering, see
Configure Radware DefensePro Service Chain on an Intra-Chassis
.
Procedure
Step 1
If you want to use a separate management interface for vDP, enable the interface and set it to be the mgmt type according to
Edit Interface Properties, on page 116
. Otherwise, you can share the application management interface.
Step 2
Choose
Logical Devices
to open the Logical Devices page.
The Logical Devices page shows a list of configured logical devices on the chassis. If no logical devices have been configured, a message stating so is shown.
Step 3
Create a standalone ASA Logical Device (see
Create a Standalone ASA Logical Device, on page 123
).
Note that before you click
Save
at the end of the procedure to create a standaolone ASA logical device, you must first follow the following steps to add a vDP decorator to the logical device.
Step 4
In the
Decorators
area, select vDP. The Radware: Virtual DefensePro - Configuration window appears.
Configure the following fields under the
General Information
tab.
Step 5
If you have more than one vDP version uploaded to the FXOS chassis, select the version you want to use in the
Version
drop-down.
Step 6
Under the
Management Interface
drop-down, choose the management interface you created in step 1 of this procedure.
Step 7
Select the default
Address Type
, IPv4 only, IPv6 only, or IPv4 and IPv6.
Step 8
Configure the following fields, based on your
Address Type
selection from the previous step.
a) In the
Management IP
field, configure a local IP address.
b) IPv4 only: Enter a
Network Mask
.
144
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Configure Radware DefensePro Service Chain on an Intra-Chassis Cluster
IPv6 only: Enter a
Prefix Length
.
c) Enter a
Network Gateway
address.
Step 9
Click the checkbox next to each data port that you want to assign to the device.
Step 10
Click
OK
.
Step 11
Click
Save
.
The Firepower eXtensible Operating System deploys the logical device by downloading the specified software version and pushing the bootstrap configuration and management interface settings to the specified security module.
Configure Radware DefensePro Service Chain on an Intra-Chassis Cluster
The following procedure shows how to install the Radware DefensePro image, and configure it in a Service
Chain in front of an ASA intra-chassis cluster.
Before You Begin
• Download the vDP image from Cisco.com (see
Downloading Images from Cisco.com, on page 34
) and then upload that image to the FXOS chassis (see
Uploading an Image to the Firepower Security
).
Procedure
Step 1
If you want to use a separate management interface for vDP, enable the interface and set it to be the mgmt type according to
Edit Interface Properties, on page 116
. Otherwise, you can share the application management interface.
Step 2
Configure an ASA intra-chassis cluster (see
Configure ASA Clustering, on page 135
).
Note that before you click
Save
at the end of the procedure to configure the intra-chassis cluster, you must first follow the following steps to add a vDP decorator to the cluster.
Step 3
In the
Decorators
area, select vDP. The
Radware: Virtual DefensePro - Configuration
dialog box appears.
Configure the following fields under the
General Information
tab.
Step 4
If you have more than one vDP version uploaded to the FXOS chassis, select the vDP version you want to use in the
Version
drop-down.
Step 5
Under the
Management Interface
drop-down, choose a management interface.
Step 6
Click the checkbox next to each data port that you want to assign to the vDP decorator.
Step 7
Click the
Interface Information
tab.
Step 8
Select the
Address Type
to be used, IPv4 only, IPv6 only, or IPv4 and IPv6.
Step 9
Configure the following fields for each Security Module. Note that the fields that display depend on your
Address Type
selection from the previous step.
a) In the
Management IP
field, configure a local IP address.
b) IPv4 only: Enter a
Network Mask
.
IPv6 only: Enter a
Prefix Length
.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
145
Logical Devices
Open UDP/TCP Ports and Enable vDP Web Services
c) Enter a
Network Gateway
address.
Step 10
Click
OK
.
Step 11
Click
Save
.
The Firepower eXtensible Operating System deploys the logical device by downloading the specified software version and pushing the bootstrap configuration and management interface settings to the specified security module.
Step 12
Choose
Logical Devices
to open the Logical Devices page.
Step 13
Scroll through the list of configured logical devices to the entries for vDP. Verify their Attributes listed in the
Management IP
column.
• If the
CLUSTER-ROLE
element displays as
unknown
for the DefensePro instances, you must enter the DefensePro application and configure the master IP address to complete the creation of the vDP cluster.
• If the
CLUSTER-ROLE
element displays as
primary
or
secondary
for the DefensePro instances, the applications are online and formed in a cluster.
Open UDP/TCP Ports and Enable vDP Web Services
The Radware APSolute Vision Manager interfaces communicate with the Radware vDP appliation using various UDP/TCP ports. In orer for the vDP application to communicate with the APSolute Vision Manager, you must ensure that these ports are accessible and not blocked by your firewall. For more information on which specific ports to open, see the following tables in the APSolute Vision User Guide:
•
Ports for APSolute Vision Server-WBM Communication and Operating System
•
Communication Ports for APSolute Vision Server with Radware Devices
In order for Radware APSolute Vision to manage the Virtual DefensePro application deployed on the FXOS chassis, you must enable the vDP web service using the FXOS CLI.
Procedure
Step 1
From the FXOS CLI, connect to the vDP application instance.
connect module slot console
connect vdp
Step 2
Enable vDP web services.
manage secure-web status set enable
Step 3
Exit the vDP application console and return to the FXOS module CLI.
Ctrl ]
146
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Manage Logical Devices
Manage Logical Devices
You can delete a logical device, convert an ASA to transparent mode, change the interface configuration, and perform other tasks on existing logical devices.
Connect to the Console of the Application or Decorator
Use the following procedure to connect to the console of the application or decorator.
Note
If you encounter any issues with accessing the console, we recommend that you try a different SSH client or upgrade your SSH client to a newer version.
Procedure
Step 1
To connect to the console of the application or decorator: a) From the FXOS CLI, connect to the security module/engine:
Firepower-chassis #
connect module slot_number console
Note
To connect to the security engine of a device that does not support multiple security modules, use 1 as the
slot_number
.
The first time you connect to the security module, you access the FXOS module CLI.
b) To connect to the application or decorator, enter the appropriate command for your device:
Firepower-module1>
connect asa
Firepower-module1>
connect ftd
Firepower-module1>
connect vdp
Subsequent connections from the supervisor level of the FXOS CLI to the security module/engine access the security module/engine OS directly.
Step 2
(Optional) Exit the application console to the FXOS module CLI by typing
Ctrl-A-D
.
Exit the decorator console to the FXOS module CLI by typing
Ctrl-]-
.
You might want to access the FXOS module CLI for troubleshooting purposes.
Step 3
Return to the supervisor level of the FXOS CLI.
a) To exit the security module/engine console, type
~
.
You exit to the Telnet application.
b) To exit the Telnet application, enter: telnet>
quit
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
147
Logical Devices
Delete a Logical Device
Example
The following example connects to an ASA on security module 1 and then exits back to the supervisor level of the FXOS CLI.
Firepower#
connect module 1 console
Telnet escape character is '~'.
Trying 127.5.1.1...
Connected to 127.5.1.1.
Escape character is '~'.
CISCO Serial Over LAN:
Close Network Connection to Exit
Firepower-module1>
connect asa
asa>
~
telnet>
quit
Connection closed.
Firepower#
Delete a Logical Device
Procedure
Step 1
Choose
Logical Devices
to open the Logical Devices page.
The Logical Devices page shows a list of configured logical devices on the chassis. If no logical devices have been configured, a message stating so is shown instead.
Step 2
Click
Delete
for the logical device that you want to delete.
Step 3
Click
Yes
to confirm that you want to delete the logical device.
Step 4
Click
Yes
to confirm that you want to delete the application configuration.
Change the ASA to Transparent Firewall Mode
You can only deploy a routed firewall mode ASA from the FXOS chassis. To change the ASA to transparent firewall mode, complete the initial deployment, and then change the firewall mode within the ASA CLI.
Because changing the firewall mode erases the configuration, you must then redeploy the configuration from the FXOS chassis to regain the bootstrap configuration. The ASA then remains in transparent mode with a working bootstrap configuration.
Procedure
Step 1
Connect to the ASA console according to
Connect to the Console of the Application or Decorator, on page
147 . For a cluster, connect to the primary unit. For a failover pair, connect to the active unit.
Step 2
Enter configuration mode:
enable configure terminal
By default, the enable password is blank.
148
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Change an Interface on a Firepower Threat Defense Logical Device
Step 3
Set the firewall mode to transparent:
firewall transparent
Step 4
Save the configuration:
write memory
For a cluster or failover pair, this configuration is replicated to secondary units: asa(config)# firewall transparent asa(config)# write memory
Building configuration...
Cryptochecksum: 9f831dfb 60dffa8c 1d939884 74735b69
3791 bytes copied in 0.160 secs
[OK] asa(config)#
Beginning configuration replication to Slave unit-1-2
End Configuration Replication to slave.
asa(config)#
Step 5
On the Firepower Chassis Manager
Logical Devices
page, click the
Edit
icon to edit the ASA.
The
Provisioning
page appears.
Step 6
Click the device icon to edit the bootstrap configuration. Change any value in your configuration, and click
OK
.
You must change the value of at least one field. Cisco recommends changing the
Password
to a new password because this setting is not important.
You see a warning about changing the bootstrap configuration; click
Yes
.
Step 7
Click
Save
to redeploy the configuration to the ASA.For an inter-chassis cluster or for a failover pair, repeat steps 5 through 7 to redeploy the bootstrap configuration on each chassis.
Wait several minutes for the chassis/security modules to reload, and for the ASA to to become operational again. The ASA now has an operational bootstrap configuration, but remains in transparent mode.
Change an Interface on a Firepower Threat Defense Logical Device
You can allocate or unallocate an interface, or replace a management interface on a Firepower Threat Defense logical device. You can then sync the interface configuration in the Firepower Management Center.
Before You Begin
• Configure your interfaces, and add any EtherChannels according to
Edit Interface Properties, on page
116 and
Create a Port Channel, on page 117
.
• You can edit the membership of an allocated EtherChannel without affecting the logical device or requiring a sync on the Firepower Management Center.
• If you want to add an already-allocated interface to an EtherChannel (for example, all interfaces are allocated by default to a cluster), you need to unallocate the interface from the logical device first, then
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
149
Logical Devices
Change an Interface on an ASA Logical Device
add the interface to the EtherChannel. For a new EtherChannel, you can then allocate the EtherChannel to the device.
• If you want to replace the management or firepower eventing interface with a management EtherChannel, then you need to create the EtherChannel with at least 1 unallocated data member interface, and then replace the current management interface with the EtherChannel. After the Firepower Threat Defense device reboots (management interface changes cause a reboot), and you sync the configuration in the
Firepower Management Center, you can add the (now unallocated) management interface to the
EtherChannel as well.
• For clustering or High Availability, make sure you add or remove the interface on all units before you sync the configuration in the Firepower Management Center. Note that new interfaces are added in an administratively down state, so they do not affect interface monitoring.
Procedure
Step 1
In the Firepower Chassis Manager, choose
Logical Devices
.
Step 2
Click the
Edit
icon at the top right to edit the logical device.
Step 3
Unallocate a data interface by de-selecting the interface in the
Data Ports
area.
Step 4
Allocate a new data interface by selecting the interface in the
Data Ports
area.
Step 5
Replace the management or eventing interface:
For these types of interfaces, the device reboots after you save your changes.
a) Click the device icon in the center of the page.
b) On the
General/Cluster Information
tab, choose the new
Management Interface
from the drop-down list.
c) On the
Settings
tab, choose the new
Eventing Interface
from the drop-down list.
d) Click
OK
.
If you change the IP address of the Management interface, then you must also change the IP address for the device in the Firepower Management Center: go to
Devices
>
Device Management
>
Device/Cluster
. In the
Management
area, set the IP address to match the bootstrap configuration address.
Step 6
Click
Save
.
Step 7
Log into the Firepower Management Center.
Step 8
Select
Devices
>
Device Management
and click the edit icon ( ) for your Firepower Threat Defense device.
The
Interfaces
tab is selected by default.
Step 9
Click the
Sync Interfaces from device
button on the top left of the
Interfaces
tab.
Step 10
Click
Save
.
You can now click
Deploy
and deploy the policy to assigned devices. The changes are not active until you deploy them.
Change an Interface on an ASA Logical Device
You can allocate, unallocate, or replace a management interface on an ASA logical device. ASDM discovers the new interfaces automatically.
150
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Logical Devices
Change an Interface on an ASA Logical Device
Before You Begin
• Configure your interfaces and add any EtherChannels according to
Edit Interface Properties, on page
116 and
Create a Port Channel, on page 117
.
• You can edit the membership of an allocated EtherChannel without affecting the logical device.
• If you want to add an already-allocated interface to an EtherChannel (for example, all interfaces are allocated by default to a cluster), you need to unallocate the interface from the logical device first, then add the interface to the EtherChannel. For a new EtherChannel, you can then allocate the EtherChannel to the device.
• If you want to replace the management interface with a management EtherChannel, then you need to create the EtherChannel with at least 1 unallocated data member interface, and then replace the current management interface with the EtherChannel. After the ASA reloads (management interface changes cause a reload), you can add the (now unallocated) management interface to the EtherChannel as well.
• For clustering or failover, new interfaces are added in an administratively down state, so they do not affect interface monitoring.
Procedure
Step 1
In the Firepower Chassis Manager, choose
Logical Devices
.
Step 2
Click the
Edit
icon at the top right to edit the logical device.
Step 3
Unallocate a data interface by de-selecting the interface in the
Data Ports
area.
Step 4
Allocate a new data interface by selecting the interface in the
Data Ports
area.
Step 5
Replace the management interface:
For this type of interface, the device reloads after you save your changes.
a) Click the device icon in the center of the page.
b) On the
General/Cluster Information
tab, choose the new
Management Interface
from the drop-down list.
c) Click
OK
.
Step 6
Click
Save
.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
151
Change an Interface on an ASA Logical Device
Logical Devices
152
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
11
Security Module/Engine Management
•
About FXOS Security Modules/Security Engine, page 153
•
Decommissioning/Recommissioning a Security Module, page 154
•
Acknowledging a Security Module/Engine, page 155
•
Resetting a Security Module/Engine, page 155
•
Reinitializing a Security Module/Engine, page 156
•
Powering On/Off a Security Module/Engine, page 156
About FXOS Security Modules/Security Engine
From the Security Modules/Security Engine page of the Firepower Chassis Manager, you can view the status of and can perform the following functions on a security module/engine:
• Decommission/Recommission (security modules only) — Decommissioning a security module places the security module into maintenance mode. You can also decommission and then recommission a security module in order to correct certain fault states. See
Decommissioning/Recommissioning a Security
.
• Acknowledge — Brings newly installed security modules online. See
.
•
Power Cycle
—
Restarts the security module/engine. See
Resetting a Security Module/Engine, on page
155 .
•
Reinitialize
—
Reformats the security module/engine hard disk, removing all deployed applications and configurations from the security module/engine, and then restarts the system. After reinitialization has completed, if a logical device is configured for the security module/engine, the Firepower eXtensible
Operating System will reinstall the application software, redeploy the logical device, and auto start the application. See
Reinitializing a Security Module/Engine, on page 156
.
Warning
All application data on the security module/engine is deleted during reinitialization.
Please back up all application data before reinitializing a security module/engine.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
153
Security Module/Engine Management
Decommissioning/Recommissioning a Security Module
• Power off/on — Toggles the power state for the security module/engine. See
.
The Security Modules/Security Engine page provides the following information:
• Hardware State — Shows the state of the security module/engine hardware.
◦ Up — The security module/engine has powered up successfully and is not showing any hardware faults.
◦
Booting Up
—
The security module/engine is in the process of powering up.
◦
Down
—
The security module/engine is not powered on or a hardware fault is preventing the security module/engine from starting successfully.
◦ Unassociated — The security module/engine does not have a logical device associated with it.
◦ Mismatch — The security module has been decommissioned or a new security module was installed into the slot. Use the Recommission or Acknowledge function to return the security module to a functioning state.
• Service State — Shows the state of the software on the security module/engine:
◦ Not-available — The security module has been removed from the chassis slot. Reinstall the security module to return it to its normal operational state.
◦ Offline — The security module/engine is installed but has been decommissioned, has been powered off, or is still in the process of powering up.
◦
Online
—
The security module/engine is installed and is in normal operation mode.
◦
Not Responding
—
The security module/engine is unresponsive.
◦ Fault — The security module/engine is in a fault state. Review the system fault listing for more information about what might be causing the fault state.
◦
Token Mismatch
—
Indicates that a security module other than the one previously configured has been installed into the chassis slot. This could also be caused by a software installation error. Use the Reinitialize function to return the security module to a functioning state.
• Power — Shows the power status of the security module/engine:
◦ On — Use the Power off/on function to toggle the power status for the security module/engine.
◦
Off
—
Use the Power off/on function to toggle the power status for the security module/engine.
• Application — Shows the logical device type that is installed on the security module/engine.
Decommissioning/Recommissioning a Security Module
When you decommission a security module, the security module object is deleted from the configuration and the security module becomes unmanaged. Any logical devices or software running on the security module will become inactive.
You can decommission a security module if you want to temporarily discontinue use of the security module.
Also, if restarting a security module cannot correct an error condition, you can try decommissioning and then
154
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Security Module/Engine Management
Acknowledging a Security Module/Engine
recommissioning the security module to see if you can correct the error condition without having to reinitalize the security module.
Procedure
Step 1
Choose
Security Modules
to open the Security Modules page.
Step 2
To decommission a security module, click
Decommission
for that security module.
To recommission a security module, click
Recommission
for that security module.
Step 3
Click
Yes
to verify that you want to decommission or recommission the specified security module.
Acknowledging a Security Module/Engine
When a new security module is installed into the chassis, you must acknowledge the security module before you can begin using it.
If the security module is showing a status of "mismatch" or "token mismatch", this is an indication that the security module installed in the slot has data on it that does not match what was previously installed in the slot. If the security module has existing data on it and you are sure you want to use it in the new slot (in other words, the security module wasn't inadvertently installed into the wrong slot), you must reinitialize the security module before you can deploy a logical device to it.
Procedure
Step 1
Choose
Security Modules/Security Engine
to open the Security Modules/Security Engine page.
Step 2
Click
Acknowledge
for the security module/engine that you want to acknowledge.
Step 3
Click
Yes
to verify that you want to acknowledge the specified security module/engine.
Resetting a Security Module/Engine
Procedure
Step 1
Choose
Security Modules/Security Engine
to open the Security Modules/Security Engine page.
Step 2
Click
Power Cycle
for the security module/engine that you want to reset.
Step 3
Do one of the following:
• Click
Safe Power Cycle
to have the system wait for up to five minutes for the application running on the security module/engine to shut down before the system resets the specified security module/engine.
• Click
Power Cycle Immediately
to have the system reset the specified security module/engine immediately.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
155
Security Module/Engine Management
Reinitializing a Security Module/Engine
Reinitializing a Security Module/Engine
When a security module/engine is reinitialized, the security module/engine hard disk is formatted and all installed application instances and configurations are removed. After reinitialization has completed, if a logical device is configured for the security module/engine, the Firepower eXtensible Operating System will reinstall the application software, redeploy the logical device, and auto start the application.
Warning
All application data on the security module/engine is deleted during reinitialization. Please back up all application data before reinitializing a security module/engine.
Procedure
Step 1
Choose
Security Modules/Security Engine
to open the Security Modules/Security Engine page.
Step 2
Click
Reinitialize
for the security module/engine that you want to reinitialize.
Step 3
Click
Yes
to verify that you want to reinitialize the specified security module/engine.
The security module/engine is restarted and all data on the security module is deleted. This process can take several minutes.
Powering On/Off a Security Module/Engine
Procedure
Step 1
Choose
Security Modules/Security Engine
to open the Security Modules/Security Engine page.
Step 2
To power off a security module/engine: a) Click
Power off
for that security module/engine.
b) Do one of the following:
• Click
Safe Power Off
to have the system wait for up to five minutes for the application running on the security module/engine to shut down before the system powers down the specified security module/engine.
• Click
Power Off Immediately
to have the system power down the specified security module/engine immediately.
Step 3
To power on a security module/engine: a) Click
Power on
for that security module/engine.
b) Click
Yes
to verify that you want to power on the specified security module/engine.
156
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Security Module/Engine Management
Powering On/Off a Security Module/Engine
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
157
Powering On/Off a Security Module/Engine
Security Module/Engine Management
158
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
12
Configuration Import/Export
•
About Configuration Import/Export, page 159
•
Exporting a Configuration File, page 160
•
Scheduling Automatic Configuration Export, page 161
•
Setting a Configuration Export Reminder, page 162
•
Importing a Configuration File, page 162
About Configuration Import/Export
You can use the configuration export feature to export an XML file containing logical device and platform configuration settings for your FXOS chassis to a remote server or your local computer. You can later import that configuration file to quickly apply the configuration settings to your FXOS chassis to return to a known good configuration or to recover from a system failure.
Guidelines and Restrictions
• Do not modify the contents of the configuration file. If a configuration file is modified, configuration import using that file might fail.
• Application-specific configuration settings are not contained in the configuration file. You must use the configuration backup tools provided by the application to manage application-specific settings and configurations.
• When you import a configuration to the FXOS chassis, all existing configuration on the FXOS chassis
(including any logical devices) will be deleted and completely replaced by the configuration contained in the import file.
• We recommend that you only import a configuration file to the same FXOS chassis from which the configuration was exported.
• The platform software version of the FXOS chassis to which you are importing should be the same version as when the export was taken. If not, the import operation is not guaranteed to be successful.
We recommend that you export a backup configuration whenever the FXOS chassis is upgraded or downgraded.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
159
Configuration Import/Export
Exporting a Configuration File
• The FXOS chassis to which you are importing must have the same Network Modules installed in the same slots as when the export was taken.
• The FXOS chassis to which you are importing must have the correct software application images installed for any logical devices defined in the export file that your are importing.
• If the configuration file being imported contains a logical device whose application has an End-User
License Agreement (EULA), the EULA for that application must be accepted on the FXOS chassis before importing the configuration or the operation will fail.
• To avoid overwriting existing backup files, please be sure to change the filename in the backup operation or copy the existing file to another location.
Exporting a Configuration File
Use the configuration export feature to export an XML file containing logical device and platform configuration settings for your FXOS chassis to a remote server or your local computer.
Please review the
About Configuration Import/Export
for important information about using the configuration export feature.
Procedure
Step 1
Choose
System
>
Configuration
>
Export
.
Step 2
To export a configuration file to your local computer, click
Export Locally
.
The configuration file is created and, depending on your browser, the file might be automatically downloaded to your default download location or you might be prompted to save the file.
Step 3
To export the configuration file to a previously configured remote server, click
Export
for the Remote
Configuration you want to use.
The configuration file is created and exported to the specified location.
Step 4
To export the configuration file to a new remote server: a) Under On-Demand Export, click
Add On-Demand Configuration
.
b) Choose the protocol to use when communicating with the remote server. This can be one of the following:
FTP, TFTP, SCP, or SFTP.
c) Enter the hostname or IP address of the location where the backup file should be stored. This can be a server, storage array, local drive, or any read/write media that the FXOS chassis can access through the network.
If you use a hostname rather than an IP address, you must configure a DNS server.
d) If you are using a non-default port, enter the port number in the
Port
field.
e) Enter the username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP.
f) Enter the password for the remote server username. This field does not apply if the protocol is TFTP.
g) In the
Location
field, enter the full path to where you want the configuration file exported including the filename. If you omit the filename, the export procedure assigns a name to the file.
h) Click
OK
.
The Remote Configuration is added to the On-Demand Export table.
i) Click
Export
for the Remote Configuration you want to use.
160
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Configuration Import/Export
Scheduling Automatic Configuration Export
The configuration file is created and exported to the specified location.
Scheduling Automatic Configuration Export
Use the scheduled export feature to automatically export an XML file containing logical device and platform configuration settings for your FXOS chassis to a remote server or your local computer. You can schedule the exports to be run daily, weekly, or every two weeks. The configuration export will be executed according to the schedule based on the when the scheduled export feature is enabled. So, for example, if you enable weekly scheduled export on a Wednesday at 10:00pm, the system will trigger a new export every Wednesday at 10:00pm.
Please review the
About Configuration Import/Export
for important information about using the configuration export feature.
Procedure
Step 1
Choose
System
>
Configuration
>
Export
.
Step 2
Click
Schedule Export
.
You see the
Configure Scheduled Export
dialog box.
Step 3
Choose the protocol to use when communicating with the remote server. This can be one of the following:
FTP, TFTP, SCP, or SFTP.
Step 4
To enable the scheduled export, check the
Enable
check box.
Note
You can enable or disable the schedule export at a later time using this check box; however, you will need to specify the password again when enabling or disabling the scheduled export.
Step 5
Enter the hostname or IP address of the location where the backup file should be stored. This can be a server, storage array, local drive, or any read/write media that the FXOS chassis can access through the network.
If you use a hostname rather than an IP address, you must configure a DNS server.
Step 6
If you are using a non-default port, enter the port number in the
Port
field.
Step 7
Enter the username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP.
Step 8
Enter the password for the remote server username. This field does not apply if the protocol is TFTP.
Step 9
In the
Location
field, enter the full path to where you want the configuration file exported including the filename. If you omit the filename, the export procedure assigns a name to the file.
Step 10
Choose the schedule on which you would like to have the configuration automatically exported. This can be one of the following: Daily, Weekly, or BiWeekly.
Step 11
Click
OK
.
The scheduled export is created. If you enabled the scheduled export, the system will automatically export a configuration file to the specified location according to the schedule that you selected.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
161
Configuration Import/Export
Setting a Configuration Export Reminder
Setting a Configuration Export Reminder
Use the Export Reminder feature to have the system generate a fault when a configuration export hasn't been executed in a certain number of days.
Procedure
Step 1
Choose
System
>
Configuration
>
Export
.
Step 2
To enable the configuration export reminder, check the check box under
Reminder to trigger an export
.
Step 3
Enter the number of days, between 1 and 365, that the system should wait between configuration exports before generating a reminder fault.
Step 4
Click
Save Reminder
.
Importing a Configuration File
You can use the configuration import feature to apply configuration settings that were previously exported from your FXOS chassis. This feature allows you to return to a known good configuration or to recover from a system failure. Please review the
About Configuration Import/Export
for important information about using the configuration import feature.
Procedure
Step 1
Choose
System
>
Configuration
>
Import
.
Step 2
To import from a local configuration file: a) Click
Choose File
to navigate to and select the configuration file that you want to import.
b) Click
Import
.
A confirmation dialog box opens asking you to confirm that you want to proceed and warning you that the chassis might need to restart.
c) Click
Yes
to confirm that you want to import the specified configuration file.
The existing configuration is deleted and the configuration specified in the import file is applied to the
FXOS chassis. If there is a breakout port configuration change during the import, the FXOS chassis will need to restart.
Step 3
To import the configuration file from a previously configured remote server: a) In the Remote Import table, click
Import
for the Remote Configuration you want to use.
A confirmation dialog box opens asking you to confirm that you want to proceed and warning you that the chassis might need to restart.
b) Click
Yes
to confirm that you want to import the specified configuration file.
The existing configuration is deleted and the configuration specified in the import file is applied to the
FXOS chassis. If there is a breakout port configuration change during the import, the FXOS chassis will need to restart.
Step 4
To import from a configuration file on a new remote server:
162
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Configuration Import/Export
Importing a Configuration File
a) Under Remote Import, click
Add Remote Configuration
.
b) Choose the protocol to use when communicating with the remote server. This can be one of the following:
FTP, TFTP, SCP, or SFTP.
c) If you are using a non-default port, enter the port number in the
Port
field.
d) Enter the hostname or IP address of the location where the backup file is stored. This can be a server, storage array, local drive, or any read/write media that the FXOS chassis can access through the network.
If you use a hostname rather than an IP address, you must configure a DNS server.
e) Enter the username the system should use to log in to the remote server. This field does not apply if the protocol is TFTP.
f) Enter the password for the remote server username. This field does not apply if the protocol is TFTP.
g) In the
File Path
field, enter the full path to the configuration file including the filename.
h) Click
Save
.
The Remote Configuration is added to the Remote Import table.
i) Click
Import
for the Remote Configuration you want to use.
A confirmation dialog box opens asking you to confirm that you want to proceed and warning you that the chassis might need to restart.
j) Click
Yes
to confirm that you want to import the specified configuration file.
The existing configuration is deleted and the configuration specified in the import file is applied to the
FXOS chassis. If there is a breakout port configuration change during the import, the FXOS chassis will need to restart.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
163
Importing a Configuration File
Configuration Import/Export
164
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
C H A P T E R
13
Packet Capture
•
About Packet Capture, page 165
•
Creating or Editing a Packet Capture Session, page 166
•
Configuring Filters for Packet Capture, page 168
•
Starting and Stopping a Packet Capture Session, page 169
•
Downloading a Packet Capture File, page 169
About Packet Capture
The Packet Capture tool is a valuable asset for use in debugging connectivity and configuration issues and for understanding traffic flows through your FXOS chassis. You can use the Packet Capture tool to log traffic that is going through specific customer-facing ports or application ports on your FXOS chassis.
You can create multiple packet capture sessions and each session can capture traffic on multiple ports. For each port included in a packet capture session, a separate packet capture (PCAP) file will be created.
Backplane Port Mappings
The FXOS chassis uses the following mappings for internal backplane ports:
Security Module
Security Module 1/Security Engine
Port Mapping
Ethernet1/9
Description
Internal-Data0/0
Security Module 1/Security Engine
Security Module 2
Ethernet1/10
Ethernet1/11
Internal-Data0/1
Internal-Data0/0
Security Module 2
Security Module 3
Security Module 3
Ethernet1/12
Ethernet1/13
Ethernet1/14
Internal-Data0/1
Internal-Data0/0
Internal-Data0/1
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
165
Packet Capture
Creating or Editing a Packet Capture Session
Guidelines and Limitations
The Packet Capture tool has the following limitations:
• Can capture only up to 100 Mbps.
• Packet capture sessions can be created even when there is not enough storage space available to run the packet capture session. You should verify that you have enough storage space available before you start a packet capture session.
• Does not support multiple active packet capturing sessions.
• There is no option to filter based on source or destination IPv6 address.
• Captures only at Ingress stage of internal switch.
• Filters are not effective on packets which cannot be understood by internal switch (for example Security
Group Tag and Network Service Header packets).
• Abstractions are not supported (for example, port channels and service chain).
Note
Although capturing traffic on port channels is not supported, you can include the individual member ports that make up a port channel in a packet capture session and the packet capture tool will create separate packet capture files for each of those member ports.
• You cannot copy or export a PCAP file while the capture session is still active.
• When you delete a packet capture session, all packet capture files associated with that session are also deleted.
Creating or Editing a Packet Capture Session
Procedure
Step 1
Choose
Tools
>
Packet Capture
.
The
Capture Session
tab displays a list of currently configured packet capture sessions. If no packet capture sessions are currently configured, a message stating so is displayed instead.
Step 2
Do one of the following:
• To create a packet capture session, click the
Capture Session
button.
• To edit an existing packet capture session, click the
Edit
button for that session.
You see the
Configure Packet Capture Session
window. The left side of the
Configure Packet Capture
Session
window allows you to select a specific logical device configured on your FXOS chassis and then shows a representation of that logical device. This representation is used to select the interfaces on which you would like to capture packets. The right side of the
Configure Packet Capture Session
window contains fields for defining the packet capture session.
166
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Packet Capture
Creating or Editing a Packet Capture Session
Step 3
Enter a name for the packet capture session in the
Session Name
field.
Step 4
Specify the buffer size to use for this packet capture session by selecting one of the pre-defined values from the
Buffer Size
list, or by selecting
Custom in MB
and then entering the desired buffer size. The specified buffer size must be between 256 and 2048 MB.
Step 5
Specify whether you want to overwrite existing PCAP files or append data to the PCAP files when this packet capture session is executed.
Step 6
On the left side of the
Configure Packet Capture Session
window, click the name of the logical device for which you would like to capture packets.
You see a representation of the selected logical device including all interfaces assigned to the device.
Step 7
To capture traffic on any of the customer-facing ports assigned to the logical device, click the desired interface to select it.
Step 8
To capture traffic from the logical device going out over the backplane ports: a) Click the box representing the logical device.
The
Capture On
,
Application Port
, and
Application Capture Direction
fields are made available on the right side of the
Configure Packet Capture Session
window.
b) Select the backplane port you wish to capture traffic on or select
All Backplane Ports
from the
Capture
On
drop-down list.
Step 9
To capture traffic between the logical device and a specific interface: a) Click the box representing the logical device.
The
Capture On
,
Application Port
, and
Application Capture Direction
fields are made available on the right side of the
Configure Packet Capture Session
window.
b) Make sure the logical device (for example, asa) is selected in the
Capture On
drop-down list.
c) Select the interface that you would like to capture traffic coming from or going to in the
Application Port
drop-down list.
d) To capture only the traffic going from the logical device toward the specified interface, click the
Egress
Packets
option next to
Application Capture Direction
.
e) To capture traffic coming from or going to the specified interface, click the
All Packets
option next to
Application Capture Direction
.
Step 10
To filter the traffic being captured: a) Click the
Apply Filter
option for the
Capture Filter
field.
You are given a set of fields for configuring the filter.
b) If you need to create the filter, click
Create Filter
.
You see the
Create Packet Filter
dialog box. For more information, see
Configuring Filters for Packet
.
c) Select the filter you want to use from the
Apply
drop-down list.
d) Select the interface to which you want to apply the filter from the
To
drop-down list.
e) To apply additional filters, click
Apply Another Filter
and then repeat the steps above to apply the additional filter.
Step 11
Do one of the following:
• To save this packet capture session and run it now, click the
Save and Run
button. This option is only available if no other packet capture sessions are currently running.
• To save this packet capture session so that it can be ran at a later time, click the
Save
button.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
167
Packet Capture
Configuring Filters for Packet Capture
You see the
Capture Session
tab with your session listed along with any other sessions that have been created.
If you selected
Save and Run
, your packet capture session will be capturing packets. You will need to stop capturing before you can download the PCAP files from your session.
Configuring Filters for Packet Capture
You can create filters to limit the traffic that is included in a packet capture session. You can select which interfaces should use a specific filter while creating a packet capture session.
Note
If you modify or delete a filter that is applied to a packet capture session that is currently running, the changes will not take affect until you disable that session and then reenable it.
Procedure
Step 1
Choose
Tools
>
Packet Capture
.
The
Capture Session
tab displays a list of currently configured packet capture sessions. If no packet capture sessions are currently configured, a message stating so is displayed instead.
Step 2
Do one of the following:
• To create a filter, click the
Add Filter
button.
• To edit an existing filter, click the
Edit
button for that fitler.
You see the
Create or Edit Packet Filter
dialog box.
Step 3
Enter a name for the packet capture filter in the
Filter Name
field.
Step 4
To filter on a specific protocol, select it from the
Protocol
list, or select
Custom
and then enter the desired protocol. The custom protocol must be an IANA defined protocol in decimal format (0-255).
Step 5
To filter on a specific EtherType, select it from the
EtherType
list, or select
Custom
and then enter the desired
EtherType. The custom EhterType must be an IANA defined EtherType in decimal format (for example, IPv4
= 2048, IPv6 = 34525, ARP = 2054, and SGT = 35081).
Step 6
To filter traffic based on an Inner VLAN (VLAN ID while ingressing the port) or Outer VLAN (VLAN ID added by the FXOS chassis), enter the VLAN ID in the specified field.
Step 7
To filter traffic from a specific source or destination, enter the IP address and port or enter the MAC address in the specified source or destination fields.
Step 8
Click
Save
to save the filter,
You see the
Filter List
tab with your filter listed along with any other filters that have been created.
168
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Packet Capture
Starting and Stopping a Packet Capture Session
Starting and Stopping a Packet Capture Session
Procedure
Step 1
Choose
Tools
>
Packet Capture
.
The
Capture Session
tab displays a list of currently configured packet capture sessions. If no packet capture sessions are currently configured, a message stating so is displayed instead.
Step 2
To start a packet capture session, click the
Enable Session
button for that session and then click
Yes
to confirm.
Note
You cannot start a packet capture session while another session is running.
The PCAP files for the interfaces included in the session will start collecting traffic. If the session is configured to overwrite session data, the existing PCAP data will be erased. If not, data will be appended to the existing file (if any).
While the packet capture session is running, the file size for the individual PCAP files will increase as traffic is captured. Once the Buffer Size limit is reached, the system will start dropping packets and you will see the
Drop Count field increase.
Step 3
To stop a packet capture session, click the
Disable Session
button for that session and then click
Yes
to confirm.
After the session has been disabled, you can then download the PCAP files (see
).
Downloading a Packet Capture File
You can download the Packet Capture (PCAP) files from a session to your local computer so that they can be analyzed using a network packet analyzer.
Procedure
Step 1
Choose
Tools
>
Packet Capture
.
The
Capture Session
tab displays a list of currently configured packet capture sessions. If no packet capture sessions are currently configured, a message stating so is displayed instead.
Step 2
To download the PCAP file for a specific interface from a packet capture session, click the
Download
button that corresponds to that interface.
Note
You cannot download a PCAP file while a packet capture session is running.
Depending on your browser, the specified PCAP file is either automatically downloaded to your default download location or you are prompted to save the file.
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
169
Downloading a Packet Capture File
Packet Capture
170
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
I N D E X
A
AAA
101, 102, 104, 105, 106, 107, 108
LDAP providers
RADIUS providers
TACACS+ providers
accessing the command line interface
accounts
locally authenticated
acknowledging security modules
asa
connecting to
creating a cluster
creating a clustered
creating a standalone asa logical device
deleting a logical device
exiting from connection
updating image version
asa images
about
downloading from Cisco.com
uploading to the Firepower security appliance
authentication
default
authNoPriv
authPriv
B
banner
pre-login
breakout cables
configuring
breakout ports
C
call home
configure http proxy
certificate
about
chassis
initial configuration
monitoring status
chassis manager
user interface overview
Cisco Secure Package
about
downloading from Cisco.com
uploading to the Firepower security appliance
cli, See
clustering
cluster control link
redundancy
size
device-local EtherChannels, configuring on switch
management
network
member requirements
software requirements
spanning-tree portfast
upgrading software
clusters
about
creating
defaults when creating
command line interface
accessing
communication services
HTTPS
SNMP
community, SNMP
configuration import/export
guidelines
restrictions
configuring
HTTPS
connecting to a logical device
corrupted file system
recovering
creating packet capture session
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
IN-1
Index
CSP, See
D
date
setting manually
viewing
date and time
configuring
decommissioning security modules
DNS
downloading packet capture file
E
enabling
SNMP
exiting from logical device connection
export configuration
F
Firepower chassis
See also
initial configuration
See also
Firepower Chassis Manager
logging in or out
user interface overview
Firepower eXtensible OS
upgrading the platform bundle
Firepower platform bundle
about
downloading from Cisco.com
upgrading
uploading to the Firepower security appliance
verifying integrity
Firepower security appliance
overview
Firepower Threat Defense, See
firmware
upgrading
fpga
upgrading
ftd, See
FXOS chassis
monitoring status
powering off
rebooting
IN-2
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
H
high-level task list
history, passwords
http proxy
configuring
HTTPS
8, 90, 91, 92, 94, 95, 96, 97, 99
certificate request
changing port
configuring
creating key ring
disabling
importing certificate
logging in or out
regenerating key ring
trusted point
I
image version
updating
images
downloading from Cisco.com
managing
upgrading the Firepower eXtensible Operating System platform bundle
uploading to the Firepower security appliance
verifying integrity
import configuration
informs
about
initial configuration
interfaces
administrative state
configuring
properties
K
key ring
about
certificate request
creating
deleting
importing certificate
regenerating
trusted point
Index
L
LDAP
LDAP providers
creating
deleting
license
registering
license authority
locally authenticated users
password profile
logging in or out
logical devices
36, 122, 123, 125, 132, 135, 138, 147, 148
connecting to
creating a cluster
creating a standalone
deleting
exiting from connection
understanding
updating image version
M
management IP address
changing
monitoring chassis status
N
noAuthNoPriv
NTP
adding
configuring
deleting
P
packet capture
creating packet capture session
downloading PCAP file
filter
starting a packet capture session
stopping a packet capture session
password profile
about
passwords
change interval
guidelines
history count
strength check
PCAP, See
PCAP file
downloading
PKI
platform bundle
about
downloading from Cisco.com
upgrading
uploading to the Firepower security appliance
verifying integrity
port channels
configuring
powering off FXOS chassis
powering on/off security modules
pre-login banner
creating
deleting
modifying
profiles
password
R
RADIUS
RADIUS providers
creating
deleting
rebooting
registering a license
reinitializing security modules
resetting security modules
rommon
upgrading
RSA
S
security modules
acknowledging
decommissioning
powering off
powering on
reinitializing
resetting
smart call home
configure http proxy
SNMP
about
community
enabling
notifications
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
IN-3
Index
SNMP
(continued)
privileges
security levels
support
traps
creating
deleting
users
creating
deleting
Version 3 security features
SNMPv3
security features
software failure
recovering
SSH
configuring
syslog
configuring local destinations
configuring local sources
configuring remote destinations
system
initial configuration
system recovery
T
TACACS+
TACACS+ providers
creating
deleting
task flow
Telnet
configuring
threat defense
connecting to
creating a cluster
creating a clustered
creating a standalone threat defense logical device
threat defense
(continued)
deleting a logical device
exiting from connection
time
setting manually
viewing
time zone
setting
traps
about
creating
deleting
trusted points
about
creating
deleting
U
upgrading the firmware
user accounts
password profile
user interface
overview
users
19, 20, 21, 24, 25, 29, 30, 88, 89
activating
creating
deactivating
default authentication
deleting
locally authenticated
managing
naming guidelines
password guidelines
roles
settings
SNMP
IN-4
Cisco FXOS Firepower Chassis Manager Configuration Guide, 2.0(1)
Download
Advertisement
Key features
Modular chassis-based security system
Graphical user interface
FXOS CLI
FXOS REST API
Frequently asked questions
To log in, open a supported browser and enter the URL https://<chassis_mgmt_ip_address>, where <chassis_mgmt_ip_address> is the IP address or hostname of the FXOS chassis. Then, enter your username and password and click Login.
First, configure the FXOS chassis hardware. Then, complete the initial configuration, which includes setting the date and time, configuring a DNS server, registering your product license, configuring users, performing software updates, configuring platform settings, configuring interfaces, and creating logical devices.
The Overview page in the Firepower Chassis Manager provides a visual representation of the chassis, showing the installed components and their status. You can also view detailed status information about faults, interfaces, devices, licenses, and inventory.