Delayed Egress Rim Exit Device (V40xEE)
The V40xEE, designed for primary and secondary exits, provides a secure 15-second delay and a 100dB alarm when someone attempts to exit. This 15-second delay allows management time to respond before someone exits and the alarm deters the exit from occurring. Per life safety requirements, the V40xEE must be provided with a fire alarm input, thus providing a system override during a fire emergency. The V40xEE provides security while meeting all life safety concerns, offering an exceptional value.
Power Supply Included as standard feature
V40xEE
(Shown with mortise cylinder - sold separately)
V40xEEx711xBLK
(Shown with mortise cylinder - sold separately)
Wide Stile shown, for Narrow Stile, specify NS Option
(for use on 36” and 48” doors with 2” stiles).
Shown with factory installed mortise cylinder
V40xEEx711
(Shown with mortise cylinder - sold separately)
Benefits
• Priced to be the best value for
durable and attractive delayed
egress panic hardware
• Reduces employee and customer
theft
• Fast and easy installation
Features
• Powered by a 24VDC filtered and
regulated power supply
• Power supply delivers a constant
24VDC of filtered and regulated
voltage at a rated load of 1A
• Stainless steel, 3/4" deadlocking
Pullman-type latch bolt
• Non-handed, field sizeable
• 100dB alarm
• 1/8 turn cylinder dogging
• Heavy-duty ribbed aluminum rail
extrusion
• Delayed arming allows arming
after door closes
• Secure installation prevents
mistakes, enhances security and
reduces maintenance
• Durable design provides years of
trouble-free protection, saving on
replacement costs
• Accommodates all types of mortise
cylinders with a standard Yale cam
• Patented mounting plate and
strike locator system provide
perfect alignment with door and
frame
• Single mortise cylinder provides
arming and dogging - can be
factory installed
• State-of-the-art electronics offer
reliable security and instantaneous
alarm
• Visual and audible arming
indicators
• 9V battery provides alarm function
only in case of power failure
• Fits almost any door in any décor
• Controls foot traffic, deters unauthorized exits, prevents loss and meets building code requirements
• Armed and disarmed field
selectable status indicator
• Sturdy angled end-cap
• Remote signal output and remote
bypass input standard
• Alarm triggered by latch bolt
movement
• Fire alarm input can be connected
at power supply
• Includes delayed egress panic bar,
24VDC filtered and regulated
power supply, door sign and
3’ conduit loop
• FC3 - Flexible 3’ Flex Conduit Kit, mounts to device end cap
Electrical Options
• 30 - 30 second delayed egress
available (must have letter from
AHJ)
• EE05 Options Package - Nonextended bypass, alarm sounds if door left open / silent arming / reset alarm with access control, or reset alarm with key only
• AL18 - Surface Armored Loop
(Door/Frame mounted)
• 1 second arming (15 second arming
Std.)
• Silent arming (3 chirps when arming Std.)
• SI- Status Indicators - Armed/
Disarmed
Mechanical Options
• MC65 - Factory Installed Mortise
cylinder
• IC7 - Factory Installed IC Housing
• F - 3-Hour Fire Rated
• H - Hurricane Rated
• CD - Cylinder Dogging (Std.)
• LD - Less Dogging
• 36” Door Width (Std.)
Accessories
• SN1 - Sex Nut Fasteners
• NSK - Narrow Stile Conversion
Kit - Converts V40 to fit narrow stile glass door applications
Dimensions
1 3/4”
8 3/8” 2 3/8”
18 1/8”
24 1/8”
• 48" Door Width
• 99 - Surface Strike (Std.)
• 98 - Semi Mortise Strike
• KS - Key Stop (Key removed only
when armed)
• Available with 628 Base Rail
Extrusion (Std.)
• Available with 711 Base Rail Extrusion
• Optional Cylinder Nut Wrench
P/N: 103779
3 1/4” EXTENDED
2 1/2” DEPRESSED
2 3/8”
32 7/8”
44 7/8”
Add 2” for NS
Riser Diagram
Terminal Block
TERMINAL BLOCK
1 2 3 4 5 6 7 8 9 10 11 12
To Fire Alarm
System
Filtered and Regulated
Power Supply with
Fire Alarm System Loop
24VDC
(Power Supply
Included Standard)
24 VDC
POWER
POWER
FACTORY INSTALLED
Remote Bypass
Bypass Relay Output
Alarm Relay Output
(+)
(-)
COMMON
OPEN
CLOSED
COMMON
OPEN
CLOSED
Listings and Approvals
July 25, 2017
UL Listed Panic Hardware
UL Listed Fire Exit Hardware for 3 hours, maximum 4’x10’ single doors and pairs of 4’x8’ with F90KR keyed removable mullion
UL Listed Controled Exit
Device (FULA)
UL Listed Special Locking
Arrangements (FWAX)
Meets ADA requirements
ANSI/BHMA certified A156.3
• LF - Less Flex Conduit
• FC10 - Flexible 10’ Flex Conduit Kit, mounts to device end cap
• PT5 - Concealed mortise mount power transfer
• EH8 - Five-knuckle energy transfer hinge
• Outside Trim (see Value Series
Trim Options)
• Foreign Language Signs available
Contact Factory
UBC 97, Standard 7-2 and
UL10B/UL10C for positive pressure
Meets NFPA 80 & 101 for Life
Safety
Miami-Dade County, Florida
NOA 15-0415.08
State of Florida Approval
FL9052
California State Fire Marshall
4140-0127:105 and
3725-0127:108
Technical Information
• Door Types - Wood, Hollow
Metal, Fiberglass or Aluminum
• Door Thickness - Fits standard
1-3/4” - 2-1/4”
• Single Door Stile - Fits 3-1/2” minimum stile doors with 99 surface strike (Std.)
• Pairs of Doors Stile - Fits 4” minimum stile doors with 99 surface strike
• Door Stile - Fits 2” narrow stile
doors - specify NS
• Machine and Self-Drilling Screws
(Std.)
• Optional Sex Nuts or Security
Torx Screws available
Detex Limited Warranty
10 Year Mechanical/3 Year Electrical
Limited Manufacturer's Warranty
Detex Corporation
302 Detex Drive
New Braunfels, Texas 78130-3045 USA
PH. (830) 629-2900
(800) 729-3839
FAX (800) 653-3839 http://www.detex.com
USA Sales: [email protected]
International Sales: [email protected]
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement