- Industrial & lab equipment
- Electrical equipment & supplies
- Power generators
- Guardian Technologies
- QT048
- User's manual
Guardian Technologies QT048 User's Manual
Add to My manualsadvertisement
QT048
Standby Power Rating
48 kW 60 Hz
Liquid Cooled Gas Engine Generator Sets
GENERAC 4.2L ENGINE
Naturally Aspirated
Gaseous Fueled
STANDARD EQUIPMENT
• All input connections in one single area
• High coolant temperature shutdown
• Low oil pressure shutdown
• Low coolant level automatic shutdown
• Overspeed automatic shutdown
• Crank timer
• Exercise timer
• Oil drain extension
• Cool flow radiator
• Closed coolant recovery system
• UV/Ozone resistant hoses
• Watertight state of the art electrical connectors
FEATURES
• Innovative design and fully prototype tested
• UL2200 Listed
• Solid state frequency compensated voltage regulator
• Dynamic and static battery charger
• Sound attenuated acoustically designed enclosure
• Quiet test for low noise level exercise
• Acoustically designed engine cooling system
• High flow low noise factory engineered exhaust system
• Mainline circuit breaker
• Radiator drain extension
• Battery charge alternator
• 2 Amp static battery charger
• Battery cables
• Battery rack
• Fan and belt guards
• Isochronous governor
• Flex fuel line
• Hour meter
• State of the art digital control system with R100 digital control panel
• Watertight electrical connectors
• Rodent proof construction
• High efficiency, low distortion Generac designed alternator
• Vibration isolated from mounting base
• Matching Generac transfer switches engineered and tested to work as a system
• All components easily accessible for maintenance
• Electrostatically applied powder paint
APPLICATION
& ENGINEERING DATA
QT048
GENERATOR SPECIFICATIONS
TYPE ...........................................................................................................Synchronous
ROTOR INSULATION ..........................................................................................Class H
STATOR INSULATION .........................................................................................Class H
TOTAL HARMONIC DISTORTION ........................................................................... <5%
TELEPHONE INTERFERENCE FACTOR (TIF) ........................................................<50
ALTERNATOR OUTPUT LEADS 3 PHASE ...........................................................4 wire
BEARINGS .................................................................................................... Sealed Ball
COUPLING .................................................................................................. Flexible Disc
LOAD CAPACITY (STANDBY RATING) ................................................................ 48 kW
EXCITATION SYSTEM ........................................................................................... Direct
ENGINE SPECIFICATIONS
MAKE ................................................................................................................ Generac
MODEL ........................................................................................................................ V6
CYLINDERS ...................................................................................................................6
DISPLACEMENT .................................................................................................4.2 Liter
BORE (inches) ..........................................................................................................3.81
STROKE (inches) ......................................................................................................3.74
COMPRESSION RATIO ...........................................................................................9.3:1
INTAKE AIR SYSTEM ....................................................................... Naturally Aspirated
VALVE SEATS (Int. & Exh.) ........................................... Precision ground and hardened
LIFTER TYPE ........................................................................................ Roller, Hydraulic
NOTE: Generator rating and performance in accordance with
ISO8528-5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.
GOVERNOR SPECIFICATIONS
VOLTAGE REGULATOR
TYPE ................................................................................................................Electronic
FREQUENCY REGULATION ....................................................................... Isochronous
STEADY STATE REGULATION .......................................................................... ± 0.25%
TYPE ................................................................................................................Electronic
SENSING ................................................................................................... Single Phase
REGULATION .......................................................................................................... ± 1%
FEATURES ............................................................................................... V/F Adjustable
Adjustable Voltage and Gain
LED Indicators
ENGINE LUBRICATION SYSTEM
OIL PUMP ................................................................................................................Gear
OIL FILTER ............................................................................. Full flow spin-on cartridge
CRANKCASE CAPACITY ...................................................................................6 Quarts
GENERATOR FEATURES
Revolving field heavy duty generator
Insulation is Class H rated at 150 °C rise
ENGINE COOLING SYSTEM
TYPE ................................................................................................ Pressurized Closed
WATER PUMP FLOW ..................................................................................10.8 gal/min
FAN SPEED .............................................................................................................1050
FAN DIAMETER ............................................................................................... 22 inches
FAN MODE ..............................................................................................................Puller
CONTROL PANEL FEATURES
SEVEN LED INDICATOR LIGHTS ADDITIONAL FUNCTIONS
• System ready
• Low fuel pressure
• Low battery
• Utility sensing
• Delay on utility failure for engine start
• Engine warm-up before transfer
• Low oil pressure • Delay to retransfer to utility
• High coolant temp/low coolant temp • Engine cooldown timer
• Overspeed
• Overcrank
• Exerciser not set
• Hour meter
FUEL SYSTEM
FUEL TYPE ..........................................................................Natural gas, propane vapor
CARBURETOR...............................................................................................Down Draft
SECONDARY FUEL REGULATOR ................................................................... Standard
FUEL SHUT OFF SOLENOID .......................................................................... Standard
OPERATING FUEL PRESSURE ..................................................................5” - 14” H2O
INTERNAL FUNCTIONS:
• 3 position switch (auto, off and manual)
• 2 wire start for any transfer switch
• Communicates with the Generac RTS transfer switch
• Built-in 7 day exerciser
• Selectable engine speed at exercise
• Governor controller is built into the master control board
• Temperature range -40 ° C to 70 °C
ELECTRICAL SYSTEM
BATTERY CHARGE ALTERNATOR .............................................................12V 30 Amp
STATIC BATTERY CHARGER .............................................................................. 2 Amp
RECOMMENDED BATTERY .......................................................... Group 24F, 525CCA
SYSTEM VOLTAGE .............................................................................................12 Volts
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with
BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).
QT048
OPERATING DATA
kW RATING
ENGINE SIZE
GENERATOR OUTPUT VOLTAGE/KW - 60Hz
120/208V, 3-phase, 0.8 pf
120/240V, 3-phase, 0.8 pf
277/480V, 3-phase, 0.8 pf
GENERATOR LOCKED ROTOR KVA
AVAILABLE @ VOLTAGE DIP OF 35%
Single phase or 208 3-phase
480V 3-phase
ENGINE FUEL CONSUMPTION (Natural Gas) (Propane)
Exercise cycle
25% of rated load
50% of rated load
75% of rated load
100% of rated load
ENGINE COOLING
Air flow (inlet air including alternator and combustion air)
System coolant capacity
Heat rejection to coolant
Max. operating air temp. on radiator
Max. ambient temperature
COMBUSTION AIR REQUIREMENTS
Flow at rated power 60 Hz
SOUND EMISSIONS IN DBA
Exercising at 7 meters
Normal operation at 7 meters ft 3 /min.
US gal.
BTU/hr.
°C (°F)
°C (°F) cfm
EXHAUST
Exhaust flow at rated output 60 Hz
Exhaust temp. at muffler outlet
ENGINE PARAMETERS
Rated synchronous RPM
HP at rated KW cfm
°F
60 Hz
60 Hz
POWER ADJUSTMENT FOR AMBIENT CONDITIONS
Temperature Deration
3% for every 10 °C above - °C
1.65% for every 10 °F above - °F
Altitude Deration
1% for every 100 m above - m
3% for every 1000 ft. above - ft.
kW - LP
48
48
48
Natural Gas
(ft 3 /hr.)
88
205
370
516
661
QT048
48
4.2 Liter V6
Amps kW - NG Amps
166 46 160
144
72
46
46
138
69
100
110
(gal/hr.)
0.94
2.23
4.03
5.62
7.20
2,460
3.0
165,000
60 (150)
50 (140)
235
60
65
395
1100
1800
75
25
77
183
600
Propane
CB Size
175
150
80 cu ft/hr
34.4
81
147
204
261
RATING: All three phase units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1, BS5514, and DIN6271. Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition. Design and specifications are subject to change without notice.
KW rating is based on LPG Fuel and may derate with natural gas.
INTERCONNECTIONS
QT048
Installation Drawing Ref. No. 0G5868
INSTALLATION LAYOUT
48/46 240 1
Ø
200
48/46 208 3
Ø
175
48/46 240 3
Ø
150
48/46 480 3 Ø 80
#6 to 300 mcm
#6 to 300 mcm
#6 to 300 mcm
#6 to 300 mcm
WEIGHT: 1740 lbs.
Generac Power Systems, Inc. • P.O. Box 8, Waukesha, WI 53187 • generac.com
©2008 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0179270SBY/Printed in U.S.A. 09.08
advertisement