SereneLife PSLHUM80 User manual

Add to My manuals
4 Pages

advertisement

SereneLife PSLHUM80 User manual | Manualzz

WARRANTY & SERVICE

We guarantee the unit TO BE free from defects in material or workmanship for a period of one (1) year from the date of purchase.

Operating this unit with an adapter other than the one supplied or any attempts made to service or modify the unit, will VOID THE WARRANTY.

For your convenience, please record the complete model number and the date of purchase below, and attach your receipt as proof of purchase.

WARM/COOL MIST ULTRASONIC HUMIDIFIER

ATTACH YOUR PURCHASE RECEIPT HERE

Serial No.:

Date of Purchase:

Name and address of Purchaser:

Telephone:

This product has been manufactured to comply with EEC Directives

73/23/EEC and 89/336/EEC

MODEL:

PSLHUM80

WHEN USING ELECTRICAL APPLIANCES, BASIC SAFETY PRECAUTIONS

SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:

1. Check the household voltage to ensure it matches the units rated specification before operating.

2. NEVER place humidifier in an area where it is accessible to children. NEVER use humidifier in a closed room, particularly where a child may be sleeping, resting, or playing.

3. DO NOT add water from moisture outlet directly, or it will hurt the unit.

4. Do not allow children to play with any product packaging, such as plastic bags.

5. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves, or heaters.

6. DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. Do locate your humidifier on an inside wall near an electrical outlet.

The humidifier should be at least 10cm away from the wall for best results.

7. Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet.

8. DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner.

Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair.

9. Always place humidifier on a firm, flat, level surface at least 60cm away from the floor.

10. DO NOT allow the moisture outlet to directly face the wall.

11. NEVER tilt, move, or attempt to empty unit while it is operating.

12. Shut off and unplug before removing the water tank and moving the unit.

13. DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.

14. Do not plug in the cord with wet hands: electric shock could result.

15. NEVER use detergents, gasoline, glass cleaner, furniture polish, and paint thinner, or other household solvents to clean any part of the humidifier.

16. Do not pour water in any openings other than the water tank.

17. Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF.

18. Never place housing under water flow or immerse in liquids.

REPLACEMENT OF THE FILTER CARTRIDGE (OPTIONAL)

1

Replace the filter cartridge every 6 months as following instructions:

·Always unplug the unit before removing the water tank. Do not touch the water in the base during operation.

·Turn the water tank upside down and unscrew the water tank cap. The filter cartridge is attached to the inside of the cap.

·Remove the old filter cartridge

·Insert the new filter cartridge into the filter support in the water tank.

Special notes: The main material of the filter cartridge is ion exchange resin.

TROUBLE SHOOTING

If your humidifier is not working correctly please check the following causes:

TROUBLE PROBABLE CAUSE SULTION

Humidifier does not operate.

The power light is on, but there is no mist with wind

The water mist produces an unpleasant smell.

Power cable not plugged in Plug in power cable

No water in water tank

New machine.

The power light is on, but the humidifier doesn’t work

The output volume of the mist is low

Dirty water or the water has been left in the water tank for too long.

Too much water in the water flume

The transducer is dirty.

Abnormal noise

Very tight tank cap

Water is too dirty or water kept too long in the tank

Resonance in water tank when water is too low

Unit is on an unstable surface

Over tightened

Fill tank with water

.

Open the water tank and leave it for 12 hours at shady and cool place.

Clean the water tank and change the water.

Pour away some water from the water flume

Clean transducer with a soft brush

Clean water tank and change the water

Fill water tank

Move the unit to a stable flat surface

Add liquid soap to cap gasket for ease opening

6

Handle

Water tank

Tank cap

Water level sensor

Transducer

Main body

CLEANING AND MAINTENANCE INSTRUCTIONS

In the winter, the lack of humidity can dry out your skin and cause irritated nasal, frequent colds, sore throats and etc. Humidifiers provide relative humidity to protect our health. To get the most of the benefit from the humidifier and avoid product failure, follow all maintenance instructions carefully. If the recommended care and maintenance guidelines are not followed, micro-organisms may be able to grow in the water within the humidifier.

DAILY MAINTENANCE

·Before cleaning, turn the power to OFF and unplug the unit from the electrical outlet.

·Lift off the tank and the housing of the humidifier.

·Carry the water tank to a sink, then drain and rinse the water tank thoroughly to remove any sediment and dirt. Wipe clean and dry with a clean soft cloth or paper towel.

·Refill the water tank with cool tap water as instructed in filling the water tank instructions.

WEEKLY MAINTENANCE

·Repeat steps 1-3 above.

·Fill one cup of white vinegar (about 200ml) to the basin for about 15 minutes, then wipe off the scale in the basin especially in the transducer with a soft brush.

·Remove the scale and white vinegar solution with a clean soft cloth.

CAUTION OF MAINTENANCE

·Make sure main body is never submerged into water

·Do not use any solvents or aggressive cleaning agents to clean the humidifier.

·Clean the inner parts with a soft cloth.

·Only use the brush to clean the transducer. This should be done once a week.

·Only use the soft-bristle portion of the brush.

·Change the water in the water tank at least once a week if water is standing for more than one week.

STORING THE HUMIDIFIER

·Clean the humidifier as described earlier and dry thoroughly.

·Preferably store the humidifier in its original box.

·Avoid high temperatures.

5

CONSUMER SAFETY INFORMATION

Note: This is an electrical appliance and requires attention when in use.

Note: If moisture forms on the walls or windows of the room, turn off the humidifier.

The room already has plenty of humidity and additional moisture may cause damage. Do not block air inlet or outlet.

CORD AND PLUG INSTALLATION SAFETY INSTRUCTIONS

The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier. Care must be taken to arrange the extension cord so that it will not drape over the countertop or table top where it can be pulled on by children or accidentally tripped over.

MAIN FEATURES

·Pre-heating the water to eliminate bacteria and viruses in the water.

·Night light(brightness adjustable) to make your life more colourful.

·Transparent water tank to ensure the water level is visible.

·Easy to adjust moisture outlet

·Advanced filter cartridge to reduce the limes in the water (optional)

·Automatically stop working when water is empty

PRE-OPERATING INSTRUCTIONS

1. Be sure the humidifier is OFF and disconnected from the electrical outlet.

2. Place the humidifier on a flat surface, about 60cm away from the floor and 10cm away from the wall. We recommend you not to place the humidifier on important furniture.

3. Filling the water tank:

- Remove the water tank and lifting straight upward. (See figure 1)

- Twist off the tank cap located on the bottom of the tank by turning counter clockwise and fill the water tank with cool, fresh water. DO NOT FILL WITH

WARM WATER AS THIS MAY CAUSE LEAKING.

- After filling the tank, replace the tank cap by firmly turning clockwise and then replace the water tank on the base. The tank will immediately begin to empty into the base.

4. Plug the power cord into a rated electrical outlet.

2

INSTRUCTIONS

B A D C

A) Warm mist switch

Press Button A to turn the heating feature ON and OFF.

B) On/Off and moisture control

Press knob B to turn the air humidifier on or off and adjust the volume of mist outlet.

C) Night Light

Turn knob C to turn the light on or off and adjust the brightness of the light.

D) Waterless warning

The indicator light (D) will flash warning when water tank must be refilled.

ATTENTION!

If condensation forms on your windows or walls, please turn the unit off.

DESCRIPTION OF THE HUMIDIFIER

3

Moisture outlet

Handle

Water tank

(Figure 1) Filter cartridge

Transducer

TECHNICAL DATA

·Product name: Warm/Cool Mist Ultrasonic Humidifier

·Input voltage: 100-240V, 50Hz/60Hz

·Moisture capacity: 400ml/h (H)

·Water tank volume: 7.0L

·Rated power: 30W (Cool Mist), 130W (Warm Mist)

·Dimension: (L x W x H): 12.8'' x 7.9'' x 13.6''

·Coverage Area: Over 430'+ Square Feet

Water tank cap

4

advertisement

Related manuals

advertisement