Lennox International Inc. G23 User's Manual


Add to my manuals
6 Pages

advertisement

Lennox International Inc. G23 User's Manual | Manualzz

PRODUCT LITERATURE

W1996 Lennox Industries Inc.

Dallas, Texas

503,517M

9/98

Supersedes 8/96

G23

SERIES

GAS FURNACE

Litho U.S.A.

WARNING

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flamĆ mable vapors and liquids in the vicinity of this or any other appliance.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WHAT TO DO IF YOU SMELL GAS:

D Do not try to light any appliance.

D Extinguish any open flames.

D Do not touch any electrical switch; do not use any phone in your building.

D Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

D If you cannot reach your gas supplier, call the fire deĆ partment.

G23 Parts Identification

TOP CAP

DURALOK TM HEAT

EXCHANGER

ASSEMBLY

VENT PIPE

CONNECTION

COMBUSTION AIR

PROVING

(PRESSURE) SWITCH

CABINET COMBUSTION AIR

BLOWER

IGNITION

CONTROL

UPPER ACCESS

PANEL

BURNERS

GAS

VALVE

GAS

MANIFOLD

BLOWER

CONTROL BOARD

BLOWER ACCESS

PANEL

CONTROL BOX

BLOWER

MOTOR

WARNING

Product contains fiberglass wool.

Disturbing the insulation in this product during installation, maintenance, or repair will expose you to fiberglass wool dust. Breathing this may cause lung cancer. (Fiberglass wool is known to the State of California to cause cancer.)

Fiberglass wool may also cause respiratory, skin, and eye irritation.

To reduce exposure to this substance or for further information, consult material safety data sheets available from address shown below, or contact your supervisor.

Lennox Industries Inc.

P.O. Box 799900

Dallas, TX 75379-9900

FIGURE 1

WARNING

Do not set thermostat below 60_F (16_C) in heating mode. Setting thermostat below 60_F (16_C) reĆ duces the number of heating cycles. Damage to the unit may occur that is not covered by the warranty.

WARNING

If overheating occurs or if gas supply fails to shut off, shut off the manual gas valve to the appliance before shutting off electrical supply.

Page 2

CAUTION

Before attempting to perform any service or mainteĆ nance, turn the electrical power to unit OFF at disĆ connect switch.

WARNING

Do not use this furnace if any part has been under water. Immediately call a qualified service techniĆ cian to inspect the furnace and to replace any part of the control system and any gas control which has been under water.

IMPORTANT

Any additions, changes, or conversions required in order for the appliance to satisfactorily meet the apĆ plication needs must be made by a Lennox service technician using factory specified and approved parts.

WARNING

Carbon monoxide gas is invisible, odorless, and toxic.

Exposure to this gas can cause personal injury and even death to all occupants, including pets. Any item that is powĆ ered by or gives off heat from a combustion process (inĆ cluding lawn mowers, automobiles, and fireplaces) has the potential to produce carbon monoxide gas. Because of this, Lennox recommends the use of a carbon monoxĆ ide detector in your home, even if you do not own gas appliances. Reliable detectors are available at reasonĆ able retail prices. Contact your independent Lennox dealer for more details about this investment in your safety.

Your furnace is designed to meet standards set by nationĆ al agencies, and to operate safely when properly installed and maintained. However, the unit's performance can be greatly impacted by the individual installation and the opĆ erating environment. It is your responsibility to ensure that this appliance is maintained. Proper maintenance is critical for your safety and the satisfactory operation of the product. Lennox strongly recommends annual inĆ spection and maintenance of this appliance. Contact your independent Lennox dealer for an inspection by a qualified service technician.

Lighting Information & Operation

Important Directions

1- Keep the furnace area clear and free of combustible material, gasoline, and other flammable vapors and liquids. If installed in an insulated area, furnace must be kept free of insulating material. Insulating material may be combustible.

2- DO NOT obstruct air flow to unit. Unit must receive an unobstructed flow of combustion and ventilating air.

3- DO NOT store chlorine or fluorine products near unit or introduce these products into the combustion air.

These products can cause furnace corrosion.

4- DO NOT draw return air from a room where this furnace, or any other gas appliance (ie., a water heater), is installed. When return air is drawn from a room, a negative pressure is created in the room. If a gas appliance is operating in a room with negative pressure, the flue products can be pulled back down the vent pipe and into the room. This reverse flow of the flue gas may result in incomplete combustion and the formation of carbon monoxide gas. This toxic gas might then be distributed throughout the house by the furnace duct system.

Your furnace is a gas appliance. It is critical that the gas supplied to the unit be completely burned to avoid the proĆ duction of carbon monoxide gas. Complete combustion of the gas requires, but is not limited to, correct gas presĆ sure and gas flow rate, adequate combustion, air, and proper venting.

Page 3

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

To place G23 furnace into operation:

G23(X) units are equipped with a SureLight ignition system. Do not attempt to manually light burners on these furnaces. Each time thermostat calls for heat, the burners will be automatically lit. The ignitor does not get hot when there is no call for heat on units with

SureLight ignition system.

Gas Valve Operation (Figure 3)

1- STOP! Read the safety information at the beginning of this section.

2- Set thermostat to lowest setting. See figure 2.

THERMOSTATS

FIGURE 2

3- Turn off all electrical power to appliance.

4- This appliance is equipped with an ignition device which automatically lights the burners. Do not try to light the burners by hand.

5- Remove upper access panel.

6- On Honeywell VR8204 gas valves, turn knob on gas valve clockwise to OFF. For White Rodgers 36E gas valves, move switch to OFF. Do not force the switch. See figure 3.

HONEYWELL VR8204 SERIES GAS VALVE

ON

OFF

GAS VALVE SHOWN IN OFF POSITION

WHITE RODGERS

36E GAS VALVE

GAS VALVE

SHOWN

IN OFF

POSITION

FIGURE 3

7- Wait fifteen (15) minutes to clear out any gas. If you then smell gas, STOP! Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you do not smell gas go to next step.

8- For Honeywell VR8204 gas valves, turn knob on gas valve counterclockwise to ON. For White RodgĆ ers 36E gas valves, move switch to ON. Do not force.

9- Replace upper access panel.

10- Turn on all electrical power to unit.

11- Set thermostat to desired setting.

Page 4

NOTE-When unit is first started, steps 1 through 11 may need to be repeated to purge air from line.

12- If the appliance still will not operate, follow the inĆ structions To Turn Off Gas To Unit" and call your serĆ vice technician or gas supplier.

Turning Off The Gas To The Unit

1- Set thermostat to lowest setting.

2- Turn off all electrical power to unit if service is to be performed.

3- Remove upper access panel.

4- On Honeywell VR8204 gas valves, turn knob on gas valve clockwise to OFF. For White Rodgers 36E gas valves, move switch to OFF. Do not force.

5- Replace upper access panel.

Filters

A filter must be in place anytime the unit is in operation. The filter may be located in the unit (optional kit) or installed in a return air grille. Ask your dealer to show you the filter location.

The filter should be inspected monthly and cleaned when necessary to assure proper furnace operation.

Filters used inside the G23 series unit are available from LenĆ nox and must be ordered separately. These foam filters may be cleaned for reuse. If replacement is necessary, order LenĆ nox part no. 31J81 for 14 X 25 inch filter for G23Q2-50,

Q3-50 and Q2/3-75 units, P-8-7822 for 16 X 25 inch filter for

G23Q3-100 units, and P-8-7831 for 20 X 25 inch filter for

G23Q3/4-100, Q3/4-125, Q4/5-75, Q4/5-100, Q5/6-125 and

Q5/6-150 units. Use the following procedure to clean filter.

Refer to figure 1.

In-Unit Filter with Bottom Return Air

1- Turn off electric power to furnace.

2- Remove blower access panel.

3- Remove filter by pressing side filter clips and pulling filter up and out. See figure 4.

BOTTOM RETURN FILTER INSTALLATION

REAR FILTER CLIP

FURNACE

BACK

SIDE FILTER CLIPS (2)

RETURN AIR OPENING

FURNACE

FRONT

FURNACE

BASE BOTĆ

FIGURE 4 TOM

4- Clean filter with cold water and a mild soap. Direct water through filter in the opposite direction of air flow. Remove all soap residue.

5- Allow filter to dry then spray with filter handicoater

(P-8-5069), available from your Lennox dealer, prior to reinstallation.

6- Place filter in bottom of blower compartment beneath rear filter clip. Press down on filter sides. Filter clips flex allowing filter to snap into place.

7- Replace blower access panel.

WARNING

Blower door must be securely in place when blower and burners are operating. Gas fumes, which could contain carbon monoxide, can be drawn into living space which could cause personal injury or death.

In-Unit Filter with Side Return Air (See Figure 5)

1- Turn off electric power to furnace.

2- Locate the filter door of the filter rack assembly.

3- Using the filter door pins, pull filter door, with filter atĆ tached, out of filter rack assembly. Remove filter door from filter by pulling up on securing tabs.

4- Clean filter with cold water and a mild soap. Direct waĆ ter through filter in the opposite direction of air flow. AlĆ low filter to dry then spray with filter handicoater, availĆ able from your Lennox dealer, prior to reinstallation.

5- Position filter door on end of filter so that the thumb tab side of the filter door is away from the furnace.

Check for correct air flow position. Squeeze thumb tabs to secure filter to door.

6- Guide filter and filter door into the filter rack installed on side of furnace. Push door into filter rack until secure.

REMOVING / REPLACING FILTER DOOR

FILTER DOOR

PIN

FILTER DOOR

FILTER DOOR

PIN

TAB

FIGURE 5

TA B

FILTER

Seasonal Inspections

A qualified service technician should inspect the comĆ plete system each season (heating and cooling). The folĆ lowing maintenance procedures should be conducted by a qualified service technician. Do not attempt to service the unit in any way.

Venting System

Annually (before heating season) inspect furnace venting system, draft hood, vent cap, heat exchanger, and burners for corrosion, deterioration, or deposits of debris. Remove any obstructions.

Inspect furnace venting system to make sure it is in place, physically sound, and without holes, corrosion, or blockage. Vent connector must be in correct position, sloped upward and be physically sound without holes or excessive corrosion.

Inspect furnace return air duct connection to ensure duct is sealed to the furnace and terminates outside the space conĆ taining the furnace.

Inspect the physical support of the furnace to guarantee that it is sound without sagging, cracks or gaps around base and it maintains seal between base and support.

During a seasonal check the service technician will inspect the indoor blower and the burner flames along with the ventĆ ing system.

Blower

Check and clean blower wheel for any debris. Blower motor is pre-lubricated for extended bearing life. No further lubricaĆ tion is needed.

Burner Flame

Burner Flame

Start burner and allow to operate for a few minutes to esĆ tablish normal burning conditions. Check burner flame by observation. Flame should be predominantly blue and strong in appearance.

CAUTION

To ensure proper operation, a qualified technician should periodically check the burner flame.

Page 5

Service Reminder

Call your Lennox service technician if unit is inoperative.

Before calling, always check the following to be sure serĆ vice is required.

1- Check that electrical disconnect switches are ON.

2- Check room thermostat for proper setting.

3- Replace any blown fuses or reset circuit breakers.

4- Gas valve should be ON.

5- Air filter should not be plugged limiting air flow.

6- Is gas turned on at meter?

7- Is manual main shut-off valve open?

Safety Precautions

If you discover any of the following, shut down your unit, and contact an independent Lennox dealer for an inspection by a qualified technician.

D

D

D

D

If you repeatedly hear any new or unfamiliar sounds while your unit is operating, there may be a problem.

For example, poorly performing burners can produce unfamiliar noises.

If you smell any unusual odors, your unit may be operĆ ating improperly. For example, units can give off unfaĆ miliar odors if components are required to operate in abnormal conditions.

Look for visible signs of a malfunctioning unit. ExamĆ ples include unusual amounts of condensate on winĆ dows inside your house, visibly burnt components or unusual dirt or rust accumulations on the vent pipe or in the unit.

If you experience headache, nausea, fatigue, or dizziĆ ness, the cause could be exposure to carbon monoxĆ ide gas. This is often misdiagnosed as the flu because symptoms are similar. If you suffer from flu-like sympĆ toms that are exaggerated at home, but seem to subĆ side while you are away from the house, exposure to carbon monoxide could be the cause.

Your vigilance may pay off in early detection of a problem before either personal injury or property damage occurs.

Do not hesitate to contact a qualified service technician as an investment in your well being.

Planned Service

You should expect a service technician to check the folĆ lowing items during an annual inspection. Power to the unit must be shut off for the service technician's safety.

Fresh air grilles and louvers (on the unit and in the room where the furnace is installed) - Must be open and unobĆ structed to provide combustion air.

Burners- Must be inspected for rust, dirt, or signs of water.

Vent pipe - Must be inspected for signs of water, damĆ aged or sagging pipe, or disconnected joints.

Unit appearance - Must be inspected for rust, dirt, signs of water, burnt or damaged wires, or components.

Blower access door - Must be properly in place and proĆ vide a seal between the return air and the room where the furnace is installed.

Return air duct - Must be properly attached and provide an air seal to unit.

Operating performance - Unit must be observed during operation to monitor proper performance of the unit and the vent system.

Combustion gases - Flue products must be analyzed and compared to the unit specifications.

Problems detected during the inspection may make it necessary to temporarily shut down the furnace until the items can be repaired or replaced.

Pay attention to your furnace. Situations can arise beĆ tween annual furnace inspections that may result in unĆ safe operation. For instance, items innocently stored next to the furnace may obstruct the combustion air supply.

This could cause incomplete combustion and the producĆ tion of carbon monoxide gas.

Page 6