SLOAN ETF-800 sensor activated hand washing faucet Installation instruction
โฆษณา
โฆษณา
Exploded Assembly View
WALL
ELECTRICAL BOX
(4” X 4”)
FAUCET/WALL
PLATE ASSEMBLY
MOUNTING PLATE
SENSOR CABLE PLASTER RING
FLEX HOSE
SET SCREW
1
Determine Mounting Location and
Cut Mounting Hole
A
Measure and mark mounting hole location on wall.
CUTOUT FOR STANDARD
4” x 4” ELECTRICAL BOX
(SUPPLIED BY OTHERS)
Electrical Box Installation Diagram
FRONT VIEW
INSTALL PLASTER
RING SO THAT
SCREW HOLES ARE
ON THE LEFT AND
RIGHT SIDE OF BOX
FINISHED WALL
OPENING
ELECTRICAL BOX
PLASTER RING
HEIGHT DETERMINED
BY CUSTOMER
INSTALLATION
TOP OF SINK
OUTLINE OF
ELECTRICAL BOX
FINISHED
TILE WALL
SIDE VIEW
FAUCET
WALL
PLATE
FINISHED
PLASTER
WALL
2
2
Install Electrical Box and Mounting
Plate to Wall
Note: Refer to Exploded Assembly View on Page 2..
A
Position and hold Electrical Box with Plaster Ring behind wall. Fasten Mounting Plate to Plaster Ring using four (4) screws. Tighten screws securely.
MOUNTING
PLATE LIP
MOUNTING
PLATE
Connect Flex Hose to Faucet
3
A
Connect Flex Hose to Faucet. Tighten fitting securely.
MOUNTING BRACKET
FLEX HOSE
ELECTRICAL
BOX
ELECTRICAL BOX
PLASTER RING
MOUNTING
SCREWS (4)
Install Faucet
4
Note: Refer to Exploded Assembly View on Page 2..
A
Feed Sensor Cable and Flex Hose through Mounting
Plate, Plaster Ring and Electrical Box.
B
Install Faucet onto Mounting Plate Lip at a slight upward angle and lower Faucet until Wall plate rests against the wall. The Faucet’s mounting bracket should be secure within the mounting lip.
C
Tighten Set Screw at bottom of Wall Plate using Hex Wrench.
3
SET SCREW
HEX WRENCH
MOUNTING
PLATE LIP
Install Solenoid Valve
5
Note: Flow direction of Solenoid Valve is indicated by an arrow on the Valve
Body.
A
Install Compression Fitting onto end of Flex Hose. Connect
3/8 inch O.D. Supply Tube between Compression Fitting on outlet side of Solenoid Valve and Compression Fitting on
Flex Hose.
SPOUT
(HEIGHT DETERMINED
BY INSTALLER)
TOP OF SINK
3/8” (10 mm)
COMPRESSION
FITTING
3/8” (10 mm)
COMPRESSION
FITTING
SOLENOID
VALVE
3/8” (10 mm)
COMPRESSION
FITTING
SENSOR
FLEX HOSE
3/8” (10 mm)
SUPPLY TUBE
(NOT SUPPLIED)
6
Connect Supply Line(s) from
Supply Stop to Solenoid Valve Inlet
Important: Keep thread sealant out of your waterway and prevent component part damage! Do not use sealant on compression fittings. When thread sealant is used, do not apply it to the first two “starter” threads.
Important: Flush dirt, debris, and sediment from the supply line(s).
A
For Dual Line Hot and Cold Water
Supply Applications the cold water supply or vice-versa. Most plumbing codes require that the Bak-Chek ® be used to prevent this.
SOLENOID
VALVE
Install a 3/8 inch (10 mm) copper supply tube between Bak-Chek ®
Compression Tee and hot and cold supply stops. (Supply tubes and stops furnished by installer.) Install a 3/8 inch
(10 mm) copper supply tube between
Bak-Chek Compression Tee and inlet side of Solenoid Valve. Tighten
Compression Fittings securely.
Note: Failure to install the Bak-Chek ® Tee can result in a cross flow connection when the faucet is off and the supply stops are open.
If pressure of the hot and cold water supply differ, hot water can migrate into
3/8” (10 mm)
SUPPLY TUBE
3/8” (10 mm)
COMPRESSION
FITTING
3/8” (10 mm)
BAK-CHEK TEE USED
ON DUAL WATER
SUPPLY
APPLICATIONS
ONLY
SUPPLY
STOP
SOLENOID
VALVE
B
For Single Line Water Supply Applications
Install a 3/8 inch (10 mm) copper supply tube between the supply stop and inlet side of Solenoid Valve. (Supply tube and stop furnished by installer.) Tighten
Compression Fittings securely.
3/8” (10 mm)
SUPPLY TUBE
3/8” (10 mm)
COMPRESSION
FITTING
SUPPLY
STOP
7
Install Transformer
Multiple Faucets
Multiple faucets can be powered by a single transformer that has been properly sized. Allow a minimum of 15 VA of current rating for each solenoid valve used.
Refer to the following example to determine the required current rating for 3
OPTIMA faucets.
Example:
Total number of OPTIMA faucets:
Total number of solenoid valves:
Multiply by current rating:
Minimum current rating of required transformer:
3
3
15 VA
——
45 VA
Transformers Available with the ETF-800 Faucets
Standard Plug-In †
Standard Box Mount
ETF-233
EL-248-40
Standard Box Mount EL-154
† In Canada, use ETF-416 (120 VAC, 35 VA)
120 VAC
120 VAC
120 VAC
35 VA
40 VA
50 VA
All Sloan transformers are 50/60 Hz.
Other transformers (not supplied by Sloan) may be used provided they meet requirements for Class 2 transformers.
4
PLUG-IN TRANSFORMERS
Important: DO NOT plug Transformer into receptacle until all wiring has been completed.
The Transformer is supplied with a 10 foot Cable; however, this Cable can and should be shortened to meet installation requirements.
A
Strip ends of Transformer Power Cable approx. 3/16 to 1/4 inch (5 to 6 mm).
CONTROL
MODULE
BASE
B
Install Strain Relief 3 inches (76 mm) from one end of Power Cable.
STRAIN
RELIEF
C
Insert Power Cable and Strain Relief into hole at back of
Control Module. Install right angle Strain Relief so that
Power Cable enters the Control Module from the bottom.
D
Connect Power Cable to Terminal Block on Connector
Board. See Step 9.
TRANSFORMER TERMINALS
E
Install Crimp Connectors and connect Power Cable ends to Transformer
Terminals.
CRIMP CONNECTORS
POWER CABLE
BOX MOUNT TRANSFORMER
Important: DO NOT supply power to primary side of Transformer until wiring is completed.
Mount Transformer on a metal electrical junction box (supplied by others). (“J” box should be mounted inside chase wall or above ceiling.) Install Transformer within 50 feet (15.24 meters) of Faucet. 18 gauge wire is recommended.
A
Run wires from secondary side of
Transformer to 3/8 inch (10 mm) hole at back of Control Module
Enclosure. If necessary, wires can be run through wall and then inserted through hole in back of
Control Module Enclosure.
24 VAC
SECONDARY
120 VAC
PRIMARY
BOX MOUNT
TRANSFORMER
(EL-248-40
SHOWN)
Mount Control Module to Wall
8
A
Install the Control Module in an appropriate location.
Control Module must be installed so that all cables enter from the bottom of the unit. When installed, Cables from the Spout and Solenoid Valve to the Control Module should have some slack.
B
Mount Control Module to wall using Mounting Screws and
Plastic Anchors.
4” (102 mm)
EXTENSION CABLES
Extension Cables are available as an option from Sloan to allow for installing the Control
Module remote from the Faucet Spout and Solenoid Valve. Refer to the Parts List for available lengths.
10
Plug In Transformer
A
Plug Transformer into 120 VAC Receptacle.
Control Module Connections
9
A
Route Cables from Solenoid Valve and Spout to the
Control Module.
B
Insert Solenoid Valve Connector into the Modular
Receptacle on Connector Board.
CONTROL
MODULE
ENCLOSURE
TERMINAL BLOCK -
1. REMOVE TERMINAL
BLOCK
2. INSERT POWER
CABLES
3. SECURE WITH
SCREWS
4. REINSTALL TERMINAL
BLOCK
MODULAR
RECEPTACLE
CONNECTOR
BOARD
POWER CABLE
STRAIN
RELIEF
SLOTS
FROM FAUCET
SPOUT
FROM SOLENOID
VALVE
FROM TRANSFORMER
C
Insert Locking Connector from Faucet Spout into mating
Receptacle on Connector Board. Allow 3 to 4 inches (76 to 102 mm) of Cable to extend into the Control Module.
D
Insert each Conduit Cable into a strain relief slot in the
Control Module.
11
Start-Up
A
Supply power to Transformer.
Note: The Control Module is equipped with two LED lights. When power is supplied by the Transformer, one LED will illuminate green. When Sensor is activated, this LED will change to red. A second red LED illuminates when
Solenoid Valve is activated.
B
Open Supply Stops. With Aerator removed, activate
Faucet for 30 seconds by placing hands in front of
Sensor. The Solenoid Valve should “click” and water should flow from the Spout. If this does not occur, refer to the Troubleshooting section of this installation instructions.
TRANSFORMER
C
Close Supply Stop(s) and install Spray Head in Spout using the Key provided. Reopen Supply Stop(s), activate
Faucet and check for leaks.
5
Range Adjustment
12
The OPTIMA ETF-800 Faucet is factory set to operate when hands are placed 4 to 5 inches (102 to 127 mm) from Sensor. This range should be satisfactory for most installations.
If range adjustment is required, refer to the following range adjustment procedures.
TO MAKE A RANGE ADJUSTMENT
The Range Potentiometer and Dip Switches are located in Control Module.
Important: Range Potentiometer adjustment screw rotates only 3/4 of a turn;
DO NOT over-rotate.
Make certain that Dip Switch number 4 is in the DOWN position. Using the small screwdriver provided, adjust Range Potentiometer clockwise until green
(power ON) indicator LED turns red (Faucet is now picking up sink). Adjust
Range Potentiometer back counterclockwise until red LED returns to green.
Range is now at maximum.
In the event the LED remains red with the adjustment at minimum
(counterclockwise) setting, the sensitivity can be further reduced by switching
Dip Switch number 4 to the ON (UP) position.
Cycle Faucet several times to assure that range as adjusted will not inadvertently pick up IR reflection in lavatory. If IR reflection occurs (green LED will flicker red), adjust Range Potentiometer counterclockwise very slightly and again cycle Faucet.
Repeat range adjustment counterclockwise until length of range is at bowl rim of lavatory (plus or minus 1 inch (25 mm)).
Time Out Adjustment
The Faucet Time Out Setting determines the maximum time the Faucet will run upon continuous activation. This timing can be changed to meet individual application requirements.
Refer to Table 1 or label on cover of Control Module along with the following instructions to set the desired Time Out. The Dip Switches used to set the Time
Out are located in the Control Module.
Set the Time Out by configuring the number 1, 2 and 3 Dip Switches as shown in Table 1.
Table 1 — Time Out Settings
Time Out
3 SECONDS
6 SECONDS
12 SECONDS
30 SECONDS
45 SECONDS
1 MINUTE
3 MINUTES
20 MINUTES
Switch #1
UP
DOWN
UP
UP
UP
DOWN
DOWN
DOWN
Dip Switch Setting
Switch #2
UP
DOWN
DOWN
DOWN
UP
UP
DOWN
UP
Switch #3
DOWN
UP
UP
DOWN
UP
UP
DOWN
DOWN
Unless otherwise specified, all ETF-800 Faucets leave the factory set with a 30 second
Time Out.
Note: The position of Dip Switch #4 (range enhancer setting) does not affect Faucet Time
Outs.
Push Cables into slots at the bottom of the Control Module.
Install Control Module cover using Screws provided.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean faucets that may dull the luster and attack the chrome or special decorative finishes. Use ONLY soap and water, then wipe dry with clean cloth or towel.
When cleaning the bathroom tile, protect the faucet from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating.
13
Test Faucet Operation
1. A continuous invisible beam of light is emitted from the
OPTIMA ® Sensor located below the faucet spout.
2. As the user’s hands enter the beam’s effective range, the beam is reflected back into the sensor receiver and activates the solenoid valve allowing tempered water to flow from the faucet. Water will flow until the hands are removed or until the faucet reaches its automatic time out limit setting.
3. When hands are moved away from the OPTIMA ® Sensor, the loss of reflected light initiates an electrical signal that deactivates the Solenoid
Valve shutting off the water flow. The Circuit then automatically resets and is ready for the next user.
6
TROUBLESHOOTING GUIDE
Note: Remove Cover from Control Module to check diagnostic lights.
1. PROBLEM: No water is delivered when Faucet is activated.
INDICATOR: If no LED lights illuminate:
CAUSE: No electricity is being supplied to Faucet.
SOLUTION: Ensure that the main power is turned “ON.” Check all
Transformer, Sensor, Solenoid and Cable Connections. Make sure that Transformer is supplying 24 VAC (Volts AC). If no voltage is detected, replace Transformer.
CAUSE: There is an electrical system malfunction.
SOLUTION: Reset electrical system. Unplug Sensor Connection.
Disconnect power to circuit for ten (10) seconds. Reconnect.
INDICATOR: If the GREEN LED illuminates when power is reconnected:
CAUSE: There is a short in the Sensor.
SOLUTION: Replace Sensor.
Note: GREEN LED may illuminate immediately after Sensor disconnection.
CAUSE: There is a short in the Solenoid or Solenoid Cable.
SOLUTION: Replace ETF-370-A Solenoid.
INDICATOR: If the GREEN LED does NOT illuminate when power is reconnected:
CAUSE: There is an electrical system malfunction.
SOLUTION: Reset electrical system. Unplug Sensor Connection.
Disconnect power to circuit for ten (10) seconds. Reconnect.
CAUSE: The Control Module circuit is “dead.”
SOLUTION: Replace ETF-450-A Control Module.
INDICATOR: If GREEN LED illuminates AND changes to RED when hands are in the Sensor’s detection zone AND the RED Solenoid LED illuminates:
CAUSE: Water supply stop(s) may be partially closed.
SOLUTION: Open supply stop(s) completely.
CAUSE: Debris is clogging Solenoid Filter.
SOLUTION: Shut off water supply. Remove, clean and reinstall Solenoid
Filter.
INDICATOR: If GREEN LED illuminates AND changes to RED when hands are placed in the Sensor’s detection zone AND the RED Solenoid
LED flickers with a vibrating/clicking noise heard inside the module:
CAUSE: There is a direct short in the Solenoid or Solenoid Cable.
SOLUTION: Replace with ETF-370-A Solenoid.
INDICATOR: If GREEN/RED LED illuminates AND changes to RED when hands are NOT located in the Sensor’s detection zone BUT the
RED Solenoid LED (in upper left corner of circuit) does NOT illuminate:
CAUSE: Sensor range is set too long and is detecting the sink.
SOLUTION: Reduce Sensor detection range.
CAUSE: Sensor is faulty.
SOLUTION: Replace Sensor.
INDICATOR: If GREEN LED illuminates BUT does NOT change to RED when hands are placed in the Sensor’s detection zone:
CAUSE: Sensor range is set too short.
SOLUTION: Increase Sensor detection range.
CAUSE: Sensor is faulty.
SOLUTION: Replace Sensor.
2. PROBLEM: Sensing Range is too short.
CAUSE: Extended Range Sensitivity is required.
SOLUTION: Dip Switch number 4 should be in the “DOWN” (Extended
Range Sensitivity) position. Increase range by adjusting
Range Potentiometer clockwise (yellow phillips screw in blue base).
3. PROBLEM: Faucet activates by itself (false triggers).
CAUSE: Sensor range is set too long.
SOLUTION: Decrease range by adjusting Range Potentiometer counterclockwise. If necessary, flip Dip Switch number 4 to the “UP” (Reduced Range Sensitivity) position. Check surroundings for factors that contribute to Sensor range detection problems (bright lights, highly reflective surfaces, sunlight, etc.).
4. PROBLEM: Faucet delivers very low flow or just a dribble.
CAUSE: Water supply stop(s) may be partially closed.
SOLUTION: Open supply stop(s) completely.
CAUSE: Debris is clogging Solenoid Filter.
SOLUTION: Shut off water. Remove, clean, and reinstall Solenoid Filter or replace Solenoid Filter ETF-1009-A.
CAUSE: Solenoid is worn or faulty.
SOLUTION: Rebuild with ETF-1009-A Solenoid Repair Kit or replace ETF-
370-A Solenoid.
CAUSE: Debris is clogging Faucet Aerator or Spray Head.
SOLUTION: Shut off water. Remove Aerator or Spray Head (use Key if required). Clean and reinstall Aerator or Spray Head.
5. PROBLEM: Faucet does not stop delivering water or continues to drip after user is no longer detected (even after power to the
Module has been disconnected).
CAUSE: Solenoid Valve is installed backward.
SOLUTION: Disconnect Solenoid. Reconnect Solenoid with water flow toward the Faucet (see arrow on Solenoid).
CAUSE: Debris is clogging Solenoid.
SOLUTION: Remove and clean Solenoid Operator. If necessary, rebuild with ETF-1009-A Repair Kit.
CAUSE: Seat in Solenoid Valve body is damaged or pitted.
SOLUTION: Replace with ETF-370-A Solenoid.
7
PARTS LIST
2A
2B
3
1
13
12
6
4
5
7
5
11
Item Part
No.
No.
1 ETF-797-A
2A ETF-687
2B ETF-801
3 EL-356
6
7
4 † ETF-530
5 † ETF-61
ETF-370-A
ETF-617-A
8
9
ETF-450-A
EL-248-40
10 ETF-233
11 ETF-458-A
12 MIX-19
13 ETF-133
† ETF-798-A
Description
Faucet Spout and Sensor Assembly
1.5 gpm/5.7 Lpm Laminar Flow Spray Head
0.5 gpm/1.9 Lpm Aerator Spray Head
Mounting Plate with Slotted Flat Head Screws (4)
Compression Fitting
Compression Fittings (2)
24 VAC Solenoid Valve Assembly; Includes Wire Harness
3/8” Bak-Chek ® Tee Compression Fitting
Control Module Assembly
Box Mount Transformer
Plug-In Transformer
Power Cable with Strain Relief and Crimp Connectors (Transformer to Control Module)
Flex Hose
Set Screw
Installation Kit, includes (1) ETF-530, (2) ETF-61 Compression Fittings, (4) Mounting Fasteners and (1) Hex Wrench
SOLENOID VALVE REPAIR KITS
— ETF-1009-A Solenoid Valve Repair Kit, Includes Replacement Filter
If further assistance is required, please contact the Sloan Valve Company Installation Engineering Department at 1-888-SLOAN-14 (1-888-756-2614).
NOTICE: The information contained in this document is subject to change without notice.
8
9
10
Copyright © 2008 SLOAN VALVE COMPANY
SLOAN VALVE COMPANY • 10500 Seymour Avenue • Franklin Park, IL 60131
Phone: 1-800-982-5839 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 www.sloanvalve.com
11-08
ดาวน์โหลด
โฆษณา