Frank W. Murphy 45HE PHE, THE, LHE, PHEF, THEF, LHEF, PHEBP, THEBP, LHEBP, LHEFP Switchgage User manual
广告
广告
FRANK W.
MFR.
®
45HE-95116B
Revised 12-96
Catalog Section 05/10/15
(00-02-0221)
4
-1/2 in.
(
114 mm
) Dial Size Hall Effect SWICHGAGE
®
45HE Series
■
Proven Hall Effect Switch Technology for
Pressure, Temperature and Level Applications
■
Easy-to-Adjust Alarm or Shutdown Set Points
■
Normally Open or Normally Closed Systems
■
Superior Switching Accuracy and Flexibility
■
Ideal for DC Powered Solid State Controllers
■
Tough Die Casted Aluminum Housing
■
Explosion-Proof Case Available
Description
The 45HE Series SWICHGAGE ® is a monitoring and alarm/shutdown device for industrial requirements. It combines state-of-the-art Hall effect switching and analog indication for Pressure,
Temperature or Level applications depending on the model used.
The 45HE is ideal for use with DC powered solid state controllers because it operates with
Normally Open or Normally Closed Systems from 4.5 to 28 VDC. 120 VAC On-Off control available in Latching Control Relay (BP) models.
Most 45HE models are available in surface mount or panel mount case designs. Dials are dual scale, single scale, and custom dials are also available.
Basic Operation
Based on our proven OPL, SPL and OPLH Series
SWICHGAGE ® models, the 45HE Series includes two magnetic-field-actuated PowerHall* transistors. When the magnetized indicating pointer meets one of the
Hall effect devices, the corresponding alarm or shutdown
Fingertip
Adjustable
Trip Point
PowerHall*
Transistor
15 transistor output signal becomes active. The 45HE trip points are fingertip adjustable.
10
60
80
100 120
20
140
160
Magnetized
Indicating
Pointer
Applications
The 45HE Series SWICHGAGE ® models accurately and reliably measure, indicate and control pressure, temperature and level in applications such as gas compressor control panels, pumping applications, industrial process applications.
45HE models are available for specific applications such as monitoring oil well lead lines, storage tank levels, automatic ON/OFF pump control, etc.
Features
PLC and Solid State Compatible
The Normally Open and Normally Closed versions of the 45HE Series are suitable for Murphy
(and others) solid state TATTLETALE ® annunciators and logic controllers, PLC’s and microprocessor-based controllers.
Low Switch Start-Up Override
A standard toggle switch is provided (N.O. and N.C.
surface mounted models) to override the low switch during equipment start-up.
Latching Control Relay (BP Model)
The 45HEBP Series includes a latching control relay for automatic ON/OFF control, either directly or through a motor starter.
Freeze-proof Sensing (FP Model)
A freeze-proof sensing device is available for the
45LHE Series level SWICHGAGE ® . The freezeproof device inserts directly into the tank wall.
The 45LHEFP sensor is stainless steel with a
Buna-N rolling diaphragm.
Optional Features
Remote Transmitter Option (-P4)
This factory-sealed, remote pressure transmitter protects the 45PHE sensing element from line pressures of highly viscous and mildly corrosive fluids.
A 5 foot (1.5 m) stainless steel capillary tube transmits pressure from the diaphragm seal to the unit.
A 1 NPTM plated steel pulsation dampener is included to help prevent damaging pulsation.
Direct Transmitter Option (-P6)
The -P6 option is the direct mounted version of the
-P4 (remote transmitter option). This factorysealed mechanism consists of a 2 NPTM plated steel diaphragm housing (304 stainless steel diaphragm housing is optional), which attaches directly to the 45PHE pressure SWICHGAGE ® .
Explosion-proof Option (-EX)
Most 45HE Series SWICHGAGE ® devices are available with an explosion-proof case for hazardous applications.
Warranty
A two-year limited warranty on materials and workmanship is given with this Murphy product.
Details are available on request and are packed with each unit.
* Allegro MicroSystems, Inc., registered trademark.
Specifications
Case: Die casted aluminum,
Dial: 4-1/2 in. (114 mm), white on black background.
Sensing Element: Bronze bourdon tube standard; 316 stainless steel or monel are optional. 45LHEA and 45LHE Level models up to 20 ft. (6.09 m) brass bellows is standard; stainless steel bellows is optional (see page 4).
Geared Movement: 302 and 304 stainless steel.
Lens: Clear Polycarbonate, UV stabilized, fog and scratch resistant.
SWICHGAGE ® Sensor: PowerHall; outputs negative signal
(sinking transistor output) rated: 300 mA continuous.
SWICHGAGE ® Set Points: 2-fingertip adjustable, visible on face-dial.
SWICHGAGE ® Electrical Connection:
Surface Mount Case: Terminal block; 1/2 NPTF conduit connection.
Panel Mount Case: Wire leads, 18 AWG x 8 in. (1.0 mm
1/2 NPTM conduit connection.
2 x 203 mm);
Optional Conduit Connection: 24 AWG x 8 in. (0.22 mm 2
1/2 NPTM conduit connection.
x 203 mm);
Operating Temperature: -40 to 185°F (-40 to +85°C).
Storage Temperature: -77 to 185°F (-60 to 85°C).
Power Input: 4.5 to 28 VDC; 120 VAC/24VDC for Latching Control
Relay (BP) models with built-in transformer/rectifier.
Overrange: Do not exceed 30% above full range (all models).
Pressure Models Sensing Connection: Bottom connection 1/4 NPTM thru
1000 psi (6.89 MPa) [68.9 bar], or 1/2 NPTM 1500 psi (10.3 MPa) [103 bar] thru 20,000 psi (137 MPa) [1378 bar], back connection optional.
Pressure Models Accuracy: ± 2% for the first and last quarters of the scale, the middle half of scale is ±1%.
Temperature Models Sensing Connections:
Capillary: 5 feet (1.5 m) PVC armored copper tube, standard.
(Other options available see “How to Order” section, page 4).
Sensing Bulb: Copper, 1/2 in. (13 mm) O.D. x 7 in. (178 mm) length;
600 psi (4.14 MPa) [41.37 bar] pressure rating, for higher pressure ratings the use of thermowell is recommended.
Sensing Bulb Connection: 1/2 NPTM.
Temperature Models Accuracy
Temperature Range Lower
1 /
4
-60 to 60°F
(-51 to 16°C)
-40 to 136°F
(-40 to 58°C)
15 to 250°F
(9 to 121°C)
130 to 350°F
(60 to 180°C)
260 to 450°F
(127 to 232°C)
± 2°F
(± 1°C)
± 4°F
(± 2°C)
± 8°F
(± 4°C)
± 8°F
(± 4°C)
± 8°F
(± 4°C)
Middle
1
± 2°F
(± 1°C)
± 2°F
(± 1°C)
± 2°F
(± 1°C)
± 2°F
(± 1°C)
± 2°F
(± 1°C)
/
2
Upper
1 /
4
± 2°F
(± 1°C)
± 2°F
(± 1°C)
± 2°F
(± 1°C)
± 3°F
(± 1.5°C)
± 3°F
(± 1.5°C)
Level Models Sensing Connections:
45LHE, 45LHEF: Bottom connection 1/4 NPTM.
Bellows Mov. Models (up to 20 ft. [6 m] range): Bottom connection 1/4 NPTF.
45LHEFP: 2 NPTM back connection.
Level Models Accuracy: ± 2% for the first and last quarters of the scale, the middle half of scale is ±1%.
Internal Wiring
Important information: When using the 45HE SWICHGAGE
®
with inductive loads, we recommend installing a suppression diode across all coil(s).
45PHE, 45THE and
45LHE Series
Note 1
45PHENC, 45THENC and 45LHENC Series
Note 2
4
45PHEBP, 45THEBP and
45LHEBP Series (12/24 VDC)
Contacts Shown Reset
(Low Limit has been Met)
Yellow
Blue
9
B
7
1
4
3
6
Brown
Black
Set
Relay Coils
A
3
5
45PHEBP, 45THEBP and
45LHEBP Series (120 VAC)
Contacts Shown Reset
(Low Limit has been Met)
4
Blue
Yellow
3
B
Set
Relay Coils
A
3
6
Brown
Black
5
3 1 2 4
= 26 AWG (0.12 mm 2 )
Red= Positive Power Input
Green= Negative Power Input
White= Low Transistor Sinking Output
Black= High Transistor Sinking Output
3 1 2 4
= 26 AWG (0.12 mm 2 )
Red= Positive Power Input
Green= Negative Power Input
White= Low Transistor Sinking Output
Black= High Transistor Sinking Output
Hall Effect Sensors Ratings: 300 mA continuous
Note 1:
Start/Run Switch; Open for Start,
Closed for Run (surface mount models only).
Note 2:
Start/Run Switch; Closed for Start,
Open for Run (surface mount models only).
8
Customer
Connections
12 or 24 VDC
+
1
Red
--
2
Green
= 26 AWG (0.12 mm 2 )
= 16 AWG (1.5 mm 2 )
Red
Reset
Red
Green
5
Low
+ –
Green
High
+ –
Customer
Connections
120 VAC
8
N
1
White
2
H
Black
Red
= 26 AWG (0.12 mm 2 )
= 18 AWG (1.0 mm 2 )
= 16 AWG (1.5 mm 2 )
Full Wave
Rectifier
Reset
Red
Green
5
Low
+ –
Green
High
+ –
Latching Relay Contact Ratings: SPDT Dry Relay Contacts, 10 A @ 120 VAC
Dimensions
Surface Mount 45PHE and 45LHE Series
4-1/32 in.
(102 mm)
8-7/16 in.
(214 mm)
3-15/16 in.
(100 mm)
3-3/8 in.
(86 mm)
Panel Mount
Square Case * models do not include mounting flange
1/2 in.
(13 mm) conduit
Panel Mount 45PHEF and 45LHEF Series
120
5-7/16 in.
(138 mm)
120
2-57/64 in.
(73 mm)
Mounting Hole
4-3/4 in.
(121 mm) diameter.
120
7-7/8 in.
(200 mm)
9/32 in.
(7 mm) dia.
3 places
* 45PHEE, 45LHEE, 45PHENCE, 45LHENCE, 45PHEBPE and 45LHEBPE models
feature square case, but altered to fit standard round panel mounting–not pictured.
1/4 in. (6 mm) dia. holes (3 places.) on
5-13/64 in. (132 mm) b.c. (bolt circle),
120 apart, clocking as shown
Optional conduit and -ES Option
1/2 in. (13 mm)
4-1/32 in.
(102 mm)
Surface Mount 45THE Series
8-7/16 in.
(214 mm)
3-15/16 in.
(100 mm)
3-3/8 in.
(86 mm)
Panel Mount
Square Case ** models do not include mounting flange
1/2 in.
(13 mm) conduit
120
Panel Mount 45THEF Series
5-7/16 in.
(138 mm)
120
2-57/64 in.
(73 mm)
7-7/8 in.
(200 mm) 9/32 in.
(7 mm) dia.
3 places
** 45THEE, 45THENCE and 45THEBPE versions feature square case,
but altered to fit standard round panel mounting–not pictured.
8 in.
(203 mm)
Explosion-proof -EX Option
8 in.
(203 mm)
6-25/64 in.
(162 mm)
3-3/8 in.
(86 mm)
6-3/4 in.
(171 mm)
1/2 NPT optional rear or side
conduit
3/8-16 UNC-2B thread
7/8 in. (22 mm) deep, 8 plc's
13/32 in.
(10 mm) diameter
4 places
3-3/8 in.
(86 mm)
6-3/4 in. (171 mm)
7-35/64 in.
(192 mm) dia.
Mounting hole required for Panel mount models
Mounting Hole
4-3/4 in.
(121 mm) diameter.
120
1/4 in. (6 mm) dia. holes (3 places.) on
5-13/64 in. (132 mm) b.c. (bolt circle),
120 apart, clocking as shown
Temperature Sensing Bulb
7 in.
(178 mm)
1/2 NPT
Bulb Minimum Insertion Compression Nut
Optional coduit and -ES
Option,
1/2 in.
(13 mm)
45LHEFP Freeze-proof
10-13/16 in.
(275 mm)
4-1/8 in.
(105 mm)
Surface Mounted Case
Process
Connection
2 NPT
How to Order
Specify model number. List options in alphabetical order (A to Z). Place a dash (–) between each option. See example below.
45PHE – R – 2 – 30 – CC
Base Models for Pressure
45PHE (surface mount)
45PHEF (panel mount)
45PHEE (panel)
†
45PHEBP
(surface)
45PHENC (surface)
45PHEFNC
(panel)
45PHENCE (panel)
†
45PHEBPE (panel)
†
Base Models for Temperature
45THE (surface mount)
45THEF (panel mount)
45THEE (panel)
†
45THEBP (surface)
45THENC (surface)
45THEFNC (panel)
45THENCE (panel)
†
45THEBPE (panel)
†
Base Models for Level
45LHE
(surface mount)
45LHEF (panel mount)
45LHEE (panel)
†
45LHEBP (surface)
45LHENC
(surface)
45LHEFNC (panel)
45LHENCE (panel)
†
45LHEBPE (panel)
†
45LHEFP
(freeze-proof)
Bourdon Tube/Bellows
A = Bronze bourdon tube with brass socket–up to 1000 psi.
= Brass bellows (level models 20 ft./6.09 m. and below only).
R = 316 Stainless steel bourdon tube with carbon steel socket.
S = 316 Stainless steel bourdon tube and socket.
= 316 Stainless steel bellows movement.
P = “K” Monel bourdon tube with monel 400 socket
(Special order. Check delivery and price.)
A1 = 1/2 NPT–up to 1000 psi.
R1 = 1/2 NPT–up to 1000 psi.
S1 = 1/2 NPT–up to 1000 psi.
P1 = 1/2 NPT–up to 1000 psi.
Latching Control Relay Voltage (for “BP” models only)
Standard * (Do not specify) = 120 VAC systems.
2 = 12 VDC systems.
3 = 24 VAC systems.
4 = 24 VDC systems.
* Includes transformer/rectifier 120VAC/24VAC.
† Features square case, but for panel mounting.
600
1000
1500
2000
3000
5000
10000
20000
30V
30V15
30V30
30V100
30V200
30V300
15
30
60
100
160
200
300
400
Pressure/Vacuum Range/Scale
30" vac - 0 psi
30" vac - 15 psi
30" vac - 30 psi
30" vac - 100 psi
30" vac - 200 psi
30" vac - 300 psi
0 - 15 psi
0 - 30 psi
0 - 60 psi
0 - 100 psi
0 - 160 psi
0 - 200 psi
0 - 300 psi
0 - 400 psi
0 - 600 psi
0 - 1000 psi
0 - 1500 psi
0 - 2000 psi
0 - 3000 psi
0 - 5000 psi
0 - 10,000 psi
0 - 20,000 psi
-101 kPa - 0 kPa
-101 kPa - 103 kPa
-101 kPa - 207 kPa
-101 kPa - 689 kPa
-101 kPa - 1.38 MPa
-101 kPa - 2.07 MPa
0 - 103 kPa
0 - 207 kPa
0 - 414 kPa
0 - 689 kPa
0 - 1.10 MPa
0 - 1.38 MPa
0 - 2.07 MPa
0 - 2.76 MPa
0 - 4.14 MPa
0 - 6.89 MPa
0 - 10.34 MPa
0 - 13.79 MPa
0 - 20.68 MPa
0 - 34.48 MPa
0 - 68.95 MPa
0 - 137.90 MPa
Options
BC = Back connected bourdon tube
CC = Conduit connection
ES = Environmentally sealed
EX = Explosion-proof
EL = Explosion-proof less case
LC = Less case
P4 = Pressure transmitter with 5 ft. (1.52 m)
P4L = Less pulsation dampener
P6 = Pressure transmitter direct mount
P6S = Pressure transmitter direct mount, 304 st. st. housing
RO = Restricting orifice
SH = Stainless steel external hardware
T3 = Tamperproof bezel/lens
TS = Over/under range stop
VR = Vapor recovery compensator
Temperature ( Specify one from each column)
Temperature Range Capillary Type Capillary Length
60 = -60 - 60°F (15.6°C)
136 = 40 - 136°F (57.8°C)
250 = 15 - 250°F (121°C)
350 = 130 - 350°F (177°C)
450 = 260 - 450°F (232°C)
P = PVC Armor/Copper Capillary
G = Galvanized/Copper Capillary
S = Stainless St./St. St. Capillary
T = Stainless St./Copper Capillary
Specify in feet
05 = 5 ft. (1.5 m)
10 = 10 ft. (3 m)
15 = 15 ft. (4.5 m) etc.
Specify in meters
1.5M = 1.5 m
2M = 2 m
2.5M = 2.5 m etc.
Level Range/Scale
Specify in feet
5
**
= 0 - 5 ft. (0-1.5 m) Dual scale
10
20
** = 0 - 10 ft. (0-3 m) Dual scale
** = 0 - 20 ft. (0-6 m) Dual scale
30 = 0 - 30 ft. (0-9 m) Dual scale
60 = 0 - 60 ft. (0-18 m) Dual scale
120 = 0 - 120 ft. Single scale
Specify in meters
4M= 0 - 4 m Single scale
3.5M= 0 - 3.5 m Single scale
6M= 0 - 6 m Single scale
90 = 0 - 9 m Single scale
** Bellows actuated level models instead of bourdon tube.
NOTES: Standard calibration is for water–specify if other. To determine correct range, add TOTAL height of liquid above the pressure connection.
For elevated tanks subtract tank elevation from gage reading to determine
ACTUAL tank level.
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
®
Since 1939 MFR.
■ Frank W. Murphy Manufacturer
P.O. Box 470248; Tulsa, Oklahoma 74147; USA
tel. (918) 627-3550 fax (918) 664-6146
e-mail [email protected]
■ Frank W. Murphy Southern Division
P.O. Box 1819; Rosenberg, Texas 77471; USA
tel. (281) 342-0297 fax (281) 341-6006
e-mail [email protected]
Printed in U.S.A.
FRANK W.
■ Frank W. Murphy, Ltd.
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
tel. +44 1722 410055 fax +44 1722 410088 tlx 477088
e-mail [email protected]
■ Frank W. Murphy Pte., Ltd.
26 Siglap Drive; Republic of Singapore 456153
tel. +65 241-3166 fax +65 241-8382
e-mail [email protected]
■ Murphek Pty., Ltd.
1620 Hume Highway; Campbellfield, Vic 3061; Australia
tel. +61 3 9358-5555 fax +61 3 9358-5558
■ Murphy de México, S.A. de C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
San Luis Potosí, S.L.P.; México 78384
tel. +52-48-206264 fax +52-48-206336
e-mail [email protected]
■ Murphy Switch of California
P.O. Box 900788; Palmdale, California 93590; USA
tel. (805) 272-4700 fax (805) 947-7570
e-mail [email protected]
■ Frank W. Murphy France
tel. +33 1 30 762626 fax +33 1 30 763989
广告