- Home
- Domestic appliances
- Large home appliances
- High-pressure cleaners
- Nilfisk-Advance America
- HSC 585
- User manual
advertisement
▼
Scroll to page 2
of 13
HSC 585 MULTI EXTRACTOR 220 - 240V EU INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL 11600205211REVA -1- 26022008 10.22.2007 IMPORTANT SAFETY INSTRUCTIONS This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops, and offices other than normal residential housekeeping purposes. When using any electrical appliance, basic precautions should always be followed, including the following: NOTE: Read all instructions before using this machine. WARNING! To reduce the risk of fire, electric shock, or injury: • Do not leave the machine unattended when it is plugged-in. Unplug the unit from the power outlet when not in use. • Unplug the machine from the power outlet before cleaning or servicing. • Turn off all controls before unplugging. • To avoid electric shock, do not expose to rain or snow. Store and use indoors. • Wear hearing protection if desired. The measured sound level of the HSC585 is 75 dB(A) • Do not allow to be used as a toy. Close attention is necessary when used near children. • Use only as described in this manual. Use only the manufacturer’s recommended attachments. • Inspect the power cord regularly for damage, such as cracking, ageing, or damaged insulation. Do not use with damaged cord or plug. If the cord needs to be replaced, take the machine to an authorized Nilfisk • If the cord or prongs become damaged have it replaced by an authorized Nilfisk service technician or partner. • Use a defoamer any time you get foam in the recovery tank, to prevent motor damage. • If foam or liquid comes out of the vacuum motor or exhaust, turn the machine off immediately. • If the machine is not working as it should, has been dropped, damaged, left outdoors or flooded with water, return it to a service center. • Do not pull the machine by the cord, do not use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners. Do not run the machine over the cord. Keep the cord away from heated surfaces.To unplug, grasp the plug, not the cord. • Do not handle the plug, the cord, or the machine with wet hands. • Extension cords must be 12/3 and no longer than 50 feet. Replace the cord or unplug immediately if the ground prong becomes damaged. • Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow. • Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes, or any health endangering dusts. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present. • Use extra care when cleaning on stairs. • Connect to a properly grounded outlet only. • Liquid pumped out could be dangerous because of temperature, pressure, or chemical content. • Do not let the pump run dry. If you run out of water, turn the machine off and refill. INSPECTION: Carefully unpack and inspect your HSC 585-MULTI for shipping damage. Each machine is tested and inspected before shipping. Any shipping damage incurred is the responsibility of the carrier. You should notify the carrier immediately if you notice damage to the box or to the machine or parts. CLEANING SOLUTIONS: Select a proper pre-spray for the surface to be cleaned, and apply the pre-spray. Use a neutral pH rinse or detergent (6 to 9 pH) in the HSC 585 to prevent premature wear of the pump, seals and other components. Powdered chemicals are not recommended. MAINTENANCE: For optimum performance, flush the machine with clear water at the end of each working day. Once a month, minimum, run a flushing compound through the machine to break up any mineral or chemical build-up that may have formed in the lines, the pumps, or the heater. The vacuum motor, pump motor, and the pump do not require any scheduled maintenance; however, the vacuum motors may require replacement brushes after 1000 - 1500 hours, and the high pressure pump and unloader valve may require rebuild kits after 500 -1000 hours (refer to machine part list for numbers). Clean the body with an all purpose detergent, and protect it with an automobile interior polish. Lubricate the wheels, castors, and quick disconnects with an allpurpose silicone spray. NOTE: to remove the complete reel with hoses from the machine, pull the vacuum hose loose from the hose barb on the front of the tank, and push the short piece of vacuum hose into the center of the hose spool. Disconnect the solution hose quick coupling. Grasp the spool from either side, and lift it off the machine. NOTE: before servicing any component in the base cabinet, remove the hoses and spool before opening the tanks. Record the serial number and model of your new extractor here: Model: HSC 585-Multi_ Serial Number: __________________ Purchase Date:_____________ Write the name and phone number of your distributor: _____________________________________ _____________________________________ 11600205211REVA -3- KNOW YOUR MACHINE HSC 585 MULTI Vacuum Hose Connection Drain Hose Drain Hose Cap Wand Holder Vacumm Tank Lid Switches Vac Tank 85 Bar Quick Disconnect Hoses Solution Tank Auto Dump Pump Power Prime Pedal Garden Hose Connector Power Cord Wheel Wheel Base Compartment Latch Castor with Brake Pressure Gauge 7 Bar Quick Disconnect HIGH PRESSURE PUMP LIGHT (NO HEAT) SWITCH PLATE I 5 I I I O O I O HEAT SELECTED LIGHT 2 PUMP/HEAT SELECTOR SWITCH 3 VACUUM ON/OFF SWITCH 4 100 PSI PUMP ON/OFF SWITCH DUMP PUMP ON/OFF SWITCH OPERATION REFER TO THE DIAGRAMS ON THE PREVIOUS PAGE CAUTION: Never leave the 85 bar pump running if you are not actively using it CAUTION: IF FOAM OR WATER COMES OUT THE VACUUM EXHAUST, TURN THE MACHINE OFF IMMEDIATELY HIGH PRESSURE WASHER 1 Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness. Make sure hoses are in good condition and the spray nozzle(s) is tight. REFER TO THE AUTO-FILL AND AUTO-DUMP INSTRUCTIONS ON THE FOLLOWING PAGES. 2. If you choose to use the automatic pump-out feature, connect the dump hose to the brass hose fitting on the back of the machine, and place the open end of the hose in a drain. Make sure the drain hose on the back of the vacuum tank is closed, and the lid is tight on the recovery tank. NOTE: never turn ON the automatic pump-out switch unless you have removed the brass cap from the hose connector on the rear of the machine. This pump will run continuously if it is turned on, and if the water can not be pumped out (cap still screwed on) damage may occur to the pump. If you choose not to use the auto pump-out option, just make sure the brass cap is on the hose connector on the rear of the machine. CAUTION: do not turn the pump-out switch on if the cap is still on the hose connector on the back of the machine. 3. If you choose to use the auto-fill feature, connect the fill-hose to the auto-fill valve (located over the solution tank fill hole). Turn on the water source. NOTE: do not turn the water on full power. The water flowing into the auto-fill system does not need a lot of pressure behind it. Allow the tank to fill with solution. When you use the auto-fill system, the auto-fill valve will automatically turn on and turn off as the tank empties and then fills. NOTE: If you are not going to use the auto-fill system, just fill the tank with water and cleaning chemical. Follow chemical directions regarding dilution and mixing. Do not use harsh chemicals; they may damage seals in pumps and valves, and cause the pump to wear prematurely. NOTE: Never put water in the tank with a temerature exceeding 54 °C/130 °F. 4. Pre-spray the area to be cleaned with a pump-up sprayer. Follow chemical directions. 5. Plug in the power cord. Turn on the high pressure pump by placing the HIGH PRESSURE/HEAT selection switch (2) in the UP position, to select the High Pressure Pump. NOTE: The high pressure pump and the heat can not operate at the same time. NOTE: this switch is off when it is set to the middle position and neither the high pressure pump nor the heater is selected. 6. The 85 bar pump is not self-priming; you will need to prime the high pressure pump using the ‘power prime’ system: turn on both the pump and the vacuum, cover the hole in the hose barb with your hand, then depress the Power Prime Pedal. This will pull trapped air out of the pump and into the recovery tank , priming the pump. You will notice a ‘tone’ change in the pump (smoother, with less of a rattle), and the water being pulled into the recovery tank will change from a white, full of air stream of continue on next page HIGH PRESSURE continued water to a clear, solid stream. Priming may take 20 - 60 seconds, or even longer sometimes, and it will require a full solution tank. When the pump is primed, let off the Power Prime Pedal, and turn off the pump and the vacuum. Then press the Power Prime Pedal once again, for a moment, to release the line pressure; you will hear a ‘swoosh’ of air as the back pressure in the lines is released. The pump will need to be primed anytime air gets into it -- try not to let the pump run dry. Proceed to the next step. 7. Add defoamer to the recovery tank. 8. Attach the solution spray hose to the solution quick disconnect. Attach the vacuum hose to the hose barb on the front of the recovery tank. Pull the hoses out from the reel. Attach the other ends of the hoses to the cleaning tool. 9. If you choose to use the automatic pump-out feature, MAKE SURE THE CAP IS REMOVED FROM THE HOSE CONNECTION ON THE BACK OF THE MACHINE BEFORE YOU TURN THE SWITCH ON. This pump will run continuously once you turn it on, and if it tries to pump out water, but the cap is still on the hose fitting, the pump may be damaged. 10. Turn on the vacuum (3) and turn on the dump pump (if you chose to use this feature) (5). Begin spraying. If you are not using the auto-fill or auto-dump features, turn off the pump and vacuum when the solution tank gets low; fill the solution tank, and empty and clean the recovery tank. If you use the auto-fill and/or auto-dump features, you will not need to stop working to fill and/or empty your tanks. 11. When the job is finished, turn off the automatic pump-out pump turn and turn off the water source, if they were employed. Use the vacuum hose to suck the remaining solution from the holding tank into the recovery tank. 13. Run a few gallons of clean water through the system. Completely empty the recovery tank by placing the drain hose over a floor drain, toilet, or tub, and removing the cap. You can clean the tank at this time with clean water. When the tank is empty, cap the drain hose and place it back in the hook and loop holder. Disconnect the hoses from the cleaning tool, and reel them up onto the hose spool. 14. Unplug the power cord. Clean the machine and the tool. LOW PRESSURE AND HEAT CAUTION: if foam or water comes out the vacuum exhaust, turn the machine off immediately 1 Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness. Make sure hoses are in good condition and the spray nozzle(s) is tight. REFER TO THE AUTO-FILL AND AUTO-DUMP INSTRUCTIONS ON THE FOLLOWING PAGE 2. If you choose to use the automatic pump-out feature, connect the dump hose to brass hose fitting on the back of the machine, and place the open end of the hose in a drain. NOTE: NEVER TURN ON THE PUMP OUT PUMP UNTIL YOU HAVE REMOVED THE CAP FROM THE HOSE CONNECTOR ON THE REAR OF THE MACHINE. Make sure the drain hose on the back of the vacuum tank is closed and the lid is tight on the recovery tank. If you are not going to use the auto pump-out option, just make sure the brass cap is on the hose connector on the rear of the machine. continue on next page LOW PRESSURE AND HEAT continued 3. If you choose to use the auto-fill feature, connect the fill-hose to the hose connection over the solution tank fill hole. Turn on the water source, and allow the tank to fill with solution. NOTE: do not turn the water on to full pressure; water flowing into the auto-fill system does not need a lot of pressure behind it. If you choose not to use the auto-fill system, just fill the tank with water and cleaning chemical. Follow chemical directions regarding dilution and mixing. Do not use harsh chemicals as they may damage seals in pumps and valves, and cause the pump to wear prematurely. NOTE: using warm water in the tank may improve the efficiency of the heat exchanger when cleaning with heat, but never use water with a temperature exceeding 54 °C/130 °F. 4. Select ‘HEAT” by moving the HEAT/HIGH PRESSURE switch towards the thermometer symbol. NOTE: this switch is off when it is set to the middle position and neither the high-pressure pump nor the heater is selected. When set to the bottom position, the heat is selected; the red light will come on and stay on. The heater and the high-pressure pump can not operate at the same time. 5. Plug in the power cord. 6. Press the ‘power prime’ pedal (located on the rear, lower left of the machine) for a moment to release any back pressure in the pump lines. 7. Connect the solution hose to the quick disconnect on the short hose from the 7 bar pump on the front of the base, and connect the vacuum hose to the hose barb on the top, left of the recovery tank. Connect the other ends of both hoses to the cleaning tool. 8. Turn on the 7 bar “demand” pump (4). NOTE: the ‘demand’ pump will not run until pressure is released. 9. Spray for a few seconds to fill the lines with solution. Wait two minutes to allow the heater to reach temperature. 10. Begin cleaning. It may take several cycles to heat the lines and the cleaning tool. 11. If you are not using the auto-fill or auto-dump features, turn off the pump and the vacuum when the solution tank gets low. Fill the solution tank, and empty and clean the recovery tank. If you are using the automatic features, your machine will empty and fill itself -- no need for you to stop working. 12. When finished with the job, turn off the water source, if using the auto-fill feature. Remove the auto-fill hose from the hose connection on the machine. Vacuum the remaining solution from the solution holding tank into the recovery tank. Run a few gallons of clean water through the system. Drain the recovery tank by placing the drain hose over a floor drain, toilet, or tub and removing the cap. You can clean the tank at this time with clean water. When the tank is empty, cap the drain hose and place it back in the hook and loop holder. Disconnect the hoses from the cleaning tool, and reel them up onto the hose spool. 13. Unplug the power cords. Clean and dry the machine and the tool. DANGER: always unplug the machine from the electrical outlet(s) before cleaning or maintaining. NOTE: before servicing any component in the base cabinet, remove the hoses and spool before opening the tanks. Refer to the instruction on page 3. USING THE AUTOMATIC-FILL AND/OR AUTOMATIC-DUMP AUTOMATIC-FILL INSTRUCTIONS Operation: 1. Attach a garden hose to the auto-fill hose connection above the holding tank fill hole, and connect the other end of the hose to your water source. 2. Make sure the float that hangs into the solution tank from the auto-fill valve is free of obstruction and can move freely. 3. Turn on the water supply. Do NOT turn the water on full pressure. This system does not require a high presssure water source. Just turn the water on. 4. The float for the automatic fill will shut-off the flow of incoming water when the tank is nearly full, and it will allow the valve to open again once the water level has dropped to a predetermined level. AUTOMATIC-FILL High Pressure Outlet Water Hose Connection AUTOMATIC-DUMP INSTRUCTIONS Operation: 1. Before each use: if necessary, unscrew the stainless steel filter inside the recovery tank and clean it. Also make sure the float in the recovery tank is clean. 2. Attach a garden hose to the automatic pump-out fitting on the back of the base of the machine (refer to illustration below). 3. Run the other end of the hose into a drain. 4. Turn on the switch for the automatic pump-out (switch is located on the switch panel on the top of the machine). NOTE: the pump out pump is ‘self-priming.’ When there is water in the recovery tank, it will automatically pump out. After each job, run clear water though the automatic pump-out to wash out any chemical residue. Remove and clean the stainless steel filter in the back of the tank. Reinstall the filter once it is clean. Empty and clean the recovery tank. Disconnect and roll up the dump hose. Clean and dry the machine and accessories. DANGER: DO NOT USE SOLVENTS, OR ANY CHEMICALS THAT MAY BE FLAMMABLE, EXPLOSIVE, OR COMBUSTIBLE. CAUTION: always use a defoamer in the recovery tank to prevent water or foam from entering the vacuum motor. AUTOMATIC-DUMP Hose Connection Dump Pump 11600205211REVA Power Prime Valve Power Prime Pedal -9- 1 2 5 3 4 6 14 7 23 9 12 8 34 11 10 24 17 21 13 19 16 25 20A 20 15 26 37 30 21A 31 29 27 18 22 28 23 HSC 585 Multi REV A 3.8.08 32 HSC 585 MULTI PART LIST 220 - 240V ITEM QTY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 16 1 17 1 18 1 19 1 20 1 20A 1 21 1 21A 1 22 1 23 1 24 1 25 1 26 1 27 1 28 1 29 1 30 1 31 1 32 1 33 1 34 1 PART No. DESCRIPTION 600758501 600758502 600758503 600758504 600758505 600758506 600758516 600758508 600758509 600758510 600758511 600758512 600758513 600758514 600758515 600758536 600758531 600758517 600758518 600758519 600758520 600758544 600758541 600758542 600758522 600758523 600758524 600758525 600758526 600758527 600758528 600758529 600758530 600758538 600758532 600758537 600758545 Reel with hoses, complete Lid kit Vacuum air inlet kit Switch plate kit Switch and light kit Auto-fill kit Vacuum tank Heater outlet kit Cord wrap kit Solution tank Fuse kit Water inlet filter kit Power prime kit Drain hose kit Power cord kit, EU Power cord kit, UK Auto-dump pump kit Vacuum motor kit Pump kit, 7 bar Pump and motor, complete, 85 bar Pump complete, 85 bar, no motor Pressure regulator, unloader valve Relay kit, vacuum motor Relay kit, pump motor Base Pressure gauge kit Glide kit, for reel Heat exchanger replacement kit Heat repair kit Low pressure pump outlet kit Castor kit (2) Louver kit Wheel kit (2) RFI filter kit Latch kit Motor, no pump (85 bar) Internal water hoses, kit MISCELLANEOUS PARTS AND KITS 1 1 1 1 1 600758521 600758533 600758534 600758535 600758540 Pump rebuild kit Vacuum hose kit, for reel Solution hose kit, for reel Label kit Water inlet filter bag (4 in kit) ALWAYS USE ONLY ORIGINAL NILFISK PARTS ON YOUR HSC 585 MULTI ACCESSORIES HFT-40 TURBO HARD SURFACE TOOL 600305899 Use on all types of hard flooring Cleaning capacity is up to 93 m2 or 1000 ft2/Hr Lightweight, but robust Brush ring attachment No wheels to restrict 360° travel Water temperature up to 110 °C / 230 °F Patented automatic vacuum compensator leaves the floor dryer • In line filter keeps spray jets clean • • • • • • • • • • • • HFT-45 HARD SURFACE COMBO TOOL HFT-43 MINI TURBO HARD SURFACE TOOL 60070045 60070043 Designed for edging hard surfaces Hose is rated to 172 bar / 500 -2500 psi Use water up to 110 °C / 230°F Heads lay flat for cleaning under fixtures Ergonomic design EVOLUTION CARPET WAND 600203099 • • • • • • Great fo getting in those small areas 35 to 172 bar / 500 -2500 psi Use it on floors or walls Lightweight but sturdy No wheels to restrict 360° travel Water temperature up to 110 °C / 230 °F IN-LINE FILTER 600709908 • Use it with the 7 bar/100 psi pump on carpets • Its light weight is less fatiguing • It recovers more water from the carpet than heavier wands • Use with heated water up to 100 °C / 215°F • Connect the filter to the water inlet of most tools • Prevents plugged spray jets • Comes apart for cleaning STAINLESS STEEL HAND TOOL HOOK AND LOOP STRAP 600203099 • • • • Use it with up to 27 bar / 400 psi Durable Reliable valve Optional in-line filter available 600709906 • Connect the filter to the water inlet of most tools • Prevents plugged spray jets • Comes apart for cleaning MX 585 MULTI SPECIFICATIONS: Vacuum: Rated Power: Pump: Suction Power: Vacuum at Nozzle: Heat: Suction Width: Weight: Dimensions: 3-stage 2950 W maximum Positive displacement, 83 bar & Demand,7 bar 372 W 30.4 KPA to 100 ºC 38 mm 89.5 KG 39”H x 21”W x 36” L NOTES: 1 00 00220055221111RREEVVAA 11 6 -6 -13-
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project