Nortel 10Gb Ethernet Switch Module Application Guide
Pubblicità
Pubblicità
Alteon OS
TM
Application Guide
Nortel 10Gb Ethernet Switch Module for IBM BladeCenter
®
Version 1.0
Part Number: 42C4911, January 2007
2350 Mission College Blvd.
Suite 600
Santa Clara, CA 95054 www.bladenetwork.net
Alteon OS Application Guide
Copyright © 2007 Blade Network Technologies, Inc., 2350 Mission College Blvd., Suite 600, Santa Clara,
California, 95054, USA. All rights reserved. Part Number: 42C4911.
This document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this document may be reproduced in any form by any means without prior written authorization of Blade Network Technologies, Inc. Documentation is provided “as is” without warranty of any kind, either express or implied, including any kind of implied or express warranty of non-infringement or the implied warranties of merchantability or fitness for a particular purpose.
U.S. Government End Users: This document is provided with a “commercial item” as defined by FAR
2.101 (Oct. 1995) and contains “commercial technical data” and “commercial software documentation” as those terms are used in FAR 12.211-12.212 (Oct. 1995). Government End Users are authorized to use this documentation only in accordance with those rights and restrictions set forth herein, consistent with FAR
12.211- 12.212 (Oct. 1995), DFARS 227.7202 (JUN 1995) and DFARS 252.227-7015 (Nov. 1995).
Blade Network Technologies, Inc. reserves the right to change any products described herein at any time, and without notice. Blade Network Technologies, Inc. assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by Blade Network
Technologies, Inc. The use and purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of Blade Network Technologies, Inc.
Originated in the USA.
Alteon OS, and Alteon are trademarks of Nortel Networks, Inc. in the United States and certain other countries. Cisco
®
and EtherChannel
®
are registered trademarks of Cisco Systems, Inc. in the United States and certain other countries. Any other trademarks appearing in this manual are owned by their respective companies.
2 42C4911, January 2007
Contents
Preface 15
What You’ll Find in This Guide 16
Chapter 1: Accessing the Switch 23
Factory-Default vs. MM assigned IP Addresses 24
Configuring management module for switch access 25
External management port setup 28
Configuring the external management interface 28
Connect to the Switch via SSH 29
Using the Browser-Based Interface 33
Configuring BBI Access via HTTP 33
Configuring BBI Access via HTTPS 33
Configuring SNMP Trap Hosts 39
Securing Access to the Switch 43
RADIUS Authentication and Authorization 44
42C4911, January 2007 3
Alteon OS Application Guide
LDAP Authentication and Authorization 53
Secure Shell and Secure Copy 55
Chapter 2: Port-based Network Access Control 67
Extensible Authentication Protocol over LAN 68
802.1x Authentication Process 69
Supported RADIUS Attributes 72
Chapter 3: VLANs 75
VLANs and Port VLAN ID Numbers 77
VLAN Topologies and Design Considerations 84
Example 1: Multiple VLANs with Tagging Adapters 85
Port-based vs. Protocol-based VLANs 88
PVLAN Configuration Guidelines 89
Chapter 4: Ports and Trunking 93
Statistical Load Distribution 95
Before you configure static trunks 95
Trunk group configuration rules 96
Configurable Trunk Hash Algorithm 100
Link Aggregation Control Protocol 101
4 42C4911, January 2007
Alteon OS Application Guide
Chapter 5: Spanning Tree Group 105
Bridge Protocol Data Units (BPDUs) 107
Determining the Path for Forwarding BPDUs 107
Spanning Tree Group configuration guidelines 108
Default Spanning Tree configuration 110
Why Do We Need Multiple Spanning Trees? 111
Switch-Centric Spanning Tree Group 111
VLAN Participation in Spanning Tree Groups 112
Configuring Multiple Spanning Tree Groups 113
Configuring Port Fast Forwarding 115
Configuring Fast Uplink Convergence 116
Chapter 6: Rapid Spanning Tree Protocol/Multiple Spanning Tree
Protocol 117
Rapid Spanning Tree Protocol 118
RSTP Configuration Guidelines 119
RSTP Configuration Example 120
Multiple Spanning Tree Protocol 121
Common Internal Spanning Tree 121
MSTP Configuration Guidelines 122
MSTP Configuration Example 122
Chapter 7: Quality of Service 123
Summary of packet classifiers 126
Understanding ACL Precedence 128
ACL Metering and Re-marking 130
42C4911, January 2007 5
Alteon OS Application Guide
ACL Configuration Examples 132
Using DSCP Values to Provide QoS 134
Differentiated Services Concepts 134
Using 802.1p Priorities to Provide QoS 139
802.1p Configuration Example 140
Chapter 8: Basic IP Routing 143
Routing Between IP Subnets 145
Dynamic Host Configuration Protocol 152
DHCP Relay Agent Configuration 154
Chapter 9: Routing Information Protocol 155
RIPv2 in RIPv1 compatibility mode 157
Chapter 10: IGMP 161
IGMP Snooping Configuration Example 163
6 42C4911, January 2007
Alteon OS Application Guide
Chapter 11: Border Gateway Protocol 171
Internal Routing Versus External Routing 172
Incoming and Outgoing Route Maps 175
Local Preference Attribute 180
Metric (Multi-Exit Discriminator) Attribute 180
Selecting Route Paths in BGP 181
BGP Failover Configuration 182
Default Redistribution and Route Aggregation Example 185
Chapter 12: OSPF 187
Types of OSPF Routing Devices 190
The Shortest Path First Tree 192
Internal Versus External Routing 192
OSPF Implementation in Alteon OS 193
Electing the Designated Router and Backup 196
Host Routes for Load Balancing 202
OSPF Features Not Supported in This Release 203
42C4911, January 2007 7
Alteon OS Application Guide
OSPF Configuration Examples 204
Example 1: Simple OSPF Domain 205
Example 3: Summarizing Routes 211
Verifying OSPF Configuration 213
Chapter 13: High Availability 217
Setting the Failover Limit 219
L2 Failover with Other Features 219
L2 Failover Configurations 220
Configuring Trunk Failover 223
Selecting the Master VRRP Router 226
Alteon OS extensions to VRRP 230
Tracking VRRP Router Priority 230
Virtual Router Deployment Considerations 231
Assigning VRRP Virtual Router ID 231
Configuring the Switch for Tracking 231
High Availability Configurations 233
Active-Active Configuration 233
8 42C4911, January 2007
Appendix A: Troubleshooting 245
Configuring Port Mirroring 251
Appendix B: RADIUS Server Configuration Notes 253
Glossary 255
Index 257
Alteon OS Application Guide
42C4911, January 2007 9
Alteon OS Application Guide
10 42C4911, January 2007
Figures
Figure 1-1:Switch management on the BladeCenter management module 26
Figure 1-2:BOOTP Relay Agent Configuration 30
Figure 1-3:DHCP Relay Agent Configuration 31
Figure 2-1:Authenticating a Port Using EAPoL 69
Figure 3-1:Default VLAN settings 81
Figure 3-2:Port-based VLAN assignment 82
Figure 3-3:802.1Q tagging (after port-based VLAN assignment) 82
Figure 3-4:802.1Q tag assignment 83
Figure 3-5:802.1Q tagging (after 802.1Q tag assignment) 83
Figure 3-6:Example 1: Multiple VLANs with VLAN-Tagged Gigabit Adapters 85
Figure 4-1:Port Trunk Group 94
Figure 4-2:Port Trunk Group Configuration Example 97
Figure 5-1:Using Multiple Instances of Spanning Tree Group 111
Figure 5-2:Implementing Multiple Spanning Tree Groups 112
Figure 7-2:Layer 3 IPv4 packet 134
Figure 7-3:Layer 2 802.1q/802.1p VLAN tagged packet 139
Figure 8-1:The Router Legacy Network 145
Figure 8-2:Switch-Based Routing Topology 146
Figure 8-3:DHCP Relay Agent Configuration 154
Figure 11-2:Distributing Network Filters in Access Lists and Route Maps 175
Figure 11-3:BGP Failover Configuration Example 182
Figure 11-4:Route Aggregation and Default Route Redistribution 185
Figure 12-1:OSPF Area Types 189
Figure 12-2:OSPF Domain and an Autonomous System 190
Figure 12-3:Injecting Default Routes 197
Figure 12-4:OSPF Authentication 200
Figure 12-5:A Simple OSPF Domain 205
Figure 12-6:Configuring a Virtual Link 207
Figure 12-7:Summarizing Routes 211
Figure 13-1:Basic Layer 2 Failover 220
Figure 13-2:Two trunks, each in a different Failover Trigger 221
42C4911, January 2007 11
Alteon OS Application Guide
Figure 13-3:Two trunks, one Failover Trigger 222
Figure 13-4:A Non-VRRP, Hot-Standby Configuration 227
Figure 13-5:Active-Active Redundancy 228
Figure 13-6:Hot-Standby Redundancy 229
Figure 13-7:Active-Active High-Availability Configuration 233
Figure 13-8:Hot-Standby Configuration 239
12 42C4911, January 2007
Tables
Table 1-1: GbESM IP addresses, based on switch-module bay numbers 24
Table 1-2: User Access Levels 47
Table 1-3: Alteon OS-proprietary Attributes for RADIUS 47
Table 1-4: Default TACACS+ Authorization Levels 49
Table 1-5: Alternate TACACS+ Authorization Levels 49
Table 4-1: Actor vs. Partner LACP configuration 101
Table 5-1: Ports, Trunk Groups, and VLANs 106
Table 7-1: Well-Known Protocol Types 126
Table 7-2: Well-Known Application Ports 127
Table 7-3: Well-Known TCP flag values 127
Table 7-4: ACL Precedence Groups 128
Table 7-5: Default QoS Service Levels 136
Table 8-1: Subnet Routing Example: IP Address Assignments 148
Table 8-2: Subnet Routing Example: IP Interface Assignments 148
Table 8-3: Subnet Routing Example: Optional VLAN Ports 150
Table 13-1: VRRP Tracking Parameters 230
42C4911, January 2007 13
Alteon OS Application Guide
14 42C4911, January 2007
Preface
The Alteon OS Application Guide describes how to configure and use the Alteon OS software on the 10Gb Ethernet Switch Module for IBM BladeCenter. For documentation on installing the switch physically, see the Installation Guide for your GbE Switch Module (GbESM).
Who Should Use This Guide
This Application Guide is intended for network installers and system administrators engaged in configuring and maintaining a network. The administrator should be familiar with Ethernet concepts, IP addressing, Spanning Tree Protocol, and SNMP configuration parameters.
42C4911, January 2007 15
Alteon OS Application Guide
What You’ll Find in This Guide
This guide will help you plan, implement, and administer Alteon OS software. Where possible, each section provides feature overviews, usage examples, and configuration instructions.
Part 1: Basic Switching
Chapter 1, “Accessing the Switch,”
describes how to access the GbE Switch Module to configure, view information and run statistics on the switch. This chapter also discusses different methods to manage the switch for remote administrators using specific IP addresses, authentication, Secure Shell (SSH), and Secure Copy (SCP).
Chapter 2, “Port-based Network Access Control,”
describes how to authenticate devices attached to a LAN port that has point-to-point connection characteristics. It prevents access to ports that fail authentication and authorization. This feature provides security to ports of the GbESM that connect to blade servers.
describes how to configure Virtual Local Area Networks (VLANs) for creating separate network segments, including how to use VLAN tagging for devices that use multiple VLANs. This chapter also describes Protocol-based VLANs, Private
VLANs, and Generic VLAN Registration Protocol (GVRP).
Chapter 4, “Ports and Trunking,”
describes how to group multiple physical ports together to aggregate the bandwidth between large-scale network devices.
Chapter 5, “Spanning Tree Group
,” discusses how Spanning Trees configure the network so that the switch uses the most efficient path when multiple paths exist.
Chapter 6, “Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol ,” describes
Rapid Spanning Tree and Multiple Spanning Tree configurations.
Chapter 7, “Quality of Service ,” discusses Quality of Service features, including IP filter-
ing using Access Control Lists, Differentiated Services, and IEEE 802.1p priority values.
Part 2: IP Routing
Chapter 8, “Basic IP Routing,”
describes how to configure the GbE Switch Module for IP routing using IP subnets, and DHCP Relay.
Chapter 9, “Routing Information Protocol
,” describes how the Alteon OS software implements standard RIP for exchanging TCP/IP route information with other routers.
describes how the Alteon OS software implements IGMP Snooping or IGMP Relay to handle multicast traffic efficiently.
16 Preface 42C4911, January 2007
Alteon OS Application Guide
Chapter 11, “Border Gateway Protocol,”
describes BGP concepts and BGP features supported in Alteon OS.
describes OSPF concepts, how OSPF is implemented in Alteon OS, and examples of how to configure your switch for OSPF support.
Part 3: High Availability Fundamentals
Chapter 13, “High Availability,”
describes how to use the Virtual Router Redundancy Protocol (VRRP) to ensure that network resources remain available if one GbE Switch Module is removed for service.
Part 4: Appendices
Appendix A, “Troubleshooting,”
discusses two tools for troubleshooting your switch— monitoring ports and filtering session dumps.
Appendix B, “RADIUS Server Configuration Notes,”
discusses how to modify RADIUS configuration files for the Nortel Networks BaySecure Access Control RADIUS server, to provide authentication for users of the GbE Switch Module.
42C4911, January 2007 Preface 17
Alteon OS Application Guide
Typographic Conventions
The following table describes the typographic styles used in this book.
Table 1 Typographic Conventions
Typeface or
Symbol
Meaning
AaBbCc123 This type is used for names of commands, files, and directories used within the text.
Example
View the readme.txt file.
It also depicts on-screen computer output and prompts.
Main#
AaBbCc123 This bold type appears in command examples. It shows text that must be typed in exactly as shown.
Main# sys
<AaBbCc123> This italicized type appears in command examples as a parameter placeholder. Replace the indicated text with the appropriate real name or value when using the command. Do not type the brackets.
To establish a Telnet session, enter: host# telnet <IP address>
This also shows book titles, special terms, or words to be emphasized.
Read your User’s Guide thoroughly.
[ ] Command items shown inside brackets are optional and can be used or excluded as the situation demands. Do not type the brackets.
host# ls [-a]
18 Preface 42C4911, January 2007
Alteon OS Application Guide
How to Get Help
If you need help, service, or technical assistance, see the "Getting help and technical assistance" appendix in the Nortel 10Gb Ethernet Switch Module for
IBM BladeCenter Installation Guide.
42C4911, January 2007 Preface 19
Alteon OS Application Guide
20 Preface 42C4911, January 2007
Part 1: Basic Switching
This section discusses basic switching functions. This includes how to access and manage the switch:
Accessing the switch
Port-Based Network Access Control
VLANs
Port Trunking
Spanning Tree Protocol
Rapid Spanning Tree and Protocol and Multiple Spanning Tree Protocol
Quality of Service
42C4911, January 2007
Alteon OS Application Guide
22 42C4911, January 2007
C HAPTER 1
Accessing the Switch
The Alteon OS software provides means for accessing, configuring, and viewing information and statistics about the GbE Switch Module. This chapter discusses different methods of accessing the switch and ways to secure the switch for remote administrators:
“Management module setup” on page 24
“External management port setup” on page 28
“Using the Browser-Based Interface” on page 33
“Securing Access to the Switch” on page 43
“RADIUS Authentication and Authorization” on page 44
“TACACS+ Authentication” on page 48
“LDAP Authentication and Authorization” on page 53
“Secure Shell and Secure Copy” on page 55
42C4911, January 2007 23
Alteon OS Application Guide
Management module setup
The BladeCenter GbE Switch Module is an integral subsystem within the overall BladeCenter system. The BladeCenter chassis includes a management module as the central element for overall chassis management and control.
You can use the management module to configure and manage the GbE Switch Module. The
GbE Switch Module communicates with the management module(s) through its internal port
15 (MGT1) and port 16 (MGT2), which you can access through the 100 Mbps Ethernet port on each management module. The factory default settings permit management and control access to the switch module only through the management module, or the built-in serial port. You can use the external Ethernet ports (EXT1-EXT7) on the switch module for management and control of the switch, by selecting this mode as an option through the management module configuration utility program (see the applicable BladeCenter Installation and User’s Guide publications for more information).
N OTE – Support for each management module is provided by a separate management port
(MGT1 and MGT2). One port is active, and the other port is used as a backup.
Factory-Default vs. MM assigned IP Addresses
Each GbE Switch Module must be assigned its own Internet Protocol address, which is used for communication with an SNMP network manager or other transmission control protocol/
Internet Protocol (TCP/IP) applications (for example, BootP or TFTP). The factory-default IP address is 10.90.90.8x, where x corresponds to the number of the bay into which the GbE
Switch Module is installed. For additional information, see the Installation Guide. The management module assigns an IP address of 192.168.70.1xx, where xx corresponds to the number of the bay into which each GbE Switch Module is installed, as shown in the following table:
Table 1-1 GbESM IP addresses, based on switch-module bay numbers
Bay number
Bay 7
Bay 8
Bay 9
Bay 10
Factory-default IP address
10.90.90.80
10.90.90.82
10.90.90.81
10.90.90.83
IP address assigned by MM
192.168.70.133
192.168.70.134
192.168.70.135
192.168.70.136
24 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
N OTE – Before you install the GbESM in Bay 8 or Bay 10, confirm that your blade
I/O Expansion adapter supports communication to these I/O bays.
Default Gateway
The default Gateway IP address determines where packets with a destination address outside the current subnet should be sent. Usually, the default Gateway is a router or host acting as an
IP gateway to handle connections to other subnets of other TCP/IP networks. If you want to access the GbE Switch Module from outside your local network, use the management module to assign a default Gateway address to the GbE Switch Module. Choose I/O Module Tasks >
Configuration from the navigation pane on the left, and enter the default Gateway IP address
(for example, 192.168.70.125). Click Save.
Configuring management module for switch access
Complete the following initial configuration steps:
1.
Connect the Ethernet port of the management module to a 10/100 Mbps network (with access to a management station) or directly to a management station.
2.
Access and log on to the management module, as described in the BladeCenter Manage-
ment Module User’s Guide. The management module provides the appropriate IP addresses for network access (see the applicable BladeCenter Installation and User’s
Guide publications for more information).
3.
Select Configuration on the I/O Module Tasks menu on the left side of the BladeCenter
Management Module window. See
42C4911, January 2007 Chapter 1: Accessing the Switch 25
Alteon OS Application Guide
Figure 1-1 Switch management on the BladeCenter management module
4.
You can use the default IP addresses provided by the management module, or you can assign a new IP address to the switch module through the management module. You can assign this IP address through one of the following methods:
Manually through the BladeCenter management module
Automatically through the IBM Director Configuration Wizard (available in
Director release 5.20.1)
N OTE – If you change the IP address of the GbE Switch Module, make sure that the switch module and the management module both reside on the same subnet.
5.
Enable the following features in the management module:
External Ports (I/O Module Tasks > Admin/Power/Restart > Advanced Setup)
External management over all ports (Configuration > Advanced Configuration)
This setting is required if you want to access the management network through the external data ports (EXT1 - EXT6) and the external management port (EXT7) on the
GbE Switch Module.
26 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
The default value is Disabled for both features. If these features are not already enabled, change the value to Enabled, then Save.
N OTE – In Advanced Configuration > Advanced Setup, enable “Preserve new IP configuration on all switch resets,” to retain the switch’s IP interface when you restore factory defaults.
This setting preserves the management port’s IP address in the management module’s memory, so you maintain connectivity to the management module after a reset.
You can now start a Telnet session, Browser-Based Interface (Web) session, a Secure Shell session, or a secure HTTPS session to the GbE Switch Module.
42C4911, January 2007 Chapter 1: Accessing the Switch 27
Alteon OS Application Guide
External management port setup
In addition to the internal management ports (MGT1 and MGT2), the 10Gb Ethernet
Switch Module (GbESM) also has an external management port (EXT7) to support out-of-band management traffic. Port EXT7 allows you to perform data transfers without taxing the data ports (EXT1-EXT6). Some commands (for example, software image transfers such as /boot/gtimg) that initiate data transfers provide an option for choosing the port over which to perform the transfer.
To use the external management port, you must configure the external management interface and gateway, as shown in the following configuration example.
Configuring the external management interface
Complete the following steps to configure port EXT7 for external management:
1.
Use Telnet to access the switch CLI, and configure the external management interface:
>> # /cfg/l3/if 249
>> IP Interface 249# addr 100.20.10.3
(Select IP interface 249)
(Assign IP address for the interface)
(Enable the interface) >> IP Interface 249# ena
>> IP Interface 249# ..
>> Layer 3# gw 253 (Select gateway 253)
>> Default gateway 253# addr 100.20.10.5 (Assign IP address for the gateway)
>> Default gateway 253# ena
>> Default gateway 253# apply
>> Default gateway 253# save
(Enable the gateway)
(Make the configuration active)
(Save your changes)
Interface 249 and gateway 253 are used for switch management through port EXT7.
2.
Enable port EXT7.
>> # /cfg/port ext7/ena
>> Port EXT7# apply
>> Port EXT7# save
(Enable port EXT7)
(Make the configuration active)
(Save your changes)
By default, port EXT7 is a member of management VLAN 4094.
Once the external management network is configured, you can start a Telnet session,
Browser-Based Interface (Web) session, a Secure Shell session, or a secure HTTPS session to the GbESM. To access the GbESM through the external management port, use the IP address for IP interface 249.
28 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
Using Telnet
Use the management module to access the GbE Switch Module through Telnet. Choose
I/O Module Tasks > Configuration from the navigation pane on the left. Select a bay number and click Advanced Configuration > Start Telnet/Web Session > Start Telnet Session. A
Telnet window opens a connection to the Switch Module (requires Java 1.4 Plug-in).
Once you have configured the GbE Switch Module with an IP address and gateway, you can access the switch from any workstation connected to the management network. Telnet access provides the same options for user and administrator access as those available through the management module, minus certain telnet and management commands.
To establish a Telnet connection with the switch, you can run the Telnet program on your workstation and issue the Telnet command, followed by the switch IP address:
telnet <switch IP address> [-m|-mgt|-e|-ext7|-d|-data]
By default, the -m or -mgt option for management ports is used. To use the internal management port, specify the -m or -mgt option. To use the external management port, specify the -e or -ext7 option.
Connect to the Switch via SSH
The SSH (Secure Shell) protocol enables you to securely log into another computer over a network to execute commands remotely. As a secure alternative to using Telnet to manage switch configuration, SSH ensures that all data sent over the network is encrypted and secure. For more information, see
“Secure Shell and Secure Copy” on page 55
. For more information on the CLI, see the Alteon OS Command Reference.
BOOTP Relay Agent
The GbE Switch Module can function as a Bootstrap Protocol relay agent, enabling the switch to forward a client request for an IP address up to two BOOTP servers with IP addresses that have been configured on the switch.
When a switch receives a BOOTP request from a BOOTP client requesting an IP address, the switch acts as a proxy for the client. The request is then forwarded as a UDP Unicast MAC layer message to two BOOTP servers whose IP addresses are configured on the switch. The servers respond to the switch with a Unicast reply that contains the default gateway and IP address for the client. The switch then forwards this reply back to the client.
42C4911, January 2007 Chapter 1: Accessing the Switch 29
Alteon OS Application Guide
Figure 1-2 shows a basic BOOTP network example.
Boston Raleigh
20.1.1.1
BladeCenter
BOOT Client asks for IP from
BOOTP server
BladeCenter acts as
BOOTP Relay Agent
Figure 1-2 BOOTP Relay Agent Configuration
10.1.1.2
BOOTP Server
The use of two servers provide failover redundancy. The client request is forwarded to both
BOOTP servers configured on the switch. However, no health checking is supported.
Configuring the BOOTP Relay Agent
To enable the GbE Switch Module to be the BOOTP forwarder, you need to configure the
BOOTP server IP addresses on the switch, and enable BOOTP relay on the interface(s) on which the BOOTP requests are received.
Generally, you should configure the command on the switch IP interface that is closest to the client, so that the BOOTP server knows from which IP subnet the newly allocated IP address should come.
Use the following commands to configure the switch as a BOOTP relay agent:
>> # /cfg/l3/bootp
>> Bootstrap Protocol Relay# addr <IP address>(IP address of BOOTP server)
>> Bootstrap Protocol Relay# addr2 <IP address>(IP address of 2nd BOOTP server)
>> Bootstrap Protocol Relay# on (Globally turn BOOTP relay on)
>> Bootstrap Protocol Relay# off
>> Bootstrap Protocol Relay# cur
(Globally turn BOOTP relay off)
(Display current configuration)
Use the following command to enable the Relay functionality on an IP interface:
>> # /cfg/l3/if <interface number>/relay ena
30 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
DHCP Relay Agent
DHCP is described in RFC 2131, and the DHCP relay agent supported on the GbESM is described in RFC 1542. DHCP uses UDP as its transport protocol. The client sends messages to the server on port 67 and the server sends messages to the client on port 68.
DHCP defines the methods through which clients can be assigned an IP address for a finite lease period and allowing reassignment of the IP address to another client later. Additionally,
DHCP provides the mechanism for a client to gather other IP configuration parameters it needs to operate in the TCP/IP network.
In the DHCP environment, the switch acts as a relay agent. The DHCP relay feature
(/cfg/l3/bootp) enables the switch to forward a client request for an IP address to two
BOOTP servers with IP addresses that have been configured on the switch.
When a switch receives a UDP broadcast on port 67 from a DHCP client requesting an IP address, the switch acts as a proxy for the client, replacing the client source IP (SIP) and destination IP (DIP) addresses. The request is then forwarded as a UDP Unicast MAC layer message to two BOOTP servers whose IP addresses are configured on the switch. The servers respond as a a UDP Unicast message back to the switch, with the default gateway and IP address for the client. The destination IP address in the server response represents the interface address on the switch that received the client request. This interface address tells the switch on which VLAN to send the server response to the client.
DHCP Relay Agent Configuration
To enable the GbESM to be the BOOTP forwarder, you need to configure the DHCP/BOOTP server IP addresses on the switch. Generally, you should configure the command on the switch
IP interface closest to the client so that the DHCP server knows from which IP subnet the newly allocated IP address should come.
The following figure shows a basic DHCP network example:
GbESM
DHCP
Server
42C4911, January 2007
Figure 1-3 DHCP Relay Agent Configuration
Chapter 1: Accessing the Switch 31
Alteon OS Application Guide
In GbESM implementation, there is no need for primary or secondary servers. The client request is forwarded to the BOOTP servers configured on the switch. The use of two servers provide failover redundancy. However, no health checking is supported.
Use the following commands to configure the switch as a DHCP relay agent:
>> # /cfg/l3/bootp
>> Bootstrap Protocol Relay# addr
>> Bootstrap Protocol Relay# addr2
>> Bootstrap Protocol Relay# on
>> Bootstrap Protocol Relay# off
>> Bootstrap Protocol Relay# cur
(Set IP address of BOOTP server)
(Set IP address of 2nd BOOTP server)
(Globally turn BOOTP relay on)
(Globally turn BOOTP relay off)
(Display current configuration)
Additionally, DHCP Relay functionality can be assigned on a per interface basis. Use the following command to enable the Relay functionality:
>> # /cfg/l3/if <interface number>/relay ena
32 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
Using the Browser-Based Interface
Use the management module to access the GbE Switch Module through a Web session. Choose
I/O Module Tasks > Configuration from the navigation pane on the left. Select a bay number and click Advanced Configuration > Start Telnet/Web Session > Start Web Session. A browser window opens a connection to the Switch Module.
The Browser-based Interface (BBI) provides access to the common configuration, management and operation features of the GbE Switch Module through your Web browser. For more information, refer to the BBI Quick Guide.
By default, BBI access is enabled on the switch (/cfg/sys/access/http ena).
Configuring BBI Access via HTTP
To enable BBI access on the switch via HTTP, use the following command:
/cfg/sys/access/http ena
The management module requires the default HTTP web server port (port 80) to access the
BBI. However, you can change the default Web server port with the following command:
/cfg/sys/access/wport <x>
For workstation access to your switch via the Browser-Based Interface, open a Web browser window and type in the URL using the IP interface address of the switch, such as http://
10.10.10.1.
Configuring BBI Access via HTTPS
The BBI can also be accessed via a secure HTTPS connection over management and data ports.
To enable BBI Access on the switch via HTTPS, use the following command:
/cfg/sys/access/https/access ena
To change the HTTPS Web server port number from the default port 443, use the following command:
/cfg/sys/access/https/port <x>
42C4911, January 2007 Chapter 1: Accessing the Switch 33
Alteon OS Application Guide
Accessing the BBI via HTTPS requires that you generate a certificate to be used during the key exchange. A default certificate is created the first time HTTPS is enabled, but you can create a new certificate defining the information you want to be used in the various fields.
>> /cfg/sys/access/https/generate
Country Name (2 letter code) [ ]: <country code>
State or Province Name (full name) []: <state>
Locality Name (eg, city) []: <city>
Organization Name (eg, company) []: <company>
Organizational Unit Name (eg, section) []: <org. unit>
Common Name (eg, YOUR name) []: <name>
Email (eg, email address) []: <email address>
Confirm generating certificate? [y/n]: y
Generating certificate. Please wait (approx 30 seconds) restarting SSL agent
The certificate can be saved to flash for use if the switch is rebooted by using the apply and save commands.
When a client (e.g. web browser) connects to the switch, they will be asked if they accept the certificate and can verify that the fields are what expected. Once BBI access is granted to the client, the BBI can be used as described in the BBI Quick Guide.
The BBI is organized at a high level as follows:
Context buttons – allow you to select the type of action you wish to perform. The Configura-
tion button provides access to the configuration elements for the entire switch. The Statistics button provides access to the switch statistics and state information. The Dashboard button allows you to display settings and operating status of a variety of switch features.
Navigation Window – provides a menu list of switch features and functions, as follows:
System – this folder provides access to the configuration elements for the entire switch.
General
User Table
Radius
TACACS+
LDAP
NTP
Boot
Syslog/Trap Features
Config/Image Control
Mgmt
34 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
Switch Ports – configure each of the physical ports on the switch.
Port-Based Port Mirroring – configure port mirroring and mirror port.
Layer 2 – Configure Quality of Service (QoS) features for the switch.
802.1x
FDB
Virtual LANs
Spanning Tree Groups
MSTP/RSTP
Failover
Trunk Groups
Trunk Hash
LACP
Uplink Fast
Layer 3 – Configure Layer 3 features for the switch.
IP Interfaces
Network Routes
Static IPMC Routes
ARP
Network Filters
Route Maps
Border Gateway Protocol
Default Gateways
IGMP
OSPF Routing Protocol
Routing Information Protocol
Virtual Router Redundancy Protocol
Domain Name System
Bootstrap Protocol Relay
General
QoS – Configure Quality of Service (QoS) features for the switch.
802.1p
DSCP
Access Control – Configure Access Control Lists to filter IP packets.
Access Control Lists
Access Control List Groups
42C4911, January 2007 Chapter 1: Accessing the Switch 35
Alteon OS Application Guide
Using SNMP
Alteon OS provides SNMP v1.0 and SNMP v3.0 support for access through any network management software, such as IBM Director or HP-OpenView.
SNMP v1.0
To access the SNMP agent on the GbESM, the read and write community strings on the SNMP manager should be configured to match those on the switch. The default read community string on the switch is public and the default write community string is private.
The read and write community strings on the switch can be changed using the following commands on the CLI:
>> /cfg/sys/ssnmp/rcomm and
>> /cfg/sys/ssnmp/wcomm
The SNMP manager should be able to reach the management interface or any one of the IP interfaces on the switch.
For the SNMP manager to receive the traps sent out by the SNMP agent on the switch
(SNMPv1 only), configure the trap host on the switch with the following command:
/cfg/sys/ssnmp/trsrc <1-250>
SNMP v3.0
SNMPv3 is an enhanced version of the Simple Network Management Protocol, approved by the Internet Engineering Steering Group in March, 2002. SNMP v3.0 contains additional security and authentication features that provide data origin authentication, data integrity checks, timeliness indicators and encryption to protect against threats such as masquerade, modification of information, message stream modification and disclosure.
SNMPv3 ensures that the client can use SNMPv3 to query the MIBs, mainly for security.
To access the SNMP v3.0 menu, enter the following command in the CLI:
>> # /cfg/sys/ssnmp/snmpv3
36 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
For more information on SNMP MIBs and the commands used to configure SNMP on the switch, see the Alteon OS Command Reference.
Default configuration
Alteon OS has two SNMP v3 users by default. Both of the following users have access to all the MIBs supported by the switch:
1) username 1: adminmd5/password adminmd5. Authentication used is MD5.
2) username 2: adminsha/password adminsha. Authentication used is SHA.
To configure an SNMP user name, enter the following command from the CLI:
>> # /cfg/sys/ssnmp/snmpv3/usm 1
User Configuration:
Users can be configured to use the authentication/privacy options. The GbESM support two authentication algorithms: MD5 and SHA, as specified in the following command:
/c/sys/ssnmp/snmpv3/usm <x>/auth md5|sha
1.
To configure a user with name 'admin,' authentication type MD5, and authentication password of 'admin,' privacy option DES with privacy password of 'admin,' use the following CLI commands.
>> # /cfg/sys/ssnmp/snmpv3/usm 5
>> SNMPv3 usmUser 5# name "admin" (Configure ‘admin’ user type)
>> SNMPv3 usmUser 5# auth md5
>> SNMPv3 usmUser 5# authpw admin
>> SNMPv3 usmUser 5# priv des
>> SNMPv3 usmUser 5# privpw admin
2.
Configure a user access group, along with the views the group may access. Use the access table to configure the group’s access level.
>> # /cfg/sys/ssnmp/snmpv3/access 5
>> SNMPv3 vacmAccess 5# name "admingrp" (Configure an access group)
>> SNMPv3 vacmAccess 5# level authPriv
>> SNMPv3 vacmAccess 5# rview "iso"
>> SNMPv3 vacmAccess 5# wview "iso"
>> SNMPv3 vacmAccess 5# nview "iso"
Because the read view (rview), write view (wview), and notify view (nview) are all set to
“iso,” the user type has access to all private and public MIBs.
42C4911, January 2007 Chapter 1: Accessing the Switch 37
Alteon OS Application Guide
3.
Assign the user to the user group. Use the group table to link the user to a particular access group.
>> # /cfg/sys/ssnmp/snmpv3/group 5
>> SNMPv3 vacmSecurityToGroup 5# uname admin
>> SNMPv3 vacmSecurityToGroup 5# gname admingrp
If you want to allow user access only to certain MIBs, see the 'View based Configuration' section.
View based Configurations
CLI User equivalent
To configure an SNMP user equivalent to the CLI 'user,' use the following configuration:
/c/sys/ssnmp/snmpv3/usm 4 (Configure the user)
name "usr"
/c/sys/ssnmp/snmpv3/access 3 (Configure access group 3)
name "usrgrp"
rview "usr"
wview "usr"
nview "usr"
/c/sys/ssnmp/snmpv3/group 4 (Assign user to access group 3)
uname usr
gname usrgrp
/c/sys/ssnmp/snmpv3/view 6 (Create views for user)
name "usr"
tree "1.3.6.1.4.1.1872.2.5.1.2" (Agent statistics)
/c/sys/ssnmp/snmpv3/view 7
name "usr"
tree "1.3.6.1.4.1.1872.2.5.1.3" (Agent information)
/c/sys/ssnmp/snmpv3/view 8
name "usr"
tree "1.3.6.1.4.1.1872.2.5.2.2" (L2 statistics)
/c/sys/ssnmp/snmpv3/view 9
name "usr"
tree "1.3.6.1.4.1.1872.2.5.2.3" (L2 information)
/c/sys/ssnmp/snmpv3/view 10
name "usr"
tree "1.3.6.1.4.1.1872.2.5.3.2" (L3 statistics)
/c/sys/ssnmp/snmpv3/view 11
name "usr"
tree "1.3.6.1.4.1.1872.2.5.3.3" (L3 information)
38 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
CLI oper equivalent
/c/sys/ssnmp/snmpv3/usm 5 (Configure the oper)
name "oper"
/c/sys/ssnmp/snmpv3/access 4 (Configure access group 4)
name "opergrp"
rview "oper"
wview "oper"
nview "oper"
/c/sys/ssnmp/snmpv3/group 4 (Assign oper to access group 4)
uname oper
gname opergrp
/c/sys/ssnmp/snmpv3/view 20 (Create views for oper)
name "usr"
tree "1.3.6.1.4.1.1872.2.5.1.2" (Agent statistics)
/c/sys/ssnmp/snmpv3/view 21
name "usr"
tree "1.3.6.1.4.1.1872.2.5.1.3" (Agent information)
/c/sys/ssnmp/snmpv3/view 22
name "usr"
tree "1.3.6.1.4.1.1872.2.5.2.2" (L2 statistics)
/c/sys/ssnmp/snmpv3/view 23
name "usr"
tree "1.3.6.1.4.1.1872.2.5.2.3" (L2 information)
/c/sys/ssnmp/snmpv3/view 24
name "usr"
tree "1.3.6.1.4.1.1872.2.5.3.2" (L3 statistics)
/c/sys/ssnmp/snmpv3/view 25
name "usr"
tree "1.3.6.1.4.1.1872.2.5.3.3" (L3 information)
Configuring SNMP Trap Hosts
SNMPv1 trap host
1.
Configure a user with no authentication and password.
/c/sys/ssnmp/snmpv3/usm 10 (Configure user named “v1trap”)
name "v1trap"
2.
Configure an access group and group table entries for the user. Use the following command to specify which traps can be received by the user
/c/sys/ssnmp/snmpv3/access <x>/nview
42C4911, January 2007 Chapter 1: Accessing the Switch 39
Alteon OS Application Guide
In the example below the user will receive the traps sent by the switch.
/c/sys/ssnmp/snmpv3/access 10 (Define access group to view SNMPv1 traps)
name "v1trap"
model snmpv1
nview "iso"
/c/sys/ssnmp/snmpv3/group 10 (Assign user to the access group)
model snmpv1
uname v1trap
gname v1trap
3.
Configure an entry in the notify table.
/c/sys/ssnmp/snmpv3/notify 10 (Assign user to the notify table)
name v1trap
tag v1trap
4.
Specify the IP address and other trap parameters in the targetAddr and targetParam tables. Use the following command to specify the user name used with this targetParam table: c/sys/ssnmp/snmpv3/tparam <x>/uname
/c/sys/ssnmp/snmpv3/taddr 10 (Define an IP address to send traps)
name v1trap
addr 47.80.23.245
taglist v1trap
pname v1param
/c/sys/ssnmp/snmpv3/tparam 10 (Specify SNMPv1 traps to send)
name v1param
mpmodel snmpv1
uname v1trap
model snmpv1
5.
Use the community table to specify which community string is used in the trap.
/c/sys/ssnmp/snmpv3/comm 10 (Define the community string)
index v1trap
name public
uname v1trap
40 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
SNMPv2 trap host configuration
The SNMPv2 trap host configuration is similar to the SNMPv1 trap host configuration.
Wherever you specify the model, use snmpv2 instead of snmpv1.
c/sys/ssnmp/snmpv3/usm 10 (Configure user named “v2trap”) name "v2trap"
/c/sys/ssnmp/snmpv3/access 10 (Define access group to view SNMPv2 traps)
name "v2trap"
model snmpv2
nview "iso"
/c/sys/ssnmp/snmpv3/group 10 (Assign user to the access group)
model snmpv2
uname v2trap
gname v2trap
/c/sys/ssnmp/snmpv3/notify 10 (Assign user to the notify table)
name v2trap
tag v2trap
/c/sys/ssnmp/snmpv3/taddr 10 (Define an IP address to send traps)
name v2trap
addr 47.81.25.66
taglist v2trap
pname v2param
/c/sys/ssnmp/snmpv3/tparam 10 (Specify SNMPv2 traps to send)
name v2param
mpmodel snmpv2c
uname v2trap
model snmpv2
/c/sys/ssnmp/snmpv3/comm 10 (Define the community string)
index v2trap
name public
uname v2trap
SNMPv3 trap host configuration
To configure a user for SNMPv3 traps, you can choose to send the traps with both privacy and authentication, with authentication only, or without privacy or authentication.
This is configured in the access table using the following commands:
/c/sys/ssnmp/snmpv3/access <x>/level
/c/sys/ssnmp/snmpv3/tparam <x>
Configure the user in the user table accordingly.
It is not necessary to configure the community table for SNMPv3 traps because the community string is not used by SNMPv3.
42C4911, January 2007 Chapter 1: Accessing the Switch 41
Alteon OS Application Guide
The following example shows how to configure a SNMPv3 user v3trap with authentication only:
/c/sys/ssnmp/snmpv3/usm 11 (Configure user named “v3trap”)
name "v3trap"
auth md5
authpw v3trap
/c/sys/ssnmp/snmpv3/access 11 (Define access group to view SNMPv3 traps)
name "v3trap"
level authNoPriv
nview "iso"
/c/sys/ssnmp/snmpv3/group 11 (Assign user to the access group)
uname v3trap
gname v3trap
/c/sys/ssnmp/snmpv3/notify 11 (Assign user to the notify table)
name v3trap
tag v3trap
/c/sys/ssnmp/snmpv3/taddr 11 (Define an IP address to send traps)
name v3trap
addr 47.81.25.66
taglist v3trap
pname v3param
/c/sys/ssnmp/snmpv3/tparam 11 (Specify SNMPv3 traps to send)
name v3param
uname v3trap
level authNoPriv (Set the authentication level)
42 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
Securing Access to the Switch
Secure switch management is needed for environments that perform significant management functions across the Internet. The following are some of the functions for secured management:
Encryption of management information exchanged between the remote administrator and
the switch: see “Secure Shell and Secure Copy” on page 55
The following sections are addressed in this section:
“RADIUS Authentication and Authorization” on page 44
“TACACS+ Authentication” on page 48
“LDAP Authentication and Authorization” on page 53
“Secure Shell and Secure Copy” on page 55
“End User Access Control” on page 61
42C4911, January 2007 Chapter 1: Accessing the Switch 43
Alteon OS Application Guide
RADIUS Authentication and Authorization
Alteon OS supports the RADIUS (Remote Authentication Dial-in User Service) method to authenticate and authorize remote administrators for managing the switch. This method is based on a client/server model. The Remote Access Server (RAS)—the switch—is a client to the back-end database server. A remote user (the remote administrator) interacts only with the
RAS, not the back-end server and database.
RADIUS authentication consists of the following components:
A protocol with a frame format that utilizes UDP over IP (based on RFC 2138 and 2866)
A centralized server that stores all the user authorization information
A client, in this case, the switch
The GbE Switch Module—acting as the RADIUS client—communicates to the RADIUS server to authenticate and authorize a remote administrator using the protocol definitions specified in RFC 2138 and 2866. Transactions between the client and the RADIUS server are authenticated using a shared key that is not sent over the network. In addition, the remote administrator passwords are sent encrypted between the RADIUS client (the switch) and the back-end RADIUS server.
How RADIUS Authentication Works
1.
Remote administrator connects to the switch and provides user name and password.
2.
Using Authentication/Authorization protocol, the switch sends request to authentication server.
3.
Authentication server checks the request against the user ID database.
4.
Using RADIUS protocol, the authentication server instructs the switch to grant or deny administrative access.
Configuring RADIUS on the Switch
Use the following procedure to configure Radius authentication on your GbE Switch Module.
For more information, see Appendix B, “RADIUS Server Configuration Notes.”
44 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
1.
Turn RADIUS authentication on, then configure the Primary and Secondary RADIUS servers.
>> Main# /cfg/sys/radius
>> RADIUS Server# on
Current status: OFF
(Select the RADIUS Server menu)
(Turn RADIUS on)
New status: ON
>> RADIUS Server# prisrv 10.10.1.1 (Enter primary server IP)
Current primary RADIUS server: 0.0.0.0
New pending primary RADIUS server: 10.10.1.1
>> RADIUS Server# secsrv 10.10.1.2 (Enter secondary server IP)
Current secondary RADIUS server: 0.0.0.0
New pending secondary RADIUS server: 10.10.1.2
2.
Configure the RADIUS secret.
>> RADIUS Server# secret
Enter new RADIUS secret: <1-32 character secret>
!
C AUTION —If you configure the RADIUS secret using any method other than through the console port or management module, the secret may be transmitted over the network as clear text.
3.
If desired, you may change the default UDP port number used to listen to RADIUS.
The well-known port for RADIUS is 1645.
>> RADIUS Server# port
Current RADIUS port: 1645
Enter new RADIUS port [1500-3000]: <UDP port number>
4.
Configure the number retry attempts for contacting the RADIUS server, and the timeout period.
>> RADIUS Server# retries
Current RADIUS server retries: 3
Enter new RADIUS server retries [1-3]: < server retries>
>> RADIUS Server# time
Current RADIUS server timeout: 3
Enter new RADIUS server timeout [1-10]: 10 (Enter the timeout period in minutes)
42C4911, January 2007 Chapter 1: Accessing the Switch 45
Alteon OS Application Guide
RADIUS Authentication Features in Alteon OS
Alteon OS supports the following RADIUS authentication features:
Supports RADIUS client on the switch, based on the protocol definitions in RFC 2138 and
RFC 2866.
Allows RADIUS secret password up to 32 bytes and less than 16 octets.
Supports secondary authentication server so that when the primary authentication server is unreachable, the switch can send client authentication requests to the secondary authentication server. Use the /cfg/sys/radius/cur command to show the currently active RADIUS authentication server.
Supports user-configurable RADIUS server retry and time-out values:
Time-out value = 1-10 seconds
Retries = 1-3
The switch will time out if it does not receive a response from the RADIUS server in 1-3 retries. The switch will also automatically retry connecting to the RADIUS server before it declares the server down.
Supports user-configurable RADIUS application port.
The default is 1645/UDP-based on RFC 2138. Port 1812 is also supported.
Allows network administrator to define privileges for one or more specific users to access the switch at the RADIUS user database.
SecurID is supported if the RADIUS server can do an ACE/Server client proxy. The password is the PIN number, plus the token code of the SecurID card.
46 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
Switch User Accounts
The user accounts listed in
can be defined in the RADIUS server dictionary file.
Table 1-2 User Access Levels
User Account
User
Operator
Administrator
Description and Tasks Performed Password
The User has no direct responsibility for switch management.
He/she can view all switch status information and statistics but cannot make any configuration changes to the switch.
user
The Operator manages all functions of the switch. The Operator can reset ports or the entire switch. oper
The super-user Administrator has complete access to all menus, information, and configuration commands on the switch, including the ability to change both the user and administrator passwords.
admin
RADIUS Attributes for Alteon OS User Privileges
When the user logs in, the switch authenticates his/her level of access by sending the RADIUS access request, that is, the client authentication request, to the RADIUS authentication server.
If the remote user is successfully authenticated by the authentication server, the switch will verify the privileges of the remote user and authorize the appropriate access. The administrator has an option to allow backdoor access via Telnet. The default is disable for Telnet access.
Backdoor access is always enabled on the console port.
N OTE – To obtain the RADIUS backdoor password for your GbESM, contact your IBM
Service and Support line.
All user privileges, other than those assigned to the Administrator, have to be defined in the
RADIUS dictionary. RADIUS attribute 6 which is built into all RADIUS servers defines the administrator. The file name of the dictionary is RADIUS vendor-dependent. The following
RADIUS attributes are defined for Alteon OS user privileges levels:
Table 1-3 Alteon OS-proprietary Attributes for RADIUS
User Name/Access
User
Operator
Admin
User-Service-Type
Vendor-supplied
Vendor-supplied
Vendor-supplied
Value
255
252
250
42C4911, January 2007 Chapter 1: Accessing the Switch 47
Alteon OS Application Guide
TACACS+ Authentication
Alteon OS supports authentication and authorization with networks using the Cisco Systems
TACACS+ protocol. The GbE Switch Module functions as the Network Access Server (NAS) by interacting with the remote client and initiating authentication and authorization sessions with the TACACS+ access server. The remote user is defined as someone requiring management access to the GbE Switch Module either through a data or management port.
TACACS+ offers the following advantages over RADIUS:
TACACS+ uses TCP-based connection-oriented transport; whereas RADIUS is UDPbased. TCP offers a connection-oriented transport, while UDP offers best-effort delivery.
RADIUS requires additional programmable variables such as re-transmit attempts and time-outs to compensate for best-effort transport, but it lacks the level of built-in support that a TCP transport offers.
TACACS+ offers full packet encryption whereas RADIUS offers password-only encryption in authentication requests.
TACACS+ separates authentication, authorization and accounting.
How TACACS+ Authentication Works
TACACS+ works much in the same way as RADIUS authentication as described on page 44
.
1.
Remote administrator connects to the switch and provides user name and password.
2.
Using Authentication/Authorization protocol, the switch sends request to authentication server.
3.
Authentication server checks the request against the user ID database.
4.
Using TACACS+ protocol, the authentication server instructs the switch to grant or deny administrative access.
During a session, if additional authorization checking is needed, the switch checks with a
TACACS+ server to determine if the user is granted permission to use a particular command.
TACACS+ Authentication Features in Alteon OS
Authentication is the action of determining the identity of a user, and is generally done when the user first attempts to log in to a device or gain access to its services. Alteon OS supports
ASCII inbound login to the device. PAP, CHAP and ARAP login methods, TACACS+ change password requests, and one-time password authentication are not supported.
48 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
Authorization
Authorization is the action of determining a user’s privileges on the device, and usually takes place after authentication.
The default mapping between TACACS+ authorization levels and Alteon OS management
access levels is shown in Table 1-4
. The authorization levels must be defined on the TACACS+ server.
Table 1-4 Default TACACS+ Authorization Levels
Alteon OS User Access Level user oper admin
TACACS+ level
0
3
6
Alternate mapping between TACACS+ authorization levels and Alteon OS management access levels is shown in
Table 1-5 . Use the command /cfg/sys/tacacs/cmap ena
to use the alternate TACACS+ authorization levels.
Table 1-5 Alternate TACACS+ Authorization Levels
Alteon OS User Access Level user oper admin
TACACS+ level
0 - 1
6 - 8
14 - 15
If the remote user is successfully authenticated by the authentication server, the switch verifies the privileges of the remote user and authorizes the appropriate access. The administrator has an option to allow backdoor access via Telnet (/cfg/sys/tacacs/telnet). The default value for Telnet access is disabled. The administrator also can enable secure backdoor
(/cfg/sys/tacacs/secbd), to allow access if both the primary and the secondary
TACACS+ servers fail to respond.
N OTE – To obtain the TACACS+ backdoor password for your GbESM, contact your IBM
Service and Support line.
42C4911, January 2007 Chapter 1: Accessing the Switch 49
Alteon OS Application Guide
Accounting
Accounting is the action of recording a user's activities on the device for the purposes of billing and/or security. It follows the authentication and authorization actions. If the authentication and authorization is not performed via TACACS+, there are no TACACS+ accounting messages sent out.
You can use TACACS+ to record and track software logins, configuration changes, and interactive commands.
The GbE Switch Module supports the following TACACS+ accounting attributes:
protocol (console/telnet/ssh/http)
start_time
stop_time
elapsed_time
disc-cause
N OTE – When using the Browser-Based Interface, the TACACS+ Accounting Stop records are sent only if the Quit button on the browser is clicked.
Command Authorization and Logging
When TACACS+ Command Authorization is enabled (/cfg/sys/tacacs/cauth ena),
Alteon OS configuration commands are sent to the TACACS+ server for authorization. When
TACACS+ Command Logging is enabled (/cfg/sys/tacacs/clog ena), Alteon OS configuration commands are logged on the TACACS+ server.
The following examples illustrate the format of Alteon OS commands sent to the TACACS+ server: authorization request, cmd=cfgtree, cmd-arg=/cfg/l3/if accounting request, cmd=/cfg/l3/if, cmd-arg=1 authorization request, cmd=cfgtree, cmd-arg=/cfg/l3/if/ena accounting request, cmd=/cfg/l3/if/ena authorization request, cmd=cfgtree, cmd-arg=/cfg/l3/if/addr accounting request, cmd=/cfg/l3/if/addr, cmd-arg=10.90.90.91
authorization request, cmd=apply accounting request, cmd=apply
50 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
The following rules apply to TACACS+ command authorization and logging:
Only commands from a Console, Telnet, or SSH connection are sent for authorization and logging. SNMP, BBI, or file-copy commands (for example, TFTP or sync) are not sent.
Only leaf-level commands are sent for authorization and logging. For example, /cfg is not sent, but /cfg/l3/tacacs/cauth is sent.
The full path of each command is sent for authorization and logging. For example,
/cfg/sys/tacacs/cauth
Command arguments are not sent for authorization. For /cauth ena, only /cauth is authorized. The command and its first argument are logged, if issued on the same line.
Only executed commands are logged.
Invalid commands are checked by Alteon OS, and are not sent for authorization or logging.
Authorization is performed on each leaf-level command separately. If the user issues multiple commands at once, each command is sent separately as a full path.
Only the following global commands are sent for authorization and logging: apply diff ping revert save telnet traceroute
TACACS+ Password Change
Alteon OS supports TACACS+ password change. When enabled, users can change their passwords after successful TACACS+ authorization. Use the command
/cfg/sys/tacacs/passch to enable or disable this feature.
Use the following commands to change the password for the primary and secondary
TACACS+ servers:
>> # /cfg/sys/tacacs/chpass_p (Change primary TACACS+ password)
>> # /cfg/sys/tacacs/chpass_s (Change secondary TACACS+ password)
42C4911, January 2007 Chapter 1: Accessing the Switch 51
Alteon OS Application Guide
Configuring TACACS+ Authentication on the Switch
1.
Turn TACACS+ authentication on, then configure the Primary and Secondary
TACACS+ servers.
>> Main# /cfg/sys/tacacs+
>> TACACS+ Server# on
Current status: OFF
(Select the TACACS+ Server menu)
(Turn TACACS+ on)
New status: ON
>> TACACS+ Server# prisrv 10.10.1.1 (Enter primary server IP)
Current primary TACACS+ server: 0.0.0.0
New pending primary TACACS+ server: 10.10.1.1
>> TACACS+ Server# secsrv 10.10.1.2 (Enter secondary server IP)
Current secondary TACACS+ server: 0.0.0.0
New pending secondary TACACS+ server: 10.10.1.2
2.
Configure the TACACS+ secret and second secret.
>> TACACS+ Server# secret
Enter new TACACS+ secret: <1-32 character secret>
>> TACACS+ Server# secret2
Enter new TACACS+ second secret: <1-32 character secret>
!
C AUTION —If you configure the TACACS+ secret using any method other than a direct console connection or through a secure management module connection, the secret may be transmitted over the network as clear text.
3.
If desired, you may change the default TCP port number used to listen to TACACS+.
The well-known port for TACACS+ is 49.
>> TACACS+ Server# port
Current TACACS+ port: 49
Enter new TACACS+ port [1-65000]: <port number>
4.
Configure the number of retry attempts, and the timeout period.
>> TACACS+ Server# retries
Current TACACS+ server retries: 3
Enter new TACACS+ server retries [1-3]:
>> TACACS+ Server# time
< server retries>
Current TACACS+ server timeout: 5
Enter new TACACS+ server timeout [4-15]: 10 (Enter the timeout period in minutes)
5.
Apply and save the configuration.
52 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
LDAP Authentication and Authorization
Alteon OS supports the LDAP (Lightweight Directory Access Protocol) method to authenticate and authorize remote administrators to manage the switch. LDAP is based on a client/ server model. The switch acts as a client to the LDAP server. A remote user (the remote administrator) interacts only with the switch, not the back-end server and database.
LDAP authentication consists of the following components:
A protocol with a frame format that utilizes TCP over IP
A centralized server that stores all the user authorization information
A client, in this case, the switch
Each entry in the LDAP server is referenced by its Distinguished Name (DN). The DN consists of the user-account name concatenated with the LDAP domain name. If the user-account name is John, the following is an example DN: uid=John,ou=people,dc=domain,dc=com
Configuring the LDAP Server
GbESM user groups and user accounts must reside within the same domain. On the LDAP server, configure the domain to include GbESM user groups and user accounts, as follows:
User Accounts:
Use the uid attribute to define each individual user account.
User Groups:
Use the members attribute in the groupOfNames object class to create the user groups. The first word of the common name for each user group must be equal to the user group names defined in the GbESM, as follows:
admin
oper user
42C4911, January 2007 Chapter 1: Accessing the Switch 53
Alteon OS Application Guide
Configuring LDAP Authentication on the Switch
1.
Turn LDAP authentication on, then configure the Primary and Secondary LDAP servers.
>> Main# /cfg/sys/ldap
>> LDAP Server# on
(Select the LDAP Server menu)
(Turn LDAP on)
Current status: OFF
New status: ON
>> LDAP Server# prisrv 10.10.1.1
Current primary LDAP server: 0.0.0.0
New pending primary LDAP server: 10.10.1.1
(Enter primary server IP)
>> LDAP Server# secsrv 10.10.1.2 (Enter secondary server IP)
Current secondary LDAP server: 0.0.0.0
New pending secondary LDAP server: 10.10.1.2
2.
Configure the domain name.
>> LDAP Server# domain
Current LDAP domain name: ou-people,dc=domain,dc=com
Enter new LDAP domain name: ou=people,dc=mydomain,dc=com
3.
If desired, you may change the default TCP port number used to listen to LDAP.
The well-known port for LDAP is 389.
>> LDAP Server# port
Current LDAP port: 389
Enter new LDAP port [1-65000]: <port number>
4.
Configure the number of retry attempts for contacting the LDAP server, and the timeout period.
>> LDAP Server# retries
Current LDAP server retries: 3
Enter new LDAP server retries [1-3]: < server retries>
>> LDAP Server# timeout
Current LDAP server timeout: 5
Enter new LDAP server timeout [4-15]: 10 (Enter the timeout period in minutes)
5.
Apply and save the configuration.
54 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
Secure Shell and Secure Copy
Secure Shell (SSH) and Secure Copy (SCP) use secure tunnels to encrypt and secure messages between a remote administrator and the switch. Telnet does not provide this level of security.
The Telnet method of managing a GbE Switch Module does not provide a secure connection.
SSH is a protocol that enables remote administrators to log securely into the GbE Switch Module over a network to execute management commands.
SCP is typically used to copy files securely from one machine to another. SCP uses SSH for encryption of data on the network. On a GbE Switch Module, SCP is used to download and upload the switch configuration via secure channels.
The benefits of using SSH and SCP are listed below:
Authentication of remote administrators
Identifying the administrator using Name/Password
Authorization of remote administrators
Determining the permitted actions and customizing service for individual administrators
Encryption of management messages
Encrypting messages between the remote administrator and switch
Secure copy support
The Alteon OS implementation of SSH supports both versions 1.5 and 2.0. and supports SSH clients version 1.5 - 2.x. The following SSH clients have been tested
SSH 1.2.23 and SSH 1.2.27 for Linux (freeware)
SecureCRT 3.0.2 and SecureCRT 3.0.3 for Windows NT (Van Dyke Technologies, Inc.)
F-Secure SSH 1.1 for Windows (Data Fellows)
Putty SSH
Cygwin OpenSSH
Mac X OpenSSH
Solaris 8 OpenSSH
AxeSSH SSHPro
SSH Communications Vandyke SSH A
F-Secure
42C4911, January 2007 Chapter 1: Accessing the Switch 55
Alteon OS Application Guide
Configuring SSH/SCP features on the switch
Before you can use SSH commands, use the following commands to turn on SSH/SCP. SSH and SCP are disabled by default.
To enable or disable the SSH feature:
Begin a Telnet session from the console port and enter the following commands:
(Turn SSH on) >> # /cfg/sys/sshd/on
Current status: OFF
New status: ON
>> # /cfg/sys/sshd/off
Current status: ON
New status: OFF
(Turn SSH off)
To enable or disable SCP apply and save:
Enter the following commands from the switch CLI to enable the SCP putcfg_apply and putcfg_apply_save commands:
>> # /cfg/sys/sshd/ena
SSHD# apply
(Enable SCP apply and save)
(Apply the changes to start generating RSA
host and server keys)
RSA host key generation starts
.............................................................
......................................................
RSA host key generation completes (lasts 212549 ms)
RSA host key is being saved to Flash ROM, please don't reboot the box immediately.
RSA server key generation starts
............................................................
RSA server key generation completes (lasts 75503 ms)
RSA server key is being saved to Flash ROM, please don't reboot the box immediately.
------------------------------------------------------------------
Apply complete; don't forget to "save" updated configuration.
>> # /cfg/sys/sshd/dis (Disable SSH/SCP apply and save)
56 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
Configuring the SCP Administrator Password
To configure the scpadm (SCP Administrator) password, first connect to the switch via the serial console port. For security reasons, the scpadm password may only be configured when connected through the console port.
To configure the password, enter the following command via the CLI. At factory default settings, the current SCP administrator password is admin.
>> /cfg/sys/sshd/scpadm
Changing SCP-only Administrator password; validation required...
Enter current administrator password: <password>
Enter new SCP-only administrator password: <new password>
Re-enter new SCP-only administrator password: <new password>
New SCP-only administrator password accepted.
Using SSH and SCP Client Commands
This section shows the format for using some client commands. The examples below use
205.178.15.157 as the IP address of a sample switch.
To log in to the switch:
Syntax: ssh <switch IP address> or ssh -l <login-name> <switch IP address>
Example:
>> # ssh 205.178.15.157
>> # ssh -l <login-name> 205.178.15.157 (Login to the switch)
To download the switch configuration using SCP:
Syntax: scp <username>@<switch IP address>:getcfg <local filename>
Example:
>> # scp [email protected]:getcfg ad4.cfg
42C4911, January 2007 Chapter 1: Accessing the Switch 57
Alteon OS Application Guide
To upload the configuration to the switch:
Syntax: scp <local filename> <username>@<switch IP address>:putcfg
Example:
>> # scp ad4.cfg [email protected]:putcfg
To apply and save the configuration
The apply and save commands are still needed after the last command, or use the following commands:
>> # scp ad4.cfg [email protected]:putcfg_apply
>> # scp ad4.cfg [email protected]:putcfg_apply_save
The diff command is automatically executed at the end of putcfg to notify the remote client of the difference between the new and the current configurations.
putcfg_apply runs the apply command after the putcfg is done.
putcfg_apply_save saves the new configuration to the flash after putcfg_apply is done.
The putcfg_apply and putcfg_apply_save commands are provided because extra apply and save commands are usually required after a putcfg; however, an
SCP session is not in an interactive mode at all.
SSH and SCP Encryption of Management Messages
The following encryption and authentication methods are supported for SSH and SCP:
Server Host Authentication:
Key Exchange:
Encryption:
User Authentication:
Client RSA authenticates the switch at the beginning of every connection
RSA
3DES-CBC, DES
Local password authentication, RADIUS, SecurID
(via RADIUS, TACACS+, for SSH only—does not apply to SCP)
58 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
Generating RSA Host and Server Keys for SSH Access
To support the SSH server feature, two sets of RSA keys (host and server keys) are required.
The host key is 1024 bits and is used to identify the GbE Switch Module. The server key is 768 bits and is used to make it impossible to decipher a captured session by breaking into the GbE
Switch Module at a later time.
When the SSH server is first enabled and applied, the switch automatically generates the RSA host and server keys and is stored in the FLASH memory.
N OTE – To configure RSA host and server keys, first connect to the GbE Switch Module through the console port (commands are not available via external Telnet connection), and enter the following commands to generate them manually.
>> # /cfg/sys/sshd/hkeygen
>> # /cfg/sys/sshd/skeygen
(Generates the host key)
(Generates the server key)
These two commands take effect immediately without the need of an apply command.
When the switch reboots, it will retrieve the host and server keys from the FLASH memory. If these two keys are not available in the flash and if the SSH server feature is enabled, the switch automatically generates them during the system reboot. This process may take several minutes to complete.
The switch can also automatically regenerate the RSA server key. To set the interval of RSA server key autogeneration, use this command:
>> # /cfg/sys/sshd/intrval <number of hours (0-24)>
A value of 0 (zero) denotes that RSA server key autogeneration is disabled. When greater than
0, the switch will autogenerate the RSA server key every specified interval; however, RSA server key generation is skipped if the switch is busy doing other key or cipher generation when the timer expires.
N OTE – The switch will perform only one session of key/cipher generation at a time. Thus, an
SSH/SCP client will not be able to log in if the switch is performing key generation at that time, or if another client has logged in immediately prior. Also, key generation will fail if an
SSH/SCP client is logging in at that time.
42C4911, January 2007 Chapter 1: Accessing the Switch 59
Alteon OS Application Guide
SSH/SCP Integration with Radius Authentication
SSH/SCP is integrated with RADIUS authentication. After the RADIUS server is enabled on the switch, all subsequent SSH authentication requests will be redirected to the specified
RADIUS servers for authentication. The redirection is transparent to the SSH clients.
SSH/SCP Integration with TACACS+ Authentication
SSH/SCP is integrated with TACACS+ authentication. After the TACACS+ server is enabled on the switch, all subsequent SSH authentication requests will be redirected to the specified
TACACS+ servers for authentication. The redirection is transparent to the SSH clients.
SecurID Support
SSH/SCP can also work with SecurID, a token card-based authentication method. The use of
SecurID requires the interactive mode during login, which is not provided by the SSH connection.
N OTE – There is no SNMP or Browser-Based Interface (BBI) support for SecurID because the
SecurID server, ACE, is a one-time password authentication and requires an interactive session.
Using SecurID with SSH
Using SecurID with SSH involves the following tasks.
To log in using SSH, use a special username, “ace,” to bypass the SSH authentication.
After an SSH connection is established, you are prompted to enter the username and password (the SecurID authentication is being performed now).
Provide your username and the token in your SecurID card as a regular Telnet user.
Using SecurID with SCP
Using SecurID with SCP can be accomplished in two ways:
Using a RADIUS server to store an administrator password.
You can configure a regular administrator with a fixed password in the RADIUS server if it can be supported. A regular administrator with a fixed password in the RADIUS server can perform both SSH and SCP with no additional authentication required.
Using an SCP-only administrator password.
Use the command, /cfg/sys/sshd/scpadm to bypass the checking of SecurID.
60 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
An SCP-only administrator’s password is typically used when SecurID is used. For example, it can be used in an automation program (in which the tokens of SecurID are not available) to back up (download) the switch configurations each day.
N OTE – The SCP-only administrator’s password must be different from the regular administrator’s password. If the two passwords are the same, the administrator using that password will not be allowed to log in as an SSH user because the switch will recognize him as the SCP-only administrator. The switch will only allow the administrator access to SCP commands.
End User Access Control
Alteon OS allows an administrator to define end user accounts that permit end users to perform operation tasks via the switch CLI commands. Once end user accounts are configured and enabled, the switch requires username/password authentication.
For example, an administrator can assign a user, who can then log into the switch and perform operational commands (effective only until the next switch reboot).
Considerations for Configuring End User Accounts
A maximum of 10 user IDs are supported on the switch.
Alteon OS supports end user support for Console, Telnet, BBI, and SSHv1/v2 access to the switch. As a result, only very limited access will be granted to the Primary Administrator under the BBI/SSH1 mode of access.
If RADIUS authentication is used, the user password on the Radius server will override the user password on the GbE Switch Module. Also note that the password change command on the switch only modifies the use switch password and has no effect on the user password on the Radius server. Radius authentication and user password cannot be used concurrently to access the switch.
Passwords can be up to 15 characters in length for TACACS, RADIUS, Telnet, SSH, Console, and Web access.
42C4911, January 2007 Chapter 1: Accessing the Switch 61
Alteon OS Application Guide
Strong Passwords
The administrator can require use of Strong Passwords for users to access the GbESM. Strong
Passwords enhance security because they make password guessing more difficult.
The following rules apply when Strong Passwords are enabled:
Each passwords must be 8 to 14 characters
Within the first 8 characters, the password:
must have at least one number or one symbol
must have both upper and lower case letters cannot be the same as any four previously used passwords
The following are examples of strong passwords:
1234AbcXyz
Super+User
Exo1cet2
The administrator can choose the number of days allowed before each password expires. When a strong password expires, the user is allowed to log in one last time (last time) to change the password. A warning provides advance notice for users to change the password.
Use the Strong Password menu to configure Strong Passwords.
>> # /cfg/sys/access/user /strongpw
User Access Control Menu
The end user access control menu is located in the System access menu.
>> # /cfg/sys/access/user
Setting up User IDs
Up to 10 user IDs can be configured in the User ID menu.
>> # /cfg/sys/access/user/uid 1
62 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
Defining User Names and Passwords
Use the User ID menu to define user names and passwords.
>> User ID 1 # name user1 (Assign name to user ID 1)
Current user name:
New user name: user1
>> User ID 1 # passwd (Assign password to user ID 1)
Changing user password; validation required:
Enter current admin password: <current administrator password>
Enter new user1 password: <new user password>
Re-enter new user1 password: <new user password>
New user1 password accepted.
Defining a User’s Access Level
The end user is by default assigned to the user access level (also known as class of service, or
CoS). CoS for all user accounts have global access to all resources except for User CoS, which
has access to view only resources that the user owns. For more information, see Table 1-2
“User Access Levels” on page 47
.
To change the user’s level, enter the class of service cos command, and select one of the following options:
>> User ID 1 # cos <user|oper|admin>
Validating a User’s Configuration
User ID 2 # cur
name jane , dis, cos user , password valid, offline
Enabling or Disabling a User
An end user account must be enabled before the switch recognizes and permits login under the account. Once enabled, the switch requires any user to enter both username and password.
>> # /cfg/sys/access/user/uid <#>/ena
>> # /cfg/sys/access/user/uid <#>/dis
42C4911, January 2007 Chapter 1: Accessing the Switch 63
Alteon OS Application Guide
Listing Current Users
The cur command displays defined user accounts and whether or not each user is currently logged into the switch.
# /cfg/sys/access/user/cur
Usernames:
user - Enabled - offline
oper - Disabled - offline
admin - Always Enabled - online 1 session
Current User ID table:
1: name jane , ena, cos user , password valid, online
2: name john , ena, cos user , password valid, online
Logging into an End User Account
Once an end user account is configured and enabled, the user can login to the switch username/ password combination. The level of switch access is determined by the CoS established for the end user account.
64 Chapter 1: Accessing the Switch 42C4911, January 2007
Alteon OS Application Guide
42C4911, January 2007 Chapter 1: Accessing the Switch 65
Alteon OS Application Guide
66 Chapter 1: Accessing the Switch 42C4911, January 2007
C HAPTER 2
Port-based Network Access Control
Port-Based Network Access control provides a means of authenticating and authorizing devices attached to a LAN port that has point-to-point connection characteristics. It prevents access to ports that fail authentication and authorization. This feature provides security to ports of the GbESM that connect to blade servers.
The following topics are discussed in this section:
“Extensible Authentication Protocol over LAN” on page 68
“802.1x Authentication Process” on page 69
“802.1x Port States” on page 71
“Supported RADIUS Attributes” on page 72
“Configuration Guidelines” on page 73
42C4911, January 2007 67
Alteon OS Application Guide
Extensible Authentication Protocol over LAN
Alteon OS can provide user-level security for its ports using the IEEE 802.1x protocol, which is a more secure alternative to other methods of port-based network access control. Any device attached to an 802.1x-enabled port that fails authentication is prevented access to the network and denied services offered through that port.
The 802.1x standard describes port-based network access control using Extensible Authentication Protocol over LAN (EAPoL). EAPoL provides a means of authenticating and authorizing devices attached to a LAN port that has point-to-point connection characteristics and of preventing access to that port in cases of authentication and authorization failures.
EAPoL is a client-server protocol that has the following components:
Supplicant or Client
The Supplicant is a device that requests network access and provides the required credentials (user name and password) to the Authenticator and the Authenticator Server.
Authenticator
The Authenticator enforces authentication and controls access to the network. The
Authenticator grants network access based on the information provided by the Supplicant and the response from the Authentication Server. The Authenticator acts as an intermediary between the Supplicant and the Authentication Server: requesting identity information from the client, forwarding that information to the Authentication Server for validation, relaying the server’s responses to the client, and authorizing network access based on the results of the authentication exchange. The GbESM acts as an Authenticator.
Authentication Server,
The Authentication Server validates the credentials provided by the Supplicant to determine if the Authenticator should grant access to the network. The Authentication Server may be co-located with the Authenticator. The GbESM relies on external RADIUS servers for authentication.
Upon a successful authentication of the client by the server, the 802.1x-controlled port transitions from unauthorized to authorized state, and the client is allowed full access to services through the port. When the client sends an EAP-Logoff message to the authenticator, the port will transition from authorized to unauthorized state.
68 Chapter 2: Port-based Network Access Control 42C4911, January 2007
Alteon OS Application Guide
802.1x Authentication Process
The clients and authenticators communicate using Extensible Authentication Protocol (EAP), which was originally designed to run over PPP, and for which the IEEE 802.1x Standard has defined an encapsulation method over Ethernet frames, called EAP over LAN (EAPOL).
Figure 2-1 shows a typical message exchange initiated by the client.
802.1x Client
RADIUS
Server
EAPOL
Ethernet
GbESM
(Authenticator)
(RADIUS Client)
RADIUS-EAP
UDP/IP
EAPOL-Start
Port Unauthorized
EAP-Request (Credentials)
EAP-Response (Credentials)
Radius-Access-Request
Radius-Access-Challenge
EAP-Request (Credentials)
EAP-Response (Credentials)
Radius-Access-Request
Radius-Access-Accept
EAP-Success
Port Authorized
Figure 2-1 Authenticating a Port Using EAPoL
42C4911, January 2007 Chapter 2: Port-based Network Access Control 69
Alteon OS Application Guide
EAPoL Message Exchange
During authentication, EAPOL messages are exchanged between the client and the GbESM authenticator, while RADIUS-EAP messages are exchanged between the GbESM authenticator and the RADIUS server.
Authentication is initiated by one of the following methods:
GbESM authenticator sends an EAP-Request/Identity packet to the client
Client sends an EAPOL-Start frame to the GbESM authenticator, which responds with an
EAP-Request/Identity frame.
The client confirms its identity by sending an EAP-Response/Identity frame to the GbESM authenticator, which forwards the frame encapsulated in a RADIUS packet to the server.
The RADIUS authentication server chooses an EAP-supported authentication algorithm to verify the client’s identity, and sends an EAP-Request packet to the client via the GbESM authenticator. The client then replies to the RADIUS server with an EAP-Response containing its credentials.
Upon a successful authentication of the client by the server, the 802.1x-controlled port transitions from unauthorized to authorized state, and the client is allowed full access to services through the controlled port. When the client later sends an EAPOL-Logoff message to the
GbESM authenticator, the port transitions from authorized to unauthorized state.
If a client that does not support 802.1x connects to an 802.1x-controlled port, the GbESM authenticator requests the client's identity when it detects a change in the operational state of the port. The client does not respond to the request, and the port remains in the unauthorized state.
N OTE – When an 802.1x-enabled client connects to a port that is not 802.1x-controlled, the client initiates the authentication process by sending an EAPOL-Start frame. When no response is received, the client retransmits the request for a fixed number of times. If no response is received, the client assumes the port is in authorized state, and begins sending frames, even if the port is unauthorized.
70 Chapter 2: Port-based Network Access Control 42C4911, January 2007
Alteon OS Application Guide
802.1x Port States
The state of the port determines whether the client is granted access to the network, as follows:
Unauthorized
While in this state the port discards all ingress and egress traffic except EAP packets.
Authorized
When the client is successfully authenticated, the port transitions to the authorized state allowing all traffic to and from the client to flow normally.
Force Unauthorized
You can configure this state that denies all access to the port.
Force Authorized
You can configure this state that allows full access to the port.
Use the 802.1x Global Configuration Menu (/cfg/l2/8021x/global) to configure 802.1x authentication for all ports in the switch. Use the 802.1x Port Menu
(/cfg/l2/8021x/port x) to configure a single port.
42C4911, January 2007 Chapter 2: Port-based Network Access Control 71
Alteon OS Application Guide
Supported RADIUS Attributes
The Alteon 802.1x Authenticator relies on external RADIUS servers for authentication with EAP.
Table 2 lists the RADIUS attributes that are supported as part of
RADIUS-EAP authentication based on the guidelines specified in Annex D of the 802.1x standard and RFC 3580.
Table 2 Support for RADIUS Attributes
#
1
4
5
Attribute
User-Name
NAS-IP-Address
NAS-Port
Attribute Value
The value of the Type-Data field from the supplicant’s
EAP-Response/Identity message. If the Identity is unknown (i.e. Type-Data field is zero bytes in length), this attribute will have the same value as the Calling-Station-
Id.
A-R A-A A-C A-R
1 0-1 0 0
1 0 0 0 IP address of the authenticator used for Radius communication.
Port number of the authenticator port to which the supplicant is attached.
1 0 0 0
24 State
30 Called-Station-ID
31 Calling-Station-ID
79 EAP-Message
Server-specific value. This is sent unmodified back to the server in an Access-Request that is in response to an
Access-Challenge.
0-1 0-1 0-1
1 0 0 The MAC address of the authenticator encoded as an
ASCII string in canonical format, e.g. 000D5622E3 9F.
The MAC address of the supplicant encoded as an ASCII string in canonical format, e.g. 00034B436206.
1 0 0
Encapsulated EAP packets from the supplicant to the authentication server (Radius) and vice-versa. The authenticator relays the decoded packet to both devices.
1+
0
0
0
1+ 1+ 1+
80 Message-Authenticator
Always present whenever an EAP-Message attribute is also included. Used to integrity-protect a packet.
1 1 1 1
87 NAS-Port-ID Name assigned to the authenticator port, e.g.
Server1_Port3
1 0 0
Legend:
RADIUS Packet Types: A-R (Access-Request), A-A (Access-Accept), A-C (Access-Challenge), A-R (Access-Reject)
RADIUS Attribute Support:
0 This attribute MUST NOT be present in a packet.
0+ Zero or more instances of this attribute MAY be present in a packet.
0-1 Zero or one instance of this attribute MAY be present in a packet.
1 Exactly one instance of this attribute MUST be present in a packet.
1+ One or more of these attributes MUST be present.
0
72 Chapter 2: Port-based Network Access Control 42C4911, January 2007
Alteon OS Application Guide
Configuration Guidelines
When configuring EAPoL, consider the following guidelines:
The 802.1x port-based authentication is currently supported only in point-to-point configurations, that is, with a single supplicant connected to an 802.1x-enabled switch port.
When 802.1x is enabled, a port has to be in the authorized state before any other Layer 2 feature can be operationally enabled. For example, the STG state of a port is operationally disabled while the port is in the unauthorized state.
The 802.1x supplicant capability is not supported. Therefore, none of its ports can successfully connect to an 802.1x-enabled port of another device, such as another switch, that acts as an authenticator, unless access control on the remote port is disabled or is configured in forced-authorized mode. For example, if a GbESM is connected to another
GbESM, and if 802.1x is enabled on both switches, the two connected ports must be configured in force-authorized mode.
The 802.1x standard has optional provisions for supporting dynamic virtual LAN assignment via RADIUS tunnelling attributes, for example, Tunnel-Type (=VLAN),
Tunnel-Medium-Type (=802), and Tunnel-Private-Group-ID (=VLAN id).
These attributes are not supported and might affect 802.1x operations. Other unsupported attributes include Service-Type, Session-Timeout, and Termination-Action.
RADIUS accounting service for 802.1x-authenticated devices or users is not supported.
Configuration changes performed using SNMP and the standard 802.1x MIB will take effect immediately.
42C4911, January 2007 Chapter 2: Port-based Network Access Control 73
Alteon OS Application Guide
74 Chapter 2: Port-based Network Access Control 42C4911, January 2007
C HAPTER 3
VLANs
This chapter describes network design and topology considerations for using Virtual Local Area
Networks (VLANs). VLANs are commonly used to split up groups of network users into manageable broadcast domains, to create logical segmentation of workgroups, and to enforce security policies among logical segments. The following topics are discussed in this chapter:
“VLANs and Port VLAN ID Numbers” on page 77
“VLAN Topologies and Design Considerations” on page 84
This section discusses how you can logically connect users and segments to a host that supports many logical segments or subnets by using the flexibility of the multiple VLAN system.
“Protocol-based VLANs” on page 87
N OTE – Basic VLANs can be configured during initial switch configuration (see “Using the
Setup Utility” in the Alteon OS Command Reference). More comprehensive VLAN configuration can be done from the Command Line Interface (see “VLAN Configuration” as well as
“Port Configuration” in the Alteon OS Command Reference).
42C4911, January 2007 75
Alteon OS Application Guide
Overview
Setting up virtual LANs (VLANs) is a way to segment networks to increase network flexibility without changing the physical network topology. With network segmentation, each switch port connects to a segment that is a single broadcast domain. When a switch port is configured to be a member of a VLAN, it is added to a group of ports (workgroup) that belong to one broadcast domain.
Ports are grouped into broadcast domains by assigning them to the same VLAN. Frames received in one VLAN can only be forwarded within that VLAN, and multicast, broadcast, and unknown unicast frames are flooded only to ports in the same VLAN. The GbE Switch
Module supports jumbo frames, up to 12288 bytes.
76 Chapter 3: VLANs 42C4911, January 2007
VLANs and Port VLAN ID Numbers
Alteon OS Application Guide
VLAN Numbers
Alteon OS supports up to 1024 VLANs per switch. Even though the maximum number of VLANs supported at any given time is 1024, each can be identified with any number between 1 and 4095. VLAN 1 is the default VLAN for the external ports and the internal blade ports. VLAN 4095 is reserved for use by the internal management ports (MGT1 and MGT2).
VLAN 4094 is reserved for use by the external management port (EXT7).
Viewing VLANs
VLAN information menu:
VLAN Name Status Ports
---- ------------------------ ------ -------------------------
1 Default VLAN ena INT1-INT14 EXT1-EXT6
2 VLAN 2 dis empty
4094 EXT-Mgmt VLAN ena EXT7
4095 Mgmt VLAN ena MGT1-MGT2
PVLAN Protocol FrameType EtherType Priority Status Ports
----- -------- -------------------- -------- ------ -----------
1 2 empty 0000 0 dis empty
PVLAN PVLAN-Tagged Ports
----- --------------------------none none
N OTE – The sample screens that appear in this document might differ slightly from the screens displayed by your system. Screen content varies based on the type of BladeCenter unit that you are using and the firmware versions and options that are installed.
PVID Numbers
Each port in the switch has a configurable default VLAN number, known as its PVID. By default, the PVID for all non-management ports is set to 1, which correlates to the default
VLAN ID. The PVID for each port can be configured to any VLAN number between 1 and
4094.
42C4911, January 2007 Chapter 3: VLANs 77
Alteon OS Application Guide
Viewing and Configuring PVIDs
Use the following CLI commands to view PVIDs:
Port information:
Alias Port Tag Fast PVID NAME VLAN(s)
----- ---- --- ---- ---- -------------- ----------------------------
---
INT1 1 n n 1 INT1 1
INT2 2 n n 1 INT2 1
INT3 3 n n 1 INT3 1
INT4 4 n n 1 INT4 1
INT5 5 n n 1 INT5 1
INT6 6 n n 1 INT6 1
INT7 7 n n 1 INT7 1
INT8 8 n n 1 INT8 1
INT9 9 n n 1 INT9 1
INT10 10 n n 1 INT10 1
INT11 11 n n 1 INT11 1
INT12 12 n n 1 INT12 1
INT13 13 n n 1 INT13 1
INT14 14 n n 1 INT14 1
MGT1 15 n n 4095 MGT1 4095
MGT2 16 n n 4095 MGT2 4095
EXT1 17 n n 1 EXT1 1
EXT2 18 n n 1 EXT2 1
EXT3 19 n n 1 EXT3 1
EXT4 20 n n 1 EXT4 1
EXT5 21 n n 1 EXT5 1
EXT6 22 n n 1 EXT6 1
EXT7 23 n n 4094 EXT7 4094
* = PVID is tagged.
N OTE – The sample screens that appear in this document might differ slightly from the screens displayed by your system. Screen content varies based on the type of BladeCenter unit that you are using and the firmware versions and options that are installed.
Port Configuration:
>> /cfg/port INT7/pvid 7
Current port VLAN ID: 1
New pending port VLAN ID: 7
>> Port INT7#
78 Chapter 3: VLANs 42C4911, January 2007
Alteon OS Application Guide
Each port on the switch can belong to one or more VLANs, and each VLAN can have any number of switch ports in its membership. Any port that belongs to multiple VLANs, however,
must have VLAN tagging enabled (see “VLAN Tagging” on page 80
).
42C4911, January 2007 Chapter 3: VLANs 79
Alteon OS Application Guide
VLAN Tagging
Alteon OS software supports 802.1Q VLAN tagging, providing standards-based VLAN support for Ethernet systems.
Tagging places the VLAN identifier in the frame header of a packet, allowing each port to belong to multiple VLANs. When you add a port to multiple VLANs, you also must enable tagging on that port.
Since tagging fundamentally changes the format of frames transmitted on a tagged port, you must carefully plan network designs to prevent tagged frames from being transmitted to devices that do not support 802.1Q VLAN tags, or devices where tagging is not enabled.
Important terms used with the 802.1Q tagging feature are:
VLAN identifier (VID)—the 12-bit portion of the VLAN tag in the frame header that identifies an explicit VLAN.
Port VLAN identifier (PVID)—a classification mechanism that associates a port with a specific VLAN. For example, a port with a PVID of 3 (PVID =3) assigns all untagged frames received on this port to VLAN 3. Any untagged frames received by the switch are classified with the PVID of the receiving port.
Tagged frame—a frame that carries VLAN tagging information in the header. This VLAN tagging information is a 32-bit field (VLAN tag) in the frame header that identifies the frame as belonging to a specific VLAN. Untagged frames are marked (tagged) with this classification as they leave the switch through a port that is configured as a tagged port.
Untagged frame— a frame that does not carry any VLAN tagging information in the frame header.
Untagged member—a port that has been configured as an untagged member of a specific
VLAN. When an untagged frame exits the switch through an untagged member port, the frame header remains unchanged. When a tagged frame exits the switch through an untagged member port, the tag is stripped and the tagged frame is changed to an untagged frame.
Tagged member—a port that has been configured as a tagged member of a specific
VLAN. When an untagged frame exits the switch through a tagged member port, the frame header is modified to include the 32-bit tag associated with the PVID. When a tagged frame exits the switch through a tagged member port, the frame header remains unchanged (original VID remains).
N OTE – If a 802.1Q tagged frame is received by a port that has VLAN-tagging disabled, then the frame is dropped at the ingress port.
80 Chapter 3: VLANs 42C4911, January 2007
Alteon OS Application Guide
Figure 3-1 Default VLAN settings
802.1Q Switch
VLAN 1
PVID = 1
Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 ...
DA
SA
Incoming untagged packet
Data
CRC
CRC
Outgoing untagged packet
(unchanged)
Data
SA
DA
Key
By default:
All ports are assigned PVID = 1
All external ports are untagged members of VLAN 1
All internal server ports are untagged members of VLAN 1
BS45010A
N OTE – The port numbers specified in these illustrations may not directly correspond to the physical port configuration of your switch model.
When a VLAN is configured, ports are added as members of the VLAN, and the ports are
defined as either tagged or untagged (see Figure 3-2
In Figure 3-1 , untagged incoming packets are assigned directly to VLAN 2 (PVID = 2). Port 5
is configured as a tagged member of VLAN 2, and port 7 is configured as an untagged member of VLAN 2.
The default configuration settings for GbE Switch Modules have all ports set as untagged members of VLAN 1 with all ports configured as PVID = 1. In the default configuration exam-
ple shown in Figure 3-1 on page 81 , all incoming packets are assigned to VLAN 1 by the
default port VLAN identifier (PVID =1).
through Figure 3-5 illustrate generic examples of VLAN tagging.
42C4911, January 2007 Chapter 3: VLANs 81
Alteon OS Application Guide
N OTE – The port assignments in the following figures are not meant to match the
GbE Switch Module.
Figure 3-2 Port-based VLAN assignment
PVID = 2
Untagged packet
CRC Data SA DA
Port 1 Port 2 Port 3
802.1Q Switch
Tagged member of VLAN 2
B efore
Port 6 Port 7 Port 8
Untagged member of VLAN 2
BS45011A
As shown in Figure 3-3 , the untagged packet is marked (tagged) as it leaves the switch through
port 5, which is configured as a tagged member of VLAN 2. The untagged packet remains unchanged as it leaves the switch through port 7, which is configured as an untagged member of VLAN 2.
PVID = 2
Figure 3-3 802.1Q tagging (after port-based VLAN assignment)
Port 1 Port 2 Port 3
Tagged member of VLAN 2
802.1Q Switch CRC* Data Tag SA DA
(*Recalculated)
Port 6 Port 7 Port 8
Untagged memeber of VLAN 2
CRC
Data
Outgoing untagged packet
(unchanged)
SA
DA
8100 Priority CFI VID = 2
16 bits 3 bits 1 bits 12 bits
After
Key
Priority
CFI
VID
- User_priority
- Canonical format indicator
- VLAN identifier
BS45012A
82 Chapter 3: VLANs 42C4911, January 2007
Alteon OS Application Guide
, tagged incoming packets are assigned directly to VLAN 2 because of the tag assignment in the packet. Port 5 is configured as a tagged member of VLAN 2, and port 7 is configured as an untagged member of VLAN 2.
Figure 3-4 802.1Q tag assignment
PVID = 2
Tagged packet
CRC Data Tag SA DA
Port 1 Port 2 Port 3
802.1Q Switch
Tagged member of VLAN 2
B efore
Port 6 Port 7 Port 8
Untagged member of VLAN 2
BS45013A
As shown in
Figure 3-5 , the tagged packet remains unchanged as it leaves the switch through
port 5, which is configured as a tagged member of VLAN 2. However, the tagged packet is stripped (untagged) as it leaves the switch through port 7, which is configured as an untagged member of VLAN 2.
Figure 3-5 802.1Q tagging (after 802.1Q tag assignment)
PVID = 2
Port 1 Port 2 Port 3
Tagged member of VLAN 2
802.1Q Switch CRC Data Tag SA DA
Port 6 Port 7 Port 8
Untagged member of VLAN 2
CRC* (*Recalculated)
8100 Priority CFI VID = 2
16 bits 3 bits 1 bit 12 bits
Data
SA
DA
Outgoing untagged packet changed
(tag removed)
After
Key
Priority
CFI
VID
- User_priority
- Canonical format indicator
- VLAN identifier
BS45014A
N OTE – Set the configuration to factory default (/boot/conf factory) to reset all nonmanagement ports to VLAN 1.
42C4911, January 2007 Chapter 3: VLANs 83
Alteon OS Application Guide
VLAN Topologies and Design Considerations
By default, the Alteon OS software is configured so that tagging is disabled on all external ports and all internal ports.
By default, the Alteon OS software is configured so that all internal ports are members of
VLAN 1.
By default, the Alteon OS software is configured so that the management ports (MGT1 and MGT2) are members of the management VLAN 4095.
By default, the Alteon OS software is configured so that the external management port
(EXT7) is a member of VLAN 4094.
If configuring Spanning Tree Groups (STG), note that Spanning Tree Groups 2-128 may contain only one VLAN.
VLAN configuration rules
VLANs operate according to specific configuration rules. When creating VLANs, consider the following rules that determine how the configured VLAN reacts in any network topology:
All ports involved in trunking and port mirroring must have the same VLAN configuration. If a port is on a trunk with a mirroring port, the VLAN configuration cannot be changed. For more information trunk groups, see
“Port Trunking Example” on page 97 .
All ports that are involved in port mirroring must have memberships in the same VLANs.
If a port is configured for port mirroring, the port’s VLAN membership cannot be
changed. For more information on configuring port mirroring, see “Monitoring Ports” on page 246 .
84 Chapter 3: VLANs 42C4911, January 2007
Alteon OS Application Guide
Example 1: Multiple VLANs with Tagging Adapters
BladeCenter
VLAN #3 VLAN #1, 2, 3
Figure 3-6 Example 1: Multiple VLANs with VLAN-Tagged Gigabit Adapters
The features of this VLAN are described below:
Component
GbE Switch
Module
Server #1
Server #2
Description
This switch is configured for three VLANs that represent three different IP subnets. Two servers and five clients are attached to the switch.
This server is a member of VLAN 3 and has presence in only one IP subnet. The associated internal switch port is only a member of VLAN
3, so tagging is disabled.
This high-use server needs to be accessed from all VLANs and IP subnets. The server has a VLAN-tagging adapter installed with VLAN tagging turned on. The adapter is attached to one of the internal switch ports, that is a member of VLANs 1, 2, and 3, and has tagging enabled.
Because of the VLAN tagging capabilities of both the adapter and the switch, the server is able to communicate on all three IP subnets in this network. Broadcast separation between all three VLANs and subnets, however, is maintained.
42C4911, January 2007 Chapter 3: VLANs 85
Alteon OS Application Guide
Component
PCs #1 and #2
PC #3
PC #4
PC #5
Description
These PCs are attached to a shared media hub that is then connected to the switch. They belong to VLAN 2 and are logically in the same IP subnet as Server 2 and PC 5. The associated external switch port has tagging disabled.
A member of VLAN 1, this PC can only communicate with Server 2 and PC 5. The associated external switch port has tagging disabled.
A member of VLAN 3, this PC can only communicate with Server 1 and Server 2. The associated external switch port has tagging disabled.
A member of both VLAN 1 and VLAN 2, this PC has a VLAN-tagging
Gigabit Ethernet adapter installed. It can communicate with Server 2 and PC 3 via VLAN 1, and to Server 2, PC 1 and PC 2 via VLAN 2.
The associated external switch port is a member of VLAN 1 and
VLAN 2, and has tagging enabled.
N OTE – VLAN tagging is required only on ports that are connected to other GbE Switch
Modules or on ports that connect to tag-capable end-stations, such as servers with VLANtagging adapters.
86 Chapter 3: VLANs 42C4911, January 2007
Alteon OS Application Guide
Protocol-based VLANs
Protocol-based VLANs (PVLANs) allow you to segment network traffic according to the network protocols in use. Traffic generated by supported network protocols can be confined to a particular port-based VLAN. You can give different priority levels to traffic generated by different network protocols.
With PVLAN, the switch classifies incoming packets by Ethernet protocol of the packets, not by the configuration of the ingress port. When an untagged or priority-tagged frame arrives at an ingress port, the protocol information carried in the frame is used to determine a VLAN to which the frame belongs. If a frame’s protocol is not recognized as a pre-defined PVLAN type, the ingress port’s PVID is assigned to the frame. When a tagged frame arrives, the VLAN ID in the frame’s tag is used.
Each VLAN can contain up to eight different PVLANs. You can configure separate PVLANs on different VLANs, with each PVLAN segmenting traffic for the same protocol type. For example, you can configure PVLAN 1 on VLAN 2 to segment IPv4 traffic, and PVLAN 8 on
VLAN 100 to segment IPv4 traffic.
To define a PVLAN on a VLAN, configure a PVLAN number (1-8) and specify the frame type and the Ethernet type of the PVLAN protocol. You must assign at least one port to the PVLAN before it can function. Define the PVLAN frame type and Ethernet type as follows:
Frame type—consists of one of the following values:
Ether2 (Ethernet II)
SNAP (Simple Network Access Protocol)
LLC (Logical Link Control)
Ethernet type—consists of a 4-digit (16 bit) hex value that defines the Ethernet type. You can use common Ethernet protocol values, or define your own values. Following are examples of common Ethernet protocol values:
IPv4 = 0080
IPv6 = 86dd
ARP = 0806
42C4911, January 2007 Chapter 3: VLANs 87
Alteon OS Application Guide
Port-based vs. Protocol-based VLANs
Each VLAN supports both port-based and protocol-based association, as follows:
The default VLAN configuration is port-based. All data ports are members of VLAN 1, with no PVLAN association.
When you add ports to a PVLAN, the ports become members of both the port-based
VLAN and the PVLAN. For example, if you add port EXT1 to PVLAN 1 on VLAN 2, the port also becomes a member of VLAN 2.
When you delete a PVLAN, it’s member ports remain members of the port-based VLAN.
For example, if you delete PVLAN 1 from VLAN 2, port EXT1 remains a member of
VLAN 2.
When you delete a port from a VLAN, the port is deleted from all corresponding
PVLANs.
PVLAN Priority Levels
You can assign each PVLAN a priority value of 0-7, used for Quality of Service (QoS).
PVLAN priority takes precedence over a port’s configured priority level. If no priority level is configured for the PVLAN (priority = 0), each port’s priority is used (if configured).
All member ports of a PVLAN have the same PVLAN priority level.
PVLAN Tagging
When PVLAN tagging is enabled, the switch tags frames that match the PVLAN protocol. For
more information about tagging, see “VLAN Tagging” on page 80 .
Untagged ports must have PVLAN tagging disabled. Tagged ports can have PVLAN tagging either enabled or disabled.
PVLAN tagging has higher precedence than port-based tagging. If a port is tag enabled
(/cfg/port x/tag), and the port is a member of a PVLAN, the PVLAN tags egress frames that match the PVLAN protocol.
Use the tag list command (/cfg/l2/vlan x/pvlan x/taglist) to define the complete list of tag-enabled ports in the PVLAN. Note that all ports not included in the PVLAN tag list will have PVLAN tagging disabled.
88 Chapter 3: VLANs 42C4911, January 2007
Alteon OS Application Guide
PVLAN Configuration Guidelines
Consider the following guidelines when you configure protocol-based VLANs:
Each port can support up to 16 VLAN protocols.
The GbESM can support up to 16 protocols simultaneously.
Each PVLAN must have at least one port assigned before it can be activated.
The same port within a port-based VLAN can belong to multiple PVLANs.
An untagged port can be a member of multiple PVLANs.
A port cannot be a member of different VLANs with the same protocol association.
Configuring PVLAN
Follow this procedure to configure a Protocol-based VLAN (PVLAN).
1.
Create a VLAN and define the protocol type(s) supported by the VLAN.
>> /cfg/l2/vlan 2
>> VLAN 2# ena
Current status: disabled
New status: enabled
(Select VLAN 2)
>> VLAN 2# pvlan
Enter protocol number [1-8]:1
>> VLAN 2 Protocol 1# pty
(Select a protocol number)
Current FrameType: empty; EtherType: empty
Enter new frame type(Ether2/SNAP/LLC): ether2 (Define the frame type)
Enter new Ether type: 0800 (Define the Ethernet type)
New pending FrameType: Ether2; EtherType: 0800
2.
Configure the priority value for the protocol.
>> VLAN 2 Protocol 1# prio
Current protocol priority: 0
Enter new protocol priority [0-7]: 1
(Configure the priority value)
42C4911, January 2007 Chapter 3: VLANs 89
Alteon OS Application Guide
3.
Add member ports for this PVLAN.
>> VLAN 2 Protocol 1# add int1
Port INT1 is an UNTAGGED port and its current PVID is 1.
Confirm changing PVID from 1 to 2 [y/n]: y
Current ports for VLAN 2: empty
Current ports for VLAN 1, Protocol 3: empty
Pending new ports for VLAN 2: INT1
Pending new ports for VLAN 2, Protocol 1: INT1
>> VLAN 2 Protocol 1# add ext1
Port EXT1 is an UNTAGGED port and its current PVID is 1.
Confirm changing PVID from 1 to 2 [y/n]: y
Current ports for VLAN 2: empty
Current ports for VLAN 1, Protocol 2: empty
Pending new ports for VLAN 2: INT1 EXT1
Pending new ports for VLAN 2, Protocol 1: INT1 EXT1
4.
Configure VLAN tagging for ports.
>> VLAN 2 Protocol 1# /cfg/port int1/tag ena (Enable tagging on port)
Current VLAN tag support: disabled
New VLAN tag support: enabled
Port INT1 changed to tagged.
>> Port INT1# /cfg/l2/vlan 2/pvlan 1/tagpvl (Enable PVLAN tagging)
Enter port to be tagged: int1
Ena/Dis pvlan tag: ena
Current status: disabled
New status: enabled
WARN: Tagging status of Port 1 in VLAN 2 will be changed for
all protocols.
Confirm changing port's pvlan tagging status [y/n]: y
5.
Enable the PVLAN.
>> VLAN 2 Protocol 1# ena
Current status: disabled
New status: enabled
>> VLAN 2 Protocol 1# apply
>> VLAN 2 Protocol 1# save
(Enable the protocol-based VLAN)
(Apply the configuration)
(Save your changes)
90 Chapter 3: VLANs 42C4911, January 2007
Alteon OS Application Guide
6.
Verify PVLAN operation.
>> /info/l2/vlan (View VLAN information)
VLAN Name Status Ports
---- ------------------------ ------ -------------------------
1 Default VLAN ena INT1-INT14 EXT2-EXT6
2 VLAN 2 ena INT1 EXT1
4094 EXT-Mgmt VLAN ena EXT7
4095 Mgmt VLAN ena MGT1 MGT2
PVLAN Protocol FrameType EtherType Priority Status Ports
----- -------- -------------------- -------- ------ -----------
2 1 Ether2 0800 0 ena INT1
PVLAN PVLAN-Tagged Ports
----- ---------------------------
2 INT1 INT2
42C4911, January 2007 Chapter 3: VLANs 91
Alteon OS Application Guide
92 Chapter 3: VLANs 42C4911, January 2007
C HAPTER 4
Ports and Trunking
Trunk groups can provide super-bandwidth, multi-link connections between GbE Switch Modules or other trunk-capable devices. A trunk group is a group of ports that act together, combining their bandwidth to create a single, larger virtual link. This chapter provides configuration background and examples for trunking multiple ports together:
“
” on this page
“Port Trunking Example” on page 97
“Configurable Trunk Hash Algorithm” on page 100
“Link Aggregation Control Protocol” on page 101
42C4911, January 2007 93
Alteon OS Application Guide
Overview
When using port trunk groups between two switches, as shown in Figure 4-1
, you can create a virtual link between the switches, operating up to 60Gb per second, depending on how many physical ports are combined. Each GbESM supports up to 13 trunk groups, and each trunk group can contain up to six member ports.
BladeCenter
Aggregate port trunk
Alteon Application Switch
Figure 4-1 Port Trunk Group
Trunk groups are also useful for connecting a GbE Switch Module to third-party devices that support link aggregation, such as Cisco routers and switches with EtherChannel technology
(not ISL trunking technology) and Sun's Quad Fast Ethernet Adapter. Trunk Group technology is compatible with these devices when they are configured manually.
94 Chapter 4: Ports and Trunking 42C4911, January 2007
Alteon OS Application Guide
Statistical Load Distribution
Network traffic is statistically distributed between the ports in a trunk group. The Alteon OSpowered switch uses the Layer 2 MAC address information present in each transmitted frame for determining load distribution.
Each packet’s particular combination of source and destination MAC addresses results in selecting one line in the trunk group for data transmission. If there are enough Layer 2 devices feeding the trunk lines, then traffic distribution becomes relatively even.
Built-In Fault Tolerance
Since each trunk group is comprised of multiple physical links, the trunk group is inherently fault tolerant. As long as one connection between the switches is available, the trunk remains active.
Statistical load balancing is maintained whenever a port in a trunk group is lost or returned to service.
Before you configure static trunks
When you create and enable a static trunk, the trunk members (switch ports) take on certain settings necessary for correct operation of the trunking feature.
Before you configure your trunk, you must consider these settings, along with specific configuration rules, as follows:
1.
Read the configuration rules provided in the section, “Trunk group configuration rules” on page 96
.”
2.
Determine which switch ports (up to six) are to become trunk members (the specific ports making up the trunk).
Ensure that the chosen switch ports are set to enabled, using the /cfg/port command.
Trunk member ports must have the same VLAN configuration.
3.
Consider how the existing Spanning Tree will react to the new trunk configuration. See
Chapter 5, “Spanning Tree Group ” for Spanning Tree Group configuration guidelines.
4.
Consider how existing VLANs will be affected by the addition of a trunk.
42C4911, January 2007 Chapter 4: Ports and Trunking 95
Alteon OS Application Guide
Trunk group configuration rules
The trunking feature operates according to specific configuration rules. When creating trunks, consider the following rules that determine how a trunk group reacts in any network topology:
All trunks must originate from one device, and lead to one destination device. For example, you cannot combine a link from Server 1 and a link from Server 2, into one trunk group.
Any physical switch port can belong to only one trunk group.
Trunking from third-party devices must comply with Cisco ® EtherChannel ® technology.
All trunk member ports must be assigned to the same VLAN configuration before the trunk can be enabled.
If you change the VLAN settings of any trunk member, you cannot apply the change until you change the VLAN settings of all trunk members.
When an active port is configured in a trunk, the port becomes a trunk member when you enable the trunk using the /cfg/l2/trunk/ena command. The Spanning Tree parameters for the port then change to reflect the new trunk settings.
All trunk members must be in the same Spanning Tree Group (STG) and can belong to only one Spanning Tree Group (STG). However if all ports are tagged, then all trunk ports can belong to multiple STGs.
If you change the Spanning Tree participation of any trunk member to enabled or disabled , the Spanning Tree participation of all members of that trunk changes similarly.
When a trunk is enabled, the trunk Spanning Tree participation setting takes precedence over that of any trunk member.
You cannot configure a trunk member as a monitor port in a port-mirroring configuration.
Trunks cannot be monitored by a monitor port; however, trunk members can be monitored.
To guarantee proper trunking behavior, all ports in static trunks must be configured for full-duplex mode (cfg/port x/gig/mode full).
96 Chapter 4: Ports and Trunking 42C4911, January 2007
Alteon OS Application Guide
Port Trunking Example
In the example below, three ports are trunked between two switches.
Alteon Application Switch
Trunk 3: Ports 2, 12, and 22
GbE Switch
Module
Trunk 1: Ports EXT1, EXT2, and EXT3
BladeCenter
Figure 4-2 Port Trunk Group Configuration Example
Prior to configuring each switch in the above example, you must connect to the appropriate switch’s Command Line Interface (CLI) as the administrator.
N OTE – For details about accessing and using any of the menu commands described in this example, see the Alteon OS C ommand Reference.
42C4911, January 2007 Chapter 4: Ports and Trunking 97
Alteon OS Application Guide
1.
Connect the switch ports that will be members in the trunk group.
2.
Follow these steps on the GbESM:
(a) Define a trunk group.
>> # /cfg/l2/trunk 1
>> Trunk group 1# add EXT1
>> Trunk group 1# add EXT2
>> Trunk group 1# add EXT3
>> Trunk group 1# ena
(Select trunk group 1)
(Add port EXT1 to trunk group 1)
(Add port EXT2 to trunk group 1)
(Add port EXT3 to trunk group 1)
(Enable trunk group 1)
(b)Apply and verify the configuration.
>> Trunk group 1# apply
>> Trunk group 1# cur
(Make your changes active)
(View current trunking configuration)
Examine the resulting information. If any settings are incorrect, make appropriate changes.
(c) Save your new configuration changes.
>> Trunk group 1# save (Save for restore after reboot)
3.
Repeat the process on the other switch.
>> # /cfg/l2/trunk 3
>> Trunk group 3# add 2
>> Trunk group 3# add 12
>> Trunk group 3# add 22
>> Trunk group 3# ena
>> Trunk group 3# apply
>> Trunk group 3# cur
>> Trunk group 3# save
(Select trunk group 3)
(Add port 2 to trunk group 3)
(Add port 12 to trunk group 3)
(Add port 22 to trunk group 3)
(Enable trunk group 3)
(Make your changes active)
(View current trunking configuration)
(Save for restore after reboot)
Trunk group 1 (on the GbESM) is now connected to trunk group 3 (on Alteon Application
Switch).
N OTE – In this example, a GbE Switch Module and an application switch are used. If a thirdparty device supporting link aggregation is used (such as Cisco routers and switches with
EtherChannel technology or Sun's Quad Fast Ethernet Adapter), trunk groups on the thirdparty device should be configured manually. Connection problems could arise when using automatic trunk group negotiation on the third-party device.
98 Chapter 4: Ports and Trunking 42C4911, January 2007
Alteon OS Application Guide
4.
Examine the trunking information on each switch.
>> /info/l2/trunk (View trunking information)
Information about each port in each configured trunk group is displayed. Make sure that trunk groups consist of the expected ports and that each port is in the expected state.
The following restrictions apply:
Any physical switch port can belong to only one trunk group.
Up to six ports can belong to the same trunk group.
Best performance is achieved when all ports in any given trunk group are configured for the same speed.
Trunking from third-party devices must comply with Cisco
®
EtherChannel
®
technology.
42C4911, January 2007 Chapter 4: Ports and Trunking 99
Alteon OS Application Guide
Configurable Trunk Hash Algorithm
This feature allows you to configure the particular parameters for the GbESM Trunk Hash algorithm instead of having to utilize the defaults. You can configure new default behavior for
Layer 2 traffic and Layer 3 traffic using the CLI menu cfg/l2/thash. You can select a minimum of one or a maximum of two parameters to create one of the following configurations:
Source IP (SIP)
Destination IP (DIP)
Source MAC (SMAC)
Destination MAC (DMAC)
Source IP (SIP) + Destination IP (DIP)
Source MAC (SMAC) + Destination MAC (DMAC)
100 Chapter 4: Ports and Trunking 42C4911, January 2007
Alteon OS Application Guide
Link Aggregation Control Protocol
Link Aggregation Control Protocol (LACP) is an IEEE 802.3ad standard for grouping several physical ports into one logical port (known as a dynamic trunk group or Link Aggregation group) with any device that supports the standard. Please refer to IEEE 802.3ad-2002 for a full description of the standard.
The 802.3ad standard allows standard Ethernet links to form a single Layer 2 link using the
Link Aggregation Control Protocol (LACP). Link aggregation is a method of grouping physical link segments of the same media type and speed in full duplex, and treating them as if they were part of a single, logical link segment. If a link in a LACP trunk group fails, traffic is reassigned dynamically to the remaining link/s of the dynamic trunk group.
N OTE – LACP implementation in Alteon OS does not support the Churn machine, an option used to detect if the port is operable within a bounded time period between the actor and the partner. Only the Market Responder is implemented, and there is no marker protocol generator.
A port’s Link Aggregation Identifier (LAG ID) determines how the port can be aggregated.
The Link Aggregation ID (LAG ID) is constructed mainly from the system ID and the port’s
admin key, as follows:
System ID is an integer value based on the switch’s MAC address and the system priority assigned in the CLI.
Admin key
A port’s Admin key is an integer value (1 - 65535) that you can configure in the CLI. Each
GbESM port that participates in the same LACP trunk group must have the same admin key value. The Admin key is local significant, which means the partner switch does not need to use the same Admin key value.
For example, consider two switches, an Actor (the GbESM) and a Partner (another switch), as
.
Table 4-1 Actor vs. Partner LACP configuration
Actor Switch
Port EXT1 (admin key = 100)
Port EXT2 (admin key = 100)
Partner Switch 1
Port 1 (admin key = 50)
Port 2 (admin key = 50)
Partner Switch 2
In the configuration shown in Table 4-1 , Actor switch ports EXT1 and EXT2 aggregate to
form an LACP trunk group with Partner switch ports 1 and 2.
42C4911, January 2007 Chapter 4: Ports and Trunking 101
Alteon OS Application Guide
LACP automatically determines which member links can be aggregated and then aggregates them. It provides for the controlled addition and removal of physical links for the link aggregation.
Each port in the GbESM can have one of the following LACP modes.
off (default)
The user can configure this port in to a regular static trunk group.
active
The port is capable of forming an LACP trunk. This port sends LACPDU packets to partner system ports.
passive
The port is capable of forming an LACP trunk. This port only responds to the LACPDU packets sent from an LACP active port.
Each active LACP port transmits LACP data units (LACPDUs), while each passive LACP port listens for LACPDUs. During LACP negotiation, the admin key is exchanged. The LACP trunk group is enabled as long as the information matches at both ends of the link. If the admin key value changes for a port at either end of the link, that port’s association with the LACP trunk group is lost.
When the system is initialized, all ports by default are in LACP off mode and are assigned unique admin keys. To make a group of ports aggregatable, you assign them all the same
admin key. You must set the port’s LACP mode to active to activate LACP negotiation. You can set other port’s LACP mode to passive, to reduce the amount of LACPDU traffic at the initial trunk-forming stage.
Use the /info/l2/trunk command or the /info/l2/lacp/dump command to check whether the ports are trunked.
N OTE – If you configure LACP on ports with 802.1x network access control, make sure the ports on both sides of the connection are properly configured for both LACP and 802.1x.
102 Chapter 4: Ports and Trunking 42C4911, January 2007
Alteon OS Application Guide
Configuring LACP
Use the following procedure to configure LACP for port EXT1 and port EXT2 to participate in link aggregation.
1.
Set the LACP mode on port EXT1.
>> # /cfg/l2/lacp/port EXT1
>> LACP port EXT1# mode active
(Select port EXT1)
(Set port EXT1 to LACP active mode)
2.
Define the admin key on port EXT1. Only ports with the same admin key can form a
LACP trunk group.
(Set port EXT1 adminkey to 100) >> LACP port EXT1# adminkey 100
Current LACP port adminkey: 17
New pending LACP port adminkey: 100
3.
Set the LACP mode on port EXT2.
>> # /cfg/l2/lacp/port EXT2
>> LACP port EXT2# mode active
(Select port EXT2)
(Set port EXT2 to LACP active mode)
4.
Define the admin key on port EXT2.
>> LACP port EXT2# adminkey 100
Current LACP port adminkey: 18
New pending LACP port adminkey: 100
5.
Apply and verify the configuration.
>> LACP port EXT2# apply
>> LACP port EXT2# cur
(Set port EXT2 adminkey to 100)
(Make your changes active)
(View current trunking configuration)
6.
Save your new configuration changes.
>> LACP port EXT2# save (Save for restore after reboot)
42C4911, January 2007 Chapter 4: Ports and Trunking 103
Alteon OS Application Guide
104 Chapter 4: Ports and Trunking 42C4911, January 2007
C HAPTER 5
Spanning Tree Group
When multiple paths exist on a network, Spanning Tree Group (STG) configures the network so that a switch uses only the most efficient path. The following topics are discussed in this chapter:
“Bridge Protocol Data Units (BPDUs)” on page 107
“Multiple Spanning Trees” on page 110
“Port Fast Forwarding” on page 115
“Fast Uplink Convergence” on page 116
42C4911, January 2007 105
Alteon OS Application Guide
Overview
Spanning Tree Group (STG) detects and eliminates logical loops in a bridged or switched network. When multiple paths exist, Spanning Tree configures the network so that a switch uses only the most efficient path. If that path fails, Spanning Tree automatically sets up another active path on the network to sustain network operations.
GbESM supports IEEE 802.1d Spanning Tree Protocol. It is compatible with PVST+ by configuring each STP Group in different STP instances.
N OTE – The GbESM also supports IEEE 802.1w Rapid Spanning Tree Protocol, and
IEEE 802.1s Multiple Spanning Tree Protocol. For more information, see Chapter 6,
“Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol.”
The relationship between port, trunk groups, VLANs, and Spanning Trees is shown in
Table 5-1 Ports, Trunk Groups, and VLANs
Switch Element
Port
Trunk group
VLAN (non-default)
Belongs to
Trunk group or
One or more VLANs
One or more VLANs
One Spanning Tree group
N OTE – Due to Spanning Tree’s sequence of listening, learning, and forwarding or blocking, lengthy delays may occur.
You can use Port Fast Forwarding (/cfg/port x/fastfwd/ena) to permit a port that participates in Spanning Tree to bypass the Listening and Learning states and enter directly into the Forwarding state. While in the Forwarding state, the port listens to the BPDUs to learn if there is a loop and, if dictated by normal STG behavior (following priorities, and so on), the port transitions into the Blocking state. This feature permits the GbE Switch Module to interoperate well within Rapid Spanning Tree networks.
106 Chapter 5: Spanning Tree Group 42C4911, January 2007
Alteon OS Application Guide
Bridge Protocol Data Units (BPDUs)
To create a Spanning Tree, the switch generates a configuration Bridge Protocol Data Unit
(BPDU), which it then forwards out of its ports. All switches in the Layer 2 network participating in the Spanning Tree gather information about other switches in the network through an exchange of BPDUs.
A BPDU is a 64-byte packet that is sent out at a configurable interval, which is typically set for two seconds. The BPDU is used to establish a path, much like a “hello” packet in IP routing.
BPDUs contain information about the transmitting bridge and its ports, including bridge and
MAC addresses, bridge priority, port priority, and path cost. If the ports are tagged, each port sends out a special BPDU containing the tagged information.
The generic action of a switch on receiving a BPDU is to compare the received BPDU to its own BPDU that it will transmit. If the received BPDU is better than its own BPDU, it will replace its BPDU with the received BPDU. Then, the switch adds its own bridge ID number and increments the path cost of the BPDU. The switch uses this information to block any necessary ports.
Determining the Path for Forwarding BPDUs
When determining which port to use for forwarding and which port to block, the GbE Switch
Module uses information in the BPDU, including each bridge priority ID. A technique based on the “lowest root cost” is then computed to determine the most efficient path for forwarding.
Bridge Priority
The bridge priority parameter controls which bridge on the network is the STG root bridge. To make one switch the root bridge, configure the bridge priority lower than all other switches and bridges on your network. The lower the value, the higher the bridge priority. Use the following command to configure the bridge priority:
/cfg/l2/stg x/brg/prio
Port Priority
The port priority helps determine which bridge port becomes the designated port. In a network topology that has multiple bridge ports connected to a single segment, the port with the lowest port priority becomes the designated port for the segment. Use the following command to configure the port priority:
/cfg/l2/stg x/port x/prio
42C4911, January 2007 Chapter 5: Spanning Tree Group 107
Alteon OS Application Guide
Port Path Cost
The port path cost assigns lower values to high-bandwidth ports, such as Gigabit Ethernet, to encourage their use. The cost of a port also depends on whether the port operates at full-duplex
(lower cost) or half-duplex (higher cost). For example, if a 100-Mbps (Fast Ethernet) link has a
“cost” of 10 in half-duplex mode, it will have a cost of 5 in full-duplex mode. The objective is to use the fastest links so that the route with the lowest cost is chosen. A value of 0 indicates that the default cost will be computed for an auto-negotiated link speed.
Spanning Tree Group configuration guidelines
This section provides important information on configuring Spanning Tree Groups (STGs):
Adding a VLAN to a Spanning Tree Group
If no VLANs exist beyond the default VLAN 1 see
for information on adding ports to VLANs.
Add the VLAN to the STG using the /cfg/l2/stg <stg-#>/add <vlan-number> command.
N OTE – To ensure proper operation with switches that use Cisco Per VLAN Spanning
Tree (PVST+), you must either create a separate STG for each VLAN, or manually add all associated VLANs into a single STG.
Creating a VLAN
When you create a VLAN, that VLAN automatically belongs to STG 1, the default STG. If you want the VLAN in another STG, you must move the VLAN by assigning it to another STG.
Move a newly created VLAN to an existing STG by following this order:
Create the VLAN
Add the VLAN to an existing STG
VLANs must be contained within a single STG; a VLAN cannot span multiple STGs. By confining VLANs within a single STG, you avoid problems with spanning tree blocking ports and causing a loss of connectivity within the VLAN. When a VLAN spans multiple switches, it is recommended that the VLAN remain within the same Spanning Tree Group
(have the same STG ID) across all the switches.
108 Chapter 5: Spanning Tree Group 42C4911, January 2007
Alteon OS Application Guide
If ports are tagged, all trunked ports can belong to multiple STGs.
A port that is not a member of any VLAN cannot be added to any STG. The port must be added to a VLAN, and that VLAN added to the desired STG.
Rules for VLAN Tagged ports
Tagged ports can belong to more than one STG, but untagged ports can belong to only one
STG.
When a tagged port belongs to more than one STG, the egress BPDUs are tagged to distinguish the BPDUs of one STG from those of another STG.
An untagged port cannot span multiple STGs.
Adding and removing ports from STGs
When you add a port to a VLAN that belongs to an STG, the port is also added to the STG.
However, if the port you are adding is an untagged port and is already a member of an
STG, that port will not be added to an additional STG because an untagged port cannot belong to more that one STG.
For example, assume that VLAN 1 belongs to STG 1. You add an untagged port, port 1, that does not belong to any STG to VLAN 1, and port 1 will become part of STG 1.
If you add untagged port 5 (which is a member to STG 2) to STG 1, the switch will prompt you to change the PVID from 2 to 1:
"Port 5 is an UNTAGGED port and its current PVID is 2.
Confirm changing PVID from 2 to 1 [y/n]:" y
When you remove a port from VLAN that belongs to an STG, that port will also be removed from the STG. However, if that port belongs to another VLAN in the same STG, the port remains in the STG.
As an example, assume that port 1 belongs to VLAN 1, and VLAN 1 belongs to STG 1.
When you remove port 1 from VLAN 1, port 1 is also removed from STG 1.
However, if port 1 belongs to both VLAN 1 and VLAN 2 and both VLANs belong to
STG 1, removing port 1 from VLAN 1 does not remove port 1 from STG 1 because
VLAN 2 is still a member of STG 1.
An STG cannot be deleted, only disabled. If you disable the STG while it still contains
VLAN members, Spanning Tree will be off on all ports belonging to that VLAN.
The relationship between port, trunk groups, VLANs, and Spanning Trees is shown in
42C4911, January 2007 Chapter 5: Spanning Tree Group 109
Alteon OS Application Guide
Multiple Spanning Trees
Each GbE Switch Module supports a maximum of 128 Spanning Tree Groups (STGs). Multiple STGs provide multiple data paths, which can be used for load-balancing and redundancy.
You enable load balancing between two GbE Switch Modules using multiple STGs by configuring each path with a different VLAN and then assigning each VLAN to a separate STG. Each
STG is independent. Each STG sends its own Bridge Protocol Data Units (BPDUs), and each
STG must be independently configured.
The STG, or bridge group, forms a loop-free topology that includes one or more virtual LANs
(VLANs). The switch supports 128 STGs running simultaneously. The default STG 1 may contain an unlimited number of VLANs. All other STGs 2-128 may contain only one VLAN each.
Default Spanning Tree configuration
In the default configuration, a single STG with the ID of 1 includes all non-management ports on the switch. It is called the default STG. Although ports can be added to or deleted from the default STG, the default STG (STG 1) itself cannot be deleted from the system.
All other STGs, except the default STG 1 and the management STG 127 and STG 128, are empty and VLANs must be added by the user. However, you cannot assign ports directly to an STG. Add ports to a VLAN and add the VLAN to the STG. The default configuration of management STG 127 contains VLAN 4094 and port EXT7. The default configuration of management STG 128 contains VLAN 4095 and internal management ports MGT1 and
MGT2.
Each STG is enabled by default, and assigned an ID number from 2 to 126. By default, the spanning tree on the management ports (MGT1, MGT2, and EXT7) is turned off in both STP/
PVST+ mode and in MSTP/RSTP mode.
110 Chapter 5: Spanning Tree Group 42C4911, January 2007
Alteon OS Application Guide
Why Do We Need Multiple Spanning Trees?
Figure 5-1 shows a simple example of why we need multiple Spanning Trees. Two VLANs,
VLAN 1 and VLAN 100 exist between application switch A and GbE Switch Module B. If you have a single Spanning Tree Group, the switches see an apparent loop, and one VLAN may become blocked, affecting connectivity, even though no actual loop exists.
If VLAN 1 and VLAN 100 belong to different Spanning Tree Groups, then the two instances of Spanning Tree separate the topology without forming a loop. Both VLANs can forward packets between the switches without losing connectivity.
BladeCenter
Figure 5-1 Using Multiple Instances of Spanning Tree Group
Switch-Centric Spanning Tree Group
, VLAN 2 is shared by application switch A and GbE Switch Module
B on ports 8 and 17 respectively. Application Switch A identifies VLAN 2 in Spanning Tree
Group 2 and GbE Switch Module B identifies VLAN 2 in Spanning Tree Group 1. Spanning
Tree Group is switch-centric—it is used to identify the VLANs participating in the Spanning
Tree Groups. The Spanning Tree Group ID is not transmitted in the BPDU. Each Spanning
Tree decision is based on the configuration of that switch.
42C4911, January 2007 Chapter 5: Spanning Tree Group 111
Alteon OS Application Guide
BladeCenter
Figure 5-2 Implementing Multiple Spanning Tree Groups
VLAN Participation in Spanning Tree Groups
The VLAN participation for each Spanning Tree Group in
is discussed in the following sections:
VLAN 1 Participation
If application switch A is the root bridge, then application switch A will transmit the
BPDU for VLAN 1 on ports 1 and 2. Application switch C receives the BPDU on its port 2 and application switch D receives the BPDU on its port 1. Application switch D will block port 8 or application switch C will block port 1 depending on the information provided in the BPDU.
VLAN 2 Participation
Application switch A, the root bridge generates another BPDU for Spanning Tree Group 2 and forwards it out from port 8. GbE Switch Module B receives this BPDU on its port 17.
Port 17 on GbE Switch Module B is on VLAN 2, Spanning Tree Group 2. Because switch
B has no additional ports participating in Spanning Tree Group 1, this BPDU is not forwarded to any additional ports and application switch A remains the designated root.
112 Chapter 5: Spanning Tree Group 42C4911, January 2007
Alteon OS Application Guide
VLAN 3 Participation
For VLAN 3 you can have GbE Switch Module B or application switch C to be the root bridge. If switch B is the root bridge for VLAN 3, Spanning Tree Group 2, then switch B transmits the BPDU out from port 18. Application switch C receives this BPDU on port 8 and is identified as participating in VLAN 3, Spanning Tree Group 2. Since application switch C has no additional ports participating in Spanning Tree Group 2, this BPDU is not forwarded to any additional ports and GbE Switch Module B remains the designated root.
Configuring Multiple Spanning Tree Groups
This configuration shows how to configure the three instances of Spanning Tree Groups on the switches A, B, C, and D illustrated in
.
By default Spanning Trees 2-126 are empty, and Spanning Tree Group 1 contains all configured VLANs until individual VLANs are explicitly assigned to other Spanning Tree Groups.
You can have only one VLAN per Spanning Tree Group except for Spanning Tree Group 1.
1.
Configure the following on application switch A:
Add port 8 to VLAN 2 and define Spanning Tree Group 2 for VLAN 2.
>> # /cfg/l2/vlan2
>> VLAN 2# add 8
>> VLAN 2# ../stg 2
>> Spanning Tree Group 2# add 2
(Select VLAN 2 menu)
(Add port 8)
(Select Spanning Tree Group 2)
(Add VLAN 2)
VLAN 2 is automatically removed from Spanning Tree Group 1.
2.
Configure the following on GbE Switch Module B:
Add port 17 to VLAN 2, port 18 to VLAN 3 and define Spanning Tree Group 2 for VLAN 3.
>> # /cfg/l2/vlan2
>> VLAN 2# add 17
>> VLAN 2# ../vlan3
>> VLAN 3# add 18
>> VLAN 3# ../stg 2
>> Spanning Tree Group 2# add 3
(Select VLAN 2 menu)
(Add port 17)
(Select VLAN 3 menu)
(Add port 18)
(Select Spanning Tree Group 2)
(Add VLAN 3)
VLAN 3 is removed from Spanning Tree Group 1 and, by default, VLAN 2 remains in
Spanning Tree Group 1.
42C4911, January 2007 Chapter 5: Spanning Tree Group 113
Alteon OS Application Guide
N OTE – Each instance of Spanning Tree Group is enabled by default.
3.
Configure the following on application switch C:
Add port 8 to VLAN 3 and define Spanning Tree Group 3 for VLAN 3.
>> # /cfg/l2/vlan3
>> VLAN 3# add 8
>> VLAN 3# ../stg 2
>> Spanning Tree Group 2# add 3
(Select VLAN 3 menu)
(Add port 8)
(Select Spanning Tree Group 2)
(Add VLAN 3)
VLAN 3 is automatically removed from Spanning Tree Group 1 and by default VLAN 2 remains in Spanning Tree Group 1.
N OTE – Application Switch D does not require any special configuration for multiple Spanning
Trees, because it is configured for the default Spanning Tree Group (STG 1) only.
114 Chapter 5: Spanning Tree Group 42C4911, January 2007
Alteon OS Application Guide
Port Fast Forwarding
Port Fast Forwarding permits a port that participates in Spanning Tree to bypass the Listening and Learning states and enter directly into the Forwarding state. While in the Forwarding state, the port listens to the BPDUs to learn if there is a loop and, if dictated by normal STG behavior
(following priorities, etc.), the port transitions into the Blocking state.
This feature permits the GbE Switch Module to interoperate well within Rapid Spanning Tree
(RSTP) networks.
Configuring Port Fast Forwarding
Use the following CLI commands to enable Port Fast Forwarding on an external port.
>> # /cfg/port ext1
>> Port EXT1# fastfwd ena
>> Port EXT1# apply
>> Port EXT1# save
(Select port EXT 1)
(Enable Port Fast Forwarding)
(Make your changes active)
(Save for restore after reboot)
42C4911, January 2007 Chapter 5: Spanning Tree Group 115
Alteon OS Application Guide
Fast Uplink Convergence
Fast Uplink Convergence enables the GbESM to quickly recover from the failure of the primary link or trunk group in a Layer 2 network using Spanning Tree Protocol. Normal recovery can take as long as 50 seconds, while the backup link transitions from Blocking to Listening to
Learning and then Forwarding states. With Fast Uplink Convergence enabled, the GbESM immediately places the secondary path into Forwarding state, and sends multicasts of addresses in the forwarding database (FDB) and ARP table over the secondary link so that upstream switches can learn the new path.
Configuration Guidelines
When you enable Fast Uplink Convergence, Alteon OS automatically makes the following configuration changes:
Sets the bridge priority to 65535 so that it does not become the root switch.
Increases the cost of all of the external ports by 3000, across all VLANs and Spanning
Tree Groups. This ensures that traffic never flows through the GbESM to get to another switch unless there is no other path.
These changes are reversed if the feature is disabled.
Configuring Fast Uplink Convergence
Use the following CLI commands to enable Fast Uplink Convergence on external ports.
>> # /cfg/l2/upfast ena
>> Layer 2# apply
>> Layer 2# save
(Enable Fast Uplink convergence)
(Make your changes active)
(Save for restore after reboot)
116 Chapter 5: Spanning Tree Group 42C4911, January 2007
C HAPTER 6
Rapid Spanning Tree Protocol/Multiple
Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree Protocol enhances the Spanning Tree Protocol to provide rapid convergence on Spanning Tree Group 1. IEEE 802.1s Multiple Spanning Tree Protocol extends the Rapid Spanning Tree Protocol, to provide both rapid convergence and load balancing in a VLAN environment.
The following topics are discussed in this chapter:
“Rapid Spanning Tree Protocol” on page 118
“Port State Changes” on page 118
“Port Type and Link Type” on page 119
“RSTP Configuration Guidelines” on page 119
“RSTP Configuration Example” on page 120
“Multiple Spanning Tree Protocol” on page 121
“Common Internal Spanning Tree” on page 121
“MSTP Configuration Guidelines” on page 122
“MSTP Configuration Example” on page 122
42C4911, January 2007 117
Alteon OS Application Guide
Rapid Spanning Tree Protocol
Rapid Spanning Tree Protocol (RSTP) provides rapid convergence of the spanning tree and provides for fast re-configuration critical for networks carrying delay-sensitive traffic such as voice and video. RSTP significantly reduces the time to reconfigure the active topology of the network when changes occur to the physical topology or its configuration parameters. RSTP reduces the bridged-LAN topology to a single Spanning Tree.
For more information about Spanning Tree Protocol, see
Chapter 5, “Spanning Tree Group.”
RSTP parameters are configured in Spanning Tree Group 1. STP Groups 2-128 do not apply to
RSTP, and must be cleared. There are new STP parameters to support RSTP, and some values to existing parameters are different.
RSTP is compatible with devices that run 802.1d Spanning Tree Protocol. If the switch detects
802.1d BPDUs, it responds with 802.1d-compatible data units. RSTP is not compatible with
Per VLAN Spanning Tree (PVST+) protocol.
Port State Changes
The port state controls the forwarding and learning processes of Spanning Tree. In RSTP, the port state has been consolidated to the following: discarding, learning, and forwarding.
compares the port states between 802.1d Spanning Tree and 802.1w Rapid Spanning Trees.
Table 3 RSTP vs. STP Port states
Operational status
Enabled
Enabled
Enabled
Enabled
Disabled
STP Port State
Blocking
Listening
Learning
Forwarding
Disabled
RSTP Port State
Discarding
Discarding
Learning
Forwarding
Discarding
118 Chapter 6: Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol 42C4911, January 2007
Alteon OS Application Guide
Port Type and Link Type
Spanning Tree configuration includes the following parameters to support
RSTP and MSTP: edge port and link type. Although these parameters are configured for
Spanning Tree Groups 1-128 (/cfg/l2/stg x/port x), they only take effect when
RSTP/MSTP is turned on.
Edge Port
A port that does not connect to a bridge is called an edge port. Edge ports generally connect to a server, therefore, ports INT1-INT14 should have edge enabled. Edge ports can start forwarding as soon as the link is up.
Edge ports do not take part in Spanning Tree, and should not receive BPDUs. If a port with edge enabled does receive a BPDU, it begins STP processing only if it is connected to a spanning tree bridge. If it is connected to a host, the edge port ignores BPDUs.
Link Type
The link type determines how the port behaves in regard to Rapid Spanning Tree. The link type corresponds to the duplex mode of the port. A full-duplex link is point-to-point (p2p), while a half-duplex link should be configured as shared. If you select auto as the link type, the port dynamically configures the link type.
RSTP Configuration Guidelines
This section provides important information about configuring Rapid Spanning Tree Groups:
When RSTP is turned on, STP parameters apply only to STP Group 1.
When RSTP is turned on, STG 2-126 are turned off.
42C4911, January 2007 Chapter 6: Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol 119
Alteon OS Application Guide
RSTP Configuration Example
This section provides steps to configure Rapid Spanning Tree on the GbE Switch Module, using the Command-Line Interface (CLI).
Configure Rapid Spanning Tree
1.
Configure port and VLAN membership on the switch.
2.
Disable and clear STP groups 2 through 126.
>> /cfg/l2/stg 2
>> Spanning Tree Group 2# clear
>> Spanning Tree Group 2# off
(Select Spanning Tree Group 2)
(Clear STP Group 2 parameters)
(Turn off STP Group 2)
3.
Set the Spanning Tree mode to Rapid Spanning Tree.
>> /cfg/l2/mrst
>> Multiple Spanning Tree# mode rstp
>> Multiple Spanning Tree# on
(Select Multiple Spanning Tree menu)
(Set mode to Rapid Spanning Tree)
(Turn Rapid Spanning Tree on)
4.
Configure STP Group 1 parameters.
>> /cfg/l2/stg 1
>> Spanning Tree Group 1# add 2
>> Spanning Tree Group 1# apply
(Select Spanning Tree Protocol menu)
(Add VLAN 2 STP Group 1)
(Apply the configurations)
120 Chapter 6: Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol 42C4911, January 2007
42C4911, January 2007
Alteon OS Application Guide
Multiple Spanning Tree Protocol
IEEE 802.1s Multiple Spanning Tree extends the IEEE 802.1w Rapid Spanning Tree Protocol through multiple Spanning Tree Groups. MSTP maintains up to 32 spanning-tree instances, that correspond to STP Groups 1-32.
For more information about Spanning Tree Protocol, see
Chapter 5, “Spanning Tree Group.”
In Multiple Spanning Tree Protocol (MSTP), several VLANs can be mapped to each Spanning-Tree instance. Each Spanning-Tree instance is independent of other instances. MSTP allows frames assigned to different VLANs to follow separate paths, each path based on an independent Spanning-Tree instance. This approach provides multiple forwarding paths for data traffic, enabling load-balancing, and reducing the number of Spanning-Tree instances required to support a large number of VLANs.
By default, the spanning tree on the management ports is turned off in both STP/PVST+ mode and in MSTP/RSTP mode.
MSTP Region
A group of interconnected bridges that share the same attributes is called an MST region. Each bridge within the region must share the following attributes:
Alphanumeric name
Revision number
VLAN-to STG mapping scheme
MSTP provides rapid re-configuration, scalability and control due to the support of regions, and multiple Spanning-Tree instances support within each region.
Common Internal Spanning Tree
The Common Internal Spanning Tree (CIST) provides a common form of Spanning Tree Protocol, with one Spanning-Tree instance that can be used throughout the MSTP region. CIST allows the switch to interoperate with legacy equipment, including devices that run IEEE
802.1d (STP).
CIST allows the MSTP region to act as a virtual bridge to other bridges outside of the region, and provides a single Spanning-Tree instance to interact with them.
CIST port configuration includes Hello time, Edge port enable/disable, and Link Type. These parameters do not affect Spanning Tree Groups 1-128. They apply only when the CIST is used.
Chapter 6: Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol 121
Alteon OS Application Guide
MSTP Configuration Guidelines
This section provides important information about configuring Multiple Spanning Tree
Groups:
When you enable MSTP, you must configure the Region Name, and a default version number of 1 is configured automatically.
Each bridge in the region must have the same name, version number, and VLAN mapping.
MSTP Configuration Example
This section provides steps to configure Multiple Spanning Tree Protocol on the GbE Switch
Module, using the Command-Line Interface (CLI).
Configure Multiple Spanning Tree Protocol
1.
Configure port and VLAN membership on the switch.
2.
Set the mode to Multiple Spanning Tree, and configure MSTP region parameters.
>> /cfg/l2/mrst
>> Multiple Spanning Tree# mode mstp
>> Multiple Spanning Tree# on
>> Multiple Spanning Tree# name xxxxxx
(Select Multiple Spanning Tree menu)
(Set mode to Multiple Spanning Trees)
(Turn Multiple Spanning Trees on)
(Define the Region name)
3.
Assign VLANs to Spanning Tree Groups.
>> /cfg/l2/stg 2
>> Spanning Tree Group 2# add 2
(Select Spanning Tree Group 2)
(Add VLAN 2)
122 Chapter 6: Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol 42C4911, January 2007
C HAPTER 7
Quality of Service
Quality of Service features allow you to allocate network resources to mission-critical applications at the expense of applications that are less sensitive to such factors as time delays or network congestion. You can configure your network to prioritize specific types of traffic, ensuring that each type receives the appropriate Quality of Service (QoS) level.
The following topics are discussed in this section:
“Using ACL Filters” on page 126
“Using DSCP Values to Provide QoS” on page 134
“Using 802.1p Priorities to Provide QoS” on page 139
“Queuing and Scheduling” on page 140
42C4911, January 2007 123
Alteon OS Application Guide
Overview
QoS helps you allocate guaranteed bandwidth to the critical applications, and limit bandwidth for less critical applications. Applications such as video and voice must have a certain amount of bandwidth to work correctly; using QoS, you can provide that bandwidth when necessary.
Also, you can put a high priority on applications that are sensitive to timing out or cannot tolerate delay by assigning that traffic to a high-priority queue.
By assigning QoS levels to traffic flows on your network, you can ensure that network resources are allocated where they are needed most. QoS features allow you to prioritize network traffic, thereby providing better service for selected applications.
Figure 7-1 shows the basic QoS model used by the GbESM.
Ingress Ports Classify
Packets
Meter
Traffic
Perform
Actions
ACL
Filter
ACL
Meter
Drop/Pass/
Re-Mark
Queue and
Schedule
COS
Queue
Egress
Figure 7-1 QoS Model
The GbESM uses the Differentiated Services (DiffServ) architecture to provide QoS functions.
DiffServ is described in IETF RFCs 2474 and 2475.
With DiffServ, you can establish policies to direct traffic. A policy is a traffic-controlling mechanism that monitors the characteristics of the traffic, (for example, its source, destination, and protocol) and performs a controlling action on the traffic when certain characteristics are matched.
The GbESM can classify traffic by reading the DiffServ Code Point (DSCP) or IEEE 802.1p priority value, or by using filters to match specific criteria. When network traffic attributes match those specified in a traffic pattern, the policy instructs the GbESM to perform specified actions on each packet that passes through it. The packets are assigned to different Class of
Service (COS) queues and scheduled for transmission.
124 Chapter 7: Quality of Service 42C4911, January 2007
Alteon OS Application Guide
The basic GbESM QoS model works as follows:
Classify traffic:
Read DSCP
Read 802.1p Priority
Match ACL filter parameters
Meter traffic:
Define bandwidth and burst parameters
Select actions to perform on in-profile and out-of-profile traffic
Perform actions:
Drop packets
Pass packets
Mark DSCP or 802.1p Priority
Set COS queue (with or without re-marking)
Queue and schedule traffic:
Place packets in one of two COS queues
Schedule transmission based on the COS queue weight
42C4911, January 2007 Chapter 7: Quality of Service 125
Alteon OS Application Guide
Using ACL Filters
Access Control Lists are filters that allow you to classify and segment traffic, so you can provide different levels of service to different traffic types. Each filter defines the conditions that must match for inclusion in the filter, and also the actions that are performed when a match is made.
Summary of packet classifiers
The GbESM allows you to classify packets based on various parameters, such as:
Ethernet
S ource MAC address
D estination MAC address
IPv4
VLAN number/mask
Ethernet type
Ethernet Priority, which is the IEEE 802.1p Priority
S ource IP address/mask
D estination address/mask
Type of Service value
IP protocol number protocol number or name as shown in
:.
Table 7-1 Well-Known Protocol Types
Number Protocol Name
1
2
6
17
89
112 icmp igmp tcp udp ospf vrrp
TCP/UDP
TCP/UDP application source port as shown in
TCP/UDP application destination port as shown in Table 7-2 on page 127
TCP/UDP flag value as shown in Table 7-3 on page 127
126 Chapter 7: Quality of Service 42C4911, January 2007
Alteon OS Application Guide
Table 7-2 Well-Known Application Ports
Number TCP/UDP
Application
20
21
22
23
25
37
42
43
53
69
70 ftp-data ftp ssh telnet smtp time name whois domain tftp gopher
Number TCP/UDP
Application
79
80
109
110
111
119
123
143
144
161
162 finger http pop2 pop3 sunrpc nntp ntp imap news snmp snmptrap
Table 7-3 Well-Known TCP flag values
Flag
URG
ACK
PSH
RST
SYN
FIN
Value
0x0020
0x0010
0x0008
0x0004
0x0002
0x0001
Packet Format
Ethernet format (eth2, SNAP, LLC)
Ethernet tagging format
IP format (IPv4, IPv6)
Egress port packets
Number
179
194
220
389
443
520
554
1645, 1812
1813
1985
TCP/UDP
Application bgp irc imap3 ldap https rip rtsp
Radius
Radius Accounting hsrp
42C4911, January 2007 Chapter 7: Quality of Service 127
Alteon OS Application Guide
Summary of ACL Actions
Actions determine how the traffic is treated. The GbESM QoS actions include the following:
Pass or Drop
Re-mark a new DiffServ Code Point (DSCP)
Re-mark the 802.1p field
Set the COS queue
Understanding ACL Precedence
Each ACL has a unique precedence level, based on its number. When an incoming packet matches the highest precedence ACL, the ACL’s configured action takes place. The other assigned ACLs also are considered, in order of precedence.
ACLs are divided into seven major Precedence Groups, as shown in Table 7-4 .
Table 7-4 ACL Precedence Groups
Precedence Group
Precedence Group 1
Precedence Group 2
Precedence Group 3
ACLs
ACL 1 - ACL 128
ACL 129 - ACL 256
ACL 257 - ACL 384
Precedence Level
Low
High
N OTE – Precedence Groups are not related to ACL Groups.
Each Precedence Group has its own precedence level, such that Precedence Group 2 has a higher precedence level than Precedence Group 1. Within each Precedence Group, the lowestnumbered ACL has the lowest precedence level, and the highest-numbered ACL has the highest precedence level. However, the other ACLs within the Precedence Group have an unspecified precedence level, as follows:
ACL 1 = lowest precedence level within Precedence Group 1
ACL 2 = unspecified precedence level within Precedence Group 1
ACL 3 = unspecified precedence level within Precedence Group 1
...
ACL 126 = unspecified precedence level within Precedence Group 1
ACL 127 = unspecified precedence level within Precedence Group 1
ACL 128 = highest precedence level within Precedence Group 1
128 Chapter 7: Quality of Service 42C4911, January 2007
Alteon OS Application Guide
Using ACL Groups
Access Control Lists (ACLs) allow you to classify packets according to a particular content in the packet header, such as the source address, destination address, source port number, destination port number, and others. Packet classifiers identify flows for more processing.
You can define a traffic profile by compiling a number of ACLs into an ACL Group, and assigning the ACL Group to a port.
ACL Groups are assigned and enabled on a per-port basis. Each ACL can be used by itself or in combination with other ACLs or ACL Groups on a given switch port.
ACLs can be grouped in the following manner:
Access Control Lists
Access Control Lists (ACLs) allow you to classify packets according to a particular content in the packet header, such as the source address, destination address, source port number, destination port number, and others. Packet classifiers identify flows for more processing.
The GbESM supports up to 384 ACLs. Each ACL defines one filter rule. Each filter rule is a collection of matching criteria, and can include an action (permit or deny the packet).
For example:
ACL 1:
VLAN = 1
SIP = 10.10.10.1 (255.255.255.0)
Action = permit
42C4911, January 2007 Chapter 7: Quality of Service 129
Alteon OS Application Guide
Access Control Groups
An Access Control Group (ACL Group) is a collection of ACLs. For example:
ACL Group 1
ACL 1:
VLAN = 1
SIP = 10.10.10.1 (255.255.255.0)
Action = permit
ACL 2:
VLAN = 2
SIP = 10.10.10.2 (255.255.255.0)
Action = deny
ACL 3:
Priority = 7
DIP = 10.10.10.3 (255.255.255.0)
Action = permit
In the example above, each ACL defines a filter rule. ACL 3 has a higher precedence than
ACL 1, based on its number.
Use ACL Groups to create a traffic profile by gathering ACLs into an ACL Group, and assigning the ACL Group to a port. The GbESM supports up to 384 ACL Groups.
ACL Metering and Re-marking
You can define a profile for the aggregate traffic flowing through the GbESM ports, by configuring a QoS meter (if desired), and assigning ACL Groups to ports. When you add ACL
Groups to a port, make sure they are ordered correctly in terms of precedence.
For example, consider two ACL Groups, ACL Group 1 and ACL Group 2. Each contains three levels of precedence. If you add ACL Group 1 to a port, then add ACL Group 2 to the port, the port’s ACL filters contain a total of six precedence levels. ACL Group 1 has precedence over
ACL Group 2.
Each port supports up to seven precedence levels.
Actions taken by an ACL are called In-Profile actions. You can configure additional In-Profile and Out-of-Profile actions on a port. Data traffic can be metered, and re-marked to ensure that the traffic flow provides certain levels of service in terms of bandwidth for different types of network traffic.
130 Chapter 7: Quality of Service 42C4911, January 2007
Alteon OS Application Guide
Metering
QoS metering provides different levels of service to data streams through user-configurable parameters. A meter is used to measure the traffic stream against a traffic profile, which you create. Thus, creating meters yields In-Profile and Out-of-Profile traffic for each ACL, as follows:
In-Profile–If there is no meter configured or if the packet conforms to the meter, the packet is classified as In-Profile.
Out-of-Profile–If a meter is configured and the packet does not conform to the meter
(exceeds the committed rate or maximum burst rate of the meter), the packet is classified as Out-of-Profile.
Using meters, you set a Committed Rate in Kb/s (1000 bits per second in each Kb/s). All traffic within this Committed Rate is In-Profile. Additionally, you set a Maximum Burst Size that specifies an allowed data burst larger than the Committed Rate for a brief period. These parameters define the In-Profile traffic.
Meters keep the sorted packets within certain parameters. You can configure a meter on an
ACL, and perform actions on metered traffic, such as packet re-marking.
Re-Marking
Re-marking allows for the treatment of packets to be reset based on new network specifications or desired levels of service. You can configure the ACL to re-mark a packet as follows:
Change the DSCP value of a packet, used to specify the service level traffic should receive.
Change the 802.1p priority of a packet.
Viewing ACL Statistics
ACL statistics display how many packets hit (matched) each ACL. Use ACL statistics to check filter performance, and debug the ACL filters.
You must enable statistics (cfg/acl/acl x/stats ena) for each ACL that you want to monitor.
42C4911, January 2007 Chapter 7: Quality of Service 131
Alteon OS Application Guide
ACL Configuration Examples
Example 1
Use this configuration to block traffic to a specific host. All traffic that ingresses on port EXT1 is denied if it is destined for the host at IP address 100.10.1.1
1.
Configure an Access Control List.
>> Main# cfg/acl/acl 1
>> ACL 1# ipv4/dip 100.10.1.1
(Define ACL 1)
Enter destination IP address mask (default 255.255.255.255):
>> Filtering IPv4# ..
>> ACL 1# action deny
2.
Add ACL 1 to port EXT1.
>> Main# cfg/port ext1/aclqos
>> Port EXT1 ACL# /add acl 1
3.
Apply and save the configuration.
>> Port EXT1 ACL# apply
>> Port EXT1 ACL# save
(Select port EXT 1 to assign ACLs)
(Assign ACL 1 to the port)
Example 2
Use this configuration to block traffic from a network destined for a specific host address. All traffic that ingresses in port EXT2 with source IP from the class 100.10.1.0/24 and destination
IP 200.20.2.2 is denied.
1.
Configure an Access Control List.
>> Main# cfg/acl/acl 2 (Define ACL 2)
>> ACL 2# ipv4/sip 100.10.1.0 255.255.255.0
>> Filtering IPv4# ipv4/dip 200.20.2.2 255.255.255.255
>> Filtering IPv4# ..
>> ACL 2# action deny
2.
Add ACL 2 to port EXT2.
>> Main# cfg/port ext2/aclqos
>> Port EXT2 ACL# /add acl 2
(Select port EXT2 to assign ACLs)
(Assign ACL 2 to the port)
132 Chapter 7: Quality of Service 42C4911, January 2007
Alteon OS Application Guide
3.
Apply and save the configuration.
>> Port EXT2 ACL# apply
>> Port EXT2 ACL# save
Example 3
Use this configuration to block traffic from a network that is destined for a specific egress port.
All traffic that ingresses port EXT1 from the network 100.10.1.0/24 and is destined for port
INT1 is denied.
1.
Configure an Access Control List.
>> Main# cfg/acl/acl 3 (Define ACL 3)
>> ACL 3# ipv4/sip 100.10.1.0 255.255.255.0
>> Filtering IPv4# ..
>> ACL 3# egrport int1
>> ACL 3# ..
>> ACL 3# action deny
2.
Add ACL 3 to port EXT1.
>> Main# cfg/port ext1/aclqos
>> Port EXT1 ACL# /add acl 3
3.
Apply and save the configuration.
>> Port EXT2 ACL# apply
>> Port EXT2 ACL# save
(Select port EXT1 to assign ACLs)
(Assign ACL 3 to the port)
42C4911, January 2007 Chapter 7: Quality of Service 133
Alteon OS Application Guide
Using DSCP Values to Provide QoS
The six most significant bits in the TOS byte of the IP header are defined as DiffServ Code
Points (DSCP). Packets are marked with a certain value depending on the type of treatment the packet must receive in the network device. DSCP is a measure of the Quality of Service (QoS) level of the packet.
Differentiated Services Concepts
To differentiate between traffic flows, packets can be classified by their DSCP value. The Differentiated Services (DS) field in the IP header is an octet, and the first six bits, called the DS
Code Point (DSCP), can provide QoS functions. Each packet carries its own QoS state in the
DSCP. There are 64 possible DSCP values (0-63).
Version
Length
ToS Length ID Offset TTL Proto FCS SIP DIP Data
Differentiated Services Code Point (DSCP) unused
7 6 5 4 3 2 1 0
Figure 7-2 Layer 3 IPv4 packet
The GbESM can perform the following actions to the DSCP:
Read the DSCP value of ingress packets
Re-mark the DSCP value to a new value
Map the DSCP value to an 802.1p priority
Once the DSCP value is marked, the GbESM can use it to direct traffic prioritization.
Per Hop Behavior
The DSCP value determines the Per Hop Behavior (PHB) of each packet. The PHB is the forwarding treatment given to packets at each hop. QoS policies are built by applying a set of rules to packets, based on the DSCP value, as they hop through the network.
134 Chapter 7: Quality of Service 42C4911, January 2007
Alteon OS Application Guide
The GbESM default settings are based on the following standard PHBs, as defined in the IEEE standards:
Expedited Forwarding (EF)—This PHB has the highest egress priority and lowest drop precedence level. EF traffic is forwarded ahead of all other traffic. EF PHB is described in
RFC 2598.
Assured Forwarding (AF)—This PHB contains four service levels, each with a different drop precedence, as shown below. Routers use drop precedence to determine which packets to discard last when the network becomes congested. AF PHB is described in
RFC 2597.
Class 1 Class 2 Class 3 Class 4 Drop
Precedence
Low
Medium
High
AF11 (DSCP 10) AF21 (DSCP 18) AF31 (DSCP 26) AF41 (DSCP 34)
AF12 (DSCP 12) AF22 (DSCP 20) AF32 (DSCP 28) AF42 (DSCP 36)
AF13 (DSCP 14) AF23 (DSCP 22) AF33 (DSCP 30) AF43 (DSCP 38)
Class Selector (CS)—This PHB has eight priority classes, with CS7 representing the highest priority, and CS0 representing the lowest priority, as shown below. CS PHB is described in RFC 2474.
Priority
Highest
Lowest
Class Selector
CS7
CS6
CS5
CS4
CS3
CS2
CS1
CS0
DSCP
56
48
40
32
24
16
8
0
42C4911, January 2007 Chapter 7: Quality of Service 135
Alteon OS Application Guide
QoS Levels
Table 7-5 shows the default service levels provided by the GbESM, listed from highest to
lowest importance:
Table 7-5 Default QoS Service Levels
Service Level
Critical
Network Control
Premium
Platinum
Gold
Silver
Bronze
Standard
Default PHB
CS7
CS6
EF, CS5
AF41, AF42, AF43, CS4
AF31, AF32, AF33, CS3
AF21, AF22, AF23, CS2
AF11, AF12, AF13, CS1
DF, CS0
802.1p Priority
7
4
3
6
5
2
1
0
136 Chapter 7: Quality of Service 42C4911, January 2007
Alteon OS Application Guide
DSCP Re-marking and Mapping
The GbESM can re-mark the DSCP value of ingress packets to a new value, and set the
802.1p priority value, based on the DSCP value. You can view the default settings by using the cfg/qos/dscp/cur command, as shown below.
>> DSCP Remark# cur
Current DSCP Remarking Configuration: OFF
DSCP New DSCP New 802.1p Prio
-------- -------- ---------------
0 0 0
1 1 0
...
51 51 0
52 52 0
53 53 0
54 54 0
55 55 0
56 56 7
57 57 0
58 58 0
59 59 0
60 60 0
61 61 0
62 62 0
63 63 0
Use the cfg/qos/dscp/on command to turn on DSCP re-marking globally. Then you must enable DSCP re-marking (cfg/port x/dscpmrk/ena) on any port that you wish to perform this function.
N OTE – If an ACL meter is configured for DSCP re-marking, the meter function takes precedence over QoS re-marking.
42C4911, January 2007 Chapter 7: Quality of Service 137
Alteon OS Application Guide
DSCP Re-marking Configuration Example
1.
Turn DSCP re-marking on globally, and define the DSCP-DSCP-802.1p mapping. You can use the default mapping, as shown in the cfg/qos/dscp/cur command output.
>> Main# cfg/qos/dscp/on
>> DSCP Remark# dscp 8
Current DSCP remark (for DSCP 8): 8
(Turn on DSCP re-marking)
(Define DSCP re-marking)
Enter new DSCP remark (for DSCP 8) [0-63]: 10
>> DSCP Remark# prio (Define DSCP-to-802.1p mapping)
Enter DSCP [0-63]: 10
Current prio (for DSCP 10): 1
Enter new prio (for DSCP 10) [0-7]: 2
>> DSCP Remark# apply
2.
Enable DSCP re-marking on a port.
>> Main# cfg/port EXT1
>> Port EXT1# dscpmrk ena
Current DSCP remarking: disabled
New DSCP remarking: enabled
>> Port EXT1# apply
(Select port)
(Enable DSCP re-marking)
138 Chapter 7: Quality of Service 42C4911, January 2007
Alteon OS Application Guide
Using 802.1p Priorities to Provide QoS
Alteon OS provides Quality of Service functions based on the priority bits in a packet’s VLAN header. (The priority bits are defined by the 802.1p standard within the IEEE 802.1q VLAN header.) The 802.1p bits, if present in the packet, specify the priority that should be given to packets during forwarding. Packets with a numerically higher (non-zero) priority are given forwarding preference over packets with lower priority bit value.
The IEEE 802.1p standard uses eight levels of priority (0-7). Priority 7 is assigned to highest priority network traffic, such as OSPF or RIP routing table updates, priorities 5-6 are assigned to delay-sensitive applications such as voice and video, and lower priorities are assigned to standard applications. A value of 0 (zero) indicates a “best effort” traffic prioritization, and this is the default when traffic priority has not been configured on your network. The GbESM can filter packets based on the 802.1p values, and it can assign or overwrite the 802.1p value in the packet.
Preamble SFD DMAC SMAC Tag E Type Data FCS
Priority VLAN Identifier (VID)
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Figure 7-3 Layer 2 802.1q/802.1p VLAN tagged packet
Ingress packets receive a priority value, as follows:
Tagged packets—GbESM reads the 802.1p priority in the VLAN tag.
Untagged packets—GbESM tags the packet and assigns an 802.1p priority, based on the port’s default priority (/cfg/port x/8021ppri).
Egress packets are placed in a COS queue based on the priority value, and scheduled for transmission based on the scheduling weight of the COS queue.
42C4911, January 2007 Chapter 7: Quality of Service 139
Alteon OS Application Guide
802.1p Configuration Example
1.
Configure a port’s default 802.1p priority.
>> Main# cfg/port EXT1
>> Port EXT1# 8021ppri
Current 802.1p priority: 0
Enter new 802.1p priority [0-7]: 1
>> Port EXT1# ena
>> Port EXT1# apply
(Select port)
(Set port’s default 802.1p priority)
2.
Map the 802.1p priority value to a COS queue and set the COS queue scheduling weight.
>> Main# cfg/qos/8021p
>> 802.1p# priq
Enter priority [0-7]: 1
(Select 802.1p menu)
(Set COS queue assignments)
Current COS queue (for priority 1): 0
Enter new COS queue (for priority 1) [0-1]: 1
>> 802.1p# qweight (Set COS queue weights)
Enter COS queue [0-1]: 1
Current weight (for COS queue 1): 3
Enter new weight (for COS queue 1) [0-15]: 10
>> 802.1p# apply
Queuing and Scheduling
The GbESM has eight output Class of Service (COS) queues per port, into which each packet is placed. Each packet’s 802.1p priority determines its COS queue, except when an ACL action sets the COS queue of the packet.
Each COS queue uses Weighted Round Robin (WRR) scheduling, with user configurable weight from 1 to 15. The weight of 0 (zero) indicates strict priority, which might starve the low priority queues.
You can configure the following attributes for COS queues:
Map 802.1p priority value to a COS queue
Define the scheduling weight of each COS queue
Use the 802.1p menu (/cfg/qos/8021p) to configure COS queues.
140 Chapter 7: Quality of Service 42C4911, January 2007
Part 2: IP Routing
This section discusses Layer 3 switching functions. In addition to switching traffic at near line rates, the application switch can perform multi-protocol routing. This section discusses basic routing and advanced routing protocols:
Basic Routing
Routing Information Protocol (RIP)
Internet Group Management Protocol (IGMP)
Border Gateway Protocol (BGP)
Open Shortest Path First (OSPF)
42C4911, January 2007
Alteon OS Application Guide
142 42C4911, January 2007
C HAPTER 8
Basic IP Routing
This chapter provides configuration background and examples for using the GbE Switch Module to perform IP routing functions. The following topics are addressed in this chapter:
“IP Routing Benefits” on page 144
“Routing Between IP Subnets” on page 145
“Example of Subnet Routing” on page 148
“Dynamic Host Configuration Protocol” on page 152
42C4911, January 2007 143
Alteon OS Application Guide
IP Routing Benefits
The GbE Switch Module uses a combination of configurable IP switch interfaces and IP routing options. The switch IP routing capabilities provide the following benefits:
Connects the server IP subnets to the rest of the backbone network.
Provides another means to invisibly introduce Jumbo frame technology into the serverswitched network by automatically fragmenting UDP Jumbo frames when routing to non-
Jumbo frame VLANs or subnets.
Provides the ability to route IP traffic between multiple Virtual Local Area Networks
(VLANs) configured on the switch.
144 Chapter 8: Basic IP Routing 42C4911, January 2007
Alteon OS Application Guide
Routing Between IP Subnets
The physical layout of most corporate networks has evolved over time. Classic hub/router topologies have given way to faster switched topologies, particularly now that switches are increasingly intelligent. GbE Switch Modules are intelligent and fast enough to perform routing functions on a par with wire speed Layer 2 switching.
The combination of faster routing and switching in a single device provides another service— it allows you to build versatile topologies that account for legacy configurations.
For example, consider the following topology migration:
GbE
Switch
Module
BladeCenter
Figure 8-1 The Router Legacy Network
In this example, a corporate campus has migrated from a router-centric topology to a faster, more powerful, switch-based topology. As is often the case, the legacy of network growth and redesign has left the system with a mix of illogically distributed subnets.
This is a situation that switching alone cannot cure. Instead, the router is flooded with crosssubnet communication. This compromises efficiency in two ways:
42C4911, January 2007 Chapter 8: Basic IP Routing 145
Alteon OS Application Guide
Routers can be slower than switches. The cross-subnet side trip from the switch to the router and back again adds two hops for the data, slowing throughput considerably.
Traffic to the router increases, increasing congestion.
Even if every end-station could be moved to better logical subnets (a daunting task), competition for access to common server pools on different subnets still burdens the routers.
This problem is solved by using GbE Switch Modules with built-in IP routing capabilities.
Cross-subnet LAN traffic can now be routed within the switches with wire speed Layer 2 switching performance. This not only eases the load on the router but saves the network administrators from reconfiguring each and every end-station with new IP addresses.
Take a closer look at the BladeCenter’s GbE Switch Module in the following configuration example:
10 Gbps
10 Gbps
GbESM
Server Subnet:
Figure 8-2 Switch-Based Routing Topology
The GbE Switch Module connects the Gigabit Ethernet and Fast Ethernet trunks from various switched subnets throughout one building. Common servers are placed on another subnet attached to the switch. A primary and backup router are attached to the switch on yet another subnet.
146 Chapter 8: Basic IP Routing 42C4911, January 2007
Alteon OS Application Guide
Without Layer 3 IP routing on the switch, cross-subnet communication is relayed to the default gateway (in this case, the router) for the next level of routing intelligence. The router fills in the necessary address information and sends the data back to the switch, which then relays the packet to the proper destination subnet using Layer 2 switching.
With Layer 3 IP routing in place on the GbE Switch Module, routing between different IP subnets can be accomplished entirely within the switch. This leaves the routers free to handle inbound and outbound traffic for this group of subnets.
To make implementation even easier, UDP Jumbo frame traffic is automatically fragmented to regular Ethernet frame sizes when routing to non-Jumbo frame VLANS or subnets. This automatic frame conversion allows servers to communicate using Jumbo frames, all transparently to the user.
42C4911, January 2007 Chapter 8: Basic IP Routing 147
Alteon OS Application Guide
Example of Subnet Routing
Prior to configuring, you must be connected to the switch Command Line Interface (CLI) as the administrator.
N OTE – For details about accessing and using any of the menu commands described in this example, see the Alteon OS Command Reference.
1.
Assign an IP address (or document the existing one) for each router and client workstation.
In the example topology in Figure 8-2 on page 146
, the following IP addresses are used:
Table 8-1 Subnet Routing Example: IP Address Assignments
3
4
Subnet
1
2
Devices IP Addresses
Primary and Secondary Default Routers 205.21.17.1 and 205.21.17.2
First Floor Client Workstations 100.20.10.2-254
Second Floor Client Workstations
Common Servers
131.15.15.2-254
206.30.15.2-254
2.
Assign an IP interface for each subnet attached to the switch.
Since there are four IP subnets connected to the switch, four IP interfaces are needed:
Table 8-2 Subnet Routing Example: IP Interface Assignments
Interface
IF 1
IF 2
IF 3
IF 4
Devices IP Interface Address
Primary and Secondary Default Routers 205.21.17.3
First Floor Client Workstations
Second Floor Client Workstations
Common Servers
100.20.10.1
131.15.15.1
206.30.15.1
148 Chapter 8: Basic IP Routing 42C4911, January 2007
Alteon OS Application Guide
IP interfaces are configured using the following commands at the CLI:
>> # /cfg/l3/if 1
>> IP Interface 1# addr 205.21.17.3
>> IP Interface 1# ena
>> IP Interface 1# ../if 2
>> IP Interface 2# addr 100.20.10.1
>> IP Interface 2# ena
>> IP Interface 2# ../if 3
>> IP Interface 3# addr 131.15.15.1
>> IP Interface 3# ena
>> IP Interface 3# ../if 4
>> IP Interface 4# addr 206.30.15.1
>> IP Interface 4# ena
(Select IP interface 1)
(Assign IP address for the interface)
(Enable IP interface 1)
(Select IP interface 2)
(Assign IP address for the interface)
(Enable IP interface 2)
(Select IP interface 3)
(Assign IP address for the interface)
(Enable IP interface 3)
(Select IP interface 4)
(Assign IP address for the interface)
(Enable IP interface 5)
3.
Set each server and workstation’s default gateway to the appropriate switch IP interface
(the one in the same subnet as the server or workstation).
4.
Configure the default gateways to the routers’ addresses.
Configuring the default gateways allows the switch to send outbound traffic to the routers:
>> IP Interface 5# ../gw 1
>> Default gateway 1# addr 205.21.17.1
>> Default gateway 1# ena
>> Default gateway 1# ../gw 2
>> Default gateway 2# addr 205.21.17.2
>> Default gateway 2# ena
(Select primary default gateway)
(Assign IP address for primary router)
(Enable primary default gateway)
(Select secondary default gateway)
(Assign address for secondary router)
(Enable secondary default gateway)
5.
Apply and verify the configuration.
>> Default gateway 2# # apply
>> Default gateway 2# /cfg/l3/cur
(Make your changes active)
(View current IP settings)
Examine the resulting information. If any settings are incorrect, make the appropriate changes.
6.
Save your new configuration changes.
>> IP# save (Save for restore after reboot)
42C4911, January 2007 Chapter 8: Basic IP Routing 149
Alteon OS Application Guide
Using VLANs to Segregate Broadcast Domains
In the previous example, devices that share a common IP network are all in the same broadcast domain. If you want to limit the broadcasts on your network, you could use VLANs to create distinct broadcast domains. For example, as shown in the following procedure, you could create one VLAN for the client trunks, one for the routers, and one for the servers.
In this example, you are adding to the previous configuration.
1.
Determine which switch ports and IP interfaces belong to which VLANs.
The following table adds port and VLAN information:
Table 8-3 Subnet Routing Example: Optional VLAN Ports
VLAN Devices
1 First Floor Client Workstations
Second Floor Client Workstations
2
3
Primary Default Router
Secondary Default Router
Common Servers 1
Common Servers 2
IP Interface Switch Port VLAN #
2
3
EXT1
EXT2
1
1
4
4
1
1
EXT3
EXT4
INT5
INT6
3
3
2
2
2.
Add the switch ports to their respective VLANs.
The VLANs shown in
are configured as follows:
>> # /cfg/l2/vlan 1
>> VLAN 1# add port EXT1
>> VLAN 1# add port EXT2
>> VLAN 1# ena
>> VLAN 1# ../VLAN 2
>> VLAN 2# add port EXT3
>> VLAN 2# add port EXT4
>> VLAN 2# ena
>> VLAN 2# ../VLAN 3
>> VLAN 3# add port INT5
>> VLAN 3# add port INT6
>> VLAN 3# ena
(Select VLAN 1)
(Add port for 1st floor to VLAN 1)
(Add port for 2nd floor to VLAN 1)
(Enable VLAN 1)
(Select VLAN 2)
(Add port for default router 1)
(Add port for default router 2)
(Enable VLAN 2)
(Add port for default router 3)
(Select VLAN 3)
(Select port for common server 1)
(Enable VLAN 3)
150 Chapter 8: Basic IP Routing 42C4911, January 2007
Alteon OS Application Guide
Each time you add a port to a VLAN, you may get the following prompt:
Port 4 is an untagged port and its current PVID is 1.
Confirm changing PVID from 1 to 2 [y/n]?
Enter y to set the default Port VLAN ID (PVID) for the port.
3.
Add each IP interface to the appropriate VLAN.
Now that the ports are separated into three VLANs, the IP interface for each subnet must be placed in the appropriate VLAN. From
Table 8-3 on page 150 , the settings are made as fol-
lows:
>> VLAN 3# /cfg/l3/if 1
>> IP Interface 1# vlan 2
>> IP Interface 1# ../if 2
>> IP Interface 2# vlan 1
>> IP Interface 2# ../if 3
>> IP Interface 3# vlan 1
>> IP Interface 3# ../if 4
>> IP Interface 4# vlan 3
(Select IP interface 1 for def. routers)
(Set to VLAN 2)
(Select IP interface 2 for first floor)
(Set to VLAN 1)
(Select IP interface 3 for second floor)
(Set to VLAN 1)
(Select IP interface 4 for servers)
(Set to VLAN 3)
4.
Apply and verify the configuration.
>> IP Interface 5# apply
>> IP Interface 5# /info/vlan
>> Information# port
(Make your changes active)
(View current VLAN information)
(View current port information)
Examine the resulting information. If any settings are incorrect, make the appropriate changes.
5.
Save your new configuration changes.
>> Information# save (Save for restore after reboot)
42C4911, January 2007 Chapter 8: Basic IP Routing 151
Alteon OS Application Guide
Dynamic Host Configuration Protocol
Dynamic Host Configuration Protocol (DHCP) is a transport protocol that provides a framework for automatically assigning IP addresses and configuration information to other IP hosts or clients in a large TCP/IP network. Without DHCP, the IP address must be entered manually for each network device. DHCP allows a network administrator to distribute IP addresses from a central point and automatically send a new IP address when a device is connected to a different place in the network.
DHCP is an extension of another network IP management protocol, Bootstrap Protocol
(BOOTP), with an additional capability of being able to dynamically allocate reusable network addresses and configuration parameters for client operation.
Built on the client/server model, DHCP allows hosts or clients on an IP network to obtain their configurations from a DHCP server, thereby reducing network administration. The most significant configuration the client receives from the server is its required IP address; (other optional parameters include the “generic” file name to be booted, the address of the default gateway, and so forth).
DHCP relay agent eliminates the need to have DHCP/BOOTP servers on every subnet. It allows the administrator to reduce the number of DHCP servers deployed on the network and to centralize them. Without the DHCP relay agent, there must be at least one DHCP server deployed at each subnet that has hosts needing to perform the DHCP request.
152 Chapter 8: Basic IP Routing 42C4911, January 2007
Alteon OS Application Guide
DHCP Relay Agent
DHCP is described in RFC 2131, and the DHCP relay agent supported on GbE Switch Modules is described in RFC 1542. DHCP uses UDP as its transport protocol. The client sends messages to the server on port 67 and the server sends messages to the client on port 68.
DHCP defines the methods through which clients can be assigned an IP address for a finite lease period and allowing reassignment of the IP address to another client later. Additionally,
DHCP provides the mechanism for a client to gather other IP configuration parameters it needs to operate in the TCP/IP network.
In the DHCP environment, the GbE Switch Module acts as a relay agent. The DHCP relay feature (/cfg/l3/bootp) enables the switch to forward a client request for an IP address to two BOOTP servers with IP addresses that have been configured on the switch.
When a switch receives a UDP broadcast on port 67 from a DHCP client requesting an IP address, the switch acts as a proxy for the client, replacing the client source IP (SIP) and destination IP (DIP) addresses. The request is then forwarded as a UDP Unicast MAC layer message to two BOOTP servers whose IP addresses are configured on the switch. The servers respond as a UDP Unicast message back to the switch, with the default gateway and IP address for the client. The destination IP address in the server response represents the interface address on the switch that received the client request. This interface address tells the switch on which
VLAN to send the server response to the client.
42C4911, January 2007 Chapter 8: Basic IP Routing 153
Alteon OS Application Guide
DHCP Relay Agent Configuration
To enable the GbE Switch Module to be the BOOTP forwarder, you need to configure the
DHCP/BOOTP server IP addresses on the switch. You generally configure the IP interface on the client side to match the client’s subnet, and configure VLANs to separate client and server subnets. The DHCP server knows from which IP subnet the newly allocated IP address should come.
The following figure shows a basic DHCP network example:
GbESM
DHCP
Server
Figure 8-3 DHCP Relay Agent Configuration
In GbE Switch Module implementation, there is no need for primary or secondary servers. The client request is forwarded to the BOOTP servers configured on the switch. The use of two servers provide failover redundancy. However, no health checking is supported.
Use the following commands to configure the switch as a DHCP relay agent:
>> # /cfg/l3/bootp
>> Bootstrap Protocol Relay# addr
>> Bootstrap Protocol Relay# addr2
>> Bootstrap Protocol Relay# on
>> Bootstrap Protocol Relay# off
>> Bootstrap Protocol Relay# cur
(Set IP address of BOOTP server)
(Set IP address of 2nd BOOTP server)
(Globally turn BOOTP relay on)
(Globally turn BOOTP relay off)
(Display current configuration)
Additionally, DHCP Relay functionality can be assigned on a per interface basis. Use the following command to enable the Relay functionality:
>> # /cfg/l3/if <interface number>/relay ena
154 Chapter 8: Basic IP Routing 42C4911, January 2007
C HAPTER 9
Routing Information Protocol
In a routed environment, routers communicate with one another to keep track of available routes. Routers can learn about available routes dynamically using the Routing Information
Protocol (RIP). Alteon OS software supports RIP version 1 (RIPv1) and RIP version 2 (RIPv2) for exchanging TCP/IP route information with other routers.
Distance Vector Protocol
RIP is known as a distance vector protocol. The vector is the network number and next hop, and the distance is the cost associated with the network number. RIP identifies network reachability based on cost, and cost is defined as hop count. One hop is considered to be the distance from one switch to the next which is typically 1. This cost or hop count is known as the metric.
When a switch receives a routing update that contains a new or changed destination network entry, the switch adds 1 to the metric value indicated in the update and enters the network in the routing table. The IP address of the sender is used as the next hop.
Stability
RIP includes a number of other stability features that are common to many routing protocols.
For example, RIP implements the split horizon and hold-down mechanisms to prevent incorrect routing information from being propagated.
RIP prevents routing loops from continuing indefinitely by implementing a limit on the number of hops allowed in a path from the source to a destination. The maximum number of hops in a path is 15. The network destination network is considered unreachable if increasing the metric value by 1 causes the metric to be 16 (that is infinity). This limits the maximum diameter of a RIP network to less than 16 hops.
RIP is often used in stub networks and in small autonomous systems that do not have many redundant paths.
42C4911, January 2007 155
Alteon OS Application Guide
Routing Updates
RIP sends routing-update messages at regular intervals and when the network topology changes. Each router “advertises” routing information by sending a routing information update every 30 seconds. If a router doesn’t receive an update from another router for 180 seconds, those routes provided by that router are declared invalid. After another 120 seconds without receiving an update for those routes, the routes are removed from the routing table and respective regular updates.
When a router receives a routing update that includes changes to an entry, it updates its routing table to reflect the new route. The metric value for the path is increased by 1, and the sender is indicated as the next hop. RIP routers maintain only the best route (the route with the lowest metric value) to a destination.
For more information see The Configuration Menu, Routing Information Protocol Configuration (/cfg/l3/rip) in the Alteon OS Command Reference.
RIPv1
RIP version 1 use broadcast User Datagram Protocol (UDP) data packets for the regular routing updates. The main disadvantage is that the routing updates do not carry subnet mask information. Hence, the router cannot determine whether the route is a subnet route or a host route.
It is of limited usage after the introduction of RIPv2. For more information about
RIPv1 and RIPv2, refer to RFC 1058 and RFC 2453.
RIPv2
RIPv2 is the most popular and preferred configuration for most networks. RIPv2 expands the amount of useful information carried in RIP messages and provides a measure of security. For a detailed explanation of RIPv2, refer to RFC 1723 and RFC 2453.
RIPv2 improves efficiency by using multicast UDP (address 224.0.0.9) data packets for regular routing updates. Subnet mask information is provided in the routing updates. A security option is added for authenticating routing updates, by using a shared password. Alteon OS supports using clear password for RIPv2.
156 Chapter 9: Routing Information Protocol 42C4911, January 2007
Alteon OS Application Guide
RIPv2 in RIPv1 compatibility mode
Alteon OS allows you to configure RIPv2 in RIPv1compatibility mode, for using both RIPv2 and RIPv1 routers within a network. In this mode, the regular routing updates use broadcast
UDP data packet to allow RIPv1 routers to receive those packets. With RIPv1 routers as recipients, the routing updates have to carry natural or host mask. Hence, it is not a recommended configuration for most network topologies.
N OTE – When using both RIPv1 and RIPv2 within a network, use a single subnet mask throughout the network.
RIP Features
Alteon OS provides the following features to support RIPv1 and RIPv2:
Poison
Simple split horizon in RIP scheme omits routes learned from one neighbor in updates sent to that neighbor. That is the most common configuration used in RIP, that is setting this Poison to
DISABLE. Split horizon with poisoned reverse includes such routes in updates, but sets their metrics to 16. The disadvantage of using this feature is the increase of size in the routing updates.
Triggered updates
Triggered updates are an attempt to speed up convergence. When Triggered Updates is enabled
(/cfg/l3/rip/if x/trigg/e), whenever a router changes the metric for a route, it sends update messages almost immediately, without waiting for the regular update interval. It is recommended to enable Triggered Updates.
Multicast
RIPv2 messages use IP multicast address (224.0.0.9) for periodic broadcasts. Multicast RIPv2 announcements are not processed by RIPv1 routers. IGMP is not needed since these are interrouter messages which are not forwarded.
To configure RIPv2 in RIPv1 compatibility mode, set multicast to disable, and set version to both.
42C4911, January 2007 Chapter 9: Routing Information Protocol 157
Alteon OS Application Guide
Default
The RIP router can listen and supply a default route, usually represented as 0.0.0.0 in the routing table. When a router does not have an explicit route to a destination network in its routing table, it uses the default route to forward those packets.
Metric
The metric field contains a configurable value between 1 and 15 (inclusive) which specifies the current metric for the interface. The metric value typically indicates the total number of hops to the destination. The metric value of 16 represents an unreachable destination.
Authentication
RIPv2 authentication uses plaintext password for authentication. If configured using Authentication password, then it is necessary to enter an authentication key value.
The following method is used to authenticate a RIP message:
If the router is not configured to authenticate RIPv2 messages, then RIPv1 and unauthenticated RIPv2 messages are accepted; authenticated RIPv2 messages are discarded.
If the router is configured to authenticate RIPv2 messages, then RIPv1 messages and
RIPv2 messages which pass authentication testing are accepted; unauthenticated and failed authentication RIPv2 messages are discarded.
For maximum security, RIPv1 messages are ignored when authentication is enabled
(cfg/l3/rip/if x/auth/password); otherwise, the routing information from authenticated messages is propagated by RIPv1 routers in an unauthenticated manner.
RIP Configuration Example
N OTE – An interface RIP disabled uses all the default values of the RIP, no matter how the
RIP parameters are configured for that interface. RIP sends out RIP regular updates to include an UP interface, but not a DOWN interface.
158 Chapter 9: Routing Information Protocol 42C4911, January 2007
Alteon OS Application Guide
1.
Add VLANs for routing interfaces.
>> Main# cfg/l2/vlan 2/ena
>> VLAN 2# add ext2
(Enable VLAN 2)
(Add port EXT2 to VLAN 2)
Port EXT2 is an UNTAGGED port and its current PVID is 1.
Confirm changing PVID from 1 to 2 [y/n]: y
>> VLAN 2# /cfg/l2/vlan 3/ena
>> VLAN 3# add ext3
(Enable VLAN 3)
(Add port EXT3 to VLAN 3)
Port EXT3 is an UNTAGGED port and its current PVID is 1.
Confirm changing PVID from 1 to 3 [y/n]: y
2.
Add IP interfaces to VLANs.
>> Main# cfg/l3/if 2/ena
>> IP Interface 2# addr 102.1.1.1
>> IP Interface 2# vlan 2
>> IP Interface 2# /cfg/l3/if 3/ena
>> IP Interface 3# addr 103.1.1.1
>> IP Interface 3# vlan 3
(Enable interface 2)
(Define IP address for interface 2)
(Add interface 2 to VLAN 2)
(Enable interface 3)
(Define IP address for interface 3)
(Add interface 3 to VLAN 3)
3.
Turn on RIP globally and enable RIP for each interface.
>> Main# cfg/l3/rip on (Turn on RIP globally)
>> Routing Information Protocol# if 2/ena (Enable RIP on IP interface 2)
>> RIP Interface 2# ..
>> Routing Information Protocol# if 3/ena (Enable RIP on IP interface 3)
>> RIP Interface 3# apply (Apply your changes)
>> RIP Interface 3# save (Save the configuration)
Use the /maint/route/dump command to check the current valid routes in the routing table of the switch.
For those RIP learnt routes within the garbage collection period, that are routes phasing out of the routing table with metric 16, use the /info/l3/rip/routes command. Locally configured static routes do not appear in the RIP Routes table.
42C4911, January 2007 Chapter 9: Routing Information Protocol 159
Alteon OS Application Guide
160 Chapter 9: Routing Information Protocol 42C4911, January 2007
C HAPTER 10
IGMP
Internet Group Management Protocol (IGMP) is used by IP Multicast routers to learn about the existence of host group members on their directly attached subnet (see RFC 2236). The IP
Multicast routers get this information by broadcasting IGMP Membership Queries and listening for IP hosts reporting their host group memberships. This process is used to set up a client/ server relationship between an IP Multicast source that provides the data streams and the clients that want to receive the data.
The GbESM can perform IGMP Snooping, or act as an IGMP Relay (proxy) device.
The following topics are discussed in this chapter:
“Additional IGMP Features” on page 168
42C4911, January 2007 161
Alteon OS Application Guide
IGMP Snooping
IGMP Snooping allows the switch to forward multicast traffic only to those ports that request it. IGMP Snooping prevents multicast traffic from being flooded to all ports. The switch learns which server hosts are interested in receiving multicast traffic, and forwards it only to ports connected to those servers.
IGMP Snooping conserves bandwidth. With IGMP Snooping, the switch learns which ports are interested in receiving multicast data, and forwards multicast data only to those ports. In this way, other ports are not burdened with unwanted multicast traffic.
The switch can sense IGMP Membership Reports from attached clients and act as a proxy to set up a dedicated path between the requesting host and a local IP Multicast router. After the pathway is established, the switch blocks the IP Multicast stream from flowing through any port that does not connect to a host member, thus conserving bandwidth.
The client-server path is set up as follows:
An IP Multicast Router (Mrouter) sends Membership Queries to the switch, which forwards them to all ports in a given VLAN.
Hosts that want to receive the multicast data stream send Membership Reports to the switch, which sends a proxy Membership Report to the Mrouter.
The switch sets up a path between the Mrouter and the host, and blocks all other ports from receiving the multicast.
Periodically, the Mrouter sends Membership Queries to ensure that the host wants to continue receiving the multicast. If a host fails to respond with a Membership Report, the
Mrouter stops sending the multicast to that path.
The host can send a Leave Report to the switch, which sends a proxy Leave Report to the
Mrouter. The multicast path is terminated immediately.
162 Chapter 10: IGMP 42C4911, January 2007
Alteon OS Application Guide
IGMP Snooping Configuration Example
This section provides steps to configure IGMP Snooping on the GbESM, using the Command-
Line Interface (CLI).
Configure IGMP Snooping
1.
Configure port and VLAN membership on the switch.
2.
Turn on IGMP.
>> /cfg/l3/igmp/on (Turn on IGMP)
3.
Add VLANs to IGMP Snooping and enable the feature.
>> /cfg/l3/igmp/snoop
>> IGMP Snoop# add 1
>> IGMP Snoop# ena
(Access IGMP Snoop menu)
(Add VLAN 1 to IGMP snooping)
(Enable IGMP Snooping)
4.
Apply and save the configuration.
>> IGMP Snoop# apply
>> IGMP Snoop# save
(Apply the configuration)
(Save your changes)
5.
View dynamic IGMP information.
>> /info/l3/igmp
>> IGMP Multicast Group# dump
(Select IGMP information menu)
(Show IGMP Group information)
>> IGMP Multicast# dump
Note: Local groups (224.0.0.x) are not snooped and will not appear.
Group VLAN Port Version Expires
--------------- ------ ------- -------- ----------
238.1.0.0 1 EXT1 V2 4:17
238.1.0.4 1 EXT1 V2 4:18
>> /info/l3/igmp/mrouter
>> Mrouter# dump
(Select Mrouter information menu)
(Show IGMP Group information)
>> IGMP Multicast Router# dump
VLAN Port Version Expires Max Query Resp. Time
------- ------- --------- -------- -----------------------
1 EXT4 V2 static unknown
42C4911, January 2007 Chapter 10: IGMP 163
Alteon OS Application Guide
These commands display information about IGMP Groups and Mrouters learned through
IGMP Snooping.
Static Multicast Router
A static multicast router (Mrouter) can be configured for a particular port on a particular
VLAN. A static Mrouter does not have to be learned through IGMP Snooping.
A total of 16 static Mrouters can be configured on the GbESM. Both internal and external ports can accept a static Mrouter.
When you configure a static Mrouter on a VLAN, it replaces any dynamic Mrouters learned through IGMP Snooping.
Configure a Static Multicast Router
1.
Configure a port to which the static Multicast Router is connected, and enter the appropriate VLAN.
>> /cfg/l3/igmp/mrouter (Select IGMP Mrouter menu)
>> Static Multicast Router# add EXT4 (Add port EXT4 as Static Mrouter port)
Enter VLAN number: (1-4093) 1 (Enter the VLAN number)
Enter the version number of mrouter [1|2]: 2 (Enter the IGMP version number)
2.
Apply, verify, and save the configuration.
>> Static Multicast Router# apply
>> Static Multicast Router# cur
>> Static Multicast Router# save
(Apply the configuration)
(View the configuration)
(Save your changes)
164 Chapter 10: IGMP 42C4911, January 2007
Alteon OS Application Guide
IGMP Relay
The GbESM can act as an IGMP Relay (or IGMP Proxy) device that relays IGMP multicast messages and traffic between an Mrouter and end stations. IGMP Relay allows the GbESM to participate in network multicasts with no configuration of the various multicast routing protocols, so you can deploy it in the network with minimal effort.
To an IGMP host connected to the GbESM, IGMP Relay appears to be an IGMP multicast router (Mrouter). IGMP Relay sends Membership Queries to hosts, which respond by sending an IGMP response message. A host can also send an unsolicited Join message to the IGMP
Relay.
To a multicast router, IGMP Relay appears as a host. The Mrouter sends IGMP host queries to
IGMP Relay, and IGMP Relay responds by forwarding IGMP host reports and unsolicited join messages from its attached hosts.
IGMP Relay also forwards multicast traffic between the Mrouter and end stations, similar to IGMP Snooping.
You can configure up to two Mrouters to use with IGMP Relay. One Mrouter acts as the primary Mrouter, and one is the backup Mrouter. The GbESM uses health checks to select the primary Mrouter.
Configuration Guidelines
Consider the following guidelines when you configure IGMP Relay:
IGMP Relay and IGMP Snooping are mutually exclusive—if you enable IGMP Relay, you must turn off IGMP Snooping.
Upstream Mrouters must be connected to external ports (EXT 1 - EXT 6).
42C4911, January 2007 Chapter 10: IGMP 165
Alteon OS Application Guide
Configure IGMP Relay
Use the following procedure to configure IGMP Relay.
1.
Configure an IP interface and assign VLANs.
>> /cfg/l3/if 2
>> IP Interface 2# addr 10.10.1.1
>> IP Interface 2# mask 255.255.255.0
>> IP Interface 2# vlan 2
>> /cfg/l3/if 3
>> IP Interface 3# addr 10.10.1.2
>> IP Interface 3# mask 255.255.255.0
>> IP Interface 3# vlan 3
(Select IP interface 2)
(Configure IP address for IF 2)
(Configure mask for IF 2)
(Assign VLAN 2 to IF 2)
(Select IP interface 3)
(Configure IP address for IF 3)
(Configure mask for IF 3)
(Assign VLAN 3 to IF 3)
2.
Turn IGMP on.
>> /cfg/l3/igmp/on (Turn on IGMP)
3.
Enable IGMP Relay and add VLANs to the downstream network.
>> /cfg/l3/igmp/relay/ena (Enable IGMP Relay)
>> IGMP Relay# add 2
Vlan 2 added.
(Add VLAN 2 to IGMP Relay)
>> IGMP Relay# add 3 (Add VLAN 3 to IGMP Relay)
Vlan 3 added.
4.
Configure the upstream Mrouters.
>> IGMP Relay# mrtr 1/addr 100.0.1.2/ena
Current IP address: 0.0.0.0
New pending IP address: 100.0.1.2
Current status: disabled
New status: enabled
>> Multicast router 1# ..
>> IGMP Relay# mrtr 2/addr 100.0.2.4/ena
Current IP address: 0.0.0.0
New pending IP address: 100.0.2.4
Current status: disabled
New status: enabled
166 Chapter 10: IGMP 42C4911, January 2007
5.
Apply and save the configuration.
>> Multicast router 2# apply
>> Multicast router 2# save
Alteon OS Application Guide
(Apply the configuration)
(Save the configuration)
42C4911, January 2007 Chapter 10: IGMP 167
Alteon OS Application Guide
Additional IGMP Features
The following topics are discussed in this section:
FastLeave
In normal IGMP operation, when the receives an IGMPv2 leave message, it sends a Group-
Specific Query to determine if any other devices in the same group (and on the same port) are still interested in the specified multicast group traffic. The switch removes the affiliated port from that particular group, if the following conditions apply:
If the switch does not receive an IGMP Membership Report within the query-responseinterval.
If no multicast routers have been learned on that port.
With FastLeave enabled on the VLAN, a port can be removed immediately from the port list of the group entry when the IGMP Leave message is received, unless a multicast router was learned on the port.
Enable FastLeave only on VLANs that have only one host connected to each physical port.
IGMP Filtering
With IGMP Filtering, you can allow or deny a port to send and receive multicast traffic to certain multicast groups. Unauthorized users are restricted from streaming multicast traffic across the network.
If access to a multicast group is denied, IGMP Membership Reports from the port are dropped, and the port is not allowed to receive IP multicast traffic from that group. If access to the multicast group is allowed, Membership Reports from the port are forwarded for normal processing.
To configure IGMP Filtering, you must globally enable IGMP filtering, define an IGMP filter, assign the filter to a port, and enable IGMP Filtering on the port. To define an IGMP filter, you must configure a range of IP multicast groups, choose whether the filter will allow or deny multicast traffic for groups within the range, and enable the filter.
Configuring the Range
168 Chapter 10: IGMP 42C4911, January 2007
Alteon OS Application Guide
Each IGMP Filter allows you to set a start and end point that defines the range of IP addresses upon which the filter takes action. Each IP address in the range must be between 224.0.1.0 and
239.255.255.255. If you choose any as the start point, then the filter acts upon all addresses between 224.0.0.0 and the address entered as the end point. If you enter any as the end point, then the filter acts upon all addresses between the address entered as the start point and
239.255.255.255.
Configuring the Action
Each IGMP filter can allow or deny IP multicasts to the range of IP addresses configured. If you configure the filter to deny IP multicasts, then IGMP Membership Reports from multicast groups within the range are dropped. You can configure a secondary filter to allow IP multicasts to a small range of addresses within a larger range that a primary filter is configured to deny. The two filters work together to allow IP multicasts to a small subset of addresses within the larger range of addresses.
Configure IGMP Filtering
1.
Enable IGMP Filtering on the switch.
>> /cfg/l3/igmp/igmpflt
>> IGMP Filter# ena
Current status: disabled
New status: enabled
(Select IGMP Filtering menu)
(Enable IGMP Filtering)
2.
Define an IGMP filter.
>> /cfg/l3/igmp/igmpflt (Select IGMP Filtering menu)
>>IGMP Filter# filter 1 (Select Filter 1 Definition menu)
>>IGMP Filter 1 Definition# range 224.0.1.0 (Enter first IP address of the range)
Current multicast address2: any
Enter new multicast address2 or any: 226.0.0.0 (Enter second IP address)
Current multicast address1: any
New pending multicast address1: 224.0.1.0
Current multicast address2: any
New pending multicast address2: 226.0.0.0
>>IGMP Filter 1 Definition# action deny
>>IGMP Filter 1 Definition# ena
(Deny multicast traffic)
(Enable the filter)
42C4911, January 2007 Chapter 10: IGMP 169
Alteon OS Application Guide
3.
Assign the IGMP filter to a port.
>> /cfg/l3/igmp/igmpflt
>>IGMP Filter# port EXT3
>>IGMP Port EXT3# filt ena
Current port EXT3 filtering: disabled
New port EXT3 filtering: enabled
>>IGMP Port EXT3# add 1
>>IGMP Port EXT3# apply
(Select IGMP Filtering menu)
(Select port EXT3)
(Enable IGMP Filtering on the port)
(Add IGMP Filter 1 to the port)
(Make your changes active)
170 Chapter 10: IGMP 42C4911, January 2007
C HAPTER 11
Border Gateway Protocol
Border Gateway Protocol (BGP) is an Internet protocol that enables routers on a network to share and advertise routing information with each other about the segments of the IP address space they can access within their network and with routers on external networks. BGP allows you to decide what is the “best” route for a packet to take from your network to a destination on another network rather than simply setting a default route from your border router(s) to your upstream provider(s). BGP is defined in RFC 1771.
GbE Switch Modules can advertise their IP interfaces and IP addresses using BGP and take
BGP feeds from as many as 16 BGP router peers. This allows more resilience and flexibility in balancing traffic from the Internet.
The following topics are discussed in this section:
“Internal Routing Versus External Routing” on page 172
“Forming BGP Peer Routers” on page 173
“What is a Route Map?” on page 174
“Aggregating Routes” on page 178
“Redistributing Routes” on page 179
“Selecting Route Paths in BGP” on page 181
“BGP Failover Configuration” on page 182
“Default Redistribution and Route Aggregation Example” on page 185
42C4911, January 2007 171
Alteon OS Application Guide
Internal Routing Versus External Routing
To ensure effective processing of network traffic, every router on your network needs to know how to send a packet (directly or indirectly) to any other location/destination in your network.
This is referred to as internal routing and can be done with static routes or using active, internal dynamic routing protocols, such as RIP, RIPv2, and OSPF.
Static routes should have a higher degree of precedence than dynamic routing protocols. If the destination route is not in the route cache, then the packets are forwarded to the default gateway which may be incorrect if a dynamic routing protocol is enabled.
It is also useful to tell routers outside your network (upstream providers or peers) about the routes you can access in your network. External networks (those outside your own) that are under the same administrative control are referred to as autonomous systems (AS). Sharing of routing information between autonomous systems is known as external routing.
External BGP (eBGP) is used to exchange routes between different autonomous systems whereas internal BGP (iBGP) is used to exchange routes within the same autonomous system.
An iBGP is a type of internal routing protocol you can use to do active routing inside your network. It also carries AS path information, which is important when you are an ISP or doing
BGP transit.
N OTE
– The iBGP peers must be part of a fully meshed network, as shown in Figure 11-1
.
Figure 11-1 iBGP and eBGP
172 Chapter 11: Border Gateway Protocol 42C4911, January 2007
Alteon OS Application Guide
Typically, an AS has one or more border routers—peer routers that exchange routes with other
ASs—and an internal routing scheme that enables routers in that AS to reach every other router and destination within that AS. When you advertise routes to border routers on other autonomous systems, you are effectively committing to carry data to the IP space represented in the route being advertised. For example, if you advertise 192.204.4.0/24, you are declaring that if another router sends you data destined for any address in 192.204.4.0/24, you know how to carry that data to its destination.
Forming BGP Peer Routers
Two BGP routers become peers or neighbors once you establish a TCP connection between them. For each new route, if a peer is interested in that route (for example, if a peer would like to receive your static routes and the new route is static), an update message is sent to that peer containing the new route. For each route removed from the route table, if the route has already been sent to a peer, an update message containing the route to withdraw is sent to that peer.
For each Internet host, you must be able to send a packet to that host, and that host has to have a path back to you. This means that whoever provides Internet connectivity to that host must have a path to you. Ultimately, this means that they must “hear a route” which covers the section of the
IP space you are using; otherwise, you will not have connectivity to the host in question.
42C4911, January 2007 Chapter 11: Border Gateway Protocol 173
Alteon OS Application Guide
What is a Route Map?
A route map is used to control and modify routing information. Route maps define conditions for redistributing routes from one routing protocol to another or controlling routing information when injecting it in and out of BGP. Route maps are used by OSPF only for redistributing routes. For example, a route map is used to set a preference value for a specific route from a peer router and another preference value for all other routes learned via the same peer router.
For example, the following command is used to define a route map:
>> # /cfg/l3/rmap 1 (Select a route map)
A route map allows you to match attributes, such as metric, network address, and AS number.
It also allows users to overwrite the local preference metric and to append the AS number in the AS route. See
“BGP Failover Configuration” on page 182 .
Alteon OS allows you to configure 32 route maps. Each route map can have up to eight access lists. Each access list consists of a network filter. A network filter defines an IP address and
subnet mask of the network that you want to include in the filter. Figure 11-2
illustrates the relationship between route maps, access lists and network filters.
174 Chapter 11: Border Gateway Protocol 42C4911, January 2007
Alteon OS Application Guide
Route Maps
(rmap)
Access Lists
(alist)
Network Filter
(nwf)
1
Route Map 1
1
---
---
---
8 8
Route Map 2
1
---
---
---
8
9
16
-----
-----
-----
-----
-----
-----
-----
Route Map 32
1
---
---
---
8
249
256
Figure 11-2 Distributing Network Filters in Access Lists and Route Maps
Incoming and Outgoing Route Maps
You can have two types of route maps: incoming and outgoing. A BGP peer router can be configured to support up to eight route maps in the incoming route map list and outgoing route map list.
If a route map is not configured in the incoming route map list, the router imports all BGP updates. If a route map is configured in the incoming route map list, the router ignores all unmatched incoming updates. If you set the action to deny, you must add another route map to permit all unmatched updates.
Route maps in an outgoing route map list behave similar to route maps in an incoming route map list. If a route map is not configured in the outgoing route map list, all routes are advertised or permitted. If a route map in the outgoing route map list is set to permit, matched routes are advertised and unmatched routes are ignored.
42C4911, January 2007 Chapter 11: Border Gateway Protocol 175
Alteon OS Application Guide
Precedence
You can set a priority to a route map by specifying a precedence value with the following command:
>> /cfg/l3/rmap <x>/pre (Specify a precedence)
The smaller the value the higher the precedence. If two route maps have the same precedence value, the smaller number has higher precedence.
Configuration Overview
To configure route maps, you need to do the following:
1.
Define network filter.
>> # /cfg/l3/nwf 1 (Specify a network filter number)
>> IP Network Filter 1# addr <IP address> (Specify network address)
>> IP Network Filter 1# mask <IP mask> (Specify network mask)
>> IP Network Filter 1# ena (Enable network filter)
Enter a filter number from 1 to 256. Specify the IP address and subnet mask of the network that you want to match. Enable the network filter. You can distribute up to 256 network filters among 32 route maps each containing eight access lists.
2.
(Optional) Define the criteria for the access list and enable it.
Specify the access list and associate the network filter number configured in Step 1.
>> # /cfg/l3/rmap 1
>> IP Route Map 1# alist 1
>> IP Access List 1# nwf 1
>> IP Access List 1# metric
>> IP Access List 1# action deny
>> IP Access List 1# ena
(Specify a route map number)
(Specify the access list number)
(Specify the network filter number)
(Define a metric)
(Specify action for the access list)
(Enable the access list)
Steps 2 and 3 are optional, depending on the criteria that you want to match. In Step 2, the network filter number is used to match the subnets defined in the network filter. In Step 3, the autonomous system number is used to match the subnets. Or, you can use both (Step 2 and Step
3) criteria: access list (network filter) and access path (AS filter) to configure the route maps.
176 Chapter 11: Border Gateway Protocol 42C4911, January 2007
Alteon OS Application Guide
3.
(Optional) Configure the attributes in the AS filter menu.
>> # cfg/l3/rmap 1/aspath 1
>> AS Filter 1#
>> AS Filter 1#
>> AS Filter 1#
as 1
action deny
ena
(Specify the attributes in the filter)
(Specify the AS number)
(Specify the action for the filter)
(Enable the AS filter)
4.
Set up the BGP attributes.
If you want to overwrite the attributes that the peer router is sending, then define the following
BGP attributes:
Specify the AS numbers that you want to prepend to a matched route and the local preference for the matched route.
Specify the metric [Multi Exit Discriminator (MED)] for the matched route.
>> # cfg/l3/rmap 1
>> IP Route Map 1# ap
>> IP Route Map 1# lp
>> IP Route Map 1# met
(Specify a route map number)
(Specify the AS numbers to prepend)
(Specify the local preference)
(Specify the metric)
5.
Enable the route map.
>> # cfg/l3/rmap 1/en (Enable the route map)
6.
Assign the route map to a peer router.
Select the peer router and then add the route map to the incoming route map list,
>> # cfg/l3/bgp/peer 1/addi (Add to the incoming route map)
or to the outgoing route map list.
>> # cfg/l3/bgp/peer 1/addo (Add to the outgoing route map)
42C4911, January 2007 Chapter 11: Border Gateway Protocol 177
Alteon OS Application Guide
Aggregating Routes
Aggregation is the process of combining several different routes in such a way that a single route can be advertised, which minimizes the size of the routing table. You can configure aggregate routes in BGP either by redistributing an aggregate route into BGP or by creating an aggregate entry in the BGP routing table.
When a subnet is redistributed from an Interior Gateway Protocol (IGP) into BGP, only the network route is injected into the BGP table. By default, this automatic summarization is disabled. To define the route to aggregate, use the following commands:
>> # cfg/l3/bgp
>> Border Gateway Protocol# aggr 1
>> BGP aggr 1 # addr
>> BGP aggr 1 # mask
>> BGP aggr 1 # ena
(Specify BGP)
(Specify aggregate list number)
(Enter aggregation network address)
(Enter aggregation network mask)
(Enable aggregation)
An example of creating a BGP aggregate route is shown in
“Default Redistribution and Route
Aggregation Example” on page 185 .
178 Chapter 11: Border Gateway Protocol 42C4911, January 2007
Alteon OS Application Guide
Redistributing Routes
In addition to running multiple routing protocols simultaneously, Alteon OS software can redistribute information from one routing protocol to another. For example, you can instruct the switch to use BGP to readvertise static routes. This applies to all of the IP-based routing protocols.
You can also conditionally control the redistribution of routes between routing domains by defining a method known as route maps between the two domains. For more information on route maps, see
“What is a Route Map?” on page 174
. Redistributing routes is another way of providing policy control over whether to export OSPF routes, fixed routes, static routes, and
virtual IP address routes. For an example configuration, see “Default Redistribution and Route
Aggregation Example” on page 185 .
Default routes can be configured using the following methods:
Import
Originate—The router sends a default route to peers if it does not have any default routes in its routing table.
Redistribute—Default routes are either configured through the default gateway or learned via other protocols and redistributed to peer routers. If the default routes are from the default gateway, enable the static routes because default routes from the default gateway are static routes. Similarly, if the routes are learned from another routing protocol, make sure you enable that protocol for redistribution.
None
42C4911, January 2007 Chapter 11: Border Gateway Protocol 179
Alteon OS Application Guide
BGP Attributes
The following two BGP attributes are discussed in this section: Local preference and metric
(Multi-Exit Discriminator).
Local Preference Attribute
When there are multiple paths to the same destination, the local preference attribute indicates the preferred path. The path with the higher preference is preferred (the default value of the local preference attribute is 100). Unlike the weight attribute, which is only relevant to the local router, the local preference attribute is part of the routing update and is exchanged among routers in the same AS.
The local preference attribute can be set in one of two ways:
/cfg/l3/bgp/pref
This command uses the BGP default local preference method, affecting the outbound direction only.
/cfg/l3/rmap/lp
This command uses the route map local preference method, which affects both inbound and outbound directions.
Metric (Multi-Exit Discriminator) Attribute
This attribute is a hint to external neighbors about the preferred path into an AS when there are multiple entry points. A lower metric value is preferred over a higher metric value. The default value of the metric attribute is 0.
Unlike local preference, the metric attribute is exchanged between ASs; however, a metric attribute that comes into an AS does not leave the AS.
When an update enters the AS with a certain metric value, that value is used for decision making within the AS. When BGP sends that update to another AS, the metric is reset to 0.
Unless otherwise specified, the router compares metric attributes for paths from external neighbors that are in the same AS.
180 Chapter 11: Border Gateway Protocol 42C4911, January 2007
Alteon OS Application Guide
Selecting Route Paths in BGP
BGP selects only one path as the best path. It does not rely on metrics attributes to determine the best path. When the same network is learned via more than one BGP peer, BGP uses its policy for selecting the best route to that network. The BGP implementation on the GbE
Switch Module uses the following criteria to select a path when the same route is received from multiple peers.
1.
Local fixed and static routes are preferred over learned routes.
2.
With iBGP peers, routes with higher local preference values are selected.
3.
In the case of multiple routes of equal preference, the route with lower AS path weight is selected.
AS path weight = 128 x AS path length (number of autonomous systems transversed).
4.
In the case of equal weight and routes learned from peers that reside in the same AS, the lower metric is selected.
N OTE – A route with a metric is preferred over a route without a metric.
5.
The lower cost to the next hop of routes is selected.
6.
In the case of equal cost, the eBGP route is preferred over iBGP.
7.
If all routes are from eBGP, the route with the lower router ID is selected.
When the path is selected, BGP puts the selected path in its routing table and propagates the path to its neighbors.
42C4911, January 2007 Chapter 11: Border Gateway Protocol 181
Alteon OS Application Guide
BGP Failover Configuration
Use the following example to create redundant default gateways for a GbE Switch Module at a
Web Host/ISP site, eliminating the possibility, should one gateway go down, that requests will be forwarded to an upstream router unknown to the switch.
As shown in
, the switch is connected to ISP 1 and ISP 2. The customer negotiates with both ISPs to allow the switch to use their peer routers as default gateways. The ISP peer routers will then need to announce themselves as default gateways to the GbE Switch Module.
Server 1
IP: 200.200.200.10
Server 2
IP: 200.200.200.11
Figure 11-3 BGP Failover Configuration Example
On the GbE Switch Module, one peer router (the secondary one) is configured with a longer
AS path than the other, so that the peer with the shorter AS path will be seen by the switch as the primary default gateway. ISP 2, the secondary peer, is configured with a metric of “3,” thereby appearing to the switch to be three router hops away.
182 Chapter 11: Border Gateway Protocol 42C4911, January 2007
Alteon OS Application Guide
1.
Define the VLANs.
For simplicity, both default gateways are configured in the same VLAN in this example. The gateways could be in the same VLAN or different VLANs
.
>> # /cfg/l2/vlan 1
>> vlan 1# add < port number>
(Select VLAN 1)
(Add a port to the VLAN membership)
2.
Define the IP interfaces.
The switch will need an IP interface for each default gateway to which it will be connected.
Each interface will need to be placed in the appropriate VLAN. These interfaces will be used as the primary and secondary default gateways for the switch.
>> IP# metrc strict
>> IP# if 1
>> IP Interface 1# ena
>> IP Interface 1# addr 200.200.200.1
>> IP Interface 1# mask 255.255.255.0
>> IP Interface 1# ../ip/if 2
>> IP Interface 2# ena
>> IP Interface 2# addr 210.210.210.1
>> IP Interface 2# mask 255.255.255.0
(Set metric for default gateway)
(Select default gateway interface 1)
(Enable switch interface 1)
(Configure IP address of interface 1)
(Configure IP subnet address mask)
(Select default gateway interface 2)
(Enable switch interface 2)
(Configure IP address of interface 2)
(Configure IP subnet address mask)
3.
Enable IP forwarding.
IP forwarding is turned on by default and is used for VLAN-to-VLAN (non-BGP) routing.
Make sure IP forwarding is on if the default gateways are on different subnets or if the switch is connected to different subnets and those subnets need to communicate through the switch
(which they almost always do).
>> /cfg/l3/frwd on (Enable IP forwarding)
N OTE – To help eliminate the possibility for a Denial of Service (DoS) attack, the forwarding of directed broadcasts is disabled by default.
42C4911, January 2007 Chapter 11: Border Gateway Protocol 183
Alteon OS Application Guide
4.
Configure BGP peer router 1 and 2.
Peer 1 is the primary gateway router. Peer 2 is configured with a metric of “3.” The metric option is key to ensuring gateway traffic is directed to Peer 1, as it will make Peer 2 appear to be three router hops away from the switch. Thus, the switch should never use it unless Peer 1 goes down.
>> # /cfg/l3/bgp/peer 1
>> BGP Peer 1# ena
>> BGP Peer 1# addr 200.200.200.2
>> BGP Peer 1# if 200.200.200.1
>> BGP Peer 1# ras 100
>> BGP Peer 1# /cfg/l3/bgp/peer 2
>> BGP Peer 2# ena
>> BGP Peer 2# addr 210.210.210.2
>> BGP Peer 2# if 210.210.210.1
>> BGP Peer 2# ras 200
>> BGP Peer 2# metric 3
(Select BGP peer router 1)
(Enable this peer configuration)
(Set IP address for peer router 1)
(Set IP interface for peer router 1)
(Set remote AS number)
(Select BGP peer router 2)
(Enable this peer configuration)
(Set IP address for peer router 2)
(Set IP interface for peer router 2)
(Set remote AS number)
(Set AS path length to 3 router hops)
The metric command in the peer menu tells the GbE Switch Module to create an AS path of
“3” when advertising via BGP.
5.
On the switch, apply and save your configuration changes.
>> BGP Peer 2# apply
>> save
(Make your changes active)
(Save for restore after reboot)
184 Chapter 11: Border Gateway Protocol 42C4911, January 2007
Alteon OS Application Guide
Default Redistribution and Route Aggregation
Example
This example shows you how to configure the switch to redistribute information from one routing protocol to another and create an aggregate route entry in the BGP routing table to minimize the size of the routing table.
As illustrated in
, you have two peer routers: an internal and an external peer router.
Configure the GbE Switch Module to redistribute the default routes from AS 200 to AS 135.
At the same time, configure for route aggregation to allow you to condense the number of routes traversing from AS 135 to AS 200.
Figure 11-4 Route Aggregation and Default Route Redistribution
1.
Configure the IP interface.
2.
Configure the AS number (AS 135) and router ID number (10.1.1.135) .
>> # /cfg/l3/bgp
>> Border Gateway Protocol# as 135
(Select BGP menu)
(Specify an AS number)
>> Border Gateway Protocol# .. /rtrid 10.1.1.135 (Specify a router ID number)
42C4911, January 2007 Chapter 11: Border Gateway Protocol 185
Alteon OS Application Guide
3.
Configure internal peer router 1 and external peer router 2.
>> # /cfg/l3/bgp/peer 1
>> BGP Peer 1# ena
>> BGP Peer 1# addr 10.1.1.4
>> BGP Peer 1# ras 135
>> BGP Peer 1# ../peer 2
>> BGP Peer 2# ena
>> BGP Peer 2# addr 20.20.20.2
>> BGP Peer 2# ras 200
(Select internal peer router 1)
(Enable this peer configuration)
(Set IP address for peer router 1)
(Set remote AS number)
(Select external peer router 2)
(Enable this peer configuration)
(Set IP address for peer router 2)
(Set remote AS number)
4.
Configure redistribution for Peer 1.
>> # /cfg/l3/bgp/peer 1/redist
>> BGP Peer 1# default redistribute
>> BGP Peer 1# fixed ena
(Select redistribute)
(Set default to redistribute)
(Enable fixed routes)
5.
Configure aggregation policy control.
Configure the routes that you want aggregated.
>> # /cfg/l3/bgp/aggr 1
>> BGP aggr 1# addr 135.0.0.0
>> BGP Peer 1# mask 255.0.0.0
(Set aggregation number)
(Add IP address to aggregate 1)
(Add IP mask to aggregate 1)
186 Chapter 11: Border Gateway Protocol 42C4911, January 2007
C HAPTER 12
OSPF
Alteon OS supports the Open Shortest Path First (OSPF) routing protocol. The Alteon OS implementation conforms to the OSPF version 2 specifications detailed in Internet RFC 1583.
The following sections discuss OSPF support for the GbE Switch Module:
“OSPF Overview” on page 188 . This section provides information on OSPF concepts,
such as types of OSPF areas, types of routing devices, neighbors, adjacencies, link state database, authentication, and internal versus external routing.
“OSPF Implementation in Alteon OS” on page 193 . This section describes how OSPF is
implemented in Alteon OS, such as configuration parameters, electing the designated router, summarizing routes, defining route maps and so forth.
“OSPF Configuration Examples” on page 204 . This section provides step-by-step instruc-
tions on configuring different configuration examples:
Creating a simple OSPF domain
Creating virtual links
Summarizing routes
42C4911, January 2007 187
Alteon OS Application Guide
OSPF Overview
OSPF is designed for routing traffic within a single IP domain called an Autonomous System
(AS). The AS can be divided into smaller logical units known as areas.
All routing devices maintain link information in their own Link State Database (LSDB). The
LSDB for all routing devices within an area is identical but is not exchanged between different areas. Only routing updates are exchanged between areas, thereby significantly reducing the overhead for maintaining routing information on a large, dynamic network.
The following sections describe key OSPF concepts.
Types of OSPF Areas
An AS can be broken into logical units known as areas. In any AS with multiple areas, one area must be designated as area 0, known as the backbone. The backbone acts as the central
OSPF area. All other areas in the AS must be connected to the backbone. Areas inject summary routing information into the backbone, which then distributes it to other areas as needed.
As shown in
, OSPF defines the following types of areas:
Stub Area—an area that is connected to only one other area. External route information is not distributed into stub areas.
Not-So-Stubby-Area (NSSA)—similar to a stub area with additional capabilities. Routes originating from within the NSSA can be propagated to adjacent transit and backbone areas. External routes from outside the AS can be advertised within the NSSA but are not distributed into other areas.
188 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
Transit Area—an area that allows area summary information to be exchanged between routing devices. The backbone (area 0), any area that contains a virtual link to connect two areas, and any area that is not a stub area or an NSSA are considered transit areas.
Backbone
Area 0
(Also a Transit Area)
ABR ABR
ABR
Internal LSA
Routes
Not-So-Stubby Area
(NSSA)
External LSA
Routes
ASBR
Stub Area
No External Routes from Backbone
ABR = Area Border Router
ASBR = Autonomous System
Boundary Router
Non-OSPF Area
RIP/BGP AS
Figure 12-1 OSPF Area Types
Transit Area
Virtual
Link
ABR
Stub Area, NSSA, or Transit Area
Connected to Backbone via Virtual Link
42C4911, January 2007 Chapter 12: OSPF 189
Alteon OS Application Guide
Types of OSPF Routing Devices
As shown in
, OSPF uses the following types of routing devices:
Internal Router (IR)—a router that has all of its interfaces within the same area. IRs maintain LSDBs identical to those of other routing devices within the local area.
Area Border Router (ABR)—a router that has interfaces in multiple areas. ABRs maintain one LSDB for each connected area and disseminate routing information between areas.
Autonomous System Boundary Router (ASBR)—a router that acts as a gateway between the OSPF domain and non-OSPF domains, such as RIP, BGP, and static routes.
BGP
OSPF Autonomous System
Backbone
Area 0
Inter-Area Routes
(Summary Routes)
ABR
Area 3
External
Routes
RIP
ASBR
ASBR
Area 1
ABR
ABR
Internal
Router
Area 2
Figure 12-2 OSPF Domain and an Autonomous System
190 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
Neighbors and Adjacencies
In areas with two or more routing devices, neighbors and adjacencies are formed.
Neighbors are routing devices that maintain information about each others’ health. To establish neighbor relationships, routing devices periodically send hello packets on each of their interfaces. All routing devices that share a common network segment, appear in the same area, and have the same health parameters (hello and dead intervals) and authentication parameters respond to each other’s hello packets and become neighbors. Neighbors continue to send periodic hello packets to advertise their health to neighbors. In turn, they listen to hello packets to determine the health of their neighbors and to establish contact with new neighbors.
The hello process is used for electing one of the neighbors as the area’s Designated Router
(DR) and one as the area’s Backup Designated Router (BDR). The DR is adjacent to all other neighbors and acts as the central contact for database exchanges. Each neighbor sends its database information to the DR, which relays the information to the other neighbors.
The BDR is adjacent to all other neighbors (including the DR). Each neighbor sends its database information to the BDR just as with the DR, but the BDR merely stores this data and does not distribute it. If the DR fails, the BDR will take over the task of distributing database information to the other neighbors.
The Link-State Database
OSPF is a link-state routing protocol. A link represents an interface (or routable path) from the routing device. By establishing an adjacency with the DR, each routing device in an OSPF area maintains an identical Link-State Database (LSDB) describing the network topology for its area.
Each routing device transmits a Link-State Advertisement (LSA) on each of its interfaces.
LSAs are entered into the LSDB of each routing device. OSPF uses flooding to distribute
LSAs between routing devices.
When LSAs result in changes to the routing device’s LSDB, the routing device forwards the changes to the adjacent neighbors (the DR and BDR) for distribution to the other neighbors.
OSPF routing updates occur only when changes occur, instead of periodically. For each new route, if an adjacency is interested in that route (for example, if configured to receive static routes and the new route is indeed static), an update message containing the new route is sent to the adjacency. For each route removed from the route table, if the route has already been sent to an adjacency, an update message containing the route to withdraw is sent.
42C4911, January 2007 Chapter 12: OSPF 191
Alteon OS Application Guide
The Shortest Path First Tree
The routing devices use a link-state algorithm (Dijkstra’s algorithm) to calculate the shortest path to all known destinations, based on the cumulative cost required to reach the destination.
The cost of an individual interface in OSPF is an indication of the overhead required to send packets across it. The cost is inversely proportional to the bandwidth of the interface. A lower cost indicates a higher bandwidth.
Internal Versus External Routing
To ensure effective processing of network traffic, every routing device on your network needs to know how to send a packet (directly or indirectly) to any other location/destination in your network. This is referred to as internal routing and can be done with static routes or using active internal routing protocols, such as OSPF, RIP, or RIPv2.
It is also useful to tell routers outside your network (upstream providers or peers) about the routes you have access to in your network. Sharing of routing information between autonomous systems is known as external routing.
Typically, an AS will have one or more border routers (peer routers that exchange routes with other OSPF networks) as well as an internal routing system enabling every router in that AS to reach every other router and destination within that AS.
When a routing device advertises routes to boundary routers on other autonomous systems, it is effectively committing to carry data to the IP space represented in the route being advertised.
For example, if the routing device advertises 192.204.4.0/24, it is declaring that if another router sends data destined for any address in the 192.204.4.0/24 range, it will carry that data to its destination.
192 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
OSPF Implementation in Alteon OS
Alteon OS supports a single instance of OSPF and up to 4 K routes on the network. The following sections describe OSPF implementation in Alteon OS:
“Configurable Parameters” on page 193
“Electing the Designated Router and Backup” on page 196
“Summarizing Routes” on page 196
Configurable Parameters
In Alteon OS, OSPF parameters can be configured through the Command Line Interfaces
(CLI/ISCLI), Browser-Based Interface (BBI), or through SNMP. For more information, see
Chapter 1, “Accessing the Switch .”
The CLI supports the following parameters: interface output cost, interface priority, dead and hello intervals, retransmission interval, and interface transmit delay.
In addition to the above parameters, you can also specify the following:
Shortest Path First (SPF) interval—Time interval between successive calculations of the shortest path tree using the Dijkstra’s algorithm.
Stub area metric—A stub area can be configured to send a numeric metric value such that all routes received via that stub area carry the configured metric to potentially influence routing decisions.
Default routes—Default routes with weight metrics can be manually injected into transit areas. This helps establish a preferred route when multiple routing devices exist between two areas. It also helps route traffic to external networks.
42C4911, January 2007 Chapter 12: OSPF 193
Alteon OS Application Guide
Defining Areas
If you are configuring multiple areas in your OSPF domain, one of the areas must be designated as area 0, known as the backbone. The backbone is the central OSPF area and is usually physically connected to all other areas. The areas inject routing information into the backbone which, in turn, disseminates the information into other areas.
Since the backbone connects the areas in your network, it must be a contiguous area. If the backbone is partitioned (possibly as a result of joining separate OSPF networks), parts of the
AS will be unreachable, and you will need to configure virtual links to reconnect the partitioned areas (see
“Virtual Links” on page 198 ).
Up to three OSPF areas can be connected to the GbE Switch Module with Alteon OS software.
To configure an area, the OSPF number must be defined and then attached to a network interface on the switch. The full process is explained in the following sections.
An OSPF area is defined by assigning two pieces of information—an area index and an area
ID. The command to define an OSPF area is as follows:
>> # /cfg/l3/ospf/aindex <area index>/areaid <n.n.n.n>
N OTE – The aindex option above is an arbitrary index used only on the switch and does not represent the actual OSPF area number. The actual OSPF area number is defined in the areaid portion of the command as explained in the following sections.
Assigning the Area Index
The aindex <area index> option is actually just an arbitrary index (0-2) used only by the
GbE Switch Module. This index does not necessarily represent the OSPF area number, though for configuration simplicity, it should where possible.
For example, both of the following sets of commands define OSPF area 0 (the backbone) and area 1 because that information is held in the area ID portion of the command. However, the first set of commands is easier to maintain because the arbitrary area indexes agree with the area IDs:
Area index and area ID agree
/cfg/l3/ospf/aindex 0/areaid 0.0.0.0
/cfg/l3/ospf/aindex 1/areaid 0.0.0.1
Area index set to an arbitrary value
(Use index 0 to set area 0 in ID octet format)
(Use index 1 to set area 1 in ID octet format)
/cfg/l3/ospf/aindex 1/areaid 0.0.0.0
/cfg/l3/ospf/aindex 2/areaid 0.0.0.1
(Use index 1 to set area 0 in ID octet format)
(Use index 2 to set area 1 in ID octet format)
194 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
Using the Area ID to Assign the OSPF Area Number
The OSPF area number is defined in the areaid <IP address> option. The octet format is used in order to be compatible with two different systems of notation used by other OSPF network vendors. There are two valid ways to designate an area ID:
Placing the area number in the last octet (0.0.0.n)
Most common OSPF vendors express the area ID number as a single number. For example, the Cisco IOS-based router command “network 1.1.1.0 0.0.0.255 area 1” defines the area number simply as “area 1.” On the GbE Switch Module, using the last octet in the area ID, “area 1” is equivalent to “areaid 0.0.0.1”.
Multi-octet (IP address)
Some OSPF vendors express the area ID number in multi-octet format. For example,
“area 2.2.2.2” represents OSPF area 2 and can be specified directly on the GbE
Switch Module as “areaid 2.2.2.2”.
N OTE – Although both types of area ID formats are supported, be sure that the area IDs are in the same format throughout an area.
Attaching an Area to a Network
Once an OSPF area has been defined, it must be associated with a network. To attach the area to a network, you must assign the OSPF area index to an IP interface that participates in the area. The format for the command is as follows:
>> # /cfg/l3/ospf/if <interface number>/aindex <area index>
For example, the following commands could be used to configure IP interface 14 for a presence on the 10.10.10.1/24 network, to define OSPF area 1, and to attach the area to the network:
>> # /cfg/l3/if 14
>> IP Interface 14# addr 10.10.10.1
(Select menu for IP interface 14)
(Define IP address on backbone
network)
>> IP Interface 14# mask 255.255.255.0
>> IP Interface 14# ena
>> IP Interface 14# ../ospf/aindex 1
(Define IP mask on backbone)
(Enable IP interface 14)
( Select menu for area index 1)
>> OSPF Area (index) 1 # areaid 0.0.0.1
>> OSPF Area (index) 1 # ena
>> OSPF Area (index) 1 # ../if 14
>> OSPF Interface 14# aindex 1
>> OSPF Interface 14# enable
(Define area ID as OSPF area 1)
(Enable area index 1)
(Select OSPF menu for interface 14)
(Attach area to network on interface
14)
(Enable interface 14 for area index 1)
42C4911, January 2007 Chapter 12: OSPF 195
Alteon OS Application Guide
Interface Cost
The OSPF link-state algorithm (Dijkstra’s algorithm) places each routing device at the root of a tree and determines the cumulative cost required to reach each destination. Usually, the cost is inversely proportional to the bandwidth of the interface. Low cost indicates high bandwidth.
You can manually enter the cost for the output route with the following command:
>> # /cfg/l3/ospf/if < OSPF interface number > /cost < cost value (1-65535) >
Electing the Designated Router and Backup
In any area with more than two routing devices, a Designated Router (DR) is elected as the central contact for database exchanges among neighbors, and a Backup Designated Router
(BDR) is elected in case the DR fails.
DR and BDR elections are made through the hello process. The election can be influenced by assigning a priority value to the OSPF interfaces on the GbE Switch Module. The command is as follows:
>> # /cfg/l3/ospf/if <OSPF interface number>/prio <priority value (0-255)>
A priority value of 255 is the highest, and 1 is the lowest. A priority value of 0 specifies that the interface cannot be used as a DR or BDR. In case of a tie, the routing device with the lowest router ID wins.
Summarizing Routes
Route summarization condenses routing information. Without summarization, each routing device in an OSPF network would retain a route to every subnet in the network. With summarization, routing devices can reduce some sets of routes to a single advertisement, reducing both the load on the routing device and the perceived complexity of the network. The importance of route summarization increases with network size.
Summary routes can be defined for up to 16 IP address ranges using the following command:
>> # /cfg/l3/ospf/range <range number>/addr <IP address>/mask
<mask> where <range number> is a number 1 to 16, <IP address> is the base IP address for the range, and <mask> is the IP address mask for the range. For a detailed configuration example, see
“Example 3: Summarizing Routes” on page 211
.
196 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
Default Routes
When an OSPF routing device encounters traffic for a destination address it does not recognize, it forwards that traffic along the default route. Typically, the default route leads upstream toward the backbone until it reaches the intended area or an external router.
Each GbE Switch Module acting as an ABR automatically inserts a default route into each attached area. In simple OSPF stub areas or NSSAs with only one ABR leading upstream (see
Area 1 in Figure 12-3 ), any traffic for IP address destinations outside the area is forwarded to
the switch’s IP interface, and then into the connected transit area (usually the backbone). Since this is automatic, no further configuration is required for such areas.
BladeCenter
BladeCenter
Figure 12-3 Injecting Default Routes
If the switch is in a transit area and has a configured default gateway, it can inject a default route into rest of the OSPF domain. Use the following command to configure the switch to inject OSPF default routes:
>> # /cfg/l3/ospf/default <metric value> <metric type (1 or 2)>
In the command above, <metric value> sets the priority for choosing this switch for default route. The value none sets no default and 1 sets the highest priority for default route. Metric type determines the method for influencing routing decisions for external routes.
When the switch is configured to inject a default route, an AS-external LSA with link state
ID 0.0.0.0 is propagated throughout the OSPF routing domain. This LSA is sent with the configured metric value and metric type.
42C4911, January 2007 Chapter 12: OSPF 197
Alteon OS Application Guide
The OSPF default route configuration can be removed with the command:
>> # /cfg/l3/ospf/default none
Virtual Links
Usually, all areas in an OSPF AS are physically connected to the backbone. In some cases where this is not possible, you can use a virtual link. Virtual links are created to connect one area to the backbone through another non-backbone area (see
).
The area which contains a virtual link must be a transit area and have full routing information.
Virtual links cannot be configured inside a stub area or NSSA. The area type must be defined as transit using the following command:
>> # /cfg/l3/ospf/aindex <area index>/type transit
The virtual link must be configured on the routing devices at each endpoint of the virtual link, though they may traverse multiple routing devices. To configure a GbE Switch Module as one endpoint of a virtual link, use the following command:
>> # /cfg/l3/ospf/virt <link number>/aindex <area index>/nbr <router
ID> where <link number> is a value between 1 and 3, <area index> is the OSPF area index of the transit area, and <router ID> is the IP address of the virtual neighbor (nbr), the routing device at the target endpoint. Another router ID is needed when configuring a virtual link in the other
direction. To provide the GbE Switch Module with a router ID, see the following section
.
For a detailed configuration example on Virtual Links, see
“Example 2: Virtual Links” on page
198 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
Router ID
Routing devices in OSPF areas are identified by a router ID. The router ID is expressed in IP address format. The IP address of the router ID is not required to be included in any IP interface range or in any OSPF area.
The router ID can be configured in one of the following two ways:
Dynamically—OSPF protocol configures the lowest IP interface IP address as the router
ID. This is the default.
Statically—Use the following command to manually configure the router ID:
>> # /cfg/l3/rtrid <IP address>
To modify the router ID from static to dynamic, set the router ID to 0.0.0.0, save the configuration, and reboot the GbE Switch Module. To view the router ID, enter:
>> # /info/l3/ospf/gen
Authentication
OSPF protocol exchanges can be authenticated so that only trusted routing devices can participate. This ensures less processing on routing devices that are not listening to OSPF packets.
OSPF allows packet authentication and uses IP multicast when sending and receiving packets.
Routers participate in routing domains based on predefined passwords. Alteon OS supports simple password (type 1 plain text passwords) and MD5 cryptographic authentication. This type of authentication allows a password to be configured per area.
42C4911, January 2007 Chapter 12: OSPF 199
Alteon OS Application Guide
shows authentication configured for area 0 with the password test. Simple authentication is also configured for the virtual link between area 2 and area 0. Area 1 is not configured for OSPF authentication.
BladeCenter
BladeCenter
Figure 12-4 OSPF Authentication
To configure simple plain text OSPF passwords on the switches shown in
following commands:
1.
Enable OSPF authentication for Area 0 on switches 1, 2, and 3.
>> # /cfg/l3/ospf/aindex 0/auth password
(Turn on OSPF password authenti cation)
2.
Configure a simple text password up to eight characters for each OSPF IP interface in
Area 0 on switches 1, 2, and 3.
>> # /cfg/l3/ospf/if 1
>> OSPF Interface 1 # key test
>> OSPF Interface 1 # ../if 2
>> OSPF Interface 2 # key test
>> OSPF Interface 1 # ../if 3
>> OSPF Interface 3 # key test
200 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
3.
Enable OSPF authentication for Area 2 on switch 4.
>> # /cfg/l3/ospf/aindex 2/auth password
(Turn on OSPF password authenti-
c ation)
4.
Configure a simple text password up to eight characters for the virtual link between Area
2 and Area 0 on switches 2 and 4.
>> # /cfg/l3/ospf/virt 1/key alteon
Use the following commands to configure MD5 authentication on the switches shown in Figure 12-4
:
1.
Enable OSPF MD5 authentication for Area 0 on switches 1, 2, and 3.
>> # /cfg/l3/ospf/aindex 0/auth md5 (Turn on MD5 authentication)
2.
Configure MD5 key ID for Area 0 on switches 1, 2, and 3.
>> # /cfg/l3/ospf/md5key 1/key test
3.
Assign MD5 key ID to OSPF interfaces on switches 1, 2, and 3.
>> # /cfg/l3/ospf/if 1
>> OSPF Interface 1 # mdkey 1
>> OSPF Interface 1 # ../if 2
>> OSPF Interface 2 # mdkey 1
>> OSPF Interface 1 # ../if 3
>> OSPF Interface 3 # mdkey 1
4.
Enable OSPF MD5 authentication for Area 2 on switch 4.
>> # /cfg/l3/ospf/aindex 2/auth md5
5.
Configure MD5 key for the virtual link between Area 2 and Area 0 on switches 2 and 4.
>> # /cfg/l3/ospf/md5key 2/key alteon
42C4911, January 2007 Chapter 12: OSPF 201
Alteon OS Application Guide
6.
Assign MD5 key ID to OSPF virtual link on switches 2 and 4.
>> # /cfg/l3/ospf/virt 1/mdkey 2
Host Routes for Load Balancing
Alteon OS implementation of OSPF includes host routes. Host routes are used for advertising network device IP addresses to external networks, accomplishing the following goals:
ABR Load Sharing
As a form of load balancing, host routes can be used for dividing OSPF traffic among multiple ABRs. To accomplish this, each switch provides identical services but advertises a host route for a different IP address to the external network. If each IP address serves a different and equal portion of the external world, incoming traffic from the upstream router should be split evenly among ABRs.
ABR Failover
Complementing ABR load sharing, identical host routes can be configured on each ABR.
These host routes can be given different costs so that a different ABR is selected as the preferred route for each server and the others are available as backups for failover purposes.
Equal Cost Multipath (ECMP)
With equal cost multipath, a router potentially has several available next hops towards any given destination. ECMP allows separate routes to be calculated for each IP Type of Service. All paths of equal cost to a given destination are calculated, and the next hops for all equal-cost paths are inserted into the routing table.
If redundant routes via multiple routing processes (such as OSPF, RIP, BGP, or static routes) exist on your network, the switch defaults to the OSPF-derived route.
202 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
OSPF Features Not Supported in This Release
The following OSPF features are not supported in this release:
Summarizing external routes
Filtering OSPF routes
Using OSPF to forward multicast routes
Configuring OSPF on non-broadcast multi-access networks (such as frame relay, X.25, and ATM)
42C4911, January 2007 Chapter 12: OSPF 203
Alteon OS Application Guide
OSPF Configuration Examples
A summary of the basic steps for configuring OSPF on the GbE Switch Module is listed here.
Detailed instructions for each of the steps is covered in the following sections:
1.
Configure IP interfaces.
One IP interface is required for each desired network (range of IP addresses) being assigned to an OSPF area on the switch.
2.
(Optional) Configure the router ID.
The router ID is required only when configuring virtual links on the switch.
3.
Enable OSPF on the switch.
4.
Define the OSPF areas.
5.
Configure OSPF interface parameters.
IP interfaces are used for attaching networks to the various areas.
6.
(Optional) Configure route summarization between OSPF areas.
7.
(Optional) Configure virtual links.
8.
(Optional) Configure host routes.
204 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
Example 1: Simple OSPF Domain
In this example, two OSPF areas are defined—one area is the backbone and the other is a stub area. A stub area does not allow advertisements of external routes, thus reducing the size of the database. Instead, a default summary route of IP address 0.0.0.0 is automatically inserted into the stub area. Any traffic for IP address destinations outside the stub area will be forwarded to the stub area’s IP interface, and then into the backbone.
Network
10.10.7.0/24
BladeCenter Network
10.10.12.0/24
Figure 12-5 A Simple OSPF Domain
Follow this procedure to configure OSPF support as shown in
:
1.
Configure IP interfaces on each network that will be attached to OSPF areas.
In this example, two IP interfaces are needed: one for the backbone network on 10.10.7.0/24 and one for the stub area network on 10.10.12.0/24.
>> # /cfg/l3/if 1
>> IP Interface 1 # addr 10.10.7.1
>> IP Interface 1 # mask 255.255.255.0
>> IP Interface 1 # enable
>> IP Interface 1 # ../if 2
>> IP Interface 2 # addr 10.10.12.1
>> IP Interface 2 # mask 255.255.255.0
>> IP Interface 2 # enable
(Select menu for IP interface 1)
(Set IP address on backbone network)
(Set IP mask on backbone network)
(Enable IP interface 1)
(Select menu for IP interface 2)
(Set IP address on stub area network)
(Set IP mask on stub area network)
(Enable IP interface 2)
2.
Enable OSPF.
>> IP Interface 2 # /cfg/l3/ospf/on (Enable OSPF on the switch)
42C4911, January 2007 Chapter 12: OSPF 205
Alteon OS Application Guide
3.
Define the backbone.
The backbone is always configured as a transit area using areaid 0.0.0.0.
>> Open Shortest Path First # aindex 0
>> OSPF Area (index) 0 # areaid 0.0.0.0
>> OSPF Area (index) 0 # type transit
>> OSPF Area (index) 0 # enable
(Select menu for area index 0)
(Set the ID for backbone area 0)
(Define backbone as transit type)
(Enable the area)
4.
Define the stub area.
>> OSPF Area (index) 0 # ../aindex 1
>> OSPF Area (index) 1 # areaid 0.0.0.1
>> OSPF Area (index) 1 # type stub
>> OSPF Area (index) 1 # enable
(Select menu for area index 1)
(Set the area ID for OSPF area 1)
(Define area as stub type)
(Enable the area)
5.
Attach the network interface to the backbone.
>> OSPF Area 1 # ../if 1
>> OSPF Interface 1 # aindex 0
>> OSPF Interface 1 # enable
(Select OSPF menu for IP interface 1)
(Attach network to backbone index)
(Enable the backbone interface)
6.
Attach the network interface to the stub area.
>> OSPF Interface 1 # ../if 2
>> OSPF Interface 2 # aindex 1
>> OSPF Interface 2 # enable
7.
Apply and save the configuration changes.
>> OSPF Interface 2 # apply
>> OSPF Interface 2 # save
(Select OSPF menu for IP interface 2)
(Attach network to stub area index)
(Enable the stub area interface)
(Global command to apply all changes)
(Global command to save all changes)
206 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
Example 2: Virtual Links
In the example shown in Figure 12-6
, area 2 is not physically connected to the backbone as is usually required. Instead, area 2 will be connected to the backbone via a virtual link through area 1. The virtual link must be configured at each endpoint.
Figure 12-6 Configuring a Virtual Link
Configuring OSPF for a Virtual Link on Switch #1
1.
Configure IP interfaces on each network that will be attached to the switch.
In this example, two IP interfaces are needed on Switch #1: one for the backbone network on
10.10.7.0/24 and one for the transit area network on 10.10.12.0/24.
>> # /cfg/l3/if 1
>> IP Interface 1 # addr 10.10.7.1
(Select menu for IP interface 1)
(Set IP address on backbone network)
>> IP Interface 1 # mask 255.255.255.0 (Set IP mask on backbone network)
>> IP Interface 1 # enable
>> IP Interface 1 # ../if 2
(Enable IP interface 1)
(Select menu for IP interface 2)
>> IP Interface 2 # addr 10.10.12.1 (Set IP address on transit area network)
>> IP Interface 2 # mask 255.255.255.0 (Set IP mask on transit area network)
>> IP Interface 2 # enable (Enable interface 2)
2.
Configure the router ID.
A router ID is required when configuring virtual links. Later, when configuring the other end of the virtual link on Switch 2, the router ID specified here will be used as the target virtual neighbor (nbr) address.
>> IP Interface 2 # /cfg/l3/rtrid 10.10.10.1 (Set static router ID on switch 1)
3.
Enable OSPF.
>> IP # /cfg/l3/ospf/on (Enable OSPF on switch 1)
42C4911, January 2007 Chapter 12: OSPF 207
Alteon OS Application Guide
4.
Define the backbone.
>> Open Shortest Path First # aindex 0
>> OSPF Area (index) 0 # areaid 0.0.0.0
>> OSPF Area (index) 0 # type transit
>> OSPF Area (index) 0 # enable
(Select menu for area index 0)
(Set the area ID for backbone area 0)
(Define backbone as transit type)
(Enable the area)
5.
Define the transit area.
The area that contains the virtual link must be configured as a transit area.
>> OSPF Area (index) 0 # ../aindex 1
>> OSPF Area (index) 1 # areaid 0.0.0.1
>> OSPF Area (index) 1 # type transit
>> OSPF Area (index) 1 # enable
(Select menu for area index 1)
(Set the area ID for OSPF area 1)
(Define area as transit type)
(Enable the area)
6.
Attach the network interface to the backbone.
>> OSPF Area (index) 1 # ../if 1
>> OSPF Interface 1 # aindex 0
>> OSPF Interface 1 # enable
(Select OSPF menu for IP interface 1)
(Attach network to backbone index)
(Enable the backbone interface)
7.
Attach the network interface to the transit area.
>> OSPF Interface 1 # ../if 2
>> OSPF Interface 2 # aindex 1
>> OSPF Interface 2 # enable
(Select OSPF menu for IP interface 2)
(Attach network to transit area index)
(Enable the transit area interface)
8.
Configure the virtual link.
The nbr router ID configured in this step must be the same as the router ID that will be config-
ured for Switch #2 in Step 2 on page 209 .
>> OSPF Interface 2 # ../virt 1
>> OSPF Virtual Link 1 # aindex 1
>> OSPF Virtual Link 1 # nbr 10.10.14.1
>> OSPF Virtual Link 1 # enable
(Specify a virtual link number)
(Specify the transit area for the virtual link)
(Specify the router ID of the recipient)
(Enable the virtual link)
9.
Apply and save the configuration changes.
>> OSPF Interface 2 # apply
>> OSPF Interface 2 # save
(Global command to apply all changes)
(Global command to save all changes)
208 Chapter 12: OSPF 42C4911, January 2007
42C4911, January 2007
Alteon OS Application Guide
Configuring OSPF for a Virtual Link on Switch #2
1.
Configure IP interfaces on each network that will be attached to OSPF areas.
Two IP interfaces are needed on Switch #2: one for the transit area network on 10.10.12.0/24 and one for the stub area network on 10.10.24.0/24.
>> # /cfg/l3/if 1
>> IP Interface 1 # addr 10.10.12.2
>> IP Interface 1 # mask 255.255.255.0
>> IP Interface 1 # enable
>> IP Interface 1 # ../if 2
>> IP Interface 2 # addr 10.10.24.1
>> IP Interface 2 # mask 255.255.255.0
>> IP Interface 2 # enable
(Select menu for IP interface 1)
(Set IP address on transit area net-
work)
(Set IP mask on transit area network)
(Enable IP interface 1)
(Select menu for IP interface 2)
(Set IP address on stub area network)
(Set IP mask on stub area network)
(Enable IP interface 2)
2.
Configure the router ID.
A router ID is required when configuring virtual links. This router ID should be the same one specified as the target virtual neighbor (nbr) on switch 1 in
.
>> IP Interface 2 # /cfg/l3/rtrid 10.10.14.1 (Set static router ID on switch 2)
3.
Enable OSPF.
>> IP# /cfg/l3/ospf/on (Enable OSPF on switch 2)
4.
Define the backbone.
This version of Alteon OS requires that a backbone index be configured on the non-backbone end of the virtual link as follows:
>> Open Shortest Path First # aindex 0
>> OSPF Area (index) 0 # areaid 0.0.0.0
>> OSPF Area (index) 0 # enable
(Select the menu for area index 0)
(Set the area ID for OSPF area 0)
(Enable the area)
5.
Define the transit area.
>> OSPF Area (index) 0 # ../aindex 1
>> OSPF Area (index) 1 # areaid 0.0.0.1
>> OSPF Area (index) 1 # type transit
>> OSPF Area (index) 1 # enable
(Select menu for area index 1)
(Set the area ID for OSPF area 1)
(Define area as transit type)
(Enable the area)
Chapter 12: OSPF 209
Alteon OS Application Guide
6.
Define the stub area.
>> OSPF Area (index) 1 # ../aindex 2
>> OSPF Area (index) 2 # areaid 0.0.0.2
>> OSPF Area (index) 2 # type stub
>> OSPF Area (index) 2 # enable
(Select the menu for area index 2)
(Set the area ID for OSPF area 2)
(Define area as stub type)
(Enable the area)
7.
Attach the network interface to the backbone.
>> OSPF Area (index) 2 # ../if 1
>> OSPF Interface 1 # aindex 1
>> OSPF Interface 1 # enable
(Select OSPF menu for IP interface 1)
(Attach network to transit area index)
(Enable the transit area interface)
8.
Attach the network interface to the transit area.
>> OSPF Interface 1 # ../if 2
>> OSPF Interface 2 # aindex 2
>> OSPF Interface 2 # enable
(Select OSPF menu for IP interface 2)
(Attach network to stub area index)
(Enable the stub area interface)
9.
Configure the virtual link.
The nbr router ID configured in this step must be the same as the router ID that was configured for switch #1 in
.
>> OSPF Interface 2 # ../virt 1
>> OSPF Virtual Link 1 # aindex 1
>> OSPF Virtual Link 1 # nbr 10.10.10.1
>> OSPF Virtual Link 1 # enable
(Specify a virtual link number)
(Specify the transit area for the virtual link)
(Specify the router ID of the recipient)
(Enable the virtual link)
10.
Apply and save the configuration changes.
>> OSPF Interface 2 # apply
>> OSPF Interface 2 # save
(Global command to apply all changes)
(Global command to save all changes)
Other Virtual Link Options
You can use redundant paths by configuring multiple virtual links.
Only the endpoints of the virtual link are configured. The virtual link path may traverse multiple routers in an area as long as there is a routable path between the endpoints.
210 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
Example 3: Summarizing Routes
By default, ABRs advertise all the network addresses from one area into another area. Route summarization can be used for consolidating advertised addresses and reducing the perceived complexity of the network.
If the network IP addresses in an area are assigned to a contiguous subnet range, you can configure the ABR to advertise a single summary route that includes all the individual IP addresses within the area.
The following example shows one summary route from area 1 (stub area) injected into area 0
(the backbone). The summary route consists of all IP addresses from 36.128.192.0 through
36.128.254.255 except for the routes in the range 36.128.200.0 through 36.128.200.255.
Figure 12-7 Summarizing Routes
N
OTE
– You can specify a range of addresses to prevent advertising by using the hide option. In this example, routes in the range 36.128.200.0 through 36.128.200.255 are kept private.
42C4911, January 2007 Chapter 12: OSPF 211
Alteon OS Application Guide
Follow this procedure to configure OSPF support as shown in
:
1.
Configure IP interfaces for each network which will be attached to OSPF areas.
>> # /cfg/l3/if 1
>> IP Interface 1 # addr 10.10.7.1
>> IP Interface 1 # mask 255.255.255.0
>> IP Interface 1 # ena
>> IP Interface 1 # ../if 2
>> IP Interface 2 # addr 36.128.192.1
>> IP Interface 2 # mask 255.255.192.0
>> IP Interface 2 # ena
(Select menu for IP interface 1)
(Set IP address on backbone network)
(Set IP mask on backbone network)
(Enable IP interface 1)
(Select menu for IP interface 2)
(Set IP address on stub area network)
(Set IP mask on stub area network)
(Enable IP interface 2)
2.
Enable OSPF.
>> IP Interface 2 # /cfg/l3/ospf/on (Enable OSPF on the switch)
3.
Define the backbone.
>> Open Shortest Path First # aindex 0 (Select menu for area index 0)
>> OSPF Area (index) 0 # areaid 0.0.0.0 (Set the ID for backbone area 0)
>> OSPF Area (index) 0 # type transit
>> OSPF Area (index) 0 # enable
(Define backbone as transit type)
(Enable the area)
4.
Define the stub area.
>> OSPF Area (index) 0 # ../aindex 1 (Select menu for area index 1)
>> OSPF Area (index) 1 # areaid 0.0.0.1 (Set the area ID for OSPF area 1)
>> OSPF Area (index) 1 # type stub
>> OSPF Area (index) 1 # enable
(Define area as stub type)
(Enable the area)
5.
Attach the network interface to the backbone.
>> OSPF Area (index) 1 # ../if 1
>> OSPF Interface 1 # aindex 0
>> OSPF Interface 1 # enable
6.
Attach the network interface to the stub area.
>> OSPF Interface 1 # ../if 2
>> OSPF Interface 2 # aindex 1
>> OSPF Interface 2 # enable
(Select OSPF menu for IP interface 1)
(Attach network to backbone index)
(Enable the backbone interface)
(Select OSPF menu for IP interface 2)
(Attach network to stub area index)
(Enable the stub area interface)
212 Chapter 12: OSPF 42C4911, January 2007
Alteon OS Application Guide
7.
Configure route summarization by specifying the starting address and mask of the range of addresses to be summarized.
>> OSPF Interface 2 # ../range 1
>> OSPF Summary Range 1 # addr 36.128.192.0
(Select menu for summary range)
(Set base IP address of summary range)
>> OSPF Summary Range 1 # mask 255.255.192.0 (Set mask address for summary range)
>> OSPF Summary Range 1 # aindex 0
>> OSPF Summary Range 1 # enable
(Inject summary route into backbone)
(Enable summary range)
8.
Use the hide command to prevent a range of addresses from advertising to the backbone.
>> OSPF Interface 2 # ../range 2
>> OSPF Summary Range 2 # addr 36.128.200.0
(Select menu for summary range)
(Set base IP address)
>> OSPF Summary Range 2 # mask 255.255.255.0 (Set mask address)
>> OSPF Summary Range 2 # hide enable (Hide the range of addresses)
9.
Apply and save the configuration changes.
>> OSPF Summary Range 2 # apply
>> OSPF Summary Range 2 # save
(Global command to apply all changes)
(Global command to save all changes)
Verifying OSPF Configuration
Use the following commands to verify the OSPF configuration on your switch:
/info/l3/ospf/general
/info/l3/ospf/nbr
/info/l3/ospf/dbase/dbsum
/info/l3/ospf/route
/stats/l3/route
Refer to the Alteon OS Command Reference for information on the above commands.
42C4911, January 2007 Chapter 12: OSPF 213
Alteon OS Application Guide
214 Chapter 12: OSPF 42C4911, January 2007
Part 3: High Availability
Fundamentals
Internet traffic consists of myriad services and applications which use the Internet Protocol
(IP) for data delivery. However, IP is not optimized for all the various applications. High
Availability goes beyond IP and makes intelligent switching decisions to provide redundant network configurations.
High Availability
42C4911, January 2007
Alteon OS Application Guide
216 42C4911, January 2007
C HAPTER 13
High Availability
GbE Switch Modules support high-availability network topologies through an enhanced implementation of the Virtual Router Redundancy Protocol (VRRP).
The following topics are discussed in this chapter:
“Layer 2 Failover” on page 218
. This section discusses trunk failover without using
VRRP.
. This section discusses VRRP operation and Alteon OS redundancy configurations.
“Failover Methods” on page 227 . This section describes the three modes of high availabil-
ity.
“Alteon OS extensions to VRRP” on page 230
. This section describes VRRP enhancements implemented in Alteon OS.
“Virtual Router Deployment Considerations” on page 231 . This section describes issues to
consider when deploying virtual routers.
“High Availability Configurations” on page 233
. This section discusses the more useful and easily deployed redundant configurations.
“Active-Active Configuration” on page 233
“Hot-Standby Configuration” on page 238
42C4911, January 2007 217
Alteon OS Application Guide
Layer 2 Failover
The primary application for Layer 2 Failover is to support Network Adapter Teaming.
With Network Adapter Teaming, the NICs on each server all share the same IP address, and are configured into a team. One NIC is the primary link, and the other is a standby link.
For more details, refer to the NetXen 10 Gb Ethernet Adapter documentation.
N OTE – Only two links per server blade can be used for Layer 2 Trunk Failover
(one primary and one backup). Network Adapter Teaming allows only one backup NIC for each server blade.
Layer 2 Failover can be enabled on any trunk group in the GbE Switch Module, including
LACP trunks. Trunks can be added to failover trigger groups such that if some (or all) of the links fail in a trigger, the switch disables all internal ports in the switch (unless VLAN Monitor is turned on). When the internal ports are disabled, it causes the NIC team on the affected server blades to failover from the primary to the backup NIC. This process is called a failover event.
When the appropriate number of links in a trigger group return to service, the switch enables the internal ports. This causes the NIC team on the affected server blades to fail back to the primary switch (unless Auto-Fallback is disabled on the NIC team). The backup switch processes traffic until the primary switch’s internal links come up, which takes up to five seconds.
VLAN Monitor
The VLAN Monitor allows L2 Failover to discern different VLANs. With VLAN Monitor turned on:
If enough links in a trigger go down (see
“Setting the Failover Limit” on page 219
), the switch disables all internal ports that reside in the same VLAN membership as the trunk(s) in the trigger.
When enough links in the trigger return to service, the switch enables the internal ports that reside in the same VLAN membership as the trunk(s) in the trigger.
If you turn off the VLAN Monitor (/cfg/failovr/vlan/off), only one failover trigger is allowed. When a link failure occurs on the trigger, the switch disables all internal serverblade ports.
218 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
Setting the Failover Limit
The failover limit lets you specify the minimum number of operational links required within each trigger before the trigger initiates a failover event. For example, if the limit is two
(/cfg/l2/failovr/trigger x/limit 2), a failover event occurs when the number of operational links in the trigger is two or fewer. When you set the limit to zero, the switch triggers a failover event only when no links in the trigger are operational.
L2 Failover with Other Features
L2 Failover works together with Link Aggregation Control Protocol (LACP) and with
Spanning Tree Protocol (STP), as described below.
LACP
Link Aggregation Control Protocol allows the switch to form dynamic trunks.
You can use the admin key to add LACP trunks to a failover trigger. When you add an admin
key to a trigger (/cfg/failovr/trigger x/amon/addkey), any LACP trunk with that admin key becomes a member of the trigger.
Spanning Tree Protocol
If Spanning Tree Protocol (STP) is enabled on the ports in a failover trigger, the switch monitors the port STP state rather than the link state. A port failure results when STP is not in a Forwarding state (that is, Listening, Learning, Blocking, or No Link). The switch automatically disables the appropriate internal ports, based on the VLAN monitor.
When the switch determines that ports in the trigger are in STP Forwarding state, then it automatically enables the appropriate internal ports, based on the VLAN monitor. The switch fails
back to normal operation.
42C4911, January 2007 Chapter 13: High Availability 219
Alteon OS Application Guide
Configuration Guidelines
This section provides important information about configuring L2 Failover:
A failover trigger can monitor multiple static trunks or a single LACP key, but not both.
With VLAN Monitor on, the following additional guidelines apply:
All external ports in all trunks that are added to a single failover trigger must have the same VLAN membership and have the same PVID.
Each failover trigger must operate on a different VLAN membership.
Multiple failover triggers cannot operate on the same internal port.
For each port in each trunk in a failover trigger, the trigger monitors the STP state only on the default PVID.
L2 Failover Configurations
is a simple example of Layer 2 Failover. One GbE Switch Module is the primary, and the other is used as a backup. In this example, all external ports on the primary switch belong to a single trunk group, with Layer 2 Failover enabled, and Failover Limit set to 2. If two or fewer links in trigger 1 remain active, the switch temporarily disables all internal serverblade ports that reside in VLAN 1. This action causes a failover event on Server 1 and Server
2.
Trigger 1
Primary
GbESM Server 1
Enterprise
Routing Switch
Trigger 1
Server 2
Server 3
Backup
GbESM
BladeCenter
Server 4
VLAN 1:
VLAN 2:
Figure 13-1 Basic Layer 2 Failover
220 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
shows a configuration with two trunks, each in a different Failover Trigger.
GbESM 1 is the primary switch for Server 1 and Server 2. GbESM 2 is the primary switch for
Server 3 and Server 4. VLAN Monitor is turned on. STP is turned off.
If all links go down in trigger 1, GbESM 1 disables all internal ports that reside in VLAN 1. If all links in trigger 2 go down, GbESM 1 disables all internal ports that reside in VLAN 2.
Trigger 1
GbESM 1
Server 1
Trigger 2
Server 2
Enterprise
Routing Switch
Trigger 1
Trigger 2
Server 3
GbESM 2
BladeCenter
VLAN 1:
VLAN 2:
Server 4
Figure 13-2 Two trunks, each in a different Failover Trigger
42C4911, January 2007 Chapter 13: High Availability 221
Alteon OS Application Guide
shows a configuration with two trunks. VLAN Monitor is turned off, so only one
Failover Trigger is configured on each switch. GbESM 1 is the primary switch for Server 1 and
Server 2. GbESM 2 is the primary switch for Server 3 and Server 4. STP is turned off.
If all links in trigger 1 go down, GbESM 1 disables all internal links to server blades.
Trigger 1
GbESM 1
Server 1
Enterprise
Routing Switch
Trigger 1
Server 2
Server 3
GbESM 2
BladeCenter
Server 4
VLAN 1:
VLAN 2:
Figure 13-3 Two trunks, one Failover Trigger
222 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
Configuring Trunk Failover
The following procedure pertains to example 1, as shown in
1.
Configure Network Adapter Teaming on the servers.
2.
Define a trunk group on the GbESM.
>> # /cfg/l2/trunk 1
>> Trunk group 1# add EXT1
>> Trunk group 1# add EXT2
>> Trunk group 1# add EXT3
>> Trunk group 1# ena
(Select trunk group 1)
(Add port EXT1 to trunk group 1)
(Add port EXT2 to trunk group 1)
(Add port EXT3 to trunk group 1)
(Enable trunk group 1)
3.
Configure Failover parameters.
>> # /cfg/failovr/on
>> Failover# trigger 1
>> Trigger 1# ena
>> Trigger 1# limit 2
>> Trigger 1# amon
>> Auto Monitor# addtrnk 1
4.
Apply and verify the configuration.
>> Auto Monitor# apply
>> Auto Monitor# cur
5.
Save your new configuration changes.
>> Auto Monitor# save
(Turn Failover on)
(Select trigger group 1)
(Enable trigger group 1)
(Set Failover limit to 2 links)
(Select Auto Monitor menu)
(Add trunk group 1)
(Make your changes active)
(View current trunking configuration)
(Save for restore after reboot)
42C4911, January 2007 Chapter 13: High Availability 223
Alteon OS Application Guide
VRRP Overview
In a high-availability network topology, no device can create a single point-of-failure for the network or force a single point-of-failure to any other part of the network. This means that your network will remain in service despite the failure of any single device. To achieve this usually requires redundancy for all vital network components.
VRRP enables redundant router configurations within a LAN, providing alternate router paths for a host to eliminate single points-of-failure within a network. Each participating VRRPcapable routing device is configured with the same virtual router IP address and ID number.
One of the virtual routers is elected as the master, based on a number of priority criteria, and assumes control of the shared virtual router IP address. If the master fails, one of the backup virtual routers will take control of the virtual router IP address and actively process traffic addressed to it.
With VRRP, Virtual Interface Routers (VIR) allow two VRRP routers to share an IP interface across the routers. VIRs provide a single Destination IP (DIP) for upstream routers to reach various servers, and provide a virtual default Gateway for the server blades.
VRRP Components
Each physical router running VRRP is known as a VRRP router.
Virtual Router
Two or more VRRP routers can be configured to form a virtual router (RFC 2338). Each
VRRP router may participate in one or more virtual routers. Each virtual router consists of a user-configured virtual router identifier (VRID) and an IP address.
Virtual Router MAC Address
The VRID is used to build the virtual router MAC Address. The five highest-order octets of the virtual router MAC Address are the standard MAC prefix (00-00-5E-00-01) defined in RFC
2338. The VRID is used to form the lowest-order octet.
Owners and Renters
Only one of the VRRP routers in a virtual router may be configured as the IP address owner.
This router has the virtual router’s IP address as its real interface address. This router responds to packets addressed to the virtual router’s IP address for ICMP pings, TCP connections, and so on.
224 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
There is no requirement for any VRRP router to be the IP address owner. Most VRRP installations choose not to implement an IP address owner. For the purposes of this chapter, VRRP routers that are not the IP address owner are called renters.
Master and Backup Virtual Router
Within each virtual router, one VRRP router is selected to be the virtual router master. See
“Selecting the Master VRRP Router” on page 226
for an explanation of the selection process.
N OTE – If the IP address owner is available, it will always become the virtual router master.
The virtual router master forwards packets sent to the virtual router. It also responds to Address
Resolution Protocol (ARP) requests sent to the virtual router's IP address. Finally, the virtual router master sends out periodic advertisements to let other VRRP routers know it is alive and its priority.
Within a virtual router, the VRRP routers not selected to be the master are known as virtual router backups. Should the virtual router master fail, one of the virtual router backups becomes the master and assumes its responsibilities.
Virtual Interface Router
At Layer 3, a Virtual Interface Router (VIR) allows two VRRP routers to share an IP interface across the routers. VIRs provide a single Destination IP (DIP) for upstream routers to reach various destination networks, and provide a virtual default Gateway.
N
OTE
– Every VIR must be assigned to an IP interface, and every IP interface must be assigned to a VLAN. If no port in a VLAN has link up, the IP interface of that VLAN is down, and if the
IP interface of a VIR is down, that VIR goes into INIT state.
42C4911, January 2007 Chapter 13: High Availability 225
Alteon OS Application Guide
VRRP Operation
Only the virtual router master responds to ARP requests. Therefore, the upstream routers only forward packets destined to the master. The master also responds to ICMP ping requests. The backup does not forward any traffic, nor does it respond to ARP requests.
If the master is not available, the backup becomes the master and takes over responsibility for packet forwarding and responding to ARP requests.
Selecting the Master VRRP Router
Each VRRP router is configured with a priority between 1–254. A bidding process determines which VRRP router is or becomes the master—the VRRP router with the highest priority.
The master periodically sends advertisements to an IP multicast address. As long as the backups receive these advertisements, they remain in the backup state. If a backup does not receive an advertisement for three advertisement intervals, it initiates a bidding process to determine which VRRP router has the highest priority and takes over as master.
If, at any time, a backup determines that it has higher priority than the current master does, it can preempt the master and become the master itself, unless configured not to do so. In preemption, the backup assumes the role of master and begins to send its own advertisements. The current master sees that the backup has higher priority and will stop functioning as the master.
A backup router can stop receiving advertisements for one of two reasons—the master can be down, or all communications links between the master and the backup can be down. If the master has failed, it is clearly desirable for the backup (or one of the backups, if there is more than one) to become the master.
N OTE – If the master is healthy but communication between the master and the backup has failed, there will then be two masters within the virtual router. To prevent this from happening, configure redundant links to be used between the switches that form a virtual router.
226 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
Failover Methods
With service availability becoming a major concern on the Internet, service providers are increasingly deploying Internet traffic control devices, such as application switches, in redundant configurations. Traditionally, these configurations have been hot-standby configurations, where one switch is active and the other is in a standby mode.
A non-VRRP hot-standby configuration is shown in the figure below:
Primary Switch
IP: 200.200.200.100
Internet
Servers
Secondary Switch
IP: 200.200.200.101
Figure 13-4 A Non-VRRP, Hot-Standby Configuration
While hot-standby configurations increase site availability by removing single points-of-failure, service providers increasingly view them as an inefficient use of network resources because one functional application switch sits by idly until a failure calls it into action. Service providers now demand that vendors' equipment support redundant configurations where all devices can process traffic when they are healthy, increasing site throughput and decreasing user response times when no device has failed.
Alteon OS high availability configurations are based on VRRP. The Alteon OS implementation of VRRP includes proprietary extensions.
The Alteon OS implementation of VRRP supports the following modes of high availability:
Active-Active—based on proprietary Alteon OS extensions to VRRP
Hot-Standby—supports Network Adapter Teaming on your server blades
42C4911, January 2007 Chapter 13: High Availability 227
Alteon OS Application Guide
Active-Active Redundancy
In an active-active configuration, shown in Figure 13-5
, two switches provide redundancy for each other, with both active at the same time. Each switch processes traffic on a different subnet. When a failure occurs, the remaining switch can process traffic on all subnets.
For a configuration example, see
“Active-Active Configuration” on page 233 .
Active (subnet A and C)
GbESM 1
Servers
Enterprise
Routing Switch
GbESM 2
Active (subnet B and D)
Figure 13-5 Active-Active Redundancy
228 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
Hot-Standby Redundancy
The primary application for VRRP-based hot-standby is to support Server Load Balancing when you have configured Network Adapter Teaming on your server blades. With Network
Adapter Teaming, the NICs on each server share the same IP address, and are configured into a team. One NIC is the primary link, and the others are backup links. For more details, refer to the NetXen 10 Gb Ethernet Adapter documentation.
The hot-standby model is shown in
.
Active
GbESM 1
10.10.10.1
Interswitch
Link
Enterprise
Routing Switch
GbESM 2
Standby
Figure 13-6 Hot-Standby Redundancy
10.10.10.2
Virtual Router Group
The virtual router group ties all virtual routers on the switch together as a single entity. By definition, hot-standby requires that all virtual routers failover as a group, and not individually. As members of a group, all virtual routers on the switch (and therefore the switch itself), are in either a master or standby state.
The virtual router group cannot be used for active-active configurations or any other configuration that require shared interfaces.
A VRRP group has the following characteristics:
When enabled, all virtual routers behave as one entity, and all group settings override any individual virtual router settings.
All individual virtual routers, once the VRRP group is enabled, assume the group’s tracking and priority.
When one member of a VRRP group fails, the priority of the group decreases, and the state of the entire switch changes from Master to Standby.
Each VRRP advertisement can include up to 128 addresses. All virtual routers are advertised within the same packet, conserving processing and buffering resources.
42C4911, January 2007 Chapter 13: High Availability 229
Alteon OS Application Guide
Alteon OS extensions to VRRP
This section describes the following VRRP enhancements that are implemented in Alteon OS:
Tracking VRRP Router Priority
Tracking VRRP Router Priority
Alteon OS supports a tracking function that dynamically modifies the priority of a VRRP router, based on its current state. The objective of tracking is to have, whenever possible, the master bidding processes for various virtual routers in a LAN converge on the same switch.
Tracking ensures that the selected switch is the one that offers optimal network performance.
For tracking to have any effect on virtual router operation, pre-emption must be enabled.
Alteon OS can track the attributes listed in
:
Table 13-1 VRRP Tracking Parameters
Parameter Description
Number of IP interfaces on the switch that are active (“up”)
/cfg/l3/vrrp/track/ifs
Helps elect the virtual routers with the most available routes as the master. (An IP interface is considered active when there is at least one active port on the same VLAN.)
This parameter influences the VRRP router's priority in virtual interface routers.
Number of active ports on the same VLAN
/cfg/l3/vrrp/track/ports
Helps elect the virtual routers with the most available ports as the master. This parameter influences the VRRP router's priority in virtual interface routers.
Note: In a hot-standby configuration, only external ports are tracked.
Number of virtual routers in master mode on the switch
/cfg/l3/vrrp/track/vr
Useful for ensuring that traffic for any particular client/ server pair is handled by the same switch, increasing routing efficiency. This parameter influences the VRRP router's priority in virtual interface routers.
Each tracked parameter has a user-configurable weight associated with it. As the count associated with each tracked item increases (or decreases), so does the VRRP router's priority, subject to the weighting associated with each tracked item. If the priority level of a standby is greater than that of the current master, then the standby can assume the role of the master.
See “Configuring the Switch for Tracking” on page 231
for an example on how to configure the switch for tracking VRRP priority.
230 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
Virtual Router Deployment Considerations
Review the following issues described in this section to prevent network problems when deploying virtual routers:
Assigning VRRP Virtual Router ID
Configuring the Switch for Tracking
Assigning VRRP Virtual Router ID
During the software upgrade process, VRRP virtual router IDs will be automatically assigned if failover is enabled on the switch. When configuring virtual routers at any point after upgrade, virtual router ID numbers (/cfg/l3/vrrp/vr # /vrid ) must be assigned. The virtual router ID may be configured as any number between 1 and 255.
Configuring the Switch for Tracking
Tracking configuration largely depends on user preferences and network environment. Consider the configuration shown in
. Assume the following behavior on the network:
Switch 1 is the master router upon initialization.
If switch 1 is the master and it has one fewer active servers than switch 2, then switch 1 remains the master.
This behavior is preferred because running one server down is less disruptive than bringing a new master online and severing all active connections in the process.
If switch 1 is the master and it has two or more active servers fewer than switch 2, then switch 2 becomes the master.
If switch 2 is the master, it remains the master even if servers are restored on switch 1 such that it has one fewer or an equal number of servers.
If switch 2 is the master and it has one active server fewer than switch 1, then switch 1 becomes the master.
42C4911, January 2007 Chapter 13: High Availability 231
Alteon OS Application Guide
The user can implement this behavior by configuring the switch for tracking as follows:
1.
Set the priority for switch 1 to 101.
2.
Leave the priority for switch 2 at the default value of 100.
3.
On both switches, enable tracking based on ports (ports), interfaces (ifs), or virtual routers (vr). You can choose any combination of tracking parameters, based on your network configuration.
N OTE – There is no shortcut to setting tracking parameters. The goals must first be set and the outcomes of various configurations and scenarios analyzed to find settings that meet the goals.
232 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
High Availability Configurations
GbE Switch Modules offer flexibility in implementing redundant configurations. This section discusses the more useful and easily deployed configurations:
“Active-Active Configuration” on page 233
“Hot-Standby Configuration” on page 238
Active-Active Configuration
shows an example configuration where two GbE Switch Modules are used as
VRRP routers in an active-active configuration. In this configuration, both switches respond to packets.
Enterprise
Routing Switch
L2 Switch
L2 Switch
VIR 1: 192.168.1.200 (Master)
VIR 2: 192.168.2.200 (Backup)
1
2
GbESM 1
5
Server 1
NIC 1: 10.0.1.1/24
NIC 2: 10.0.2.1/24
Server 2
NIC 1: 10.0.1.2/24
NIC 2: 10.0.2.2/24
Server 3
NIC 1: 10.0.1.3/24
NIC 2: 10.0.2.3/24
5
1
2
GbESM 2
Server 4
NIC 1: 10.0.1.4/24
NIC 2: 10.0.2.4/24
VIR 1: 192.168.1.200 (Backup)
VIR 2: 192.168.2.200 (Master)
Figure 13-7 Active-Active High-Availability Configuration
Although this example shows only two switches, there is no limit on the number of switches used in a redundant configuration. It is possible to implement an active-active configuration across all the VRRP-capable switches in a LAN.
Each VRRP-capable switch in an active-active configuration is autonomous. Switches in a virtual router need not be identically configured.
In the scenario illustrated in Figure 13-7
, traffic destined for IP address 10.0.1.1 is forwarded through the Layer 2 switch at the top of the drawing, and ingresses GbESM 1 on port EXT1.
Return traffic uses default gateway 1 (192.168.1.1). If the link between GbESM 1 and the
Layer 2 switch fails, GbESM 2 becomes the Master because it has a higher priority. Traffic is forwarded to GbESM 2, which forwards it to GbESM 1 through port EXT5. Return traffic uses default gateway 2 (192.168.2.1), and is forwarded through the Layer 2 switch at the bottom of the drawing.
To implement the active-active example, perform the following switch configuration.
42C4911, January 2007 Chapter 13: High Availability 233
Alteon OS Application Guide
Task 1: Configure GbESM 1
1.
Configure client and server interfaces.
/cfg/l3/if 1
>> IP Interface 1# addr 192.168.1.100
>> IP Interface 1# vlan 10
>> IP Interface 1# ena
>> IP Interface 1# ..
>> Layer 3# if 2
>> IP Interface 2# addr 192.168.2.101
>> IP Interface 2# vlan 20
>> IP Interface 2# ena
>> IP Interface 2# ..
>> Layer 3# if 3
>> IP Interface 3# addr 10.0.1.100
>> IP Interface 3# mask 255.255.255.0
>> IP Interface 3# ena
>> IP Interface 3# ..
>> Layer 3# if 4
>> IP Interface 4# addr 10.0.2.101
>> IP Interface 4# mask 255.255.255.0
>> IP Interface 4# ena
(Select interface 1)
(Define IP address for interface 1)
(Assign VLAN 10 to interface 1)
(Enable interface 1)
(Select interface 2)
(Define IP address for interface 2)
(Assign VLAN 20 to interface 2)
(Enable interface 2)
(Select interface 3)
(Define IP address for interface 3)
(Define subnet mask for interface 3)
(Enable interface 3)
(Select interface 4)
(Define IP address for interface 4)
(Define subnet mask for interface 4)
(Enable interface 4)
2.
Configure the default gateways. Each default gateway points to a Layer 3 router.
/cfg/l3/gw 1
>> Default gateway 1# addr 192.168.1.1
>> Default gateway 1# ena
>> Default gateway 1# ..
>> Layer 3# gw 2
>> Default gateway 2# addr 192.168.2.1
>> Default gateway 2# ena
(Select default gateway 1)
(Point gateway to the first L3 router)
(Enable the default gateway)
(Select default gateway 2)
(Point gateway to the second router)
(Enable the default gateway)
234 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
3.
Turn on VRRP and configure two Virtual Interface Routers.
/cfg/l3/vrrp/on (Turn VRRP on)
>> Virtual Router Redundancy Protocol# vr 1 (Select virtual router 1)
>> VRRP Virtual Router 1# vrid 1
>> VRRP Virtual Router 1# if 1
(Set VRID to 1)
(Set interface 1)
>> VRRP Virtual Router 1# addr 192.168.1.200 (Define IP address)
>> VRRP Virtual Router 1# ena (Enable virtual router 1)
>> VRRP Virtual Router 1# .. (Enable virtual router 1)
>> Virtual Router Redundancy Protocol# vr 2 (Select virtual router 2)
>> VRRP Virtual Router 2# vrid 2
>> VRRP Virtual Router 2# if 2
(Set VRID to 2)
(Set interface 2)
>> VRRP Virtual Router 2# addr 192.168.2.200 (Define IP address)
>> VRRP Virtual Router 2# ena (Enable virtual router 2)
4.
Enable tracking on ports. Set the priority of Virtual Router 1 to 101, so that it becomes the Master.
/cfg/l3/vrrp/vr 1 (Select VRRP virtual router 1)
>> VRRP Virtual Router 1# track/ports/ena (Set tracking on ports)
>> VRRP Virtual Router 1 Priority Tracking# ..
>> VRRP Virtual Router 1# prio 101 (Set the VRRP priority)
>> VRRP Virtual Router 1# ..
>> Virtual Router Redundancy Protocol# vr 2 (Select VRRP virtual router 2)
>> VRRP Virtual Router 1# track/ports/ena (Set tracking on ports)
5.
Configure ports.
/cfg/l2/vlan 10
>> VLAN 10# ena
>> VLAN 10# add ext1
>> VLAN 10# ..
>> Layer 2# vlan 20
>> VLAN 20# ena
>> VLAN 20# add ext2
6.
Turn off Spanning Tree Protocol globally.
/cfg/l2/stg 1/off
>> Spanning Tree Group 1# apply
>> Spanning Tree Group 1# save
(Select VLAN 10)
(Enable VLAN 10)
(Add port EXT 1 to VLAN 10)
(Select VLAN 20)
(Enable VLAN 20)
(Add port EXT 2 to VLAN 20)
(Turn off STG)
42C4911, January 2007 Chapter 13: High Availability 235
Alteon OS Application Guide
Task 2: Configure GbESM 2
1.
Configure client and server interfaces.
/cfg/l3/if 1
>> IP Interface 1# addr 192.168.1.101
>> IP Interface 1# vlan 10
>> IP Interface 1# ena
>> IP Interface 1# ..
>> Layer 3# if 2
>> IP Interface 2# addr 192.168.2.100
>> IP Interface 2# vlan 20
>> IP Interface 2# ena
>> IP Interface 2# ..
>> Layer 3# if 3
>> IP Interface 3# addr 10.0.1.101
>> IP Interface 3# mask 255.255.255.0
>> IP Interface 3# ena
>> IP Interface 3# ..
>> Layer 3# if 4
>> IP Interface 4# addr 10.0.2.100
>> IP Interface 4# mask 255.255.255.0
>> IP Interface 4# ena
(Select interface 1)
(Define IP address for interface 1)
(Assign VLAN 10 to interface 1)
(Enable interface 1)
(Select interface 2)
(Define IP address for interface 2)
(Assign VLAN 20 to interface 2)
(Enable interface 2)
(Select interface 3)
(Define IP address for interface 3)
(Define subnet mask for interface 3)
(Enable interface 3)
(Select interface 4)
(Define IP address for interface 4)
(Define subnet mask for interface 4)
(Enable interface 4)
2.
Configure the default gateways. Each default gateway points to a Layer 3 router.
/cfg/l3/gw 1
>> Default gateway 1# addr 192.168.2.1
>> Default gateway 1# ena
>> Default gateway 1# ..
>> Layer 3# gw 2
>> Default gateway 2# addr 192.168.1.1
>> Default gateway 2# ena
(Select default gateway 1)
(Point gateway to the first L3 router)
(Enable the default gateway)
(Select default gateway 2)
(Point gateway to the second router)
(Enable the default gateway)
236 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
3.
Turn on VRRP and configure two Virtual Interface Routers.
/cfg/l3/vrrp/on (Turn VRRP on)
>> Virtual Router Redundancy Protocol# vr 1 (Select virtual router 1)
>> VRRP Virtual Router 1# vrid 1
>> VRRP Virtual Router 1# if 1
(Set VRID to 1)
(Set interface 1)
>> VRRP Virtual Router 1# addr 192.168.1.200 (Define IP address)
>> VRRP Virtual Router 1# ena (Enable virtual router 1)
>> VRRP Virtual Router 1# .. (Enable virtual router 1)
>> Virtual Router Redundancy Protocol# vr 2 (Select virtual router 2)
>> VRRP Virtual Router 2# vrid 2
>> VRRP Virtual Router 2# if 2
(Set VRID to 2)
(Set interface 2)
>> VRRP Virtual Router 2# addr 192.168.2.200 (Define IP address)
>> VRRP Virtual Router 2# ena (Enable virtual router 2)
4.
Enable tracking on ports. Set the priority of Virtual Router 2 to 101, so that it becomes the Master.
/cfg/l3/vrrp/vr 1 (Select VRRP virtual router 1)
>> VRRP Virtual Router 1# track/ports/ena (Set tracking on ports)
>> VRRP Virtual Router 1 Priority Tracking# ..
>> VRRP Virtual Router 1# ..
>> Virtual Router Redundancy Protocol# vr 2 (Select VRRP virtual router 2)
>> VRRP Virtual Router 2# track/ports/ena (Set tracking on ports)
>> VRRP Virtual Router 2 Priority Tracking# ..
>> VRRP Virtual Router 2# prio 101 (Set the VRRP priority)
5.
Configure ports.
/cfg/l2/vlan 10
>> VLAN 10# ena
>> VLAN 10# add ext1
>> VLAN 10# ..
>> Layer 2# vlan 20
>> VLAN 20# ena
>> VLAN 20# add ext2
(Select VLAN 10)
(Enable VLAN 10)
(Add port EXT 1 to VLAN 10)
(Select VLAN 20)
(Enable VLAN 20)
(Add port EXT 2 to VLAN 20)
6.
Turn off Spanning Tree Protocol globally. Apply and save changes.
(Turn off STG) /cfg/l2/stg 1/off
>> Spanning Tree Group 1# apply
>> Spanning Tree Group 1# save
42C4911, January 2007 Chapter 13: High Availability 237
Alteon OS Application Guide
Hot-Standby Configuration
The primary application for VRRP-based hot-standby is to support Network Adapter Teaming on your server blades. With Network Adapter Teaming, the NICs on each server share the same IP address, and are configured into a team. One NIC is the primary link, and the others are backup links. For more details, refer to the NetXen 10 Gb Ethernet Adapter documentation.
A hot-standby configuration allows all processes to failover to a standby switch if any type of failure should occur. All Virtual Interface Routers (VIRs) are bundled into one Virtual Router group, and then they failover together. When there is a failure that causes the VRRP Master to failover to the Standby, then the original primary switch temporarily disables the internal server links, which, in turn, causes the NIC teams to failover as well.
N OTE – When using hot-standby redundancy, peer switches should have an equal number of connected ports.
If hot-standby is implemented in a looped environment, the hot-standby feature automatically disables the hot-standby ports on the VRRP Standby. If the Master switch should failover to the Standby switch, it would change the hot-standby ports from disabled to forwarding, without relying on Spanning Tree or manual intervention. Therefore, Spanning Tree must be disabled.
238 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
illustrates a common hot-standby implementation on a single blade server. Notice that the BladeCenter server NICs are configured into a team that shares the same IP address across both NICs. Because only one link can be active at a time, the hot-standby feature controls the NIC failover by having the Standby switch disable its internal ports (holding down the server links).
IF 1: 174.14.20.110
IF 2: 10.1.1.110
VIR 1: 174.14.20.100
VIR 2: 10.1.1.100
Active
GbESM 1
Server 1
NIC 1 IP = 10.0.1.1
Enterprise
Routing Switch
Hot Standby
GbESM 2
IF 1: 174.14.20.111
IF 2: 10.1.1.111
VIR 1: 174.14.20.100
VIR 2: 10.1.1.100
Server 2
NIC 1 IP = 10.0.1.2
= Active Links
= Standby Links
Figure 13-8 Hot-Standby Configuration
Task 1: Configure GbESM 1
1.
On GbESM 1, configure the interfaces for clients (174.14.20.110) and servers (10.1.1.110).
/cfg/l3/if 1
>> IP Interface 1# addr 174.14.20.110
>> IP Interface 1# ena
>> IP Interface 1# ..
>> Layer 3# if 2
>> IP Interface 2# addr 10.1.1.110
>> IP Interface 2# ena
(Define IP address for interface 1)
(Enable interface 1)
(Define IP address for interface 2)
(Enable interface 2)
42C4911, January 2007 Chapter 13: High Availability 239
Alteon OS Application Guide
2.
Configure Virtual Interface Routers.
/cfg/l3/vrrp/on (Turn on VRRP)
>> Virtual Router Redundancy Protocol# vr 1 (Select Virtual Router 1)
>> VRRP Virtual Router 1# ena
>> VRRP Virtual Router 1# vrid 1
(Enable VR 1)
(Select the Virtual Router ID)
>> VRRP Virtual Router 1# if 1 (Select interface for VR 1)
>> VRRP Virtual Router 1# addr 174.14.20.100 (Define IP address for VR 1)
>> VRRP Virtual Router 1# ..
>> Virtual Router Redundancy Protocol# vr 2 (Select Virtual Router 2)
>> VRRP Virtual Router 2# ena
>> VRRP Virtual Router 2# vrid 2
(Enable VR 2)
(Select the Virtual Router ID)
>> VRRP Virtual Router 2# if 2 (Select interface for VR 2)
>> VRRP Virtual Router 2# addr 10.1.1.100 (Define IP address for VR 2)
3.
Enable VRRP Hot Standby.
/cfg/l3/vrrp/hotstan ena (Enable Hot Standby)
4.
Configure VRRP Group parameters. Set the VRRP priority to 101, so that this switch is the Master.
/cfg/l3/vrrp/group
>> VRRP Virtual Router Group# ena
>> VRRP Virtual Router Group# vrid 1
(Enable Virtual Router Group)
(Set Virtual Router ID for Group)
>> VRRP Virtual Router Group# if 1
>> VRRP Virtual Router Group# prio 101
(Set interface for Group)
(Set VRRP priority to 101)
>> VRRP Virtual Router Group# track/ports ena (Enable tracking on ports)
5.
Turn off Spanning Tree Protocol globally. Apply and save changes.
/cfg/l2/stg 1/off
>> Spanning Tree Group 1# apply
>> Spanning Tree Group 1# save
(Turn off Spanning Tree)
(Apply changes)
240 Chapter 13: High Availability 42C4911, January 2007
Alteon OS Application Guide
Task 2: Configure GbESM 2
1.
On GbESM 1, configure the interfaces for clients (174.14.20.111) and servers (10.1.1.111).
/cfg/l3/if 1
>> IP Interface 1# addr 174.14.20.111
>> IP Interface 1# ena
>> IP Interface 1# ..
>> Layer 3# if 2
>> IP Interface 2# addr 10.1.1.111
>> IP Interface 2# ena
(Define IP address for interface 1)
(Enable interface 1)
(Define IP address for interface 2)
(Enable interface 2)
2.
Configure Virtual Interface Routers.
/cfg/l3/vrrp/on (Turn on VRRP)
>> Virtual Router Redundancy Protocol# vr 1 (Select Virtual Router 1)
>> VRRP Virtual Router 1# ena
>> VRRP Virtual Router 1# vrid 1
(Enable VR 1)
(Select the Virtual Router ID)
>> VRRP Virtual Router 1# if 1 (Select interface for VR 1)
>> VRRP Virtual Router 1# addr 174.14.20.100 (Define IP address for VR 1)
>> VRRP Virtual Router 1# ..
>> Virtual Router Redundancy Protocol# vr 2 (Select Virtual Router 2)
>> VRRP Virtual Router 2# ena
>> VRRP Virtual Router 2# vrid 2
(Enable VR 2)
(Select the Virtual Router ID)
>> VRRP Virtual Router 2# if 2 (Select interface for VR 2)
>> VRRP Virtual Router 2# addr 10.1.1.100 (Define IP address for VR 2)
3.
Enable VRRP Hot Standby.
/cfg/l3/vrrp/hotstan ena (Enable Hot Standby)
4.
Configure VRRP Group parameters. Use the default VRRP priority of 100, so that this switch is the Standby.
/cfg/l3/vrrp/group
>> VRRP Virtual Router Group# ena
>> VRRP Virtual Router Group# vrid 1
(Enable Virtual Router Group)
(Set Virtual Router ID for Group)
>> VRRP Virtual Router Group# if 1 (Set interface for Group)
>> VRRP Virtual Router Group# track/ports ena (Enable tracking on ports)
42C4911, January 2007 Chapter 13: High Availability 241
Alteon OS Application Guide
5.
Turn off Spanning Tree Protocol globally. Apply and save changes.
/cfg/l2/stg 1/off
>> Spanning Tree Group 1# apply
>> Spanning Tree Group 1# save
(Turn off Spanning Tree)
(Apply changes)
242 Chapter 13: High Availability 42C4911, January 2007
Part 4: Appendices
This section describes the following topics:
Troubleshooting
RADIUS Server Configuration Notes
Glossary
42C4911, January 2007
Alteon OS Application Guide
244 42C4911, January 2007
A PPENDIX A
Troubleshooting
This section discusses some tools to help you troubleshoot common problems on the GbE
Switch Module:
“Monitoring Ports” on page 246
42C4911, January 2007 245
Alteon OS Application Guide
Monitoring Ports
The port mirroring feature in the Alteon OS allows you to attach a sniffer to a monitoring port that is configured to receive a copy of all packets that are forwarded from the mirrored port.
Alteon OS enables you to mirror port traffic for all layer 2 and layer 3. Port mirroring can be used as a troubleshooting tool or to enhance the security of your network. For example, an IDS server can be connected to the monitor port to detect intruders attacking the network.
As shown in
Figure A-1 , port EXT3 is monitoring ingress traffic (traffic entering the switch)
on port EXT1 and egress traffic (traffic leaving the switch) on port EXT2. You can attach a device to port EXT3 to monitor the traffic on ports EXT1 and EXT2.
Ingress
Egress
Mirrored ports
Monitoring port
Figure A-1 Monitoring Ports
Figure A-1 shows two mirrored ports monitored by a single port. Similarly, you can have a sin-
gle or groups of:
one mirrored port to one monitored port
more than two mirrored ports to one monitored port
Alteon OS does not support a single port being monitored by multiple ports.
Ingress and egress traffic is duplicated and sent to the monitor port after processing.
N OTE – The GbESM cannot mirror LACPDU packets.
246 Appendix A: Troubleshooting 42C4911, January 2007
Alteon OS Application Guide
N OTE – Traffic on VLAN 4095 is not mirrored to the external ports.
Port Mirroring behavior
This section describes the composition of monitored packets in the GbE Switch Module, based on the configuration of the ports.
If a tagged port's PVID is the same as its VLAN ID, then the egress traffic on that port is untagged. Therefore, the following port-mirroring cases are differentiated, as described below:
Tagged or untagged frames from mirrored ports whose VLAN ID is the same as the monitoring port's PVID: mirrored frames viewed at the monitoring port are untagged
Tagged or untagged frames from mirrored ports whose VLAN ID is different than the monitoring port's PVID: mirrored frames viewed at the monitoring port are tagged with the VLAN ID of ingress/egress port for ingress/egress mirroring respectively.
Layer 2 Port Mirroring
In this scenario, you observe Layer 2 port mirroring.
Same VLAN as Mirrored Port
Both ports tagged: Tagged packet with VID of the VLAN to which the ports belong
Mirrored port tagged, Monitoring port untagged: Untagged packet
Mirrored port untagged, Monitoring port tagged: Tagged packet with VID of the
VLAN to which both ports belong
Both ports untagged: Untagged packet
Different VLAN from Mirrored Port
Both ports tagged: Tagged packet with VID of mirrored port
Mirrored port tagged, Monitoring port untagged: Tagged packet with VID of mirrored port
Mirrored port untagged, Monitoring port tagged: Tagged packet with VID of mirrored port
Both ports untagged: Tagged packet with VID of mirrored port
42C4911, January 2007 Appendix A: Troubleshooting 247
Alteon OS Application Guide
Layer 3 Port Mirroring
(Monitoring Port and Egress Port in the same GEA)
In this scenario, you observe Layer 3 port mirroring on an egress port, and both the egress port and the monitoring port are in the same Gigabit Ethernet Aggregator (GEA) unit. To find out which GEA unit each port resides on, use the /info/geaport command.
The monitoring port always shows a tagged packet with a VLAN ID (VID) of the egress port.
N OTE – In general, the GbESM mirrors all Layer 3 ingress packets after the packets are routed, that is, all Layer 3 packets observed at the monitoring port have source MAC address, destination MAC address, VLAN, TTL, IP checksum changed as if they have gone through the routing process to the egress port.
248 Appendix A: Troubleshooting 42C4911, January 2007
Alteon OS Application Guide
Layer 3 Port Mirroring (Both Ports in Different GEAs)
In this scenario, you observe Layer 3 port mirroring on an egress port, but the egress port and the monitoring port reside on different Gigabit Ethernet Aggregator (GEA) units. To find out which GEA unit each port resides on, use the /info/geaport command.
N OTE – In general, the GbESM mirrors all Layer 3 ingress packets after the packets are routed, that is, all Layer 3 packets observed at the monitoring port have source MAC address, destination MAC address, VLAN, TTL, IP checksum changed as if they have gone through the routing process to the egress port.
Same VLAN as Mirrored Port
Both ports tagged: Tagged packet with VID of the VLAN to which the ports belong
Mirrored port tagged, Monitoring port untagged: Untagged packet
Mirrored port untagged, Monitoring port tagged: Tagged packet with VID of the
VLAN to which the ports belong
Both ports untagged: Untagged packet
Different VLAN from Mirrored Port
Both ports tagged: Tagged packet with VID of the VLAN to which the ports belong
Mirrored port tagged, Monitoring port untagged: Tagged packet with VID of the
VLAN to which the ports belong
Mirrored port untagged, Monitoring port tagged: Tagged packet with VID of the
VLAN to which the ports belong
Both ports untagged: Tagged packet with VID of the VLAN to which the ports belong
N
OTE
– When the monitoring port belongs to a different VLAN, all mirrored packets have an 802.1q tag field with the VID of the VLAN to which the mirrored port belongs. The VID included in the tag field depends on which port is monitored.
For example, assume a packet traverses from port EXT1 (VLAN 1) to EXT2 (VLAN 2), and is monitored on port EXT3. When you monitor EXT1, the packet’s tag includes the VID of
VLAN 1. When you monitor EXT2, the packet’s tag includes the VID of VLAN 2.
42C4911, January 2007 Appendix A: Troubleshooting 249
Alteon OS Application Guide
Layer 3 Port Mirroring
(MP Packets, Both Ports in the Same GEA)
MP packets are generated by the management processor, such as routing packets between direct interfaces. In this scenario, the mirrored port and the monitoring port reside on the same
Gigabit Ethernet Aggregator (GEA) unit. To find out which GEA unit each port resides on, use the /info/geaport command.
The monitoring port always shows a tagged packet with a VLAN ID (VID) of the ingress port.
Layer 3 Port Mirroring
(MP Packets, Mirrored Port and Monitoring Port in Different GEAs)
MP packets are generated by the management processor, such as a ping to the switch interfaces. In this scenario, the mirrored port and the monitoring port reside on different Gigabit
Ethernet Aggregator (GEA) units. To find out which GEA unit each port resides on, use the /info/geaport command.
N OTE – The switch doesn’t monitor Layer 3 egress-routed packets from the MP when the mirror port and the monitoring port are in different VLANs.
Same VLAN as Mirrored Port
Both ports tagged: Tagged packet with VID of the VLAN to which the ports belong
Mirrored port tagged, Monitoring port untagged: Untagged packet
Mirrored port untagged, Monitoring port tagged: Tagged packet with VID of the
VLAN to which the ports belong
Both ports untagged: Untagged packet
Different VLAN from Mirrored Port
Both ports tagged: Tagged packet with VID of the VLAN to which the ports belong
Mirrored port tagged, Monitoring port untagged: Tagged packet with VID of the
VLAN to which the ports belong
Mirrored port untagged, Monitoring port tagged: Tagged packet with VID of the
VLAN to which the ports belong
Both ports untagged: Tagged packet with VID of the VLAN to which the ports belong
N
OTE
– When the monitoring port belongs to a different VLAN, all mirrored packets have an 802.1q tag field with the VID of the VLAN to which the mirrored port belongs. The VID included in the tag field depends on which port is monitored.
For example, assume a packet traverses from port EXT1 (VLAN 1) to EXT2 (VLAN 2), and is monitored on port EXT3. When you monitor EXT1, the packet’s tag includes the VID of
VLAN 1. When you monitor EXT2, the packet’s tag includes the VID of VLAN 2.
250 Appendix A: Troubleshooting 42C4911, January 2007
Alteon OS Application Guide
Configuring Port Mirroring
To configure port mirroring for the example shown in
,
1.
Specify the monitoring port.
>> # /cfg/pmirr/ monport EXT3 (Select port EXT3 for monitoring)
2.
Select the ports that you want to mirror.
>> Port EXT3 # add EXT1 (Select port EXT1 to mirror)
>> Enter port mirror direction [in, out, or both]: in
(Monitor ingress traffic on port EXT1)
>> Port EXT3 # add EXT2 (Select port EXT2 to mirror)
>> Enter port mirror direction [in, out, or both]: out
(Monitor egress traffic on port EXT2)
3.
Enable port mirroring.
>> # /cfg/pmirr/mirr ena (Enable port mirroring)
4.
Apply and save the configuration.
>> PortMirroring# apply
>> PortMirroring# save
(Apply the configuration)
(Save the configuration)
42C4911, January 2007 Appendix A: Troubleshooting 251
Alteon OS Application Guide
5.
View the current configuration.
>> PortMirroring# cur
Port mirroring is enabled
Monitoring Ports Mirrored Ports
INT1
INT2
INT3
INT4 none none none none none INT5
-----
-----
-----
EXT1
EXT2
EXT3
EXT4
EXT5
EXT6
(Display the current settings) none none
(EXT1, in) (EXT2, out) none none none
252 Appendix A: Troubleshooting 42C4911, January 2007
A PPENDIX B
RADIUS Server Configuration Notes
Use the following information to modify your RADIUS configuration files for the Nortel
Networks BaySecure Access Control RADIUS server, to provide authentication for users of the GbE Switch Module.
1.
Create a dictionary file called alteon.dct, with the following content:
###################################################################
# alteon.dct - RADLINX Alteon dictionary
#
# (See README.DCT for more details on the format of this file)
###################################################################
#
# Use the Radius specification attributes in lieu of the
# RADLINX Alteon ones
#
@radius.dct
#
# Define additional RADLINX Alteon parameters
# (add RADLINX Alteon specific attributes below)
ATTRIBUTE Radlinx-Vendor-Specific 26 [vid=648 data=string] R
##################################################################
# alteon.dct - RADLINX Alteon dictionary
###################################################################
#Define Alteon GbESM Layer 2 & Layer 3 dictionary
#@radius.dct
@alteon.dct
VALUE
VALUE
Service-Type
Service-Type user oper
255
252
##################################################################
42C4911, January 2007 253
Alteon OS Application Guide
2.
Open the dictiona.dcm file, and add the following line (as in the example):
@alteon.dct
###################################################################
# dictiona.dcm
###################################################################
# Generic Radius
@radius.dct
#
# Specific Implementations (vendor specific)
#
@pprtl2l3.dct
@acc.dct
@accessbd.dct
@alteon.dct
.
.
.
##################################################################
# dictiona.dcm
##################################################################
3.
Open the vendor file (vendor.ini), and add the following data to the Vendor-Product identification list: vendor-product = Alteon Blade-server module dictionary = alteon ignore-ports = no help-id = 0
254 Appendix B: RADIUS Server Configuration Notes 42C4911, January 2007
Glossary
DIP (Destination IP
Address)
Dport (Destination
Port)
The destination IP address of a frame.
The destination port (application socket: for example, http-80/https-443/DNS-53)
NAT (Network Address
Translation)
Any time an IP address is changed from one source IP or destination IP address to another address, network address translation can be said to have taken place. In general, half NAT is when the destination IP or source IP address is changed from one address to another.
Full NAT is when both addresses are changed from one address to another. No NAT is when neither source nor destination IP addresses are translated.
Preemption In VRRP, preemption will cause a Virtual Router that has a lower priority to go into backup should a peer Virtual Router start advertising with a higher priority.
Priority In VRRP, the value given to a Virtual Router to determine its ranking with its peer(s). Minimum value is 1 and maximum value is 254. Default is 100. A higher number will win out for master designation.
Proto (Protocol) The protocol of a frame. Can be any value represented by a 8-bit value in the IP header adherent to the IP specification (for example, TCP, UDP, OSPF, ICMP, and so on.)
SIP (Source IP Address) The source IP address of a frame.
SPort (Source Port)
Tracking
VIR (Virtual Interface
Router)
The source port (application socket: for example, HTTP-80/HTTPS-443/DNS-53).
In VRRP, a method to increase the priority of a virtual router and thus master designation
(with preemption enabled). Tracking can be very valuable in an active/active configuration.
You can track the following:
ifs: Active IP interfaces on the Web switch (increments priority by 2 for each)
ports: Active ports on the same VLAN (increments priority by 2 for each) vrs: Number of virtual routers in master mode on the switch
A VRRP address that is an IP interface address shared between two or more virtual routers.
42C4911, January 2007 255
Alteon OS Application Guide
Virtual Router
VRID (Virtual Router
Identifier)
VRRP (Virtual Router
Redundancy Protocol)
A shared address between two devices utilizing VRRP, as defined in RFC 2338. One virtual router is associated with an IP interface. This is one of the IP interfaces that the switch is assigned. All IP interfaces on the GbE Switch Modules must be in a VLAN. If there is more than one VLAN defined on the Web switch, then the VRRP broadcasts will only be sent out on the VLAN of which the associated IP interface is a member.
In VRRP, a value between 1 and 255 that is used by each virtual router to create its MAC address and identify its peer for which it is sharing this VRRP address. The VRRP MAC address as defined in the RFC is 00-00-5E-00-01-{VRID}. If you have a VRRP address that two switches are sharing, then the VRID number needs to be identical on both switches so each virtual router on each switch knows whom to share with.
A protocol that acts very similarly to Cisco's proprietary HSRP address sharing protocol.
The reason for both of these protocols is so devices have a next hop or default gateway that is always available. Two or more devices sharing an IP interface are either advertising or listening for advertisements. These advertisements are sent via a broadcast message to an address such as 224.0.0.18.
With VRRP, one switch is considered the master and the other the backup. The master is always advertising via the broadcasts. The backup switch is always listening for the broadcasts. Should the master stop advertising, the backup will take over ownership of the
VRRP IP and MAC addresses as defined by the specification. The switch announces this change in ownership to the devices around it by way of a Gratuitous ARP, and advertisements. If the backup switch didn't do the Gratuitous ARP the Layer 2 devices attached to the switch would not know that the MAC address had moved in the network. For a more detailed description, refer to RFC 2338.
256 Glossary 42C4911, January 2007
Index
Symbols
........................................................................ 161
[ ] ....................................................................... 18
Numerics
802.1Q VLAN tagging ......................................... 80
A accessing the switch
LDAP ......................................................... 53
RADIUS authentication ................................. 44 security ........................................................ 43 using the Browser-based Interface ................... 33 active-active redundancy .................................... 228 administrator account ........................................... 47 aggregating routes ............................................. 178 example ..................................................... 185 application ports ................................................ 127 authenticating, in OSPF ..................................... 199 autonomous systems (AS) .................................. 192
B
BBI
See Browser-Based Interface ........................ 193
Border Gateway Protocol (BGP) ......................... 171 attributes .................................................... 180 failover configuration .................................. 182 route aggregation ........................................ 178 route maps ................................................. 174 selecting route paths .................................... 181
Bridge Protocol Data Unit (BPDU) ..................... 107 broadcast domains ....................................... 75, 150
Browser-Based Interface .................................... 193
C
Cisco EtherChannel ....................................... 96, 99
CIST ................................................................ 121
Class of Service queue ....................................... 140 command conventions .......................................... 18
Command Line Interface .................................... 193 configuration rules port mirroring ............................................... 96 spanning tree ................................................ 96
Trunking ...................................................... 96
VLANs ........................................................ 96 configuring
BGP failover .............................................. 182
IP routing ................................................... 148
OSPF ......................................................... 204 port trunking ................................................. 98 spanning tree groups .................................... 113
D default gateway ................................................. 147 configuration example ................................. 149 default password .................................................. 47 default route
OSPF ......................................................... 197
Differentiated Services Code Point (DSCP) .......... 134
E
End user access control configuring ................................................... 61
EtherChannel ...................................................... 94 as used with port trunking ........................ 96, 99
Extensible Authentication Protocol over LAN (EAPoL)
68 external routing ......................................... 172, 192
42C4911, January 2007 257
Alteon OS Application Guide
F
Failover .............................................................218
failover overview ....................................................227
fault tolerance port trunking .................................................95
fragmenting jumbo frames ..........................144, 147 frame tagging. See VLANs tagging.
G gateway. See default gateway.
H high-availability .................................................217
Host routes
OSPF .........................................................202
hot-standby redundancy ......................................229
HP-OpenView .....................................................36
I
IBM Director .......................................................36
ICMP ................................................................126
IEEE standards
802.1d
........................................................106
802.1s
................................................117, 121
802.1x
..........................................................68
IGMP ........................................................126, 161
IGMP Relay ......................................................165
IGMP Snooping .................................................162
incoming route maps ..........................................175
internal routing ..........................................172, 192
Internet Group Management Protocol (IGMP) ......161
IP address routing example ...........................................148
IP interfaces example configuration ..........................148, 151
IP routing cross-subnet example .................................. 145 default gateway configuration ....................... 149
IP interface configuration ..................... 148, 151
IP subnets .................................................. 145 network diagram ......................................... 145 subnet configuration example ....................... 148 switch-based topology ................................. 146
IP subnets ......................................................... 146 routing ............................................... 145, 146
VLANs ........................................................ 75
ISL Trunking ...................................................... 94
J jumbo frames fragmenting to normal size ................... 144, 147 routing ............................................... 144, 147
L
LACP ............................................................... 101
LDAP authentication ............................................... 53
Link Aggregation Control Protocol ..................... 101 logical segment. See IP subnets.
LSAs ................................................................ 191
M management module ............................................ 24 manual style conventions ..................................... 18 meter ................................................................ 131 mirroring ports .................................................. 246 monitoring ports ................................................ 246
MSTP ............................................................... 121 multi-links between switches using port trunking ........................................ 93 multiple spanning tree groups ............................. 111
Multiple Spanning Tree Protocol ......................... 121
N network management ........................................... 36
258 Index 42C4911, January 2007
O
OSPF area types ................................................... 188 authentication ............................................. 199 configuration examples ........................205 to ??
default route ............................................... 197 external routes ............................................ 203 filtering criteria ........................................... 126 host routes ................................................. 202 link state database ....................................... 191 neighbors ................................................... 191 overview .................................................... 188 redistributing routes ............................ 174, 179 route maps ......................................... 174, 176 route summarization .................................... 196 router ID .................................................... 199 virtual link ................................................. 198 outgoing route maps .......................................... 175
P password administrator account .................................... 47 default ......................................................... 47 user account ................................................. 47
Per Hop Behavior (PHB) .................................... 134 port mirroring ................................................... 246 configuration rules ........................................ 96
Port Trunking ...................................................... 95 port trunking ....................................................... 95 configuration example ................................... 97 description ................................................... 99
EtherChannel ............................................... 94 fault tolerance ............................................... 95 ports for services ................................................ 127 monitoring ................................................. 246 physical. See switch ports.
priority value (802.1p) ....................................... 139 protocol types ................................................... 126
PVID (port VLAN ID) ......................................... 77
PVLAN .............................................................. 87
42C4911, January 2007
Alteon OS Application Guide
R
RADIUS authentication ............................................... 44 port 1812 and 1645 ...................................... 127 port 1813 ................................................... 127
SSH/SCP ..................................................... 60
Rapid Spanning Tree Protocol ............................. 118
Rapid Spanning Tree Protocol (RSTP) ................. 118 redistributing routes ........................... 174, 179, 185 redundancy active-active ............................................... 228 hot-standby ................................................ 229 re-mark ............................................................. 131
RIP (Routing Information Protocol) advertisements ............................................ 156 distance vector protocol ............................... 155 hop count ................................................... 155 metric ........................................................ 155
TCP/IP route information ....................... 16, 155 version 1 .................................................... 155 route aggregation ....................................... 178, 185 route maps ........................................................ 174 configuring ................................................. 176 incoming and outgoing ................................ 175 route paths in BGP ............................................. 181
Router ID
OSPF ......................................................... 199 routers ...................................................... 146, 149 border ........................................................ 192 peer ........................................................... 192 port trunking ................................................. 94 switch-based routing topology ...................... 146 routes, advertising .............................................. 192 routing .............................................................. 172 internal and external .................................... 192
Routing Information Protocol. See RIP
RSA keys ............................................................ 59
RSTP ................................................................ 118
S
SecurID .............................................................. 60 security
LDAP authentication ..................................... 53 port mirroring ............................................. 246
RADIUS authentication ................................. 44
VLANs ........................................................ 75 segmentation. See IP subnets.
Index 259
Alteon OS Application Guide segments. See IP subnets.
service ports ......................................................127
SNMP .........................................................36, 193
HP-OpenView ..............................................36
spanning tree configuration rules .........................................96
Spanning-Tree Protocol multiple instances ........................................111
SSH
RSA host and server keys ...............................59
SSH/SCP configuring ...................................................56
statistical load distribution .....................................95
summarizing routes ............................................196
switch failover ...................................................227
switch ports VLANs membership ..........................79
T
TACACS+ ..........................................................48
tagging. See VLANs tagging.
TCP ..................................................................126
technical terms port VLAN identifier (PVID) ..........................80
tagged frame .................................................80
tagged member ..............................................80
untagged frame ..............................................80
untagged member ..........................................80
VLAN identifier (VID) ..................................80
text conventions ...................................................18
thash .................................................................100
Trunk Hash algorithm .........................................100
Trunking configuration rules .........................................96
typographic conventions .......................................18
U
UDP ................................................................. 126 jumbo frame traffic fragmentation ................. 147 user account ........................................................ 47
V virtual interface router (VIR) .............................. 224 virtual link, OSPF .............................................. 198
Virtual Local Area Networks. See VLANs.
virtual router
ID numbering ............................................. 231 virtual router group ............................................ 229
Virtual Router Redundancy Protocol tracking ..................................................... 230
VLANs broadcast domains ................................. 75, 150 configuration rules ........................................ 96 default PVID ................................................ 77 example showing multiple VLANs ................. 85
ID numbers .................................................. 77
IP interface configuration ............................. 151 multiple spanning trees ................................ 106 multiple VLANs ........................................... 80 port members ............................................... 79
PVID ........................................................... 77 routing ....................................................... 150 security ........................................................ 75
Spanning-Tree Protocol ............................... 106 tagging ............................................... 79 to 86 topologies .................................................... 84
VRRP (Virtual Router Redundancy Protocol) active-active redundancy .............................. 228 hot-standby redundancy ............................... 229 overview ............................................ 224, 230 virtual interface router ................................. 224 virtual router ID numbering .......................... 231 vrid ........................................................... 224
260 Index 42C4911, January 2007
Scarica
Pubblicità