864 HH

Fireplace

Featuring the

Burner

Tested and Listed by

OMNI-Test Laboratories, Inc.

Beaverton, Oregon

Report # 028-F-59b-5

ANSI Z21.88b-2003

Built-In Direct Vent Fireplace

Natural Gas or Propane

Residential or Mobile Home

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This appliance may be installed as an OEM installation in a manufactured (mobile) home and must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280.

This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the appliance.

Installation Manual

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

Copyright 2007, T.I. $10.00 100-01182_002 4070201

4800 Harbour Pointe Blvd. SW

Mukilteo, WA 98275

2 Introduction

Overview

This manual details the installation requirements for the 864 HH (Home Heater) fireplace. For operating and maintenance instructions, refer to the 864 HH Owner's Manual

(part # 100-01181).

Listing Details

This appliance was listed by OMNI-Test

Laboratories, Inc. to ANSI Z21.88 - report # 028-

F-59b-5. The listing label is attached to the appliance near the gas control valve. A copy is shown to the right.

IAS (ICBO) Approval

This appliance was listed by OMNI-Test

Laboratories, Inc. - IAS # TL130 (previously

ICBO).

Massachusetts Approval

This manual has been submitted to the

Massachusetts Board of State Examiners of

Plumbers and Gas Fitters

National Fireplace Institute

© Travis Industries 4070201 100-01182_002

Table of Contents

Introduction

Overview ................................................................. 2

Listing Details.......................................................... 2

Safety Precautions

Safety Precautions ................................................... 4

Features and Specifications

Features ................................................................. 6

Installation Options................................................... 6

Heating Specifications .............................................. 6

Dimensions ............................................................. 6

3

Installation (continued)

Hearth Requirements ............................................... 32

Facing Requirements ............................................... 33

Drywall Installation ................................................ 33

Facing Overview ................................................... 34

Optional Faceplates – Sizing Chart .......................... 34

Thin Facing Installation .......................................... 35

Thick Facing Installation......................................... 37

Thick Facing Installation with FPX Arched Faces........ 38

Mantel Requirements................................................ 40

Install Example - Build-Out (Dog-House) w Hor. Term. ... 41

Install Example - Build-In w Hor. Term. ........................ 42

Installation

Packing List............................................................. 7

Additional Items Required.......................................... 7

Installation Overview ................................................. 7

Recommended Installation Procedure ......................... 7

Massachusetts Requirements .................................... 8

Converting the Fireplace to Top Vent Configuration ....... 9

Fireplace Placement Requirements............................. 11

Clearances...........................................................11

Raised Fireplaces .................................................11

Min. Framing Dims. - Rear Vent Configuration...........12

Min. Framing Dims. - Top Vent Configuration ............13

Nailing Brackets ....................................................14

Corner Installations - Rear Vent Configuration ...........15

Corner Installations - Top Vent Configuration.............16

Gas Line Requirements............................................. 17

Fuel ....................................................................17

Gas Line Connection .............................................17

Gas Inlet Pressure ................................................17

Gas Line Location .................................................17

Electrical Connection (required) .................................. 19

Wall Switch or Thermostat Installation ......................... 20

Wiring Diagram (Millivolt System) ............................20

Wall Switch Installation...........................................20

Vent Requirements................................................... 21

Vent Clearances ...................................................21

Altitude Considerations ..........................................21

Approved Vent ......................................................22

Vent Installation ....................................................22

Approved Vent Configurations .................................... 23

Restrictor Position.................................................23

Exhaust Restrictor Adjustment ................................23

Intake Restrictor Adjustment...................................24

Diffuser Plate Adjustment.......................................25

Rear Vent Config. W Horizontal Term. (no vertical rise) . 26

Rear Vent Config. W Horizontal Term. (w vertical rise) ... 27

Rear Vent Configuration with Vertical Termination.......... 28

Top Vent Configuration with Horizontal Termination ........ 29

Top Vent Configuration with Vertical Termination ........... 30

Termination Requirements ......................................... 31

Finalizing the Installation

Steps for Finalizing the Installation ............................. 43

Starting the Pilot Flame ......................................... 43

Pilot Flame Inspection ........................................... 43

Air Shutter Adjustment........................................... 44

Glass Frame Removal and Installation........................ 45

Fireback and Grate Installation................................... 47

Log Set Installation .................................................. 48

LP Conversion Instructions ....................................... 52

Optional Equipment

Grill Installation........................................................ 55

Remote Control Receiver Installation (2 Options) ......... 56

Extra Room Power Heat Duct .................................... 57

Accent Light Installation (sku 94400100) ................... 64

Index

Index...................................................................... 68

© Travis Industries 4070201 100-01182_002

4 Safety Precautions

Safety Warnings:

Failure to follow all of the requirements may result in property damage, bodily injury, or even death.

This unit must be installed by a qualified installer to prevent the possibility of an explosion.

This appliance must be installed in accordance with all local codes, if any; if not, in U.S.A. follow ANSI

Z223.1 and NFPA 54(88).

In Manufactured or Mobile Homes must confirm with: In USA, Manufactured Home Construction and

Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for

Manufactured Home Installations, ANSI/NCSBCS A225.1. This appliance may be installed in

Manufactured Housing only after the home is site located.

All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from outside the living-area structure.

Notify your insurance company before hooking up this fireplace.

The room heater should be inspected before use and at least annually by a qualified service person.

More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.

The instructions in this manual must be strictly adhered to. Do not use makeshift methods or compromise in the installation. Improper installation will void the warranty and safety listing.

This heater is approved for use with natural gas (NG) or propane (LP). Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard. Direct questions about the type of fuel used to your dealer. Check the label and flame adjust knob on the gas control valve.

Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area.

If the flame becomes sooty, dark orange in color, or extremely tall, do not operate the heater. Call your dealer and arrange for proper servicing.

It is imperative that control compartments, screens, or circulating air passageways of the heater be kept clean and free of obstructions. These areas provide the air necessary for safe operation.

Do not operate the heater if it is not operating properly in any fashion or if you are uncertain. Call your dealer for a full explanation of your heater and what to expect.

Do not store or use gasoline or other flammable liquids in the vicinity of this heater.

Do not operate if any portion of the heater was submerged in water or if any corrosion occurs.

Do not place clothing or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it.

Light the heater using the built-in piezo igniter. Do not use matches or any other external device to light your heater.

Never remove, replace, modify or substitute any part of the heater unless instructions are given in this manual. All other work must be done by a trained technician. Don't modify or replace orifices.

The viewing glass should be opened only for lighting the pilot or conducting service.

Any safety screen or guard removed for servicing must be replaced prior to operating the heater.

Travis Industries 4070201 100-01182_002

Safety Precautions

Safety Warnings (continued):

Allow the heater to cool before carrying out any maintenance or cleaning.

Operate the heater according to the instructions included in this manual.

If the main burners do not start correctly turn the gas off at the gas control valve and call your dealer for service.

The pilot flame must contact the thermopile and thermocouple. If it does not, turn the gas control valve to "OFF" and call your dealer.

This unit is not for use with solid fuel.

Do not place anything inside the firebox (except the included logs).

If the fiber logs become damaged, replace with Travis Industries log set.

Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.

Do not touch the hot surfaces of the heater. Educate all children of the danger of a high-temperature heater. Young children should be supervised when they are in the same room as the heater.

Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies.

Instruct everyone in the house how to shut gas off to the appliance and at the gas main shutoff valve.

The gas main shutoff valve is usually next to the gas meter or propane tank and requires a wrench to shut off.

Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility of any consequential damage(s).

5

© Travis Industries 4070201 100-01182_002

6 Features and Specifications

Installation Options

Residential or Mobile Home

Straight or Corner Placement

Flush or Recessed Face

Raised or Floor Placement

Internal or External Chase

Horizontal or Vertical Vent

Bedroom Approved

Heating Specifications

*

**

Natural Gas Propane

Approximate Heating Capacity (in square feet)*

Maximum BTU Input Per Hour

Steady State Efficiency** (with blowers on)

1,200 to 2,250

40,000

Up to 80 %

1,200 to 2,250

39,000

Up to 81 %

Heating capacity will vary with floor plan, insulation, and outside temperature.

Efficiency rating is a product thermal efficiency rating determined under continuous operation independent of installed system.

Dimensions

Optional "Extra Room Top Vent Configuration

29-1/4"*

19-3/4"*

8" Diameter Vent

38-1/4"

Power Heat Duct"

Connection

1-1/2"

AAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

1"

38-3/8"

36-3/4"

AAAAAAAAAAA

AAAAAAAAAAA

AAAAAAAAAA

* Includes the required 1/2" clearance.

Weight: 225 Lbs.

Rear Vent Configuration

8" Diameter Vent

Back of Fireplace

30-3/4"

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

7

Packing List

Propane Conversion Kit

Log Set (9 piece)

Grate

Wall Switch with Wire (see page 20 for details)

• Firestop (sku 93006094)

Additional Items Required

FIREBACKS ARE REQUIRED – See page 47.

(sku 98500662, 98500663, 98500664, or 98500665)

Direct Vent

Gas Line Equipment (shutoff valve, pipe, etc.)

Electrical Equipment (min. 14 gauge, grounded line)

Grill

Installation Overview

All requirements below must be met.

Top Vent

Configuration

See the section

See the section

"Vent Requirements"

"Mantel Requirements"

See "Facing

Side

Wall

AA

AA

AA

1" Min.

AAA

AA

AA

AA

AAAAAAA

Drywall AAAAAAA

AAAAAAA

AA

AA

AA

AA

AAA

AAA AAA

AAAAAAA

Drywall AA

AA

AA

AA

AA

AAA

AAA

AAA

AAA

AAAAAAA

AAA

AAA

AAA

See "Optional Non-

Requirements"

Combustible Hearth"

See the section

"Approved Vent

Configurations"

Insulation must not fill the 1/2" clearance around the back and sides of the fireplace.

Nailing Brackets

See the section "Minimum

Framing Dimensions"

See the section

See the section

"Gas Line Installation"

"Electrical Connection"

Rear Vent

Configuration

Required Travis

Firestop (sku

93006094)

AAAAAA

AAAAAA

AAAAAA

AAAAAA

Recommended Installation Procedure

Frame the opening for the fireplace. Make sure to allow for vent installation.

This fireplace is designed to accommodate 1/2" or 5/8" drywall (see "Nailing Brackets" on page 14 for details). Secure the fireplace to the framing.

Install the vent, gas line and electrical hook-up.

Install the wall switch (see page 20) or thermostat (if applicable).

Install the drywall.

Install the hearth (if applicable).

Install the facing (if applicable).

Install the mantel (if applicable).

Finalize the installation (see page 43) and install the grill or face.

© Travis Industries 4070201 100-01182_002

8 Installation

(for qualified installers only)

Massachusetts Requirements

Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be

ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight

(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP

CLEAR OF ALL OBSTRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

• The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

• Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

-- Detailed instructions for the installation of the venting system design or the venting system components; and

-- A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

-- The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

-- The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See “ Gas Line Requirements ” on page17 for additional Massachusetts requirements.

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

Top Vent or Rear Vent Configuration

This appliance is shipped in the rear vent configuration. To change to the top vent configuration, follow the directions below.

NOTE: the vent configuration affects several aspects of installation (framing, maximum vent rise, maximum vent run). When reviewing the installation requirements make sure to pay attention to the type of configuration being used.

9

Converting the

Fireplace to Top Vent

Configuration

Remove the 4 screws securing the cover plate.

Remove it and place it aside.

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAA

Top of Fireplace

Remove the 4 screws securing the cover plate (with hole).

This part may be discarded.

Back of Fireplace

Remove the 4 screws securing the intake cover plate. Remove it and place it aside.

AAAAAAAAA

AAAAAAAAA

AAAAAAAAA

AAAAAAAAA

AAAAAAAAA

AAAAAAAAA

AAAAAAAAA

Remove and discard all of the insulation found near the flue assembly (make sure to remove every piece).

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAAAAAAA

AAAAA

AAAAA

AAAAA

AAAAA

© Travis Industries 4070201 100-01182_002

10

Converting the

Fireplace to Top Vent

(continued)

Installation

(for qualified installers only)

NOTE: Use a magnetictipped nutdriver on these screws - take care to prevent the screws from falling into the fireplace.

Remove the 12 screws securing the flue assembly.

Rotate the flue assembly so the flue points upwards. Secure using the twelve screws removed earlier.

DO NOT OVER-

TIGHTEN THE

SCREWS.

Attach the intake cover plate with the screws removed earlier.

Travis Industries 4070201

Attach the cover plate with the screws removed earlier.

NOTE: flatten the four legs before insaling the cover plate.

100-01182_002

Installation

(for qualified installers only)

Fireplace Placement Requirements

The fireplace requires a 1/2" clearance from the angled sides and back of the fireplace to the framing members. No material (insulation, framing, etc.) may be placed into this area.

Fireplace must be installed on a level surface capable of supporting the fireplace and vent

Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)

This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance produces when determining a location.

Clearances

When installed, walls in front of the fireplace must be a minimum 1" to the side of the fireplace.

Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies.

Fireplace must be placed so the vents below and above the glass do not become blocked.

Raised Fireplaces

The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace (225 Lbs.) and vent.

11

Min. 49”

Fireplace

Enclosure

Height

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAA

AAAAAAAA

Optional Raised Hearth

(see “Hearth Requirements” for details)

AAAAA

AAAAA

AAAAAAA

AAAAA

AAAAA

AAA

AAA

© Travis Industries 4070201 100-01182_002

12 Installation

(for qualified installers only)

Minimum Framing Dimensions - Rear Vent Configuration

Included Firestop (required)

Part # 93006094

HINT: place the fireplace so the center line is at least 5" from both vertical framing members at the rear (this allows the vent to pass through the framing without modfications)

Minimum 49” Fireplace

Enclosure Height

Vent Clearances (8" dia. Vent):

1" to the sides, 1" below, and 3" above the vent to combustibles.

AAAAA

AA

AA

A

AAAAA

AAAAA

A

A

Center of Rear Vent

30-3/4"

Route the electrical line to a position to the left rear of the fireplace.

38-1/2"

25-3/4"

41-1/4"

20"

The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace.

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

Minimum Framing Dimensions - Top Vent Configuration

13

Minimum 49” Fireplace

Enclosure Height

Route the electrical line to a position to the left rear of the fireplace.

38-1/2"

41-1/4"

20"

The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace.

© Travis Industries 4070201 100-01182_002

14

Nailing Brackets

Installation

(for qualified installers only)

There are four nailing brackets on the front of the fireplace.

Follow the directions below to prepare the nailing brackets.

Once in place, nail or screw the nailing brackets to the framing.

NOTE: Additional nailing brackets are provided along the base of the fireplace.

Use these brackets if not using the front brackets.

WARNING: Make sure the fireplace is square and plumb when placed in the framing. Measured corner-to-corner, the fireplace should be square

(approx. 54-7/8” for each dimension). Use shims to insure the fireplace is square.

1/2” Drywall

For installations using

1/2” facing fold the larger tab out 90° (use a screwdriver if necessary).

5/8” Drywall

For installations using

5/8” drywall fold the shorter tab out 90° (use a screwdriver if necessary).

Travis Industries 4070201

TOP VIEW

Framing

Fireplace

Nailing Bracket

Drywall

AAAAAAA

AAAAAAA

TOP VIEW

Framing

Fireplace

Nailing Bracket

Drywall

AAAAAAA

AAAAAAA

100-01182_002

Installation

(for qualified installers only)

Corner Installations - Rear Vent Configuration

A typical 45° installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply).

Minimum 1" Clearance

Travis Firestop

(sku 93006094)

Minimum 1/2" Clearance

15

7-1/2" Approximate

(varies due to vent installation)

NOTE: Most installations use:

6" Section for 2x6 Walls

4" Section for 2x4 Walls

(Travis # 98900166)

48" Min.

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

A

A

A

A

A

A

A

A

A

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

© Travis Industries 4070201 100-01182_002

16 Installation

(for qualified installers only)

Corner Installations - Top Vent Configuration

A typical 45° installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply).

Minimum 1/2" Clearance

48" Min.

15-1/2"

AAAAAAAAAAAA

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

AA

AA

AA

AA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

17

Gas Line Requirements

MASSACHUSETTS INSTALLATIONS - WARNING:

THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN

THE COMMONWEALTH OF MASSACHUSETTS.

OTHER MASSACHUSETTS CODE REQUIREMENTS:

Flexible connector must not be longer than 36 inches.

Shutoff valve must be a “T” handle gas cock.

Only direct vent sealed combustion products are approved for bedrooms or bathrooms.

Fireplace dampers must be removed or welded in the open position prior to the installation of a fireplace insert or gas log.

A carbon monoxide (CO) detector is required in the same room as the appliance.

The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI

223.1 and the requirements listed below.

The fireplace and gas control valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig. For pressures under 1/2 psig, isolate the gas supply piping by closing the manual shutoff valve.

Leak test all gas line joints and the gas control valve prior to and after starting the fireplace.

Fuel

This fireplace is designed either for natural gas or for propane (but not for both). Check the sticker on the top of the gas control valve to make sure the correct fuel is used.

Gas Line Connection

Installation must be performed by a qualified installer, service agency or the gas supplier (In Massachusetts a licensed plumber/gasfitter).

Gas Inlet Pressure

Standard Input Pressure Minimum Input Pressure Maximum Input Pressure

Natural Gas 7" W.C. (1.74 kPA)3.5" W.C. (0.87 kPA)13.85" W.C. (3.45 kPA)

Propane 13" W.C. (2.73 kPA)8" W.C. (1.99 kPA) 14" W.C. (3.48 kPA)

If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is adequately adjusted, and the total gas load for the residence does not exceed the amount supplied.

The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the regulator is at an improper pressure.

© Travis Industries 4070201 100-01182_002

18 Installation

(for qualified installers only)

Gas Line Location

Left Side Gas Inlet (preferred)

A 2" high by 3" wide opening is located behind the gas inlet cover plate (it is 2" above the base of the fireplace).

The Gas Inlet is

3/8" FPT

A 12" flex tube and shutoff valve is included with the fireplace. The shutoff valve accepts a

1/2"MPT.

6-3/4"

You may remove this cover plate to install the gas line. The cover plate has a 7/8" diameter hole (covered with a push plug). By rotating the plate 180° the hole may be re-located. You may also secure the plate in a customized location using the self-drilling screws.

Right Side Gas Inlet

The Gas Inlet is

3/8" FPT

18"

A 2" high by 3" wide opening is located behind the gas inlet cover plate (it is 1-3/8" above the base of the fireplace).

6-1/4"

A 12" flex tube and shutoff valve is included with the fireplace. The shutoff valve accepts a 1/2"MPT.

You may remove this cover plate to install the gas line. The cover plate has a 7/8" diameter hole (covered with a push plug) in line with the gas inlet on the gas control valve. By rotating the plate 180° the hole may be re-located. You may also secure the plate in a customized location using the selfdrilling screws.

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

19

Electrical Connection (required)

The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified installer and must meet all local codes.

Make sure the household breaker is shut off prior to working on any electrical lines.

The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)

The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)

Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Left Side of Fireplace

Junction Box Assembly

Grounded 110V

Power Supply

Grounded Receptacle

Strain Relief

Receptacle Cover Plate

© Travis Industries 4070201 100-01182_002

20 Installation

(for qualified installers only)

Wall Switch or Thermostat Installation

Wiring Diagram (Millivolt System)

Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace. The switch must be installed by a qualified installer.

The included wall switch may be installed following the directions below. An optional thermostat may also be installed. It is attached to the gas control valve in the same manner.

Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Thermocouple Thermopile Piezo Igniter

On/Off Switch (on fireplace)

Red

Brown

Copper Co-Axial

Wire

A

Orange

Red

White

Spark Electrode

Pilot Hood

Optional Wall Switch,

Thermostat, or

Remote Control

Wall Switch Installation

1. Attach the included wire to the gas control valve.

Attach the two wires to the top and bottom posts on the gas control valve (orientation does not matter).

2. Determine a location for the wall switch (the wire is a maximum 25' long). Route the wire through the gas inlet hole (either side) to the junction box and attach following the directions below. Set the on/off switch on the appliance to "OFF" to control the appliance with the wall switch.

a

Insert the wire through the back of the mounted junction box (your junction box may look different).

Expose 1/2" of each wire. Secure the wires to the posts on the side of the on/off switch

(orientation does not matter).

From

Appliance

Standard

Screwdriver b

Carefully pack the wires into the junction box. Attach the switch to the junction box. Attach the switchplate to the switch.

Standard

Screwdriver

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

Vent Requirements

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use it's own separate vent system.

In addition to the requirements listed here, follow the requirements provided with the vent.

A firestop is required whenever the vent penetrates a wall, floor, or ceiling (passes through framing members). Horizontal vent less than 48" above the fireplace must use the Travis

Firestop (sku 93006094 - it incorporates a 3" clearance above, 1" clearance below and to the sides of the vent). Other penetrations only require a 1" clearance and may use a standard firestop (make sure the required 1" clearance is met).

Always use the high-wind termination (if available from the vent manufacturer).

21

Vent Clearances

The vent must maintain the required clearance to combustible materials to prevent a fire. Do not fill air spaces with insulation.

Sides

Above

Below Horizontal or 45° Section

Before 48" Rise

1"

3"

1"

After 48" Rise

1"

1"

1"

Vertical Termination

Required Firestop

Horizontal

Termination

Use a roof flashing and storm collar whenever passing through the roof

Use a firestop whenever passing through a ceiling

Use a support box on exposed vent

Min. 1"

Min. 1"

Min. 3"

(1" if a minimum 48" above the fireplace)

Min. 1"

Altitude Considerations

This heater has been tested at altitudes ranging from sea level to 6,000 feet. In this testing we have found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.

Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard.

Consult your dealer or installer if you suspect an improperly adjusted air shutter.

© Travis Industries 4070201 100-01182_002

22 Installation

(for qualified installers only)

Approved Vent

Rear vent configurations use 8" diameter Simpson Dura-Vent Model GS vent.

Top vent configurations use 8" or 6-5/8" diameter Simpson Dura-Vent Model GS vent. If using

6-5/8" diameter vent, attach the 8" to 6-5/8" reducer (Travis part # 98900165) to the fireplace.

6-5/8" Diameter Vent

Reducer - # 98900165

Vent Installation

Slide the vent sections together and turn 1/4 turn until the sections lock in place.

Screws are not required to secure the vent. However, three screws may be used to secure vent sections together if desired.

High temperature sealant is recommended at the appliance starter section connection (use high-temperature silicone or Mill-Pac®).

If disassembly is required, at time of re-assembly check to see if the vent creates a tight fit. If it does not, apply high temperature sealant to the joints of the affected sections.

Horizontal sections require a 1/4" rise every 12" of travel

Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

Approved Vent Configurations

Restrictor Position

Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor positions. The charts for acceptable vent configurations detail the correct vent restrictor positions.

Exhaust Restrictor Adjustment

23

If the diffuser is required to be in position # 2, you may wish to adjust the diffuser while the exhaust restrictor is removed.

Firebox Roof

Back Wall of Firebox

Loosen these four screws on the exhaust restrictor.

(closed) #6

# 5

# 4

# 3

# 2

(open - stock position) # 1

Slide the restrictor to the correct restrictor position (see the illustration below). The rear screws indicate restrictor position. In this example, the restrictor is set in position # 3. Tighten the screws to secure the restrictor.

NOTE: If using position 4, 5, or 6, you will need to remove the forward screws. These screws are then reinserted into the back holes exposed while sliding the restrictor.

Back of Firebox

© Travis Industries 4060907 100-01182

24 Installation

(for qualified installers only)

Intake Restrictor Adjustment

The intake restrictor is shipped in position # 1 (open). To adjust the restrictor to postion # 2 (closed, follow the instructions below.

NOTE: The intake restrictor is accessed with the burner removed (see page 52).

Loosen these two screws.

A

A

AA

This restrictor is in position # 1.

Slide the intake restrictor down and re-tighten the screws to secure.

A

A

AA

This restrictor is in position # 2.

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

Diffuser Plate Adjustment

Certain vent configurations require the diffuser plate to be adjusted (refer to the approved vent configuration charts for details). Position # 1 is stock (bent). Position # 2 is flattened. See the directions below to change the diffuser to position #2.

Firebox Roof

25

Back Wall of Firebox

Remove the exhaust restrictor.

1/4" Nutdriver

1/4" Nutdriver

Remove the diffuser.

DIFFUSER SIDE VIEW

Before (Stock - Position # 1)

Bend the round portion of the diffuser so it is flat (position # 2).

After (Position # 2)

Secure the flattened diffuser plate with the screws removed earlier.

© Travis Industries 4070201

Replace the exhaust restrictor (see “Exhaust

Restrictor Adjustment” for restrictor settings).

100-01182_002

26 Installation

(for qualified installers only)

Rear Vent Configuration with Horizontal Termination (no vertical rise)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and diffuser positions.

HINT: Travis Industries provides a minimum rear vent kit (sku 98900168). It includes a 4” section and a horiztontal termination cap.

Vent with No 45° Elbow

3 feet • Exhaust Restrictor Removed

• Intake Restrictor # 1 (stock)

• Diffuser Position # 1 (stock)

0 feet

• Min. 4" Horizontal Section

• Max.48" Horizontal Section(s)

Vent with 1 45° Elbow

3 feet

0 feet

• Exhaust Restrictor Removed

• Intake Restrictor # 1 (stock)

• Diffuser Position # 1 (stock)

See the charts above to determine maximum vent

Optional 45° Elbow

Termination

• Min. 4" Horizontal Section

• Max. 24" Horizontal Section(s)

EXHAUST RESTRICTOR REMOVAL

Back Wall of

Firebox

Travis Industries 4060907

If venting to the rear with no vertical rise, remove and discard the exhaust restrictor.

Replace the screws in the same holes.

100-01182

Installation

(for qualified installers only)

Rear Vent Configuration with Horizontal Termination (with vertical rise)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and diffuser positions.

Up to four elbows (45° or 90°) may be used.

Only one horizontal elbow may be used.

27

22' (max)

20 feet

15 feet

10 feet

5 feet

0 feet

22' (max)

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

Intake Restrictor # 2 AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

Diffuser Position # 1 (stock) AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

20 feet

15 feet

10 feet

5 feet

0 feet

© Travis Industries

H2

This is considered a horizontal elbow (it does not matter whether it turns right or left).

It may be a 90° or 45° elbow.

H1

4070201

Horizontal length is calculated by adding both lengths of horizontal run

(Horizontal Length = H1 + H2).

This is considered a vertical elbow

100-01182_002

28 Installation

(for qualified installers only)

Rear Vent Configuration with Vertical Termination

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and diffuser positions.

Up to four elbows (45° or

90°) may be used.

Only one horizontal elbow may be used.

40' (max)

35 feet

30 feet

25 feet

20 feet

15 feet

10 feet

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

Exhaust Restrictor # 5 AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

40' (max)

35 feet

30 feet

25 feet

20 feet

15 feet

10 feet

5 feet 5 feet

0 feet 0 feet

Travis Industries

This is considered a horizontal elbow (it does not matter whether it turns right or left).

It may be a 90° or 45° elbow.

H2

H1

4070201

Horizontal length is calculated by adding both lengths of horizontal run

(Horizontal Length = H1 + H2).

This is considered a vertical elbow

100-01182_002

Installation

(for qualified installers only)

Top Vent Configuration with Horizontal Termination

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and diffuser positions.

Up to four elbows (45° or 90°) may be used.

May use 8" or 6-5/8" diameter vent (see page for 21 details).

Only one horizontal elbow may be used.

29

21' (max)

20 feet

15 feet

10 feet

5 feet

0 feet

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

21' (max)

20 feet

15 feet

10 feet

5 feet

0 feet

© Travis Industries

H2

This is considered a horizontal elbow (it does not matter whether it turns right or left).

It may be a 90° or 45° elbow.

H1

4070201

Horizontal length is calculated by adding both lengths of horizontal run

(Horizontal Length = H1 + H2).

This is considered a vertical elbow

100-01182_002

30 Installation

(for qualified installers only)

Top Vent Configuration with Vertical Termination

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and diffuser positions.

Up to four elbows (45° or

90°) may be used.

Only one horizontal elbow may be used.

May use 8" or 6-5/8" diameter vent (see page for

21 details).

40' (max)

35 feet

30 feet

25 feet

20 feet

15 feet

10 feet

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

40' (max)

35 feet

30 feet

25 feet

20 feet

15 feet

10 feet

5 feet 5 feet

0 feet 0 feet

Travis Industries

H2

This is considered a horizontal elbow (it does not matter whether it turns right or left).

It may be a 90° or 45° elbow.

H1

4070201

Horizontal length is calculated by adding both lengths of horizontal run

(Horizontal Length = H1 + H2).

This is considered a vertical elbow

100-01182_002

Installation

(for qualified installers only)

31

Termination Requirements

K

L

M

N

I

J

C

D

A

B

E

NOTE: Measure all clearances from the nearest edge of the exhaust hood.

F

G

H

Minimum 9" clearance from any door or window

Minimum 12" above any grade, veranda, porch, deck or balcony

Minimum 3-3/8" from outside corner walls

Minimum 0" from inside corner walls

Minimum 11" clearance below unventilated soffits or roof surfaces

Minimum 18" clearance below ventilated soffits

Minimum 6" clearance below roof eaves

NOTE: Vinyl surfaces require 24"

Roof

Surface

11” Min.

6” Min.

Roof

Eaves

Minimum 18" clearance below a veranda, porch, deck or balcony (must have two open sides)

Minimum 48" clearance from any adjacent building

Minimum 84" clearance above any grade when adjacent to public walkways or driveways

NOTE: may not be used over a walkway or driveway shared by an adjacent building

Minimum 48" clearance from any mechanical air supply inlet

Minimum 36" clearance above and 48” below and to the sides of non-mechanical air supply inlet

Minimum 36" from the area above the meter/regulator (vent outlet)

Minimum 36" from the meter/regulator (vent outlet)

Minimum 24” above the roof line (for vertical terminations)

Minimum 24” horizontal clearance to any surface (such as an exterior wall) – for vertical terminations

E

N

M

E

E

A

K

J

A H

G

F

D

C

I

L

B

NOTE: Measure clearances to the nearest edge of the exhaust hood.

Use the vinyl siding standoff (#950) when installing on an exterior with vinyl siding.

Vent termination must not be located where it will become plugged by snow or other material.

Venting termination shall not be recessed into a wall or siding.

These clearances meet UMC-1994 code standards.

© Travis Industries 4070201 100-01182_002

32 Installation

(for qualified installers only)

Hearth Requirements

Do not build a hearth more than 1” above the baseplate

Floor Mounted

Fireplaces

(this area must remain clear

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAAA

AAAAAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAAAAAAAAAAAA

If installed near carpet or other combustible flooring, the fireplace must be raised so the base of the unit is above the carpet surface or

AAAAAAAAAAA

AAAAAAAAAAA

AAAAAAAAAAA

AAAAAAAAAAA

AAAAAAAAAAAAAAAAAA a hearth to protect the flooring surface from discoloration or other negative impact from the heater.

Raised

A hearth is not required

Fireplaces

when the fireplace is

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAA

AAAAAAAA

AAAAAAAAAAAAA

AA

AA

AA

AA

AA

A

A

AA

AAAAAAAA

AAAAAAAAAAAAA

AAAAAA

AAAAAA

AAAAAA

AAAAAA

AAAAAA

AA

AA

AA

AA

AA

AA

A

A

A

A raised above the flooring surface.

AAAAAAAAAAAAAA

AAAAAAAAAAAAAA

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

Facing Requirements

This appliance is designed to allow for drywall (or other combustible facing) to contact the sides and top of the front of the fireplace.

Non-combustible facing (tile, masonry, etc.) must be placed over the fiber board on the front of the fireplace (see "Facing Overview" on page 34 for further details).

Drywall Installation

33

Drywall Installation Drywall may be installed up to the front edge of the fireplace.

If the fireplace is raised, drywall up to the

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA bottom edge as well.

The non-combustible fiber board must remain in place above the fireplace. Noncombustible facing (tile, masonry, etc.) must be placed over the fiber board.

Do not install drywall (or any other combustible) in front of the fireplace.

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

Drywall

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

© Travis Industries

TOP VIEW

Framing

Fireplace

Nailing Bracket

Drywall

AAAAAAAA

4070201 100-01182_002

34

Facing Overview

Installation

(for qualified installers only)

Upgrade faces are available for this fireplace and may influence facing installation. Consult with your

Travis Dealer if you are using an upgrade face.

Optional non-combustible facing may be installed on the fireplace. Use the guidelines below to determine the location (also see the following pages for detailed diagrams.

Tile Line Any non-combustible facing under 1" thick (see "Thin Facing" on page 35).

Masonry Line Any non-combustible over 1" thick (see "Thick Facing" on page 37).

Hearth Line Non-combustible hearth/facing should be installed up to this location (1" above the base of the fireplace). The fireplace may be raised to accommodate thicker hearth materials.

Hearth Line

Masonry Line

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAA

AAAAAA

AAAAAA

AAAAAAAAAAAAAAAAAA

AAA

AAA

AAA

AAA

AAA

AAA

AAAAAAA

AAAAAAA

AAAAAAA

AAAAAAA

AAAAAAA

AAAAAAA

Tile Line

Hearth Line

NOTE: The hearth or facing can extend no greater than 1” above the base of the fireplace.

The fireplace may be raised to accommodate thicker hearth materials.

Optional Faceplates – Sizing Chart

Name Height Width Notes

FPX Artisan, Classic, Fr Ctry 35-3/4” 41”

Winthrop Victorian Lace 34-1/8” 36-7/8”

45-3/4” Radius – May fit over top of tile facing

Optional facing will butte to edge of faceplate (tile line)

Wilmington Hearthview

Winthrop Bungalow

35-3/4”

34”

41”

36-7/8”

May fit over top of tile facing

Optional facing will butte to edge of faceplate (tile line)

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

Thin Facing Installation (tile, marble, or other non-combustible under 1" thick)

35

Upgrade faces are available for this fireplace and may influence facing installation. Consult with your

Travis Dealer if you are using an upgrade face.

Do not install tile (or other material) in front of the glass frame, convection channel, or access panel openings. This area must remain open to access internal components and for convection air.

TOP VIEW

Framing

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAA

AAA

AAA

AAA

AAA

AAAAA

AAAAA

AAAAA

AAAAA

AAAAAAAAAAAAAAA

AAAAAAAAAAAAAAA

AAA

AAA

AAA

Raised Fireplaces:

Tile Line

Hearth Line fireplace. The fireplace may be raised to accommodate thicker hearth materials.

Facing is installed 1” (maximum)

Fireplace

AAAAAA

AAAAAA

© Travis Industries

Tile

2-7/8”

Nailing Bracket

Drywall

NOTE FOR FPX FACES:

7-7/8”

AAA

AAA

AAAA

AAAA above the base of the fireplace.

AAA

AAA

AAAA

FRONT VIEW

AAAAAAAAAAAAAAAA

AAAA

AAAA

AAAA

AAAA

AAAA

FPX arched faces require the FPX Face

Upgrade Kit (sku 98500686) and a triangular piece of facing in these upper corners. See the instructions included with the face for further details.

AAAA

AAAA

AAAA

AAAA

AAAA

AAAA

AAA

AAA

AAA

4070201

37”

Fiber Board (must remain in place)

2”

1-1/2”

1-1/8”

34-1/4”

1”

100-01182_002

36 Installation

(for qualified installers only)

Thin Facing Installation (tile, marble, under 1" thick) - Side View

Raised Fireplace

(with no Hearth)

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

A

A

AAA

AAA

AAA

AAA

AAA

AAA

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

AAA

A

AAA

AAA

A

A

A

A

A

A

A

A

AAA

AAA

A

A

A

A

AAA

AAA

1”

Drywall

Note how the facing extends 1” above the base of the fireplace.

Floor

Tile

(or other facing under 1” thick)

Face

Fireplace Support

Floor-Mounted Fireplace with Hearth

A

A

A

A

A

A

A

A

AAA

A

A

A

A

A

A

Drywall

Tile

(or other facing under 1” thick)

Face

A

A

A

A

Hearth (note how it extends under the face - max. 1” thick). The fireplace may be raised to accommodate thicker hearth materials.

AAA

Floor

Max. 1”

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

Thick Facing Installation (stone, brick, or other non-combustible over 1" thick)

37

If using a Fireplace Xtrordinair (FPX) arched face, see "Thick Facing with a Fireplace Xtrordinair Arched

Faces" on page 38.

Do not install masonry (or other material) in front of the fireplace. This area must remain open to install the face.

TOP VIEW - Protruding Masonry

Fireplace

Framing

Nailing Bracket

Drywall

Masonry Line

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAA

AAAA

AAA

AAA

AAAA

AAAA

AAA

AAA

AAA

AAA

AAA

AAAA

AAA

AAAA

AAA

AAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAA

Drywall

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAA

AAAA Hearth Line

AAAAAAAAAAAAAAAAAA

AAA

AAAA

AAAA

AAAA

AAA

AAA

AAAA

AAA

AAA

AAA

AAAA

AAAA

AAAAAAA

AAAAAAA

AAAAAAA

AAAAAAA

AAAAAAA

Floor-Mounted Fireplaces or Raised Hearths:

Build the hearth 1” (max.) above the base of the fireplace. The fireplace may be raised to accommodate thicker hearth materials.

Raised Fireplaces:

Masonry is installed 1” (maximum) above the base of the fireplace.

Fireplace

AAAAAAA

AAAAAAA

Masonry

TOP VIEW - Recessed Masonry

Framing

Drywall

(or cement board, etc.)

AAAAAAA

AAAAAAA

AAAAAAA

AAAAAAA

Masonry

NOTE: The nailing brackets are not used for this type of installation - secure the fireplace to the floor with the brackets along the base of the fireplace.

AAA

AAA

AAAA

AAA

AAA

AAAA

AA

AA

AAAA

AAAA

FRONT VIEW

41”

Fiber Board (must remain in place)

AAAAAAAAAAAAAAAAAAAAAAAA

AAAAA

AAAAA

A

A

AAAAA

AA

AAA

AAA

AAAA

AA

AAAA

AAAA

AAAA

AAA

AAAA

AAAAAA

AAAAAA

AAAAAA

AAAA

AAAA

AAAA

AAAA

1-1/2”

35-3/4”

1”

© Travis Industries 4070201 100-01182_002

38 Installation

(for qualified installers only)

Thick Facing with Fireplace Xtrordinair (FPX) Arched Faces

The following illustration shows facing considerations for those fireplaces utilizing FPX arched faces.

The facing must be non-combustible and over 1" in depth.

The Fireplace Xtrordinair 864

Masonry Template is recommended for masonry installation (sku 98500688). The template helps locate and support the masonry as it being installed.

Before installing masonry, install the FPX Face Upgrade Kit

(98500686). This covers the upper corners.

TOP VIEW

Fireplace

Face

AAAAAAAA

AAAAAAAA

Masonry

Travis Industries

Framing

Nailing Bracket

Drywall

AAAA

AAAA

AAAA

AA

AAA

AAA

AAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAA

AAA

AAA

AAA

AAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AA

AAAAA

AAAAA

AAAA

AAAA

AAAA

AAAA

AAA

AA

AAA

AAA

AAAAAAA

AAAAAAA

AAAAAAA

AAAAAAA

AAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

Hearth Line

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAA

AAAA

AAAA

AAAA

AAAA

AAA

AAAA

AAAA

AAAA

AAAA

Floor-Mounted Fireplaces or Raised Hearths:

Build the hearth 1” (max.) above the base of the fireplace. The fireplace may be raised to accommodate thicker hearth materials.

Raised Fireplaces:

Masonry is installed 1” (maximum) above the base of the fireplace.

AAAA

AAAA

AAAA

AAAA

AAA

AAA

AAAAAAAA

AAAAA

AAAAAA

AAAAAA

AAAAA

AA

AA

AAAA

AAA

AAAA

AAAA

AAAA

AAAA

AAAAA

Fiber Board (must remain in place)

AAA

FRONT VIEW

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAA

AAAAAAA

AAAAAAA

1-1/2”

5”

AAAA

AAAAA

AAA

AAA

AAAA

AAAA

AAA

AAA

AAAAA

AAAAA

AAAAA

AAAAA

AAAAAA

AAAAAA

AAAAAA

AAAAAA

41”

45-1/2” Radius

35-3/4”

1”

4070201 100-01182_002

Installation

(for qualified installers only)

39

Thick Facing Installation - Side View

Floor-Mounted Fireplace with Hearth

SIDE OF FIREPLACE

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

A

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

A

A

A

A A

A

A

A

A A

A

A

A

A

Face

Drywall

Masonry

(or other non-combustible over 1” thick)

Hearth (note how it extends under the face - max. 1” thick). The fireplace may be raised to accommodate thicker hearth materials.

A

A

AAA

Floor

Max. 1”

Raised Fireplace (with no Hearth)

SIDE OF FIREPLACE

AAA

AAA

AAA

AA

AA

AA

AA

AAA

AAA

AAA

AAA

AAA

AAA

AA

AA

AA

AA

AA

AA

AA

AA

A

A

A

A

A

A

A

A

A

A

A

AA

AA

AA

AA

AA

AA

AA

AA

A

A

A

AA

AA

AA

AA

AA

AA

AA

A

A

AA

AA A

AA

AA

AA

AA

A

A

A

A

AA

AA

AA

AA

AA

AA

AA

AA

A

A

A

A

A

1”

Drywall

Masonry

(or other non-combustible over 1” thick)

Face (Behind Masonry)

The masonry extends 1” above the base of the fireplace.

Fireplace Support

Floor

© Travis Industries 4070201 100-01182_002

40 Installation

(for qualified installers only)

Mantel Requirements

Use the table below to determine the maximum mantel depth allowed. The mantel depth

(measured from the face of the fireplace) must fall in the shaded portion of the table.

Any facing material that protrudes more than 3/4” from the face of the fireplace is considered a mantel and must meet the mantel requirements.

Mantel

Height

Above

Face (a)

18+”

17”

16”

15”

14”

13”

12”

11”

10”

9”

8”

3”

2”

1”

0”

7”

6”

5”

4”

Maximum Mantel Depth (b)

0” 1” 2” 3” 4” 5” 6” 7” 8” 9” 10” 11” 12”

36-3/4” a b

AAAAAAAAAAA

AAAAAAAAAAA

AAAAAAAAAAA

AAAAAAAAAAA

AAAAAAAAAAA

AAAAAAAAAAA

AAAAAAAAAAA

Combustible mantel columns (legs) that protrude more than 3/4” from the glass frame must meet the sidewall clearance (1”).

If they protrude 3/4” or less, they may be placed directly to the side (but not in front) of the fireplace.

Non-combustible mantel columns do not have a minimum clearance.

Examples: • If you wish to have a 8” deep mantel, it must be at least 12-1/4” above the fireplace face (49” above the base).

• If you wish to have a mantel 8” above the fireplace face, it must be no deeper than 3-3/4”.

Travis Industries 4070201 100-01182_002

Installation

(for qualified installers only)

41

Installation Example - Build-Out (Dog-House) with Horizontal Termination

The framing, facing, and other building materials depicted below are for example only. Refer to local building codes for framing, facing, and insulating requirements in your area.

AAAAAAAAAAAAAA

Side View

See “Vent Termination” for full requirements.

Horizontal Termination*

AAAAAAAAAAAAAA

A

A

A

A

AAAAAAAAAAAAAA

4” Section*

* Travis Ind. MIn. Vent Kit (SKU 98900168)

Includes a 4” section and horizontal termination.

NOTE FOR 2 x 4 EXTERIOR WALLS:

When installed with a 2x4 exterior wall, the

Firestop termination may not fit flush against the exterior wall. You may wish to place framing around the termination to fill the gap.

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AAA

AAA

A

AA

AA

A

A

A

A

A

AAA

A

A

A

AAA

A

A

A

A

AAA

Optional Tile

Top View

NOTE:

1/2” Clearance to sides and back of fireplace.

A

A

AA

AA

AA

AA

AAA

AA

AA

A

AA

AA

AA

AA

AA

AA

AAAAAA

A

Insulation

NOTE:

In colder climates the fireplace may require an insulated enclosure.

AA

AA

AA AA

AA

AA

AAA

AA

AA

A

AA

AA

NOTE: If required to use drywall inside the firebox enclosure, make sure to alter the framing accordingly.

Vapor

Barrier

AAA

AAA

AAA

AA

AAAAAAAA

Drywall

Optional Tile

© Travis Industries 4070201 100-01182_002

42 Installation

(for qualified installers only)

Installation Example - Build-In with Horizontal Termination

The framing, facing, and other building materials depicted below are for example only. Refer to local building codes for framing, facing, and insulating requirements in your area.

Side View

See “Vent Termination” for full requirements.

AAAAAAAAAAAAAA

AAA

AAA

AAA

AAA

AAAAAAAAAAAAAA

AAAAAAAAAAAAAA

AAAAAAAAAAAAAA

Horizontal Termination* termination may not fit flush against the exterior termination to fill the gap.

4” Section*

* Travis Ind. MIn. Vent Kit (SKU 98900168)

Includes a 4” section and horizontal termination.

NOTE FOR 2 x 4 EXTERIOR WALLS:

When installed with a 2x4 exterior wall, the

Firestop wall. You may wish to place framing around the

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

SIDE OF FIREPLACE

AA

AA

AA

AAA

AAA

A

AA

AAA

A

A

A

A

A

A

A

AAA

A

AAA

A

AAA

AAA

AAA

Drywall

A

A

A

AAA

AAA

AAA

AAA

AAA

AAA

A

A

A

Optional Tile

A

A

A

A

A

Top View

NOTE:

1/2” Clearance to sides and back of fireplace.

Insulation

Travis Industries

AA

A

A

A

A

A

A

A

A

A

AA

A

A

AA

AA

AA

A

A

AA

A

A

A

A

A

A

A

A

A

AAAAAAA AAAAAAA

AAA

NOTE: If required to use drywall inside the firebox enclosure, make sure to alter the framing accordingly.

Drywall

Optional Tile

4070201 100-01182_002

Finalizing the Installation

(for qualified installers only)

Steps for Finalizing the Installation

1. Remove the glass (see page 45).

NOTE: If using propane (LP) convert the appliance prior to installing the logs.

2. We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected once it enters the firebox, ensuring gas does not build up.

3. Install the logs (see page 47).

4. Turn on the gas to the fireplace. Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot.

43

Starting the Pilot Flame

WARNING: When lighting or re-lighting the pilot, the glass must be removed (see page 43).

a Remove the glass.

b Push the gas control knob in slightly and turn it to the "OFF" position. The knob will not turn from "ON" to "OFF" unless the knob is depressed slightly. Wait five minutes to let any gas that may have accumulated inside the firebox escape. If you smell leaking gas, follow the directions on the cover "IF YOU SMELL GAS".

c Turn the gas control knob to the "PILOT" position and press the knob in, this will allow gas to flow to the pilot light. Press the button on the pilot igniter repeatedly until you see the pilot light.

WARNING: If the pilot does not light after 15 seconds, release the knob and call your dealer for service. Do not attempt to light pilot until service has been performed.

NOTE:

You may wish to remove the log set to gain a better view of the pilot (see page 47).

d Keep the gas control knob depressed for 30 seconds once it is lit.

e Release the gas control knob. If the pilot goes out, repeat step C. If the pilot refuses to stay lit, call your dealer for service. With the pilot lit, proceed to step “f”.

f Replace the glass.

g Turn the gas control knob counter-clockwise to "ON". The pilot is now lit and the heater can be turned on and off.

5. Check the pilot flame following the directions below.

Pilot Flame Inspection

The pilot flame should look like the illustration below. Adjust the pilot flame if necessary.

To adjust the pilot flame, turn this screw. Clockwise lowers the flame while counter-clockwise raises it.

Standard

Screwdriver

The pilot flame must contact the thermocouple and thermopile (see the illustration below). Adjust the pilot up or down as necessary.

6. Replace the glass.

7. Start the main burner (the main burner circuit is detailed on page 20). Leak test all gas joints again.

© Travis Industries 4070201 100-01182_002

44 Finalizing the Installation

(for qualified installers only)

8. Check the air shutter following the directions below.

Air Shutter Adjustment

Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.

Correct Not Enough Air Too Much Air

Flames should be blue at the base, yellow-orange on the top.

Air Shutter Adjustment

If the flames are over 14" tall or sooty on the ends, open the air shutter.

If the flames are all blue and short, close the air shutter.

The air shutters may be adjusted while the burner is on (take care to prevent contacting the burner area).

There are two air shutters on this fireplace - adjust both air shutters to obtain the correct flame.

Rear Air

Shutter Control

Move the controls left or right until the flame looks correct. The rear air shutter affects the rear portion of the burner, the front air shutter the front portion of the burner.

Pushing to the left gives the flame less air, making it more orange. Pushing to the right gives the flame more air, making it more blue.

Front Air Shutter

Control

NOTE: If the air control is all the way open, yet the flames remain sooty, shut off gas to the fireplace and contact a qualified gas service technician.

LESS

AIR

MORE

AIR

NOTE: The logs must be installed correctly to monitor the flame while adjusting the air shutter.

9. Turn the flame adjust knob to its highest position - the flames should not contact the top of the firebox. Check the flame on low position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your Travis dealer for a remedy.

10. Give this manual to the home owner for future reference and fully explain operation of this heater. For comprehensive operating and maintenance instructions, refer to the Owner's

Manual (part # 100-01181).

ACID WASH WARNING: Before installing the faceplate, make sure any masonry that has been treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid wash (muriatic acid) is used to remove excess mortar. If not properly neutralized with an ammonia solution, the plated face may develop a permanent tarnish when the acid evaporates over time.

Contact your dealer if uncertain your facing has been properly neutralized.

Travis Industries 4070201 100-01182_002

Finalizing the Installation

(for qualified installers only)

Glass Frame Removal and Installation

Warning:

Warning:

The appliance must be completely cool before removing the glass.

Do not strike or slam the glass.

a

Based upon the face being used, either:

(a) swing the access door down and remove the top grill,

(b) remove the face (unscrew or lift off - see the instructions included with the face for details).

Open the six latches holding the glass frame in place

(start with the bottom three) - follow the directions shown to the right.

Top of

Firebox

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAAAAAA

AAAA

AAAA

AA

AAAA

AAAA

AAAA

AA

AA

AA

Latch

Glass

45

b

Lift the glass frame up and pull it forward to remove.

NOTE:

You may need to lift the glass frame while re-attaching.

Catch

(on glass frame)

Re-Attaching the Glass Frame: a) Hang the glass frame on the firebox.

b) While holding in place, attach the upper latches

(follow the instructions to the right in reverse).

c) Lift the glass frame slightly and attach the lower latches.

NOTE: Make sure the glass frame is all the way in place - it should be flush with the front of the fireplace when installed.

© Travis Industries 4070201 100-01182_002

46 Finalizing the Installation

(for qualified installers only)

Glass Frame Removal and Installation (continued)

The latch can come loose from the latch assembly. This occurs only when it is rotated. Follow the directions below to re-install the latch if it comes loose.

Hold the latch at an angle and insert it into the slot on the glass frame anchor.

Latch

Top of

Firebox

NOTE: this slot may be at a different angle than illustrated.

Glass Frame

Anchor

Note how the washer on the latch fits behind the flange on the glass frame anchor.

Once fully inserted, turn the latch until it is upright.

Travis Industries 4070201 100-01182_002

Finalizing the Installation

(for qualified installers only)

47

Fireback and Grate Installation

WARNING: Firebacks are required for this fireplace and must be installed prior to operation.

1 Remove the glass frame.

3 Remove the exhaust restrictor (see page 23). Make sure to return the restrictor to the correct position after the firebacks are in place.

4 Install the firebacks and grate following the directions below.

a

Remove the screws and b

Place the rear fireback in place. The side clips on both sides.

fireback holds the rear fireback in place -

5/16" Nutdriver

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAA d

Place the floor firebacks in place.

AAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAA hold the rear fireback while installing the side fireback.

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AA

AA

AA

AA

AA

AA

AAA

AAA

AAA

AAA

AAAAAAAAAAAAAAAAAAAAA c

Place the side firebacks in place. Secure using the screws and clips removed in step “a”.

Place the grate in place. Take care to prevent it from damaging the ceramic firebacks.

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

AA

AA

AA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAA

© Travis Industries 4070201 100-01182_002

48 Finalizing the Installation

(for qualified installers only)

Log Set Installation

Rear Log Installation

These pins insert into the holes on the bottom of the rear log.

Log Stop

(both sides)

Right Log Installation

Travis Industries

Place the rear log in place and slide it all the way back against the log stops.

4070201

The burner has a flat portion here with a ridge directly behind it.

Place the right log on the flat portion of the burner and push it back so it rests against the ridge.

Note how the notch on the right log hangs over the side of the burner.

Rotate the inward tip of the log forward so it is directly next to the burner holes.

100-01182_002

Finalizing the Installation

(for qualified installers only)

Left Log Installation

49

This hole and pin are not utilized.

When in place, the logs should look like this.

Place the left log so this pin inserts into the hole on the bottom of the log.

© Travis Industries 4070201 100-01182_002

50 Finalizing the Installation

(for qualified installers only)

Left Twig Installation

This hole is not utilized.

Place the left twig so the hole and slot fit over the pins on the rear and left log.

Right Twig Installation

Place the right twig so the hole fits over the pin on the rear log.

Move the front end of the right twig to the right. It should be resting on the middle portion of the right log.

VERIFY REAR LOG POSITION

With all the logs in place, verify the rear log is vertical and all the way back – this will insure proper air flow and prevent sooting.

Travis Industries 4070201 100-01182_002

Finalizing the Installation

(for qualified installers only)

Center Twig Installation

51

Front Twigs Installation

Place the center twig on the flat portion of the burner.

Place the front twigs along the front of the grate as shown (exact placement is not mandatory – make sure the twigs do not line up over any burner holes).

NOTE: If using the optional andirons, you may need to adjust twig placement.

Ember Installation

A bag of embers is provided to further enhance the firebox. Place the embers on the firebox floor and on the burner (especially over exposed screws on the burner). Do not place embers over any of the burner holes or air channels.

© Travis Industries 4070201 100-01182_002

52 Finalizing the Installation

(for qualified installers only)

LP Conversion Instructions

Install the conversion kit prior to installing the gas line to ensure proper gas use.

1 Remove the glass (see page 45). Remove the logs and coals (if installed - page 47). Remove the grate and firebacks (see page 47).

2 Remove the burner (see illustration below).

Remove the four screws holding the burner assembly in place.

A

A

Slide the burner to the left and up to remove.

A

A

A

Travis Industries

NOTE: The front of the burner support is removable. It may be removed to aid in burner alignment during re-assembly.

4070201 100-01182_002

Finalizing the Installation

(for qualified installers only)

3 Follow the directions below to replace the orifices.

a Slide the air shutters all the way to the left.

53

A

AAA

Rear Orifice

Front Orifice

Manifold b

Use a 1/2” open end wrench to unscrew both orifices.

c

Apply thread sealant to the LP orifices prior to installation. Use the chart below to identify the correct orifices.

1/2" Wrench

Rear Burner

Orifice

Front Burner

Orifice

Look here for the orifice identification

Front

Rear

LP

1.2mm

#55

NG

#45

#45

Manifold

5/16” d

Screw the LP orifice in so the orifice shoulder protrudes 5/16”

(indicating full insertion).

4 Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice a

Lift the pilot hood off the pilot assembly.

c

Remove the orifice and replace with the LP orifice. Screw the orifice all the way in and replace the pilot hood.

Orifice Identification:

LP (Propane) Orifice

35 b

Use a hex wrench to unscrew the orifice.

35

NG (Natural Gas) Orifice

62

5/32" Hex

© Travis Industries

NOTE: when re-attaching, this pin lines up with the notch in the pilot hood.

4070201 100-01182_002

54 Finalizing the Installation

(for qualified installers only)

5 Replace the firebox

components. Install the logs and embers.

Replace the glass.

a

Remove and discard the three screws using a slotted screwdriver of Torx T-20.

6 Remove the regulator from the front of the gas control valve. Replace with the propane regulator, using the new gasket and screws included with the regulator. NOTE: Leak test this area after the heater is installed, gas is connected, and the main burner is lit.

Slotted

Screwdriver

(or T-20 Torx)

c

Install the LP regulator. Use the screws included with the

LP regulator. Tighten to approximately 25 Lbs. torque.

b

Remove and discard the regulator, diaphram, spring and center post.

7 Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve.

Check the pilot (see the illustration below.

Adjust if necessary.

WARNING: When lighting or re-lighting the pilot, the glass must be removed (see page 45).

Slotted

Screwdriver

(or T-20 Torx)

To adjust the pilot flame, turn this screw (NOTE: if totally unscrewed gas will come out of this port). Clockwise lowers the flame while counter-clockwise raises it.

NOTE: Make sure the regulator gasket is correctly aligned before installation.

AAAAAA

AAAAAA

AAAAAA

AAAAAA

d

Place the LP label on the base of the fireplace near the gas control valve.

AAAAAA

AAAAAA

AAAAAA

AAAAAA

The pilot flame must contact the thermocouple and thermopile (see the illustration below). Adjust the pilot up or down as necessary.

Standard

Screwdriver

Travis Industries 4070201 100-01182_002

Optional Equipment

(for qualified installers only)

Grill Installation

Certain faces allow for installation of an upper and lower grill. Follow the directions below to install.

Upper Grill Installation

Hold the grill at an angle and insert the lower slot over the bushing on the fireplace (both sides). You may need press on the grill to get the tab over the bushing (this prevents the grill from accidentally falling off).

Swing the grill upwards to engage the second slot. You will need to lift the grill slightly to get it over the bushing. Once in place the grill is held in place by gravity.

55

Lower Grill Installation

A

A

AAA

AAA

AAA

AAA

AAA

AAA

AAA

AAA

Hold the grill at an angle and insert the lower slot over the bushing on the fireplace (both sides). You may need press on the grill to get the tab over the bushing (this prevents the grill from accidentally falling off).

Bend this the tab over on both sides. This is the end-stop for the lower grill, it allows the grill to swing forward.

© Travis Industries 4070201

Swing the grill upwards to engage the second slot. You will need to lift the grill slightly to get it over the bushing. Once in place the grill is held in place by gravity.

100-01182_002

56 Optional Equipment

(for qualified installers only)

Remote Control Receiver Installation (2 Options)

The instructions below detail installation of the optional remote control receiver. For operating instructions, refer to the instructions included with the remote.

OPTION # 1 - Remote Thermostat (99300653)

WARNING: Make sure the power cord does not contact the blower (if applicable) or the bottom of firebox (or other hot surface).

Attach the power cord to the electrical receptacle on the inside of the fireplace.

Use lock-ties or wire ties to shorten the power cord to approximately 12” length.

Place the receiver in a location to the left of the gas control valve

(near the front of the fireplae).

Attach the two reciever wires to the top and bottom posts on the gas control valve (orientation does not matter).

OPTION # 2 - Remote Thermostat (9930067

6)

Travis Industries

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAA

(near the front of the fireplae).

4070201 100-01182_002

Optional Equipment

(for qualified installers only)

Extra Room Power Heat Duct

(sku 98500769)

Special Instructions for 864 HH

Newer 864 HH fireplaces (SN 3407-001010 or greater) have an improved wiring harness and removable heat shields below the heat duct connections. The wiring harness is now routed through the snap disk, allowing the power heat duct to be turned on and off by the fireplace (see “Wiring

Instructions” on page 62). An additional knock-out was added to the fireplace to allow for the electrical line to be routed to the power heat duct (see below). The removable heat shields allow more heat to be routed to the power heat ducts (see below for details).

New Wire Hook-Up

A knock-out is provided on the left side of the fireplace for routing the sheathed cable (romex) from the inside of the firebox to the power heat duct. Use the strain relief

(included with the power heat duct) to secure the cable.

57

Cable to

Power Heat

Duct

Molex Connector

(attached to the wiring harness on the fireplace)

Molex Connector (included with heat duct kit) - use wire nuts to attach to the cable.

New Removable Heat Shield (improves heat output to power heat duct)

Remove and discard the power heat duct cover plate (one or both sides).

Remove and discard the circular cover plate attached to the heat shield.

© Travis Industries 4070201 100-01182_002

58 Optional Equipment

(for qualified installers only)

Installation Overview

The optional heat duct allows the fireplace to transfer heat to separate locations in the home.

Installation should take place prior to installing drywall.

Warning: This kit must be installed as specified in these instructions. Do not modify any component.

Warning: Use of any external blower other than the Travis Power Heat Duct Blower will void the warranty and listing of this appliance and may create a fire hazard.

Note: The power heat duct must be installed by a qualified service technician.

Note:

Note:

Note:

Some building codes may require the use of firestop spacers whenever the duct passes from room to room.

When routing ducts through a cold area (e.g. crawl space) we recommend insulating the duct with fiberglass insulation. If paper-backed insulation is used, the paper can not contact the duct.

One or two het duct kits may be used.

Junction Box

Electrical Source

Maximum Duct

Length = 20'

Floor

Boot

Rheostat

(with cover plate)

Use 10” x 3-1/4” wall stack (duct) when passing through tight areas.

Blower

Box

Duct Adapter

(6” Round to 10” x 3-1/4”)

6" Duct

Starter Ring

Grill

Wall Adapter

(for use on

2 x 4 walls)

Travis Industries 4070201 100-01182_002

Optional Equipment

(for qualified installers only)

59

Duct Installation Instructions

Determine the route for the heat duct using the illustration below as a guide.

NOTE: to maximize performance.

When the duct penetrates the fireplace enclosure vertically and the top of the enclosure is within 36” of the top of the fireplace, a firestop spacer that maintains a 1/2” clearance between all sides of the duct and any combustible material must be used.

A

A

A

1/2”

Blower Box

AA

AA

AA

AAAAAAAAAAAAAAAAAA

AAAAAAAAA

AAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAA

A

A

A

A

A

A

A

A

A

A

A

A

20’ Maximum

AA

AA

AA

A

A

Length

Duct Adapter

A

A

A

A

A

A

(6” Round to 10” x 3-1/4” - included with the power heat vent kit)

Co-Axial Vent

(for intake air and exhaust)

A

A

A

A

A

A

A

A

A

A

A

A

A

A

0” Clearance to

Combustibles

A

A

A

A

Use 10” x 3-1/4” wall stack

(duct) when passing through tight areas.

A

A

A

A

A

A

A

A

A

A

A

AAAAAAAAAAAAAAAAAA

Wall or Ceiling Mounting a

5-1/4"

Cut a hole between wall framing members for the blower assembly.

AA

AA

AA

AA

AA

AA

AA

A

A

A

A b

Attach the wall mounting brackets to the blower box.

Mount the bracket to these holes for 2 x 4 walls

Mount the bracket to these holes for 2 x 6 walls c

Slide the blower, with wires, into the hole cut in step "a". Attach with four screws.

A

A

A

A

A

A

AA

AA

AA

AA

AA

* This blower was designed for framing on 16" centers. Construct additional framing if needed.

If the blower is installed prior to the drywall only a 14" opening is required. If installed after the drywall is in place, the drywall to the sides of the blower will need to be patched.

© Travis Industries 4070201 100-01182_002

60 Optional Equipment

(for qualified installers only)

Floor Mounting a

Cut a hole between floor joists for the blower box.

b

Attach the floor boot to the blower box with the included screws.

5-1/4"

AAAA

A

A

14"

The screws attach to either of these pairs of holes. Use the upper pair for thick flooring, the lower pair for thin flooring.

c

Slide the blower into the hole cut in step "a". Attach with four screws.

AAAA

AAAA

AAAA

AAAA

Attach the starter ring to the fireplace following the directions below (use the most convenient side

- 864TRV has only one opening on the right side).

1/4" Nutdriver

Starter Ring

Remove and discard the cover plate.

Bend the tabs on the bottom of the starter ring up to lock it in place.

Travis Industries 4070201 100-01182_002

Optional Equipment

(for qualified installers only)

Install the air duct. Each section, when joined, must be attached with three screws and aluminum duct tape (U.L. 181A-P or equivalent). Secure the duct if it is in an area where it may sag or become dislodged.

61

NOTE: The air duct has a 0” clearance to combustibles.

Secure all ducting together with screws.

Then seal the seams with aluminum duct tape (U.L. 181A-P or equivalent).

Attach the grill (and wall adapter, if necessary).

Screws

(included with this kit)

AA

AA

AA

AA

AA

Phillips

Screwdriver

Grill

A

A

A

A

A

A

(for use when the blower box protrudes from the wall - primarily on 2 x 4 walls)

© Travis Industries 4070201 100-01182_002

62 Optional Equipment

(for qualified installers only)

Wiring Instructions

Warning: All wiring should be done by a qualified electrician and shall be in compliance with local codes and with the current National Electric Code ANSI/NFPA 70.

Warning: Make sure the fireplace electrical circuit is disabled prior to working on electrical hookup.

Wiring Diagram - 864 HH*, 44 DV XXL, and 36 DV

Heat Duct

Rheostat

Fireplace Blower

Snap Disk

Heat Duct

Blower

Hot

(black)

Common

(white)

Hot

(black)

Common

(white)

Molex

Connector

Molex

Connector

Hot

(black)

Common

(white)

Hot

(black)

Common

(white)

Hot

(black)

Common

(white)

Hot

(black)

Common

(white)

Ground

(green)

Ground

(green)

Ground

(green)

Ground

(green)

Ground

(green)

Ground

(green)

Rheostat

Junction

Box

Blower

Junction

Box Grounded to Blower

Fireplace

Blower

Fireplace

Rheostat

Hot

(black)

Common

(white)

Ground

(green)

Optional Second Heat

Duct (same rheostat and blower wiring as above)

Wiring Diagram -864TRV

* 864 HH SN 3407-001010 or greater. 864 HH SN 3407-001009 or less uses wiring similar to the

864TRV.

Hot

(black)

Common

(white)

Ground

(green)

Rheostat

Junction Box

Hot

(black)

Common

(white)

Ground

(green)

1 Follow the directions below to wire the blower box.

a

Remove the cover from the blower box.

b

Phillips

Screwdriver

Blower

Assembly

Standard

Screwdriver

Insert sheathed cable through the cable clamp.

After the wires have been connected tighten the clamp to secure the cable.

c Attach the hot (black) and common (white) wires to the leads coming from the wires (use wire nuts).

d

Secure the ground wire to the ground stud inside the blower box by tightening the included nut over the ground wire. Re-attach the cover removed in step

"a".

Ground Wire

Travis Industries 4070201 100-01182_002

Optional Equipment

(for qualified installers only)

63

2 Follow the directions below to wire the rheostat. NOTE: There are two types of junction boxes, use the appropriate junction box for your installation.

a

From

Blower Box

Force the sheathed cable through one of the locking flaps on the junction box (repeat for the other cable). Some force is needed.

The flap will lock the cable in place.

NOTE:Two junction boxes are included - use the best box for your installation.

b

Attach the common (white) wires together. Attach the ground

(exposed or green) wires together.

Then attach each of the hot (black) wires from the cables to the two wires on the rheostat (orientation does not matter). Carefully pack the wires into the junction box.

c Attach the cover plate

(either white or beige) with the included screws. Slide the knob (either white or beige) over the rheostat shaft.

Standard

Screwdriver

To Fireplace (36DV & 44 DV)

To Power Supply (864TRV)

3 Run the free wire from the rheostat junction box to the power supply. The thermodisk included with this kit may be discarded (it is not used on this fireplace).

Operating Instructions

Allow the fireplace to reach normal operating temperature. Then use the wall-mounted rheostat to operate the blower speed.

864TRV: Turn the blower off when the fireplace is not in operation.

OFF

Turn the dial all the way counterclockwise until it clicks off.

HIGH

The high position is all the way counterclockwise, without clicking off.

LOW

Turn the dial all the way clockwise.

MAINTENANCE INSTRUCTIONS

Once a year the grill should be removed and the blower area cleaned. Use a vacuum to clean around the squirrel-cage blower, being careful not to damage any of the blades.

Phillips

Screwdriver

A

A

A

A

A

A

A

A

A

A

AA

AA

AA

AA

AA

Use a vacuum cleaner to remove any debris from the power vent blower.

Grill

© Travis Industries 4070201 100-01182_002

64 Optional Equipment

(for qualified installers only)

Accent Light Installation

(sku 94400100)

Make sure power to the fireplace has been turned off prior to installation (disable the service breaker).

Do not connect 110-120 VAC to the gas control valve or the on/off circuit on this fireplace.

The accent light must be removed to install the rear fireback. The remaining firebacks are installed after the accent light is in place.

1 Remove the firebacks (if already installed – see page 47). Remove the burner (see 52 for details).

2 Remove the cover plate following the directions below.

A

A

AA

AA

Cover Plate

3 Place the rear fireback in position and install the accent light assemblies following the directions below.

Rear Fireback

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AA

AA

Accent Light Assemblies

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA

Magnetic Nutdriver

Travis Industries 4070201 100-01182_002

Optional Equipment

(for qualified installers only)

4 Install the strain relief plate to the firebox floor following the directions below.

= a Insert the four wires through the strain relief plate (NOTE: Put the larger, male connectors through first).

b Secure the wires using the included strain relief

(wrap the strain relief over the wires, compress with pliers, then insert into the hole).

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA d

AAAAAAAAAAAAAAAAAAAAAAAAAA

A

A the pilot bracket that can be bent down to secure the wiring. All wiring must be secured away from the burner.

A

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA c

Secure the strain relief plate to the firebox floor with the screws removed earlier.

65

5 Restore the firebox to the correct configuration (replace the burner, firebacks, logs).

If using the optional wall-mounted rheostat, follow the directions on the following page "Wall Mounted

Rheostat".

6 Install the rheostat assembly following the directions below.

© Travis Industries

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAA b

Attach the quick-connects from the rheostat to the quick-connects from the accent light assemblies

(orientation does not matter). Plug the rheostat into the receptacle.

AAAAAAAAAAAAAAAAAAAAAAAAAAA

AAAAAAAAAAAAAAAAAAAAAAAAAAA a

Attach the rheostat assembly to the fireplace with the included screws.

4070201 100-01182_002

66 Optional Equipment

(for qualified installers only)

Optional Wall-Mounted Rheostat

NOTE: Many areas require all wiring to be installed by a qualified electrician. Check with your local building official for any requirements in your area.

1 Remove the rheostat from the rheostat assembly.

2 Detach the three wires leading from the rheostat (secured with wire nuts). Attach the rheostat assembly to the fireplace (see the illustration on the previous page). Attach the quick connects from the rheostat to the quick connects from the accent light assemblies (see the illustration on the previous page).

3 Attach three suitable wires (insulated & sheathed) to the rheostat. Install the rheostat into a junction box at the remote location. Run the wire from the junction box to the fireplace. Use the included wire clamp to secure the wiring as it passes through the fireplace (see the illustration below).

4 Connect the three wires from the rheostat to the three wires on the wiring harness disconnected in step 2

(use the included wire nuts). Plug the rheostat assembly into the receptacle inside the fireplace.

Rheostat

(removed from rheostat assembly)

Junction Box

Knob (included)

Wire Clamp (included)

A 7/8” diameter hole is provided on this cover plate (both sides). If this hole is already used for a gas inlet, you can drill an additional 7/8” hole in this cover plate.

Accent Light Operation

OFF

Turn the dial all the way counter-clockwise until it clicks off.

NOTE:

The accent light responds best when turned to high, then turned down to the desired light level.

LOW

Turn the dial 180° clockwise until the light begins to glow.

HIGH

The high position is all the way clockwise.

Rheostat

Assembly

Travis Industries 4070201 100-01182_002

Optional Equipment

(for qualified installers only)

67

© Travis Industries 4070201 100-01182_002

68

Index

Index

Additional Items Required............................................ 7

Air Shutter Adjustment ................................................ 44

Altitude Considerations ............................................... 21

Approved Vent Configurations ...................................... 23

Approved Vent ........................................................... 22

Clearances................................................................ 11

Converting the Fireplace to Top Vent Configuration ......... 9

Corner Installations - Rear Vent Configuration ................ 15

Corner Installations - Top Vent Configuration.................. 16

Diffuser Plate Adjustment............................................ 25

Dimensions ............................................................... 6

Drywall Installation...................................................... 33

Electrical Connection (required) .................................... 19

Exhaust Restrictor Adjustment ..................................... 23

Facing Overview......................................................... 34

Facing Requirements.................................................. 33

Features ................................................................... 6

Fireback and Grate Installation ..................................... 47

Fireplace Placement Requirements............................... 11

Fuel ......................................................................... 17

Gas Inlet Pressure ..................................................... 17

Gas Line Connection .................................................. 17

Gas Line Location ...................................................... 17

Gas Line Requirements............................................... 17

Glass Frame Removal and Installation .......................... 45

Grill Installation .......................................................... 55

Hearth Requirements.................................................. 32

Heating Specifications ................................................ 6

Index ........................................................................ 68

Installation Example - Build-In with Horizontal Termination. 42

Installation Options..................................................... 6

Installation Overview ................................................... 7

Intake Restrictor Adjustment........................................ 24

Listing Details............................................................ 2

LP Conversion Instructions.......................................... 47

Mantel Requirements .................................................. 40

Massachusetts Requirements ...................................... 8

Minimum Framing Dimensions - Rear Vent Configuration............................12

Minimum Framing Dimensions - Top Vent Configuration..............................13

Nailing Brackets ......................................................... 14

Overview ................................................................... 2

Packing List............................................................... 7

Pilot Flame Inspection ................................................ 43

Extra Room Power Heat Duct....................................... 57

Raised Fireplaces ...................................................... 11

Rear Vent Configuration with Horizontal Termination (no vertical rise)........ 26

Rear Vent Configuration with Horizontal Termination (with vertical rise)....... 27

Rear Vent Configuration with Vertical Termination............ 28

Recommended Installation Procedure ........................... 7

Remote Control Receiver Installation (2 Options)............ 56

Restrictor Position...................................................... 23

Safety Precautions ..................................................... 4

Starting the Pilot Flame............................................... 43

Steps for Finalizing the Installation................................ 43

Termination Requirements ........................................... 31

Thick Facing Installation with FPX Arched Faces ............. 38

Thick Facing Installation .............................................. 37

Thin Facing Installation ............................................... 35

Top Vent Configuration with Horizontal Termination .......... 29

Top Vent Configuration with Vertical Termination ............. 30

Vent Clearances ........................................................ 21

Vent Installation ......................................................... 22

Vent Requirements..................................................... 21

Wall Switch Installation................................................ 20

Wall Switch or Thermostat Installation ........................... 20

Wiring Diagram (Blower and Power Heat Duct) ................ 62

Wiring Diagram (Millivolt System) ................................. 20

Travis Industries 4070201 100-01182_002

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement