Regency Fireplace Products Plateau PTO30IST User manual

Add to My manuals
36 Pages

advertisement

Regency Fireplace Products Plateau PTO30IST User manual | Manualzz

Regency Plateau

®

Series

Outdoor Decorative Gas Appliances

Owners &

Installation Manual

MODELS: PTO30CFT

PTO30IST

PTO30CKT

LISTINGS AND CODE APPROVALS

These gas appliances have been tested in accordance with AS4565 / AS4558 and have been certified by the IAMPO

Oceana for installation and operation as described in these Installation and

Operating Instructions.

Your unit should be serviced annually by an authorised service person.

www.regency-fire.com

WARNING: FOR OUTDOOR USE ONLY

WARNING:

If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

WARNING:

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.

Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.

Installation and service must be performed by a authorised installer, service agency or the gas supplier, in accordance with this manual.

WARNING - FOR YOUR SAFETY

What to do if you smell gas:

•Shut off gas to the appliance.

•Do not try to light any appliance.

•Extinguish any open flame.

•If odor continues, keep away from the appliance and immediately call your gas supplier or fire department.

•Do not touch any electrical switch: do not use any phone in your building.

•Immediately call your gas supplier from a neighbour's phone.

•Follow the gas supplier's instructions.

•If you cannot reach your gas supplier, call the fire department.

WARNING:

Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

A LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

Installer: Please complete the details on the back cover and leave this manual with the homeowner.

Homeowner: Please keep these instructions for future reference.

919-065e

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4

04.07.15

2

To the New Owner:

Congratulations!

You are the owner of a state-of-the-art Outdoor Decorative Gas Appliance by REGENCY

®

. The

Plateau

®

Series Outdoor Decorative Gas Appliance has been designed to provide you with all the charm of a fire at the flick of a switch. The Plateau

®

Series Outdoor Decorative Gas Appliance has been approved by IAPMO for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.

Please take a moment now to acquaint yourself with these instructions and the many features of your Regency

®

decorative gas appliance.

X

X

X

DANGER

CARBON MONOXIDE HAZARD

This appliance can produce carbon monoxide which has no odor.

Using it in an enclosed space can kill you.

Never use this appliance in an enclosed space such as a camper, tent, car or home.

WARNING

HOT GLASS

WILL

CAUSE BURNS

DO NOT TOUCH

GLASS

UNTIL COOLED

NEVER

ALLOW CHILDREN

TO TOUCH GLASS

Regency Plateau™ Series Outdoor Gas Fireplace

SAFETY LABEL

Copy of Safety Decal .....................................................4

DIMENSIONS

Unit Dimensions - coffee table .......................................5

Unit Dimensions - island table .......................................6

Unit Dimensions - cocktail table ....................................7

INSTALLATION

Important Message ......................................................8

Before You Start ............................................................8

General Safety Information............................................8

Installation Checklist .....................................................9

Locating Your Outdoor decorative gas appliance ..........9

Minimum Clearances to combustibles .........................10

High Elevation ............................................................. 11

Gas Line Installation .................................................... 11

Pilot Adjustment ........................................................... 11

Gas Pipe Pressure Testing .......................................... 11

886 S.I.T. Valve Description ......................................... 11

Aeration Adjustment .................................................... 11

Wiring Diagram ............................................................12

Gas Connection ..........................................................13

Conversion from Ng to LPG / uLpg .............................14

PTO30cft -Coffee Table leg installation ......................16

LP Tank installation - PTO30cft only ............................17

LP Tank Installation ....................................................18

PTO30IST/PTO30CKT ONly ......................................18

LP Tank removal ........................................................18

Switch connection........................................................19

Battery Install ...............................................................19

Table top Installation - coffee table unit .......................20

Table top installation ...................................................21

(For Island and cocktail units only) ..............................21

Glass crystal installation ............................................22

Optional Volcanic stones Installation On Burner .........23

Glass surround Installation ..........................................24

Riser Installation ..........................................................25

(to convert Island into cocktail table) ...........................25

Plateau

®

table cover Installations ................................27

TABLE OF CONTENTS

OPERATING INSTRUCTIONS

Operating Instructions .................................................28

Lighting Procedure ......................................................28

Shutdown Procedure ...................................................28

First Fire ......................................................................28

Indoor storage of cylinders ..........................................28

Identification for leaks .................................................28

Copy of Lighting Plate Instructions ..............................29

Maintenance Instructions.............................................30

Switch replacement .....................................................31

Valve assembly replacement .......................................32

Digital fireplace control replacement ...........................33

Battery replacement ....................................................33

PARTS

Parts ............................................................................34

WARRANTY

Limited Warranty: ......................................................36

33

Regency Plateau™ Series Outdoor Gas Fireplace

SAFETY LABEL

This is a copy of the label that accompanies each

Plateau

®

Series Outdoor decorative gas appliance.

We have printed a copy of the contents here for your review.

NOTE: Regency

®

units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

TO BE INSTALLED BY AN AUTHORISED PERSON

Primarily a decorative appliance - not certified as a space heater.

4

THIS APPLIANCE SHALL NOT BE INSTALLED OR USED INDOORS

Regency Plateau™ Series Outdoor Gas Fireplace

UNIT DIMENSIONS - COFFEE TABLE

8

DIMENSIONS

TOP VIEW

38”(965mm)

2-1/16”(52mm)

4.5KG TANK

40-5/8”(1030mm)

SIDE VIEW

2-9/16”(64mm)

3-5/8”(91mm)

4.5KG TANK

16-11/16”(423mm)

END VIEW

5

Regency Plateau™ Series Outdoor Gas Fireplace

DIMENSIONS

UNIT DIMENSIONS - ISLAND TABLE

62" (1575mm)

6

14-1/4" (361mm)

BURNER

TO

OUTER EDGE

9KG TANK

20lb tank

12-3/16" (309mm)

GLASS

TO

OUTER EDGE

1”

(25mm)

1-5/8”

(39mm)

6-3/16”

(156mm)

28-7/8”

(733mm)

40-3/8”

(1031mm)

3-1/8”

(79mm)

Floor to bottom of LP tank

36" (914mm)

20-11/16”

(525mm)

Floor level

Regency Plateau™ Series Outdoor Gas Fireplace

62" (1575mm)

UNIT DIMENSIONS - COCKTAIL TABLE

DIMENSIONS

14-1/4" (361mm)

BURNER

TO

OUTER EDGE

12-3/16" (309mm)

GLASS

TO

OUTER EDGE

TOP VIEW

37

15

16 "

963mm

36"

914mm

12

13

16 "

325mm

49

1

8 "

1248mm

SIDE VIEW

29

1

4 "

742mm

END VIEW

7

Regency Plateau™ Series Outdoor Gas Fireplace

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The Plateau ® Series Outdoor Decorative Gas

Appliance must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this decorative gas appliance is installed in compliance with manufacturers instructions and all applicable codes.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI

Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULD

BE DONE BY AN AUTHORIZED SERVICE

PERSON. THE APPLIANCE SHOULD

BE INSPECTED BEFORE USE AND AT

LEAST ANNUALLY BY A PROFESSIONAL

SERVICE PERSON. IT IS IMPERATIVE

THAT CONTROL COMPARTMENTS,

BURNERS AND CIRCULATING AIR

PASSAGEWAYS OF THE APPLIANCE

BE KEPT CLEAN.

ANY GUARD OR OTHER PROTECTIVE

DEVICE REMOVED FOR SERVICING

THE APPLIANCE MUST BE REPLACED

PRIOR TO OPERATING THE APPLIANCE

WARNING: FAILURE TO INSTALL THIS

APPLIANCE CORRECTLY WILL VOID

YOUR WARRANTY AND MAY CAUSE A

SERIOUS FIRE.

CHILDREN AND ADULTS SHOULD BE

ALERTED TO THE HAZARDS OF HIGH

SURFACE TEMPERATURES, ESPE-

CIALLY THE DECORATIVE GAS APPLI-

ANCE GLASS AND FACEPLATE, AND

SHOULD STAY AWAY TO AVOID BURNS

OR CLOTHING IGNITION.

THIS APPLIANCE SHALL BE USED

ONLY OUTDOORS IN A WELL-VENTI-

LATED SPACE AND SHALL NOT BE

USED IN A BUILDING, GARAGE OR ANY

OTHER ENCLOSED AREA.

SOLID FUELS SHALL NOT BE BURNED

IN THIS APPLIANCE.

DO NOT USE THIS APPLIANCE IF

ANY PART HAS BEEN UNDER WATER.

IMMEDIATELY CALL A QUALIFIED

SERVICE TECHNICIAN TO INSPECT

THE APPLIANCE AND TO REPLACE

ANY PART OF THE CONTROL SYSTEM

AND ANY GAS CONTROL WHICH HAS

BEEN SUBMERGED UNDER WATER.

CLOTHING OR OTHER FLAMMABLE

MATERIAL SHOULD NOT BE PLACED

ON OR NEAR THE APPLIANCE.

YOUNG CHILDREN SHOULD BE CARE-

FULLY SUPERVISED WHEN THEY ARE

IN THE SAME AREA AS THE APPLI-

ANCE. TODDLERS, YOUNG CHILDREN

AND OTHERS MAY BE SUSCEPTIBLE

TO ACCIDENTAL CONTACT BURNS. A

PHYSICAL BARRIERS IS RECOMMEND-

ED IF THERE ARE AT RISK INDIVIDUAL

IN THE HOUSE. TO RESTRICT ACCESS

TO A DECORATIVE GAS APPLIANCE

OR STOVE, INSTALL AN ADJUSTABLE

SAFETY GATE TO KEEP TODDLERS,

YOUNG CHILDREN AND OTHER AT RISK

INDIVIDUALS OUT OF THE ROOM AND

AWAY FROM HOT SURFACES.

WARNING: APPLIANCES CONNECTED

TO A FIXED GAS SUPPLY MUST BE

RESTRAINED TO PREVENT DAMAGE

OF THE GAS SUPPLY CONNECTIONS.

GENERAL SAFETY

INFORMATION

1) The installation must conform with local codes or, in the absence of local codes, with

CAN/CSA-B149.1, Natural Gas and Propane

Installation Code or CAN/CSA-B149.2, Propane installation code the Natural Gas Fuel Code,

ANSI Z223.1/NFPA 54.

2) See general construction and assembly instructions. The appliance should be enclosed.

3) The LP-gas supply cylinder to be used must be:(a)Constructed and marked in accordance with the U.S. Department of Transportation

(D.O.T.) Specifications for LP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous

Goods and Commission, CAN/CSA-B339 as applicable; (b)Provided with a listed overfilling prevention device; and(c)Provided with a cylinder connection device compatible with the connection for the appliance.

4) Inspect the burner before each use of the appliance for blockage and any signs of deterioration.

5) DO NOT SIT OR STAND ON DECORATIVE

GAS APPLIANCE

6) To prevent injury, do not allow anyone who is unfamiliar with the operation to use the decorative gas appliance.

7) Wear gloves and safety glasses for protection while doing required maintenance.

8) Maximum gas inlet pressure = 1/2 psig.

9) Under no circumstances should this appliance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

10) Installation and any repairs to this appliance should be done by a qualified service person.

A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

11) Under no circumstances should any solid fuels

(wood, paper, cardboard, coal, etc.) be burned in this appliance.

12) The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).

13) The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids).

It is highly recommended to protect the interior from moisture (rain, snow). Cover the enclosure opening when not in use. This decorative gas appliance is only for use with the type of gas indicated on the rating plate. This decorative gas appliance is not convertible for use with other gases, unless a certified kit is used.

14) Cover must be removed when burner is in

operation.

15) When not using appliance for extended periods of time - turn off gas supply.

16) The 4 levelling legs or optional casters on this appliance must not be removed. These are for safety and must remain on the appliance.

14) Appliances incorporation a live fuel effect, and designed with luminous flames, may exhibit slight carbon deposition.

Emissions from burning wood or gas could contain chemicals known to the State of

California to cause cancer, birth defects or other reproductive harm.

8

Regency Plateau™ Series Outdoor Gas Fireplace

INSTALLATION

CHECKLIST

Please refer to the requirements of

AS / NZS5601 and local authorities.

1) Appliance is factory equipped for Natural Gas.

When using Propane, see LP conversion section in this manual. For LP - use a maximum 11 pound tank or direct hard pipe from an external

LP supply. Complying to AS5601.

INSTALLATION

LOCATING YOUR

OUTDOOR DECORATIVE GAS APPLIANCE

THE COFFEE TABLE REQUIRES THE INSTALLATION OF THE DECORATIVE GLASS

SURROUND KIT TO REDUCE THE RISK OF HARM TO CHILDREN

1) When selecting a location for your decorative gas appliance, ensure that the clearances are met.

2) This appliance must be installed in an open-air situation with natural ventilation, without stagnant areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.

2) Locate appliance:

3) Certain materials or items, when placed under or near the appliance, will be subjected to radiant heat and could become damaged.

a) Refer to "Locating Your Outdoor decorative gas appliance" section b) Clearances to Combustibles (Refer to

"Clearances" section)

4) Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used shall comply with one of the following:

An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover.

3) Gas Connection - for ease of installation and gas connection, remove left side panel

(one facing ON/OFF switch. Test for leaks.

.

4) Install 4 "AA" batteries into battery pack and replace into battery compartment holder.

DO NOT USE A 9V battery.

5) Connect the ON/OFF switch wires to the switch.

6) Install standard and optional features. Refer to the following sections: a. Tabletop Installation

b. Glass Crystals c. Volcanic Stone Installation (optional)

d. Glass Surround Installation e. Weather Cover Installation

7) Final check.

This includes:

1) Clocking the appliance to ensure the correct firing rate (rate noted on label), after burning appliance for 15 minutes.

Within a partial enclosure that includes an overhead cover and no more that two walls.

2) If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

Within a partial enclosure that includes an overhead cover and more than two walls, the following shall apply:

At least 25% of the total wall area is completely open, and

At least 30% of the remaining wall area is open and unrestricted

THIS APPLIANCE SHALL ONLY BE USED

IN ABOVE GROUND OPEN AIR SITUATION

WITH NATURAL VENTILATION, WITHOUT

STAGNANT AREAS, WHERE GAS LEAK-

AGE AND PRODUCTS OF COMBUSTION

ARE RAPIDLY DISPERSED BY WIND AND

NATURAL CONVECTION.

30% or more in total of the remaining wall area is open and unrestricted.

In the case of balconies, at least 20% of the total wall area shall be and remain open and unrestricted.

WARNING: DO NOT BUILD FRAME FOR

HOUSING CYLINDER UNLESS COMPLI-

ANCE TO AS 4565 AND AS/NZS 5601.1 ARE

ASSURED.

Open side at least 25% of total wall area

9

Regency Plateau™ Series Outdoor Gas Fireplace

INSTALLATION

MINIMUM CLEARANCES TO COMBUSTIBLES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this decorative gas appliance be installed only in accordance with these instructions.

Caution Requirements

The top, back and sides of the decorative gas appliance are defined by standoffs. The metal ends of the standoff may

NOT be recessed into combustible construction.

WARNING

Fire hazard is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this decorative gas appliance be installed only in accordance with these instructions.

Clearance:

A: Back wall

B: Sidewall

C: Ceiling

D

1

: Floor

D

2

: Floor

E: Alcove Width

F: Alcove Depth

Notes:

Plateau

®

Series Clearance Requirements

Dimension

17" (432mm)

Measured From:

Burner to back wall

17" (432mm)

45" (1143mm)

Burner to sidewall

Burner to Ceiling

0" When using supplied leveling legs or optional casters.

1"(25mm) Unit Base to Floor

84"(2134mm)

60" (1524mm)

0"

Wall to Wall (Minimum)

Front to Back Wall (Maximum)

No Hearth Required

A

C

B

D

F

E

Alcove

10

Regency Plateau™ Series Outdoor Gas Fireplace

PLATEAU

®

SERIES-NG SYSTEM

DATA

Max. Supply Pressure 14" WC (3.49 kpa)

Min. Supply Pressure 5" WC (1.25 kpa)

Manifold Pressure 3.5" WC (0.87 kpa)

Manifold Pressure -Low 1.6" WC (0.40 kpa)

Orifice Size

Minimum Input

Maximum Input

#25 DMS

37 mj.

55 mj.

PILOT ADJUSTMENT

Periodically check the pilot flames. Correct flame pattern has two strong blue flames: 1 flowing around the flame sensor and 1 flowing across the burner (it does not have to be touching the burner).

Burner

Flame Sensor

INSTALLATION

886 S.I.T. VALVE

DESCRIPTION

1) Manual high/low adjustment

2) Pilot adjustment

3) Outlet Pressure Tap

4) Inlet Pressure Tap

5) Pilot Outlet

6) Main Gas Outlet

7) Main Gas Inlet

PLATEAU

®

SERIES-LPG/ULPG

SYSTEM DATA

Max. Supply Pressure 14" WC (3.49 kpa)

Min. Supply Pressure

Manifold Pressure

11" WC (2.73 kpa)

10" WC (2.49 kpa)

Manifold Pressure-Low 6.4" WC (1.59 kpa)

Orifice Size #45 DMS

Minimum Input 40 mj.

Pilot Ignitor

Note: If you have an incorrect flame pattern, contact your Regency

®

dealer for further instructions.

Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact

with the rear burner or flame sensor.

Maximum Input 55 mj.

HIGH ELEVATION

This unit is approved for altitude 0 to 4500 ft. (CAN/

CGA 2.17-M91).

GAS PIPE PRESSURE

TESTING

4

3

The appliance must be isolated from the gas supply piping system by closing its individual approved manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.

GAS LINE

INSTALLATION

Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code or AS/NZS 5601.1.

The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.

2

1

inlet and manifold pressures should be checked using the valve pressure ports on the valve.

For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.

1) Make sure the valve is in the "OFF" position.

When using copper or flex connectors use only approved fittings. Always provide a union so that gas lines can be easily disconnected for servicing.

Flare nuts for copper lines and flex connectors are usually considered to meet this requirement.

2) Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a

1/8" wide flat screwdriver.

3) Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.

NOTE: A shutoff / dante valve should be supplied in or near the unit (or as per local codes) for ease of servicing this appliance.

IMPORTANT: Always check for gas leaks with a soap and water solution or gas leak detector.

Do not use open flame for leak testing.

4) Light the pilot and turn the valve to "ON" position.

5) The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.

Properly locate lines/hoses out of pathways or arches where the hose may be subject to damage.

6) When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver.

Note: Screw should be snug, but do not over tighten.

4

5

3

6

2

1

7

AERATION ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame.

Minimum Air Shutter Opening:

Fully Closed NG

1/2" LPG/ULPG

Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.

11

Regency Plateau™ Series Outdoor Gas Fireplace

5

6

7

INSTALLATION

WIRING DIAGRAM

This appliance does not require a 120V A.C. supply for operation.

Proflame System

0.886.001

Proflame Valve

Standard Main On/Off Switch or Optional Wall Switch

Important: The AA batteries in the battery pack operate the burner switch. If the batteries become weak they will need to be replaced with quality alkaline batteries. This unit will not operate without AA batteries.

12

Regency Plateau™ Series Outdoor Gas Fireplace

GAS CONNECTION

1) Remove end panel (end with the ON/OFF switch). Panels are held in place by magnets. Place panel on a soft clean surface.

3) Connect gas line..

INSTALLATION

Gas connection

@ unit

4) Check all gas connections (both valve train & propane tank or NG source) under normal operating pressure, for leaks, with soapy water.

NOTE: If soap bubbles, this would indicate a gas leak.

5)

Reverse steps 1 & 2.

2) Remove long side panel (left panel if you are facing end with ON/OFF switch) to access the 3/8" fitting to the gas control.

NOTE:

a) WARNING: Cylinder compartment must be kept separate from combustion chamber - Reference to AS/NZS 5601.1.

b) Remote cylinder compartment installation, materials, ventilation and securing of pipe work (fixed and flexible ) must comply with AS/NZS

5601.1.

c) Refer to AS/NZS 5601.1 for flex hoses.

d) Refer to AS4631 for flexibility connectors.

e) AS 4617 for manual shut off valves.

f) WARNING: Cylinder must not be stored OR placed in an area that does not comply to AS/NZS 5601.1

g) The installation and use of approved mechanical isolation valves is required.

13

Regency Plateau™ Series Outdoor Gas Fireplace

INSTALLATION

PLATEAU SERIES

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

4) Remove burner orifi ce with a 1/2" wrench. Use another wrench to hold on to the elbow behind the orifi ce. Discard orifi ce.

Each Kit contains one LPG/ULPG Conversion Kit

Conversion Kit # 376-972 Contains:

Qty. Part # Description

1 904-655 Burner Orifi ce #45

1 904-529 5/32" Allen Key

1 918-590 Decal "Converted to LPG"

1 908-528 Red "LP" label

1 911-009 Hi/Lo conversion LP For 886

1 911-089 Propane Hose & Regulator 48 in.

1 919-084 Instruction Sheet

1) Shut off the gas and allow unit to cool to room temperature.

5) Pull off the pilot cap to expose the pilot orifi ce. Using a 5/32" allen key, remove pilot orifi ce and replace with LP pilot orifi ce.

2) Remove burner buy removing 6 screws in locations shown below. If glass crystals are installed, move the crystals out of the way to reveal screws.

3) Slide the burner to the left, away from the pilot assembly and lift out.

Burner orifi ce

14

919-084

Pilot Cap

1

6) Re-install pilot cap.

7) Reinstall burner assembly.

8) Adjust aeration accordingly.- see aeration adjustment section manual for details.

Regency Plateau™ Series Outdoor Gas Fireplace

10/13/11

PLATEAU SERIES

9) Remove end panel (panel w/ switch) from unit.

INSTALLATION

14) Remove NG gas line, if installed - replace with LP regulator and quick connection.

Gas connection

@ unit

10) Remove two screws to remove valve cover panel.

15) Check all gas connections (both valve train & LP tank) under normal operating pressure, for leaks, with soapy water.

NOTE: If soap bubbles, this would indicate a gas leak.

16) Install LP tank (see LP tank installation in this manual).

17) Check inlet and outlet pressures.

18) Check operation of fl ame control.

11) Remove Hi/Lo pressure regulator by removing 2 screws as shown below.

Reverse steps to install LP pressure regulator.

WARNING:

When connecting the regulator end of the hose to the cylinder valve turn

'POL' connection counter clockwise. If rubber hose type 'POL', tighten fi rmly by hand—DO NOT OVER TIGHTEN.

Do not use a tool to tighten connection—using a tool may result in damage to the connection resulting in a gas leak, potentially causing serious risk.

IMPORTANT:

When connecting or replacing gas cylinder, hose assembly, or fi ttings, all connections must be checked for gas leaks using soapy water solution and a spray bottle. After completing gas leak test, thoroughly clean off all remaining soap and water solution with clean water. Some detergents are corrosive. Contact local authority if gas leaks persist.

12) Attach the label “This unit has been converted to ULPG” near or on top of the serial # decal.

13) Replace yellow “NG” label with red “ULPG” label.

HI/LO pressure regulator

2

15

10/13/11

INSTALLATION

PTO30CFT -COFFEE TABLE LEG INSTALLATION

It is required the coffee table unit be used with the legs and decorative glass surround guard. This is a safety measure to ensure protection. Please ensure the legs and glass guard is permanently installed as per instructions.

3. Install each leg from the bottom up with supplied bolt, in the same location rubber foot was removed from.

Repeat on all four corners. Ensure holes all aligned.

1. Lift each corner of the coffee table and remove adjustable rubber foot from each corner.

2. Attach the rubber feet removed from Step 1 to the bottom of each leg.

4. Take the supplied sheet metal screw and fasten each leg with one screw from the inside of table screwing downwards into the leg. Repeat all four corners.

16

Ensure hole is lined up.

Regency Plateau™ Series Outdoor Gas Fireplace

NOTE: Max tank size 11lb or 4.5kg.

LP TANK INSTALLATION - PTO30CFT ONLY

1) Remove end panel (opposite end of switch panel),.

INSTALLATION

2) Remove long side panel (left panel if facing ON/OFF switch end), to access the 3/8" fitting to the gas control.

5) Connect the LP regulator quick connect to the tank.

3) Loosen butterfly bolt to allow LP tank to be seated on the holder.

4) Seat tank on tray and tighten butterfly bolt to secure tank to tray.

Gas connection

@ tank

7) Check all gas connections (both valve train & LP tank) under normal operating pressure, for leaks, with soapy water.

NOTE: If soap bubbles, this would indicate a gas leak.

NOTE: Inspect hoses before each use and replace if evidence of excessive abrasion.

IMPORTANT:

PTO30 CFT (Coffee table only)

To avoid tank pressure regulator freezing - when using an 11LB or 4.5KG

LP tank, it is recommended the appliance is run on low (turned down 30%).

WARNING!

When using a LP tank - a minimum 1”(25mm) gap at all times, between the floor and base of unit.

(Refer to owners manual)

must be maintained

919-031

Regency Plateau™ Series Outdoor Gas Fireplace

Part #: 919-031

Size: 5” W x .77” H (File at 100%)

Color: Black font on silver background

Warning= black background - silver font

Material: Matte Silver DPM

17

INSTALLATION

LP TANK INSTALLATION

PTO30IST/PTO30CKT ONLY

NOTE: Max tank size 20lb or 9kg.

1) Remove end panel (opposite end of switch panel).

2) Slide out LP gas tank by pulling from handle on slide out tray.

LP TANK REMOVAL

1) Remove end panel (opposite end of switch panel).

3) Undo butterfly bolt to allow LP tank to be seated on the holder.

4) Place LP tank onto slide out try and screw in butterfly bolt to secure tank.

2) Ensure tank is fully closed. Disconnect gas line.

3) Slide out LP gas tank by pulling from handle on slide out tray.

NOTE: DO NOT SLIDE OUT TANK BY GRASPING FROM TOP OF TANK.

Butterfly bolt

5) Push tank in from the bottom.

DO NOT PUSH IN FROM THE TOP OF THE TANK.

6) Connect the LP regulator quick connect to the tank

7) Check all gas connections (both valve train & propane tank) under normal operating pressure, for leaks, with soapy water.

NOTE: If soap bubbles, this would indicate a gas leak.

Slide out handle

4) Undo butterfly bolt to release tank.

5) Refill tank and reinstall by reversing steps.

Gas connection

@ tank

18

WARNING!

When using a LP tank - a minimum 1”(25mm) gap at all times, between the floor and base of unit.

(Refer to owners manual)

must be maintained

919-031

Butterfly bolt

Regency Plateau™ Series Outdoor Gas Fireplace

Part #: 919-031

Size: 5” W x .77” H (File at 100%)

Color: Black font on silver background

Warning= black background - silver font

Material: Matte Silver DPM

SWITCH CONNECTION

1) Remove the end panel (side with switch assembly mounted on it) from unit.

INSTALLATION

BATTERY INSTALL

1) Remove left side (with switch assembly) end panel from unit.

2) Pull down battery compartment - located below the DFC panel.

2) Connect 2 wires to the switch.

3) Replace panel.

3) Install 4 - AA batteries and reverse steps.

Battery compartment

19

Regency Plateau™ Series Outdoor Gas Fireplace

INSTALLATION

Plateau series

Before installation,stainless steel must be handled and cleaned as per instructions noted below: stainless steel table top

• Stainless table top must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time.

Claims for damage after installation will not receive consideration.

To protect the finish during installation and handling - cotton gloves Must be worn at all times while handling the panels (even when

•Stainless table top will discolor a little during normal operation.

This is normal and should not be considered a defect.

*

All hand and finger marks

Must be cleaned off with a soft cloth and a stainless steel cleaner. Most stainless steel cleaners leave a film/ residue on the surface of the panels. Use an ammonia based cleaner (ie. glass cleaner) to remove this film before applying heat to the unit.

Not protected by product warranty.

6) Secure table to unit from underside, with 4 screws in locations shown below.

NOTE: These instructions apply to both the stainless steel and sunset bronze table tops.

NOTE: Coffee table unit shown below, instructions also apply to built-in burner.

Two brackets need to be installed before installing the Table Top.

1) Remove end panel by pulling off.

7) Place end caps over pilot and opposite end to complete installation.

2) Install Table Top bracket with 3 screws to unit as shown below.

End Caps

8) To remove - reverse steps 7-5.

3) Replace side panel.

4) Repeat Step 1 and 2 on other side.

5) Place Table Top on Unit.

20

919-112a

1

Final Install

Regency Plateau™ Series Outdoor Gas Fireplace

01/12/12

10

1

1

8

6

Table Top Components.

Tiles

Tiles (small inner)

Filler Brackets.

Table Top Frame

Inner frame

NOTE: TAKE CARE WHEN HANDLING AND INSTALLING TILES.

TILES TO FREE FLOAT _ DO NOT GLUE TILES TO TABLE TOP.

1) Install the end caps (found in the manual pack) at each end and secure with 2 phillips screws found in manual pack.

5) Install tiles - starting with 4 corner tiles.

Note: Correct position of fi ller brackets.

6) With 4 corner tiles are in place - install center tiles.

2) Place table top frame on top of unit - fi nished edge with return face up.

3) Line up holes from table top frame with holes on unit - secure with 2 screws at each end - locations shown below

7) Install - 4 smaller inner tiles. Install 2 end small inner tiles to complete tile installation.

4) Place the 10 fi ller brackets on the table top as shown - before installing tiles.

NOTE: Filler brackets are used to fi ll the gaps between each tile.

Install small inner end tiles last

8) With all tiles installed - install inner frame to fi nish installation.

1

01/16/12

21

INSTALLATION

GLASS CRYSTALS OR OPTIONAL CERAMIC SPA / VOLCANIC STONES

GLASS CRYSTAL INSTALLATION

Evenly spread the Glass Crystals or optional Ceramic Spa Stones over the burner. Ensure the crystals (or stones) do not overlap too much as this will effect the fl ame pattern.

IMPORTANT NOTE:

Only the supplied approved Glass Crystals and Ceramic Spa are to be used with these fi replaces. Use of any other type of glass crystals or stones can alter the unit's performance, any damage caused by the use of any unapproved glass or stones will not be covered under warranty.

When using Ceramic Spa DO NOT cover burner ports or pilot light that lead to pilot fl ame. Ensure the crystals or stones do not overlap excessively as this will effect the fl ame pattern.

Unit

HZ54E / HZ54EPV

*Glass Crystals

3 lbs

HZ42 / HZ42E / HZ40E 2 lbs

HZ42ST / HZ42STE

HZ42STEPV

2 lbs

BURNER PACKAGES

Ceramic Spa Stones

1 lb Glass + 2 packages (140 spa stones)

1 lb Glass + 1 package (70 spa stones)

1 lb Glass + 1 package (70 spa stones)

HZ30E **

HZI234E ***

1 lb

3/4 lb

HZI390E/ HZI390EB * 7 lbs [4 lbs burner + 3 lbs fi rebox]

HZI540EB * 8 lbs [4 lbs burner + 4 lbs fi rebox]

HZO42/HZO42 (AUS) 3 lbs

L676S

P33S/P33SE ****

1 lb

1 lbs

PTO30 */ Plateau Series 10 lbs

PTO60* 20 lbs

U32S / U32SE 1 lb

1 lb Glass + 1 package (70 spa stones)**

3/4 lb Glass + 1 package 70 spa stones)***

2 lb Glass + 1 package (70 spa stones)

2 lb Glass + 1 package (70 spa stones)

Not Approved

1 package = (70 spa stones)

1 package = (70 spa stones)****

Not Approved

Not Approved

1 package = (70 spa stones)

E33S 1 lb 1 package = (70 spa stones)

NOTE: * Glass Crystals are available in 1lb and 5lb bags. All units come standard with Cobalt Blue glass crystals except:

* HZO42 comes with Copper glass crystals.

* HZI390E, HZI390EB, HZI540EB, PTO30, PTO60 & Plateau Series do NOT include glass crystals with units. Must purchase separately.

• 1 Ceramic Spa stone package contains 70 stones.

** Recommended - use only 40 of the 70 ceramic stones on the HZ30E burner.

*** Recommended - use only 24 of the 70 ceramic stones on the HZI234E burner.

**** Recommended - use only 50 of the 70 ceramic stones on the P33S/P33SE burner.

Glass Crystals shown on Burner

For Units HZ54E, HZ54EPV, HZ42ST, HZ42STE, HZ42STEPV,

HZI234E, HZ42E, HZ42, HZ40E, HZ30E,

HZO42, HZO42 (AUS) PTO30, PTO60 Plateau Series only

Optional Ceramic Spa Stones + Glass Crystals shown on burner.

For Units HZ54E, HZ54EPV, HZ42ST, HZ42STE, HZ42STEPV,

HZI234E, HZ42, HZ42E, HZ40E, HZ30E only

Glass Crystals shown on Burner

For units P33S, P33SE, L676S, U32S, U32SE, E33S only

Optional Ceramic Spa Stones shown on burner.

For units P33S,P33SE L676S, U32S, U32SE, E33S only

22

918-753k

Glass Crystals shown on Burner and Firebox Floor

For Units HZI390E, HZI390EB, HZI540EB only

1 10/11/11

Regency Plateau™ Series Outdoor Gas Fireplace

INSTALLATION

OPTIONAL VOLCANIC STONES INSTALLATION ON BURNER

Evenly spread the glass crystals and volcanic stones over the burner. Ensure the stones do not overlap too much as this will effect the flame pattern.

IMPORTANT NOTE:

Only the supplied approved Volcanic Stones are to be used with these fireplaces. Use of any other type of stones can alter the unit's performance, any damage caused by the use of any unapproved glass or stones will not be covered under warranty.

When using Volcanic Stones DO NOT cover burner ports or pilot light that lead to pilot flame. Ensure the stones do not overlap excessively as this will effect the flame pattern.

Unit

HZO42/HZO42 (AUS)

OUTDOOR VOLCANIC STONE BURNER PACKAGES

Volcanic Stones

Ivory/Tan

35 stones w/3lbs glass

PTO30 */ Plateau® Series 50 stones w/5lbs glass

Volcanic Stones

35 volcanic stones w/3lbs glass

50 volcanic stones w/5lbs glass

Slate/Grey

NOTE: * Basalt Volcanic stones are measured by weight not quantity. Each bag contains 15lbs of stones, however the exact quantity and size will vary.

Size varies between 2" - 3".

Volcanic Stones + Glass Crystals

For the PTO30

& Plateau® Series only

Volcanic Stones Ivory /Tan + Glass Crystals

For the HZO42 & HZO42AUS only

Volcanic Stones Slate /Grey + Glass Crystals

For the HZO42 & HZO42AUS only

23

Regency Plateau™ Series Outdoor Gas Fireplace

INSTALLATION

OUTDOOR SERIES

GLASS SURROUND INSTALLATION

OPTIONAL GLASS SURROUND/WINDSHIELD INSTALLATION

FOR PROTECTION OF YOUNG CHILDREN OR THE INFIRM , A SECONDARY GUARD IS REQUIRED.

4 Piece Glass Surround

PTO 30-1

Part No. 376-932

Overall Dimensions: 37-15/16" long x 12-13/16" wide x 5-5/16" high

PTO60-1

Part No. 377-955

Overall Dimensions: 68" long x 12-13/16" wide x 5-5/16" high

1. Remove metal fasteners from the corner brackets.

2. Assemble the 4 pieces of the glass surround/windshield and fasten together with 4 corner top brackets and supplied nylon fasteners as shown below.

4b. Use supplied spacer tool to determine where the bottom bracket should be placed and secured.

Bottom Bracket

Spacer tool

Top Bracket

Nylon fasteners

3. Using a fl at screwdriver, secure 4 top corner brackets with nylon fasteners in each corner, bracket should be fl ush with the top of glass as shown below.

5. Secure bottom corner brackets with nylon fasteners in each corner.

6. Flip the glass back over and place on a soft surface. The glass is now right side up. The glass should be raised up 1/2" in bracket as shown below.

Insert nylon fastener here.

Nylon fasteners

1/2"

4a. After the 4 top brackets are installed - fl ip over and place on a soft surface, to install the 4 bottom brackets.

7. Place assembled glass surround/windshield on table top - ensure glass is centered on the table top. Once in correct position, lift up one end, apply double sided tape that has been cut to size, to the bottom of the brackets. Repeat process on other end. Press down fi rmly from to secure glass surround/windshield in position. Use care not to scratch surfaces.

24

919-037

1

Regency Plateau™ Series Outdoor Gas Fireplace

10/30/14

INSTALLATION

RISER INSTALLATION

(TO CONVERT ISLAND INTO COCKTAIL TABLE)

A riser may be installed at the base of the island table to convert it into a cocktail table.

5) Install the 4 adjustable rubber feet into the bottom of the island riser.

Seat all the way in and hand tighten.

1) If the unit is already assembled - remove the glass surround and table top.

2) Remove the two end panels and LP tank - if installed (see LP tank remove section in installation manual). If the unit is connected to a natural gas line, disconnect the gas.

3) Remove the end panels and long side panels, place on a clean soft surface.

6) Place the island unit frame on top of the riser - lining up the screw holes and ensure the drain tube is through the riser drain hole.

4) Remove the 4 adjustable rubber feet form the bottom of the island unit and transfer to the bottom of the riser.

7) If using unit with a natural gas connection, position riser with gas line knockouts over gas supply connection - unless using the LP tank.

On the riser, remove panels by grasping bottom and lift backwards, place on a soft clean surface.

Knockouts

25

Regency Plateau™ Series Outdoor Gas Fireplace

INSTALLATION

5) Install 12 screws in locations shown below to secure island frame to riser base.

5) Reinstall LP tank and reconnect or reconnect NG gas line.

Reinstall panels, table top and glass surround and glass crystals to complete installation.

26

Regency Plateau™ Series Outdoor Gas Fireplace

PLATEAU

®

TABLE COVER INSTALLATIONS

INSTALLATION

DINING LEAF

For all units:

1) Place the dining leaf cover over the burner of the unit when not in use.

GLASS SURROUND COVER

For all units with glass surround installed:

1) Place the weather cover over the glass surround when not in use.

WEATHER COVER

For all units:

1) Place the weather cover over the entire table - when not in use.

CAUTION:

Never start the unit with the cover on.

Let the unit cool before installing the cover.

Turn off gas supply to unit before installing cover.

27

Regency Plateau™ Series Outdoor Gas Fireplace

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

1) Read and understand these instructions before operating this appliance.

2) Check to see that all wiring is correct and enclosed to prevent possible shock.

FIRST FIRE

The first fire in your decorative gas appliance is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your decorative gas appliance for at least one (1) hour the first time you use it.

3) Check to ensure there are no gas leaks.

When first operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing.

4) Check all hoses and connections.

5) The unit should never be turned off, and on again without a minimum of a 60 second wait.

The glass surround may require cleaning after the unit has cooled down.

DO NOT ATTEMPT TO CLEAN THE

GLASS WHILE IT IS HOT.

LIGHTING PROCEDURE

1) Turn on ON/OFF switch.

2) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.

3) The unit will turn on.

Note: The first try for ignition will last approximately

60 seconds. If there is no flame ignition (rectification) the board will stop sparking for approximately 35 seconds. After wait time , the board will start second try for ignition by sparking for approximately 60 seconds . If there is still no positive ignition the board will go into lock out.

INDOOR STORAGE OF

CYLINDERS

1) There is no limitation on the storage of appliance indoors provided that the cylinder is removed from the appliance.

2) Storage of an appliance indoors with the cylinder attached is only permitted if the size of the cylinder complies with AS/NZS 1596: otherwise cylinder must be stored outdoors in a well ventilated area.

The system will need to be reset as follows:

a) Turn the system off using ON/OFF switch.

b) After approximately 2 seconds turn on ON/

OFF switch.

c) Unit will repeat step 2.

SHUTDOWN

PROCEDURE

1) Turn ON/OFF switch.

2) If service is to be performed - you must disconnect the battery pack.

WARNINGS/

IDENTIFICATION FOR

LEAKS

1) Certain combustible materials under or near the appliance will be subject to radiant heat and could be seriously damaged.

2) Inspect all hose assemblies before each use.

3) Check all hose assemblies for wear. Replace if required.

4) Check all connections with soap and water, clean after as some detergents are corrosive.

5) Check all connection, fitting, hoses prior to each use.

Regency Plateau™ Series Outdoor Gas Fireplace

COPY OF LIGHTING PLATE INSTRUCTIONS

The lighting plate is located on the underside of the front access panel in the unit.

Part #: 918-628

Rev: B

Colours: Black on Grey, except

for parts indicated as being

Red.

Size: 100%

w- 5.16"

h- 9.97"

July 17/09: Added french

Feb. 18/10: Revised instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or

Natural Gas and Propane Installation Codes, CSA B149.1.

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or gas supplier.

AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.

Une installation, d'ajustement, de modifi cation, de service ou d'entretien peut provoquer des blessures ou des dommages matériels. Reportez-vous au manuel du propriétaire de l'information fournie avec cet appareil. Pour obtenir de l'aide ou des informations supplémentaires consulter un installateur qualifi é, une agence de service ou fournisseur de gaz.

A) This appliance is equipped with an ignition device which automatically lights the pilot.

Do not try to light the pilot by hand.

B) BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the fl oor

because some gas is heavier than air and will settle on the fl oor.

WHAT TO DO IF YOU SMELL GAS

- Do not try to light any appliance.

- Do not touch any electric switch, do not use any phone in your building.

- Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

- If you cannot reach your gas supplier, call the fi re department.

C) Do not use this appliance if any part has been under water. Immediately call a qualifi ed service

technician to inspect the appliance and replace any part of the control system and any

gas control which has been underwater.

A) Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse.

Ne tentez pas d’allumer la veilleuse manuellement.

B) AVANT DE FAIRE FONCTIONNER, renifl ez tout autour de l’appareil pour déceler une odeur

de gaz. Renifl ez près du plancher, car certains gaz sont pluslourds que l’air et peuvent

s’accumuler au niveau du sol.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

• Ne pas tenter d’allumer d’appareil

• Ne touchez à aucun interrupteur; ne pas vous servir des téléphones se trouvant dans le

bâtiment.

• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les

instructions du fournisseur.

• Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies

C) N’utilisez pas cet appareil s’il a été plongé dansl’eau, même partiellement. Faites inspecter l’appareil par un technicien qualifi é et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.

CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface temperatures keep children, clothing and furniture, gasoline and other liquids having fl ammable vapors away. Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

LIGHTING INSTRUCTIONS

1) Turn on ON/OFF switch

2) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.

3) The unit will turn on.

Note: The fi rst attempt to ignition will last approximately 60 seconds. If there is no fl ame ignition (rectifi cation) the board will stop sparking for approximately 35 seconds. After this wait time, the board will start a second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the second attempt the board will go into lock out.

The system will need to be reset as follows (after going into lock out mode): a) Wait 5 minutes - turn the system off using ON/OFF switch. b) After approximately 2 seconds turn on ON/OFF switch or press ON/OFF button if using optional remote.

c) Unit will repeat step 2.

1) Appuyez le bouton ON / OFF

2) Attendre 4 secondes. Le système d’allumage produira des étincelles pendant 60 secondes afi n d’amorcer le brûleur principal.

3) Les fl ammes s’allumeront.

Remarque : Au premier allumage, le système tente d’allumer les fl ammes pendant 60 secondes. Si l’essai est infructueux, le système fait une pause de 35 secondes. C’est ce qu'on appelle l'étape de rectifi cation. Ce délai

écoulé, le système tente à nouveau d'allumer les fl ammes en produisant des étincelles pendant 60 secondes.

Si les fl ammes ne s’allument toujours pas, le système se met en mode verrouillage.

Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :

a) Attendre 5 minutes et éteindre l’appareil en réglant l’interrupteur à la position « OFF »;

b) Attendre 2 secondes et rallumer le système à l’aide de l’interrupteur ou de la télécommande.

c) L'unité répétera l'étape 2.

TO TURN OFF GAS APPLIANCE

1) Turn off ON/OFF switch

2) If service is to be performed - you must disconnect power to the unit, from the battery pack, refer to manual.

1) Appuyez sur le bouton ON / OFF

2) Si le service est effectuée, vous devez débrancher l'appareil, du bloc-piles, voir le manuel d'instruction pour plus de détails.

DO NOT REMOVE THIS INSTRUCTION PLATE

918-628b

Regency Plateau™ Series Outdoor Gas Fireplace

MAINTENANCE

MAINTENANCE INSTRUCTIONS

1) Always turn off the gas valve and unplug the batteries before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.

2) Clean off leaves etc. before burning.

3) Clean appliance with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a outdoor decorative gas appliance glass cleaner.

4) Hand and finger marks should be cleaned off with a soft cloth and a stainless steel cleaner. Most stainless steel cleaners leave a film/

residue on the surface of the panels. Use an ammonia based cleaner (ie. glass cleaner) to remove this film before applying heat to the unit.

Failure to do this will result in burn stains on panels which you will be unable to remove.

5) Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are steady; not lifting or floating. If there is a problem, call a qualified service person.

6) The appliance must be inspected before use, and at least annually, by a qualified field service person, to ensure that the flow of combustion and ventilation air is not obstructed.

7) Do not use this appliance if the valve and/or electronic components have been or are submerged under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. This is not covered under the terms of the warranty policy.

8) Verify operation after servicing.

30

Regency Plateau™ Series Outdoor Gas Fireplace

SWITCH REPLACEMENT

1) Remove the end panel (side with switch assembly mounted on it) from unit.

MAINTENANCE

2) Remove 2 wire from the switch.

3) Remove 2 screws from switch cover to release switch.

4) Replace switch and reverse steps.

Regency Plateau™ Series Outdoor Gas Fireplace

31

MAINTENANCE

VALVE ASSEMBLY REPLACEMENT

Turn the unit off and allow to cool to room temperature.

1) Remove burner buy removing 6 screws in locations shown below.

8) Manuover valve assembly up and out.

2) Slide the burner to the left and lift out.

3) Turn off gas supply and remove flex connection at valve.

4) Remove orange EV1 wire connected to the gas valve.

5) Remove green EV2 wire connected to the gas valve.

6) Remove HI/LO extension knob.

Hi/Lo

Extension

EV2

EV1 ground

Flame sensor

7) Remove 10 screws in locations shown below to remove valve tray.

9) Replace gasket if required.

10) Replace with new valve assembly.

11) Install Hi/Lo extension knob removed in step 6.

12) Reverse step 6-1 to reinstall.

32

Regency Plateau™ Series Outdoor Gas Fireplace

MAINTENANCE

DIGITAL FIREPLACE CONTROL REPLACEMENT

1) Remove left side (with switch assembly) end panel from unit.

4) Disconnect spark electrode wire.

Disconnect flame sensor (red)

Disconnect ground.

Disconnect wire harness.

2) Remove two screws to remove valve cover panel in locations shown below.

Flame sensor

Spark Electrode Ground

5) Remove 4 screws to remove DFC box.

Wire harness

6) Replace with new DFC box and reverse steps 5-1.

BATTERY REPLACEMENT

1) Remove left side (with switch assembly) end panel from unit.

2) Pull down battery compartment - located below the DFC panel.

3) Remove two screws to swing down DFC box.

3) Replace 4 - AA batteries and reverse steps.

Battery compartment

Battery pack

33

Regency Plateau™ Series Outdoor Gas Fireplace

PARTS LIST

1

2

Part # Description

376-526 Burner Assembly LP/NG

911-006 Pilot Assembly - NG

911-007 Pilot Assembly - LP

376-574/P Valve Assembly - NG

376-574/P Valve Assembly - LP

7

*

*

4

6

911-004 Valve Only - NG

3

911-005 Valve Only - LP

904-951 Orifice #25 - NG

904-655 Orifice #45 - LP

377-900

377-902

Table top frame

Tile set - Slate

377-903 Tile set - Brown

377-080 Inner frame

377-523 Coffee table top

Not Shown

PARTS

Part #

946-775

946-776

946-777

946-778

8

9

376-932

940-374/P

940-375/P

376-027

904-952

911-012

326-930

10 376-522

Description

*Fireglass crystals - Blk

*Fireglass crystals - Copper

*Fireglass crystals -Starfire

*Fireglass crystals - Colbalt Blue

*Glass crystals in 5lb bags - 2 required

Glass Surround

Tempered Glass (LG)

Tempered Glass (SM)

Glass connectors

Nylon fastner

Ignition Board

Log Set

Island riser

919-065 Manual

8

9

5

2

1

3

34

7

4

10

Regency Plateau™ Series Outdoor Gas Fireplace

WARRANTY

Regency

®

Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency® is pleased to extend this limited lifetime warranty to the original purchaser of a Regency

®

Product. Regency

®

will repair or replace goods free of charge in the event of defects arising from faulty materials or workmanship in accordance with the warranty terms in relation to Definitions, Warranty

Conditions and Exclusions stated in this document.

The benefits to the consumer given by this warranty are in addition to all other rights and remedies of the consumer under a law in relation to the goods or services to which the warranty relates.

Our goods come with the guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

The Warranty: Lifetime

Covered under the agreement are the following components: The combustion chamber, heat exchanger, burner tubes/pans, logs, glass crystals, ceramic spa stones, pebbles, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime Warranty for five (5) years for parts and labour and parts only thereafter.

External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and labour for one (1) year from the date of purchase and parts only thereafter.

Regency Fireplace Products is not liable for freight or labour on any gas appliance replaced in the field.

Special Finishes - One year on stainless steel panels, nickel overlays, nickel faceplates, brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating and cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, ie. finger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.

Electrical components such as fans, switches, ignition modules, wiring, thermodiscs, remote control, thermopiles, thermocouples and gas valves are covered for one year for parts and labour from the date of purchase.

The warranty on brass parts is for one year, no labour. The brass is not warranted against tarnishing.

Repair/replacement parts purchased by the consumer from Regency ® after the original coverage has expired on the unit will carry a 90 day warranty valid with a receipt only. Any item shown to be defective will be repaired or replaced at our discretion. No labour coverage is included with these parts.

Conditions:

All installations must be performed by a qualified gas fitter and installed according to all applicable local and national codes. Also, all service work must be carried out by a qualified gas service person provided by the selling dealer. It is the responsibility of the installer to ensure that the appliance is firing as per rating plate. Any part or parts of this unit which in our judgement show evidence of such defect will be repaired or replaced at Regency

®

's option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested. In areas where there is not an approved service agent or the closest approved service agent is situated more than thirty (30) kilometres from the installation, Regency is not obliged to arrange warranty repairs and travel and/or additional labour charges will apply.

Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible. Any chips must be reported and inspected by an authorised dealer within three days of installation. Reported damage after this time will be subject to rejection.

It is the general practice of Regency ® evaluated fro manufacturer defect.

to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to Regency and

At all time Regency reserves the right to inspect product in the field which is claimed to be defective.

All claims must be submitted to Regency ® by authorised selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:

This limited Lifetime Warranty does not extend to or include paint, door or glass gasket or trim. It does not cover installation and operational related problems such as over-firing, down drafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate flueing or ventilation, excessive offsets, negative air pressures caused by insufficient make up air, mechanical systems such as furnaces, fans, clothes dryers etc.

Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.

Regency ® will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Performance problems due to operator error will not be covered by this warranty policy.

The warranty does not extend to any part or parts which show evidence of misuse or abuse, neglect, accident, lack of maintenance, or improper installation.

Products made by other manufacturers and used in conjunction with the operation of this appliance without authorisation from Regency

®

, may nullify your warranty on this product.

Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.

SUBJECT TO CHANGE.

DISTRIBUTORS: Western Australia

Air Group Australia

28-30 Division St.

Welshpool, WA 6106

08 9350 2200

Eastern Australia

Fireplace Products Australia PTY. Ltd.

1-3 Conquest Way

Hallam, VIC 3803

03 9799 7277

NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION

INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY

A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES.

35

Regency Plateau™ Series Outdoor Gas Fireplace

Register your Regency

®

warranty online www.regency-fire.com.au

Reasons to register your product online today!

• View and modify a list of all your registered products.

• Request automatic email notification of new product updates.

• Stay informed about the current promotions, events, and special offers on related products.

• Help assure you get the most out of your warranty.

• Eliminate confusion and frustration if warranty** service is required in the future.

** Proof of purchase required at time of warranty request.

Installer: Please complete the following information

Dealer Name & Address: ______________________________________________

___________________________________________________________________

Installer: ___________________________________________________________

Phone #: ___________________________________________________________

Date Installed: ______________________________________________________

Serial No.: __________________________________________________________

Regency is a registered trademarks of FPI Fireplace Products International Ltd.

© Copyright 2015, FPI Fireplace Products International Ltd. All rights reserved.

advertisement

Related manuals