Leica LMD6000 laser microdissection microscope, CTR6500 microscope Operation Protocol
PDF
Dokumentas
Reklama
Reklama
Goldberg Lab USING LEICA AS LASER MICRODISSECTION (LMD6000) MICROSCOPE Written By Jungim Hur Digital Video Camera Eyepieces Laser module Laser safety UV shield Specimen holder Smart move control LEICA CTR6500 electronics box 1. Mains switch 2. Pilot indicator Front side of the laser box 1. Key-operated switch 2. Switch for external trigger 3. Status LED: Operating status of laser 4. Push-button: Laser on/off 5. Status LED: Laser active/inactive 6. Service plug 1 Goldberg Lab 6. Description and assembly of the components • Place the specimen holder (fig. 8) onto the stage you are using and fasten it with the two Leica LMD6000 Operation Protocol screws 6.2 Condenser You can use either a motorized or a manual condenser. Both are equipped with condenser head S28. 1) Clean the LMD station including slide holder, PCR tube tray sub-stage holder, the 3-D • Screw the condenser head into the 10 Collection device with caps damped with DEPC treated H2O (500 µl SatelliteFig.controls and Fig. keyboard with Kimwipes condenser. 8 Removable specimen holder 1 ml ForH motor stage a 3-fold holder forin scanning stage DEPC solution 500 2O). b holder for motor stage 2 For scanning stage • Using the condenser height adjuster (10.4), turn the condenser holder (10.1) completelyThe name of downwards. corresponds • a 1 • the specimen (“Specimen ID“ to the name in the “Change Specimen“ dialog which is opened with the Unscrew the clamping screw for the condenser (10.3) far enough so that the“Unload“ key after a change of specimen. A condenser can be inserted from the front. data sheet is created in the "LMDDB" archive for From the front, insert the condenser into theeach specimen name. 2 condenser holder as far as it will go. On the underside of the condenser, there is an orientation pin, which must be located in the guiding notch (9.1). 15 2) Turn on power to: • Pull the condenser’s clamping screw (10.3) so that the condenser in place.self diagnostic tests, stage a. CTR-MIC control box (microscope will gois locked through will move; requires about 30 seconds). b. CPU/monitor the usual way by the on button on the computer. b c. Laser (with key). During warm-up, the laser power box will display one green Fig. 10 Condenser holder light (left). When the second green 1 Condenser holderlight (right) comes on, the laser is ready. 2 Condenser centering Touch the red button between the two green lights on the laser power supply to Fig. 9 Condenser holder 3 Clamping screw for condenser 1activate Guiding notch the laser. Now there4 will Condenser adjuster beheight one green light (left) and one red light (right). The laser is ready to fire. Requires about 5 minutes. If you want to take a break more than 5 minute, then press red button and the laser box will display two green lights. It will be 1 in the “stand-by” mode and will be reactivated by 1pressing the red button between the two green lights. 3) Allow the microscope to fully initialize the stage2 before starting the LMD application 3 4 software. 17 4) Check to be sure the Laser Safety Shield is properly in place. Laser will not fire without the laser safety shield in place. 5) Activate the LMD software from the Desktop by double clicking on the LMD icon. Click on the “LOAD” slide (left) button in the software menu. Slide holder will move forward; pull the slide holder forward and out of the microscope stage. Insert the special foil membrane slides with mounted tissue sections into the slide holder (be sure to have the proper orientation of the specimen facing down in the microscope). Return the slide holder back into the microscope stage by sliding the holder along the slide rails until it snaps into place. Click the “Continue” button on the dialog box to take the slide holder into the microscope. Create Specimen Overview images by clicking “Options/Specimen Overview“. Use lower magnification (4X-10X) and define scanning are. Then, save scanned overview image. 2 Goldberg Lab 6) Click the “Unload” Collector (right) button in the menu bar to unload the collection device (moves forward), Load PCR tubes with caps into the collection device. Inserting the cap into the holder 1. Lid of the cap 2. Holder For RNA isolation from LCM samples, place Extraction buffer (20-30 µl) from PicoPure RNA Isolation kit into the caps (Avoid bubbles when you place buffer into the caps). Return the collector to the sub-stage holder and click OK to return the collector into the sub-stage of the microscope. Select a cap to collect samples by clicking the corresponding circular red marking at the bottom left of the work window. The selected cap turns green. While collecting the cell types that you are interested, the buffer added into the tube cap might be dried. You may add 10 µl of H2O into the tube cap after 1-1.5 hour of cutting if the light is getting dimmer because the buffer is dried and should not collect samples more than 2.5 hours into sample cap. 7) The 3-D Satellite controls all basic remote functions of the microscope. a. These include motorized X and Y stage movements and Z microscope focus functions. b. The buttons on the right side switch between coarse or fine focus and stage motion. c. The buttons on the left side control the up and down magnification by changing the objectives on the nosepiece, one position at a time. Smartmove control 1. Movement in x direction 2. Movement in y direction 3. Setting the focus 4. Individual knob height position 3 Goldberg Lab 8) Focus the specimen with a low power objective and adjust for proper illumination levels and binocular phototube prism setting for an on screen image as necessary. Move the stage to bring the area or cells of interest into the center of the field of view. Switch to a higher power objective by touching your selection on the front touch screen of the microscope, for better detail and identification of the cells of interest for cutting, and adjust focus and light level if necessary. If obtained sample image is not focused or it is hard to define the cell type that you are interested, you may align condenser adjust. To align condenser, close the field diaphragm all the way (control the field diaphragm on the microscope control dialogue window) and rotate the knob on the condenser until the circle of light is crisp and in focus. Then open up closed field diaphragm and adjust the aperture diaphragm. Refer to Condenser Alignment Protocol provided by Leica microsystem. 9) Perform Laser calibration on set-up before cutting the region of interest. 10) Test different laser settings (power and speed) to obtain optimized condition for the cell types that you are interested. Then, record the setting and proceed. On the right side of the software interface, select the “Draw and Cut” mode. Use the optional touch screen pen to drawn the region of interest (ROI) directly on the monitor or move the mouse cursor to the image area, and click and hold the left mouse button to draw a line or shape on the monitor around the cell or cells of interest. If the drawing is not desirable, remove the line from the shape list. iClick on the “Start Cut” button in the software, or alternately right click and select “Cut”. 4 Goldberg Lab It is recommended to save the image with drawn the region of interest before and after cut. 11) If the laser does not cut properly through the specimen, optimize laser settings in “Laser Control” by adjusting “Power”, and/or “Speed”. Sometimes, laser loses power after few hours of use, then increase laser power and re-draw the line and cut it again. (Refer to suggested laser settings for a “normal” histological tissue sections by clicking “Factory Settings” in the Laser Control window. Also, you can refer to the settings previously used to cut the cells of interest.) 12) Cutting options include: free hand figures with close line option, circle and rectangle figures. 13) Cutting options also include: “Draw and Cut” or “Move and Cut”. If region of interest is not released after cut, re-draw the line and cut again or increase laser power and click “Move and Cut” button to release cut. You can inspect the samples in the cap of collection tube by pressing the "Collector" key in the toolbar. Pressing the "Specimen" key restores the previous cutting position. 14) The “Close Line” feature can simply be checked on or off, but area measurements are only functional with the Close Line activated. 15) Laser Alignment and laser controls settings are specific to each objective and can be saved under “File” and “Save Configuration File As.” By naming this file and saving it to the folder “Profiles,” one is able to recall all laser settings saved during a cutting session. 16) To recall a user specific configuration files, go to “File” and “Restore Configuration File, ” find and activate your specific file. 17) When you finish collecting samples, take out the tube from the collection device by unloading collector. The samples on the tube cap should be collected into the tube by brief spin and stored at -80°C until use. Also, unload slide by clicking on the “LOAD” slide (left) button in the software menu. Pull the slide holder out of the microscope stage and remove slide and store in the slide box. Unload collector device Unload slide holder 5 Goldberg Lab 18) Make sure to record the laser setting and the information of the cell types you have captured, the objective used to capture, the volume of extraction buffer and H2O, the collection tube name and the date of capture. 19) Close LMD Software 20) Shut down Windows (computer) 21) Turn power off to: a. CTR MIC controller box b. Laser (turn key to off position) c. Fluorescence Power Supply (if utilized during your session) d. Monitor Adjustment of CORR objective settings for the L20x, L40x and L63x objective 1) Depending on whether you use the Glass PEN foil slide or Metal PET Frame foil slides or Metal POL Frame foil slides, one must properly set the correction collar of all CORR objectives in order to achieve the best image possible. The wrong correction collar setting will result in a poor or hazy image and a sub-optimal laser cutting. The correction collar settings are dramatically different between the glass PEN foil slides and the metal frame foil slides. Using the settings of one for the other type of slide will not give optimal imaging results. 2) For Glass PEN foil slides, the correction collar setting should be approximately 0.9 while for any Metal frame foil slide, the correction collar setting should be approximately 0.1. However, proper setting should be obtained by observing the image and turning the correction collar until optimum contrast and clarity in the image is achieved. NOTE: Refer to Leica LMD6000 V6.3.1. Quick (Basic Operation) Start Up and comprehensive online “Help” files from the LMD software or consult the LMD printed instruction manual provided with the system. 6 ">
/
Atsisiųsti
Tiesiog draugiškas priminimas. Dokumentą galite peržiūrėti tiesiog čia. Bet svarbiausia, kad mūsų AI jau jį perskaitė. Jis gali paaiškinti sudėtingus dalykus paprastais terminais, atsakyti į jūsų klausimus bet kuria kalba ir padėti greitai naršyti net ilgiausius ar sudėtingiausius dokumentus.
Reklama