Bristol CI-ControlWaveEXP ControlWave I/O Expansion Rack Instruction Manual
PDF
Document
Advertisement
Advertisement
Instruction Manual CI-ControlWaveEXP Aug., 2006 ControlWave (I/O Expansion Rack) www.EmersonProcess.com/Bristol ControlWave EXP IMPORTANT! READ INSTRUCTIONS BEFORE STARTING! Be sure that these instructions are carefully read and understood before any operation is attempted. Improper use of this device in some applications may result in damage or injury. The user is urged to keep this book filed in a convenient location for future reference. These instructions may not cover all details or variations in equipment or cover every possible situation to be met in connection with installation, operation or maintenance. Should problems arise that are not covered sufficiently in the text, the purchaser is advised to contact Bristol for further information. EQUIPMENT APPLICATION WARNING The customer should note that a failure of this instrument or system, for whatever reason, may leave an operating process without protection. Depending upon the application, this could result in possible damage to property or injury to persons. It is suggested that the purchaser review the need for additional backup equipment or provide alternate means of protection such as alarm devices, output limiting, failsafe valves, relief valves, emergency shutoffs, emergency switches, etc. If additional in-formation is required, the purchaser is advised to contact Bristol . RETURNED EQUIPMENT WARNING When returning any equipment to Bristol for repairs or evaluation, please note the following: The party sending such materials is responsible to ensure that the materials returned to Bristol are clean to safe levels, as such levels are defined and/or determined by applicable federal, state and/or local law regulations or codes. Such party agrees to indemnify Bristol and save Bristol harmless from any liability or damage which Bristol may incur or suffer due to such party's failure to so act. ELECTRICAL GROUNDING Metal enclosures and exposed metal parts of electrical instruments must be grounded in accordance with OSHA rules and regulations pertaining to "Design Safety Standards for Electrical Systems," 29 CFR, Part 1910, Subpart S, dated: April 16, 1981 (OSHA rulings are in agreement with the National Electrical Code). The grounding requirement is also applicable to mechanical or pneumatic instruments that include electrically-operated devices such as lights, switches, relays, alarms, or chart drives. EQUIPMENT DAMAGE FROM ELECTROSTATIC DISCHARGE VOLTAGE This product contains sensitive electronic components that can be damaged by exposure to an electrostatic discharge (ESD) voltage. Depending on the magnitude and duration of the ESD, this can result in erratic operation or complete failure of the equipment. Read supplemental document S14006 at the back of this manual for proper care and handling of ESD-sensitive components. Bristol 1100 Buckingham Street, Watertown, CT 06795 Telephone (860) 945-2200 WARRANTY A. Bristol warrants that goods described herein and manufactured by Bristol are free from defects in material and workmanship for one year from the date of shipment unless otherwise agreed to by Bristol in writing. B. Bristol warrants that goods repaired by it pursuant to the warranty are free from defects in material and workmanship for a period to the end of the original warranty or ninety (90) days from the date of delivery of repaired goods, whichever is longer. C. Warranties on goods sold by, but not manufactured by Bristol, are expressly limited to the terms of the warranties given by the manufacturer of such goods. D. All warranties are terminated in the event that the goods or systems or any part thereof are (i) misused, abused or otherwise damaged, (ii) repaired, altered or modified without Bristol's consent, (iii) not installed, maintained and operated in strict compliance with instructions furnished by Bristol, or (iv) worn, injured or damaged from abnormal or abusive use in service time. E. THESE WARRANTIES ARE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED (INCLUDING WITHOUT LIMITATION WARRANTIES AS TO MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE), AND NO WARRANTIES, EXPRESS OR IMPLIED, NOR ANY REPRESENTATIONS, PROMISES, OR STATEMENTS HAVE BEEN MADE BY BRISTOL UNLESS ENDORSED HEREIN IN WRITING. FURTHER, THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. F. No agent of Bristol is authorized to assume any liability for it or to make any written or oral warranties beyond those set forth herein. REMEDIES A. Buyer's sole remedy for breach of any warranty is limited exclusively to repair or replacement without cost to Buyer of any goods or parts found by Seller to be defective if Buyer notifies Bristol in writing of the alleged defect within ten (10) days of discovery of the alleged defect and within the warranty period stated above, and if the Buyer returns such goods to Bristol's Watertown office, unless Bristol's Watertown office designates a different location, transportation prepaid, within thirty (30) days of the sending of such notification and which upon examination by Bristol proves to be defective in material and workmanship. Bristol is not responsible for any costs of removal, dismantling or reinstallation of allegedly defective or defective goods. If a Buyer does not wish to ship the product back to Bristol, the Buyer can arrange to have a Bristol service person come to the site. The Service person's transportation time and expenses will be for the account of the Buyer. However, labor for warranty work during normal working hours is not chargeable. B. Under no circumstances will Bristol be liable for incidental or consequential damages resulting from breach of any agreement relating to items included in this quotation, from use of the information herein or from the purchase or use by Buyer, its em-ployees or other parties of goods sold under said agreement. How to return material for Repair or Exchange Before a product can be returned to Bristol for repair, upgrade, exchange, or to verify proper operation, form (GBU 13.01) must be completed in order to obtain a RA (Return Authorization) number and thus ensure an optimal lead time. Completing the form is very important since the information permits the Bristol Repair Dept. to effectively and efficiently process the repair order. You can easily obtain a RA number by: A. FAX Completing the form (GBU 13.01) and faxing it to (860) 945-3875. A Bristol Repair Dept. representative will return call (or other requested method) with a RA number. B. E-MAIL Accessing the form (GBU 13.01) via the Bristol Web site (www.bristolbabcock.com) and sending it via E-Mail to [email protected]. A Bristol Repair Dept. representative will return E-Mail (or other requested method) with a RA number. C. Mail Mail the form (GBU 13.01) to Bristol Inc. Repair Dept. 1100 Buckingham Street Watertown, CT 06795 A Bristol Repair Dept. representative will return call (or other requested method) with a RA number. D. Phone Calling the Bristol Repair Department at (860) 945-2442. A Bristol Repair Department representative will record a RA number on the form and complete Part I, then send the form to the Customer via fax (or other requested method) for Customer completion of Parts II & III. A copy of the completed Repair Authorization Form with issued RA number should be included with the product being returned. This will allow us to quickly track, repair, and return your product to you. Bristol Inc. Repair Authorization Form (off-line completion) (Providing this information will permit Bristol Inc. to effectively and efficiently process your return. Completion is required to receive optimal lead time. Lack of information may result in increased lead times.) Date___________________ RA #___________________SH_ Standard Repair Practice is as follows: Variations to this is practice may be requested in the “Special Requests” section. • Evaluate / Test / Verify Discrepancy • Repair / Replace / etc. in accordance with this form • Return to Customer Part I Line No.____________ Please be aware of the Non warranty standard charge: • There is a $100 minimum evaluation charge, which is applied to the repair if applicable (√ in “returned” B,C, or D of part III below) Please complete the following information for single unit or multiple unit returns Address No. (office use only) Address No. (office use only) Bill to : Ship to: Purchase Order: Contact Name:____________________________________ Phone: Fax: Part II E-Mail: Please complete Parts II & III for each unit returned Model No./Part No. Description Range/Calibration S/N Reason for return : 1. Failure Upgrade Verify Operation Other Describe the conditions of the failure (Frequency/Intermittent, Physical Damage, Environmental Conditions, Communication, CPU watchdog, etc.) (Attach a separate sheet if necessary) 2. Comm. interface used: 3. What is the Firmware revision? _____________________ Standalone RS-485 Ethernet Other:______________ Modem (PLM (2W or 4W) or SNW) What is the Software &version? Part III If checking “replaced” for any question below, check an alternate option if replacement is not available A. If product is within the warranty time period but is excluded due to Bristol’s warranty clause, would you like the product: repaired returned replaced scrapped? B. If product were found to exceed the warranty period, would you like the product: repaired returned replaced scrapped? C. If product is deemed not repairable would you like your product: returned replaced scrapped? D. If Bristol is unable to verify the discrepancy, would you like the product: returned replaced *see below? * Continue investigating by contacting the customer to learn more about the problem experienced? The person to contact that has the most knowledge of the problem is: ______________________________ phone_____________________ If we are unable to contact this person the backup person is: _________________________ phone_____________________ Special Requests: ____________________________________________________________________________________ ____________________________________________________________________________________________________ Ship prepaid to: Bristol Inc., Repair Dept., 1100 Buckingham Street, Watertown, CT 06795 Phone: 860-945-2442 Fax: 860-945-3875 Form GBU 13.01 Rev. B 04/11/06 Bristol Training GET THE MOST FROM YOUR BRISTOL BABCOCK INSTRUMENT OR SYSTEM • Avoid Delays and problems in getting your system on-line • Minimize installation, start-up and maintenance costs. • Make the most effective use of our hardware and software. • Know your system. As you know, a well-trained staff is essential to your operation. Bristol Inc. offers a full schedule of classes conducted by full-time, professional instructors. Classes are offered throughout the year at three locations: Houston, Orlando and our Watertown, CT headquarters. By participating in our training, your personnel can learn how to install, calibrate, configure, program and maintain any and all Bristol products and realize the full potential of your system. For information or to enroll in any class, contact our training department in Watertown at (860) 945-2343. For Houston classes, you can also contact our Houston office, at (713) 6856200. A Few Words About Bristol Inc. For over 100 years, Bristol® has been providing innovative solutions for the measurement and control industry. Our product lines range from simple analog chart recorders, to sophisticated digital remote process controllers and flow computers, all the way to turnkey SCADA systems. Over the years, we have become a leading supplier to the electronic gas measurement, water purification, and wastewater treatment industries. On off-shore oil platforms, on natural gas pipelines, and maybe even at your local water company, there are Bristol Inc. instruments, controllers, and systems running year-in and year-out to provide accurate and timely data to our customers. Getting Additional Information In addition to the information contained in this manual, you may receive additional assistance in using this product from the following sources: Help Files / Release Notes Many Bristol software products incorporate help screens. In addition, the software typically includes a ‘read me’ release notes file detailing new features in the product, as well as other information which was available too late for inclusion in the manual. Contacting Bristol Inc. Directly Bristol's world headquarters is located at 1100 Buckingham Street, Watertown, Connecticut 06795, U.S.A. Our main phone numbers are: (860) 945-2200 (860) 945-2213 (FAX) Regular office hours are Monday through Friday, 8:00AM to 4:30PM Eastern Time, excluding holidays and scheduled factory shutdowns. During other hours, callers may leave messages using Bristol's voice mail system. Telephone Support - Technical Questions During regular business hours, Bristol's Application Support Group can provide telephone support for your technical questions. For technical questions about TeleFlow products call (860) 945-8604. For technical questions about ControlWave call (860) 945-2394 or (860) 945-2286. For technical questions regarding Bristol’s OpenEnterprise product, call (860) 945-3865 or e-mail: [email protected] For technical questions regarding ACCOL products, OpenBSI Utilities, UOI and all other software except for ControlWave and OpenEnterprise products, call (860) 945-2286. For technical questions about Network 3000 hardware, call (860) 945-2502. You can e-mail the Application Support Group at: [email protected] The Application Support Group maintains an area on our web site for software updates and technical information. Go to: www.bristolbabcock.com/services/techsupport/ For assistance in interfacing Bristol hardware to radios, contact Bristol’s Communication Technology Group in Orlando, FL at (407) 629-9463 or (407) 629-9464. You can e-mail the Communication Technology Group at: [email protected] Telephone Support - Non-Technical Questions, Product Orders, etc. Questions of a non-technical nature (product orders, literature requests, price and delivery information, etc.) should be directed to the nearest sales office (listed on the rear cover of this manual) or to your Bristol-authorized sales representative. Please call the main Bristol Inc. number (860-945-2200) if you are unsure which office covers your particular area. Visit our Site on the World Wide Web For general information about Bristol Inc. and its products, please visit our site on the World Wide Web at: www.bristolbabcock.com Training Courses Bristol’s Training Department offers a wide variety of courses in Bristol hardware and software at our Watertown, Connecticut headquarters, and at selected Bristol regional offices, throughout the year. Contact our Training Department at (860) 945-2343 for course information, enrollment, pricing, and scheduling. CI-ControlWaveEXP ControlWave I/O Expansion Rack TABLE OF CONTENTS SECTION TITLE PAGE # Section 1 - INTRODUCTION 1.1 1.2 1.2.1 1.2.1.1 1.2.1.2 1.2.1.3 1.2.1.4 1.2.1.5 1.2.2 1.2.2.1 1.2.2.2 1.2.2.3 1.2.2.4 1.2.3 1.2.3.1 1.2.4 1.2.5 1.2.5.1 1.2.5.2 1.2.5.3 1.2.5.4 1.2.5.5 GENERAL DESCRIPTION ........................................................................................... 1-1 PHYSICAL DESCRIPTION........................................................................................... 1-3 CPU Module ................................................................................................................... 1-3 CPU Module Connectors ............................................................................................... 1-5 CPU Module Switches .................................................................................................... 1-7 CPU Module System Battery......................................................................................... 1-8 CPU Module LEDs and LCDs ....................................................................................... 1-8 CPU Module Memory Summary.................................................................................... 1-8 Power Supply/Sequencer Module................................................................................... 1-9 PSSM Power Switch SW1 ............................................................................................ 1-12 PSSB Board Fuses ........................................................................................................ 1-12 PSSB Board Connectors ............................................................................................... 1-12 PSSM LEDs .................................................................................................................. 1-12 ControlWaveEXP Backplanes ................................................................................... 1-14 I/O Module Access......................................................................................................... 1-15 ControlWave I/O Expansion Rack Chassis................................................................ 1-16 ControlWaveEXP I/O Modules .................................................................................. 1-17 Analog Input Module .................................................................................................... 1-17 Analog Output Module ................................................................................................. 1-18 Digital Input Module .................................................................................................... 1-18 Digital Output Module ................................................................................................. 1-18 Universal Digital Input Module................................................................................... 1-18 Section 2 - INSTALLATION & OPERATION 2.1 2.2 2.2.1 2.2.2 2.3 2.3.1 2.3.1.1 2.3.2 2.3.3 2.3.3.1 2.3.3.2 2.3.3.3 2.3.3.4 2.3.4 2.3.4.1 2.3.4.2 2.3.4.3 2.3.4.4 INSTALLATION IN HAZARDOUS AREAS................................................................. 2-1 INSTALLATION SITE CONSIDERATIONS ............................................................... 2-3 Temperature & Humidity Limits .................................................................................. 2-3 Vibration Limits ............................................................................................................. 2-3 INSTALLATION/CONFIGURATION........................................................................... 2-3 Mounting the ControlWave I/O Expansion Rack Chassis.......................................... 2-6 ControlWave I/O Expansion Rack Grounding............................................................. 2-6 Power Supply/Sequencer Module (PSSM) Installation ................................................ 2-6 CPU Module Installation ............................................................................................... 2-7 CPU Module Switch Configuration ............................................................................... 2-8 Communication Ports ................................................................................................... 2-10 RS-232 & RS-485 Interfaces ........................................................................................ 2-11 Ethernet Port ................................................................................................................ 2-15 I/O Module Installation & Wiring................................................................................ 2-16 Installation of I/O Modules .......................................................................................... 2-17 Wire Connections.......................................................................................................... 2-21 Shielding and Grounding ............................................................................................. 2-21 Digital Inputs................................................................................................................ 2-21 ControlWaveEXP Contents / 0 - 1 CI-ControlWaveEXP ControlWave I/O Expansion Rack TABLE OF CONTENTS SECTION TITLE PAGE # Section 2 - INSTALLATION (Continued) 2.3.4.4.1 2.3.4.5 2.3.4.5.1 2.3.4.6 2.3.4.6.1 2.3.4.7 2.3.4.7.1 2.3.4.8 2.3.4.8.1 2.3.5 2.3.5.1 2.3.5.2 2.3.5.3 2.3.6 2.3.7 2.4 2.4.1 2.4.2 2.4.2.1 2.4.2.2 2.4.2.3 2.4.3 2.4.4 2.4.4.1 2.4.4.2 2.4.5 Digital Input Configurations........................................................................................ 2-22 Digital Outputs ............................................................................................................. 2-25 Digital Output Configurations..................................................................................... 2-25 Analog Inputs................................................................................................................ 2-28 Analog Input Configurations ....................................................................................... 2-28 Analog Outputs ............................................................................................................. 2-32 Analog Output Configurations..................................................................................... 2-32 Universal Digital Input Modules ................................................................................. 2-35 Universal Digital Input Configurations ...................................................................... 2-35 Power Supply Wiring.................................................................................................... 2-38 Bulk Power Supply Current Requirements ................................................................ 2-38 Power Wiring ................................................................................................................ 2-40 Watchdog Switch & Redundant Unit Wiring.............................................................. 2-41 Installation of the Lithium Backup Battery ............................................................... 2-42 Installation of the Bezel Assembly .............................................................................. 2-43 OPERATIONAL DETAILS .......................................................................................... 2-44 Configuring & Downloading the Application Load..................................................... 2-44 Upgrading ControlWave I/O Expansion Rack Firmware ......................................... 2-44 Using LocalView to Upgrade ControlWaveEXP Firmware ..................................... 2-45 Using Hyperterminal to Upgrade ControlWaveEXP Firmware.............................. 2-49 Remote Upgrade of ControlWaveEXP Firmware ..................................................... 2-52 Operation of the Reset Switch (Button) ...................................................................... 2-53 Module Hot Swapping .................................................................................................. 2-53 I/O Module Hot Swap Removal.................................................................................... 2-53 I/O Module Hot Swap Installation............................................................................... 2-53 Soft Switch Configuration and Communication Ports ............................................... 2-53 Section 3 - SERVICE 3.1 3.2 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 3.2.5.1 3.2.5.2 3.3 3.3.1 3.3.2 3.3.3 3.4 3.4.1 0 - 2 / Contents SERVICE INTRODUCTION ........................................................................................ 3-1 COMPONENT REMOVAL/REPLACEMENT PROCEDURES................................... 3-1 Accessing Modules For Testing...................................................................................... 3-1 Removal/Replacement of the Bezel Assembly............................................................... 3-2 Removal/Replacement of the CPU Module ................................................................... 3-2 Removal/Replacement of the Power Supply/Sequencer Module .................................. 3-2 Module Hot Swapping .................................................................................................... 3-3 I/O Module Hot Swap Removal...................................................................................... 3-3 I/O Module Hot Swap Installation................................................................................. 3-3 TROUBLESHOOTING TIPS......................................................................................... 3-3 Power Supply/Sequencer Module (PSSM) Voltage Checks .......................................... 3-3 LED Checks .................................................................................................................... 3-4 Wiring/Signal Checks ..................................................................................................... 3-9 GENERAL SERVICE NOTES ....................................................................................... 3-9 Extent of Field Repairs................................................................................................... 3-9 ControlWaveEXP CI-ControlWaveEXP ControlWave I/O Expansion Rack TABLE OF CONTENTS SECTION TITLE PAGE # Section 3 - SERVICE (Continued) 3.4.2 3.4.3 3.5 3.5.1 3.5.1.1 3.5.1.2 3.5.1.3 3.5.1.4 3.6 Disconnecting RAM Battery .......................................................................................... 3-9 Port 80 Display POST Checks ....................................................................................... 3-9 WINDIAG DIAGNOSTICS .......................................................................................... 3-12 Diagnostics Using WINDIAG ...................................................................................... 3-14 Communications Diagnostic Port Loop-back Test ...................................................... 3-16 Serial Communications Port External Loop-back Test Procedure ............................ 3-17 Ethernet Diagnostic Port Loop-back Test ................................................................... 3-17 Ethernet Port 1 External Loop-back Test Procedure ................................................. 3-19 CORE UPDUMP........................................................................................................... 3-19 Section 4 - SPECIFICATIONS 4.1 4.2 4.2.1 4.2.2 4.2.3 4.3 4.4 4.5 4.5.1 4.5.2 4.5.3 4.5.4 4.5.5 4.6 4.7 CPU, MEMORY & PROGRAM INTERFACE .............................................................. 4-1 POWER SUPPLY/SEQUENCER MODULE ............................................................... 4-4 Input Power Specs. ......................................................................................................... 4-4 Power Supply Sequencer Specs. .................................................................................... 4-5 Power Supply Connectors............................................................................................... 4-6 BACKPLANE PCB ......................................................................................................... 4-7 COMMUNICATION PORTS ......................................................................................... 4-8 INPUT/OUTPUT MODULE SPECIFICATIONS......................................................... 4-8 Analog Inputs.................................................................................................................. 4-8 Digital Inputs.................................................................................................................. 4-9 Analog Outputs ............................................................................................................... 4-9 Digital Outputs ............................................................................................................. 4-10 Universal Digital Inputs .............................................................................................. 4-11 ENVIRONMENTAL SPECIFICATIONS.................................................................... 4-12 DIMENSIONS .............................................................................................................. 4-12 APPENDICES/SUPPLEMENTAL INSTRUCTION Special Instructions for Class I, Division 2 Hazardous Locations.................Appendix A Open Modbus Interface Information ...............................................................Appendix B MATERIAL SAFETY DATA SHEETS ........................................................... Appendix Z Site Considerations for Equipment Installation, Grounding & Wiring ...........S1400CW Care and Handling of PC Boards and ESD-Sensitive Components ..................... S14006 REFERENCED Bristol CUSTOMER INSTRUCTION MANUALS WINDIAG - Windows Diagnostics for Bristol Controllers ...................................D4041A Open BSI Utilities Manual ...................................................................................... D5081 ControlWave I/O Expansion Rack Quick Setup Guide........................................... D5122 Getting Started with ControlWave Designer.......................................................... D5085 Open BSI Technician Toolkit Manual ..................................................................... D5087 ControlWave Designer Reference Manual .............................................................. D5088 ControlWave Designer Programmer’s Manual ....................................................... D5125 ControlWaveEXP Contents / 0 - 3 BLANK PAGE Section 1 INTRODUCTION 1.1 GENERAL DESCRIPTION ControlWave™ I/O Expansion Racks employ a scalable, modular hardware architecture with a modern and rugged industrial design that is both simple to install and configure. ControlWave™ I/O Expansion Racks have been designed and integrated to provide high performance with low power consumption. Units are available with Backplanes that support up to 2, 4 or 8 I/O modules. Each ControlWave™ I/O Expansion Rack is comprised of a Backplane Board (mounted in the Chassis), a CPU Module, a Power Supply Module and from 1 to 8 I/O modules. The CPU Module utilizes an Intel’s 386EX microprocessor running at 25 MHz. In addition to the microprocessor and control logic, the CPU Board includes a Serial Real Time Clock, an RS-232 communication port (COM1), a communications port that is factory configured with RS-232 or RS-485 hardware (COM2), 1 or 2MB of Static RAM (SRAM), 2 or 4MB of simultaneous Read/Write FLASH, Boot/Downloader in a 512kB FLASH BIOS IC, an I/O Bus Connector, a 10/100baseT Ethernet port, and a PC-104 Bus Expansion Connector. All system modules plug into the Backplane Board (2, 4, or 8 I/O versions available). Each I/O Module provides the circuitry and field interface hardware necessary to interconnect the assigned field I/O circuits. Additionally the CPU Board implements a Port-80 Display consisting of two TI TIL311 Displays that are visible from the front edge of the CPU Module. The Port-80 Display assembly will display POST codes during system boot as well as run time status information. Isolated power is generated and regulated by the Power Supply/Sequencer Module that provides +3.3Vdc, +5Vdc, +12Vdc (optional) and -12Vdc (optional) from a bulk 10.6 to 20 Vdc or 20.7 to 30 Vdc source. ControlWave™ I/O Expansion Racks provide the following key features: • • • • • • • • • Low power consumption Small size (supports panel-mount or 19-inch rack-mount installations) One fixed RS-232 asynchronous serial port (COM1) (PC/AT 9-pin male D-sub connector) One factory configured communications port (COM2) (RS-232 or RS-485) (PC/AT 9pin male D-sub connector) CPU Architecture compatible with IBM Personal Computers with a system BIOS. Optional Hot-Swap I/O Modules for backplanes that support 2, 4 or 8 I/O Modules. Discrete Input Modules - 16/32 (24V) DIs Discrete Output Modules - 16/32 (Open Source) DOs Analog Input Modules - 8/16 (4-20mA) Current Input AIs Analog Input Modules - 8/16 (1-5V) Isolated Voltage Input AIs Analog Output Modules - 4/8 (4-20mA) Current Output AOs Analog Output Modules - 4/8 (1-5V) Voltage Output AOs Universal Digital Input Modules - 6/12 (12V or 24V) Isolated UDIs (for High/Low Speed Counting or Contact Closure operation) FLASH Boot/Downloader - 512kbytes contained in a single IC FLASH Memory - 2 or 4 Mbytes mounted in a 48-pin TSOP Memory (SRAM) - 1MB of soldered-down static RAM (SRAM) is implemented with two 256K x 16 asynchronous SRAMs mounted in two 44-pin TSOPs and configured ControlWaveEXP Introduction / 1-1 • • • • • • as a 1M x 32-bit array. The 44-pin TSOPs will accept the next density SRAMs, 512K x 16 for a total of 2MB. PC/104-Plus Bus (BBI Proprietary) for system expansion - A 33MHz, 32-bit Peripheral Component Interconnect (PCI) 2.2 specification compliant bus interface is provided on a 120-pin connector. The PC/104-Plus Bus supports an optional BBI 3.3V powered secondary communications board (SCB). SCBs contain two RS-485 and two RS-232 serial ports. Backplane I/O Bus with separate data, address and control buffers, supported by four interrupt lines (IOBIRQ1-4) and a 6MHz I/O Bus Clock. 10/100BaseT Ethernet port implemented by a SMCS LAN91C111 MAC + PHY Chip. The built-in transceiver provides a Full/Half-duplex auto negotiation implementation with a RJ-45 10/100BaseT Connector (J4). Port 80 Display - implemented by two TI TIL311 Displays on the CPU Board and intended for POST codes during system boot as well as for run time status information. Battery backup for the real-time clock and the system’s SRAM is provided by an external 3.6V, 950mA-hr lithium ½ AA cell battery connected to the CPU via a 3-pin connector. Watchdog MOSFET Switch connections for alarm, annunciation and/or control. The signal /WDOGB (that drives the Watchdog MOSFET Switch) is generated by the CPU Module when improper software operation is detected. This function is supported by the Idle LED and the Watchdog LED on the CPU Module. Figure 1-1 - ControlWave™ I/O Expansion Rack with 8 I/O Modules 1-2 / Introduction ControlWaveEXP 1.2 PHYSICAL DESCRIPTION ControlWave™ I/O Expansion Racks are comprised of the following major components: • • • • • CPU Module (see Section 1.2.1) & System Battery (see Section 1.2.1.3) Power Supply/Sequencer Module (see Section 1.2.2) Backplane Assembly (supports 2, 4 or 8 I/O Modules (see Section 1.2.3) Chassis Assembly (see Section 1.2.4) One or more I/O Modules (2, 4 or 8 Max.) (see Section 1.2.5) 1.2.1 CPU Module The CPU Module houses the CPU Board and if present the optional Secondary Communications Board (SCB). The multilayer CPU Board provides ControlWaveEXP CPU, I/O monitor/control, memory and communication functions and operates over an extended temperature range with long-term product reliability. ControlWaveEXP CPU Boards are based on Intel’s 386EX Integrated microprocessor. In addition to the processor and control logic, the CPU board includes: one RS-232 COM port, one RS-232 or RS-485 COM port, 1 or 2 MB SRAM, Boot/Downloader in Flash, 2 or 4 MB Flash, an I/O bus connector, Serial Real Time Clock, and a 10/100BaseT Ethernet port. • 386EX Processor featuring: 32-bit internal architecture 25-MHz processor core Timer/Counter unit Watchdog timer Programmable chip selects with wait state generation Programmable I/O pins Interrupt control unit Two UARTs Power Management DMA and bus arbiter unit • 512kB Flash Boot/Downloader, 29LV040B, 90 ns, 8-bit access • 1 or 2 MB SRAM, 3.3V, 256K x 16, 55 nsec, with battery back-up • 2 or 4 MB simultaneous read/write Flash, 1M x 16, 90 nsec. or 2M x 16, 90 nsec. • RS-232 serial COM port • RS-232 or RS-485 serial COM port • I/O Bus interface capable of driving up to 8 slots • 10/100baseT Ethernet interface implemented by SMSC LAN91C111 MAC + PHY chip • MAC address/ configuration in serial EEPROM • Serial Real Time Clock with battery backup • Diagnostic display • 8-position general purpose DIP Switch (SW1) • 8-position Configuration DIP Switch (SW2) for Comm. Port 2 (COM2) • 4-position Recovery/Battery Enable DIP Switch (SW3) • Reset Button (Momentary) Figure 1-2 provides the CPU Module block diagram. The shaded components of Figure 1-2 are components that are only available on optional Secondary Comm. Boards. ControlWaveEXP Introduction / 1-3 Figure 1-2 - Block Diagram of ControlWave™ I/O Expansion Rack CPU Board Two basic versions of the CPU Module are available: CPU Bd. (CPU has 2 RS-232 & 1 Ethernet Ports) (without SCB) CPU Bd. (CPU has 1 RS-232, 1 RS-485 & 1 Ethernet Ports) (without SCB) Note: CPU Modules with an RS-485 Port assigned to CPU Comm. Port 2, aren’t available with a Secondary Communications Board (SCB). The Boot/CPU Operating Firmware is contained in a single 512 Kbyte uniform sector FLASH IC (referred to as the Boot/Downloader FLASH). This device resides on the Local Bus, operates at 3.3V and is configured for 8-bit access. The CPU Board contains a 48-pin TSOP site that accepts FLASH devices ranging in density from 2 to 4 Mbytes. Units are factory configured for from 2 to 4 Mbytes of industrial simultaneous read/write (SMR) FLASH memory. The FLASH memory provides 16-bit read/write access and is connected to the Local Bus. The base version of the CPU Module has 1Mbyte of soldered-down static RAM, implemented with two 256K x 16 asynchronous 70ns SRAMs that are configured as a 1M x 32-bit array. SRAM operate at 3.3V and are packaged in 44-pin TSOPs. An additional 1Mbyte of SRAM may be factory added to raise the board total to 2Mbyte. 1-4 / Introduction ControlWaveEXP SRAM is placed into data retention mode (powered by a backup 3.6V lithium battery) when power is lost. The SRAM supports 16-bit or 8-bit accesses and is connected to the Local Bus. 1.2.1.1 CPU Module Connectors The CPU Modules contains nine (9) user accessible interface connectors. Their functionality is summarized in Table 1-1. Table 1-1- User Accessible CPU Module Connector Summary Ref. J1 J2 J3 J4 J6 J1 J2 J3 J4 # Pins 9-pin 9-pin 8-pin 132-pin 3-pin 8-pin 9-pin 8-pin 8-pin Function COM1 male D-sub (RS-232) COM2 male D-sub (RS-232 or RS-485) Ethernet 10/100Base-T RJ-45 I/O Bus Connector Battery Connector COM3 RJ-45 (RS-485) COM4 male D-sub (RS-485) COM5 RJ-45 (RS-232) COM6 RJ-45 (RS-232) Notes see Figure 4-2 & Table 4-2 see Figure 4-2 & Table 4-3 see Figure 4-4 & Table 4-5 see Figure 4-1 see Figure 4-5 SCB - see Figure 4-3 & Table 4-4 SCB - see Figure 4-2 & Table 4-3 SCB - see Figure 4-3 & Table 4-4 SCB - see Figure 4-3 & Table 4-4 Figure 1-3A - ControlWave I/O Expansion Rack CPU Module (without SCB) CPU Board Comm. Port Connectors J1 and J2 and SCB Comm. Port Connector J2 The CPU Module supports up to three external 9-pin RS-232 serial ports (COM1, COM2 & COM4. COM1 (J1), COM2 (J2) and COM4 (J2 - located on the Secondary Communications Board (SCB) a PC/104 Plus expansion option) utilize standard 9-pin male D-sub connectors and are PC/AT compatible ports. COM4 is factory configured for Isolated RS-485 operation. COM2 can be factory configured for isolated RS-485 operation if the SCB option is not present. ControlWaveEXP Introduction / 1-5 Figure 1-3B - ControlWave I/O Expansion Rack CPU Module (with SCB) CPU Module Comm. Port Connectors J1, J3 and J4 (SCB) Three 8-pin RJ-45 connectors (J1, J3 and J4) are provided on the Secondary Communications Board (SCB). COM5 (J3) and COM6 (J4) support RS-232 operation. COM3 (J1) is factory configured for isolated RS-485 operation. Ethernet Port Connector J3 An Ethernet port is supported via an 8-pin RJ-45 connector. The 10/100BaseT Ethernet interface is implemented using an SMSC LAN91C111 controller. This device logically resides on the ISA bus and provides a full/half-duplex auto negotiation implementation. CPU Board I/OB Connector J4 CPU Board I/O Bus connector J4 provides a 132-pin interface between slot #2 (P2) of the Backplane PCB and the CPU Module. Separate data, address and control buffers provide access to the I/O bus which in turn provides 2, 4 or 8 slots of memory mapped I/O Modules. The CPU Board interface to the I/O Modules is level shifted to a 5V bus through a set of buffers and transceivers that are capable of driving up to eight I/O Modules. The I/O Bus Clock is a free running 6MHz clock. A signal originating from the power supply sequencer (on the Power Supply Module) disables the I/O bus buffers during insertion and removal of I/O Modules. Four interrupt lines are provided for the I/O bus (IOBIRQ1, 2, 3 & 4). The interrupt request inputs are pulled to ground to reduce power consumption due to the active driver setup used on the I/O Modules. An IRQ signal is driven high when an interrupt is generated. The IRQ inputs will be held high by the interrupting I/O Module until the CPUs interrupt service routine has begun servicing it. 1-6 / Introduction ControlWaveEXP CPU Board Battery Connector J6 CPU Board connector J6 provides a 3-pin interface to an external 3.6V Lithium Battery that is a component of the CPU Module. The 3.6V, 950mA-hr lithium ½ AA cell battery provides backup power for the real-time clock, CMOS RAM and the system’s Static RAM (SRAM). Battery backup is enabled when CPU Module switch SW3-4 is set to the ON position. 1.2.1.2 CPU Module Switches Cutouts are provided in the CPU Module to provide user access to the configuration switches. Two user configurable DIP switches are provided on the CPU Board’s right side (users left); eight-bit DIP switch SW1 is provided for user configuration settings while fourbit DIP switch SW3 provides battery back-up and forced recovery functions. The CPU Board’s left side (users right) has one eight-bit DIP switch (SW2) that provides configuration for Comm. Port 2 (COM2) with loopback control for RS-232 operation or loopback, termination control, and receiver bias settings for isolated RS-485 operation. The optional Secondary Communications Board (SCB) has two eight position DIP switches (SW1 for COM3 & SW2 for COM4) that provide loopback, termination control, and receiver bias settings for isolated RS-485 operation associated with these Comm. Ports. For all DIP switches, an OFF switch is read as “one,” and an ON switch is read as “zero.” Table 1-2 - CPU Bd. Switch SW1 - User Configurations Switch Function SW1-1 Watchdog Enable SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 Lock/Unlock Soft Switches Use/Ignore Soft Switches Normal Run or Core Updump SRAM Control Redundancy Enable/Disable Unit A/Unit B Enable WINDIAG Setting ON = Watchdog circuit is enabled OFF = Watchdog circuit is disabled ON = Write to Soft Switches or FLASH files OFF = Soft Switches, configurations and FLASH files are locked ON = Use Soft Switches (configured in FLASH) OFF = Ignore Soft Switch Configuration and use factory defaults ON = Normal Run Mode OFF = Causes the system to start a Core Updump ON = Retain values in SRAM during restarts OFF = Force system to reinitialize SRAM ON = Redundancy Disable OFF = Redundancy Enable ON = CPU assigned as ‘A’ CPU – OFF = CPU assigned as ‘B’ CPU ON = Don’t allow WINDIAG to run test OFF = Disable boot project and allow WINDIAG to run test Table 1-3 - CPU Bd. SW3 - Firmware Load Control/Recovery Mode/Battery Enable Switch SW3-1 Function Not Used System Firmware Load Control * Setting ON = Disable remote download of System Firmware OFF = Enable remote download of System Firmware ON = Force recovery mode (via CW Console) SW3-3 Force Recovery Mode OFF = Recovery mode disabled SRAM & RTC ON = Battery back-up enabled SW3-4 Battery Enable OFF = Battery back-up disabled * = Boot PROM version 06 or higher and System PROM version 4.7 or higher SW3-2 ControlWaveEXP Introduction / 1-7 Table 1-4 Assignments of CPU Bd. Switch SW2 and SCB Bd. Switches SW1 & SW2 Comm. Ports 2, 3, & 4 Loopback & Termination Control (Respectively) Switch 1 2 3 4 5 RS-232 Function (COM2) Switch ON DTR to DSR Loopback TXD to RXD Loopback N/A N/A RTS to CTS Loopback 6 N/A 7 8 N/A N/A RS-485 Function Switch ON TX+ to RX+ Loopback TX- to RX- Loopback 100 Ohm RX+ Termination 100 Ohm RX- Termination N/A Slow Slew Rate - Open = Fast Closed = Slow RX+ Bias (End Node) RX- Bias (End Node) Setting ON - Only for Diagnostics ON - Only for Diagnostics ON - End Nodes Only ON - End Nodes Only ON - Only for Diagnostics ON/OFF - As required Factory Default = ON ON - End Nodes Only ON - End Nodes Only The Momentary Reset Button allows the user to reset (stop and restart) the ControlWaveEXP when the unit is being tested via WINDIAG. 1.2.1.3 CPU Module System Battery The CPU Board connects to an external battery via a three-pin connector (J10). This 3.6V, 950mA-hr lithium ½ AA cell (battery) provides backup for the real-time clock and the System SRAM. The system SRAM is specified to have a standby current of 50:A maximum for each part. For a system containing 1MB or 2MB of System SRAM, a worst-case current draw of 110:A allows a battery life of approximately 8508 hours. A supervisory circuit is used to switch to battery power when VCC falls below VCC-10%. For maximum shelf life, the battery may be isolated from the circuit by setting switch SW34 (on the CPU Board) to the OFF position. If the Real-time clock looses its battery backup a ControlWave Designer system variable bit (_QUEST_DATE) is set at the host. This bit can be used to post a message or alarm to the PC (see the ‘Systems Variables’ section of the ControlWave Designer Programmer’s Handbook D5125). 1.2.1.4 CPU Module LEDs and LCDs All CPU Modules have eight (8) LEDs on the CPU Board. Units equipped with the optional Secondary Communications Board (SCB) have eight (8) additional LEDs. Additionally, all CPU Modules are provided with a Port 80 Display assembly consisting of two TI TIL311 Displays that are visible from the front of the CPU Module. The Port 80 LCD Display assembly provides POST codes during system boot as well as run time status indication. During normal system operation, the Port 80 Display is powered down. 1.2.1.5 CPU Module Memory Summary A brief synopsis of CPU Module memory is provided herein. Boot/Download FLASH 512 Kbytes contained in a single IC. Boot/Recovery Firmware that runs the CPU Board is contained in this device. The Boot/Recovery Firmware is contained in a single 512 Kbyte 1-8 / Introduction ControlWaveEXP Uniform Sector FLASH (USF) IC. This device resides on the Local bus, operates at 3.3V and is configured for 8-bit access. Figure 1-4 - CPU Module LEDs Switch SW3-3 provides for forced update/recovery of the CPU Operating System via a user prompted menu (at a PC) or via a boot from the Boot Firmware. If SW3-3 has been set to the OFF (open) position when a reset occurs, the boot-up code passes control to the built-in Recovery Command Processor that sends a recovery menu out to the user via the recovery serial connection (Comm. Port 1) and a terminal program running on an external host computer. FLASH Memory 2 Mbytes to 4 Mbytes simultaneous read/write (non-volatile) FLASH mounted in a 48-pin TSOP. The System Firmware is stored here. The FLASH memory is configured for 16-bit read/write access and is connected to the Local bus. No hardware write protection is provided for the FLASH array. Static RAM Memory (SRAM) 1 Mbyte of soldered-down static RAM (SRAM) is implemented with two 256K x 16 asynchronous 70ns SRAMs that are configured as a 256K x 32-bit array. Each SRAM device operates at 3.3V and is packaged in a 44-pin TSOP. An additional 1Mbytes of SRAM may be factory installed. SRAM is placed into data retention mode (powered by a backup 3.6V lithium battery) when power is lost. The SRAM supports 16-bit or 8-bit accesses and is connected to the Local bus. Critical system information that must be retained during power outages or when the system has been disabled for maintenance is stored here. Data includes: Last states of all I/O. 1.2.2 Power Supply/Sequencer Module The Power Supply/Sequencer Module (PSSM) plugs into the system’s Backplane Board (Connector P1) via Compact PCI (CPCI) type keyed 110-pin connector J1. The front of the ControlWaveEXP Introduction / 1-9 PSSM contains a system power switch, as well as two pluggable terminal blocks for external input power, watchdog MOSFET switch and redundant unit selection connections. Three LEDs, visible through the front panel, provide the following status conditions: PWRGOOD (power good: green), MC (master clear active: red) and PWRFAIL (power fail: red) PSSMs contain a DC to DC Converter that generates isolated voltages (+5Vdc (VCC), +12Vdc and -12Vdc) for the CPU and various I/O Modules that plug into the Backplane Board. A piggy-back converter board provides the +3.3Vdc required for CPU logic, memory and FLASH devices. Figure 1-5 - Power Supply/Sequencer Module Also contained on the PSSM is the sequencer circuit that monitors the incoming power as well as the isolated output supplies and has a reset/early power fail warning controller that interfaces with the system CPU Module. Master Clear and Power Fail signals are generated by the sequencer circuit when incoming power or the isolated supply voltages fall below specified limits. Additionally, the sequencer circuit controls an on-board watchdog MOSFET switch that will open when Master Clear is active or the CPU Module asserts the Watchdog Bad signal. The power supply operates from +10.6 to +20V or +20.7 to +30V (dc) with the nominal input supply configuration (12V or 24V) factory set by on-board jumpers. A supervisory circuit 1-10 / Introduction ControlWaveEXP monitors the incoming power and the isolated supply voltages. The isolated supplies are shut down when the incoming voltage drops below +10.6V for a +12V system or +20.7V, for a +24V system. The circuit that drives the watchdog MOSFET switch is on the secondary side of the power supply. A solid state relay (SSR) actuates the watchdog hardware and is factory enabled or disabled via an on-board jumper. When either /MC or /WDOGB is active, the on-board watchdog hardware will be OFF. /WDOGB is a signal generated by the CPU Module when its hardware detects improper software operation. Figure 1-6 - Power Supply/Sequencer Module Block Diagram The watchdog MOSFET switch is powered via the VI input of the terminal block and its switched output is connected to the VO/NO output of the terminal block. The external power source connected to the COM terminal must be referenced to the return point of the input source that powers the PSSM (-VIN (PSGND). PSSMs provide hot swap capability to allow insertion or extraction of I/O modules into or from the Backplane assembly while the unit is powered. Neither the CPU Module or PSSM ControlWaveEXP Introduction / 1-11 are hot swappable. PSSM circuitry monitors two signals from each I/O module to detect board insertion or extraction events. The PSSM Hot Swap Monitor (HSM) will inform the CPU of these events and instruct the CPU to tristate all I/O module bus interface signals after an appropriate delay. Additionally, the PSSM HSM will generate a slot specific, I/O module master clear signal, until the insertion or extraction has been completed. In the event that the PSSM sequencer generates a master clear signal in response to power supply input or output conditions, the hot swap monitor (HSM) will generate Master Clear signals for all I/O module slots. 1.2.2.1 PSSM Power Switch SW1 Switch SW1 is used to connect input power to PSSM circuitry and shared or separate field voltage sources to I/O Modules via Controlled Power MOSFETs when the I side of the switch has been pressed to its actuated position. This will turn the unit ON. 1.2.2.2 PSSB Board Fuses The PSSM contains two fuses that aren’t field replaceable. Slow Blow Fuse F1 is rated at 3A for a +12V/24V system - protects the entire system. Slow Blow Fuse F2 is rated at 10A protects I/O Module field supplies. 1.2.2.3 Board Connectors Connectors TB1, TB2 and J1 function as described below. PSSB Bd. Terminal Block Connector TB1 TB1 provides 2 watchdog MOSFET switch connections: TB1-1 = VO - Watchdog MOSFET Switch Output TB1-2 = VI - Watchdog MOSFET Switch Input TB1-3 = VR - Redundant Unit Control Input PSSB Bd. Terminal Block Connector TB2 TB2 provides 5 input connections for bulk power: TB2-1 = (+VIN) (+10.6V to +20V dc for +12V supply) (+20.7V to +30V dc for +24V supply) TB2-2 = (+VINF) Connected to TB2-1 or +9Vdc to +30Vdc supply TB2-3 = (-VIN) (1st Supply Ground) TB2-4 = (-VINF) (2nd Supply Ground) Internally connected to TB2-3 TB2-5 = Chassis Ground - CHASSIS ( ) PSSB Bd. Connector J1 Connector J1 is a 110-pin keyed CPCI type connector that interfaces Power, Ground and Master Clear(s), I/O Board resident status/control (/BDINSLTn, /SWSn, /HBIR_NMI & /IOBTRI), power supply status (/PWR_FAIL) and watchdog status (/WDOGB) signals to Connector P1 on the Backplane Board. 1.2.2.4 PSSM LEDs Three LEDs, visible through the front panel, will provide status conditions PWRGOOD (power good: green), MC (master clear active: red) and PWRDOWN (power down: red). 1-12 / Introduction ControlWaveEXP When power is first applied or when the unit is reset, the red MC LED will illuminate for a short period of time. The green PWRGOOD LED should be ON whenever the unit is running and no power problems have been detected. The red PWRDOWN LED should only be ON when power has dropped below acceptable levels. Figure 1-7 - ControlWaveEXP Backplane Assemblies ControlWaveEXP Introduction / 1-13 1.2.3 ControlWaveEXP Backplanes ControlWaveEXP Backplanes provide for the interconnection of the Power Supply/Sequencer Module (PSSM), CPU Module and I/O Modules. Backplane Assembly versions are available in three versions, i.e., for supporting 2, 4 or 8 I/O modules. All module slot connections are implemented with Compact PCI (CPCI) type connectors. The main complement of signals on the Backplane implement an I/O bus for data transfer between the CPU and I/O Modules. The I/O bus signal definition consists of a subset of ISA bus signals that support memory mapped I/O to the 2, 4 or 8 possible I/O Module slots. Interrupt lines are available for the first four I/O slots (P3 through P6). Note: I/O slots P7 P10 are referred to as Non Interrupt Capable slots 5 - 8. Isolated power (+5V, +12V, -12V and PCOM) from the PSSM is connected to the CPU (which also receives +3.3V) and all I/O Module slot positions. Additionally, the PSSM supplies switched field power (+VINSWS, -VIN (PSGND)) to all I/O Module slots. The power supply monitor/sequencer circuit (within the PSSM) provides /MC and PWR_FAIL signals to the CPU thus providing properly timed early warning of low input or supply voltages followed by a CPU reset to support the WARM START CPU function. The watchdog circuitry on the PSSM is controlled by CPU signal /WDOGB. Figure 1-8 - Backplane Assembly with Connector Coding Devices Installed. The hot swap monitor (HSM) circuitry within the PSSM provides for the safe insertion and extraction of I/O modules under power by coordinating interface signal conditioning to the involved I/O slot with the CPU and the involved I/O Module. During detected hot swap events, the HSM receives hot swap status signals /BDINSLT1 - /BDINSLT8 and /SWS1 1-14 / Introduction ControlWaveEXP /SWS8 from their respective I/O slots, issues properly timed /HBIR_NMI and /IOBTRI signals to the CPU Module and outputs /MCn to the associated I/O slot (where n is the involved slot number). 1.2.3.1 I/O Module Access I/O memory address space is a contiguous 64KB area addressed by IOBA0 - IOBA15. Each I/O module has a 16-bit general purpose address decoder and can be plugged into any of the eight available slots. 128 bytes of memory are assigned per I/O module for local address space and block size. Each I/O slot connector has a uniquely hardwired 3-bit slot address (SLOT0 - SLOT2) to provide for CPU differentiation of up to 8 I/O slot modules. Interrupt access is available for I/O slots 1 through 4 (P3 - P6) only. Table 1-5 - Backplane Connector Coding Key Assignment Connector # P1 P2 P3 - P10 Module Type Power Supply CPU I/O Coding Device Color Yellow Blue Green Connectors P1 through P10 are equipped with connector coding devices. These color-coded devices are physically unique to ensure that only the correct module type can be installed. Modules are equipped with mating connector coding devices (yellow, blue or green) that provide the service technician with a quick visual indication of the backplane slot(s) where the module in question can physically reside. Figure 1-9 - Backplane PCB Block Diagram ControlWaveEXP Introduction / 1-15 1.2.4 ControlWave I/O Expansion Rack Chassis The ControlWaveEXP Backplane PCB and the modules that comprise the system are housed in a Stainless Steel Chassis designed to accommodate 2, 4 or 8 I/O Modules. Any ControlWave I/O Expansion Rack Chassis can be panel/wall mounted. ControlWave I/O Expansion Rack Chassis that support 8 I/O Modules can be mounted to a 19-inch equipment rack in lieu of panel/wall mounting. ControlWave I/O Expansion Rack Chassis are factory shipped without any modules installed. The Chassis assembly also contains a Ground Lug that accommodates up to a #4 AWG Ground Wire. Grounding the unit is accomplished by connecting a ground wire between the Ground Lug and a known good Earth Ground. Figure 1-10 - The Chassis Assembly (with & without Bezel) 1-16 / Introduction ControlWaveEXP 1.2.5 ControlWaveEXP I/O Modules Five I/O Modules are available factory configured for either local or remote field device wiring termination. I/O Modules are factory configured, encased, and factory sealed. A brief overview of each I/O Module type is provided below. I/O Module specifications are covered in Section 4.5. 1.2.5.1 Analog Input Module Two types of AI Modules are available, i.e., 4-20mA or 1-5 Vdc input versions. Each module contains field interface circuitry for up to 16 or 8 analog inputs. Each AI Module consists of a Terminal Board Assembly, an Analog Input PCB, an LED PCB, an LED Housing Assembly, a Terminal Housing Assembly, as well as I/O assembly and mounting hardware. AI PCBs are connected to their associated Terminal Board Assembly via a 44-pin header and to the ControlWaveEXP Backplane via a 110-pin connector. Figure 1-11 - ControlWave I/O Module ControlWaveEXP Introduction / 1-17 1.2.5.2 Analog Output Module AO Modules are factory configured to support either 4-20mA or 1-5 Vdc analog outputs. Each module contains field interface circuitry for up to 8 or 4 analog outputs. Each AO Module consists of a Terminal Board Assembly, an Analog Output PCB (with a daughter board when configured for 1-5V operation), an LED Housing Assembly, a Terminal Housing Assembly, as well as I/O assembly and mounting hardware. Each AO PCB is connected to its associated Terminal Board Assembly via a 44-pin header and to the unit’s Backplane via a 110-pin connector. 1.2.5.3 Digital Input Module ControlWave DI Modules are factory configured to support either externally powered source or dry contact DI applications. Each module contains field interface circuitry for up to 32 or 16 discrete inputs with an input range of 24Vdc, a nominal input current is 5mA and 30 millisecond input filtering. Each DI Module consists of a Terminal Board Assembly, a Discrete Input PCB, an LED PCB, an LED Housing Assembly, a Terminal Housing Assembly, as well as I/O assembly and mounting hardware. Each DI PCB is connected to its associated Terminal Block Assembly via a 44-pin header and to the unit’s Backplane via a 110-pin connector. 1.2.5.4 Digital Output Module Digital Output (DO) Modules provide a total of 32 or 16 DOs for control of signaling functions. Each output contains an optically isolated open source MOSFET and surge suppressor that are capable of handling 500mA @ 31V. Each DO Module consists of a Terminal Board Assembly, a Discrete Input PCB, an LED PCB, an LED Housing Assembly, a Terminal Housing Assembly, as well as I/O assembly and mounting hardware. Each DO PCB is connected to its associated Terminal Block Assembly via a 44-pin header and to the unit’s Backplane via a 110-pin connector. 1.2.5.5 Universal Digital Input Module Universal Digital Input (UDI) Modules provide a total of 12 or 6 inputs. Each input is optically isolated from the field device. UDI Modules are factory configured with all inputs set with debounce enabled or with all inputs set with debounce disabled. With debounce enabled, spurious pulses caused by relay contact bounce are eliminated. Individual UDI inputs can be customer configured for a polled input, interrupt on change of state (COS) or totalizer operation. Field inputs can be driven signals, open collector outputs or relay contacts. The maximum input frequency is 10 kHz. For any input used as a totalizer, the maximum totalized count before rollover is 65535 and the totalizer is not resetable through software. Each UDI Module consists of a Terminal Board Assembly, a Universal Digital Input PCB, an LED PCB, an LED Housing Assembly, a Terminal Housing Assembly, as well as I/O assembly and mounting hardware. Each UDI PCB is connected to its associated Terminal Block Assembly via a 44-pin header and to the unit’s Backplane via a 110-pin connector. 1-18 / Introduction ControlWaveEXP Section 2 INSTALLATION & OPERATION 2.1 INSTALLATION IN HAZARDOUS AREAS ControlWave I/O Expansion Racks are not furnished in a housing. The modules that comprise the system are housed in a Stainless Steel Chassis designed to accommodate 2, 4 or 8 I/O Modules. Any ControlWave I/O Expansion Rack Chassis can be panel/wall mounted. ControlWave I/O Expansion Rack Chassis that support 8 I/O Modules can be mounted to a 19” equipment rack in lieu of wall/panel mounting. Use in Class I, Division 2, Groups A, B, C and D hazardous areas will require the selection of an appropriate enclosure that meets the NEMA Type 3X or 4X specification. Figure 2-1 - 8-I/O Module ControlWave - Mounting Diagram ControlWaveEXP Installation & Operation / 2-1 Figure 2-2 - 4-I/O Module ControlWave - Mounting Dimensions Figure 2-3 - 2-I/O Module ControlWave - Mounting Dimensions 2-2 / Installation & Operation CI-ControlWaveEXP 2.2 INSTALLATION SITE CONSIDERATIONS Check all clearances when choosing an installation site. Make sure that the ControlWave I/O Expansion Rack will be accessible for wiring and service. To install the ControlWave I/O Expansion Rack Chassis, see Section 2.3.1. 2.2.1 Temperature & Humidity Limits ControlWave I/O Expansion Racks have been designed to operate over a -40°F to +158°F (-40°C to +70°C) temperature range (with storage at up to +185°F (+85°C)) and a 0% to 95% Relative Humidity range. Make sure that the ambient temperature and humidity at the measuring site remains within these limits. Operation beyond these ranges could cause output errors and erratic performance. Prolonged operation under extreme conditions could also result in failure of the unit. 2.2.2 Vibration Limits Check the mounted enclosure, panel or equipment rack for mechanical vibrations. Make sure that the ControlWave I/O Expansion Rack is not exposed to a level of vibration that exceeds those given in the specifications. The ControlWave’s vibration limits are 1g for 10 150 Hz & .5g for 150 - 2000 Hz. 2.3 INSTALLATION/CONFIGURATION ControlWave I/O Expansion Racks are shipped from the factory in separately boxed modules as follows: Chassis Assembly Power Supply/Sequencer Module CPU Module & Bezel AO - Analog Output Module AI - Analog Input Module DO - Digital Output Module DI - Digital Input Module UDI - Universal Digital Input Module Overview of Configuration An overview of the three (3) steps required to configure a ControlWave I/O Expansion Rack are provided below. For additional details refer to the ControlWave I/O Expansion Rack Quick Setup Guide - document # D5122. Step 1. Hardware Configuration This involves unpacking the ControlWave I/O Expansion Rack hardware, mounting the chassis, installing I/O modules, wiring I/O terminations, making proper ground connections, connecting a communication cable to the PC workstation and setting switches. To install and configure the ControlWave I/O Expansion Rack follow steps 1 through 12 below: 1. Remove the Chassis from its carton and install it at its assigned work site (see Section 2.3.1). ControlWaveEXP Installation & Operation / 2-3 2. Remove the PSSM Module from its carton and install it into Chassis slot 1, i.e., the first slot from the left end of the installed unit (see Section 2.3.2). 3. Remove the CPU Module from its carton and install it into Chassis slot 2, i.e., the second slot from the left end of the installed unit. CPU Module DIP Switches may be configured before or after the module has been installed into the Chassis. See Section 2.3.3. 4. Configure/Connect appropriate communication port(s) (see Section 2.3.3.2). Connect COMM. Port 1 or 2 of the ControlWave (depending on CPU Switch SW1 settings – see Section 2.3.3.1) to a COMM. Port of a PC (typically PC COMM. Port 1). Note: ControlWave COMM. Port 1 can only be used if CPU Switch SW1-8 has been set ON. 5. Remove any I/O Modules from their cartons and install them into the ControlWave Chassis. I/O Modules reside in slots 3 through 4, 3 through 6 or 3 through 10 for units supporting 2, 4 or 8 I/O Modules respectively. Install I/O wiring to each I/O Module (see Section 2.3.4). 6. Install a ground wire between the Chassis Ground Lug and a known good Earth Ground (see Section 2.3.1.1). 7. Install Watchdog MOSFET Switch wiring and if required Redundancy Control wiring (see Section 2.3.5.3). 8. Connect Bulk DC Power to the ControlWave’s PSSM Module (see Sections 2.3.5.1 & 2.3.5.2). 9. Install the Bezel so that it covers the PSSM and CPU Modules (see Section 2.3.7). 10. Plug an Ethernet cable from your network into the CPUs Ethernet Port (J1). 11. Open the Bezel door and apply power to the ControlWave I/O Expansion Rack by setting the Power Switch on the PSSM Module to the ‘I’ position. 12. When the ControlWave I/O Expansion Rack completes its power-on sequence, the Port 80 Display should be blank. Step 2. Setting Configuration Parameters This section describes how to establish communications with the rack using LocalView, and how to use the Flash Configuration Utility to specify an Ethernet Port for the rack. This section also discusses how to set up certain IP and application parameters. 1. Start LocalView and establish communications with the I/O rack (Local Mode). 2. When communications are established, call up the Flash Configuration utility from within LocalView, by right-clicking on the RTU icon, and choosing "RTUÆRTU Configuration Parameters". 3. Sign on with a username and password, then do the following: • On the 'Ports' page of the Flash Configuration Utility, define an Ethernet Port for the I/O rack. It must have a valid IP address. 2-4 / Installation & Operation CI-ControlWaveEXP • • On the 'IP Parameters' page, specify the IP address of the host ControlWave controller in the "IP ADDR A" field. On the 'Application Parameters' page, specify a "Power Fail Timeout" value, which determines what happens to output values when the I/O rack's power is restored following a power failure. Then specify a "Host Comm Loss Timeout" value, which determines what happens to output values when the I/O rack loses communications with its host ControlWave controller. 4. Click on the [Save to Rtu] button to save these changes to the I/O rack. 5. Power off the I/O rack, then turn it back on to activate the newly saved parameters. Step 3. Setting up the Host to Reference the I/O Expansion Rack This section shows how to use the I/O Configuration Wizard in ControlWave Designer to modify the ControlWave Project in the host controller, so that it can make use of the boards in the I/O Expansion Rack. Now that the I/O Expansion Rack is configured, you must make reference to its boards in the ControlWave project of the host ControlWave controller. NOTE This section assumes that the following has already been done: • The host controller must have been installed. • The host controller must have a ControlWave project already defined. • ControlWave Designer software must have been installed on a PC to allow editing of the ControlWave project. 1. Start ControlWave Designer software by clicking on StartÆProgramsÆOpenBSI ToolsÆControlWave Designer 2. Open the ControlWave Project used in the Host Controller by clicking on File Æ Open Project / Unzip Project. 3. Start the I/O Configuration Wizard by clicking as follows: ViewÆIO Configurator 4. Define I/O Boards in the I/O Configuration Wizard. This involves selecting the proper board(s) from a list, specifying the IP addresses and slot numbers for the boards, and defining variable names and other parameters for the individual I/O pins. (These subjects are discussed in the ControlWave I/O Expansion Rack Quick Setup Guide document# D5122) For more details on using the I/O Configuration Wizard, see the Getting Started with ControlWave Designer Manual (document# D5085). 5. Once you have defined the I/O boards, and named the individual pins, you can reference those pin names as I/O variables within your control strategy. For more information on using variables see the Getting Started with ControlWave Designer Manual (document# D5085) and the ControlWave Designer Reference Manual (document# D5088). 6. Compile your revised project, and download it into the ControlWave host controller. For details on compling and downloading, see the Getting Started with ControlWave Designer Manual (document# D5085). ControlWaveEXP Installation & Operation / 2-5 2.3.1 Mounting the ControlWave I/O Expansion Rack Chassis ControlWave I/O Expansion Racks equipped with an 8-I/O Module Chassis can be mounted to a 19-inch equipment rack, a panel or a wall. These units are factory shipped with the End Plates configured for 19-inch rack mounting. When mounting one of these units to a panel or wall, it is to be positioned in accordance with the following restrictions: - - The End Plates must be removed, rotated 180° and then reinstalled to accommodate panel or wall mounting. Hole patterns and dimensions are provided in Figure 2-1. The unit must be positioned so that the front of the assembly is visible and the unit is accessible for service, i.e., installing an option or replacement of the Lithium Battery, or installation/removal of any ControlWave Module. ControlWave Modules should not be installed until the unit’s Chassis has been mounted and grounded at a designated work site. ControlWave I/O Expansion Racks that are equipped with a 2 or 4-I/O Module Chassis can be wall or panel mounted. Mounting hole patterns are provided in Figures 2-2 and 2-3 for 2I/O and 4-I/O units respectively. When mounting one of these units to a panel or wall, it is to be positioned in accordance with the following restrictions: - - The unit must be positioned so that the front of the assembly is visible and the unit is accessible for service, i.e., for replacement of the Lithium Battery, or for installation/removal of any ControlWave Module. ControlWave Modules should not be installed until the unit’s Chassis has been mounted and grounded at a designated work site. 2.3.1.1 ControlWave I/O Expansion Rack Grounding ControlWave I/O Expansion Rack Chassis are provided with a Ground Lug that accommodates up to a #4 AWG wire size. A ground wire must be run between the Chassis Ground Lug and a known good Earth Ground. The cases of the various ControlWave Modules are connected to Chassis Ground when they have been installed and secured via their two Captured Panel Fasteners. As an extra added precaution, it is recommended that a #14 AWG wire be run from PSSM Power Connector TB2-5 (Chassis Ground) to the same known good Earth Ground. The following considerations are provided for the installation of ControlWave system grounds: • Chassis Ground Lug to Earth Ground wire size should be #4 AWG. It is recommended that stranded copper wire is used and that the length should be as short as possible. • This ground wire should be clamped or brazed to the Ground Bed Conductor (that is typically a stranded copper AWG 0000 cable installed vertically or horizontally). • The wire ends should be tinned with solder prior to insertion into the Chassis Ground Lug. Note: Use a high wattage Soldering Iron. • The ground wire should be run such that any routing bend in the cable has a minimum radius of 12-inches below ground and 8-inches above ground. 2.3.2 Power Supply/Sequencer Module (PSSM) Installation The Power Supply/Sequencer Module (PSSM) must be installed prior to the installation of the CPU Module. Power and Watchdog wiring can be performed at this time, however; for safety reasons and to prevent accidental damage to the user’s bulk DC Power Supply, it is recommended that pluggable Terminal Block connectors TB1 and TB2 are not connected to the PSSM until the CPU Module has been installed, wired, and hardware configured. 2-6 / Installation & Operation CI-ControlWaveEXP Section 2.3.5.2 provides details on Watchdog Connector TB1 wiring and Section 2.3.5.1 provides details on DC Power Connector TB2 wiring. The PSSM resides in slot #1 (see Figure 2-4). 2.3.3 CPU Module Installation To configure the CPU Module, DIP Switches must be set (see Section 2.3.3.1) and Communication Ports must be wired (see Sections 2.3.3.2 through 2.3.3.4). The CPU Module resides in slot # 2 (see Figure 2-5). Figure 2-4 - PSSM Installed in ControlWaveEXP Slot #1 Figure 2-5 - PSSM & CPUM (with SCM) Installed in Slot #1 & #2 (Respectively) ControlWaveEXP Installation & Operation / 2-7 2.3.3.1 CPU Module Switch Configuration ControlWave I/O Expansion Rack CPU Module DIP Switches must be set for the desired performance options. Tables 2-1 and 2-2 provide an overview of switch settings. Note: CPU Board Switch SW2 and Secondary Comm. Board Switches SW1 and SW2 are covered in Section 2.3.3.3. SW1-1 set OFF will disable the system from entering a watchdog state when a crash or system hangup occurs. Setting SW1-1 OFF prevents the system from automatically restarting. SW1-2 set OFF prevents changing the Soft Switches, other configurations and FLASH files, i.e., these items are locked. To change Soft Switch, configuration and FLASH files SW1-2 must be set to the ON position (see Section 2.4.6). SW1-3 set OFF forces the use of Soft Switches as set per factory default (see Section 2.4.6). For use of user defined Soft Switches, SW1-3 must be set to the ON position. Note: If both SW1-3 and SW1-8 are set OFF (closed), communication ports COM1 and COM2 will be set to 9600 bps operation. SW1-4 set OFF will cause the ControlWave I/O Expansion Rack to perform a Core Updump (see Section 3.6). Set SW1-4 to the ON position for normal operation. SW1-5 set OFF forces the ControlWave I/O Expansion Rack to reinitialize SRAM when the unit recovers from a low power or power outage condition. When set ON, the contents of SRAMS will be retained and utilized when the system restarts. SW1-6 set ON will disable redundancy operation and will allow the CPU to run as a stand alone or forced application controller. Set SW1-6 to the OFF position for redundancy operation, i.e., when operating as Unit A or Unit B in conjunction with a ControlWaveRED or ControlWaveREDIO. When it is necessary to run a non-redundant application place SW1-6 to the ON position. SW1-7 set OFF will assign the CPU to System ‘B.’ Place SW1-7 to the ON position when it is desired to utilize the CPU in System ‘A.’ SW1-7 is ignored when SW1-6 is ON. SW1-8 set OFF places the unit into diagnostic mode. SW1-8 must be set OFF to run the WINDIAG program resident on the local PC (see Section 3.5). When SW1-8 has been set ON, diagnostics is disabled. SW1-8 must be set to the ON position for normal system operation, i.e. for the Boot project to run. Note: If both SW1-3 and SW1-8 are set OFF (closed), communication ports COM1 through COM6 will be set to 9600 bps operation. Table 2-1 - CPU Bd. Switch SW1 - User Configurations (ON = Factory Default) SW# Function SW1-1 Watchdog Enable SW1-2 SW1-3 SW1-4 Lock/Unlock Soft Switches Use/Ignore Soft Switches Normal Run or Core Updump 2-8 / Installation & Operation Setting - (ON = Factory Default) ON = Watchdog circuit is enabled OFF = Watchdog circuit is disabled ON = Write to Soft Switches and FLASH files OFF = Soft Switches, configurations and FLASH files are locked ON = Use Soft Switches (configured in FLASH) OFF = Ignore Soft Switch Configuration and use factory defaults ON = Normal Run Mode OFF = Causes the system to start a Core Updump CI-ControlWaveEXP Table 2-1 - CPU Bd. Switch SW1 - User Configurations Continued SW# SW1-5 Function SRAM Control SW1-7 Redundancy Enable/Disable Unit A/Unit B SW1-8 Enable WINDIAG SW1-6 Setting - (ON = Factory Default) ON = Retain values in SRAM during restarts OFF = Force system to reinitialize SRAM ON = Redundancy Disable OFF = Redundancy Enable ON = CPU assigned as ‘A’ CPU – OFF = CPU assigned as ‘B’ CPU ON = Normal Operation (don’t allow WINDIAG to run test) OFF = Allow WINDIAG to run test Table 2-2 - CPU Bd. Switch SW3 Firmware Load Control/Recovery Mode/Battery Enable Switch SW3-1 Function Not Used System Firmware Load Control * Setting ON = Disable remote download of System Firmware OFF = Enable remote download of System Firmware ON = Force recovery mode (via CW Console) SW3-3 Force Recovery Mode OFF = Recovery mode disabled ON = Battery back-up enabled SW3-4 SRAM & RTC Battery Enable OFF = Battery back-up disabled * = Boot PROM version 06 or higher and System PROM version 4.7 or higher SW3-2 Figure 2-6 - CPU Board Switches SW1 & SW3 ControlWaveEXP Installation & Operation / 2-9 2.3.3.2 Communication Ports A ControlWave I/O Expansion Racks can be configured as a Slave to a host ControlWave, Process Automation Controller, ControlWave Redundant Controller (ControlWaveRED) or ControlWave Redundant I/O and Communications Switch Unit (ControlWave-REDIO) on a Serial MODBUS or Open MODBUS network or connected to the host via IP. BSAP can be used for WINDIAG diagnostics. Up to seven communication ports are contained on the ControlWave I/O Expansion Rack’s CPU Module as follows: COM1 - Port 1: COM2 - Port 2: COM3 - Port 3: COM4 - Port 4: COM5 - Port 5: COM6 - Port 6: Ethernet Port 1: CPU Bd. J1, PC/AT 9-Pin Male D-Sub - RS-232 CPU Bd. J2, PC/AT 9-Pin Male D-Sub - RS-232 or RS-485 SCB Bd. J1, 8-Pin RJ-45 - RS-485 SCB Bd. J2, PC/AT 9-Pin Male D-Sub - RS-485 SCB Bd. J3, 8-Pin RJ-45 - RS-232 SCB Bd. J4, 8-Pin RJ-45 - RS-232 CPU Bd. J3, 8-Pin RJ-45 - Twisted Pair 10/100BaseT Figure 2-7 - CPU Module Component Identification Diagram (Front View) Communication Ports 1 through 6 support asynchronous operation. Communication Ports COM1, COM5 & COM6 support RS-232 operation while COM3 and COM4 support RS-485 operation. COM2 is factory configured per order for RS-232 or RS-485 operation. RS-232 and RS-485 Ports are protected to ±8KV ESD (Contact). Ethernet and RS-485 Ports are 2-10 / Installation & Operation CI-ControlWaveEXP isolated to 500Vdc. Note: COM2 can only be configured for RS-485 operation if the optional Secondary Comm. Board is not present. Serial communications port COM1 is factory configured for serial IP point-to-point (PPP) communications. Serial communications port COM2 is typically used during initial configuration activities for communications via LocalView. This allows the Flash Configuration Utility to be run to set configuration parameters for the I/O Expansion Rack. Serial communication ports COM3/4/5 or 6 may also be used for initial configuration activities. 2.3.3.3 RS-232 & RS-485 Interfaces Communications ports COM1, COM5 and COM6 support RS-232 communications only while ports COM3 and COM4 support RS-485 communications only. RS-232 or RS-485 communications can be provided on communications port COM2 (factory configured). These connectors are summarized below. CPU Bd. J1 CPU Bd. J2 SCB Bd. J1 SCB Bd. J2 SCB Bd. J3 SCB Bd. J4 - PC/AT 9-Pin Male D-Sub - RS-232 - COM1 - Port 1 - (see Table 2-3/Figure 2-8) PC/AT 9-Pin Male D-Sub - RS-232/RS-485 - COM2 - Port 2 - (see Table. 2-4/Fig. 2-8) 8-Pin RJ-45 - RS-485 - COM3 - Port 3 - (see Table 2-5/Figure 2-10) PC/AT 9-Pin Male D-Sub - RS-485 - COM4 - Port 4 - (see Table. 2-4/Fig. 2-8) 8-Pin RJ-45 - RS-232 - COM5 - Port 5 - (see Table 2-5/Figure 2-10) 8-Pin RJ-45 - RS-232 - COM6 - Port 6 - (see Table 2-5/Figure 2-10) RS-232 Ports An RS-232 interface supports point to point half-duplex and full-duplex communications (20 feet maximum, using data quality cable). Half-duplex communications supported by the ControlWave I/O Expansion Rack utilize MODBUS or BSAP protocol, while full-duplex is supported by the Point to Point (PPP) protocol. ControlWave I/O Expansion Rack RS-232 ports utilize the “null modem” cable (Figure 2-9A) to interconnect with other devices such as a PC, printer, or a ControlWave series unit (except CW_10/30/35) when the ControlWave I/O Expansion Rack is communicating using the full-duplex PPP protocol. The half-duplex cable shown in Figure 2-9A can be utilized when the ControlWave I/O Expansion Rack is connected to any ControlWave series unit, except the CW_10, CW_30 or CW_35. When interfacing from COM1 or COM2 to Port COM3 of either a ControlWave or ControlWaveRED unit or to COM5 or COM6 of another ControlWaveEXP, the cable of Figure 2-9B must be used along with along with one of Figure 2-9A. An illustration of the CPU Module’s male 9-pin D-type connectors is provided in Figure 2-8. Table 2-3 provides the connector pin assignments for Comm. Port 1. Table 2-4 provides the connector pin assignments for Comm. Ports 2 and 4. Table 2-5 provides the connector pin assignments for Comm. Ports 3, 5 & 6 (illustrated in Figure 2-10). Note: The following facts regarding ControlWave I/O Expansion Rack RS-232 serial Comm. ports should be observed when constructing communications cables: • DCD must be high to transmit • CTS must be high to transmit • When port is set for full-duplex operation - RTS is always ON • DTR is always high (when port is active) • When port is set for half-duplex operation - CTS must go low after RTS goes low ControlWaveEXP Installation & Operation / 2-11 Figure 2-8 - Male DB9 9-Pin Connector Associated with COM1 & COM2 RS-485 Ports ControlWave I/O Expansion Racks can use an RS-485 configured port for local network communications to multiple nodes up to 4000 feet away. Since this interface is intended for network communications, Table 2-6 provides the appropriate connections for wiring the master, 1st slave, and nth slave. Essentially, the master and the first slave transmit and receive data on opposite lines; all slaves (from the first to the "nth") are paralleled (daisy chained) across the same lines. The master node should be wired to one end of the RS-485 cable run. A 24-gauge paired conductor cable, such as Belden 9843 should be used. Note: Only half-duplex RS-485 networks are supported Figure 2-9 - Communication Port RS-232 Cable Wiring Diagrams 2-12 / Installation & Operation CI-ControlWaveEXP Table 2-3 - CPU Board Connector J1 (COM1) Pin Assignment Pin # 1 2 3 4 5 6 7 8 9 Signal RS-232 RXD TXD DTR GND RTS - Description: RS-232 Signals N/A Receive Data - Input Transmit Data - Output Data Terminal Ready - Output Signal/Power Ground N/A Request To Send - Output N/A N/A Table 2-4 - CPU Bd. Connector J2 (COM2) & SCB Bd. Connector J2 (COM4) Pin Assignments Pin # 1 2 3 4 5 6 7 8 9 Signal RS-232 DCD RXD TXD DTR GND DSR RTS CTS - COM2 Description: RS-232 Signals Data Carrier Detect Input Receive Data Input Transmit Data Output Data Terminal Ready Output Signal/Power Ground Data Set Ready Input Request To Send Output Clear To Send Input Not Used Signal RS-485 RXDTXDTXD+ ISOGND RXD+ COM2/4 Description: RS-485 Signals N/A Receive Data - Input Transmit Data - Output Transmit Data +Output Isolated Ground Receive Data + Input N/A N/A N/A To ensure that the “Receive Data” lines are in a proper state during inactive transmission periods, certain bias voltage levels must be maintained at the master and most distant slave units (end nodes). These end nodes also require the insertion of 100-Ohm terminating resistors to properly balance the network. CPU Bd. Switch SW2 (COM2), SCB Switch SW1 (COM3) and/or SCB Switch SW2 (COM4) must be configured at each node to establish proper network performance. This is accomplished by configuring CPU Bd. SW2 (COM2), SCB Switch SW1 (COM3) and/or SCB Switch SW2 (COM4) so that the 100-Ohm termination resistors and biasing networks are installed at the end nodes and are removed at all other nodes on the network (see Table 2-7 and Figures 2-8, 2-10 & 2-11). Table 2-5 - SCB Bd. Connector J1 (COM3), J3 (COM5) & J4 (COM6) Pin Assignments Pin # 1 2 3 4 5 6 7 8 Signal RS-232 DCD DSR RXD RTS TXD CTS DTR GND ControlWaveEXP COM4/5 Description: RS-232 Signals Data Carrier Detect Input Data Set Ready Input Receive Data Input Request To Send Output Transmit Data Output Clear To Send Input Data Terminal Ready Output Signal/Power Ground Signal RS-485 RXD+ RXDTXDTXD+ ISOGND COM3 Description: RS-485 Signals N/A Receive Data + Input Receive Data - Input N/A Transmit Data - Output N/A Transmit Data + Output Isolated Ground Installation & Operation / 2-13 Figure 2-10 - SCB RJ-45 Connectors J1 (COM3), J3 (COM5) & J4 (COM6) Table 2-6 - RS-485 Network Connections (see Tables 2-4 & 2-5 for ControlWave RS-485 Port Pin # Assignments) From Master TXD+ TXDRXD+ RXDISOGND To 1st Slave RXD+ RXDTXD+ TXDISOGND To nth Slave RXD+ RXDTXD+ TXDISOGND Figure 2-11 - CPU Module Comm. Port Switches 2-14 / Installation & Operation CI-ControlWaveEXP Table 2-7 - CPU Switch SW2 (COM2) & SCB Switches SW1 (COM3) & SW2 (COM4) Loopback & Termination Control Settings SWITCH # 1 2 3 4 5 RS-232 Function Switch ON DTR to DSR Loopback TXD to RXD Loopback N/A N/A RTS to CTS Loopback 6 N/A 7 8 N/A N/A RS-485 Function Switch ON TX+ to RX+ Loopback TX- to RX- Loopback 100 Ohm RX+ Termination 100 Ohm RX- Termination N/A Slow Slew Rate - ON = Fast OFF = Slow RX+ Bias (End Node) RX- Bias (End Node) Setting ON - Only for Diagnostics ON - Only for Diagnostics ON - End Nodes Only ON - End Nodes Only ON - Only for Diagnostics ON/OFF - As required Factory Default = ON ON - End Nodes Only ON - End Nodes Only Closed = Switch set OFF 2.3.3.4 Ethernet Port ControlWave I/O Expansion Rack CPU Modules contain one Ethernet Port. This Port utilizes a 100/10Base-T RJ-45 modular connector that typically provides a shielded twisted pair interface to an Ethernet Hub. ControlWave I/O Expansion Rack Ethernet Port assignment is provided below. Ethernet Port 1: CPU Bd. J3, 8-Pin RJ-45 - Shielded Twisted Pair 10/100BaseT A typical Ethernet Hub provides eight (8) 100/10Base-T RJ-45 Ports (with Port 8 having the capability to link to another Hub or to an Ethernet communications port). Both ends of the twisted pair Ethernet cable are equipped with modular RJ-45 connectors. These cables have a one-to-one wiring configuration as shown in Figure 2-14. Table 2-8 provides the assignment and definitions of the 8-pin 10/100BaseT connector. It is possible to connect two nodes in a point-to-point configuration without the use of a Hub. However, the cable used must be configured such that the TX+/- Data pins are connected to the RX+/- Data pins (swapped) at the opposite ends of the cable (see Figure 2-13). Figure 2-12 - RJ-45 Connector (Ethernet Port) J3 (CPU) ControlWaveEXP Installation & Operation / 2-15 Figure 2-13 - Point-to-Point 10BaseT Ethernet Cable The maximum length of one segment (CPU to Hub) is 100 meters (328 feet). The use of Category 5 shielded cable is recommended. Table 2-8 - Ethernet 10/100BaseT CPU Module Pin Assignments Pin # 1 2 3 4 Description Transmit Data+ (Output) Transmit Data- (Output) Receive Data+ (Input) Not Connected Pin # 5 6 7 8 Description Not Connected Receive Data- (Input) Not Connected Not Connected Note: TX & RX are swapped at Hub’s. Figure 2-14 - Standard 10BaseT Ethernet Cable (CPU Module to Hub) 2.3.4 I/O Module Installation & Wiring ControlWave I/O Expansion Rack Chassis are available with Backplane Assemblies that support 2, 4 or 8-I/O Modules. I/O Modules reside in slots 3 through 4, 3 through 6 or 3 through 10 for units supporting 2, 4 or 8-I/O Modules respectively. Figure 2-15 shows slot assignments for an 8-I/O ControlWave I/O Expansion Racks. Units that support 2 or 4-I/O Modules don’t have slots 5 through 10 or 7 through 10 respectively. 2-16 / Installation & Operation CI-ControlWaveEXP I/O Modules are configured per order and individually packaged. An I/O Module will reside in one of up to 8-I/O slots subject to the following conditions: Backplane slots 3 through 6 support interrupt or non-interrupt driven I/O Modules, while slots 7 through 10 only support non-interrupt driven I/O Modules. 2.3.4.1 Installation of I/O Modules If installing one or more I/O Modules into an already operational unit, the procedure may be performed while the unit is powered, however; the host ControlWave’s application load (ControlWave Designer software) must be configured to accept the new I/O Module(s) (via the ControlWave Designer I/O Configurator) and then the application load must be downloaded into the host ControlWave before the new I/O Module(s) can become operational. For new site installations, hardware configuration should take place with power disconnected until the entire unit has been physically installed, configured and wired. Figure 2-15 - ControlWave Chassis Slot Assignments (With & Without Bezel Installed) ControlWaveEXP Installation & Operation / 2-17 Perform steps 1 through 7 below for each I/O Module. I/O Modules are provided with a removable Terminal Housing Assembly. This assembly has a door that swings downward to provide access to the unit’s Terminal Handle which in turn is utilized to remove an installed I/O Module once the module’s Captured Panel Fasteners have been loosened. 1. Remove the I/O Module from its shipping carton and remove the Terminal Housing Assembly from the I/O Module (see Figure 2-16). 2. Turn the Terminal Block’s Quarter Turn Fasteners (counterclockwise) and remove the Terminal Block Assembly from the I/O Module. 3. I/O Modules are available that support local terminations (field wiring connected directly to the I/O Module’s Terminal Block PCB) or remote terminations (field wiring connected to a remote DIN-rail mounted Terminal Block Assembly). Figure 2-16 - Terminal Housing Assembly Removal When installing wiring in conjunction with I/O Modules that are equipped with a Local Terminal Block PCB, install the field wiring between the I/O Module’s Terminal Block Assembly and field devices (see Figure 2-17). Use AWG 14 or smaller wire (consult with the field device manufacturer for recommendations). Leave some slack and plan for wire routing, identification, maintenance, etc. The bundled wires are to be routed out 2-18 / Installation & Operation CI-ControlWaveEXP through the bottom of the I/O Module Assembly between the Terminal Block Assembly and the Terminal Housing Assembly. Figure 2-17 - I/O Module (Local Termination) Wire Routing For I/O Modules that are equipped with a Remote Terminal Block Assembly, install the cables between the I/O Module’s Terminal Block Assembly and the DIN-rail mounted Terminal Block Assembly. Install the field wiring between the DIN-rail mounted Terminal Block Assembly and field devices (see Figures 2-18, 2-22, 2-23, 2-25, 2-26, 228, 2-29, 2-34 & 2-38). Use AWG 14 or smaller wire (consult with the field device manufacturer for recommendations). Leave some slack and plan for wire routing, identification, maintenance, etc. The cables that run between the I/O Module and the DIN-Rail mountable Terminal Blocks are to be routed out through the bottom of the I/O Module Assembly between the Header Block and the Terminal Housing Assembly. To provide access to the Header Block’s lower ¼ Turn Fastener, cables associated with connectors P3 and P4 should be secured via a Tie Wrap to the lower left side of the Header Block Assembly, while cables associated with connectors P1 and P2 should be secured to the lower right side of the Header Block Assembly via a second Tie Wrap (see Figure 2-18). ControlWaveEXP Installation & Operation / 2-19 Figure 2-18 - I/O Module (Remote Termination) Wire Routing Refer to the following sections for I/O Module wiring information: 2-20 / Installation & Operation CI-ControlWaveEXP Section 2.3.4.4 = DI Module Section 2.3.4.5 = DO Module Section 2.3.4.6 = AI Module Section 2.3.4.7 = AO Module Section 2.3.4.8 = UDI Module 4. Align the I/O Module with the assigned I/O Slot and install the unit into the Chassis. When the assembly is fully seated, turn the I/O Module’s Captured Panel Fasteners (clockwise) to secure the unit to the Chassis thus establishing a low resistance path between the I/O Module and Chassis Ground. 5. Install the Local or Remote Terminal Block Assembly (with wiring harness) onto the I/O Module (turning the Quarter Turn Fasteners (clockwise). 6. Replace the module’s Terminal Housing Assembly. Note: Door Labels are available as MS Word files that can be typeset by the user to provide wiring identification for I/O Modules. These labels are available on the Bristol Babcock Web site www.controlwave.com and can be affixed to the inside of the Term. Housing’s Door. 7. Using a PC equipped with ‘ControlWave Designer’ and ‘OpenBSI’ software, con-figure the host ControlWave’s application load. ControlWave Designer software must be configured to accept the new I/O Module(s) (via the ControlWave Designer I/O Configurator) and then the application load must be downloaded into the host ControlWave Process Automation Controller CPU’s System FLASH and/or SDRAM (see Section 2.4.1) to accept the new I/O Module (and any other modules that have been added or removed) For new installations, this step can be skipped until the unit has been wired and power applied. 2.3.4.2 Wire Connections ControlWave I/O Expansion Rack I/O Modules utilize compression-type terminals that accommodate up to #14 AWG wire. A connection is made by inserting the wire’s bared end (1/4” max) into the clamp beneath the screw and securing the screw. The wire should be inserted fully so that no bare wires are exposed to cause shorts. If using standard wire, tin the bare end with solder to prevent flattening and improve conductivity. Allow some slack in the wires when making terminal connections. The slack makes the connections more manageable and minimizes mechanical strain on the terminal blocks. 2.3.4.3 Shielding and Grounding The use of twisted-pair, shielded and insulated cable for I/O signal wiring will minimize signal errors caused by electromagnetic interference (EMI), radio frequency interference (RFI) and transients. When using shielded cable, all shields should only be grounded at one point in the appropriate system. This is necessary to prevent circulating ground current loops that can cause signal errors. 2.3.4.4 Digital Inputs (see Figures 2-19, 2-20, 2-21, 2-22 & 2-23) ControlWave Digital Input (DI) Modules are factory-configured to support either externally powered source or dry contact DI applications. Each module contains field interface circuitry for up to 32 or 16 discrete inputs with an input range of 24Vdc, a nominal input current is 5mA and 30 millisecond input filtering. DI Modules consists of a Terminal Block Assembly (local) or a Header Block Assembly (remote), a Digital Input PCB, ControlWaveEXP Installation & Operation / 2-21 an LED PCB, an LED Housing Assembly, a Terminal Housing Assembly, as well as I/O assembly and mounting hardware. DI field circuitry is electrically isolated from the module’s bus interface circuitry by surge suppressors and optocouplers. Modules configured for use in dry contact applications contain a 21Vdc power supply. The 21Vdc field supply is derived from a control circuit and an isolated power supply that is powered by the output of the hot swap control circuit, which in turn is powered by the +VIN/-VIN supply interfaced from the unit’s Backplane. Each DI PCB is connected to its associated Terminal/Header Block Assembly via a 44-pin header and to the unit’s Backplane via a 110-pin connector. 2.3.4.4.1 Digital Input Configurations Digital Input Modules are factory configured to support either 32/16 externally sourced DIs or 32/16 internally sourced DIs. Modules configured for use in dry contact applications contain a 21Vdc power supply. The nominal input voltage is 24Vdc @ 5mA. Figure 2-19 - Local Terminal Block Assembly Assignments for Internally Sourced DI Operation or Externally Powered DI Operation Figure 2-20 - Internally Sourced DI Module - Wiring Diagram 2-22 / Installation & Operation CI-ControlWaveEXP Figure 2-21 - Externally Powered DI Module - Wiring Diagram Figure 2-22 - Remote DIN-Rail Mountable Terminal Block Assembly Assignments for Internally Sourced DI Operation or Externally Powered DI Operation ControlWaveEXP Installation & Operation / 2-23 Figure 2-23 - Remote DIN-Rail Mountable Terminal Block Assembly Assignments for Relay Isolated 120Vac DI Operation Field wiring assignments associated with the locally terminated DI Modules and remotely terminated DI Modules are provided in Figures 2-19 and 2-22 respectively. A special remote termination module with built-in discrete relay module that supports input from 120Vac 2-24 / Installation & Operation CI-ControlWaveEXP DIs is also available (see Figure 2-23). The special remote termination module (with built-in discrete relay module) is interfaced to an externally sourced DI Module. 2.3.4.5 Digital Outputs (see Figures 2-24, 2-25, 2-26 & 2-27) Digital Output (DO) Modules provide a total of 32 or 16 DOs for control of signaling functions. Each output contains an optically isolated open source MOSFET and surge suppressor that are capable of handling 500mA @ 31V. DO Modules consist of a Terminal Block Assembly (local) or a Header Block Assembly (remote), a Discrete Input PCB, an LED PCB, an LED Housing Assembly, a Terminal Housing Assembly, as well as I/O assembly and mounting hardware. DO field circuitry MOSFETs are electrically isolated from the module’s bus interface circuitry by surge suppressors and optocouplers. Output data is stored in an on board DO Load Register. Upon power up the DO Load register is cleared and all outputs are set “off.” Each DO PCB is connected to its associated Terminal/Header Block Assembly via a 44-pin header and to the unit’s Backplane via a 110-pin connector. 2.3.4.5.1 Digital Output Configurations Digital Output Modules provide a total of 32 or 16 DOs with surge protection. Each DO utilizes an open source MOSFET that is capable of driving up to 31Vdc at up to 500mA. A 500Vdc MOV to Chassis and a 31Vdc Transorb (across output) are provided to protect each DO. The maximum operating frequency is 20 Hz. Figure 2-24 - Local Terminal Block Assembly Assignments for Open Source Isolated DO Operation ControlWaveEXP Installation & Operation / 2-25 Field wiring assignments associated with the locally terminated DO Modules and remotely terminated DO Modules are provided in Figures 2-24 and 2-25 respectively. A special remote termination module with built-in discrete relay modules is also available (see Figure 2-26. Figure 2-25 - Remote DIN-Rail Mountable Terminal Block Assembly Assignments for Open Source Isolated DO Operation 2-26 / Installation & Operation CI-ControlWaveEXP Figure 2-26 - Remote DIN-Rail Mountable Terminal Block Assembly Assignments for Relay Isolated 24Vdc DO Operation ControlWaveEXP Installation & Operation / 2-27 Figure 2-27 - Open Source Isolated DO Module - Wiring Diagram 2.3.4.6 Analog Inputs (see Figures 2-28 through 2-33) Two types of AI Modules are available, i.e., 4-20mA or 1-5 Vdc input versions. Each module contains field interface circuitry for up to 16 or 8 analog inputs. Each AI Module consists of a Terminal Block Assembly (local) or a Header Block Assembly (remote), an Analog Input PCB, an LED PCB, an LED Housing Assembly, a Terminal Housing Assembly, as well as I/O assembly and mounting hardware. AI circuitry is electrically isolated from the module’s bus interface circuitry. On the isolated side each AI signal is channeled through signal conditioning, surge suppression, multiplexing and a 14-bit A to D converter. The bus interface circuitry consists of the control logic to access A to D converters and multiplexers, static RAM (to store the latest 14-bit digitized data for each of the sixteen channels and the on board reference voltages) and control logic to access the system bus. The common mode range for 1-5V Analog Input Modules is 31Vdc. For 4-20 mA Analog Input Modules, all inputs are referenced to the -VFXX of the module. Each AI PCB is connected to its associated Terminal Block Assembly via a 44-pin header and to the unit’s Backplane via a 110-pin connector. 2.3.4.6.1 Analog Input Configurations AI Modules (with either 16 or 8 AI) are offered with 1-5V isolated inputs or with 4-20 mA internally sourced inputs. Field wiring assignments associated with the locally terminated AI Modules are provided in Figure 2-30. Field wiring assignments associated with 4-20 mA remotely terminated AI Modules and 1-5V remotely terminated AI Modules are provided in Figures 2-28 and 2-29 respectively. Note: Cable shields associated with AI wiring should be connected to the ControlWave Chassis Ground. Multiple shield terminations will require a user supplied copper ground bus. This ground bus must be connected to the ControlWave’s Chassis Ground Lug (using up to a #4 AWG wire size) and must accommodate a connection to a known good Earth 2-28 / Installation & Operation CI-ControlWaveEXP Ground (in lieu of a direct connection from the Ground Lug) and to all AI cable shields. Shield wires should use an appropriate Term. Lug and should be secured to the copper bus via industry rugged hardware (screw/bolt, lockwasher and nuts). Figure 2-28 - Remote DIN-Rail Mountable Terminal Block Assembly Assignments for 4-20 mA AI Operation ControlWaveEXP Installation & Operation / 2-29 Figure 2-29 - Remote DIN-Rail Mountable Terminal Block Assembly Assignments for 1-5V AI Operation 2-30 / Installation & Operation CI-ControlWaveEXP Figure 2-30 - Local AI Module Terminal Blocks Assembly Assignments Figure 2-31 - Internally Sourced 4-20mA Current Loop AI - Wiring Diagram Figure 2-32 - Internally Sourced (Externally Powered) 4-20mA Current Loop AI - Wiring Diagram ControlWaveEXP Installation & Operation / 2-31 Figure 2-33 - Externally Powered Isolated 1-5 Volt AI - Wiring Diagram 2.3.4.7 Analog Outputs (see Figures 2-34, 2-35, 2-36 & 2-37) AO Modules are factory configured to support either 4-20mA or 1-5 Vdc analog outputs. Each module contains field interface circuitry for up to 8 or 4 analog outputs. Each AO Module consists of a Terminal Block Assembly (local) or a Header Block Assembly (remote), an Analog Output PCB (with a daughter board when configured for 1-5V operation), an LED PCB, an LED Housing Assembly, a Terminal Housing Assembly, as well as I/O assembly and mounting hardware. AO circuitry is electrically isolated from the module’s bus interface circuitry. On the isolated side, each AO signal passes through one of two, 4-channel digital to analog converters (DAC) that drive voltage to current converters. The V to I circuits are powered by an on board isolated 19V power supply and the DACs are powered by an isolated 5V sup-ply. Outputs are protected from transients with surge suppressors. Each AO PCB is connected to its associated Terminal Board Assembly via a 44-pin header and to the unit’s Backplane via a 110-pin connector. The maximum external load that can be connected to the 4-20mA output is 650 ohms. The maximum external load current for the 1-5V output is 5mA. An additional error (associated with the voltage output mode) is caused by the voltage drop across an inductor. This error is not compensated and is equal to the output current times two inductor resistances, e.g., 2.5 ohms x 2 x .005A = 25mV (or 0.625% of span). 2.3.4.7.1 Analog Output Configurations Analog Output Modules are factory configured to support either eight (8) 1-5V or 4-20mA isolated outputs. Field wiring assignments associated with the remotely terminated AO Modules and locally terminated AO Modules are provided in Figures 2-34 and 2-35 respectively. 2-32 / Installation & Operation CI-ControlWaveEXP Figure 2-34 - Remote DIN-Rail Mountable Terminal Block Assembly Assignments for AO 4-20mA and 1-5V Operation ControlWaveEXP Installation & Operation / 2-33 Figure 2-35 - Local AO Module Terminal Blocks Assembly Assignments Figure 2-36 - 4-20mA Current Loop AO - Wiring Diagrams Figure 2-37 - 1-5Vdc Voltage AO - Wiring Diagrams 2-34 / Installation & Operation CI-ControlWaveEXP 2.3.4.8 Universal Digital Input Modules (see Figures 2-38 through 3-41) Universal Digital Input (UDI) Modules provide a total of 12 or 6 inputs. Each input is optically isolated from the field device. UDI Module inputs are factory configured with all inputs set with debounce enabled or with all inputs set with debounce disabled. With debounce enabled, spurious pulses caused by relay contact bounce are not counted. Individual UDI inputs can be customer configured for a polled input or totalizer operation. Field inputs can be driven signals, open collector outputs or relay contacts. The maximum input frequency is 10 kHz. For any input used as a totalizer, the maximum totalized count before rollover is 65535 and the totalizer is not resetable through software. Each UDI Module consists of a Terminal Board Assembly (local) or a Header Block Assembly (remote), a Universal Input PCB, an LED PCB, an LED Housing Assembly, a Terminal Housing Assembly, as well as I/O assembly and mounting hardware. Universal Digital Input Module circuitry consists of signal conditioning circuitry, 4-bit accumulators and a microcontroller. Signal conditioning circuitry includes optocouplers, debounce circuitry and bandwidth limit circuitry. The microcontroller monitors and maintains delays for each input. Each input of the UDI Module can be configured as a polled input with a 30 millisecond filter or a 16-bit high speed counter with a 20 usec filter. UDI circuits with debounce disabled have two field inputs, SET and COM. When the debounce circuitry is enabled (factory), a change of state on both the SET and RESET field inputs is required to accumulate counts. The maximum input frequency is 10 kHz with a nominal input current of 5mA. Delay registers for signal conditioning allow individual inputs to utilize one of three software selectable delays. The 20 usec delay is used for the 10 kHz input range required for high speed counting. The 1 millisecond delay is required for low speed counter applications. 30 millisecond delays are required for general purpose inputs or contacts where contact bounce may be an issue. 2.3.4.8.1 Universal Digital Input Configurations UDI Modules provide a total of 12 or 6 UIs with surge protection. Each UDI Module is capable of handling 24V inputs. The field inputs are provided electrical isolation of 500Vdc to Chassis and 1500Vdc to system logic. Each input is also protected with a 31dc Transorb (across input and to Field Common) that meets the ANSI/IEEE standard C37.90-1978. Field wiring assignments associated with the remotely terminated UDI Modules and locally terminated UDI Modules are provided in Figures 2-38 and 2-39 respectively. ControlWaveEXP Installation & Operation / 2-35 Figure 2-38 - Remote DIN-Rail Mountable Terminal Block Assembly Assignments for UDI Operation 2-36 / Installation & Operation CI-ControlWaveEXP Figure 2-39 - Local UDI Terminal Block/Configuration Diagram Figure 2-40 - UDI (Debounce Enabled) Wiring Diagram Figure 2-41 - UDI (Debounce Disabled) Wiring Diagram ControlWaveEXP Installation & Operation / 2-37 2.3.5 Power Supply Wiring ControlWave PSSMs utilize compression-type terminals that accommodate up to #14 AWG wire. A connection is made by inserting the wire’s bared end (1/4” max) into the clamp adjacent to the screw and then securing the screw. The wire should be inserted fully so that no bare wires are exposed to cause shorts. If using standard wire, tin the bare end with solder to prevent flattening and improve conductivity. Figure 2-42 - PSSM Wire Routing Diagram Allow some slack in the wires when making terminal connections. The slack makes the connections more manageable and helps to minimize mechanical strain on the terminal blocks. 2.3.5.1 Bulk Power Supply Current Requirements ControlWave I/O Expansion Racks are equipped with either a 12Vdc or 24Vdc Power Supply Sequencer Module (PSSM). The maximum current required for the +12Vdc or +24Vdc bulk power supply used with a particular ControlWave I/O Expansion Rack can be estimated as follows: 2-38 / Installation & Operation CI-ControlWaveEXP Bulk +12/24Vdc Supply Current = CPU* + Sum of all I/O Modules CPU, Chassis & PSSM 16 point AI Module 8 point AI Module 4 or 8 point AO Module 16 or 32 point DI Module 16 or 32 point DO Module 6 or 12 point UDI Module - 1A (with/without SCB) 2A per module 1A per module 1A per module 1A per module (see Tables 2-9 & 2-10) (no surge current) (see Tables 2-9 & 2-10) (no surge current) This summation will accommodate steady state as well as power up in-rush current draw. Note: When two bulk power supplies are required, the first supply (VIN) (see Fig. 2-43) must be rated to handle 2 Amps. Table 2-9 and 2-10 provide detailed steady state and loop power current requirements for each ControlWave module. Table 2-9 - Power Requirements for Bulk 12Vdc Power Supply COMPONENTS CPU, CHASSIS, PSSM FPAI (4-20mA) - F. Populated HPAI (4-20mA) - H. Populated FPAI (1-5V) - F. Populated HPAI (1-5V) - H. Populated FPAO (4-20mA) - F. Populated HPAO (4-20mA) - H. Populated FPAO (1-5V) - F. Populated HPAO (1-5V) - H. Populated FPDI - F. Populated HPDI - H. Populated FPDO - F. Populated HPDO - H. Populated FPUDI - F. Populated HPUDI - H. Populated MAX # of I/O N/A 16 8 16 8 8 4 8 4 32 16 32 16 12 6 SYSTEM A = 580mA D = 81mA D’ = 72.2mA E = 76.2mA E’ = 68.5mA F = 39.9mA F’ = 39.9mA G = 39.9mA G’ = 39.9mA H = 58.3mA H’ = 31.6mA I = 85.1mA I’ = 45.2mA J = 54.2mA J’ = 33.3mA FIELD 12Vdc N/A K = 51.5mA K’ = 27.1mA 0mA 0mA L = 22.4mA L’ = 22.4mA M = 82.1mA M’ = 53.3mA N = 27.1mA N’ = 27.1mA 0mA 0mA 0mA 0mA NOTES CPU with Ethernet Add 50mA/Loop Add 47.3mA/Loop Add 52.2mA/Loop - Output @ 5mA Add 9.47mA/Loop - Dry Contact Table 2-10 - Power Requirements for Bulk 24Vdc Power Supply COMPONENTS CPU, CHASSIS, PSSM CPU/SCB, CHASSIS, PSSM CPU/SCB, CHASSIS, PSSM FPAI (4-20mA) - F. Populated HPAI (4-20mA) - H. Populated FPAI (1-5V) - F. Populated HPAI (1-5V) - H. Populated FPAO (4-20mA) - F. Populated HPAO (4-20mA) - H. Populated FPAO (1-5V) - F. Populated HPAO (1-5V) - H. Populated FPDI - F. Populated HPDI - H. Populated FPDO - F. Populated HPDO - H. Populated FPUDI - F. Populated HPUDI - H. Populated ControlWaveEXP MAX # of I/O N/A N/A N/A 16 8 16 8 8 4 8 4 32 16 32 16 12 6 SYSTEM A = 290mA B = 400mA C = 310mA D = 40.5mA D’ = 36.1mA E = 38.1mA E’ = 34.3mA F = 20.0mA F’ = 20.0mA G = 20.0mA G’ = 20.0mA H = 29.2mA H’ = 15.8mA I = 42.6mA I’ = 22.6mA J = 27.1mA J’ = 16.7mA FIELD 24Vdc N/A N/A N/A K = 52.2mA K’ = 29.7mA 0mA 0mA L = 26.9mA L’ = 26.9mA M = 56.8mA M’ = 41.9mA N = 29.7mA N’ = 29.7mA 0mA 0mA 0mA 0mA NOTES CPU with Ethernet CPU w/Ethernet SCB w/Ethernet CPU w/Ethernet, SCB w/2-RS-232 Add 25mA/Loop Add 23.6mA/Loop Add 26.1mA/Loop - Output @ 5mA Add 4.74mA/Loop - Dry Contact Installation & Operation / 2-39 2.3.5.2 Power Wiring DC Power is interconnected to the PSSM via Connector TB2. One or two Bulk DC supplies can be connected to the ControlWave PSSM. The Bulk DC supply (nominally +12Vdc or +24Vdc) connected to TB2-1 (+VIN) is converted, regulated and filtered by the PSSM to produce +5Vdc, +3.3Vdc, +12Vdc (optional) and -12Vdc (optional). This PSSM circuit is fused at 3A and is referred to as the LOGIC Supply since these voltages are used for CPU, communications and I/O logic. The bulk DC (+9.0 to +30 Vdc) supply connected to TB2-2 (+VINF) is fused and switched by the PSSM before being supplied to all I/O. I/O Modules use this supply to power field devices and I/O field interface circuitry. This PSSM circuit is fused at 10A and is referred to as the FIELD Supply. Figure 2-43 - PSSM TB2 Typical Wiring Schemes The operating range of the LOGIC Supply is +10.6 to +20.0 Vdc (nominal +12Vdc input source) or +20.7 to +30.0 Vdc (nominal +24Vdc input source). The operating range of the FIELD Supply is +9.0 to +30.0 Vdc. 2-40 / Installation & Operation CI-ControlWaveEXP PSSM Connector TB2 provides 5 input connections for bulk power as follows: TB2-1 = TB2-2 = TB2-3 = TB2-4 = TB2-5 = (+VIN) (+10.6V to +20V dc for +12V supply) (+20.7V to +30V dc for +24V supply) (+VINF) Connected to TB2-1 or +9Vdc to +30Vdc supply (-VIN) (1st Supply Ground) (-VINF) (2nd Supply Ground) Internally connected to TB2-3 Chassis Ground - CHASSIS (;) 2.3.5.3 Watchdog Switch & Redundant Unit Wiring (see Figs. 2-42, 2-43, 2-44A & 2-44B) The circuit that drives the Watchdog MOSFET switch is on the secondary side of the power supply. A solid state relay (SSR) actuates the watchdog hardware and is factory enabled or disabled via an on-board jumper. When either the Master Clear or Watchdog Bad signal are active, the on-board watchdog hardware will be OFF. Watchdog Bad is a signal generated by the CPU Module when its hardware detects improper software operation. Figure 2-44A - Watchdog MOSFET Switch Field Wiring Figure 2-44B - ControlWaveEXP to ControlWaveREDIO Redundancy Field Wiring ControlWaveEXP Installation & Operation / 2-41 The watchdog MOSFET switch is powered via the VI input of the terminal block (TB1-2) and its switched output is connected to the VO output of the terminal block (TB1-1). The external power source connected to the VI terminal must be referenced to the return point of the input source that powers the PSSM [-VIN or PSGND (TB2-3)]. PSSM Connector TB1 provides Watchdog MOSFET Switch and Redundancy Control connections as follows: MOSFET Connections: (see Figures 2-42, 2-43 & 2-44) TB1-1 = VO - Watchdog MOSFET Switch Output TB1-2 = VI - Watchdog MOSFET Switch Input TB1-3 = VR - Redundancy Unit Control Input (Used with ControlWaveREDIO) 2.3.6 Installation of the Lithium Backup Battery (see Figs. 2-5, 2-7 & 2-45) The 3.6V Lithium backup battery located on the CPU Module connects to CPU Board connector J6. This 950mA-hr lithium ½ AA cell battery is provided with a three-wire connector (2-wires used). The battery provides backup for the real-time clock and the system SRAM. A supervisory circuit is used to switch to battery power when VCC falls below VCC - 10%. The Battery PCB provides a regulated +2.5Vdc to the CPU Module. Figure 2-45 - Lithium Backup Battery Removal Diagram 2-42 / Installation & Operation CI-ControlWaveEXP The system SRAM has a standby current draw of 50uA maximum for each part. For a unit containing 1MB of SRAM, a worst-case current draw of 110uA allows a battery life of approximately 8508 hours, while for a unit containing 2MB of SRAM, a worst-case current draw of 210uA results in a battery life of approximately 4254 hours. CPU Board Switch SW3-4 must be set to the ON position to enable the battery. For maximum shelf life, the battery may be isolated from the circuit by moving CPU Board Switch SW3-4 to the OFF position. The CPU Module is shipped with the Lithium backup battery installed. To remove the Lithium backup battery, the Battery Retaining Clip must be removed from the Battery Holder Assembly (see Figure 2-45). Once the replacement battery has been installed into the Battery Holder Assembly on the Battery Backup PCB Assembly, the Battery Retaining Clip can be easily snapped back into place. 2.3.7 Installation of the Bezel Assembly (see Figures 2-5 & 2-46) The Bezel assembly covers the front of the PSSM and CPU Modules and acts like the I/O Module’s Terminal Housing Assembly by providing the following functions: It can be removed or its Terminal Door opened to access the PSSM and CPU modules. Bundled wires and cables are routed downward between the modules and the Bezel. The Bezel is functional and its appearance is contiguous with the I/O Modules. Figure 2-46 - Bezel Assembly (for CPU Module without SCB) The appropriate Bezel assembly is shipped with the CPU Module and should be installed whenever the unit is operational (except during service). The Bezel is secured to the Chassis by two snaps. To remove the Bezel assembly, gently grasp its sides and pull out and away from the Chassis. ControlWaveEXP Installation & Operation / 2-43 Installation of the Bezel assembly requires that its snaps be aligned with their mating holders on the Chassis. Once the Bezel has been properly positioned on the Chassis, a slight push should snap it into place. 2.4 OPERATIONAL DETAILS ControlWave Process Automation Controllers are shipped from the factory with firmware that allows the unit to be configured in conjunction with an IEC 61131 application program. This section provides information as follows: - Steps required to configure and download the host ControlWave’s application load. Steps required to download system firmware. Operation of the CPU Module’s Reset Switch Module Hot Swapping Soft Switch Configurations and Communication Ports Operational details on ControlWave LEDs, the PORT 80 Display and use of the BBI WinDiag program for fault isolation are provided in Chapter 3. 2.4.1 Configuring & Downloading the Application Load A host ControlWave Process Automation Controller must receive its configured application load before it and the slave ControlWave I/O Expansion Rack can be placed into operation. This will require connection of the ControlWave unit to a PC running Windows NT (4.0 or higher), Windows 2000 or Windows XP Professional and equipped with ControlWave Designer software & OpenBSI software. Configuration of the application load must be performed by an individual familiar with the various programming tools. The following software user documentation is referenced: Getting Started with ControlWave Designer Manual - D5085 ControlWave Designer Reference Manual - D5088 Open BSI Utilities Manual - D5081 Open BSI Technician’s Toolkit - D5087 An application load download can be initiated, i.e., from ControlWave Designer, or from the OpenBSI 1131 Downloader for ControlWave Nodes. See Section 2.4.1 steps 1 through 3 of instruction manual CI-ControlWave. 2.4.2 Upgrading ControlWave I/O Expansion Rack Firmware ControlWave I/O Expansion Rack CPUs ship from the factory with system firmware already installed. If an upgrade of the system firmware is required, use one of the procedures below to download the new or replacement firmware from the PC. Upgrade of system firmware via LocalView FLASH Mode requires OpenBSI 5.1 (or newer). If you have an older version of OpenBSI, FLASH upgrades are to be performed via Hyperterminal. You will need a binary (*.BIN) system firmware file, and that file should be defined in the Flash Master File (FLASH.MST). A sample Flash Master File is shown, below: cwr0410.bin Firmware - Release 04.1 2-44 / Installation & Operation CI-ControlWaveEXP Upgrade of an unattended ControlWaveEXP can be accomplished from a remote PC. This capability is introduced in Section 2.3.2.3. 2.4.2.1 Using LocalView to Upgrade ControlWaveEXP Firmware NOTE Your ControlWaveEXP must be set to Recovery Mode ENABLE (ON) prior to performing the FLASH upgrade, then set to Recovery Mode DISABLE (OFF) after the upgrade. On the ControlWave this is accomplished via CPU Switch SW3-3. Also set CPU Switch SW1-3 (OFF) to ignore soft switch configuration and use factory defaults; set SW1-3 (ON) after the upgrade. A null modem cable (see Figure 2-9) must be connected to COM1 of the ControlWaveEXP and to any RS-232 port on the associated PC. The PC’s RS-232 port used for this purpose must be set to run at 115.2 Kbaud. ControlWaveEXP CPU Switch SW3, position, 3 must be set ON. Start LocalView, Choose FLASH, Enter A Name, Click on [Create] Start LocalView by clicking on: Start Æ Programs Æ OpenBSI Tools Æ LocalView. The New View Mode dialog box will appear (see Figure 2-47). "Mode" Choose 'Flash' for the mode. "Name" Enter a name for the View Mode File in the "Name" field. Figure 2-47 - Local View - New View Mode Menu "Location" If you want to store the View Mode File in a directory other than that shown in the "Location" field, enter the new location there, or use the [Browse] push button to find the directory. When the "Mode", "Name", and "Location" have been specified, click on the [Create] push button to activate the Communication Setup Wizard (see Figure 2-48). Step 1 - Communication Setup Complete the fields in the Communication Setup Wizard as described, below. "What port would you like to use?" Specify the PC port you would like to use; this would be the port on the PC which will be connected to the serial cable, e.g. COM1:, COM2:, etc. ControlWaveEXP Installation & Operation / 2-45 "Would you like to use auto baud rate detection?" / "What baud rate would you like to use?" If you know which baud rate to use, answer no for auto baud detection, and specify the baud rate. If you do not know which baud rate to use, choose auto baud detection. Figure 2-48 - Communication Setup: Step 1 Menu [Advanced Parameters] See the ‘Advanced Communication Parameters Dialog Box’ section, later in this chapter for details on this. Click on the [Next] pushbutton to activate the next wizard (see Figure 2-49). Step 2 - Flash RTU Setup In the Flash RTU Setup Wizard (see Figure 2-49), complete the fields as described, below: "What is the type of the RTU?" Use the list box to select the type of controller you are connected to. In this case, you should only choose from among the ControlWave-series options: Select this option: ControlWaveEXP For this type of unit: ControlWave I/O Expansion Rack " What is the local address of the RTU that you would like to connect to?" Select the BSAP local address of the ControlWave unit (from 1 to 127) using the list box provided. 2-46 / Installation & Operation CI-ControlWaveEXP Click on the [Next] push button to activate the Flash Data Setup Wizard. Figure 2-49 - Flash RTU Setup Menu Step 3 - Flash Data Setup Complete the fields in the Flash Data Setup Wizard (see Figure 2-50), as described, below: "Please enter the name of the binary file to Flash" To upgrade system firmware, you must specify the path and name of a binary (*.BIN) file on your hard disk containing the firmware. Normally, the contents of the various available BIN files are described in a Flash Master File (see box at bottom of the dialog box). If you have specified a Flash Master File, double-click on the description of the binary file you want to download to the RTU. Its path and name will be copied into this field. (If you do NOT have a Flash Master File, type the path and name of the binary file directly into this field.) "Location of Flash Master File" Specifies the location of the Flash Master File (FLASH.MST). The contents of the FLASH Master File will be displayed in the box at the bottom of the dialog box, and may be used to select binary files for FLASH downloading. (See above). If necessary, you can use the [Browse] push button to locate the FLASH Master File. Click on [Finish] to install the specified BIN file in FLASH memory at the RTU. Once the Flash download has begun, you will NOT be allowed to shut down LocalView, unless you cancel the download, or it has been completed. The progress of the Flash download will be displayed in the window. Any mismatch in file versions, or if the type of .BIN file does not match the type of RTU, the download will be aborted ControlWaveEXP Installation & Operation / 2-47 Figure 2-50 - Flash Data Setup Menu Figure 2-51 - Local View Downloading System Firmware Menu 2-48 / Installation & Operation CI-ControlWaveEXP Advanced Communication Parameters Dialog Box Figure 2-52 - Local View Advanced Communication Parameters Menu “What is the Link Level Timeout Period” This defines the maximum amount of time (in seconds) that Open BSI will wait to receive a response to any one data link transaction. If 0 is entered as the link timeout period, the system will use a default timeout calculated based on the baud rate of the line. "Would you like to use RTS/CTS signals?" If your communication line uses Ready to Send (RTS) / Clear to Send (CTS) signals (not to be confused with ControlWave variables used for this purpose), click on 'Yes'. "Front Pad", "Back Pad" These fields specify the number of null characters to insert at the beginning (front) or ending (back) of a message. Null characters may be useful in situations where there may be a momentary delay, which could cause the start of a message to be missed, for example, while a radio link is being activated. To determine the delay caused by null packing, perform the following calculation: seconds of delay = (number of null characters x 10) / baud rate 2.4.2.2 Using Hyperterminal to Upgrade ControlWaveEXP Firmware A null modem cable (see Figure 2-9) must be connected to COM1 of the ControlWaveEXP and to any RS-232 port on the associated PC. The PC’s RS-232 port used for this purpose must be set to run at 115.2 Kbaud. ControlWaveEXP CPU Switch SW3, position, 3 must be set ON. 1. If not already running, apply power to the associated PC. 2. Start the HyperTerminal program on the PC. Note: HyperTerminal is a Windows 95 (or newer) application utility program. If using HyperTerminal for the first time, set the communications properties (for the PC Port being utilized) via the Properties Menu as follows: Bits per second: = 115200, Data bits: = 8, Parity: = None, Stop bits: = 1, and Flow control: = None and then click OK. ControlWaveEXP Installation & Operation / 2-49 3. Set CPU Switch SW3 position 3 to ON (ON = Force Recovery). 4. Apply power by turning the PSSM’s ON/OFF Switch to the ON (‘I’) position. The resident BIOS will initialize and test the hardware, this process is referred to as POST (Power On Self Test). A status of the POST progress is displayed on the Port 80 display. Unless there is a problem these codes will scroll at a fast rate and won’t be discernable. Successful completion is indicated with an 86 on the Port 80 display and with the cold start menu being displayed on the PC’s screen. Detection of a fault will be indicated by a 2-digit code on the Port 80 display. Refer to Section 3.4.3 for POST Status Code definition. From the Hyperterminal Recovery Mode menu (Figure 2-53), press the ‘F’ key to enter FLASH download. A message will be displayed warning that the FLASH is about to be erased; press the ‘Y’ key at the prompt. The screen will display dots as the flash devices are being erased; this could take a few minutes. Figure 2-53 - HyperTerminal Recovery Mode Menu 5. When the FLASH is ready for download the letter C will be displayed on the screen. In the HyperTerminal command bar click on Transfer and then Send File…(see Figure 254). In the Send File Dialog Box (see Figure 2-55), select “1KXmodem” for the protocol, enter the filename of the appropriate .bin file in the format “CWPxxxxx.bin” (where xxxxx varies from release to release). Click on the Send button to start the download (see Figures 2-55 and 2-56). When the HyperTerminal Recovery Mode Menu of Figure 253 appears, the download has completed. 6. Close the HyperTerminal program. The null modem cable connected between the ControlWaveEXP and the PC can be removed if desired. 2-50 / Installation & Operation CI-ControlWaveEXP Figure 2-54 - HyperTerminal FLASH Download Menu (Ready to Download) - (Transfer/Send File Selected) Figure 2-55 - HyperTermal Flash Download (Send File Dialog Box - Enter Filename) 7. Set CPU Switch SW3 position 3 to OFF (OFF = Recovery Mode Disabled). Switch Power OFF and then ON again via the PSSM’s ON/OFF Switch. Once the ControlWave is running its application load, status codes posted to the Port 80 Display have a different meaning than the Port 80 POST Status Codes (see Section 3.4.3 for POST Status Codes). The PORT 80 Display is disabled during normal running operation to save power. These Port 80 Running Status (Hex) Codes are listed in Table 211. ControlWaveEXP Installation & Operation / 2-51 Figure 2-56 - HyperTerminal FLASH Download (Download in Process) Table 2-11 - PORT 80 - Running Status Codes Hex Code 00 1D 51 86* D0 D1 F0 FE 5E BF CA CF FA Definition No Application Currently Loading the Boot Project System Initialization in Progress Recovery Mode Diagnostic Mode Running Diagnostic NPX Error FLASH Programming Error System Start Error Battery Fail Hot Card Replacement in Progress Invalid Checksum Detected CPU Bd. Switch SW1-3 Set OFF Ignore Soft Switch Configuration Use factory defaults Notes SW3-3 = ON SW1-8 = OFF Unit Stopped Check SW3-4 Unit Stopped Flashes for 1 second At startup Core Dump in process or waiting to start FF Unit Crashed Unit Stopped FC Waiting for Alt. Watchdog Timer Unit Stopped * Not an actual Running Status Code - SW3-3 should be OFF FD Waiting for Updump 2.4.2.3 Remote Upgrade of ControlWaveEXP Firmware It is possible to download system firmware into an unattended remote ControlWaveEXP. This function can only be accomplished if CPU Board Switch SW3-2 (associated with the unit in question) is set in the OFF position (factory default). The procedure for performing a remote download of system firmware is discussed in Appendix J of the Open BSI Utilities Manual (document D5081). Note: Remote upgrade of ControlWaveEXP Firmware requires Boot PROM version 4.7 or higher and System PROM version 4.7 or higher. 2-52 / Installation & Operation CI-ControlWaveEXP 2.4.3 Operation of The Reset Switch (Button) The CPU Module’s Reset Switch is a momentary button that allows the operator to reset (stop and restart) the ControlWaveEXP when the unit is being tested via WINDIAG. Never use this switch during normal operation. 2.4.4 Module Hot Swapping The CPU’s Hot Swap circuitry provides for installation and removal of any or all I/O Modules while the unit is running its application load (RUN Mode). When an I/O Module is initially removed or installed, the ControlWave I/O Expansion Rack halts operation for 300 milliseconds before resuming operation from where it halted. To replace an I/O Module, follow the steps in sections 2.4.5.1 and 2.4.5.2 below. 2.4.4.1 I/O Module Hot Swap Removal 1. Shut down or place under manual control all processes associated with the I/O Module being removed. Note: Although more than one I/O Module can be removed while power is applied to the unit, the service technician must never remove or insert more than one I/O Module at a time. 2. Remove the Terminal Housing Assembly (see Figure 2-16). 3. Turn the Terminal Board’s Quarter Turn Fasteners (counterclockwise), grasp the Terminal Handle and remove the Terminal Board Assembly (with wiring harness) from the I/O module. 4. Turn the I/O Module’s Captured Panel Fasteners (counterclockwise) until it can be removed from the Chassis. Remove the I/O Module assembly in question from the ControlWave I/O Expansion Rack’s Chassis. 5. If not already done, remove the Terminal Board Assembly from the replacement I/O Module. 2.4.4.2 I/O Module Hot Swap Installation 1. Install the replacement I/O Module into the same I/O slot that the I/O Module assembly in question was removed from. When the assembly is fully seated, turn the I/O Module’s Panel Fasteners (clockwise) to secure the unit to the Chassis. 2. Install the original Terminal Board Assembly (with wiring harness) onto the replacement I/O Module (turning the Quarter Turn Fasteners (clockwise). 3. Replace the Terminal Housing Assembly. 4. Remove from manual control any processes associated with the I/O Module. 2.4.5 Soft Switch Configuration and Communication Ports Firmware defined soft switches that control many default settings for various system operating parameters such as BSAP Local Address, EBSAP Group Number, communication port parameters, etc., can be viewed and, if desired, changed via ‘Configuration Web Pages’ in Microsoft Internet Explorer via the Flash Configuration Utility. When connecting the ControlWave I/O Expansion Rack to the PC (local or network) for the first time you should be aware of the communication port default parameter settings provided below (see Figures 2-6 through 2-10). Note: Communication port factory defaults can be enabled anytime by setting CPU Board Switch SW1-3 to the OFF position. COM1: From the factory, COM1 defaults to 9600 bps (RS-232) using the Internet Point to Point Protocol (PPP). Note: ControlWave Port COM1 will be configured for RS-232 ControlWaveEXP Installation & Operation / 2-53 operation (at 9600 baud) by setting CPU Switches SW1-3 and SW1-8 OFF. This places the unit into diagnostic mode. To test COM1 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. Connection to a PC requires the use of an RS-232 “Null Modem” cable (see Figure 2-9). If the PC is equipped with an RS-232 Port that utilizes an RJ-45 jack, use either a special “Null Modem” cable equipped with an RJ-45 male plug and wired like the null modem cable of Figure 2-9A, or use Bristol “Null Modem” cable P/N 39284301-3 connected to a Bristol “RJ45 to DB9 Adapter” cable P/N 392844-01-0 (see Figures 2-9A & 2-9B), to interconnect the PC to COM1. COM2: When factory set for RS-232 or RS-485 operation, COM2 defaults to 9600 baud, 8bits, no parity, 1 stop bit, BSAP/ControlWave Designer protocol operation. To test COM2 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. In lieu of the use of COM1, an RS232 “Null Modem” cable (see Figure 2-9A) can be connected between COM2 and the PC (typically COM1) or an RS-485 cable (see Tables 2-4 & 2-6) can be connected between COM2 and the PC’s RS-485 Port. If the PC is equipped with an RS-232 Port that utilizes an RJ-45 jack, use either a special “Null Modem” cable equipped with an RJ-45 male plug and wired like the null modem cable of Figure 2-9A, or use Bristol “Null Modem” cable P/N 39284301-3 connected to a Bristol “RJ45 to DB9 Adapter” cable P/N 392844-01-0 (see Figures 2-9A & 2-9B), to interconnect the PC to COM2. If RS-485 communications is required an RS-485 cable can be assembled using the connections provided in Tables 2-4 and 2-6. COM3: Factory set for RS-485 operation, COM3 defaults to 9600 baud, 8-bits, no parity, 1 stop bit, BSAP/ControlWave Designer protocol operation. To test COM3 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. In lieu of the use of COM1, an RS-485 cable (see Tables 2-5 & 2-6) can be connected between COM3 and the PC’s RS-485 Port. Use Adapter cable P/N 392844-01-0 as required (see Figure 2-9B). COM4: Factory set for RS-485 operation, COM4 defaults to 9600 baud, 8-bits, no parity, 1 stop bit, BSAP/ControlWave Designer protocol operation. To test COM4 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. In lieu of the use of COM1, an RS-485 cable (see Tables 2-4 & 2-6) can be connected between COM4 and the PC’s RS-485 Port. Use Adapter cable P/N 392844-01-0 as required (see Figure 2-9B). COM5: RS-232 Port COM5 defaults to 9600 baud, 8-bits, no parity, 1 stop bit, BSAP/ControlWave Designer protocol operation. To test COM5 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. In lieu of the use of COM1, an RS-232 “Null Modem” cable (see Figure 2-9A) can be connected between COM5 and the PC (typically COM1). If the PC is equipped with an RS-232 Port that utilizes an RJ-45 jack, use either a special “Null Modem” cable equipped with RJ-45 male plugs and wired like the null modem cable of Figure 2-9A, or use Bristol “Null Modem” cable P/N 392843- 2-54 / Installation & Operation CI-ControlWaveEXP 01-3 connected to two Bristol “RJ45 to DB9 Adapter” cables P/N 392844-01-0 (see Figures 2-9A & 2-9B), to interconnect the PC to COM5. COM6: RS-232 Port COM6 defaults to 9600 baud, 8-bits, no parity, 1 stop bit, BSAP/ControlWave Designer protocol operation. To test COM6 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. In lieu of the use of COM1, an RS-232 “Null Modem” cable (see Figure 2-9) can be connected between COM6 and the PC (typically COM1). If the PC is equipped with an RS-232 Port that utilizes an RJ-45 jack, use either a special “Null Modem” cable equipped with RJ-45 male plugs and wired like the null modem cable of Figure 2-9A, or use Bristol “Null Modem” cable P/N 39284301-3 connected to two Bristol “RJ45 to DB9 Adapter” cables P/N 392844-01-0 (see Figures 2-9A & 2-9B), to interconnect the PC to COM6. Others: The Ethernet Port can be connected directly or via a network to a PC equipped with an Ethernet Port (see Figures 2-7 and 2-11 through 2-14). If not configured with an address, the ControlWave I/O Expansion Rack uses DHCP (by default) to obtain an IP address. Note: If you are going to use an Open Modbus device to communicate with the ControlWave I/O Expansion Rack, refer to Appendix B. ControlWaveEXP Installation & Operation / 2-55 BLANK PAGE Section 3 SERVICE 3.1 SERVICE INTRODUCTION This section provides general, diagnostic and test information for the ControlWave I/O Expansion Rack. The service procedures described herein will require the following equipment: 1. 2. 3. 4. PC with null modem interface cable & Bristol’s WINDIAG Software Loop-back plug, 9-pin female D-Sub & 8-pin male RJ-45 (for RS-232) (see Figure 3-11) Loop-back plug, 9-pin female D-Sub & 8-pin male RJ-45 (for RS-485) (see Figure 3-12) Loop-back plug, 8-pin male RJ-45 (for twisted pair Ethernet) (see Figure 3-13) The following test equipment can be used to test the Power Supply/Sequencer Module: 1. DMM (Digital Multimeter): 5-1/2 digit resolution 2. Variable DC Supply: Variable to 30Vdc @ 2.5A (with vernier adjustment) When ControlWave I/O Expansion Racks are serviced on site, it is recommended that any associated processes be closed down or placed under manual control. This precaution will prevent any processes from accidentally running out of control when tests are conducted. Warning Harmful electrical potentials may still be present at the field wiring terminals even though the ControlWave I/O Expansion Rack’s power source may be turned off or disconnected. Do not attempt to unplug termination connectors or perform any wiring operations until all the associated supply sources are turned off and/or disconnected. Warning Always turn off any external supply sources used for externally powered I/O circuits, before changing any modules. 3.2 COMPONENT REMOVAL/REPLACEMENT PROCEDURES This section provides information on accessing ControlWave I/O Expansion Rack modules for testing, installation/removal procedures and I/O Module Hot Swapping. 3.2.1 Accessing Modules For Testing Testing and replacement of ControlWave I/O Expansion Rack modules should only be performed by technically qualified persons. Familiarity with the disassembly and test procedures described in this manual are required before starting. Any damage to the ControlWave I/O Expansion Rack resulting from improper handling or incorrect service procedures will not be covered under the product warranty agreement. If these procedures cannot be performed properly, the unit should be returned to Bristol (with prior authorization from Bristol Inc.) for factory evaluation and repairs. All Modules (PSSM, CI-ControlWaveEXP Service / 3-1 CPU & I/O) are factory sealed to prevent tampering; if the seal is broken by other than Bristol Inc. personnel, the warranty is void. 3.2.2 Removal/Replacement of the Bezel Assembly Before the CPU Module can be removed, the Bezel Assembly (that covers the PSSM and the CPUM) must be removed from the Chassis. 1. Remove any I/O Module from Chassis Slot 3. Grasp the sides of the Bezel Assembly and gently pull it off the Chassis. 2. To replace the Bezel Assembly, align the Bezel’s two snaps (top and bottom) (one near the top and one near the bottom) with their receptacles on the Chassis (centered between the PSSM’s and CPUM’s Captured Panel Fastener holes). 3.2.3 Removal/Replacement of the CPU Module 1. Remove the Bezel Assembly (see section 3.2.2). 2. If the ControlWave I/O Expansion Rack is running, place any critical control processes under manual control and shut down the unit by setting the PSSM Power Switch to the ‘O’ position. 3. Loosen the two Captured Panel Fasteners that secure the CPU Module to the Chassis and then carefully slide the CPU Module out of the front of the Chassis. 4. To replace the CPU Module, the Power Supply/Sequencer Module must be installed (see Section 3.2.4). Carefully align the CPU Module with Chassis Slot 2 and insert the unit into the Chassis. When the assembly is fully seated (CPU Module Connector J1 has mated with Backplane Connector P2), turn the module’s Captured Panel Fasteners (clockwise) to secure CPU Module to the Chassis thus establishing a low resistance path between the CPU Module and Chassis Ground. Make sure that the module’s Captured Panel Fasteners are snug but don’t over-tighten them. 3.2.4 Removal/Replacement of the Power Supply/Sequencer Module 1. If the ControlWave I/O Rack is running, place any critical control processes under manual control and shut down the unit by setting the PSSM Power Switch to the ‘O’ position. 2. Remove the Bezel Assembly (see Section 3.2.2). 3. Unplug the PSSM’s modular connectors TB1 (Power) and TB2 (Watchdog). 4. Remove the CPU Module (see Section 3.2.3). The CPU Module must be removed prior to removal/replacement of the PSSM. 5. Loosen the two Captured Panel Fasteners that secure the PSSM to the Chassis and then carefully slide the PPSM out of the front of the Chassis. 6. To replace the PSSM, the CPU Module must be removed. Carefully align the PSSM with Chassis Slot 1 and insert the unit into the Chassis. When the assembly is fully seated (PSSM Connector J1 has mated with Backplane Connector P1), turn the module’s Captured Panel Fasteners (clockwise) to secure the Power Supply/Sequencer Module to the Chassis thus establishing a low resistance path between the PSSM and Chassis Ground. Make sure that the module’s Captured Panel Fasteners are snug but don’t over-tighten them. 7. Replace the CPU Module (see Section 3.2.3) and apply power. 3-2 / Service CI-ControlWaveEXP 3.2.5 Module Hot Swapping The CPU’s Hot Swap circuitry provides for installation and removal of any or all I/O Modules while the unit is running its application load (RUN Mode). When an I/O Module is initially removed or installed, the ControlWave I/O Expansion Rack halts operation for 300 milliseconds before resuming operation from where it halted. To replace an I/O Module, follow the steps in sections 3.2.5.1 and 3.2.5.2 below. 3.2.5.1 I/O Module Hot Swap Removal 1. Shut down or place under manual control all processes associated with the I/O Module being removed. Note: Although more than one I/O Module can be removed while power is applied to the unit, the service technician must never remove or insert more than one I/O Module at a time. 2. Remove the Terminal Housing Assembly (see Figure 2-16). 3. Turn the Terminal Board’s Quarter Turn Fasteners (counterclockwise) and remove the Terminal Board Assembly (with wiring harness) from the I/O module. 4. Turn the I/O Module’s Captured Panel Fasteners (counterclockwise) until it can be removed from the Chassis. Remove the I/O Module assembly in question from the Chassis. Note: To ease I/O Module removal, reinstall the Terminal Housing Assembly and (with Terminal Door open) grasp the Terminal Handle and remove the I/O Module. 5. If not already done, remove the Terminal Board Assembly from the replacement I/O Module. 3.2.5.2 I/O Module Hot Swap Installation 1. Install the replacement I/O Module into the same I/O slot that the I/O Module assembly in question was removed from. When the assembly is fully seated, turn the I/O Module’s Panel Fasteners (clockwise) to secure the unit to the Chassis. Check the I/O Module’s Green Status LED (see Figures 3-3 through 3-7). 2. Install the original Terminal Board Assembly (with wiring harness) onto the replacement I/O Module (turning the Quarter Turn Fasteners (clockwise). 3. Replace the Terminal Housing Assembly. 4. Remove from manual control any processes associated with the I/O Module. 3.3 TROUBLESHOOTING TIPS 3.3.1 Power Supply/Sequencer Module (PSSM) Voltage Checks One or two bulk power sources can be connected to the PSSM. PPSM connector TB2 provides 5 input terminal connections for bulk power (see Figure 3-1): TB2-1 = TB2-2 = TB2-3 = TB2-4 = TB2-5 = (+VIN) (+10.6V to +20V dc for +12V supply) (+20.7V to +30V dc for +24V supply) (+VINF) Connected to TB2-1 or separate +9Vdc to +30Vdc supply (-VIN) (1st Supply Ground) (-VINF) (2nd Supply Ground) Internally connected to TB2-3 Chassis Ground - CHASSIS (;) Bulk supply voltages can be checked at TB2 using a voltmeter or multimeter. PPSM’s are factory configured for use with a nominal 12Vdc or 24Vdc bulk power supply. The maximum and minimum input power switchpoints can be tested with the use of a Variable dc Power Supply connected between TB2-1 (+) and TB2-3 (-). By increasing the input CI-ControlWaveEXP Service / 3-3 voltage (starting at +10.6Vdc or +20.7Vdc) for +12V or +24V units respectively, you can determine the point at which the unit will turn on, i.e., the point at which the green PWRGOOD LED on the PSSM comes ON (Vt+). By decreasing the input voltage (starting at +20Vdc or +30Vdc) for +12V and +24V units respectively, you can determine the point at which the unit turns off, i.e., the point at which the green PWRGOOD LED on the PSSM goes OFF (Vt-). If the value of the bulk power supply’s +12Vdc or +24Vdc output approaches the value of Vt+ or Vt- it should be replaced by one with the correct +12V or +24V output. Figure 3-1 - Power Supply/Sequencer Module’s TB1, TB2 & LED Designations 3.3.2 LED Checks All ControlWave Modules contain light emitting diodes (LEDs) that provide operational and diagnostic functions. A brief synopsis of the individual module LEDs is provided as follows: PSSM: CPUB: 1 MC LED, 1 PWRFAIL LED & 1 PWRGOOD LED 2 LEDs per Comm. Port = 4, 2 LEDs per Ethernet Port = 2 1 Idle LED, 1 Watchdog LED & the Port 80 Display Assembly SCB: 2 LEDs per Comm. Port = 8 AIM: 1 Status LED plus 32 AI LEDs (i.e., 2 LEDs per AI @ 16 AI) AOM: 1 FAIL LED & 1 GOOD LED DIM: 1 Status LED plus 32 DI LEDs (i.e., 1 LED per DI @ 32 DI) DOM: 1 Status LED plus 32 DO LEDs (i.e., 1 LED per DO @ 32 DO) UDIM: 1 Status LED plus 12 UI LEDs (i.e., 1 LED per UDI @ 12 UDI) ControlWave Module LED designations and functions are provided in Table 3-1. 3-4 / Service CI-ControlWaveEXP Table 3-1 - LED Assignment PSSM PSSM PSSM CPUB CPUB CPUB CPUB CPUB CPUB CPUB CPUB CPUB SCB SCB SCB SCB SCB SCB SCB SCB MC PWRFAIL PWRGOOD CR1 - WATCHDOG CR2 - IDLE CR1 - COMM 1 RX CR1 - COMM 1 TX CR1 - COMM 2 RX CR1 - COMM 2 TX CR2 - ENET Port 1 CR2 - ENET Port 1 PORT 80 DISPLAY CR1 - COMM 3 RX CR1 - COMM 3 TX CR1 - COMM 4 RX CR1 - COMM 4 TX CR2 - COMM 5 RX CR2 - COMM 5 TX CR2 - COMM 6 RX CR2 - COMM 6 TX LED Color Red Red Green Red Red Red Red Red Red Red/Green Red/Green Red LED Red Red Red Red Red Red Red Red AIM AI Bd. Status Red/Green Module LED Name AOM AOM RANGE (16 LEDs) (1 Per Point) RANGE (16 LEDs) (1 Per Point) AO Bd. Status Fail AO Bd. Status Pass DIM DI Bd. Status Red/Green DIM INPUT (32 LEDs) (1 Per Point) Red DOM DO Bd. Status Red/Green DOM OUTPUT (32 LEDs) (1 Per Point) Red AIM AIM Red Green Red *** Green *** Function ON 2msec after PWR_FAIL goes low * ON = Bulk or Regulated Power out of Specs. * ON = Normal operation - all supplies O.K. * ON = Watchdog Condition - OFF = Normal ON = Idle ON = RX Activity (Top-Left - see Fig 3-2) ON = TX Activity (Top-Right -see Fig 3-2) ON = RX Activity (Bottom-Left - see Fig 3-2) ON = TX Activity (Bottom-Right -see Fig 3-2) ON Green = Receiving Data (Left -see Fig 3-2) ON Red = Transmitting Data (Right - see Fig 3-2) LED Matrix Status Codes (see Fig 3-2) ** ON = RX Activity (Top-Left - see Fig 3-2) ON = TX Activity (Top-Right -see Fig 3-2) ON = RX Activity (Bottom-Left - see Fig 3-2) ON = TX Activity (Bottom-Right -see Fig 3-2) ON = RX Activity (Top-Left - see Fig 3-2) ON = TX Activity (Top-Right -see Fig 3-2) ON = RX Activity (Bottom-Left - see Fig 3-2) ON = TX Activity (Bottom-Right -see Fig 3-2) ON Red = Fail State/Bd. not recognized ON Green = Normal State (see Fig 3-3) LED ON = Overrange or Underrange condition (see Fig 3-3) LED ON = In-range condition (see Fig 3-3) LED ON = AI Bd. Fail State/Bd. not recognized LED ON = AI Bd. Normal or O.K. State ON RED = DI Bd. Fail State/BD. not recognized ON Green = DI Bd. Normal State (see Fig. 3-5) LED ON = Input is present LED OFF = Input is not present (see Fig 3-5) ON RED = Fail State/Module not recognized ON Green = Normal State (see Fig 3-6) LED ON = Output is ON (see Fig 3-6) ON RED = UI Bd. Fail State/Bd. not recognized On Green = UI Bd. Normal or O.K. State INPUT (12 LEDs) LED ON = Input activity on input is present UDIM Red (1 Per Point) LED OFF = No activity on input (see Fig 3-7) * = see Figure 3-1, ** = see Sections 2.4.2 & 3.4.4, *** = see Figure 3-4 UDIM UDI Bd. Status Fail CI-ControlWaveEXP Red/Green Service / 3-5 Figure 3-2 - CPU Module Port & LED Designations Figure 3-3 - Analog Input (AI) Module LED Designations 3-6 / Service CI-ControlWaveEXP Figure 3-4 - Analog Output (AO) Module LED Designations Figure 3-5 - Digital Input (DI) Module LED Designations CI-ControlWaveEXP Service / 3-7 Figure 3-6 - Digital Output (DO) Module LED Designations Figure 3-7 - Universal Digital Input (UDI) Module LED Designations 3-8 / Service CI-ControlWaveEXP 3.3.3 Wiring/Signal Checks Check I/O Field Wires at the Card Edge Terminal Blocks and at the field device. Check wiring for continuity, shorts & opens. Check I/O signals at their respective Terminal Blocks (see Table 3-2). Table 3-2 - I/O Field Wiring - Terminal Block Reference List I/O Subsystem Discrete Inputs Discrete Outputs Analog Inputs Analog Output Universal Inputs Watchdog Ckt. Figures 2-19 through 2-23 2-24 through 2-27 2-28 through 2-33 2-34 through 2-37 2-38 through 2-41 2-44A & 2-44B Notes See Section 2.3.4.4 See Section 2.3.4.5 See Section 2.3.4.6 See Section 2.3.4.7 See Section 2.3.4.8 See Section 2.3.5.3 3.4 GENERAL SERVICE NOTES Certain questions or situations frequently arise when servicing the BBI Controllers. Some items of interest are provided in Sections 3.4.1 through 3.4.4. 3.4.1 Extent of Field Repairs Field repairs to ControlWave I/O Expansion Racks are strictly limited to the replacement of complete modules. ControlWave Modules are sealed and employ a tamper indicator. Disassembly of a ControlWave Module constitutes tampering and will violate the warranty. Defective ControlWave Chassis or Modules must be returned to Bristol Babcock for authorized service. 3.4.2 Disconnecting RAM Battery The ControlWave I/O Expansion Rack’s Lithium RAM battery can be replaced while power is on. Upon power-up, the unit will recover its last I/O states. The battery may be disabled by setting CPU Switch SW3 position 4 to the OFF position. 3.4.3 Port 80 Display POST Checks At start-up, by applying power or by depressing the momentary contact (RESET) switch, the resident BIOS will initiate and test the hardware; this process is referred to as POST, i.e., Power On Self Test. The status of the POST progress (typically too fast to discern) is posted to the CPU Module’s Port 80 Display. Successful POST completion is indicated with an 86 on the port 80 Display if the unit is in Recovery Mode. Detection of a fault will be indicated by a 2-digit code on the Port 80 Display (see Table 3-3 and Table 2-11). CI-ControlWaveEXP Service / 3-9 Table 3-3 - Port 80 POST Status Codes Hex Code 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 3-10 / Service Definition POST beginning. CPU register test about to start. NMIs are disabled; delay starts. power-on delay finished. kbd BAT done; reading kbd SYS bit. disabling shadowing & cache. calcing ROM cksum, wait kbd ctrllr. cksum okay, kbd ctrllr free. verifying BAT cmd to kbd ctrllr. N/A N/A issuing pin 23, 24 blocking & unblocking. issuing kbd ctrllr NOP cmd next. testing CMOS RAM shutdown register. checking CMOS cksum, updating DIAG byte. initializing CMOS (if req’d every boot). init CMOS status reg for date/time. disabling DMA, interrupt ctrllrs. disabling Port B, disabling video display. init board, start auto-mem detect. starting timer tests. testing 8254 T2, for spkr, part B. testing 8254 T1, for refresh. testing 8254 To, for 18.2 Hz. starting memory refresh. testing memory refresh. testing 15usec refresh ON/OFF time. testing base 64KB memory. testing data lines. testing address lines. testing parity (toggling). base 64KB mem read/write test. system init before vector table init. init vector table. reading 8042 for turbo switch setting. initiating turbo data. any init after vector table init is next. N/A N/A toggle parity before optional video ROM. N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A check ROM BIOS data area at seg 40h. setting cursor for power-on msg. CI-ControlWaveEXP Table 3-3 - Port 80 POST Status Codes (Continued) Hex Code 37 38 39 3A 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 80 81 82 83 84 85 86 87 88 89 8A 8B 8C CI-ControlWaveEXP Definition displaying power-on message. save cursor position. display BIOS ident. String. display “Hit <DEL> to …” msg. preparing vm test. vrfy from display. preparing descriptor tables. enter virtual mode for memory test. enable inits for diagnostics mode. init data for checking wraparound at 0:0. checking for wrap, find total memory size. write extended memory test patterns. write conventional memory test patterns. finding low memory size from patterns. finding high memory size from patterns. check ROM BIOS data area again. check for <DEL>, clear low mem for soft reset. clearing ext mem for soft reset. saving memory size. on cold boot, display 1st 64KB memtest. on cold boot, test all of low memory. adjust memsize for 1K usage. on cold boot, test high memory. prepare for shutdown to real-mode. saved regs & memsize, entering real-mode. shutdown successful, restoring codepath. disabling A20 line. checking ROM BIOS data area again. checking ROM BIOS data area some more. clear the “Hit <DEL>” message. test DMA page register. verify from display memory (???). test DMA0 base register. test DMA1 base register. checking ROM BIOS data area again. checking ROM BIOS data area some more. programming DMA ctrllrs 0 & 1 initializing INT ctrllrs 0 & 1. N/A N/A N/A N/A N/A check for memsize mismatch. check for pswd or bypass setup. pswd checked. Do pgming before setup. call the setup module. N/A display power-on screen message. display “Wait…” message. N/A N/A Service / 3-11 Table 3-3 - Port 80 POST Status Codes (Continued) Hex Code 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 B0 B1 B2 B3 Definition N/A check floppy disks. N/A N/A N/A N/A N/A setting base & ext mem sizes. N/A N/A N/A processing after extension returns. configuring timer data area, printer base addr. configuring serial port base addrs. initialization before coprocessor test. initializing the coprocessor. processing after coprocessor initialized. N/A N/A kbd ID flag reset. do cache memory test. display any soft errors. N/A program memory wait states. N/A enable parity and NMIs. N/A N/A N/A N/A test low memory exhaustively. test extended memory exhaustively. N/A 3.5 WINDIAG DIAGNOSTICS Bristol’s WINDIAG Software is a diagnostic tool used for testing ControlWave I/O Modules, CPU memory, communications ports, etc., for proper performance. The ControlWave I/O Expansion Rack must be communicating with a PC equipped with Bristol’s WINDIAG program. CPU Module configuration switch SW1-8 must be set to the OFF (Closed) position to enable diagnostics. Communication between the ControlWave I/O Expansion Rack (with/without application loaded) and the PC can be made via a Local or Network Port with the following restrictions: • CPU Board Switch SW1-8 must be OFF (closed) to run the WINDIAG program. Setting SW1-8 OFF will prevent the ‘Boot Project’ from running and will place the unit into diagnostic mode. • Any ControlWave I/O Equipment Rack serial communication port COM1 through COM6 can be connected to the PC (PEI) provided their port speeds match. Most PCs have a COM1 port (typically RS-232 and defaulted to 9600 bps operation). 3-12 / Service CI-ControlWaveEXP • Communication port COM1 is only forced to 9600 bps operation when CPU Switches SW1-3 and SW1-8 have both been set OFF (closed). COM1 can also be set to 9600 bps operation via user defined Soft Switches. • Setting CPU Board Switches SW1-3 and SW1-8 OFF (closed) prevents the ‘Boot Project’ from running, places the unit into diagnostic mode and forces communication ports COM1 through COM6 to operate at 9600 baud. COM1: From the factory, COM1 defaults to 9600 bps (RS-232) using the Internet Point to Point Protocol (PPP). Note: ControlWave Port COM1 will be configured for RS-232 operation (at 9600 baud) by setting CPU Switches SW1-3 and SW1-8 OFF. To test COM1 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. Connection to a PC requires the use of an RS-232 “Null Modem” cable (see Figure 2-9). COM2: When factory set for RS-232 or RS-485 operation, COM2 defaults to 9600 baud, 8bits, no parity, 1 stop bit, BSAP/ControlWave Designer protocol operation. To test COM2 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. In lieu of the use of COM1, an RS232 “Null Modem” cable (see Figure 2-9A) can be connected between COM2 and the PC (typically COM1) or an RS-485 cable (see Tables 2-4 & 2-6) can be connected between COM2 and the PC’s RS-485 Port. If the PC is equipped with an RS-232 Port that utilizes an RJ-45 jack, use either a special “Null Modem” cable equipped with an RJ-45 male plug and wired like the null modem cable of Figure 2-9A, or use Bristol “Null Modem” cable P/N 39284301-3 connected to a Bristol “RJ-45 to DB9 Adapter” cable P/N 392844-01-0 (see Figures 2-9A & 2-9B), to interconnect the PC to COM2. If RS-485 communications is required an RS-485 cable can be assembled using the connections provided in Tables 2-4 and 2-6. COM3: Factory set for RS-485 operation, COM3 defaults to 9600 baud, 8-bits, no parity, 1 stop bit, BSAP/ControlWave Designer protocol operation. To test COM3 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. In lieu of the use of COM1, an RS-485 cable (see Tables 2-5 & 2-6) can be connected between COM3 and the PC’s RS-485 Port. COM4: Factory set for RS-485 operation, COM4 defaults to 9600 baud, 8-bits, no parity, 1 stop bit, BSAP/ControlWave Designer protocol operation. To test COM4 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. In lieu of the use of COM1, an RS-485 cable (see Tables 2-4 & 2-6) can be connected between COM4 and the PC’s RS-485 Port. COM5: RS-232 Port COM5 defaults to 9600 baud, 8-bits, no parity, 1 stop bit, BSAP/ControlWave Designer protocol operation. To test COM5 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. In lieu of the use of COM1, an RS-232 “Null Modem” cable (see Figure 2-9) can be connected between COM5 and the PC (typically COM1). If the PC is equipped with an RS-232 Port that utilizes an RJ-45 jack, use either a special “Null Modem” cable equipped with RJ-45 male plugs and wired like the null modem cable of Figure 2-9A, or use Bristol “Null Modem” cable P/N 392843CI-ControlWaveEXP Service / 3-13 01-3 connected to two Bristol “RJ45 to DB9 Adapter” cables P/N 392844-01-0 (see Figures 2-9A & 2-9B), to interconnect the PC to COM5. COM6: RS-232 Port COM6 defaults to 9600 baud, 8-bits, no parity, 1 stop bit, BSAP/ControlWave Designer protocol operation. To test COM6 using the WINDIAG program, it must not otherwise be in use and CPU Switch SW1-8 must be set to the OFF position. In lieu of the use of COM1, an RS-232 “Null Modem” cable (see Figure 2-9) can be connected between COM6 and the PC (typically COM1). If the PC is equipped with an RS-232 Port that utilizes an RJ-45 jack, use either a special “Null Modem” cable equipped with RJ-45 male plugs and wired like the null modem cable of Figure 2-9A, or use Bristol “Null Modem” cable P/N 39284301-3 connected to two Bristol “RJ45 to DB9 Adapter” cables P/N 392844-01-0 (see Figures 2-9A & 2-9B), to interconnect the PC to COM6. Others: The Ethernet Port can be connected directly or via a network to a PC equipped with an Ethernet Port (see Figures 2-7, and 2-11 through 2-14). If not configured with an address, the ControlWave uses DHCP (by default) to obtain an IP address. To use the WINDIAG program place any critical process (associated with the ControlWave I/O Expansion Rack in question) under manual control. WINDIAG cannot be run while the ControlWave I/O Expansion Rack is running. Set the CPU Modules Switches SW1-3 and SW1-8 to the OFF (closed) position. Perform steps 1 through 6 below. 1. Start the OpenBSI NetView Program. A menu similar to Figure 3-8 will appear. 2. To start the WINDIAG program, go to the Start Program’s menu, select OpenBSI Tools, then select Utilities Programs and then select Diagnostics. 3. Once WINDIAG has been entered, the Main Diagnostics Menu of Figure 3-9 will appear. 4. Select the module to be tested. Enter any prompted parameters (slot #, etc.). WINDIAG will perform the diagnostics and display pass/fail results. 5. After all diagnostic testing has been performed, exit the WINDIAG program and then exit the Netview Program if there aren’t any other ControlWave I/O Expansion Racks to be tested. When you close the Netview program you will be prompted as to whether or not you want to close the OpenBSI program; select Yes. 6. Set CPU Switch SW1-8 to the ON (Open) position. The ControlWave I/O Equipment Rack should resume normal operation. 3.5.1 Diagnostics Using WINDIAG All Controllers Modules except the Power Supply/Sequencer Module can be tested using the WINDIAG program. From WINDIAG’s Main Diagnostics Menu (see Figure 3-9) the following diagnostic tests can be performed: CPU & Peripherals Diagnostic: PROM/RAM Diagnostic: Communications Diagnostic: Ethernet Diagnostic: Analog Output Diagnostic: Analog Input Diagnostic: 3-14 / Service Checks the CPU Module (except for RAM & PROM). Checks the CPU’s RAM and PROM hardware. Checks Comm. Ports 1 through 6 - The External loopback tests require the use of a loop-back plug. Checks Ethernet Port 1 - The Loop-back Out Twisted Pair tests require the use of a loop-back plug. Checks the Analog Output Module. Checks the Analog Input Module. CI-ControlWaveEXP Discrete I/O Diagnostic: High Speed Counter Diagnostic: Checks the DI Module and/or the DO Module. Checks the Universal Digital Input Module. Figure 3-8 - Netview Startup Menu - Example with Multiple Networks Figure 3-9 - WINDIAG Main Diagnostics Menu CI-ControlWaveEXP Service / 3-15 3.5.1.1 Communications Diagnostic Port Loop-back Test WINDIAG’s Communications Diagnostic Menu (see Figure 3-11) provides for selection of the communication port to be tested (1 or 2). Depending on the type of network (RS-232 or RS-485) and the port in question, a special loop-back plug is required as follows: Ports 1, 2 and 4 set-up for RS-232, use a 9-pin female D-type loop-back plug (see Fig. 3-10). Ports 2 and 4 set-up for RS-485, use a 9-pin female D-type loop-back plug (see Fig. 3-12). Port 3 set-up for RS-485, use an 8-pin male RJ-45 loop-back plug (see Fig. 3-12). Ports 5 and 6 set-up for RS-232, use an 8-pin male JR-45 loop-back plug (see Fig. 3-10). 1 1 = DCD 4 = RTS 6 = CTS 7 = DTR 3 = RXD 5 = TXD 2 4 = DTR 5 7 3 = TXD 2 = RXD 8 = CTS 7 = RTS 1 = DCD Figure 3-10 - RS-232 Loop-back Plugs This group of tests verifies the correct operation of the Communication Interface. COM1 through COM6 can be tested with this diagnostic. The ControlWave I/O Expansion Rack communication port that is connected to the PC (local or network and used for running these tests) can’t be tested until diagnostics has been established via one of the other ports, i.e., to test all ControlWave I/O Expansion Rack communication ports (via WINDIAG), communications with the PC will have to be established twice (each time via a different port). It should be noted that the ControlWave I/O Expansion Rack communication port that is connected to the PC (RS-232, RS-485 or Ethernet) must be good for WINDIAG to run the Communications Diagnostics. Figure 3-11 - WINDIAG’s Communications Diagnostic Menu 3-16 / Service CI-ControlWaveEXP 3.5.1.2 Serial Communications Port External Loop-back Test Procedure 1. Connect an external loop-back plug to the CPU Port to be tested, i.e., J1 of CPU for Port 1, J2 of CPU for Port 2 or J1 through J4 of the SCB for Ports 3 through 6 respectively (see Figures 3-10 through 3-12). 2. Type "1," "2," "3," "4," "5" or "6" for the port to test. 3. Set baud rate to test to 9600 baud or ALL ASYNC and the number of passes to 5. 4. Click on RUN button next to External loop-back. Test responses: a) Success - All sections of test passed b) Failure - TXD RXD Failure - CTS RTS Failure Execution time < 5 sec. Figure 3-12 - RS-485 Loop-back Plugs 3.5.1.3 Ethernet Diagnostic Port Loop-back Test WINDIAG’s Ethernet Diagnostic Menu (see Figure 3-14) provides for selection of the Ethernet communication port to be tested. A special loop-back plug is required to perform the Ethernet loop-back test (see Figure 3-13). Figure 3-13 - RJ-45 Ethernet Loop-back Plug CI-ControlWaveEXP Service / 3-17 Figure 3-14 - WINDIAG’s Ethernet Diagnostic Menu If the ControlWave I/O Expansion Rack Ethernet port is connected to the PC (and used for running these tests), it can’t be tested until diagnostics has been established via one of the other ports, i.e., to test all ControlWave I/O Expansion Rack communication ports (via WINDIAG), communications with the PC will have to be established at least twice (each time via a different port. It should be noted that the ControlWave I/O Expansion Rack communication port that is connected to the PC (RS-232, RS-485 or Ethernet) must be good for WINDIAG to run the Communications Diagnostics. This test configures the Ethernet to transmit and receive via the twisted pair port. Test frames are transmitted and compared against received frames. 3-18 / Service CI-ControlWaveEXP 3.5.1.4 Ethernet Port 1 External Loop-back Test Procedure 1. Connect an external RJ-45 Ethernet loop-back plug (see Figure 3-13) into the Ethernet Port to be tested, i.e., J3 of CPU for Port 1. 2. Type "1" for the port to test. 3. Click on the "RUN" button next to the Loop-back out twisted pair test. 4. Click on RUN button next to External loop-back. • Test responses: a) Success - All sections of test passed b) Xmit Error c) Rx Error d) Buffer Compare Failure 3.6 CORE UPDUMP In some cases a copy of the contents of SRAM can be uploaded to a PC for evaluation by Bristol Inc. engineers. This upload is referred to as a ‘Core Updump.’ A Core Updump may be required if the ControlWave I/O Equipment Rack repeatedly enters a ‘Watchdog State’ thus ill effecting system operation. A Watchdog State is entered when the system crashes, i.e., a CPU timeout occurs due to improper software operation, a firmware glitch, etc. In some cases the Watchdog State may reoccur but may not be logically reproduced. ‘Crash Blocks’ (a function of firmware provided for watchdog troubleshooting) are stored in CPU RAM. The user can view and save the ‘Crash Blocks’ by viewing the Crash Block Statistic Web Page (see Chapter 4 of the Open BSI Technician’s Toolkit - D5087). Crash Block files should be forwarded to Bristol for evaluation. If additional information is required to evaluate the condition, a Core Updump may be requested by Bristol. Once the file generated by the Core Updump has been forwarded to Bristol, it will be evaluated and the results will be provided to the user. Follow the five steps below to perform a Core Updump. 1. Disable the Watchdog Timer by setting CPU Module Switch SW1-1 to the OFF position. 2. Wait for the error condition (typically FF on Port 80 Display). 3. Connect the ControlWave I/O Expansion Rack’s Comm. Port 1 to a PC using a Null Modem Cable (see Figure 2-9). 4. Set CPU Module Switch SW1-4 to the OFF position to enable the Core Updump feature. 5. Start the PC’s HyperTerminal Program (at 115.2 kbaud) and generate a receive using the 1KX-Modem protocol. Save the resulting Core Updump in a file to be forwarded to Bristol for evaluation. When the Core Updump has completed, set CPU Switch SW1-1 ON (Watchdog Circuit Enabled), if required. CI-ControlWaveEXP Service / 3-19 BLANK PAGE Section 4 SPECIFICATIONS 4.1 CPU, MEMORY & PROGRAM INTERFACE Processor: Intel 386EX microprocessor, 25MHz Memory: 2/4Mbyte of system FLASH 1/2Mbtye of on-board static RAM 512Kbytes FLASH Boot/Downloader in a single IC Real Time Clock: Implemented via a Dallas DS1305 Serial Alarm Real Time Clock. Features 96 bytes of nonvolatile RAM for data storage. Connectors: (see Table 4-1 and referenced Tables) Table 4-1 - CPU Module Connector Summary Ref. J1 J2 J3 J4 J5 J6 J1 J2 J3 J4 # Pins 9-pin 9-pin 8-pin 132-pin 24-pin 3-pin 8-pin 9-pin 8-pin 8-pin Function COM1 male D-sub (RS-232) COM2 male D-sub (RS-232 or RS-485) Ethernet 10/100BaseT RJ-45 I/O Bus Connector Port 80 Diagnostics Battery Connector COM3 RJ-45 (RS-485) COM4 male D-sub (RS-485) COM5 RJ-45 (RS-232) COM6 RJ-45 (RS-232) Notes see Figure 4-2 & Table 4-2 see Figure 4-2 & Table 4-3 see Figure 4-4 & Table 4-5 see Figure 4-1 Not use accessible see Figure 4-5 SCB - see Figure 4-3 & Table 4-4 SCB - see Figure 4-2 & Table 4-3 SCB - see Figure 4-3 & Table 4-4 SCB - see Figure 4-3 & Table 4-4 Figure 4-1 - Power Supply Bd., CPU Bd. & I/O Bds. I/O Bus Connectors Looking into Board Connectors CI-ControlWaveEXP Specifications / 4-1 Figure 4-2 - DB9 9-Pin Connector Associated with COM1, COM2 & COM4 Table 4-2 - CPU Board Connector J1 (COM1) Pin Assignment Pin # 1 2 3 4 5 6 7 8 9 Signal RS-232 RXD TXD DTR GND RTS - Description: RS-232 Signals N/A Receive Data - Input Transmit Data - Output Data Terminal Ready Output Signal/Power Ground N/A Request To Send - Output N/A N/A - Table 4-3 - CPU Bd. Connector J2 (COM2) & SCB Connector J2 (COM4) Pin Assignments Pin # 1 2 3 4 5 6 7 8 9 Signal RS-232 DCD RXD TXD DTR GND DSR RTS CTS - COM2 Description: RS-232 Signals Data Carrier Detect Input Receive Data Input Transmit Data Output Data Terminal Ready Output Signal/Power Ground Data Set Ready Input Request To Send Output Clear To Send Input Not Used Signal RS-485 RXDTXDTXD+ ISOGND RXD+ COM2/4 Description: RS-485 Signals N/A Receive Data - Input Transmit Data - Output Transmit Data + Input Isolated Ground Receive Data + Output N/A N/A N/A Table 4-4 - SCB Bd. Connector J1 (COM3), J3 (COM5) & J4 (COM6) Pin Assignments Pin # 1 2 3 4 5 6 7 8 Signal RS-232 DCD DSR RXD RTS TXD CTS DTR GND 4-2 / Specifications COM4/5 Description: RS-232 Signals Data Carrier Detect Input Data Set Ready Input Receive Data Input Request To Send Output Transmit Data Output Clear To Send Input Data Terminal Ready Output Signal/Power Ground Signal RS-485 RXD+ RXDTXDTXD+ ISOGND COM3 Description: RS-485 Signals N/A Receive Data + Input Receive Data - Input N/A Transmit Data - Output N/A Transmit Data + Output Isolated Ground CI-ControlWaveEXP 1 8 Looking into receptacle Figure 4-3 RJ-45 Connector J1, J3 & J4 Associated with COM3, COM5 & COM6 on SCB Table 4-5 - Ethernet 10/100BaseT RJ-45 Connector Pin Assignment (CPU Connector J3) Pin # 1 2 3 6 4, 5, 7 & 8 Signal Nmae TXO+ TXORXI+ RXIN/C Description: Ethernet Signals Transmit Data - Output Transmit Data - Output Receive Data - Input Receive Data - Input N/A 1 8 Looking into receptacle Figure 4-4 - RJ45 Ethernet Connector J3 = Ethernet 1 Figure 4-5 - Connector J6 - CPU Battery Header CI-ControlWaveEXP Specifications / 4-3 4.2 POWER SUPPLY/SEQUENCER MODULE 4.2.1 Input Power Specs. Note: Voltages are dc unless otherwise specified. Operating Range: TB2-1 (+VIN) LOGIC (dc) Supply +10.6V to +20.0V (+12V Input Supply) (Shutdown occurs at +10.6V nominal) +20.7V to +30.0V (+24V Input Supply) (Shutdown occurs at +20.7V nominal) TB2-2 (+VINF) FIELD (dc) Supply +9.0V to +30.0V (Bulk Input Supply) Output Voltages: Isolated +3.3V, +5V, +12V (optional) & -12V (optional) Output Current: Typical (±12V Supplies Not Used) 1.5A (Max.) @ +5V 1A (Max.) @ +3.3V 0A @ ±12V with 0A @ +3.3V 2A (Max.) @ +5V 200mA (Max.) @ +12V 200mA (Max.) @ -12V Output Ripple: With +5V @ 1A, +12V & -12V @ 200mA +5V Output: 50mV, 110mVpp @ 30V input +12V Output: 40mVpp @ 20V input -12V Output: 50mVpp @ 24V input With +5V @ 300mA, ±12V supplies OFF +5V Output: 50mV, 280mVpp Input Current: With Supply Loading of 5V @ 1.25A, +3.3V @ 1.0A, +12V & -12V @ 0mA Vin @ +12V - Iin Max. 1.62A Vin @ +24V - Iin Max. 0.80A Fusing: 10A Slow Blow 5x20mm Fuse - FIELD Supply 3A Slow Blow 5x20mm Fuse - LOGIC Supply Electrical Isolation: 500Vdc Primary to Secondary Surge Suppression: 500Vdc MOV, (PSGND) to CHASSIS 32V Transient Suppressor from +VIN to -VIN (PSGND) Meets ANSI/IEEE C37.90-1978 Terminations: Pluggable, maximum wire size is 14 gauge Shutdown: +12V PSSM: Max. ON Switchpoint = 11.11V Min. OFF Switchpoint = 10.52V 4-4 / Specifications CI-ControlWaveEXP +24V System: Max. ON Switchpoint = 22.05V Min. OFF Switchpoint = 20.49V Power Switch: MOSFET Driven by Switch connected to Gate 4.2.2 Power Supply Sequencer Specs. Signals Monitored: Switched Input Supply Voltage (+VINSWS) Isolated Output Voltages (+3.3V, +5V, +12V & -12V) Sequencer Switchpoints For Master Clear & Power Fail +12V Input Supply System Input Power. Max. ON = +11.02V Input Power Min. OFF = +10.78V +24V Input Supply System Input Power. Max. ON = +21.87V Input Power Min. OFF = +21.09V +5V Max. ON Switchpoint = +4.85V +5V Min. OFF Switchpoint = +4.75V ±12V Max. ON Switchpoint = ±11.52V ±12V Min. OFF Switchpoint = ±11.38V Sequencer Output Signals: /MC, /PWR_FAIL - Timing on power down: /MC active 2msec after /PWR_FAIL asserted. /MC, /PWR_FAIL - Timing on power up: /MC, /PWR_FAIL active for 100msec after all monitored voltage levels reach nominally good values. Hot Swap Monitor: Signals Monitored: /BDINSLT1 - /BDINSLT8, /SWS1 - /SWS8, /MC Output Signals: /IOBTRI; timing on I/O Module insertion: Active 40µs after /BDINSLTn asserted, and until 300ms after /SWSn asserted /IOBTRI; timing on I/O Module extraction: Active 40µs after /SWSn negated, and until 20ms after /BDINSLTn negated /HBIR_NMI; timing on I/O Module insertion: Active when /BDINSLTn asserted, and until 300ms after /SWSn asserted /HBIR_NMI; timing on I/O Module extraction: Active when /SWSn negated, and until 20ms after /BDINSLTn negated CI-ControlWaveEXP Specifications / 4-5 /MC1 - /MC8; timing on I/O Module insertion: Active when /BDINSLTn asserted, and until 300ms after /SWSn asserted /MC1 - /MC8; timing on I/O Module extraction: Active when /SWSn negated, and until 20ms after /BDINSLTn negated Watchdog Sequencer: Input Signals: /MC & /WDOGB Enable/ Disable: Via CPU Module Switch SW1-1 Watchdog MOSFET Switch populated: Voltage applied to VI terminal TB1-2 (switched to VO terminal (TB1-1) unless either /MC or /WDOGB is asserted; applied voltage is referenced to -VIN (PSGND) at TB2-3 4.2.3 Power Supply Connectors (see Table 4-6 and referenced Tables) Table 4-6 - Power Supply Board Connector Summary Ref. J1 TB1 TB2 # Pins 132-pin 3-pin 5-pin Function Backplane Connector Watchdog Term. Block Input Power Term. Block Notes see Figure 4-1 see Figure 4-6 & Table 4-7 see Figure 4-6 & Table 4-7 Figure 4-6 - Power Supply/Sequencer Module Connectors TB1 & TB2 Table 4-7 - Power Supply Terminal Blocks TERM. # TB1-1 TB1-2 TB1-3 TB2-1 TB2-2 TB2-3 TB2-4 TB2-5 NAME VO VI VR +VIN +VINF -VIN -VINF CHASSIS 4-6 / Specifications FUNCTION VO MOSFET Watchdog Switch Output VI MOSFET Watchdog Switch Input Redundancy Unit Control Input (Used with ControlWaveREDIO) +10.6V to +30V (dc) Input +9 to +30V (dc) Input (Field Device Power) or jumper to TB2-1 1st Supply Common 2nd Supply Common (Field Device Power) or jumper to TB2-3 Chassis Ground CI-ControlWaveEXP 4.3 BACKPLANE PCB Slots: 2, 4, or 8 I/O, 1 CPU & 1 Power Supply (Modules) Data Bus: Interrupts: 16-bit memory mapped access to I/O slave devices 1 each unique interrupts in I/O Slots 1 through 4 (IOBIRQn, where n = I/O Slot number 1, 2, 3 or 4) Power: +3.3V, +5V, +12V, -12V, PCOM Connectors: 132-pin CPCI style connectors for CPU, PSSM and I/O modules; three unique keying configurations prevent module insertion into improper slot locations (see Figures 4-1 & 4-7 & Table 4-8) Figure 4-7 - Backplane PCB Connector Assignment Table 4-8 - Backplane PCB Connector Assignment Number P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 CI-ControlWaveEXP Function Power Supply Module Intf. CPU Module Interface I/O Module #1 Interface I/O Module #2 Interface I/O Module #3 Interface I/O Module #4 Interface I/O Module #5 Interface I/O Module #6 Interface I/O Module #7 Interface I/O Module #8 Interface Reference See Figures 4-1 & 4-7 See Figures 4-1 & 4-7 See Figures 4-1 & 4-7 See Figures 4-1 & 4-7 See Figures 4-1 & 4-7 See Figures 4-1 & 4-7 See Figures 4-1 & 4-7 See Figures 4-1 & 4-7 See Figures 4-1 & 4-7 See Figures 4-1 & 4-7 Specifications / 4-7 4.4 COMMUNICATION PORTS Connector/Port: CPU Bd. J1 - 9-Pin D-Type - COM1 (RS-232) CPU Bd. J2 - 9-Pin D-Type -COM2 (RS-232 or RS-485) CPU Bd. J3 - 8-Pin RJ-45 - #1 -Ethernet 10/100BaseT SCB Bd. J1 - 8-Pin RJ-45 - COM3 (RS-485) SCB Bd. J2 - 9-Pin D-Type - COM4 (RS-485) SCB Bd. J3 - 8-Pin RJ-45 -COM5 (RS-232) SCB Bd. J4 - 8-Pin RJ-45 -COM6 (RS-232) Baud Rate: 300 to 9600 (bps) for RS-232 or RS-485 10/100M (bps) for Ethernet 4.5 INPUT/OUTPUT MODULE SPECIFICATIONS 4.5.1 Analog Inputs Number of Inputs: 16/8 Analog Inputs (Current Loop type input module) 16/8 Analog Inputs (Voltage type input module) Input Type: Isolated Voltage Input: 1-5 Vdc Internally Sourced Current Loop: 4-20mA Accuracy: 0.1% of Span @ +25ºC (+77ºF) 0.2% of Span @ -20ºC to +70ºC (-4ºF to +158ºF) 0.3% of Span @ -40ºC to +70ºC (-40ºF to 158ºF) A/D Resolution: 14 Bits Isolated Voltage/Current Common Mode Range: 31Vdc referenced to Isolated Common (for 1-5 Vdc) Powered Current Loop Common Mode Range: 0V referenced to Isolated Common Input Filtering: 300 msec to 99.9% of input value Channel Settling Time: 680msec Conversion Time: 25msec On-board Reference: 1V, 5V Surge Suppression: 31Vdc Transorb across input signals and (-) input to CHASSIS. 500Vdc MOV isolated common to chassis. Meets ANSI/IEEE C37.90-1978 Terminations: Pluggable - Max. wire size is 14 gauge Bus Access: 16 Bits Wide Status Indication: 32/16 LEDs (two per point) plus 1 Status LED 4-8 / Specifications CI-ControlWaveEXP Power Consumption: 4-20 mA AI Module: 136 mA Max. @ 5Vdc (Full Population, 16 LEDs ON) 121.3 mA Max. @ 5Vdc (Half Population, 8 LEDs ON) IIN (24V) = 52mA + 25mA/point (when point is @ 20mA) IIN (12V) = 52mA + 50mA/point (when point is @ 20mA) 1-5 V AI Module: (@ 5Vdc) 128 mA Max. @ -5%/+105% (Full Pop., 16 LEDs ON) 115 mA Max. @ -5%/+105% (Half Pop., 8 LEDs ON) 4.5.2 Digital Inputs Number of Inputs: 32/16 Input Voltage Range: 24V Input Filtering: 30 milliseconds Input Configuration: Internally Sourced or Externally Sourced (Factory Configured) Input Current: 5mA nominal ‘0’ State Voltage: ‘1’ State Voltage: below 10% of nominal input voltage above 80% of nominal input voltage Bus Access: Sixteen Bits Wide (IOBD15 - IOBD0) Electrical Isolation: 1500Vdc Surge Suppression: 500Vdc MOV to CHASSIS 31Vdc Transorb across input and to FIELD COMMON Meets ANSI/IEEE C37.90-1978 Terminations: Pluggable, maximum wire size is 14 gauge Status Indication: 32/16 LEDs (one per point) plus 1 Status LED Power Consumption: 8 mA Max. @ 5Vdc (All Inputs OFF) 98 mA Max. @ 5Vdc (Full Pop., All DI ON, 32 LEDs ON) 43 mA Max. @ 5Vdc (Full Pop., All DI ON, 32 LEDs OFF) 53 mA Max. @ 5Vdc (Half Pop., All DI ON, 16 LEDs ON) IIN (24V) = 30mA + 4.8mA/point (when point is configured for Dry Contact - Internally Sourced operation) IIN (12V) = 27mA + 9.5mA/point (when point is configured for Dry Contact - Internally Sourced operation) 4.5.3 Analog Outputs Number of Outputs: 8/4 Output Configurations: Current Output - 4-20mA Voltage Output - 1-5V (from daughter board) CI-ControlWaveEXP Specifications / 4-9 Resolution: 12 bits Underrange/Overrange: -5/+105 % Accuracy: Current Output: 0.1% of Span @ +25ºC (+77ºF) 0.2% of Span @ -20ºC to +70ºC (-4ºF to +158ºF) 0.3% of Span @ -40ºC to +70ºC (-40ºF to 158ºF) Voltage Output Compliance (Iloadmax = 5mA): (see Note1 & Note2) 0.1% of Span + X @ +25ºC (+77ºF) 0.2% of Span + X @ -20ºC to +70ºC (-4ºF to +158ºF) 0.3% of Span + X @ -40ºC to +70ºC (-40ºF to 158ºF) where X = [(5 ohms x Iload)/4.4V x 100] Note1: Note2: Does not include error due to inductors 5 ohm uncompensated series resistance with Inductors Surge Suppression: 500Vdc MOV to CHASSIS 31Vdc Transorb between signal and isolated ground Meets ANSI/IEEE C37.90-1978 Settling time to .1%: 1 millisecond Bus Access: Sixteen Bits Wide Terminations: Pluggable, maximum wire size is 14 gauge Status Indication: 2 LEDs (Fail & Good) Power Consumption: All AOs @ -5% = 60mA Max. @ 5Vdc (for Full & Half Populated AO Module) All AOs @ +105% = 67mA Max. @ 5Vdc (for Full & Half Populated AO Module) 4-20 mA AO Module: IIN (24V) = 27mA + 24mA/point (when point is @ 20mA) IIN (12V) = 22.5mA + 47mA/point (when point is @ 20mA) 1-5V AO Module: IIN (24V) = 27mA + 24mA/point + 6.19mA/point (when point is @ 5mA) IIN (12V) = 22.5mA + 47mA/point + 12.5mA/point (when point is @ 5mA) 4.5.4 Digital Outputs Number of Outputs: 32/16 Output Type: Open Source (10- 31 Vdc - External Power) 4-10 / Specifications CI-ControlWaveEXP Surge Suppression: 500Vdc MOV to CHASSIS 31Vdc Transorb across output Meets ANSI/IEEE C37.90-1978 Max. Operating Voltage: 31Vdc Max. Operating Frequency: 20 Hz Current Sink: 500mA Maximum Electrical Isolation: 1500Vdc Terminations: Pluggable, maximum wire size is 14 gauge Bus Access: Sixteen Bits Wide Status Indication: 32/16 LEDs (one per point) plus 1 Status LED Power Consumption: 10 mA Max. @ 5Vdc (All DOs OFF) 90 mA Max. @ 5Vdc (Full Populated DO Module, All DOs ON, 32 LEDs OFF) 143 mA Max. @ 5Vdc (Full Populated DO Module, All DOs ON, 32 LEDs ON) 76 mA Max. @ 5Vdc (Half Populated DO Module, All DOs ON, 16 LEDs ON) 4.5.5 Universal Digital Inputs Number of Inputs: 12/6 Input Voltage Range: 24V Input Frequency: 10KHz Max. Input filtering: Software Selectable: 1 msec (±0.5 msec) for Low Speed Counter 30 msec for Contact Closure Hardware Set: 20 usec for High Speed Counter Input configuration: Hardware: Factory Configured Set/Reset inputs, for debounce of contact closure Software: Interrupt on change of state (software configurable) Monitor input status Input current: 5mA +/- 10% ‘1’ State Voltage: ‘0’ State Voltage: 90% of input voltage range 10% of input voltage range Bus Access: Sixteen Bits Wide CI-ControlWaveEXP Specifications / 4-11 Max. Accumulator Value: 65536 Electrical isolation: 1500Vdc to system logic 500Vdc to CHASSIS Surge Suppression: 31Vdc Transorb across input and to FIELD COMMOM Meets ANSI/IEEE C37.90-1978 Terminations: Pluggable, max wire size is 14 gauge Status Indication: 12/6 LEDs (one per point) plus 1 Status LED Power Consumption: 21 mA Max. @ 5Vdc (All Inputs OFF) 69 mA Max. @ 5Vdc (Full Populated UDI Module, All UDIs ON, 12 LEDs OFF) 91 mA Max. @ 5Vdc (Full Populated UDI Module, All UDIs ON, 12 LEDs ON) 56 mA Max. @ 5Vdc (Half Populated UDI Module, All UDIs ON, 6 LEDs ON) 4.6 ENVIRONMENTAL SPECIFICATIONS Temperature: Operating: Storage: -40 to +158 °F (-40 to +70 °C) -40 to +158 °F (-40 to +70 °C) Relative Humidity: 0-95% Non-condensing Vibration: 1g for 10 - 150 Hz .5g for 150 - 2000 Hz Shock: 30g (11 msec duration) 50g (11 msec duration) RFI Susceptibility: In conformity with the following standards: ENV 50140 Radio-frequency electromagnetic field, Amplitude modulated ENV 50204 Radio-frequency electromagnetic field, Pulse modulated 4.7 DIMENSIONS 2 I/O Chassis 4 I/O Chassis 8 I/O Chassis ControlWaveEXP Installation 4-12 / Specifications see Figure 4-8 see Figure 4-9 see Figure 4-10 see Figure 4-11 CI-ControlWaveEXP Figure 4-8 - 2I/O ControlWave I/O Expansion Rack Chassis Assembly CI-ControlWaveEXP Specifications / 4-13 Figure 4-9 - 4I/O ControlWave I/O Expansion Rack Chassis Assembly 4-14 / Specifications CI-ControlWaveEXP Figure 4-10 - 8I/O ControlWave I/O Expansion Rack Chassis Assembly CI-ControlWaveEXP Specifications / 4-15 Figure 4-11 - ControlWave I/O Expansion Rack Installation Drawing 4-16 / Specifications CI-ControlWaveEXP ControlWave I/O Expansion Rack Special Instructions for Class I, Division 2 Hazardous Locations 1. The Bristol, Inc. ControlWave I/O Expansion Rack is listed by Underwriters Laboratories (UL) as nonincendive and is suitable for use in Class I, Division 2, Groups A, B, C and D hazardous locations and non-hazardous locations only. Read this document carefully before installing a nonincendive Bristol ControlWave I/O Expansion Rack. In the event of a conflict between the ControlWave Instruction Manual (CIControlWaveEXP) and this document, always follow the instructions in this document. 2. All power and I/O wiring must be performed in accordance with Class I, Division 2 wiring methods as defined in Article 501-4 (b) of the National Electrical Code, NFPA 70, for installations within the United States, or as specified in Section 18-152 of the Canadian Electrical Code for installation in Canada. 3. WARNING: EXPLOSION HAZARD - Substitution of components may impair suitability for use in Class I, Division 2 environments. 4. WARNING: EXPLOSION HAZARD - When situated in a hazardous location, turn off power before servicing/replacing the unit and before installing or removing I/O wiring. 5. WARNING: EXPLOSION HAZARD - Do Not disconnect equipment unless the power has been switched off or the area is known to be nonhazardous. 10/11/06 Appendix A, Document CI-ControlWaveEXP Page 1 of 1 BLANK PAGE ControlWave I/O Expansion Rack Open Modbus Interface Information Open Modbus Interface The Open Modbus Interface allows access to areas of memory in the ControlWave I/O Expansion Rack serving as Modbus registers and coils. In order to determine which coil / register numbers to reference in your Modbus commands, please refer to the tables on the following pages. IMPORTANT By default, registers are transmitted upper byte or upper word (upper byte within a word) first. If, because of the requirements of your protocol, or device, you need to change the order of transmission, please follow the instructions at the end of this section. System Data Range: 1-100 Board Status Hot Card Replacement in progress Battery Status Board Type Register (2 byte - transmitted upper byte first) Board 1 1 17 Board 2 2 17 Board 3 3 17 Board 4 4 17 Board 5 5 17 Board 6 6 17 Board 7 7 17 Board 8 8 17 18 1 18 2 18 3 18 4 18 5 18 6 18 7 18 8 Digital Data Range: 101-420 (40 per board) Example: To read DO output coil 5 on board 7, find DO output coils in the first column of the table, below, then move along that row until you reach the board 7 column to determine the range of DO output coil numbers for that board, in this case (341-372). The fifth coil in the range 341 to 372 would be 345, so your Modbus command should request coil 345. 06/07/02 Appendix B, Document CI-ControlWaveEXP Page 1 of 6 ControlWave I/O Expansion Rack Open Modbus Interface Information Board Status (all) DO readback status: 1-32 DI value coils 1-32 DO output coils 1-32 AI, AO outof-range status 1-16 or 1-8 AI, AO Convers-ion Error status 39 HSC Input State Status 1-12 AO Fail to State Status 9-32 Coils 9-32 (3 sets of 8) Board 1 (101-140) 140 Board 2 (141-180) 180 Board 3 (181-220) 220 Board 4 (221-260) 260 Board 5 (261-300) 300 Board 6 (301-340) 340 Board 7 (341-380) 380 Board 8 (381-420) 420 101-132 141-172 181-212 221-252 261-292 301-332 341-372 381-412 101-132 141-172 181-212 221-252 261-292 301-332 341-372 381-412 101-132 141-172 181-212 221-252 261-292 301-332 341-372 381-412 101-116 or 101-108 141-156 or 141-148 181-196 or 181-188 221-236 or 221-228 261-276 or 261-268 301-316 or 301-308 341-356 or 341-348 381-396 or 381-388 139 179 219 259 299 339 379 419 101-112 141-152 181-192 221-232 261-272 301-312 341-352 381-392 109-132 149-172 189-212 229-252 269-292 309-332 349-372 389-412 101-112 141-152 181-192 221-232 261-272 301-312 341-352 381-392 113-136 153-174 193-214 233-254 273-294 313-334 353-374 393-414 * See Note 1 HSC Reset Coils 1-12 HSC Setup Status 13-36 Coils 13-36 (2 sets of 12) Input Registers (2 byte signed registers, transmitted upper byte first) Range:101-260 (20 per board) * Note 1: First group must be set to 1 to have 2nd two groups written to board. Also, first group will always read as 0 - cleared as soon as written. 06/07/02 Appendix B, Document CI-ControlWaveEXP Page 2 of 6 ControlWave I/O Expansion Rack Open Modbus Interface Information Example: To read AI register 8 on board 2, find AI value register in the first column of the table, below, then move along that row until you reach the board 2 column to determine the range of AI value register numbers, for that board, in this case (121-136). The eighth coil in the range 121 to 136 would be 128, so your Modbus command should request register 128. AI value register 1-16 AO clamped value register 1-8 HSC lower 16 bits 1-12 Board 1 (101-120) 101-116 Board 2 (121-140) 121-136 Board 3 (141-160) 141-156 Board 4 (161-180) 161-176 Board 5 (181-200) 181-196 Board 6 (201-220) 201-216 Board 7 (221-240) 221-236 Board 8 (241-260) 241-256 101-108 121-128 141-148 161-168 181-188 201-208 221-228 241-248 101-112 121-132 141-152 161-172 181-192 201-212 221-232 241-252 Output Registers (2 byte signed registers, transmitted upper byte first) Range:501-660 (20 per board) Example: To read AO register 7 on board 5, find AO value register in the first column of the table, below, then move along that row until you reach the board 5 column to determine the range of AO value register numbers, for that board, in this case (581-588). The seventh coil in the range 581 to 588 would be 587, so your Modbus command should request register 587. AO value register 1-8 Board 1 (501-520) 501-508 Board 2 (521-540) 521-528 Board 3 (541-560) 541-548 Board 4 (561-580) 561-568 Board 5 (581-600) 581-588 Board 6 (601-620) 601-608 Board 7 (621-640) 621-628 Board 8 (641-660) 641-648 Setup Registers (2 byte signed registers, transmitted upper byte first) Range:1101-1420 (40 per board) Example: To read the third AO last hold value register on board 4, find AO last hold value registers in the first column of the table, below, then move along that row until you reach the board 4 column to determine the range of AO last hold value register numbers, for that board, in this case (1237-1244). The third register in the range 1237 to 1244 would be 1239, so your Modbus command should request register 1239. 06/07/02 Appendix B, Document CI-ControlWaveEXP Page 3 of 6 ControlWave I/O Expansion Rack Open Modbus Interface Information AI scales register 1-32 AO scales register 1-16 AO - Last Hold Value register 17-24 Board 1 (11011140) 11011132 Board 2 (11411180) 11411172 Board 3 (11811220) 11811212 Board 4 (12211260) 12211252 Board 5 (12611300) 12611292 Board 6 (13011340) 13011332 Board 7 (13411380) 13411372 Board 8 (13811420) 13811412 11011116 11411156 11811196 12211236 12611276 13011316 13411356 13811396 11171124 11571164 11971204 12371244 12771284 13171324 13571364 13971404 Long Input Registers (4 byte unsigned registers, transmitted upper word / upper byte first) Range:2101-2260 (20 per board) Example: To read the third AO last hold value register on board 4, find AO last hold value registers in the first column of the table, below, then move along that row until you reach the board 4 column to determine the range of AO last hold value register numbers, for that board, in this case (1237-1244). The third register in the range 1237 to 1244 would be 1239, so your Modbus command should request register 1239. HSC Counts Registers 1-12 HSC Timestamp Register 13 Board 1 (21012120) 21012112 Board 2 (21212140) 21212132 Board 3 (21412160) 21412152 Board 4 (21612180) 21612172 Board 5 (21812200) 21812192 Board 6 (22012220) 22012212 Board 7 (22212240) 22212232 Board 8 (22412260) 22412252 2113 2133 2153 2173 2193 2213 2233 2253 Floating Point (FP) Inputs (4 byte FP, transmitted upper word / upper byte first) Range:3101-3260 (20 per board) Example: To read the eleventh FP input on board 7, go to the Board 7 column of the table, below, to determine the range of FP inputs for that board, in this case 3221-3240. The eleventh FP input in that range would be 3231, so your Modbus command should request FP input 3231. 06/07/02 Appendix B, Document CI-ControlWaveEXP Page 4 of 6 ControlWave I/O Expansion Rack Open Modbus Interface Information FP Inputs Board 1 (31013120) 31013120 Board 2 (31213140) 31213140 Board 3 (31413160) 31413160 Board 4 (31613180) 31613180 Board 5 (31813200) 31813200 Board 6 (32013220) 32013220 Board 7 (32213240) 32213240 Board 8 (32413260) 32413260 Floating Point (FP) Outputs (4 byte FP, transmitted upper word / upper byte first) Range:4101-4260 (20 per board) Example: To read the first FP output on board 2, go to the Board 2 column of the table, below, to determine the range of FP outputs for that board, in this case 4121-4140. The first FP output in that range would be 4121, so your Modbus command should request FP output 4121. FP Outputs Board 1 (41014120) 41014120 Board 2 (41214140) 41214140 Board 3 (41414160) 41414160 Board 4 (41614180) 41614180 Board 5 (41814200) 41814200 Board 6 (42014220) 42014220 Board 7 (42214240) 42214240 Board 8 (42414260) 42414260 Floating Point (FP) Setup (4 byte FP, transmitted upper word / upper byte first) Range:5101-5420 (40 per board) Example: To read the last FP setup register on board 3, go to the Board 3 column of the table, below, to determine the range of FP setup registers for that board, in this case 41214140. The last FP setup register in that range would be 4121, so your Modbus command should request FP setup register 4121. FP Outputs Board 1 (51015140) 51015140 Board 2 (51415180) 51415180 Board 3 (51815220) 51815220 Board 4 (52215260) 52215260 Board 5 (52615300) 52615300 Board 6 (53015340) 53015340 Board 7 (53415380) 53415380 Board 8 (53815420) 53815420 Reversing the Order of Byte Transmission of a Register Swapping the order in which bytes are transmitted will cause 2 bytes to be transmitted with the low order byte first, and 4 bytes to be transmitted upper word first, low order byte first. To perform this swap, choose the proper register, from the tables above, then add 10000 to that register number when using it in a Modbus command. 06/07/02 Appendix B, Document CI-ControlWaveEXP Page 5 of 6 ControlWave I/O Expansion Rack Open Modbus Interface Information Reversing the Order of Word Transmission of a Register Swapping the order in which words are transmitted will cause 2 bytes to be transmitted as in 0 series, and will cause 4 bytes to be transmitted lower word first, high order byte first. To perform this swap, choose the proper register, from the tables above, then add 20000 to that register number when using it in a Modbus command. Reversing the Order of Byte / Word Transmission of a Register Swapping the order in which bytes/words are transmitted will cause 2 bytes to be transmitted with the low order byte first, and 4 bytes to be transmitted lower word first, low byte first. To perform this swap, choose the proper register, from the tables above, then add 30000 to that register number when using it in a Modbus command. 06/07/02 Appendix B, Document CI-ControlWaveEXP Page 6 of 6 ControlWave I/O Expansion Rack Material Safety Data Sheets Material Safety Data Sheets are provided herein to comply with OSHA’s Hazard Communication Standard, 29 CFR 1910.1200. This standard must be consulted for specific requirements. Material Safety Data Sheets are provided in the order listed in Table Z-1 below. TABLE Z-1 - MSDS for ControlWave Instruction Manual CI-ControlWaveEXP Manufacturer General Description Eagle Pitcher Lithium Thionyl Chloride Battery (1/2 AA, 3.6V, 950 mAh - On-board) SAFT America Lithium Thionyl Chloride Battery (1/2 AA, 3.6V, 950 mAh - On-board) 03/01/02 Bristol Babcock Part Number or Media Notes 395600-01-4 Eagle Pitcher P/N LTC-9C 395600-01-4 SAFT P/N LS-14250 MSDS Not provided herein. Appendix Z - CI-ControlWaveEXP MSDS BLANK PAGE Supplement Guide - S1400CW Issue: 04/05 TM SITE CONSIDERATIONS For EQUIPMENT INSTALLATION, GROUNDING & WIRING A Guide for the Protection of Site Equipment & Personnel In the Installation of ControlWave Process Automation Controllers Bristol Babcock NOTICE Copyright Notice The information in this document is subject to change without notice. Every effort has been made to supply complete and accurate information. However, Bristol Babcock assumes no responsibility for any errors that may appear in this document. Request for Additional Instructions Additional copies of instruction manuals may be ordered from the address below per attention of the Sales Order Processing Department. List the instruction book numbers or give complete model number, serial or software version number. Furnish a return address that includes the name of the person who will receive the material. Billing for extra copies will be according to current pricing schedules. ControlWave® is a re registered trademark of Bristol Babcock. Other trademarks or copyrighted products mentioned in this document are for information only, and belong to their respective companies, or trademark holders. Copyright (c) 2005 Bristol Babcock, 1100 Buckingham St., Watertown, CT 06795. No part of this manual may be reproduced in any form without the express written permission of Bristol Babcock. Supplement Guide S1400CW SITE CONSIDERATIONS FOR EQUIPMENT INSTALLATION, GROUNDING & WIRING TABLE OF CONTENTS SECTION TITLE PAGE # Section 1 - INTRODUCTION 1.1 1.2 GENERAL INTRODUCTION ....................................................................................... 1-1 MAJOR TOPICS ............................................................................................................. 1-1 Section 2 - PROTECTION 2.1 2.1.1 2.2 2.2.1 2.2.2 2.3 PROTECTING INSTRUMENT SYSTEMS................................................................... 2-1 Quality Is Conformance To Requirements.................................................................... 2-1 PROTECTING EQUIPMENT & PERSONNEL ........................................................... 2-1 Considerations For The Protection of Personnel .......................................................... 2-2 Considerations For The Protection of Equipment ........................................................ 2-2 OTHER SITE SAFETY CONSIDERATIONS............................................................... 2-3 Section 3 - GROUNDING & ISOLATION 3.1 3.2 3.3 3.3.1 3.3.1.1 3.3.1.2 3.3.1.3 3.3.2 3.3.3 3.4 3.4.1 3.4.2 POWER & GROUND SYSTEMS................................................................................... 3-1 IMPORTANCE OF GOOD GROUNDS......................................................................... 3-1 EARTH GROUND CONNECTIONS............................................................................. 3-1 Establishing a Good Earth Ground. .............................................................................. 3-1 Soil Conditions ................................................................................................................ 3-2 Soil Types ........................................................................................................................ 3-2 Dry, Sandy or Rocky Soil................................................................................................ 3-4 Ground Wire Considerations. ........................................................................................ 3-5 Other Grounding Considerations. ................................................................................. 3-6 ISOLATING EQUIPMENT FROM THE PIPELINE ................................................... 3-7 Meter Runs Without Cathodic Protection..................................................................... 3-7 Meter Runs With Cathodic Protection .......................................................................... 3-7 Section 4 - LIGHTNING ARRESTERS & SURGE PROTECTORS 4.1 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.2 STROKES & STRIKES .................................................................................................. 4-1 Chance of Being Struck by Lightning. .......................................................................... 4-1 Antenna Caution ............................................................................................................ 4-3 Ground Propagation ....................................................................................................... 4-5 Tying it all Together....................................................................................................... 4-5 Impulse Protection Summary ........................................................................................ 4-5 USE OF LIGHTNING ARRESTERS & SURGE PROTECTORS................................ 4-6 Section 5 - WIRING TECHNIQUES 5.1 5.2 5.2.1 OVERVIEW ....................................................................................................................5-1 INSTRUMENT WIRING. .............................................................................................. 5-1 Common Returns ............................................................................................................5-1 Supplement S1400CW Page 0-1 Table Of Contents Supplement Guide S1400CW SITE CONSIDERATIONS FOR EQUIPMENT INSTALLATION, GROUNDING & WIRING TABLE OF CONTENTS SECTION TITLE PAGE # Section 5 - WIRING TECHNIQUES (Continued) 5.2.2 5.2.3 5.2.4 5.2.5 5.2.6 5.2.7 5.2.8 5.2.9 5.2.10 Use of Twisted Shielded Pair Wiring (with Overall Insulation).................................. 5-2 Grounding of Cable Shields. .......................................................................................... 5-3 Use of Known Good Earth Grounds .............................................................................. 5-3 Earth Ground Wires ....................................................................................................... 5-3 Working Neatly & Professionally .................................................................................. 5-3 High Power Conductors and Signal Wiring .................................................................. 5-4 Use of Proper Wire Size ................................................................................................. 5-4 Lightning Arresters & Surge Protectors ....................................................................... 5-4 Secure Wiring Connections ............................................................................................ 5-5 REFERENCE DOCUMENTS 1. 2. 3. 4. 5. 6. 7. IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems - ANSI/IEEE Std 142-1982 IEEE Guide for the Installation of Electrical Equipment to Minimize Electrical Noise inputs to Controllers from External Sources - IEE Std 518-1982 Lightning Strike Protect; Roy B. Carpenter, Jr. & Mark N. Drabkin, Ph.D.; Lightning Eliminators & Consultant, Inc., 6687 Arapahoe Road, Boulder Colorado Lightning Protection Manual for Rural Electric Systems, NRECA Research Project 82-5, Washington DC, 1983 Grounding for the Control of EMI; Hugh W. Denny; Don White Consultants, Inc., 1983, 1st Edition Fundamentals of EGM - Electrical Installations; Michael D. Price; NorAm Gas Transmission, 525 Milam Street, Shreveport, Louisiana 71151 TeleFlow Modem Grounding Kit 621495-01-8 Installation Instructions - PIP-3530MGKI; Bristol Babcock, Watertown, CT 06795 Supplement S1400CW Page 0-2 Table Of Contents Section 1 - Overview 1.1 INTRODUCTION This document provides information pertaining to the installation of ControlWave systems; more specifically, information covering reasons, theory and techniques for protecting your personnel and equipment from electrical damage. Your instrument system affects the quality of service provided by your company and many aspects of its operational safety. Loss of instruments means lost production and profits as well as increased expenses. Information contained in this document is for educational purposes. Bristol Babcock makes no warranties or guarantees on the effectiveness or the safety of techniques described herein. Where the safety of installations and personnel is concerned, refer to the National Electrical Code Rules and rules of local regulatory agencies. 1.2 MAJOR TOPICS Topics are covered in seven sections designed to pinpoint major areas of concern for the protection of site equipment and personnel. The following overview is provided for each of the major sections. · Section 2 - Protection This section provides the reasons for protecting instrument systems. An overview of the definition of quality and what we are trying to accomplish in the protection of site installations and how to satisfy the defined requirements is presented. Additionally, this section provides considerations for the protection of personnel and equipment. · Section 3 - Grounding & Isolation Information pertaining to what constitutes a good earth ground, how to test and establish such grounds, as well as when and how to connect equipment to earth grounds is provided · Section 4 - Lightning Arresters & Surge Protectors Some interesting information dealing with Lightning strikes and strokes is presented in technical and statistical form along with a discussion of how to determine the likelihood of a lightning strike. Protecting equipment and personnel during the installation of radios and antenna is discussed in a review of the dangers to equipment and personnel when working with antennas. Reasons for the use of lightning arresters and surge protectors are presented along with overviews of how each device protects site equipment. · Section 5 - Wiring Techniques Installation of Power and “Measurement & Control” wiring is discussed. Information on obscure problems, circulating ground and power loops, bad relays, etc. is presented. Good wire preparation and connection techniques along with problems to avoid are discussed. This sections list the ten rules of instrument wiring. Section 1 - Overview Page 1-1 S1400CW Section 2 - Protection 2.1 PROTECTING INSTRUMENT SYSTEMS Electrical instrumentation is susceptible to damage from a variety of natural and man made phenomena. In addition to wind, rain and fire, the most common types of system and equipment damaging phenomena are lightning, power faults, communication surges & noise and other electrical interference’s caused by devices such as radios, welders, switching gear, automobiles, etc. Additionally there are problems induced by geophysical electrical potential & noise plus things that are often beyond our wildest imagination. 2.1.1 Quality Is Conformance To Requirements A quality instrumentation system is one that works reliably, safely and as purported by the equipment manufacturer (and in some cases by the system integrator) as a result of good equipment design and well defined and followed installation practices. If we except the general definition of quality to be, “quality is conformance to requirements,” we must also except the premise that a condition of “quality” can’t exist where requirements for such an end have not been evolved. In other words, you can’t have quality unless you have requirements that have been followed. By understanding the requirements for a safe, sound and reliable instrumentation system, and by following good installation practices (as associated with the personnel and equipment in question), the operational integrity of the equipment and system will be enhanced. Understanding what is required to properly install BBI equipment in various environments, safely, and in accordance with good grounding, isolating and equipment protection practices goes a long way toward maintaining a system which is healthy to the owner and customer alike. Properly installed equipment is easier to maintain and operate, and is more efficient and as such more profitable to our customers. Following good installation practices will minimize injury, equipment failure and the customer frustrations that accompany failing and poorly operating equipment (of even the finest design). Additionally, personnel involved in the installation of a piece of equipment add to or subtract from the reliability of a system by a degree which is commensurate with their technical prowess, i.e., their understanding of the equipment, site conditions and the requirements for a quality installation. 2.2 PROTECTING EQUIPMENT & PERSONNEL ControlWave installations must be performed in accordance with National Electrical Code Rules, electrical rules set by local regulatory agencies, and depending on the customer environment (gas, water, etc), other national, state and local agencies such as the American Water Works Association (AWWA). Additionally, installation at various customer sites may be performed in conjunction with a “safety manager” or utility personnel with HAZMAT (hazardous material) training on materials present (or potentially present) as required by OSHA, the customer, etc. Section 2 - Protection Page 2-1 S1400CW 2.2.1 Considerations For The Protection of Personnel Always evaluate the site environment as if your life depended on it. Make sure that you understand the physical nature of the location where you will be working. Table 2-1 provides a general guideline for evaluating an installation site. Table 2-1 - Installation Site Safety Evaluation Guide # 1 2 3 4 5 6 7 8 9 Guide Indoor or outdoor – Dress Appropriately If outdoor, what kind of environment, terrain, etc. Watch out for local varmint (bees, spiders, snakes, etc.) If indoor or outdoor – determine if there are any pieces of dangerous equipment or any processes which might be a risk to your safety If in a tunnel, bunker, etc. watch out for a build up of toxic or flammable gases. Make sure the air is good. Watch out for local varmint (bees, spiders, snakes, etc.) Hazardous or Non-Hazardous Environment – Wear appropriate safety equipment and perform all necessary safety measures. Before installing any equipment or power or ground wiring, make sure that there are no lethal (life threatening) voltages between the site where the instrument will be installed and other equipment, pipes, cabinets, etc. or to earth itself. Never assume that adjacent or peripheral equipment has been properly installed and grounded. Determine if this equipment and the ControlWave unit in question can be touched simultaneously without hazard to personnel and/or equipment? Before embarking to remote locations where there are few or no human inhabitants ask a few simple questions like, should I bring water, food, hygienic materials, first aid kit, etc? Be Prepared! Observe the work habits of those around you – for your own safety! Some of the items that a service person should consider before ever going on site can be ascertained by simply asking questions of the appropriate individual. Obviously other safety considerations can only be established at the installation site. 2.2.2 Considerations For The Protection of Equipment Always evaluate the site installation/service environment and equipment. Understand the various physical interfaces you will be dealing with such as equipment mounting and supporting, ControlWave analog and digital circuits, power circuits, communication circuits and various electrical grounds. Table 2-2 provides a general guideline for evaluating the equipment protection requirements of an installation site. Table 2-2 - Equipment Protection Site Safety Evaluation Guide # 1 2 3 4 5 Guide Environment - Class I, Division 2 - Nonincendive Environment - Class I, Division 1 - Intrinsically Safe Other - Safe or unrated area Earth Ground - Established by mechanical/electrical or (both) or not at all. Is the area prone to lightning strikes? Are there surge suppressors installed or to be installed? Are there overhead or underground power or communication cables in the immediate area? S1400CW Page 2-2 Reference Section See Appendix A of CI Manual See Appendix B of CI Manual See Section 3 See Section 4 See Section 4 See Section 2.3 Section 2 - Protection Table 2-2 - Equipment Protection Site Safety Evaluation Guide (Continued) # 6 7 8 9 2.3 Guide Is there an antenna in the immediate area? How close is other equipment? Can someone safely touch this equipment and a ControlWave simultaneously? Determine equipment ground requirements. How will the ControlWave and its related wiring be grounded? Consider Earth Ground, Circuit Ground, Conduit Ground, Site Grounds! Are there any obviously faulty or questionable power or ground circuits? Reference Section See Section 4.1.2 See Section 2.3 See Section 3 See Section 2.3 OTHER SITE SAFETY CONSIDERATIONS Overhead or underground power or communication cables must be identified prior to installing a new unit. Accidentally cutting, shorting or simply just contacting power, ground, communication or process control I/O wiring can have potentially devastating effects on site equipment, the process system and or personnel. Don’t assume that it is safe to touch adjacent equipment, machinery, pipes, cabinets or even the earth itself. Adjacent equipment may not have been properly wired or grounded, may be defective or may have one or more loose system grounds. Measure between the case of a questionable piece of equipment and its earth ground for voltage. If a voltage is present, something is wrong. AC powered equipment with a conductive case should have the case grounded. If you don’t see a chassis ground wire, don’t assume that it is safe to touch this equipment. If you notice that equipment has been grounded to pipes, conduit, structural steel, etc., you should be leery. Note: AWWA’s policy on grounding of electric circuits on water pipes states, “The American Water Works Association (AWWA) opposes the grounding of electrical systems to pipe systems conveying water to the customer’s premises….” Be sure that the voltage between any two points in the instrument system is less than the stand-off voltage. Exceeding the stand-off voltage will cause damage to the instrument and will cause the instrument to fail. Section 2 - Protection Page 2-3 S1400CW Section 3 - Grounding & Isolation 3.1 POWER & GROUND SYSTEMS ControlWaves utilize DC power systems. AC power supplies are not provided with ControlWave units. ControlWave, ControlWave MICRO, ControlWave EFM/GFC/EFC, ControlWaveRED, ControlWaveREDIO and ControlWave I/O Expansion Racks are provided with a Ground Lug that accommodates up to a #4 AWG size wire for establishing a connection to Earth Ground. In the case of the ControlWaveLP, a Chassis Ground termination terminal (TB2, Pin-3), that accepts up to a #14 AWG size wire, is provided on the unit’s Power Supply/Sequencer Board. 3.2 IMPORTANCE OF GOOD GROUNDS ControlWave units (see above) are utilized in instrument and control systems that must operate continually and within their stated accuracy over long periods of time with minimum attention. Failures resulting from an improperly grounded system can become costly in terms of lost time and disrupted processes. A properly grounded system will help prevent electrical shock hazards resulting from contact with live metal surfaces, provide additional protection of equipment from lightning strikes and power surges, minimize the effects of electrical noise and power transients, and reduce signal errors caused by ground wiring loops. Conversely, an improperly grounded system may exhibit a host of problems that appear to have no relation-ship to grounding. It is essential that the reader (service technician) have a good under-standing of this subject to prevent needless troubleshooting procedures. WARNING This device must be installed in accordance with the National Electrical Code (NEC) ANSI/NEPA-70. Installation in hazardous locations must also comply with Article 500 of the code. For information on the usage of ControlWave units in Class I, Division 2, Groups C & D Hazardous and Nonhazardous locations, see appendix A of the applicable Customer Instruction (CI) manual. For information on the usage of ControlWave units in Class I, Division 1, Groups C & D Hazardous locations, see appendix B of the applicable Customer Instruction (CI) manual. 3.3 EARTH GROUND CONNECTIONS To properly ground a ControlWave unit, the units Chassis Ground (post or terminal) must ultimately be connected to a known good Earth Ground. Observe recommendations provided in topics Establishing a Good Earth Ground and Ground Wire Considerations. 3.3.1 Establishing a Good Earth Ground A common misconception of a ground is that it consists of nothing more than a metal pipe driven into the soil. While such a ground may function for some applications, it will often Section 3 - Grounding & Isolation Page 3-1 S1400CW not be suitable for a complex system of sophisticated electronic equipment. Conditions such as soil type, composition and moisture will all have a bearing on ground reliability. A basic ground consists of a 3/4-inch diameter rod with a minimum 8-foot length driven into conductive earth to a depth of about 7-feet as shown in Figure 3-1. Number 3 or 4 AWG solid copper wire should be used for the ground wire. The end of the wire should be clean, free of any coating and fastened to the rod with a clamp. This ground connection should be covered or coated to protect it from the weather and the environment. Figure 3-1 - Basic Ground Rod Installation 3.3.1.1 Soil Conditions Before installing a ground rod, the soil type and moisture content should be analyzed. Ideally, the soil should be moist and moderately packed throughout to the depth of the ground rod. However, some soils will exhibit less than ideal conditions and will require extra attention. Soil types can be placed into two general categories with respect to establishing and maintaining a good earth ground, i.e., ‘Good Soil’ and ‘Poor Soil.’ To be a good conductor, soil must contain some moisture and free ions (from salts in the soil). In very rainy areas, the salts may be washed out of the soil. In very sandy or arid area the soil may be to dry and/or salt free to a good conductor. If salt is lacking add rock salt (NaCl); if the soil is dry add calcium chloride (CaCl2). 3.3.1.2 Soil Types: Good Damp Loam Salty Soil or Sand Farm Land Poor Back Fill Dry Soil Sand Washed by a Lot of Rain Dry Sand (Desert) Rocky Soil Ground Beds must always be tested for conductivity prior to being placed into service. A brief description of ground bed testing in ‘Good Soil’ and ‘Poor Soil’ is provided herein. Details on this test are described in the National Electrical Code Handbook. Once a reliable S1400CW Page 3-2 Section 3 - Grounding & Isolation ground has been established, it should be tested on a regular basis to preserve system integrity. Figure 3-2 - Basic Ground Bed Soil Test Setup Figure 3-3 - Basic Ground Bed Soil Test Setup with Additional Ground Rods Figure 3-2 shows the test setup for ‘Good Soil’ conditions. If the Megger* reads less than 5 ohms, the ground is good. The lower the resistance, the better the earth ground. If the Section 3 - Grounding & Isolation Page 3-3 S1400CW Megger reads more than 10 ohms, the ground is considered ‘poor.’ If a poor ground is indicated, one or more additional ground rods connected 10 feet from the main ground rod should be driven into the soil and interconnected via bare AWG 0000 copper wire and 1” x ¼-20 cable clamps as illustrated in Figure 3-3). * Note: Megger is a Trademark of the Biddle Instrument Co. (now owned by AVO International). Other devices that may be used to test ground resistance are “Viboground”; Associated Research, Inc., “Groundmeter”; Industrial Instruments, Inc., and “Ground-ohmer”; Herman H. Sticht Co., Inc. If the Megger still reads more than 10 ohms, mix a generous amount of cooking salt, ice cream salt or rock salt with water and then pour about 2.5 to 5 gallons of this solution around each rod (including the test rods). Wait 15 minutes and re-test the soil. If the test fails, the soil is poor and a ‘Poor Soil Ground Bed’ will have to be constructed. Figure 3-4 shows a typical Poor Soil Ground Bed Electrode. A Poor Soil Ground Bed will typically consists of four or more 10-foot long electrodes stacked vertically and separated by earth. Figure 3-5 shows the construction of a Poor Soil Ground Bed. For some poor soil sites, the ground bed will be constructed of many layers of ‘Capacitive Couplings’ as illustrated. In extremely poor soil sites one or more 3’ by 3’ copper plates (12 gauge or 1/16” thick) will have to be buried in place of the electrodes. Figure 3-4 - Ground Electrode Construction for Poor Soil Conditions 3.3.1.3 Dry, Sandy or Rocky Soil Very dry soil will not provide enough free ions for good conductance and a single ground rod will not be effective. A buried counterpoise or copper screen is recommended for these situations. It will be necessary to keep the soil moist through regular applications of water. Sandy soil, either wet or dry, may have had its soluble salts leached out by rain water, thereby reducing conductivity of the ground. High currents from lightning strikes could also melt sand and cause glass to form around the ground rod, rendering it ineffective. A buried counterpoise or copper screen is preferred for these installations along with regular applications of salt water. Rocky soil can pose many grounding problems. A counterpoise or copper plate will probably be required. Constructing a trench at the grounding site and mixing the fill with a hygroscopic salt such as calcium chloride may help for a time. Soaking the trench with water on a regular basis will maintain conductivity. Units with phone modems require the use of a lightning arrester. The lightning arrester must be situated at the point where the communication line enters the building. S1400CW Page 3-4 Section 3 - Grounding & Isolation Figure 3-5 - Poor Soil Ground Bed Construction Diagram 3.3.2 Ground Wire Considerations ControlWave, ControlWave MICRO, ControlWave EFM/GFC/XFC, ControlWaveRED, ControlWave REDIO & ControlWave I/O Expansion Rack ControlWave Chassis are provided with a Ground Lug that accommodates up to a #4 AWG wire size. A ground wire must be run between the Chassis Ground Lug and a known good Earth Ground. The cases of the various ControlWave Modules are connected to Chassis Ground when they have been installed and secured via their two Captured Panel Fasteners. As an extra added precaution, it is recommended that a #14 AWG wire be run from PSSM Power Connector TB2-5 (Chassis Ground) (PSSM Connector TB1-3 for ControlWave MICRO unit) (SCM Connector TB1-3 for ControlWave EFM) to the same known good Earth Ground. ControlWaveLP Process Automation Controller A #14 AWG ground wire must be run from the ControlWaveLP’s PSSB Terminal TB2-3 (Chassis Ground) to a known good Earth Ground. In lieu of a direct connection to Earth Section 3 - Grounding & Isolation Page 3-5 S1400CW Ground, it is recommended that the unit’s Chassis Ground Terminal be connected to a conductive mounting panel or plate, a user supplied Ground Lug or a user supplied Ground Bus. The panel, lug or bus in turn must be connected to a known good Earth Ground via a #4 AWG wire. General Considerations The following considerations are provided for the installation of ControlWave system grounds: i Size of ground wire (running to Earth Ground should be #4 AWG. It is recommended that stranded copper wire is used for this application and that the length should be as short as possible. i This ground wire should be clamped or brazed to the Ground Bed Conductor (that is typically a stranded copper AWG 0000 cable installed vertically or horizontally). i The wire ends should be tinned with solder prior to installation. i The ground wire should be run such that any routing bend in the cable has a minimum radius of 12-inches below ground and 8-inches above ground. The units Earth Ground Cable should be clamped to an exposed Ground Rod or to an AWG 0000 stranded copper Ground Cable that in turn should be connected to either an Earth Ground Rod or Earth Ground Bed. Both ends of the units Earth Ground Cable must be free of any coating such as paint or insulated covering as well as any oxidation. The connecting point of the Ground Rod or AWG 0000 Ground Cable must also be free of any coating and free of oxidation. Once the ground connection has been established (at either the Ground Rod or Ground Cable) it should be covered or coated to protect it from the environment. 3.3.3 Other Grounding Considerations Figure 3-6 - Grounding of Phone Line S1400CW Page 3-6 Section 3 - Grounding & Isolation For applications employing equipment that communicates over telephone lines, a lightning arrester Must Be provided. For indoor equipment the lightning arrester must be installed at the point where the communication line enters the building as shown in Figure 3-6. The ground terminal of this arrester must connect to a ground rod and/or a buried ground bed. Gas lines also require special grounding considerations. If a gas meter run includes a thermocouple or RTD sensor installed in a thermowell, the well (not the sensor) must be connected to a gas discharge-type lightning arrester as shown in Figure 3-7. A copper braid, brazed to the thermal well, is dressed into a smooth curve and connected to the arrester as shown. The curve is necessary to minimize arcing caused by lightning strikes or high static surges. The path from the lightning arrester to the ground bed should also be smooth and free from sharp bends for the same reason. Figure 3-7 - Grounding of Thermometer Well in Gas Line 3.4 ISOLATING EQUIPMENT FROM THE PIPELINE 3.4.1 Meter Runs Without Cathodic Protection ControlWave EFM/GFC/XFC’s may be mounted directly on the pipeline or remotely on a vertical stand-alone two-inch pipe (see Figure 3-8). The Earth Ground Cable is to run between the ControlWave EFM/GFC/XFC’s Ground Lug and Earth Ground (Rod or Bed) even though the ControlWave EFM/GFC/XFC’s Multivariable Transducer may be Section 3 - Grounding & Isolation Page 3-7 S1400CW grounded to the pipeline. If any pressure transmitters or pulse transducers are remotely mounted, connect their chassis grounds to the pipeline or earth ground. Figure 3-8 - ControlWave EFM (Installation is similar to GFC/XFC) Remote Installation without Cathodic Protection 3.4.2 Meter Runs With Cathodic Protection Dielectric isolators are available from Bristol Babcock and are always recommended as an added measure in isolating the ControlWave EFM/GFC/XFC from the pipeline even though the ControlWave EFM/GFC/XFC does provide 500V galvanic isolation from the pipeline and should not be affected by cathodic protection or other EMF on the pipeline. ControlWave EFM/GFC/XFC may be mounted directly on the pipeline (see Figure 3-9) or remotely on a vertical stand-alone two-inch stand-pipe (see Figure 3-10). It is recommended that isolation fitting always be used in remotely mounted meter systems. An isolation fittings or gasket should be installed between the following connections: S1400CW Page 3-8 Section 3 - Grounding & Isolation • • • all conductive tubing that runs between the pipeline and mounting valve manifold and/or the units multivariable pressure transducer all conductive connections or tubing runs between the ControlWave EFM/GFC and turbine meter, pulse transducer, or any input other device that is mounted on the pipeline any Temperature Transducer, Pressure Transmitter, etc. and their mount/interface to the pipeline Figure 3-9 - ControlWave EFM (Installation is similar to EFM/GFC/XFC) Direct Mount Installation (with Cathodic Protection) The ground conductor connects between the ControlWave EFM/GFC/XFC’s Ground Lug and a known good earth ground. Connect the cases of Temperature Transducers, Pressure Transmitters, etc., to the known good earth ground. If the mounting 2-inch pipe is in continuity with the pipeline it will have to be electrically isolated from the ControlWave EFM/GFC/XFC. Use a strong heat-shrink material such as RAYCHEM WCSM 68/22 EU 3140. This black tubing will easily slip over the 2-inch pipe and then after uniform heating (e.g., with a rose-bud torch) it electrically insulates and increases the strength of the pipe stand. Section 3 - Grounding & Isolation Page 3-9 S1400CW See BBI Specification Summary F1670SS-0a for information on PGI Direct Mount Systems and Manifolds. Figure 3-10 – ControlWave EFM (Installation is similar to GFC/XFC) Remote Installation (with Cathodic Protection) S1400CW Page 3-10 Section 3 - Grounding & Isolation Section 4 - Lightning Arresters & Surge Protectors 4.1 STROKES & STRIKES Lightning takes the form of a pulse that typically has a 2 µS rise and a 10 µS to 40 µS decay to a 50% level. The IEEE standard is an 8 µS by 20 µS waveform. The peak current will average 18 KA for the first impulse and about half of that for the second and third impulses. Three strokes (impulses) is the average per lightning strike. The number of visible flashes that may be seen is not necessarily the number of electrical strokes. A lightning strike acts like a constant current source. Once ionization occurs, the air becomes a luminous conductive plasma reaching up to 60,000° F. The resistance of a struck object is of little consequence except for the power dissipation on the object (I2 x R). Fifty percent of all lightning strikes will have a first impulse of at least 18 KA, ten percent will exceed the 60 KA level, and only about one percent will exceed 120 KA. 4.1.1 Chance of Being Struck by Lightning The map of Figure 4-1 shows the average annual number of thunderstorm days (Isokeraunic level) for the various regions within the continental U.S.A. This map is not representative of the severity of the storm or the number of lightning strikes since it does not take into account more than one lightning strike in a thunderstorm day. The Isokeraunic or Isoceraunic number provides a meteorological indication of the frequency of thunderstorm activity; the higher the Isokeraunic number the greater the lightning strike activity for a given area. These levels vary across the world from a low of 1 to a high of 300. Within the United States the Isokeraunic level varies from a low of 1 to a high of 100. Figure 4-1 - Average Thunderstorm Days of the Year (for Continental USA) Section 4 - Lightning & Surge Page 4-1 S1400CW Thunderstorms are cloud formations that produce lightning strikes (or strokes). Across the United States there is an average of 30 thunderstorm days per year. Any given storm may produce from one to several strokes. Data on the subject indicates that for an average area within the United States there can be eight to eleven strokes to each square mile per year. The risk of stroke activity is increased for various areas such central Florida where up to 38 strokes to each square mile per year are likely to occur. To determine the probability of a given structure (tower, building, etc.) (within your location) being struck, perform the following computation: 1. Using the map of Figure 4-1 (or a comparable meteorological map for your local), find the Isokeraunic level (I) for your area. Then using Chart 1, find “A” for your area. 2. Refer to Figure 4-1 to find the latitude. Then using Chart 2, find “B” for your latitude (Lat.°). 3. Multiply “A” x “B” to get “C”. 4. To calculate the number of lightning strikes per year that are likely to strike a given object (tower, mast, etc.), use the equation that follows (where “C” was calculated in step 3 and “H” is equal to the height of the object. Strikes Per Year = (“C” x H2) ÷ (.57 x 106 ) Chart 1 I 5 10 20 30 40 50 60 70 80 90 100 “A” 8 26 85 169 275 402 548 712 893 1069 1306 Chart 2 LAT.° 25 30 35 40 45 “B” .170 .200 .236 .280 .325 Note for these charts: I = Thunderstorm Days Per Year (Isokeraunic Number) A = Stroke activity for associated Isokeraunic Area B = Height/Stroke coefficient for associated latitude For Example: On Long Island, New York (Isokeraunic number 20), Chart 1 gives “A” to equal 85. The latitude is approximately 40°. Referring to Chart 2, “B” is found to be equal to .28. “C” for this example is equal to 23.80. Using the equation for strikes per year, it is determined that a 100-foot tower has .4 chances per year of being struck by lightning. Assuming that no other structures are nearby, the tower will more than likely be struck by lightning at least once in three years. Note: The Isokeraunic activity numbers connoted as I, “A” and “B” in Charts 1 and 2 above are provided for the continental United States. Isokeraunic data for various countries is available from various federal or state Civil Engineering or Meterorelogical organizations. This information is typically available from manufacturers of lightning strike protection equipment (such as Lightning Arresters). Since ControlWave, ControlWave MICRO, ControlWave EFM/GFC/XFC, ControlWaveLP and ControlWaveEXP units are dc operated systems that are isolated from AC grids, they are typically immune to lightning strikes to power lines or power equipment (except for inductive flashover due to close installation proximity). However, once a radio or S1400CW Page 4-2 Section 4 - Lightning & Surge modem has been interfaced to a ControlWave, ControlWave MICRO, ControlWave EFM/GFC/XFC, ControlWaveLP, or ControlWaveEXP the possibility of damage due to a lightning strike on power or telephone lines or to a radio antenna or the antenna’s tower must be considered. It is recommended that the additional lightning protection considerations listed below be followed for units installed in areas with a high possibility or history of stroke activity. Units interfaced to a modem: In series with the phone line (as far away as possible from the equipment) - for indoor installations the lightning arrester should typically be located at the point where the line enters the structure. Units interfaced to a radio: Mount antenna discharge unit (lightning arrester) as close as possible to where the lead in wire enters the structure. See Antenna Caution below. 4.1.2 Antenna Caution Each year hundreds of people are killed, mutilated, or receive severe permanent injuries when attempting to install or remove an antenna or antenna lead. In many cases, the victim was aware of the danger of electrocution but failed to take adequate steps to avoid the hazard. For your safety, and for proper installation maintenance, please read and follow the safety precautions that follow - they may save your life. i When installing or servicing an antenna: DO NOT use a metal ladder. DO NOT step onto or touch an antenna mast while power is applied to an associated radio unless the radio is a low power (low current) type. DO NOT work on a wet or windy day, especially during a thunderstorm or when there is lightning or thunder in your area. Dress properly; shoes with rubber soles and heels, rubber gloves, long sleeve shirt or jacket. i The safe distance from power lines should be at least twice the height of the antenna and mast combination. i Antenna Grounding per National Electrical Code Instructions: A. Use AWG 10 or 8 aluminum or AWG 1 copper-clad steel or bronze wire, or larger as ground wires for both the mast and lead-in. Securely clamp the wire to the bottom of the mast. B. Secure lead-in wire from antenna to antenna discharge (lightning arrester) unit and the mast ground wire to the structure (building, shed, etc.) with stand-off insulators spaced from 4 feet (1.22 meters) to 6 feet (1.83 meters) apart. C. Mount antenna discharge unit as close as possible to where the lead-in wire enters the structure. D. The hole drilled through the wall for the lead-in wire should be just large enough to accommodate the cable. Before drilling this hole, make sure there are no wires or pipes, etc. in the wall. E. Push the cable through the hole and form a rain drip loop close to where the wire enters the exterior of the structure. F. Caulk around the lead-in wire (where it enters the structure) to keep out drafts. G. Install lightning arresters (antenna discharge units). The grounding conductor should be run in as straight a line as practicable from the antenna mast and/or the antenna discharge units to grounding electrode(s). H. Only connect the antenna cable to the radio after the mast has been properly grounded and the lead-in cable has been properly connected to lightning arresters which in turn have each been properly connected to a known good earth ground. Section 4 - Lightning & Surge Page 4-3 S1400CW Figure 4-2 - Radio Antenna Field Installation Site Grounding Diagram For all systems it is best to have all communication equipment input/output grounds tied together. In the case of ControlWave units, this is accomplished via the unit’s Chassis Ground (Typically at a ground lug, ground bus or ground plate). However additional S1400CW Page 4-4 Section 4 - Lightning & Surge communication equipment lightning arresters and surge suppressors should be tied to the same system ground. System ground consists of the tower leg grounds utility ground and bulkhead-equipment ground-stakes that are tied together via bare copper wire. 4.1.3 Ground Propagation As in any medium, a dynamic pulse, like R.F., will take time to propagate. This propagation time will cause a differential step voltage to exist in time between any two ground rods that are of different radial distances from the strike. With a ground rod tied to a struck tower, the impulse will propagate its step voltage outwardly from this rod in ever-expanding circles, like a pebble thrown into a pond. If the equipment house has a separate ground rod and the power company and/or telephone company grounds are also separate, the dynamic step voltage will cause currents to flow to equalize these separate ground voltages. Then if the coax cable (associated with a radio) is the only path linking the equipment chassis with the tower ground, the surge can destroy circuitry. 4.1.4 Tying it all Together To prevent this disaster from occurring, a grounding system must be formed which interconnects all grounds together. This will equalize and distribute the surge charge to all grounds, and at the same time, it will make for a lower surge impedance ground system. This interconnection can be done as a grid, where each ground has a separate line to each other ground, or by using a “rat Race” ring which forms a closed loop (not necessarily a perfect circle) which surrounds the equipment house completely. By making this interconnection, it will be necessary to use proper I/O protectors for the equipment. Of course, these should be a requirement regardless of whether this grounding technique is used. I/O protectors are used for power lines (even those these don’t feed into a ControlWave unit), telephone lines, and also to minimize EMI pick-up from a strike. Ideally it is best to place all I/O protectors on a common panel that has a low inductance path to the ground system. The ControlWave units would then have a single ground point from its Chassis Ground Terminal/Ground Lug to this panel. In lieu of this, the ControlWave unit in question should be tied to a ground rod that in turn is connected to the Earth/System Ground created for the site. Your protected equipment connected to a common single ground system, will now be just like a bird sitting on a high tension wire. When lightning strikes, even with a 50 ohm surge impedance ground system, the entire system consisting of equipment, ground system, building, etc., will all rise together to the one million volt peak level (for example) and will all decay back down together. So long as there is no voltage differential (taken care of by protectors and ground interconnections, there will be no current flow through the equipment and therefore no resulting equipment damage. 4.1.5 Impulse Protection Summary i i i i Use more than one ground rod. Place multi-ground stakes more than their length apart. Tie Power, Telco, Tower, Bulkhead and equipment ground together. Make all ground interconnect runs that are above ground with minimum radius bends of eight inches and run them away from other conductors and use large solid wire or a solid strap. Section 4 - Lightning & Surge Page 4-5 S1400CW i Watch out for dissimilar metals connections and coat accordingly. i Use bare wire radials together where possible with ground stakes to reduce ground system impedance. i Use I/O protectors (Phone line, Radio) with a low inductance path to the ground system. i Ground the Coaxial Cable Shield (or use an impulse suppressor) at the bottom of the tower just above the tower leg ground connection. 4.2 USE OF LIGHTNING ARRESTERS & SURGE PROTECTORS Units equipped with radios or modems use lightning arresters and surge protectors to protect equipment from lightning strikes, power surges and from damaging currents that have been induced onto communication lines. The first line of defense is the Lightning Arrester. These devices typically use gas discharge bulbs that can shunt high currents and voltages to earth ground when they fire. The high current, high voltage gas discharge bulb has a relatively slow response time and only fire when their gas has been ionized by high voltage. The second line of defense is the Surge Protector, which is made of solid state devices, fires very quickly and conducts low voltages and currents to ground. Surge protectors are built into BBI 9600 bps modems. Lightning Arresters are applied to circuits as follows: i Equipment or circuits that can be exposed to lightning strikes, falling power lines, high ground currents caused by power system faults, by operational problems on electric railways, etc. i Equipment installed in dry, windy areas, such as the Great Plains and the Southwest Desert in the United States. Wind and wind blown dust can cause high voltages (static) to appear on overhead wires, fences, and metal buildings. Note: Lightning Arresters may explode if lightning strike is very close. Mount lightning arresters where flying parts won't cause injury to equipment or personnel. S1400CW Page 4-6 Section 4 - Lightning & Surge Section 5 - Wiring Techniques 5.1 OVERVIEW This section provides information pertaining to good wiring practices. Installation of Power and “Measurement & Control” wiring is discussed. Information on obscure problems, circulating ground and power loops, bad relays, etc. is presented. Good wire preparation and connection techniques along with problems to avoid are discussed. 5.2 INSTRUMENT WIRING Each of the rules listed below is briefly discussed; the emphasis herein is placed on the avoidance of problems as well as equipment safety. Rule 1 - Never utilize common returns. Rule 2 - Use twisted shielded pairs (with overall insulation) on all Signal/Control circuits. Rule 3 - Ground cable shields at one end only. Rule 4 - Use known good earth grounds (Rod, Bed, System) and test them periodically, Rule 5 - Earth connections must utilize smoothly dressed large wire. Rule 6 - Perform all work neatly and professionally. Rule 7 - Route high power conductors away from signal wiring according to NEC Rules. Rule 8 - Use appropriately sized wires as required by the load. Rule 9 - Use lightning arresters and surge protectors. Rule 10 - Make sure all wiring connections are secure. 5.2.1 Common Returns Use of common returns on I/O wiring is one of the most common causes of obscure and difficult to troubleshoot control signal problems. Since all wires and connections have distributed resistance, inductance and capacitance, the chances of a achieving a balanced system when common returns are present is very remote. Balanced systems (or circuits) are only achieved when all currents and voltages developed in association with each of the common returns are equal. In a balanced system (or circuit) there are no noise or measurment errors introduced due to by “sneak circuits.” The illustration of Figure 5-1 shows the difference between testing an I/O circuit that is discrete and has no sneak circuits and one that utilizes common returns. Common sense tells us that it is tough to mix up connections to a twisted shielded pair (with overall vinyl covering) to every end device. Do yourself a favor; to make start up easier, DON’T USE COMMON RETURNS! Section 5 - Wiring Techniques Page 5-1 S1400CW Figure 5-1 - Field Wired Circuits With & Without A Common Return 5.2.2 Use of Twisted Shielded Pair Wiring (with Overall Insulation) For all field I/O wiring the use of twisted shielded pairs with overall insulation is highly recommended. This type of cable provides discrete insulation for each of the wires and an additional overall insulated covering that provides greater E.M.I. immunity and protection to the shield as well. S1400CW Page 5-2 Section 5 - Wiring Techniques 5.2.3 Grounding of Cable Shields DO NOT connect the cable shield to more than one ground point; it should only be grounded at one end. Cable shields that are grounded at more than one point or at both ends may have a tendency to induce circulating currents or sneak circuits that raise havoc with I/O signals. This will occur when the ground systems associated with multipoint connections to a cable shield have a high resistance or impedance between them and a ground induced voltage is developed (for what ever reason, i.e., man made error or nature produced phenomena). 5.2.4 Use of Known Good Earth Grounds ControlWave units should only have one connection to earth ground. For ControlWave and ControlWave MICRO Process Automation Controllers, ControlWave MICRO, ControlWave EFM Electronic Flow Meters, ControlWave GFC/XFC Gas Flow Computers and ControlWave I/O Expansion Racks, this connection is provided via the Ground Lug that is situated on the bottom of the unit. ControlWaveLPs require the installation of a ground lug, ground bus or ground plate/panel. Since ControlWave units are DC-based systems, grounding does not take into account AC power grounding considerations. Earth grounding the unit is absolutely necessary when the unit is equipped with a radio or modem. Additionally these units should be connected to earth ground when they are installed in areas that have frequent lightning strikes or are located near or used in conjunction with equipment that is likely to be struck by lightning or if struck by lightning may cause equipment or associated system failure. Earth Grounds must be tested and must be known to be good before connecting the ControlWave. Earth grounds must be periodically tested and maintained (see Section 4). 5.2.5 Earth Ground Wires Earth connections must utilize smoothly dressed large wire. Use AWG 3 or 4 stranded copper wire with as short a length as possible. Exercise care when trimming the insulation from the wire ends. Twists the strands tightly, trim off any frizzes and tin the ends with solder. The earth ground wire should be clamped or brazed to the Ground Bed Conductor (that is typically a standard AWG 0000 copper cable. The earth ground wire should be run such that any routing bend in the cable is a minimum 8-inch radius above ground or a minimum 12-inch radius below ground. 5.2.6 Working Neatly & Professionally Take pride in your work and observe all site and maintenance safety precautions. After properly trimming the stranded pair wire ends, twist them in the same direction as their manufacturer did and then tin them with solder. Install the tinned wire end into it’s connector and then secure the associated connector’s clamping screw. Remember to check these connections for tightness from time to time. If solid copper wire is used (in conjunction with the DC Power System or for Earth Ground) make sure that the conductor is not nicked when trimming off the insulation. Nicked conductors are potential disasters waiting to happen. Neatly trim shields and whenever possible, coat them to protect them and prevent shorts and water entry. Section 5 - Wiring Techniques Page 5-3 S1400CW Remember loose connections, bad connections, intermittent connections, corroded connections, etc., are hard to find, waste time, create system problems and confusion in addition to being costly. 5.2.7 High Power Conductors and Signal Wiring When routing wires, keep high power conductors away from signal conductors. Space wires appropriately to vent high voltage inductance. Refer to the National Electrical Code Handbook for regulatory and technical requirements. 5.2.8 Use of Proper Wire Size ControlWaves utilize compression-type terminals that accommodate up to #14 AWG gauge wire. A connection is made by inserting the bared end (1/4 inch max.) into the clamp beneath the screw and securing the screw. Allow some slack in the wires when making terminal connections. Slack makes the connections more manageable and minimizes mechanical strain on the PCB connectors. Provide external strain relief (utilizing Tie Wrap, etc.) to prevent the loose of slack at the ControlWave. Be careful to use wire that is appropriately sized for the load. Refer to equipment manufacturer’s Specs. and the National Electrical Code Handbook for information on wire size and wire resistance. After installing the field wiring, test each load to determine if the correct voltage or current is present at the load. If you know the resistance of the field wires (Circular Mills x Length) you should be able to calculate the load voltage. Conversely, if you know the minimum load voltage and current, you should be able to derive the maximum voltage loss that is allowable due to line resistance and then the correct wire size. Referring to Figure 5-2, a relay that is picked by 100 mA, with a loop supply voltage of 24V and a total line resistance of 20 ohms, the load voltage (voltage across the relay) should be: VL = VS - (VC + VC) where VC + VC = (RC + RC) I 22 = 24 - 2 where 2V = (20 Ω) x 0.1 A Figure 5-2 - Calculating Load Voltage due to Line Resistance 5.2.9 Lightning Arresters & Surge Protectors Use lightning arresters in association with any radio or modem equipped unit. BBI 9600 bps modems are equipped with surge protection circuitry. Lightning arresters or Antenna S1400CW Page 5-4 Section 5 - Wiring Techniques Discharge Units should be placed on the base of the antenna and at the point where the antenna lead (typically coax) enters the site equipment building. When a modem is used, a lightning arrester should be placed at the point where the phone line enters the site equipment building. If you use a modem (manufactured by other than BBI) it is recommended that you also install a surge suppressors or lightning arrester on the phone line as close to the modem as possible. Any unit interfaced to a radio or modem must be connected to a known good earth ground. 5.2.10 Secure Wiring Connections Make sure that all wiring connections are secure. In time wires that were once round will become flattened due to the pressure applied by screw compression type terminals and site vibrations. After a while these compression screws have a tendency to become loose. Part of a good maintenance routine should be to check and tighten all screws associated with wiring terminal connections. Avoid nicking the wire(s) when stripping insulation. Remember, nicked conductors will lead to future problems. Also remember to provide some cabling slack and strain relief. If installing stranded or braided wiring that has not been tinned, be sure to tightly twist the end (in the same direction as manufactured) and then trim off any frizzed wires. Section 5 - Wiring Techniques Page 5-5 S1400CW BLANK PAGE READER RESPONSE FORM Please help us make our documentation more useful to you! If you have a complaint, a suggestion, or a correction regarding this manual, please tell us by mailing this page with your comments. It's the only way we know we're doing our job by giving you correct, complete, and useful documentation. DOCUMENT NUMBER: S1400CW TITLE: ControlWaveTM SITE CONSIDERATIONS For EQUIPMENT INSTALLATION, GROUNDING & WIRING ISSUE DATE: APR., 2005 COMMENT/COMPLAINT: ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ Mail this page to: Bristol Babcock Inc. 1100 Buckingham Street Watertown, CT 06795 Attn: Technical Publications Group, Dept. 315 Bristol Babcock 1100 Buckingham Street Watertown, CT 06795 Phone: +1 (860) 945-2200 Fax: +1 (860) 945-2213 Website: www.bristolbabcock.com U.S.A. Locations: Northern Region Bristol Babcock Inc. 1100 Buckingham Street Watertown, CT 06795 Phone: +1 (860) 945-2381 Fax: +1 (860) 945-2525 [email protected] Helicoid Instruments 1100 Buckingham Street Watertown, CT 06795 Phone: +1 (860) 945-2218 Fax: +1 (860) 945-2213 [email protected] Gulf Coast Region Bristol Babcock Inc. 2000 Governor's Circle Suite F Houston, TX 77092-8731 Phone: +1 (713) 685-6200 Fax: +1 (713) 681-7331 Western Region Bristol Babcock Inc. 1609 South Grove Avenue Suites 106 & 107 Ontario, CA 91761 Phone: +1 (909) 923-8488 Fax: +1 (909) 923-8988 Southeast Region Bristol Babcock Inc. 317 S. North Lake Blvd. Suite 1016 Altamonte Springs, FL 32701 Phone: +1 (407) 740-7084 Fax: +1 (407) 629-2106 [email protected] [email protected] [email protected] Central Region Bristol Babcock Inc. 300 North Coit Road Suite 1300 Richardson, TX 75080 Phone: +1 (972) 238-8935 Fax: +1 (972) 238-8198 [email protected] Rocky Mountain Region Bristol Babcock Inc. 906 San Juan Blvd., Suite A Farmington, NM 87401 Phone: +1 (505) 320-5046 Fax: +1 (505) 327-3273 Communications Technology Group Bristol Babcock Inc. 317 S. North Lake Blvd. Suite 1016 Altamonte Springs, FL 32701 Phone: +1 (407) 629-9464 Fax: +1 (407) 629-2106 [email protected] [email protected] International Affiliates: Canada Bristol Babcock, Canada 234 Attwell Drive Toronto, Ont. M9W 5B3 Canada PH: 416-675-3820 FAX: 416-674-5129 [email protected] Mexico BBI, S.A. de C.V. Homero No. 1343, 3er Piso Col. Morales Polanco 11540 Mexico, D.F. Mexico PH: (52-55)-52-81-81-12 FAX: (52-55)-52-81-81-09 [email protected] United Kingdom Bristol Babcock Ltd. Blackpole Road Worcester, WR3 8YB United Kingdom PH: +44 (0) 1905 856950 FAX: +44 (0) 1905 856969 [email protected] Asia Pacific Bristol Babcock, Inc. PO Box 1987 Bunbury, Western Australia 6231 PH: +61 (0) 8 9791 3654 FAX: +61 (0) 8 9791 3173 [email protected] Victoria, Australia PH: +61 (0) 3 9384 2171 FAX: +61 (0) 3 8660 2501 Calgary Office Bristol Babcock, Canada 3812 Edmonton Trail N.E. Calgary, Alberta T2E 5T6 Canada PH: 403-265-4808 FAX: 403-233-2914 [email protected] RC Rev: 05-Feb-04 Villahermosa Office BBI, S.A. de C.V. Av. Plomo No.2 Bodega No. 1 - Ciudad Industrial Villahermosa, Tabasco 86010 Mexico PH: 52-993-353-3142 FAX: 52-993-353-3145 [email protected] Middle East Bristol Babcock Ltd. Blackpole Road Worcester, WR3 8YB United Kingdom PH: +44 (0) 1905 856950 FAX: +44 (0) 1905 856969 [email protected] ESDS Manual S14006 4/15/92 CARE AND HANDLING OF PC BOARDS AND ESD-SENSITIVE COMPONENTS BRISTOL BABCOCK BLANK PAGE ESDS Manual S14006 4/15/92 TABLE OF CONTENTS PAGE TOOLS AND MATERIALS REQUIRED 1 ESD-SENSITIVE COMPONENT HANDLING PROCEDURE 2 1. Introduction 2 2. General Rules 3 3. Protecting ESD-Sensitive Components 5 4. Static-Safe Field Procedure 6 5. Cleaning and Lubricating 8 6. Completion 10 TOOLS AND MATERIALS REQUIRED 1. Tools Anti-Static Field kit. It is recommended that an anti-static field kit be kept on any site where solid-state printed circuit boards and other ESD-sensitive components are handled. These kits are designed to remove any existing static charge and to prevent the build-up of a static charge that could damage a PC board or ESD-sensitive components. The typical anti-static field kit consists of the following components: 1. A work surface (10mm conductive plastic sheet with a female snap fastener in one corner for ground cord attachment). 2. A 15-foot long ground cord for grounding the work surface. 3. Wrist strap (available in two sizes, large and small, for proper fit and comfort) with a female snap fastener for ground cord attachment. 4. A coiled ground cord with a practical extension length of 10 feet for attachment to the wrist strap. Toothbrush (any standard one will do) 1 ESDS Manual #S14006 4/15/92 2. Materials ● Inhibitor (Texwipe Gold Mist ; Chemtronics Gold Guard, or equivalent) ● Cleaner (Chemtronics Electro-Wash; Freon TF, or equivalent) ● Wiping cloth (Kimberly-Clark Kim Wipes, or equivalent) ESD-SENSITIVE COMPONENT HANDLING PROCEDURE 1. Introduction Microelectronic devices such as PC boards, chips and other components are electrostatic-sensitive. Electrostatic discharge (ESD) of as few as 110 volts can damage or disrupt the functioning of such devices. Imagine the damage possible from the 35,000 volts (or more) that you can generate on a dry winter day by simply walking across a carpet. In fact, you can generate as much as 6,000 volts just working at a bench. There are two kinds of damage that can be caused by the static charge. The more severe kind results in complete failure of the PC board or component. This kind of damage is relatively simple, although often expensive, to remedy by replacing the affected item(s). The second kind of damage results in a degradation or weakening which does not result in an outright failure of the component. This kind of damage is difficult to detect and often results in faulty performance, intermittent failures, and service calls. Minimize the risk of ESD-sensitive component damage by preventing static build-up and by promptly removing any existing charge. Grounding is effective, if the carrier of the static charge is conductive such as a human body. To protect components from nonconductive carriers of static charges such as plastic boxes, place the component in static-shielding bags. This manual contains general rules to be followed while handling ESD-sensitive components. Use of the anti-static field kit to properly ground the human body as well as the work surface is also discussed. 2 ESDS Manual S14006 4/15/92 Table 1 Typical Electrostatic Voltages Electrostatic Voltages Means of Static Generation Walking across carpet Walking over vinyl floor Worker at bench Vinyl envelopes for work instructions Poly bag picked up from bench Work chair padded with poly foam 2. 10-20 Percent Relative Humidity 35,000 12,000 6,000 7,000 20,000 18,000 65-90 Percent Relative Humidity 1,500 250 100 600 1,200 1,500 General Rules (1) ESD-sensitive components shall only be removed from their static-shielding bags by a person who is properly grounded. (2) When taken out of their static-shielding bags, ESD-sensitive components shall never be placed over, or on, a surface which has not been properly grounded. (3) ESD-sensitive components shall be handled in such a way that the body does not come in contact with the conductor paths and board components. Handle ESD-sensitive components in such a way that they will not suffer damage from physical abuse or from electric shock. (4) EPROMS/PROMS shall be kept in anti-static tubes until they are ready to use and shall be removed only by a person who is properly grounded. (5) When inserting and removing EPROMS/PROMS from PC boards, use a chip removal tool similar to the one shown in the figure following. Remember, all work should be performed on a properly grounded surface by a properly-grounded person. 3 ESDS Manual #S14006 4/15/92 Typical Chip Removal Tool 4 (6) It is important to note when inserting EPROMS/PROMS, that the index notch on the PROM must be matched with the index notch on the socket. Before pushing the chip into the socket, make sure all the pins are aligned with the respective socket-holes. Take special care not to crush any of the pins as this could destroy the chip. (7) Power the system down before removing or inserting comb connectors/plugs or removing and reinstalling PC boards or ESD-sensitive components from card files or mounting hardware. Follow the power-down procedure applicable to the system being serviced. (8) Handle all defective boards or components with the same care as new components. This helps eliminate damage caused by mishandling. Do not strip used PC boards for parts. Ship defective boards promptly to Bristol Babcock in a staticshielding bag placed inside static-shielding foam and a box to avoid damage during shipment. ESDS Manual S14006 4/15/92 CAUTION Don't place ESD-sensitive components and paperwork in the same bag. The static caused by sliding the paper into the bag could develop a charge and damage the component(s). (9) 3. Include a note, which describes the malfunction, in a separate bag along with each component being shipped. The repair facility will service the component and promptly return it to the field. Protecting ESD-Sensitive Components (1) As stated previously, it is recommended that an electrically-conductive anti-static field kit be kept on any site where ESD-sensitive components are handled. A recommended ESD-protective workplace arrangement is shown on page 7. The anti-static safety kit serves to protect the equipment as well as the worker. As a safety feature, a resistor (usually of the one-megohm, 1/2-watt, current-limiting type) has been installed in the molded caps of the wrist strap cord and the ground cord. This resistor limits current should a worker accidently come in contact with a power source. Do not remove the molded caps from grounded cords. If a cord is damaged, replace it immediately. (2) Be sure to position the work surface so that it does not touch grounded conductive objects. The protective resistor is there to limit the current which can flow through the strap. When the work surface touches a grounded conductive object, a short is created which draws the current flow and defeats the purpose of the current-limiting resistor. (3) Check resistivity of wrist strap periodically using a commercially-available system tester similar to the one shown in the figure below: 5 ESDS Manual #S14006 4/15/92 Note: If a system checker is not available, use an ohmmeter connected to the cable ends to measure its resistance. The ohmmeter reading should be 1 megohm +/15%. Be sure that the calibration date of the ohmmeter has not expired. If the ohmmeter reading exceeds 1 megohm by +/- 15%, replace the ground cord with a new one. 4. Static-safe Field Procedure 6 (1) On reaching the work location, unfold and lay out the work surface on a convenient surface (table or floor). Omit this step if the table or floor has a built-in ESD-safe work surface. (2) Attach the ground cord to the work surface via the snap fasteners and attach the other end of the ground cord to a reliable ground using an alligator clip. (3) Note which boards or components are to be inserted or replaced. (4) Power-down the system following the recommended power-down procedure. (5) Slip on a known-good wristband, which should fit snugly; an extremely loose fit is not desirable. (6) Snap the ground cord to the wristband. Attach the other end of the ground cord to a reliable ground using the alligator clip. ESDS Manual S14006 4/15/92 (7) The components can now be handled following the general rules as described in the instruction manual for the component. (8) Place the component in a static-shielding bag before the ground cord is disconnected. This assures protection from electrostatic charge in case the work surface is located beyond the reach of the extended ground cord. C D ✰R E A F R G B R R EARTH GROUND FLOOR OF BUILDING LEGEND A - Chair with ground (optional) B - ESD protective floor mat (optional) C - Wrist strap D - ESD protective trays, etc. E - Ionizer F - Other electrical equipment G - Workbench with ESD protective table top ✰ NOTE: ALL RESISTORS 1M Ω +/-10% 1/2W 7 ESDS Manual #S14006 4/15/92 5. (9) If a component is to undergo on-site testing, it may be safely placed on the grounded work surface for that purpose. (10) After all component work is accomplished, remove the wrist straps and ground wire and place in the pouch of the work surface for future use. Cleaning And Lubricating The following procedure should be performed periodically for all PC boards and when a PC board is being replaced. CAUTION Many PC board connectors are covered with a very fine gold-plate. Do not use any abrasive cleaning substance or object such as a pencil eraser to clean connectors. Use only the approved cleaner/lubricants specified in the procedure following. WARNING Aerosol cans and products are extremely combustible. Contact with a live circuit, or extreme heat can cause an explosion. Turn OFF all power and find an isolated, and ventilated area to use any aerosol products specified in this procedure. (1) 8 Turn the main line power OFF. Blow or vacuum out the component. This should remove potential sources of dust or dirt contamination during the remainder of this procedure. ESDS Manual S14006 4/15/92 (2) Clean PC board connectors as follows: a. Review the static-safe field procedure detailed earlier. b. Following the ESD-sensitive component handling procedures, remove the connectors from the boards and remove the PC boards from their holders. c. Use cleaner to remove excessive dust build-up from comb connectors and other connectors. This cleaner is especially useful for removing dust. d. Liberally spray all PC board contacts with Inhibitor. The inhibitor: ● Provides a long lasting lubricant and leaves a protective film to guard against corrosion ● Improves performance and reliability ● Extends the life of the contacts ● Is nonconductive, and is safe for use on most plastics e. Clean the comb contacts using a lint-free wiping cloth. f. Lightly mist all comb contacts again with Inhibitor. NOTE: Do not use so much Inhibitor that it drips. g. (3) Repeat the above procedure for the other PC boards from the device. Cleaning PC edge connectors a. Use cleaner to remove excessive dust build-up from connectors. This cleaner is especially useful for removing dust. b. Liberally spray the outboard connector with Inhibitor. c. Lightly brush the outboard connector with a soft, non-metallic, bristle brush such as a toothbrush. 9 ESDS Manual #S14006 4/15/92 6. 10 d. Spray the connector liberally to flush out any contaminants. e. Remove any excess spray by shaking the connector or wiping with either a toothbrush, or a lint-free wiping cloth. Completion (1) Replace any parts that were removed. (2) Make sure that the component cover is secure. (3) Return the system to normal operation. (4) Check that the component operates normally. BLANK PAGE ControlWave I/O Expansion Rack Emerson Process Management Bristol, Inc. 1100 Buckingham Street Watertown, CT 06795 Phone: +1 (860) 945-2262 Fax: +1 (860) 945-2525 www.EmersonProcess.com/Bristol Emerson Electric Canada, Ltd. Bristol Canada 6338 Viscount Rd. Mississauga, Ont. L4V 1H3 Canada Phone: 905-362-0880 Fax: 905-362-0882 www.EmersonProcess.com/Bristol Emerson Process Management BBI, S.A. de C.V. Homero No. 1343, 3er Piso Col. Morales Polanco 11540 Mexico, D.F. Mexico Phone: (52-55)-52-81-81-12 Fax: (52-55)-52-81-81-09 www.EmersonProcess.com/Bristol Emerson Process Management Bristol Babcock, Ltd. Blackpole Road Worcester, WR3 8YB United Kingdom Phone: +44 1905 856950 Fax: +44 1905 856969 www.EmersonProcess.com/Bristol Emerson Process Management Bristol, Inc. 22 Portofino Crescent, Grand Canals Bunbury, Western Australia 6230 Mail to: PO Box 1987 (zip 6231) Phone: +61 (8) 9725-2355 Fax: +61 (8) 8 9725-2955 www.EmersonProcess.com/Bristol Customer Instruction Manual CI-ControlWaveEXP Oct., 2006 The information in this document is subject to change without notice. Every effort has been made to supply complete and accurate information. However, Bristol, Inc. assumes no responsibility for any errors that may appear in this document. If you have comments or questions regarding this manual, please direct them to your local Bristol sales representative, or direct them to one of the addresses listed at left. Bristol, Inc. does not guarantee the accuracy, sufficiency or suitability of the software delivered herewith. The Customer shall inspect and test such software and other materials to his/her satisfaction before using them with important data. There are no warranties, expressed or implied, including those of merchantability and fitness for a particular purpose, concerning the software and other materials delivered herewith. TeleFlow™ is a trademark of Bristol, Inc. The Emerson logo is a trade mark and service mark of Emerson Electric Co. Other trademarks or copyrighted products mentioned in this document are for information only, and belong to their respective companies, or trademark holders. Copyright (c) 2006, Bristol, Inc., 1100 Buckingham St., Watertown, CT 06795. No part of this manual may be reproduced in any form without the express written permission of Bristol Inc. ">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement