Autoglide CABRI-35P is a swing gate opener system designed for residential use, capable of automating single or dual leaf gates with a maximum weight of 350kg per leaf and a maximum width of 3.5 meters per leaf. It features a powerful 24V DC motor and a worm screw reduction gear, providing smooth and reliable operation. CABRI-35P comes with a range of accessories including photocells for obstacle detection, a flashing light for safety, and a radio transmitter for remote control.
advertisement
INSTRUCTIONS CABRI-20P
Page 1
SWING GATE OPENER
INDEX
Warnings 3. Control Box
1. Product Description and Application 4. Settings
1.1 Applications 4.1 Sw1 Dip Switch Setting
1.2 Description of the Automation. 4.1.1 Slowing Down Adjustment
1.3 Description of Devices
1.3.1 CABRI-20P Electromechanical
Gear Motors
1.3.2 Control Box
4.1.2 Over-Current Adjustment
4.1.3 Gate Auto Close Adjustment
4.1.4 Pedestrian Mode Adjustment
1.3.3 Photocells
1.3.4 Radio Transmitter
1.3.5 Flashing Light
1.3.6 Electric Latch with Stopper
2. Installation
2.1 Notes of Motors in Operation
2.1.1 Tools In Installing
2.1.2 Motors, Components and its
Installation in Illustration
4.1.5 Flashing Light Adjustment
4.2 Sw2 Dip Switch Setting
4.2.1 Photocell Adjustment
4.2.2 Close delay of Dual Gate
Operation Adjustment
4.2.3 Electric latch Adjustment
4.2.4 Deceleration Speed Adjustment
4.2.5 Operation Speed Adjustment.
4.2.6 Single and Dual Gate Adjustment.
2.2 Power connection
2.2.1 Notes for Power Connection
2.3 Installation 4.5 System Learning Process.
2.3.1 Preparation for Motor Installation 4.6 Gate Operation.
2.3.2 Installation of the Gear Motors
4.3 LED Indication
4.4 Transmitter Memorizing Process
2.3.3 Flashing Light
4.7 Gate Moving Logic.
4.8 Advanced Operation of the
Transmitter.
2.3.4 Photocells
2.3.5 Electric Latch and Stopper
5. Trouble Shooting.
6. Technical Characteristics.
INSTRUCTIONS CABRI-20P
Page 2
SWING GATE OPENER
Warnings
Please read this instruction manual carefully before the installation of gate-automated system.
This manual is exclusively for qualified installation personnel.
Autoglide
is not responsible for improper installation and failure to comply with local electrical and building regulations.
Keep all the components of CABRI-20P system and this manual for further
consultation
•
Be aware of the hazards that may exist in the procedures of installation and operation of the gate-automated system. Besides, the installation must be carried out in conformity with local standards and regulations
•
If the system is correctly installed and used following all the standards and regulations, it will ensure a high degree of safety
•
Make sure that the gates works properly before installing the gateautomated system and confirm the gates are appropriate for the application.
•
Do not let children operate or play with the gate-automated system.
•
Do not cross the path of the gate-automated system when operating.
•
Please keep all the control devices and any other pulse generator away from children to avoid the gate-automated system being activated accidentally.
•
Do not make any modifications to any components except that it is mentioned in this manual.
•
Do not try to manually open or close the gates before you release the gear motor.
•
If there is a failure that cannot be solved and is not mentioned in this manual, please contact qualified installation personnel.
•
Do not use the gate-automated system before all the procedures and instructions have been carried out and thoroughly read.
•
Test the gate-automated system weekly and have qualified installation personnel to check and maintain the system at least every 6-month.
•
Install warning signs (if necessary) on the both sides of the gate to warn the people in the area of potential hazards.
INSTRUCTIONS CABRI-20P
Page 3
SWING GATE OPENER
1. Product Description and Applications
1.1 Applications
CABRI-20P is applied for residential automation of single or dual leaf gate. CABRI-
20P has to be operated with electricity and it’s forbidden to be operated by back-up batteries for normal use. Back-up batteries are only allowed for emergent operation when there is a power failure, and the gear motors can be released by special keys to move the gate manually.
1.2 Description of the Automation
The following diagram of CABRI-20P typical installation describes some
terms and accessories of a gate automation system
Figure 1
1.3 Description of devices
CABRI-20P includes the accessories shown in figure 2. Please check the accessories the same as the package provided.
Attn: some accessories not included due to customization
•
2 CABRI-20P electromechanical gear motors with mounting brackets
•
1 pair of photocells.(one TX and one RX)
Figure 2
•
2 Radio transmitters, Flashing Light, Control Box, Electric Latch and Stopper
INSTRUCTIONS CABRI-20P
Page 4
SWING GATE OPENER
1.3.1 CABRI-20P Electromechanical Gear Motors
CABRI-20P consists of a worm screw reduction gear and a 24V DC motor.
The gear motor could be released manually by special release keys when there is a
power failure.
The gear motor is installed with two post brackets, one rear plate and one front plate for the installation
.
Figure 3
LIST OF SMALL PARTS CABRI-20P
Front Plate
Rear Plate
Post bracket
M8 *25L hex bolt
2pcs
2pcs
4pcs
4pcs
M8 self-locking nut
M12*25L hex bolt
M12 self-locking nut
Release key
4pcs
2pcs
2pcs
2pcs
1.3.2 Control Box
Control box consists of one control panel with incorporated receiver and one transformer. Provides the complete automation of the gear motors and other
accessories of CABRI-20P kit. To connect separate terminals on the control panel
and activate the gear motors and other accessories, the installation manual has to
be carefully read before handling.
Figure 4
LIST OF SMALL PARTS CABRI-20P
5*30 Screw
Nylon screw anchor
4pcs
4pcs
INSTRUCTIONS CABRI-20P
Page 5
SWING GATE OPENER
1.3.3 Photocells
The pair of Photocells has to be installed on the wall and connected to the control panel. The function of the photocells is to detect the obstacles found on the optical axis between the transmitter (TX) and the receiver (RX).
Figure 5
1.3.4 Radio Transmitter
Radio transmitter is used for the remote control of the gate movement. To use the transmitter, press and hold the button for 1 second. There are two buttons on the transmitter and (A) button is “open-stop-close mode” and (B) button is “pedestrian mode”.
1.3.5 Flashing Light
Flashing light is controlled by control box and blinks when the gate is moving.
The flashing light stops blinking when the gates finish opening or closing
Figure 7
INSTRUCTIONS CABRI-20P
Page 6
SWING GATE OPENER
1.3.6 Electric Latch and Stopper
Electric latch is used to lock the gate and it has to be used with stopper and installed
on the master gate.
Figure 8
LIST OF SMALL PARTS
M8*25L hex bolt
M8 self locking nut
Key
3pcs
3pcs
2pcs
2) Installation:
2.1 Notes of Motors in Operation
The
CABRI-20P gate openers are applicable to per leaf of 2.5 meters in width and
200 kg in weight which can be opened up to 110 degrees primarily for residential use; where the performance shall be influenced by the factors such as gate dimension, weight and climate that the driven torque is necessarily to be adjusted properly
.
2.1.1 Tools in Installing
Please make sure all tools and cables are ready and conform to the industrial
safety standard before installation. Please refer to Figure 9.
Figure 9
INSTRUCTIONS CABRI-20P
Page 7
SWING GATE OPENER
2.1.2 Motors, Components and Its Installation in Illustration
The installation procedure of CABRI-20P may be changed due to Various
accessories and quantities installed. The basic wiring diagram is shown in Figure 10.
No wiring cables for accessories are supplied with CABRI-20P.
Figure 10
2.2 Power Connection
CABRI-20P is required to connect two cores wires, which requires very low
voltage that no professionally trained personnel is required in installation; however, the
users are advised to read the installation manual carefully before going for it. After
getting to know all accessories and their positions, suggest starting from cable conduit
arrangement to prevent the cables from being broken or damaged.
2.2.1 Notes for Power Connection
1. The installation of power supply cable to the motor should be carried out by a qualified professional electrician.
2. The power supply cable of the motor should be equipped with short circuit protection and leakage protection.
3.
Please make sure to shut off the power before going installation or maintenance
.
2.3 Installation
2.3.1 Preparation for Motor Installation
CABRI-20P is not applicable to a gate which is inefficient or unsafe, neither to
solve the defects due to incorrect installation nor poor maintenance.
INSTRUCTIONS CABRI-20P
Page 8
SWING GATE OPENER
1)
Make sure the weight and dimensions of the gate conform to the operation range of
CABRI-20P. Don’t use CABRI-20P if the specifications do not meet the
requirements.
2). Make sure the gate structure conform to the criteria of automatic operation and
force regulations.
3). Make sure there is no serious friction existing in the opening or closing travel of the
gate leaves.
4). Make sure the gate is at horizontal level that the gate will not move aside at any
position.
5). Make sure the gate can bear the impact of the motor torque when it is installed on
any hole of the bracket which the surface is sufficiently sturdy.
6). Make sure the photo sensors are installed on flat surfaces to ensure the two ends of
receiving and transmitting corresponded to each other.
7). Check the dimensions of the motors as below.
Figure 11
8). Make sure to leave enough space when the gate is opening
Figure 12(Aerial View)
INSTRUCTIONS CABRI-20P
Page 9
SWING GATE OPENER
9).
If the gate is OPENED OUTWARD, please leave at least 70mm between the post
brackets and the gate.
Figure 13 (Aerial View)
Figure 14 (Aerial View)
10) Using the leaf-opening angle as criteria to make sure all criteria in Figure 15
can be met.
Figure 15
INSTRUCTIONS CABRI-20P
Page 10
SWING GATE OPENER
11). “C” value is 139mm.
12). “D” can be measured from the gate easily.
13). “A” = “C” + “D”
14). The value of “B” can be calculated from the value of “A” and the leaves opening
angle. Ex. If “A”=160mm with the leaves opening angle of 100 degrees, then the
value of “B” is approximate 190mm.
**Please make sure “B” and “A” are similar or the same in value that the leaves
can be operated smoothly, also to reduce the burden of the motor.
2.3.2 Installation of The Gear Motors
1. Choose the correct dimensions of the motors and position to be installed.
2. Check if the mounting surface the brackets to be installed is smooth, vertical
and rigid.
3. Arrange the cable conduit for power supply cable of the motors.
4. Loosen the screw and remove the cover of the motor as shown in Figure 16.
5. Place the leaves in the closed position
.
6. Refer to the distance of “B” in
Figure 17
, place the rear plate in the correct position on
the mounting surface.
Inspect if the distance is proper as shown in Figure 22 i.e. the
position the front plate of the motor to be installed.
7. Place two post brackets on the surface to be installed and mark the drilling points,
then drill minimum diameter of 8mm holes by four on the mounting surface to be
installed and fasten up the brackets with screws and washers.
8. Please make sure the front plate is completely installed horizontally.
INSTRUCTIONS CABRI-20P
Page 11
SWING GATE OPENER
.
9. Refer to Figure 20, the distance between front plate of the motor and rear plate is
798mm (CABRI-20P), the difference in height is 15.5mm (CABRI-20P).
10. Clamp and fix the motor front plate on the door temporarily
.
Figure 20
Figure 21
11. Lift up the motor and insert the screws into the front plate.
12
.
Lift the motor overhead and push the gate to the end until the screw holes of the
motor end matches the holes on the rear plate. Fasten the motor to the rear plate
with the bolt as shown in Figure22.
INSTRUCTIONS CABRI-20P
Page 12
SWING GATE OPENER
13. Fasten the nut tightly and loosen it for half round for motor supporting in rotating.
14. Fasten the motor front end to the front plate with the bolt (A) and nut (B) tightly.
Fully tighten the screw.
15. Use appropriate key to release the gear motor.
16. Try to push the released gate and make sure the motor can be manually moved
easily.
17. Make sure the motor front plate can be fastened on the gate to be installed
permanently.
18. Use appropriate Key to fasten the gear motor again.
19. Loosen the plastic nut under the power cable of the motor end, and penetrate the
power cable through the nut and screw it up.
20. Connect the motor power cable as shown in Figure23.
22. Close the gear motor cover by tightening the two screws as shown in Figure24
Figure 23 Figure 24
CABRI-20P
23.
Gear Motor Release
1). Insert the release key to the release slot Figure25.
2). Turn the release key anti-clockwise Figure26.
3). Pull out the release bar Figure27.
4). Turn the release key clockwise to fix the release bar, the release bar has to be in
pulled out position when you turn the release key clockwise Figure28.
5). The turning direction will be reversed for right motor
INSTRUCTIONS CABRI-20P
Page 13
SWING GATE OPENER
2.3.3 Flashing Light
1) Decide the installation position of the flashing light. The flashing light has to be installed near the gate and easy to be seen by users and passersby. The flashing light can be installed horizontally or vertically.
Figure 2.3.3 (1).
2) Unscrew the four screws on the light base and separate the base with the bottom as shown in
Figure 2.3.3 (2).
3) Connect the wires and penetrate the wires into the hole of the base.
Figure 2.3.3 (3).
4) Drill the holes in the wall and fix the bottom to the wall by three screws.
Figure 2.3.3 (4)
Figure 2.3.3(1) Figure 2.3.3(2) Figure 2.3.3(3) Figure 2.3.3(4)
5). Connect the two wires of the light to the PCB terminals and place the wires into the
conduit if necessary. See Figure 2.3.3 (5).
6). Tighten the four screws back on the light base. Figure 2.3.3 (6)
7). Replacing the bulb set. See Figure 2.3.3 (7)
7.1) Unscrew the flashing light wires from the PCB terminals and make sure the
power of the light is off.
7.2) Release the three screws (A) (B) (C) of the flashing light cover.
7.3) Separate the flashing light cover and replace the bulb set with a new one.
7.4) Tighten the three screws (A) (B) (C) of the flashing light cover.
Figure 2.3.3(5) Figure 2.3.3(6) Figure 2.3.3(7)
INSTRUCTIONS CABRI-20P
Page 14
SWING GATE OPENER
2.3.4 Photocells
1). Open the cover Figure 2.3.4 (1) .and connect wires Figure 2.3.4 (2).
2). Mounted the receiver and transmitter on the proper position Figure 2.3.4 (3)
3). Ensure there are no obstacles between receiver and transmitter. For optimal
efficiency, the receiver and transmitter should be properly aligned.
4). Power-up the photocells and make sure the LED light on receiver and
transmitter are ON
Figure 2.3.4(1) Figure 2.3.4(2)
Figure 2.3.4(3)
2.3.5 Electric Latch and Stopper
1.
Stopper
:
1). Before installing the stopper, please make sure the gates are in close positions and
the surface to be installed is flat.
2). Place the stopper on the ground using the bottom as reference, and mark the 3
drilling points.
See Figure 2.3.5 (1) for the gate opened inward.
See Figure 2.3.5 (2) for the gate opened outward.
INSTRUCTIONS CABRI-20P
Page 15
SWING GATE OPENER
Figure 2.3.5(1) Figure 2.3.5(2)
3
). Drill the 3 marked points, and then securely attach the stopper to the ground with
screws and washers.See Figure 2.3.5 (3)
Figure 2.3.5(3)
2. Electric Latch. (If the gate is opened outward)
1)
If the gate is opened outward, please change the spring inside and screw it in the
different place. See Figure 2.3.5(4),
Figure2.3.5(5),
Figure2.3.5(6), Figure2.3.5(7)
Figure 2.3.5(4) Figure 2.3.5(5) Figure 2.3.5(6)
Unscrew the screws Take the casing off The location of the spring
INSTRUCTIONS CABRI-20P
Page 16
SWING GATE OPENER
Figure 2.3.5(7)
Change the spring and screw in different place
2
). Weld the back plate of the electric latch to the surface on the master gate.
See Figure 2.3.5(8).
Please avoid melting the wires by the heat of the fixed plate
Figure 2.3.5(8)
For the gate opened inward
Figure 2.3.5(9)
For the gate opened outward
3). The gap between the bottom of electric latch and the stopper should be less than 7mm.
Figure 2.3.5(10).
4). Connect the wires of the electric latch to the terminal LAT (+) and LAT (-) on the PCB.
Figure 2.3.5(10)
For the gate opened inward.
Figure 2.3.5(11)
For the gate opened outward
INSTRUCTIONS CABRI-20P
Page 17
SWING GATE OPENER
AUTOGLIDE CABRI-20P
3) Control Box
Control Box Installation
1. Decide the installation position of control box first, it is suggested to be installed near the gate and should be protected from possible damage. Be aware of the motor cable length before deciding the installation position.
2. Remove the cover by unscrewing the four screws on the cover. Figure 1(1).
3. Use a screwdriver to puncture the holes beneath the bottom of the control box.
Figure 1(2).
4. Secure it on the wall. Figure 1(3).
Figure 1(1) Figure 1(2) Figure 1(3)
INSTRUCTIONS CABRI-20P
Page 18
SWING GATE OPENER
5. Wiring Connection:
Prepare all the wires of the accessories beforehand and connect the wires to the gear motors and accessories on the PCB as shown in Figure 1(4). All of the wiring connections of the accessories are not requested to distinguish the positive (+) and the negative (-) polarity.
1). Flashing light: Connect the two wires from the flashing light to the terminal
L+ and L- on the PCB.
2). Electric Latch: Connect the two wires from the electric latch to the terminal
Lo + and Lo- on the PCB.
3). Gate openers: Refer to Figure 1(4) and connect the wires separately to the
terminals on the PCB.
Motor 1:
Connect the motor wire (White +) to the terminals Mo1 +, and
(Yellow -) to the Mo1-.
Motor 2:
Connect the motor wire (White +) to the terminals Mo2 +, and
(Yellow -) to the Mo2 -.
Notes:
For gates opened outward.
Motor 1:
Connect the motor wire (Yellow -) to the terminals Mo1 +, and
(White +) to the terminals Mo1-.
Motor 2:
Connect the motor wire (Yellow -) to the terminals Mo2 +, and
(White +) to the terminals Mo2
-.
4). Photocells: See Figure 1(4)
(A) installed one set Photocell to FO1, SW3 setting as below:
3. Ph_conn1 > OFF and 4. Ph_conn2 > ON
(B) installed one set Photocell to FO2, SW3 setting as below:
3. Ph_conn1 > ON and 4. Ph_conn2 > OFF
(C) installed two sets Photocell, SW3 setting as below:
3. Ph_conn1 > OFF and 4. Ph_conn2 > OFF
(D) No Photocell has been installed, SW3 setting as below:
3. Ph_conn1 > ON and 4. Ph_conn2 > ON
INSTRUCTIONS CABRI-20P
Page 19
SWING GATE OPENER
Figure 1(4)
INSTRUCTIONS CABRI-20P
Page 20
SWING GATE OPENER
4. Settings
4.1 Sw1 Dip Switch Setting
4.1.1 Slowdown Adjustment (Dip 1.Slow)
ON: The gear motors do not slow down before the gates completely close or open.
OFF: The gear motors slow down before the gates completely close or open
.
4.1.2 Over-current Adjustment (Dip 2.Over C1 & Dip 3. Over C2)
OVER C1 OVER C2 Current (Amp)
Dip Switch 2 OFF Dip Switch 3 OFF 2A
Dip Switch 2 OFF Dip Switch 3 ON
Dip Switch 2 ON Dip Switch 3 OFF
Dip Switch 2 ON Dip Switch 3 ON
3A
4A
5A
INSTRUCTIONS CABRI-20P
Page 21
SWING GATE OPENER
4.1.3 Gate Auto close Adjustment
(Dip 4. Auto C1, Dip 5. Auto C2 & Dip 6. Auto C3)
Auto C1 Auto C2 Auto C3
Dip switch 4 OFF Dip Switch 5 OFF
Effect
Dip Switch 6 OFF No auto-close
Dip switch 4 OFF
Dip switch 4 OFF
Dip switch 4 OFF
Dip switch 4 ON
Dip Switch 5 OFF
Dip Switch 5 ON
Dip Switch 5 ON
Dip Switch 5 OFF
Dip Switch 6 ON
Dip Switch 6 ON
Dip Switch 6 OFF
Dip Switch 6 OFF
3 sec.
10 sec.
20 sec.
40 sec.
Dip switch 4 ON
Dip switch 4 ON
Dip Switch 5 OFF
Dip Switch 5 ON
Dip Switch 6 ON 60 sec.
Dip Switch 6 OFF 120 sec.
Dip switch 4 ON Dip Switch 5 ON Dip Switch 6 ON 360 sec.
Note : Auto-Close mode activates when the gates move to the end position or stopped manually. If the transmitter or push button is activated before the auto-close counting, the gate will close immediately.
4.1.4 Pedestrian Mode Adjustment (Dip 7.P Mode)
ON: Press button B on the remote to operate to pedestrian mode by open single gate to
45 degree
OFF: The pedestrian mode is disabled. Single gate will fully open and close
.
4.1.5 Flashing Light Adjustment (Dip 8.Light)
ON: The flashing light blinks for 3 seconds before the gate moves, and blinks
simultaneously during the movement.
OFF: The flashing light blinks and the gate moves simultaneously.
4.2 Sw2 Dip Switch Setting
4.2.1 Photocell Adjustment (Dip 1.Photo1, Dip 2.Photo2)
1. SW2_2, SW2_1: OFF OFF
Position of Gate When safety devices are activated
Type of Safety Device
Safety Device2: Safety Device1 :
Photocell-OPEN Photocell-CLOSE
FULLY CLOSED Open not allowed No effect
FULLY OPENED No effect
STOP DURING MOVING Open not allowed
Reload automatic closing time
Reload automatic closing time
CLOSING
OPENING
INSTRUCTIONS CABRI-20P
No effect
Close
Page 22
Open
No effect
SWING GATE OPENER
2. SW2_2, SW2_1: OFF ON
Position of Gate
Type of Safety Device
When safety devices are activated
Safety Device2 : Safety Device1 :
FULLY CLOSED
Safety Edge
Open not allowed
Photocell-CLOSE
No effect
FULLY OPENED
Reload automatic closing time
STOP DURING MOVING
Locks
Reload automatic closing time
CLOSING
Reverse to open for 2 seconds Open
OPENING
Reverse to clsoe for 2 seconds No effect
3. SW2_2, SW2_1: ON OFF
Position of Gate
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
When safety devices are activated
Safety Device2: Safety Device1 :
Opening Device
Open
Photocell-CLOSE
No effect
Reload automatic closing time
Open Reload automatic closing time
Open
No effect
Open
No effect
4. SW2_2, SW2_1: ON ON
Position of Gate
Type of Safety Device
Safety Device2:
FULLY CLOSED
When safety devices are activated
Safety Device1 :
Photocell-OPEN/CLOSE Photocell-CLOSE
Open not allowed No effect
FULLY OPENED
CLOSING
STOP DURING MOVING
Close not allowed, Open for 2 seconds when auto closing is ON
Close not allowed
Locks
Open
OPENING
Stop No effect
4.2.2
Close Delay of Dual Gate Operation Adjustment (Dip 3.Delay1, Dip 4.Delay2)
Close/Open delay of two leaves of gate can be adjusted from 2 to 6 seconds
Dip3. Delay 1
OFF
ON
OFF
ON
DIP switch
Dip4. Delay 2
Open Delay
OFF
OFF
ON
ON
2 sec
2 sec
3 sec
3 sec
INSTRUCTIONS CABRI-20P
Close Delay
3 sec
4 sec
5 sec
6 sec
Page 23
SWING GATE OPENER
4.2.3
Electric Latch Adjustment (Dip 5.Latch)
ON: The master leaf will move toward closing direction for 0.25 second once
command the remote, then unlock the latch to open the gate.
OFF: Once command the remote, the the latch will be unlocked to open the gate
immediately
4.2.4 Decelaration Speed Adjustment of the Gear Motors (Dip 6. D Speed
)
ON: The speed is70% output of the full speed.
OFF: The speed is 50% output of the full speed.
4.2.5 Operation Speed Adjustment of the Gear Motors (Dip 7.O Speed)
ON: The speed is 100% output of the full speed.
OFF: The speed is 70% output of the full speed
.
4.2.6
Single and Dual Gate Operation Adjustment (Dip 8.Ds/set)
ON: Dual Gates operation in system learning and normal operation.
OFF: Single Gate operation in system learning and normal operation
.
4.3 LED Indication
LED1 System Learning:
LED1 is always ON when the system learning in not completed.
LED1 blinks once when single-gate learning is completed ;
LED1 blinks twice when dual-gate learning is completed.
LED 2 RF :
If the switch of the transmitter, key selector, or the push button is activated, LED2 will be on.
LED 3 Photocells 1 :
LED3 will be on when the first pair of the photocells are activated.
LED 4 Photocells 2
: LED4 will be on when the second pair of the photocells are activated.
LED 5 RF Indicator :
LED5 will be on when RF signal is received.
INSTRUCTIONS CABRI-20P
Page 24
SWING GATE OPENER
4.4 Transmitter Memorizing Process
Press “RF-learn” button for 2 seconds, and the Blue LED is on; then press the
transmitter (A) button; the Blue LED will blink twice and then be off. The system
learning is complete.
4.5
System Learning Process
! CAUTION: Before proceeding to system learning, the transmitter memorizing
process has to be completed.
Press “SYS-learn” button for 2 seconds, after press button (A) on the remote. System
learning will be executed step by step as followings: Wait for the learning process to be
completed without any interruption.
A. Dual Gate:
1
Slave Gate Close
→
2
Master Gate Close
→
3
Master Gate Open
→
4
Slave Gate Open
→
5
Slave Gate Close
→
6
Master Gate Close
.
INSTRUCTIONS CABRI-20P
Page 25
SWING GATE OPENER
B. Single Gate:
1 Master Gate Close
→
2 Master Gate Open
→
3 Master Gate Close
! Beware: The system learning process for single gate takes more than dual gate for around 1 min, wait for the gate to complete the learning process.
4.6 Gate Operation
Press the button “A” on the transmitter for dual-gate operation.
Press the button “B” on the transmitter for single-gate operation in either single-gate or dual-gate installation
.
4.7 Gate-moving Logic
(A) In gate-opening phase: The gates stop if the transmitter/push button is activated, and close when the transmitter/push button is reactivated.
(B) In gate-closing phase: The gates stop if the transmitter/push button is activated, and open when the transmitter/push button is reactivated.
(C) In gate-opening or gate-closing phase: For safety purpose, the gate stop if
encountering obstacles
4.8 Advanced Operation of the transmitter (SW3 Dip1/2 Remote1 &
Remote 2)
INSTRUCTIONS CABRI-20P
Page 26
SWING GATE OPENER
5. Trouble Shooting
Overheated Back-up Batteries
The gate doesn’t move when pressing the button of the transmitter
Check the wiring connection of the batteries.
1. Check if LED3 or 4 is “ON”.
2. Check if the voltage of the batteries is below 22V.
3. Check if LED1 is “ON”.
4. Make sure all the wiring connections are firmly connected to the terminals on the PCB.
5. Make sure the fuse is workable
The gate only moves a little distance when pressing the button of the transmitter.
Make sure the wiring connection of the hall sensor is firm.
Transmitting distance is too short
The gear motors run very slowly
Make sure the connecting terminals of the Antenna is firm.
Check the dip switch setting of the speed adjustment.
The Flashing light does not work
The leaves shall be closed instead of opening
The leaves suddenly stop during moving
The leaves does not move or only move toward one direction if the wiring connection of the flashing light is correct
Change the polarity connection of the positive (+) with the negative (-) of the gear motors.
1. Check if the “RESET” socket is activated.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the hall sensor wiring connection is firm.
4. The GND terminal of the photocells on the PCB must be short-circuited if no photocells installed.
5. Make sure the fuse is workable.
1. Check if the “RESET” socket is activated.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the hall sensor wiring connection is firm.
4. The GND terminal of the photocells onthe PCB must be short-circuited if no photocells installed.
The master gate closes to the end first and the slave gate stops, the flashing light blinks fast for five seconds.
Cut off the AC input power and the output of the batteries. Release the master gate and slave gate manually, then open the master to the end and close the slave gate to the end by hand, then power the whole unit by connecting the AC and battery terminals.
The gear motors does not run and the relay is noisy when operating the gate opening and closing
Check if the fuse is burned.
INSTRUCTIONS CABRI-20P
Page 27
SWING GATE OPENER
6. Technical Characteristics
6.1 CABRI-20P
6
CABRI-20P
Motor
Gear type
24Vdc motor with mechanical release
Worm gear
Peak thrust
Nominal thrust
Stroke length
2000N
1500N
400mm
Power supply
Maximum operating current
Maximum gate weight
Maximum gate length
Duty cycle
Operating Temperature
Dimension
Weight
24Vdc
4.2A for maximum 10 seconds.
200 kg per leaf
2.5 meters
20%
-20
℃
799mm * 98mm * 170mm
3.6kg
~+50
℃
6.2 Control Box
Application
Main power supply
Back-up battery
Transformer
Receiver board
Installation
Operating Temperature
Dimension
6.3 Photocells
Detection type
Operating distance
Response time
Input voltage
Operating Temperature
Protection class
Dimension
6.4 Flashing Light
Application
Lamp
Operating Temperature
Installation
Dimension
INSTRUCTIONS CABRI-20P
For CABRI-20P power supply
230Vac/110Vac, 50Hz/60Hz
2pcs of batteries for emergency operation, 1.2A each
4.2A, 24V
Through beam
25 meters
100ms
IP54
-20
℃
AC/DC 12~24V
-20
℃
~+60
℃
~+50
℃
96mm * 45mm * 43mm
24Vdc Halogens bulb
205mm * 80mm * 75mm
horizontally or vertically installed
433.92MHz; 200 transmitters memory
Wall mounted vertically
-20
℃
~+50
℃
275mm * 195mm * 102mm
For warning purpose during leaves movement
Page 28
SWING GATE OPENER
6.5 Radio Transmitter
Application
Frequency
Coding
Buttons
Power Supply
Operating Temperature
Dimension
6.6 Electric Latch
Application
Power Supply
Operating Temperature
Operating Current
Dimension
Radio transmitter for remote control of CABRI-20P
433.92Mhz
24Vdc
-20
5A
℃
Rolling code
~+50
2, for single-gate or dual-gate operation
3V with one CR2032 button type lithium battery
-20
℃
~+50
℃
71.5mm * 33mm * 14mm
For locking the gate.
℃
61mm * 55mm * 120mm
Proprietary Intellectual Property, Do not Distribute without authorization.
All rights Reserved- Copyright@2015 Autoglide.
www.autoglideglobal.com
INSTRUCTIONS CABRI-20P
Page 29
SWING GATE OPENER
advertisement
Related manuals
advertisement