XT-iP 210/620/730 GPRS Control Panel

I N S T A L L M A N U A L

Doc. - Ref. 230-XT-iP

Last modification date : June 2014

Firmware version : XLP.04.04.05.XXX and later

www.videofied.com

Introduction

I N S T A L L M A N U A L

Description

The XT-iP is a fully wireless alarm system. It can be powered by standalone batteries or connected to a power supply. This panel is intended mainly for residential and commercial markets.

With the Motion Viewers™ and Videofied® range of products, the XT-IP panel provides video verification in case of intrusion.

The XT-iP panel has three wired programmable inputs and two wired programmable outputs. Thanks to the

Mapping feature, the programmable inputs can be configured to trigger a video.

For specific applications, the XT-iP alarm system offers the possibility to increase its Radio and/or GPRS performances through the connection of externally wired antennas.

Technology

The XT-iP alarm panel, like all Videofied devices, uses the S2View® patented technology. Which is an interactive wireless and AES encrypted technology ensuring signal integrity and optimal security.

The reliability of the signal is guaranteed thanks to the two-way radio frequency transmissions with all the peripherals of the Videofied® product line.

The integrated antennas allow the system to be totally wireless, thus preventing from the system beeing inelegant and cumbersome, and eliminating the installation problems.

The jamming detection feature identifies any intentional jamming from a third party. On the other hand, the supervision feature consists of transmitting signals between every device of the system and the alarm panel

XT-iP. Through the supervision, the detectors transmit every 8 minutes a presence signal.

The entire RSI VIDEO TECHNOLOGIES team wishes you a successful installation.

www.videofied.com

2

Summary

I N S T A L L M A N U A L

Introduction............................................................................................................2

Summary...................................................................................................3

1. XT-iP Panel setup...............................................................................................4

1.1 RJ45 cable connection..............................................................................................4

1.2 SIM card installation.................................................................................................4

1.3 Panel mounting.........................................................................................................5

1.4 Powering and initialization.........................................................................................6

1.5 Pairing the remote keypad.........................................................................................6

2. XTENDER Mode...............

..........................................................................................

7

3. XT-iP Panel programming

...........................................................................................

8

ETHERNET parameters configuration...............................................................................12

XTENDER mode configuration.........................................................................................14

4. XT-iP features guide...............

.................................................................................

16

4.1 Get to access level 4..............................................................................................................16

4.2 How to Arm/Disarm the system................................................................................................16

4.3 Arming and Siren Mode Configuration...............................................................................17

4.4 Manage badges and access codes...........................................................................................18

4.5 Delete the keypad or any other device..................................................................................20

4.6 Read the event log....................................................................................................................21

4.7 Programmable inputs and outputs............................................................................................21

4.8 Golden rules...............................................................................................................................22

5. Ethernet parameters.

................................................................................................

23

6. Transmitted events list

.............................................................................................

24

7. 2G3G error codes...

...................................................................................

.............25

8. Technical specification and security notes

............................................................

26 www.videofied.com

3

1. XT-iP Panel setup

1.1 RJ45 cable connection

Connect the RJ45 cable to the Ethernet port.

When the panel attempts a transmission via Ethernet, a red

LED on the connector will flash. This will allow the installer to check whether the panel is connected to a valid network.

Do not touch the RJ45 cable when the panel is powered.

I N S T A L L M A N U A L

1.2 SIM Card Installation

Before removing the front cover from its box, put the SIM card on the plastic base (take care to respect the right orientation).

DO NOT insert or remove the SIM card while the panel is powered.

www.videofied.com

4

1. XT-iP Panel setup

1.3 Panel mounting

I N S T A L L M A N U A L

Bracket holes

Fix the back casing on the wall using the three mounting holes illustrated above.

Mounting the panel is not required for programming.

www.videofied.com

5

1. XT-iP Panel setup

I N S T A L L M A N U A L

1.4 Powering and initialization

• Connect the mains power supply and insert the 4 alkaline backup batteries.

• Press and hold the PROGRAMMING BUTTON for 10 seconds, until the indicator LED blinks twice.

• The panel is now reset, a CMA, XMA or XMB has to be enrolled to configure the panel.

Alkaline batteries Programming button Ethernet Connector

Providing that Ethernet connectivity is not used, the XT-iP panel can be powered by 4

LSH20 Lithium, instead of mains power supply with alkaline backup batteries.

1.5 Pairing the remote keypad

• Press briefly the XT-iP programming button and release for the enrollment of a programming keypad. The indicator LED will blink once.

• Insert all 3 LS14500 Lithium batteries into the keypad.

• Do not mount the keypad. It will displays one of the following screens:

RSI (c) 2013 videofied.com

or

<=========XX=========>

• Press on both CLR

and

ESC NO keys at the same time

and release. The indicator

LED on the keypad will blink rapidly. Wait for the keypad to pair.

• If the keypad doesn’t pair up with the panel

and shows «XX», it certainly means that it is still paired to another system and needs to be reset. Take the batteries out, and press repeatedly on the keypad tamper switch for 30 sec to 1 minute. Then proceed to the above steps.

www.videofied.com

Mains Power Supply

6

2. XTENDER Mode

I N S T A L L M A N U A L

The XT-iP panel can be used as standard standalone alarm system but it can also be connected to an existing alarm system capable of latching a 9-12Vcc* voltage used for its arming/disarming.

2.1 Standalone Mode

In this functioning mode, the XT-iP panel works as a standard hybrid alarm system with 25 wireless peripherals and 3 programmable inputs.

It is a totally standalone alarm system.

2.2 XTENDER Mode (From the host)

Existing Host panel

Arming O/P 2

Arming O/P 1

When the XT-iP panel is used in XTENDER mode, the system will only be able to arm and disarm by latching 9-12Vcc to its arming inputs

Arming Input 1 and/or Arming Input 2.

When the voltage switches to 0V, the panel will disarm automatically.

On a programmed panel, you can choose between standalone and XTENDER modes from the menu :

CONFIGURATION

(LVL 4) > GENERAL PARAMETERS > XTENDER

www.videofied.com

*When using an XT-iP in

XTENDER mode, the panel has to be powered by the mains power supply.

7

3. XT-iP Panel Programming

Keypad Display

KEYPAD 1

RECORDED

OK or YES

< - LANGUAGE : - >

ENGLISH (UK) for language selection

OK or YES

RADIO RANGE TEST?

OK or YES

RF TEST x/9

Please wait

RF TEST

9/9

OK or YES

RADIO RANGE TEST?

ESC

NO

INSTALLER CODE

4 TO 6 DIGITS

THEN OK/YES

INSTALLER CODE :

OK or YES

CONFIRM CODE

OK or YES

I N S T A L L M A N U A L

Actions and comments

The system can also be programmed in : french, italian, german, dutch, spanish, swedish, portuguese, danish, czech and polish.

The language can be changed at any time once the panel is programmed in the MAINTENANCE menu.

The Radio Range test must be run during the device learning process in order to ensure proper pairing with the control panel. This test measures the strength of communication between the device and the control panel. The keypad will display a real time radio range value on a scale of 9.

To receive the most accurate results you must run the radio range test for at least 30 seconds.

Result must be 8 out of 9 or better for reliable transmission.

Using the Alphanumeric Keypad, enter the Installer Code of your choice.

The Installer Code will be used for all future maintenance and configuration.

This code is important to keep track of.

There is no back door or Default codes to the system

Please refer to the restriction rules for codes (Chapter 4.4).

Some codes are already used by default and therefore cannot be used.

www.videofied.com

8

3. XT-iP Panel Programming

I N S T A L L M A N U A L

Keypad display Actions and comments

CODE NAME :

OK or YES

ACCESS 1

REGISTERED

Please wait

ADJUSTING DATE

AND TIME

DATE (YEAR):

12/ /

To set the year

OK or YES

DATE (MONTH):

13/01/

To set the month

OK or YES

You may proceed in the same way for:

Day

, Hour and Minutes.

13/10/14 10:47

ENTRY COMPLETE !

CONNECTED TO

MONITOR. STATION?

OK or YES

ESC

NO

ACCOUNT NUMBER :

ACCOUNT NUMBER :

567001

OK or YES

You may name the installer code using the Alphanumeric

Keypad.

If using automatic setting (called installer default list), enter the name of the list.

Warning

: If the wrong installers list name is used it cannot be set later, the system must be defaulted.

Leaving the name blank by pressing

ESC NO

, it will be named ‘ACCESS 1’ by default.

Use the Alphanumeric Keypad to enter in a 4-8 digit account number provided by the Central Station.

www.videofied.com

9

3. XT-iP Panel Programming

Keypad display

PERIODIC TEST

PERIODIC TEST :

24 HOURS

To select periodicity

OK or YES

TEST (hour) :

04:

OK or YES

TEST (minutes) :

04:15

OK or YES

ESC

NO

CODE/STATE

MODIFICATION?

OK or YES

Wait

CODE/STATE

MODIFICATION

Events list

ESC

NO

SERVER

ADDRESSES ?

OK or YES

I N S T A L L M A N U A L

Actions and comments

Test Periodicity: 1 hour, 12 hours, 24 hours, 48 hours, 7 days or no tests.

We suggest a 24 hours periodic test call.

The CODE/STATE MODIF. menu is to configure the transmitted events to the monitoring station, use the arrow keys to toggle between events and

OK or YES

to modify.

ALARM: event transmitted upon occurrence.

ALARM/END: event is transmitted on occurrence and on event restoral.

NOT TRANSMITTED: event is not transmitted, however it will appear on the keypad.

Please liaise with your Monitoring Station to ensure that the requested events to transmit are correctly set.

www.videofied.com

10

3. XT-iP Panel Programming

ESC

NO

2G3G

PARAMETERS ?

ESC

NO

2G3G LEVEL ?

OK or YES

TEST IN PROGRESS

END = OK/YES

2G3G LEVEL

5/5

OK or YES

2G3G LEVEL ?

ESC

NO

IP1 ADDRESS

0.0.0.0

ESC

NO

SERVER

ADRESSES ?

ESC

NO

STRATEGY:

ETH+2G3G

OK or YES

2G3G

PARAMETERS ?

OK or YES

APN CODE internet-entrepr

I N S T A L L M A N U A L

DOMAIN NAME 1

PORT 1

888

The IP1 address, Domain name 1 and/or Port 1 are provided by the monitoring station.

Leave Port details at 888 unless otherwise instructed.

Press

OK or YES

to enter/modify the parameter then

OK or YES

for validation.

WARNING : You will use either an IP adress or a Domain name but not both, leave the

Domain name

blank if an IP adress has already been entered.

Press on the right arrow to configure IP/Domain name 2 and PORT2 (for the back-up server), and IP/Domain name TMT and PORT TMT (to configure remote maintenance server).

How the alarms and videos are transmitted to the monitoring station ?

ETH+2G3G : Ethernet transmission with GPRS backup.

2G3G : GPRS transmission only (if the Ethernet connection is not used).

ETH : Ethernet transmission only (only if GPRS is not used).

Warning : the transmission mode “Ethernet only” is not recommended.

USER NAME orange

PASSWORD orange

The APN Code (Access Point Name), User Name and Password are supplied by the mobile operator. Please make sure you have entered the code exactly as indicated by your local SIM card operator.

Press

OK or YES

to enter/modify the parameter then

OK or YES

for validation.

Note: When entering your SIM card settings, both APN codes, username and password fields are case sensitive! It makes a difference between UPPER and lower case letters.

To switch between UPPER and lower case, use the M/m key from CMA keypad or hold a digit key (0-9) for XMA/XMB.

Once the 2G3G test completed, the keypad will display one of the following results :

- A level between 0/5 and 5/5.

- A GPRS Error code (please see Chapter 7 : 2G3G errors codes and contact your technical support).

If the screens shuts down, press any key to light it up except

OK or YES

,

ESC NO

or

CLR

.

The 2G3G level test can last several minutes. Do not interrupt the test or remove the SIM card during the test.

IMPORTANT : Videofied will require a 3/5 grade or better for reliable transmission of

Video alarms.

www.videofied.com

11

3. XT-iP Panel Programming

I N S T A L L M A N U A L

ETHERNET parameters configuration

IP

PARAMETERS ?

OK or YES

DHCP :

ENABLED

By setting the DHCP as

ENABLED, a new IP address will be assigned dynamically to the panel every time it connects to the network. Network parameters will not be asked.

OK or YES

DHCP :

DISABLED

If the router forces a static IP address for the panel, there will then be a need to define DHCP as DISABLED. You will then need to fill in the following network parameters fields : Panel IP, IP

Mask, Primary DNS, Gateway and Secondary DNS.

Warning: Verify that the IP address selected is available on the Network and accepted by the router.

OK or YES

During this test, the panel tries to connect to the local Ethernet Network. The result of this test can be:

• If the connection is successful: the local

IP of the panel will be displayed

(you can display other Ethernet parameters with the arrows ).

• ETHERNET OFF NO STATUS

: the

Ethernet module is switched off. Please verify that the Ethernet cable is connected and try again.

• CABLE OR NETWORK ABSENT

: the panel doesn’t detect Ethernet Cable or

Network.

PANEL IP

IP MASK

PRIMARY

DNS

GATEWAY

SECONDARY

DNS

ESC

NO

IP

PARAMETERS ?

ESC

NO

ETH. STATUS?

OK or YES

TEST IN PROGRESS

END = OK/YES

PANEL IP

XXX.XXX.XXX.XXX

ESC

NO

ETH. STATUS?

ESC

NO www.videofied.com

12

3. XT-iP Panel Programming

COMPATIBILITY

EN 50131 NORMS ?

OK or YES

ESC

NO

AREAS CONFIGURATION

OK or YES

AREA 1 NAME :

OK or YES

ARMING PROFILE :

STANDALONE

OK or YES

EXIT DELAY :

45 sec

For the selection

OK or YES

ENTRY DELAY :

15 sec

For the selection

Please go to page 15 if you chose

STANDALONE

I N S T A L L M A N U A L

For full compatibility with EN50131, press

OK or YES

.

Otherwise, press

ESC NO.

Press

ESC NO

to default the area names.

E

nter the name of the area 1 and

OK or YES

.

Repeat the procedure for areas 2,3 and 4.

For further details, please refer to chapter 4.3.

ARMING PROFILE :

FROM THE HOST

Please go to page 14 if you chose

FROM THE HOST

Your choice will depend on how you are arming the system :

Standalone

: Will make the XT-iP a completely independant system controlled by arming and disarming using Videofied peripheral devices(keyfobs, keypads, badge,readers).

From the host

: Will make the XT-iP panel a piggyback/xtender system that will only arm and disarm off the latching of 9-12V on the arming inputs 1 & 2.

Other values are available: 2 min, 1 min, 45 sec.

Other values are available: 2 minutes, 1 minutes,

45 seconds,30 seconds or 15 seconds.

www.videofied.com

13

3. XT-iP Panel Programming

XTENDER mode configuration

ARMING PROFILE :

FROM THE HOST

OK or YES

ARMING MODE

MODE :

SLOW

OK or YES

ENTRY DELAY

VALUE (0-255) :

(000) : _

OK or YES

TRANSMISSION DELAY

VALUE (0-600) :

(000) : _

OK or YES

ARMING CONFIRMATION

VALUE (0-240) :

(0) : _

MODE :

FAST

I N S T A L L M A N U A L

MODE SLOW

: : The panel will arm each device one at a time saving battery life. We recommend this mode .

MODE FAST

: The panel will arm all devices at the same time. This mode increases significantly the battery consumption.

OK or YES to choose the parameter

.

Enter the value for your Entry Delay up to 255 seconds and press

OK or YES.

Note : In From the Host mode, the entry/exit delay are dealt by the master system.

The transmission delay value sets the delay between the detection of an event and its transmission to the monitoring center.

Except when specifically required, please enter 0.

Enter the value you would like for the Transmission

Delay and press

OK or YES.

Arming Confirmation is the number of seconds the system will wait to arm after voltage is latched on the arming input. This feature can be used as an exit delay, we suggest you to enter the same value as your master system exit delay.

Enter the value you would like for the Arming

Confirmation and press

OK or YES.

For further information about the programmable inputs and outputs, please consult the following application notes available on our support website:

240-XT - APP NOTE - XTENDER CONFIGURATION MODE

www.videofied.com

14

3. XT-iP Panel Programming

RECORDING

DEVICES

PRESS PROGRAM

BUTTON OF DEVICE

ENTERING A NEW DEVICE ?

ESC

NO

BADGE ENTERED ?

OK or YES

ESC

NO

END OF

CONFIGURATION

RECORDING A

NEW BADGE ?

ESC

NO

OPERATION

COMPLETED ?

OK or YES

SYSTEM CHECK

IN PROGRESS

INSTALLATION SUCCESSFUL !

I N S T A L L M A N U A L

Each device has a unique programming button or a specific manipulation. Please refer to the Installation

Sheet for the device you would like to program.

Please check the radio level of each device on its final location. The result must be 8 out of 9 as a minimum (Please refer to the Radio Range section, page 8 for further details).

Each system can embrace a maximum of 25 devices,

programming keypad included.

Press

OK or YES

to enter a new device or

ESC NO

to move to the next step.

After initial programming has been completed, the system cannot be armed or disarmed until a user code or badge is entered (the installer code cannot arm or disarm the system).

Press

OK or YES

to register one or more badges.

ESC NO

if you’re not using any badges.

If you wish to use an user code, please skip this step and when initial programming is completed go to the BADGES/ACCESS CODES menu (please refer to chapter 4.4 for further details).

Badges and codes are limited to 19 for user (level 2 or 3) + 1 installer code.

Before completing programming make sure that all tampers are depressed by verifying that each device is closed and the indicator LEDs are off.

After initial programming has been completed, make use of the menu overview document (available on our technical support website), to see full programming options.

www.videofied.com

15

4. XT-iP features guide

I N S T A L L M A N U A L

4.1 Get to Access level 4

Tue 29/10 11:23

DISARMED LVL:1

ACCESS LEVEL

1

OK or YES

To unlock and get access to the installer level 4, you need to successively enter TWO codes

(in any order) :

• INSTALLER CODE (entered during intial programming).

• USER CODE (Level3): the user must authorize the installer to get access to the configuration of his panel.

ACCESS LEVEL

LEVEL : 1

ACCESS LEVEL

LEVEL : 4

OK or YES

BADGE OR CODE

OK or YES

4.2 How to Arm/Disarm the System

When in the standby mode, the system can be armed with the embedded or remote keypad , the remote keyfob and/or the embedded or remote badge reader.

Full arming with user code

Full arming with badge Special Arming 1 Special Arming 2

With remote keypad

Enter your user code and press

OK or YES

Present your badge on the keypad

( XMB model only)

Press / enter your user code and press

OK or YES

Press / enter your user code and press

OK or YES

With remote badge reader

BR250

With remote keyfob

N/A

N/A

Present your badge on the badge reader

N/A

N/A

Press

N/A

Press

www.videofied.com

16

4. XT-iP features guide

I N S T A L L M A N U A L

4.3 Arming and Siren Mode Configuration

Use the to go to menu :

CONFIGURATION

(LEVEL 4) -> SPECIAL ARMING MODES -> FULL ARM, SP1 or SP2 use direction arrows to select the arming mode you want to modify and

OK / YES

.

There are 3 different arming modes :

FULL ARM : Arming of all areas and all devices. Use a badge or a user code and press

OK

/ on the XMA/XMB keypad or the

YES

key on the CMA keypad.

SP1 : Partial Arming (1) is enabled by entering the user code and pressing on the XMA/XMB keypad, the key on the CMA keypad or on the remote keyfob RC.

SP1 : Partial Arming (2) is enabled by pressing the key on a XMA/XMB keypad, on a CMA keypad, or on the remote keyfob RC.

For each arming mode, it is possible to specify how each of the 4 areas will be armed and how the system will behave during an alarm.

Areas : 1 2 3 4

State A A A A

Each time you press the corresponding number, the system will toggle the arming state for the respective area.

OK / YES

.

after this configuration step. The system will then display what siren mode will be in effect for this special profile. Select the siren mode using the direction arrows then press

A

D

P

E

Armed

Disarmed

Perimeter

(by default : all opening contacts*)

External

(by default : all opening contacts with external access*)

Siren

Delay Beeps

Silent

Without Siren

Immediate triggering of all sirens

Entry/Exit delay beeps, then triggering of all sirens

No Sirens, No Beeps

Beeps on the keypad only

* You can set your devices as : External, Perimeter, ou External +Perimeter. Please go to the menu:

CONFIGURATION (LVL 4) -> AREAS AND DEVICES -> DEVICES -> DEVICES CONFIGURATION -> DEVICE TYPE

When in the ‘Arm From Host’ mode, the Videofied system will only arm and disarm when 9-12v is supplied and sustained.

When both arming inputs are supplied voltage at the same time the Videofied Keypad display will show ‘SYSTEM ARMED.

When only one arming input is supplied voltage the Videofied Keypad display will show ‘PART LVL #’

• Arming Input 1 will arm/disarm Areas 1 & 2 – Area 1 is delayed by default

• Arming Input 2 will arm/disarm Areas 3 & 4– Area 3 is delayed by default

www.videofied.com

17

4. XT-iP features guide

I N S T A L L M A N U A L

4.4 Manage badges and access codes

Access Level

Access Level

LVL 1

LVL 2

Definition & Rights

Standby Level

Restricted USER level,

where it is only possible to arm/disarm the system.

LVL 3

USER level,

where it is possible to arm/disarm the system, check the event log, test the devices.

Modifications of the settings are not possible at this level.

User Level 3 can create Level 2 or Level 3 access codes or badges.

LVL 4

INSTALLER level,

where it is possible to modify the setup of the panel.

To access Level 4, the approval of a Level 3 oe Level 2 user is required.

Installer Level 4 can creat the first Level 3 access code only.

Codes and badges created after the installer code will automatically set to Access Level 3.

How to return to the LVL1?

After 1 min of no use of the keypad and no tests running, the display returns to the standby display and LVL1.

When standby display, if the

ESC NO

key is held during 5s, the level is changed to LVL1.

www.videofied.com

18

4. XT-iP features guide

Enter a new end user Badge/Code

BADGES

ACCESS CODES

OK or YES

ENTER A

BADGE/CODE

OK or YES

BADGE OR CODE

Enter a 4-6 digit user code and

OK or YES or present a badge in front of the reader until you hear the registration beep.

CONFIRM THE

CODE

OK or YES

CODE NAME :

OK or YES

ACCESS 2

ENTRY COMPLETE

Reserved Codes

The XT-iP system can accept up to 19 (+1 installer code) Badges or

Access codes in any combination.

The table presents the reserved code possibilities that cannot be used.

A total of 186 codes are forbidden.

www.videofied.com

I N S T A L L M A N U A L

Delete an end user Badge/Code

ENTER A

BADGE/CODE

Press twice on the right arrow

DELETING

BADGES/CODES

OK or YES

Badges/codes list

Select badge/code then

OK or YES

DELETING CODE

ACCESS 5

OK or YES

CODE

DELETED

Reserved Codes

000000

From 9998 to 9999

From 99998 to 99999

From 999898 to 999999

From 314157 to 314159

All codes +1

All codes +2

All codes -1

All codes -2

19

4. XT-iP features guide

4.5 Delete the keypad or any other device

ACCESS LEVEL

4

CONFIGURATION

OK or YES

GENERAL

PARAMETERS

I N S T A L L M A N U A L www.videofied.com

AREAS AND

DEVICES

OK or YES

DEVICES

OK or YES

ADD A NEW

DEVICE

DEVICE

CONFIGURATION

OK or YES

Devices list to select the device and press

OK or YES

A1 : KEYPAD

KEYPAD 1

OK or YES

DELETE

OK or YES

< = = = = XX = = = = >

You can now remove the batteries from the device

20

4. XT-iP features guide

I N S T A L L M A N U A L

4.6 Read the event log

When user disarms the system, the keypad indicates the last event.

In case of the user needs to read the full log file, use the keypad to go in EVENT

LOG, press

OK or YES

on SELECT LAST

EVENTS and use arrow to list the events.

EVENT

LOG

OK or YES

SELECT LAST

EVENTS

OK or YES

15/10/13 11:29

MODIFIED PARAMET

15/10/13 11:10

SYSTEM DISARMED

Press

OK or YES

for more information about an event

4.7 Programmable inputs and outputs

The XT-iP control panel has 3 programmable inputs and 2 programmable outputs. Please note that we advise to connect the panels to a power supply when using programmable inputs. These functions allow the linking of Videofied® security systems to auxiliary equipment such as panic buttons, pepper spray, smoke generator, hard-wired door contact, light curtain, etc.

PROGRAMMABLE INPUT 1, PROGRAMMABLE INPUT 2 and PROGRAMMABLE INPUT 3 are triggered by voltage between 9V and 15V and an intensity between 1,5mA (@9V) and 3mA (@15V). If a dry contact is used to trigger the programmable inputs, the REF+output can be used to supply this dry contact.

PROGRAMMABLE OUTPUT 1 and PROGRAMMABLE OUTPUT 2 can be triggered either by a panel event, by a peripheral device or by an external event such as a programmable input or a arming input.

The XT-iP control panel also offer a mapping feature. Mapping option allows the input to generate a video-clip via a

MotionViewer when a programmable input is triggered and/or when an event occurs.

Prog. Out. COM

Prog. Output2

Prog. Output1

Ref GND

Prog. Input3

Prog. Input2

Prog. Input1

Ref+

Ref GND

Arming Input2

Arming Input1

Ref+

PWR AC2/DC-

PWR AC1/DC+

Prog. Out. COM

Prog. Output2

Prog. Output1

Ref GND

Prog. Input3

Prog. Input2

Prog. Input1

Ref+

Ref GND

Arming Input2

Arming Input1

Ref+

PWR AC2/DC-

PWR AC1/DC+

For further information about the programmable inputs and outputs, please consult the following application notes available on our support website:

240-XV-XT - PROG INPUTS - APP NOTE

240-XV-XT - PROG OUTPUTS - APP NOTE

www.videofied.com

21

4. XT-iP features guide

I N S T A L L M A N U A L

4.8 Golden rules

1

Area 1 is always delayed.When you register a keypad or a badge reader into an area, that area will automatically be delayed.

2

Never position a panel next to a high voltage electrical cabinet .

3

Press CLR to erase a typing mistake.

4

Never register the same device twice (delete from the system first).

5

Registration of up to 25 devices (including the keypad).

6

Respect indoor infrared devices installation height (2m10 to 2m30).

12 LCD screen goes dark after 30 seconds of inactivity, press an arrow or numeric key to light it up.

13 Use only batteries provided by RSI (panel and siren : Alkaline

batteries).

7

Outdoor cameras have to be installed at 2m60 to 3 meters

height

. Those devices needs to to protect an access and not a zone.

8

Do not fix the keypad at the beginning of the installation as it will need to be portable during programming.

10 key from the CMA keypad or hold a digit key (0 to 9) for

XMA/XMB.

11

14

15

To switch between UPPER and lower case, use the M/m

Internal components are fragile, be careful opening or closing the panel.

Infrared detectors should never be installed in stairs or close to stairs (false alarm risks).

A colon display [:] means that the parameter can be

changed.

9

Always clean

the lens of the cameras after the installation

(Use a clean, dry cloth, taking care not to exert pressure on the lens).

www.videofied.com

22

5. Ethernet parameters

I N S T A L L M A N U A L

To configure Ethernet parameters, using the direction arrows, go to the menu :

CONFIGURATION

Lvl. 4

OK or YES

GENERAL PARAMETERS

OK or YES

ETHERNET

To configure or modify Ethernet Parameters, go to:

• IP Parameters

:

If you wish to use the Ethernet transmission mode, two options are available:

1. DHCP Enable

: IP address is assigned by the DHCP service on the network. (Dynamic IP address). This is the default option.

2. DHCP Disable

: IP address must be defined in Ethernet parameters. IP address will NOT be automatically obtained from DHCP service on the network. Each connection from the panel to the network (alarms transmission), the XT-iP will have the same connection parameters. You must first connect to the router in order to get the network parameters and all available IP addresses. The following parameters must be filled in the IP PARAMETERS sub-menu: PANEL IP, IP

MASK, GATEWAY, PRIMARY DNS, SECONDARY DNS.

• Constant Ethernet

:

Three options are available:

1. “Auto” Mode

- We recommend this mode. If main powered, the panel will be connected constantly to the local

Network. In case of an alarm, the alarm will be sent in few seconds to the monitoring station. When the main power is cut, the Ethernet module will switch off after a delay (DELAY BEFORE OFF – 30 by default) in order to save battery life. In case of an alarm, the panel will at first connect to the local Network. It adds few seconds to the total process of sending an alarm.

You can set the delay in this menu :

CONFIGURATION

(LVL 4) -> GENERAL PARAMETERS -> ETHERNET -> CONSTANT ETH. -> DELAY BEFORE OFF

.

2. “ON” Mode

- The panel will be connected constantly to the local Network. This option will impact back-up battery life.

3. “OFF” Mode

- For each transmission of alarm and video, the panel will connect to the local Network.

• PING reply, Time Out Server, Max Seg. Size:

• PING REPLY: Enables ping response.

• Time Out Server: In case of disconnection to the local Network, the panel will try after that time to re-connect.

• Max Seg. Size: Maximum size of packet sent.

www.videofied.com

23

6. Transmitted Events List

I N S T A L L M A N U A L

The XT-iP panel can be configured to enable or disable the transmission of events like alarms or defaults.

The installer can modify the default sending settings for those events, although it will end the EN50131 standard compliance.

These are the default transmitted events :

DEVICE (intrusions)

ALERT (Panic Buttons)

PANEL LOW BATT.

TAMPER

DEVICE LOW BATT.

PERIODIC TEST

DURESS CODE

FIRE

MEDICAL ASSIST.

ETHERNET CABLE

AC POWER LOSS (AC Power supply)

The following events are not sent by default :

PANEL RESET

PHONELINE FAULT

RADIO JAMMING

SUPERVISION

5 WRONG CODES

ALARM CANCEL

ARM/DISARM (On/Off)

ZONE BYPASS (bypass function enabling/dsiabling)

SWINGER SHUTDOWN

There is 3 different transmission states :

ALARM

: event transmitted upon occurrence

ALARM/END :

event is transmitted on occurrence and on event restoral

NOT TRANSMITTED :

event is not transmitted, however it will appear on the keypad.

Example :

If the monitoring station system is set to receive arms and disarms, the ARM / DISARM parameter must be changed from NOT TRANSMITTED to ALARM / END.

How to modify the transmission state

At initial programming, right after the PERIODIC TEST CALL step:

CODE/STATE

MODIFICATION

Press

OK or YES

to access EVENT TRANS. MODIFICATION menu.

After initial programming, using a remote keypad :

Use the arrows to access :

CONFIGURATION

(level 4) > CONFIGURATION MONITOR. STATION > MONITORING PARAMETERS > EVENT TRANS. MODIFICATION

Then use the arrows to determine the event to modify. Press

OK or YES

to edit.

www.videofied.com

24

7. 2G3G Error Codes

I N S T A L L M A N U A L

IMPORTANT

: The PIN of the SIM card has to be deactivated or 00000.

The following is a list of error codes that can appear after the 2G3G test.

2G3G LEVEL :

ERROR XXX

In case of 2G3G (GPRS) errors during initial programming, we strongly suggest to continue with the installation and perform the 2G3G (GPRS) level test again once achieved.

Codes

03 ou 04 LP

003

010

Errors

No network coverage or no SIM card inserted

SIM card not detected/not inserted

SIM not inserted

011

PIN code necessary

-> PIN code must be deactivated

012

013

014

015

PUK code necessary, SIM card blocked

Default SIM card

SIM card busy

Error on SIM

030, 043,

057, 102,

132, ...

• No network coverage

• Typographical error in the APN Code, username, password

• SIM card not activated

This error checklist is provided for information purposes only.

This is not a comprehensive list

, but it is representative of most cases. Some events or codes are subject to change by SIM card operators.

However, the GPRS level test errors results in the majority of cases have the following causes :

• SIM Card activation Delay:

Some operators require an additional delay up to 48 hours to activate automatic data transmission. Please check with your operator prior to installation.

• APN CODE, USERNAME and PASSWORD :

The GPRS (2G3G) settings are supplied by the operator. Please make sure you have entered the code exactly as indicated by your local SIM card operator.

Note: When entering your SIM card settings, both APN codes, username and password fields are case sensitive! (It makes a difference between UPPER and lower case letters).

To switch between UPPER and lower case, use the M/m key from

CMA keypad or hold a digit key (0-9) for XMA/XMB.

• Insufficient GPRS Network:

When the panel is unable to find any signal, proceed to GPRS level test in another location on site. You can also find the network state or condition of use by directly contacting your local operator.

www.videofied.com

25

8. Technical specifications and security notes

I N S T A L L M A N U A L

Tamper detection

Tamper

Notes de sécurité / (EN) Security notes / (DE) Hinweise zur Sicherheit

Français

• Retirez les piles avant toute opération de maintenance !

• Attention ! Il y a un risque d'explosion si l'une des piles

utilisées est remplacée par une pile de type incorrect !

• Respectez la polarité lors de la mise en place des piles !

• Ne jetez pas les piles usagées ! Ramenez-les à votre

installateur ou à un point de collecte spécialisé.

English

• Remove battery before any maintenance !

• WARNING, there is a risk of explosion if a battery is

replaced by an incorrect type!

• Observe polarity when setting up the batteries!

• Do not throw used batteries! Bring them to your

installer or a collection point.

Deutsch

• Batterien vor jeglichen Wartungsarbeiten entfernen!

• Vorsicht, es besteht Explosionsgefahr, wenn eine

Batterie durch eine Batterie falschen Typs ersetzt wird!

• Achten Sie beim Einsetzen der Batterien auf die Polung!

• Entsorgen Sie Batterien nicht im normalen

zu den öffentlichen Sammelstellen.

Haushaltsmüll! Bringen Sie Ihre verbrauchten Batterien

Electrical data

Power requirements (option 1)

Power supply Type B

Low voltage limit

Backup 6V with 4

Low battery limit

Battery life (average)

Average current consumption (over 1h)

Max current

9-12VDC / 1,2A

5,15V x 1,5 V D Alkaline batteries /LR20

4,2V

1 year

450µA

1,2A

GPRS Transmission

Communicator

Communicator type

Security Protocol

GPRS/Ethernet

Frontel

IP Stack TCP/IP

Video transmission

By Frontel protocol to central monitoring station

GPRS antenna

External GPRS antenna

Integrated

Yes via MMCX connector

RF S

2

View

®

Technology

Radio type

Operating frequency

Transmission security

Radio jam detection

Bidirectional RF

868/915/920 MHz

AES algorithm encryption

Yes

Supervision Yes

Antenna Integrated

External radio antenna Yes via MMCX connector

Wall and cover tamper detection

Video

Video format

Video size

Video length

MPEG

Depending on camera type

10 seconds

Miscellaneous

Programming

Remote Devices per system

Access Badges/codes

Special arming mode

Number of Areas

History / Event log

With remote Keypad

25 maximum

20 maximum

4

4

4,000 events stored on flash memory

Programmable wired input

Number 3

«Dry» contact Yes

Input voltage 12 VDC (15VDC max)

Programmable wired outputs

Number 2

Max switching voltage 60VDC /30VAC

Max switching current 4A

Max switching power 120 VA

Box

Physical and Environmental Datas

Operating temperature

Maximum relative humidity

-10°/+40°C

75%, non-condensing

Material ABS—ULV0

Dimensions 225 mm x 180 mm x 55mm (LxWxD)

Weight 520gr (without batteries) / 1600gr (with batteries)

Installation/Mounting

Control Panel/Base

Two screws secures control panel cover to base; Three screws secure control panel base to the wall

Approvals

EN50131-1

: 2007 - Grade 2 – Class II

EN50131-3

:2009 - Grade 2

EN50131-4

:2009 Grade 2

EN50131-5-3

:2005 - Grade 2

&

&

EN50131-6

:2008 Grade 2 –Type B &

NF C 48-212

:2004

NF EN50130-4

:1995; A1:1998; A2:2003

NF EN50130-5

: 1998 Class II

RTC 50131-3

:2009

RTC 50131-4

:2009

RTC 50131-6

:2008

EMEA SALES

23, avenue du Général Leclerc

92340 BOURG-LA-REINE

FRANCE

E-Mail : [email protected]

North American Headquarters

1375 Willow Lake Blvd, Suite 103

Vadnais Heights, MN 55110

USA

E-Mail : [email protected]

www.videofied.com

26

advertisement

Key Features

  • Two-way radio frequency transmissions with all peripherals
  • Integrated antennas for a wireless system
  • Jamming detection feature
  • Supervision feature for signal reliability
  • Programmable inputs and outputs
  • Ethernet connectivity for remote access and control
  • Support for external antennas for increased radio and GPRS performance

Related manuals

Frequently Answers and Questions

What is Videofied XT-iP 730?
It's a fully wireless alarm system intended mainly for residential and commercial markets.
Is it possible to increase the Radio and/or GPRS performances of the XT-iP alarm system?
Yes, you can connect externally wired antennas.
What technology does XT-iP alarm panel use?
It uses the S2View® patented technology, an interactive wireless and AES encrypted technology ensuring signal integrity and optimal security.
Does it have programmable inputs and outputs?
Yes, XT-iP panel has three wired programmable inputs and two wired programmable outputs..
How many peripherals can XT-iP panel support?
XT-iP panel can support up to 25 wireless peripherals and 3 programmable inputs.
What is the XTENDER mode?
XTENDER mode allows the XT-iP panel to be used as a standard standalone alarm system.
How many digits can be used for the Installer Code?
4 to 6 digits.
Is there a backdoor or Default code to the system?
No