Schlage F-Series Ethernet Upgrade Installation instructions
Schlage F offers advanced features for enhanced security and convenience. With its Ethernet connectivity, you can seamlessly integrate it into your network, enabling remote access and monitoring. The device's robust construction and weather resistance make it suitable for both indoor and outdoor use. Additionally, its intuitive user interface and customizable settings allow for easy configuration and operation. Whether for securing your home, office, or other premises, Schlage F provides a reliable and versatile security solution.
广告
广告
FRONT
17.000
BEGINNING SHEET
11.000
FRONT
8.500
11.000
FOLDED SHEET
Additional Notes:
2 sheets, 1 fold, side stitched
E F
Revision History
G H
Material
White Paper
Notes
1. printed two sides
2. printed black
3. tolerance: ± .13
4. see sheet 2 for artwork
5. printed in country may vary
6. drawings not to scale
J K
20156 062621
Revision Description:
K > Allegion Rebranding
Edited By Approved By EC Number Release Date
R. Byun
Title
F-Series Ethernet Upgrade Instruction
Creation Date
08-29-11
Created By
J. Ellis
Number
M. Roberts
70200-0014
Activity
3899 Hancock Expwy
Security, CO 80911
062621 05-14-2015
Revision
K
Allegion
Copyright © 2015
F Series Ethernet Upgrade
Installation Instructions
70200-0014
Ethernet Requirements
• A TCP/IP network
• CAT 5 cable or better
• 10baseT
• Static IP address, gateway and subnet addresses (if needed)
• Port 3001 must be opened
Power Up
A reader with an Ethernet adapter installed and the network cable plugged in will automatically detect the presence of the Ethernet adapter upon power up. If the network cable is not plugged in prior to power being applied, the Ethernet adapter will not see the network and the reader will ask if the cable is plugged in. Plug in the network cable and power cycle the reader. When the reader boots up and detects the network, the LCD will display an IP address and then proceed to either the “Enter ID” or “Ready” prompt.
Address Requirements
The EN-100/200 does not support DHCP; therefore a static IP address is required and must be programmed into the reader before the adapter will communicate with the network.
Obtain all addresses that are required for the network from the system administrator of the site. If there is no need for a gateway address, set it to all zeros (i.e. 000.000.000.000). If the reader is required to communicate over a WAN, the subnet mask needs to be converted to a host bit number. If a subnet mask is not needed, set the host bit to 0. Have the system administrator set Port 3001 to allow access on all switches and routers between the EN-100/200 and host program.
To configure the Ethernet adapter, follow these steps:
1. The reader’s IP address resides in the SET SERIAL command of the SETUP menu, which is by default in the menu 2 of the reader.
2. Press # when the LCD display shows.
SET SERIAL
* NO YES #
3. Enter the 12 digit IP address using leading zeros and press #.
4. Enter the 12 digit gateway using leading zeros or enter all zeros if no gateway is required then press #.
5. Enter the host bits if the reader will be communicating over a WAN, or leave the host bits set to 0 if not needed and then press #.
6. Press CLEAR twice to exit menu.
Subnet to Host Bits Conversions
The readers will only accept a host bit, so the subnet mask needs to be converted. The only legal subnet masks and host bits are listed below:
SUBNET MASK
255.255.255.255
255.255.255.254
255.255.255.252
255.255.255.248
255.255.255.240
255.255.255.224
255.255.255.192
255.255.255.128
255.255.255.0
255.255.254.0
255.255.252.0
255.255.248.0
255.255.240.0
255.255.224.0
255.255.192.0
255.255.128.0
255.255.0.0
255.254.0.0
255.252.0.0
255.248.0.0
255.240.0.0
255.224.0.0
255.192.0.0
255.128.0.0
255.0.0.0
HOST BITS
0
14
15
16
17
18
19
10
11
12
13
20
21
22
23
24
3
4
5
6
1
2
7
8
9
2
Installing the EN-200 Ethernet Adapter
Î The EN-100 Ethernet adapter is not field installable. Call the factory for installation.
CAUTION:
This procedure requires a cold boot. Back up all data with the host program before proceeding.
CAUTION:
If the reader is equipped with an optional battery backup, remove the J7 jumper before proceeding. Failure to do so could lead to risk of shock and/or main board damage, if the ground strap were to touch the main board. See figure 9.
CAUTION:
Before removing the back plate of reader, wear a grounding wrist strap to help aid in protecting the circuit board from any ESD damage that might occur from improper handling.
1. Unlock the reader and rotate.
2. Disconnect the power supply from the board.
3. Remove and tag all external connections to make correct re-attachment.
4. Remove HandReader from wall by sliding it to the right, away from the wall mount. See figure 1 below.
Wall Mount
Reader
Figure 1
3
5. Set the reader on a firm surface such as a table. Remove the four screws that secure the back plate to the reader. Remove the grounding screw and/or ground lug (if present). See figure 2 below.
4
J9
1
Back
Plate
Screws
Ground Lug, if present
See Caution
Above
Main Circuit
Board
Grounding
Screw
Figure 2
6. Carefully remove the back plate.
7. Locate the cable on the left side of the reader that runs from the top panel circuit board to the main circuit board. Disconnect this cable from J9 on the main circuit board. See “1” on figure 3. To remove the J9 connector from the main circuit board, depress the retaining clip on the connector and pull upwards. Take care to pull on the connector and to not pull on the cable. See figure 4 below.
Press to Release
Main Circuit Board
Figure 3 Figure 4
8. Carefully slide the main circuit board out until the ribbon cable between the camera assembly and J2 on the main circuit board is accessible. First, disconnect the J5 connector from the main board. To remove, depress the retaining clip on the J5 connector and pull upwards. See “2” on figure 5 below. Next, remove the ribbon cable from J2 by gently pulling up on this cable, being careful not to pull down as damage may occur to the camera assembly. See “3” on figure 5 below.
Camera
Assembly
3 2
Grasp here to lift
Grasp here to lift
J2 J5
Figure 5
9. Carefully remove the main circuit board by sliding it free from the chassis.
10. Align the Ethernet adapter and carefully press the Ethernet card into place. Install the washers and nuts to secure the adapter. See figure 6 below.
CAUTION:
Torque the 4-40 nuts to 4.5 – 5.5 in. lbs. (.51 - .62 Nm). Excessive torque may damage the circuit boards. After installing the Ethernet card, inspect for warped Ethernet or main PCBs.
Align male header so that there are two (2) empty sockets on each side when inserted into J10
J2
J3
J10
J6
J12
TS1 TS2
J5
TS3
J9
J4
!
CAUTION: Do not over torque the nuts. See step 10 for limits.
Figure 6
5
11. Carefully slide the main circuit board back into the chassis using the guides to align the board correctly. Leave the main circuit board out about 1”.
6
Circuit Board Guides
Figure 7
12. Attach the camera cable to J2 on the main circuit board. Take care to align the connector to the pins on the main circuit board and do not twist the cable, as this will damage the camera.
13. Plug in the J5 connector.
14. Locate the cable that runs from the top panel circuit board to the main circuit board. Connect this cable to J9 on the main circuit board.
See figure 8 for cable routing.
J4
Battery
(if installed)
J9
Main Circuit Board
Figure 8
15. Slide the main circuit board in the rest of the way.
16. Replace the back plate. Attach the grounding screw to the main circuit board using the lower right hole on the back plate. If a ground lug is present, do not allow it to come into contact with J7. Secure the back plate with the four screws removed in step 5.
17. Line up the slots at the bottom of the reader’s back with the four hinge pins at the bottom of the wall mount. Slide the reader to the left so the pins go in the slots. This fastens the reader to the wall and wall mount and forms a hinge.
18. Reconnect all external connections removed in step 3.
19. Hold down reset button and apply power. Once the reader has booted up, release the reset button.
20. Press “9” on the keypad to complete the reset when prompted.
21. Reconnect the J7 jumper (if applicable).
J7
Out
J7
In
Figure 9
22. Secure the unit to wall mount with key. Upgrade is completed.
7
What do the LEDs on the Ethernet adapter mean?
1. Steady red or yellow LED:
• This means the Ethernet adapter has finished booting up but has not tried to detect a network cable plugged in.
2. Red or yellow flashing:
• This means the Ethernet cable is not plugged in or no network is detected.
3. Red or yellow and green LEDs are both flashing:
• This means the Ethernet cable has been detected but IP address entered at the reader has not been sent to the Ethernet adapter yet. This status is normally not seen as this process happens quickly.
4. Steady green:
• This means communication with the network has been established but the host program has not contacted the Ethernet adapter yet.
5. Green flashing:
• This means everything is ready and messaging can occur when initiated by the host program.
8
Customer Service
1-877-671-7011 www.allegion.com
© Allegion 2015
Printed in U.S.A.
70200-0014 Rev. 05/15-k