Autoranging CombiScope Instrument I PM3370B-PM3380B-PM3390B PM3384B-PM3394B Reference Manual 4/1-Dec-2000 ® II IMPORTANT In correspondence concerning this instrument please give the model number and serial number as located on the type plate on the rear of the instrument. NOTE: The design of this instrument is subject to continuous development and improvement. Consequently, this instrument may incorporate minor changes in detail from the information provided in this manual. Fluke Corporation P.O. Box 9090 Everett WA 98206-9090, USA Fluke Industrial B.V. P.O. Box 680 7600 AR Almelo The Netherlands Copyright 1996, 1998 Fluke Corporation All rights reserved. No part of this manual may be reproduced by any means or in any form without written permission of the copyright owner. Printed in the Netherlands III Thank you for purchasing this FLUKE oscilloscope. It has been designed and manufactured to the highest quality standards to give you many years of trouble free and accurate measurements The powerful measuring functions listed below have been combined with an easy and logical operation to let you use the full power of this instrument each and every day. If you have any comments on how this product could be improved, please contact your local FLUKE organization. FLUKE addresses are listed in the back of this REFERENCE MANUAL. There is a USERS GUIDE available containing: - OPERATOR’S SAFETY INSTALLATION INSTRUCTIONS OPERATING INSTRUCTIONS HOW TO USE THE INSTRUMENT FUNCTION REFERENCE IV MAIN FEATURES There are five models in this family of Fluke oscilloscopes. Each of these models is a combination of an analog real-time oscilloscope and a fully featured digital storage oscilloscope. By pressing a single push button, you can switch the instrument from the analog mode to the digital mode and back. This allows each of the units to be used in an optimum operating mode for all kinds of signal conditions. Complex data streams, modulated waveforms, and video signals can often best be seen in the analog mode of operation. The digital mode of operation is more suited for single events, signals with low repetition frequencies, and when automatic measurements need to be performed. In this family there is a choice of five models. Two models have a bandwidth of 200 MHz, two have a bandwidth of 100 MHz and one has a bandwidth of 60 MHz. There is a choice of two models with four fully featured channels and three models with 2 channels plus external trigger input, all shown in the following table: Type Number Bandwidth Sample rate Number of Channels Input Impedance PM3370B 60 MHz 200 MS/s 2 1 MΩ PM3380B 100 MHz 200 MS/s 2 1 MΩ PM3384B 100 MHz 200 MS/s 4 1 MΩ PM3390B 200 MHz 200 MS/s 2 1 MΩ/50Ω PM3394B 200 MHz 200 MS/s 4 1 MΩ/50Ω In the same instrument family, there are two 200-MHz and two 100-MHz analog oscilloscopes that have specifications similar to the above-mentioned analog/digital combination oscilloscopes operating in analog mode. All analog/digital combination oscilloscopes listed above have the following features: - 32K sample acquisition memory in 4 channel versions. 8K sample acquisition memory, expandable to 32K in 2 channel versions. Up to 40 waveforms stored in memory or 204 waveforms with (optional) memory extension. Autoset function for an instant optimized signal display at the touch of a button. Auto-ranging attenuators. Auto-ranging timebase. Real time clock. V - Cursor measurements with 1% accuracies. Extensive set of fully automated voltmeter and time measurement functions. Probe operated ’Touch Hold and Measure’ function freezes the display and instantly displays the signal frequency, amplitude and dc voltage level. Peak detection for the capture of glitches as narrow as 5 ns. Pattern, State and Glitch triggering (2 ns, only in the 4 channel models). Event delay and pretriggering and posttriggering. TV triggering including HDTV and TV line selection. Serial interface for printing and plotting. Averaging to reduce signal noise and to increase the vertical resolution from 8 to 16 bits. Advanced mathematics, including digital low-pass filtering. A Math+ option adds integration, differentiation, histogramming, and (as part of a option) FFT. Sine interpolation and magnification which enables true to life four channel single shot acquisitions with a timebase up to 625 ns/div (32x magnified) A delayed timebase with full trigger features. An EIA-232-D interface (standard) and an GPIB/IEEE-488 interface (optional). Autocal for automatic fine tuning of all circuitry to achieve maximum accuracy under all user conditions. Closed case calibration for efficient maintenance of traceable calibration at minimum cost. The following options are available: - - A MATH+ option with more automated measurement functions including envelope and measurement pass/fail testing. Also included in this option are Integration, Differentiation, Histogramming, and FFT. Memory extension offering 32K acquisition memory and the ability to store 204 traces (of 512 samples each) in memory. IEEE-488.2 interface using the new SCPI (Standard Commands for Programmable Instruments) industry standard for remote control of test and measurement equipment. VI CONTENTS CONTENTS 1 CHARACTERISTICS Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.1 VERTICAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.1 Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.2 Deflection Modes (Analog Only) . . . . . . . . . . . . . . . . . . . . 1.1.3 Bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.4 Attenuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.5 Input Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.6 Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.7 Dynamic Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.8 Position Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.9 Trace Separation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.10 Max. Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.11 Step Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.12 Signal Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1.13 Vertical Accuracies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1-3 1-3 1-4 1-4 1-5 1-5 1-6 1-6 1-6 1-6 1-7 1-7 1-8 1.2 TIMEBASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1.2.1 Timebase (modes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1.2.2 Timebase Settings (Analog Mode Only) . . . . . . . . . . . . . . 1-9 1.2.3 DTB Delay (Analog Mode Only) . . . . . . . . . . . . . . . . . . . . 1-10 1.2.4 Timebase Settings (Digital Mode Only) . . . . . . . . . . . . . . 1-10 1.2.5 Timebase Delay (Digital Mode Only) . . . . . . . . . . . . . . . . 1-11 1.2.6 DTB Delay (Digital Mode Only) . . . . . . . . . . . . . . . . . . . . 1-11 1.2.7 Analog Timebase Accuracies . . . . . . . . . . . . . . . . . . . . . . 1-12 1.2.8 Delaytime Accuracy (Analog Mode) . . . . . . . . . . . . . . . . . 1-12 1.2.9 DTB Jitter In Starts (Analog Mode) . . . . . . . . . . . . . . . . . 1-12 1.2.10 Timebase Accuraries (Digital Mode) . . . . . . . . . . . . . . . . 1-12 1.2.11 DTB Jitter In Starts (Digital Mode) . . . . . . . . . . . . . . . . . . 1-12 1.2.12 External Horizontal Deflection . . . . . . . . . . . . . . . . . . . . . 1-13 1.2.13 Horizontal Display Accuracy . . . . . . . . . . . . . . . . . . . . . . 1-13 1.3 TRIGGERING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.1 Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.2 Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.3 TV Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.4 Coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.5 Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.6 Slope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.7 Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3.8 Logic Triggering Timing (Digital Mode Only) . . . . . . . . . . 1.3.9 Trigger Accuracies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14 1-14 1-14 1-14 1-15 1-16 1-17 1-17 1-18 1-18 CONTENTS VII 1.4 EVENT COUNTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 1.5 HOLD-OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 1.6 PROCESSING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20 1.6.1 Preprocessing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20 1.6.2 Register Processing (Digital Mode) . . . . . . . . . . . . . . . . . 1-20 1.7 TRACE MEASUREMENTS (DIGITAL MODE) . . . . . . . . . . . . . . . 1-21 1.8 CURSORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22 1.8.1 Cursor Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22 1.8.2 Cursor Readouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23 1.8.3 Cursor Accuracies ( Analog Mode) . . . . . . . . . . . . . . . . . 1-23 1.8.4 Cursor Accuracies (Digital Mode) . . . . . . . . . . . . . . . . . . . 1-23 1.9 DIGITAL ACQUISITION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 1.9.1 Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 1.9.2 Sample Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 1.9.3 Multiplexed Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 1.9.4 Trace Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-25 1.9.5 Acquisition Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-26 1.9.6 Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-26 1.9.7 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-27 1.9.8 Register Manipulations . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-27 1.9.9 Digital Acquisition Accuracies . . . . . . . . . . . . . . . . . . . . . 1-28 1.10 FRONT PANEL MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-28 1.11 BLANKING OR Z-AXIS (ONLY FOR ANALOG TRACE) . . . . . . . 1-28 1.12 DISPLAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-29 1.12.1 CRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-29 1.12.2 Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-29 1.12.3 Vertical Display Manipulations (Digital Mode) . . . . . . . . . 1-30 1.12.4 Horizontal Display Manipulations (Digital Mode) . . . . . . . 1-30 1.13 EXTERNAL INTERFACES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31 1.13.1 Calibrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31 1.13.2 Standard external interface . . . . . . . . . . . . . . . . . . . . . . . 1-31 1.13.3 Optional external interfaces . . . . . . . . . . . . . . . . . . . . . . . 1-33 1.13.4 Printers and plotters support . . . . . . . . . . . . . . . . . . . . . . 1-33 1.13.5 Real Time Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33 VIII CONTENTS 1.14 AUTO SET & CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-34 1.14.1 Auto Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-34 1.14.2 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-34 1.15 POWER SUPPLY AND BATTERY BACKUP . . . . . . . . . . . . . . . . 1-34 1.15.1 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-34 1.15.2 Battery Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-35 1.16 MECHANICAL CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . 1-36 1.17 ENVIRONMENTAL CHARACTERISTICS . . . . . . . . . . . . . . . . . . . 1.17.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.17.2 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.17.3 EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-36 1-36 1-36 1-38 1.18 SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-41 1.19 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-41 1.20 OPTIONS & OPTIONAL VERSIONS . . . . . . . . . . . . . . . . . . . . . . 1.20.1 Options Line cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.20.2 Options digital versions . . . . . . . . . . . . . . . . . . . . . . . . . . 1.20.3 Options analog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.20.4 Specification optional outputs . . . . . . . . . . . . . . . . . . . . . 1.20.5 Specification External trigger option . . . . . . . . . . . . . . . . . 1.20.6 Specification IEEE-OPTION . . . . . . . . . . . . . . . . . . . . . . . 2 PRINCIPLE OF OPERATION 1-42 1-42 1-42 1-42 1-43 1-44 1-45 . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2.1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2.2 CONTROL SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2.3 VERTICAL DEFLECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2.4 HORIZONTAL DEFLECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 2.5 CRT DISPLAY SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2.6 POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2.7 DIGITIZER SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 CONTENTS IX 3 BRIEF CHECKING PROCEDURE . . . . . . . . . . . . . . . . . . . . . 3-1 3.1 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3.2 Preliminary settings of the controls . . . . . . . . . . . . . . . . . . . . . . . 3-1 3.3 Vertical section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 3.4 Horizontal section, MAIN TB and DELAYED TIME BASE. . . . . . 3-8 3.5 Horizontal section, X-deflection. . . . . . . . . . . . . . . . . . . . . . . . . . 3-11 3.6 Cursors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11 3.7 TEXT OFF key: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 4 PERFORMANCE TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4.1 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4.2 RECOMMENDED TEST EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . 4-2 4.3 TEST PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 4.3.1 Preliminary settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 4.3.2 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 4.3.3 Auto set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 4.3.4 Orthogonality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 4.3.5 Trace distortion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 4.3.6 Vertical deflection; deflection coefficients . . . . . . . . . . . . . . 4-9 4.3.7 Vertical deflection; variable gain control range . . . . . . . . . 4-11 4.3.8 Vertical deflection; input coupling . . . . . . . . . . . . . . . . . . . 4-11 4.3.9 Vertical cursor accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 4.3.10 Vertical deflection; high-frequency response . . . . . . . . . . 4-13 4.3.11 Vertical deflection; low-frequency response . . . . . . . . . . . 4-14 4.3.12 Vertical deflection; dynamic range at 15/25/50 MHz . . . . 4-15 4.3.13 Vertical deflection; dynamic range at 60/100/200 MHz . . 4-16 4.3.14 Vertical deflection; position range . . . . . . . . . . . . . . . . . . 4-16 4.3.15 Vertical deflection; crosstalk between channels at 60/100/200 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17 4.3.16 Vertical deflection; common mode rejection ratio at 1 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19 X CONTENTS 4.3.17 4.3.18 4.3.19 4.3.20 4.3.21 4.3.22 4.3.23 4.3.24 4.3.25 4.3.26 4.3.27 4.3.28 4.3.29 4.3.30 4.3.31 4.3.32 4.3.33 4.3.34 4.3.35 4.3.36 4.3.37 4.3.38 4.3.39 4.3.40 4.3.41 4.3.42 4.3.43 4.3.44 Vertical deflection; common mode rejection ratio at 50 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Vertical deflection; LF linearity . . . . . . . . . . . . . . . . . . . . . Vertical deflection; visual signal delay . . . . . . . . . . . . . . . Vertical deflection; base line instability . . . . . . . . . . . . . . . Delay difference between vertical channels . . . . . . . . . . . Horizontal deflection; display modes and trace separation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Horizontal deflection; X deflection . . . . . . . . . . . . . . . . . . Horizontal deflection; MAIN TB deflection coefficients . . . Horizontal deflection; VARiable mode accuracy MAIN TB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Time cursor accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . Horizontal deflection; DELAYED TIME BASE deflection coefficients . . . . . . . . . . . . . . . . . . . . . . . . . . . . Horizontal deflection; delay time multiplier . . . . . . . . . . . . Horizontal deflection; delayed timebase jitter . . . . . . . . . . Horizontal deflection; X deflection coefficient via CH1 . . . Horizontal deflection; X deflection coefficient via ’line’ . . . Horizontal deflection; high frequency response . . . . . . . . Maximum phase shift between horizontal and vertical deflection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MAIN TB triggering PM3390B/3394B; trigger sensitivity via CH1, CH2, CH3 and CH4 (EXT) . . . MAIN TB triggering PM3370B/3380B/3384B; trigger sensitivity via CH1, CH2, CH3 and CH4 (EXT). . . MAIN TB/DEL’D TB triggering; trigger sensitivity TVL-TVF . . . . . . . . . . . . . . . . . . . . . . . . DEL’D TB triggering PM3390B/94B; trigger sensitivity via CH1, CH2, CH3 and CH4 (EXT) . . . DEL’D TB triggering PM3370B/80B/84B; trigger sensitivity via CH1, CH2, CH3 and CH4 (EXT). . . Trigger sensitivity in logic mode PM3394B . . . . . . . . . . . Trigger sensitivity in logic mode PM3384B . . . . . . . . . . . Z-MOD sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Probe Adjust signal; frequency and output voltage . . . . . Auto range functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Testing the optional auxiliary outputs . . . . . . . . . . . . . . . . 4-20 4-20 4-22 4-23 4-24 4-26 4-26 4-28 4-30 4-31 4-31 4-33 4-34 4-35 4-36 4-36 4-37 4-38 4-40 4-41 4-42 4-44 4-46 4-48 4-49 4-50 4-51 4-52 CONTENTS 5 PREVENTIVE MAINTENANCE XI . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5.1 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5.2 REMOVING THE BEZEL AND THE CONTRAST FILTER . . . . . . . 5-1 5.3 CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5.4 RECALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5.5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 XII CONTENTS ® DECLARATION OF CONFORMITY for Autoranging CombiScope Instrument PM3370B, PM3380B, PM3390B PM3384B, PM3394B Manufacturer Fluke Industrial B.V. Lelyweg 1 7602 EA Almelo The Netherlands Statement of Conformity Based on test results using appropriate standards, the product is in conformity with Electromagnetic Compatibility Directive 89/336/EEC Low Voltage Directive 73/23/EEC Sample tests Standards used: EN61010-1 CAT II Pol 2 Safety Requirements for Electronic Measuring Apparatus EN 50081-1 (1992) Electromagnetic Compatibility. Generic Emission Standard: EN55022 and EN60555-2 EN 50082-1 (1992) Electromagnetic Compatibility. Generic Immunity Standard: IEC801 -2, -3, -4, -5 The tests have been performed in a typical configuration. This Conformity is indicated by the symbol , i.e. "Conformité européenne". CHARACTERISTICS SPECIFICATION 1 CHARACTERISTICS CHARACTERISTICS 1-1 ADDITIONAL INFORMATION A. Performance Characteristics - - Properties expressed in numerical values with tolerances, ranges, or limits stated, are guaranteed by the manufacturer. Properties expressed in numerical values without tolerances, ranges, or limits stated, represent the characteristics of an average instrument. This specification is valid if the temperature has not changed more than + or 5 °C since the last AUTO CAL, the probe is of the same type as delivered with the instrument, and if the average factor is 8. For definitions of terms, reference is made to IEC Publication 351-1, 359. B. Safety Characteristics This instrument is designed for indoor use only. It has been designed and tested for measurements on 150 V rms Category II, Pollution Degree 2 in accordance with the following standards EN61010-1 (1993)(IEC 1010-1), ANSI/ISA S82.011994, CAN/CSA-C22.2 No.1010.1-92, UL3111-1. Installation Category II refers to local level, which is applicable for appliances, and portable equipment. The apparatus has been supplied in a safe condition. This manual contains information and warnings which must be followed by the user to ensure safe operation and to keep the instrument in safe condition. The instrument has been designed for indoor use. It may occasionally be subjected to temperatures between +5 °C and 10 °C without degradation of its safety. C. General Characteristics - Overall dimensions: • Height (without feet) • Width (without handle) • Length (without handle and front cover) : 139 mm ( 5.5 in) : 341 mm (13.5 in) : 481 mm (19 in) 1-2 CHARACTERISTICS CHARACTERISTICS Figure 1.1 Weight SPECIFICATION ADDITIONAL INFORMATION Dimensions 9.5 kg (19.7 lb) Operating positions: a) Horizontally on bottom feet b) Vertically on rear feet c) On the carrying handle in three sloping positions Note: All items that refer specifically to only one mode (analog or digital) are identified in the leftmost column with an ’A’ or a ’D’. CHARACTERISTICS CHARACTERISTICS 1.1 VERTICAL 1-3 SPECIFICATION ADDITIONAL INFORMATION CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION CHANNELS CH1; CH2; CH3; CH4 Form a channel set Form a channel set See Note 1 1.1.1 Channels Note 1: CH1 and CH2 for PM3370B, PM3380B and PM3390B. 1.1.2 Deflection Modes (Analog Only) MODES CH1, CH2, CH3, CH4 CH1 + CH2 CH3 + CH4 Automode: Auto attenuator See Note 1 CH2 and CH4 can be inverted to allow -CH2 or -CH4 CH2 can be inverted to allow CH1 - CH2 CH4 can be inverted to allow CH3 - CH4 CH1, CH2 CH3, CH4 All models PM3384B/94B CH1, CH2 CH3, CH4 See Note 2 All models PM3384B/94B Windows ON Alternate Chopped Chopped mode: Chopped freq. 1 MHz Note 1: CH1 and CH2 for PM3370B, PM3380B and PM3390B. Note 2: If more than one channel ON. 1-4 CHARACTERISTICS CHARACTERISTICS 1.1.3 SPECIFICATION ADDITIONAL INFORMATION Bandwidth FREQUENCY RESPONSE Lower transition point of bandwidth input coupling in AC pos <10 Hz At BNC PM3394B/90B Upper transition point of bandwidth (Ambient 5 to 40 °C) >200 MHz (Ambient 0 to 50 °C) >175 MHz See Note 1 See Note 1 PM3384B/80B Upper transition point of bandwidth (Ambient 5 to 40 °C) >100 MHz (Ambient 0 to 50 °C) >90 MHz With external 50Ω With external 50Ω PM3370B Upper transition point of bandwidth (Ambient 5 to 40 °C) >60 MHz (Ambient 0 to 50 °C) >55 MHz With external 50Ω With external 50Ω BANDWIDTH LIMITER Upper transition point of bandwidth 20 MHz Note 1: PM3394B CH1 through CH4 in 50Ω position at BNC. PM3390B CH1 and CH2 in 50Ω position at BNC. 1.1.4 Attenuator PM3394B/PM3384B CH1 to CH4 steps 2 mV/div to 5V/div PM3390B/PM3380B/PM3370B CH1 and CH2 steps 2 mV/div to 5V/div EXT TRIG steps 0.1V/div and 1V/div In 1-2-5 sequence In 1-2-5 sequence CHARACTERISTICS 1-5 CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION Variable gain mode 2 mV/div to 12.5V/div Continuously variable Auto Attenuator 2<div<6.4 1-2-5 steps precision (min. 50 mV/div) Auto Attenuator (Windows ON) 1<div<3.2 1-2-5 steps precision (min. 50 mV/div) 1.1.5 Input Characteristics INPUT CONNECTOR INPUT IMPEDANCE (in 1 MΩ pos.) R parallel-value - tolerance C parallel-value - tolerance BNC Measured at freq. <1MHz 1 MΩ ±1 % 25 pF ±2 pF INPUT INPEDANCE (in 50Ω pos.) R parallel value - tolerance VSWR (typical) See Note 1 PM3390B on CH1 and CH2 PM3394B all channels 50Ω ±1 % 1.5:1 See Note 2 Note 1: BNC with Probe Readout pin which causes the instrument to change V/div indication, input impedance, and attenuator setting according to the probe (when equiped with a probe indicator). Note 2: Measured up to 200 MHz input frequency; in dc and ac coupling of input. 1.1.6 Coupling COUPLING dc, ac, ground See Note 1 Note 1: In GND position: channel disconnected from input, and connected to ground, BNC open (when not in 50Ω position). The GND coupling is available for all channels except EXTTRIG. 1-6 CHARACTERISTICS CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION PM3390B/PM3394B Up to 50 MHz Up to 200 MHz ±12 div ±4 div Symmetrical Symmetrical PM3380B/PM3384B Up to 25 MHz Up to 100 MHz ±12 div ±4 div Symmetrical Symmetrical PM3370B Up to 15 MHz Up to 60 MHz ±12 div ±4 div Symmetrical Symmetrical + or - ≥ 8 div Symmetrical + or - ≥ 4 div MTB and DTB MTB fixed, DTB shifts 1.1.7 1.1.8 Dynamic Range Position Range POSITION RANGE 1.1.9 Trace Separation TRACE SEPARATION Min. range 1.1.10 Max. Input Voltage MAX. INPUT VOLTAGE See Note 1 In high Z position According to EN61010-1 Cat II Pol 2. Max. input voltage 150 V rms See Note 2. In 50Ω position dc ± 5V ac rms 5V See Note 3 ac peak ± 50V See Note 3 Note 1: The instrument should be properly grounded through the protective ground conductor of the power cord. Note 2: Up to 20 KHz; >20 kHz see figure 1.1 Note 3: Maximum of 50 mJ during any 100 ms interval. CHARACTERISTICS CHARACTERISTICS Figure 1.1 1.1.11 1-7 SPECIFICATION ADDITIONAL INFORMATION Max. input voltage versus frequency Step Response 5 Divisions Pulse In 50Ω Input Impedance STEP RESPONSE See Note 1 Note 1: Calculated from the formula: Rise time = 0.35 / Bandwidth and is measured over the central 5 divisions (vertical) 1.1.12 Signal Delay A: VISUAL SIGNAL DELAY 15 ns 13 ns PM3390B94B PM3370B/80B/84B DELAY BETWEEN CHANNELS CH1 and CH2 <250 ps CH1.... CH4 <250 ps PM3370B/80B/90B PM3384B/94B 1-8 CHARACTERISTICS CHARACTERISTICS 1.1.13 SPECIFICATION ADDITIONAL INFORMATION ±1.3 % Over central 6 divisions See Note 1 Vertical Accuracies ACCURACY deflection factor A: Gain error (dc) D: Additional gain error (dc) ±0.7% Gain error TrigView ±3 % A: Nonlinearity ≤2 % See Note 2 D: Digital non linearity ≤4.5 % See Note 2 0.2 div or 1 mV Whichever is greater (after autocal) MAX. BASELINE INSTABILITY Jump (all between steps, var, and N/I) Drift Temperature coefficient CHANNEL ISOLATION Of deselected channels at 10 MHz Of deselected channels at upper transition point Between selected channels CMRR at 2 MHz at 50 MHz 0.1 div/h 0.03 div/K 100:1 See Note 3 50:1 50:1 See Note 4 See Note 5 See Note 6 100:1 25:1 Note 1: Add 1.5% for variable gain mode. Note 2: 2 division center screen signal with a frequency of 50 kHz, shifted within central 6 divisions. Note 3: At 10 MHz; input to deselected channel equivalent to 8 divisions or less. Note 4: Channels with equal V/div; input to deselected channels equivalent to 6 divisions. Note 5: Channels with equal V/division settings; input to either channel 6 div. PM3390B/94B; max. input amplitude 3Vpp Note 6: Between any two input channels at same attenuator setting; VAR of V/div setting adjusted for best CMRR; measured with max. 8 div. CHARACTERISTICS CHARACTERISTICS 1-9 SPECIFICATION ADDITIONAL INFORMATION MTB only MTB and DTB DTB only MTB= Main Timebase Alternating TB-mode DTB = Delayed Timebase 1.2 TIMEBASE 1.2.1 Timebase (modes) TIMEBASE MODES Variable TB Auto TB MTB trigger modes AUTO TRIGGERED SINGLE SHOT SINGLE SCAN Free run after 100 ms DTB trigger modes DTB starts DTB triggered Starts after delay time Starts on first trigger after delay time 1.2.2 Timebase Settings (Analog Mode Only) MTB PM3390B/PM3394B Settings Variable Time/div range 0.5s/div to 20 ns/div 1.25s/div to 20 ns/div MTB PM3370B/PM3380B/PM3384B Settings 0.5s/div to 50 ns/div Variable Time/div range 1.25s/div to 50 ns/div DTB PM3390B/PM3394B Settings See Note 1 MTB continuously variable See Note 1 MTB continuously variable 0.5s/div to 20 ns/div See Note 1, See Note 3 DTB PM3370B/PM3380B/PM3384B Settings 0.5s/div to 50 ns/div See Note 1, See Note 3 TIMEBASE MAGNIFICATION See Note 2 10x 1 - 10 CHARACTERISTICS CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION Note 1: In a 1-2-5 sequence. By means of the timebase magnifier (x10) the range is extended to 2 ns/div (PM3390B/94B) or 5ns/div (PM3370B/80B/84B). Note 2: Expands the normal time/div by 10 times (MTB and DTB) Note 3: The DTB sweep speed is higher or equal to MTB time/div setting. 1.2.3 DTB Delay (Analog Mode Only) DELAY TIME 2 ns to 4.9s Position range 0.1 div to 9.9 div Resolution 1: 40000 1.2.4 Timebase Settings (Digital Mode Only) MTB Settings REAL TIME SAMPLING 200s/div to 250 ns/div See Note 1 and 4 ROLL 200s/div to 200 ms/div See Note 2 RANDOM SAMPLING PM3390B/94B PM3370B/80B/84B 200 ns/div to 2 ns/div 200 ns/div to 5 ns/div See Note 2 See Note 2 2 nsec ...1 µsec/div 1 µsec ... 500 µsec/div 500 µsec ... 200 sec/div 1-2-5 sequence steps 1 µsec step size equals analog step size Variable Timebase Auto Timebase Capture Range Dynamic Range DC up to full bandwidth 2 nsec ... 200 msec/div DTB Settings (STARTS/TRIGGERED) See Note 5 REAL TIME SAMPLING 0.5 ms/div to 250 ns/div or Whichever is greater 0.5 ms/div to 0.001x MTB setting See Note 1 and 3 RANDOM SAMPLING only for MTB 200 ns/div to 20 ns/div or Whichever is greater 200 µs/div to 2 ns/div 200 ns/div to 0.001x MTB setting See Note 2 and 3 CHARACTERISTICS CHARACTERISTICS 1 - 11 SPECIFICATION ADDITIONAL INFORMATION Note 1: In a 1-2-5 sequence and 250 ns. Note 2: In a 1-2-5 sequence. Note 3: The DTB sweep speed is higher or equal to MTB time/div. setting. Note 4: When DTBis on: 500 ms/div to .... Note 5: DTB is only possible with normal acquisition length. Triggered DTB is not possible in combination with tv, logic or event delay trigger mode. 1.2.5 Timebase Delay (Digital Mode Only) TIME DELAY TRIGGER POSITION Acquisition length normal Acquisition length max. PM3384B/94B PM3370B/80B/90B -10 to 0 div pretrigger -640 to 0 div -160 to 0 div pretrigger pretrigger, note 1 DELAY Resolution 0 to 1000 div steps of 0.02 div posttrigger sample distance EVENTS DELAY Range 1 to 16384 See event counter Note 1: When extended memory option is installed Time delay of trigger position at max. acquisition length is -640 to 0 div. pretrigger. 1.2.6 DTB Delay (Digital Mode Only) TRIGGERED DELAY TIME Position range Resolution 2 ns to 4.9 s 0.1 div to 9.9 div 1 : 40000 STARTS DELAY TIME Position range Resolution 0 to 10 div of MTB setting 0 div to 10 div 1 : 40000 1 - 12 CHARACTERISTICS CHARACTERISTICS 1.2.7 SPECIFICATION ADDITIONAL INFORMATION Analog Timebase Accuracies Unmagnified: Magnified: Up to 10 ns div In 5ns/div and 2ns/div ± (1.3% of reading +0.5% of central 8 div) ± (1.3% of reading +1.0% of central 8 div) ± (1.8% of reading +1.5% of central 8 div) See Note 1 See Note 2 See Note 1 See Note 1 Note 1: Add 1% of reading in variable mode. Note 2: Valid over central unmagnified 8 divisions. 1.2.8 Delaytime Accuracy (Analog Mode) MTB in 20 µs/div DTB in 2 µs/div PM3390B/94B PM3370B/80B/84B ± (0.8% of reading +0.3% of central 8 div + Tf) Tf = 4 ns Tf = 5 ns Note 1: add 1% of reading in variable mode. 1.2.9 DTB Jitter In Starts (Analog Mode) Jitter 1 part of 25000 1.2.10 Timebase Accuraries (Digital Mode) MTB, DTB Real Time Mode ±0.010% Equivalent Time Mode ±0.5% 1.2.11 Jitter DTB Jitter In Starts (Digital Mode) 120 ps See Note 1 CHARACTERISTICS CHARACTERISTICS 1.2.12 1 - 13 SPECIFICATION ADDITIONAL INFORMATION External Horizontal Deflection This paragraph is valid only for the analog mode. In the digital mode X versus Y is defined as a display mode. DEFLECTION SOURCES PM3384B/94B PM3370B/80B/90B LINE DEFLECTION Deflection amplitude CHANNEL DEFLECTION Error limit Linearity error limit Dynamic range up to 100 kHz up to 2 MHz Line and CH1 to CH4 Line, CH1, CH2, EXT TRIG 6 ±1.7 div ±5% ±2% Between 49 and 61 Hz at 220 volts Refer to VERTICAL Over central 6 divisions See Note 1 20 div 10 div POSITION RANGE ±5 div FREQUENCY RESPONSE Upper transition point 2 MHz MAX. PHASE DIFFERENCE Between horizontal and vertical 3° Up to 100 kHz Note 1: 2 div/50kHz center screen signal shifted within central 8 divisions. 1.2.13 Horizontal Display Accuracy Display Accuracy ±(0.8% of reading + 0.5% of central 8 divisions) 1 - 14 CHARACTERISTICS CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION 1.3 TRIGGERING 1.3.1 Source MTB trigger sources PM3384B/94B PM3370B/80B/90B CH1 to CH4, Line CH1, CH2, Line, EXT TRIG DTB trigger sources PM3384B/94B PM3370B/80B/90B CH1 to CH4 CH1, CH2 1.3.2 Modes MODES MTB triggering PM3384B/94B EDGE, TV, D:PATTERN, D:STATE, D:GLITCH PM3370B/80B/90B EDGE, TV, D:GLITCH MODES DTB triggering EDGE 1.3.3 Enter/exit pattern plus timed pattern. TV Systems TV systems TV HDTV See Note 1 See Note 1 TV Line 1 to n See Note 1 and 2 Note 1: Line selection possible in field1and field2. In digital mode, triggered DTB not possible in combination with TV line. Note 2: n is equal to maximum lines of TV system. CHARACTERISTICS CHARACTERISTICS 1.3.4 1 - 15 SPECIFICATION ADDITIONAL INFORMATION Coupling BANDWIDTH EDGE TRIGGER MTB Vertical coupling in DC Lower transition point of BW BW = Bandwidth Trigger coupling: DC AC LF-reject HF-reject dc 10 Hz 30 kHz dc Upper transition point of BW Trigger coupling: DC AC LF-reject HF-reject BW = Bandwidth ) )See sensitivity ) 30 kHz BANDWIDTH EDGE TRIGGER DTB Vertical coupling in DC Lower transition point of BW BW = bandwidth Trigger coupling: DC AC LF-reject HF-reject dc 10 Hz 30 kHz dc Upper transition point of BW Trigger coupling: DC AC LF-reject HF-reject BW = bandwidth ) )See sensitivity ) 30 kHz 1 - 16 CHARACTERISTICS CHARACTERISTICS 1.3.5 SPECIFICATION ADDITIONAL INFORMATION Sensitivity EDGE TRIGGER SENSITIVITY MTB and DTB of: PM3390B/94B dc to 100 MHz 0.6 div dc to 200 MHz 1.2 div dc to 300 MHz 2.0 div See Notes 1, 3, 4 See Note 2 PM3380B/84B dc to 50 MHz dc to 100 MHz dc to 200 MHz 0.6 div 1.2 div 2.0 div See Note 2 PM3370B dc to 30 MHz dc to 60 MHz dc to 150 MHz 0.6 div 1.2 div 2.0 div See Note 2 TV TRIGGER SENSITIVITY (ampl. of sync. pulse) 0.7 div See Note 1 TRIGGER SENSITIVITY D: PATTERN/STATE PM3394B Rectangle pulses t ≥ 10 ns t ≥ 2 ns 1.0 div 2.0 div See Note 5 PM3384B Rectangle pulses t ≥ 20 ns t ≥ 4 ns 1.0 div 2.0 div See Note 5 Note 1: All figures are valid for an ambient temperature range of 5 to 40 °C, add 20% for ambient 0 to 50 °C. Note 2: Measured with a 2 divisions center screen signal. Note 3: In noise trigger multiply stated value by 2. Note 4: In 2 ... 5 mV/div multiply stated value by 2. Note 5: Duty cycle 50%. CHARACTERISTICS CHARACTERISTICS 1 - 17 SPECIFICATION ADDITIONAL INFORMATION Slope selection edge + or - D:Dual slope Up to full vertical bandwith MTB and DTB See Note 1 See note 2 1.3.6 Slope Note 1: In TV-triggering positive/negative video. Note 2: Only in single shot, real time mode. 1.3.7 Level LEVEL CONTROL RANGE MTB EDGE Unless: In level p(eak)p(eak) TV Fixed D: PATTERN, STATE and GLITCH ±5 div LEVEL CONTROL RANGE DTB EDGE ≥±8 div ≥±8 div See Note 1 PM3370B/80B/90B: glitch mode only Note 1: The control range of the trigger level is related to the peak-peak value and duty cycle of the trigger signal. 1 - 18 CHARACTERISTICS CHARACTERISTICS 1.3.8 SPECIFICATION ADDITIONAL INFORMATION Logic Triggering Timing (Digital Mode Only) PATTERN/GLITCH DETECTION Max. pattern rate 150 MHz Min. present time PM3390B/94B 2 ns PM3380B/84B 4 ns PM3370B 6 ns range t1 range t2 accuracy t1 t2 20 ns, 30 ns, 40 ns, 50 ns to 0.16s 20 ns, 40 ns, 50 ns, 60 ns to 0.16s ±5 ns STATE DETECTION Max. state rate Min. setup time Min. hold time PM3370B/80B/90B: glitch detection only Pulse amplitude >2 div Pulse amplitude >2 div Pulse amplitude >2 div See note 1 See note 1 Not in PM3370B/80B/90B 150 MHz 2.5 ns 2.5 ns Pattern to clock Pattern to clock Note 1: Timing behavior around t1 and t2. Pattern valid time: ------|********|T T T T T T T T T T T T T T T T T T T|********|------t1+10 ns t2-10 ns t2 t1 - : not triggered undefined *T: :triggered 1.3.9 Trigger Accuracies TRIGGER LEVEL Accuracy edge ≤0.2 div At 1 MHz input signal D: Accuracy logic ≤0.4 div At 1 MHz input signal Trigger gap edge 0.4 div At 1 MHz input signal in noise trigger multiply by 2 FALSE TRIGGERS 1:100 000 See Note 1 Note 1: These values are not tested in production and are based on theoretical estimates and laboratory tests. CHARACTERISTICS CHARACTERISTICS 1 - 19 SPECIFICATION ADDITIONAL INFORMATION 1.4 EVENT COUNTER EVENT delay PM3384B/94B PM3370B/80B/90B Event count 1 to 16384 Event source PM3384B/94B PM3370B/80B/90B CH1 to CH4 CH1, CH2, EXT TRIG Event slope selection + or - Event clock sensitivity DC to 50 MHz 0.5 div Event level 8 div Max. count frequency 50 MHz In trigger modes EDGE and LOGIC. In trigger modes EDGE and GLITCH See Note 1 typical value Note 1: In digital mode, triggered DTB in combination with Event is not possible 1.5 HOLD-OFF HOLD OFF SETTING A: Minimum A: Maximum D: Minimum D: Maximum 2 µs or 3 divisions of MTB setting 2s or 20 divisions of MTB setting 4 ms 20 divisions of MTB setting Whichever is greater Whichever is smaller See Note 1 Note 1: For total hold off time, the process time must be included. See also ACQUISITION TIME. 1 - 20 CHARACTERISTICS CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION 1.6 PROCESSING 1.6.1 Preprocessing PREPROCESSING FUNCTIONS Invert Add Subtract D: D: D: Peak detection Average Envelope See Note 1 CH2; CH4 CH1+CH2; CH3+CH4; See Note 2 CH1-CH2; CH3-CH4; See Note 2 Real time only See Note 3 Note 1: These functions are performed before the acquisition data is stored in the acquisition registers. PM3370B/80B/90B; offer two channels, CH1 and CH2. Note 2: Dynamic range in digital mode ±5 div. Note 3: Average factor 2 to 4096 in power of 2 sequence. 1.6.2 Register Processing (Digital Mode) REGISTER PROCESSING FUNCTION Add Sub Mul Filter See Note 1 See Note 2 See Note 2 See Note 2 LF filter with adjustable -3dB point Note 1: There may be run two processes simultaneously. The acquisition registers can also be used as source registers. The result from process one will be stored in memory one. The result from process two will be stored in memory two. Note 2: The source can be any trace from any register except the result register. The result can be scaled. CHARACTERISTICS CHARACTERISTICS 1 - 21 SPECIFICATION ADDITIONAL INFORMATION 1.7 TRACE MEASUREMENTS (DIGITAL MODE) TRACE MEASUREMENTS FUNCTIONS Horizontal Vertical (with or without offset) See Note 1 Frequency Period Pulse width Rise / fall Mean RMS Maximum Minimum Peak/peak Low High Overshoot Preshoot Duty cycle Delay PM3370B/80B/90B: CH1, CH2 PM3370B/80B/90B: CH1, CH2 See Note 2 Note 1: These measurements can be performed on traces stored in the acquisition and memory registers. Note 2: In PM3370B/80B/90B also available for EXT trigger source and external trigger memory. 1 - 22 CHARACTERISTICS CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION 1.8 CURSORS 1.8.1 Cursor Control NUMBER OF CURSORS 4 CURSOR RELATION D: Screen Trace Free Follows the trace CURSOR MODES Time Amplitude Both Only screen cursor Absolute Ratio See Note 1 Absolute Ratio See Note 1 Amplitude cursor modes Time cursor modes Phase cursor Modes Absolute Ratio See Note 1 Note 1: The ratio range is 0% to 999% where 100% corresponds to the value in the cursor read out at the moment that the "∆T=100%" button is pressed. CHARACTERISTICS CHARACTERISTICS 1.8.2 1 - 23 SPECIFICATION ADDITIONAL INFORMATION Cursor Readouts CURSOR READOUTS READOUT RESOLUTION dV dT V to GND 1/dT dQ(Q1, Q2) T-trig See Note 1 See Note 1 See Note 2 See Note 3 3 digits Note 1: In the "MTB + DTB timebase" and "DTB", all waveform operations and measurements are performed on the DTB traces. Note 2: Refer to trigger point (Q1, Q2) Refer to start of trace (Trace in memory, Q1 and Q2). Note 3: Gives time differences (delta) between the cursor position and the trigger point (for both cursors). 1.8.3 Cursor Accuracies ( Analog Mode) Voltage measurements Manual ±1% of FULL SCALE Note 1 Time measurements Unmagnified timebase ±1% of FULL SCALE Magnified timebase up to 10 ns/div ±1.4% of FULL SCALE Magnified timebase in 5 ns/div and 2 ns/div ±2.2% of FULL SCALE Note 2 Note 1: Measured with 1 kHz square wave within central 6 div. Note 2: within central 8 div. 1.8.4 Cursor Accuracies (Digital Mode) ERROR LIMIT VERTICAL See vertical accuracy ERROR LIMIT HORIZONTAL See horizontal accuracy 1 - 24 CHARACTERISTICS CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION 1.9 DIGITAL ACQUISITION 1.9.1 Modes MODES Select one: 1.9.2 Recurrent Single shot/scan Roll Stop on trigger continuous Sample Rate Real time Max. Sample rate 200MS/s 250 ns/div to 200s/div See Note 1 Equivalent time: Random sampling See Note 1 PM3390B/94B PM3370B/80B/84B Max. 25GS/s Max. 10GS/s 2 ns/div to 0.2 µs/div 5 ns/div to 0.2 µs/div Note 1: Sampling rate depends on time/division setting. 1.9.3 Multiplexed Channels The 4 channel instruments have 4 channels configured as 2 + 2. This implies, that the channels CH1 and CH2 are multiplexed with the channels CH3 and CH4 to share the same dual channel digitizer. The Ext.Trig. channel (TRIG VIEW) is multiplexed the same way as CH4. Multiplexed channels (CH1 and CH2) or (CH3 and CH4) Any other combination for timebase settings 200s/div to 10 µs/div 5 µs/div to 2 ns/div Max. Chop freq. simultaneously See Note 1 CHOPPED ALTERNATED See Note 2 5 MHz Note 1: At 250 ns/div each of the four channels is acquired in alternated mode. Note 2: When peak detection is activated the multiplexing is in alternating mode. CHARACTERISTICS CHARACTERISTICS 1.9.4 1 - 25 SPECIFICATION ADDITIONAL INFORMATION Trace Memory PM3384B/PM3394B This digitizer has a total acquisition memory size of 32K bytes. To apply this memory as efficiently as possible, it is shared by all channels connected to it. The following section summarizes the effects: Record length normal 1 to 4 channels selected 512 samples/channel Record length ’Max’ 3 or 4 channels selected 2 of 4 channels selected 1 of 4 channels selected 8K samples/channel 16K samples/channel 32K samples Display 501 samples/trace See Note 1 PM3370B/80B/90B: This digitizer has a total acquisition memory size of 8K bytes. To apply this memory as efficiently as possible, it is shared by all channels connected to it. The following section summarizes the effects: Record length normal 1 and 2 channels selected 512 samples/channel See Note 2 Record length ’Max’ 2 channels selected 2 channels selected 1 of 2 channels selected 2K samples/channel 4K samples/channel 8K samples See Note 1 and 4 See Note 2 See Note 3 See Note 3 Display 501 samples/trace Note 1: When peak detection or envelope is activated, all "max" record length figures have to be divided by 2 because samples are stored as peak/peak combinations. Note 2: Trigger view possible. Note 3: No trigger view possible. Note 4: When extended memory option is installed total acquisition memory is 32K bytes, shared by both channels and external trigger. This results in the following max. record lengths: 2 channels and trig.view 8K samples/channel. 2 channels, no trig.view 16K samples/channel. 1 of 2 channels, no trig.view 32K samples/channel. 1 - 26 CHARACTERISTICS CHARACTERISTICS 1.9.5 SPECIFICATION ADDITIONAL INFORMATION Acquisition Time The process time between acquisitions depends from the selected settings and the selected processing. Therefore it is not possible to catch the process time between acquisitions in a formula. The next table gives an indication of the performance of the processing capabilities. Process time between acquisitions 500 ns/div one channel no trigger delay acquisition length = 512 500 ns/div two channel no trigger delay acquisition length = 512 average = 8 Equivalent time Timebase: - at 2 ns/div - at 0.2 µs/div 6 ms 16 ms See Note 1 Holdoff is min and no processes or measurements are active Holdoff is min and no other processes or measurements are active See Note 2 2s 100 ms Note 1: Time required to fill the acquisition record at the sampling rate corresponding with the selected timebase setting is not included. Note 2: After the specified time, there is a 99% probability of all sample positions being updated to the new acquisition. Trigger frequency >2 kHz. These values are not tested in production and are based on theoretical estimates and laboratory tests. 1.9.6 Resolution ACQUISITION RESOLUTION 8 bits over 10.24 divisions CHARACTERISTICS CHARACTERISTICS 1.9.7 1 - 27 SPECIFICATION ADDITIONAL INFORMATION Registers NUMBER OF REGISTERS Acquisition length: PM3384B/94B: - Normal - Max: -4x8K -2x16K -1x32K WORD LENGTH PM3370B/80B/90B: - Normal - Max: -2x2K -2x4K -1x8K WORD LENGTH Including current acquisition One set contains: 51 sets 3 sets Four traces Four traces Two traces One trace 16 bits 9 sets 3 sets Note 1 Two traces Two traces Two traces One trace + Trig. View 16 bits Note1: When extended memory installed: number of register, equal to four channel models. One set contains max. two traces+ trig.view. 1.9.8 Clear Save Copy Recall Register Manipulations The contents of the selected register is set to zero The contents of the acquisition register is stored in the selected register The contents of a selected register is stored in another selected register The register can be made visible on the display or can be removed from the display 1 - 28 CHARACTERISTICS CHARACTERISTICS 1.9.9 SPECIFICATION ADDITIONAL INFORMATION Digital Acquisition Accuracies SAMPLING RATE ERROR ±0.01% TIME UNCERTAINTY At double sampling rate ±100ps X-tal 1.10 FRONT PANEL MEMORY Memory size 10 fronts 1.11 BLANKING OR Z-AXIS (ONLY FOR ANALOG TRACE) Input connector Input impedance Input coupling Max input voltage Input voltage unblank Input voltage blanked Response time BNC 10 kΩ dc ±10V 0.5V or less + 2.4 V or more 80 ns See Note 1 See Note 1 Rise time 2 ns Note 1: Half tones are possible at input voltages between +0.8V and +2.4 V. Blanking has only effect on the trace in analog mode. CHARACTERISTICS CHARACTERISTICS 1 - 29 SPECIFICATION ADDITIONAL INFORMATION Electrostatic 80 mm x 100 mm Vector 8 x 10 divisions 1.12 DISPLAY 1.12.1 CRT CRT Deflection Dimensions (hxw) Phospor Standard GRATICULE Y-AXIS ORTHOGONALITY ACCELERATING VOLTAGE Writing speed TRACE ROTATION Min. range Min. overrange Green GH (P31) Fixed 90 ° ±0.5 ° 16.5 kV >1.8cm/ns 10 ° 2° TRACE DISTORTION At center of screen <0.3 mm Else <1.0 mm 1.12.2 Modes PRESENTATION MODES Y versus T Y versus X Screwdriver adjustment External field <0.1 mT Deviation from straight line inside 6 x 8 div 1 - 30 CHARACTERISTICS CHARACTERISTICS 1.12.3 SPECIFICATION ADDITIONAL INFORMATION Vertical Display Manipulations (Digital Mode) Linear Linear interpolations between measured dots Sine like interpolation between measured dots Sine Vertical magnify 2, 4, 8, 16, 32 Windows 1, 2, 4 PM3384B/94B PM3370B/80B/90B Recall trace Each trace has his own place on the screen max. 4 traces max. 3 traces Each trace can be made visible on the screen or can be removed from the screen. Note 1 Vertical position ± 8 div Each trace can be moved over 8 divisions Max. displayable traces on screen 8 See Note 1 Note 1: At least one trace is visible. 1.12.4 Horizontal Display Manipulations (Digital Mode) TIMEBASE MAGNIFICATION 2, 4, 8, 16, 32 See Note 1 Note 1: For acquisition depth greater than 512 byte it is possible to make the magnification factor less than one (compress mode) to display the complete trace on the screen. CHARACTERISTICS CHARACTERISTICS 1 - 31 SPECIFICATION ADDITIONAL INFORMATION 1.13 EXTERNAL INTERFACES 1.13.1 Calibrator WAVEFORM Shape square wave INTERNAL IMPEDANCE Value 1200Ω OUTPUT VOLTAGE Peak-peak value Tolerance 600 mV 1% See Note 1 OUTPUT CURRENT Peak-peak value 0.5 mA See Note 2 FREQUENCY Value Tolerance 2kHz ±20% Note 1: Positive going with respect to ground; Open voltage (halves when terminated with 1200Ω). Note 2: When output short circuited (halves when terminated with 1200Ω). 1.13.2 Standard external interface TYPE OF INTERFACERS 232-C PINNING PIN 1 2 3 4 5 6 7 8 9 I/O I O O I O I - NAME RXD TXD DTR GND DSR RTS CTS - CPL (compact programming language) See operating guide Not connected Received data Transmitted data Data terminal ready Signal ground Data set ready Request to send Clear to send Not connected 1 - 32 CHARACTERISTICS CHARACTERISTICS SPECIFICATION TRANSMISSION MODES Asynchronous Full duplex HANDSHAKE Hardware ADDITIONAL INFORMATION RTS/CTS and DSR/DTR XON/XOFF Default: not active See Note 1 Default: not active See See Note 1 BAUDRATE 75,110,150,300 600,1200,2000, 2400,4800,9600 19200,38400 Receiving and transmitting Default:1200 See Note 1 NUMBER OF STOP BITS 1 PARITY odd,even,or no Default: no parity See Note 1 CHARACTER LENGTH 7 or 8 Default:8 See Note 1 ERROR RESPONSE See CPL, Chapter 6 in Users Manual Software ELECTRICAL TXD and RXD Spacing "0" Marking "1" ≥ +3V ≤ -3V RTS,CTS,DSR and DTR ON OFF ≥ +3V ≤ -3V Current output ≤10mA Impedance Output Input 300Ω ±10% ≥3 kΩ ≤7kΩ Voltage Output Input ≥ -12V ≤ +12V ≥ -25V ≤ +25V Connector Shielded 9 pole RAP male connector according MIL-C-24308 Note 1: Selectabele via UTILITY menu and CPL. When battery installed, same as last power-off value. CHARACTERISTICS CHARACTERISTICS 1.13.3 SPECIFICATION ANSI/IEEE 488.2 SCPI See section 1.20.5 Printers and plotters support PRINTERS HP-thinktjet LQ1500 FX80 HP-LASER HP-540 PLOTTERS HPGL HP7440 HP7550 HP7475A HP7478A PM8277 PM8278 1.13.5 ADDITIONAL INFORMATION Optional external interfaces IEEE 1.13.4 1 - 33 Real Time Clock (RTC) Select: Time of trigger or Time of pressing hardcopy button Note 1 Note 2 Note1: These times may be the same when it is not possible to reconstruct the time of trigger. Note2: - Stamped on any hardcopy via hardcopybutton - Time is part of delta transfer waveform. 1 - 34 CHARACTERISTICS CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION 1.14 AUTO SET & CALIBRATION 1.14.1 Auto Set Vertical deflection 2...5 div Note 1 Horizontal deflection Max. 6 periods on CRT at input signal 10 mV...25V 40 Hz...30 MHz Note 1 Note 1: AUTO SET selects the proper channel, sets vertical deflection, timebase speed, intensity, and triggering for an easy-to-read display of input signals, or the user programble AUTO SET items. 1.14.2 Calibration CALIBRATION FACILITIES Auto cal See Note 1 Note 1: Calibrates vertical offset and gain, horizontal offset and gain and sweep time, trigger offset and gain. 1.15 POWER SUPPLY AND BATTERY BACKUP 1.15.1 Power Supply LINE VOLTAGE ac (rms) Operation Tolerance 100V to 240V ±10% LINE FREQUENCY Nominal Limits of operation 50 Hz to 400 Hz 45 Hz to 440 Hz LINE WAVEFORM Max. waveform deviation factor Crest factor CAT II Pol 2 At nominal source voltage 10% 1.27 to 1.56 CHARACTERISTICS 1 - 35 CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION ALLOWABLE POWER INTERRUPTION 20 ms See Note 1 POWER CONSUMPTION Without options Max. power consumption 130W POWER CORD Length Power plug 2.1m (82.7 in) Nat.version 115W Note 1: At the lowest allowable source voltage. After this time the oscilloscope data is saved before the instrument goes down, and an automatic poweron sequence starts after restoration of the power source voltage. 1.15.2 Battery Backup DATA AND SETTINGS RETENTION See Note 1 Retention time Batteries: Recommended type Quantity 2 years LR 6 2 See Note 2 Temperature range 0..+70 °C See Note 3 Note 1: When instrument is switched off or during power failure. Note 2: According to IEC 285 (=Alkaline Manganese Penlight Battery). Note 3: At -40 to 0 °C, settings retention is uncertain. It is advised to remove batteries from instrument when it is stored during longer periods (>24 hours) below -30 °C or above 60 °C. UNDER NO CIRCUMSTANCES SHOULD BATTERIES BE LEFT IN THE INSTRUMENT AT TEMPERATURES BEYOND THE RATED RANGE OF THE BATTERY SPECIFICATION 1 - 36 CHARACTERISTICS CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION 1.16 MECHANICAL CHARACTERISTICS PORTABLE VERSION Dimensions: Length 481 mm (19 in) Width 341 mm (13,5 in) Height 139 mm ( 5,5 in) Weight: Instrument 9.5 kg (19,7 lb) COOLING Regulated Forced air Handles excluded Add 5 mm (0.2 in) for cover Add 65 mm (2.5 in) for handle Add 50 mm (2 in) for handle Add 8 mm (0.3 in) for feet No air filter 1.17 ENVIRONMENTAL CHARACTERISTICS 1.17.1 General The characteristics are valid only if instrument is checked in accordance with the official checking procedure. Warm up and recovery time are in accordance with MIL-T 28800D par. 3.7.1.1. The instrument meets the environmental requirements of MIL-T-28800D Type III Class 3, Style D, Color R (unless specified otherwise). 1.17.2 Environmental TEMPERATURE Operating: min.low temp. max.high temp. Nonoperating (storage): min. low temp. max. high temp. See Note 1 0 °C +50 °C -40 °C +70 °C CHARACTERISTICS CHARACTERISTICS MAX. HUMIDITY Operating and Non operating (storage) MAX. ALTITUDE Operating Nonoperating (storage) 1 - 37 SPECIFICATION See Note 1 95% 3 km (10000 ft) Relative humidity noncondensing See Note 2 See Note 3 12 km (39000 ft) VIBRATION (OPERATING) Freq. ranges: At each freq.range: Cycling time Resonance search Resonance dwell ADDITIONAL INFORMATION 5 Hz to 15 Hz 16 Hz to 25 Hz 26 Hz to 55Hz See Note 4 g level at max. freq.: 0.7 at 15 Hz 1.3 at 25 Hz 3 at 55 Hz 15 min 5 min 10 min See Note 5 Note 1: In accordance with MIL-T-28800D par. 3.7.2.1.1. (FIGURE 2). Note 2: In accordance with MIL-T 28800D par. 3.7.3. Note 3: Maximum operating temperature derated to 3 °C for each km above sea level Note 4: In accordance with MIL-T-28800D par. 3.7.4.1. Note 5: At each resonance frequency (or at 33 Hz if no resonance was found). SHOCK (OPERATING) Amount of shocks total each axis Shock waveform Duration Peak acceleration BENCH HANDLING Meets requirements of See Note 6 18 6 half sinewave 6-9 ms 400 m/s2 3 in each direction See Note 7 MIL-ST-810 method 516 procedure V 1 - 38 CHARACTERISTICS CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION TRANSPORTATION Drop height 0.76m See Note 9 SALT ATMOSPHERE Structural parts See Note 8 Note 6: In accordance with MIL-T-28800 par. 3.7.5.1. Note 7: In accordance with MIL-T-28800 par. 3.7.5.3. Note 8: In accordance with MIL-T-28800 par. 3.7.8.1. Note 9: Drop in shipping container on 8 corners, 12 edges, 6 surfaces. 1.17.3 1.17.3.1 EMI Meets MIL-T 28800D Type III Class 3 (Navy requirement, unless specified otherwise). Meets MIL-STD-461C as follows: - Conducted Emissions Part 2 Part 4 - Conducted Susceptibility Part 2 Part 5 - Radiated Emissions Part 5,6 Part 2 1.17.3.2 CEO1 CEO3 CSO1 CSO6 REO1 REO2 (Narrow band) (Limited to 300V) (1 GHz max) CE (89/336EEC) Meets harmonized product requirements of 89/336EEC, EN50081.1 and EN50082.1 with addition of the tables 1 to 8. 1.17.3.3 Additional EMI requirements The instrument is tested in accordance with IEC 351-1 par. 5.1.3.1. The maximum deflection factor is 7 mm/mT (0.7 mm/gauss). This value measured with the instrument in a homogeneous field (in any direction with respect to the instrument) with a flux intensity (peak to peak value) of 1.42 mT (14.2 gauss) and of symmetrical sine wave form with a frequency of 45 Hz to 66 Hz. CHARACTERISTICS 1 - 39 The PM3370B, PM3380B and SPECIFICATION PM3384B, including standard accessories, CHARACTERISTICS ADDITIONAL conform with the EEC Directive 89/336 for EMI immunity, as defined by EN50081INFORMATION 1 (1992) and EN50082-1 (1992), with the addition of the following tables. Table 1. Susceptibility: no visible disturbance Frequency range: 10 kHz .. 25 MHz E = < 0.1V/m E = 1 V/m E = 3 V/m Stand alone 2 mV/div ... 5 V/div 2 mV/div ... 5 V/div 2 mV/div ... 5 V/div With PM9010/09x 2 mV/div ... 5 V/div 20 mV/div ... 5 V/div 100 mV/div ... 5 V/div Table 2. Susceptibility: no visible disturbance Frequency range: 25 MHz ... 1 GHz E = < 0.1V/m E = 1 V/m E = 3 V/m Stand alone 2 mV/div ... 5 V/div 2 mV/div ... 5 V/div 10 mV/div ... 5 V/div With PM9010/09x 2 mV/div ... 5 V/div 100 mV/div ... 5 V/div 500 mV/div ... 5 V/div Table 3. Susceptibility: disturbance less than 10 % of full scale Frequency range: 10 kHz .. 25 MHz E = < 0.1V/m E = 1V/m E = 3 V/m Stand alone N/A N/A N/A With PM9010/09x N/A 5 mV/div ... 10 mV/div 20 mV/div ... 50mV/div Table 4. Susceptibility: disturbance less than 10 % of full scale Frequency range: 25 MHz ... 1 GHz E = < 0.1V/m E = 1V/m E = 3 V/m Stand alone N/A N/A 2 mV/div ... 5 mV/div With PM9010/09x N/A 20 mV/div ... 50 mV/div 50 mV/div .... 200 mV/div For conditions not specified in tables 1 - 4, a susceptibility effect of more than 10 % is possible. 1 - 40 CHARACTERISTICS The PM3390B and PM3394B, SPECIFICATION including standard accessories, conform with the CHARACTERISTICS ADDITIONAL EEC Directive 89/336 for EMI immunity, as defined by EN50081-1 (1992) and INFORMATION EN50082-1 (1992), with the addition of the following tables. Table 5. Susceptibility: no visible disturbance Frequency range: 10 kHz .. 25 MHz E = < 0.1V/m E = 1 V/m E = 3 V/m Stand alone 2 mV/div ... 5 V/div 2 mV/div ... 5 V/div 2 mV/div ... 5 V/div With PM9020/09x 2 mV/div ... 5 V/div 20 mV/div ... 5 V/div 50 mV/div ... 5 V/div Table 6. Susceptibility: no visible disturbance Frequency range: 25 MHz ... 1 GHz E = < 0.1V/m E = 1 V/m E = 3 V/m Stand alone 2 mV/div ... 5 V/div 2 mV/div ... 5 V/div 10 mV/div ... 5 V/div With PM9020/09x 2 mV/div ... 5 V/div 100 mV/div ... 5 V/div 200 mV/div ... 5 V/div Table 7. Susceptibility: disturbance less than 10 % of full scale Frequency range: 10 kHz.. 25 MHz E = < 0.1V/m E = 1V/m E = 3 V/m Stand alone N/A N/A N/A With PM9020/09x N/A 5 mV/div ... 10 mV/div 10 mV/div ... 20 mV/div Table 8. Susceptibility: disturbance less than 10 % of full scale Frequency range: 25 MHz ... 1 GHz E = < 0.1V/m E = 1V/m E = 3 V/m Stand alone N/A N/A 5 mV/div With PM9020/09x N/A 20 mV/div ... 50 mV/div 50 mV/div ... 100 mV/div For conditions not specified in tables 5-8,, a susceptibility effect of more than 10 % is possible. CHARACTERISTICS CHARACTERISTICS 1 - 41 SPECIFICATION ADDITIONAL INFORMATION EN61010-1, Cat II Pol 2 Except for power cord, unless shipped with Universal European power plug UL 3111-1, Cat II Pol 2 Except for power cord, unless shipped with Universal North American power plug CSA C22.2 No.1010.1-92, Cat II Pol 2 Except for power cord, unless shipped with Universal North American power plug 1.18 SAFETY Meets requirements of Installation Category II refers to local level, which is applicable for appliances, and portable equipment. APPROVALS (applied for) CSA C22.2 No. 1010.1 MAX. X-RADIATION MIL-T-28800D par. 3.9.3.4.a 1.19 ACCESSORIES PACKED WITH INSTRUMENT Signal input Operating guide Reference manual 2x10 MΩ 10:1 probe Contrast filter Front cover With readout (1.5 m) Blue Can be locked on instr. 1 - 42 CHARACTERISTICS CHARACTERISTICS SPECIFICATION ADDITIONAL INFORMATION 1.20 OPTIONS & OPTIONAL VERSIONS 1.20.1 Options Line cord LINE CORD 1.20.2 In accordance with EN North American In accordance with CSA, UL United Kingdom In accordance with BSI Australian In accordance with SAA Swiss In accordance with SAV Options digital versions EXTERNAL INTERFACES INTERNAL EXTENSIONS 1.20.3 Universal European IEEE EXTENDED MEMORY MATH+ Factory installed only Factory installed only Factory installed only Y-out, MTB gate, DTB-gate, ExtTrig. IEEE See Note 1, Factory installed only Factory installed only Options analog EXTERNAL INTERFACES Note 1: Ext trig is a standard feature in PM3370B/80B/90B. For characteristics refer to chapter 1.3.5. CHARACTERISTICS CHARACTERISTICS 1.20.4 1 - 43 SPECIFICATION ADDITIONAL INFORMATION Specification optional outputs Y SIGNAL OUT Source Coupling Voltage: into 1 MΩ into 50Ω Freq. response: PM3390B/94B PM3380B/84B PM3370B Dynamic range MTB GATE OUT Connector Output impedance Voltage:Timebase not running Timebase running DTB GATE OUT Connector Output impedance Voltage:Timebase not running Timebase running BNC CH1 as CH1 20mV/div ±10% 10mV/div ±10% Terminated with 50Ω dc to 200 MHz dc to 100 MHz dc to 60 MHz ±10 div BNC 1 kΩ 0.2 ± 0.2V 3.7 ± 1.3V BNC 1 kΩ 0.2 ± 0.2V 3.7 ± 1.3V At 50 MHz 1 - 44 CHARACTERISTICS CHARACTERISTICS 1.20.5 SPECIFICATION ADDITIONAL INFORMATION Specification External trigger option Valid for ext trig option in PM3384B/94B (External trigger input is a standard feature in PM3370B/80B/90B) SOURCE SOURCE(S) MTB-triggering CH1 ... CH4 External Line INPUT CHARACTERISTICS INPUT CONNECTOR BNC INPUT IMPEDANCE At rear of instrument Measured at freg. <1MHz R parallel - value - tolerance C parallel - value - tolerance 1 MΩ ±1% 25 pF ±5 pF DYNAMIC RANGE Up to 10 MHz ±2.5V MAX. INPUT VOLTAGE Max. input voltage 150 V rms Symmetrical See note 1,2 According to EN61010-1 Cat II Pol 2. Note 1: Apparaturs should be properly grounded through the protective ground conductor of the power cord. Note 2: Up to 20 kHz; >20 kHz see figure 1.1. SENSITIVITY EDGE TRIGGER SENSITIVITY d.c. to 5 MHz 100 mV d.c. to 10 MHz 200 mV Note 3: In noise-trigger multiply stated value by 2. See note 3 CHARACTERISTICS CHARACTERISTICS 1 - 45 SPECIFICATION ADDITIONAL INFORMATION ±1.45V ≤0.45V See note 4 at 1 kHz input signal triggercoupling DC TRIGGER LEVEL TRIGGERLEVEL Range Accuracy Note 4: With Level-pp on the range is restricted to the peak-peak value of the trigger signal. 1.20.6 Specification IEEE-OPTION TYPE OF INTERFACE ANSI/IEEE 488.2 SCPI (see SCPI programming manual) See Note 1 INTERFACE REPERTORY Source handshake Acceptor handshake Talker SH1 AH1 T5 Listener L3 Service request Remote local Parallel poll Device clear Device trigger Controller SR1 RL1 PP0 DC1 DT1 C0 Complete capability Complete capability Basic talker: yes Serial poll : yes Talk only : yes Unaddress if MLA: yes Basic listerner: yes Listener only : yes Unaddress if MTA: yes Complete capability Complete capability No capability Complete capability Complete capability No capability 1 - 46 CHARACTERISTICS ELECTRICAL INTERFACE CHARACTERISTICS Busdrivers SPECIFICATION E2 ADDITIONAL Three state (true=0 INFORMATION to 0.8V;false=2 to 5V) Connector Shielded Amphenol type 57FE-20240-20SD35 Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin DIO1...DIO4 DIO5...DIO8 GND Logic GND EOI DAV NRFD NDAC IFC SRQ ATN Shield REN 1 ... 4 13 ... 16 18 ... 23 24 5 6 7 8 9 10 11 12 17 FUNCTION SELECTION Via UTILITY-MENU INTERFACE STATUS INDICATOR On screen Busaddress Default: 8 See Note 2 Note 1: Talker/listener Note 2: When battery installed, same as last power-off value. 2-4 Figure 2.1 PRINCIPLE OF OPERATION Blockdiagram PRINCIPLE OF OPERATION 2-1 2 PRINCIPLE OF OPERATION 2.1 INTRODUCTION This chapter describes the principle of operation and should be read in combination with the block diagram in figure 2.1. The block diagram shows the user in which sections of the oscilloscope circuitry the controls and keys are operating, and how signals are routed. For a detailed description of each function, refer to chapter 5 ’Function Reference’ in the Operating Guide. Lines between controls/keys and the block they are operating are interrupted. The text ’µC’ at the interruption indicates that the control operates the block via the microComputer. 2.2 CONTROL SECTION The heart of the control section is formed by a MICROCOMPUTER with an incorporated RS-232 interface. The MICROCOMPUTER reads all the keys (except POWER ON/OFF) and rotary controls. It sends control signals to the oscilloscope circuits to put them in the desired mode. Control of the oscilloscope functions can also be done by an external computer connected to the RS-232 CONNECTOR. 2.3 VERTICAL DEFLECTION This section consists of the blocks VERTICAL CHANNELS and FINAL VERTICAL AMPLIFIER. There are four vertical channels. In PM3370B/80B/90B there are two vertical channels, CH1 and CH2, and an External Trigger (Trigger View) channel. Small differences between the channels depend on instrument versions. The inputs CH1 ... CH4 are applied to the block VERTICAL CHANNELS. In this block the following functions are made: - - Input coupling can be switched between AC, DC and GND. As an extra 50Ω input impedance can be selected in the 200 MHz models via the VERT MENU key. The AMPL/VAR key pair determines the input sensitivity of each channel. The most suitable input sensitivity is selected automativally if AUTO RANGE is active. Some channels may have a switch to toggle between the two most commonly used input sensitivities. 2-2 - - PRINCIPLE OF OPERATION Each channel can be switched on/off with the ON key and bandwidth can be limited to 20 MHz via BW LIMIT ’on’ in the VERT MENU. Trigger source selection for MTB and DTB is done via the keys TRIG1 ... TRIG4 and the menu under the DTB key. PM3370B/80B/90B offer trigger source selection via TRIG1, TRIG2 and EXT TRIG. The vertical signal position of each channel can be adjusted with a POS control. The FINAL VERTICAL AMPLIFIER drives the vertical deflection system of the Cathode Ray Tube (CRT). The TRACE SEPARATION key pair adjusts the vertical distance between MTB and DTB display, when in Alternate Timebase Mode. 2.4 HORIZONTAL DEFLECTION The horizontal deflection consists of the blocks TRIGGERING, TIMEBASE and FINAL VERTICAL AMPLIFIER. TRIGGERING and TIMEBASE are both split up in sections for MTB and DTB; these sections are almost identical. Triggering can be done via CH1 ... CH4 (PM3370B/80B/90B; CH1, CH2, EXT TRIG) or a signal derived from the line voltage. The following controls adjust the triggering: - COUPLING permits selection between ac, dc, lf-reject, hf-reject and noise suppression. SLOPE permits triggering on positive- or negative-going signal edges. LEVEL adjusts the signal level where the timebase is started. The output of the TRIGGERING generates a pulse that starts the TIMEBASE. The TIMEBASE generates a so-called sawtooth signal that gives a time linear horizontal display on the CRT. The following controls influence the timebase: - - MTB/VAR and DTB adjust the horizontal time scale of MTB and DTB. The best MTB time scale is selected automatically if AUTO RANGE is active. The TB MODE key permits selection between auto (free run), trig(gered) and single (shot) mode of MTB. The SINGLE RESET key resets the MTB when in single shot mode. The DTB key permits selection of the operating modes of the DTB. The HOLD OFF control adjusts the period of time that the MTB does not start upon receipt of a trigger. The DELAY control adjusts the time delay between start of MTB and DTB. X POS controls the horizontal position of the signal display. PRINCIPLE OF OPERATION 2-3 2.5 CRT DISPLAY SECTION This section determines the intensity and focusing of the signal on the screen. The intensity of trace and text/cursors can be adjusted separately with the controls TRACE INTENSITY and TEXT INTENSITY. The FOCUS control determines the sharpness of text and traces. Moreover focusing is controlled such that changes in intensity do not affect display sharpness. 2.6 POWER SUPPLY This POWER SUPPLY converts a wide range of line input voltages into stable supply voltages that feed the circuits in the oscilloscope. Also the very high voltages for the CRT are made by the power supply. Another output signal is used to trigger the MTB if ’line’ is selected as trigger source. Memories in the oscilloscope are supplied by a MEMORY BACKUP battery if line voltage is switched off. 2.7 DIGITIZER SECTION In DIGITAL MODE the CH1 ... CH4 (PM3370B/80B/90B; CH1, CH2 and TRIG VIEW) input signals are applied to the DIGITIZER AND TEXT GENERATOR where they are digitized and stored in a memory. The signal storage is initiated by pulses from the TRIGGERING. Also the generation of text/cursors is done in the block DIGITIZER AND TEXT GENERATOR. For display on the CRT, the digital information is converted into analog and applied to the final amplifiers for VERTICAL and HORIZONTAL deflection. The FOCUS and INTENSITY parts are controlled in a similar way. Switching between ANALOG MODE and DIGITAL MODE is done via the ANA/DIGI switches that are operated by the DIGITIZER AND TEXT GENERATOR. The switches are incorporated in the inputs of the output stages of Final Y, Final X, Intensity and Focusing. BRIEF CHECKING PROCEDURE 3-1 3 BRIEF CHECKING PROCEDURE 3.1 General information This procedure is intended to verify the instrument’s functions with a minimum of test steps and actions required. It is assumed that the operator doing this test is familiar with this kind of instruments and their characteristics. WARNING: Before turning on the instrument, ensure that it has been installed in accordance with the instructions mentioned in Chapter 2 of the Operation Guide. NOTE: The procedure does not verify every facet of the instrument’s calibration; rather, it is concerned primarily with those parts of the instrument that are essential to measurement accuracy and correct operation. Removing the instrument covers is not necessary to perform this procedure. All checks are made from the outside of the instrument. If this test is started a few minutes after turning on the instrument, test steps may be out of specification, due to insufficient warm-up time. Be sure to allow the full warm-up time of 30 minutes (under average conditions). The check is set up in a logical sequence. For a complete check of every facet of the instrument’s calibration, refer to the ‘PERFORMANCE TEST’ section in Chapter 4 of this Reference Manual (for qualified persons only). The check can be used for different instrument types. Where differences exist, they are indicated (e.g., in the vertical channels). Those test steps can be skipped. 3.2 Preliminary settings of the controls For ease of reading the following abbreviations are used: CW CCW CRT MTB DTB = Clockwise (rotation direction of a control) = Counter Clockwise (rotation direction of a rotary control) = Cathode Ray Tube (the oscilloscope’s viewing area) = MAIN TB = DELAYED TIMEBASE, DEL’D TB 3-2 BRIEF CHECKING PROCEDURE Trace alignment: - Turn the oscilloscope on with the POWER ON OFF key. - Press the STATUS and TEXT OFF keys simultaneously. This ensures that the oscilloscope is in the default mode. The default mode is the basis of this brief checking procedure. - Press the AUTOSET key. - Turn the TRACE INTENSITY control so that a clearly visible horizontal line appears on the CRT. - Press the TEXT OFF key when no text is present on the CRT. Turn the TEXT INTENSITY control so that clearly visible text appears on the CRT. - Turn the FOCUS control to make the line and text look as sharp as possible across the CRT area. - Turn the GRATICULE ILLUMINATION control so that the desired illumination of the measuring graticule is obtained. - Verify that the trace on the CRT is exactly parallel to the horizontal lines of the measuring raster; if not, correct this with a small screwdriver on the TRACE ROTATION control. Instrument calibration. Press the CAL key for two seconds: this starts the AUTOCALibration procedure. Wait until the normal display appears again. The oscilloscope calibration is now optimized. Probe adjustment: - Connect a 10 : 1 probe to the CH1 input. - Connect the probe tip to the Probe Adjust output socket. - Press the green AUTOSET key. - Verify that a square-wave signal is displayed on the CRT. - Verify that top and bottom of the square wave are straight: if not, this must be corrected by adjusting the probe. The correction is done with a small screwdriver. This adjustment is made in the box at the oscilloscope input side of the probe: refer to figure 3.1 for this. BRIEF CHECKING PROCEDURE 3-3 ST6024 9303 Figure 3.1 Probe adjustment Note : - The POS CH1, POS CH2, POS CH3, POS CH4 and X POS controls need occasional readjustment during this procedure to align the waveform with the measuring raster. - Small readjustments of the TRACE INTENSITY, TEXT INTENSITY and FOCUS controls may also be necessary. - Information about active instrument settings is indicated on the viewing area as shown in Fig. 3.2. 3-4 BRIEF CHECKING PROCEDURE Repeatedly pressing the TEXT OFF key allows you to select the amount of information on the display. CURSORS DTB DISPLAY CURSOR MENU HEADER CURSOR READ OUT TB MODE TRIGGER .... SOFTKEYS SETTINGS READ OUT SYMBOLS: ↓ :INVERT ON = :DC COUPLED INPUT :AC COUPLED INPUT :GROUNDED INPUT :POS TRIGGER SLOPE :NEG TRIGGER SLOPE :DUAL SLOPE (DIGITAL MODE) Figure 3.2 ST6648 9312 CRT viewing area, softkeys, menu keys, and symbols used in this chapter. 3.3 Vertical section The vertical section consists of four channels CH1, CH2, CH3 and CH4. The vertical section in PM3370B/80B/90B consists of two channels CH1 and CH2 that must be checked. These are almost identical. The procedure is described for CH1. Steps for CH2, CH3 and CH4 are shown in parenthesies. To check all four or two channels, the procedure must be done four or two times. For PM3370A/ 80A/90A this section includes a separate check of the EXT TRIG input and TRIG VIEW function. Differences in the keys for AC/DC input coupling, grounded trace (GND) and 50Ω input impedance may exist. This is indicated in the text. These test steps may be skipped. Proceed as follows: Preparation: - Connect a probe to the CH1 (CH2, CH3, CH4) input. - Connect the probe tip to the Probe Adjust output socket. - Press the AUTOSET key. BRIEF CHECKING PROCEDURE - 3-5 The Probe Adjust output square-wave voltage should be well triggered. The waveform must be easy to read. Press the ANALOG key (’DIGITAL MODE’ is displayed briefly): the oscilloscope is now in digital mode. Press the AUTOSET key again. Adjust the AMPL keys to an input sensitivity of 100mV/div. Adjust the MAIN TB TIME/DIV keys pair to 100 µs/div. Verify that a square wave as indicated in Fig. 3.3 is displayed. CH... 100mV CH...100mV MTB 100µs Figure 3.3 MTB 100µs ST6651 ST6649 Figure 3.4 Input coupling and POS control: - Press the AC/DC/GND key so that dc input coupling (=) is obtained. - Verify that this results in an upward signal shift. Fig. 3.4 shows this for channels with 100mV input sensitivity: the shift is 3 divisions. Fig. 3.6 shows this for channels with 1.00 V input sensitivity: the shift is 0.3 divisions. - Turn the POS control CCW until the display of Fig. 3.3 is obtained again. - Press the AC/DC/GND key so that GND input coupling (⊥) is obtained. - Verify that this results in a horizontal line in the lower part of the CRT. - Turn the POS control CW until the line is in the middle of the screen. - Press the AC/DC/GND key so that ac input coupling ( ) is obtained. The waveform as indicated in Fig. 3.3 is displayed again. 3-6 BRIEF CHECKING PROCEDURE AMPL and VAR functions (this test is skipped for channels where AMPL is a toggle key): - Press the lower AMPL key and verify that the signal amplitude is 3 divisions. The input sensitivity is 200mV/div. - Press the upper AMPL key twice and verify that the amplitude is bigger than the screen height of 8 divisions. Use the POS control to shift the top and bottom of the signal into the screen area. - Press both AMPL keys; this activates the VAR function. Now input sensitivity can be adjusted in fine steps. The message ’VARIABLE ATTENUATION’ is displayed briefly. - Press the lower AMPL key until a readout of 150 mV is reached. - Turn the POS control to position the waveform in the middle of the screen. - Check for a display as indicated in Fig. 3.5. CH... 150mV ↓CH... 150mV MTB 100µs MTB 100µs st6653 Figure 3.5 ST6654 Figure 3.6 INV function: - The following check is only required for CH2 and CH4. - Press the INV key and check for a display as shown in Fig. 3.6. AUTO RANGE function: - The AUTO RANGE function automatically selects the input sensitivity to the best possible amplitude of an input signal. - Press the AUTOSET key. Verify that a stable signal is displayed. - Press the upper AMPL key and select 20.0 mV/div. The signal amplitude is bigger now than the 8 divisions screen height. - Press the channel’s AUTO RANGE key and check that the input signal is again visible with an amplitude between 2 and 6.4 divisions. - Press the lower AMPL key and select 2.00 V/div. The signal amplitude is very small and it may be that the instrument is not triggered. - Press the channel’s AUTO RANGE key and check that the input signal is again visible with an amplitude between 1.2 and 6.4 divisions. BRIEF CHECKING PROCEDURE 3-7 TRIG VIEW channel and EXT TRIG in PM3370B, PM3380B or PM3390B: - Connect a probe to the EXT TRIG input and PROBE ADJUST. - Press the EXT TRIG key. - Press the TRIG VIEW key. Switch CH1 or CH2 off if they are on. - Adjust the AMPL key in the EXT TRIG section to an input sensitivity of 1.00V. - Check for a display as shown in fig. 3.7. - Press the EXT TRIG key and check that the displayed square-wave starts with a negative-going slope. - Press the EXT TRIG key and check that the display as shown in fig. 3.7. is obtained again. - Press the AC/DC key in the EXT TRIG section so that dc input coupling (=) is obtained. - Check for a display as shown in fig. 3.8. - Press the ANALOG key to switch the instrument back to analog mode ("ANALOG MODE’ appears briefly). - CH... 1.00V CH... 1.00V MTB 100µs Figure 3.7 MTB 100µs ST6652 ST6650 Figure 3.8 3-8 BRIEF CHECKING PROCEDURE 3.4 Horizontal section, MAIN TB and DELAYED TIME BASE. Preparation: - Connect a probe to the CH1 input. - Connect the probe tip to the Probe Adjust output socket. - Press the AUTOSET key. - Adjust the AMPL keys to an input sensitivity of 100mV/div. - Adjust the MAIN TB TIME/DIV keys to 100 µs/div. - Verify that a square-wave as shown in Fig. 3.3 is displayed. MTB trigger slope: - Press the TRIG 1 key and verify that the displayed square-wave starts with a negative-going signal. - Press the TRIG 1 key again and verify that the displayed square-wave starts with a positive-going slope as indicated in Fig. 3.3. Time coeficients MAIN TB and VAR in analog mode: - Press the left of the MAIN TB TIME/DIV keys and verify that the number of signal periods increases. - Select 500 µs/division and verify that one signal period is displayed per division. - Press both MAIN TB TIME/DIV keys: this activates the VAR mode. The message ’VARIABLE TIMEBASE’ is displayed briefly. - Press the right of the MAIN TB TIME/DIV keys until 250 µs is displayed. - Verify that one signal period occupies 2 divisions. - Press the left of the MAIN TB TIME/DIV keys until 500 µs is displayed. - Verify that one signal period occupies 1 divison. - Press both MAIN TB TIME/DIV keys: the VAR mode is switched off. The message ’1-2-5 STEPS’ is displayed briefly. - Press the right of the MAIN TB TIME/DIV keys and verify that the number of signal periods decreases. - Select 100 µs/division with the MAIN TB TIME/DIV keys and verify that the square wave is displayed as shown in Fig. 3.3. MAIN TB and DELAYED TIMEBASE functions: - Press the lower CH1 AMPL key so that an input sensitivity of 200 mV/division is obtained for channel 1. - Use the CH1 POS control to position the signal in the upper half of the screen. - Press the DTB menu key: the DELAYED TIMEBASE menu appears at the CRT softkeys. - Select DEL’D TB ’on’ and MAIN TB ’on’ from this menu. - Use the DELAYED TIMEBASE keys, to select 20.0 µs/division. - Adjust the DELAY control in the DELAYED TIMEBASE section so that the display shown in Fig. 3.9 is obtained. For this the TRACK control must be adjusted so that MAIN TB is above the DEL’D TB display. BRIEF CHECKING PROCEDURE - - - 3-9 Press the left of the DELAYED TIMEBASE TIME/DIV keys and verify that the number of the displayed signal periods increases. The lowest TIME/DIV range is 100 µs/division. Press the right of the DELAYED TIME BASE TIME/DIV keys and verify that the number of displayed periods increases. Proceed until the time scale of 50.0 µs/division is reached. Select ’trig’d’ from the DELAYED TIME BASE menu. Press the front panel key TRIG1 if the DELAYED TIMEBASE is not triggered on CH1. This is indicated in the lower right corner of the display. Use the ∆ control to adjust the trigger level of DELAYED TIMEBASE for a triggered display (signal on DEL’D TB time scale visible). MAIN TB DISPLAY TRACK DELAY TB DISPLAY CH1 0.2V MTB ... DTB ... 400µs POS ST6655 Figure 3.9 MAIN TB trigger slope and time coeficients in digital mode: - Press the ANALOG key (’DIGITAL MODE’ is displayed briefly). The oscilloscope is now in digital mode. - Press the AUTOSET key. - Adjust the AMPL keys to an input sensitivity of 100 mV/division. - Adjust the MAIN TB TIME/DIV keys to 100 µs/DIV. - Press the TRIG1 key and verify that the displayed square wave starts with a negative going signal. - Press the TRIG1 key and triggering on the positive slope is obtained again. - Press the left side of the MAIN TB TIME/DIV keys and verify that the number of signal periods increases. - Select 500 µs/division and verify that one signal period is displayed per division. - Press the right side of the MAIN TB TIME/DIV keys and verify that the number of signal periods decreases. - Use the MAIN TB TIME/DIV to select 20.0 µs/division. 3 - 10 BRIEF CHECKING PROCEDURE AUTO RANGE function: - The AUTO RANGE function of the main time base (MAIN TB) adjusts the time base automatically so that 2 to 6 waveform periods are displayed. - Press the AUTO RANGE key in the time base section. - Check that the time base is readjusted so that 2 to 6 waveform periods are displayed. - Press the left of the MAIN TB TIME/DIV keys until MTB 2.00ms is displayed. - Press the AUTO RANGE key in the time base section. - Check that the time base is readjusted so that 2 to 6 waveform periods are displayed. - Press the AUTO RANGE key in the time base section. - Adjust MAIN TB TIME/DIV to 100µs/div. MAIN TB and DELAYED TIMEBASE functions: - Press the lower CH1 AMPL key so that an input sensitivity of 200 mV/division is obtained for channel 1. - Use the CH1 POS control to position the signal in the upper half of the screen. - Press the DTB menu key, the DELAYED TIME-BASE menu appears above the CRT softkeys. - Select DEL’D TB ’on’ and MAIN TB ’on’ front from the DELAYED TIMEBASE menu. - Use the DEL’D TB TIME/DIV to select 20.0 µs/division. - Adjust the DELAY control in the DELAYED TIME BASE section so that the display of Fig. 3.9 is obtained. To do this the TRACK control must be adjusted such that MAIN TB is above the DEL’D TB display. - Press the left side of the DELAYED TIME BASE TIME/DIV keys and verify that the number of displayed signal periods increases. The lowest TIME/DIV range is 100 µs/division. - Press the right side of the DELAYED TIME BASE TIME/DIV keys and verify that the number of displayed periods increases. Proceed until the time scale of 50.0 µs/division is reached. - Select ’trig’d’ from the DELAYED TIME BASE menu. Press the front panel key TRIG1 if the DELAYED TIMEBASE is not triggered on CH1. This is indicated in the lower right corner of the display. Use the ∆ control to adjust the trigger level of DELAYED TIMEBASE for a triggered display. The signal on the DEL’D TB time scale is visible. Press the ANALOG key to switch the instrument back to analog mode (’ANALOG MODE’ is displayed briefly. BRIEF CHECKING PROCEDURE 3 - 11 3.5 Horizontal section, X-deflection. Preparation: - Connect a probe to the CH1 input. - Connect the probe tip to the Probe Adjust output socket. - Press the AUTOSET key. - Press the AMPL keys to adjust to an input sensitivity of 100mV/div. - Press the MAIN TB TIME/DIV keys to adjust to 100 µs/div. - Verify that a square wave as shown in fig. 3.3 is displayed. X-defection check: - Press the CH2 ON key to turn CH2 on. - Press the CH1 ON key to turn CH1 off. - Press the DISPLAY menu key. - Press the X-DEFL softkey in the DISPLAY menu. - Select ’on’ and ’ch1’ as X-SOURCE in the X-DEFL menu. - Verify that two points with a horizontal distance of approximately 6 divisions are displayed. 3.6 Cursors Preparation: - Connect a probe to the CH1 input. - Connect the probe tip to the Probe Adjust output socket. - Press the AUTOSET key. - Adjust the CH1 AMPL key pair to obtain an input sensitivity of 100mV/div. - Adjust the MAIN TB TIME/DIV keys to100 µs/div. - Verify that a square wave with an amplitude of 6 divisions is displayed. VOLT cursors check: - Press the CURSORS menu key; the CURSORS menu appears at the CRT softkeys. - Use the softkeys to select ’on’ and volt cursors (=). - Verify that a dashed and a dotted horizontal line (the volt cursors) appear on the screen. - Press the READOUT softkey and select ∆ V from the menu. - Press softkey RETURN. - Use the TRACK control to position the dashed line exactly on the bottom level of the waveform. - Use the ∆ control to position the dotted line exactly on the top level of the waveform as shown in figure 3.10. - Check for a volt cursor readout of approximately 600 mV in the top of the display area. 3 - 12 - BRIEF CHECKING PROCEDURE Press the ANALOG key (’DIGITAL MODE’ is displayed briefly). The oscilloscope is now in digital mode. Verify that the cursors are on the top and bottom of the waveform. If necessary, readjust them using the TRACK and ∆ controls. Check for a volt cursor readout of approximately 600 mV in the top of the display area. CURSORS on off # ch1 ch2 ch4 ∆ ch1: ∆V=600mV ∆V READOUT TRACK CH1 100mV ST6656 9303 MTB= 0.1ms 100µs Figure 3.10 CURSORS on off # ch1 ch2 ch4 ch1: ∆T=500µs ∆T READOUT CH1 100mV TRACK Figure 3.11 MTB= 0.1ms 100µs ∆ ST6657 9303 BRIEF CHECKING PROCEDURE 3 - 13 TIME cursors check: - Using a softkey, select time cursors (//). - Press the READOUT softkey and select ∆T from the menu. - Press the RETURN softkey. - Turn the ∆ control so that the dotted line is approximately 2 divisions to the right of the dashed line. - Turn the TRACK control so that the dashed line coincides exactly with the first negative edge of the signal. - Turn the ∆ control so that the dotted line coincides exactly with the second negative edge of the signal. - Check for a time cursor readout of approximately 500 µs in the top of the display area. - Press the ANALOG key (’ANALOG MODE’ is displayed briefly). The oscilloscope is now in analog mode. - Verify that the cursors are on the first and second negative slope of the waveform. If necessary readjust them using the TRACK and ∆ controls. - Check for a time cursor readout of approximately 500 µs in the top of the display area. 3.7 TEXT OFF key: - Press the TEXT OFF key and verify that the CRT softkey text disappears. Press the TEXT OFF key again and verify that only the signal, the cursors, and the cursor readout value are displayed. Press the TEXT OFF key to obtain full information again in the viewing area. PERFORMANCE TEST 4-1 4 PERFORMANCE TEST 4.1 GENERAL INFORMATION WARNING: Before turning on the instrument, ensure that it has been installed in accordance with the Installation Instructions, outlined in Section 2 of the Operation Guide. This procedure is intended to: - Check the instrument’s specification. Be used for incoming inspection to determine the acceptability of newly purchased instruments and/or recently recalibrated instruments. Check the necessity of recalibration after the specified recalibration intervals. NOTE: The procedure does not check every facet of the instrument’s calibration; rather, it is concerned primarily with those parts of the instrument which are essential to measurement accuracy and correct operation. Removing the instrument covers is not necessary to perform this procedure. All tests are made from the outside of the instrument. If the test is started shortly after turning on the instrument, steps may be out of specification, due to insufficient warm up time. Be sure to allow the full warm up time of 35 minutes (under average conditions). The tests are made with a stable, well-focused, low-intensity display. Unless otherwise noted, adjust the intensity, position, and trigger level controls as needed. IMPORTANT NOTES - - The input voltage must be supplied to the CH1 input, unless otherwise stated. Set the MAIN TB TIME/div key pair to a suitable position, unless otherwise stated. Tolerances given are for the instrument under test and do not include test equipment error. Bear in mind that the test equipment and connecting cables are properly terminated. In case of high-frequency signals, this termination must be 50Ω. This is achieved with a 50Ω termination at the end of the cable. Such termination is not necessary for the PM3394B (all channels), or CH1, CH2 of the PM3390B; these oscilloscopes feature switchable internal 50Ω input impedance. 4-2 - - - - PERFORMANCE TEST In some tests vertical channels CH2, CH3, CH4 appear in parentheses after CH1, e.g., CH1 (CH2, CH3, CH4). This indicates that the CH1 test should be performed first, followed by the tests for CH2, CH3 and CH4. Some of the tests are not necessary for all five oscilloscope types. An example are the channels CH3, CH4 that are not present in PM3370B/80B/90B. This is indicated as necessary. The test step may then be skipped. Where required, tests are done in either analog or digital mode. Switching between analog and digital mode is done by pressing the ANALOG key. When you enter either analog or digital mode, the display indicates ’ANALOG MODE’ or ’DIGITAL MODE’ briefly. Test steps where the use of a 10:1 probe is mentioned, must be done with the probe type such as delivered with the oscilloscope. The test set-up figures in this section are universal: they indicate the most extensive 4 channel instrument. For PM3370B/80B/90B, the CH3 input is not present and the CH4 input socket is an EXTernal TRIGger input. 4.2 RECOMMENDED TEST EQUIPMENT Note: Note: The FLUKE 5500A has to be equipped with the SCOPE option and is always used in SCOPE mode (SCOPE button active). The digital multimeter and oscilloscope are not required for this test. they are used for corrective maintenance. Type of instrument Required specification Example of recommended instrument Function generator Freq: 10 Hz...100 kHz Sine /square-wave Ampl: 1.8mV...55V (pp) FLUKE 5500A mode: wavegen Constant amplitude sine wave generator Freq: 50kHz...300 MHz Constant pp. amplitude of 5mV to 5.5V. FLUKE 5500A mode: levsine Square-wave calibration generator For ampl. calibration: Freq: 10 Hz...10kHz Ampl: 1.8 mV...2.2V pp For rise time measurements: Freq: 1kHz...1MHz Ampl: 4.5mV...2.75V FLUKE 5500A mode: volt FLUKE 5500A mode: edge PERFORMANCE TEST 4-3 Time marker generator Repetition rate: 5 sec...2 nsec FLUKE 5500A mode: marker Digital multimeter Wide voltage and current ranges. Fluke 29 / 79 with AC, DC and resistance ranges. High voltage probe. Required: 1% accuracy, model 80K40 Variable voltage transformer (VARIAC) Well insulated output voltage 90...264V TV pattern generator with video output Oscilloscope The bandwidth must PM3394B be the same or higher than the bandwidth of the instrument under test. 50Ω cables, 75Ω cables, 50Ω termination, Tektronix and Fluke BNC PM9074 types for fast rise time PM9075 square-wave, high PM9585 (1W), PM9581 (3W) frequency sine wave and TEK 011-0055-01 other applications. TEK 011-0059-02 TEK 011-0069-02 PM9067 PM9584/02 75Ω termination, 10:1 attenuator, 2:1 attenuator, T-piece, power splitter Fluke PM5418 4-4 PERFORMANCE TEST 4.3 TEST PROCEDURE 4.3.1 Preliminary settings Test equipment: None Settings/procedure and requirements: 1 - 2 3 - 4 5 6 - 7 8 9 - If not present install 2 penlight (LR6) back up batteries in the holder at the rear panel of the oscilloscope. Turn on the oscilloscope under test. Press the STATUS and TEXT OFF keys simultaneously. This assures that the oscilloscope follows the default reaction when the green AUTOSET key is pressed. You can verify that the oscilloscope is in analog mode by pressing the RUN/STOP key. If you are in analog mode, the message ’PLEASE FIRST SWITCH TO DSO’ is displayed. The now following steps are applicable for PM3390B and PM3394B. Press the UTILITY menu key to display the UTILITY menu. Press softkey AUTOSET to display the UTILITY AUTOSET menu. Press the relevant softkey to put the oscilloscope in the ’userprog’ mode; the text ’userprog’ must be intensified. Press softkey VERT. Select with softkey ’1MΩ / 50Ω / unaffect’ the ’unaffect’ position. Check for the instrument settings in the lower part of the viewing area: when not available press TEXT OFF until the maximum amount of information is displayed. PERFORMANCE TEST 4.3.2 4-5 Power supply This test checks the proper operation of the power supply at all possible line voltages. Test equipment: Variable voltage transformer (VARIAC) Test set-up: VARIAC OSCILLOSCOPE UNDER TEST OUTPUT Probe Adjust TO MAINS OSC POWER CORD CH1 PROBE CH2 CH3 CH4 MAT4127 9303 Settings/procedure: 1 - 2 3 - 4 - Adjust the input line voltage to the oscilloscope (output from VARIAC) to a desired value between 100 and 240V (rms), frequency 50...400 Hz. Press POWER ON on the oscilloscope. Apply the Probe Adjust signal from the front panel of the oscilloscope to input CH1, e.g., by means of a 10:1 probe. Press the green AUTOSET key. Requirements: 1 - 2 - 3 - 4 - Verify that the oscilloscope starts at any input voltage between 100 and 240V; in particular the line voltages 100, 120, 220 and 240V must be checked. Verify that the instrument’s performance does not change over the indicated voltage range; and that the displayed Probe Adjust signal is distortion-free and has equal intensity. Press the ANALOG key (’DIGITAL MODE’ is displayed briefly), and verify that the instrument’s performance does not change in digital mode at the indicated line voltages (100, 120, 220 and 240V). The displayed Probe Adjust signal must be free from distortion. Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to switch to analog mode. 4-6 4.3.3 PERFORMANCE TEST Auto set This test checks the correct working of the AUTOSET function. Test equipment: Fluke 5500A mode levsine (Alternative: Constant amplitude sine wave generator SG 503). Test set-up: Settings/procedure: 1 2 - Apply a 10 MHz sine wave signal of 600 mV (pp into 50Ω) to input CH1;. Press the green AUTOSET key. Use a 50Ω termination at the end of the coax cable. For instruments with switchable 50Ω input impedance (attainable via VERT MENU key) it is recommended to use the internal termination (when active, the text ’LZ’ appears in the lower part of the viewing area). For instruments without internal termination, an external termination should be used. Requirements: 1 - 2 - 3 - 4 - Verify that the displayed waveform is stable and properly triggered. Amplitude should be within the screen area. Horizontally some signal periods should be displayed. Repeat the same settings and procedure for CH2, CH3 and CH4. For PM3370B/80B/90B: check CH2 and input EXT TRIG. Press the ANALOG key to return to digital mode. The message ’DIGITAL MODE’ appears briefly. Repeat the AUTOSET check in the digital mode for CH2, CH3, and CH4. For PM3370B/80B/90B: check CH2 and input EXT TRIG. PERFORMANCE TEST 4.3.4 4-7 Orthogonality This test checks the angle between the horizontal and vertical deflection plates (orthogonality). Test equipment: Fluke 5500A mode wavegen, wave sine (Alternative: function generator PM5136). Test set up: Settings/procedure: 1 - 2 3 - 4 - 5 - 6 7 8 9 - Press the CAL key for a few seconds to start the autocal procedure. This takes approximately 4 minutes. When ready, the oscilloscope is fine tuned to optimal accuracy. Apply a 50 Hz sine wave signal of 8V (pp) to input CH1; Press the AUTOSET key and adjust the input signal to a trace- height of 8 div (CH1 in 1V/div). Activate the GND function and verify that the straight line is exactly parallel to the horizontal graticule lines. If not, readjust the TRACE ROTATION. Switch the GND function off and verify that a signal of 8 divisions is displayed. Press the DISPLAY menu key. Press the X-DEFL softkey. Select ’on’ and ’ch2’ from the X-DEFL menu. Use the X POS control to move the vertical line to the center of the screen. 4-8 PERFORMANCE TEST Requirements: 1 - 2 - Verify that the vertical line is parallel to the vertical graticule line in the center of the screen. Verify that the angle with respect to the horizontal graticule lines is 90° ± 0.5° as indicated in the figure. ≤ 0.07div ≤ 0.07div OR MAT3913 Figure 4.1 4.3.5 Orthogonality Trace distortion This test checks the distortion of a horizontal line in the central 6 x 8 divisions of the screen. Test equipment: None Settings/procedure: 1 2 - Press the AUTOSET key with no input signal applied to the scope. Use the CH1 POS control to shift the timebase line vertically across the center 6 divisions of the screen. Requirements: - Verify that the deviation from the ideal straight line does not exceed 0.03 divisions in the center of screen and 0.1 divisions elsewhere. Test equipment: Fluke 5500A mode: wavegen, wave sine (Alternative: function generator PM5136). PERFORMANCE TEST 4-9 Test set-up: Settings/procedure: 1 2 - 3 - 6 7 8 9 - Apply a 50 Hz sine wave signal of 8V (pp) to input CH1; Press the AUTOSET key and adjust the input signal to an amplitude of 8 divisions (CH1 in 1V/div). Using the CH1 POS control, adjust the display around the center of the screen. Press the DISPLAY menu key. Press the X-DEFL softkey. Select ’on’ and ’ch2’ from the X-DEFL menu. Use the X POS control to shift the vertical line across the middle eight divisions of the screen. Requirements: - Verify that the deviation from the ideal straight line does not exceed 0.03 divisions in the center of screen and 0.1 divisions elsewhere. 4.3.6 Vertical deflection; deflection coefficients The vertical deflection coefficients of channels CH1, CH2, CH3, and CH4 are checked by means of a calibrated signal. PM3370B/80B/90B: the channels CH1, CH2 and TRIG VIEW via input EXT TRIG are checked. Test equipment: Fluke 5500A mode: volt (Alternative: Square-wave calibration generator PG 506). 4 - 10 PERFORMANCE TEST Test set up: Settings/procedure: 1 - 2 3 - 4 5 6 7 8 - Note: Apply a 1 kHz square-wave signal of 30 mV to input CH1. Set the generator in ’volt’ mode. The generator must not be terminated with 50Ω (the text ’LZ’ must not be visible in the lower part of the viewing area). Press the green AUTOSET key. Set CH1 to 5 mV/div and to DC input coupling. The waveform must be in the vertical middle of the screen. Press the ACQUIRE menu key. Select BW LIMIT ’on’ from the VERT MENU key. Press the TRIGGER menu key. Select noise ’on’ and ’hf-rej’ from the TRIGGER MAIN TB menu. Change the input voltage and the setting of CH1 according to table I and verify that the amplitude of the signal agrees with this table. The signal should remain positioned in the vertical center of the screen. Only the input sensitivities essential for input accuracy are checked. Requirements: table I. Input voltage (pp) Setting Requirements analog mode Requirements digital mode 30 mV 60 mV 1.2V 6V 5 mV 10 mV 0.2V 1V 5.92...6.08 div (±1.3%) 5.92...6.08 div (±1.3%) 5.92...6.08 div (±1.3%) 5.92...6.08 div (±1.3%) 5.88...6.12 div (±2%) 5.88...6.12 div (±2%) 5.88...6.12 div (±2%) 5.88...6.12 div (±2%) PERFORMANCE TEST 4 - 11 Repeat the settings/procedure in table I for CH2, CH3 and CH4. Use table II for PM3370B/80B/90B to test TRIG VIEW via input EXT TRIG. Select AC input coupling to center the trace on the screen. table II. Input voltage (pp) Setting Requirements analog mode Requirements digital mode 0.6V 6V 0.1V 1V 5.82...6.18 div (±3%) 5.82...6.18 div (±3%) 5.82...6.18 (±3%) 5.82...6.18 (±3%) - Press the ANALOG key (’DIGITAL MODE’ is displayed briefly), and repeat the tests in this chapter for the digital mode. Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. 4.3.7 Vertical deflection; variable gain control range (continuation of 4.3.6) This test checks the vertical VARiable gain control. Settings/procedure: 1 2 - 3 - 4 - Apply a square-wave signal of 0.2V to input CH1 and press AUTOSET. Set CH1 to 50 mV/div and input coupling to DC. Using the CH1 POS control, center the waveform in the screen. Select the VARiable mode by simultaneously pressing both AMPL keys. The readout changes into 50.0 mV/div. Press the mV key to adjust an input sensitivity of 40.0 mV/div. Requirements: 1 - 2 - 4.3.8 Verify that the displayed amplitude is between 4.86 and 5.14 divisions (+/- 2.8%). Repeat the settings and procedure for CH2. For the PM3394B and PM3384B repeat the same steps for CH3 and CH4. Vertical deflection; input coupling (continuation of 4.3.7) This test verifies the operation of the AC input coupling. Also, the operation of the ground (GND) function is checked. 4 - 12 PERFORMANCE TEST Settings/procedure: 1 - 2 - Switch the CH1 VARiable mode off by simultaneously pressing both AMPL/VAR keys. The readout changes to 50 mV. CH1 sensitivity is 50 mV/div; the vertical deflection is now 4 divisions. Requirements: 1 - 2 - 3 - Activate the CH1 GND function and verify that a horizontal line is displayed. Select the AC input coupling and verify that a 4 divisions square-wave signal is displayed. Center this signal in the middle of the screen. Select the DC input coupling and verify that the 4 divisions square-wave signal moves up. This shift is caused by the signal’s positive dc component: this component is not blocked in DC coupled mode. Repeat the settings and procedure for CH2, CH3, and CH4. PM3370B/80B/90B: check CH2 and TRIG VIEW via EXT TRIG input for AC and DC coupling. 4.3.9 Vertical cursor accuracy (continuation of 4.3.8.) This test verifies the accuracy of the voltage cursors Settings/procedure: 1 2 3 4 5 6 - 7 8 9 - Change the generator output voltage to 0.1V. Apply this voltage to CH1. Switch CH1 to ON, and switch the other channels off. Select DC coupled input and 20 mV/division for CH1. Select CH1 as trigger source (TRIG 1). Use the POS control to center the 5 division square wave on the dotted horizontal lines of the graticule. Press the CURSORS menu key. Select ’on’ and volt cursors (=) from in the CURSORS menu. Select ∆ V from the READOUT menu. Requirements: 1 - 2 - 3 - Use the TRACK and ∆ controls to position both cursor lines exactly on top and bottom of the signal. Check for a cursor readout between 98.4 and 101.6 mV. Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) and repeat the check in this chapter for the digital mode. Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. PERFORMANCE TEST 4.3.10 4 - 13 Vertical deflection; high-frequency response This test verifies the upper transition point of the vertical bandwidth. Test equipment: Fluke 5500A mode: levsine (Alternative: constant amplitude sine wave generator SG 503). Test set-up: Settings/procedure: 1 - 2 - 3 4 5 - 6 8 9 - 10 - Apply a 50 kHz sine wave signal of 600 mV (pp into 50Ω) to input CH1, and press the AUTOSET key. Use an external 50Ω termination. Use the internal termination of the oscilloscope, when available (if active, the text ’LZ’ is visible in the lower part of the viewing area). Internal 50Ω termination is attainable via the VERT MENU key (PM3390B/94B). Set CH1 to 0.1V/div. Adjust the input signal to an amplitude of exactly 6 divisions. Slowly increase the frequency to 200 MHz (PM3390B, PM3394B), 100 MHz (PM3384B, PM3380B) or 60 MHz (PM3370B) and verify that the displayed amplitude does not drop below 4.2 divisions. Switch the frequency of the sine wave signal back to 50 kHz. Press the ACQUIRE menu key. Select BW LIMIT ’on’ via the VERT MENU key. Slowly increase the frequency to 20 MHz and verify that the vertical deflection has decreased to 4.2 div approximately at 20 MHz. Switch the bandwidth limiter to ’off’. 4 - 14 PERFORMANCE TEST Requirements: - The vertical deflection must be 4.2 divisions or more. For the bandwidth limiter the requirement is 4.2 div approximately at 20 MHz. Repeat the above settings and procedure for CH2, CH3 and CH4. PM3370B/80B/ 90B: check CH2 and TRIG VIEW via EXT TRIG input. Oscilloscope in 1V/div and generator voltage 5 Vpp into 50Ω. Termination resistor directly at generator output. Use a BNC / probe tip adapter between termination and 10:1 probe. Adjust the amplitude at 50 kHz to 5 divisions. Check that the amplitude at higher frequencies does not drop below 3.5 div. - Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) and repeat the tests in this section for the digital mode. Adjust the MAIN TB TIME/DIV if required. 4.3.11 Vertical deflection; low-frequency response This test verifies the lower transition point of the vertical bandwidth. Test equipment: Fluke 5500A mode: wavegen, wave sine (Alternative: function generator PM5136). Test set up: PERFORMANCE TEST 4 - 15 Settings/procedure: 1 - 2 3 4 - Apply a 5 kHz sine wave signal of 600 mV (pp into 50Ω) to input CH1, and press the AUTOSET key. Set CH1 to 0.1V/div. Adjust the input signal to an amplitude of exactly 6 divisions. Lower the frequency to 10 Hz and verify that the displayed amplitude does not drop below 4.2 divisions. Requirements: - The vertical deflection must be 4.2 divisions or more. Repeat the above settings and procedure for CH2, CH3, and CH4. PM3370B/ 80B/90B: check CH2 and TRIG VIEW via EXT TRIG input. - Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. 4.3.12 Vertical deflection; dynamic range at 15/25/50 MHz The oscilloscope must be capable of displaying signal amplitudes that are larger than the screen. In practice, a low frequency signal with an amplitude equivalent to 24 divisions must be displayed with no distortion. Test equipment: Fluke 5500A mode: levsine (Alternative: constant amplitude sine wave generator SG 503). Test set up: 4 - 16 PERFORMANCE TEST Settings/procedure: 1 - 2 3 4 - Apply a 50 MHz (PM3390B/94B), 25 MHz (PM3380B/84B) or 15 MHz (PM3370B) sine wave signal of 2.4 V(pp into 50Ω) to input CH1 and press the AUTOSET key. Use a 50Ω termination. Use the internal termination when avaialble. Set CH1 to 0.1V/div. Using the CH1 POS control, shift the sine wave vertically over the screen. Requirements: - Verify that top and bottom of the sine-wave signal of 24 divisions in amplitude can be displayed with no distortion. Repeat the above settings and procedure for CH2, CH3, and CH4. PM3370B/ 80B/90B: check CH2. 4.3.13 Vertical deflection; dynamic range at 60/100/200 MHz (continuation of 4.3.12) In this test, the dynamic range of the amplifier is checked at a high frequency. Settings/procedure: 1 - 2 3 4 - Apply a 200 MHz (PM3390B/94B), 100 MHz (PM3380B/84B) or 60 MHz (PM3370B) sine-wave signal of 0.8 V(pp into 50Ω) to input CH1. Press the AUTOSET key, and set CH1 to 0.1V/div. Use a 50Ω termination. Use the internal termination when available. Set the amplitude to exactly 8 divisions. Requirements: - Verify that the sine wave of 8 divisions in amplitude is displayed with no distortion. Repeat the above settings and procedure for CH2, CH3, and CH4. PM3370B/80B/90B: check CH2. 4.3.14 Vertical deflection; position range The range of the vertical shift is checked with a sine-wave signal of 8 divisions in amplitude. Test equipment Fluke 5500A mode: wavegen, wave sine (Alternative function generator PM5136). PERFORMANCE TEST 4 - 17 Test set up: Settings/procedure: 1 - 2 3 - Apply a 1 kHz sine wave signal with an amplitude of 0.8 V (pp) to input CH1. Press the AUTOSET key and set CH1 to 0.1V/div. Adjust the generator so that the displayed amplitude is exactly 8 divisions. Requirements - Turn the CH1 POS control fully clockwise and counterclockwise and verify that top and bottom of the 8 divisions signal can be positioned outside the graticule. Repeat the above settings and procedure for CH2, CH3, and CH4. PM3370B/80B/90B: check CH2. 4.3.15 Vertical deflection; crosstalk between channels at 60/100/200 MHz At higher frequencies there exists some crosstalk between any two channels. In the following test, crosstalk is verified at a high frequency. Test equipment: Fluke 5500A mode: levsine (Alternative constant amplitude sine wave generator SG 503). 4 - 18 PERFORMANCE TEST Test set up: Settings/procedure: 1 - 2 3 4 5 6 7 - Apply a 200 MHz (PM3390B/94B), 100 MHz (PM3380B/84B) or 60 MHz (PM3370B) sine-wave signal of 0.8 V(pp into 50Ω) to input CH1. Press the AUTOSET key. Use a 50Ω termination. Use the internal termination when available. Switch all channels ON. PM3370B/80B/90B: switch CH2 on. Set all channels to 0.1 V/div. Adjust the generator to a signal amplitude of 8 div. Activate the GND function of CH2, CH3, and CH4. PM3370B/80B/90B: activate GND of CH2. Requirements: - Verify that the displayed amplitude the channels with no input signal applied is less than 0.16 divisions, (better than 50:1). Repeat the above settings and procedure for PM3384B/94B: - Input signal applied to CH2. CH1, CH3, and CH4 input GND. - Input signal applied to CH3. CH1, CH2, and CH4 input GND. - Input signal applied to CH4. CH1, CH2, and CH3 input GND. Repeat the above settings and procedures for PM3370B/80B/90B: - Input signal applied to CH2. CH1 input GND. For all models: - Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) and repeat the tests in this chapter for the digital mode. - Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. PERFORMANCE TEST 4.3.16 4 - 19 Vertical deflection; common mode rejection ratio at 1 MHz The common mode rejection ratio (CMRR) is a measure of susceptibility to common mode signals. This susceptibility is verified in this test. Test equipment: Fluke 5500A mode: levsine (Alternative: HF constant amplitude sine wave generator SG 503). Power splitter Test set up: Settings/procedure: 1 - 2 3 - 4 - 5 6 7 8 - 9 - Use a power splitter and two cables of equal length to CH1 and CH2. Apply a 2 MHz sine-wave signal of 1.6 V(pp into 50Ω) to inputs CH1 and CH2. Press the AUTOSET key. Use 50Ω terminations. Use the internal terminations when available (via VERT MENU key). Set CH1 and CH2 to 0.1V/div and adjust the generator voltage for a deflection of 8 divisions. Set CH1 and CH2 to DC input coupling. Press the CH1+CH2 key to activate the ‘added’ mode. Press the INV key of CH2; the result is the display of CH1-CH2. Press the ON keys of CH1 and CH2; this switches CH1 and CH2 off and only the differential signal (CH1 CH2) is now visible. Readjust the VAR function of CH1 or CH2 for minimum amplitude. Requirements - Verify that the trace-height of the CH1-CH2 differential signal is less than 0.08 divisions. Repeat the above settings and procedure for CH3 and CH4 (for PM3384B and PM3394B only). 4 - 20 4.3.17 PERFORMANCE TEST Vertical deflection; common mode rejection ratio at 50 MHz (continuation of 4.3.16) The common mode rejection ratio (CMRR) indicates the susceptibility to common mode signals at higher frequencies. The susceptibility is verified in this test. Settings/procedure: 1 - 2 3 4 - 5 6 7 - 8 - 9 - Use a power splitter and two cables of equal length to CH1 and CH2. Apply a sine-wave signal of 50 MHz with an amplitude of 0.6 V(pp into 50Ω) to inputs CH1 and CH2. Press the AUTOSET key. Use a 50Ω termination. Use the internal termination when available. Set CH1 and CH2 to 0.1 V/div and adjust the generator voltage for a deflection of 6 divisions. Set CH1 and CH2 to DC input coupling. Press the CH1+CH2 key; to activate the added mode. Press the INV key of CH2; the result is the display of the differential signal of CH1-CH2. Press the ON keys of CH1 and CH2; this switches CH1 and CH2 off and only the differential signal of CH1 CH2 display is now visible. Readjust the VAR function of CH1 or CH2 for minimum amplitude. Requirements: - Verify that the amplitude of the CH1-CH2 differential signal is less than 0.24 divisions. - Repeat the above settings and procedure for CH3 and CH4 (for PM3384B and PM3394B only). 4.3.18 Vertical deflection; LF linearity The linearity of the vertical amplifier is checked by moving a signal with a fixed amplitude vertically over the entire screen area. Test equipment Fluke 5500A mode: wavegen, wagve square (Alternative: function generator PM5136). PERFORMANCE TEST 4 - 21 Test set up: Settings/procedure 1 2 3 4 - 5 - Apply a 50 kHz square-wave signal of 200 mV(pp into 50Ω)to input CH1. Press the AUTOSET key and set CH1 to 0.1V/div. Move the square-wave signal to the vertical center of the screen. Adjust the generator output so that the displayed amplitude is exactly 2 divisions. Use the CH1 POS control to shift the signal upwards and downwards within the central 6 divisions of the screen. Requirements - Verify that the amplitude of the sq. wave in the central 6 div. screen area is between 1.96 ...2.04 divisions (+ or - 2%). Repeat the above settings and procedure for CH2, CH3 and CH4. PM3370B/80B/90B: repeat this for CH2. Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) and repeat the check in this chapter for the digital mode. The requirement for the digital mode is that the sq. wave amplitude in the central 6 div. screen area is between 1.94 ... 2.06 divisions (+ or 3%). Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. 4 - 22 4.3.19 PERFORMANCE TEST Vertical deflection; visual signal delay Many applications require that the leading edge of a fast pulse triggering the oscilloscope be made visible. A fixed amount of signal delay is introduced in the vertical channels of this instrument to allow the timebase to start before the triggering leading edge causes vertical deflection to occur. This delay is verified in the following test. Test equipment Fluke 5500A mode: edge (Alternative: Square-wave calibration generator PG 506). Test set-up: Settings/procedure: 1 - 2 3 - 4 5 - 6 7 8 - 9 - Apply a signal with a fast rise time of less than 1 ns and an amplitude of 0.5V (into 50Ω), and a frequency of 1 MHz, to input CH1. Press the AUTOSET button and set CH1 to 0.1V/div. Use a 50Ω termination. Use the internal termination when provided (via VERT MENU key). Set the MAIN TB TIME/DIV to 50.0 ns/div. Press the MAGNIFY key and turn the X POS control to display the leading edge. Turn the TRACE INTENSITY control clockwise for maximum intensity. Press the TRIGGER menu key. Select level pp ’off’ and ’dc’ trigger coupling from the TRIGGER MAIN TB menu. Adjust TRIGGER LEVEL for a triggered display and maximum visible signal delay. PERFORMANCE TEST 4 - 23 Requirements - Verify that the visible signal delay is at least 15 ns (3 divisions). MTB 5ns *10 visual signal delay 3div Figure 4.2 4.3.20 MAT4167 Visual signal delay Vertical deflection; base line instability In the following test, several adjustments of balance, offset and jump, are checked. Test equipment None Settings/procedure and requirements: 1 2 - 3 - 4 - 5 - 6 7 - 8 - Press the AUTOSET key (no input signal) and set CH1 to 5V/div. Use the CH1 POS control to position the trace in the vertical middle of the screen. Press both CH1 AMPL keys simultaneously to select the VARiable mode. The readout changes to 5.00V. The input sensitivity can be adjusted now in very fine steps between 2 mV and 12.5V/div. Press the ’V’ key and verify that the base line jump is not more than 0.2 divisions between 5.00V to 12.5V/div. Press the ’mV’ key and verify that the base line jump is not more than 0.2 divisions between 12.5V/div to 5 mV/div. Press the ON keys of CH2 and CH1; CH2 is now on and CH1 is off. Using the CH2 POS control, position the trace in the vertical middle of the screen. Press both CH2 AMPL keys simultaneously to select the VARiable mode. The readout changes to 5.00V. The input sensitivity can be adjusted now in very fine steps between 2 mV and 12.5V/div. 4 - 24 9 - 10 11 - PERFORMANCE TEST Press the ’V’ key and verify that the base line jump is not more than 0.2 divisions between 5.00V to 12.5V/div. Press the ’mV’ key and verify that the base line jump does not 0.2 divisions between 12.5V/div to 5 mV/div. Press the INV key repeatedly and verify that the base line jump is not more than 0.2 divisions. For the PM3394B and PM3384B repeat the above procedure for CH3 and CH4. The CH3 settings are equal to those of CH1; the CH4 settings are equal to CH2. For PM3390B, PM3380B and PM3370B no further steps required. 4.3.21 Delay difference between vertical channels The delay difference between CH1, CH2, CH3, and CH4 is checked here. Test equipment: Fluke 5500A mode: edge (Alternative: Square wave calibration generator PG 506). Power splitter Test set up: Settings/procedure: 1 - 2 3 - 4 - Apply a square-wave signal with a fast rise time of less than 1 ns, and an amplitude of 1V (into 50Ω), with a frequency of 1 MHz, to inputs CH1 and CH2. Use a power splitter and two cables of equal length to CH1 and CH2. Press the AUTOSET key. Use 50Ω terminations. Use the internal terminations when available on both channels (via VERT MENU key). Set CH1 and CH2 to 0.1V/div and input coupling to DC. PERFORMANCE TEST 5 - 6 7 8 9 10 11 - 12 - 4 - 25 Press the MAGNIFY keys and set the MAIN TB TIME/DIV to 2.00 ns/div (PM3390B/94B) or to 5.00 ns/div (PM3370B/80B/84B). Press the TRIGGER menu key. Select level-pp ’off’ and ’dc’ trigger coupling from the related menu. Press the TB MODE menu key. Select ’trig’ from the related menu. Adjust TRIGGER LEVEL for a triggered display of the leading edge. Using the X POS control, position the leading edges of the signals in the horizontal center of the screen. Using both CH1 and CH2 POS controls, adjust the vertical position of each trace between the dotted 0% and 100% lines. The signals appear to be superimposed. Requirements - Verify that the delay difference between the two displayed signals is less than 0.25 ns. This equals 0.13 divisions in PM3390B/94B or 0.05 divisions in PM3370B/80B/84B. DELAY BETWEEN CHANNELS MAT4168 Figure 4.3 Delay difference ≤ 0.13 div in PM3390B/94B or ≤ 0.05 div in PM3370B/80B/84B. Repeat the above settings and procedure for CH3 and CH4 (not necessary for PM3370B/80B/90B). Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) and repeat the tests in this chapter for the digital mode. In digital mode, it is not necessary to activate the MAGNIFY function since the timebase ranges up to 2.00 ns/ division (PM3390B/94B) or 5.00 ns/division (PM3370B/80B/84B). Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. 4 - 26 4.3.22 PERFORMANCE TEST Horizontal deflection; display modes and trace separation The correct working of main timebase (MAIN TB), delayed timebase (DELAYED TIME BASE) and the trace separation is checked. Test equipment: Fluke 5500A mode: wavegen, wave sine (Alternative: function generator, PM5136). Test set-up: Settings/procedure and requirements: 1 2 3 4 5 6 7 8 9 - 10 - 4.3.23 Apply a 2 kHz sine-wave signal of 400 mV(pp into 50Ω) to input CH1. Press the AUTOSET key and set CH1 to 0.1V/div. Adjust the generator signal to a trace height of 4 divisions. Set MAIN TB to 500 µs. Press the DTB menu key. Set DEL’D TB to ’on’ in the DELAYED TIMEBASE menu. Set MAIN TB to ’on’ in the DELAYED TIMEBASE menu. Set the DELAYED TIMEBASE to 50.0 µs. Turn the DELAY control (in the DELAYED TIMEBASE section), and verify that the intensified part can be shifted horizontally along the MAIN TB display. Operate the TRACK control and check that the DEL’D TB and MAIN TB display can be shifted so that they do not cover each other. Horizontal deflection; X deflection The correct working of the X Y mode (X-DEFL ’on’) is tested. Test equipment: Fluke 5500A mode: wavegen, wave sine (Alternative: function generator, PM5136) PERFORMANCE TEST 4 - 27 Test set-up: Settings/procedure: 1 2 3 4 5 6 7 - Apply a 2 kHz sine-wave signal of 800 mV (pp) to input CH1. Press the AUTOSET key and set CH1 to 0.1V/div. Adjust the generator signal to a trace height of 8 divisions. Press the DISPLAY menu key. Press the X-DEFL softkey in the DISPLAY menu. Select ’on’ and ’ch1’ as X-SOURCE in the X-DEFL menu. Use the CH1 POS and X POS controls to obtain the display shown in the figure below. Requirements: - Verify that a line with an angle of 45° is displayed. MAT3837 Figure 4.4 X deflection 4 - 28 4.3.24 PERFORMANCE TEST Horizontal deflection; MAIN TB deflection coefficients The deflection coefficients of the main timebase generator (MAIN TB) are verified by means of a calibration signal. Test equipment: Fluke 5500A mode: marker (Alternative: time marker generator TG 501). Test set-up: Settings/procedure: 1 2 3 - 4 5 6 7 8 9 - Apply a 50.0 ns time marker signal to input CH1. Press the AUTOSET key. Use a 50Ω termination. For instruments with switchable 50Ω input impedance it is recommended to make use of this feature (via VERT MENU key). Press the TRIGGER menu key. Select level-pp ’off’ and ’dc’ from the TRIGGER MAIN TB menu. Press the TB MODE menu key. Select ’trig’ from the TB MODE menu. Adjust the TRIGGER LEVEL control for a correctly triggered display. Verify the deflection coefficients of MAIN TB with MAGNIFY off ( 1) and * MAGNIFY on (*10) according to the requirements in the tables. Use the deflection error facility of the time marker generator. Note: - Error limits must be measured between the 2nd and the 10th graticule line (there are 11 graticule lines). These are the central 8 divisions. - With MAGNIFY on (*10), the central 10 divisions of the expanded 100 divisions of MAIN TB are measured. PERFORMANCE TEST - 4 - 29 Only the timebase positions essential for instrument accuracy are checked. Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) to perform the tests for the digital mode. Press the TEXT OFF key for full visibility of the time marker pulses in the central 8 divisions. Press the ANALOG key (’ANALOG MODE’is displayed briefly) to return to analog mode. 5equirements for analog mode MAGNIFY off (*1): MAIN TB setting Marker pulse Max. error 20.0 ns (PM3390B/94B) 100 ns 500 ns 1.00 µs 5.00 µs 20.0 µs 500 µs 1.00 ms 10.0 ms 20 ns 0.1 µs 0.5 µs 1 µs 5 µs 20 µs 0.5 ms 1 ms 10 ms 1.8% 1.8% 1.8% 1.8% 1.8% 1.8% 1.8% 1.8% 1.8% Requirements for analog mode MAGNIFY on (*10): MAIN TB setting Marker pulse Max. error 2.00 ns (PM3390B/94B) 5.00 ns 10.0 ns 100 ns 2 ns 5 ns 10 ns 0.1 µs 3.3% 3.3% 2.3% 2.3% Requirements for digital mode: MAIN TB settingMarker pulseMax. error 2.00 ns (PM3390B/94B) 5.00 ns 250 ns 500 ns 20.0 ms 1.00 s 2 ns 5 ns 0.5 µs 0.5 µs 20 ms 1s 1.8% 1.8% 1.3% 1.3% 1.3% 1.3% Check for an undistorted display of the time marker pulses. Timing accuracy should not show a noticeable error. In the MAIN TB setting 250 ns/division, the interval between successive time marker pulses should be 2 div.‘ 4 - 30 4.3.25 PERFORMANCE TEST Horizontal deflection; VARiable mode accuracy MAIN TB. The horizontal MAIN TB deflection coefficients can be varied in steps such as done in 4.3.24. A range of much finer steps can also be selected. Here, the accuracy of this range is checked. Test equipment: Fluke 5500A mode: marker (Alternative time marker generator TG 501). Test set-up: Settings/procedure: 1 2 3 - 4 5 - 6 7 8 - 9 - Apply a 5 us time marker signal to input CH1. Press the AUTOSET key. Use a 50Ω termination. For instruments with switchable 50Ω input impedance it is recommended to make use of this feature. Press the TRIGGER menu key. Select level-pp ’off’ and trigger coupling ’dc’ from the TRIGGER MAIN TB menu. Adjust the TRIGGER LEVEL control for a correctly triggered display. Set the MAIN TB TIME/DIV to 5.00 us. Select the MTB VARiable mode by pressing both MAIN TB TIME/DIV keys at a time: the message; ’VARIABLE TIMEBASE’ is displayed briefly. Press the ’ns’ key and adjust the readout to 2.50 us. Requirements: - Verify that the horizontal distance between the time markers equals 2 divisions. Use the X POS control to align the marker pulses with the graticule. Now check (across the central 8 divisions) if the timebase accuracy is ±2.8%: make use of the deflection error facility of the time marker generator to check this. PERFORMANCE TEST 4.3.26 4 - 31 Time cursor accuracy (continuation of 4.3.25) This test verifies the accuracy of the time cursors. Settings/procedure: 1 - 2 3 4 5 6 - Switch the MAIN TB VARiable mode off by pressing both MAIN TB TIME/ DIV keys at a time. The message ’1-2-5 STEPS’. Select 5.00 µs/division for the MAIN TB. Switch off the deflection error facility of the time marker generator. Press the CURSORS menu key. Select ’on’ and time cursors (//) from the CURSORS menu. Select ∆ T in the READOUT menu. Requirements: - Position one cursor line exactly on the 2nd time marker on the screen and the other cursor on the 10th time marker. The distance between both cursors is now 8 time marker intervals. Check for a cursor readout between 39.5 and 40.5 µs. Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) and repeat the check in this section for the digital mode. Press the TEXT OFF key to have the full screen width available to display the time markers. Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. 4.3.27 Horizontal deflection; DELAYED TIME BASE deflection coefficients The deflection coefficients of the delayed timebase generator (DEL’D TB) are verified by means of a calibration signal. Test equipment: Fluke 5500A mode: marker (Alternative: time marker generator TG 501). 4 - 32 PERFORMANCE TEST Test set-up: Settings/procedure: 1 2 3 - 4 5 - 6 7 8 9 - 10 11 12 13 14 - Apply a 0.5 ms time marker signal to input CH1. Press the AUTOSET key. Use a 50Ω termination. For instruments with switchable 50Ω input impedance it is recommended to make use of this feature (via VERT MENU key). Press the TRIGGER menu key. Select level-pp ’off’ and ’dc’ trigger coupling from the TRIGGER MAIN TB menu. Press the TB MODE menu key and select ’trig’ from the related menu. Adjust TRIGGER LEVEL for a correctly triggered display. Set the trace height to about 4 divisions. Press the DTB menu key and select DEL’D TB ’on’ and MAIN TB ’on’ from the related menu . Set MAIN TB to 1.00 ms and DELAYED TIME BASE to 5.00 µs. Use the DELAY control (in the DELAYED TIMEBASE SECTION to set the time delay to about 0 seconds. Adjust the vertical position of the MAIN TB display with the CH1 POS control in the top half of the viewing area. Adjust the vertical position of the DELAYED TIMEBASE display with the TRACK control. Verify the DELAYED TIMEBASE deflection coefficients with MAGNIFY off (*1) and MAGNIFY on (*10) according to the requirements in the tables. Use the deflection error facility of the time marker generator. Note: - Error limits must be measured between the 2nd and the 10th graticule line (there are 11 graticule lines). These are the central 8 divisions. - With MAGNIFY on (*10), the central 10 divisions of the expanded 100 divisions of DEL’D TB are measured. PERFORMANCE TEST - 4 - 33 Only the timebase positions that are essential for instrument accuracy are checked. DEL’D TB TIME/DIV is electrically coupled to MAIN TB TIME/DIV; to check the settings in the table press only the MAIN TB TIME/DIV VAR keys. 5equirements for analog mode MAGNIFY off ( 1): * DEL’D TB setting MAIN TB setting Marker pulse Max. error 5.00 µs 20.0 µs 5.00 µs 1.00 µs 500 ns 100 ns 50.0 ns 20.0 ns (PM3390B/94B) 5.00 µs 20.0 µs 5.00 µs 1.00 µs 500 ns 100 ns 50.0 ns 20.0 ns 1.8% 1.8% 1.8% 1.8% 1.8% 1.8% 1.8% 1.8% 0.5 ms 20 µs 5 µs 1 µs 0.5 µs 0.1 µs 50 ns 20 ns Requirements for analog mode MAGNIFY on ( 10): * DEL’D TB setting MAIN TB setting Marker pulse 100 ns 10.0 ns 5.00 ns 2.00 ns (PM3390B/94B) 100 ns 10.0 ns 5.00 ns 2.00 ns 4.3.28 0.1 µs 10 ns 5 ns 2 ns Max. error 2.3% 2.3% 3.3% 3.3% Horizontal deflection; delay time multiplier In this test the minimum and maximum delay time is checked. Test equipment: None Settings/procedure and requirements: 1 2 - 3 4 5 6 - 7 - Press the AUTOSET key. Press the DTB menu key and select DEL’D TB ’on’ and MAIN TB ’on’ from the appropriate menu . Set MAIN TB to 500 ns. Set DEL’D TB to 50.0 ns. Separate the MAIN TB and DEL’D TB traces with the TRACK control. Adjust the delay time to 500.0 ns using of the DELAY control (in the DELAYED TIMEBASE section). Adjust the start of the MAIN TB display exactly on the first graticule line by using the X POS control (at maximum TRACE INTENSITY). 4 - 34 8 - 9 - 10 - 4.3.29 PERFORMANCE TEST Verify that the difference between the start of MAIN TB and the start of the intensified part is between 0.9 to 1.1 divisions. Adjust the delay time to 5.00 µs with the DELAY control (in the DELAYED TIMEBASE section). Verify that the difference between the start of MAIN TB and the start of the intensified part is between 9.9 and 10.1 divisions. Horizontal deflection; delayed timebase jitter There is a certain instability in the starting point, the so called jitter, of the DEL’D TB. The maximum allowed jitter is checked in this test. Test equipment: Fluke 5500A mode: levsine (Alternative: function generator PM5136). Test set-up: Settings/procedure: 1 2 3 - 4 - 5 6 7 - 8 - Apply a 1 MHz sine-wave signal of 120 mV(pp into 50Ω) to input CH1. Press the AUTOSET key and set for a trace-height of 6 divisions. Use a 50Ω termination. For instruments with switchable 50Ω input impedance it is recommended to make use of this feature (via VERT MENU key). Press the DTB menu key and select DEL’D TB ’on’ and MAIN TB ’on’ from the appropriate menu. Set MAIN TB to 500 µs. Set DEL’D TB to 500 ns. Adjust the delay time to 0s using the DELAY control (in the DELAYED TIMEBASE section). Switch the MAIN TB display to ’off’ in the DELAYED TIMEBASE menu; only the DEL’D TB is displayed now. PERFORMANCE TEST 4 - 35 Requirements: - Verify that the jitter of the DEL’D TB is not more than 0.4 divisions (1 part per 25000). 4.3.30 Horizontal deflection; X deflection coefficient via CH1 The amplification of the horizontal amplifier via the vertical input amplifier is checked. Test equipment: Fluke 5500A mode: volt (Alternative: Square-wave calibration generator PG 506). Test set-up: Settings/procedure: 1 - 2 3 4 5 6 7 - Apply a 1 kHz square-wave signal of 0.1V to input CH1. Output not terminated into 50Ω (’LZ’ must not appear in lower part of viewing area). Press the AUTOSET key. Set CH1 to 20 mV and DC coupled input. Press the DISPLAY menu key. Press X-DEFL softkey. Select ’on’ and ’ch1’ from the X-DEFL menu. Press the CH2 ON key and then the CH1 ON key; the result is that CH2 is on and CH1 is off. Requirements: - Verify that two dots with a horizontal distance of 4.7 ... 5.3 divisions are displayed. 4 - 36 4.3.31 PERFORMANCE TEST Horizontal deflection; X deflection coefficient via ’line’ The amplification of the horizontal amplifier via the line trigger signal is checked. Do this test only when 220V line voltage is available. Test equipment: None Settings/procedure: 1 2 3 4 - Press the AUTOSET key. Press the DISPLAY menu key. Press X-DEFL softkey. Select ’on’ and ’line’ from the X-DEFL menu. Requirements: - Verify that a horizontal line of 4.3 to 7.7 divisions is displayed when the line voltage is 220V (rms). 4.3.32 Horizontal deflection; high frequency response In this test, the bandwidth of the horizontal amplifier is checked. Test equipment: Fluke 5500A mode: levsine (Alternative: constant amplitude sine wave generator SG 503). Test set-up: PERFORMANCE TEST 4 - 37 Settings/procedure: 1 2 3 - 4 5 6 - 7 8 - Apply a 50 kHz sine-wave signal of 30 mV(pp into 50Ω) to input CH1. Press the AUTOSET key and set CH1 to 5 mV. Use a 50Ω termination. For instruments with switchable 50Ω input impedance it is recommended to make use of this feature (’LZ’ must be visible in lower part of viewing area). Press the DISPLAY menu key and then press the X-DEFL softkey. Select ’on’ and ’ch1’ from the X-DEFL menu. Press the CH2 ON key and then the CH1 ON key: the result is that CH2 is on and CH1 off. Adjust the input voltage for exactly 6 divisions horizontal deflection. Increase the input frequency up to 2 MHz. Requirements: - Verify that the trace width is at least 4.2 divisions over the complete bandwidth range. 4.3.33 Maximum phase shift between horizontal and vertical deflection There will be a certain phase shift between the horizontal and vertical amplifier. The value of this shift is measured here. Test equipment: Fluke 5500A mode: wavegen, wave sine (Alternative: function generator, PM 5136). Test set-up: 4 - 38 PERFORMANCE TEST Settings/procedure: 1 2 3 4 5 6 - Apply a 2 kHz sine-wave signal of 1.2 V(pp into 50Ω) to CH1. Press the AUTOSET key and set CH1 to 0.2V/div. Adjust the generator to a trace height of exactly 6 divisions. Press the DISPLAY menu key and then press the X-DEFL softkey. Select ’on’ and ’ch1’ from the X-DEFL menu. Increase the input frequency to 100 kHz. Requirements: Verify that the phase shift is less than 3°, ≤0.32 div, see figure). 6div ≤0.32div - MAT3842 Figure 4.5 4.3.34 Phase shift between horizontal and vertical channel MAIN TB triggering PM3390B/3394B; trigger sensitivity via CH1, CH2, CH3 and CH4 (EXT) The trigger sensitivity depends on the amplitude and frequency of the trigger signal. In this test the main timebase trigger sensitivity via the CH1, CH2, CH3 and CH4 inputs is checked. For the PM3390B, this is checked for CH1, CH2 and EXTernal TRIGger input. Test equipment: Fluke 5500A mode: levsine (Alternative: constant amplitude sine wave generators SG 503 + SG 504). PERFORMANCE TEST 4 - 39 Test set-up: Settings/procedure and requirements: 1 - 2 3 - 4 - 5 6 - 7 8 9 10 11 - 12 13 14 15 16 - 17 18 - Apply a 100 MHz sine-wave signal of 1 V(pp into 50Ω) from the SG 503 to input CH1. Press the AUTOSET key and set CH1 to 0.5V/div. Use a 50Ω termination. For instruments with switchable 50Ω input impedance it is recommended to make use of this feature (via VERT MENU key). Set the input coupling of CH1 to DC and POSition the signal in the vertical center of screen. Select ’trig’ from in the menu under the TB MODE mode key. Press the TRIGGER menu key and select level-pp ’off’ and ’dc’ trigger coupling from the TRIGGER MAIN TB menu Adjust TRIGGER LEVEL for a correctly triggered display. Decrease the amplitude of the input signal. Verify that the signal is well-triggered at amplitudes of 0.6 divisions and more. Decrease the input frequency to 50 kHz. Verify that the signal stays well-triggered at amplitudes of 0.6 divisions and more. Increase the input frequency to 200 MHz. Increase the input voltage to 1.2 division. Turn TRIGGER LEVEL. Verify that the signal is well-triggered at amplitudes of 1 division and more. Apply a 300 MHz sine-wave signal of 2V (pp into 50Ω) from the SG 504 to input CH1. Adjust the input voltage to 2 divisions. Signal must be in vertical center of screen. Verify that the signal is well-triggered at amplitudes of 2 divisions and more; adjust TRIGGER LEVEL when necessary. 4 - 40 PERFORMANCE TEST PM3394B: repeat the procedure for CH2, CH3 and CH4 for the frequencies 50 kHz (0.6 division input signal) and 300 MHz (2 division input signal) PM3390B: repeat the procedure for CH2 and the EXTTRIG input for the frequencies 50 kHz (0.6 division input signal) and 300 MHz (2 division input signal) Press the ANALOG key (’DIGITAL MODE’ is displayed briefly), then repeat the tests in this chapter for the digital mode. Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. 4.3.35 MAIN TB triggering PM3370B/3380B/3384B; trigger sensitivity via CH1, CH2, CH3 and CH4 (EXT). The trigger sensitivity depends on the amplitude and frequency of the trigger signal. In this test the main timebase trigger sensitivity via the CH1, CH2, CH3 and CH4 inputs is checked. For PM3370B and PM3380B, this is checked for CH1, CH2 and the EXTernal TRIGger input. For PM3370B; frequency setting between (). Test equipment. Fluke 5500A mode: levsine (Alternative: constant amplitude sine wave generator (SG 503) Test set-up: Settings/procedure and requirements: 1 - 2 3 4 - 5 - Apply a 50 MHz (30 MHz) sine-wave signal of 1 V(pp into 50Ω) to input CH1. Press the AUTOSET key and set CH1 to 0.5V/div. Use a 50Ω termination. Set the input coupling of CH1 to DC and POSition the signal in the vertical center of screen. Select ’trig’ from the menu under the TB MODE menu key. PERFORMANCE TEST 6 - 7 8 9 - 10 11 12 13 14 15 - 16 17 18 - 4 - 41 Press the TRIGGER menu key and select level-pp ’off’ and ’dc’ trigger coupling from the TRIGGER MAIN TB menu Adjust TRIGGER LEVEL for a correctly triggered display. Decrease the amplitude of the input signal. Verify that the signal is well-triggered at amplitudes of 0.6 divisions and more. Decrease the input frequency to 50 kHz. Verify that the signal stays well-triggered at amplitudes of 0.6 divisions and more. Increase the input frequency to 100 MHz (60 MHz). Increase the input voltage to 1.2 division. Turn TRIGGER LEVEL. Verify that the signal is well-triggered at amplitudes of 1.2 division and more. Increase the input frequency to 200 MHz (150 MHz). Adjust the input voltage to 2 divisions. Signal must be in vertical center of screen. Verify that the signal is well-triggered at amplitudes of 2 divisions and more; adjust TRIGGER LEVEL when necessary. PM3384B: repeat the procedure for CH2, CH3 and CH4 for the frequencies 50 kHz (0.6 division input signal) and 200 MHz (2 division input signal). PM3370B/80B: repeat the procedure for CH2 and the EXT TRIG input for the frequencies 50 kHz (0.6 division input signal) and 200 MHz (150 MHz) (2 division input signal). Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) and repeat the tests in this chapter for the digital mode. Press the ANALOG key (’ANALOG MODE is displayed briefly) to return to analog mode. 4.3.36 MAIN TB/DEL’D TB triggering; trigger sensitivity TVL-TVF This test checks the trigger sensitivity for television line- and field synchronization pulses. Test equipment: TV pattern generator with video output (PM 5418) 4 - 42 PERFORMANCE TEST Test set-up: Note: 1 - 2 3 4 5 6 7 - the number a various tests to be performed is numerous. Therefore it is recommended only to check the tv system(s) as used in your country. The number of tests is also limited by the available TV pattern generator. Apply a video signal to input CH1 with an amplitude of about 1V synchronization pulse amplitude; use a 75Ω termination instead of internal or external 50Ω. Press the AUTOSET key. Press menu key TRIGGER and select ’tv’ in the related menu. Select field 1 or field 2 in the menu. Select a line number (e.g. 25) by means of the TRACK control. Select pos or neg (depending on the available TV pattern generator). Select in the VIDEO SYSTEM submenu hdtv, ntsc, pal or secam (depending on the available TV pattern generator). The maximum number of lines for hdtv can be selected if hdtv is active. Requirements: - Decrease the amplitude of the input signal and verify that the signal is well-triggered on the tv pulses, at sync pulse amplitudes of 0.7 divisions and more. 4.3.37 DEL’D TB triggering PM3390B/94B; trigger sensitivity via CH1, CH2, CH3 and CH4 (EXT) The trigger sensitivity depends on the amplitude and frequency of the trigger signal. In this test the main timebase trigger sensitivity via the CH1, CH2, CH3 and CH4 inputs is checked. For the PM3390B, this is checked for CH1, CH2 and the EXTernal TRIGger input. PERFORMANCE TEST 4 - 43 Test equipment: Fluke 5500A mode: levsine (Alternative: constant amplitude sine wave generators SG 503 + SG 504). Test set-up: Settings/procedure and requirements: 1 - 2 3 - 4 - 5 6 - 7 8 - 9 - 10 11 - 12 13 - Apply a 100 MHz sine-wave signal of 1 V(pp into 50Ω) from the SG 503 to input CH1. Press the AUTOSET key and set CH1 to 0.5V/div. Use a 50Ω termination. For instruments with switchable 50Ω input impedance it is recommended to make use of this feature (via VERT MENU KEY). Set the input coupling of CH1 to DC and POSition the signal in the vertical center of screen. Select ’trig’ from the menu under the TB MODE menu key. Press the TRIGGER menu key and select level-pp ’off’ and ’dc’ trigger coupling from the TRIGGER MAIN TB menu. Adjust TRIGGER LEVEL for a correctly triggered display. Press the DTB menu key and select DEL’D TB ’on’ and MAIN TB ’on’ in the related menu. Set MAIN TB to 200 ns/division and DELAYED TIMEBASE to 20.0 ns/division. Adjust the DELAY control in the DELAYED TIMEBASE section to a delay time of 1.000 µs. Select ’trig’d’ and ’dc’ coupling from the DELAYED TIME BASE menu, and press the front panel key TRIG1. Or TRIG2 (if CH2 on), TRIG3 (if CH3 on), TRIG4 (if CH4 on). Adjust the DEL’D TB trigger level via the ∆ control for a well- triggered signal (intensified part must be visible). Operate the TRACK control to separate MAIN TB and DEL’D TB for clearly visible displays. 4 - 44 14 15 16 17 18 19 20 21 - 22 23 24 - PERFORMANCE TEST Decrease the amplitude of the input signal. Verify that the DEL’D TB is well triggered at signal amplitudes of 0.6 divisions and more. Decrease the input frequency to 50 kHz. Set the MAIN TB to 50.0 µs/division and DEL’D TB to 20.0 µs/division. Verify that the DEL’D TB stays well triggered at signal amplitudes of 0.6 divisions and more. Increase the input frequency to 200 MHz. Increase the input voltage to 1.2 division. Operate the ∆ control (controls DEL’D TB trigger level). Verify that the DEL’D TB is well triggered at all amplitudes of 1.2 divisions or more. Apply a 300 MHz sine-wave signal of 2V (pp into 50 ohm) from the SG504 generator to input CH1. Adjust the input voltage to 2 divisions. Signal must be in vertical center of screen. Verify that the DEL’D TB is well triggered at signal amplitudes of 2 divisions and more: adjust the ∆ control (DEL’D TB trigger level) if necessary. PM3394B: repeat the procedure for CH2, CH3 and CH4 for the frequencies 50 kHz (0.6 division input signal) and 300 MHz (2 division input signal). PM3390B: repeat the procedure for CH2 and the EXTTRIG input for the frequencies 50 kHz (0.6 division input signal) and 300 MHz (2 division input signal). Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) and repeat the tests in this chapter for the digital mode. Then press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. 4.3.38 DEL’D TB triggering PM3370B/80B/84B; trigger sensitivity via CH1, CH2, CH3 and CH4 (EXT). The trigger sensitivity depends on the amplitude and frequency of the trigger signal. In this test the main timebase trigger sensitivity via the CH1, CH2, CH3 and CH4 inputs is checked. For PM3370B/80B, this is checked for CH1, CH2 and the EXTernal TRIGger input. For PM3370B; frequency setting between (). Test equipment: Fluke 5500A mode: levsine (Alternative: constant amplitude sine wave generator SG 503) PERFORMANCE TEST 4 - 45 Test set-up: Settings/procedure and requirements: 1 - 2 3 4 - 5 6 - 7 8 - 9 - 10 11 - 12 13 14 15 16 - Apply a 50 MHz (30 MHz) sine-wave signal of 1 V(pp into 50Ω) from the SG 503 to input CH1. Press the AUTOSET key and set CH1 to 0.5V/div. Use a 50Ω termination. Set the input coupling of CH1 to DC and POSition the signal in the vertical center of screen. Select ’trig’ from the menu under the TB MODE menu key. Press the TRIGGER menu key and select level-pp ’off’ and ’dc’ trigger coupling from the TRIGGER MAIN TB menu Adjust TRIGGER LEVEL for a correctly triggered display. Press the DTB menu key and select DEL’D TB ’on’ and MAIN TB ’on’ from the related menu. Set the MAIN TB to 200 ns/division and DELAYED TIMEBASE to 50.0 ns/division. Adjust the DELAY control in the DELAYED TIMEBASE section to a delay time of 1.000 µs. Select ’trig’d’ and ’dc’ coupling from the DELAYED TIMEBASE menu and press the front panel key TRIG1. Or TRIG2 (if CH2 on), TRIG3 (if CH3 on), TRIG4 (if CH4 on). Adjust the DEL’D TB trigger level via the ∆ control for a well- triggered signal (intensified part must be visible). Operate the TRACK control to separate the MAIN TB and DEL’D TB for clearly visible displays. Decrease the amplitude of the input signal. Verify that the DEL’D TB is well triggered at signal amplitudes of 0.6 divisions and more. Decrease the input frequency to 50 kHz. Set the MAIN TB to 50.0 µs/division and DEL’D TB to 20.0 µs/division. 4 - 46 17 18 19 20 21 - 22 23 24 - PERFORMANCE TEST Verify that the DEL’D TB stays well triggered at signal amplitudes of 0.6 divisions and more. Increase the input frequency to 100 MHz (60 MHz). Increase the input voltage to 1.2 division. Operate the ∆ control (controls the DEL’D TB trigger level). Verify that the DEL’D TB is well triggered at all amplitudes of 1.2 division or more. Increase the input frequency to 200 MHz (150 MHz). Adjust the input voltage to 2 divisions. Verify that the DEL’D TB is well-triggered at signal amplitudes of 2 divisions and more. Signal must be in vertical center of screen. Adjust the ∆ control (DEL’D TB trigger level) if necessary. 3M3384B: repeat the procedure for CH2, CH3 and CH4 for the frequencies 50 kHz (0.6 division input signal) and 200 MHz (2 division input signal). PM3370B/80B: repeat the procedure for CH2 and the EXT TRIG input for the frequencies 50 kHz (0.6 division input signal) and 200 MHz (150 MHz) (2 division input signal). Press the ANALOG key (’DIGITAL MODE’ is displayed briefly), and repeat the tests in this chapter for the digital mode. Then press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. 4.3.39 Trigger sensitivity in logic mode PM3394B The trigger sensitivity in the logic mode ’pattern’ depends on the amplitude and frequency of the trigger signal. In this test, the trigger sensitivity is tested with a sine wave via the CH1, CH2, CH3, and CH4 inputs. Test equipment: Fluke 5500A mode: levsine (Alternative: constant amplitude sine wave generator SG 503). PERFORMANCE TEST 4 - 47 Test setup: 1 - 2 - 3 4 - 5 - 6 7 - 8 - 9 10 11 12 13 14 15 - Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) to activate the digital mode. Apply a 100 MHz sine-wave signal of 1 V(pp into 50 ohm) from the constant amplitude sine-wave generator to input CH1. Press the AUTOSET key, and set CH1 to 0.5V/division. Use a 50 ohm termination. For instruments with switchable 50 ohm input impedance it is recommended to make use of this feature (via VERT MENU key). Set the input coupling to DC and POSition the signal in the vertical center of the screen. Select 5.00 ns/division for MAIN TB. Press the TRIGGER menu key and select ’logic’, ’pattern’, and ’enter’ from the related menu. Operate the front panel keys TRIG1, TRIG2, TRIG3 and TRIG4 to obtain the trigger pattern Hxxx (x = don’t care) in the menu. Press the TB MODE menu key and select ’trig’ from the related menu. Decrease the amplitude of the generator voltage to 1 division. Turn the TRIGGER LEVEL control and check that a well-triggered signal is obtained. Apply a 300 MHz sine-wave signal of 2 V(pp into 50Ω) from the SG 504 to input CH1. Adjust the input voltage to 2 divisions. Verify that the signal is well triggered at amplitudes of 2 divisions and more; adjust TRIGGER LEVEL when necessary. Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. Repeat the procedure for CH2 with trigger pattern xHxx Repeat the procedure for CH3 with trigger pattern xxHx Repeat the procedure for CH4 with trigger pattern xxxH 4 - 48 4.3.40 PERFORMANCE TEST Trigger sensitivity in logic mode PM3384B The trigger sensitivity in the logic mode ’pattern’ depends on the amplitude and frequency of the trigger signal. In this test, the trigger sensitivity is tested with a sine wave via the CH1, CH2, CH3, and CH4 inputs. Test equipment: Fluke 5500A mode: levsine: (Alternative: constant amplitude sine wave generator SG 503). Test setup: 1 - 2 - 3 4 5 - 6 7 - 8 - 9 10 11 12 13 - Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) to activate the digital mode. Apply a 50 MHz sine-wave signal of 1 V(pp into 50 ohm) from the constant amplitude sine-wave generator to input CH1. Press the AUTOSET key, and set CH1 to 0.5V/division. Use a 50 ohm termination. Set the input coupling to DC and POSition the signal in the vertical center of the screen. Select 5.00 ns/division for MAIN TB. Press the TRIGGER menu key and select ’logic’, ’pattern’, and ’enter’ from the related menu. Operate the front panel keys TRIG1, TRIG2, TRIG3 and TRIG4 to obtain the trigger pattern Hxxx (x = don’t care) in the menu. Press the TB MODE menu key and select ’trig’ from the related menu. Decrease the amplitude of the generator voltage to 1 division. Turn the TRIGGER LEVEL control and check that a well-triggered signal is obtained. Increase the input frequency to 200 MHz. Increase the input voltage to 2 division. PERFORMANCE TEST 14 15 - 4 - 49 Turn the TRIGGER LEVEL control, and check that a well-triggered signal is obtained. Press the ANALOG key (’ANALOG MODE’ is displayed briefly) to return to analog mode. Repeat the procedure for CH2 with trigger pattern xHxx Repeat the procedure for CH3 with trigger pattern xxHx Repeat the procedure for CH4 with trigger pattern xxxH 4.3.41 Z-MOD sensitivity This test checks the sensitivity of the Z modulation facility. Test equipment: Fluke 5500A mode: wavegen, wave square (Alternative: function generator PM 5136). T-piece. Test set-up: Settings/procedure and requirements: 1 - 2 3 4 5 6 - Apply a 1 kHz square-wave signal, duty cycle 50%, amplitude between 0 to +2.5V, to input CH1. Adjust the generator to a signal of 2.5 Vpp with an offset of 1.25V. Press the AUTOSET key. Set MTB to 0.5 ms/div. Set the trace of CH1 in mid position with the CH1 POS control. Apply the same signal by means of the T-piece to the Z input (rear side). Adjust TRACE INTENSITY so that only the bottom half of the squarewave is displayed. The top half must be invisible (0.5 ms light on; 0.5 ms light off). 4 - 50 7 8 9 - 4.3.42 PERFORMANCE TEST Decrease the input signal to 0.5 Vpp with an offset of 0.25V. Set CH1 to 0.5V/division. Verify that the top half of the square wave is visible at full intensity. Probe Adjust signal; frequency and output voltage The Probe Adjust signal is a calibration signal with fixed frequency and voltage. In this test, the values of frequency and voltage are checked. Test equipment: None Test set-up: OSCILLOSCOPE UNDER TEST Probe Adjust CH1 CH2 PROBE + CABLE CH3 CH4 MAT4137 9303 Settings/procedure: 1 - 2 3 4 - Connect the Probe Adjust signal to input CH1 and press the AUTOSET key. Select GND of CH1. Set the trace in the center of the screen. Select DC input coupling for CH1. Requirements: 1 - 2 - Verify that a positive going square-wave signal of 0.6 V(pp) is displayed, i.e. 3 divisions vertical at 0.2V. Verify that the frequency of the displayed signal is about 2 kHz, i.e. a period time between 4.0 … 6.0 divisions horizontal at MTB 100 µs/div. PERFORMANCE TEST 4.3.43 4 - 51 Auto range functions The AUTO RANGE function of the vertical channels automatically selects the input sensitivity. The result is that the input signal is displayed with 2 to 6.4 divisions amplitude. The AUTO RANGE function of the main time base (MAIN TB) adjusts the time base automatically so that approximately 2 to 6 waveform periods are displayed. Test equipment: Fluke 5500A mode: wavegen, wave sine (Alternative: function generator, PM 5136) Settings/procedure: 1 2 3 - 4 - 5 - 6 - Apply a 50kHz sine-wave signal of 2 V(pp) to CH1. Press the AUTOSET key. Adjust the generator output voltage to maximum (20 ... 30 V approximately). The signal amplitude now exceeds the 8 div screen height. Press the ANALOG key (’DIGITAL MODE’ is displayed briefly) to switch the digital mode to on. Press the CH1 AUTO RANGE key. Check that the vertical amplitude is automatically adjusted to between 2 and 6.4 divisions. Vary the generator output voltage from maximum to 100 mV. Requirements: - Check that the signal amplitude stays between 2 and 6.4 divisions. Repeat this procedure for the other vertical channels that have an AUTO RANGE key. 4 - 52 PERFORMANCE TEST Settings/procedure: 1 2 3 4 - Adjust the generator to a 1 kHz sine-wave of 2 V(pp) applied to CH1. Press the AUTOSET key. Press the AUTO RANGE key of the main time base MAIN TB. Vary the generator output frequency between 1kHz and maximum (10 MHz approxinately). Requirement: - Check that between 2 and 6 waveform periods are displayed. 4.3.44 Testing the optional auxiliary outputs MTB-GATE and DTB-GATE outputs Test equipment: measuring oscilloscope. Test set up: Settings/procedure: Oscilloscope under test: - Take care that no input signal is applied to the oscilloscope inputs. - Press the STATUS and TEXT OFF keys simultaneously. This assures that the oscilloscope occupies its default position. - Press the DTB menu key to display the DELAYED TIME BASE menu. Select the ‘on’ position of the DEL’D TB softkey. The result is that MTB is in 1.00 ms/ div and that DTB is in 100 µs/div and that both time bases are on. - Apply a 50Ω coaxial cable to rear panel output ‘MTB-GATE’. - Apply another 50Ω coaxial cable to rear panel output ‘DTB-GATE’. PERFORMANCE TEST 4 - 53 Measuring oscilloscope: - Apply the coaxial cable from signal ‘MTB GATE’ of the oscilloscope under test to input CH1 of the measuring oscilloscope. - Apply the coaxial cable from signal ‘DTB GATE’ of the oscilloscope under test to input CH2 of the measuring oscilloscope. - Press the green AUTOSET key. - Adjust CH1 and CH2 to DC input coupling; if the ocilloscope is in 50Ω (‘LZ’) position, select an input impedance of 1MΩ. - Adjust CH1 and CH2 to 2 V/div. - Select 2 ms/div for MTB. Requirements: - Verify that two square-wave signals are displayed via CH1 and CH2 of the measuring oscilloscope. Verify that the ‘low’ level of both square-waves is between 0 .. 0.4 V. Verify that the ‘high’ level of both square-waves is between 2.4 .. 5 V. Verify that the ‘MTB GATE’ signal (is displayed via CH1) is high during 10 ms or more. Verify that the ‘DTB GATE’ signal (is displayed via CH2) is high during 1 ms or more. Y-OUTput signal Test equipment: Fluke 5500A mode: levsine (Alternative: constant amplitude sine-wave generator SG503). Test set up: Settings/procedure: - - Apply a 50 kHz sine-wave signal of 600 mV (pp into 50Ω) to input CH1 and press the green AUTOSET key. Use external 50Ω termination at the CH1 input. Use the internal termination of the oscilloscope, when available (if active, the text ‘LZ’ is visible in the lower part of the viewing area). Set CH1 to 0.1 V/div. 4 - 54 - - PERFORMANCE TEST Adjust the generator signal to an amplitude of exactly 6 divisions. Connect the rear side output Y-OUT via a coaxial cable with the CH2 input. Use external 50Ω termination at the CH2 input. Use the internal termination of the oscilloscope, when available (if active, the text ‘LZ’ is visible in the lower part of the viewing area). Switch CH2 to on and CH1 to off. Put CH2 in 10 mV/div. Requirement: Check for a vertical amplitude of the 50 kHz sine-wave signal between 5.3 .. 6.7 divisions. Settings/procedure: - Adjust the 50 kHz sine-wave signal to an amplitude of exactly 6 divisions. Slowly increase the frequency of the generator to 60 MHz (PM3370B) or 100 MHz (PM3380B/84B) or 200 MHz (PM3390B/94B). Requirement: Verify that the displayed sine-wave does not drop below an amplitude of 3 divisions across the frequency range 50 kHz .. full bandwidth. The observed bandwidth curve is that of CH1 and CH2 in cascade. EXT TRIGger input Test equipment: - Fluke 5500A mode: levsine (Alternative: constant amplitude sine-wave generator SG503). Power splitter. Test set up: PERFORMANCE TEST 4 - 55 Settings/procedure: - - Use a power splitter and two coaxial 50Ω cables to apply the generator output signal to input CH1 and the rear panel input ‘EXT TRIG’. Use an external 50Ω termination at the end of each cable. When available, use the internal termination of input CH1 (if active, the text ‘LZ’ is visible in the lower part of the viewing area). Adjust the generator output signal for a 50 kHz sine-wave of 200 mV (pp output amplitude into 50Ω). Press the green AUTOSET key. Press the TRIGGER menu key to display the TRIGGER MAIN TB menu. Select with softkey ‘ch1, extern, line’ the ‘extern’ trigger source. Put CH1 in 50 mV/div and adjust the generator output voltage to a vertical display of 2 divisions. Slowly increase the frequency of the generator signal from 50 kHz to 5 MHz. Requirement: Check that the signal diplayed via CH1 stays well triggered across the indicated frequency range (the ‘ARM’D LED must stay dimmed). Settings/procedure: - Adjust the generator output voltage to a vertical display of 4 divisions. Slowly increase the frequency of the generator signal from 5 MHz to 10 MHz. Requirements: Check that the signal diplayed via CH1 stays well triggered across the indicated frequency range (the ‘ARM’D LED must stay dimmed). PREVENTIVE MAINTENANCE 5-1 5 PREVENTIVE MAINTENANCE 5.1 GENERAL INFORMATION This instrument normally requires no maintenance, since none of its components is subject to wear. However, to ensure reliable and trouble-free operation, the instrument should not be exposed to moisture, heat, corrosive elements or excessive dust. 5.2 REMOVING THE BEZEL AND THE CONTRAST FILTER The bezel can be removed by pulling the upper rim away from the front panel. This makes the contrast filter accessible for e.g. cleaning. The filter has open spaces at the edges that allow to lift it from the screen with a small screwdriver. When cleaning the filter, ensure that a soft cloth is used. The cloth must be free from dust and abrasive particles in order to prevent scratches. When installing the filter take care that the side facing the screen is the one that has a small distance from the screen. When installing the bezel take care that the grooves for text/softkey alignment are on the right hand side. 5.3 CLEANING Clean the oscilloscope with a damp cloth and a mild soap (remove all input signals and disconnect the instrument line power). Do not use abrasives, solvents or alcohol. These may damage the text on the instrument. 5.4 RECALIBRATION From experience, it is expected that the instrument operates within its specifications for a period of at least 2,000 hours, or for one year if used infrequently. Recalibration must be carried out by qualified personnel only. 5-2 PREVENTIVE MAINTENANCE 5.5 MAINTENANCE Do not open the oscilloscope: it contains no user-replaceable parts with the exception of the two memory back-up batteries. Maintenance should only be performed by authorized personnel (e.g. by an authorized Fluke Service Center; for addresses refer to last page of this manual). SERVICE CENTERS To locate an authorized service center, visit us on the World Wide Web: http://www.fluke.com or call Fluke using any of the phone numbers listed below: +1-888-993-5853 in U.S.A. and Canada +31-402-678-200 in Europe +1-425-356-5500 from other countries SERVICE-ZENTREN Wenn Sie die Adresse eines authorizierten Fluke-Servicezentrums brauchen, besuchen Sie uns bitte auf dem World Wide Web: http://www.fluke.com oder rufen Sie uns unter einer der nachstehenden Telefonnummern an: +1-888-993-5853 in den U.S.A. und Canada +31-402-678-200 in Europe +1-425-356-5500 von anderen Ländern aus CENTRES DE SERVICE APRES-VENTE Pour localiser un centre de service, visitez-nous sur le World Wide Web: http://www.fluke.com ou téléphonez à Fluke: +1-888-993-5853 aux U.S.A. et au Canada +31-402-678-200 en Europe +1-425-356-5500 pour les autres pays
advertisement