MAGNELAB
DC Voltage Transducer DVT-1000
DIN Rail Mounted Isolated Transducer
Description:
The DVT Transducer is designed to convert a DC Voltage input to either a 4-20mA or a voltage standard output that is proportional to the input. It is also perfect for solar-string voltage monitoring. The transducer provides effective and safe isolation between the input and output.
Electrical Specifications:
• Primary voltage range: 10-1000Vdc
• Output 4-20mA, 0-1Vdc, 0-5Vdc (see chart below)
• Accuracy: ±1% over range
• Linearity: 0.5% over range
• Response time: 0.09mSec
PART NUMBER AND RATING INPUT OUTPUT
DVT-1000-420
DVT-1000-V01
DVT-1000-V05
1000 Volt
1000 Volt
1000 Volt
4-20mA
0-1Vdc
0-5Vdc
Mechanical Specifications:
• DIN Rail EN 50 022 or wall mounting
• Screw type terminals
• Warranty - 7 years
• Response time: 0.09mSec
Safety:
• Conforms to UL508C
• Certified to CSA C22.2
Applications:
• Solar-string monitoring
• Power sensing
• Over/under voltage
• Battery and energy storage
• Working Range: 0–120%
• Overload: 150% continuous
• Temperature: -30˚C to 70˚C operating
• Humidity: 90% operating
• Isolation: 4.5KV, 1 minute
• Supply voltage: 15–48Vdc
DIMENSION INCH MM
H
W
L
2.320
0.710
3.520
58.93
18.03
89.41
Top View
MAGNELAB
MAG-DVT-1000-420 Voltage Transducer
GND
-
4-20mA out www.Magnelab.com
c
L
H
W
RoHS ISO 9100:2000
R e v . A M a g n e l a b . c o m