Description:

The DVT Transducer is designed to convert a DC Voltage input to either a 4-20mA or a voltage standard output that is proportional to the input. It is also perfect for solar-string voltage monitoring. The transducer provides effective and safe isolation between the input and output.

Electrical Specifications:

• Primary voltage range: 10-1000Vdc

• Output 4-20mA, 0-1Vdc, 0-5Vdc (see chart below)

• Accuracy: ±1% over range

• Linearity: 0.5% over range

• Response time: 0.09mSec

PART NUMBER AND RATING INPUT OUTPUT

DVT-1000-420

DVT-1000-V01

DVT-1000-V05

1000 Volt

1000 Volt

1000 Volt

4-20mA

0-1Vdc

0-5Vdc

Mechanical Specifications:

• DIN Rail EN 50 022 or wall mounting

• Screw type terminals

• Warranty - 7 years

• Response time: 0.09mSec

Safety:

• Conforms to UL508C

• Certified to CSA C22.2

Applications:

• Solar-string monitoring

• Power sensing

• Over/under voltage

• Battery and energy storage

• Working Range: 0–120%

• Overload: 150% continuous

• Temperature: -30˚C to 70˚C operating

• Humidity: 90% operating

• Isolation: 4.5KV, 1 minute

• Supply voltage: 15–48Vdc

DIMENSION INCH MM

H

W

L

2.320

0.710

3.520

58.93

18.03

89.41

Top View

MAGNELAB

MAG-DVT-1000-420 Voltage Transducer

GND

-

4-20mA out www.Magnelab.com

c

L

H

W

RoHS ISO 9100:2000