VAX Replacement System


Add to my manuals
6 Pages

advertisement

VAX Replacement System | Manualzz

VAX Replacement System

Model NuVAX 3200

Your VAX has been a dependable workhorse for decades, but,

What do you do if it stops running?

Can you obtain spare parts?

Do you have knowledgeable staff to troubleshoot

the old system?

You want to get rid of the high maintenance overhead, but how do you connect a new system to your expensive, hardto-replace externally connected equipment?

You might be able to replace it all –

system, software and external equipment –

for a significant capital investment;

Or, save time and money and choose NuVAX 3200:

Retain your investment in software

Preserve your investment in external equipment

Migrate to a brand new system with a new warranty.

NuVAX 3200 is a modern, industry-standard system that replaces the VAX chassis, CPU, memory, and mass storage. Your current VAX disk images can be transferred onto a NuVAX system running your existing operating system and applications.

You can select from a variety of new technology controllers such as the DRV11-WA and DRQ3B to replace popular legacy Qbus interfaces. When a new interface is not available for your application, you can choose to retain your interface in a Qbus chassis connected to the NuVAX, or we can design a replacement.

MicroVAX Replacement Systems

Eliminate

Obsolete disks and tapes

High maintenance costs

Aging, unreliable equipment

Preserve

Existing applications

Specialized Qbus I/O interfaces

Packaging and cables

Improve

Performance up to 24 VUPS

New equipment, new warranty

High performance disk

Qbus Support

Support for multiple Qbus devices

Follows all Qbus rules and specifications

Both Qbus PIO and DMA data transers are supported as well as all four Qbus interrupts

Qbus PIO and DMA data transfers occur at maximum Qbus speeds; throughput is limited only by the Qbus device(s)

VAX Compatibility

Software compatible with existing applications

Hardware compatible

Diagnostic compatible

VAX is a registered trademark of Hewlett-Packard Company.

www.logical-co.com

1 120416 Rev I

Specifications

Physical

Standard 4U rack-mount chassis

(20 inch depth)

Processors Supported

MicroVAX II, MicroVAX 3300, 3400,

3500, 3600, 3800, and 3900

Disks Emulated RQDX3, KDA50

Tapes Emulated

VAX Memory

TQK50, TQK70

64 MB

Hard Drive

Ethernet

Removable 80GB SATA drive - one system drive, one optional data drive

One port: Web Server console

RS232 Serial Port

(COM1)

USB

Speed

Keyboard, VGA

Mouse

Printer

Console (TT0) only

Fixed at 9600 bps

Not supported

Not supported

Not supported

LPV11

Power

Available Slots for I/O

VAX/VMS License

Operating Environment

Temperature

Relative Humidity

Storage Environment

300 W @ 115/230 VAC,

50/60 Hz auto-sensing

5

Qualifies for transfer

10° to 40° C (50° to 104° F)

20 to 80% non-condensing

Temperature -40° to 60° C (-40° to 140° F)

Relative Humidity 10% to 90% non-condensing

MicroVAX Replacement Systems

Ordering Information

All NuVAX 3200 systems support external Qbus capability.

A removable data drive and KWV11C clock support are optional. Qbus interconnect is offered for both BA23/123 and BA200/400 enclosures.

Description Model

Base System

System with KWV11-C clock

MVX-3200-BD

MVX-3200-DD

Data Drive DRV-0017-A

Interconnect kit for BA23/123 CAQ-2101-AA

M3107

M3119

M7516

M7651

M7651 +

M9056

M7658

M7658 +

APG-63(V)1

M7941

M8049

M8634

Interconnect kit for BA200/400.

Includes DEC M9405-PA.

CAQ-2102-AA

Interconnect kit for BA23/123.

Connects to existing DEC M9405.

CPX-2102-AA

Option modules are listed below and described on the following pages.

DEC

Module

DEC Interface

Option

Module

Page

M3104 DHV11 CCI-0008-AA 4

M3106 DZQ11 CCI-0008-AA 4

DHQ11

CXY08

DELQA

DRV11-WA

DRV11-WA +

Long Line

DRQ3B

CCI-0008-AA

CCI-0008-AA

CEI-2000-A 4

DQP-1100-AA 4

4

4

DQP-1100 AB

DQP-1500-AA

4

5

None

DRQ3B + DRPI DQP-1501-AA

DRV11

DRV11-J

IEQ11-A

Unibus Adapter

+ 2 KW11-K

DQP-1300-AA

DQP-1400-AA

DQP-3100-AA

AQP-2303-AA

5

5

6

6

6 www.logical-co.com

2 120416 Rev I

Update Your Equipment

MicroVAX Replacement Systems

Option Modules

Option modules are plug-and-play replacements for popular legacy Digital interfaces. Option modules install in a MVX-3200 system and offer the same functionality as the Digital equivalent, thus allowing users to migrate from their

Qbus systems to NuVAX 3200 systems and maintain their investment in software and user equipment.

New Technology

State-of-the-art design

New equipment, new warranty

Software Compatible

Application compatible

Diagnostic compatible

Hardware Compatible

Signal compatible

Connector and switch compatible

Module Interconnect

Option modules install into a single slot and connect to the NuVAX bus adapter, and optionally, to other option modules by way of

Module Interconnects.

Use existing user cables and externally connected equipment

Option modules for the NuVAX 3200 are described on the following pages.

www.logical-co.com

3 120416 Rev I

Model

DEC Module

Function

Power

User Connection

Line Parameters

MicroVAX Replacement Systems

CCI-0008-AA Description DHV/DHQ Interface, 8-port

M3104, M3106, M3107, M3119

8-port RS232 asynchronous communication controller with external

DB25 user connection.

1.8 amps @ +5V

Eight DB25-P connectors

Data bits: 8, fixed

Stop bits: 1, fixed

Parity: No parity, fixed

Baud Rates: 9600, fixed

Part No: CCI-0008-AA Package includes controller and DB25 octopus cable.

Model CEI-2000-A Description Dual Port Ethernet Module

DEC Module

Function

M7516

Dual-port Ethernet controller that enables higher-level software protocols, such as DECnet or TCPIP, to communicate over an Ethernet network. The CEI-2000 conforms with the IEEE Specification 802.3 for Local Area Networks. One port reserved for Web Server use when CCI-0008 is used.

1.0 amp @ +5V Power

User Connection Two RJ45 Ethernet connectors

Part No: CEI-2000-A Dual-port PCI Ethernet controller. DEC hardware and software compatible.

Model DQP-1100-AA/AB Description DRV11-WA Interface

DEC Module

Function

M7651 + M9056 for differential

16-bit parallel user interface for PIO and DMA transfers between a Qbus system and external equipment. It can also serve as a link between a Qbus system and another computer with a DRV11-

WA or DR11-W compatible interface. The board supports 22-bit addressing and data transfers at rates up to 400 Kbps in burst mode.

0.5 amps @ +5V, 0.3 amps @ +3.3V

Power

User Connection Two 40-pin connectors, two 60-pin connectors for differential

Part No: DQP-1100-AA Standard package includes controller, Module Interconnect, Cable

Adapter Panel, 8’, 100-pin Connection Cable, and test cable.

Part No: DQP-1100-AB Package includes controller, Module Interconnect, Differential

Cable Adapter Panel, 8’ 100-pin Connection Cable, test cable.

www.logical-co.com

4 120416 Rev I

Model

MicroVAX Replacement Systems

DQP-1500-AA Description DRQ3B Interface

DEC Module

Function

M7658

High performance 16-bit parallel interface designed for real-time data collection or for high-speed inter-processor communications. It provides PIO and DMA transfers between a Qbus system and external equipment at transfer rates of up to 1.3 MHz of 16-bit words.

1 amp @ +5V, 0.3 amps @ +3.3V

Power

User Connection Two 50-pin connectors

Part No: DQP-1500-AA Standard package includes controller, Module interconnect, Cable

Adapter Panel, 8’, 100-pin Connection Cable, and test cable.

Model

DEC Module

Function

Power

User Connection

DQP-1501-AA Description DRQ3B/DRPI Interface

M7658 plus APG-63(V)1

Like the DRQ3B, the DQP-1501 is a high performance, 16-bit parallel interface designed for real-time data collection or for high-speed inter-processor communications. It provides PIO and DMA transfers to the DRPI interface at transfer rates of up to 1.3 MHz of 16-bit words. Plug-and-play replacement for the APG-63(V)1 Radar Data Processor (DRPI) controller.

1 amp @ +5V, 0.3 amps @ +3.3

One 50-pin male ribbon connector

Model DQP-1300-AA Description DRV11 Interface

DEC Module

Function

M7941

16-bit parallel user interface for transfers between a Qbus system and parallel line TTL-based user equipment. It can also serve as a link between a Qbus system and another computer with a DRV11 or DR11-C compatible interface. This device is not supported by VMS autoconfigure.

0.5 amps @ +5V, 0.3 amps @ +3.3V

Power

User Connection Two 40-pin connectors

Part No: DQP-1300-AA Standard package includes controller, Module Interconnect,

Cable Adapter Panel, 8’, 100-pin Connection Cable, and test cable.

www.logical-co.com

5 120416 Rev I

Model

MicroVAX Replacement Systems

DQP-1400-AA Description DRV11-J Interface

DEC Module

Function

M8049

Parallel interface that provides 64 input/output data lines.

Interrupt ability up to 16 lines with programmable interrupt vectors and program selection of fixed or rotating interrupt priority.

0.5 amps @ +5V, 0.3 amps @ +3.3V

Power

User Connection Two 50-pin connectors

Part No: DQP-1400-AA Includes controller, Module Interconnect, Cable Adapter Panel,

8’, 100-pin Connection Cable, and test cable.

Model

DEC Module

Function

DQP-3100-AA Description IEQ11 Interface

M8634

DMA controller that interfaces a Qbus system to two independent channels that are compatible with both the IEC and IEEE instrument buses. The instrument buses conform to both the European

Standard IEC 625-1 and the U. S. Standard IEEE 488.1-1987. Each instrument bus can have up to fifteen devices, including the DQP-3100, in a sequential configuration.

0.5 amps @ +5V, 0.3 amps @ +3.3V

Power

User Connection IEEE IEEE-488 standard 24-pin connector

IEC IEC-625 standard 25-pin connector

One connector per channel.

Part No: DQP-3100-AA Includes controller, Module Interconnect, IEC625 to IEEE488 cables, and test cable.

Model AQP-2303-AA Description Unibus Adapter + 2 KW11-K Clocks

Function

Power

External Unibus adapter with two KW11-K clocks. Allows Unibus controllers in an external chassis to be accessed from the NuVAX system while also providing two KW11-K clocks with fixed address and vector. Clocks can be disabled.

2.5 amps @ +5V, 0.5 amps @ +3.3V

Part No: AQP-2302-AA Includes controller, Module Interconnect, Unibus module, Cable

Adapter Panel and 8’, 100-pin Connection Cable www.logical-co.com

6 120416 Rev I

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals