E5
D811007 15-09-99 Vers. 03
ELECTROMECHANICAL
AUTOMATION
FOR SWING
GATES
E5
1) GENERAL OUTLINE
The E5 model consists of a compact electromechanical gearmotor with minimum
overall dimensions which can be installed on any post or pillar thanks to its versatility. Gate locking in the closing position is guaranteed by an electric lock. The
reversibility of the gearmotor allows immediate manual manoeuvring of the gate in
case of emergency, by means of the appropriate personalised key releasing the
electric lock. Total anti-squash safety is provided by a multiple-disk clutch and the
end-of-stroke operation is set by a timer.
The gearmotor (fig.1) is made up of : Motor single-block “M”, Epicycloidal reducing gear “R”, Multiple-disk mechanical clutch “F”, Pushing arm “B”.
2) TECHNICAL SPECIFICATIONS
Power supply
230 V~ ±10% 50/60 Hz single-phase (*)
Motor
1400 rpm
Max. power
250 W
Reduction ratio
1/1296
Capacitor
8 µF
Absorbed current
0,8 A
Lubrication
Permanent grease
Max. pushing force
350 Nm
Opening speed
22 sec (~6 degrees/sec)
Max. leaf weight
200 kg
Max. leaf length
1.800 mm
Max opening degrees
130° 180° with slide arm
Impact reaction
Multiple-disk mechanical clutch
Manual manoeuvre
Electric lock release with key
No. manoeuvres in 24 h
50
Environmental conditions
-10°C to +60°C
Degree of protection
IP 44
Controller weight
8 kg
Dimensions
See fig.2
(*) Special voltages on request
122
3) INSTALLATION OF THE ACTUATOR
3.1) Preliminary checks
Check:
that the structure of the gate is strong enough. The fixing position must be determined according to the leaf structure. In any case, the drive arm must push against
a reinforced point in the leaf; that the leaves can be moved manually without
excessive effort for the whole of their stroke; If the gate being installed is not new,
check whether its components are worn.
Repair or replace any worn or damaged parts.
Automation reliability and safety are directly influenced by the condition of the gate
structure.
3.2) Standard installation
Fig. 3 shows the standard installation position for Mod. E5. However, if the
automation must be fitted onto a gate with a pedestrian access and with a leaf
with up to 1.4 m length, the opening speed can be increased by bringing the gate
fastening position ìAî near to the hinge-pivot (fig.4) or by shortening the articulated lever ìL2î (fig.5).
If the minimum value equal to 210mm indicated in the drawing of fig.6 is not available due to the presence of a wall in the corner, use a slide arm (fig.7);
in this case, make sure that the length of the leaf does not exceed 1.6 metres and
its weight is 100 kg max.
If the maximum value equal to 200mm (fig.3) is not available due to a too large
gate-post, use version E5L with both arms “L1-L2” extended (fig.8).
For heavy gates with leaves with up to 2 m length 200 kg weight, request an
extended “L2” arm (fig.9) featuring increased power; in this case, the opening time
will be longer because the rotation degrees of lever “L1” are increased. If the
automation must be fitted onto a gate with 180° angular opening (fig.10) or there
is no space in the gate-post to mount the motor, a recess should be made in the
leaf in correspondence with the gate hinge- pivot (fig.11); in this case the weight
of the leaf must not be supported by the gearmotor and the length of the single
leaf must not exceed 1.6 m and its weight not be greater than 100 kg.
- With a good electric welding (fig. 12) if the gate-post in made of metal.
- If the gate-post is in brick, the plate must be set soundly into the post using adequately sized cramps “Z” welded to the back of the plate (fig. 13).
- If the gate-post is in stone and the gate is small and therefore does not require
excessive power to be opened, the plate can be mounted with four metal expansion plugs “T” (fig. 14).
- If the gate-post is in stone and a large gate is being installed it would be better
to weld the plate to a corner plate ìCî fixed with four expansion plugs (fig. 15).
- After fastening the anchoring plate, fit the gearmotor (fig. 16).
- Close the gate and loosen the clutch (fig. 23). Position the drive arm so as to create a pressing angle as shown in the figures for positioning.
- Temporarily lock the fastening element “A” (fig. 17) to the leaf (using locking pliers) and open the leaf manually.
Check that the drive arm does not cause any crushing or entanglement risks when
moving.
- Secure the fastening fork “A” to the leaf (fig. 17) using the four threaded holes ìFî
to be made in the selected position.
Check that the arm is level (fig. 18).
- In the case of gearmotors equipped with the slide arm Mod. E5S, the slide “S”
should be secured with its sliding slit facing the ground (fig, 19); the slide must
be located at the maximum distance from the gate-post allowed by the arm “L1”.
5) FITTING THE ELECTRIC LOCK
Due to the reversibility of the gearmotor, an electric lock must be fitted.
The company supplies a special electric lock Mod. EBP (fig. 20) which consists of
a continuous electromagnet with ground catch. This device remains energised
during the total operation time of the gearmotor so as the bolt “D” can reach the
closing limit stop lifted without creating any friction with the ground and guaranteeing a smooth movement.
If the gates has two leaves, the leaf equipped with the electric lock should close last.
Use a control unit with closing delay adjustment for the second leaf.
6) GATE STOP LIMITS
It is compulsory to fit the gate stop limits ìFî (fig.21), both in opening and closing
positions, to stop the strokes of the leaves in the desired positions.
7) ELECTRICAL PLANT SET-UP
Set the electrical plant as shown in fig. 22 according to the current standards for
electrical plants CEI 64-8, IEC364, Harmonization HD384 and other national regulations. Keep the power supply connections definitely separated from the auxiliary
connections (photocells, control devices, etc.).
Fig. 22 indicates the number of connections and the sections for 100 m. long
power supply cables. For distances of over 100 m., calculate the cable section
depending on the automation actual load.
The automation main components are the following (fig. 22):
I Type approved omnipolar switch with 3 mm min. contact opening provided with
overload and short-circuit protection, used to break the automation connection
from the mains. If not present, provide the automation with a type approved differential switch with adequate capacity and a 0.03 A threshold.
QR
Control unit with built-in receiver
SPL
Pre-heating board on the control panel for operation at temperatures
below -10° C (optional)
S
Key selector
AL
Blinker tuned in with antenna
M
Actuators
E
Electric lock
Fte, Fre Pair of outside photocells
Fti, Fri Pair of inside photocells with columns
T
1-2-4 channel transmitter
8) MOTOR TORQUE ADJUSTMENT (CLUTCH)
The motor torque adjustment is carried out in the gearmotor by means of the
mechanical multiple-disk clutch (fig.23).
The adjustment of the clutch must be carried out by qualified personnel (installer)
and includes the calibration of the clutch to the minimum force needed to complete full opening and closing strokes. The calibration must never exceed the values of the pushing force measured on the leaf edge according to the national standards in force. In Italy the admitted value is equal to 150N.
WARNING: Do not secure completely the adjustment screw of this device;
this could compromise the safety of the automation and the controller could
get damaged.
Carry out the adjustment as follows:
Remove the cover “A” and rotate from time to time small sections of the screw “C”
using the appropriate spanner “B”. To tighten the clutch, rotate the screw clockwise (towards +), to loosen the clutch, rotate the screw anticlockwise (towards -).
Carry out the adjustment on every controller mounted and refit the cover “A”.
Fig.24 indicates the assembly sequence for the clutch components: A)
cover, C) adjustment screw, E) Belleville washer, F) clutch disks with
inside keying, G) clutch disks with outside keying, H) arm, I) shim washer,
L) grooved reduction shaft.
9) LIMIT SWITCHES
The controllers are not equipped with electric limit switches. For this reason, they
must be controlled by a control unit with adjustment of the operation time. When
the leaf reaches the gate stop limit the clutch slides and the motor remains energised until the total operation time set has elapsed. The operation time can be set
on the control unit by means of a trimmer. The time is correct when the time set is
3-5 seconds greater than the actual time needed to complete one full opening and
AUTOMATION FOR SWING GATES
D811007_03
This product complies with recognised technical standards and safety regulations.
We declare that this product is in conformity with the following European
Directives: 89/336/EEC, 73/23/EEC (amended by RL 91/263/EEC, 92/31/EEC and
93/68/EEC).
E5
closing cycle. If the leaf is too slow, adjust the operation time in closing position.
The less the movement time at the end of stroke is, the longer the clutch life will be.
If external electric limit switches are used, refer to the two different installation
methods in fig.25-26. The limit switches must be sealed. To connect the limit
switches, refer to the instructions for the control unit.
10) EMERGENCY MANOEUVRE
Since the gearmotor is reversible, release the electric lock and move the
leaves manually in the case of a power failure. When the power supply
has been restored, the automation operates automatically.
11) CHECKING THE AUTOMATION
Before considering the automation completely operational, the following checks
must be made with great care:
Check that all the safety means work properly (i.e. clutch, photocells, pneumatic
skirts, etc.).
Check that the thrust (anti-squash) of the leaf is within the limits prescribed by the
standards in force (150N).
Check the manual opening control.
Check the opening and closing manoeuvres using the controls.
Check the control unitís electronic logic in normal or customised operation.
12) USE OF THE AUTOMATION
Since the automation may be remote controlled either by radio or a start button
(and therefore not visually), it is essential that all safeties are checked frequently.
Any malfunction should be corrected immediately by qualified personnel.
Keep children at a safe distance from the field of action of the automation.
3) Check if the clutch slides and, if necessary, tighten it by rotating the screw
towards the + sign (max. thrust allowed 150N).
4) If the motor runs in the direction opposite to the right one, invert the driving connections of the motor (check rotation by lifting the clutch cover).
If after having carried out the checks listed above the problem persists, replace the
controller.
15.2) The gate does not open or close. The motor does not run and no sound
is heard.
1) Check that the control unit is correctly powered.
2) Check that the photocells or the rubber skirts are not engaged.
2) Check that the electronic equipment is correctly powered. Check that the fuses
are not damaged.
4) Check that the electronic functions of the equipment are correct by means of
the diagnostic LEDs or through a visual inspection.
5) Check that no remote controls, start buttons or other devices are keeping the
start contact (N.C.) closed.
If after having carried out the checks listed above the problem persists, replace the
control unit.
15.3) The noise originating from the motor is high when the leaf encounters
the gate stop limit.
1) When the clutch slides because the leaf has reached the gate stop limit, the leaf
must be still and no oscillations should be noticed. If jog movements are
noticed, reinforce the leaf so as to eliminate the problem.
2) If the leaf cannot be reinforced, decrease the working time so that the clutch
slides as little as possible.
3) If the disks are bright, restore them with sandpaper or, if necessary, replace them.
13) THE CONTROLS
With the automation the gate has a power driven opening and closing. The controls can come in various forms (i.e. manual, remote controlled, limited access by
magnetic badge, etc.) depending on needs and installation characteristics. For
details on the various command systems, consult the specific instruction booklets.
Anyone using the automation must be instructed on its operation and controls.
14) MAINTENANCE
All maintenance operations must be performed with the system power supply shut off.
Lubricate periodically the articulated elements of the drive arm.
Clean the optical system of the photocells every now and then.
Have the adjustment of the electric clutch checked by a qualified specialist
(installer).
For any malfunction that remains unsolved, shut off the power to the system and
call a qualified specialist (installer).
123
15) TROUBLESHOOTING
15.1) The gate does not open. The motor runs, but the opening movement
does not start.
1) Check if the electric lock works correctly.
2) Check if the mechanical arrangement of the gate is faulty, e.g. there are interferences with the gate stop limits or between the edges of the leaves.
Fig. 1
Fig. 2
D811007_03
Fig. 3
AUTOMATION FOR SWING GATES
E5
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
124
AUTOMATION FOR SWING GATES
Fig. 12
E5
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
125
Fig. 21
D811007_03
Fig. 20
AUTOMATION FOR SWING GATES
E5
Fig. 22
Fig. 23
Fig. 24
Fig. 25
Fig. 26
D811007_03
126
AUTOMATION FOR SWING GATES
">