Techko S082X User's Manual

Add to my manuals
2 Pages

advertisement

Techko S082X User's Manual | Manualzz

SCREW HOLE

TEMPLATE

MODE S082KA

SCREW HOLE

SCREW HOLE

TESTING

ALARM OUTPUT AND PANIC BUTTON TEST

To test the alarm output, press the PANIC button located on front of the unit. (THIS UNIT IS VERY LOUD, COVER THE

SIREN ON THE FRONT OF THE UNIT BEFORE ACTIVATING).

The unit will immediately sound a piercing alarm siren. To disarm the unit, enter your security code followed by the

#ON/OFF button. (If you have not entered a security code the default is 0 and S082K is 5

CHIME TESTING

1.Set the function switch to the CHIME position.

2.Enter the security code followed by the #ON/OFF button,

the ALARM LED will illuminate. If this does not happen

repeat steps 1 and 2.

3.Close the door and then open it again, a pleasant chime will

sound 3 times.

4.To disarm the unit, enter the security code followed by the

#ON/OFF button.

5.As long as the unit is in the ARM mode, the chime will

continue to sound until DISARMED .

ALARM TESTING

1.Set the function switch to the INSTANT or DELAY

position.

2. Enter the security code followed by the #ON/OFF button,

the ARM LED will turn on. If this does not happen, repeat

steps 1 and 2.

3. Close the door and open it again in INSTANT mode, the

alarm sounds immediately. If the alarm is in DELAY mode,

the alarm will emit a low beep tone to alert your to disarm the

unit, if not disarmed, the unit will then sound a piercing alarm.

4.To disarm the unit, enter the security code followed by the

#ON/OFF button.

Note: in both modes, CHIME or ALARM (instant / delay) the unit will continue to

sound until DISARMED . The unit will only sound the ALARM if ARMED in

the ALARM mode. If armed in the CHIME mode the unit will sound only the CHIME.

If function switch is changed after the unit has been activated, this will not alter the

sound being produced.

OPERATION

ALARM MODE

1.Before arming the unit slide the function switch to the

INSTANT/DELAY position.

2.To arm the S082X / S082K, enter the security code

followed by the #ON/OFF button, the ARM LED will

turn on. If this does not happen repeat steps 1 and 2.

3.INSTANT mode.

When an entry is detected. The alarm sounds

immediately. This is used to protect you when you

are at home.

4.DELAY mode.

This mode is used when you are leaving your home.

On your return, an entry alert beep tone will sound

to alert you to disarm the unit. If the unit is not

disarmed within10 seconds of entry, the alarm will

sound a110db (S082KA is 115db) alarm siren.

5.The 110db/115db alarm will sound for about 30/36

seconds, while the alarm is sounding or during the

entry alert time the security code can be entered to

disarm the unit.

6.To disarm the unit, enter the security code followed by

the #ON/OFF button.

C H I M E M O D E

1 . B e f o r e a c t i v a t i n g t h e c h i m e , s l i d e t h e f u n c t i o n s w i t c h

t o t h e C H I M E p o s i t i o n .

2 . E n t e r t h e s e c u r i t y c o d e f o l l o w e d b y t h e # O N / O F F b u t t o n .

3 . T h e A R M L E D w i l l i l l u m i n a t e t o v e r i f y t h e u n i t i s O N ,

f o l l o w e d b y a s h o r t b e e p . I f t h e A R M l i g h t d o e s n o t

i l l u m i n a t e t h i s i n d i c a t e d t h e u n i t i s O F F.

4 . T h e c h i m e w i l l s o u n d i f t h e r e i s a n e n t r y. T h e c h i m e w i l l

s o u n d f o r e a c h e n t r y u n t i l t h e u n i t i s t u r n e d O F F ( d i s a r m e d )

N O T E : T h e p o s i t i o n o f t h e f u n c t i o n s w i t c h d o e s n o t n e c e s s a r i l y i n d i c a t e t h e m o d e t h e u n i t i s i n

( C H I M E / I N S TA N T / D E L AY ) . E a c h t i m e b e f o r e a c t i v a t i n g t h e u n i t , s e t t h e f u n c t i o n s w i t c h t o t h e c o r r e c t p o s i t i o n f o r t h e m o d e d e s i r e d .

PANIC ALARM

T h e r e d PA N I C b u t t o n o n t h e f r o n t p a n e l a c t i v a t e s t h e

a l a r m d u r i n g a p o s s i b l e e m e r g e n c y.

1 . P r e s s t h e p a n i c b u t t o n . T h i s w i l l a c t i v a t e t h e 11 0 d b

( S 0 8 2 K A i s 11 5 d b ) a l a r m s i r e n .

2 . D i s a r m t h e PA N I C a l a r m , f o l l o w t h e s a m e p r o c e d u r e a s

y o u w o u l d t o D I S A R M t h e u n i t .

CAUTION

THE MAGNET GUARD IS EXTREMELY LOUD. FOR YOUR

SAFETY. NEVER PLACE THE UNIT CLOSE TO YOUR EARS.

TO TEST THE ALARM, DIRECT THE UNIT AWAY FROM YOU

AT ARMS LENGTH AND ACTIVATE.

PATENT PENDING NOTICE

THIS PRODUCT IS PROTECTED UNDER FEDERAL PATENT. TRADEMARK AND COPYRIGHT

LAWS AND LAWS PREVENTING UNFAIR COMPETITION. NO DUPLICATION OR SIMULATION OF

THIS PRODUCT IS PERMITTED EXCEPT BY WRITTEN AUTHORIZATION OF TECHKO, INC.

TECHKO AND THE CONFIGURATION OF THIS PRODUCT ARE TRADEMARKS OF TECHKO, INC.

COPYRIGHT 1992 TECHKO, INC. ALL RIGHTS RESERVED

Customer Service :

1-888-8TECHKO (1-888-883-2456)

Website: www.techkomaid.com

Mfg. By

9767 Research Drive

Irvine, CA 92618-4626

MADE IN CHINA

SAFETY SECURITY

MAGNET GUARD

MODEL S082X/S082K

S082KA

1 2

4 5

*

PANIC

#

3

S082K

S082X

7

*

1

4

2

5

8

0

9

#

3

6

S082X

OPERATION MANUL

TEMPLATE

MODE S082X

SCREW HOLE

SCREW HOLE

CHANGING A SECURITY CODE TO A NEW CODE

1.Enter the old security code number.

2.Press the* /CODE button.

3.Enter the new code(1 to 12 digits), (S082KA is 1 to 7).

4.Press the */CODE button, the unit will beepo nce to

confirm your new code has been entered.

S082X S082X

S082X S082X

SENSORS

ON DOOR

S082X S082X

1 2

4

*

PANIC

S082KA

1

4

2

*

PANIC

S082KA

1

4

2

*

PANIC

S082KA

SENSORS

ON WINDOW

Fig.2

MOUNTING

SELECT A MOUNTING LOCATION

NOTE: Before mounting the unit be sure to read theS AFETY

TIPSs ection at the beginning of the manual.

1.Apply double sided tape (included) to back of sensor switch

pair. Mount sensor without wire to the door or window.

Mount the sensors with wire to the door or window frame.

(Fig.2) Be sure the magnetic sensors are mounted no further

than a 1/4f rom each other.

2.Using the mounting plate as template, mark the screw hole

locations and drill two 1/4h oles. Tap the provided screw

anchor into place. (Fig.3)

3.Secure the mounting plate to the wall with the screws

provided.

4.Snap the alarm unit into place on the mounting plate.

AFFIX SELF

ADHESIVE

TAPE HERE

AFFIX SELF

ADHESIVE

TAPE HERE

KEY HOLE

FOR WALL

MOUNTING

Fig.3

INSTALLATION

BATTERY INSTALLATION

1.Remove screws from battery compartment located on the

bottom of the unit .(Fig.1)

2.Install 3 AAA batteries / 9V battery. (Not included).

NOTE:

When the batteries are installed for the first time or are replaced the security code will automatically default back to 0 (S082KA factory code is 5 ) and the LED indicator will illuminate. This unit will also be in the ARM mode. After installing the battery to disarm the unit press 0 / 5 and the #ON/OFF button. A short Confirming beep will sound and the LED light will go out to verify the unit has been disarmed.

ENTERING CODE TO ARM AND DISARM

NOTE:

The default for the security code is 0 (S082KA default

is 5 ). When the battery is replaced the unit will reset to the factory set code 0 / 5 .

1.Press the 0 / 5 button or the code that is currently in

memory.(New battery default is 0 / 5 ). If there is an

existing code use that in place of the 0 / 5 .

2.Press the #ON/OFF button, a confirming beep should be

heard.

3.If the wrong security code is entered there will be two tone beep , this is different from the single beep confirmation.

4.When the unit is armed the ARM LED will illuminate.

3x1.5V AAA 1x9V 6F22

PROGRAMMING

A SECURITY CODE

NOTE: The programmable security code can be a 1 to 12 digit code.

(S082KA is 1 to 7 digits). Shorter codes such as 1 to 4 digits are easy to remember, long codes can provide greater safety. DO NOT INCLUDE

A 0 IN YOUR CODE (S082X). DO NOT INCLUDE A 5 IN YOUR

CODE (S082KA).

TO PROGRAM A SECURITY CODE AFTER

BATTERY INSTALLATION

1.Press the 0 (S082KA is 5 ) button.

2.Press the */CODE button.

3.Enter the new code (1 to 12 digits), (S082KA is 1 to 7).

4.Press the */CODE button, the unit will beep once to confirm

your new code has been entered.

INTRODUCTION

Congratulations on your purchase of the TECHKO model

S082X/S082KA.The MAGNET GUARD provides detection of unwanted intruders in your home by detecting entry. This unit can be mounted on any door or window. Arming and disarming of the unit is done by entering a security code on the keypad.

FEATURES

* Requires no wiring or special installation.

* Built-in 110db (S082KA is 115db) alarm siren.

* Up to 12 (S082KA 7 digits) digits programmable

security codes.

* Alarm / chime switchable mode.

* 5-10 seconds entry alarm delay with alert beep tone.

* Magnetic sensor detects entry.

* Direct access PANIC button.

* 4.5V (3 1.5V AAA size) alkaline battery operation

(S082KA uses 9V battery) (Not included).

* Optional AC adaptor power operation for S082KA.

* 2 warning stickers for possible points of entry.

SAFETY TIPS

1.Read all installation and operation instructions

carefully before using.

2.Alarm siren is very loud, never put the unit close to

your ear.

3.Avoid rough handling.

4.Do not install alarm where it will be exposed directly to

sunlight or high humidity.

5.The unit can provide valuable protection for your home

and property if utilized properly. However, this unit can

not guarantee compete protection against burglary

or robbery. Therefore, TECHKO cannot be held liable for

loss or damage which could occur.

6.Keep this manual in a convenient location for future

reference.

advertisement