TRANSITION Networks E-FRL-MC04 (SC), (SM), (L) 10BASE-FL Transceiver User's Guide
Transition Networks E-FRL-MC04 is a media access unit (MAU) that connects the AUI port of any DTE, repeater, or other network device to an Ethernet™ 10BASE-FL device through either unshielded or shielded twisted-pair copper cable and an RJ-45 connector. It provides an AUI connector and a set of RX (receive) and TX (transmit) ST 10BASE-FL connectors to 850mn multimode fiber cable. The E-FRL-MC04 can be used to connect to a 10BASE-FL hub or a hub with an MII connector. It also supports both half-duplex (HDX) and full-duplex (FDX) data transmission.
광고
광고
COMPLIANCE INFORMATION
UL Listed
C-UL Listed (Canada)
CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 1999 TRANSITION Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A.
33030.E
AUI/10BASE-FL
Minneapolis, MN 55344 USA
Transceiver
E-FRL-MC04, E-FRL-MC04(SC),
E-FRL-MC04(SM), E-FRL-MC04(L)
USER’S GUIDE
The TRANSITION Networks E-FRL-MC04 transceiver is a media access unit (MAU) that connects the AUI port of any DTE, repeater, or other network device, either directly or through an AUI cable, to an Ethernet
™
10BASE-FL device through either unshielded or shielded twisted-pair copper cable and an RJ-45 connector.
Ethernet “
10BASE-FL Transceiver
RX
TX
E-FRL-MC04
Provides an AUI connector and a set of
RX (receive) and TX (transmit) ST
10BASE-FL connectors to 850mn
multimode fiber cable.
E-FRL-MC04(SC)
Provides an AUI connector and a set of
RX (receive) and TX (transmit) SC
10BASE-FL connectors to 850mn
multimode fiber cable.
E-FRL-MC04(SM)
Provides an AUI connector and a set of
RX (receive) and TX (transmit) ST
10BASE-FL connectors to 1300mn
singlemode fiber cable.
E-FRL-MC04(L)
Provides an AUI connector and a set of
RX (receive) and TX (transmit) ST
10BASE-FL connectors to 1300mn
multimode fiber cable.
E-FRL-MC04 in the Network . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . . . .4
Fault Isolation and Correction . . . . .5
Cable Specifications . . . . . . . . . . . . .6
Technical Specifications . . . . . . . . . .7
Compliance Information . . . . . . . . . .8
E-FRL-MC04 IN THE NETWORK
NOTE: AUI cable can be used to connect to the transceiver.
10BASE-Fl Hub
OR
OR
SQE = ON
SQE = ON
Hub with MII connector
SQE = OFF
TECHNICAL SPECIFICATIONS
Standards
Case Dimensions
Environment
Warranty
IEEE 802.3
2.8" x 1.75" x 0.75" (71mm x 43mm x 18mm)
Temperature:
Humidity
0-40°C (32° to 104° F )
10-90%, non condensing
Altitude
Lifetime
0-10,000 feet
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
AUI/10BASE-FL Transceiver Model:
Part Number: E-FRL-MC04, E-FRL-MC04(SC),E-FRL-MC04(SM),
E-FRL-MC04(L)
EMC Directive 89/336/EEC Regulation:
Purpose: To declare that the E-FRL-MC04 to which this declaration refers is in conformity with the following standards.
EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992;
EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
Stephen Anderson, Vice-President of Engineering
_August 11, 1999_____
Date
CABLE SPECIFICATIONS
The physical characteristics of the media cable must meet or exceed IEEE 802.3
specifications.
Fiber-Optic Interface
850nm M ULTIMODE
Fiber Optic Cable Recommended:
Fiber Optic Transmitter Power:
Fiber Optic Receiver Sensitivity:
Bit error rate:
Maximum Cable Distance:
1300nm M ULTIMODE
F iber Optic Cable Recommended:
Fiber Optic Transmitter Power:
Fiber Optic Receiver Sensitivity:
Bit error rate:
Maximum Cable Distance:
1300nm SINGLEMODE
Fiber Optic Cable Recommended:
Fiber Optic Transmitter Power:
Fiber Optic Receiver Sensitivity:
Bit error rate:
Maximum Cable Distance:
62.5 / 125 µm multimode fiber
Average: -15 dBm
Average :
≤
10-10
-33 dBm
2 kilometers (6,600 feet)
62.5 / 125 µm multimode fiber
Average: -17 dBm
Average: -35 dBm
≤
10-9
5 kilometers (16,500 feet)
9/125 micron single mode fiber
Average: -16 dBm
Average: -33 dBm
≤
10-10
20 kilometers (66,000 feet)
AUI (DB-15) Interface
Parameter
Transmit
Transmit threshold voltage level:
Transmit turn on delay:
Transmit steady propagation delay:
Transmit loop back start up delay:
Transmit turn off to data idle:
Minimum
-140mV
SQE test delay:
SQE test duration:
Receive
Receive turn on delay:
400ns
0.6 µ sec
0.5 µ sec
Receive steady propagation delay:
Differential output voltage (RX(-/+)):
15ns
(+/-)550mV
Differential output voltage (col(-/+)): (+/-)550mV
Differential output rise time (RX(-/+), col(-/+)): 4ns
Differential output fall time (RX(-/+), col(-/+)): 4ns
Collision
Time for SQE to deact. after collision:
Collision frequency:
450ns
8.5MHz
Collision pulse duty cycle:
SQE test delay:
Jabber activation delay:
40%
0.6 µ sec
20ms
Typical
-170mV
15ns
1.0 µ sec
50ns
50%
70ms
Maximum
-190mV
100ns
50ns
500ns
2100ns
1.6 µ sec
1.5 µ sec
350ns
(+/-)1200
(+-)1200
700ns
11.5MHz
60%
1.6 µ sec
150ms
INSTALLATION
Set Switches
Two (2) switches are located on the top of the transceiver.
SQE Off/SQE On: Selects SQE test function. Set to SQE On when connecting to IEEE 802.3
compliant repeaters. Set to SQE Off when connecting to other devices. er
SQE Off
HDX
SQE On
FDX
HDX/FDX: Selects either half-duplex (HDX) or full-duplex (FDX) data transmission. Set according to network installation.
Install Cable
NOTE: See page 6 for cable specifications.
1.
Locate or build 10BASE-FL compliant cables with male twostranded TX to RX connectors at both ends.
2.
Connect male TX and RX cable connectors at one end of cable to
TX and RX female connectors, respectively, on transceiver.
3.
Connect male TX and RX cable connectors at other end of cable to RX and TX connectors of 802.3 compliant fiber device..
Connect to Power
The E-FRL-MC04 is powered through the AUI connection.
OPERATION
After installation, the transceiver should function without operator intervention.
Status LEDs
Use the status LEDs to monitor transceiver operation in the network.
Jabber :
Collision:
Transmit:
Receive:
Link
Power:
Illuminated red LED indicates that unit is disabled.
Flashing or illuminated red LED indicates collisions.
Flashing or illuminated green LED indicates packet(s) are being transmitted.
Flashing or illuminated green LED indicates packet(s) are being received.
Illuminated green LED indicates the unit is receiving link pulses from a compliant device.
Illuminated green LED indicates connection to external power.
Jabber
Collisiion
Transmit
Receive
Link
Power
SQE
H
FAULT ISOLATION and CORRECTION
If the transceiver fails, determine the answers to the following questions:
1.
Is the power LED on the transceiver illuminated?
NO
• Verify that the transceiver is installed properly in the AUI port and that the device is powered ON.
• Contact Technical Support at (800) 260-1312 or at (800) LAN-
WANS.
YES
• Proceed to step 2.
2.
Is the Link LED illuminated?
NO
• Check the fiber cables for proper connection. (If possible, try a different pair of fiber cables.)
• Contact Technical Support at (800) 260-1312 or at (800) LAN-
WANS.
YES
• Proceed to step 3.
3.
Is the fiber cable connected properly?
NO
• Verify that TX and RX cables on transceiver are connected to RX and TX ports, respectively, on each device.
• Contact Technical Support at (800) 260-1312 or at (800) LAN-
WANS.
YES
• Contact Technical Support at (800) 260-1312 or at (800) LAN-
WANS.