ANTARES D811213 23-10-00 Vers. 02 CONTROL UNIT ANTARES 482 1) GENERAL SAFETY WARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or things. • The “Warnings” leaflet and “Instruction booklet” supplied with this product should be read carefully as they provide important information about safety, installation, use and maintenance. • Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon or polystyrene bags out of children’s reach. • Keep the instructions together with the technical brochure for future reference. • This product was exclusively designed and manufactured for the use specified in the present documentation. Any other use not specified in this documentation could damage the product and be dangerous. • The Company declines all responsibility for any consequences resulting from improper use of the product, or use which is different from that expected and specified in the present documentation. • Do not install the product in explosive atmosphere. • The construction components of this product must comply with the following European Directives: 89/336/EEC, 73/23/EEC and subsequent amendments. As for all non-EEC countries, the above-mentioned standards as well as the current national standards should be respected in order to achieve a good safety level. • The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures (door, gates etc.), as well as from any deformation which might occur during use. • The installation must comply with the provisions set out by the following European Directives: 89/336/EEC, 73/23/EEC and subsequent amendments. • Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any buffer batteries, if fitted. • Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance equal to or greater than 3mm. • Check that a differential switch with a 0.03A threshold is fitted just before the power supply mains. • Check that earthing is carried out correctly: connect all metal parts for closure (doors, gates etc.) and all system components provided with an earth terminal. • Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any danger caused by squashing, conveying and shearing. • Position at least one luminous signal indication device (blinker) where it can be easily seen, and fix a Warning sign to the structure. • The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers’ components are used. • Only use original parts for any maintenance or repair operation. • Do not modify the automation components, unless explicitly authorised by the company. • Instruct the product user about the control systems provided and the manual opening operation in case of emergency. • Do not allow persons or children to remain in the automation operation area. • Keep radio control or other control devices out of children’s reach, in order to avoid unintentional automation activation. • The user must avoid any attempt to carry out work or repair on the automation system, and always request the assistance of qualified personnel. • Anything which is not expressly provided for in the present instructions, is not allowed. 2) GENERAL OUTLINE Control unit with microprocessor especially designed to operate one or two controllers for sliding or swing gates with a power up to 500W. Self-diagnosis: Before each manoeuvre, the control unit performs a check of the operation relays and safety devices (photocells, rubber skirt, etc.). Appropriate Dip-switches and Trimmers in the control unit allow configuration and calibration of the same respectively. The functions of Dip-switches and Trimmers are described in the following paragraphs while their positions on the board are shown in the diagram of figure 1. The complete updating of the settings must be carried out when the gate is closed and the motor is off. Depending on the type of installation, ensure the necessary degree of protection using the most appropriate system, such as accessories code nos. 999 120 and 99 121. 3) TECHNICAL SPECIFICATIONS Power supply .............................................................................................. 230Vac±10% 50Hz (different voltages available on request) Mains/low tension insulation ....................................... > 2MOhm 500Vdc Mains/lt dielectric strength ......................................... 3750Vac / 1 minute Motor output current ....................................................................... 5A max Motor relay switching current ............................................................... 15A Max. motor power ............................................................................. 500W Power supply for accessories ................... 24Vac (0.5A max. absorption) Open-gate warning light .................................................... 24Vac 3W max Blinker ............................................................................ 230Vac 40W max Fuses ............................................................................................ see fig.1 4) TERMINAL BOARD CONNECTIONS Wires powered at different voltages must be physically separated, or suitably insulated with at least 1 mm extra insulation. The wires must be clamped by an extra fastener near the terminals, for example by bands. JP3 1-2 Power supply: 230Vac±10%, 50-60Hz (1 neutral, 2 phase see fig.1). 3-4-5 Motor 1 connection, terminals 3-5 motor operation and capacitor connection, terminal 4 common wire. 4-1 230Vac output for blinker (without pre-alarm). 6-7-8 Motor 2 connection, terminals 6-8 motor operation and capacitor connection, terminal 7 common wire. 7-1 Connection of electric lock mod. EBP. JP4 9-10 START button (n.o). 9-11 Stop button (n.c). If not used, leave jumped. 9-13 Opening limit switch (n.c). If not used, leave jumped. 9-14 Closing limit switch (n.c). If not used, leave jumped. 12-18 Return for checking safety devices. For connection see fig. 2. If not used, leave jumped (connection indicated with a broken line in fig.1). 15-16 24Vac output for power supply to accessories. 17-18 Output for power supply to safety devices (transmitters, photocells and rubber skirt). Note: Output active during operation only. 19-20 Antenna input for radio receiver board (20 braid, 19 signal). JP5 21-22 Radio channel second output (n.o) (with twin-channel receiver only). JP1 Connector for single and twin channel radio receiver board. SCAUX JP1 1-2 Blinker with pre-alarm (DIP 6 ON) or courtesy light (DIP 6 OFF). JP3 3-4 Output for gate-open warning light, 24Vac max. 3W. This light is off when the gate is closed and goes on when the gate is opening or is totally open. The light flashes when the gate is closing. 5 Photocell connection (see fig.2). JP4 7-8-9-10-11 Photocell connection (see fig.2). For connection to the mains use a multiple-pole cable with a minimum cross section of 3x1.5sq.mm. of the type indicated in the above-mentioned standard (by way of example, if the cable is not shielded it must be at least equivalent to H07 RN-F while, if shielded, it must be at least equivalent to H05 VV-F with a cross section of 3x1.5mm). 5) ACCESSORIES The control unit mod. ANTARES can be completed with the following accessories. SPL: Automatic adjustable thermostat for motor preheating (fig.3) with appropriate wiring diagram (fig.4). ME: 12Vac electric lock control board (fig.5) with appropriate wiring diagram (fig.6). CONTROL UNITS D811213_02 Thank you for buying this product. Our company is sure that you will be more than satisfied with the product’s performance. Carefully read the “Instruction Booklet” which is supplied together with this product, since they provide important information regarding the safety, installation, use and maintenance of the product. This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives: 98/37/EEC, 89/336/EEC, 73/23/EEC (amended by RL 91/263/EEC, 92/31/EEC and 93/68/EEC). WARNING When carrying out connection and installation operations always refer to the current legislation in force, as well as to good technical principles. Installation, cleaning, repairs and maintenance must be carried out by qualified personnel only. ANTARES 6) DIP-SWITCH SETTING (Fig.1) Dip-switch 1 and 3 Photocells (FCH) ON - Deactivates the operation of the photocell during opening and reverses the movement in the closing phase immediately when the photocell detects an object. OFF - If an obstacle obscures the photocell during the closing phase, the gate stops immediately; the gate re-opens after removal of the obstacle. If an obstacle obscures the photocell when the gate is opening it stops immediately and continues its opening stroke after the obstacle has been removed. Dip-switch 2 Impulse block (IBL). ON - Start impulse has no effect during opening. OFF - Start impulse during opening causes the stoppage of the gate; during closing instead, causes the stoppage of the gate with DIP5 OFF, or the reversal of running direction with DIP5 ON. Dip-switch 4 Automatic closing (TCA) ON - The gate closes automatically after the period of time set on trimmer TCA. OFF - Deactivates automatic closing. Dip-switch 5 2 or 4 step logic (2P/4P). ON - A start command given during closing causes the reversal of running direction (2 step logic). A start command given during opening causes the stoppage of the gate. OFF - A start command given while the gate is moving causes the stoppage of the gate; a subsequent command causes the reversal of running direction (4 step logic). Note: A START command given on opening stops the movement and operates the TCA according to the value set if Dip 4 is ON. N.B.: A START command given on opening has no effect with Dip 2 ON. Dip-switch 6 Configuration of output 1-2 of SCAUX. ON - Blinker with 3 second pre-alarm (if connected to SCAUX terminal). OFF - Courtesy light stays on for 90 seconds from last operation. 7) FUNCTIONS CONTROLLED BY THE TRIMMERS TW Adjusts operation time both on opening and closing. After this time has elapsed, the motor stops. If electrical limit switches are used, increase the time by a few seconds with respect to the M2 motor stopping time (adjustable from 1 to 120 sec). TCA Sets the dwell time after which the gate closes automatically (adjustable from 1 to 90 sec). DELAY Sets the delay time on closing of motor 2 (adjustable from 1 to 30 sec.) 8) LED FUNCTIONS The control unit mod. ANTARES is equipped with a series of leds which signal any possible malfunction of the plant. When operating correctly, the condition of the leds is as follows. 1)LD1 (CDR) Direction led: goes on when the gate is closing. 2)LD2 (STOP) Goes off when a stop command is given. 3)LD3 (START) Goes on when a START command is given. 4)LD4 (PHOT) Goes on before each manoeuvre and stays on for its entire manoeuvre time provided that the photocells are aligned; in the case of an obstacle, it switches off. Then, is goes off upon completion of the manoeuvre after closing. 5)LD5 (SW.O) Goes off when the gate is completely open provided that it is equipped with a limit switch. 6)LD6 (SW.C) Goes off when the gate is completely closed provided that it is equipped with a limit switch. 7)LD7 (MC1) Goes on when the motor 1 is running (on opening or closing). 8)LD8 (MC2) Goes on when the motor 2 is running (on opening or closing). D811213_02 9) CONNECTION TO SAFETY DEVICES Note: only use safety devices which can receive with a free changeover contact (refer to fig.2). To connect the photocells refer to the diagram in fig. 2 taking into account the number of pairs used: 1 pair box 2A, 2 pairs box 2B, 3 pairs box 2C, 4 pairs box 2D. If photocells are not used, leave the jumpers aligned between terminal 9 of ANTARES and 5 of SCAUX, and between terminal 12 and 18 of the ANTARES board (connections indicated with a broken line in fig.1). The connection of the infrared rubber skirt must be performed in the same way as for the photocells, i.e. by energizing the transmitter from terminal 17 and 18 (JP4) and the receiver from terminal 15 and 16 (JP4). CONTROL UNITS 483 ANTARES Fig. 1 JP1 C1 SINC (SCAUX n°5) C3 TW T1 SWC1 SWO1 STOP PHOT COM START U2 U3 JP5 21 22 24Vac NO NC NC NC CH2 ANT. 24Vac TX JP3 1 2 3 4 5 6 7 8 TCA U1 DELAY 3 4 6 7 5 4 3 8 3 2 4 24Vac 5 10 11 12 13 14 15 6 7 8 9 17 484 18 19 K4 Vedi figura 2 See fig. 2 Voir fig. 2 Siehe Abb. 2 Véase la fig. 2 Veja a figura 2 20 1 JP4 10 11 PHOT 16 9 10 11 N 15 16 230Vac SCA JP4 2 K1 L SINC 9 6 7 8 JP3 JP1 1 LD4 C27 SW.C ANTARES U4 5 LD6 LD2 LD3 LD8 LD7 LD1 2 SW.O EBP JP3 JP1 JP4 JP3 CDR MC1 MC2 ST. 1 FCH 2 IBL 3 FCH 4 TCA 5 2P/4P 6 ALL/LC LD5 ON K4 1 2 3 4 5 6 JP2 5A/F (230V) 10A/F (110V) K1 U6 40W max. K3 22 JP5 K2 C5 K3 21 K2 C8 K5 4 0.1A/T (230V) 0.2A/T (110V) 2 3 6 7 8 9 1011 M2 M1 STOP SCAUX JP2 Fig. 2 1 5 9 11 10 6 SCAUX 7 2 3 4 5 Rx 1 2 Tx 15 16 9 12 17 18 ANTARES 8 5 9 11 10 6 SCAUX 7 1 2 3 4 5 Rx 1 2 Tx 1 2 3 4 5 Rx 1 2 Tx 15 16 9 12 17 18 ANTARES 8 2A 2B C NO NC 1 2 3 4 5 24Vac 5 9 11 10 6 SCAUX 7 8 1 2 3 4 5 Rx 1 2 Tx 1 2 3 4 5 Rx 1 2 Tx 1 2 3 4 5 Rx 1 2 Tx 1 2 3 4 5 Rx 1 2 Tx 1 2 3 4 5 Rx 1 2 Tx 1 2 3 4 5 Rx 1 2 Tx 1 2 3 4 5 Rx 1 2 Tx 15 16 12 9 17 18 ANTARES 5 2C CONTROL UNITS 9 11 10 6 SCAUX 7 8 15 16 12 9 17 18 ANTARES 2D D811213_02 1 L 5 N 1 C2 JP4 10 11 12 13 14 15 16 17 18 19 20 9 ANTARES Fig. 3 Fig. 4 N C C M1 M2 ANTARES L 1 2 3 4 5 6 2 1 7 3 4 8 5 16 17 6 1 2 3 4 5 6 24Vac SPL SPL Fig. 5 Fig. 6 ANTARES 1 N 2 3 4 5 6 7 8 9 230Vac 230Vac 4 1 2 3 4 3 ME 10 11 12 13 14 15 L Elettroserratura 12V Electric lock 12V Electroserrure 12V Elektroschloss 12V Electrocerradura 12V Fechadura eléctrica 12V 2 ME 1 Fig. 7 SPL ANTARES D811213_02 Disponibilità di raccordi tubo - cassetta: CRTR (raccordo con tubo rigido) CRTL (raccordo con guaina flessibile) Available couplings connecting the pipes to the box: CRTR (coupling with rigid pipe) CRTL (coupling with flexible sheath) Disponibilité de raccords tube - boîte: CRTR (raccord avec tube rigide) CRTL (raccord avec tuyau souple) Erhältliche Rohrverschraubungen für Steuerungsgehäuse: CRTR (Verbindungsstück für starres Rohr) CRTL (Verbindungsstück für flexibles Rohr) Disponibilidad de uniones tubo - caja: CRTR (unión con tubo rígido) CRTL (unión con vaina flexible) Disponibilità di raccordi tubo - cassetta: CRTR (raccordo con tubo rigido) CRTL (raccordo con guaina flessibile) SCAUX ME Cavallotto di messa a terra U-link for earth connection Crampillon de mise à la terre Erdanschlussklemmen Perno de U de toma de tierra Cabo descarnado de ligação à terra CONTROL UNITS 485 ">
/
Download
Bare en venlig påmindelse. Du kan se dokumentet lige her. Men vigtigst af alt har vores AI allerede læst det. Den kan forklare komplekse ting i enkle vendinger, besvare dine spørgsmål på ethvert sprog og hjælpe dig med hurtigt at navigere selv de længste eller mest komplicerede dokumenter.
Annonce