advertisement
▼
Scroll to page 2
of
7
6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT R1 B1 B2 790–960 1710–2180 1710–2180 X X X 65° 65° 65° 2°–10° 0°–10° 0°–10° set by hand or by optional RCU (Remote Control Unit) 6-Port Antenna 790–960/1710–2180/1710–2180 65°/65°/65° 17.5/17.5/17dBi 2°–10°/0°–10°/0°–10°T Type No. 80010292V03 Lowband R1, connector 1– 2 Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression MHz dBi dBi 790 – 862 17.1 17.0 ± 0.3 790 – 960 824 – 894 17.3 17.2 ± 0.3 880 – 960 17.4 17.3 ± 0.3 ° 69 ± 1.1 68 ± 1.3 66 ± 1.1 dB > 26 > 27 > 28 dB > 25 > 25 > 27 dB > 14.0 > 14.5 > 12.5 dB < 2.0 < 2.0 < 2.5 ° 7.9 ± 0.3 7.6 ± 0.3 7.2 ± 0.3 ° 2.0 – 10.0 ° < 0.1 < 0.1 < 0.2 dB > 14 > 15 > 15 936.4880/b ngmn 04.19.01.01 Subject to alteration. Cross Polar Isolation dB > 30 Port to Port Isolation dB > 36 (R1 // B1, B2) Max. Effective Power W 400 (at 50 °C ambient temperature) per Port Max. Effective Power W 800 (at 50 °C ambient temperature) Port 1–2 Values based on NGMN-P-BASTA (version 9.6) requirements. All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected] 80010292V03 Page 1 of 4 6-Port Antenna Lower highband MHz dBi dBi 1710 – 1880 17.2 17.1 ± 0.4 1710 – 2180 1850 – 1990 17.3 17.2 ± 0.3 1920 – 2180 17.3 17.2 ± 0.4 ° 64 ± 2.6 62 ± 2.4 62 ± 2.9 dB > 29 > 29 > 26 dB > 31 > 30 > 29 dB > 12.0 > 12.5 > 11.5 dB < 0.5 < 1.0 < 1.0 ° 7.6 ± 0.4 7.2 ± 0.5 6.8 ± 0.6 ° 0.0 – 10.0 ° < 0.6 < 0.7 < 0.6 dB > 14 > 17 > 16 Cross Polar Isolation dB Port to Port Isolation dB Max. Effective Power W per Port Max. Effective Power W Port 3–4 Values based on NGMN-P-BASTA (version 9.6) requirements. Upper highband Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression 250 (at 50 °C ambient temperature) 500 (at 50 °C ambient temperature) B2, connector 5 – 6 MHz dBi dBi 1710 – 1880 16.7 16.5 ± 0.3 1710 – 2180 1850 – 1990 16.8 16.6 ± 0.3 1920 – 2180 17.0 16.8 ± 0.3 ° 66 ± 3.1 63 ± 4.0 61 ± 2.9 dB > 28 > 30 > 27 dB > 30 > 30 > 28 dB > 14.5 > 14.0 > 11.0 dB < 0.5 < 1.0 < 1.5 ° 7.6 ± 0.3 7.2 ± 0.4 6.9 ± 0.5 ° 0.0 – 10.0 ° < 0.4 < 0.5 < 0.6 dB > 16 > 16 > 16 Cross Polar Isolation dB Port to Port Isolation dB Max. Effective Power W per Port Max. Effective Power W Port 5–6 Values based on NGMN-P-BASTA (version 9.6) requirements. Page 2 of 4 80010292V03 > 30 > 36 (B1 // R1, B2) > 30 > 36 (B2 // R1, B1) 250 (at 50 °C ambient temperature) 500 (at 50 °C ambient temperature) All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected] 936.4880/b ngmn 04.19.01.01 Subject to alteration. Frequency Range Gain at mid Tilt Gain over all Tilts Horizontal Pattern: Azimuth Beamwidth Front-to-Back Ratio, Total Power, ± 30° Cross Polar Discrimination at Boresight Cross Polar Discrimination over Sector Azimuth Beam Port-to-Port Tracking Vertical Pattern: Elevation Beamwidth Electrical Downtilt continuously adjustable Tilt Accuracy First Upper Side Lobe Suppression B1, connector 3 – 4 6-Port Antenna Mechanical specifications Electrical specifications, all systems Impedance Ω 50 VSWR < 1.5 Return Loss dB > 14 Interband Isolation dB > 36 Passive Intermodulation dBc < –150 (2 x 43 dBm carrier) Polarization ° +45, –45 900 (at 50 °C ambient Max. Effective Power W temperature) for the Antenna Values based on NGMN-P-BASTA (version 9.6) requirements. Input Connector Position Adjustment Mechanism Wind load (at Rated N | lbf Wind Speed: 150 km/h) Max. Wind Velocity km/h mph Height / Width / Depth mm inches Category of Mounting Hardware Weight kg lb Packing Size mm inches Scope of Supply Accessories (order separately if required) Type No. Description Remarks mm | inches 85010002 85010003 85010008 1 clamp 1 clamp 1 downtilt kit Mast diameter: 110 – 220 | 4.3 – 8.7 Mast diameter: 210 – 380 | 8.3 – 15.0 Downtilt angle: 0° – 8° 6 x 7-16 female bottom 3x, Position bottom continuously adjustable Frontal: 665 | 149 Maximal: 730 | 164 200 124 2598 / 261 / 146 102.3 / 10.3 / 5.7 H (Heavy) 27.0 / 29.2 (clamps incl.) 59.5 / 64.3 (clamps incl.) 2902 / 284 / 184 114.3 / 11.2 / 7.2 Panel and 2 units of clamps for 42 – 115 mm | 1.7– 4.5 inches diameter 1) 2) 1) 9 | 0.4 2) 72 | 2.8 Weight approx. Units per kg | lb antenna 2.7 | 6.0 4.8 | 10.6 4.3 | 9.5 2 2 1 1.1 | 2.4 2 Mast diameter: 42 – 115 | 1.7 – 4.5 For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Wall mounting: No additional mounting kit needed. Material: Reflector screen: Weather-proof aluminum. Fiberglass housing: It covers totally the internal antenna components. Fiberglass material guarantees optimum performance with regards to stability, stiffness, UV resistance and painting. The color of the radome is light grey. All screws and nuts: Stainless steel. Grounding: The metal parts of the antenna including the mounting kit are DC grounded. The inputs 790 – 960 MHz and 1710 – 2180 MHz are also DC grounded. 2671 | 105.2 1 clamp 2633 | 103.7 936.4880/b ngmn 04.19.01.01 Subject to alteration. 738546 2598 | 102.3 Accessories (included in the scope of supply) Adjustment mechanism with integrated scale All dimensions in mm | inches All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected] 80010292V03 Page 3 of 4 6-Port Antenna Layout of interface: 167 | 6.6 * 145 | 5.7 49 | 1.9 46 | 1.8 108 | 4.3 146 | 5.7 * 35 | 1.4 60 | 2.4 167 | 6.6 184 | 7.2 261 | 10.3 * Bottom view * Dimensions refer to radome All dimensions in mm | inches Frequency range Array Connector 790 – 960 MHz 1710 – 2180 MHz 1710 – 2180 MHz R1 B1 B2 1–2 3–4 5–6 B2 B1 R1 Any previous data sheet issues have now become invalid. Page 4 of 4 80010292V03 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected] 936.4880/b ngmn 04.19.01.01 Subject to alteration. Correlation Table Mounting Hardware Clamp Included in the Scope of Supply Suitable for mast diameter (mm) [inches] (mm) [inches] Antenna – mast distance Material of clamp and screws Weight (kg) [lb] 42 – 115 [1.65 – 4.53] 20 – 25 [0.79 – 0.98] Hot-dip galvanized steel / stainless steel 1.1 [2.43] 100 [3.94] 40 [1.57] 40 [1.57] 72 [2.83] 20–25 [0.79–0.98] 152 [5.98] 15 2–1 4 4.53] 5– [1.6 M10 MA = 25 Nm 35 [1.38] M8 MA = 20 Nm 64 [2.52] 125 [4.92] 936.3920/c Subject to alteration. 20–25 [0.79–0.98] Please note: Kathrein does not recommend to use counter nuts. The additional nuts supplied are only meant as spares. All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected] All dimensions in mm and [inches] 738546 Page 1 of 1 General Instructions for Adjustment Mechanism Description of the adjustment mechanism (protective cap removed): 1 1 2 2 ➀ Adjustment wheel with twist-lock function. ➁ Downtilt spindle with integrated scale. ➀ Thread for fixing the protective cap or the RCU (Remote Control Unit). ➁ Gearwheel for RCU power drive. To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gearwheel must be used for alignment. Manual adjustment procedure: 0° – max.° 0° – max.° Remove the protective cap. Set downtilt angle by rotating the adjustment wheel. Screw on the protective cap again. 936.4137 Subject to alteration. Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment: For a description of RCU installation please refer to the respective data sheet. Page 1 of 2 Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected] General Instructions for Feederline Installation for Triple-band Antennas Please note: To avoid any damage to the interfaces, please ensure that only suitable tools are used. To tighten the feederline connector interfaces, we strongly recommend using a special Kathrein installation tool (as shown below) in combination with a standard torque-wrench. Description of bottom end cap (exemplary picture): 7 Ventilation hole Adjustment mechanism (protective cap removed) 8 9 Spindle with tilting scale 6 1 2 5 3 4 7-16 female (long neck) Color coding: Correlation of each RF input to: – the corresponding adjustment mechanism – the frequency range – the polarization There are six feederline connectors and three adjustment mechanisms located at the bottom of the antenna. Installation of the feederline connector and RCU (optional): In order to protect the adjustment mechanism the protective caps have to be attached during feederline installation! Kathrein installation set: Type No. 85010005 Set has to be ordered separately! Set consists of two spanners of 27 and 32 mm width. Use a torque-wrench to finish installation (see installation tool). After feederline installation, the optional remote control units (RCU) 7, 8, 9 can be mounted if required. For a full description of RCU installation please refer to the respective data sheet. 27 or 32 mm These tools are suitable for 7-16 connectors with a wrench size of 27 or 32 mm. Tighten nut within a torque range of 25 – 33 Nm depending on connector manufacturers’ specifications. Repeat operations as shown for each feederline! Page 2 of 2 All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected] 936.4137 The sequence for installation is: feederline no. 1, 2, 3, 4, 5, 6. Carefully put the connector in place and hand-screw the nut. Subject to alteration. 1/2ßsquare actuation according to DIN 3120 Form C
advertisement
Related manuals
advertisement