Alcatel-Lucent OmniSwitch 6850E Series User guide

Add to My manuals
182 Pages

advertisement

Alcatel-Lucent OmniSwitch 6850E Series User guide | Manualzz

Part No. 060365-00, Rev. A

January 2013

OmniSwitch 6850E Series

Hardware Users Guide

www.alcatel-lucent.com

This user guide documents OmniSwitch 6850E Series hardware, including chassis and associated components for the 6.4.5.R02 Release.

The specifications described in this guide are subject to change without notice.

Copyright © 2013 by Alcatel-Lucent. All rights reserved. This document may not be reproduced in whole or in part without the express written permission of Alcatel-Lucent.

Alcatel-Lucent

®

and the Alcatel-Lucent logo are registered trademarks of Alcatel-Lucent. Xylan

®

,

OmniSwitch

®

, OmniStack

®

, and Alcatel-Lucent OmniVista

®

are registered trademarks of Alcatel-Lucent.

OmniAccess™, Omni Switch/Router™, PolicyView™, RouterView™, SwitchManager™, VoiceView™,

WebView™, X-Cell™, X-Vision™, and the Xylan logo are trademarks of Alcatel-Lucent.

This OmniSwitch product contains components which may be covered by one or more of the following

U.S. Patents:

•U.S. Patent No. 6,339,830

•U.S. Patent No. 6,070,243

•U.S. Patent No. 6,061,368

•U.S. Patent No. 5,394,402

•U.S. Patent No. 6,047,024

•U.S. Patent No. 6,314,106

•U.S. Patent No. 6,542,507

•U.S. Patent No. 6,874,090

26801 West Agoura Road

Calabasas, CA 91301

(818) 880-3500 FAX (818) 880-3505 [email protected]

US Customer Support—(800) 995-2696

International Customer Support—(818) 878-4507

Internet—service.esd.alcatel-lucent.com

Contents

About This Guide

........................................................................................................................................... vii

Supported Platforms ......................................................................................................... vii

Who Should Read this Manual? ........................................................................................ ix

When Should I Read this Manual? .................................................................................... ix

What is in this Manual? ..................................................................................................... ix

What is Not in this Manual? .............................................................................................. ix

How is the Information Organized? ................................................................................... x

Documentation Roadmap ................................................................................................... x

Related Documentation .................................................................................................... xii

Published / Latest Product Documentation ..................................................................... xiii

Technical Support ........................................................................................................... xiii

Chapter 1

Chapter 2

OmniSwitch 6850E Series ......................................................................................... 1-1

Availability Features ....................................................................................................... 1-2

OmniSwitch 6850E Series Chassis and Hardware Components

................... 2-1

OmniSwitch 6850E-24..................................................................................................... 2-3

OS6850E-24 Specifications ..................................................................................... 2-4

OmniSwitch 6850E-P24................................................................................................... 2-6

OS6850E-P24 Specifications ................................................................................... 2-7

OmniSwitch 6850E-24X .................................................................................................. 2-9

OS6850E-24X Specifications ................................................................................ 2-10

OmniSwitch 6850E-P24X ............................................................................................. 2-12

OS6850E-P24X Specifications .............................................................................. 2-13

OmniSwitch 6850E-48................................................................................................... 2-15

OS6850E-48 Specifications ................................................................................... 2-16

OmniSwitch 6850E-P48................................................................................................. 2-18

OS6850E-P48 Specifications ................................................................................. 2-19

OmniSwitch 6850E-48X ................................................................................................ 2-21

OS6850E-48X Specifications ................................................................................ 2-22

OmniSwitch 6850E-P48X.............................................................................................. 2-24

OS6850E-P48X Specifications .............................................................................. 2-25

OmniSwitch 6850E-U24X ............................................................................................. 2-27

OS6850E-U24X Specifications .............................................................................. 2-28

OmniSwitch 6850E LED Status Indicators ................................................................... 2-31

OmniSwitch 6850E Series Hardware Users Guide

January 2013

iii

Chapter 3

Chapter 4

iv

Contents

Mounting the Switch ..................................................................................................... 2-32

Chassis Airflow ...................................................................................................... 2-33

Installing the Switch on a Tabletop or Bench ........................................................ 2-35

Rack-Mounting the Switch ..................................................................................... 2-36

Setting Up a Stacked Configuration .............................................................................. 2-38

Redundant Stacking Cable Connections ................................................................ 2-38

Supported Cabling Patterns .................................................................................... 2-38

Booting OmniSwitch 6850E Series Switches ............................................................... 2-41

Power Cords .................................................................................................................. 2-43

Console Port .................................................................................................................. 2-44

10/100 Ethernet Port – RJ-45 Pinout (non-PoE) .................................................... 2-46

Gigabit Ethernet Port – RJ-45 Pinout ..................................................................... 2-46

10/100/1000 Mbps Power over Ethernet Port – RJ-45 Pinout .............................. 2-46

RJ-45 Console Port – Connector Pinout ................................................................ 2-47

Dying Gasp .................................................................................................................... 2-48

SNMP Trap ............................................................................................................ 2-48

Syslog Message ...................................................................................................... 2-48

Link OAM PDU ..................................................................................................... 2-49

OmniSwitch 6850E Series Power Supplies

.......................................................... 3-1

OmniSwitch 6850E Series Power Supplies .................................................................... 3-2

Connecting a Power Supply Directly to the Chassis ................................................ 3-9

Connecting a Power Supply with a Cable .............................................................. 3-10

DC Power Supply Considerations .......................................................................... 3-14

Installing DC Power Source Wire Leads ............................................................... 3-16

Viewing the Power Supply Status .......................................................................... 3-18

Monitoring the Chassis ................................................................................................. 3-19

OmniSwitch Backup Power Shelf/System (BPS) ................................................. 4-1

Chassis Details ................................................................................................................ 4-2

Supported Platforms ........................................................................................................ 4-2

Specifications .................................................................................................................. 4-3

Considerations if OS-BPS is the Only Power Source In a Stack ............................. 4-4

Chassis Status LEDs ....................................................................................................... 4-4

Mounting the Chassis ...................................................................................................... 4-6

OmniSwitch BPS Airflow ........................................................................................ 4-7

Rack-Mounting ............................................................................................................... 4-9

Power Supplies .............................................................................................................. 4-13

AC Power Supply LED States ............................................................................... 4-14

OmniSwitch BPS PoE Power Supply LED States ................................................. 4-16

OmniSwitch BPS Power Connections .......................................................................... 4-17

Grounding the Chassis .................................................................................................. 4-21

Disconnecting a Chassis from the OS-BPS .................................................................. 4-22

OmniSwitch 6850E Series Hardware Users Guide

January 2013

Contents

Chapter 5

Chapter 6

Monitoring OmniSwitch BPS Components .................................................................. 4-25

Viewing General Power Supply Information ......................................................... 4-25

OmniSwitch BPS Operation ......................................................................................... 4-26

Changing the OS-BPS Mode .................................................................................. 4-26

Supported Configurations ...................................................................................... 4-27

System Power Scenarios ........................................................................................ 4-28

Managing Power over Ethernet (PoE)

.................................................................. 5-1

In This Chapter ................................................................................................................ 5-2

Power over Ethernet Specifications ................................................................................ 5-3

Viewing PoE Power Supply Status ................................................................................. 5-4

Configuring Power over Ethernet Parameters ................................................................. 5-5

Setting the PoE Operational Status .......................................................................... 5-6

Configuring the Total Power Available to a Port ..................................................... 5-6

Configuring the Total Power Available to a slot ...................................................... 5-7

Setting Port Priority Levels ...................................................................................... 5-7

Setting the Capacitor Detection Method .................................................................. 5-8

Understanding Priority Disconnect ................................................................................. 5-9

Disabling Priority Disconnect .................................................................................. 5-9

Enabling Priority Disconnect ................................................................................... 5-9

Monitoring Power over Ethernet via CLI ..................................................................... 5-12

Managing OmniSwitch 6850E Series Stacks

...................................................... 6-1

In This Chapter ................................................................................................................ 6-2

OmniSwitch 6850E Series Stacking Specifications ........................................................ 6-3

OmniSwitch 6850E Series Stack Overview .................................................................... 6-4

Roles Within the Stack .................................................................................................... 6-4

Primary Management Module Selection .................................................................. 6-7

Secondary Management Module Selection ............................................................ 6-10

Recovering from Pass-Through Mode (Duplicate Slot Numbers) ......................... 6-14

Stack Cabling ................................................................................................................ 6-17

Slot Numbering ............................................................................................................. 6-20

Reverting to the Dynamic Slot Numbering Model ................................................ 6-24

Hot-Swapping Modules In a Stack ............................................................................... 6-25

Reloading Switches ....................................................................................................... 6-27

Software Synchronization During a Full Reload ................................................... 6-32

Effects of Saved Slot Number Information on the Reload Process ....................... 6-32

Changing the Secondary Module to Primary ................................................................ 6-35

Synchronizing Switches in a Stack ............................................................................... 6-37

Monitoring the Stack ..................................................................................................... 6-38

OmniSwitch 6850E Series Hardware Users Guide

January 2013

v

Appendix A

Index

Contents

Regulatory Compliance and Safety Information

A-1

Declaration of Conformity: CE Mark ............................................................................ A-1

China RoHS: Hazardous Substance Table ..................................................................... A-2

Standards Compliance .................................................................................................... A-4

NEBS Compliance Statements ....................................................................................... A-5

Intended Installation Locations ........................................................................ A-5

Battery Return Configuration ........................................................................... A-5

Equipment Grounding ...................................................................................... A-5

Translated Safety Warnings ........................................................................................... A-8

Chassis Lifting Warning ................................................................................... A-8

Blank Panels Warning ...................................................................................... A-8

Electrical Storm Warning ................................................................................. A-8

Installation Warning ......................................................................................... A-9

Invisible Laser Radiation Warning ................................................................... A-9

Operating Voltage Warning ............................................................................. A-9

Power Disconnection Warning ....................................................................... A-10

Proper Earthing Requirement Warning .......................................................... A-10

DC Power Supply Connection Warning ...................................................................... A-11

Read Important Safety Information Warning ................................................. A-11

Restricted Access Location Warning ............................................................. A-11

Wrist Strap Warning ....................................................................................... A-12

Instrucciones de seguridad en español ......................................................................... A-13

Advertencia sobre el levantamiento del chasis ............................................... A-13

Advertencia de las tapaderas en blanco .......................................................... A-13

Advertencia en caso de tormenta eléctrica ..................................................... A-13

Advertencia de instalación ............................................................................. A-13

Advertencia de radiación láser invisible ......................................................... A-13

Advertencia de la batería de litio .................................................................... A-13

Advertencia sobre la tensión de operación ..................................................... A-13

Advertencia sobre la desconexión de la fuente .............................................. A-13

Advertencia sobre una apropiada conexión a tierra ....................................... A-14

Leer “información importante de seguridad” ................................................. A-14

Advertencia de acceso restringido .................................................................. A-14

Advertencia de pulsera antiestática ................................................................ A-14

Clase de seguridad .......................................................................................... A-14

Advertencia de fuentes de poder .................................................................... A-14

.................................................................................................................................. Index-1 vi OmniSwitch 6850E Series Hardware Users Guide

January 2013

About This Guide

This OmniSwitch 6850E Series Hardware Users Guide describes your switch hardware components and basic switch hardware procedures.

Supported Platforms

This information in this guide applies to the following products:

OmniSwitch 6850E-24/P24/24X/P24X

OmniSwitch 6850E-48/P48/48X/P48X

OmniSwitch 6850E-U24X

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page vii

Supported Platforms

Unsupported Platforms

The information in this guide does not apply to the following products:

OmniSwitch (original version with no numeric model name)

OmniSwitch 6600 Family

OmniSwitch 6800 Series

OmniSwitch 6850 Series

OmniSwitch 7700

OmniSwitch 7800

OmniSwitch 8800

OmniSwitch 9000 Series

OmniStack

OmniAccess

About This Guide page viii OmniSwitch 6850E Series Hardware Users Guide

January 2013

About This Guide Who Should Read this Manual?

Who Should Read this Manual?

The audience for this users guide is network administrators and IT support personnel who need to configure, maintain, and monitor switches and routers in a live network. However, anyone wishing to gain knowledge on the OmniSwitch 6850E Series hardware will benefit from the material in this guide.

When Should I Read this Manual?

Read this guide as soon as you are ready to familiarize yourself with your switch hardware components.

You should have already stepped through the first login procedures and read the brief hardware overviews in the OmniSwitch 6850E Series Getting Started Guide.

You should already be familiar with the very basics of the switch hardware, such as module LEDs and module installation procedures. This manual will help you understand your switch hardware components

(e.g., chassis, stacking and cables, backup power supplies, etc.) in greater depth.

What is in this Manual?

This users guide includes the following hardware-related information:

Descriptions of stand-alone and stacked configurations.

Descriptions of “availability” features.

Descriptions of chassis types.

Instructions for mounting the chassis.

Descriptions of hardware components (status LEDs, chassis, stacking and cables, backup power supplies, etc.).

Managing a stand-alone chassis.

Setting up stacks.

Managing stacks.

Hardware-related Command Line Interface (CLI) commands

What is Not in this Manual?

The descriptive and procedural information in this manual focuses on switch hardware. It includes information on some CLI commands that pertain directly to hardware configuration, but it is not intended as a software users guide. There are several users guides that focus on switch software configuration. Consult those guides for detailed information and examples for configuring your switch software to operate in a

live network environment. See “Documentation Roadmap” on page -x and

“Related Documentation” on page -xii

for further information on software configuration guides available for your switch.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page ix

How is the Information Organized?

About This Guide

How is the Information Organized?

This users guide provides an overview of OmniSwitch 6850E Series switches, an overview and procedures for setting up and managing the switches, an overview and procedures for managing Power over

Ethernet (PoE), and an overview and procedures for managing stacks.

Documentation Roadmap

The OmniSwitch user documentation suite was designed to supply you with information at several critical junctures of the configuration process.The following section outlines a roadmap of the manuals that will help you at each stage of the configuration process. Under each stage, we point you to the manual or manuals that will be most helpful to you.

Stage 1: Using the Switch for the First Time

Pertinent Documentation: OmniSwitch 6850E Series Getting Started Guide

Release Notes

The OmniSwitch 6850E Series Getting Started Guide provides all the information you need to get your switch up and running the first time. This guide provides information on unpacking the switch, rack mounting the switch, installing stacking cables, installing backup power supplies, unlocking access control, setting the switch’s IP address, setting up a password, and setting up stacks. It also includes succinct overview information on fundamental aspects of the switch, such as hardware LEDs, the software directory structure, stacking, CLI conventions, and web-based management.

At this time you should also familiarize yourself with the Release Notes that accompanied your switch.

This document includes important information on feature limitations that are not included in other user guides.

Stage 2: Gaining Familiarity with Basic Switch Functions

Pertinent Documentation: OmniSwitch 6850E Series Hardware Users Guide

OmniSwitch AOS Release 6 Switch Management Guide

Once you have your switch up and running, you will want to begin investigating basic aspects of its hard ware and software. Information about switch hardware is provided in the OmniSwitch 6850E Series Hardware Users Guide. This guide provide specifications, illustrations, and descriptions of all hardware components—e.g., chassis, stacking and stacking cables, backup power supplies, etc. It also includes steps for common procedures, such as removing and installing switch modules.

The OmniSwitch AOS Release 6 Switch Management Guide is the primary user guide for the basic software features on a single switch. This guide contains information on the switch directory structure, basic file and directory utilities, switch access security, SNMP, and web-based management. It is recommended that you read this guide before connecting your switch to the network.

page x OmniSwitch 6850E Series Hardware Users Guide

January 2013

About This Guide Documentation Roadmap

Stage 3: Integrating the Switch Into a Network

Pertinent Documentation: OmniSwitch AOS Release 6 Network Configuration Guide

OmniSwitch AOS Release 6 Advanced Routing Configuration Guide

When you are ready to connect your switch to the network, you will need to learn how the OmniSwitch implements fundamental software features, such as 802.1Q, VLANs, and Spanning Tree. The OmniSwitch

AOS Release 6 Network Configuration Guide contains overview information, procedures and examples on how standard networking technologies are configured on the OmniSwitch.

The OmniSwitch AOS Release 6 Advanced Routing Configuration Guide includes configuration information for networks using Open Shortest Path First (OSPF).

Anytime

The OmniSwitch CLI Reference Guide contains comprehensive information on all CLI commands supported by the switch. This guide includes syntax, default, usage, example, related CLI command, and

CLI-to-MIB variable mapping information for all CLI commands supported by the switch. This guide can be consulted anytime during the configuration process to find detailed and specific information on each

CLI command.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page xi

Related Documentation About This Guide

Related Documentation

The following are the titles and descriptions of all the OmniSwitch 6850E Series user manuals:

OmniSwitch 6850E Series Getting Started Guide

Describes the hardware and software procedures for getting an OmniSwitch 6850E Series switch up and running. Also provides information on fundamental aspects of OmniSwitch software and stacking architecture.

OmniSwitch 6850E Series Hardware Users Guide

Detailed technical specifications and procedures for the OmniSwitch 6850E Series chassis and components. This manual also includes comprehensive information on assembling and managing stacked configurations.

OmniSwitch CLI Reference Guide

Complete reference to all CLI commands supported on the OmniSwitch. Includes syntax definitions, default values, examples, usage guidelines and CLI-to-MIB variable mappings.

OmniSwitch AOS Release 6 Switch Management Guide

Includes procedures for readying an individual switch for integration into a network. Topics include the software directory architecture, image rollback protections, authenticated switch access, managing switch files, system configuration, using SNMP, and using web management software (WebView).

OmniSwitch AOS Release 6 Network Configuration Guide

Includes network configuration procedures and descriptive information on all the major software features and protocols included in the base software package. Chapters cover Layer 2 information

(Ethernet and VLAN configuration), Layer 3 information (routing protocols, such as RIP), security options (authenticated VLANs), Quality of Service (QoS), and link aggregation.

OmniSwitch AOS Release 6 Advanced Routing Configuration Guide

Includes network configuration procedures and descriptive information on all the software features and protocols included in the advanced routing software package. Chapters cover multicast routing

(DVMRP and PIM-SM), and OSPF.

OmniSwitch Transceivers Guide

Includes transceiver specifications and product compatibility information.

Technical Tips, Field Notices

Includes information published by Alcatel-Lucent’s Customer Support group.

Release Notes

Includes critical Open Problem Re, feature exceptions, and other important information on the features supported in the current release and any limitations to their support.

page xii OmniSwitch 6850E Series Hardware Users Guide

January 2013

About This Guide Published / Latest Product Documentation

Published / Latest Product Documentation

All user guides are included on the Alcatel-Lucent public website. This website also includes user guides for other Alcatel-Lucent Enterprise products.

The latest user guides can be found on our website at: http://enterprise.alcatel-lucent.com/?dept=UserGuides&page=Portal

Technical Support

An Alcatel-Lucent service agreement brings your company the assurance of 7x24 no-excuses technical support. You’ll also receive regular software updates to maintain and maximize your Alcatel-Lucent product’s features and functionality and on-site hardware replacement through our global network of highly qualified service delivery partners. Additionally, with 24-hour-a-day access to Alcatel-Lucent’s Service and Support web page, you’ll be able to view and update any case (open or closed) that you have reported to Alcatel-Lucent’s technical support, open a new case or access helpful release notes, technical bulletins, and manuals. For more information on Alcatel-Lucent’s Service Programs, see our web page at service.esd.alcatel-lucent.com, call us at 1-800-995-2696, or email us at [email protected].

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page xiii

Technical Support About This Guide page xiv OmniSwitch 6850E Series Hardware Users Guide

January 2013

1 OmniSwitch 6850E Series

The OmniSwitch 6850E Series are an advanced fixed configuration family of stackable Ethernet switches.

These switches provide wire rate layer-2 forwarding and layer-3 routing with advanced services, effective availability, resiliency, and security features and are ideal for the following network applications:

Enterprise workgroups/LAN wiring closets

Edge deployments and branch offices

L3 aggregation/distribution layer switches in three-tier networks

Small enterprise core switching

Quality of service (QoS) for mission critical applications

Data center server clusters

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 1-1

Availability Features OmniSwitch 6850E Series

Availability Features

The switch provides a broad variety of availability features. Availability features are hardware and software-based safeguards that help to prevent the loss of data flow in the unlikely event of a subsystem failure. In addition, some availability features allow users to maintain or replace hardware components without powering off the switch or interrupting switch operations. Combined, these features provide added resiliency and help to ensure that the switch or virtual chassis is consistently available for day-to-day network operations.

Hardware-related availability features include:

Software Rollback

Backup Power Supplies

Hot Swapping

Hardware Monitoring

Software Rollback

Software rollback (also referred to as image rollback) essentially allows the OmniSwitch to return to a prior “last known good” version of software in the event of a system software problem. The switch controls software rollback through its resilient directory structure design (i.e., /flash/working and /flash/ certified).

For detailed information on the software rollback feature, as well as the switch’s /flash/working and

/flash/certified directories, refer to the “Managing CMM Directory Content” chapter in the OmniSwitch

AOS Release 6 Series Switch Management Guide.

Backup Power Supplies

The switches support an optional backup power supply. This power supply is connected to the rear of the unit and provides redundant chassis power on a 1:1 basis. There is a power shelf provided with the unit that slides into the rear of the chassis and is used to hold the power supplies.

Backup power supplies operate in active standby mode. If the primary power supply fails unexpectedly, the backup power supply automatically takes up the full power load without disrupting the switch.

page 1-2 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Availability Features

Hot Swapping

Hot swapping refers to the action of adding, removing, or replacing components without powering off switches or disrupting other components.This feature facilitates hardware upgrades and maintenance and allows users to easily replace components in the unlikely event of hardware failure.

The following hardware components can be hot swapped:

Backup power supply

Backup power supply connector cables

Transceivers

For instructions on hot swapping backup power supplies, refer to Chapter 2, “OmniSwitch 6850E Series

Chassis and Hardware Components.”

.

Note: The OmniSwitch 6850E chassis fans are not hot swappable or field replaceable. If there is a failure of any of the fans the entire chassis must be replaced. Please contact Service & Support for chassis replacement instructions. Replacement time is typically 5 days with expedited service available.

Hardware Monitoring

Automatic Monitoring

Automatic monitoring refers to the switch’s built-in sensors that automatically monitor operations. If an error is detected (e.g., over-threshold temperature), the switch immediately sends a trap to the user. The trap is displayed on the console in the form of a text error message. (In the case of an over-threshold temperature condition, the chassis displays an amber TMP LED in addition to sending a trap.)

LEDs

LEDs, which provide visual status information, are provided on the chassis front panel. LEDs are used to indicate conditions such as hardware and software status, temperature errors, link integrity, data flow, etc.

For detailed LED descriptions, refer to Chapter 2, “OmniSwitch 6850E Series Chassis and Hardware

Components.”

User-Driven Monitoring

User-driven hardware monitoring refers to CLI commands that are entered by the user in order to access the current status of hardware components. The user enters “show” commands that output information to the console. Monitoring information for chassis components, such as the optional back up power supply, chassis temperature sensor, and chassis fans is provided in

Chapter 2, “OmniSwitch 6850E Series Chassis and Hardware Components.”

The show commands for all the features are described in detail in the

OmniSwitch CLI Reference Guide.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 1-3

Availability Features OmniSwitch 6850E Series page 1-4 OmniSwitch 6850E Series Hardware Users Guide

January 2013

2 OmniSwitch 6850E Series

Chassis and Hardware

Components

OmniSwitch 6850E Series Switches

OmniSwitch 6850E-24 (see

“OmniSwitch 6850E-24” on page 2-2 )

OmniSwitch 6850E-P24 (see

“OmniSwitch 6850E-P24” on page 2-5

)

OmniSwitch 6850E-24X (see “OmniSwitch 6850E-24X” on page 2-8

)

OmniSwitch 6850E-P24X (see

“OmniSwitch 6850E-P24X” on page 2-11 )

OmniSwitch 6850E-48 (see

“OmniSwitch 6850E-48” on page 2-14 )

OmniSwitch 6850E-P48 (see

“OmniSwitch 6850E-P48” on page 2-17

)

OmniSwitch 6850E-48X (see “OmniSwitch 6850E-48X” on page 2-20

)

OmniSwitch 6850E-P48X (see

“OmniSwitch 6850E-P48X” on page 2-23 )

OmniSwitch 6850E-U24X (see “OmniSwitch 6850E-U24X” on page 2-26 )

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-1

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-24

A B C D

O mniSwitch 6850E-C24

OK PRI PWR BP S

USB

E

CLAS S 1 LAS ER

PRODUCT

C onsole

R ear

R ear

F G

OS6850E-24 Front Panel

Item Description

A

B

C

D

E

F

G

LED Indicator

Seven segment LED provides stack element ID.

USB Port

High speed USB port.

System Status LEDs

Provides status on hardware, software, primary and redundant power.

10/100/1000BaseT RJ-45 Ports and LEDs

10/100/1000BaseT non-combo and 10/100/1000BaseT combo ports. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

SFP Combo Ports and LEDs

Combo SFP connectors for various supported SFP transceivers.

Console Port

RS-232 console port with an RJ-45 connector. Provides access to the CLI for configuration and management.

Rear Module Port LEDs

Provides link and traffic status for rear module.

Refer to “OmniSwitch 6850E LED Status Indicators” on page 2-31 for LED status information.

Refer to “OmniSwitch 6850E Port Numbering” on page 2-30 for port numbering.

page 2-2 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-24 Rear Panel

B

C

D

Item

A

B

C

OS6850E-24 Rear Panel

D

Description

Grounding Block

Type LCD8-10A-L grounding lug

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Primary Power Supply Connector

DB-25 connector for required external primary power supply.

Stacking/SFP+ Uplink Module

Connectors for use in stacking switches into a virtual chassis or as uplink ports.

A

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-3

OmniSwitch 6850E Series Chassis and Hardware Components

OS6850E-24 Specifications

Total non-combo 10/100/

1000Base-T ports

Total 10/100/1000Base-T or SFP combo ports

Maximum SFP+ ports

1

Maximum CX4 stacking ports

Per switch - 20

Per stack - 160

Per switch - 4

Per stack - 32

Per switch - 2

Per stack - 16 (Note: All used for stacking)

Per switch - 2

Per stack - 16

Power

Flash memory size

RAM memory size

Width

Height

Height (rack units)

Depth

Weight

See “OmniSwitch 6850E Series Power Supplies” on page 3-2

128 MB

512 MB SDRAM

17.32 in. (44.0 cm)

1.73 in. (4.4 cm)

1 RU

10.59 in. (26.9 cm)

8.36 lbs.(3.79 kg)

Relative Humidity

Ambient Temperature

Altitude

Operating: 5% to 95% (non-condensing)

Storage: 5% to 95% (non-condensing)

Operating: 32º F to 113º F (0 ºC to 45 ºC)

Storage: 14º F to 158º F (-10 ºC to 70 ºC)

Operating: Up to 10,000 ft. (3048 m)

Storage: Up to 40,000 ft. (12192 m)

9216 bytes Maximum frame size

Ethernet standards 802.3i (10BaseT), Cable: (Cat 5 UTP)

802.3u (100BaseTX), Cable: (Cat 5e/6 UTP, EIA/TIA 568)

802.3ab (1000Base-T), Cable: (Cat -5e/6, UTP, EIA/TIA 568)

802.3z (1000Base-X), Cable: (SMF, MMF)

802.3ah (EFM), Cable: (SMF, MMF)

Maximum cable distance (RJ-45) 100 meters

1. Two SFP+ ports are provided with a plug-in module that replaces the CX4 plug-in module.

page 2-4 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-P24

A B C

O mniSwitch 6850E-P24

OK PRI PWR BP S

USB

D E

CLAS S 1 LAS ER

PRODUCT

C onsole

R ear

R ear

F G

OS6850E-P24 Front Panel

Item Description

A

B

C

D

E

F

G

LED Indicator

Seven segment LED provides stack element ID.

USB Port

High speed USB port.

System Status LEDs

Provides status on hardware, software, primary and redundant power.

10/100/1000BaseT RJ-45 PoE Ports and LEDs

10/100/1000BaseT non-combo and 10/100/1000BaseT combo ports. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

SFP Combo Ports and LEDs

Combo SFP connectors for various supported SFP transceivers. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

Console Port

RS-232 console port with an RJ-45 connector. Provides access to the CLI for configuration and management.

Rear Module Port LEDs

Provides link and traffic status for rear modules.

Refer to “OmniSwitch 6850E LED Status Indicators” on page 2-31 for LED status information.

Refer to “OmniSwitch 6850E Port Numbering” on page 2-30 for port numbering.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-5

OmniSwitch 6850E-P24 Rear Panel

OmniSwitch 6850E Series Chassis and Hardware Components

A B

B

C

D

E

Item

A

C D

OS6850E-P24 Rear Panel

E

Description

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Grounding Block

Type LCD8-10A-L grounding lug

Redundant Power Supply Connector

DB-25 connector for optional redundant power supply.

Primary Power Supply Connector

DB-25 connector for required primary power supply.

Stacking/SFP+ Uplink Module

Connectors for use in stacking switches into a virtual chassis or as uplink ports.

Note . The rear panel of the PoE models contain three DB-25 power supply connectors. One of the connectors is the for the primary power supply and two of the connectors are for the redundant power supplies. The primary power supply must be connected to the primary connector. A redundant power supply can be connected to either of the redundant connectors. page 2-6 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OS6850E-P24 Specifications

Total non-combo 10/100/

1000Base-T PoE ports

Total 10/100/1000Base-T PoE or

SFP combo ports

Total PoE ports (non-combo and combo)

Maximum SFP+ ports

1

Per switch - 20

Per stack - 160

Per switch - 4

Per stack - 32

Per switch - 24

Per stack - 192

Per switch - 2

Per stack - 16 (Note: All used for stacking)

Maximum CX4 stacking ports

Power

Flash memory size

RAM memory size

Width

Height

Height (rack units)

Depth

Weight

Relative Humidity

Per switch - 2

Per stack - 16

See

“OmniSwitch 6850E Series Power Supplies” on page 3-2

128 MB

512 MB SDRAM

17.32 in. (44.0 cm)

1.73 in. (4.4 cm)

1 RU

10.59 in. (26.9 cm)

Ambient Temperature

Altitude

8.55 lbs. (3.88 kg)

Operating: 5% to 95% (non-condensing)

Storage: 5% to 95% (non-condensing)

Operating: 32º F to 113º F (0 ºC to 45 ºC)

Storage: 14º F to 158º F (-10 ºC to 70 ºC)

Operating: Up to 10,000 ft. (3048 m)

Storage: Up to 40,000 ft. (12192 m)

Maximum frame size

Ethernet standards

9216 bytes

802.3i (10BaseT), Cable: (Cat 5 UTP)

802.3u (100BaseTX), Cable: (Cat 5e/6 UTP, EIA/TIA 568)

802.3ab (1000Base-T), Cable: (Cat -5e/6, UTP, EIA/TIA 568)

802.3z (1000Base-X), Cable: (SMF, MMF)

802.3ah (EFM), Cable: (SMF, MMF)

Maximum cable distance (RJ-45) 100 meters

1. Two SFP+ ports are provided with a plug-in module that replaces the CX4 plug-in module.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-7

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-24X

A B C

O mniSwitch 6850E-C24X

OK PRI PWR BP S

USB

CLAS S 1 LAS ER

PRODUCT

C onsole

R ear

R ear

F G H

D E

CLAS S 1 LAS ER

PRODUCT

OS6850E-24X Front Panel

Item Description

A

B

C

D

E

F

G

LED Indicator

Seven segment LED provides stack element ID.

USB Port

High speed USB port.

System Status LEDs

Provides status on hardware, software, primary and redundant power.

10/100/1000BaseT RJ-45 Ports and LEDs

10/100/1000BaseT non-combo and 10/100/1000BaseT combo ports. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

SFP Combo Ports and LEDs

Combo SFP connectors for various supported SFP transceivers. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

Console Port

RS-232 console port with an RJ-45 connector. Provides access to the CLI for configuration and management.

Rear Module Port LEDs

Provides link and traffic status for rear modules.

H SFP+ Ports and LEDs

Two non-combo SFP+ connectors for various supported SFP+ transceivers.

Refer to “OmniSwitch 6850E LED Status Indicators” on page 2-31 for LED status information.

Refer to “OmniSwitch 6850E Port Numbering” on page 2-30 for port numbering.

page 2-8 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-24X Rear Panel

B

C

D

Item

A

B

C

OS6850E-24X Rear Panel

D

Description

Grounding Block

Type LCD8-10A-L grounding lug

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Primary Power Supply Connector

DB-25 connector for required external primary power supply.

Stacking/SFP+ Uplink Module

Connectors for use in stacking switches into a virtual chassis or as uplink ports.

A

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-9

OmniSwitch 6850E Series Chassis and Hardware Components

OS6850E-24X Specifications

Total non-combo 10/100/

1000Base-T ports

Total 10/100/1000Base-T or SFP combo ports

Maximum SFP+ ports

1

Maximum CX4 stacking ports

Per switch - 20

Per stack - 160

Per switch - 4

Per stack - 32

Per switch - 4

Per stack - 32 (Note: 16 used for stacking)

Per switch - 2

Per stack - 16

Power

Flash memory size

RAM memory size

Width

Height

Height (rack units)

Depth

Weight

See

“OmniSwitch 6850E Series Power Supplies” on page 3-2

128 MB

512 MB SDRAM

17.32 in. (44.0 cm)

1.73 in. (4.4 cm)

1 RU

10.59 in. (26.9 cm)

8.40 lbs. (3.81 kg)

Relative Humidity

Ambient Temperature

Altitude

Operating: 5% to 95% (non-condensing)

Storage: 5% to 95% (non-condensing)

Operating: 32º F to 113º F (0 ºC to 45 ºC)

Storage: 14º F to 158º F (-10 ºC to 70 ºC)

Operating: Up to 10,000 ft. (3048 m)

Storage: Up to 40,000 ft. (12192 m)

9216 bytes Maximum frame size

Ethernet standards 802.3i (10BaseT), Cable: (Cat 5 UTP)

802.3u (100BaseTX), Cable: (Cat 5e/6 UTP, EIA/TIA 568)

802.3ab (1000Base-T), Cable: (Cat -5e/6, UTP, EIA/TIA 568)

802.3z (1000Base-X), Cable: (SMF, MMF)

802.3ah (EFM), Cable: (SMF, MMF)

Maximum cable distance (RJ-45) 100 meters

1. Two SFP+ ports are provided with a plug-in module that replaces the CX4 plug-in module.

page 2-10 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-P24X

A B C

O mniSwitch 6850E-P24X

OK PRI PWR BP S

USB

CLAS S 1 LAS ER

PRODUCT

C onsole

R ear

R ear

F G H

D E

CLAS S 1 LAS ER

PRODUCT

OS6850E-P24X Front Panel

Item Description

A

B

C

D

E

F

G

H

LED Indicator

Seven segment LED provides stack element ID.

USB Port

High speed USB port.

System Status LEDs

Provides status on hardware, software, primary and redundant power.

10/100/1000BaseT RJ-45 PoE Ports and LEDs

10/100/1000BaseT non-combo and 10/100/1000BaseT combo ports. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

SFP Combo Ports and LEDs

Combo SFP connectors for various supported SFP transceivers. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

Console Port

RS-232 console port with an RJ-45 connector. Provides access to the CLI for configuration and management.

Rear Module Port LEDs

Provides link and traffic status for rear modules.

SFP+ Ports and LEDs

Two non-combo SFP+ connectors for various supported SFP+ transceivers.

Refer to “OmniSwitch 6850E LED Status Indicators” on page 2-31 for LED status information.

Refer to “OmniSwitch 6850E Port Numbering” on page 2-30 for port numbering.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-11

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-P24X Rear Panel

A B

C

D

E

Item

A

B

C D

OS6850E-P24X Rear Panel

E

Description

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Grounding Block

Type LCD8-10A-L grounding lug

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Primary Power Supply Connector

DB-25 connector for required external primary power supply.

Stacking/SFP+ Uplink Module

Connectors for use in stacking switches into a virtual chassis or as uplink ports.

Note . The rear panel of the PoE models contain three DB-25 power supply connectors. One of the connectors is the for the primary power supply and two of the connectors are for the redundant power supplies. The primary power supply must be connected to the primary connector. A redundant power supply can be connected to either of the redundant connectors. page 2-12 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OS6850E-P24X Specifications

Total non-combo 10/100/

1000Base-T PoE ports

Total 10/100/1000Base-T PoE or

SFP combo ports

Total PoE ports (non-combo and combo)

Maximum SFP+ ports

1

Per switch - 20

Per stack - 160

Per switch - 4

Per stack - 32

Per switch - 24

Per stack - 192

Per switch - 4

Per stack - 32 (Note: 16 used for stacking)

Maximum CX4 stacking ports

Power

Flash memory size

RAM memory size

Width

Height

Height (rack units)

Depth

Weight

Relative Humidity

Per switch - 2

Per stack - 16

See

“OmniSwitch 6850E Series Power Supplies” on page 3-2

128 MB

512 MB SDRAM

17.32 in. (44.0 cm)

1.73 in. (4.4 cm)

1 RU

10.59 in. (26.9 cm)

Ambient Temperature

Altitude

8.62 lbs. (3.91 kg)

Operating: 5% to 95% (non-condensing)

Storage: 5% to 95% (non-condensing)

Operating: 32º F to 113º F (0 ºC to 45 ºC)

Storage: 14º F to 158º F (-10 ºC to 70 ºC)

Operating: Up to 10,000 ft. (3048 m)

Storage: Up to 40,000 ft. (12192 m)

Maximum frame size

Ethernet standards

9216 bytes

802.3i (10BaseT), Cable: (Cat 5 UTP)

802.3u (100BaseTX), Cable: (Cat 5e/6 UTP, EIA/TIA 568)

802.3ab (1000Base-T), Cable: (Cat -5e/6, UTP, EIA/TIA 568)

802.3z (1000Base-X), Cable: (SMF, MMF)

802.3ah (EFM), Cable: (SMF, MMF)

Maximum cable distance (RJ-45) 100 meters

1. Two SFP+ ports are provided with a plug-in module that replaces the CX4 plug-in module.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-13

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-48

A B C

O mniSwitch 6850E-C48

OK PRI PWR BP S

USB

D

C onsole

R ear

R ear

E F

CLAS S 1 LAS ER PRODUCT

G

OS6850E-48 Front Panel

Item Description

A

B

C

D

E

F

G

LED Indicator

Seven segment LED provides stack element ID.

USB Port

High speed USB port.

System Status LEDs

Provides status on hardware, software, primary and redundant power.

10/100/1000BaseT RJ-45 Ports and LEDs

10/100/1000BaseT non-combo and 10/100/1000BaseT combo ports. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

Console Port

RS-232 console port with an RJ-45 connector. Provides access to the CLI for configuration and management.

Rear Module Port LEDs

Provides link and traffic status for rear modules.

SFP Combo Ports and LEDs

Combo SFP connectors for various supported SFP transceivers.

Refer to “OmniSwitch 6850E LED Status Indicators” on page 2-31 for LED status information.

Refer to “OmniSwitch 6850E Port Numbering” on page 2-30 for port numbering.

page 2-14 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-48 Rear Panel

Note. The figure shows a pre-production version of the chassis without product, safety, and compliance information labels. All production versions of the chassis have these labels.

A

B

C

D

Item

A

B C

OS6850E-48 Rear Panel

D

Description

Grounding Block

Type LCD8-10A-L grounding lug

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Primary Power Supply Connector

DB-25 connector for required external primary power supply.

Stacking/SFP+ Uplink Module

Connectors for use in stacking switches into a virtual chassis or as uplink ports.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-15

OmniSwitch 6850E Series Chassis and Hardware Components

OS6850E-48 Specifications

Total non-combo 10/100/

1000Base-T PoE ports

Total 10/100/1000Base-T or SFP combo ports per switch

Maximum SFP+ ports

1

Maximum CX4 stacking ports

Per switch - 44

Per stack - 352

Per switch - 4

Per stack - 32

Per switch - 2

Per stack - 16 (Note: All used for stacking)

Per switch - 2

Per stack - 16

Power

Flash memory size

RAM memory size

Width

Height

Height (rack units)

Depth

Weight

See

“OmniSwitch 6850E Series Power Supplies” on page 3-2

128 MB

512 MB SDRAM

17.32 in. (44.0 cm)

1.73 in. (4.4 cm)

1 RU

10.59 in. (26.9 cm)

8.71 lbs. (3.95 kg)

Relative Humidity

Ambient Temperature

Altitude

Operating: 5% to 95% (non-condensing)

Storage: 5% to 95% (non-condensing)

Operating: 32º F to 113º F (0 ºC to 45 ºC)

Storage: 14º F to 158º F (-10 ºC to 70 ºC)

Operating: Up to 10,000 ft. (3048 m)

Storage: Up to 40,000 ft. (12192 m)

9216 bytes Maximum frame size

Ethernet standards 802.3i (10BaseT), Cable: (Cat 5 UTP)

802.3u (100BaseTX), Cable: (Cat 5e/6 UTP, EIA/TIA 568)

802.3ab (1000Base-T), Cable: (Cat -5e/6, UTP, EIA/TIA 568)

802.3z (1000Base-X), Cable: (SMF, MMF)

802.3ah (EFM), Cable: (SMF, MMF)

Maximum cable distance (RJ-45) 100 meters

1. Two SFP+ ports are provided with a plug-in module that replaces the CX4 plug-in module.

page 2-16 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-P48

A B C

O mniSwitch 6850E-P48

OK PRI PWR BP S

USB

D

C onsole

R ear

R ear

E F

CLAS S 1 LAS ER PRODUCT

G

OS6850E-P48 Front Panel

Item Description

A

B

C

D

E

F

G

LED Indicator

Seven segment LED provides stack element ID.

USB Port

High speed USB port.

System Status LEDs

Provides status on hardware, software, primary and redundant power.

10/100/1000BaseT RJ-45 PoE Ports and LEDs

10/100/1000BaseT non-combo and 10/100/1000BaseT combo ports. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

Console Port

RS-232 console port with an RJ-45 connector. Provides access to the CLI for configuration and management.

Rear Module Port LEDs

Provides link and traffic status for rear modules.

SFP Combo Ports and LEDs

Combo SFP connectors for various supported SFP transceivers.

Refer to “OmniSwitch 6850E LED Status Indicators” on page 2-31 for LED status information.

Refer to “OmniSwitch 6850E Port Numbering” on page 2-30 for port numbering.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-17

OmniSwitch 6850E-P48 Rear Panel

OmniSwitch 6850E Series Chassis and Hardware Components

A B

D

E

B

C

Item

A

C D

OS6850E-P48 Rear Panel

E

Description

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Grounding Block

Type LCD8-10A-L grounding lug

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Primary Power Supply Connector

DB-25 connector for required external primary power supply.

Stacking/SFP+ Uplink Module

Connectors for use in stacking switches into a virtual chassis or as uplink ports

Note . The rear panel of the PoE models contain three DB-25 power supply connectors. One of the connectors is the for the primary power supply and two of the connectors are for the redundant power supplies. The primary power supply must be connected to the primary connector. A redundant power supply can be connected to either of the redundant connectors. page 2-18 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OS6850E-P48 Specifications

Total non-combo 10/100/

1000Base-T PoE ports

Total 10/100/1000Base-T PoE or

SFP combo ports per switch

Total PoE ports (non-combo and combo)

Maximum SFP+ ports

1

Per switch - 44

Per stack - 352

Per switch - 4

Per stack - 32

Per switch - 48

Per stack - 384

Per switch - 2

Per stack - 16 (Note: All used for stacking)

Maximum CX4 stacking ports

Power

Flash memory size

RAM memory size

Width

Height

Height (rack units)

Depth

Weight

Relative Humidity

Per switch - 2

Per stack - 16

See

“OmniSwitch 6850E Series Power Supplies” on page 3-2

128 MB

512 MB SDRAM

17.32 in. (44.0 cm)

1.73 in. (4.4 cm)

1 RU

10.59 in. (26.9 cm)

Ambient Temperature

Altitude

9.23 lbs. (4.20 kg)

Operating: 5% to 95% (non-condensing)

Storage: 5% to 95% (non-condensing)

Operating: 32º F to 113º F (0 ºC to 45 ºC)

Storage: 14º F to 158º F (-10 ºC to 70 ºC)

Operating: Up to 10,000 ft. (3048 m)

Storage: Up to 40,000 ft. (12192 m)

Maximum frame size

Ethernet standards

9216 bytes

802.3i (10BaseT), Cable: (Cat 5 UTP)

802.3u (100BaseTX), Cable: (Cat 5e/6 UTP, EIA/TIA 568)

802.3ab (1000Base-T), Cable: (Cat -5e/6, UTP, EIA/TIA 568)

802.3z (1000Base-X), Cable: (SMF, MMF)

802.3ah (EFM), Cable: (SMF, MMF)

Maximum cable distance (RJ-45) 100 meters

1. Two SFP+ ports are provided with a plug-in module that replaces the CX4 plug-in module.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-19

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-48X

A B C

O mniSwitch 6850E-48X

OK PRI PWR BP S

USB

1 2

CLAS S 1 LAS ER

PRODUCT

C onsole

R ear

R ear

E F G H

D

OS6850E-48X Front Panel

Item Description

A

B

C

D

E

F

LED Indicator

Seven segment LED provides stack element ID.

USB Port

High speed USB port.

System Status LEDs

Provides status on hardware, software, primary and redundant power.

10/100/1000BaseT RJ-45 Ports and LEDs

10/100/1000BaseT non-combo and 10/100/1000BaseT combo ports. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

Console Port

RS-232 console port with an RJ-45 connector. Provides access to the CLI for configuration and management.

Rear Module Port LEDs

Provides link and traffic status for rear modules.

G

H

SFP+ Ports and LEDs

Two non-combo SFP+ connectors for various supported SFP+ transceivers.

SFP Combo Ports and LEDs

Combo SFP connectors for various supported SFP transceivers.

Refer to “OmniSwitch 6850E LED Status Indicators” on page 2-31 for LED status information.

Refer to “OmniSwitch 6850E Port Numbering” on page 2-30 for port numbering.

page 2-20 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-48X Rear Panel

B

C

D

Item

A

B C

OS6850E-48X Rear Panel

D

Description

Grounding Block

Type LCD8-10A-L grounding lug

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Primary Power Supply Connector

DB-25 connector for required external primary power supply.

Stacking/SFP+ Uplink Module

Connectors for use in stacking switches into a virtual chassis or as uplink ports

A

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-21

OmniSwitch 6850E Series Chassis and Hardware Components

OS6850E-48X Specifications

Total non-combo 10/100/

1000Base-T PoE ports

Total 10/100/1000Base-T or SFP combo ports per switch

Maximum SFP+ ports

1

Maximum CX4 stacking ports

Per switch - 46

Per stack - 368

Per switch - 2

Per stack - 16

Per switch - 4

Per stack - 32 (Note: 16 used for stacking)

Per switch - 2

Per stack - 16

Power

Flash memory size

RAM memory size

Width

Height

Height (rack units)

Depth

Weight

See

“OmniSwitch 6850E Series Power Supplies” on page 3-2

128 MB

512 MB SDRAM

17.32 in. (44.0 cm)

1.73 in. (4.4 cm)

1 RU

10.59 in. (26.9 cm)

8.75 lbs. (3.97 kg)

Relative Humidity

Ambient Temperature

Altitude

Operating: 5% to 95% (non-condensing)

Storage: 5% to 95% (non-condensing)

Operating: 32º F to 113º F (0 ºC to 45 ºC)

Storage: 14º F to 158º F (-10 ºC to 70 ºC)

Operating: Up to 10,000 ft. (3048 m)

Storage: Up to 40,000 ft. (12192 m)

9216 bytes Maximum frame size

Ethernet standards 802.3i (10BaseT), Cable: (Cat 5 UTP)

802.3u (100BaseTX), Cable: (Cat 5e/6 UTP, EIA/TIA 568)

802.3ab (1000Base-T), Cable: (Cat -5e/6, UTP, EIA/TIA 568)

802.3z (1000Base-X), Cable: (SMF, MMF)

802.3ah (EFM), Cable: (SMF, MMF)

Maximum cable distance (RJ-45) 100 meters

1. Two SFP+ ports are provided with a plug-in module that replaces the CX4 plug-in module.

page 2-22 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-P48X

A B C

O mniSwitch 6850E-P48X

OK PRI PWR BP S

USB

1 2

CLAS S 1 LAS ER

PRODUCT

C onsole

R ear

R ear

E F G H

D

OS6850E-P48X Front Panel

Item Description

A

B

C

D

E

F

G

H

LED Indicator

Seven segment LED provides stack element ID.

USB Port

High speed USB port.

System Status LEDs

Provides status on hardware, software, primary and redundant power.

10/100/1000BaseT RJ-45 PoE Ports and LEDs

10/100/1000BaseT non-combo and 10/100/1000BaseT combo ports. Odd-numbered ports are on top row, even-numbered ports are on bottom row.

Console Port

RS-232 console port with an RJ-45 connector. Provides access to the CLI for configuration and management.

Rear Module Port LEDs

Provides link and traffic status for rear modules.

SFP+ Ports and LEDs

Two non-combo SFP+ connectors for various supported SFP+ transceivers.

SFP Combo Ports and LEDs

Combo SFP connectors for various supported SFP transceivers.

Refer to “OmniSwitch 6850E LED Status Indicators” on page 2-31 for LED status information.

Refer to “OmniSwitch 6850E Port Numbering” on page 2-30 for port numbering.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-23

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-P48X Rear Panel

A B

B

C

D

E

Item

A

C D

OS6850E-P48X Rear Panel

E

Description

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Grounding Block

Type LCD8-10A-L grounding lug

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Primary Power Supply Connector

DB-25 connector for required external primary power supply.

Stacking/SFP+ Uplink Module

Connectors for use in stacking switches into a virtual chassis or as uplink ports

Note . The rear panel of the PoE models contain three DB-25 power supply connectors. One of the connectors is the for the primary power supply and two of the connectors are for the redundant power supplies. The primary power supply must be connected to the primary connector. A redundant power supply can be connected to either of the redundant connectors. page 2-24 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OS6850E-P48X Specifications

Total non-combo 10/100/

1000Base-T PoE ports

Total 10/100/1000Base-T PoE or

SFP combo ports per switch

Total PoE ports (non-combo and combo)

Maximum SFP+ ports

1

Per switch - 46

Per stack - 368

Per switch - 2

Per stack - 16

Per switch - 48

Per stack - 384

Per switch - 4

Per stack - 32 (Note: 16 used for stacking)

Maximum CX4 stacking ports

Power

Flash memory size

RAM memory size

Width

Height

Height (rack units)

Depth

Weight

Relative Humidity

Per switch - 2

Per stack - 16

See

“OmniSwitch 6850E Series Power Supplies” on page 3-2

128 MB

512 MB SDRAM

17.32 in. (44.0 cm)

1.73 in. (4.4 cm)

1 RU

10.59 in. (26.9 cm)

Ambient Temperature

Altitude

9.28 lbs. (4.21 kg)

Operating: 5% to 95% (non-condensing)

Storage: 5% to 95% (non-condensing)

Operating: 32º F to 113º F (0 ºC to 45 ºC)

Storage: 14º F to 158º F (-10 ºC to 70 ºC)

Operating: Up to 10,000 ft. (3048 m)

Storage: Up to 40,000 ft. (12192 m)

Maximum frame size

Ethernet standards

9216 bytes

802.3i (10BaseT), Cable: (Cat 5 UTP)

802.3u (100BaseTX), Cable: (Cat 5e/6 UTP, EIA/TIA 568)

802.3ab (1000Base-T), Cable: (Cat -5e/6, UTP, EIA/TIA 568)

802.3z (1000Base-X), Cable: (SMF, MMF)

802.3ah (EFM), Cable: (SMF, MMF)

Maximum cable distance (RJ-45) 100 meters

1. Two SFP+ ports are provided with a plug-in module that replaces the CX4 plug-in module.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-25

OmniSwitch 6850E-U24X

A B C D

OmniSwitch 6850E Series Chassis and Hardware Components

E F G

H

OS6850E-U24X Front Panel

Item Description

A

B

C

D

E

F

G

H

LED Indicator

Seven segment LED provides stack element ID.

USB Port

High speed USB port.

System Status LEDs

Provides status on hardware, software, primary and redundant power.

SFP Ports and LEDs

Combo and non-combo SFP connectors for various supported SFP transceivers.

Console Port

RS-232 console port with an RJ-45 connector. Provides access to the CLI for configuration and management.

Rear Module Port LEDs

Provides link and traffic status for rear modules.

SFP+ Ports and LEDs

Two non-combo SFP+ connectors for various supported SFP+ transceivers.

10/100/1000BaseT RJ-45 Combo Ports and LEDs

10/100/1000BaseT RJ-45 combo ports.

Refer to “OmniSwitch 6850E LED Status Indicators” on page 2-31 for LED status information.

Refer to “OmniSwitch 6850E Port Numbering” on page 2-30 for port numbering.

page 2-26 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OmniSwitch 6850E-U24X Rear Panel

C

D

Item

A

B

B C

OS6850E-U24X Rear Panel

D

Description

Grounding Block

Type LCD8-10A-L grounding lug

Redundant Power Supply Connector

DB-25 connector for optional external redundant power supply.

Primary Power Supply Connector

DB-25 connector for required external primary power supply.

Stacking/SFP+ Uplink Module

Connectors for use in stacking switches into a virtual chassis or as uplink ports.

A

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-27

OmniSwitch 6850E Series Chassis and Hardware Components

OS6850E-U24X Specifications

Total non-combo SFP ports

Total 10/100/1000Base-T or SFP combo ports per switch

Maximum SFP+ ports

1

Maximum CX4 stacking ports

Per switch - 22

Per stack - 176

Per switch - 2

Per stack - 16

Per switch - 4

Per stack - 32 (Note: 16 used for stacking)

Per switch - 2

Per stack - 16

Power

Flash memory size

RAM memory size

Width

Height

Height (rack units)

Depth

Weight

See

“OmniSwitch 6850E Series Power Supplies” on page 3-2

128 MB

512 MB SDRAM

17.32 in. (44.0 cm)

1.73 in. (4.4 cm)

1 RU

10.59 in. (26.9 cm)

8.31 lbs. (3.77 kg)

Relative Humidity

Ambient Temperature

Altitude

Operating: 5% to 95% (non-condensing)

Storage: 5% to 95% (non-condensing)

Operating: 32º F to 113º F (0 ºC to 45 ºC)

Storage: 14º F to 158º F (-10 ºC to 70 ºC)

Operating: Up to 10,000 ft. (3048 m)

Storage: Up to 40,000 ft. (12192 m)

9216 bytes Maximum frame size

Ethernet standards 802.3i (10BaseT), Cable: (Cat 5 UTP)

802.3u (100BaseTX), Cable: (Cat 5e/6 UTP, EIA/TIA 568)

802.3ab (1000Base-T), Cable: (Cat -5e/6, UTP, EIA/TIA 568)

802.3z (1000Base-X), Cable: (SMF, MMF)

802.3ah (EFM), Cable: (SMF, MMF)

Maximum cable distance (RJ-45) 100 meters

1. Two SFP+ ports are provided with a plug-in module that replaces the CX4 plug-in module.

page 2-28 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

OS6-XNI-U2 Module

A

Stack B/X2 Stack A/X1

OS6-XNI-U2 Module

Item Description

A SFP+ Ports and LEDs

Two SFP+ connectors for various supported SFP+ transceivers.

Refer to “OmniSwitch 6850E LED Status Indicators” on page 2-31 for LED status information.

Refer to “OmniSwitch 6850E Port Numbering” on page 2-30 for port numbering.

To check the status of the uplink/stacking module use the show ni command.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-29

OmniSwitch 6850E Port Numbering

The table below lists the port numbering for the OmniSwitch 6850E Series switches.

OS6850E-24

OS6850E-P24

OS6850E-24X

OS6850E-P24X

Non-Combo

Ports

1-20

1-20

1-20

1-20

Combo Ports

21-24

21-24

21-24

21-24

Non-Combo

SFP+ Ports

-

-

25-26

25-26

Stacking/Uplink

Ports

25-26

25-26

27-28

27-28

OS6850E-48

OS6850E-P48

OS6850E-48X

OS6850E-P48X

OS6850E-U24X

OmniSwitch 6850E Series Chassis and Hardware Components

5-48

5-48

3-48

3-48

1-22

1-4

1-4

1-2

1-2

23-24

OS6850E Port Numbering Table

-

-

49-50

49-50

25-26

49-50

49-50

51-52

51-52

27-28 page 2-30 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components OmniSwitch 6850E LED Status Indicators

OmniSwitch 6850E LED Status Indicators

LED

OK

PRI

PWR

BPS

State

Solid Green

Solid Amber

Blinking Green

Blinking Amber

Solid Green

Solid Amber

Off

Solid Green

Solid Amber

Off

Solid Green

Description

System software is operational.

Hardware or System failure.

Normal Diagnostics.

Switch operational but autoconfiguration not successful.

Primary unit in a stack or standalone switch.

Secondary unit in a stack.

Switch is idle. (not primary or secondary)

Primary power supply operational.

Primary power supply failure.

Primary power supply not present.

Redundant power supply operational.

Redundant power supply failure.

10/100/1000

Solid Amber

Off

Solid Green

Redundant power supply not present.

Valid Link.

Blinking Green

Solid Amber

Transmitting or receiving packets in a link up state for non-PoE .

Valid PoE Link.

SFP/SFP+

Rear

Blinking Amber

Off

Solid Green

Blinking Green

Off

Solid Green

Blinking Green

Off

Transmitting or receiving packets in a link up state for PoE .

No link.

Valid Link.

Transmitting or receiving packets .

No link.

Valid Link.

Transmitting or receiving packets .

No link.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-31

Mounting the Switch

Mounting the Switch

OmniSwitch 6850E Series Chassis and Hardware Components

Note . If you are relocating the switch, be sure to power it down and remove all network, stacking, and power cables before moving.

Airflow Considerations

Be sure that your switch is placed in a well-ventilated, static-free environment. Always allow adequate clearance at the front, rear, and sides of the switch.

The following diagram shows recommended minimum clearances for adequate chassis airflow and access to components at the rear of the chassis—e.g., backup power supply connectors and power cord(s).

}

Rear Recommended 5 inches minimum at rear of chassis for access to backup power supply connectors and power cord(s).

Sides 2 inches minimum at left and right sides for adequate airflow. For detailed information on chassis airflow, refer to

page 2-33

.

OK

PRI

PWR

BPS

1 2 3

4 5 6 7 8

USB

OmniSwitch 6850-48

ODUCT

CLASS 1 LASER PR

9 10 11

12 13

14 15 16

17 18 19

20 21 22

23 24

25 26

27 28 29

30 31

32 33 34

35 36

37 38 39 40 41

42 43 44

45 46 47

48

}

Front Recommended 6 inches minimum at front of chassis for access to LEDs and network cables.

OmniSwitch 6850E Series Chassis Top View

Note . Never obstruct the air vents located at the sides of the chassis. Obstructing these vents can cause switch failure. Clearance is not required at the top and bottom of the chassis. For detailed chassis airflow diagrams, refer to

“Chassis Airflow” on page 2-33 .

page 2-32 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components Mounting the Switch

Chassis Airflow

The fans pull air from the air intake vent located on the left-hand side of the chassis. The air is directed horizontally through the chassis and past the circuit board. Airflow is then exhausted through the fan vents at the right-hand side of the chassis. Refer to the illustrations below for more information.

1. Air Intake. The six chassis fans pull air from the main air intake vent located at the lefthand side of the chassis.

Console

45

47

46

48

Air Intake Vent

Left Side Air Intake Vent

Front of Chassis

2. Airflow. The air from the intake vent is directed through the chassis past the circuit board. This airflow provides required cooling for chassis components.

Front of Chassis

3. Air Exhaust. The airflow is exhausted through the six fan exhaust vents at the righthand side of the chassis.

Fan Exhaust Vents

Right Side Fan Exhaust Vents

Important . Maintain a clearance of at least two inches on the left and right sides. Otherwise, airflow may become restricted. Restricted airflow can cause your switch to overheat; overheating can lead to switch failure. See

“Airflow Considerations” on page 2-32

for more information on chassis clearances.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-33

Mounting the Switch OmniSwitch 6850E Series Chassis and Hardware Components

Blank Cover Panels

Blank cover panels are provided with your switch and are used to cover empty backup power supply bays and 10 Gigabit uplink bays. These cover panels play an important role in chassis airflow and temperature management. They also protect the switch’s processor board and other sensitive internal switch components from physical damage by closing off the chassis.

When blank cover panels are missing, air does not take the direct route from the air intake vent, through the chassis, and then out through the fan exhaust vents (see

page 2-33 ). Instead, a portion of the airflow is

allowed to be drawn in through the rear of the chassis. As a result, normal airflow is disrupted and an extra task is placed on the fans to cool the chassis.

If your switch is not equipped with a backup power supply connection or 10 Gigabit uplink, and blank cover panels are not installed over empty bay locations, airflow is adversely affected. Since they regulate airflow and help protect internal chassis components, blank cover panels should remain installed over empty bays at all times.

page 2-34 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components Mounting the Switch

Installation Options

The OmniSwitches can be installed in two ways:

Tabletop installation

Rack-mount installation

Installing the Switch on a Tabletop or Bench

OmniSwitches switches can be installed freestanding as tabletop units. Place your switch on a stable, flat, and static-free surface.

Note. Switches must be placed “right side up.” Never attempt to operate a switch positioned on its side.

Tabletop Mounting Steps

To install the switch as a tabletop unit, follow the steps below:

1 Position the chassis on the table or bench where it is to be installed.

2

Be sure that adequate clearance has been provided for chassis airflow and access to the front, back, and sides of the switch. For recommended clearances, refer to

page 2-32

. Also, be sure that you have placed the chassis within the reach of all the required AC power sources.

3 If you are installing a single (i.e., stand-alone) switch, continue to

tion” on page 2-38

for additional setup procedures.

“Setting Up a Stacked Configura-

If you are placing multiple switches in a stacked configuration, carefully stack the remaining switches, one on top of the other. Up to eight switches may be stacked to form a single virtual chassis. Be sure to maintain adequate clearance at the front, rear, left, and right side of all switches (see

page 2-32

). Also, be sure that you have placed all switches in the stack within reach of required AC power sources. Once the

switches are stacked together, continue to

“Cabling Stacked Configurations” on page 2-38 for additional

setup procedures.

Note. Switches should be added one at a time in a stack.

Note. For comprehensive information on operating switches in a stacked configuration, refer to Chapter 6,

“Managing OmniSwitch 6850E Series Stacks.”

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-35

Mounting the Switch OmniSwitch 6850E Series Chassis and Hardware Components

Rack-Mounting the Switch

Refer to the important guidelines below before installing the OmniSwitch chassis on a rack.

It is recommended that two people install the switch on the rack—one person to hold the chassis and position it on the rack, and a second person to secure the chassis to the rack using attachment screws

(not supplied).

Alcatel-Lucent provides two rack-mount flanges with each OmniSwitch switch. These flanges support standard 19-inch rack-mount installations. These flanges must be attached to the chassis before the switch can be rack mounted.

Note .

If you are installing the switch in a 23-inch-wide rack, Alcatel-Lucent offers optional 23-inch rackmounting hardware. For more information, contact your Alcatel-Lucent representative.

Alcatel-Lucent does not provide rack-mount screws. Use the screws supplied by the rack vendor.

To prevent a rack from becoming top heavy, it is recommended that you install heavier equipment at the bottom of the rack, whenever possible.

If you are installing the switch on a relay rack, be sure to install and secure the rack per the rack manufacturer’s specifications.

Review

page 2-32

for important chassis airflow and access recommendations before installing.

Rack Mounting Steps

To rack-mount the switch, follow the steps below:

1

Align the holes in the provided rack-mount flanges with the four threaded holes in the OmniSwitch chassis. These threaded holes are located in the left and right sides of the chassis, near the front panel.

2

Attach the flanges to the chassis using the provided Phillips-head screws. Be sure to tighten each of the screws firmly using a Phillips screwdriver.

45

46

Co nsole page 2-36

Attaching a Rack-Mount Flange

OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components Mounting the Switch

3

After the rack-mount flanges are secured to the chassis, mark the holes on the rack where the switch is to be installed.

4

Lift and position the switch until the rack-mount flanges are flush with the rack post.

5

Align the holes in the flanges with the rack holes that were marked in step 3.

6

Once the holes are aligned, insert a rack mount screw (not provided) through the bottom hole of each flange. Tighten both screws until they are secure.

Attaching the Switch to the Rack

Note . Be sure to install the screws in the bottom hole of each flange, as shown, before proceeding.

7 Once the screws at the bottom of each flange are secure, install the remaining two rack mount screws.

Be sure that all screws are securely tightened.

Note. If you are installing multiple switches in a rack to form a stacked configuration, refer to “Setting Up a Stacked Configuration” on page 2-38

.

Installing and Removing Combo Port SFPs

OmniSwitches offer four Gigabit Ethernet combo ports, located on the front panel (see

page 2-2 ). These

combo ports support hot-swappable fiber Small Form-Factor Pluggables (SFPs). For instructions on installing and removing combo connector SFPs, refer to the OmniSwitch Transceivers Guide.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-37

Setting Up a Stacked Configuration OmniSwitch 6850E Series Chassis and Hardware Components

Setting Up a Stacked Configuration

Rack Mounting Stacked Configurations

To rack mount a stacked configuration, install all switches that are to be included in the stacked configura-

tion as described on pages 2-36

through 2-37 . Up to eight switches may be stacked to form a single virtual

chassis.

Note. When rack mounting multiple switches in a stacked configuration, be sure to place all switches in vertically-adjacent rack positions. This will ensure that all required stacking cables will have adequate length for the installation.

Cabling Stacked Configurations

In order to connect stacked switches into a virtual chassis, all modules in the stack must be connected via stacking cables (provided).

Redundant Stacking Cable Connections

In addition to the stacking cables installed between adjacent switch, the top-most switch and bottom-most

switch in the stack must be connected using a redundant stacking cable. Refer to Chapter 6, “Managing

OmniSwitch 6850E Series Stacks”

for more information on the redundant stacking cable connection.

Supported Cabling Patterns

Each switch provides two stacking: stacking port A and stacking port B. Cables can be connected in any pattern. In other words, the cable connected to stacking port A of one switch can be connected to either stacking port A or stacking port B of the adjacent switch. However, it is strongly recommended that the cabling pattern remains consistent across the stack. For a cabling diagram and additional information on cabling the stack, refer to

Chapter 6, “Managing OmniSwitch 6850E Series Stacks.”

Cabling Steps

1 Before inserting a stacking cable into one of the stacking, be sure to orient the stacking cable connector properly. The wide portion of the connector must be facing up. Refer to the diagram below for more information.

Connector Top

When orienting the stacking cable connector, be sure that the wider portion of the connector is facing up as shown. Otherwise, the stacking cable will not fit properly in the chassis’ stacking port.

End View of Stacking Cable Connector

2 Starting from the top of the stack, insert one end of the stacking cable into either stacking port A or

stacking port B. The stacking port (A or B) depends on your preferred cabling pattern. Refer to Chapter 6,

“Managing OmniSwitch 6850E Series Stacks” for detailed information on cabling patterns. Be sure that

cable connector is completely inserted and fully seated in the chassis.

page 2-38 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components Setting Up a Stacked Configuration

3

Insert the other end of the stacking cable into the stacking port of the switch immediately below. Once again, the stacking port (A or B) depends on the preferred cabling pattern.

4

Repeat this procedure until all switches in the stack are connected (see illustrations a, b, and c below).

Reminder. The diagram below shows one supported stacking cable pattern. For additional supported cabling patterns, refer to

Chapter 6, “Managing OmniSwitch 6850E Series Stacks.”

a b

Connecting the Switches in the Stack c

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-39

Setting Up a Stacked Configuration OmniSwitch 6850E Series Chassis and Hardware Components

5

To provide added resiliency and redundancy, you must install the redundant stacking cable to connect the top switch in the stack to the bottom switch. Connect the redundant cable now. Refer to the diagram below for more information:

Redundant Connection Between Top and Bottom Switches

6

Once all stacking cable connectors are inserted, tighten the captive screws at the left- and right-hand sides of each connector as shown. Be sure not to overtighten the screws.

Tightening Stacking Connector Captive Screws

7

Now that all switches in the stack are connected, continue to

“Booting OmniSwitch 6850E Series

Switches” on page 2-41 .

page 2-40 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components Booting OmniSwitch 6850E Series Switches

Booting OmniSwitch 6850E Series Switches

For information on booting stand-alone switches and switches in stacked configurations, refer to the sections below.

Booting a Stand-Alone Switch

The OmniSwitch switch does not use an on/off switch. The power cord is the switch’s only connect/ disconnect device. The power connector socket is located on the switch’s rear panel. For more information, refer to “Rear Panel” on page 2-55 .

To boot the switch, plug the power cord (provided) into the power connector socket at the switch’s rear panel. Next, plug the power cord into an easily-accessible power source, such as a grounded AC outlet or an Uninterruptible Power Supply (UPS).

The switch immediately begins the boot process. Allow a few moments for the switch to boot completely, then verify the status of all LEDs on the switch’s front panel. A successful boot for a stand-alone switch displays the following LED states:

LED States for a Stand-Alone Switch

OK

PRI

PWR

BPS

Slot Indicator

Solid green

Blinking amber - Switch is operational but Auto-Configuration was not successful.

Solid green

Solid green

Solid amber if BPS attached is failed and off when no operational backup power supply (BPS) is attached; solid green if an operational

BPS is attached and operating normally.

1–8 (non-blinking), depending on the slot number value in the boot.slot.cfg file. The default value is 1.

If any of the LED state differs from the states shown in the table above, refer to page 2-53 for more information. Contact Alcatel-Lucent Customer Support if the LED state persists.

For information on logging in and configuring your OmniSwitch, refer to the Getting Started Guide and

Switch Management Guide.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-41

Booting OmniSwitch 6850E Series Switches OmniSwitch 6850E Series Chassis and Hardware Components

Booting Stacked Configurations

Once the switches have been connected to a virtual chassis, the next step is to manually power on the stack. The OmniSwitch switch does not use an on/off switch. The power cord is the switch’s only connect/ disconnect device. The power connector socket is located on the switch’s rear panel. For more information, refer to “Rear Panel” on page 2-55 .

To boot the stack, plug the power cord (provided) into the power connector socket at the rear panel of each switch in the stack. Next, plug all power cords, in rapid succession, into easily-accessible power sources, such as grounded AC outlets or an Uninterruptible Power Supply (UPS).

Note. Be sure to power on all switches in the stack in rapid succession; otherwise, switches may be

assigned unintended stack management roles. Refer to Chapter 6, “Managing OmniSwitch 6850E Series

Stacks”

for detailed information.

The stack immediately begins the boot process. Allow a few moments for all elements in the stack to boot completely, then verify the status of all LEDs on the switch’s front panel. A successful boot for a standalone switch displays the following LED states.

LED States for a Stacked Configuration

OK

PRI

PWR

BPS

Slot Indicator

Solid green for all switches.

Blinking amber - Switch is operational but Auto-Configuration was not successful.

Solid green for the primary management module; solid amber for the secondary management module; off for switches operating in idle roles.

Detailed information for primary, secondary, and idle roles is provided in

Chapter 6, “Managing OmniSwitch 6850E Series Stacks.”

Solid green for all switches.

Solid amber if BPS attached is failed and off when no operational backup power supply (BPS) is attached; solid green if an operational

BPS is attached and operating normally.

1–8 (non-blinking), depending on the slot number assignment for each

corresponding switch. See Chapter 6, “Managing OmniSwitch 6850E

Series Stacks”

for detailed information.

If any of the LED state differs from the states shown in the table above, refer to page 2-53 for more information. Contact Alcatel-Lucent Customer Support if the LED state persists. For information on logging in and configuring your OmniSwitch stack, refer to the Getting Started Guide and OmniSwitch Switch

Management Guide.

page 2-42 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components Power Cords

Power Cords

Since the power cord is the switch’s only disconnect device, it should be plugged into an easily accessible outlet. In the event that your power cord is lost or damaged, refer to the specifications below.

Specifications

The power cord to be used with 115 Volt configuration is a minimum type SJT (SVT) 18/3, rated at 250

Volts AC, 10 Amps with a maximum length of 15 feet. One end terminates in an IEC 320 attachment plug and the other end terminates in a NEMA 5-15P plug.

The power cord to be used with 230 Volt configuration is minimum type SJT (SVT) 18/3, rated 250 Volts

AC, 10 Amps with a maximum length of 15 feet. One end terminates in an IEC 320 attachment plug and the other end terminates as required by the country where it will be installed.

European cords must be Harmonized (HAR) type. Refer to the information below for power plug types by region:

Power Cord Types

North America

United Kingdom / Ireland

Europe

Japan

Australia

India

Italy

Switzerland / Liechtenstein

Denmark / Greenland

Argentina

NEMA 5-15-P (US), C22.2, No. 42 (Canada)

BS 1,363

CEE 7/7

JIS 8,303

AS 3,112

BS 546

CIE 2,316

SEV 1011

SRAF 1,962 / D816 / 87

AR1-10P

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-43

Console Port OmniSwitch 6850E Series Chassis and Hardware Components

Console Port

The console port, located on the chassis front panel, provides a console connection to the switch and is required when logging into the switch for the first time. By default, this RJ-45 connector provides a DTE console connection.

Serial Connection Default Settings

The factory default settings for the serial connection are as follows: baud rate parity data bits (word size) stop bits flow control

8

1

9600 none none

Modifying the Serial Connection Settings

The switch’s serial connection defaults are listed above. If you wish to modify the default serial connection settings (i.e., baud rate, parity, data bits, and stop bits), refer to the following steps:

Note .

You must be connected to the switch via the console port before attempting to change serial connection settings. Otherwise, an error message will display.

For switches in a stacked configuration, all changes must be configured before the switches are cabled together. In other words, you must configure these settings when each switch is operating as a stand-alone unit.

1

Enter the modify boot parameters command at the CLI prompt. The boot prompt displays:

Boot >

2 To change the baud rate, enter boot serialbaudrate, followed by the desired baud rate value. Options include 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 76800, and 115200. For example:

Boot > boot serialbaudrate 19200

Note . Setting the console port to speeds above 9600 baud can cause problems with Zmodem uploads.

3

To change the parity value, enter boot serialparity, followed by the desired parity value. Options include none (default), even, and odd. For example:

Boot > boot serialparity even

4

To change the data bits (i.e., word size) value, enter boot serialwordsize, followed by the number of data bits. Options include 7 and 8 (default). For example:

Boot > boot serialwordsize 7 page 2-44 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components Console Port

5

To change the stop bits value, enter boot serialstopbits, followed by the number of stop bits. Options include 1 (default) and 2. For example:

Boot > boot serialstopbits 2

6 Verify your current changes by entering show at the boot prompt:

Boot > show

Edit buffer contents:

Serial (console) baud : 19200

Serial (console) parity : even

Serial (console) stopbits : 2

Serial (console) wordsize : 7

(additional table output not shown)

7

You can save your changes to the boot.params file by entering commit file at the boot prompt:

Boot > commit file

When the commit file command is used, changes will not be enabled until after the next switch reboot.

8

You can also save your changes in real time to the switch’s running memory by entering commit system at the boot prompt:

Boot > commit system

Caution .

There are two important things to consider when using the commit system command to save serial connection changes:

Output to the terminal may become illegible due to incompatible serial connection settings between the switch and the terminal emulation software.

If you use the commit system command only, changes will not be saved to the switch’s boot.params file and will be lost if the switch is rebooted. To save changes to the boot.params file, refer to step 7.

9

Return to the CLI prompt by entering exit at the boot prompt.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-45

Console Port OmniSwitch 6850E Series Chassis and Hardware Components

Console Port Pinouts

10/100 Ethernet Port – RJ-45 Pinout (non-PoE)

Pin Number

7

8

5

6

3

4

1

2

Description

RX+

RX-

TX+ not used not used

TXnot used not used

Gigabit Ethernet Port – RJ-45 Pinout

Pin Number

7

8

5

6

3

4

1

2

Description

BI_DB+

BI_DB-

BI_DA+

BI_DD+

BI_DD-

BI_DA-

BI_DC+

BI_DC-

10/100/1000 Mbps Power over Ethernet Port – RJ-45 Pinout

Pin Number

7

8

5

6

3

4

1

2

Description

RX+ (-VDC)

RX- (-VDC)

TX+ (+VDC)

TX- (+VDC) page 2-46 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components

RJ-45 Console Port – Connector Pinout

Pin Number

7

8

5

6

3

4

1

2

Signals as DTE Console Port

NC

NC

RXD

Ground

Ground

TXD

NC

NC

Console Port

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-47

Dying Gasp OmniSwitch 6850E Series Chassis and Hardware Components

Dying Gasp

If the switch loses all power it will maintain power long enough to send a Dying Gasp message before completely shutting down. An SNMP trap, Syslog message and Link OAM PDUs will be generated.

Scenarios

A Dying Gasp event will be generated in the following scenarios:

Primary power supply failure (if only power supply present).

Primary power supply failure and then backup power supply failure.

Backup power supply failure and then primary power supply failure.

When a reload command is issued.

When a takeover command is issued.

Note. Dying gasp will not work when both primary and backup power supplies fail simultaneously.

Connect each power supply to a separate independent power source to avoid simultaneous power failures.

SNMP Trap

As soon as the power failure is detected, an SNMP trap is sent to the first three configured SNMP stations.

The trap includes the following information:

Slot number

Power supply type (primary/backup)

Time of the failure

Use the snmp station command and refer to the SNMP Configuration chapter for information on configuring an SNMP station.

Syslog Message

As soon as the power failure is detected, the following Syslog message is sent to the first four configured

Syslog servers, along with the time of the failure:

Dying Gasp Power Failure Event Occurred

Use the swlog output socket command to add a Syslog station. Refer to the Using Switch Logging

Configuration chapter in the Network Configuration Guide for information on configuring a Syslog server. page 2-48 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Chassis and Hardware Components Dying Gasp

Link OAM PDU

As soon as the power failure is detected an 802.3ah OAM Information PDU is sent to all ports for which link OAM is enabled and the LinkOAM port status is operational. The PDU will have the Dying Gasp bit set.

Use the

efm-oam

and

efm-oam port propagate-events

commands to enable the generation of an

802.3ah OAM Information PDU upon a dying gasp event:

-> efm-oam enable

-> efm-oam port 2/1-10 propagate-events dying-gasp enable

Link OAM PDU Priority

It may not be possible to generate PDUs on all ports enabled for link OAM. Dying gasp packets will be sent in the following order based on port priority:

1. Uplink ports

2. Combo ports

3. All other ports

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 2-49

Dying Gasp OmniSwitch 6850E Series Chassis and Hardware Components page 2-50 OmniSwitch 6850E Series Hardware Users Guide

January 2013

3 OmniSwitch 6850E Series

Power Supplies

OmniSwitch 6850E Series switches various Power over Ethernet (PoE) and non-PoE AC and DC Power supplies.

This chapter includes detailed information on these power supply types. Topics include:

Power suppy technical specifications

Power supply chassis support

Power supply installation and mounting

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 3-1

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

OmniSwitch 6850E Series Power Supplies

OmniSwitch 6850E Series switches support the following power supplies:

PS-900W-AC power supply (see

“PS-900AC-P Power Supply” on page 3-4 )

PS-510W-AC power supply (see

“PS-510W-AC-E Power Supply” on page 3-5

)

PS-510W-AC-E power supply (see

“PS-510W-AC-E Power Supply” on page 3-5 )

PS-360W-AC power supply (see

“PS-360W-AC-E Power Supply” on page 3-6

)

PS-360W-AC-E power supply (see

“PS-360W-AC-E Power Supply” on page 3-6 )

PS-126W-AC power supply (see

“PS-126W-AC Power Supply” on page 3-7

)

PS-120W-DC power supply (see

“PS-120W-DC Power Supply” on page 3-8

)

Approximately 120W is dedicated to system power needed for the chassis and the rest of the power is utilized for Power over Ethernet (PoE). The power supplies connect to the rear of the unit. There is a power shelf provided with the unit that slides into the rear of the chassis and is used to hold the power supplies. See the table below for valid configurations.

Model

All PoE Models

All PoE Models

All 48-Port PoE Models

All PoE Models

Primary Power

Supply

Backup Power Supply

Valid

Configuration?

510W

360W

510W

360W

Valid

Valid

900W 900W Valid

Non-PoE Power Supply Non-PoE Power Supply Not Valid

All Non-PoE Models

All Non-PoE Models

126W AC or 120W DC 126W AC or 120W DC Valid

PoE Power Supply PoE Power Supply Not Valid

The power supplies can also be connected using a cable, in case there is a need for a less deep chassis. In this case, the same power shelf can be mounted in the rack using the mounting ears (removable in case the power supply needs to be plugged into the rear of the chassis).

Note. PoE units do not support the mixing of unlike power supplies (i.e. 360W and 510W). If unlike power supplies are mixed or if an unsupported power supply (such as a 120W power supply) is used, a console message and a trap are generated.

Note. Non-PoE units support the mixing of unlike power supplies (i.e. 126W AC and 120W DC). page 3-2 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

Power Supply Shelf

Alcatel-Lucent requires the use of power supply shelf when the power supply is used in a 1U (i.e, 1.5 inches/3.8 cm) configuration. In a 2U (i.e., 3 inches/7.6 cm) configuration you can mount the power

supply tray directly to a rack. See “Installing Power Supplies” on page 3-9

for more information.

Power Supply Shelf

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 3-3

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

PS-900AC-P Power Supply

The PS-900AC-P Power Supply provides system and PoE power and can be installed as either a primary or redundant power supply.

900W AC System/PoE Power Supply

P/S Component

Model

Description

PS-900AC-P

Provides Primary and Redundant

System and PoE For

OmniSwitch 6850E 48-Port PoE Models

Input Voltage Range

Rated Frequency

90 to 265 VAC

47 to 63 Hz

Maximum PoE Output Power 780 W

Maximum System Output Power 126 W

PoE Output Voltage

PoE Output Current

Sytem Output Voltage

Sytem Output Current

-54.5 VDC

14.3 A

12.0 VDC

10.5 A page 3-4 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

PS-510W-AC-E Power Supply

The PS-510W-AC-E Power Supply provides enhanced system and PoE power and can be installed as either a primary or redundant power supply.

510W AC Enhanced System/PoE Power Supply

P/S Component

Model

Description

PS-510W-AC-E

Provides Primary and Redundant

System and PoE For

OmniSwitch 6850E PoE Models

Input Voltage Range

Rated Frequency

90 to 264 VAC

47 to 63 Hz

Maximum PoE Output Power 410 W

Maximum System Output Power 120 W

PoE Output Voltage

PoE Output Current

Sytem Output Voltage

Sytem Output Current

-54.5 VDC

7.53 A (maximum)

12.2 VDC (typical)

10.0 A (maximum)

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 3-5

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

PS-360W-AC-E Power Supply

The PS-360W-AC-E Power Supply provides enhanced system and PoE and can be installed as either a primary or redundant power supply.

360W Enhanced AC System/PoE Power Supply

P/S Component

Model

Description

PS-360W-AC-E

Provides Primary and Redundant

System and PoE For

OmniSwitch 6850E PoE Models

Input Voltage Range

Rated Frequency

90 to 264 VAC

47 to 63 Hz

Maximum PoE Output Power 230 W

Maximum System Output Power 130 W

PoE Output Voltage

PoE Output Current

-54.5 VDC

4.22 A (maximum)

Sytem Output Voltage

Sytem Output Current

12.0 VDC (typical)

10.8 A (maximum) page 3-6 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

PS-126W-AC Power Supply

The PS-126W-AC Power Supply provides system power and can be installed as a redundant system power supply.

126W AC System Power Supply

P/S Component Description

Model PS-126W-AC

Provides Primary and Redundant

System and PoE For

OmniSwitch 6850E non-PoE Models

Input Voltage Range

Rated Frequency

Maximum Output Power

Output Voltage

Output Current

90 to 264 VAC

50 to 60 Hz

126 W

12.0 VDC (typical)

10.5 A (maximum)

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 3-7

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

PS-120W-DC Power Supply

The PS-120W-DC Power Supply provides full system power and can be installed as a redundant system power supply.

120W -48VDC System Power Supply

P/S Component Description

Model PS-120W-DC

Provides Primary and Redundant

System and PoE For

OmniSwitch 6850E non-PoE Models

Input Voltage Range

Input Current

Maximum Output Power

Output Voltage

Output Current

36 to 72 VDC (24V Nominal Input)

3.3A @ 48VDC

120 W

12.0 VDC (typical)

10.0 A (maximum) page 3-8 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

Installing Power Supplies

Power supply can be installed in the following ways:

As a primary or backup supply directly connected to the back of a chassis. See “Connecting a Power

Supply Directly to the Chassis” on page 3-9

for more information.

As a primary or backup supply connected with a cable. See

“Connecting a Power Supply with a Cable” on page 3-10

for more information.

DC power supplies require additional installation steps. See “DC Power Supply Considerations” on page 3-14

for more information.

Anti-Static Warning. Before handling any components, free yourself of static by wearing a grounding strap, or by grounding yourself properly. Static discharge can damage the switch and the backup power supply.

Connecting a Power Supply Directly to the Chassis

Follow the steps below to connect a power supply directly (i.e., without a cable) to the back of the

OmniSwitch:

1

Place the chassis and power supply on a smooth, clean, and dry surface.

2 Optional. Follow steps a and b to install the power shelf.

a Carefully slide the power shelf so that it is flush against the back of the chassis.

b Tighten the two captive screws located on the left and right sides of the power shelf.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 3-9

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

3

Carefully slide the power supply against the back of the chassis until the power connector connects.

4

If you have installed the power shelf tighten the captive screws (or screws) located at back of the power supply to the power shelf.

Connecting a Power Supply with a Cable

The following sections describe how to rack-mount a power supply shelf and connect the power supply with a cable.

Power Supply Shelf Rack Mounting Steps

Follow the steps below to rack-mount the power supply shelf:

1

Align the threaded holes in the provided rack-mount flanges with the two holes in the power supply shelf. These holes are located on the left and right sides of the shelf.

2

Attach the flanges to the chassis using the provided Phillips-head screws. The screws slide through the non-threaded holes from the inside of the power supply shelf and are then attached to the mounting brackets using the threaded holes. Be sure to tighten each of the screws firmly using a Phillips screwdriver.

page 3-10

Attaching a Rack-Mount Flange

OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

3

Carefully slide the power supply on to the power shelf and secure the power supply to the shelf using the captive screws.

Tighten these screws to secure the power supply.

Attaching a Power Supply to the Power Shelf

Note. A single large (i.e. 510W) power supply or up to two smaller (i.e. 126W) power supplies can be attached to a power supply shelf.

4 After the rack-mount flanges and the power supply are secured to the shelf, mark the holes on the rack where the shelf is to be installed.

5

Lift and position the shelf until the rack-mount flanges are flush with the rack post.

6 Align the holes in the flanges with the rack holes that were marked earlier.

7

Once the holes are aligned, insert a rack mount screw (not provided) through the bottom hole of each flange. Tighten both screws until they are secure.

Attaching the Power Shelf to the Rack

Note .

Be sure to install the screws in the bottom hole of each flange, as shown, before proceeding.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 3-11

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

8

Once the screws at the bottom of each flange are secure, install the remaining two rack mount screws.

Be sure that all screws are securely tightened.

Connecting the Power Supply Cable

Follow the steps below to connect a power supply with a cable:

1 Be sure the switch and power shelf are securely fastened to the rack.

2

Connect the proper end of the supplied power supply cable to the appropriately labeled primary or backup connector on the switch and tighten securely.

3 Connect the other end of the power supply cable to the power supply and securely tighten.

4

Connect the power cord to the power supply.

Note. The diagrams below show examples of mounting the switch and power supplies in both a 2U and

3U scenario. Depending on the switch model, power supplies, and rack mounting options the actual mounting options will vary.

page 3-12 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Power Supplies

13.5 inches

OmniSwitch 6850E Series Power Supplies

Redundant Small Power Supplies (i.e 126W)

13.5 inches

Redundant Large Power Supplies (i.e. 510W)

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 3-13

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

You can also attach the power supplies to the back of a chassis directly as well as using cables at the same time, as shown in the diagram below.

17.6 inches

Redundant Large Power Supplies

DC Power Supply Considerations

In addition to the installation steps described in

“Connecting a Power Supply Directly to the Chassis” on page 3-9

and “Connecting a Power Supply with a Cable” on page 3-10

DC power supplies (e.g., the PS-

120W-DC) have the following additional considerations:

Connect to a -48V or -60V reliably grounded DC SELV source.

Use common DC return connections for the DC power supplies. The DC return terminal conductor should be connected to the equipment frame.

The Branch Circuit Overcurrent Protection must be rated a Maximum of 15A.

Use 12AWG solid conductors only.

A readily accessible disconnect device that is suitably approved and rated shall be incorporated in the field wiring.

Black

MIN 1 TURN PER 1.5

HALF TURN PER .75

Red

Twisted pair wire (red and black) for a DC power supply

Note. Refer to the wiring diagram for information on connecting the DC power supply to a DC power source.

page 3-14 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

Connecting a DC Power Source

The DC power supply on your switch contains a power connector with three (3) square slots for connecting the positive, negative, and ground wires from a DC power source.

DC Power Connectors

+ -

Side Screws for Connector Removal

OmniSwitch DC Power Supply Connector

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 3-15

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

A clamp inside each slot keeps the power wire tightly in place during operation.

The DC power supply has side screws that can be used to remove the connector if required.

Installing DC Power Source Wire Leads

These instructions describe how to connect your 3-wire DC power source to the power connector on your

DC power supply. A small flat-tip screwdriver and a wire stripper are required for this procedure.

1

Prepare the three (3) wires—12 gauge—that will plug into the power supply. First make sure they are not plugged into the DC power source. Next, use a wire stripper to carefully strip between .24 and .30 inches (6-7.5 mm) off the end of each wire, removing the outer insulation to expose the copper core.

2 Open the clamp for the ground wire slot by inserting a small flat-tip screwdriver into the top of the appropriate circular hole. Loosen the screw so that the clamp for the ground wire opens.

Loosen Screw.

+ -

Clamp inside square hole will open when screw is loosened in top circular hole.

Opening Connector for Ground Wire

3 Insert the ground wire lead into the slot. The lead you insert must match the lead attached to the DC power source.

Warning. You must plug DC wire leads into the correct holes in the DC power connector. Use the labels above the DC power connector as a guide to positive, negative, and ground connections. If the wire leads are plugged into the wrong holes, the power supply will not work properly and damage to the unit may result.

Push the wire in far enough such that it reaches the back wall of the connector, about a half inch inside.

page 3-16

+ -

Ground Wire

Attaching the Ground Wire

OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

4

Tighten the clamp by tightening the screw above the slot into which you inserted the wire lead. The wire lead should be securely attached inside the connector. You should be able to pull on the wire and not dislodge it.

Warning. For DC input voltages, the positive (+) wire of the sourcing equipment, such as a battery or rectifier, must be connected to the positive (+) terminal of the OmniSwitch DC power supply and the negative (-) wire of the sourcing equipment must be connected to the negative (-) terminal of the

OmniSwitch DC power supply."

5

Repeat Steps 2 through 4 for the remaining positive and negative wire leads.

OS6850E Power Sup-

DC Power Source

Correct Polarity Connections

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 3-17

OmniSwitch 6850E Series Power Supplies OmniSwitch 6850E Series Power Supplies

Viewing the Power Supply Status

The switch constantly monitors the power supply operation. If either the primary or backup power source

(optional) unexpectedly shuts down, the switch sends out a notification to the user. In addition, the power

LED on the chassis front panel display solid amber.

Note. For detailed LED information, refer to “Status LEDs” on page 2-54 .

To check the number of power supplies currently operating, and the status of each power supply, use the show power command. For example:

-> show power

Power Supplies in chassis 1

PS Operational Status

---------+-------------------

PS-1 UP

PS-2 NOT PRESENT

The primary (i.e., factory-installed) power supply is listed as PS-1 in the show power command output.

The backup power supply is listed as PS-2. In the example above, there is no backup power supply installed.

page 3-18 OmniSwitch 6850E Series Hardware Users Guide

January 2013

OmniSwitch 6850E Series Power Supplies Monitoring the Chassis

Monitoring the Chassis

OmniSwitches can be monitored and managed via the console port using Command Line Interface (CLI) commands. The switches can also be monitored and managed via the Ethernet using CLI commands,

WebView, SNMP, and OmniVista.

The section below provides some examples of useful hardware-related monitoring CLI commands. Refer to the OmniSwitch CLI Reference Guide for detailed information on all management and monitoring commands used with the OmniSwitch.

Checking the Overall Chassis Status

To check the overall status of a chassis, including the chassis type, and current administrative and operational status, use the show chassis command. For example:

-> show chassis

Chassis 1

Model Name: OS6850-48,

Description: 10/100/1000,

Part Number: 902274-10,

Hardware Revision: 005,

Serial Number: 439L0024,

Manufacture Date: SEP 22 2005,

Admin Status: POWER ON,

Operational Status: UP,

Number Of Resets: 1

For a complete list of output definitions for this command, refer to the OmniSwitch CLI Reference Guide.

Checking the Temperature Status

To check chassis temperature status, including the current temperature and configured threshold values, use the show temperature command. For example:

-> show temperature

Temperature for chassis 1

Hardware Board Temperature (deg C) = 38,

Hardware Cpu Temperature (deg C) = N/A,

Temperature Upper Threshold Range (deg C) = 30 to 72,

Temperature Upper Threshold (deg C) = 57,

Temperature Range = UNDER THRESHOLD,

Temperature Danger Threshold (deg C) = 72

For a complete list of output definitions for this command, refer to the OmniSwitch CLI Reference Guide.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 3-19

Monitoring the Chassis OmniSwitch 6850E Series Power Supplies

Checking the Fan Status

To check the current status for all six fans in the chassis, use the show fan command. For example:

-> show fan

Chassis Fan Status

-------+---+-----------

1 1 Running

1 2 Running

1 3 Running

1 4 Running

1 5 Running

1 6 Running

For a complete list of output definitions for this command, refer to the OmniSwitch CLI Reference Guide.

Checking the Power Supply Status

For information on checking power supplies, refer to “Viewing the Power Supply Status” on page 3-18 .

Additional Monitoring Commands

CLI Commands Used for Monitoring a Chassis show cmm show ni show module show module long show module status

Displays the basic hardware and status information for primary and secondary management modules (if applicable).

Displays the basic hardware and status information for individual modules. If the switch is a standalone, information for the stand alone switch displays.

Displays the basic information for individual modules. If the switch is a standalone, information for the stand-alone switch displays.

Displays the detailed information for individual modules. If the switch is a standalone, information for the standalone switch displays.

Displays the basic status information for individual modules. If the switch is a standalone, information for the standalone switch displays.

page 3-20 OmniSwitch 6850E Series Hardware Users Guide

January 2013

4 OmniSwitch Backup Power

Shelf/System (BPS)

The OmniSwitch Backup Power Shelf/System (BPS) is a stackable power shelf that provides primary and backup system and PoE power to stacks of up to eight OS6850E switches.

A maximum of two system power supplies and three POE power supplies can be installed in a single

OS-BPS chassis. If two or more like power supplies are installed, each will share the power load.

OS-BPS Chassis Rear

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OS-BPS Chassis Front

page 4-1

Chassis Details OmniSwitch Backup Power Shelf/System (BPS)

Chassis Details

OmniSwitch Backup Power Shelf/System (BPS) Front Panel

A B C D E

F

Item

A - C

D and E

F

Description

PoE Power Supply Bays

System Power Supply Bays

Removable Mounting Plate

OmniSwitch Backup Power Shelf/System (BPS) Rear Panel

A B

C1

C B

C3

C B

C5

C B

C8

C7

D

C2 C4 C6 C8

OmniSwitch BPS

OK

C2 C4 C6

Item

A

B

C

D

Description

Chassis Grounding Lug

DB25 Power Connectors (providing system and PoE power to OS6850E switches)

Power Cord Connectors for PoE Power Supplies

Chassis LEDs

Supported Platforms

The OmniSwitch BPS supports OS6850E-24, OS6850E-P24, OS6850E-24X, OS6850E-P24X,

OS6850E-48, OS6850E-P48, OS6850E-48X and OS6850E-P48X switches.

Note. Please note that OS6850E-U24X models are not supported. Also, earlier OS6850 Series switches are not supported and will not operate when connected to an OS-BPS chassis.

page 4-2 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) Specifications

Specifications

OmniSwitch Backup Power Shelf/System (BPS) Chassis Specifications

Chassis Width (with brackets)

Chassis Width (without brackets)

Chassis Height

Overall Unit Height with Factory-Attached Mounting Plate

1

Overall Chassis Depth

Chassis Weight (empty)

Chassis Weight (fully populated)

2

System Power Supply Bays

PoE Power Supply Bays

Compatible Power Supplies (System Power)

Compatible Power Supplies (PoE Power)

Maximum Power (PoE)

Maximum Power (System)

3

Operating Temperature (Tmra):

Storage Temperature

Humidity (Operating)

Humidity (Non-Operating)

48.2 cm (19 inches)

43.3 cm (17.05 inches)

4.4 cm (1.73 inches or 1RU)

6.67 cm (2.625 inches or 1.5RU)

46.04 cm (18.125 inches)

4.4 kg (9.68 lbs)

12.85 kg (28.34 lbs)

2

3

OS-BPS-S (OS-PS-450W-A)

OS-BPS-P (CP2000AC54TEP-AL)

6000W

900W

0°C to 45°C (32°F to 113°F)

-10°C to +70°C (14°F to 158°F)

5% to 95% non-condensing

5% to 95% non-condensing

1

The OmniSwitch Backup Power Shelf/System (BPS) ships with a factory-attached mounting plate that can be removed onsite to reduce the overall unit height to 1RU.

2

Fully populated weight includes all installable power supplies.

3

900W system power requires two 450W OS-BPS-S power supplies to be installed and operating in the

OS-BPS chassis.

*Note On Chassis Versus Ambient Temperatures. Chassis temperature refers to the sensor reading of the internal chassis temperature (threshold or danger). Ambient temperature refers to the temperature of the room and are approximations. The ambient temperature will be less than the chassis temperature and will vary for each model due to different airflow characteristics.

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-3

Chassis Status LEDs OmniSwitch Backup Power Shelf/System (BPS)

Power Supply Redundancy

Power supplies installed in the same OS-BPS chassis may operate in a redundant or backup configuration by sharing the same electrical load with another power supply.

Hot Swapping

OS-BPS power supplies are hot swappable. If redundant power supplies are operating in the chassis, a power supply can be removed or replaced without adversely affecting normal operation. New power supplies may be inserted in empty power supply slots at any time.

Considerations if OS-BPS is the Only Power Source In a Stack

If the primary power supply fails on any switch connected to the OS-BPS, leaving the OS-BPS as the switch's only power source, it is recommended that the primary power supply is replaced on the switch as soon as possible.

If the primary power supply fails on any PoE-enabled switch connected to the OS-BPS and the switch must be powered down, the PoE power must first be disabled on the switch using the lanpower stop CLI command before disconnecting the DB25 connector between the OS-BPS and the switch.

Chassis Status LEDs

The chassis provides a series of status LEDs located on the front panel. These LEDs offer basic status information for hardware operation and port link and activity status.

LED

OK

C1 - C8

ECO LED

State

Solid Green

Blinking Amber

Solid Green

Solid Amber

TBD

Description

Operational

In transitional state (e.g. performing diagnostics or booting)

Both power supplies are functional

One power supply is functional

TBD page 4-4 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) Chassis Status LEDs

OS-BPS Connector Priority

If the total available PoE or system power drops below the minimum budget required for the current configuration, the OS-BPS automatically powers off switches according to priority until the configuration falls within the available power budget.

If the total available PoE or system power later increases to meet the power demands of the configuration, the OS-BPS returns power to those switches based on priority.

Connector priority for all OS-BPS connectors is user configurable. This allows the user to specify which switches will remain operational in the event of a power budget shortfall.

By default, connector 1 receives the highest priority and connector 8 receives the lowest priority.

Additional default priorities are specified below.

Connector

Default Priority

1

8

2

7

3

6

4

5

5

4

6

3

7

2

8

1

Note. The higher the numerical priority value, the higher the connector priority.

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-5

Mounting the Chassis OmniSwitch Backup Power Shelf/System (BPS)

Mounting the Chassis

General Mounting Recommendations

Elevated Operating Ambient Temperature. If installed in a closed or multi-rack assembly, the operating ambient temperature of the rack environment may be greater than the room’s ambient temperature.

Therefore, consideration should be given to the maximum rated ambient temperature (Tmra) specified on

page 4-3 .

Reduced Air Flow. Installation of the equipment in a rack should be such that the amount of air flow

required for safe operation of the equipment is not compromised. Refer to “Airflow Recommendations” on page 4-6 for more information.

Mechanical Loading. Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven loading.

Circuit Overloading. Consideration should be give to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on overcurrent protection and supply wiring.

Reliable Earthing. Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch (e.g., use of power strips).

Airflow Recommendations

To ensure proper airflow, the OS-BPS should be placed in a well-ventilated area with minimum recommended clearance at front, back and sides of the chassis. (Clearance is not required at the top and bottom of the chassis.) Restricted airflow can cause the chassis to overheat, which can lead to system failure. Refer to the following important guidelines regarding airflow:

}

Rear. 6 inches minimum at rear of chassis.

Sides. 2 inches minimum at left and right sides.

}

Front. 6 inches minimum at front of chassis.

Chassis Top View

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-6

OmniSwitch Backup Power Shelf/System (BPS) Mounting the Chassis

OmniSwitch BPS Airflow

The OmniSwitch Backup Power Shelf/System (BPS) power supplies are installed in power supply bays located at the front of the chassis. Each power supply draws air through intake vents at the front of the power supply. The air is then directed straight through each power supply and out the rear chassis vent.

OmniSwitch BPS Airflow

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-7

Mounting the Chassis OmniSwitch Backup Power Shelf/System (BPS)

Blank Cover Panels

Blank cover panels are provided with your chassis and are used to cover empty slots. These cover panels play an important role in chassis airflow and temperature management. If your chassis is not fully populated and blank cover panels are not installed over empty slot locations, airflow is affected.

When blank cover panels are missing, air does not take the direct route from the power supply air intake vents, through the power supply body, and out through the chassis exhaust vent as intended. Instead, a portion of the airflow is allowed to escape through other openings in the chassis. As a result, normal airflow is disrupted and an extra task is placed on the system to cool the chassis.

Note. Because they regulate airflow and help protect internal chassis components, blank cover panels should be installed over empty power supply bays at all times.

page 4-8

Blank Panels and Chassis Airflow

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) Rack-Mounting

Rack-Mounting

Refer to the following important guidelines before installing the chassis in a rack:

Two people are required to rack mount the chassis: One person to lift the chassis into position and one person to secure the chassis to the rack using the rack mount screws.

The chassis has rack-mount flanges that support standard 19-inch rack mount installations.

Alcatel-Lucent does not provide rack-mount screws. Use the screws supplied by the rack vendor.

To prevent a rack from becoming top heavy, it is recommended that you install the chassis at the bottom of the rack whenever possible.

If you are installing the chassis in a relay rack, be sure to install and secure the rack per rack manufacturer’s specifications.

Note. Never rack mount the chassis using only the front-installed rack mount flanges. Due to the chassis depth and overall weight, it must be mounted using front and rear flanges (as described below) or by attaching flanges to the mid portion of the chassis (see “Mid-Mounting the Chassis In the Rack” on page

4-10). Failure to properly mount the chassis may result in the chassis sagging in the rack or damage to the chassis and its components.

To rack mount the chassis, follow the steps below.

1 Mark the holes on the rack where the chassis is to be installed.

2

One person should lift and position the chassis until the rack-mount flanges are flush with the rack post.

3 Align the holes in the flanges with the rack holes marked in step 1.

4

Once the holes are aligned, the second person should insert a screw through the bottom hole on each flange. Tighten both screws until they are secure.

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-9

Rack-Mounting OmniSwitch Backup Power Shelf/System (BPS)

5

Insert the remaining rack-mount screws through the empty holes in the flange and tighten.

6

Next, secure the back of the chassis to the rear rack posts. With the flanges facing out, insert the slidein braces into the slot rails until they meet the rear rack posts.

Note. The chassis installation should be level. Be sure that the rear flanges are aligned with the corresponding holes at the front of the rack.

7 Insert rack mount screws through the rear rack mount flanges and tighten.

page 4-10 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) Rack-Mounting

Mid-Mounting the Chassis In the Rack

The chassis may also be installed in the rack using mid-mount flanges. To mid-mount the chassis in a rack, follow the steps below.

1

If applicable, remove the factory-installed front mounting plate and slot rails from the side of the chassis by loosening and removing the attachment screws.

Remove

Remove

Remove

2

Install the individual mounting brackets at the midpoint of the chassis using the four threaded holes on each side.

3 Mark the holes on the rack where the chassis is to be installed.

4

One person should lift and position the chassis until the mid-mount flanges are flush with the rack post.

5 Align the holes in the flanges with the rack holes marked in step 3.

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-11

Rack-Mounting OmniSwitch Backup Power Shelf/System (BPS)

6

Once the holes are aligned, the second person should insert a screw through the bottom hole on each flange. Tighten both screws until they are secure.

7

Once the flanges are aligned, install the remaining screws. Be sure that all screws are securely tightened.

page 4-12 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) Power Supplies

Power Supplies

OmniSwitch Backup Power Shelf/System (BPS) power supplies are located at the front of the chassis.

Refer to page 4-2 for more information on component locations. Two system power supply bays and three

PoE power supply bays are provided.

Note. For PoE installations, a minimum of one system power supply and one PoE power supply are required to power up a single OS-BPS.

Please note that the power supplies do not provide an on/off switch. Connecting an installed power supply to a power source will power on the power supply. Likewise, disconnecting all installed power supplies from a power source will power off the chassis.

AC Power Supply

Status LED

Lock Tab

Air Vent

Handle

AC Connector

Model

Input Voltage Range

Nominal Voltage

Max. Power

Input Current

Output Rating

Operating Temperature

Storage Temperature

Humidity (Operating)

Humidity (Non-Operating)

Airflow

AC Power Supply Front Panel

OS-BPS-S (OS-PS-450W-A)

100-240VAC, 50-60Hz

115 VAC; 230 VAC

450W

8A (100-132V); 4A (180-264V)

12V@37A

0°C to 50°C

-40°C to +70°C

5% to 95% non-condensing

5% to 95% non-condensing

This power supply provides front-to-back airflow only for

OS-BPS applications. See “Airflow Recommendations” on page 4-6

for more information.

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-13

Power Supplies OmniSwitch Backup Power Shelf/System (BPS)

AC Power Supply LED States

LED State

Solid Green

Flashing Green

Flashing Red

Flashing Green/Red

Solid Red

Off

Description

The power supply is operating normally and providing power to the chassis

The power supply is on standby and can provide power to the chassis if power supply failover should occur

No AC power is being provided to this power supply

Power supply warning

Power supply failure

No AC power is being provided to any power supply installed in the chassis; all power supplies are effectively off page 4-14 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS)

OmniSwitch BPS PoE Power Supply

Power Supplies

Model

Input Voltage Range

Nominal Voltage

Max. Power

Input Current

Output Rating

Operating Temperature

Storage Temperature

Humidity (Operating)

Humidity (Non-Operating)

Airflow

Update - PoE Power Supply Front Panel

OS-BPS-P (CP2000AC54TEP-AL)

100-132VAC; 180-264VAC

115 VAC; 230 VAC

1200W (115 VAC); 2000W (230 VAC)

15 (100VAC); 12 (120VAC); 11 (200-240VAC)

54.5V@A

-5°C to 50°C

-40°C to +85°C

5% to 95% non-condensing

5% to 95% non-condensing

This power supply provides front-to-back airflow only.

See “Airflow Recommendations” on page 4-6

for more information.

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-15

Power Supplies OmniSwitch Backup Power Shelf/System (BPS)

OmniSwitch BPS PoE Power Supply LED States

LED Description

On: Input OK

Blinking: Input out of limits

On: Output OK

Blinking: Power supply overload

On: Over-temp warning

Blinking: Service

ON: Fault page 4-16 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) OmniSwitch BPS Power Connections

OmniSwitch BPS Power Connections

Connecting the OmniSwitch BPS to OS6850E Switches

System and PoE power are provided to each OS6850E through a single one meter DB25 connector cable.

Up to eight switches may be connected to the OmniSwitch BPS chassis. To connect a switch to the

OS-BPS chassis, follow the steps below.

1

Attach one end of the cable to the DB25 connector on the rear of the OS-BPS.

2 Next, attach the other end of the cable to the DB25 connector on the rear of the switch chassis.

Note. When connecting stacked switches to the OS-BPS, note that the switch connected to connector port

“C1” will have the highest power budget priority; the switch connected to connector port “C2” will have the next highest priority, etc. For additional information, refer to

“OS-BPS Connector Priority” on page 4-5 for more information.

OS6850E DB25 Connector

OmniSwitch BPS DB25 Connector

1 Meter Connector Cable

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-17

OmniSwitch BPS Power Connections OmniSwitch Backup Power Shelf/System (BPS)

Installing and Connecting System Power

1 Orient the power supply so that the power cord socket is situated at the right of the power supply. Also, for the power supply to seat properly, make sure that the handle is in the vertical position.

2

Slide the power supply back until it is securely seated in the chassis backplane.When the connector is fully seated, the lock tab will click and hold the power supply in place.

3

Plug the power cord (provided) into the power supply’s socket.

Note. The chassis does not provide an on/off switch. Connecting a minimum of one system power supply and one PoE power supply to a power source will power on the OS-BPS chassis and any attached switches.

page 4-18 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) OmniSwitch BPS Power Connections

Installing PoE Power Supplies

1 Orient the power supply so that the lever locking tab is situated at the right of the power supply with the lever open.

2 Slide the power supply back until the left side of the lever catches the sheet metal tab at the inside top of the chassis. Gently close the lever until it locks into place securing the power supply into the chassis.

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-19

OmniSwitch BPS Power Connections OmniSwitch Backup Power Shelf/System (BPS)

Connecting PoE Power

1 Insert the power cord connector into the socket at the rear of the chassis.

2

Use the retainer clip to secure the power cord to the connector.

Note. The chassis does not provide an on/off switch. Connecting a minimum of one system power supply and one PoE power supply to a power source will power on the OS-BPS chassis and any attached switches.

page 4-20 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) Grounding the Chassis

Grounding the Chassis

The chassis has a grounding lug located on the rear of the chassis. This lug uses 10-32 screws and is surrounded by a small paint-free area, which provides metal-to-metal contact for a ground connection.

Use this connector to supplement the ground provided by the AC power cord. To do so, install a Panduit

Grounding Lug (type LCD8-10A-L) using 8AWG copper conductors to the paint-free area.

Additionally, ensure that all AC sources used to power the OS-BPS and the OmniSwitches share a common electrical ground. The “Earth Ground” for all AC sources must be a solid common ground that does not have any electrical potential (voltage) between them.

Refer to the rear chassis views on

page 4-2

for location details.

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-21

Disconnecting a Chassis from the OS-BPS OmniSwitch Backup Power Shelf/System (BPS)

Disconnecting a Chassis from the OS-BPS

When disconnecting an OS6850E switch from the OS-BPS, first disconnect the DB25 connector cable between the OS-BPS and the switch, then disconnect the primary power supply for the

OS6850E.

Note. If the primary power supply fails on any PoE-enabled switch connected to the OS-BPS and the switch must be powered down, the PoE power must first be disabled on the switch using the lanpower stop CLI command before disconnecting the DB25 connector between the OS-BPS and the switch.

Removing System Power Supplies

1 When removing a power supply, first disconnect the power cord from the power source. Once the power cord is disconnected, pull the power cord out of the power supply housing.

2

Pressing the lock tab toward the right, as shown, will free the power supply from the chassis. While pressing the lock tab, pull the power supply straight back and out of the chassis slot.

Lock Tab

Note. If you are not replacing the power supply, be sure to install a blank cover panel over the empty power supply bay.

page 4-22 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) Disconnecting a Chassis from the OS-BPS

Removing PoE Power Cords from the OS-BPS Chassis

1 Swing the retainer clip away from the power cord connector.

2 Pull the cord straight out of the connector socket.

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-23

Disconnecting a Chassis from the OS-BPS OmniSwitch Backup Power Shelf/System (BPS)

Removing PoE Power Supplies

1 When removing a power supply, first disconnect the power cord from the power source. Once the power cord is disconnected, pull the power cord out of the power supply housing.

2

Pressing the lock tab toward the right, as shown, will free the lever. Pull the lever to release the power supply from chassis, pull the power supply straight back and out of the chassis slot.

Lock Tab

Note. If you are not replacing the power supply, be sure to install a blank cover panel over the empty power supply bay.

page 4-24 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) Monitoring OmniSwitch BPS Components

Monitoring OmniSwitch BPS Components

The following commands have been added or modified for OmniSwitch BPS support on OS6850E switches.

Viewing General Power Supply Information

To display all system power supplies, including those installed in the OmniSwitch BPS chassis, enter the following command:

-> show power supply

To display only power supplies currently installed in the OmniSwitch BPS chassis, enter the following command:

-> show power supply bps

To display the connector priority for power supplies currently installed in the OmniSwitch BPS chassis, enter the following command:

-> show power bps connector-priority

Note. For more detailed information on these commands, as well as OmniSwitch BPS configuration commands, refer to the OmniSwitch CLI Reference Guide.

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-25

OmniSwitch BPS Operation OmniSwitch Backup Power Shelf/System (BPS)

OmniSwitch BPS Operation

The amount of power supplied by the OS-BPS depends on the number of system and/or PoE power supplies installed as noted in the table below:

1 System P/S (450W)

2 System P/S (900W)

1 PoE P/S

2 PoE P/S

3 PoE P/S

Can support up to 4 OS6850E primary power supply failures.

Can support up to 8 OS6850E primary power supply failures.

Can support up to1200W (low line) or 2000W (high line) of PoE power.

Can support up to 2400W (low line) or 4000W (high line) of PoE power.

Can support up to 3600W (low line) or 6000W (high line) of PoE power.

Single Mode (N+1)

When configured in single mode the OS-BPS power is unmanaged, meaning all the installed system power supplies act as a single redundant system power supply and all the installed PoE power supplies act a single redundant PoE power supply to provide backup power. There is no priority given to any connector, the OS-BPS will continue to provide power as long as the amount of power required by the OmniSwitches is less than the total power available on the OS-BPS. The number of OmniSwitch primary power supplies that can fail but still have redundant system power supplied by the OS-BPS depends on the number of OS-

BPS system power supplies installed. PoE coverage is dependent on PoE power usage. Multiple power failovers will only be supported for PoE if the total current draw is less than available PoE power on the

OS-BPS.

Full Mode (N+N)

When configured in full mode the OS-BPS power is managed, meaning if the power requirements of the switches becomes greater than what the OS-BPS can provide, the OS-BPS will manage the power and begin to shut down power based on connector priority. For additional information on connector priority refer to

“OS-BPS Connector Priority” on page 4-5

for more information.

Note. Do not change the power mode while the OS-BPS is providing power.

Changing the OS-BPS Mode

To change the mode that the OS-BPS is operating in us the power bps mode command:

-> power bps mode full page 4-26 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

OmniSwitch Backup Power Shelf/System (BPS) OmniSwitch BPS Operation

OmniSwitch BPS Configurations

The OmniSwitch BPS can be used to provide redundancy to the OmniSwitch 6850E in multiple configurations as described below:

Supported Configurations

Single stack (from 1 to 8 switches)

1 to 8 non-stacked switches

Two stacks of switches (up to 4 switches each)

Unsupported Configurations

Partial stack (only NIs are connected to OmniSwtich BPS, but not the CMM)

A mix of stacked and unstacked switches

OmniSwitch Backup Power Shelf/System (BPS)

January 2013

page 4-27

OmniSwitch BPS Operation OmniSwitch Backup Power Shelf/System (BPS)

OmniSwitch BPS Scenarios

The tables below describe scenarios that can be seen when using the OS-BPS and what the expected behavior will be based on the mode of the OS-BPS.

System Power Scenarios

System P/S Scenario Single (N+1) Mode Full (N+N) Mode

No System power on OS-

BPS.

No redundant system power available. No redundant system power available.

One system power supply in OS-BPS while primary power supply is in use.

Two system power supplies in OS- BPS while primary power supply is in use.

Removal of a stack element

Up to 4 switches can be supported.

Up to 8 switches can be supported.

No change

Connectors 1-4 will be enabled and ready to provide redundant power.

Connectors 5-8 will be enabled and ready to supply redundant power.

No change

Adding a stack element with OS-BPS in use and one system power supply.

Adding a stack element with OS-BPS in use and two system power supplies.

If 4 or less switches then there is no change. If 5 or more switches then the system power will shut down.

Connectors 1-4 will be enabled, switches connected to 5-8 will not be powered up.

New element powered on. New element powered on.

Power over Ethernet Scenarios

PoE P/S Scenario Single (N+1) Mode

No PoE power available on OS-BPS.

Redundant PoE power will not be available. PoE will drop upon failure of a primary power supply.

A PoE power supply is added to the OS-BPS when the primary power supply is in use.

No immediate change but more PoE power will be available if a primary power supply fails.

A PoE power supply is added when OS-BPS is in use.

No immediate change but more PoE power will be available if a primary power supply fails.

Removal of a stack element

No change

Full (N+N) Mode

Redundant PoE power will not be available. PoE will drop upon failure of a primary power supply.

Amount of managed PoE power available will be increased.

Amount of managed PoE power available will be increased.

Amount of managed PoE power available will be increased.

Addition of a stack element with OS-BPS in use.

If new PoE power requirement is greater than available PoE power then

PoE will be shut down.

Amount of managed PoE power available will be decreased and PoE will be shut down based on connector priority if required.

page 4-28 OmniSwitch Backup Power Shelf/System (BPS)

January 2013

5 Managing Power over

Ethernet (PoE)

Power over Ethernet (PoE) provides inline power directly from the switch’s Ethernet. Powered Devices

(PDs) such as IP phones, wireless LAN stations, Ethernet hubs, and other access points can be plugged directly into the Ethernet. From these RJ-45 the devices receive both electrical power and data flow.

As the feature reduces devices’ dependence on conventional power sources, PoE eliminates many restrictions that traditional electrical considerations have imposed on networks.

In a PoE configuration, Power Source Equipment (PSE) detects the presence of a PD and provides an electrical current that is conducted along the data cable. The PD operates using the power received via the

Ethernet data cable; no connection to an additional power source (e.g., an AC wall socket) is required.

Note on Terminology. There are several general terms used to describe the feature, PoE. The terms Power over Ethernet (PoE), Power over LAN (PoL), Power on LAN (PoL), and Inline Power are synonymous terms used to describe the powering of attached devices via Ethernet. For consistency, this chapter and the

CLI Command Reference Guide refer to the feature as Power over Ethernet (PoE).

Additional terms, such as Powered Device (PD) and Power Source Equipment (PSE) are not synonymous with PoE, but are directly related to the feature:

PD refers to any attached device that uses a PoE data cable as its only source of power. Examples include access points, such as IP telephones, Ethernet hubs, wireless LAN stations, etc.

PSE refers to power sourcing equipment, which provides power to a single link section. PSE main functions include searching the PD, optionally classifying the PD, supplying power to the link section only if the PD is detected, monitoring the power on the link section, and scaling power back to detect level when power is no longer requested or required.

As the switches fully support 10/100/1000 Ethernet connectivity, you may also attach non-PD equipment, such as computer workstations, printers, servers, etc. to the PoE ports.

Important. Alcatel-Lucent recommends that PoE-enabled switches with attached IP telephones should have operational power supply redundancy at all times for 911 emergency requirements. In addition, both the switch and the power supply should be plugged into an Uninterruptible Power Source (UPS).

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 5-1

In This Chapter Managing Power over Ethernet (PoE)

In This Chapter

This chapter provides specifications and descriptions of hardware and software used to provide PoE for attached devices.

The chapter also provides information on configuring PoE settings on the switch through the Command

Line Interface (CLI). CLI commands are used in the configuration examples; for more details about the syntax of commands, see the OmniSwitch CLI Reference Guide. Topics and configuration procedures described in this chapter include:

Power over Ethernet Specifications on page 5-3

Viewing Power Status on page 5-4

Configuring Power over Ethernet Parameters on

page 5-5

Understanding Priority Disconnect on page 5-9

Monitoring Power over Ethernet via the CLI on page 5-12

Note. You can also monitor all chassis components and manage many chassis features, including Power over Ethernet, with WebView, Alcatel-Lucent’s embedded web-based device management application.

WebView is an interactive and easy-to-use GUI that can be launched from the OmniVista or a web browser. Please refer to WebView’s Online Documentation for more information.

page 5-2 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing Power over Ethernet (PoE) Power over Ethernet Specifications

Power over Ethernet Specifications

The table below lists general specifications for Alcatel-Lucent’s Power over Ethernet support. For more

detailed power supply and Power Source Equipment (PSE) specifications, refer to Chapter 3,

“OmniSwitch 6850E Series Power Supplies.”

IEEE Standards supported

PoE Class Detection

Default PoE administrative status

Default PoE operational status

IEEE 802.3at

Supported

Enabled

Disabled (PoE must be activated on a switchby-switch basis via the lanpower start command.)

Platforms supporting PoE PoE Models

Default amount of inline power available for each port 30000 milliwatts

Range of inline power allowed for each port

Default amount of PoE power per slot

Maximum PoE power per slot

3000-30000 milliwatts

510W power supply - 390W

360W power supply - 240W

900W power supply - 780W

510W power supply - 390W

360W power supply - 240W

900W power supply - 780W

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 5-3

Viewing PoE Power Supply Status Managing Power over Ethernet (PoE)

Viewing PoE Power Supply Status

To view the current status of power supplies installed in the backup power supply, use the show power command, as shown below:

-> show power

Slot PS Wattage Type Status Location

----+----+---------+------+-----------+----------

1 1 -- -- -- --

1 2 360 AC UP External

1 3 -- -- -- --

2 1 510 AC UP External

2 2 -- -- -- --

2 3 -- -- -- --

3 1 360 AC UP External

3 2 -- -- -- --

3 3 -- -- -- --

The backup power supply will always display as “PS-2”. For detailed information on the show power command output, refer to the CLI Command Reference Guide.

page 5-4 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing Power over Ethernet (PoE) Configuring Power over Ethernet Parameters

Configuring Power over Ethernet Parameters

Power over Ethernet Defaults

The following table lists the defaults for PoE configuration:

Parameter Description Command(s) Default Value/Comments

PoE operational status lanpower start or lanpower stop Disabled

Total power available to a port lanpower power

See Chapter 5, “Managing

Power over Ethernet (PoE).”

Total power available to an entire slot lanpower maxpower

See Chapter 5, “Managing

Power over Ethernet (PoE).”

Power priority level for a port lanpower priority

Capacitor detection method lanpower capacitor-detection

Priority disconnect status lanpower priority-disconnect low

Disabled

Enabled

Understanding and Modifying the Default Settings

The sections below provide information on each of the key components within the Power over Ethernet software. They include information on PoE-related CLI commands. For detailed information on PoErelated commands, refer to the OmniSwitch CLI Reference Guide.

Note. PoE units support different wattage power supplies. If unlike power supplies are mixed or if an unsupported power supply (such as a 120W power supply) is used, a console message and a trap are generated.

PoE Class Detection

Powered devices can be classified into different classes as shown in the table below. Class detection allows for automatic maximum power adjustment based on the power class detected. This will prevent the switch from delivering more than the maximum power allowed based on a device’s class.

During class detection the switch will allocate the maximum amount of power allowed based on the class detected. Once powered, if the device uses less than the maximum the remaining power will be made available for other devices.

Class

2

3

4

0

1

Usage

Classification

Default

Optional

Optional

Optional

Optional

Current (mA)

Power Range

(Watts)

Class Description

0-4

9-12

17-20

26-30

36-44

0.44-30.00

0.44-3.84

Unimplemented

Very Low Power

3.84-6.49

6.49-12.95

Low Power

Mid Power

12.95- 30.00

High Power

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 5-5

Configuring Power over Ethernet Parameters Managing Power over Ethernet (PoE)

Setting the PoE Operational Status

Enabling PoE

By default, Power over Ethernet is administratively enabled in the switch’s system software. However, in order to physically activate PoE, you must issue the lanpower start command on a slot-by-slot basis before any connected PDs will receive inline power.

To activate power to PoE-capable in a switch, enter the corresponding slot number only. For example:

-> lanpower start 3

If power to a particular port has been disconnected via the lanpower stop command, you can reactivate power to the port by specifying both the slot and port in the command line. For example:

-> lanpower start 3/11

Note. You cannot use the slot/port syntax to initially activate PoE on a port. This syntax is intended only to reactivate power to those that have been disconnected via the lanpower stop command. To initially activate PoE, you must use the lanpower start slot syntax only, as described above.

Disabling PoE

To disable PoE on a particular slot or port, use the lanpower stop command.

To disable PoE on a specific PoE-capable port, enter a slot/port number. For example:

-> lanpower stop 8/22

To disable PoE for all PoE-capable in a slot, enter the corresponding slot number only.

For example:

-> lanpower stop 8

Configuring the Total Power Available to a Port

By default, each port is authorized by the system software to use up to a maximum amount of milliwatts to power any attached device.

You can either increase or decrease this value based on the allowed ranges specified in

Chapter 5,

“Managing Power over Ethernet (PoE).”

Increasing the total power available to an individual port may provide a more demanding Powered Device

(PD) with additional power required for operation. Decreasing the total power available to a port helps to preserve inline power and assists in the overall management of the switch’s power budget.

To increase or decrease the total power available to an individual port, use the lanpower power command.

Since you are setting the power allowance for an individual port, you must specify a slot/port number in the command line. For example, the syntax

-> lanpower 3/12 power 3000 reduces the power allowance on slot 3 port 12 to 3000 milliwatts. This new value is now the maximum amount of power the port can use to power any attached device (until the value is modified by the user).

page 5-6 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing Power over Ethernet (PoE) Configuring Power over Ethernet Parameters

Configuring the Total Power Available to a slot

Like the maximum port power allowance, the system software also provides a maximum slot-wide power allowance. By default, each slot is authorized by the system software to use a number of watts to power all devices connected to its ports depending on which power supply is used.

As with the maximum port power allowance, the user can either increase or decrease this value based on the allowed ranges specified in

Chapter 5, “Managing Power over Ethernet (PoE).”

Note: Increasing or decreasing the total power available to a slot is designed for use on chassis-based products which share PoE power among the slots. For stackable products this command has no affect on other stack elements since each switch has a dedicated power supply.

Important. Decreasing the slot-wide power could cause lower priority ports to lose power if the new value is less than the total PoE power currently being consumed.

To increase or decrease the total power available to a slot, use the lanpower maxpower command. Since you are setting the power allowance for an individual slot, you must specify a slot number in the command line. For example, the syntax

-> lanpower 3 maxpower 80 reduces the power allowance of slot 3 to 80 watts. This value is now the maximum amount of power the slot can use to power all attached devices (until the value is modified by the user).

Note. Changing the maximum power available to a slot or port does not reserve or immediately allocate that power. These settings are only used for configuring a maximum amount of power that may be used, any unused power is still available and remains a part of the overall PoE budget.

Setting Port Priority Levels

As not all Powered Devices (PDs) connected to the switch have the same priority within a network setting, the OmniSwitch allows the administrator to specify priority levels on a port-by-port basis. Priority levels include low, high, and critical. The default priority level for a port is low.

Low. This default value is used for port(s) that have low-priority devices attached. In the event of a power management issue, inline power to low-priority is interrupted first (i.e., before critical and highpriority).

High. This value is used for port(s) that have important, but not mission-critical, devices attached. If other ports in the chassis have been configured as critical, inline power to high-priority is given second priority.

Critical. This value is used for port(s) that have mission-critical devices attached, and therefore require top (i.e., critical) priority. In the event of a power management issue, inline power to critical is maintained as long as possible.

To change the priority level for a particular port, use the lanpower priority

command. Since the switch allows you to set priority levels on a port-by-port basis, be sure to specify slot/port information in the command line. For example, the syntax

-> lanpower 8/22 priority critical

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 5-7

Configuring Power over Ethernet Parameters Managing Power over Ethernet (PoE) changes the priority value of port 22 of the OmniSwitch slot 8 to the highest priority level of critical. Now that the default value has been reconfigured, this port should be reserved for those PDs that are mission critical for network operations.

Setting the Capacitor Detection Method

By default, the PowerDsine capacitor detection method is disabled. To enable it, use the lanpower capacitor-detection

command by entering lanpower capacitor-detection followed by the slot number of the switch and enable.

For example, to enable the capacitor detection method on the switch with slot number 2, enter:

-> lanpower capacitor-detection 2 enable

To disable it, use the lanpower capacitor-detection command by entering lanpower capacitor-detection followed by the slot number and disable.

For example, to disable the capacitor detection method on slot number 2, enter:

-> lanpower capacitor-detection 2 disable

Note. The capacitive detection method should only be enabled to support legacy IP phones. This feature is not compatible with IEEE specifications. Please contact your Alcatel-Lucent sales engineer or Customer

Support representative to find out which Alcatel-Lucent IP phones models need capacitive detection enabled.

page 5-8 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing Power over Ethernet (PoE) Understanding Priority Disconnect

Understanding Priority Disconnect

The priority disconnect function differs from the port priority function described on

page 5-7 in that it

applies only to the addition of powered devices (PDs) in tight power budget conditions. Priority disconnect is used by the system software in determining whether an incoming PD will be granted or denied power when there are too few watts remaining in the PoE power budget for an additional device. For example, if there are only 2 watts available in the current PoE power budget and a user plugs a 3.5W powered device into a PoE port, the system software must determine whether the device will be powered on. Based on priority disconnect rules, in some cases one or more existing devices may be powered down in order to accommodate the incoming device. In other cases, the incoming device will be denied power.

Priority disconnect rules involve the port priority status of an incoming device (i.e., low, high, and critical), as well as the port’s physical port number (i.e., 1–24). Understanding priority disconnect rules is especially helpful in avoiding power budget deficits and the unintentional shutdown of mission-critical devices when PDs are being added in tight power budget conditions. For detailed information on how priority disconnect uses port priority and port number criteria for determining the power status of incoming PDs, refer to the illustrated examples on pages

5-10 through

5-11 .

Reminder. Priority disconnect applies only when there is inadequate power remaining in the power budget for an incoming device.

For information on setting the priority disconnect status, refer to the section below. For information on setting the port priority status (a separate function from priority disconnect), refer to

“Setting Port Priority

Levels” on page 5-7

.

Setting Priority Disconnect Status

By default, priority disconnect is enabled in the switch’s system software. For information on changing the priority disconnect status, refer to the information below.

Disabling Priority Disconnect

When priority disconnect is disabled and there is inadequate power in the budget for an additional device, power will be denied to any incoming PD, regardless of its port priority status (i.e., low, high, and critical) or physical port number (i.e., 1–24).

To disable priority disconnect, use the lanpower priority-disconnect command. Since the switch allows you to set priority disconnect status on a slot-by-slot basis, be sure to specify the slot number in the command line. For example, the syntax

-> lanpower 2 priority-disconnect disable disables the priority disconnect function on slot 2.

Enabling Priority Disconnect

To enable priority disconnect, use the lanpower priority-disconnect command. Be sure to specify the slot number in the command line. For example, the syntax

-> lanpower 8 priority-disconnect enable enables priority disconnect on slot 8.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 5-9

Understanding Priority Disconnect Managing Power over Ethernet (PoE)

Priority Disconnect is Enabled; Same Priority Level on All PD

Reminder. Priority disconnect examples are applicable only when there is inadequate power remaining to power an incoming device.

When a PD is being connected to a port with the same priority level as all other in the slot, the physical port number is used to determine whether the incoming PD will be granted or denied power. Due to the support of different PoE standards and PoE hardware on each platform the internal port priority is different for each platform. The following tables should be used to determine PoE priority:

OS6850E Physical Port - 24 Port Models

OS6850E Physical Port - 48 Port Models

24 (Highest) -> 1 (Lowest)

48 (Highest) -> 1 (Lowest)

PoE Physical Port Priority

Priority Disconnect is Enabled; Incoming PD Port has Highest Priority Level

Reminder. Priority disconnect examples are applicable only when there is inadequate power remaining to power an incoming device.

When a PD is being connected to a port with a higher priority level than all other in the slot, the incoming

PD will automatically be granted power over the other devices, regardless of its physical port number.

In order to avoid a power budget deficit, another port in the slot is disconnected. In determining which port to power off, the system software first selects the port with the lowest configured priority level. For example, if a critical priority device is being added to a slot in which five existing devices are attached to high priority and one device is attached to a low priority port, the low priority port is automatically disconnected, regardless of its physical port number.

If all existing devices are attached to with the same lower priority level, the system software disconnects the port with both the lowest priority level and the highest priority physical port number. For example, if a critical priority device is being added to a slot in which six existing devices are attached to high priority, the high priority port with the lowest physical port priority number is automatically disconnected.

Priority Disconnect is Enabled; Incoming PD Port has Lowest Priority Level

Reminder. Priority disconnect examples are applicable only when there is inadequate power remaining to power an incoming device.

When a PD is being connected to a port with a lower priority level than all other in the slot, the incoming

PD will be denied power, regardless of its physical port number. Devices connected to other higher-priority will continue operating without interruption.

page 5-10 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing Power over Ethernet (PoE) Understanding Priority Disconnect

Priority Disconnect is Disabled

Reminder. Priority disconnect examples are applicable only when there is inadequate power remaining to power an incoming device.

When priority disconnect is disabled, power will be denied to any incoming PD, regardless of its port priority status (i.e., low, high, and critical) or physical port number (i.e., 1–24).

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 5-11

Monitoring Power over Ethernet via CLI Managing Power over Ethernet (PoE)

Monitoring Power over Ethernet via CLI

To monitor current PoE statistics and settings, use the show lanpower command. The command output displays a list of all current PoE-capable, along with the following information for each port:

Maximum power available to the port, in milliwatts

Actual power used by the port

Current port status

Power priority status

Power on/off status

Aggregate slot and chassis management information is also displayed. This information includes:

Maximum watts available to the corresponding slot

Amount of power budget remaining for PoE modules

Total amount of power remaining for additional switch functions

When entering the show lanpower command, you must include a valid slot number in the command line syntax. For example:

-> show lanpower 1

Port Maximum(mW) Actual Used(mW) Status Priority On/Off Class

----+-----------+---------------+-----------+---------+--------+-------

1 30000 12500 Powered On Low ON 0

2 30000 1800 Powered On Low ON 1

3 30000 3500 Powered On Low ON 2

4 30000 9800 Powered On Low ON 3

5 30000 25000 Powered On Low ON 4

6 30000 0 Undefined Low ON -

7 30000 0 Undefined Low ON -

8 30000 0 Undefined Low ON -

9 30000 0 Undefined Low ON -

(output truncated)

21 30000 0 Undefined Low ON -

22 30000 0 Undefined Low ON -

23 30000 0 Undefined Low ON -

24 30000 0 Undefined Low ON -

Slot 3 Max Watts 150

1 Power Supplies Available

Note. For detailed information on show lanpower command output, refer to the OmniSwitch CLI Reference Guide.

page 5-12 OmniSwitch 6850E Series Hardware Users Guide

January 2013

6 Managing OmniSwitch

6850E Series Stacks

In addition to their working as individual stand-alone switches, an OmniSwitch can also be linked together to work as a single virtual chassis known as a stack. With stacks, users can easily expand their switching capacity simply by adding additional switches to the stack. In addition, stacks provide enhanced resiliency and redundancy features.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-1

In This Chapter Managing OmniSwitch 6850E Series Stacks

In This Chapter

This chapter provides information on switches configured to operate as a single virtual chassis. Topics described in the chapter include:

OmniSwitch 6850E Series stack mode page 6-3 .

OmniSwitch 6850E Series stack overview on

page 6-4

.

Roles within the stack on page 6-4 .

Stack cabling on

page 6-17

.

Slot numbering on page 6-20 .

Hot-Swapping modules in a stack on page 6-25 .

Reloading switches on page 6-27

.

Changing the secondary module to primary on

page 6-35 .

Synchronizing switches in a stack on

page 6-37 .

Monitoring the stack on

page 6-38

.

Note. You can also manage and monitor stacks through WebView, Alcatel-Lucent’s embedded web-based device management application. WebView is an interactive and easy-to-use GUI that can be launched from OmniVista or a web browser. Please refer to WebView’s online documentation for more information.

page 6-2 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks OmniSwitch 6850E Series Stacking Specifications

OmniSwitch 6850E Series Stacking

Specifications

The following table lists OmniSwitch Stacking specifications.

Models Supporting Stacking

Maximum Switches in a Stack

Default Daughter Module Mode of

6850E

CX4 Stacking Cable Lengths

SFP+ Direct Attached Stacking Cable

Lengths

OmniSwitch 6850E

8

Stacking

30/60/150 cm

1/3/7 m

Changing OS6850E Daughter Module Mode

The OmniSwitch daughter module can be set to either stacking or uplink mode. The mode must be set according to the module installed and how the switch will be used.

Mode of 6850E Daughter Module

Stacking

Uplink

Capability

CX4 -Allows stacking with otoher 6850E.

SFP+ - Allows stacking with other OS6850E.

CX4 - Not Supported.

SFP+ - Acts as uplink ports.

The following example shows how to change the mode to stacking using the interfaces mode

command.

-> interfaces 1/25 mode stacking

WED JUL 01 18:08:29 : HSM-CHASSIS (101) info message:

+++ Ni 1 Port 25,26 are set to stackable for next boot:OK

-> reload working no rollback-timeout

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-3

OmniSwitch 6850E Series Stack Overview Managing OmniSwitch 6850E Series Stacks

OmniSwitch 6850E Series Stack Overview

Users can configure up to eight switches, in any combination of chassis types, into a single virtual chassis known as a stack. With stacks, switching capacity can be easily expanded simply by adding additional switches to the stack. For example, a user can start with a stack composed of two switches and add up to six additional switches to that stack as network demands increase over time.

Note. Switches should be added one at a time in a stack.

Stacks also provide enhanced resiliency and redundancy features. If a switch in a stack goes down or is taken offline, the other elements in the stack will continue to operate without disruption. In addition, when a switch auto-synchronizes at boot-up, or if the user manually synchronize the switches (see

“Synchronizing Switches in a Stack” on page 6-37

for more information), operating software and configuration parameters are backed up on all switches in the stack. As a result, the original operating software and configuration parameters can be easily recovered if corrupted or otherwise lost.

Note on Terminology. The terms stack and virtual chassis are interchangeable referring to switches in a stacked configuration. The terms module, switch, slot, and element are used to refer to individual switches within a stacked configuration. The terms Chassis Management Module (CMM) and management module refer to those switches operating in a stack either in the primary or secondary management roles. Switches operating in an idle role are essentially acting as network interface modules and therefore may be referred to as Network Interfaces (NIs).

Roles Within the Stack

In order to operate as a virtual chassis, switches within a stack are assigned specific roles. These roles include primary and secondary management roles, idle status, and pass-through. For detailed descriptions of each of these roles, including their practical functions within the virtual chassis, refer to the sections below.

Primary and Secondary Management Modules

When switches operate in a stack, one switch in the stack always assumes the primary management role.

This primary element is responsible for functions, such as software and configuration management, webbased management (i.e., WebView), SNMP management, switch diagnostics, and software rollback.

One additional switch in the stack operates in a secondary management role. This switch serves as a backup, and is always ready to assume the primary management role in the stack if the switch with the primary role fails or is taken offline for any reason.

Since the secondary module quickly and automatically assumes management responsibilities, switches operating in idle mode elsewhere in the stack continue to pass traffic without disruption. This redundancy provides effective safeguards for mission-critical network traffic and is one of the stack’s most important failover features. Diagrams showing the management module failover sequence for stacks of three or more switches and stacks of two switches are provided on pages

6-5

and 6-6

, respectively.

page 6-4 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Roles Within the Stack

Important Note. For management module redundancy to work effectively, the software on all switches

operating in the stack must be synchronized at all times. Refer to “Synchronizing Switches in a Stack” on page 6-37

for more information.

Primary

Secondary

Idle

Idle

1

A stack of four switches is operating normally. The stack consists of a primary module, secondary module, and two elements operating in idle status. (The software on all elements in the stack is synchronized.)

Offline

Secondary

!

Idle

Idle

2

The primary management module in the stack fails or is taken offline (e.g., powered off or rebooted by the user).

Offline

Primary

Secondary

Idle

3

The switch operating as the secondary management module immediately takes over the primary role. Meanwhile, the adjacent switch—previously operating in idle status—now assumes the secondary management role.

Idle

Primary

Secondary

Idle

4

If the switch that failed or was taken offline comes back online, it will assume an idle role in the stack. In other words, it will act essentially as an NI module in the virtual chassis, passing traffic via its Ethernet.

Redundant Management Module Failover (Three or More Switches)

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-5

Roles Within the Stack Managing OmniSwitch 6850E Series Stacks

Primary

Secondary

1

A stack of two switches is operating normally. The stack consists of a primary module and a secondary module. (The software on both elements in the stack is synchronized.)

Offline

Secondary

!

2

The primary management module fails or is taken offline (e.g., powered off or rebooted by the user).

Offline

Primary

3

The switch operating as the secondary management module immediately takes over the primary role. It is at this point essentially operating as a stand-alone switch.

Secondary

Primary

4

If the switch that previously failed or was taken offline comes back online, it will assume the secondary role in the stack.

Redundant Management Module Failover (Two Switches) page 6-6 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Roles Within the Stack

Primary Management Module Selection

For a stack of switches to operate as a virtual chassis, there must be a mechanism for dynamically selecting the switch within the stack that will assume the primary management role. OmniSwitches use three different methods for selecting the primary switch. These methods are:

Chassis MAC address

Saved slot number

Chassis uptime

Note. Information on secondary management module selection is provided on

page 6-10 . Information on

dynamic assignment of idle module roles is provided on page 6-12

.

Using the Chassis MAC Address

By default, the primary management role will be given to the switch with the lowest chassis MAC address. However, for this to occur, all switches in the stack must be booted within 15 seconds of each other. In addition, switches in the stack must have no preconfigured slot information. Because of these two conditions, the MAC address method for selecting the primary module usually occurs with new “out of the box” switches, or switches from which any preconfigured slot information has been cleared.

For more information on using the lowest MAC address to determine the primary switch in a stack, refer to the diagram below:

1

A stack of four switches is booted. All switches are powered on within 15 seconds of each other. In addition, there is no preconfigured slot information on any of the switches.

00:d0:95:b2:3c:8e

00:d0:95:b2:2a:ab

00:d0:95:b2:1c:ff

00:d0:95:b2:5b:8d

2

When the stack is booted, system software detects the lowest

MAC address. In this stacked configuration, the lowest

MAC address is 00:d0:95:b2:1c:ff.

00:d0:95:b2:3c:8e

00:d0:95:b2:2a:ab

Primary Module

00:d0:95:b2:5b:8d

3

The system software immediately assigns the corresponding switch the primary management role. When the switch is assigned as primary, it is also dynamically assigned the lowest slot number in the stack—i.e., slot 1. This slot number information is saved to the boot.slot.cfg file, located in the switch’s /flash file directory.

Primary Management Module Selection Using the Lowest Chassis MAC Address

Note. During the boot process, all other switches in the stack are also dynamically assigned unique slot numbers. As with the primary switch, these slot numbers are saved to the boot.slot.cfg file, located in the

/flash file directory of each switch. For more information on dynamic slot number assignment, refer to

“Slot Numbering” on page 6-20

.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-7

Roles Within the Stack Managing OmniSwitch 6850E Series Stacks

Using Saved Slot Information

The saved slot number is the slot number the switch will assume following a reboot. This information is stored in a switch’s boot.slot.cfg file; the switch reads its slot number assignment from this file at bootup and assumes the specified slot number within the stack.

If switches in a stacked configuration have no preconfigured slot assignments, the slot number for each switch is dynamically assigned by the system software. Slot numbers can also be manually assigned by the user. For more information on manually assigning slot numbers, refer to

“Manual Slot Number Assignment” on page 6-23 .

When a stack with preconfigured slot information is booted, it is not the lowest MAC address that determines the primary management module. Instead, the slot information stored in each switch’s boot.slot.cfg is read by the system software and used in determining the primary. The switch with the lowest saved slot number becomes the primary management module.

Note. Although, for ease-of-management purposes, it is recommended that slot numbers are assigned beginning with slot number 1, it is not a requirement. In other words, a stack of four switches can have slot assignments 3, 4, 5, and 6. However, it is important that each element in a stack is assigned a unique slot number. Do not assign duplicate slot numbers to elements in a stack. Otherwise, one or more switches will be forced into pass-through mode. For more information on pass-through mode, refer to

page 6-13

.

For more information on using saved slot information to determine the primary switch in a stack, refer to the diagram below:

Saved Slot 6

Saved Slot 5

Saved Slot 4

Saved Slot 3

1

Four switches are stacked; all switches are connected via stacking cables. The user configures each switch to have a unique saved slot number. When each saved slot number is configured, the information is automatically written to the boot.slot.cfg file located in the /flash directory of each switch.

Reload

2

The user reloads all the elements in the stack either by issuing the reload all command or by physically powering off and then powering on all switches.

page 6-8

Assumes Slot 6

Assumes Slot 5

Assumes Slot 4

Assumes Slot 3

3

Instead of assigning the primary management module based on the lowest MAC address, the system software reads the slot information from each switch’s boot.slot.cfg file during the boot process. The switches in the stack come up using their assigned slot numbers.

Slot 6

Slot 5

Slot 4

Primary: Slot 3

4

The switch with the lowest assigned slot number automatically assumes the primary management role. In this case, the switch assigned slot 3 has the lowest slot number in the stack and becomes the primary management module.

Primary Management Module Selection Using Saved Slot Information

OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Roles Within the Stack

Using Switch Uptime

A user can override both the MAC address and saved slot methods for determining a stack’s primary management module. This is done by controlling the uptime of switches in the stack. If all elements of a stack are powered off, the user can force a particular switch to become primary by powering on that switch and waiting a minimum of 15 seconds before powering on any other switches. This can be useful if the user wants a switch placed in a specific location, e.g., the top-most switch in a stack, to become the primary.

As with the lowest MAC address method, the primary management module is dynamically assigned slot number 1 when the stack is booted.

For more information on using saved slot information to determine the primary switch in a stack, refer to the diagram below:

Off

Off

Off

Powered On

1

Four switches are stacked and connected via stacking cables. All switches are currently powered off. The user powers on a single switch in the stack. In this case, the bottom-most switch is powered on.

Off

Off

Off

Primary

(Saved Slot 8)

Powered On

Powered On

Powered On

Primary

(Saved Slot 8)

Saved Slot 3

Saved Slot 1

Saved Slot 2

Primary

(Saved Slot 8)

2

3

The user allows a minimum of 15 seconds to pass. Because no other switches have joined the stack, the switch that was powered on considers itself a stand-alone. The switch assumes a primary role by default—even if there is a high saved slot number in its boot.slot.cfg file (e.g., 8).

The user now powers on the remaining switches in the stack in short succession.

4

In this example, when the remaining switches come online, each has a lower saved slot value than the switch powered on at step 1. However, the switch powered on at step 1—with its slot value of 8—retains its primary management role. The joining switches are essentially ineligible for primary status because they are considered “late arrivals.”

For the primary switch to forfeit its role to the switch with the lowest assigned slot number (in this case, slot number 1), the stack must be rebooted by the user either by issuing the reload all command or by powering off and powering on all switches in close succession.

Primary Management Module Selection Using Switch Uptime

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-9

Roles Within the Stack Managing OmniSwitch 6850E Series Stacks

Secondary Management Module Selection

In order to provide effective management module redundancy, all stacked configurations dynamically assign a backup, or secondary, management module during the boot process. Stacks use two different methods for selecting the secondary switch. These methods are:

Stacking connection to the primary switch

Saved slot number

Using the Stacking Connection to the Primary Switch

By default, the switch that is connected to the primary switch’s stacking port A is automatically assigned the secondary management role. This applies to stacks on which there is no preassigned slot information— i.e., there is no boot.slot.cfg file present in any switch.

For more information on using the stacking connection to the primary switch to determine the secondary management module, refer to the diagram below:

A B

1

Four switches are stacked and connected via stacking cables, as shown. All switches are currently powered off. None of the switches have preassigned slot numbers—i.e., there are no boot.slot.cfg files present. The user powers on all switches in the stack in close succession and the stack begins the boot process.

A B

00:d0:95:b2:3c:8e

00:d0:95:b2:2a:ab

00:d0:95:b2:1c:ff

(Primary - Slot 1)

00:d0:95:b2:5b:8d

2

When the elements in the stack come online, the switch with the lowest MAC address is given the primary management role and is dynamically assigned slot number 1.

A B

Idle

Idle

Primary

Secondary - Slot 2

3

By default, the switch connected to the primary’s stacking port A is automatically assigned the secondary management role.

The secondary switch is dynamically assigned slot number 2.

Secondary Management Module Selection Using the Stacking Connection to the Primary Switch

Note. For information on dynamic slot numbering for idle elements within the stack, refer to

“Idle Module

Role” on page 6-12 and

“Slot Numbering” on page 6-20 .

page 6-10 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Roles Within the Stack

Using Saved Slot Information

If a stack with preassigned slot information for each switch is booted, the switch with the second lowest slot value is assigned the secondary management role. For example, if a stack of four switches is booted and the preassigned slot values for each switch are 1, 2, 3, and 4, the switch with the slot value of 2 is assigned the secondary role. Meanwhile, the switch with the slot value of 1 is assigned the primary management role (see

page 6-8 ).

For more information on using saved slot information to determine the secondary management module in a stack, refer to the diagram below:

Saved Slot 1

Saved Slot 3

Saved Slot 4

Saved Slot 2

1

Four switches are stacked; all switches are connected via stacking cables. The user configures each switch to have a unique saved slot number, as shown. When the saved slot number is configured, the information is automatically written to the boot.slot.cfg file located in the /flash directory of each switch.

Reload

2

The user reloads all the elements in the stack either by issuing the reload all command or by physically powering off and then powering on all switches.

Assumes Slot 1

Assumes Slot 3

Assumes Slot 4

Assumes Slot 2

3

The system software reads the slot information from each switch’s boot.slot.cfg file during the boot process. The switches in the stack come up using their assigned slot numbers.

Primary - Slot 1

Slot 3

Slot 4

Secondary - Slot 2

4

The switch with the lowest assigned slot number automatically assumes the primary management role. The switch with the second lowest assigned slot number becomes the secondary management role, regardless of whether it is attached to stacking port A of the primary switch. In this case, the switch assigned slot 2 has the second-lowest slot number in the stack and becomes the secondary management module.

Secondary Management Module Selection Using Saved Slot Information

Reminder. Each element in a stack should always be assigned a unique slot number. Do not assign duplicate slot numbers to elements in a stack. Otherwise, one or more switches will be forced into

pass-through mode. For more information on pass-through mode, refer to page 6-13 .

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-11

Roles Within the Stack Managing OmniSwitch 6850E Series Stacks

Idle Module Role

Switches that are not assigned either the primary or secondary role in a stack are, by default, assigned the role of idle modules. These idle modules operate similarly to Network Interface (NI) modules in a chassisbased switch.

In the event of a management module failure within the stack, the idle module with the next lowest slot number in the stack will automatically assume the secondary management role. In other words, if the primary module in a stack goes down for any reason and the secondary takes over the primary management role, the switch must now assign a new secondary module. The idle element with the next lowest slot number assumes this new responsibility until the situation is corrected and all elements in the stack are reloaded.

Note. Primary and secondary management modules also send and receive traffic on their Ethernet ports.

The primary management module is like an NI module with the added task of overall stack management; the secondary management module is like an NI with the added responsibility of backing up the primary module in the event of a primary module failure. In other words, all modules in the virtual chassis can send and receive user data, regardless of their roles.

For more information on dynamic assignment of idle modules in a stack, refer to the diagram below:

1

Four switches are stacked; all switches are connected via stacking cables. The stack is booted.

2

The primary and secondary management modules are dynamically

assigned using any of the methods outlined on pages 6-7

through

6-11 .

Primary

Secondary

Idle

Idle

Primary

Secondary

3

The system software automatically assigns the remaining elements in the stack the idle module role. These modules act as Network

Interface (NI) modules, sending and receiving 10/100/1000

Ethernet traffic on their ports.

In the event of a primary-to-secondary failover, the idle module with the next-lowest slot number in the stack will assume the secondary—or backup—management role.

Secondary Management Module Selection Using Saved Slot Information page 6-12 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Roles Within the Stack

Pass-Through Mode

The pass-through mode is a state in which a switch has attempted to join a stack but has been denied primary, secondary, and idle status. When a switch is in the pass-through mode, its Ethernet are brought down (i.e, they cannot pass traffic). Its stacking cable connections remain fully functional and can pass traffic through to other switches in the stack. In this way, the pass-through mode provides a mechanism to prevent the stack ring from being broken. However, note that when a switch comes up in pass-through mode, it should not be left unresolved. Pass-through mode is essentially an error state that should be corrected immediately by the user.

Note. When a switch is in pass-through mode, its information will not display in hardware monitoring commands such as show chassis, show ni, show module, etc.

Conditions that can trigger a switch to enter pass-through mode include:

Duplicate slot numbers or incorrect stacking modes have been assigned within the stack

The user has manually forced the switch into pass-through mode using the stack clear slot command

Note. If a switch is forced into pass-through mode, the rest of the stack will not be disrupted. Any elements in the stack not operating in pass-through mode continue to operate normally.

The most common reason for one or more switches to enter pass-through is duplicate slot number assignments within the stack. So, in order to avoid pass-through mode, it is useful to keep track of the current saved slot numbers on all elements in the stack. Slot number assignments are stored in the boot.slot.cfg file in the /flash directory of each switch.

If the stack is booted and the same slot number is discovered on two or more switches, the switch with the lowest MAC address is allowed to come up and operate normally. Meanwhile, switches with the duplicate slot number and a higher MAC address come up in pass-through mode. To check the current slot number stored in each switch’s boot.slot.cfg file, use the show stack topology command. For example:

-> show stack topology

Link A Link A Link B Link B

NI Role State Saved Link A Remote Remote Link B Remote Remote

Slot State NI Port State NI Port

----+-----------+--------+------+-------+-------+-------+-------+-------+-------

1 PRIMARY RUNNING 1 UP 3 StackA UP 2 StackA

2 SECONDARY RUNNING 2 UP 1 StackB UP 3 StackB

3 IDLE RUNNING 2 UP 1 StackA UP 2 StackB

In this example, note that both slots 2 and 3 have a saved slot value of 2. If this stack is rebooted, a duplicate slot error will occur and the switch with the lower MAC address will be given the secondary management role. The slot with the higher MAC address will be forced into the pass-through mode.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-13

Roles Within the Stack Managing OmniSwitch 6850E Series Stacks

To avoid a pass-through condition following a reboot, make sure that all saved slot values for the stack are unique. Use the stack set slot command. For example, change the saved slot value for the idle switch in slot 3 from 2 to 3:

-> stack set slot 3 saved-slot 2

Use the show stack topology command to verify the change:

-> show stack topology

Link A Link A Link B Link B

NI Role State Saved Link A Remote Remote Link B Remote Remote

Slot State NI Port State NI Port

----+-----------+--------+------+-------+-------+-------+-------+-------+-------

1 PRIMARY RUNNING 1 UP 3 StackA UP 2 StackA

2 SECONDARY RUNNING 2 UP 1 StackB UP 3 StackB

3 IDLE RUNNING 3 UP 1 StackA UP 2 StackB

Recovering from Pass-Through Mode (Duplicate Slot Numbers)

The first step in recovering from pass-through is to determine which modules are currently operating in pass-through, as well as the reason for the pass-through state. To view this information, use the show stack topology command. For example:

-> show stack topology

Link A Link A Link B Link B

NI Role State Saved Link A Remote Remote Link B Remote Remote

Slot State NI Port State NI Port

----+-----------+--------+------+-------+-------+-------+-------+-------+-------

1 PRIMARY RUNNING 1 UP 1001 StackA UP 2 StackA

2 SECONDARY RUNNING 2 UP 1 StackB UP 1001 StackB

1001 PASS-THRU DUP-SLOT 2 UP 1 StackA UP 2 StackB

Switches operating in pass-through mode are given distinct slot numbers. These slot numbers are not related to their position in the stack. Instead, they are assigned the prefix “100,” followed by the numerical order in which they were forced into pass-through (1001–1008).

Note. For pass-through elements 1001 through 1008, the slot indicator LED on the chassis front panel blinks 1 through 8, respectively. For example, if a module enters pass-through and has the slot number

1004, the LED for the module blinks the number 4. For more information on the slot indicator LED, refer to “Status LEDs” on page 2-53 .

In the example above, the switch with the NI (i.e., slot) number 1001 is operating in pass-through. Note that the role assignment is PASS-THRU; also, the state displays DUP-SLOT, or duplicate slot number.

This can be further verified by looking down the saved slot column in the table. Note that slot 2, operating in the secondary management role, has a saved slot value of 2. Slot 1001, operating in pass-through, also has a saved slot value of 2. page 6-14 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Roles Within the Stack

To resolve this pass-through condition, simply assign slot 1001 a new saved slot value and reboot the module. This can be done in either of two ways:

Use the stack set slot command to assign the new value, then use the reload pass-through command to reboot the module:

-> stack set slot 1001 saved-slot 3

-> reload pass-through 1001

Use the stack set slot command to assign the new slot value and, using the optional reload syntax in the command line, reboot the module:

-> stack set slot 1001 saved-slot 3 reload

When the module comes up, it assumes the new, unique slot position—in this case, slot 3—and, because it now has the highest slot number in the stack, it assumes an idle role (leaving the primary and secondary roles to slots 1 and 2, respectively). There are now no duplicate numbers in the stack and all elements are operating normally:

-> show stack topology

Link A Link A Link B Link B

NI Role State Saved Link A Remote Remote Link B Remote Remote

Slot State NI Port State NI Port

----+-----------+--------+------+-------+-------+-------+-------+-------+-------

1 PRIMARY RUNNING 1 UP 3 StackA UP 2 StackA

2 SECONDARY RUNNING 2 UP 1 StackB UP 3 StackB

3 IDLE RUNNING 3 UP 1 StackA UP 2 StackB

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-15

Roles Within the Stack Managing OmniSwitch 6850E Series Stacks

In some pass-through conditions (for example, larger stacks where multiple switches are in pass-through mode), it might be desirable to correct any duplicate saved slot assignments and then reboot the entire stack. The recovery from pass-through can be accomplished with fewer steps than reassigning slot numbers and rebooting modules on a slot-by-slot basis. However, be sure that there is no mission-critical traffic being passed on the non-pass-though modules; traffic will be interrupted on these modules during the reboot.

The following example shows a large stack with multiple elements operating in pass-through mode:

-> show stack topology

Link A Link A Link B Link B

NI Role State Saved Link A Remote Remote Link B Remote Remote

Slot State NI Port State NI Port

----+-----------+--------+------+-------+-------+-------+-------+-------+-------

4 IDLE RUNNING 4 UP 5 StackB UP 3 StackA

5 IDLE RUNNING 5 UP 1001 StackB UP 4 StackA

1001 PASS-THRU DUP-SLOT 2 UP 2 StackB UP 5 StackA

2 SECONDARY RUNNING 2 UP 1003 StackB UP 1001 StackA

1003 PASS-THRU DUP-SLOT 2 UP 1002 StackB UP 2 StackA

1002 PASS-THRU DUP-SLOT 2 UP 1 StackB UP 1003 StackA

1 PRIMARY RUNNING 1 UP 3 StackB UP 1002 StackA

3 IDLE RUNNING 3 UP 4 StackB UP 1 StackA

This disordered stack topology, with its three modules operating in pass-through mode, can be corrected by entering the following commands:

-> stack set slot 4 saved-slot 1

-> stack set slot 5 saved-slot 2

-> stack set slot 1001 saved-slot 3

-> stack set slot 2 saved-slot 4

-> stack set slot 1003 saved-slot 5

-> stack set slot 1002 saved-slot 6

-> stack set slot 1 saved-slot 7

-> stack set slot 3 saved-slot 8

-> reload all

When all elements in the stack come up following the reboot, there are no longer any duplicate slot numbers in the stack. In addition, the stack topology is more orderly and, as a result, easier to manage:

-> show stack topology

Link A Link A Link B Link B

NI Role State Saved Link A Remote Remote Link B Remote Remote

Slot State NI Port State NI Port

----+-----------+--------+------+-------+-------+-------+-------+-------+-------

1 PRIMARY RUNNING 1 UP 2 StackB UP 8 StackA

2 SECONDARY RUNNING 2 UP 3 StackB UP 1 StackA

3 IDLE RUNNING 3 UP 4 StackB UP 2 StackA

4 IDLE RUNNING 4 UP 5 StackB UP 3 StackA

5 IDLE RUNNING 5 UP 6 StackB UP 4 StackA

6 IDLE RUNNING 6 UP 7 StackB UP 5 StackA

7 IDLE RUNNING 7 UP 8 StackB UP 6 StackA

8 IDLE RUNNING 8 UP 1 StackB UP 7 StackA page 6-16 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Stack Cabling

Stack Cabling

Switches in a stack are connected to each other by stacking cables. The stacking cables come in various

lenghts and types as as listed on page 6-3 and provide high-speed, dual-redundant links between switches

in a stack.

Stacking cables for can be connected in any pattern. In other words, the cable connected to stacking port A of one switch can be connected to either stacking port A or stacking port B of the adjacent switch.

However, it is strongly recommended that the cabling pattern remains consistent across the stack. In addition, for a stack to have effective redundancy, a redundant stacking cable must be installed between the upper-most and bottom-most switch at all times. This provides effective failover in the event of a stacking link or module failure within the stack.

The diagram below shows two recommended stacking cable patterns. For detailed information on assembling a stack and connecting the cables, refer to Chapter 2, “OmniSwitch 6850 Series Chassis and Hardware Components.”

Note. When planning the stack cabling configuration, keep in mind that the switch connected to stacking port A of the primary switch will be assigned the secondary management role by default.

A B

A stack of eight switches in a crossed (stacking port

A to stacking port B) configuration. Note that a redundant stacking cable connection exists between the top and bottom switches. This connection is required for effective redundancy across the stack.

A B

A stack of eight switches in a straight (stacking port A to stacking port A; stacking port B to stacking port B) configuration. Note that a redundant stacking cable connection exists between the top and bottom switches. Again, this connection is required for effective redundancy across the stack.

Examples of Stacking Cable Patterns (Chassis Rear Panels Shown)

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-17

Stack Cabling Managing OmniSwitch 6850E Series Stacks

Redundant Stacking Cable Connection

OmniSwitches allow redundant stacking cable connections between the top-most and bottom-most switches in a stack.

Important. For a stacked configuration to have effective redundancy, a redundant stacking cable must be installed between the upper-most and bottom-most switch in the chassis at all times.

The figure below shows how the redundant connection between the top and bottom switches in the stack ensures that data will continue to flow throughout the stack, even in the event of a connection failure at one of the stacking cables.

Stacking Cables Chassis Front

Slot 1

Slot 2

Slot 3

Slot 4

1

Data enters slot 1 via a 10/100/1000 Ethernet port. The data is passed to slot 2 over the stacking cable connection, then exits slot 2 via one of its 10/100/1000 Ethernet.

Slot 1

Slot 2

Slot 3

Slot 4

2

The stacking connection between slots 1 and 2 goes down unexpectedly. Data can no longer travel directly between slot 1 and 2.

However, because there is a redundant connection (the cable between slot 1 and slot 4), data is immediately passed to slot 4, then quickly traverses slot 3 and exits slot 2 to its destination.

Stacking Cable Redundancy: Recovery Following a Stacking Link Failure page 6-18 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Stack Cabling

Redundant stacking cables provide a form of dual redundancy. As shown in the figure above, the redundant cable allows traffic to flow in the event of a stacking link failure. The redundant cable also provides failover if a switch goes down within the stack. Traffic continues to flow between the modules that remain operational, as shown in the diagram below:

Stacking Cables Chassis Front

Slot 1

Slot 2

Slot 3

Slot 4

1

Data enters slot 1 through a 10/100/1000 Ethernet port.

The data traverses slot 2 via the stacking cables and exits slot 3 through one of its 10/100/1000 Ethernet.

Slot 1

Slot 2

Slot 3

Slot 4

2

The slot 2 switch goes down unexpectedly. Data can no longer move through slot 2.

However, because there is a redundant connection (the cable between slot 1 and slot 4), data immediately traverses slot 4 and then exits slot 3 to its destination.

Stacking Cable Redundancy: Recovery Following a Switch Failure within the Stack

Checking Redundant Stacking Cable Status

To check whether a redundant stacking cable connection exists between the top-most and bottom-most switches in the stack, use the show stack status command. For example:

-> show stack status

Redundant cable status : present

Tokens used : 12

Tokens available : 20

In this example, a redundant stacking cable connection is present between the top-most and bottom-most switches in the stack.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-19

Slot Numbering Managing OmniSwitch 6850E Series Stacks

Slot Numbering

For a stack of switches to operate as a virtual chassis, each module in the stack must be assigned a unique slot number. To view the current slot assignments for a stack, use the show ni or show module commands. The slot number is also displayed on the front panel of each switch by the LED located on the left side of the chassis (refer to “Status LEDs” on page 2-53 for more information).

There are two ways stacking modules are assigned slot numbers:

Dynamic slot number assignment by the system software

Manual slot number assignment by the user page 6-20 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Slot Numbering

Dynamic Slot Number Assignment

Dynamic slot number assignment occurs when there are no boot.slot.cfg files present in the switches’

/flash directories. This is the case for new, “out of the box,” switches that have not been previously booted.

When a brand new stack (or stack with no boot.slot.cfg files) is booted, the system software automatically detects the module with the lowest MAC address. This module is assigned the primary management role (see

page 6-4

) and, by default, is given the slot number 1. The module connected to the primary’s stacking port A is automatically assigned the secondary management role and given the slot number 2.

As the other modules in the stack become operational, they are assigned idle roles and are automatically assigned unique slot numbers (3–8, depending on the number of switches in the stack). The slot numbering for idle modules is determined by each module’s physical location in the stack. Refer to the diagrams below for more information on dynamic slot numbering.

Note. As the slot numbers are dynamically assigned, boot.slot.cfg files are auto-generated in the /flash directory of each switch. When modules are subsequently booted, each switch reads its slot number assignment from this file and comes up accordingly.

Slot 6 - Idle

Slot 7 - Idle

Slot 8 - Idle

Slot 1 - Primary

Slot 2 - Secondary

Slot 3 - Idle

Slot 4 - Idle

Slot 5 - Idle

In this example, the fourth switch from the top is elected the primary management module for the stack. (It can be assumed that this switch has the lowest MAC address in the stack.) This switch is automatically assigned slot number 1.

The switch immediately below is connected to the primary switch’s stacking port A and, as a result, is assigned the secondary management role and given slot number 2.

The system software allows the switch immediately below slot 2 to have the next slot number preference.

It is assigned an idle role and given the slot number 3.

The switch immediately below slot 3 is given the slot number 4, and so on. When the bottom of the stack is reached, the slot numbering sequence resumes at the top of the stack, as shown. This helps ensure a more ordered and manageable stack topology.

Dynamic Slot Numbering Example 1

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-21

Slot Numbering Managing OmniSwitch 6850E Series Stacks

If the switch with the lowest MAC address happens to be the bottom-most module in the stack, slot numbering will not resume from the top of the stack. Instead, the system software will select the secondary module using the standard method (i.e., the switch connected to the primary’s stacking port A), then continue to number the stack from the bottom up. This intuitive slot assignment provides the cleanest and most manageable stack topology. Refer to the diagram below for more information:

Slot 8 - Idle

Slot 7 - Idle

Slot 6 - Idle

Slot 5 - Idle

Slot 4 - Idle

Slot 3 - Idle

Slot 2 - Secondary

Slot 1 - Primary

In this example, the bottom switch is elected the primary management module for the stack.

(It can be assumed that this switch has the lowest MAC address in the stack.) This switch is automatically assigned slot number 1.

The switch immediately above is connected to the primary switch’s stacking port A and, as a result, is assigned the secondary management role and given slot number 2.

The system software then sequentially assigns slot numbers up the stack. In other words, the switch immediately above slot 2 is assigned the slot number 3; the switch immediately above slot 3 is assigned the slot number 4, and so on. This default procedure ensures the most ordered and manageable stack topology out of the box.

Dynamic Slot Numbering Example 2 page 6-22 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Slot Numbering

Manual Slot Number Assignment

To manually assign slot numbers to one or more modules in a stack, use the stack set slot command. This command writes slot information to the boot.slot.cfg file located in a switch’s /flash directory. It is this saved slot information that the switch will assume following a reboot.

Manually assigning slot numbers can be useful in reordering existing slot numbers in order to create a sequential numbering scheme from the top of the stack to the bottom (or vice-versa). Refer to the following example:

Slot 6 - Idle

Slot 7 - Idle

Slot 8 - Idle

Slot 1 - Primary

Slot 2 - Secondary

Slot 3 - Idle

Slot 4 - Idle

Slot 5 - Idle

This example, taken from

page 6-21

, shows a stack in which the primary and secondary switches are physically positioned in the middle of the stack. Although the stack will operate normally with this primary and secondary module positioning, it may be preferable for management purposes to have the primary and secondary switches at either the top or the bottom of the stack. For this example, the primary and secondary roles will be assigned to the top of the stack. This is accomplished by entering the following commands:

-> stack set slot 6 saved-slot 1

-> stack set slot 7 saved-slot 2

-> stack set slot 8 saved-slot 3

-> stack set slot 1 saved-slot 4

-> stack set slot 2 saved-slot 5

-> stack set slot 3 saved-slot 6

-> stack set slot 4 saved-slot 7

-> stack set slot 5 saved-slot 8

-> reload all

Because slot 6 is the top-most switch in the stack, it is reassigned the slot 1 (i.e., primary) position; because slot 7 is located immediately below slot 6, it is reassigned the slot 2 (i.e., secondary) position, etc.

Note that the modules were not reloaded one-by-one, even though the stack set slot command provides optional syntax for doing so. Instead, new slot number information is first saved to each boot.slot.cfg file across the stack. The reboot is saved for last in order to avoid duplicate slot numbers within the stack, which would cause unwanted pass-though mode conditions (see

page 6-13

).

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-23

Slot Numbering Managing OmniSwitch 6850E Series Stacks

When the stack comes up following the reboot, the manually-configured slot numbers display as follows:

Slot 1 - Primary

Slot 2 - Secondary

Slot 3 - Idle

Slot 4 - Idle

Slot 5 - Idle

Slot 6 - Idle

Slot 7 - Idle

Slot 8 - Idle

The stack set slot command can also be used to manually correct duplicate saved slot assignments within

the stack topology. Refer to pages 6-13

through

6-15 for detailed information.

Reverting to the Dynamic Slot Numbering Model

To clear the boot.slot.cfg files from the stack’s /flash directories, use the stack clear slot command on all modules and then reboot the stack. For example:

-> stack clear slot 1

-> stack clear slot 2

-> stack clear slot 3

-> stack clear slot 4

-> stack clear slot 5

-> stack clear slot 6

-> stack clear slot 7

-> stack clear slot 8

-> reload all

The commands shown above clear the saved slot information from all modules in an eight-module stacked configuration and then reboot the stack. Because the system software no longer has preassigned slot information to read during the boot process, the stack uses the dynamic slot number assignment method described on

page 6-21 .

page 6-24 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Hot-Swapping Modules In a Stack

Hot-Swapping Modules In a Stack

Modules within a virtual chassis are hot-swappable. NI modules are essentially those modules operating in the stack in idle mode. These modules can be removed from, or added to, an existing stack without disrupting other modules in the stack.

Removing Switches from an Existing Stack

When removing switches from an existing stack, observe the following important guidelines:

Do not attempt to hot-swap modules operating in primary or secondary management roles

Be sure the stacking cables and stacking cable redundancy are not disrupted

Hot-swapping is intended for switches in idle and, if applicable, pass-through status only. Removing primary or secondary management modules from a stack will trigger a failover sequence, i.e., one or more additional modules within the stack must reload in order to reassign the management roles. Whenever possible, avoid removing a switch that is operating as a primary or secondary management module.

Also, removing a switch from a stacked configuration can disrupt stack cabling at the rear of the stack.

When removing a module, be sure that stacking link integrity, including important stacking cable redundancy, is maintained between all remaining modules. For more information on stacking cable connec-

tions, refer to page 6-17 .

Inserting Switches Into an Existing Stack

When inserting switches into an existing stack, observe the following important guidelines:

Avoid duplicate saved slot numbers

Never attempt to operate more than eight switches in a single stack

Make sure all switches are running the same software version.

To avoid duplicate slot numbers, simply make sure that any modules being added to an existing stack have been cleared of preassigned slot information. In other words, verify that there is no boot.slot.cfg file present in the /flash directory of any switch being added. When the switch is connected to the existing stack and booted, the system software automatically assigns it a unique slot number. No duplicate slot errors occur.

Note. If it is preferable to add a switch with an existing boot.slot.cfg file to a stack, be sure that the saved slot number of the incoming switch is not already assigned to a switch operating in the stack.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-25

Hot-Swapping Modules In a Stack Managing OmniSwitch 6850E Series Stacks

Merging Stacks

Merging stacks involves connecting two or more operational stacks and attempting to reboot them as a single virtual chassis. In most cases, errors will result. To merge stacks without causing errors, select one stack that is to remain up and running and then add modules from the other stack(s) by following the steps below:

1

Make sure all switches are running the same software version.

2 Clear the saved slot information from all incoming modules. This will ensure that they are each assigned unique slot numbers when they join the stack.

3

After clearing the saved slot information, power off all incoming modules.

4 Connect the stacking cables for all incoming modules to the existing, operational stack as required. Be

sure to provide stacking cable redundancy. For information on stack cabling, refer to page 6-17 .

5

Power on all incoming modules.

Note. No more than eight switches can operate in a single stacked configuration at any time.

page 6-26 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Reloading Switches

Reloading Switches

Reloading is essentially a soft boot of a switch. Users can reload stacked modules operating in any role— i.e., primary, secondary, idle, and pass-through. Refer to the sections below for more information.

Reloading the Primary Management Module

If the switch with the primary management role is reloaded, the switch with the secondary role automatically takes over primary management functions. In other words, the switch with the secondary role assumes the primary role as soon as the reload is initiated.

Meanwhile, the idle switch with the next lowest slot number automatically assumes the secondary role.

When the reloaded switch (the former primary module) comes back up, it assumes an idle role within the stack.

To reload the primary management module, use the reload command. The optional syntax primary can be used in the command line, but is not required. For example:

-> reload primary

Note. A primary management module reload can also be scheduled for a later time or date. For information on scheduling a primary module reload, as well as additional command details, refer to the

OmniSwitch CLI Reference Guide.

Primary - Slot 1

Secondary - Slot 2

Idle - Slot 3

Idle - Slot 4

1

In this stack of four switches, the slot 1 switch is the primary management module. The slot 2 switch is the secondary. Slots 3 and 4 are operating in idle roles.

-> reload primary

2

The user reloads the stack’s primary management module by issuing the reload primary command. Any data flow on the primary switch’s Ethernet is interrupted.

Booting...

Primary - Slot 2

Secondary - Slot 3

Idle - Slot 4

3

The secondary switch automatically takes over the primary role.

The idle switch with the next-lowest slot number—in this case, slot 3—automatically becomes the secondary management module.

The slot 4 switch remains unaffected. In addition, Ethernet traffic on slots 2, 3, and 4 remains unaffected.

Idle - Slot 1

Primary - Slot 2

Secondary - Slot 3

Idle - Slot 4

4

When the rebooted switch comes back up, it assumes an idle role within the stack.

Reloading the Primary Management Module In a Stack of Three or More

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-27

Reloading Switches Managing OmniSwitch 6850E Series Stacks

If there are only two switches in the stack, the switch that was reloaded (the former primary) assumes the secondary role when it comes back up.

Primary - Slot 1

Secondary - Slot 2

1

In this stack of two switches, the slot 1 switch is the primary management module. The slot 2 switch is the secondary.

-> reload primary

Booting...

Primary - Slot 2

2

The user reloads the stack’s primary management module by issuing the reload primary command. Any data flow on the primary switch’s Ethernet is interrupted.

3

The secondary switch automatically takes over the primary role.

Ethernet traffic on slot 2 remains unaffected. Meanwhile the stack has no interim secondary management module as the switch reboots.

Secondary - Slot 1

Primary - Slot 2

4

When the rebooted switch comes back up, it assumes the secondary management role within the stack.

Reloading the Primary Management Module In a Stack of Two page 6-28 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Reloading Switches

Reloading the Secondary Management Module

If the switch with secondary management role is reloaded, the idle switch with the lowest slot number will automatically assume the secondary role. The reloaded switch (the former secondary) will assume an idle role when it comes back up.

Meanwhile, the switch with the primary management role, as well as any other idle modules in the stack, continue operations without interruption.

To reload the secondary management module, use the reload command. Be sure to include the syntax secondary in the command line. For example:

-> reload secondary

Note. A secondary management module reload can also be scheduled for a later time or date. For information on scheduling a secondary module reload, as well as additional command details, refer to the

OmniSwitch CLI Reference Guide.

Primary - Slot 1

Secondary - Slot 2

Idle - Slot 3

Idle - Slot 4

1

In this stack of four switches, the slot 1 switch is the primary management module. The slot 2 switch is the secondary. Slots 3 and 4 are operating in idle roles.

-> reload secondary

2

The user reloads the stack’s secondary management module by issuing the reload secondary command. Any data flow on the secondary switch’s Ethernet is interrupted.

Primary - Slot 1

Booting...

Secondary - Slot 3

Idle - Slot 4

Primary - Slot 1

Idle - Slot 2

Secondary - Slot 3

Idle - Slot 4

3

4

The idle switch with the lowest slot number—in this case, slot 3—automatically becomes the secondary management module. The slot 4 switch remains unaffected. In addition,

Ethernet traffic on slots 1, 3, and 4 remains unaffected.

When the rebooted switch comes back up, it assumes an idle role within the stack.

Reloading the Secondary Management Module In a Stack of Three or More

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-29

Reloading Switches Managing OmniSwitch 6850E Series Stacks

If there are only two switches in the stack, the switch that was reloaded (the former secondary) resumes the secondary role when it comes back up.

Primary - Slot 1

Secondary - Slot 2

1

In this stack of two switches, the slot 1 switch is the primary management module. The slot 2 switch is the secondary.

-> reload secondary

Primary - Slot 1

Booting...

2

The user reloads the stack’s secondary management module by issuing the reload secondary command. Any data flow on the secondary switch’s Ethernet is interrupted.

3

As the secondary switch reboots, the primary management module continues to operate without interruption. Meanwhile the stack has no interim secondary management module as the switch reboots.

Primary - Slot 1

Secondary - Slot 2

4

When the rebooted switch comes back up, it assumes the secondary management role within the stack.

Reloading the Secondary Management Module In a Stack of Two page 6-30 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Reloading Switches

Reloading Switches with Idle Roles

Similar to reloading Network Interface (NI) modules on chassis-based switches modules operating in idle status within a stack can be reloaded via the CLI.

Note. Any traffic being passed on the module’s Ethernet will be interrupted during the reboot. Other modules within the stack will continue to operate without interruption.

To reset a single module operating in idle mode, use the reload ni

command. Be sure to include the slot number of the idle switch in the command line. For example:

-> reload ni 3

Only one idle switch can be reloaded at a time. In order to reload multiple idle switches at once, the entire stack must be reloaded using the reload all command.

After reloading a switch operating in an idle role, the switch resumes idle status when it comes back up, despite its saved slot number. In other words, if an idle switch with a saved slot number of 1 is reloaded, it resumes its previous idle role. Although it has the lowest possible saved slot number, it does not take over the primary management role. In order for this switch to take over the primary role, all switches in the stack must be reloaded.

Note. For more information on reloading all the switches in a stack, refer to page 6-32 . For more informa-

tion on idle status, refer to page 6-12 .

Reloading Switches in Pass-Through Mode

Pass-through mode is a state in which a switch has attempted to join a stack but has been denied primary, secondary, and idle status. Because this is essentially an error state, the pass-through condition must be resolved and any modules operating in pass-through mode must be reloaded.

To reload a module operating in pass-through mode, use the reload pass-through

command. Be sure to include the slot number of the pass-through switch in the command line. For example:

-> reload pass-through 1001

Note. Before issuing the reload pass-through command, be sure to resolve any conditions causing the switch to operate in pass-through mode. Otherwise, the switch is likely to come up again in pass-through

mode. For detailed information, including steps used to recover from pass-through, refer to page 6-13 .

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-31

Reloading Switches Managing OmniSwitch 6850E Series Stacks

Reloading All Switches in a Stack

Reloading all switches in the stack is essentially a full reboot of the virtual chassis. This can be useful in restoring a stack’s previously configured topology—i.e., the stack’s saved slot numbers and management roles. Note, however, that all data flow on the stack is interrupted whenever a full reboot is issued.

To reset all switches in a stack use the reload all command. For example:

-> reload all

Important. Before issuing the reload all command, be sure to read the sections below. Understanding topics such as software synchronization and the effects of saved slot information can help users avoid unexpected results following a full stack reboot.

Software Synchronization During a Full Reload

If the checksum value on the stack’s non-primary switches differs in any way from the checksum value on the primary switch, the primary switch automatically distributes its system and configuration software to all other switches in the stack whenever a full reload is executed.

During this automatic software synchronization, system and configuration software on the secondary and idle switches is overwritten. Because the primary switch’s “last known good” software is propagated to all switches, the synchronization process helps ensure effective redundancy across the stack.

Effects of Saved Slot Number Information on the Reload Process

Depending on the status of saved slot information across the stack, there are different slot numbering and management role scenarios that can occur following a full reboot. For this reason, checking the current stack topology before issuing a full reboot is strongly recommended. To check the current stack topology, use the show stack topology

command. Refer to the OmniSwitch CLI Reference Guide for detailed command information.

Possible saved slot number conditions include:

All switches have unique saved slot information

No switches in the stack have saved slot information

Some switches have saved slot information, others do not

Two or more switches have duplicate slot information

All Switches Have Unique Saved Slot Information

If a full reload is issued and all switches have unique slot numbers saved to their boot.slot.cfg files, the slot numbers will be assigned according to the saved slot information. The primary management role will be given to the switch with the lowest saved slot number. The secondary management role will be given to the switch with the second-lowest saved slot number. All other switches will be assigned to idle roles.

An illustrated example of this method for assigning slot numbers and management roles is provided on pages

6-23

and 6-24

.

page 6-32 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Reloading Switches

No Switches In the Stack Have Saved Slot Information

If a full reload is issued and no switches in the stack have unique slot numbers, slot numbers will be assigned beginning with the switch with the lowest MAC address. (This can occur if the boot.slot.cfg file has been deleted from each switch’s /flash directory—e.g., by issuing the stack clear slot command for all modules in the stack.)

The switch with the lowest MAC address is assigned slot number 1 and given the primary management role. The switch connected to stacking port A of the primary switch is automatically assigned slot number 2 and given the secondary management role. Stack cabling is then used to determine the dynamic slot numbering of the remaining modules in the stack. The switch immediately adjacent to slot 2 is assigned slot number 3 and given an idle role, etc.

An illustrated example of this method for assigning slot numbers and management roles is provided on pages

6-21

and 6-22

.

Some Switches Have Saved Slot Information, Others Do Not

If only some switches in the stack have boot.slot.cfg files in their /flash directories, the system software will first read the contents of these files and then dynamically assigns unique slot numbers to any switches that do not have saved slot information. The primary management role will be given to the switch with the lowest saved slot number. The secondary management role will be given to the switch with the secondlowest saved slot number. All other switches will be assigned to idle roles.

When unique slot numbers are dynamically assigned by the system software, a boot.slot.cfg file is automatically generated with the new slot information. Because all switches now have unique saved slot information, any subsequent reload all commands issued will cause the stack to come up as described in the section,

“All Switches Have Unique Saved Slot Information” on page 6-32 .

Two or More Switches Have Duplicate Slot Information

If a full stack reboot is issued and the same slot number is found in the boot.slot.cfg file of two or more switches, the switch with the lowest MAC address is allowed to come up and operate normally. Meanwhile, any other switches with the duplicate slot number come up in pass-through mode.

The pass-through mode is essentially an error state in which a switch has been denied primary, secondary, and idle roles within the stack. When a switch is in pass-through mode, its Ethernet are brought down and cannot pass traffic. It is for this reason that users should always check the current saved slot number for each switch before issuing the reload all command. To check the current saved slot information across the stack, use the show stack topology

command. For detailed information on pass-through mode, refer to

“Pass-Through Mode” on page 6-13

.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-33

Reloading Switches Managing OmniSwitch 6850E Series Stacks

Avoiding Split Stacks

The term “splitting” a stack refers to the creation of isolated modules within the virtual chassis. A split stack can result from the following conditions:

Two or more non-adjacent switches are reloaded simultaneously

The stack is reloaded without a redundant stacking cable connection

The sections below offer simple guidelines for avoiding splitting the stack during the reload process.

Do Not Reload Non-Adjacent Switches Simultaneously

If non-adjacent switches in the stack—for example, the top switch in the stack and the third-from-top switch in the stack—are reloaded simultaneously, a problem will occur. The switch between the two nonadjacent switches will become isolated and the virtual chassis will be effectively split.

To avoid splitting the stack, do not reload the two non-adjacent switches simultaneously. Instead, simply reload the top switch first, then reload the third-from-top switch, or vice-versa.

Be Sure a Redundant Stacking Cable is Installed at All Times

Another important guideline for avoiding split stacks involves the redundant stacking cable. In order to avoid isolated modules within the virtual chassis, simply make sure that a redundant stacking cable connection exists between the top-most and bottom-most switches at all times.

For more information on the redundant stacking cable connection, refer to

page 6-18

.

page 6-34 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Changing the Secondary Module to Primary

Changing the Secondary Module to Primary

Stacks allow users to manually force the secondary switch to assume the primary management role. This is referred to as “takeover.” The behavior of a takeover is similar to that of reloading the primary management module (see

page 6-27

).

Whenever a takeover is initiated, the switch with the secondary role automatically takes over primary management functions. The primary switch is automatically reloaded and any traffic being passed on the primary switch’s Ethernet is interrupted.

Meanwhile, the idle switch with the next-lowest slot number automatically assumes the secondary role.

When the former primary module comes back up, it assumes an idle role within the stack.

To initiate a takeover sequence, use the takeover command. For example:

-> takeover

Note. Before using the takeover command, verify that the switches in the stack are synchronized.

Otherwise, data flow and switch management functions may be interrupted due to incorrect or outdated

software when a switch takes over the primary management role. For more information, refer to “Synchronizing Switches in a Stack” on page 6-37

.

Primary - Slot 1

Secondary - Slot 2

Idle - Slot 3

Idle - Slot 4

1

In this stack of four switches, the slot 1 switch is the primary management module. The slot 2 switch is the secondary. Slots 3 and 4 are operating in idle roles.

-> takeover

Booting...

Primary - Slot 2

Secondary - Slot 3

Idle - Slot 4

Idle - Slot 1

Primary - Slot 2

Secondary - Slot 3

Idle - Slot 4

2

A takeover is initiated by the user; the primary management module is automatically reloaded. Any data flow on the primary switch’s

Ethernet is interrupted.

3

The secondary switch takes over the primary role. The idle switch with the next-lowest slot number—in this case, slot 3—automatically becomes the secondary management module. The slot 4 switch remains unaffected. In addition, Ethernet traffic on slots 2, 3, and 4 remains unaffected.

4

When the former primary switch comes back up, it assumes an idle role within the stack.

Takeover Behavior In a Stack of Three or More

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-35

Changing the Secondary Module to Primary Managing OmniSwitch 6850E Series Stacks

If there are only two switches in the stack, the former primary switch resumes the secondary role when it comes back up following the takeover.

Primary - Slot 1

Secondary - Slot 2

1

In this stack of two switches, the slot 1 switch is the primary management module. The slot 2 switch is the secondary.

-> takeover

Booting...

Primary - Slot 2

2

A takeover is initiated by the user; the primary management module is automatically reloaded. Any data flow on the primary switch’s Ethernet is interrupted.

3

The secondary switch takes over the primary role. Ethernet traffic on slot 2 remains unaffected. Meanwhile the stack has no interim secondary management module as the switch reboots.

Secondary - Slot 1

Primary - Slot 2

4

When the former primary switch comes back up, it assumes the secondary management role within the stack.

Takeover Behavior In a Stack of Two page 6-36 OmniSwitch 6850E Series Hardware Users Guide

January 2013

Managing OmniSwitch 6850E Series Stacks Synchronizing Switches in a Stack

Synchronizing Switches in a Stack

Management module synchronization refers to the process of copying all files in the /flash/working and

/flash/certified directories of the primary management module to the /flash/working and /flash/certified directories of all the other switches in the stack. The system and configuration software on the nonprimary switches—i.e., the secondary management module and any modules operating in idle—is overwritten.

The synchronization process ensures that the contents of these directories match exactly for all switches across the stack. This can be especially useful after new software has been loaded to the primary management module. Further, synchronization prevents any switch from assuming a management role within the stack with incorrect or outdated software or configuration files. Because the primary switch’s “last known good” software is propagated to all switches, the synchronization process helps ensure effective redundancy across the stack.

In order to maintain effective management module redundancy, switches in the stack must be synchronized at all times. To determine whether a stack is in need of synchronization, use the show runningdirectory command. For example:

-> show running-configuration

CONFIGURATION STATUS

Running CMM : PRIMARY,

CMM Mode : DUAL CMMs,

Current CMM Slot : 1,

Running configuration : WORKING,

Certify/Restore Status : CERTIFY NEEDED

SYNCHRONIZATION STATUS

Flash Between CMMs : NOT SYNCHRONIZED,

Running Configuration : NOT AVAILABLE,

Stacks Reload on Takeover: PRIMARY ONLY

This example shows a switch on which the /flash directories between the management modules are not synchronized. To manually synchronize all switches in the stack, enter the following command:

-> copy working certified flash-syncro

When the synchronization process is initiated, modules within the stack continue to operate without interruption and data flow across the stack is unaffected.

Automatic Synchronization During a Full Reload

If the checksum value on the stack’s non-primary switches differs in any way from the checksum value on the primary switch, the primary switch automatically distributes its system and configuration software to all other switches in the stack whenever a full reload is executed.

For more information on initiating a full reload, see

“Reloading All Switches in a Stack” on page 6-32 .

Note. For more information on management module synchronization and managing the /flash/working and /flash/certified directories, refer to the “Managing CMM Directory Content” chapter in the Switch

Management Guide.

OmniSwitch 6850E Series Hardware Users Guide

January 2013

page 6-37

Monitoring the Stack Managing OmniSwitch 6850E Series Stacks

Monitoring the Stack

As shown in the previous sections, monitoring the current status and operation of all elements in a stack can help users avoid unexpected stack conditions. The table below includes CLI commands that are useful in monitoring stack conditions.

CLI Commands Used for Monitoring a Stack show stack topology show stack status show running-directory show chassis show cmm show ni show module show module long show module status show power show fan show temperature

Displays the current operating topology of switches within a stack.

Displays the current redundant stacking cable status and token availability for a stacked configuration.

Displays the directory from where the switch was booted. This command also shows important information, including whether the software across the stack is synchronized.

Displays basic configuration and status information for the switch chassis.

Displays basic hardware and status information for primary and secondary management modules operating in the stack.

Displays basic hardware and status information for modules currently operating in the stack.

Displays basic information for modules installed in the stack. Modules include primary and secondary management modules and any modules operating in idle status.

Displays detailed information for modules installed in the stack. Modules include primary and secondary management modules and any modules operating in idle status.

Displays basic status information for modules installed in the stack.

Modules include primary and secondary management modules and any modules operating in idle status.

Displays hardware information and current status for chassis power supplies. This includes the status of backup power supplies, if applicable.

Displays the current operating status of each of the six fans operating in each chassis.

Displays the current operating chassis ambient temperature, as well as current temperature threshold settings for each of the modules in the stack.

Visually Monitoring the Stack

Users can also monitor many stack operations by viewing the front panel LEDs on all elements in the stack. Refer to “Status LEDs” on page 2-53 for detailed information on LEDs and stack status.

page 6-38 OmniSwitch 6850E Series Hardware Users Guide

January 2013

A Regulatory Compliance and Safety Information

This appendix provides information on regulatory agency compliance and safety for OmniSwitch 6850E

Series switches.

Declaration of Conformity: CE Mark

This equipment is in compliance with the essential requirements and other provisions of

Directive 2004/108/EC (EMC), 2006/95/EC (LVD), 91/263/EEC (Telecom Terminal Equipment, if applicable), 1999/5/EC (R&TTE, if applicable).

Français: Cet équipement est conforme aux exigences essentielles et aux autres provisions de la Directive

2004/108/EC (EMC), 2006/95/CE (LVD), 91/263/CEE (équipements terminaux de télécommunications, le cas échéant), 1999/5/EC (R&TTE, le cas échéant).

Deutsch: Diese Ausrüstung erfüllt die wesentlichen Anforderungen und sonstigen Bestimmungen der

Richtlinien 2004/108/EG (EMV-Richtlinie), 2006/95/EG (Niederspannungsrichtlinie), 91/263/EWG

(Telekommunikationsendeinrichtungen, falls zutreffend), 1999/5/EG (Funkanlagen und Telekommunikationsendeinrichtungen, falls zutreffend).

Español: Este equipo cumple los requisitos esenciales y otras disposiciones de las directivas 2004/108/CE

(EMC), 2006/95/CE (LVD), 91/263/CEE (equipos terminales de telecomunicación, si procede), 1999/5/

CE (R&TTE, si procede).

Waste Electrical and Electronic Equipment (WEEE) Statement

The product at end of life is subject to separate collection and treatment in the EU Member States, Norway and Switzerland and therefore marked with the following symbol:

Treatment applied at end of life of the product in these countries shall comply with the applicable national laws implementing directive 2002/96/EC on waste electrical and electronic equipment (WEEE).

OmniSwitch 6850E Hardware Users Guide

January 2013

page A-1

China RoHS: Hazardous Substance Table Regulatory Compliance and Safety Information

China RoHS: Hazardous Substance Table

SUPPLEMENT TO PRODUCT INSTRUCTIONS

Include this document with all Electronic Information Products imported or sold in the People’s Republic of China

部件名称

(Parts)

( Pb)

( Hg)

有毒有害物质或元素 (Hazardous Substance)

( Cd)

六价铬

( Cr 6+ )

多溴联苯

( PBB)

多溴二苯醚

( PBDE)

电路模块

(

Circuit Modules)

×

○ ○ ○ ○ ○

电缆及电缆组件

(

Cables & Cable Assemblies)

金属部件

(Metal Parts)

塑料和聚合物部件

(Plastic and Polymeric parts)

×

×

对于交付时集成了电池的电子信息产品

For electronic information products delivered with integrated functional batteries:

电池

(Batteries)

○ ○ ○ ○ ○ ○

○ : 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/ T11363- 2006 标准规定的限量要求以下。

Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T11363-2006 standard.

×

: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出SJ/ T11363- 2006标准规定的限量要求。

Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard.

对销售之日的所售产品, 本表显示, 阿尔卡特朗讯公司供应链的电子信息产品可能包含这些物质。注意: 在所售产

品中可能会也可能不会含有所有所列的部件。

This table shows where these substances may be found in the supply chain of Alcatel-Lucent electronic information products, as of the date of sale of the enclosed product. Note that some of the component types listed above may or may not be a part of the enclosed product.

除非另外特别的标注, 此标志为针对所涉及产品的环保使用期标志. 某些零部件会有

一个不同的环保使用期( 例如, 电池单元模块) 贴在其产品上.

此环保使用期限只适用于产品是在产品手册中所规定的条件下工作.

The Environment- Friendly Use Period (EFUP) for all enclosed products and their parts are per the symbol shown here, unless otherwise marked. Certain parts may have a different

EFUP (for example, battery modules) and so are marked to reflect such. The Environment-

Friendly Use Period is valid only when the product is operated under the conditions defined in the product manual.

50 page A-2 OmniSwitch 6850E Hardware Users Guide

January 2013

Regulatory Compliance and Safety Information China RoHS: Hazardous Substance Table

Products are packaged using one or more of the following packaging materials:

CB

FB

Corrugated Cardboard Corrugated Fiberboard Low-Density Polyethylene

OmniSwitch 6850E Hardware Users Guide

January 2013

page A-3

Standards Compliance Regulatory Compliance and Safety Information

Standards Compliance

The product bears the CE mark. In addition it is in compliance with the following other safety and EMC standards:

All hardware switching modules used in an OmniSwitch 6850/6850E switch comply with Class A standards. Modules with copper connectors meet Class A requirements using unshielded (UTP) cables.

Safety Standards

UL 60950-1, 2nd Edition

CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition

EN 60950-1 with Amendment II

IEC 60950-1 2nd Edition

AS/NZS TS-001 and 60950, Australia

UL-AR, Argentina

TUV,UL-GS Mark, Germany

NOM-019 SCFI, Mexico

EN 60825-1 Laser

EN 60825-2 Laser

CDRH Laser

CB Certification per IEC 60950-1, Second Edition

EMC Standards

FCC Part 15 (CFR 47) Class A

ICES-003 Class A

EN 55022 Class A

CISPR 22 Class A

AS/NZS 3548 Class A

VCCI Class A; A1 and A2

EN 55024 (Immunity)

EN 61000-3-2

EN 61000-3-3

EN 61000-4-2

EN 61000-4-3

EN 61000-4-4

EN 61000-4-5

EN 61000-4-6

EN 61000-4-8

EN 61000-4-11 page A-4 OmniSwitch 6850E Hardware Users Guide

January 2013

Regulatory Compliance and Safety Information

Environmental Standards

ETS 300 019 Storage Class 1.1

ETS 300 019 Transportation Class 2.3

ETS 300 019 Stationary Use Class 3.1

NEBS Compliance Statements

NEBS Compliance Statements

The following statements apply to OS6850E non-PoE models OS6850E-24, OS6850E-24X, OS6850E-48,

OS6850E-48X and OS6850E-U24X.

Intended Installation Locations

Network telecommunications facilities

Customer premises

Installation must be in a location where a Surge Protective Device (SPD) is used for the AC power service entrance.

Battery Return Configuration

The Battery Return (BR) configuration will be either Isolated dc return (DC-I) or

Common dc return (DC-C)

Note. The ampacity of the conductor connecting the equipment frame to the BR conductor shall be equal to or greater than the ampacity of the associated BR conductor.

Equipment Grounding

For grounding, use Panduit Lug:

Panduit P/N:

Copper Conductor Size:

Screw Size:

Torque:

LCD8-10A-L

8 AWG

10-32 (Thread Size)

25.0 +/- 2.0 (inch lb)

Installation is suitable as part of the Common Bonding Network (CBN).

OmniSwitch 6850E Hardware Users Guide

January 2013

page A-5

NEBS Compliance Statements Regulatory Compliance and Safety Information

FCC Class A, Part 15

This equipment has been tested and found to comply with the limits for Class A digital device pursuant to

Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this guide, may cause interference to radio communications.Operation of this equipment in a residential area is likely to cause interference, in which case the user will be required to correct the interference at his own expense.

The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the user’s authority to operate this equipment.It is suggested that the user use only shielded and grounded cables to ensure compliance with FCC Rules.

If this equipment does cause interference to radio or television reception, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient the receiving antenna.

Relocate the equipment with respect to the receiver.

Move the equipment away from the receiver.

Plug the equipment into a different outlet so that equipment and receiver are on different branch circuits.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions.

Canada Class A Statement

This equipment does not exceed Class A limits per radio noise emissions for digital apparatus, set out in the Radio Interference Regulation of the Canadian Department of Communications.

Avis de conformitè aux normes du ministère des Communications du Canada

Cet èquipement ne dèpasse pas les limites de Classe A d íèmission de bruits radioèlectriques pour les appareils numèriques,telles que prescrites par le RÈglement sur le brouillage radioèlectrique ètabli par le ministère des Communications du Canada.

JATE

This equipment meets the requirements of the Japan Approvals Institute of Telecommunications

Equipment (JATE).

CISPR22 Class A warning

This is a Class A product. In a domestic environment, this product may cause radio interference. Under such circumstances, the user may be requested to take appropriate countermeasures.

page A-6 OmniSwitch 6850E Hardware Users Guide

January 2013

Regulatory Compliance and Safety Information NEBS Compliance Statements

VCCI

This is a Class A product based on the standard of the Voluntary Control Council for Interference by

Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.

Class A Warning for Taiwan and Other Chinese Markets

This is a Class A Information Product. When used in a residential environment, it may cause radio frequency interference. Under such circumstances, the user may be requested to take appropriate countermeasure.

OmniSwitch 6850E Hardware Users Guide

January 2013

page A-7

Translated Safety Warnings Regulatory Compliance and Safety Information

Translated Safety Warnings

Chassis Lifting Warning

Two people are required when lifting the chassis. Due to its weight, lifting the chassis unassisted can cause personal injury. Also be sure to bend your knees and keep your back straight when assisting with the lifting of the chassis.

Français: Le châssis doit être soulevé par deux personnes au minimum. Pour éviter tout risque d'accident, maintenez le dos droit et poussez sur vos jambes. Ne soulevez pas l'unité avec votre dos.

Deutsch: Hinweise zur Anhebung des Chassis Zum Anheben des Chassis werden zwei Personen benötigt.

Aufgrund des Gewichts kann das Anheben ohne Unterstützung zu Personenschäden führen. Heben Sie das

Chassis aus den Knien und halten Sie den Rücken gerade wenn Sie beim Anheben des Chassis assistieren.

Español: Se requieren dos personas para elevar el chasis. Para evitar lesiones, mantenga su espalda en posición recta y levante con sus piernas, no con su espalda.

Blank Panels Warning

Because they regulate airflow and help protect internal chassis components, blank cover plates should remain installed at empty module slots and power supply bays at all times.

Français: Les caches blancs remplissent trois fonctions importantes: ils évitent tout risque de choc

électrique à l'intérieur du châssis, ils font barrage aux interférences électromagnétiques susceptibles d'altérer le fonctionnement des autres équipements et ils dirigent le flux d'air de refroidissement dans le châssis. Il est vivement recommandé de vérifier que tous les caches, modules d'alimentation et plaques de protection sont en place avant d'utiliser le système.

Deutsch: Die leeren Modulblenden schützen interne Komponenten und leiten den Luftstrom. Deshalb müssen in allen unbelegten Slots die Modulblenden immer installiert bleiben.

Español: Las tapaderas blancas regulan la circulación de aire y ayudan a proteger componentes internos del chasis y siempre deben estar instaladas en las ranuras vacías del chasis y fuentes de alimentación.

Electrical Storm Warning

To avoid a shock hazard, do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm.

Français: Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage.

Deutsch: Um elektrische Schläge zu vermeiden dürfen während eines Gewitters and diesem Gerät keine

Kabel angeschlossen oder gelöst werden, sowie keinerlei Installationen, Wartungen oder Konfigurationen vorgenommen werden.

Español: Para evitar peligro de descargas, no conecte o desconecte ningun cable, ni realice ninguna instalación, maintenimiento o reconfiguración de este producto durante una tormenta eléctrica.

page A-8 OmniSwitch 6850E Hardware Users Guide

January 2013

Regulatory Compliance and Safety Information Translated Safety Warnings

Installation Warning

Only personnel knowledgeable in basic electrical and mechanical procedures should install or maintain this equipment.

Français: Toute installation ou remplacement de l'appareil doit être réalisée par du personnel qualifié et compétent.

Deutsch: Dieses Gerät soll nur von Personal installiert oder gewartet werden, welches in elektrischen und mechanischen Grundlagen ausgebildet ist.

Español: Estos equipos deben ser instalados y atendidos exclusivamente por personal adecuadamente formado y capacitado en técnicas eléctricas y mecánicas.

Invisible Laser Radiation Warning

Lasers emit invisible radiation from the aperture opening when no fiber-optic cable is connected. When removing cables do not stare into the open apertures. In addition, install protective aperture covers to fiber ports with no cable connected.

Français: Des radiations invisibles à l'œil nu pouvant traverser l'ouverture du port lorsque aucun câble en fibre optique n'y est connecté, il est recommandé de ne pas regarder fixement l'intérieur de ces ouvertures.

Installez les caches connecteurs prévus à cet effet.

Deutsch: Die Laser strahlen an der Blendenöffnung unsichtbares Licht ab, wenn keine Glasfaserkabel angeschlossen sind. Blicken Sie nicht in die Öffnungen und installieren Sie unverzüglich die

Abdeckungen über den Glasfaseranschlüssen.

Español: Debido a que la apertura del puerto puede emitir radiación invisible cuando no hay un cable de fibra conectado, procurar no mirar directamente a las aperturas para no exponerse a la radiación.

Operating Voltage Warning

To reduce the risk of electrical shock, keep your hands and fingers out of power supply bays and do not touch the backplane while the switch is operating.

Français: Pour réduire tout risque électrique, gardez vos mains et doigts hors des alimentations et ne touchez pas au fond de panier pendant que le commutateur fonctionne.

Deutsch: Um die Gefahr des elektrischen Schlages zu verringern, greifen sie bitte nicht in die

Spannungsversorgung und berühren sie nicht die Rückwandplatine während das Gerät arbeitet.

Español: Para reducir el riesgo de descargas eléctricas, no meta sus manos y dedos dentro del chasis de la fuente de alimentación y no toque componentes internos mientras que el interruptor está conectado.

OmniSwitch 6850E Hardware Users Guide

January 2013

page A-9

Translated Safety Warnings Regulatory Compliance and Safety Information

Power Disconnection Warning

Your switch is equipped with multiple power supplies. To reduce the risk of electrical shock, be sure to disconnect all power connections before servicing or moving the unit.

Français: Il se peut que cette unité soit équipée de plusieurs raccordements d'alimentation. Pour supprimer tout courant électrique de l'unité, tous les cordons d'alimentation doivent être débranchés.

Deutsch: Ihr Gerät ist mit mehreren Netzteilen ausgerüstet. Um die Gefahr des elektrischen Schlages zu verringern, stellen sie sicher, daß alle Netzverbindungen getrennt sind bevor das Gerät gewartet oder bewegt wird.

Español: Antes de empezar a trabajar con un sistema, asegurese que el interruptor está cerrado y el cable eléctrico desconectado.

Proper Earthing Requirement Warning

To avoid shock hazard:

The power cord must be connected to a properly wired and earth receptacle.

Any equipment to which this product will attached must also be connected to properly wired receptacles.

Français:

Pour éviter tout risque de choc électrique:

Ne jamais rendre inopérant le conducteur de masse ni utiliser l'équipement sans un conducteur de masse adéquatement installé.

En cas de doute sur la mise à la masse appropriée disponible, s'adresser à l'organisme responsable de la sécurité électrique ou à un électricien.

Deutsch:

Aus Sicherheitsgründen:

darf das Netzkabel nur an eine Schutzkontaktsteckdose angeschloossen werden.

dürfen für den Anschluß anderer Geräte, welche mit diesem Gerät verbunden sind, auch nur

Schutzkontaktsteckdosen verwendet werden.

Español:

Para evitar peligro de descargas:

Para evitar peligro de descargas asegurese de que el cable de alimentación está conectado a una toma de alimentación adecuadamente cableada y con toma de tierra.

Cualquier otro equipo a cual se conecte este producto también debe estar conectado a tomas de alimentación adecuadamente cableadas.

page A-10 OmniSwitch 6850E Hardware Users Guide

January 2013

Regulatory Compliance and Safety Information DC Power Supply Connection Warning

DC Power Supply Connection Warning

For EMC/EMI, each DC/DC power supply requires that the ground wire is connected from each DC/DC power supply to Common Earth Ground.

Français: Pour EMC/EMI, pour chaque alimentation DC/DC, il est impératif que le fil de terre soit branché à la prise de terre commune.

Deutsch: Zur Erfüllung der EMV-/EMI-Anforderungen muss das Erdungskabel jedes DC/DC-Netzteils an eine gemeinsame Erde angeschlossen werden.

Español: Para EMC/EMI, cada fuente de alimentación de CC/CC requiere que el cable de tierra esté conectado desde cada fuente de alimentación de CC/CC a la conexión a tierra común.

Read Important Safety Information Warning

The Getting Started Guide that accompanied this equipment contains important safety information about which you should be aware when working with hardware components in this system. You should read this guide before installing, using, or servicing this equipment.

Français: Avant de brancher le système sur la source d'alimentation, consultez les directives d'installation disponibles dans le “Getting Started Guide”.

Deutsch: Der Getting Started Guide, welcher diese Anlage beiliegt, enthält wichtige

Sicherheitsinformationen, über die sie sich beim Arbeiten mit den Hardwareeinheiten bewußt sein sollten.

Sie sollten diese Hinweise lesen, bevor sie installieren, reparieren oder die Anlage verwenden.

Español: La 'Getting Started Guide' que acompañó este equipo contiene información importante de seguridad sobre la cual usted debe estar enterado al trabajar con los componentes de dotación física en este sistema. Usted debe leer esta guía antes de instalar, usar o mantener este equipo.

Restricted Access Location Warning

This equipment should be installed in a location that restricts access. A restricted access location is one where access is secure and limited to service personnel who have a special key, or other means of security.

Français: Le matériel doit être installé dans un local avec accès limité ou seules les personnes habilitées peuvent entrer.

Deutsch: Die Anlage sollte an einem Standort mit beschränktem Zutritt installiert sein. Ein Standort mit beschränktem Zutritt stellt sicher, daß dort nur Servicepersonal mit Hilfe eines Schlüssels oder eines anderen Sicherheitssystems Zugang hat.

Español: Este equipo se debe instalar en un sitio con acceso restrinjido. Un sitio con el acceso restrinjido es uno seguro y con acceso limitado al personal de servicio que tiene una clave especial u otros medios de seguridad.

OmniSwitch 6850E Hardware Users Guide

January 2013

page A-11

DC Power Supply Connection Warning Regulatory Compliance and Safety Information

Wrist Strap Warning

Because electrostatic discharge (ESD) can damage switch components, you must follow proper procedures to eliminate ESD from your person and the surrounding area before handling switch components. A grounding wrist strap is provided with your Alcatel-Lucent OmniSwitch 6850E Series product.

Français: L'électricité statique (ESD) peut endommager les composants du commutateur. Pour cette raison Alcatel-Lucent joint à l'envoi du châssis un bracelet antistatique à brancher sur la prise mise à la terre située en bas à droite du commutateur. Vous devrez mettre ce bracelet avant toute intervention hardware.

Deutsch: Weil elektrostatische Aufladung (ESD) Teile der Anlage beschädigen könnten, müssen sie sich selbst erden, bevor sie mit der Hardware Installation beginnen. Zu diesem Zweck stellt Alcatel-Lucent ein

Erdungsarmband und eine Erdungsöse an der oberen rechten Seite des Chassis zur Verfügung. Um eine sichere Erdungsfunktion des Erdungsarmbandes sicherzustellen, müssen die Netzteile installiert und mit dem Schutzleiter des Versorgungsstromkreises verbunden sein.

Español: La descarga electrostática (ESD) puede dañar componentes eletrónicos. Usted debe asegurarse que está en contacto con tierra antes de hacer la instalación del equipo. Con este fin, Alcatel-Lucent proporciona una pulsera de muñeca para conectar al chasis en la toma de tierra situada en la parte superior derecha del chasis. Para que la correa de muñeca sea eficaz en la eliminación de ESD, las fuentes de alimentación deben estar instaladas en el chasis y conectadas a enchufes CA con tierra adecuada.

page A-12 OmniSwitch 6850E Hardware Users Guide

January 2013

Regulatory Compliance and Safety Information Instrucciones de seguridad en español

Instrucciones de seguridad en español

Advertencia sobre el levantamiento del chasis

Se requieren dos personas para levantar el chasis. Debido a su peso, la elevación del chasis sin ayuda puede causar daños corporales. También es seguro doblar sus rodillas y guardar su espalda derecho al ayudar a levantar el chasis.

Advertencia de las tapaderas en blanco

Porque regulan la circulación de aire y ayudan a proteger componentes internos del chasis, las tapaderas en blanco deben seguir instaladas en las ranuras vacías del módulo y la fuente de alimentación siempre.

Advertencia en caso de tormenta eléctrica

Para evitar peligro de descargas, no conecte o desconecte ningun cable, ni realice ninguna instalación, maintenimiento o reconfiguratión de este producto durante una tormenta eléctrica.

Advertencia de instalación

Solamente el personal bien informado en procedimientos eléctricos y mecánicos básicos debe instalar o mantener este equipo.

Advertencia de radiación láser invisible

Los lasers emiten radiación invisible de la apertura abierta cuando no se conecta ningún cable de fibra

óptica. Al quitar los cables no mire fijamente en las aberturas abiertas. Además, instale las cubiertas protectoras de la abertura a las salidas de la fibra sin el cable conectado.

Advertencia de la batería de litio

Hay un peligro de la explosión si la batería del litio en su chasis se substituye incorrectamente. Substituya la batería solamente por el mismo o el equivalente de tipo de batería recomendado por el fabricante.

Deseche las baterías usadas según las instrucciones del fabricante. Las instrucciones del fabricante son como sigue: Devuelva el módulo con la batería del litio a Alcatel-Lucent. La batería del litio será substituida en la fábrica de Alcatel-Lucent.

Advertencia sobre la tensión de operación

Para reducir el riesgo del choque eléctrico, matenga sus manos y dedos fuera de la fuente de alimentación y no toque la placa madre mientras que el interruptor está funcionando.

Advertencia sobre la desconexión de la fuente

Su interruptor esta equipado por fuentes de alimentación múltiples. Para reducir el riesgo de choque eléctrico, asegúrese desconectar todas las conexiones de alimentación antes de mantener o de mover la unidad.

OmniSwitch 6850E Hardware Users Guide

January 2013

page A-13

Instrucciones de seguridad en español Regulatory Compliance and Safety Information

Advertencia sobre una apropiada conexión a tierra

Para evitar peligro de descargas:

El cable de alimentación debe estar conectado a una toma de alimentación adecuadamente cableada y con toma de tierra.

Cualquier equipo al cual se conecte este producto debe estar también conectado a tomas de alimentación adecuadamente cableadas.

Leer “información importante de seguridad”

La Guía de “Comenzando a Usar” que acompaña este equipo contiene información importante de seguridad sobre la cual usted debe saber al trabajar con los componentes de dotación física en este sistema.

Usted debe leer esta guía antes de instalar, de usar, o de mantener este equipo.

Advertencia de acceso restringido

Este equipo se debe instalar en una ubicación que restrinja el acceso. Una ubicación con acceso restringido es una donde está seguro y limitado el acceso al personal de servicio que tiene un clave especial, u otros medios de la seguridad.

Advertencia de pulsera antiestática

Debido a que la descarga electrostática (ESD) puede dañar componentes del interruptor, usted debe conectarse a tierra correctamente antes de continuar con la instalación del equipo. Para este propósito,

Alcatel-Lucent proporciona una pulsera antiestática y un terminal que pone a tierra situados cerca de la parte superior derecha del chasis. Para que la pulsera antiestática sea eficaz en la eliminación de ESD, las fuentes de alimentación se deben instalar en el chasis y enchufar en las salidas de CA con descarga a tierra.

Clase de seguridad

Cumple con 21CFR 1040.10 y 1040.11 ó sus equivalentes.

Advertencia de fuentes de poder

Las unidades OmniSwitch 6850/6850E pueden estar equipadas con tres cordones para fuente de poder.

Para reducir el riesgo de un choque electrico, desconecte todos los cordones de fuente de poder antes de dar servicio a la unidad.

page A-14 OmniSwitch 6850E Hardware Users Guide

January 2013

Index

hot swapping

1-3, 6-25

modules in a stack

6-25

Numerics

10/100/1000 LEDs

2-31

10000 XFP 1 LEDs

2-31

I

idle modules

6-12

reloading

6-31

image rollback

see software rollback

Inline Power

see PoE

A

availability

1-2

hardware monitoring

1-3, 6-38

hot swapping

1-3

software rollback

1-2

B

blank cover panels

2-34

boot serialbaudrate command

2-44

boot serialparity command

2-44

boot serialtopbits command

2-45

boot serialwordsize command

2-44

boot.params command

2-45

C

chassis airflow

2-32, 2-33

booting

2-41

installation options

2-35

installing

2-32

monitoring

3-19

rack-mounting

2-36

rear panel

2-3, 2-6, 2-9, 2-12, 2-15, 2-18, 2-21, 2-24, 2-27

tabletop

2-35

commit file command

2-45

commit system command

2-45

console port

2-44, 2-47

default settings

2-30, 2-44

modifying default settings

2-44

D

DC power supplies

3-15

defaults

PoE

5-5

L

lanpower capacitor-detection command

5-8

lanpower maxpower command

5-7

lanpower power command

5-6

lanpower priority command

5-7

lanpower priority-disconnect command

5-9

lanpower start command

5-6

lanpower stop command

5-6

LEDs

see hardware monitoring

M

management roles changing the secondary to primary

6-35

reloading a stack

6-32

synchronizing primary and secondary

6-37

modify boot parameters command

2-44

O

OmniSwitch 6850-24

2-2

technical specifications

2-4

OmniSwitch 6850-48 technical specifications

2-16

OmniSwitch 6850-P24 technical specifications

2-7

OmniSwitch 6850-P48 technical specifications

2-19, 2-22, 2-25, 2-28

OmniSwitch 6850-U24X technical specifications

2-10, 2-13

OmniSwitch Backup Power Shelf/System (BPS)

see OS-BPS

OmniSwitch BPS

see OS-BPS

OS-BPS rack-mounting

4-9

supplemental ground

4-21

E

exit command

2-45

H

hardware monitoring

1-3, 3-19, 6-38

automatic

1-3

LEDs

1-3, 2-42

user-driven

1-3

P

pass-through modules

6-13

reloading

6-31

pinouts

2-46

PoE

5-1

defaults

5-5

monitoring

5-4, 5-12

priority disconnect

5-9

OmniSwitch 6850E Series Hardware Users Guide

January 2013

Index-1

Index specifications

5-3

PoE Power Shelf monitoring

5-4

power cord specifications

2-43

power cords

2-43

Power on LAN

see PoE

Power over Ethernet

see PoE

Power over LAN

see PoE

power supplies

3-2, 4-13, 4-15

OS-BPS

4-13

PS-126W AC power supply

3-9

PS-360W AC power supply

3-9

power supply connecting a DC power source

3-15

power supply shelf

3-3

primary management module

6-4

dynamic selection

6-7

reloading

6-27

R

reload all command

6-31

reload command

6-27

reload ni command

6-31

reload pass-through command

6-31

S

secondary management module

6-4

dynamic selection

6-10

reloading

6-29

show command

2-45

show chassis command

3-19, 6-38

show cmm command

3-20, 6-38

show fan command

3-20, 6-38

show lanpower command

5-12

show module command

3-20, 6-20

show module long command

3-20, 6-38

show module status command

3-20, 6-38

show ni command

3-20, 6-20

show power command

3-18, 6-38

show stack status command

6-19

show stack topology command

2-29, 6-13

show temperature command

3-19, 6-38

slot numbering

6-20

software rollback

1-2

software synchronization

6-37

specifications

PoE

5-3

power cord

2-43

stack clear slot command

6-24

stack set slot command

6-14

stacks

6-1

booting

2-42

cabling

2-38, 6-17

idle modules

6-12

Index-2 management roles

6-4

merging

6-26

monitoring

6-38

pass-through modules

6-13

rack-mounting

2-38

reloading

6-27, 6-32

setup

2-38

T

takeover command

6-35

technical specifications console port

2-44, 2-47

OmniSwitch 6850-24

2-4

OmniSwitch 6850-48

2-16

OmniSwitch 6850-P24

2-7

OmniSwitch 6850-P48

2-19, 2-22, 2-25, 2-28

OmniSwitch 6850-U24X

2-10, 2-13

pinouts

2-46

OmniSwitch 6850E Series Hardware Users Guide

January 2013

advertisement

Related manuals

Download PDF

advertisement