Lucent Technologies CellPipe IAD 4S, 8S, 8T, 4A Integrated Access Device User’s Guide
PDF
Documento
Anuncio
Anuncio
CellPipe™ IAD Series User’s Guide Part Number: 7820-0715-003 For software version 3.1 November 2001 Copyright © 2001 Lucent Technologies Inc. All rights reserved. This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts, or licensing, without the express written consent of Lucent Technologies. For permission to reproduce or distribute, please email your request to [email protected]. Notice Every effort was made to ensure that the information in this document was complete and accurate at the time of printing, but information is subject to change. European Community (EC) RTTE Compliance Hereby, Lucent Technologies, declares that the equipment documented in this publication is in compliance with the essential requirements and other relevant provisions of the Radio and Telecommunications Technical Equipment (RTTE) Directive 1999/5/EC. To view the official Declaration of Conformity certificate for this equipment, according to EN 45014, access the Lucent INS online documentation library at http://www.lucent.com/ins/doclibrary/. Safety, Compliance, and Warranty Information Before handling any Lucent Access Networks hardware product, read the Edge Access Safety and Compliance Guide included in your product package. See that guide also to determine how products comply with the electromagnetic interference (EMI) and network compatibility requirements of your country. See the warranty card included in your product package for the limited warranty that Lucent Technologies provides for its products. Security Statement In rare instances, unauthorized individuals make connections to the telecommunications network through the use of access features. Trademarks Lucent, the Lucent logo, and all Lucent brand and product names are trademarks or registered trademarks of Lucent Technologies Inc. Other brand and product names are trademarks of their respective holders. Ordering Information You can order the most up-to-date product information and computer-based training online at http://www.lucent.com/ins/bookstore. Feedback Lucent Technologies appreciates customer comments about this manual. Please send them to [email protected]. Customer Service Lucent Technologies is the value added reseller (VAR) of certain CellPipe products. To ensure you receive the latest and most up-to-date information in a timely manner, Lucent is providing you with the latest original equipment manufacturer (OEM) documentation. Thus, references to both Lucent and the OEM might appear in the documentation. Lucent and its OEMs hope their combined efforts result in the best documentation for the existing range of products. Finding information and software To obtain software upgrades and documentation for these products, log in to the Lucent OnLine Customer Support at http://www.lucent.com/support. The center is open 24 hours a day, seven days a week. Obtaining technical assistance Lucent OnLine Customer Support at http://www.lucent.com/support also provides easy access to technical support. You can obtain technical assistance through email or the Internet, or by telephone. If you need assistance, make sure that you have the following information available: • • • • • • • • • Active service or maintenance contract number, entitlement ID, or site ID Product name, model, and serial number Software version or release number Software and hardware options If supplied by your carrier, service profile identifiers (SPIDs) associated with your line Your local telephone company’s switch type and operating mode, such as AT&T 5ESS Custom or Northern Telecom National ISDN-1 Whether you are routing or bridging with your Lucent product Type of computer you are using Description of the problem Obtaining assistance through email or the Internet If your services agreement allows, you can communicate directly with a technical engineer through Email Technical Support or a Live Chat. Select one of these sites when you log in to http://www.lucent.com/support. Lucent Technologies -i- CellPipe™ IAD Series User’s Guide Calling the technical assistance center (TAC) If you cannot find an answer through the tools and information of Lucent OnLine Customer Support or if you have a very urgent need, contact TAC. Access Lucent OnLine Customer Support at http://www.lucent.com/support and click Contact Us for a list of telephone numbers inside and outside the United States. Alternatively, call 1-866-LUCENT8 (1-866-582-3688) from any location in North America for a menu of Lucent services. If you do not have an active services agreement or contract, you will be charged for time and materials. Lucent Technologies - ii - CellPipe™ IAD Series User’s Guide 7DEOHRIFRQWHQWV 1. Introduction .................................................................... 1 Organization of this guide ........................................................1 2. CellPipe IAD basics........................................................ 3 Hardware and software requirements......................................3 Connectors ..............................................................................3 DC Power Input............................................................................ 3 Console cable ............................................................................... 3 Interfaces ...................................................................................... 3 Power/status Indicators ...........................................................4 3. Getting started ............................................................... 5 Connecting ..............................................................................5 Connecting two Ethernet devices ................................................. 5 Logging on...............................................................................6 Using a terminal emulation program............................................ 6 Using a Telnet program ................................................................ 7 Menu interface.......................................................................10 Default values............................................................................. 11 Restarting ..............................................................................11 Auto Log off ...........................................................................12 Lucent Technologies - iii - CellPipe™ IAD Series User’s Guide Exiting....................................................................................12 Verifying an IP address..........................................................12 A computer running Windows 95/98/Me/2000.......................... 12 The CellPipe IADs ..................................................................... 13 4. Menu interface.............................................................. 14 Main Menu.............................................................................14 1. Reports Menu ....................................................................15 C. Display Current Configuration .............................................. 15 N. Display Network Statistics .................................................... 17 I. Display Interface Statistics...................................................... 18 M. Display Media Statistics ....................................................... 18 R. Display Route Table .............................................................. 20 A. Display ARP Table................................................................ 20 B. Display Bridge forwarding database ..................................... 20 S. Display Bridge status ............................................................. 21 P. Display PPP Authorization Entries ........................................ 21 U. Display System Uptime......................................................... 21 O. Display Memory Statistic ...................................................... 22 2. Configure IP Router ...........................................................24 C. Configure Port IP Address..................................................... 25 U. Unconfigure Port IP Address................................................. 25 S. Add/Remove a Static Route ................................................... 25 R. Enable/Disable RIP................................................................ 26 V. Configure RIP Version by Port ............................................. 26 P. Configure RIP Poisoned Reverse by Port .............................. 26 N. Configure DNS Client ........................................................... 27 H. Configure DHCP Client ........................................................ 27 L. Configure DHCP Relay ......................................................... 27 T. Configure Telnet Server Port ................................................. 28 Lucent Technologies - iv - CellPipe™ IAD Series User’s Guide F. Configure IP Filtering ............................................................ 28 D. Display Route Table .............................................................. 32 3. Configure Bridge................................................................34 G. Enable/Disable Bridging Globally ........................................ 35 P. Enable/Disable Bridging by Port ........................................... 35 A. Configure Bridge Aging Timer ............................................. 35 T. Enable/Disable Spanning Tree Globally................................ 35 O. Enable/Disable Spanning Tree by Port.................................. 35 R. Configure Spanning Tree Bridge Priority.............................. 35 Q. Configure Spanning Tree Port Priority.................................. 36 H. Configure Spanning Tree Hello Time ................................... 36 S. Configure Spanning Tree Max Age ....................................... 36 F. Configure Spanning Tree Forward Delay .............................. 36 C. Configure Spanning Tree Path Cost ...................................... 37 D. Delete Bridge Forwarding Database Entry............................ 37 5. Configure WAN..................................................................38 0. Quick Configuration (CellPipe IAD 4S/8S)........................... 39 1. Configure Datalink Protocol .................................................. 39 2. Configure Physical Interface .................................................. 40 3. Configure DLCIs (Frame Relay)............................................ 45 3. Configure PVCS (ATM) ........................................................ 47 4. Configure FR Options (Frame Relay) .................................... 52 4. Configure ATM Options (ATM)............................................ 54 6. Configure LAN ...................................................................55 F. Set/Clear Full Duplex............................................................. 55 7. Configure SNMP................................................................55 E. Enable/Disable SNMP ........................................................... 56 P. Configure System Contact ..................................................... 56 N. Configure System Name........................................................ 56 L. Configure System Location ................................................... 56 C. Configure SNMP Community ............................................... 56 T. Configure SNMP Trap Host IP Address................................ 56 Lucent Technologies -v- CellPipe™ IAD Series User’s Guide 8. Configure Login .................................................................56 1. Change User ID ...................................................................... 57 2. Change User Password........................................................... 57 3. Change NetMan Password ..................................................... 57 4. Change Supervisor Password ................................................. 57 5. Change Primary RADIUS Server Address ............................ 57 6. Change Primary RADIUS Encryption Secret ........................ 58 7. Change Secondary RADIUS Server Address ........................ 58 8. Change Secondary RADIUS Encryption Secret .................... 58 9. Display RADIUS Configuration ............................................ 58 9. System Utilities ..................................................................58 P. Ping Utility ............................................................................. 59 T. Trace Route ............................................................................ 59 Z. Configure Console Baud Rate................................................ 59 V. Configure Console Timeout .................................................. 59 R. Hard Reset or Reload ACOS from FLASH........................... 60 D. Set System Defaults............................................................... 60 W. Save System Settings as Defaults ......................................... 60 A. Clear ’Last Reset Reason’...................................................... 60 F. File System Menu .................................................................. 60 G. Debug Menu .......................................................................... 61 X. File Transfer Menu ................................................................ 61 D. Configure DHCP Server....................................................62 E. Enable/Disable DHCP ........................................................... 63 B. Enable/Disable DHCP Debug Messages ............................... 63 I. Configure DHCP Server Parameters....................................... 63 P. Configure DHCP Address Range Pool .................................. 63 C. Configure DHCP Client Entry............................................... 63 F. Display DHCP Configuration ................................................ 64 S. Display DHCP Server Statistics............................................. 64 A. Display DHCP Server Assigned Addresses .......................... 65 D. Display DHCP Entry Details................................................. 65 Lucent Technologies - vi - CellPipe™ IAD Series User’s Guide X. Delete a DHCP Client Entry.................................................. 66 Y. Delete a DHCP Assignment Entry ........................................ 66 N. Configure NAT ..................................................................66 B. Enable/Disable NAT Debug Messages.................................. 66 P. Enable/Disable NAT Translation by Port .............................. 66 T. Configure NAT TCP Timeout ............................................... 66 U. Configure NAT UDP Timeout .............................................. 66 R. Configure NAT Port Range ................................................... 67 N. Configure NAT Local Server Entry ...................................... 67 S. Display NAT Statistics........................................................... 67 C. Display NAT Connection Table ............................................ 68 D. Display NAT Connection Details.......................................... 68 O. Display NAT Local Server Table.......................................... 68 X. Delete IP Address from NAT Tables .................................... 68 Y. Delete NAT Local Server Entry ............................................ 69 T. Derived Timing ..................................................................69 1. Enable/Disable Derived Timing............................................. 69 2. Enable/Disable Derived Timing Debug Messages................. 69 Z. Diagnostics Menu ..............................................................70 P. POTS Diagnostics .................................................................. 70 R. Reset System....................................................................71 P. VoicePath Configure .........................................................71 V. Set Voice Gateway ................................................................ 71 J. Set Jitter Delay........................................................................ 71 D. Display Jitter Delay ............................................................... 72 S. Set Start Mode (Loop Start/Ground Start) ............................. 72 T. Set SLIC Control Mode ......................................................... 72 U. Set Compander Mode (u-Law, a-Law).................................. 72 O. Set On Hook Transmission Mode of Ground Start Lines ..... 73 M. Set Debug Mode ................................................................... 73 E. Configure Echo Cancellation Default Settings ...................... 73 G. Set Loop Gain........................................................................ 74 Lucent Technologies - vii - CellPipe™ IAD Series User’s Guide E. Toggle CMCP Debugging .................................................75 M. Manage MGCP/NCS Embedded Client ............................75 C. Configure MGCP/NCS parameters ....................................... 75 S. Display MGCP/NCS statistics ............................................... 75 D. Debug MGCP/NCS ............................................................... 75 R. Remove a connection............................................................. 76 A. Port Administration ............................................................... 76 P. Configure Default Packet Size ............................................... 76 E. CopperCom Call Control ...................................................77 S. Statistics ................................................................................. 77 C. Configure ............................................................................... 77 D. Debug Control ....................................................................... 77 E. Call Control Settings..........................................................79 A. Stats Display.......................................................................... 79 R. Ring Test................................................................................ 79 S. Display IAD State .................................................................. 80 T. Trace ...................................................................................... 80 V. Pick sound heard if insufficient WAN B/W to complete call ....................................................................... 81 U. Configure Tollbridge Voice Client......................................81 0. Set Client IP address............................................................... 81 1. Set Voice Gateway IP Address .............................................. 81 2. Print Current Configuration.................................................... 81 3. Debugging options ................................................................. 82 A. Application Menu...............................................................82 D. Display information Menu..................................................... 82 S. Set information Menu ............................................................ 84 A. AAL Type Menu ................................................................... 86 F. AAL2/LES Call Control ......................................................87 C. Configuration ......................................................................... 87 D. Debug Control ....................................................................... 88 S. Statistics ................................................................................. 90 Lucent Technologies - viii - CellPipe™ IAD Series User’s Guide 5. Administration.............................................................. 92 Security..................................................................................92 Changing the User ID................................................................. 93 Changing the Password .............................................................. 93 RADIUS server ......................................................................94 Changing the RADIUS server address ....................................... 95 Changing the RADIUS encryption secret .................................. 96 Displaying the RADIUS configuration ...................................... 96 Configuring SNMP .................................................................97 Enabling/disabling SNMP .......................................................... 98 Configuring the System Contact ................................................ 98 Configuring the System Name ................................................... 99 Configuring the System Location............................................. 100 Configuring the System Community........................................ 100 Configuring the SNMP Trap Host IP Address ......................... 101 Upgrading the system..........................................................102 Configuring the TFTP Server................................................... 102 Using TFTP .............................................................................. 103 Using Telnet ............................................................................. 104 Verifying the download............................................................ 105 Upgrading ACOS .................................................................106 Configuring the TFTP Server................................................... 106 Using TFTP .............................................................................. 106 Using Telnet ............................................................................. 108 Verifying the download............................................................ 108 6. WAN configuration......................................................110 Changing the Datalink Protocol ...........................................110 Configuring the Physical Interface .......................................111 Lucent Technologies - ix - CellPipe™ IAD Series User’s Guide Configuring the SDSL Interface............................................... 112 Configuring the T1 interface .................................................... 113 Switching from the T1 and E1 interfaces ................................. 116 Configuring the E1 interface .................................................... 116 Configuring the ADSL interface .............................................. 119 Quick Configuration .............................................................120 Configuring ATM PVCs........................................................122 Adding a PVC .......................................................................... 122 Modifying a PVC ..................................................................... 124 Deleting a PVC......................................................................... 125 Configuring ATM options .....................................................126 Configuring Payload Scrambling ............................................. 126 Configuring the F4 OAM Cell ................................................. 127 Sending OAM Loopback.......................................................... 127 Configuring Empty Cells.......................................................... 128 Configuring Frame Relay DLCIs ..........................................129 Adding a DLCI......................................................................... 129 Modifying a DLCI.................................................................... 131 Deleting a DLCI ....................................................................... 132 Configuring Frame Relay options ........................................133 Configuring fragmentation ....................................................... 133 Configuring the maintenance protocol ..................................... 134 Configuring the congestion parameters.................................... 136 Enabling/Disabling Copper Mountain CMCP ......................... 137 Configuring the voice path ...................................................138 Setting the jitter delay............................................................... 138 Setting the start mode ............................................................... 139 Setting the SLIC control mode................................................. 140 Setting the ground start on-hook transmission ......................... 141 Configuring Echo Cancellation ................................................ 142 Setting the loop gain................................................................. 144 Lucent Technologies -x- CellPipe™ IAD Series User’s Guide 7. Router configuration...................................................146 Configuring an IP address ...................................................146 Enabling RIP poisoned reverse ...........................................148 Enabling RIP poisoned reverse globally .................................. 148 Enabling RIP poisoned reverse by port .................................... 149 Setting the RIP version............................................................. 151 Adding a static route ............................................................152 Adding a default route..........................................................153 Disabling bridging ................................................................155 Disabling bridging globally...................................................... 155 Disabling bridging by port ....................................................... 156 Disabling STP......................................................................157 Disabling STP globally ............................................................ 157 Disabling STP by port .............................................................. 158 8. Bridge configuration...................................................160 Enabling Bridging.................................................................161 Enabling bridging globally....................................................... 161 Enabling bridging by port......................................................... 162 Setting the bridge aging timer .................................................. 163 Disabling RIP poisoned reverse ..........................................164 Disabling RIP poisoned reverse globally ................................. 164 Disabling RIP poisoned reverse by port................................... 165 Enabling STP.......................................................................166 Enabling STP globally.............................................................. 166 Enabling STP by port ............................................................... 167 Lucent Technologies - xi - CellPipe™ IAD Series User’s Guide 9. DHCP server configuration ........................................169 Enabling DHCP....................................................................169 Configuring the DHCP server parameters ...........................170 Configuring the DHCP address range pool..........................172 10. NAT configuration.......................................................174 Enabling NAT translation .....................................................175 Configuring the NAT local server entry ................................176 Configuring the NAT timeouts..............................................177 Configuring a NAT TCP timeout ............................................. 178 Configuring a NAT UDP timeout ............................................ 179 Configuring the NAT port range ...........................................180 11. Verification ..................................................................182 Power-up test ......................................................................182 Operational test ...................................................................182 Maintenance ........................................................................183 A. Menu hierarchy............................................................185 6. Configure LAN .................................................................197 7. Configure SNMP..............................................................197 8. Configure Login ...............................................................197 9. System Utilities ................................................................198 D. Configure DHCP Server..................................................199 N. Configure NAT ................................................................200 Lucent Technologies - xii - CellPipe™ IAD Series User’s Guide T. Derived Timing ................................................................200 Z. Diagnostics Menu ............................................................201 R. Reset System..................................................................201 P. VoicePath Configure .......................................................201 E. Toggle CMCP Debugging ...............................................202 M. Manage MGCP/NCS Embedded Client ..........................203 E. CopperCom Call Control .................................................203 E. Call Control Settings........................................................204 U. Configure Tollbridge Voice Client....................................204 A. Application Menu.............................................................205 F. AAL2/LES Call Control ....................................................205 B. CellPipe IAD specifications ........................................207 Network Interfaces...............................................................207 Bridging and Routing ...........................................................207 WAN Protocols ....................................................................208 Management and Configuration ..........................................208 Environmental......................................................................208 C. Connector pinouts ......................................................210 Console ...............................................................................210 10BaseT Connector.............................................................210 100BaseT Connector...........................................................211 ADSL/SDSL Connector .......................................................211 T1/E1 Connector..................................................................211 Lucent Technologies - xiii - CellPipe™ IAD Series User’s Guide D. IP Filtering ...................................................................212 E. Safeguards ..................................................................214 Regulatory Notices ..............................................................215 FCC Notice............................................................................... 215 Industry Canada Notice ............................................................ 217 Underwriters’ Laboratories’ Statement.................................218 Glossary ............................................................................219 Index ..................................................................................224 Lucent Technologies - xiv - CellPipe™ IAD Series User’s Guide ,QWURGXFWLRQ The Lucent Integrated Access Device (IAD) family of products provides a highly interoperable integrated voice and data service solution that is compatible with industry-leading DSLAM manufacturers. CellPipe IAD 4S/8S - provide voice services and highspeed Internet or corporate connectivity over SDSL lines [4 (IAD 4S) or 8 (IAD 8S) POTS ports]. Cellpipe IAD 8T – provides access to the preceding services over T1 leased lines (8 POTS ports). CellPipe IAD 4A - provides access to the preceding services over ADSL lines (4 (6100-4) or 8 (6108) POTS ports). The CellPipe IADs prioritize voice packets and dynamically allocate bandwidth between voice and data services. Organization of this guide This user guide contains the following chapters: Chapter 1, Introduction, introduces the different CellPipe IADs, describes customer support and hardware and software requirements, as well as the organization of this user guide. Chapter 2, CellPipe IAD basics, describes the hardware and software requirements, as well as the physical IAD. Chapter 3, Getting started, walks you through the procedures to connect and log on to the CellPipe IADs. It also provides information about the Menu interface, restarting the CellPipe IADs, auto log off, exiting the menu interface and verifying an IP address. Chapter 4, Menu interface, provides information on the CellPipe IAD menus, submenus, and commands. Chapter 5, Administration, provides information about the CellPipe IAD security, as well as how to configure the Simple Network Management Protocol (SNMP) and upgrade software. Chapter 6, WAN configuration, details how to configure the CellPipe IADs for voice and data operation. Chapter 7, Router configuration, describes how to configure the CellPipe IADs to function as a router. Lucent Technologies -1- CellPipe™ IAD Series User’s Guide Chapter 8, Bridge configuration, describes how to configure the CellPipe IADs to function as a bridge. Chapter 9, DHCP server configuration, walks you through the steps required to configure the Dynamic Host Configuration Protocol (DHCP) server. Chapter 10, NAT configuration, walks you through the steps required to configure the Network Address Translation (NAT). Chapter 11, Verification, describes how to verify that the CellPipe IADs operate properly after installation. It also covers maintenance, and how to display the current configuration. Appendix A, CellPipe IAD menu hierarchy, outlines the CellPipe IAD menu interface. Appendix B, CellPipe IAD specifications, lists all specifications for the CellPipe IADs. Appendix C, Connector pinouts, provides interface pinout information. Appendix D, IP Filtering, provides information about the IP filtering process. Appendix E, Safeguards, provides important regulatory information. Lucent Technologies -2- CellPipe™ IAD Series User’s Guide &HOO3LSH,$'EDVLFV This chapter describes the CellPipe IAD hardware and software requirements, as well as the physical IAD. Hardware and software requirements You must use a terminal emulation program, such as HyperTerminal or ProCommPlus, to configure the CellPipe IADs. Once you configure an IP address, you can also use Telnet to remotely administer the CellPipe IADs. For more information, see the Getting started chapter. Connectors The CellPipe IADs contain the following connectors: DC Power Input Connects the CellPipe IADs to an AC outlet of 90-250 volts via an external 18-Volt power supply. Console cable Connects the CellPipe IADs to a local PC, using a straight through 9-pin serial (DB9 RS 232) cable. You can then configure the CellPipe IADs using terminal emulation software. For more information on configuring the CellPipe IADs, see the Getting started chapter. Interfaces Available interfaces include the following: SDSL (CellPipe IAD 4S/8S) T1 (CellPipe IAD 8T) ADSL (CellPipe IAD 4A) 10/100BaseT Ethernet 4 or 8 POTS Ports Lucent Technologies -3- CellPipe™ IAD Series User’s Guide Power/status Indicators The front panel of the CellPipe IADs contains the following LEDs: POWER – indicates whether the power is on. LAN LINK – illuminates when there is a proper connection on the Ethernet port. LAN ACT – flashes when there is activity on the Ethernet port. WAN LINK – illuminates when there is a proper connection on the DSL WAN port. VOICE – illuminates when there is activity on the voice ports. These indicators illuminate when the CellPipe IADs receive power, connect to a LAN or a SDSL/ADSL/T1 link. Lucent Technologies -4- CellPipe™ IAD Series User’s Guide *HWWLQJVWDUWHG This chapter walks you through the procedures to connect and log on to the CellPipe IADs. It also provides information about the menu interface, restarting the CellPipe IADs, auto log off, exiting the menu interface, and verifying an IP address. For more information on the menus, submenus and commands in this chapter, see the Menu interface chapter. Connecting To connect a CellPipe IAD to a PC: 1. Insert the male connector of the DB9 console cable into the CONSOLE port. 2. Insert the female connector of the DB9 console cable into a 9-pin serial port on your PC (COM1 or COM2). 3. Plug the power supply into the CellPipe IAD, and then into a wall outlet or uninterruptible power supply (UPS). Once connected, you need to log on to the CellPipe IAD. Connecting two Ethernet devices If you want to connect two Ethernet devices together, the cable that you use depends on whether or not you are using a hub: Using a hub – straight through cable Directly (no hub) – cross-over Ethernet cable Lucent Technologies -5- CellPipe™ IAD Series User’s Guide Logging on There are two ways that you can log on to the CellPipe IADs: A terminal emulation program through the console port. A Telnet program through the Ethernet port. Using a terminal emulation program To use a terminal emulation program to log on to a CellPipe IAD: 1. Open the terminal emulation program. 2. Select the name, icon, and COM port for the CellPipe IAD connection. 3. Type or select the following settings, and then save your changes. Bits per second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow control: None Emulation: ANSI Font: Terminal For more information, see your terminal emulation program documentation. 4. Press ENTER. The log on message displays. Enter Login ID > 5. Type your User ID, and press ENTER. The password message displays. Enter Password > The following are the default User IDs and passwords: Access Level User Network Administrator Supervisor User ID <Enter> NetMan Supervisor Password <Enter> <Enter> supervisor For more information, see the Administration chapter. Lucent Technologies -6- CellPipe™ IAD Series User’s Guide 6. Type your password, and the press ENTER. The Main Menu displays. ***************************************** * Main Menu * ***************************************** 1. Reports Menu 2. Configure IP Router 3. Configure Bridge 5. Configure WAN 6. Configure LAN 7. Configure SNMP 8. Configure Login 9. System Utilities D. Configure DHCP Server N. Configure NAT T. Derived Timing Z. Diagnostics Menu R. Reset System P. VoicePath Configure For more information on the menus, submenus, and commands on the Main Menu, see the Menu interface chapter. Using a Telnet program You must set an IP address for the Ethernet port before you can use a Telnet program to access the CellPipe IADs. If you configure a RADIUS server, you must use a RADIUSauthenticated User ID/password for telnet access. If the RADIUS server goes down, telnet access will not work. Lucent Technologies -7- CellPipe™ IAD Series User’s Guide Configuring a port IP address To configure a port IP address: 1. On the Main Menu, select Configure IP Router. The Router Configuration Menu displays. ***************************************** * Router Configuration Menu * ***************************************** C. Configure Port IP Address U. Unconfigure Port IP Address S. Add/Remove a Static Route R. Enable/Disable RIP V. Configure RIP Version by Port P. Configure RIP Poisoned Reverse by Port N. Configure DNS Client H. Configure DHCP Client L. Configure DHCP Relay T. Configure Telnet Server Port F. Configure IP Filtering D. Display Route Table 2. Select Configure Port IP Address. The following instructions display on-screen: Available Interfaces: 1. G7070 ADSL ATU-R 1. T1 1. SDSL 2. 10/100BaseT Ethernet 0. (Abort) Selection: Interfaces may not display, depending on the IAD in use. 3. Type the number of the port for which you want to configure an IP address. The following message (or one similar) displays: Lucent Technologies -8- CellPipe™ IAD Series User’s Guide IP interfaces on port 1: ID IPAddr IPMask Priority 0 255.255.255.0 255.255.255.0 NORMAL Enter connection to configure: 4. Type the ID number of the connection that you want to configure (range = 0-7), and then press ENTER. 5. Type the new IP address, or press ENTER to select the current IP address. The following instructions display on-screen: Current subnet mask = 0.0.0.0 Enter new subnet mask for this interface: 6. Type the new subnet mask address, or press ENTER to select the current subnet mask. The following instructions display on-screen: Select priority Normal/High [N/H] (N): 7. Do one of the following, and then type Y: To give the interface high priority, type H. To give the interface normal priority, type N. 8. Repeat steps 1-6 for each port for which you want to configure an IP address. You must restart the CellPipe IADs for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. You can now run the Telnet program. Running the Telnet program To use a Telnet program to log on to a CellPipe IAD: 1. Open the Telnet program. 2. Type the IP address of the port that you configured in steps 1-6, press CONNECT, and then press any key. The log on message displays. Enter Login ID > 3. Type your User ID, and press ENTER. The following are the default User IDs and passwords: Access Level User Network Administrator Supervisor Lucent Technologies -9- User ID <Enter> NetMan Supervisor Password <Enter> <Enter> supervisor CellPipe™ IAD Series User’s Guide For more information, see the Administration chapter. The password message displays. Enter Password > 4. Type your password, and the press ENTER. The Main Menu displays. ***************************************** * Main Menu * ***************************************** 1. Reports Menu 2. Configure IP Router 3. Configure Bridge 5. Configure WAN 6. Configure LAN 7. Configure SNMP 8. Configure Login 9. System Utilities D. Configure DHCP Server N. Configure NAT T. Derived Timing Z. Diagnostics Menu R. Reset System P. VoicePath Configure For more information on the menus, submenus and commands on the Main Menu, see the Menu interface chapter. The User ID and password transmit as clear text, which can be captured by unauthorized individuals. If you are concerned with network security, you may not want to use a Telnet program to configure the CellPipe IADs. Menu interface The CellPipe IADs provide an ASCII-based menu interface for system configuration and monitoring. Menus, submenus, and commands may not display, depending on the options configured or the access level that you use to log on: User NetMan Supervisor Lucent Technologies - 10 - CellPipe™ IAD Series User’s Guide For more information on the access levels, see the Administration chapter. For more information on the menus, submenus and commands on the Main Menu, see the Menu interface chapter. For a hierarchical overview of the Main menu and its submenus and commands, see the CellPipe IAD menu hierarchy appendix. Default values The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. For example, if you press ENTER when the following message displays, Enter a new subnet mask for this interface: (255.255.255.0) -) the CellPipe IADs set 255.255.255.0 as the subnet mask value. Restarting Any time you use the Menu interface to make changes or change any of the physical characteristics of the CellPipe IADs, such as the MAC address of the Ethernet port, you must restart the CellPipe IADs for the new settings to take effect. To restart the CellPipe IADs: 1. On the Main Menu, select Reset System. The following instructions display on-screen: Press R to Reset now-> 2. Type R. 3. Type your User ID, and then type your password. For more information, see the Logging on section earlier in this chapter. You can also unplug and then plug in the CellPipe IADs to restart the system using the new settings. Lucent Technologies - 11 - CellPipe™ IAD Series User’s Guide Auto Log off After three minutes of inactivity, the CellPipe IADs automatically log off. To change this value, you can use the Configure_Console_Timeout command on the System Utilities menu. For more information, see the Menu_interface chapter. To restart, you must log on to the system again. This does not affect routing functionality - network traffic continues to process. For more information, see the Logging on section earlier in this chapter. Exiting To exit the menu interface: On the Main Menu, press ESC. Verifying an IP address When running the CellPipe IADs, there are several different IP addresses: One for a computer running Windows 95/98/Me/2000. One or more for the CellPipe IADs. A computer running Windows 95/98/Me/2000 To verify the IP address of your computer: 1. Click the Start button, point to Settings, and then click Control Panel. 2. In Control Panel, double-click the Network icon, and then click the Configuration tab. 3. In The following network components are installed list, click TCP/IP, and then click Properties. 4. Click the IP Address tab, and note the IP address that displays. You can also run the winipcfg command at the command prompt to verify the IP address of your computer. Lucent Technologies - 12 - CellPipe™ IAD Series User’s Guide The CellPipe IADs To verify the IP address of the CellPipe IADs: 1. On the Main Menu, select Reports Menu. The Reports Menu displays. ***************************************** * Reports Menu * ***************************************** C. Display Current Configuration N. Display Network Statistics I. Display Interface Statistics M. Display Media Statistics R. Display Route Table A. Display ARP Table B. Display Bridge Forwarding Database S. Display Bridge Status P. Display PPP Authorization Entries U. Display System Uptime O. Display Memory Statistic 2. Select Display Current Configuration. 3. Note the IP addresses for the Ethernet and ADSL/T1 /SDSL Interface. Lucent Technologies - 13 - CellPipe™ IAD Series User’s Guide 0HQXLQWHUIDFH This chapter provides information on the CellPipe IAD menus, submenus, and commands. For an outline of the CellPipe IAD menu structure, see the CellPipe IAD menu hierarchy appendix. Select a menu, submenu, or command to display its options. To return to the previous menu or to exit the program from the Main Menu, press ESC. Menus, submenus, and commands that display on the Main Menu depend on the access level that you use to log on or the voice path options that you configure. Main Menu The Main Menu contains the following submenus: 1. Reports Menu 2. Configure IP Router 3. Configure Bridge 5. Configure WAN 6. Configure LAN 7. Configure SNMP 8. Configure Login 9. System Utilities D. Configure DHCP Server N. Configure NAT T. Derived Timing Z. Diagnostics Menu R. Reset System P. VoicePath Configure E. Toggle CMCP Debugging M. Manage MGCP/NCS Embedded Client E. CopperCom Call Control E. Call Control Settings U. Configure Tollbridge Voice Client A. Application Menu E. AAL2/LES Call Control Lucent Technologies - 14 - CellPipe™ IAD Series User’s Guide 1. Reports Menu The Reports Menu contains the following submenus and commands. C. Display Current Configuration Displays the following configuration settings and information about the installed Interfaces. Information may not display, depending on the Interfaces installed and the unit selected. • Software version – version of LUIAD. • Serial Number • ICTRL - For manufacturing use only. • I - Cache – instruction cache; enabled or disabled. • D - Cache – data cache; enabled or disabled. • SYPCR register SWRI bit - generate NMI (debug) or generate hard reset (normal). • Routing Information Protocol (RIP) – enabled or disabled globally. • Bridging – enabled or disabled globally. • Bridge Database Aging Time – 1-3600 seconds (default = 300 seconds). • Spanning Tree - enabled or disabled globally. • Spanning Tree bridge priority - 1-65,535 (default = 32,768). • Spanning Tree hello time - 1-10 seconds (default = 2 seconds). • Spanning Tree max age - 6-40 seconds (default = 20 seconds). • Spanning Tree forward delay - 4-30 seconds (default = 15 seconds). • Simple Network Management Protocol (SNMP) enabled or disabled. • SNMP System Contact - user-defined (maximum = 39 alphanumeric characters). • SNMP System Name - user-defined (maximum = 39 alphanumeric characters). • SNMP System Location - user-defined (maximum = 39 alphanumeric characters). Lucent Technologies - 15 - CellPipe™ IAD Series User’s Guide • • • • • • • • Lucent Technologies SNMP Community - name must match the SNMP host (maximum = 39 alphanumeric characters); If SNMP is enabled and the SNMP Community Name is null, SNMP goes into read-only mode. SNMP Trap Host IP Address - IP address of the SNMP trap host. Telnet Server Port - port number of the Telnet server. DNS Server IP Address – IP address of the DNS Server. DNS Server Timeout Application Information - loaded program files. Support File Information - loaded support files. Interface type – enabled or disabled. o Admin state - enabled or disabled. o PHY state - ONLINE or OFFLINE. o DataLink Protocol - Totally Transparent, Raw HDLC, Cisco compatible HDLC, IP-Plus compatible HDLC, PPP (over Raw HDLC), ATM or Frame Relay. o Firmware Version o Mode - Customer Premises Equipment (CPE) or Central Office (CO). o Line Rate - Auto, Fixed, 1152 Kbps, 768 Kbps, 384 Kbps, 192 Kbps, 2320 Kbps or manually set. o Frame Relay Management o RIP - enabled or disabled. o Poisoned Reverse - enabled or disabled. o Dynamic Host Configuration Protocol (DHCP) Client – enabled or disabled. o Bridging - enabled or disabled. o Spanning Tree - enabled or disabled. o Port Priority - 0-255 (default = 128). o Path Cost - 1-65,535 (default = 32,768). o T1 Frame Mode - ESF or D4. o Binary 8 Zero Substitution (B8ZS) – enabled or disabled. o Line Build Out - 0 to 133 Feet (0 dB0, 133 to 266 Feet, 266 to 399 Feet, 399 to 533 Feet, 533 to 655 Feet, -7.5 dB, -15 dB or -22.5 dB (T1 module). o Tx Clock Source - external or internal (T1 module). o Tx Channels Enabled - (T1 module). - 16 - CellPipe™ IAD Series User’s Guide o o o o o o o o o o o o o o o o o o o o Rx Channels Enabled - (T1 module). HDB3 coding - enabled or disabled; (T1 module). Sa4 Bit - set or cleared; (T1 module). Sa5 Bit - set or cleared; (T1 module). Sa6 Bit - set or cleared; (T1 module). Sa7 Bit - set or cleared; (T1 module). Sa8 Bit - set or cleared; (T1 module). Rcv Clk Source – internal or external. PPP Auth Type – None, PAP Client, PAP Server, CHAP Client or CHAP Server. Userid – PAP User ID. Password – PPP password. Peer Name DLCI – RAW (No Encapsulation), Proprietary Voice DLCI, RFC 1490 or ATM RFC 1483 (Tunneling). VPI/VCI – RAW (AAL5), RAW (AAL0), Proprietary Voice, RFC 1483 (using VC Muxing), RFC 1483 (with LLC Encapsulation), RFC 2364 (PPPoATM with LLC Encapsulation) or RFC 2364 (PPPoATM using VC Muxing). ID – host ID. IPAddr - IP Addresses for the ID (maximum = 8). IPMask - number of bits reserved for the host ID (maximum = 8). Priority – normal or high. Ethernet address – Ethernet for the Interface. Full duplex – enabled or disabled (Ethernet). N. Display Network Statistics Displays the Network Statistics submenu, which contains commands to display the following statistical information about the packets handled by the Ethernet and WAN ports: C. Display ICMP Statistics I. Display IP Statistics T. Display TCP Statistics U. Display UDP Statistics Lucent Technologies - 17 - CellPipe™ IAD Series User’s Guide Z. Clear a Network Statistic Displays the Clear Statistics submenu, which contains the following commands: C. Clear ICMP Statistics I. Clear IP Statistics T. Clear TCP Statistics U. Clear UDP Statistics Select your choice. I. Display Interface Statistics Displays the following statistical information about the total packets handled between layer 2 and layer 3 on a per port basis. Type the number of the Interface, the number of the port, and then choose a command from the Interface Statistics submenu. Commands may not display, depending on the modules installed. A. Display ARP Statistics I. Display Interface Statistics B. Display Bridge Statistics** D. Display DLCI Statistics A. Display ATM PVC Statistics Z. Clear ATM PVC Statistics Z. Clear a Statistic Displays the Clear Statistics submenu, which contains the following commands: A. Clear ARP Statistics I. Clear Interface Statistics B. Clear Bridge Statistics D. Clear Frame Relay DLCI Statistics Select your choice. ** You must enable bridging for this option to display. For more information on enabling bridging, see the Bridge_configuration chapter. M. Display Media Statistics Displays the following statistical information about the total packets handled (Layer 2) on a per port basis. Type the number of the Interface, and then choose a command from the Media Statistics submenu. Lucent Technologies - 18 - CellPipe™ IAD Series User’s Guide Commands may not display, depending on the protocols configured. F. Display Frame Relay Statistics S. Display Serial Statistics Z. Clear a Statistic Displays the Clear Statistics submenu, which contains the following commands: F. Clear Frame Relay DLCI Statistics S. Clear Serial Statistics Select your choice. 1. Display ATM Statistics Z. Clear ATM Statistics 2. Display ATM Statistics F. Display Frame Relay Statistics S. Display Serial Statistics Z. Clear a Statistic Displays the Clear Statistics submenu, which contains the following commands: 1. Clear G2237 ADSL Statistics 2. Clear ATM Statistics F. Clear Frame Relay DLCI Statistics S. Clear Serial Statistics Select your choice. 1. Display G7070 ADSL Statistics 2. Display ATM Statistics F. Display Frame Relay Statistics S. Display Serial Statistics Z. Clear a Statistic Displays the Clear Statistics submenu, which contains the following commands: 1. Clear G7070 ADSL Statistics 2. Clear ATM Statistics F. Clear Frame Relay DLCI Statistics S. Clear Serial Statistics Select your choice. 1. Display ENET Statistics Z. Clear ENET Statistics 1. Display POTS Statistics Z. Clear POTS Statistics Select your choice. Lucent Technologies - 19 - CellPipe™ IAD Series User’s Guide R. Display Route Table Displays the following information about statically configured routes and dynamically learned ones: • NETWORK ADDRESS - destination address. • NETMASK - IP subnet mask; number of bits reserved for the host ID. • GATEWAY ADDRESS - IP address of packets sent to destination. • Interface - IP address of outgoing interface. • Metric - number of hops (routers) required to reach the specified gateway. • Type – static or dynamic. A. Display ARP Table The Address Resolution Protocol (ARP) obtains the Ethernet MAC address for a known IP address. Displays the following information about mappings between Ethernet Media Access Control (MAC) addresses (hardware addresses) and IP addresses: • IP ADDRESS - IP address that corresponds to the MAC address. • ETHERNET ADDRESS - Ethernet address of the device; assigned by the manufacturer. • Interface - the interface for the Ethernet address. B. Display Bridge forwarding database Displays the following information about mappings between Ethernet addresses and devices connected to the LAN: • ETHERNET ADDRESS - Ethernet address of the device; assigned by the manufacturer. • Interface - the interface for the Ethernet address. • PORT - the port for the Ethernet interface. • TIMER - number of seconds until this entry deletes from the database. The time counts down from the Bridge database aging time value, in one-second intervals; at zero, the entry deletes from the database. You must enable bridging for this table to display. For more information on enabling bridging, see the Bridge_configuration chapter. Lucent Technologies - 20 - CellPipe™ IAD Series User’s Guide S. Display Bridge status Displays the following information about bridging: • Interface - interface for the active slot for bridging. • PORT - port for the preceding interface. • Spanning Tree Protocol (STP) - enabled or disabled. • STATE - Spanning tree state: disabled, blocking, listening, learning or forwarding. • ROOT - root port for the bridge: yes or no. • DESIGNATED - designated port for the bridge: yes or no. • TIMERS - current values of the spanning state timer (first value) and the hello timer (second value). The spanning state timer value is for listening or learning states and counts down from the forward delay time to zero. The hello timer value is valid only if the active port is the Root Bridge of the network. It counts down from the hello time to zero. • Root priority - priority of the root bridge on the network. • Id - Ethernet MAC address of the root bridge on the network. P. Display PPP Authorization Entries Displays the following information about PPP authorization entries: • Authorization type - None, Password Authentication Protocol (PAP) Client, PAP Server, Challenge Handshake Authentication Protocol (CHAP) Client or CHAP Server. • Slot #/Interface #/Port # - active slot for the PPP interface. • Userid/Password/Peer Name – values for the PPP interface. U. Display System Uptime Displays the amount of time elapsed during the active session. Lucent Technologies - 21 - CellPipe™ IAD Series User’s Guide O. Display Memory Statistic Displays the Memory Statistic Menu, which contains the following commands: M. Display System Memory Statistic Displays the following information about the system memory: • Total Memory Size • Total Allocated Memory • Total Free Memory • Kernel Memory Size • • • Kernel Memory Allocated • Allocated Blocks • Largest Allocated Block Size • Highest Memory Used Kernel Free Memory • Free Blocks • Largest Free Block Size Reserved Area Size T. Display Kernel Tasks Memory Statistic Displays the following information about the Kernel tasks: Lucent Technologies • TASK 0 Allocated Size • TASK 1 Allocated Size • TASK 2 Allocated Size • TASK 3 Allocated Size • TASK 4 Allocated Size • TASK 5 Allocated Size • TASK 6 Allocated Size • TASK 7 Allocated Size • TASK 8 Allocated Size • TASK 9 Allocated Size • TASK 10 Allocated Size • TASK 11 Allocated Size - 22 - CellPipe™ IAD Series User’s Guide Lucent Technologies • TASK 12 Allocated Size • TASK 13 Allocated Size • TASK 14 Allocated Size: - 23 - CellPipe™ IAD Series User’s Guide 2. Configure IP Router The Router Configuration Menu contains the following submenus and commands. 5RXWLQJ Main Menu Configure RIP version by port All interfaces configured with IP? Enable bridging interface per port Define IP for each interface per port Enable global bridging Using RIP? Using default route? Enable RIP globally Add default route to routing table Add static route to routing table End End End You must restart the CellPipe IADs for any changes to take effect. For more information, see the CellPipe IAD basics chapter. Lucent Technologies - 24 - CellPipe™ IAD Series User’s Guide C. Configure Port IP Address Sets the IP address and subnet mask for the selected interface. Type the number of the Interface, the number of the port or connection to configure, and then enter the following: • New IP address • New subnet mask • Priority The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. U. Unconfigure Port IP Address Deletes the IP address of the selected interface. Type the number of the port to unconfigure, confirm, and then press ENTER. S. Add/Remove a Static Route Displays the Router Modification Menu, which contains the following commands: A. Add a Static Route Creates a static route and adds it to the Route Table. Type the following information for the route that you want to add, and then press ENTER: • Destination (IP) address • Network mask • Gateway The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. R. Remove a Route Deletes a static route from the Route Table. Type the IP address of the route to remove, and then press ENTER. F. Add/Change Default Route Creates or changes the default static route, and then adds it to the Route Table. Type the Gateway address for the default route, and then press ENTER. Lucent Technologies - 25 - CellPipe™ IAD Series User’s Guide T. Remove the Default Route Deletes the default static route from the Route Table. Type the IP address to remove, and then press ENTER. D. Display Route Table Displays the following information about statically configured routes and dynamically learned ones: • NETWORK ADDRESS - destination address. • NETMASK - IP subnet mask; number of bits reserved for the host ID. • GATEWAY ADDRESS - IP address of packets sent to destination. • Interface - IP address of outgoing interface. • Metric - number of hops (routers) required to reach the specified gateway. • Type – static or dynamic. R. Enable/Disable RIP Enables and disables the Routing Information Protocol (RIP). RIP sends routing information from one router to adjacent routers, dynamically learning network topology. When you enable RIP, the CellPipe IADs store sent routing information in the Route Table. For more information on the Route Table, see the Reports Menu section earlier in this chapter. V. Configure RIP Version by Port Sets the RIP version for the selected port. Type the number of the Interface, the port number, and then select one of the following RIP Versions: 0. Disabled 1. Version 1 Broadcast 2. Version 2 Broadcast 3. Version 2 Multicast P. Configure RIP Poisoned Reverse by Port Enables and disables RIP Poisoned Reverse for the selected interface. Lucent Technologies - 26 - CellPipe™ IAD Series User’s Guide When you enable RIP Poisoned Reverse, the CellPipe IADs send routing data to other adjacent routers and dynamically learn the associated network topology. Type the number of the Interface, and then enable or disable. N. Configure DNS Client Displays the DNS Client Menu, which contains the following commands to configure the Domain Name Server (DNS) client: A. Set DNS Server IP Address Sets the IP address of the DNS Server. Type the DNS Server IP address and then press ENTER. T. Set DNS Server Timeout Sets the DNS Server Timeout, a value between 5 - 20 seconds (default = 5 seconds). Type the DNS Server Timeout value, and then press ENTER. S. Display DNS Cache and Statistics Displays information about the data in the DNS cache. H. Configure DHCP Client Enables and disables the Dynamic Host Configuration Protocol (DHCP) client for the selected Interface. Type the number of the Interface, the number of the port, and then enable or disable. L. Configure DHCP Relay Displays the DHCP Relay Menu, which contains the following commands to configure the DHCP Relay: E. Enable/Disable DHCP Relay Enables and disables the DHCP Relay. When you enable the DHCP Relay, you must also enter a new DHCP server IP address. Type the DHCP Server IP address, and then press ENTER. The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. C. Configure DHCP Relay Sets the DHCP server IP address. Type the DHCP Server IP address, and then press ENTER. The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Lucent Technologies - 27 - CellPipe™ IAD Series User’s Guide S. Display DHCP Relay Statistics Displays the following information about the DHCP Relay: • DHCP client requests forwarded to DHCP server • DHCP client requests dropped • Server responses forwarded to DHCP clients • Server responses dropped • Unknown server responses • Server requests timed out T. Configure Telnet Server Port Sets the port for the Telnet Server (default = 23). Type the number of the port, and then press ENTER. The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. F. Configure IP Filtering Displays the IP Filtering Configuration Menu, which contains the following submenu and commands to configure IP filtering. For more information, see the IP Filtering appendix. P. Choose port for IP filtering Sets the port on which to use IP filtering. Type the number of the interface, the number of the port (if applicable), and then press ENTER. F. Globally enable/disable input or output filters Enables and disables the input and output filters for all installed interfaces. You must globally enable the filters for the associated filtering to work. Follow the on-screen instructions to enable or disable both the input and output filters globally. Lucent Technologies - 28 - CellPipe™ IAD Series User’s Guide T. Toggle input or output type filters to view/edit Switches between the input and output filter types. The filter type that you set here determines what displays when you select any of the following commands: • Display all filters of the chosen type • Insert a new or buffered filter of the chosen type • Append a new or buffered filter to the end of the list • Edit filter of the chosen type • Copy filter operations menu • Delete one filter of the chosen type • Delete all filters of the chosen type D. Display all filters of the chosen type Displays all filters of the type set with the Toggle input or output type filters to view/edit command. I. Insert a new or buffered filter of the chosen type Adds a new filter of the type set with the Toggle input or output type filters to view/edit command anywhere in the list that displays when you select Display all filters of the chosen type. Type the number of the filter before which you want to insert the new filter, and then follow the on-screen messages to enter the following information: • Filter state – Idle or Active • Filter action – Pass or Discard • Filter protocol – IP, ICMP, IGMP, TCP, UDP • Filter Source IP Low Address • Filter Source IP High Address • Filter Source Port Low • Filter Source Port High • Filter Destination IP Low Address • Filter Destination IP High Address • Filter Destination Port Low • Filter Destination Port High The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Lucent Technologies - 29 - CellPipe™ IAD Series User’s Guide A. Append a new or buffered filter to the end of the list Adds a new filter of the type set with the Toggle input or output type filters to view/edit command to the end of list that displays when you select Display all filters of the chosen type. Type Y, and then follow the on-screen messages to enter the following information: • Filter state – Idle or Active • Filter action – Pass or Discard • Filter protocol – IP, ICMP, IGMP, TCP, UDP • Filter Source IP Low Address • Filter Source IP High Address • Filter Source Port Low • Filter Source Port High • Filter Destination IP Low Address • Filter Destination IP High Address • Filter Destination Port Low • Filter Destination Port High The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. E. Edit filter of the chosen type Displays all filters of the type that you set with the Toggle input or output type filters to view/edit command that you can edit. Type the number of the filter to edit, and then follow the on-screen messages to enter the following information: • Filter state – Idle or Active • Filter action – Pass or Discard • Filter protocol – IP, ICMP, IGMP, TCP, UDP • Filter Source IP Low Address • Filter Source IP High Address • Filter Source Port Low – TCP or UDP packets only • Filter Source Port High - TCP or UDP packets only • Filter Destination IP Low Address • Filter Destination IP High Address • Filter Destination Port Low • Filter Destination Port High Lucent Technologies - 30 - CellPipe™ IAD Series User’s Guide The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. C. Copy filter operations menu Displays the IP Filter Copy to Buffer Menu, which contains the following commands for all filters of the type that you set with the Toggle input or output type filters to view/edit command. C. Copy a filter of the chosen type to the buffer Copies the filter that you select to the buffer. Type the number of the filter to copy, and then press ENTER. D. Display the filter in the copy buffer Displays the following information about the filter in the copy buffer: • num – number of the filter • state – Idle or Active • action – Pass or Discard • srcLwP - Filter Source Port Low – TCP or UDP packets only • srcHiP - Filter Source Port High - TCP or UDP packets only • source.ip.addr.low - Filter Destination IP Low Address • source.ip.addr.high - Filter Source IP High Address • proto - Filter protocol – IP, ICMP, IGMP, TCP, UDP • • • • mask – ICMP or TCP only dstLwP - Filter Destination Port Low dstHiP - Filter Destination Port High dest.ip.addr.low - Filter Destination IP Low Address • dest.ip.addr.high - Filter Destination IP High Address E. Edit the filter in the copy buffer Edits the filter in the copy buffer. Follow the on-screen messages to enter the following information: • Filter state – Idle or Active • Filter action – Pass or Discard Lucent Technologies - 31 - CellPipe™ IAD Series User’s Guide • Filter protocol – IP, ICMP, IGMP, TCP, UDP • Filter Source IP Low Address • Filter Source IP High Address • Filter Source Port Low – TCP or UDP packets only • Filter Source Port High - TCP or UDP packets only • Filter Destination IP Low Address • Filter Destination IP High Address • Filter Destination Port Low • Filter Destination Port High The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. X. Deletes the filter from the copy buffer Deletes the filter from the copy buffer. X. Delete one filter of the chosen type Deletes the filter that you select from the copy buffer. Type the number of the filter to delete and then press ENTER. Z. Delete all filters of the chosen type Deletes all filters in the copy buffer. S. Show IP filtering statistics Displays the total number of input and output data packets filtered. Y. Clear IP filtering statistics Deletes all data from the Show IP filtering statistics command. D. Display Route Table Displays the following information about statically configured routes and dynamically learned ones: • NETWORK ADDRESS - destination address. • NETMASK - IP subnet mask; number of bits reserved for the host ID. • GATEWAY ADDRESS - IP address of packets sent to destination. • Interface - IP address of outgoing interface. Lucent Technologies - 32 - CellPipe™ IAD Series User’s Guide • • Lucent Technologies Metric - number of hops (routers) required to reach the specified gateway. Type – static or dynamic. - 33 - CellPipe™ IAD Series User’s Guide 3. Configure Bridge Displays the Bridge Configuration Menu, which contains the following submenu and commands. %ULGJLQJ Main Menu Enable bridging by port Enable bridging globally Enable spanning tree by port Using spanning tree? Enable spanning tree globally Assigning bridge priority? Define bridge priority Lucent Technologies Define root bridge Assigning root bridge? End End - 34 - CellPipe™ IAD Series User’s Guide Your settings display in the Display Current Configuration command in the Reports Menu. For more information, see the Reports Menu section earlier in this chapter. You must enable bridging both globally and by port number, and then restart the CellPipe IADs for any changes to take effect. For more information on restarting the CellPipe IADs, see the CellPipe IAD basics chapter. G. Enable/Disable Bridging Globally Enables and disables bridging for all installed interfaces. P. Enable/Disable Bridging by Port Enables and disables bridging by port. Type the number of the Interface to enable or disable, and then press ENTER. A. Configure Bridge Aging Timer Sets the bridge database aging time, a value between 1-3,600 seconds (default = 300 seconds). Type the bridge aging time value, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. The time counts down in one-second intervals; at zero, the entry deletes from the database. T. Enable/Disable Spanning Tree Globally Enables and disables the Spanning Tree protocol for all installed interfaces. O. Enable/Disable Spanning Tree by Port Enables and disables the Spanning Tree protocol for the selected Interface. Type the number of the Interface, and then select enable or disable. R. Configure Spanning Tree Bridge Priority Sets the Spanning Tree bridge priority, a value between 165,565 (default = 32,768). Type the Spanning Tree bridge priority value, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Lucent Technologies - 35 - CellPipe™ IAD Series User’s Guide The Spanning Tree algorithm selects the bridge with the lowest priority on the network as the Root Bridge. Q. Configure Spanning Tree Port Priority Sets the Spanning Tree priority by port, a value between 0255 (default = 128). The lower the value, the higher the priority. Type the number of the Interface to configure, the port priority value, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. The spanning tree algorithm uses the spanning tree bridge priority to determine which bridge to use as the Ethernet LAN destination when two or more bridges are bridging between the same LAN. H. Configure Spanning Tree Hello Time Sets the Spanning Tree hello time, a value between 1-10 seconds (default = 2 seconds). Type the hello time value, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. S. Configure Spanning Tree Max Age Sets the Spanning Tree max age, a value between 6-40 seconds (default = 20 seconds). Type the max age value, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. F. Configure Spanning Tree Forward Delay Sets the Spanning Tree forward delay, a value between 4-30 seconds (default = 15 seconds). Type the forward delay value, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Lucent Technologies - 36 - CellPipe™ IAD Series User’s Guide C. Configure Spanning Tree Path Cost Sets the Spanning Tree path cost, a value between 1- 65,535 (default = 32,768). Type the number of the Interface to configure, type the path cost value, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. When there are multiple paths to the Root Bridge, the Spanning Tree algorithm selects the port with the lowest total path cost as the route port. D. Delete Bridge Forwarding Database Entry Deletes an Ethernet address from the bridge forwarding database. Type the Ethernet address to delete, and then press ENTER. Lucent Technologies - 37 - CellPipe™ IAD Series User’s Guide 5. Configure WAN Displays the WAN Configuration Menu, which contains the following submenu and commands. Commands may not display, depending on the datalink protocol that you select and the Interface installed. 6'6/:$1 FRQILJXUDWLRQ SDSL Module Changing factory configuration? Select quick configuration ATM? Define PVCs ATM? Frame Relay? Configure ATM options Define PVCs Frame Relay? Define DLCIs Configure ATM options Define DLCIs End Set maintenance protocol End Set maintenance protocol End End Lucent Technologies - 38 - CellPipe™ IAD Series User’s Guide 0. Quick Configuration (CellPipe IAD 4S/8S) Displays the Quick Configuration submenu, which contains the following commands to quickly configure the CellPipe IAD 4S/8S. 1. Lucent Stinger (Conexant Autobaud, Payload Scrambling) 2. Nokia (Auto Cycle) 3. Copper Mountain (Auto Sense) 4. Paradyne Scrambling) (Framed 784Kbps, Payload 5. AccessLan CPE 6. Nortel IMAS 7. ATM (Unframed, 1152Kpbs fixed) 8. Frame Relay (784Kpbs fixed) Select your choice. Restart the CellPipe IADs for any changes to take effect. For more information on restarting the CellPipe IADs, see the CellPipe IAD basics chapter. 1. Configure Datalink Protocol Displays the WAN Datalink Protocol Configuration Menu, which contains the following commands to set the data link control protocol for the active interface. Commands may not display, depending on the IAD in use. 1. Totally Transparent 2. Raw HDLC 3. Cisco compatible HDLC 4. IP-Plus compatible HDLC 5. PPP (over Raw HDLC) 6. ATM 7. Frame Relay Select your choice. The IAD automatically restarts. Your settings display in the Display Current Configuration command in the Reports Menu. For more information, see the Reports Menu section earlier in this chapter. Lucent Technologies - 39 - CellPipe™ IAD Series User’s Guide 2. Configure Physical Interface Configure Physical Interface submenus and commands may not display, depending on the Interface that you select. ADSL Mode (CellPipe IAD 4A) Displays G7070 ADSL ATU-R Configuration submenu, which contains the following commands to set the ADSL standard and enable/disable debugging messages. The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. 1. G7070ConfigStandard Displays the ADSL Standard to use for Startup submenu, which contains the following commands to set the ADSL standard. 1. T1.413 2. G.LITE 3. G.DMT 4. Alcatel 1.4 5. Multi-Mode 6. ADI 7. ALCATEL Select your choice. D. Enable/Disable ADSL Debug Messages Enables and disables the display of ADSL G7070 debugging messages. Select to enable. Select a second time to disable. SDSL Mode (CellPipe IAD 4S/8S) Displays SDSL Configuration submenu, which contains the following commands to set the SDSL mode or speed. The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. 1. Toggle SDSL Mode (CO or CPE) 2. Set SDSL Speed to Auto Cycle (Nokia) Displays the Auto Cycle First Speed Option submenu, which contains the following commands to set the initial speed. 1. 1536 Kbps 2. 1152 Kbps 3. 768 Kbps 4. 384 Kbps 5. 192 Kbps Lucent Technologies - 40 - CellPipe™ IAD Series User’s Guide Select your choice. 3. Set SDSL Speed to Auto Sense (Copper Mountain) 4. Enable/Disable Conexant AutoBaud Mode Enables and disables the Conexant AutoBaud rate adaptation mode. 5. Set SDSL Sync Delay (Lucent) Sets the SDSL sync delay. Follow the on-screen messages to disable AutoBaud. You must disable AutoBaud to set the SDSL sync delay. 6. Set SDSL to AccessLan CPE Mode 7. Set SDSL for IMAS DSLAM (Nortel) 8. Set SDSL Speed Manually Sets the SDSL speed, a value between 144-2,320 Kbps. Type the SDSL data rate value, and then press ENTER. 9. SDSL Interface Mode (Bit Order) D. SDSL Debug Menu Displays the SDSL Debug Options submenu, which contains the following commands: 1. Restart SDSL Activation Sequence Restarts the SDSL activation sequence. 2. Enable/Disable SDSL AutoBaud Debug Messages Enables and disables the display of SDSL AutoBaud debugging messages. Select to enable. Select a second time to disable. 3. Enable/Disable SDSL Debug Messages Enables and disables the display of SDSL debugging messages. Select to enable. Select a second time to disable. 4. Enable/Disable Sync Msgs Enables and disables the display of configuration synchronization messages. Select to enable. Select a second time to disable. 5. Preactivation Debug Mode Enables and disables the preactivation debug messages. Select to enable. Select a second time to disable. Select your choice. Lucent Technologies - 41 - CellPipe™ IAD Series User’s Guide T1 Mode (CellPipe IAD 8T) Displays the T1 Configuration Menu, which contains the following commands: 1. Select Frame Mode (D4 or ESF) Displays the Select T1 Frame Mode submenu, which contains the following commands to set the T1 frame mode. 1. ESF Frame Mode 2. D4 Frame Mode Select your choice. 2. Select Line Build Out Displays the Select Line Build Out submenu, which contains the following commands to set the distance between the IAD and the demarc. Check with your service provider for the appropriate signal loss (dB). 1. 0 to 133 Feet (0 dB) 2. 133 to 266 Feet 3. 266 to 399 Feet 4. 399 to 533 Feet 5. 533 to 655 Feet 6. -7.5 dB 7. -15 dB 8. -22.5 dB Select your choice. 3. Enable/Disable B8ZS Enables and disables Binary 8 Zero Substitution (B8ZS) line code. 6. Configure Transmit Channels Displays the Channel Configuration Menu, which contains the following commands to set the number of transmission channels (maximum 24) for the WAN Interface: 1. Enable All Channels 2. Disable All Channels 3. Select Individual Channels 4. Select Channel Range Select your choice. Your settings display in the T1 Transmit Channels diagram. For more information, see the Reports_menu section earlier in this chapter. Lucent Technologies - 42 - CellPipe™ IAD Series User’s Guide 7. Configure Receive Channels Displays the Channel Configuration Menu, which contains the following commands to set the receiving channels (maximum 24) for the WAN Interface. 1. Enable All Channels 2. Disable All Channels 3. Select Individual Channels 4. Select Channel Range Select your choice. Your settings display in the T1 Receiving Channels diagram. For more information, see the Reports_menu section earlier in this chapter. 8. Configure Tx Clock Source Displays the Select Tx Clock Source submenu, which contains the following commands to set the clock source. 1. External (Slave Mode) 2. Internal (Master Mode) Select your choice. 9. Change to E1 Mode Switches the T1/E1 interface to E1 mode. E1 Mode (CellPipe IAD 8T) This mode currently not supported. Displays E1 Configuration Menu that contains the following commands: 1. Select Frame/CRC4 Mode Displays the Select E1 Frame Mode submenu that contains the following commands to set the E1 frame mode. 1. FAS 2. FAS (CRC4 Enabled) 3. Multi-Frame CAS 4. Multi-Frame CAS (CRC4 Enabled) Select your choice. Lucent Technologies - 43 - CellPipe™ IAD Series User’s Guide 3. Configure S-Bits Displays the current S-Bit configurations, and then displays the Current S-Bit Menu that contains the following commands to set and clear the selected S-Bit. 2. Toggle Sa4 Bit 3. Toggle Sa5 Bit 4. Toggle Sa6 Bit 5. Toggle Sa7 Bit 6. Toggle Sa8 Bit 4. Configure Transmit Channels Displays the Channel Configuration Menu, which contains the following commands to set the number of transmission channels (maximum 31) for the WAN Interface. 1. Enable All Channels 2. Disable All Channels 3. Select Individual Channels 4. Select Channel Range Select your choice. Your settings display in the E1 Transmit Channels diagram. For more information, see the Reports_menu section earlier in this chapter. 5. Configure Receive Channels Displays the Channel Configuration Menu, which contains the following commands to set the receiving channels (maximum 31) for the WAN Interface. 1. Enable All Channels 2. Disable All Channels 3. Select Individual Channels 4. Select Channel Range Select your choice. Your settings display in the E1 Receive Channels diagram. For more information, see the Reports_menu section earlier in this chapter. 6. Configure Clock Source Displays the Select Tx Clock Source submenu, which contains the following commands to set the clock source. 1. External (Slave Mode) 2. Internal (Master Mode) Select your choice. Lucent Technologies - 44 - CellPipe™ IAD Series User’s Guide 7. Change to T1 Mode Switches the T1/E1 interface to T1 mode. 3. Configure DLCIs (Frame Relay) Displays the FR DLCI Config Menu, which contains the following commands to set the current DLCI value. 1. Add New DLCI Type the DLCI number, press ENTER, and then choose a command from the FR Encapsulation Configuration submenu. 1. RAW (No Encapsulation) 2. Proprietary Voice DLCI 3. RFC 1490 4. ATM RFC 1483 (Tunneling) Select your choice, and then choose a command from the FR DLCI Options submenu. 1. Configure Transmit CIR Follow the on-screen messages to enter the following information. Questions below may not display, depending on the options that you select. • Transmit Committed Information Rate (CIR) • Committed burst size (Bc) • Circuit Throughput • Excess burst size (Be) The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. 2. Configure Receive CIR Follow the on-screen messages to enter the following information. Questions below may not display, depending on the options that you select. • Receive Committed Information Rate (CIR) • Committed burst size (Bc) • Circuit Throughput • Excess burst size (Be) The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Lucent Technologies - 45 - CellPipe™ IAD Series User’s Guide 3. Configure FRF.12 Fragmentation Displays the End-to-End Fragmentation Configuration submenu, which contains the following commands. 1. Enable/Disable End-to-End FRF.12 Enables and disables End-to-End FRF.12. 2. Set Fragmentation Size Sets the maximum fragmentation size, a value between 100-1,600 bytes. Type the fragmentation size, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Select your choice. 2. Modify Existing DLCI Type the DLCI number, press ENTER, and then choose a command from the FR Encapsulation Configuration submenu. 1. RAW (No Encapsulation) 2. Proprietary Voice DLCI 3. RFC 1490 4. ATM RFC 1483 (Tunneling) Select your choice, and then choose a command from the FR DLCI Options submenu. 1. Configure Transmit CIR Follow the on-screen messages to enter the following information. Questions below may not display, depending on the options that you select. • Transmit Committed Information Rate (CIR) • Committed burst size (Bc) • Circuit Throughput • Excess burst size (Be) The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. 2. Configure Receive CIR Follow the on-screen messages to enter the following information. Questions below may not display, depending on the options that you select. • Receive Committed Information Rate (CIR) • Committed burst size (Bc) Lucent Technologies - 46 - CellPipe™ IAD Series User’s Guide • Circuit Throughput • Excess burst size (Be) The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. 3. Configure FRF.12 Fragmentation Displays the End-to-End Fragmentation Configuration menu, which contains the following commands. 1. Enable/Disable End-to-End FRF.12 Enables and disables End-to-End FRF.12. 2. Set Fragmentation Size Sets the maximum fragmentation size, a value between 100-1,600 bytes. Type the fragmentation size, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Select your choice. 3. Delete DLCI Type the number of the port to delete, and then press ENTER. 4. Show Current DLCIs Displays encapsulation information about the active DLCI values on per port basis. You must restart the CellPipe IADs for any changes to take effect. For more information on restarting the CellPipe IADs, see the CellPipe IAD basics chapter. 3. Configure PVCS (ATM) Displays the ATM PVC Config Menu, which contains the following commands to set the current Permanent Virtual Circuit (PVC) Virtual Port Identifier (VPI) and Virtual Circuit Identifier (VCI) values by port: 1. Add New PVC Type the VPI, the VCI, and then choose a command from the ATM Encapsulation Configuration submenu. Lucent Technologies - 47 - CellPipe™ IAD Series User’s Guide 1. AAL5 (None) Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the Peak Cell Rate (PCR) value. 2. AAL0 (None) Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the PCR value. 3. Proprietary Voice Select for Voice encapsulation over a specific PVC. 4. RFC 1483 (using VC Muxing) Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the PCR value. This options supports either routing or bridging, but not both. 5. RFC 1483 (with LLC Encapsulation) Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the PCR value. Lucent Technologies - 48 - CellPipe™ IAD Series User’s Guide 6. RFC 2364 (PPPoATM with LLC Encapsulation) Displays the following commands to set the PPP authorization type: 0. None 1. PAP Client 2. PAP Server 3. CHAP Client 4. CHAP Server Select your choice, and then follow the on-screen messages to enter the following: • New PPP Userid • New PPP Password • New CHAP Peer Name Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the PCR value. 7. RFC 2364 (PPPoATM using VC Muxing) Displays the following commands to set the PPP authorization type: 0. None 1. PAP Client 2. PAP Server 3. CHAP Client 4. CHAP Server Select your choice, and then follow the on-screen messages to enter the following: • New PPP Userid • New PPP Password • New CHAP Peer Name Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the PCR value. Lucent Technologies - 49 - CellPipe™ IAD Series User’s Guide 8. AAL1/CES Sets the maximum Peak Cell Rate (PCR) for the line speed. Type the PCR value, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. 9. AAL2/LES Displays the AAL2 Audio Profile Format submenu, which contains the following commands to set the audio profile format: 1. ITU 2. ATM Forum Displays the AAL2 Audio Profile submenu, which allows you to set the audio profile. Select your choice, and then follow the on-screen messages to set the PCR value. Select your choice. 2. Modify Existing PVC Type the virtual port identifier (VPI), the virtual circuit identifier (VCI) and then choose a command from the ATM Encapsulation Configuration submenu. 1. RAW (AAL5) Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the PCR value. 2. RAW (AAL0) Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the PCR value. 3. Proprietary Voice Select for Voice encapsulation over a specific PVC. Lucent Technologies - 50 - CellPipe™ IAD Series User’s Guide 4. RFC 1483 (using VC Muxing) Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the PCR value. This option supports either routing or bridging, but not both. 5. RFC 1483 (with LLC Encapsulation) Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the PCR value. 6. RFC 2364 (PPPoATM with LLC Encapsulation) Displays the following commands to set the PPP authorization type: 0. None 1. PAP Client 2. PAP Server 3. CHAP Client 4. CHAP Server Select your choice, and then follow the on-screen messages to enter the following: • New PPP Userid • New PPP Password • New CHAP Peer Name Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the onscreen messages to set the PCR value. Lucent Technologies - 51 - CellPipe™ IAD Series User’s Guide 7. RFC 2364 (PPPoATM using VC Muxing) Displays the ATM Service Category Configuration submenu, which contains the following commands to set the service category: 1. CBR 2. UBR Select your choice, and then follow the on-screen messages to set the PCR value. 8. AAL1/CES Sets the maximum Peak Cell Rate (PCR) for the line speed. Type the PCR value, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. 9. AAL2/LES Displays the AAL2 Audio Profile Format submenu, which contains the following commands to set the audio profile format: 1. ITU 2. ATM Forum Displays the AAL2 Audio Profile submenu, which allows you to set the audio profile. Select your choice, and then follow the on-screen messages to set the PCR value. Select your choice. 3. Delete PVC Type the number of the port to delete, and then press ENTER. 4. Show Current PVCs Displays statistical information about the active PVC values on a per port basis. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the CellPipe IAD basics chapter. 4. Configure FR Options (Frame Relay) Displays the Frame Relay Options submenu, which contains the following commands to set the Frame Relay options Lucent Technologies - 52 - CellPipe™ IAD Series User’s Guide 1. Configure Fragmentation Displays the FR Fragmentation Configuration submenu, which contains the following commands to configure fragmentation. 1. Configure FRF.12 Fragmentation Displays the FR FRF.12 Configuration submenu, which contains the following commands. 1. Enable/Disable FRF.12 Enables and disables FRF.12 fragmentation. 2. Enable Automatic Fragment Sizing 3. Set Manual Fragment Size Sets the maximum fragment size, a value between 0-50 ms or 100-1600 bytes. Type the fragment size, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. 2. Configure Copper Mountain Fragmentation Displays the FR FRF.12 Configuration submenu, which contains the following commands. 1. Enable/Disable CuMtn Fragmentation Enables and disables Copper Mountain fragmentation. 2. Set Real-Time DLCI Sets a real time value for a DLCI port. Type the number of the port, and then press ENTER. 2. Configure Maintenance Protocol Displays the Frame Relay Maintenance Protocol submenu, which contains the following commands to set the Frame Relay maintenance protocol: 0. None 1. CCITT Q.933 Annex a Network 2. CCITT Q.933 Annex a User 3. CCITT Q.933 Annex a Both 4. ANSI T1.617 Annex D Network 5. ANSI T1.617 Annex D User 6. ANSI T1.617 Annex D Both 7. LMI Network (FRF.1.1) 8. LMI User (FRF.1.1) 9. LMI Both (FRF.1.1) Select your choice. Lucent Technologies - 53 - CellPipe™ IAD Series User’s Guide 3. Configure Congestion Parameters Displays the FR Congestion Configuration submenu, which contains the following commands to configure fragmentation. 1. Configure Transmit Congestion Parameters Follow the on-screen messages to enter the following transmit congestion parameter information. • FECN/BECN condition set size • FECN/BECN condition clear size • FECN/BECN maximum number of bytes to store 2. Configure Receive Congestion Parameters Follow the on-screen messages to enter the following receive congestion parameter information. • FECN/BECN condition set size • FECN/BECN condition clear size • FECN/BECN maximum number of bytes to store Select your choice. 4. Enable/Disable Copper Mountain CMCP Enables and disables the Copper Mountain Control Protocol (CMCP). Your settings display in the Display Current Configuration command in the Reports Menu. For more information, see the Reports Menu section earlier in this chapter. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the CellPipe IAD basics chapter. 4. Configure ATM Options (ATM) Displays the ATM Configuration Menu, which contains the following submenus and commands to configure the ATM options. 1. Configure Payload Scrambling Enables and disables payload scrambling. 2. Configure F4 OAM VPI Sets the F4 OAM VPI value, a value between 0 and 255. Type the VPI value, and then press ENTER. The VPI value must match the VPI from a currently configured PVC. Lucent Technologies - 54 - CellPipe™ IAD Series User’s Guide 3. Configure F4 OAM Type Displays the F4 OAM Type Configuration Menu, which contains the following options to set the F4 OAM type. 0. None 4. F4 End to end OAM Select your choice. 4. Display F4 OAM Configuration Displays the F4 OAM type. 5. Send OAM Loopback Sends an OAM Loopback cell on the port that you select. 6. Configure EmptyCells Configures any empty cells. Type 1 to configure idle cells or 2 to configure unassigned cells. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the CellPipe IADs basics chapter. 6. Configure LAN Displays the LAN Configuration Menu, which contains the following command: F. Set/Clear Full Duplex Enables and disables full duplex Ethernet mode, which allows simultaneous transmission and receipt of Ethernet packets. Type the number of the port, select enable or disable, and then press ENTER. Your settings display in the Display Current Configuration command in the Reports Menu. For more information, see the Reports Menu section earlier in this chapter. 7. Configure SNMP Displays the SNMP Configuration Menu, which contains the following commands to configure the simple network management protocol (SNMP). Lucent Technologies - 55 - CellPipe™ IAD Series User’s Guide E. Enable/Disable SNMP Enables and disables SNMP. P. Configure System Contact Sets the name of the SNMP contact person (maximum = 39 alphanumeric characters). Type the new system contact information, and then press ENTER. N. Configure System Name Sets the name of the SNMP host server (maximum = 39 alphanumeric characters). Type the descriptive information, and then press ENTER. L. Configure System Location Sets the location of the SNMP host server (maximum = 39 alphanumeric characters). Type the new location information, and then press ENTER. C. Configure SNMP Community Sets the SNMP read-write community to which your device belongs (maximum = 39 alphanumeric characters). This name must match the name of the SNMP host. Type the name, and then press ENTER. If you enable SNMP and the read-write Community Name is null, SNMP goes into read-only mode with a Community Name of "public". T. Configure SNMP Trap Host IP Address Sets the IP address of the system setup for trap operations. Type the IP address, and then press ENTER. 8. Configure Login Displays the Password Configuration Menu, which contains the following commands to set the default User ID/password pairs at the User, Network Administrator and Supervisor levels. It also allows you to set the primary and secondary IP addresses and encryption keys for a Remote Authentication Dial-In User Services (RADIUS) server, which determine the validity of unknown User ID/password pairs. Lucent Technologies - 56 - CellPipe™ IAD Series User’s Guide You must have a functional RADIUS server to use this feature. For more information on RADIUS servers, see RFC 2865. If you configure a RADIUS server, you must use a RADIUSauthenticated User ID/password for Telnet access. If the RADIUS server goes down, Telnet access will not work. For more information on changing the User ID, password or the primary and secondary IP addresses or encryption keys for the RADIUS server, see the Administration chapter. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the CellPipe IAD basics chapter. 1. Change User ID Changes the default User ID. Type the new User ID (maximum 17 alphanumeric characters), and then press ENTER. 2. Change User Password Changes the default User password. Type the new password (maximum 17 alphanumeric characters), and then press ENTER. Retype the new password, and then press ENTER. 3. Change NetMan Password Changes the default Network Administrator password. Type the new password (maximum 17 alphanumeric characters), and then press ENTER. Retype the User password, and then press ENTER. 4. Change Supervisor Password Changes the default Supervisor password (factory default = supervisor). Type the new password (maximum 17 alphanumeric characters), and then press ENTER. Retype the new password, and then press ENTER. 5. Change Primary RADIUS Server Address Changes the primary RADIUS server address. Type the new address as either an IP address or fully qualified host and domain names (for example: radius.polycom.com - maximum 42 bytes), and then press ENTER. If you enter host and domain names, you must configure the DNS client. For more information, see the Configure_DNS_client section earlier in this chapter. Lucent Technologies - 57 - CellPipe™ IAD Series User’s Guide 6. Change Primary RADIUS Encryption Secret Changes the primary RADIUS encryption key. Type the new primary key (maximum 17 alphanumeric characters), and then press ENTER. 7. Change Secondary RADIUS Server Address Changes the secondary RADIUS server address. Type the new address as either an IP address or a fully qualified host and domain name (for example: radius.polycom.com), and then press ENTER. If you enter host and domain names, you must configure the DNS client. For more information, see the Configure_DNS_client section earlier in this chapter. 8. Change Secondary RADIUS Encryption Secret Changes the secondary RADIUS encryption key. Type the new secondary key (maximum 17 alphanumeric characters), and then press ENTER. 9. Display RADIUS Configuration Displays the following information about the RADIUS server: • Primary RADIUS Server - primary IP address or fully qualified host and domain names. • Primary RADIUS Secret - primary encryption key. • Secondary RADIUS Server - primary IP address or fully qualified host and domain names. • Secondary RADIUS Secret - secondary encryption key. 9. System Utilities Displays the Utilities Menu, which contains the following submenus and commands to either upgrade the ACOS software or support ACOS application development. Except for Ping Utility and Trace Route, these commands are only for application development, software upgrades, or to restore factory defaults. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the CellPipe IAD basics chapter. Lucent Technologies - 58 - CellPipe™ IAD Series User’s Guide P. Ping Utility Uses the Ping protocol to check for the presence of a host on the Internet. Type the following information, and then press ENTER: • IP address or complete host name to Ping** • Ping packet size • Number of times to Ping ** You must enter the domain name with the host name. For example, mycomputer.mydomain.com. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. T. Trace Route Traces the route to a specific host. Enter the IP address or host name** to trace, and then press ENTER. ** You must enter the domain name with the host name. For example, mycomputer.mydomain.com. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Z. Configure Console Baud Rate Displays the following commands to set the console Baud rate: 0. Unset (use Default) 1. 9600 2. 19200 3. 38400 4. 57600 5. 115200 Select your choice. V. Configure Console Timeout Sets the console timeout, a value between 0-60 minutes (default = 3 minutes). Type the timeout value, and then press ENTER. A value of 0 (zero) disables this feature. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Lucent Technologies - 59 - CellPipe™ IAD Series User’s Guide R. Hard Reset or Reload ACOS from FLASH Restarts the CellPipe IAD using all values set during the active session and reloads ACOS from FLASH memory. For more information, see the CellPipe IAD basics chapter. D. Set System Defaults Switches to the factory default configuration. W. Save System Settings as Defaults Saves the current system settings as the default configuration. A. Clear ’Last Reset Reason’ Deletes any reset instructions from the CellPipe IAD. F. File System Menu Displays the File System Menu, which contains the following commands to support IAD application development. D. Directory of all Files Displays a list of all files stored in Flash memory in the CellPipe IADs. C. Copy file Copies and saves the entered file under a new file name. Type the name of the file to copy, and then type the new file name. R. Rename File Replaces the old file name with a new one. Type the old file name, and then type the new one. X. Remove File by name Deletes the entered file from the file system. F. Format File System drive Deletes all files in the file system, including the configuration file (config.st). If you delete the configuration file, you will have to reconfigure every setting. S. Space left in File System Displays the available space (bytes) in the file system. Lucent Technologies - 60 - CellPipe™ IAD Series User’s Guide G. Debug Menu Displays the Debug Menu, which contains the following commands to set various debugging options. M. Set Ethernet MAC Sets the Ethernet MAC address. Type the new address, and then press ENTER. E. Enable/Disable PPP debug mode Enables and disables the display of PPP Debug messages. S. Enable/Disable STP debug mode Enables and disables the display of the Spanning Tree protocol (STP) debug messages. I. Enable/Disable DHCP Client debug mode Enables and disables the display of DHCP Client debug messages. Q. Display Error Dump Displays the most recent error encountered during the active session on the screen. For factory use only. X. File Transfer Menu Displays the File Transfer Menu, which contains the following commands to transfer files on to the CellPipe IADs. B. Load Boot ROM Displays the File Transfer Method submenu, which contains the following commands to download the Boot ROM to the file system stored in Flash memory in the CellPipe IADs: 1. Receive via TFTP 2. Receive via XMODEM Select your choice. Lucent Technologies - 61 - CellPipe™ IAD Series User’s Guide O. Update ACOS [acos.bin] Displays the File Transfer Method submenu, which contains the following commands to download the acos.bin file to the file system stored in Flash memory in the CellPipe IADs: 1. Receive via TFTP 2. Receive via XMODEM Select your choice. Type the IP address of the computer that is serving as a TFTP server, and then type the name of the file to download. You must restart the CellPipe IAD after loading the software. For more information on restarting the CellPipe IADs or on upgrading your software using TFTP, see the CellPipe IAD basics chapter. X. Update Entire System Uses TFTP to download files to update the CellPipe IADs. A. File Transfer Utilities Displays the File Transfer Method submenu, which contains the following commands to download a file to the file system stored in Flash memory in the CellPipe IADs: 1. Receive via TFTP 2. Send or Receive via XMODEM Select your choice. D. Configure DHCP Server Displays the DHCP Server Configuration Menu, which contains the following commands to configure DHCP. DHCP dynamically assigns an IP address to all devices connected to the CellPipe IADs. You must select the Ethernet Interface to correctly use the following commands. You must restart the CellPipe IADs for the changes to take effect. For more information on restarting the CellPipe IADs or on upgrading your software using TFTP, see the CellPipe IAD basics chapter. Lucent Technologies - 62 - CellPipe™ IAD Series User’s Guide E. Enable/Disable DHCP Enables and disables DHCP. B. Enable/Disable DHCP Debug Messages For factory use only. I. Configure DHCP Server Parameters Sets the DHCP server parameters. Type the number of the Interface, the number of the port, the following information, and then press ENTER: • Gateway IP address • DNS Server IP address • Subnet Mask • Domain Name • DHCP Lease Time The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Your settings display in the Display DHCP Configuration command. P. Configure DHCP Address Range Pool Sets the DHCP IP address range. Type the high IP address, the low IP address, and then press ENTER. Both IP addresses must be on the same Subnet mask. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. C. Configure DHCP Client Entry Assigns the same IP address every time to the client that you enter. Type the following information, and then press ENTER: • Client entry number • DHCP Client MAC address (enter value without colons) • Host Name • Lease Time • IP Address • Subnet Mask Lucent Technologies - 63 - CellPipe™ IAD Series User’s Guide • Default Gateway • DNS Server Your settings display in the Display DHCP Entry Details command. F. Display DHCP Configuration Displays the following information about the DHCP configuration: • Net Interface - active slot number. • Default gateway - IP address of packets sent to DHCP Clients. • Default DNS server - IP address of the DNS server. • Default subnet - IP subnet mask; number of bits reserved for the host ID. • Domain name - defines the entity that owns the IP address. For example, commengines.com. • Default lease - length of time to keep the Internet connection active. • High address - maximum IP address to assign. • Low address - minimum IP address to assign. • Client Number - client entry number. • Host name - name of the host. • IP address - IP address of outgoing interface. • Subnet mask - IP subnet mask; number of bits reserved for the host ID. • Lease time - length of time to keep the Internet connection active. • Gateway - IP address of packets sent to destination. • DNS Server - IP address of the DNS server. S. Display DHCP Server Statistics Displays the following information about the DHCP Server. • plain bootp requests received • plain bootp replys sent • discover packets sent • offer packets sent • dhcp request packets received • declines received • releases received Lucent Technologies - 64 - CellPipe™ IAD Series User’s Guide • • • • acks sent nacks sent requests for other servers protocol errors For the preceding to display, you must attach DHCP Client devices that use DHCP to obtain an IP address to the CellPipe IADs. A. Display DHCP Server Assigned Addresses Displays the following information about the DHCP Server assigned addresses. • IP - IP address of the device, assigned by the CellPipe IADs. • Client ID - Ethernet MAC address for the device. • Status - how the IP address is assigned to the device: through DHCP or manually. For the preceding to display, you must attach DHCP Client devices that use DHCP to obtain an IP address to the CellPipe IADs. D. Display DHCP Entry Details Displays the following information about the DHCP entries. • • • • IP address - IP address of the device. Client ID - Ethernet MAC address for the device. Status - how the IP address is assigned to the device: through DHCP or manually. Subnet - IP subnet mask; number of bits reserved for the host ID. Gateway - IP address of packets sent to destination. DNS - IP address of the DNS server. Lease - length of time to keep the Internet connection active. Type - type of IP address: static or dynamic. • Name - name of the device. • • • • For the preceding to display, you must attach DHCP Client devices that use DHCP to obtain an IP address to the CellPipe IADs. Lucent Technologies - 65 - CellPipe™ IAD Series User’s Guide X. Delete a DHCP Client Entry Deletes a Client entry from the Display DHCP Configuration command. Type the Client number to delete, and then press ENTER. Y. Delete a DHCP Assignment Entry Deletes an assigned IP address from the Display DHCP Server Assigned Addresses command. Type the IP address to delete, and then press ENTER. N. Configure NAT Displays the NAT Configuration Menu, which contains the following commands to configure the Network Address Translation (NAT). NAT allows you to use one IP address to represent every workstation in your company. This hides your internal Intranet addresses. You must restart the CellPipe IAD for the changes to take effect. For more information on restarting the CellPipe IADs or on upgrading your software using TFTP, see the CellPipe IAD basics chapter. B. Enable/Disable NAT Debug Messages Enables and disables NAT debugging messages. P. Enable/Disable NAT Translation by Port Enables and disables NAT by port. Type the number of the Interface, the number of the port to enable, and then press ENTER. You must enable NAT for all ports that connect to the Internet. T. Configure NAT TCP Timeout Sets the NAT TCP Connection Timeout, a value between 60 3,600 seconds (default = 300 seconds). Type the TCP Timeout value, and then press ENTER. U. Configure NAT UDP Timeout Sets the NAT UDP Connection Timeout, a value between 603,600 seconds (default = 120 seconds). Type the UDP Timeout value, and then press ENTER. Lucent Technologies - 66 - CellPipe™ IAD Series User’s Guide R. Configure NAT Port Range Sets the range of port numbers to assign to IP connections, with a low value between 5,000-65,534 (default = 50,000) and a high range between 50,000-65,535 (default = 65,535). The size of the NAT port range defines the number of simultaneous connections permitted. A small port range limits the number of connections. Since the range that you assign must be outside the range of the programs in use, do not set port ranges under 5,000. Type the Low End of NAT Port Range value, the High End of NAT Port Range value, and then press ENTER. N. Configure NAT Local Server Entry Makes local servers visible to the Internet. Type the following information, and then press ENTER: • Local Server entry number • NAT Local Server Translated IP address • NAT Local Server Translated Port Number • NAT Local Server Standard Port Number • NAT Local Server Protocol The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Your settings display in the Display NAT Local Server Table command. S. Display NAT Statistics Displays the following information about the NAT configuration: • Local IP - IP address in use. • Timeouts - TCP and UDP Timeout values. • Local to inet - number of packets and bytes transferring to the Internet. • inet to Local - number of packets and bytes receiving from the Internet. • Connections - the number of active TCP, UDP and ICMP connections, as well as the number created and deleted. • Errors - the number of cksum, retries and bad packets. • Total IP packets - number of IP packets received and sent. Lucent Technologies - 67 - CellPipe™ IAD Series User’s Guide • Reserved addresses - number of reserved IP addresses. C. Display NAT Connection Table Displays the following information about the NAT connections: • TCP - Ethernet MAC address of the device. • out_port • pkts - out, in • state • idle D. Display NAT Connection Details Displays the following information about the NAT connections: • Outside port number of connection • Foreign IP • Local IP • # Ports - outside, inside, foreign • Outgoing packets/# bytes • Incoming packets/# bytes • Type - TCP or UDP • Seconds since use • TCP/UDP Sequence • Ack • State • Retrys - local, foreign • Bad checksum - local, foreign O. Display NAT Local Server Table Displays the following information about the local server: • • • • • Entry - table entry number. Local IP Address - IP address in use. Local Port - local port number. Internet Port - Internet port number. Protocol - TCP or UDP. X. Delete IP Address from NAT Tables Deletes an IP address entry from the Display NAT Statistics, Display NAT Connection Table and Display NAT Lucent Technologies - 68 - CellPipe™ IAD Series User’s Guide Connection Details commands. Type the IP address to delete, and then press ENTER. Y. Delete NAT Local Server Entry Deletes an NAT Local Server entry from the Display NAT Statistics, Display NAT Connection Table and Display NAT Connection Details commands. Type the Local Server entry to delete, and then press ENTER. T. Derived Timing Displays the Derived Timing submenu, which contains the following commands to enable/disable derived timing and display debugging messages. 1. Enable/Disable Derived Timing Enables and disables derived timing. You must restart the CellPipe IAD for the changes to take effect. For more information on restarting the CellPipe IADs or on upgrading your software using TFTP, see the CellPipe IAD basics chapter. 2. Enable/Disable Derived Timing Debug Messages Displays the Derived Timing Debug submenu, which contains the following commands to enable/disable derived timing debugging messages. 1. Enable/Disable **ALL** Derived Timing Debug Messages Displays the Derived Timing Debug submenu, which contains the following commands to enable/disable all derived timing debugging messages. 1. Enable 2. Disable Select your choice. 2. Enable/Disable **PSTN ONLY** Derived Timing Debug Messages Displays the Derived Timing Debug submenu, which contains the following commands to enable/disable only PSTN derived timing debugging messages. 1. Enable 2. Disable Select your choice. Lucent Technologies - 69 - CellPipe™ IAD Series User’s Guide 3. Enable/Disable **Local Clock ONLY** Derived Timing Debug Messages Displays the Derived Timing Debug submenu, which contains the following commands to enable/disable only local clock derived timing debugging messages. 1. Enable 2. Disable Select your choice. Select your choice. Z. Diagnostics Menu Displays the Diagnostics submenu, which contains the following command. P. POTS Diagnostics Displays the POTS Diagnostics submenu, which contains the following tests for the voice lines. D. Dialup Test Allows you to place calls between POTS lines without a WAN connection to a voice gateway. H. Hotline Test Allows line to line telephone connections on a single unit without requiring a voice gateway connection on the WAN port. S. Power Supply Test Checks the CellPipe IAD power supply, CODEC, and SLIC. P. Phone Detect Test Detects POTS devices on each of the POTS ports. R. Ring Test Rings all POTS lines either simultaneously or one at a time in sequence. O. On/Off Hook Test Reports the hook state - On or Off - of each POTS line. Select your choice. Lucent Technologies - 70 - CellPipe™ IAD Series User’s Guide R. Reset System Restarts the CellPipe IADs, using all values set during the active session. For more information on restarting the CellPipe IADs, see the CellPipe IAD basics chapter. P. VoicePath Configure Displays the Voice Configuration submenu, which contains the following commands: V. Set Voice Gateway Displays the Voice Gateway Selection submenu, which contains the following commands to set the voice gateway. 0. No Voice Gateway 1. TollBridge 2. CopperCom 3. MGCP 0.1/NCS 1.0 4. JetStream 5. AAL2/LES 6. TdSoft Select your choice. J. Set Jitter Delay Sets the jitter delay, a value between 0 and 50 ms (default = 0 ms). Jitter delay is defined as: Jitter Equation [CASZ97]2 Inter-arrival jitter is the difference in relative transit time for two packets. It is the difference between the packet’s RTP time-stamp and the receiver’s clock at the time of arrival of the packet. As shown in the equation below, this is equivalent to the difference in the relative transit time for two packets: the relative transit time is the difference between a packet’s RTP time-stamp and the receivers clock at the time of arrival, measured in the same units. If Si is the RTP time-stamp from packet i, and Ri is the time of arrival in RTP time-stamp units for packet i, then for two packets i and j, D can be expressed as: D(ij) = (Rj -Ri) -(Sj -Si) = (Rj -Sj) -(Ri -Si) Lucent Technologies - 71 - CellPipe™ IAD Series User’s Guide The interval jitter is calculated continuously as each data packet i is received from source SSRC-n, using this difference D for that packet and of the previous packet i-1 in order of arrival (not necessarily in sequence), according to the formula: J = J + ({D (i-l, i)} -J)/16 This value should only be set by your Network Administrator. D. Display Jitter Delay Displays the jitter delay value. S. Set Start Mode (Loop Start/Ground Start) Displays the Start Mode Selection submenu, which contains the following commands to set the Start Mode: 1. Set All Ports to Loop Start 2. Set All Ports to Ground Start 3. Display Start Mode 4. Configure Individual Port Follow the on-screen messages to configure the port(s). Select your choice. T. Set SLIC Control Mode Displays the SLIC Control Mode Selection submenu, which contains the following commands to set the SLIC Control Mode: A. AUTO Control Mode B. MANUAL Control Mode Select your choice. Voice gateway applications, such as CopperCom or JetStream, will override the value set by this command. U. Set Compander Mode (u-Law, a-Law) Displays the Compander Mode Selection submenu, which contains the following commands to set the Compander mode: U. u-Law Mode A. a-Law Mode Select your choice. Lucent Technologies - 72 - CellPipe™ IAD Series User’s Guide If you are not sure which mode to use, check with your telephone service provider. Normally, u-Law is used in North America and a-Law in Europe. O. Set On Hook Transmission Mode of Ground Start Lines Displays the Ground Start OHT Mode Selection submenu, which contains the following commands. E. ENABLE Ground Start On Hook Transmission D. DISABLE Ground Start On Hook Transmission Select your choice. M. Set Debug Mode Displays the Debug Mode Selection submenu, which contains the following commands. E. ENABLE Debug D. DISABLE Debug Select your choice. E. Configure Echo Cancellation Default Settings Displays the Echo Cancellation Default Settings Configuration Menu, which contains the following commands. 1. Set Echo Cancellation default setting for all ports Enables and disables echo cancellation globally. 2. Display current Echo Cancellation default settings Displays the following Echo Cancellation default settings: • • Line # - 1-16. Status - ENABLED or DISABLED 3. Configure Echo Cancellation default setting per port Enables and disables Echo Cancellation by port. Type the line number, press ENTER, and then enable or disable. Select your choice. Lucent Technologies - 73 - CellPipe™ IAD Series User’s Guide G. Set Loop Gain Displays the Configure Loop Gain Menu, which contains the following commands. If the CellPipe IAD feeds circuits into a legacy PBX or other equipment that defines levels to the network the TX and RX, the Loop Gain value must match the value of the circuit it supplies - the levels set and determined by the PBX manufacturer or the manufacturer of the terminating equipment. You must also change the Loop Gain value if there is a decrease in power between that transmitted and that received due to loss through equipment, lines or other transmission devices, degrades in service or customer perception. The following values should only be set by your Network Administrator. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. 1. Set Loop Gain for all ports Sets the Transmit (range = -9dB to 3dB; default = -2dB) and Receive (range = -9dB to 3dB; default = -4dB) Loop Gain values for all ports. Type the Transmit Loop Gain value, and then press ENTER. Type the Receive Loop Gain value, and then press ENTER. Your settings display in the Display current Loop Gain settings command. 2. Display current Loop Gain settings Displays the following information about the Loop Gain settings: • • • Port # - 1-16. Rx – Receive Loop Gain value. Tx – Transmit Loop gain value. 3. Configure Loop Gain setting per port Sets the Transmit and Receive Loop Gain values by port. Type the line number, the Transmit Loop Gain value, and then press ENTER. Type the Receive Loop Gain value, and then press ENTER. Select your choice. Lucent Technologies - 74 - CellPipe™ IAD Series User’s Guide E. Toggle CMCP Debugging Enables and disables Copper Mountain Control Protocol (CMCP) debugging. Select to enable - displays the number of transmitted and received CMCP packets (in bytes). Select a second time to disable. M. Manage MGCP/NCS Embedded Client Displays the MGCP/NCS Management Menu, which contains the following submenus and commands. C. Configure MGCP/NCS parameters Sets the MGCP/NCS parameters. Type the following information, and then press ENTER: • Default IP address for Notified Entity • IP address to use for MGCP signaling (Data) packets Type of Service (TOS) field value for the IP header of the outbound signaling packets IP address to use for RTP Transport (Voice) packets TOS field value for the IP header of the outbound RTP Transport packets • • • S. Display MGCP/NCS statistics Displays the Endpoint (line) and connection statistics. If no calls are active, only whether or not the Endpoint is currently connected to its Notified Entity displays. D. Debug MGCP/NCS Displays the MGCP Debug menu, which contains the following commands. 1. Disable all msgs 2. Enable Informational msgs 3. Enable Verbose msgs Select your choice. Lucent Technologies - 75 - CellPipe™ IAD Series User’s Guide R. Remove a connection Removes LOST connections. Type the number of the Connection ID to delete, and then press ENTER. A. Port Administration Displays the Port Administration Menu, which contains the following commands to set the following port options. These options are only available at the Network Administrator and Supervisor levels. For more information, see the Administration chapter. 1. Set Admin State for all ports Enables and disables all ports. 2. Display current Admin State Displays the status of all ports - enabled or disabled by port number. 3. Configure Admin State per port Enables and disables a port. Type the number of the port, press ENTER, and then enable or disable. 4. Restart Endpoint Resets the connection between the POTS phone and the MGCP voice gateway. You use this option if one side thinks a call is up and the other side thinks the call is down. Type the number of the port, and then press ENTER. Select your choice. P. Configure Default Packet Size Sets the default packet size (default = 5.5 ms). Type the packet size value, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Lucent Technologies - 76 - CellPipe™ IAD Series User’s Guide Call Control Displays the CopperCom Call Control submenu, which contains the following submenus and commands. S. Statistics Displays the CopperCom Statistics submenu, which contains the following commands. D. Display Statistics Displays the following error statistics: • • HEC Errors CID Errors C. Clear Statistics Select your choice. C. Configure Displays the CopperCom Configuration submenu, which contains the following commands. D. Display Configuration Displays the current configuration settings, by port number. C. Compression Format Sets compression globally or by port. Type the port number, select a compression, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Select your choice. D. Debug Control Displays the CopperCom Debug Control submenu, which contains the following commands. L. Display Line Status Displays the following information about the active line(s): • • • • Lucent Technologies Line State SLIC State Hook State - 77 - CellPipe™ IAD Series User’s Guide • • • Payload CPE Signal GWY Signal D. Display Debug State/Flags Displays the following information about the active debug state and flags: • Debugging – ENABLED or DISABLED. • Flags: o Globals (DT/PCHES) o T10 & T11 Timeouts o WAN Signaling o WAN Input Ready o POTS Input Ready o POTS Hook State C. Control Debug (Enable/Disable) Enables and disables debugging. S. Set Debug Flags Sets values for the following debug flags: • Globals (DT/PCHES) • T10 & T11 Timeouts • WAN Signaling • WAN Input Ready • POTS Input Ready • POTS Hook State The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Your settings display in the D. Display Debug State/Flags command. Select your choice. Lucent Technologies - 78 - CellPipe™ IAD Series User’s Guide E. Call Control Settings Displays the Call Control Settings submenu, which contains the following submenus and commands: A. Stats Display Displays the following statistical information: • WAN RX PKTS • WAN RX BYTES • WAN TX PKTS • WAN TX BYTES • WAN TX DROPPED • POTS RX PKTS • POTS RX BYTES • POTS TX PKTS • POTS TX BYTES • POTS TX DROPPED • L2 RX PKTS • L2 RX BYTES • L2 TX PKTS • L2 TX BYTES • AAL2 HEC ERROR Select your choice. R. Ring Test Displays the following commands: C. Configure Ring Test Enables the Ring Test. Type the following information, and then press ENTER: • Port to enable. • Number of seconds for port to stay on hook. • Number of seconds for port to stay off hook. Your settings display in the Display parameters command. D. Display Parameters Displays the following information about the Ring Test: Lucent Technologies - 79 - CellPipe™ IAD Series User’s Guide • • • Port On hook time Off hook time S. Start Ring Test Starts the Ring test. T. Stop Ring Test Stops the Ring test. Select your choice. S. Display IAD State Displays the on hook state for each port. T. Trace Displays Trace Settings submenu, which contains the following commands: S. Set Trace data Sets all Trace data. Type the following information, and then press ENTER: • L2 Module • Cc Module • Mg Module • L2 Subscriber • Cc Subscriber • Cc Port (16 total) The CellPipe IADs displays a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Your settings display in the Display Trace data command. D. Display Trace data Displays the following Trace data: • • • • • • Lucent Technologies L2 Module Cc Module Mg Module L2 Subscriber Cc Subscriber Cc Port (16 total) - 80 - CellPipe™ IAD Series User’s Guide V. Pick sound heard if insufficient WAN B/W to complete call Displays Insufficient Bandwidth Indication Setting submenu, which contains the following commands: 0. Play Silence 1. Play Fast Beeping Select your choice. U. Configure Tollbridge Voice Client Displays the Tollbridge Configuration Menu, which contains the following submenus and commands to configure the Tollbridge voice client. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. 0. Set Client IP address Sets IP address of the client. This address must match the IP address that you configure for the CellPipe IAD. Type the client IP address, and then press ENTER. 1. Set Voice Gateway IP Address Sets the voice gateway IP address. Type the voice gateway IP address, and then press ENTER. 2. Print Current Configuration Displays the following information about the Tollbridge voice client configuration: • • • Lucent Technologies Client IP address Gateway IP address Debug message flags (OFF or ON) o Status/keep-alive messages o Provisioning messages o State-transition messages - 81 - CellPipe™ IAD Series User’s Guide 3. Debugging options Displays the Tollbridge Debugging Options submenu, which contains the following commands to enable or disable Tollbridge debugging messages: 0. Enable/Disable all messages 1. Enable/Disable status/keep-alive messages 2. Enable/Disable provisioning messages 3. Enable/Disable state-transition messages Select your choice. A. Application Menu For the Application Menu to display, you must configure TdSoft on the first VPI/VCI combination and make sure: Datalink Protocol = ATM PVC type = AAL0 ATM Service Category = CBR ATM Peak Cell Rate (PCR) = Accept defaults The Application Menu contains the following submenus and commands: D. Display information Menu Displays the Display Information Menu, which contains the following commands: 1. Display pots database Displays information about the voice port that you select. Type the number of the port for which you want to display information, and then press ENTER. • User port no. - the port for which you want to display information. • Port context – number of the physical slot for the port interface. • Interface no. • Port – location of the port within the interface. For example, port #11 is in slot #2, location #2. • Port timer • Period Lucent Technologies - 82 - CellPipe™ IAD Series User’s Guide • • • Counter Port enabled – whether or not a voice path is configured for the port. Port ring – whether or not the port is currently ringing. 2. Display atm database Displays the following information about the ATM database: • Port context - number of the physical slot for the ATM port interface. • Slot no. • Interface no. • Port no. - location of the port within the interface. 3. Display CAS signaling Displays the channel associate signaling (CAS) signaling value (in hexadecimal) for each signaling type: • Off hook • On hook • Ringing • Normal 4. Display user port database Displays the following information about the user port database: • CID - Channel ID number • VPI - Virtual Path Indicator • VCI - Virtual Circuit Identifier • User port - active user port • ATM port - ATM VCC Port used for POTS. Should be 0 at all times, since you configured AAL0 as the first VCC. Lucent Technologies - 83 - CellPipe™ IAD Series User’s Guide 5. Display port statistics Displays information about the number of cells of input/output (I/O) type for the port number that you select. Follow the on-screen message to enter the following, and then press ENTER: • Interface type • I/O type • Port number 6. Display WAN speed Displays the current WAN speed. 7. Display IAD version Displays the current TdSoft version number. Select your choice. S. Set information Menu Displays the Set Information Menu, which contains the following commands. You must restart the CellPipe IADs for any changes to take effect. For more information on restarting the CellPipe IADs, see the CellPipe IAD basics chapter. 1. Set CAS signaling Sets the CAS signaling value (in hexadecimal) for each signaling type - Off hook, On hook, Ringing (RING ON) and Normal (RING OFF). Follow the on-screen message to enter the following, and then press ENTER: • Signaling type • Value (in hexadecimal) These settings are saved. When you reset the system, it uses the default values. 2. Set CAS signaling to default Sets the CAS signaling to the following values: CAS Signaling Value Off hook 0xf0 On hook 0x50 Lucent Technologies - 84 - CellPipe™ IAD Series User’s Guide Ringing Normal 0x0 0x50 3. Set user port database Before you connect a phone to a CellPipe IAD user port, you must assign a Channel ID (CID) and an ATM port number to the telephone port that you want to use. You can change the settings for each telephone port individually or set all ports at once by typing 99 when prompted for a port number. • To configure a single port, type the port number, and then a CID # (minimum = 16) and an ATM port number (ATM port numbers represent VCCs and are configurable on the WAN configuration menu). • To configure all ports at once, type 99 instead of a port number. The ATM port number that you enter is then assigned to all ports. The CID number that you enter is assigned to the first port, while consecutive CID numbers are automatically assigned to the following ports. Any changes in user-port settings take effect immediately - you do not have to restart the system. However, the settings are NOT saved (and will not remain after a system reset) unless you specifically use the Save user port information command to save them to a file. 4. Save user port information Saves the values that you set in the Set user port database command. The saved values automatically load the next time you restart the IAD. 5. Set loopback flag For factory use only. 6. Set print debug information flag Sets the print debug information flag. Follow the on-screen message to enter the following, and then press ENTER: • User port number (or 99 for all ports) • Print debug info flag - 0 (FALSE) or 1 (TRUE) When you set the print debug info flag to TRUE, messages display on-screen when the hook or voice path status for the port changes or when a timer attached to the port expires. Lucent Technologies - 85 - CellPipe™ IAD Series User’s Guide 7. Set start Tx counter Sets the number of cells to keep in the jitter delay buffer before the first cell leaves the buffer and sent to the ATM port (default = 3 cells). This value is in addition to the Set Jitter Delay command on the Voicepath Configuration submenu. Changing this parameter is NOT recommended. 8. Set TFTP Server address Sets the default IP address that displays when you use a TFTP Server to download files. 9. Set DSP codec type Sets the DSP codec type (ULAW or ALAW) for the port that you select. Follow the on-screen message to enter the following, and then press ENTER: • Port number • Codec type - ULAW or ALAW A. Set stop ringer time period Sets the amount of time for the stop ring timer to expire (default = 5 seconds). These settings do not save. When you reset the system, the default values redisplay. Changing this parameter is NOT recommended. Select your choice. A. AAL Type Menu Displays the AAL Menu, which contains the following commands: 1. Set AAL2 print debug information flag Displays the contents of the transmitted or received AAL2 cells. Follow the on-screen message to enter the following, and then press ENTER: • Direction – the cells that you want to monitor Transmit (incoming) or Receive (outgoing). • Status – whether or not to display messages FALSE or TRUE. • Counter – the number of the specific cell whose contents you want to display. Lucent Technologies - 86 - CellPipe™ IAD Series User’s Guide Enabling debug information can severely inhibit IAD performance. Use of this command is NOT recommended. 2. Display number of sequence errors Displays the number of errors in the AAL2 header SN field of the incoming cells. Select your choice. F. AAL2/LES Call Control Displays the AAL2/LES Call Control submenu, which contains the following submenus and commands. ATM Adaptation Layer 2/Loop Emulation Services (AAL2/LES) is a broadband local loop emulation service (specifically telephony) that uses the ATM AAL2 adaptation layer. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the CellPipe IAD basics chapter. C. Configuration Displays the AAL2/LES Configuration submenu, which contains the following submenus and commands. C. CAS Signaling Displays the AAL2/LES CAS Signaling submenu, which contains the following commands. S. Toggle CAS signaling: GR-303 ABCD (US) or MEL TS16 (UK) Switches CAS signaling between GR-303 ABCD (US) or MEL TS16 (UK). R. Turn on/off CAS refreshing Switches CAS refreshing to on or off. Select your choice. O. Audio Options Displays the AAL2/LES Audio Options submenu, which contains the following commands. Lucent Technologies - 87 - CellPipe™ IAD Series User’s Guide M. Select RX audio cell synchronization mode Sets the RX audio cell synchronization to 1. NONE, 2. STANDARD or 3. OPTIMIZED. Select your choice, and then press ENTER. We highly recommend that you set this mode to NONE. D. Set RX audio cell synchronization delay Sets the RX audio cell synchronization delay, a value in milliseconds. N. Toggle RX audio dejittering seq. no. usage (in STANDARD mode) Switches RX audio cell synchronization packet sequence number use between on and off. S. Toggle TX audio cell seq. no. synchronization with Basic Clock Switches TX audio cell packet sequence number synchronization with the Basic Clock between on and off. Select your choice. P. Set Max. CPS Payload Sets the maximum CPS payload size, a value between 1-45/64 octets (default = 44 octets). Type the maximum CPS payload size, and then press ENTER. The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. U. Toggle User State Control Switches the user state control between on and off. D. Debug Control Displays the AAL2/LES Debug Control submenu, which contains the following commands to set the AAL2/LES debugging options. L. Display Line Status Displays the following information about the active line(s): • • Lucent Technologies Line State - 88 - CellPipe™ IAD Series User’s Guide • • • • • SLIC State Hook State Payload CPE Signal GWY Signal D. Display Debug State/Flags Displays the following information about the active debug state and flags: • Debugging – ENABLED or DISABLED. • Flags: o Globals (DT/PCHES) o o o o o o Timers CAS Signaling WAN audio (to POTS) POTS audio (to WAN) POTS hook state Call processing state C. Control Debug (Enable/Disable) Enables and disables debugging. S. Set Debug Flags Enables all AAL2/LES debugging flags or sets values for the following debug flags: • Globals (DT/PCHES) • Timers • CAS Signaling • WAN audio (to POTS) • POTS audio (to WAN) • POTS hook state • Call processing state The CellPipe IADs display a default or last-used value in parentheses to the left of the command prompt. To accept this value, press ENTER. Your settings display in the D. Display Debug State/Flags command. Select your choice. Lucent Technologies - 89 - CellPipe™ IAD Series User’s Guide S. Statistics Displays the AAL2/LES Statistics submenu, which contains the following commands to display information about Audio, CAS and Alarm statistics. A. Display ALL Statistics Displays the following statistical information: • Line • Tx • o o o o Audio CAS Dropped Alarm o o o o Audio CAS Dropped Alarm Rx B. Display Basic (Audio/CAS/Alarm) Statistics Displays the following statistical information: • Line • Tx • Lucent Technologies o o o o Audio CAS Dropped Alarm o o o o Audio CAS Dropped Alarm Rx - 90 - CellPipe™ IAD Series User’s Guide E. Display Basic and Extra Statistics Displays the following statistical information: • Line • Tx • o o o o Audio CAS Dropped Alarm o o o o Audio CAS Dropped Alarm Rx C. Clear Statistics Clears all statistics. Select your choice. Lucent Technologies - 91 - CellPipe™ IAD Series User’s Guide $GPLQLVWUDWLRQ This chapter provides information about: CellPipe IAD security Changing the primary and secondary IP addresses and encryption keys for a Remote Authentication Dial-In User Services (RADIUS) server. Configuring the Simple Network Management Protocol (SNMP) Upgrading software. For more information on the menus, submenus and commands in this chapter, see the Menu interface chapter. Security The CellPipe IADs provide multilevel security using a single User ID and password, which you can set at the following levels: User NetMan – Network Administrator Supervisor The following table lists the default values for both the User IDs and passwords: Access Level User Network Administrator Supervisor User ID <Enter> NetMan Supervisor Password <Enter> <Enter> supervisor The User IDs and passwords are case-sensitive and can contain up to 17 alphanumeric characters – no spaces. You can change the password at each access level, but the CellPipe IADs can only store one password at each access level at one time. You can only change the User ID at the User level. Menus, submenus, and commands that display on the Main Menu depend on your log on access level. For example, access level User displays the fewest number of options. Lucent Technologies - 92 - CellPipe™ IAD Series User’s Guide Changing the User ID To change the User ID: 1. On the Main Menu, select Configure Login. The Password Configuration Menu displays. ******************************************* * Password Configuration Menu * ******************************************* 1. Change User ID 2. Change User Password 3. Change NetMan Password 4. Change Supervisor Password 5. Change Primary RADIUS Server Address 6. Change Primary RADIUS Encryption Secret 7. Change Secondary RADIUS Server Address 8. Change Secondary RADIUS Encryption Secret 9. Display RADIUS Configuration 2. Select Change User ID. The following message displays. Enter new User ID (up to 17 characters) > 3. Type the new User ID, and then press ENTER. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Changing the Password Although you can use the same password for all access levels, we recommend that you use a different one for each level. The following table lists the privileges for each level: Access level User Network Administrator Supervisor Lucent Technologies - 93 - Menu access level User NetMan and User All CellPipe™ IAD Series User’s Guide To change the password: 1. On the Main Menu, select Configure Login. The Password Configuration Menu displays. ******************************************* * Password Configuration Menu * ******************************************* 1. Change User ID 2. Change User Password 3. Change NetMan Password 4. Change Supervisor Password 5. Change Primary RADIUS Server Address 6. Change Primary RADIUS Encryption Secret 7. Change Secondary RADIUS Server Address 8. Change Secondary RADIUS Encryption Secret 9. Display RADIUS Configuration 2. Select Change User Password, Change NetMan Password or Change Supervisor Password. The following message displays. Enter new Password (up to 17 characters) > 3. Type the new password, and then press ENTER. 4. Retype the new password, and then press ENTER. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. RADIUS server You can set the following options to use the RADIUS server to determine the validity of unknown User ID/password pairs: Change the primary or secondary RADIUS Server Address Change the primary or secondary RADIUS Encryption Secret Display RADIUS Configuration Lucent Technologies - 94 - CellPipe™ IAD Series User’s Guide You must have a functional RADIUS server to use this feature. For more information on RADIUS servers, see RFC 2865. If you configure a RADIUS server, you must use a RADIUSauthenticated User ID/password for telnet access. If the RADIUS server goes down, telnet access will not work. Changing the RADIUS server address To change the primary or secondary RADIUS server address: 1. On the Main Menu, select Configure Login. The Password Configuration Menu displays. ******************************************* * Password Configuration Menu * ******************************************* 1. Change User ID 2. Change User Password 3. Change NetMan Password 4. Change Supervisor Password 5. Change Primary RADIUS Server Address 6. Change Primary RADIUS Encryption Secret 7. Change Secondary RADIUS Server Address 8. Change Secondary RADIUS Encryption Secret 9. Display RADIUS Configuration 2. Select Change Primary RADIUS Server Address or Change Secondary RADIUS Server Address. The following message displays. Primary/Secondary RADIUS Server is currently: Enter new Primary/Secondary RADIUS Server as either an IP address or name > 3. Type the new address in one of the following formats, and then press ENTER: IP address Fully-qualified host and domain names (for example: radius.lucent.com - maximum 42 bytes) If you enter host and domain names, you must configure the DNS client. For more information, see the Configure_DNS_client section earlier in this chapter. Lucent Technologies - 95 - CellPipe™ IAD Series User’s Guide You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Changing the RADIUS encryption secret To change the primary or secondary RADIUS encryption key: 1. On the Main Menu, select Configure Login. The Password Configuration Menu displays. ******************************************* * Password Configuration Menu * ******************************************* 1. Change User ID 2. Change User Password 3. Change NetMan Password 4. Change Supervisor Password 5. Change Primary RADIUS Server Address 6. Change Primary RADIUS Encryption Secret 7. Change Secondary RADIUS Server Address 8. Change Secondary RADIUS Encryption Secret 9. Display RADIUS Configuration 2. Select Change Primary RADIUS Encryption Secret or Change Secondary RADIUS Encryption Secret. The following message displays. Primary/Secondary RADIUS Encryption Secret is currently: Enter new Primary/Secondary RADIUS Encryption Secret 3. Type the new encryption key, and then press ENTER. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Displaying the RADIUS configuration To display the RADIUS server configuration: 5. On the Main Menu, select Configure Login. Lucent Technologies - 96 - CellPipe™ IAD Series User’s Guide The Password Configuration Menu displays. ******************************************* * Password Configuration Menu * ******************************************* 1. Change User ID 2. Change User Password 3. Change NetMan Password 4. Change Supervisor Password 5. Change Primary RADIUS Server Address 6. Change Primary RADIUS Encryption Secret 7. Change Secondary RADIUS Server Address 8. Change Secondary RADIUS Encryption Secret 9. Display RADIUS Configuration 6. Select Display RADIUS Configuration. The following information displays. Primary RADIUS Server: Primary RADIUS Secret: Secondary RADIUS Server: Secondary RADIUS Secret: Configuring SNMP You can use the Simple Network Management Protocol (SNMP) to remotely manage the CellPipe IADs. The CellPipe IADs currently support the following SNMP options: Enables and disables SNMP Configure System Contact Configure System Name Configure System Location Configure SNMP Community Configure SNMP Trap Host IP Address For more information on the SNMP options, see the Menu_interface chapter. Lucent Technologies - 97 - CellPipe™ IAD Series User’s Guide Enabling/disabling SNMP To enable or disable SNMP: 1. On the Main Menu, select Configure SNMP. The SNMP Configuration Menu displays. ***************************************** * SNMP Configuration Menu * ***************************************** E. Enable/Disable SNMP P. Configure System Contact N. Configure System Name L. Configure System Location C. Configure SNMP Community T. Configure SNMP Trap Host IP Address 2. Select Enable/Disable SNMP. 3. Do one of the following: To enable SNMP, type E. To disable SNMP, type D. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring the System Contact To configure the system contact: 1. On the Main Menu, select Configure SNMP. The SNMP Configuration Menu displays. ***************************************** * SNMP Configuration Menu * ***************************************** E. Enable/Disable SNMP P. Configure System Contact N. Configure System Name L. Configure System Location C. Configure SNMP Community T. Configure SNMP Trap Host IP Address Lucent Technologies - 98 - CellPipe™ IAD Series User’s Guide 2. Select Configure System Contact. The following instructions display on-screen: System Contact is currently: Enter new System Contact > 3. Type the name of the SNMP contact person (maximum = 39 alphanumeric characters) or press ENTER to accept the default value that displays. The system contact name is not case-sensitive. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring the System Name To configure the system contact: 1. On the Main Menu, select Configure SNMP. The SNMP Configuration Menu displays. ***************************************** * SNMP Configuration Menu * ***************************************** E. Enable/Disable SNMP P. Configure System Contact N. Configure System Name L. Configure System Location C. Configure SNMP Community T. Configure SNMP Trap Host IP Address 2. Select Configure System Name. The following instructions display on-screen: System Description is currently: Enter new System Description > 3. Type the name of the SNMP host server (maximum = 39 alphanumeric characters) or press ENTER to accept the default value that displays. The system name is not case-sensitive. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 99 - CellPipe™ IAD Series User’s Guide Configuring the System Location To configure the system location: 1. On the Main Menu, select Configure SNMP. The SNMP Configuration Menu displays. ***************************************** * SNMP Configuration Menu * ***************************************** E. Enable/Disable SNMP P. Configure System Contact N. Configure System Name L. Configure System Location C. Configure SNMP Community T. Configure SNMP Trap Host IP Address 2. Select Configure System Location. The following instructions display on-screen: System Location is currently: Enter new System Location > 3. Type the SNMP server location or press ENTER to accept the default value that displays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring the System Community The value that you set must match the write community name of the SNMP host to enable the SNMP Set operation. If you enable SNMP and the read-write Community Name is null, SNMP goes into read-only mode with a Community Name of "public". Lucent Technologies - 100 - CellPipe™ IAD Series User’s Guide To configure the system community: 1. On the Main Menu, select Configure SNMP. The SNMP Configuration Menu displays. ***************************************** * SNMP Configuration Menu * ***************************************** E. Enable/Disable SNMP P. Configure System Contact N. Configure System Name L. Configure System Location C. Configure SNMP Community T. Configure SNMP Trap Host IP Address 2. Select Configure SNMP Community. The following instructions display on-screen: SNMP Community is currently: Enter new SNMP Community > 3. Type the name of the SNMP community to which your system belongs or press ENTER to accept the default value that displays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring the SNMP Trap Host IP Address To configure the SNMP Trap Host IP Address: 1. On the Main Menu, select Configure SNMP. The SNMP Configuration Menu displays. ***************************************** * SNMP Configuration Menu * ***************************************** E. Enable/Disable SNMP P. Configure System Contact N. Configure System Name L. Configure System Location C. Configure SNMP Community T. Configure SNMP Trap Host IP Address Lucent Technologies - 101 - CellPipe™ IAD Series User’s Guide 2. Select Configure SNMP Trap Host IP Address. The following instructions display on-screen: Current SNMP Trap Host IP Address = 0.0.0.0 Enter new SNMP Trap Host IP address: 3. Type the IP address of the system setup for trap operations or press ENTER to accept the default value (0.0.0.0) that displays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. 4. Press ESC, and then select Reset System. Upgrading the system You can use the Trivial File Transfer Protocol (TFTP) to upgrade the CellPipe IAD software. To use TFTP to upgrade, you must properly configure both the CellPipe IAD and the computer that contains the TFTP Server program, a program that you must purchase separately. Before you can run TFTP, you must configure the IP address of the Ethernet, T1/E1 or SDSL Interfaces. For more information, see the Getting started chapter. Configuring the TFTP Server To configure the TFTP Server: Copy the following files to a directory on your PC, in the path that the TFTP Server will use to send files to the CellPipe IAD: acos.bin release.dat boot.bin callcontrol.vg cucomcpe.vg tbcpe.vg mgcp_rg.vg aal2.vg For more information, see your TFTP Server documentation. Lucent Technologies - 102 - CellPipe™ IAD Series User’s Guide Using TFTP To upgrade the CellPipe IAD software using TFTP: 1. Log on to the menu interface. The Main Menu displays. ***************************************** * Main Menu * ***************************************** 1. Reports Menu 2. Configure IP Router 3. Configure Bridge 5. Configure WAN 6. Configure LAN 7. Configure SNMP 8. Configure Login 9. System Utilities D. Configure DHCP Server N. Configure NAT T. Derived Timing Z. Diagnostics Menu C. Command Line Interface R. Reset System P. VoicePath Configure For more information, see the Getting started chapter. 2. On the Main Menu, select System Utilities. The Utilities Menu displays. ******************************************* * Utilities Menu * ******************************************* P. Ping Utility T. Trace Route Z. Configure Console Baud Rate V. Configure Console Timeout R. Hard Reset or Reload ACOS from FLASH D. Set System Defaults W. Save System Settings as Defaults Lucent Technologies - 103 - CellPipe™ IAD Series User’s Guide F. File System Menu X. File Transfer Menu 3. Select File Transfer Menu. The File Transfer Menu displays. ****************************************** * File Transfer Menu * ****************************************** B. Load Boot ROM O. Update ACOS [acos.bin] X. Update Entire System A. File Transfer Utilities 4. Select Update Entire System. The File Transfer Method submenu displays. ***************************************** * File Transfer Method * ***************************************** 1. Receive via TFTP 2. Receive via XMODEM 5. Select Receive via TFTP. 6. Type the IP address of the TFTP Server, and then press ENTER. You can also upgrade the CellPipe IAD software using TFTP via Telnet. Using Telnet To upgrade the CellPipe IAD software using TFTP via Telnet: 1. Use a Telnet program to connect to the CellPipe IAD. For more information, see the Getting started chapter. 2. Follow the procedures described in the Using TFTP section. Lucent Technologies - 104 - CellPipe™ IAD Series User’s Guide Verifying the download To verify that the file downloaded successfully: 1. On the Main Menu, select System Utilities. The Utilities Menu displays. ******************************************* * Utilities Menu * ******************************************* P. Ping Utility T. Trace Route Z. Configure Console Baud Rate V. Configure Console Timeout R. Hard Reset or Reload ACOS from FLASH D. Set System Defaults W. Save System Settings as Defaults F. File System Menu X. File Transfer Menu 2. Select File System Menu. The File System Menu displays. ***************************************** * File System Menu ***************************************** D. Directory of all files C. Copy file R. Rename File X. Remove File by name F. Format File System drive S. Space left in File System 3. Select Directory of all files. A list of all installed files displays. Lucent Technologies - 105 - CellPipe™ IAD Series User’s Guide Upgrading ACOS You can use the Trivial File Transfer Protocol (TFTP) to upgrade the CellPipe IAD software. To use TFTP to upgrade, you must properly configure both the CellPipe IAD and the computer that contains the TFTP Server program, a program that you must purchase separately. Before you can run TFTP, you must configure the IP address of the Ethernet, T1/E1 or SDSL Interfaces. For more information, see the Getting started chapter. Configuring the TFTP Server To configure the TFTP Server: Copy the CellPipe IAD software to a file named ACOS.bin in the path that the TFTP Server will use to send files to the CellPipe IAD. For more information, see your TFTP Server documentation. Using TFTP To upgrade the CellPipe IAD software using TFTP: 1. Log on to the menu interface. The Main Menu displays. ***************************************** * Main Menu * ***************************************** 1. Reports Menu 2. Configure IP Router 3. Configure Bridge 5. Configure WAN 6. Configure LAN 7. Configure SNMP 8. Configure Login 9. System Utilities D. Configure DHCP Server N. Configure NAT T. Derived Timing Z. Diagnostics Menu C. Command Line Interface Lucent Technologies - 106 - CellPipe™ IAD Series User’s Guide R. Reset System P. VoicePath Configure For more information, see the Getting started chapter. 2. On the Main Menu, select System Utilities. The Utilities Menu displays. ******************************************* * Utilities Menu * ******************************************* P. Ping Utility T. Trace Route Z. Configure Console Baud Rate V. Configure Console Timeout R. Hard Reset or Reload ACOS from FLASH D. Set System Defaults W. Save System Settings as Defaults 3. 4. 5. 6. Lucent Technologies F. File System Menu X. File Transfer Menu Select File Transfer Menu. The File Transfer Menu displays. ****************************************** * File Transfer Menu * ****************************************** B. Load Boot ROM O. Update ACOS [acos.bin] X. Update Entire System A. File Transfer Utilities Select Update ACOS [acos.bin]. The File Transfer Method submenu displays. ***************************************** * File Transfer Method * ***************************************** 1. Receive via TFTP 2. Receive via XMODEM Select Receive via TFTP. Type the IP address of the TFTP Server, and then press ENTER. - 107 - CellPipe™ IAD Series User’s Guide 7. Type ACOS.bin, and then press ENTER. It takes up to 2 minutes to download the file, and up to 30 seconds to save it to Flash memory. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IAD, see the Getting started chapter. 8. Press ESC, and then select Reset System. You can also upgrade the CellPipe IAD software using TFTP via Telnet. Using Telnet To upgrade the CellPipe IAD software using TFTP via Telnet: 1. Use a Telnet program to connect to the CellPipe IAD. For more information, see the Getting started chapter. 2. Follow the procedures described in the Using TFTP section. Verifying the download To verify that the file downloaded successfully: 1. On the Main Menu, select System Utilities. The Utilities Menu displays. ******************************************* * Utilities Menu * ******************************************* P. Ping Utility T. Trace Route Z. Configure Console Baud Rate V. Configure Console Timeout R. Hard Reset or Reload ACOS from FLASH D. Set System Defaults W. Save System Settings as Defaults F. File System Menu X. File Transfer Menu Lucent Technologies - 108 - CellPipe™ IAD Series User’s Guide 2. Select File System Menu. The File System Menu displays. ***************************************** * File System Menu ***************************************** D. Directory of all files C. Copy file R. Rename File X. Remove File by name F. Format File System drive S. Space left in File System 3. Select Directory of all files. A list of all installed files displays. Lucent Technologies - 109 - CellPipe™ IAD Series User’s Guide :$1FRQILJXUDWLRQ This chapter details how to configure the CellPipe IADs for both data and voice operation. To do so, you must: Configure the datalink protocol Configure the physical interface ** Configure ATM PVCs and ATM options (Datalink protocol = ATM) Configure Frame Relay DLCIs and Configure Frame Relay options (Datalink protocol = Frame Relay) Configure the voice path ** For the CellPipe IAD 4S/8S, you can also use the Quick Configuration command to configure the physical interface. For more information, see the Quick Configuration section later in this chapter. Voice and data traffic are each carried in their own PVCs (protocol = ATM) or DLCI (protocol = Frame Relay). You can define up to 8 PVCs or DLCIs for voice and data. In the case of a voice circuit, a single PVC or DLCI can carry the voice traffic for all POTS ports on the CellPipe IAD. For more information on the menus, submenus and commands in this chapter, see the Menu interface chapter. Changing the Datalink Protocol To change the datalink protocol: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. ***************************************** * WAN Configuration Menu * ***************************************** 1. Configure Datalink Protocol 2. Configure Physical Interface 3. Configure DLCIs 4. Configure FR Options Lucent Technologies - 110 - CellPipe™ IAD Series User’s Guide 2. Select Configure Datalink Protocol. The WAN Datalink Protocol Configuration Menu displays. ******************************************* * WAN Datalink Protocol Configuration Menu* ******************************************* Current DataLink Protocol : Frame Relay 6. ATM 7. Frame Relay 3. Select your choice. If you select Frame Relay, you must also add or modify a DLCI and then set the Frame Relay options. For more information, see the Configuring Frame Relay DLCIs and Configuring Frame Relay options sections later in this chapter, respectively. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. You can now configure the physical interface. Configuring the Physical Interface The following are the WAN interfaces that you can configure: SDSL (CellPipe IAD 4S/8S) T1 or E1 (CellPipe IAD 8T) ADSL (CellPipe IAD 4A) Lucent Technologies - 111 - CellPipe™ IAD Series User’s Guide Configuring the SDSL Interface To configure the SDSL interface: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. ***************************************** * WAN Configuration Menu * ***************************************** Configuring SDSL 0. Quick Configuration 1. Configure Datalink Protocol 2. Configure Physical Interface 2. Select Configure Physical Interface. The SDSL Configuration submenu displays. ******************************************* * SDSL Configuration * ******************************************* Current SDSL configuration: CPE, AUTO Cycle, Bit Order: Sign.Mag, SPEED = 1152 Kbps, Conexant AutoBaud: Disabled 1. Toggle SDSL Mode (CO or CPE) 2. Set SDSL Speed to Auto Cycle (Nokia) 3. Set SDSL Speed to Auto Sense (Copper Mountain) 4. Enable/Disable Conexant AutoBaud Mode 5. Set SDSL Sync Delay (Lucent) 6. Set SDSL to AccessLan CPE Mode 7. Set SDSL Speed Manually 8. Restart SDSL Activation Sequence 9. SDSL Interface Mode (Bit Order) A. Enable/Disable SDSL AutoBaud Debug Messages Lucent Technologies - 112 - CellPipe™ IAD Series User’s Guide D. Enable/Disable SDSL Debug Messages Y. Enable/Disable Sync Msgs P. Preactivation Debug Mode 3. Select your choice. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring the T1 interface To configure the T1 interface: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. ***************************************** * WAN Configuration Menu * ***************************************** Configuring T1/E1 1. Configure Datalink Protocol 2. Configure Physical Interface 3. Configure PVCs 4. Configure ATM Options 2. Select Configure Physical Interface. The T1 Configuration Menu displays. ******************************************* * T1 Configuration Menu * ******************************************* 1. Select Frame Mode (D4 or ESF) 2. Select Line Build Out 3. Enable/Disable B8ZS 6. Configure Transmit Channels 7. Configure Receive Channels 8. Configure Tx Clock Source 9. Change to E1 Mode Lucent Technologies - 113 - CellPipe™ IAD Series User’s Guide 3. Select Select Frame Mode (D4 or ESF). The Select T1 Frame Mode submenu displays. ********************************** * Select T1 Frame Mode * ********************************** T1 Frame Mode Is ESF 1. ESF Frame Mode 2. D4 Frame Mode 4. Select your choice, and the press ESC. The T1 Configuration Menu redisplays. 5. Select Select Line Build Out. The Select Line Build Out submenu displays. ************************************ * Select Line Build Out * ************************************ Line Build Out Is 0 To 133 Feet (0 dB) 1. 2. 3. 4. 5. 6. 7. 8. 0 To 133 Feet (0 dB) 133 To 266 Feet 266 To 399 Feet 399 To 533 Feet 533 To 655 Feet -7.5 dB -15 dB -22.5 dB 6. Select the line build out that corresponds to the T1 span length in use, and then press ESC. The T1 Configuration Menu redisplays. 7. Select Enable/Disable B8ZS, and then do one of the following: To enable B8ZS, type Y. To disable B8ZS, type N. The T1 Configuration Menu redisplays. Lucent Technologies - 114 - CellPipe™ IAD Series User’s Guide 8. Select Configure Transmit Channels. The Channel Configuration Menu displays. ************************************ * Channel Configuration Menu * ************************************ 1. Enable All Channels 2. Disable All Channels 3. Select Individual Channels 4. Select Channel Range 9. Select the channel in which to send the T1. The T1 Configuration Menu redisplays. 10. Select Configure Receive Channels. The Channel Configuration Menu redisplays. 11. Select the channel in which to receive T1. The T1 Configuration Menu redisplays. 12. Select Configure Tx Clock Source. The Select Tx Clock Source submenu displays. ********************************** * Select Tx Clock Source * ********************************** Tx Clock is derived from Rx clock (Slave Mode). 1. External (Slave Mode) 2. Internal (Master Mode) 13. Select your choice, and then press ESC. The T1 Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 115 - CellPipe™ IAD Series User’s Guide Switching from the T1 and E1 interfaces To switch from the T1 and E1 interfaces: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. ***************************************** * WAN Configuration Menu * ***************************************** Configuring T1/E1 1. Configure Datalink Protocol 2. Configure Physical Interface 3. Configure PVCs 4. Configure ATM Options 2. Select Configure Physical Interface. The T1 Configuration Menu or E1 Configuration Menu displays. 3. Do one of the following, and then press y: To switch to E1 mode, select Change to E1 Mode. To switch to T1 mode, select Change to T1 Mode. Configuring the E1 interface (Currently the E1 interface is not supported.) To configure the E1 interface: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. ***************************************** * WAN Configuration Menu * ***************************************** Configuring T1/E1 1. 2. 3. 4. Lucent Technologies Configure Configure Configure Configure - 116 - Datalink Protocol Physical Interface PVCs ATM Options CellPipe™ IAD Series User’s Guide 2. Select Configure Physical Interface. The E1 Configuration Menu displays. ****************************************** * E1 Configuration Menu * ****************************************** 1. Select Frame/CRC4 Mode 3. Configure S-Bits 4. Configure Transmit Channels 5. Configure Receive Channels 6. Configure Clock Source 7. Change to T1 Mode 3. Select Select Frame/CRC4 Mode. The Select E1 Frame Mode submenu displays. ************************************* * Select E1 Frame Mode * ************************************* E1 Frame Mode 1. 2. 3. 4. = FAS FAS FAS (CRC4 Enabled) Multi-Frame CAS Multi-Frame CAS (CRC4 Enabled) 4. Select your choice, and the press ESC. The E1 Configuration Menu redisplays. 5. Select Configure S-Bits. The Configure S-Bits Menu displays. ******************************************* * Configure S-Bits Menu * ******************************************* Current S-Bit Configuration: Sa4 Bit Sa5 Bit Sa6 Bit Sa7 Bit Sa8 Bit Lucent Technologies - 117 - = = = = = Cleared Cleared Cleared Cleared Cleared CellPipe™ IAD Series User’s Guide 2. 3. 4. 5. 6. Toggle Toggle Toggle Toggle Toggle Sa4 Sa5 Sa6 Sa7 Sa8 Bit Bit Bit Bit Bit 6. Select the line build out that corresponds to the T1 span length in use, and then press ESC. The E1 Configuration Menu redisplays. 7. Select Configure Transmit Channels. The Channel Configuration Menu displays. ************************************ * Channel Configuration Menu * ************************************ 1. Enable All Channels 2. Disable All Channels 3. Select Individual Channels 4. Select Channel Range 8. Select the channel in which to send the E1. The E1 Configuration Menu redisplays. 9. Select Configure Receive Channels. The Channel Configuration Menu redisplays. 10. Select the channel in which to receive E1. The E1 Configuration Menu redisplays. 11. Select Configure Clock Source. The Select Tx Clock Source submenu displays. ********************************** * Select Tx Clock Source * ********************************** Tx Clock is derived from Rx clock (Slave Mode). 1. External (Slave Mode) 2. Internal (Master Mode) Lucent Technologies - 118 - CellPipe™ IAD Series User’s Guide 12. Select your choice, and then press ESC. The E1 Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring the ADSL interface To configure the ADSL interface: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. ***************************************** * WAN Configuration Menu * ***************************************** Configuring G7070 ADSL ATU-R 1. Configure Datalink Protocol 2. Configure Physical Interface 3. Configure DLCIs 4. Configure FR Options 2. Select Configure Physical Interface. The G7070 ADSL ATU-R Configuration submenu displays. ******************************************* * G7070 ADSL ATU-R Configuration * ******************************************* 1. Set ADSL Standard d. Enable/Disable ADSL Debug Messages Lucent Technologies - 119 - CellPipe™ IAD Series User’s Guide 3. Select Set ADSL Standard. The ADSL Standard to use for Startup submenu displays. ******************************************* * ADSL Standard to use for Startup * ******************************************* Current ADSL Standard : Multi-Mode 1. 2. 3. 4. 5. 6. 7. T1.413 G.LITE G.DMT Alcatel 1.4 Multi-Mode ADI Alcatel 4. Select your choice, and then press ESC. The G7070 ADSL ATU-R Configuration submenu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Quick Configuration The CellPipe IAD 4S/8S contains a number of predefined configurations. The Quick Configuration command only displays on the CellPipe IAD 4S/8S. Lucent Technologies - 120 - CellPipe™ IAD Series User’s Guide To use one of the predefined configurations: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. ***************************************** * WAN Configuration Menu * ***************************************** Configuring SDSL 0. Quick Configuration 1. Configure Datalink Protocol 2. Configure Physical Interface 2. Select Quick Configuration. The Quick Configuration submenu displays. ***************************************** * Quick Configuration * ***************************************** ** System will reset after changing configuration ** Current configuration: Differ from listed configurations 1. Lucent Stinger (Conexant Autobaud, Payload Scrambling) 2. Nokia (Auto Cycle) 3. Copper Mountain (Auto Sense) 4. Paradyne (Framed 784kbps, Payload Scrambling) 5. AccessLan CPE 6. Nortel IMAS 7. ATM (Unframed, 1152kbps fixed) 8. Frame Relay (784kbps fixed) 3. Select the DSLAM to which the CellPipe IAD is connecting. The CellPipe IAD automatically restarts. Lucent Technologies - 121 - CellPipe™ IAD Series User’s Guide 4. Log back on to the CellPipe IAD. For more information, see the Getting started chapter. You can now configure PVCs or DLCIs. However, you must first change the datalink protocol to ATM (PVCs) or Frame Relay (DLCIs). Configuring ATM PVCs The CellPipe IADs contain commands to allow you to configure ATM PVCs: Add New PVC Modify Existing PVC Delete PVC Show Current PVCs You can configure up to 8 PVCs on the CellPipe IADs. Adding a PVC To add a PVC: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure PVCs. The ATM PVC Config Menu displays. ***************************************** * ATM PVC Config Menu * ***************************************** 1. Add New PVC 2. Modify Existing PVC 3. Delete PVC 4. Show Current PVCs 3. Select Add New PVC. 4. Type a VPI between 0-255 (default = 0), and then press ENTER. Lucent Technologies - 122 - CellPipe™ IAD Series User’s Guide 5. Type a VCI between 32 – 65535 (default = 38 – data or 39 – voice), and then press ENTER. The ATM Encapsulation Configuration submenu displays. ***************************************** * ATM Encapsulation Configuration * ***************************************** Current Encapsulation : NONE 1. AAL5 (None) 2. AAL0 (None) 3. Proprietary Voice 4. RFC 1483 (using VC Muxing) 5. RFC 1483 (with LLC Encapsulation) 6. RFC 2364 (PPPoATM with LLC Encapsulation) 7. RFC 2364 (PPPoATM using VC Muxing) 6. Select the encapsulation you want to configure. If you select RFC 2364 (PPPoATM with LLC Encapsulation) or RFC 2364 (PPPoATM using VC Muxing), follow the on-screen messages to set the PPP authorization type. Once complete, continue with step 7. The ATM Service Category Configuration submenu displays. ***************************************** * ATM Service Category Configuration * ***************************************** 1. CBR 2. UBR 7. Do one of the following: Select CBR for high priority data. Select UBR for low priority data. Follow the on-screen messages to set the Peak Cell Rate (PCR) value. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 123 - CellPipe™ IAD Series User’s Guide Modifying a PVC To modify a PVC 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure PVCs. The ATM PVC Config Menu displays. ***************************************** * ATM PVC Config Menu * ***************************************** 1. Add New PVC 2. Modify Existing PVC 3. Delete PVC 4. Show Current PVCs 3. Select Modify Existing PVC. 4. Type the port number to modify, and then press ENTER. 5. Type a VPI between 0-255 (default = 0), and then press ENTER. 6. Type a VCI between 32 – 65535 (default = 38 – data or 39 – voice), and then press ENTER. The ATM Encapsulation Configuration submenu displays. ***************************************** * ATM Encapsulation Configuration * ***************************************** Current Encapsulation : NONE 1. AAL5 (None) 2. AAL0 (None) 3. Proprietary Voice 4. RFC 1483 (using VC Muxing) 5. RFC 1483 (with LLC Encapsulation) 6. RFC 2364 (PPPoATM with LLC Encapsulation) 7. RFC 2364 (PPPoATM using VC Muxing) 7. Select the encapsulation you want to configure. If you select RFC 2364 (PPPoATM with LLC Encapsulation) or RFC 2364 (PPPoATM using VC Muxing), follow the on-screen messages to set the PPP authorization type. Once complete, continue with step 8. Lucent Technologies - 124 - CellPipe™ IAD Series User’s Guide The ATM Service Category Configuration submenu displays. ***************************************** * ATM Service Category Configuration * ***************************************** 1. CBR 2. UBR 8. Do one of the following: Select CBR for high priority data. Select UBR for low priority data. 9. Follow the on-screen messages to set the Peak Cell Rate (PCR) value. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Deleting a PVC To delete a PVC: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure PVCs. The ATM PVC Config Menu displays. ***************************************** * ATM PVC Config Menu * ***************************************** 1. Add New PVC 2. Modify Existing PVC 3. Delete PVC 4. Show Current PVCs 3. Select Delete PVC. 4. Type the port number to delete, and then press ENTER. 5. Do one of the following: To delete the PVC, type y. To cancel the deletion, type n. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 125 - CellPipe™ IAD Series User’s Guide Configuring ATM options The CellPipe IADs contain commands to allow you to configure or display the following ATM options: Payload Scrambling F4 OAM VPI F4 OAM Type F4 OAM Configuration OAM Loopback Empty Cells Configuring Payload Scrambling You must enable payload scrambling (default = disabled) for the CellPipe IAD to talk to a DSLAM that uses payload scrambling. To enable payload scrambling: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure ATM Options. The ATM Configuration Menu displays. ***************************************** * ATM Configuration Menu * ***************************************** 1. Configure Payload Scrambling 2. Configure F4 OAM VPI 3. Configure F4 OAM Type 4. Display F4 OAM Configuration 5. Send OAM Loopback 6. Configure EmptyCells 3. Select Configure Payload Scrambling, and then do one of the following: To enable payload scrambling, type E. To disable payload scrambling, type D. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 126 - CellPipe™ IAD Series User’s Guide Configuring the F4 OAM Cell To configure the F4 OAM Cell 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure ATM Options. The ATM Configuration Menu displays. ***************************************** * ATM Configuration Menu * ***************************************** 1. Configure Payload Scrambling 2. Configure F4 OAM VPI 3. Configure F4 OAM Type 4. Display F4 OAM Configuration 5. Send OAM Loopback 6. Configure EmptyCells 3. Select Configure F4 OAM VPI, and then type the VPI. This value must match one of the WAN PVCS. For more information, see the Configuring_ATM_PVCs section earlier in this chapter. The ATM Configuration Menu redisplays. 4. Select Configure F4 OAM Type. The F4 OAM Type Configuration Menu displays. ******************************************* * F4 OAM Type Configuration Menu * ******************************************* 0. None 4. F4 End to end OAM 5. Select your choice. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Sending OAM Loopback To send an OAM Loopback: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. Lucent Technologies - 127 - CellPipe™ IAD Series User’s Guide 2. Select Configure ATM Options. The ATM Configuration Menu displays. ***************************************** * ATM Configuration Menu * ***************************************** 1. Configure Payload Scrambling 2. Configure F4 OAM VPI 3. Configure F4 OAM Type 4. Display F4 OAM Configuration 5. Send OAM Loopback 6. Configure EmptyCells 3. Select Send OAM Loopback. A list of all configured F4 OAM ports and its VPI value displays. 4. Select the port on which to send the OAM Loopback, and then press ENTER. Configuring Empty Cells To configure empty cells: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure ATM Options. The ATM Configuration Menu displays. ***************************************** * ATM Configuration Menu * ***************************************** 1. Configure Payload Scrambling 2. Configure F4 OAM VPI 3. Configure F4 OAM Type 4. Display F4 OAM Configuration 5. Send OAM Loopback 6. Configure EmptyCells 3. Select Configure EmptyCells. The following instructions display on-screen: Empty Cells are currently IDLE Enter 1 for IDLE cells or 2 for UNASSIGNED cells: Lucent Technologies - 128 - CellPipe™ IAD Series User’s Guide 4. Select your choice. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring Frame Relay DLCIs The CellPipe IADs contain commands to allow you to configure Frame Relay DLCIs: Add New DLCI Modify Existing DLCI Delete DLCI Show Current DLCIs You can configure up to 8 DLCIs on the CellPipe IADs. Adding a DLCI To add a DLCI: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure DLCIs. The FR DLCI Config Menu displays. ***************************************** * FR DLCI Config Menu * ***************************************** 1. Add New DLCI 2. Modify Existing DLCI 3. Delete DLCI 4. Show Current DLCIs 3. Select Add New DLCI. 4. Type a DLCI value between 16-1023 (defaults = 32 – data and 33 – voice), and then press ENTER. Lucent Technologies - 129 - CellPipe™ IAD Series User’s Guide The FR Encapsulation Configuration submenu displays. ***************************************** * FR Encapsulation Configuration * ***************************************** Current Encapsulation : None 1. RAW (No Encapsulation) 2. Proprietary Voice DLCI 3. RFC 1490 4. ATM RFC 1483 (Tunneling) 5. Select the encapsulation method to use. The FR DLCI Options submenu displays. ***************************************** * FR DLCI Options * ***************************************** 1. Configure Transmit CIR 2. Configure Receive CIR 3. Configure FRF.12 Fragmentation 6. Do one of the following: Select Configure Transmit CIR or Configure Receive CIR, and then follow the on-screen messages to set: Committed burst size (Bc) Circuit throughput Excess burst size (Be) Select Configure FRF .12 Fragmentation, and then follow the on-screen messages to: Enable/Disable End-to-End FRF .12 Set Fragment Size You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 130 - CellPipe™ IAD Series User’s Guide Modifying a DLCI To modify a DLCI: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure DLCIs. The FR DLCI Config Menu displays. ***************************************** * FR DLCI Config Menu * ***************************************** 1. Add New DLCI 2. Modify Existing DLCI 3. Delete DLCI 4. Show Current DLCIs 3. Select Modify Existing DLCI. 4. Type the port number to change, and then press ENTER. 5. Type the DLCI value, and then press ENTER. The FR Encapsulation Configuration submenu displays. ***************************************** * FR Encapsulation Configuration * ***************************************** Current Encapsulation : None 1. RAW (No Encapsulation) 2. Proprietary Voice DLCI 3. RFC 1490 4. ATM RFC 1483 (Tunneling) 6. Select the encapsulation method to use. The FR DLCI Options submenu displays. ***************************************** * FR DLCI Options * ***************************************** 1. Configure Transmit CIR 2. Configure Receive CIR 3. Configure FRF.12 Fragmentation Lucent Technologies - 131 - CellPipe™ IAD Series User’s Guide 7. Do one of the following: Select Configure Transmit CIR or Configure Receive CIR, and then follow the on-screen messages to set: Committed burst size (Bc) Circuit throughput Excess burst size (Be) Select Configure FRF .12 Fragmentation, and then follow the on-screen messages to: Enable/Disable End-to-End FRF .12 Set Fragment Size You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Deleting a DLCI To delete a DLCI: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure DLCIs. The FR DLCI Config Menu displays. ***************************************** * FR DLCI Config Menu * ***************************************** 1. Add New DLCI 2. Modify Existing DLCI 3. Delete DLCI 4. Show Current DLCIs 3. Select Delete DLCI. 4. Do one of the following: To delete the DLCI configuration, type y. To cancel the deletion, type n. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 132 - CellPipe™ IAD Series User’s Guide Configuring Frame Relay options The CellPipe IADs contain commands to allow you to configure or display the following Frame Relay options: Fragmentation Maintenance Protocol Congestion Parameters Copper Mountain CMCP Configuring fragmentation To configure fragmentation: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure FR Options. The Frame Relay Options submenu displays. ***************************************** * Frame Relay Options * ***************************************** 1. Configure Fragmentation 2. Configure Maintenance Protocol 3. Configure Congestion Parameters 4. Enable/Disable Copper Mountain CMCP (CellZpipe IAD 4S/8S/8T) 3. Select Configure Fragmentation. The FR Fragmentation Configuration submenu displays. ***************************************** * FR Fragmentation Configuration * ***************************************** 1. Configure FRF.12 Fragmentation 2. Configure CopperMountain Fragmentation Lucent Technologies - 133 - CellPipe™ IAD Series User’s Guide Do one of the following: Select Configure FRF.12 Fragmentation. The FR FRF.12 Configuration submenu displays. ************************************* * FR FRF.12 Configuration * ************************************** 1. Enable/Disable FRF.12 2. Enable Automatic Fragment Sizing 3. Set Manual Fragment Size Select your choice, and then follow the on-screen instructions. Select Configure CopperMountain Fragmentation. The FR FRF.12 Configuration submenu displays. ************************************* * FR FRF.12 Configuration * ************************************* 1. Enable/Disable CuMtn Fragmentation 2. Set Real-Time DLCI Select your choice, and then follow the on-screen instructions. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring the maintenance protocol To configure the maintenance protocol: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. Lucent Technologies - 134 - CellPipe™ IAD Series User’s Guide 2. Select Configure FR Options. The Frame Relay Options submenu displays. ***************************************** * Frame Relay Options * ***************************************** 1. Configure Fragmentation 2. Configure Maintenance Protocol 3. Configure Congestion Parameters 4. Enable/Disable Copper Mountain CMCP (CellPipe IAD 4S/8S/8T) 3. Select Configure Maintenance Protocol. The Frame Relay Maintenance Protocol submenu displays. ***************************************** * Frame Relay Maintenance Protocol * ***************************************** 0. None 1. CCITT Q.933 Annex A Network 2. CCITT Q.933 Annex A User 3. CCITT Q.933 Annex A Both 4. ANSI T1.617 Annex D Network 5. ANSI T1.617 Annex D User 6. ANSI T1.617 Annex D Both 7. LMI Network (FRF.1.1) 8. LMI User (FRF.1.1) 9. LMI Both (FRF.1.1) 4. Type the number that corresponds to the protocol on your network, and then press ENTER. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 135 - CellPipe™ IAD Series User’s Guide Configuring the congestion parameters To configure the congestion parameters: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure FR Options. The Frame Relay Options submenu displays. ***************************************** * Frame Relay Options * ***************************************** 1. Configure Fragmentation 2. Configure Maintenance Protocol 3. Configure Congestion Parameters 4. Enable/Disable Copper Mountain CMCP (CellPipe IAD 4S/8S/8T) 3. Select Configure Congestion Parameters. The FR Congestion Configuration submenu displays. ***************************************** * FR Congestion Configuration * ***************************************** 1. Configure Transmit Congestion Parameters 2. Configure Receive Congestion Parameters 4. Do one of the following. Select Configure Transmit Congestion Parameters, and then follow the on-screen messages to set: FECN/BECN condition set size FECN/BECN condition clear size FECN/BECN max number of bytes to store Select Configure Receive Congestion Parameters, and then follow the on-screen messages to: FECN/BECN condition set size FECN/BECN condition clear size FECN/BECN max number of bytes to store Lucent Technologies - 136 - CellPipe™ IAD Series User’s Guide You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Enabling/Disabling Copper Mountain CMCP To enable or disable Copper Mountain CMCP: 1. On the Main Menu, select Configure WAN. The WAN Configuration Menu displays. 2. Select Configure FR Options. The Frame Relay Options submenu displays. ***************************************** * Frame Relay Options * ***************************************** 1. Configure Fragmentation 2. Configure Maintenance Protocol 3. Configure Congestion Parameters 4. Enable/Disable Copper Mountain CMCP (CellPipe IAD 4S/8S/8T) 3. Select Enable/Disable Copper Mountain CMCP. The following instructions display on-screen: CMCP is currently DISABLED Enter E to Enable, D to Disable : 4. Do one of the following: To enable Copper Mountain CMCP, type E. To disable Copper Mountain CMCP, type D. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 137 - CellPipe™ IAD Series User’s Guide Configuring the voice path After you define the voice PVCs and DLCIs, you need to perform the following steps to configure the voice path: Set the jitter delay Set the start mode Set the SLIC control mode Set the ground start on-hook transmission (OHT) mode Set the echo cancellation Set the loop gain Setting the jitter delay When the jitter delay is set, the CellPipe IADs hold the incoming packet data from the WAN voice channel to allow for variance in packet arrival time. The time that you set for the jitter delay depends on the data rate in use – the lower the data rate, the higher the delay. To set the jitter delay 1. On the Main Menu, select VoicePath Configure. The Voice Configuration submenu displays. ***************************************** * Voice Configuration * ***************************************** V. Set Voice Gateway J. Set Jitter Delay D. Display Jitter Delay S. Set Start Mode (Loop Start/Ground Start) T. Set SLIC Control Mode U. Set Compander Mode (u-Law, A-Law) O. Set On Hook Transmission Mode of Ground Start Lines M. Set Debug Mode E. Configure Echo Cancellation Default Settings G. Set Loop Gain C. Set Country Mode (6108, 6504, 6508) Lucent Technologies - 138 - CellPipe™ IAD Series User’s Guide 2. Select Set Jitter Delay. The following instructions display on-screen: Enter number of ms to delay : 3. Type the number of ms to delay, and then press ENTER. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Setting the start mode The type of telephone instrument in use determines how to set the start mode: Loop Start – ideal for regular telephone handsets or key telephone systems (KTS). Ground Start – best for PBXs. To set the start mode: 1. On the Main Menu, select VoicePath Configure. The Voice Configuration submenu displays. ***************************************** * Voice Configuration * ***************************************** V. Set Voice Gateway J. Set Jitter Delay D. Display Jitter Delay S. Set Start Mode (Loop Start/Ground Start) T. Set SLIC Control Mode U. Set Compander Mode (u-Law, A-Law) O. Set On Hook Transmission Mode of Ground Start Lines M. Set Debug Mode E. Configure Echo Cancellation Default Settings G. Set Loop Gain C. Set Country Mode (6108, 6504, 6508) Lucent Technologies - 139 - CellPipe™ IAD Series User’s Guide 2. Select Select Start Mode (Loop Start/Ground Start). The Start Mode Selection submenu displays. ***************************************** * Start Mode Selection * ***************************************** 1. Set All Ports to Loop Start 2. Set All Ports to Ground Start 3. Display Start Mode 4. Configure Individual Port 3. Select your choice, and then press any key. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Setting the SLIC control mode To set the SLIC control mode: 1. On the Main Menu, select VoicePath Configure. The Voice Configuration submenu displays. ***************************************** * Voice Configuration * ***************************************** V. Set Voice Gateway J. Set Jitter Delay D. Display Jitter Delay S. Set Start Mode (Loop Start/Ground Start) T. Set SLIC Control Mode U. Set Compander Mode (u-Law, A-Law) O. Set On Hook Transmission Mode of Ground Start Lines M. Set Debug Mode E. Configure Echo Cancellation Default Settings G. Set Loop Gain C. Set Country Mode (6108, 6504, 6508) Lucent Technologies - 140 - CellPipe™ IAD Series User’s Guide 2. Select Select SLIC Control Mode. The SLIC Control Mode Selection submenu displays. ***************************************** * SLIC Control Mode Selection * ***************************************** Current Control Mode = MANUAL Control Mode A. AUTO Control Mode M. MANUAL Control Mode 3. Select your choice. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Setting the ground start on-hook transmission When you disable the ground start on-hook transmission (factory default), the CellPipe IADs detect an off hook at all times and does not support caller ID. When you enable it there is a two-second window between the first and second ring where it does not detect an off hook; however, it supports caller ID. To set the ground start on hook transmission: 1. On the Main Menu, select VoicePath Configure. The Voice Configuration submenu displays. ***************************************** * Voice Configuration * ***************************************** V. Set Voice Gateway J. Set Jitter Delay D. Display Jitter Delay S. Set Start Mode (Loop Start/Ground Start) T. Set SLIC Control Mode U. Set Compander Mode (u-Law, A-Law) O. Set On Hook Transmission Mode of Ground Start Lines M. Set Debug Mode Lucent Technologies - 141 - CellPipe™ IAD Series User’s Guide E. Configure Echo Cancellation Default Settings G. Set Loop Gain C. Set Country Mode (6108, 6504, 6508) 2. Select Set On Hook Transmission Mode of Ground Start Lines. The Ground Start OHT Mode Selection submenu displays. ***************************************** * Ground Start OHT Mode Selection * ***************************************** On Hook Transmission for a Ground Start Line is DISABLED. E. ENABLE Ground Start On Hook Transmission D. DISABLE Ground Start On Hook Transmission 3. Select your choice. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring Echo Cancellation When you enable echo cancellation, it isolates and filters unwanted digital signals caused by echoes from the main transmitted signal. Echo cancellation automatically disables when the CellPipe IADs detect a FAX or modem signal. At the conclusion of the FAX or modem session, echo cancellation automatically reenables. Lucent Technologies - 142 - CellPipe™ IAD Series User’s Guide To configure echo cancellation: 1. On the Main Menu, select VoicePath Configure. The Voice Configuration submenu displays. ***************************************** * Voice Configuration * ***************************************** V. Set Voice Gateway J. Set Jitter Delay D. Display Jitter Delay S. Set Start Mode (Loop Start/Ground Start) T. Set SLIC Control Mode U. Set Compander Mode (u-Law, A-Law) O. Set On Hook Transmission Mode of Ground Start Lines M. Set Debug Mode E. Configure Echo Cancellation Default Settings G. Set Loop Gain C. Set Country Mode 2. Select Configure Echo Cancellation Default Settings. The Echo Cancellation Default Settings Configure Menu displays. ******************************************* * Echo Cancellation Default Settings Configure Menu * ******************************************* 1. Set Echo Cancellation default setting for all ports 2. Display current Echo Cancellation default settings 3. Configure Echo Cancellation default setting per port 3. Do one of the following, and then follow the on-screen messages: To set the same setting for all ports, select Set Echo Cancellation default setting for all ports. To display the current settings for all ports, select Display current Echo Cancellation default settings. Lucent Technologies - 143 - CellPipe™ IAD Series User’s Guide To set echo cancellation by port, select Configure Echo Cancellation default setting per port. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Setting the loop gain To set the loop gain: 1. On the Main Menu, select VoicePath Configure. The Voice Configuration submenu displays. ***************************************** * Voice Configuration * ***************************************** V. Set Voice Gateway J. Set Jitter Delay D. Display Jitter Delay S. Set Start Mode (Loop Start/Ground Start) T. Set SLIC Control Mode U. Set Compander Mode (u-Law, A-Law) O. Set On Hook Transmission Mode of Ground Start Lines M. Set Debug Mode E. Configure Echo Cancellation Default Settings G. Set Loop Gain C. Set Country Mode 2. Select Set Loop Gain. The Configure Loop Gain Menu displays. ******************************************* * Configure Loop Gain Menu * ******************************************* 1. Set Loop Gain for all ports 2. Display current Loop Gain settings 3. Configure Loop Gain setting per port Lucent Technologies - 144 - CellPipe™ IAD Series User’s Guide 3. Do one of the following, and then follow the on-screen messages: To set the same setting for all ports, select Set Loop Gain for all ports. To set echo cancellation by port, select Configure Loop Gain setting per port. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 145 - CellPipe™ IAD Series User’s Guide 5RXWHUFRQILJXUDWLRQ This chapter describes how to configure the CellPipe IADs as routers. For more information on the menus, submenus and commands in this chapter, see the Menu interface chapter. A router is a network layer device that uses one or more metrics to determine the optimal path along which network traffic should be forwarded. Routers forward packets from one network to another based on network layer information. Occasionally, they are called gateways (although this definition of gateway is becoming increasingly outdated). You must complete the following steps to configure a CellPipe IAD as a router: Configure IP addresses on the LAN and WAN ports Enable the Routing Information Protocol (RIP) poisoned reverse (recommended), add a static route or add a default route Disable bridging globally Disable bridging by port Disable the Spanning Tree Protocol (STP) globally Disable STP by port You can configure the CellPipe IADs as both a router and a bridge – it depends on your application. A router can improve overall efficiency for a complex network, but a bridge provides better speed and flexibility for the overall network. Configuring an IP address To configure the CellPipe IADs as a router, you must assign an IP address to both the LAN and WAN ports – each with different subnet masks. You can assign up to 8 IP addresses on each of the WAN and LAN ports. Lucent Technologies - 146 - CellPipe™ IAD Series User’s Guide To configure an IP address: 1. On the Main Menu, select Configure IP Router. The Router Configuration Menu displays. ***************************************** * Router Configuration Menu * ***************************************** C. Configure Port IP Address U. Unconfigure Port IP Address S. Add/Remove a Static Route R. Enable/Disable RIP V. Configure RIP Version by Port P. Configure RIP Poisoned Reverse by Port N. Configure DNS Client H. Configure DHCP Client L. Configure DHCP Relay T. Configure Telnet Server Port F. Configure IP Filtering D. Display Route Table 2. Select Configure Port IP Address. The following instructions display on-screen: Available Interfaces: 1. G7070 ADSL ATU-R 1. T1/E1 1. SDSL 2. 10/100BaseT Ethernet 0. (Abort) Selection : Interfaces may not display, depending on the IAD in use. 3. Type the number of the port for which you want to configure an IP address. The following message (or one similar) displays: IP interfaces on port 1: IPAddr IPMask ID 0 255.255.255.0 255.255.255.0 Enter connection to configure: Lucent Technologies - 147 - Priority NORMAL CellPipe™ IAD Series User’s Guide 4. Type the ID number of the connection that you want to configure (range = 0-7), and then press ENTER. 5. Type the new IP address, or press ENTER to select the current IP address. The following instructions display on-screen: Current subnet mask = 0.0.0.0 Enter new subnet mask for this interface: 6. Type the new subnet mask address, or press ENTER to select the current subnet mask. The following instructions display on-screen: Select priority Normal/High [N/H] (N): 7. Do one of the following, and then type Y: To give the interface high priority, type H. To give the interface normal priority, type N. The Router Configuration Menu redisplays. 8. Repeat steps 1-6 for each port for which you want to configure an IP address. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Enabling RIP poisoned reverse When you enable RIP, the CellPipe IADs send routing data to other adjacent routers and dynamically learn the associated network topology. For RIP to work, you must enable RIP globally or locally (by port), and then set the RIP version. The order in which you perform the procedures is irrelevant. Enabling RIP poisoned reverse globally To enable RIP poisoned reverse globally: 1. On the Main Menu, select Configure IP Router. The Router Configuration Menu displays. Lucent Technologies - 148 - CellPipe™ IAD Series User’s Guide ***************************************** * Router Configuration Menu * ***************************************** C. Configure Port IP Address U. Unconfigure Port IP Address S. Add/Remove a Static Route R. Enable/Disable RIP V. Configure RIP Version by Port P. Configure RIP Poisoned Reverse by Port N. Configure DNS Client H. Configure DHCP Client L. Configure DHCP Relay T. Configure Telnet Server Port F. Configure IP Filtering D. Display Route Table 2. Select Enable/Disable RIP, and then type E. The Router Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Enabling RIP poisoned reverse by port To enable RIP poisoned reverse by port: 1. On the Main Menu, select Configure IP Router. The Router Configuration Menu displays. ***************************************** * Router Configuration Menu * ***************************************** C. Configure Port IP Address U. Unconfigure Port IP Address S. Add/Remove a Static Route R. Enable/Disable RIP V. Configure RIP Version by Port P. Configure RIP Poisoned Reverse by Port N. Configure DNS Client H. Configure DHCP Client L. Configure DHCP Relay Lucent Technologies - 149 - CellPipe™ IAD Series User’s Guide T. Configure Telnet Server Port F. Configure IP Filtering D. Display Route Table 2. Select Configure RIP Poisoned Reverse by Port. The following instructions display on-screen: Available Interfaces : 1. G7070 ADSL ATU-R 1. T1/E1 1. SDSL 2. 10/100BaseT Ethernet 0. (Abort) Selection : Interfaces may not display, depending on the IAD in use. 3. Type the number of the port for which you want to enable poisoned reverse. The following instructions display on-screen: RIP Poisoned Reverse for Slot 1, Port 1 is currently DISABLED Enter E to Enable, D to Disable : 4. Type E. The Router Configuration Menu redisplays. 5. Repeat steps 1-3 for each port for which you want to enable RIP poisoned reverse. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 150 - CellPipe™ IAD Series User’s Guide Setting the RIP version To set the RIP version: 1. On the Main Menu, select Configure IP Router. The Router Configuration Menu displays. ***************************************** * Router Configuration Menu * ***************************************** C. Configure Port IP Address U. Unconfigure Port IP Address S. Add/Remove a Static Route R. Enable/Disable RIP V. Configure RIP Version by Port P. N. H. L. T. F. D. Configure RIP Poisoned Reverse by Port Configure DNS Client Configure DHCP Client Configure DHCP Relay Configure Telnet Server Port Configure IP Filtering Display Route Table 2. Select Configure RIP Version by Port. The following instructions display on-screen: Available Interfaces : 1. G7070 ADSL ATU-R 1. T1/E1 1. SDSL 2. 10/100BaseT Ethernet 0. (Abort) Selection : Interfaces may not display, depending on the IAD in use. Lucent Technologies - 151 - CellPipe™ IAD Series User’s Guide 3. Type the number of the port for which you want to configure the RIP poisoned reverse version. The following instructions display on-screen: Enter RIP Version for Port 1 0. Disabled 1. Version 1 Broadcast 2. Version 2 Broadcast 3. Version 2 Multicast 4. Select your choice, and then press any key. The Router Configuration Menu redisplays. 5. Repeat steps 1-4 for each port for which want to set the RIP poisoned reverse version. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Adding a static route To add a static route: 1. On the Main Menu, select Configure IP Router. The Router Configuration Menu displays. ***************************************** * Router Configuration Menu * ***************************************** C. Configure Port IP Address U. Unconfigure Port IP Address S. Add/Remove a Static Route R. Enable/Disable RIP V. Configure RIP Version by Port P. Configure RIP Poisoned Reverse by Port N. Configure DNS Client H. Configure DHCP Client L. Configure DHCP Relay T. Configure Telnet Server Port F. Configure IP Filtering D. Display Route Table Lucent Technologies - 152 - CellPipe™ IAD Series User’s Guide 2. Select Add/Remove a Static Route. The Router Modification Menu displays. ***************************************** * Router Modification Menu * ***************************************** A. Add a Static Route R. Remove a Route F. Add/Change the Default Route T. Remove the Default Route D. Display Route Table 3. Select Add a Static Route. 4. Type the destination address that you want to add, and then press ENTER. 5. Type the network mask, and then press ENTER. 6. Type the gateway address, press ENTER, and then type Y. The Router Modification Menu redisplays. 7. Repeat steps 1-6 for each route that you want to add. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Adding a default route To add a default route: 1. On the Main Menu, select Configure IP Router. The Router Configuration Menu displays. ***************************************** * Router Configuration Menu * ***************************************** C. Configure Port IP Address U. Unconfigure Port IP Address S. Add/Remove a Static Route R. Enable/Disable RIP V. Configure RIP Version by Port Lucent Technologies - 153 - CellPipe™ IAD Series User’s Guide P. N. H. L. T. F. D. Configure RIP Poisoned Reverse by Port Configure DNS Client Configure DHCP Client Configure DHCP Relay Configure Telnet Server Port Configure IP Filtering Display Route Table 2. Select Add/Remove a Static Route. The Router Modification Menu displays. ***************************************** * Router Modification Menu * ***************************************** A. Add a Static Route R. Remove a Route F. Add/Change the Default Route T. Remove the Default Route D. Display Route Table 3. Select Add/Change the Default Route. 4. Type the gateway address for the default route, press ENTER, and then type Y. The Router Modification Menu displays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 154 - CellPipe™ IAD Series User’s Guide Disabling bridging When you disable bridging globally, it automatically disables bridging for all ports and disables the spanning tree protocol. Disabling bridging globally To disable bridging globally: 1. On the Main Menu, select Configure Bridge. The Bridge Configuration Menu displays. ***************************************** * Bridge Configuration Menu * ***************************************** G. Enable/Disable Bridging Globally P. Enable/Disable Bridging by Port A. Configure Bridge Aging Timer T. Enable/Disable Spanning Tree Globally O. Enable/Disable Spanning R. Configure Spanning Tree Priority Q. Configure Spanning Tree H. Configure Spanning Tree S. Configure Spanning Tree F. Configure Spanning Tree C. Configure Spanning Tree Tree by Port Bridge Port Priority Hello Time Max Age Forward Delay Path Cost D. Delete Bridge Forwarding Database Entry 2. Select Enable/Disable Bridging Globally, and the type D. The Bridge Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 155 - CellPipe™ IAD Series User’s Guide Disabling bridging by port To disable bridging by port: 1. On the Main Menu, select Configure Bridge. The Bridge Configuration Menu displays. ***************************************** * Bridge Configuration Menu * ***************************************** G. Enable/Disable Bridging Globally P. Enable/Disable Bridging by Port A. Configure Bridge Aging Timer T. Enable/Disable Spanning Tree Globally O. Enable/Disable Spanning R. Configure Spanning Tree Priority Q. Configure Spanning Tree H. Configure Spanning Tree S. Configure Spanning Tree F. Configure Spanning Tree C. Configure Spanning Tree Tree by Port Bridge Port Priority Hello Time Max Age Forward Delay Path Cost D. Delete Bridge Forwarding Database Entry 2. Select Enable/Disable Bridging by Port. The following instructions display on-screen: Available Interfaces : 1. G7070 ADSL ATU-R 1. T1/E1 1. SDSL 2. 10/100BaseT Ethernet 0. (Abort) Selection : Interfaces may not display, depending on the IAD in use. 3. Type the number of the port for which you want to disable bridging, and then type D. Lucent Technologies - 156 - CellPipe™ IAD Series User’s Guide 4. Repeat steps 1-3 for each port on which you want to disable bridging. The Bridge Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Disabling STP To configure the CellPipe IADs as a router, you must disable Spanning Tree Protocol (STP) both globally and by port. The order in which you perform the procedures is irrelevant. Disabling STP globally To disable STP globally: 1. On the Main Menu, select Configure Bridge. The Bridge Configuration Menu displays. ***************************************** * Bridge Configuration Menu * ***************************************** G. Enable/Disable Bridging Globally P. Enable/Disable Bridging by Port A. Configure Bridge Aging Timer T. Enable/Disable Spanning Tree Globally O. Enable/Disable Spanning Tree by Port R. Configure Spanning Tree Bridge Priority Q. Configure Spanning Tree Port Priority H. Configure Spanning Tree Hello Time S. Configure Spanning Tree Max Age F. Configure Spanning Tree Forward Delay C. Configure Spanning Tree Path Cost D. Delete Bridge Forwarding Database Entry Lucent Technologies - 157 - CellPipe™ IAD Series User’s Guide 2. Select Enable/Disable Spanning Tree Globally, and the type D. The Bridge Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Disabling STP by port To disable STP by port: 1. On the Main Menu, select Configure Bridge. The Bridge Configuration Menu displays. ***************************************** * Bridge Configuration Menu * ***************************************** G. Enable/Disable Bridging Globally P. Enable/Disable Bridging by Port A. Configure Bridge Aging Timer T. Enable/Disable Spanning Tree Globally O. Enable/Disable Spanning Tree by Port R. Configure Spanning Tree Bridge Priority Q. Configure Spanning Tree Port Priority H. Configure Spanning Tree Hello Time S. Configure Spanning Tree Max Age F. Configure Spanning Tree Forward Delay C. Configure Spanning Tree Path Cost D. Delete Bridge Forwarding Database Entry Lucent Technologies - 158 - CellPipe™ IAD Series User’s Guide 2. Select Enable/Disable Spanning Tree by Port. The following instructions display on-screen: Available Interfaces : 1. G7070 ADSL ATU-R 1. T1/E1 1. SDSL 2. 10/100BaseT Ethernet 0. (Abort) Selection : Interfaces may not display, depending on the IAD in use. 3. Type the number of the port for which you want to disable STP, and then type D. The Bridge Configuration Menu redisplays. 4. Repeat steps 1-3 for each port on which you want to disable STP. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 159 - CellPipe™ IAD Series User’s Guide %ULGJHFRQILJXUDWLRQ This chapter describes how to configure the CellPipe IADs as a bridge. For more information on the menus, submenus and commands in this chapter, see the Menu interface chapter. A bridge is a device that connects and passes packets between two network segments that use the same communications protocol. Bridges operate at the data link layer (Layer 2) of the OSI reference model. In general, a bridge will filter, forward or flood an incoming frame based on the MAC address of that frame. Although the CellPipe IADs come with bridging enabled by default, you must still: Enable bridging globally Enable bridging by port Set the bridge aging timer Disable the RIP poisoned reverse globally Disable the RIP poisoned reverse by port Enable STP globally Enable STP by port You can configure the CellPipe IADs as both a router and a bridge – it depends on your application. A router can improve overall efficiency for a complex network, but a bridge provides better speed and flexibility for the overall network. Lucent Technologies - 160 - CellPipe™ IAD Series User’s Guide Enabling Bridging For bridging to work, you must enable bridging both globally and by port, and then set the bridge aging timer. The order in which you perform the procedures is irrelevant. Enabling bridging globally To enable bridging globally: 1. On the Main Menu, select Configure Bridge. The Bridge Configuration Menu displays. ***************************************** * Bridge Configuration Menu * ***************************************** G. Enable/Disable Bridging Globally P. Enable/Disable Bridging by Port A. Configure Bridge Aging Timer T. Enable/Disable Spanning Tree Globally O. Enable/Disable Spanning R. Configure Spanning Tree Priority Q. Configure Spanning Tree H. Configure Spanning Tree S. Configure Spanning Tree F. Configure Spanning Tree C. Configure Spanning Tree Tree by Port Bridge Port Priority Hello Time Max Age Forward Delay Path Cost D. Delete Bridge Forwarding Database Entry 2. Select Enable/Disable Bridging Globally, and the type E. The Bridge Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 161 - CellPipe™ IAD Series User’s Guide Enabling bridging by port To enable bridging by port: 1. On the Main Menu, select Configure Bridge. The Bridge Configuration Menu displays. ***************************************** * Bridge Configuration Menu * ***************************************** G. Enable/Disable Bridging Globally P. Enable/Disable Bridging by Port A. Configure Bridge Aging Timer T. Enable/Disable Spanning Tree Globally O. Enable/Disable Spanning R. Configure Spanning Tree Priority Q. Configure Spanning Tree H. Configure Spanning Tree S. Configure Spanning Tree F. Configure Spanning Tree C. Configure Spanning Tree Tree by Port Bridge Port Priority Hello Time Max Age Forward Delay Path Cost D. Delete Bridge Forwarding Database Entry 2. Select Enable/Disable Bridging by Port. The following instructions display on-screen: Available Interfaces : 1. G7070 ADSL ATU-R 1. T1/E1 1. SDSL 2. 10/100BaseT Ethernet 0. (Abort) Selection : Interfaces may not display, depending on the CellPipe IAD in use. Lucent Technologies - 162 - CellPipe™ IAD Series User’s Guide 3. Type the number of the port for which you want to disable bridging, and then type E. The Bridge Configuration Menu redisplays. 4. Repeat steps 1-3 for each port on which you want to disable bridging. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Setting the bridge aging timer The bridge aging timer sets the amount of time that the CellPipe IADs keep a MAC address in the bridging table. When the timer reaches zero, the database deletes the address and creates a new bridge. To set the bridge aging timer: 1. On the Main Menu, select Configure Bridge. The Bridge Configuration Menu displays. ***************************************** * Bridge Configuration Menu * ***************************************** G. Enable/Disable Bridging Globally P. Enable/Disable Bridging by Port A. Configure Bridge Aging Timer T. Enable/Disable Spanning Tree Globally O. Enable/Disable Spanning Tree by Port R. Configure Spanning Tree Bridge Priority Q. Configure Spanning Tree Port Priority H. Configure Spanning Tree Hello Time S. Configure Spanning Tree Max Age F. Configure Spanning Tree Forward Delay C. Configure Spanning Tree Path Cost D. Delete Bridge Forwarding Database Entry Lucent Technologies - 163 - CellPipe™ IAD Series User’s Guide 2. Select Configure Bridge Aging Timer. The following instructions display on-screen: Enter Bridge Aging time in seconds (1..3600): (300) 3. Type the bridge aging time (range = 1-3600 seconds), or press ENTER to accept the default of 300 seconds. 4. Press any key. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Disabling RIP poisoned reverse Conversely, for bridging to work, you must disable RIP both globally and locally (by port). The order in which you perform the procedures is irrelevant. Disabling RIP poisoned reverse globally To disable RIP poisoned reverse globally: 1. On the Main Menu, select Configure IP Router. The Router Configuration Menu displays. ***************************************** * Router Configuration Menu * ***************************************** C. Configure Port IP Address U. Unconfigure Port IP Address S. Add/Remove a Static Route R. Enable/Disable RIP V. Configure RIP Version by Port P. Configure RIP Poisoned Reverse by Port N. Configure DNS Client H. Configure DHCP Client L. Configure DHCP Relay T. Configure Telnet Server Port F. Configure IP Filtering D. Display Route Table Lucent Technologies - 164 - CellPipe™ IAD Series User’s Guide 2. Select Enable/Disable RIP, and then type D. The Router Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Disabling RIP poisoned reverse by port To disable RIP poisoned reverse by port: 1. On the Main Menu, select Configure IP Router. The Router Configuration Menu displays. ***************************************** * Router Configuration Menu * ***************************************** C. Configure Port IP Address U. Unconfigure Port IP Address S. Add/Remove a Static Route R. Enable/Disable RIP V. Configure RIP Version by Port P. N. H. L. T. F. D. Configure RIP Poisoned Reverse by Port Configure DNS Client Configure DHCP Client Configure DHCP Relay Configure Telnet Server Port Configure IP Filtering Display Route Table 2. Select Configure RIP Poisoned Reverse by Port. The following instructions display on-screen: Available Interfaces : 1. G7070 ADSL ATU-R 1. T1/E1 1. SDSL 2. 10/100BaseT Ethernet 0. (Abort) Selection : Interfaces may not display, depending on the CellPipe IAD in use. Lucent Technologies - 165 - CellPipe™ IAD Series User’s Guide 3. Type the number of the port for which you want to disable poisoned reverse. The following instructions display on-screen: RIP Poisoned Reverse for Slot 1, Port 1 is currently DISABLED Enter E to Enable, D to Disable : 4. Type D. The Router Configuration Menu displays. 5. Repeat steps 1-4 for each port for which you want to disable RIP poisoned reverse. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Enabling STP Having many bridges creates the potential for network loops. A loop presents conflicting information about the segment on which a specific address is located and forces the bridge to forward all data. When you enable Spanning Tree Protocol, the CellPipe IADs reconfigure the bridge network to channel data along an optimum route to its destination. Enabling STP globally To enable STP globally: 1. On the Main Menu, select Configure Bridge. The Bridge Configuration Menu displays. ***************************************** * Bridge Configuration Menu * ***************************************** G. Enable/Disable Bridging Globally P. Enable/Disable Bridging by Port A. Configure Bridge Aging Timer T. Enable/Disable Spanning Tree Globally O. Enable/Disable Spanning Tree by Port R. Configure Spanning Tree Bridge Priority Q. Configure Spanning Tree Port Priority Lucent Technologies - 166 - CellPipe™ IAD Series User’s Guide H. S. F. C. Configure Configure Configure Configure Spanning Spanning Spanning Spanning Tree Tree Tree Tree Hello Time Max Age Forward Delay Path Cost D. Delete Bridge Forwarding Database Entry 2. Select Enable/Disable Spanning Tree Globally, and the type E. The Bridge Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Enabling STP by port To enable STP by port: 1. On the Main Menu, select Configure Bridge. The Bridge Configuration Menu displays. ***************************************** * Bridge Configuration Menu * ***************************************** G. Enable/Disable Bridging Globally P. Enable/Disable Bridging by Port A. Configure Bridge Aging Timer T. Enable/Disable Spanning Tree Globally O. Enable/Disable Spanning Tree by Port R. Configure Spanning Tree Bridge Priority Q. Configure Spanning Tree Port Priority H. Configure Spanning Tree Hello Time S. Configure Spanning Tree Max Age F. Configure Spanning Tree Forward Delay C. Configure Spanning Tree Path Cost D. Delete Bridge Forwarding Database Entry Lucent Technologies - 167 - CellPipe™ IAD Series User’s Guide 2. Select Enable/Disable Spanning Tree by Port. The following instructions display on-screen: Available Interfaces : 1. G7070 ADSL ATU-R 1. T1/E1 1. SDSL 2. 10/100BaseT Ethernet 0. (Abort) Selection : Interfaces may not display, depending on the CellPipe IAD in use. 3. Type the number of the port for which you want to enable STP, and then type E. 4. Repeat steps 1-3 for each port on which you want to enable STP. The Bridge Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 168 - CellPipe™ IAD Series User’s Guide '+&3VHUYHUFRQILJXUDWLRQ This chapter walks you through the steps required to configure the Dynamic Host Configuration Protocol (DHCP) server. For more information on the menus, submenus and commands in this chapter, see the Menu interface chapter. DHCP allows for dynamic allocation of network addresses and configurations to newly attached hosts. DHCP reduces the work required to administer a large network. You must complete the following steps to configure the DHCP server: Enable DHCP (factory default = disabled) Configure the DHCP server parameters Configure the DHCP address range pool Enabling DHCP To enable DHCP: 1. On the Main Menu, select Configure DHCP Server. The DHCP Server Configuration Menu displays. ***************************************** * DHCP Server Configuration Menu * ***************************************** E. Enable/Disable DHCP B. Enable/Disable DHCP Debug Messages I. Configure DHCP Server Parameters P. Configure DHCP Address Range Pool C. Configure DHCP Client Entry F. Display DHCP Configuration S. Display DHCP Server Statistics A. Display DHCP Server Assigned Addresses U. Display DHCP Server Unassigned Addresses Lucent Technologies - 169 - CellPipe™ IAD Series User’s Guide D. Display DHCP Entry Details X. Delete A DHCP Client Entry Y. Delete A DHCP Assignment Entry 2. Select Enable/Disable DHCP. The following instructions display on-screen: DHCP Server is currently DISABLED Enter E to Enable, D to Disable : 3. Type E. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring the DHCP server parameters To configure the DHCP server parameters: 1. On the Main Menu, select Configure DHCP Server. The DHCP Server Configuration Menu displays. ***************************************** * DHCP Server Configuration Menu * ***************************************** E. Enable/Disable DHCP B. Enable/Disable DHCP Debug Messages I. Configure DHCP Server Parameters P. Configure DHCP Address Range Pool C. Configure DHCP Client Entry F. Display DHCP Configuration S. Display DHCP Server Statistics A. Display DHCP Server Assigned Addresses U. Display DHCP Server Unassigned Addresses D. Display DHCP Entry Details X. Delete A DHCP Client Entry Y. Delete A DHCP Assignment Entry Lucent Technologies - 170 - CellPipe™ IAD Series User’s Guide 2. Select Configure DHCP Server Parameters. The following instructions display on-screen: Current Gateway address = 0.0.0.0 Enter new Gateway IP address: 3. Type the new gateway IP address, and then press ENTER. If there is no gateway available, type the address of the Ethernet port. The following instructions display on-screen: Current DNS Server address = 0.0.0.0 Enter new DNS Server IP address: 4. Type the new DNS server IP address, and then press ENTER. The following instructions display on-screen: Current Subnet Mask = 0.0.0.0 Enter new Subnet Mask: 5. Type the subnet mask to return to DHCP clients, and then press ENTER. The following instructions display on-screen: Current Domain name = Enter new Domain Name: 6. Type the domain name to return to DHCP clients, and then press ENTER. The following instructions display on-screen: Current Lease time is 0 seconds Enter DHCP Lease Time in seconds 7. Type the new lease time, and then press ENTER. The DHCP Server Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 171 - CellPipe™ IAD Series User’s Guide Configuring the DHCP address range pool You must configure the DHCP address range pool to set the range of IP addresses to return to the DHCP clients. To configure the DHCP address range pool: 1. On the Main Menu, select Configure DHCP Server. The DHCP Server Configuration Menu displays. ***************************************** * DHCP Server Configuration Menu * ***************************************** E. Enable/Disable DHCP B. Enable/Disable DHCP Debug Messages I. Configure DHCP Server Parameters P. C. F. S. A. U. Configure DHCP Address Range Pool Configure DHCP Client Entry Display DHCP Configuration Display DHCP Server Statistics Display DHCP Server Assigned Addresses Display DHCP Server Unassigned Addresses D. Display DHCP Entry Details X. Delete A DHCP Client Entry Y. Delete A DHCP Assignment Entry 2. Select Configure DHCP Address Range Pool. The following instructions display on-screen: Current High IP address of range pool = 0.0.0.0 Enter new High IP address: 3. Type the new high IP address, and then press ENTER. The following instructions display on-screen: Current Low IP address of range pool = 0.0.0.0 Enter new Low IP address: 4. Type the new low IP address, and then press ENTER. The DHCP Server Configuration Menu redisplays. Lucent Technologies - 172 - CellPipe™ IAD Series User’s Guide You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 173 - CellPipe™ IAD Series User’s Guide 1$7FRQILJXUDWLRQ This chapter walks you through the steps required to configure the Network Address Translation (NAT). For more information on the menus, submenus and commands in this chapter, see the Menu interface chapter. The setup of IP networks can be difficult and time consuming, as each requires an IP address, subnet mask, DNS address and a default router. If you enter once piece of information incorrectly, the network connection does not function and there may be no indication of what is wrong. NAT prevents this scenario by: Modifying IP addresses and checksum without affecting traffic. Automatic network configuration - if you configure DHCP. For more information, see the DHCP configuration chapter. Packet level filtering and routing. Traffic logging. A significant advantage of NAT lies in the fact that you can configure it without having to change host or routers – other than those few routers on which NAT is configured. NAT multiplexes traffic from the internal network and presents it to the Internet as if it is from a single source that has only one IP address. You must complete the following steps to configure NAT: Enable NAT translation by port (factory default = disabled) Configure the NAT local server entry Configure the NAT Transmission Control Protocol (TCP) or User Datagram Protocol (UDP) timeouts Configure the NAT port range Lucent Technologies - 174 - CellPipe™ IAD Series User’s Guide Enabling NAT translation To enable the NAT translation by port: 1. On the Main Menu, select Configure NAT. The NAT Configuration Menu displays. ***************************************** * NAT Configuration Menu * ***************************************** B. Enable/Disable NAT Debug Messages P. Enable/Disable NAT Translation by Port T. Configure NAT TCP Timeout U. Configure NAT UDP Timeout R. Configure NAT Port Range N. S. C. D. O. X. Y. Configure NAT Local Server Entry Display NAT Statistics Display NAT Connection Table Display NAT Connection Details Display NAT Local Server Table Delete IP Address from NAT Tables Delete NAT Local Server Entry 2. Select Enable/Disable NAT Translation by Port. The following instructions display on-screen: Available Interfaces : 1. G7070 ADSL ATU-R 1. T1/E1 1. SDSL 2. 10/100BaseT Ethernet 0. (Abort) Selection : Interfaces may not display, depending on the IAD in use. 3. Type the number of the port for which you want to enable NAT, and then type E. The NAT Configuration Menu redisplays. Lucent Technologies - 175 - CellPipe™ IAD Series User’s Guide You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring the NAT local server entry When you configure the NAT local server, it allows access from the Internet via the IP address of the NAT-enabled port. To configure the NAT local server entry: 1. On the Main Menu, select Configure NAT. The NAT Configuration Menu displays. ***************************************** * NAT Configuration Menu * ***************************************** B. Enable/Disable NAT Debug Messages P. Enable/Disable NAT Translation by Port T. Configure NAT TCP Timeout U. R. N. S. C. D. O. X. Y. Configure NAT UDP Timeout Configure NAT Port Range Configure NAT Local Server Entry Display NAT Statistics Display NAT Connection Table Display NAT Connection Details Display NAT Local Server Table Delete IP Address from NAT Tables Delete NAT Local Server Entry 2. Select Configure NAT Local Server Entry. The following instructions display on-screen: Enter NAT Local Server Entry to Configure (1..10): (1) 3. Type the local server entry to configure (range = 1-10), and then press ENTER. The following instructions display on-screen: Current NAT Local Server Translated IP Address = 0.0.0.0 Enter new NAT Local Server Translated IP address: Lucent Technologies - 176 - CellPipe™ IAD Series User’s Guide 4. Type the new translated IP address (range = 1-65535), and then press ENTER. The following instructions display on-screen: Current NAT Local Server Translated IP Address = 0.0.0.0 Enter new NAT Local Server Standard IP address: 5. Type the new standard IP address (range = 1-65535), and then press ENTER. The following instructions display on-screen: Enter NAT Local Server Protocol (1=TCP 2=UDP): 6. Select the local server protocol, and then press any key. The NAT Configuration Menu displays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Configuring the NAT timeouts Under normal circumstances, the timeout default setting is adequate. However, if you interact with multiple-player IP games or video conferencing, you need to configure the timeout. The local server protocol that you select determines which timeout to configure. TDP and UDP are similar, except that TCP tracks TCP clients on a per-connection basis and removes them from the table as soon as the connection closes. Lucent Technologies - 177 - CellPipe™ IAD Series User’s Guide Configuring a NAT TCP timeout To configure a NAT TCP timeout: 1. On the Main Menu, select Configure NAT. The NAT Configuration Menu displays. ***************************************** * NAT Configuration Menu * ***************************************** B. Enable/Disable NAT Debug Messages P. Enable/Disable NAT Translation by Port T. Configure NAT TCP Timeout U. Configure NAT UDP Timeout R. N. S. C. D. O. X. Y. Configure NAT Port Range Configure NAT Local Server Entry Display NAT Statistics Display NAT Connection Table Display NAT Connection Details Display NAT Local Server Table Delete IP Address from NAT Tables Delete NAT Local Server Entry 2. Select Configure NAT TCP Timeout. The following instructions display on-screen: Enter NAT TCP Connection Timeout in seconds (60..3600): (300) 3. Type the TCP timeout value (range = 60-3600 seconds), press ENTER, and then press any key to continue. The NAT Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 178 - CellPipe™ IAD Series User’s Guide Configuring a NAT UDP timeout To configure a NAT UDP timeout: 1. On the Main Menu, select Configure NAT. The NAT Configuration Menu displays. ***************************************** * NAT Configuration Menu * ***************************************** B. Enable/Disable NAT Debug Messages P. Enable/Disable NAT Translation by Port T. Configure NAT TCP Timeout U. Configure NAT UDP Timeout R. N. S. C. D. O. X. Y. Configure NAT Port Range Configure NAT Local Server Entry Display NAT Statistics Display NAT Connection Table Display NAT Connection Details Display NAT Local Server Table Delete IP Address from NAT Tables Delete NAT Local Server Entry 2. Select Configure NAT UDP Timeout. The following instructions display on-screen: Enter NAT UDP Connection Timeout in seconds (60..3600): (120) 3. Type the UDP timeout value (range = 60-3600 seconds), press ENTER, and then press any key to continue. The NAT Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 179 - CellPipe™ IAD Series User’s Guide Configuring the NAT port range Under normal circumstances, the port range default setting is adequate. However, if you interact with multiple-player IP games or video conferencing, you need to configure the port range setting. To multiplex several connections to a single destination, the CellPipe IAD assigns all packets unique port numbers. Each IP packet starts with a header that contain the source and destination addresses, as well as two port numbers. The addresses specify the two routers at each end, while the two port numbers ensure the unique identification of each router pair. When the CellPipe IAD sends TCP or UDP connection from a local port to an Internet port, it changes the sent IP address to the address of the Internet port. Similarly, it changes the TCP or UDP connection port number to a unique value within the NAT port range. The NAT port range must not include any ports that use applications such as HTTP, TFTP and so on. To configure the NAT port range: 1. On the Main Menu, select Configure NAT. The NAT Configuration Menu displays. ***************************************** * NAT Configuration Menu * ***************************************** B. Enable/Disable NAT Debug Messages P. Enable/Disable NAT Translation by Port T. Configure NAT TCP Timeout U. Configure NAT UDP Timeout R. Configure NAT Port Range N. Configure NAT Local Server Entry S. Display NAT Statistics C. Display NAT Connection Table D. Display NAT Connection Details O. Display NAT Local Server Table X. Delete IP Address from NAT Tables Y. Delete NAT Local Server Entry Lucent Technologies - 180 - CellPipe™ IAD Series User’s Guide 2. Select Configure NAT Port Range. The following instructions display on-screen: Enter Low End of NAT Port Range (5000..65534): (50000) 3. Type the low end value (range = 5000-65534), and then press ENTER. The following instructions display on-screen: Enter High End of NAT Port Range (5010..65534): (50000) 4. Type the high end value (range = 5000-65534), and then press ENTER. The NAT Configuration Menu redisplays. You must restart the CellPipe IAD for any changes to take effect. For more information on restarting the CellPipe IADs, see the Getting started chapter. Lucent Technologies - 181 - CellPipe™ IAD Series User’s Guide 9HULILFDWLRQ This chapter describes how to verify that the CellPipe IADs operate properly after installation. It also covers maintenance, and how to display the current configuration. Before you can test the voice capabilities of the CellPipe IADs, you must first provision it at the voice gateway. Power-up test The CellPipe IADs show a brief indication of normal operation when you first turn on the IAD – verify that the POWER indicator on the front panel lights green. Operational test The following procedure assumes that: You configured Directory numbers (DNs) in the Class 5 switch for the associated POTS ports. For more information, see the WAN configuration chapter. You configured PVCs at the DSLAM (defaults = 0, 38 – data and 0, 39 – voice) - assumes ATM only. For more information, see the WAN configuration chapter. You configured a data network. For more information, see the WAN configuration chapter. You have a dedicated communications circuit available between yourself and a counterpart connected to the associated voice gateway via the CellPipe IAD. You connected and configured a WAN link at the associated DSLAM. For more information, see the WAN configuration chapter. You have a PC that has an Ethernet adapter and runs a TCP/IP stack. For more information, see the Getting started chapter. Lucent Technologies - 182 - CellPipe™ IAD Series User’s Guide To test the CellPipe IAD: 1. Verify the WAN link status. 2. Connect a standard voice telephone set to one of the configured line ports on the CellPipe IAD. 3. Pick up the telephone receiver and check for a dial tone. If no dial tone is present, troubleshoot as necessary. 4. Repeat steps 2-3 for each provisioned line. 5. Disconnect the telephone once you are through testing the analog telephone ports. 6. Use a crossover cable to connect the PC to the Ethernet LAN port on the CellPipe IAD. 7. Ping a known good address on the CellPipe IAD, and then wait for acknowledgement. If a timeout occurs, troubleshoot the LAN path to the CellPipe IAD as necessary. 8. Ping a known good address on the network, and then wait for acknowledgement. If a timeout occurs, troubleshoot the LAN path to the CellPipe IAD as necessary. 9. Disconnect the PC from the Ethernet LAN port. 10. Use a straight-through cable to connect the Ethernet LAN port to your local LAN patch panel or hub. 11. Connect the CellPipe IAD telephone ports to the local distribution frame or patch panel. The CellPipe IAD is ready for service. Maintenance The CellPipe IAD Menu interface contains built-in utilities for maintenance and development. Call the Lucent Technical Support Center if you have any questions: - 1-866-237-4448 inside the US - 1-630-218-7688 outside the US Lucent Technologies - 183 - CellPipe™ IAD Series User’s Guide Displaying the current configuration To display the current configuration and data transmission status: 1. On the Main Menu, select Reports Menu. The Reports Menu displays. ***************************************** * Reports Menu * ***************************************** C. Display Current Configuration N. Display Network Statistics I. Display Interface Statistics M. Display Media Statistics R. Display Route Table A. Display ARP Table B. Display Bridge Forwarding Database S. Display Bridge Status P. Display PPP Authorization Entries U. Display System Uptime O. Display Memory Statistic 2. Select Display Current Configuration. 3. Follow the on-screen instructions to view the information on the individual slots and ports. Lucent Technologies - 184 - CellPipe™ IAD Series User’s Guide $ 0HQXKLHUDUFK\ 1. Reports Menu C. Display Current Configuration N. Display Network Statistics C. Display ICMP Statistics I. Display IP Statistics T. Display TCP Statistics U. Display UDP Statistics Z. Clear a Network Statistic C. Clear ICMP Statistics I. Clear IP Statistics T. Clear TCP Statistics U. Clear UDP Statistics I. Display Interface Statistics A. Display ARP Statistics I. Display Interface Statistics B. Display Bridge Statistics D. Display DLCI Statistics Z. Clear a Statistic A. Clear ARP Statistics I. Clear Interface Statistics B. Clear Bridge Statistics D. Clear Frame Relay DLCI Statistics A. Clear ATM PVC Statistics A. Display ATM PVC Statistics Z. Clear ATM PVC Statistics Lucent Technologies - 185 - CellPipe™ IAD Series User’s Guide M. Display Media Statistics F. Display Frame Relay Statistics S. Display Serial Statistics Z. Clear a Statistic F. Clear Frame Relay DLCI Statistics S. Clear Serial Statistics 1. Display ATM Statistics Z. Clear ATM Statistics 2. Display ATM Statistics F. Display Frame Relay Statistics S. Display Serial Statistics Z. Clear a Statistic 1. Clear G2237 ADSL Statistics 2. Clear ATM Statistics F. Clear Frame Relay DLCI Statistics S. Clear Serial Statistics 1. Display G7070 ADSL Statistics 2. Display ATM Statistics F. Display Frame Relay Statistics S. Display Serial Statistics Z. Clear a Statistic 1. Clear G7070 ADSL Statistics 2. Clear ATM Statistics F. Clear Frame Relay DLCI Statistics S. Clear Serial Statistics 1. Display ENET Statistics Z. Clear ENET Statistics 1. Display POTS Statistics Z. Clear POTS Statistics R. Display Route Table A. Display ARP Table B. Display Bridge Forwarding Database S. Display Bridge Status P. Display PPP Authorization Entries Lucent Technologies - 186 - CellPipe™ IAD Series User’s Guide U. Display System Uptime O. Display Memory Statistic M. Display System Memory Statistic T. Display Kernel Tasks Memory Statistic 2. Configure IP Router C. Configure Port IP Address U. Unconfigure Port IP Address S. Add/Remove a Static Route A. Add a Static Route R. Remove a Route F. Add/Change the Default Route T. Remove the Default Route D. Display Route Table R. Enable/Disable RIP V. Configure RIP Version by Port P. Configure RIP Poisoned Reverse by Port N. Configure DNS Client A. Set DNS Server IP Address T. Set DNS Server Timeout S. Display DNS Cache and Statistics H. Configure DHCP Client L. Configure DHCP Relay E. Enable/Disable DHCP Relay C. Configure DHCP Relay S. Display DHCP Relay Statistics T. Configure Telnet Server Port F. Configure IP Filtering P. Choose port for IP filtering F. Globally enable/disable input or output filters T. Toggle input or output type filters to view/edit Lucent Technologies - 187 - CellPipe™ IAD Series User’s Guide D. Display all filters of the chosen type I. Insert a new or buffered filter of the chosen type A. Append a new or buffered filter to the end of the list E. Edit a filter of the chosen type C. Copy filter operations menu C. Copy a filter of the chosen type to the buffer D. Display the filter in the copy buffer E. Edit the filter in the copy buffer X. Delete the filter from the copy buffer X. Delete one filter of the chosen type Z. Delete all filters of the chosen type S. Show IP filtering statistics Y. Clear IP filtering statistics D. Display Route Table 3. Configure Bridge G. Enable/Disable Bridging Globally P. Enable/Disable Bridging by Port A. Configure Bridge Aging Timer T. Enable/Disable Spanning Tree Globally O. Enable/Disable Spanning Tree by Port R. Configure Spanning Tree Bridge Priority Q. Configure Spanning Tree Port Priority H. Configure Spanning Tree Hello Time S. Configure Spanning Tree Max Age F. Configure Spanning Tree Forward Delay C. Configure Spanning Tree Path Cost D. Delete Bridge Forwarding Database Entry Lucent Technologies - 188 - CellPipe™ IAD Series User’s Guide 5. Configure WAN 0. Quick Configuration (CellPipe IAD 4S/8S0) 1. Lucent Stinger (Conexant Autobaud, Payload Scrambling) 2. Nokia (Auto Cycle) 3. Copper Mountain (Auto Sense) 4. Paradyne (Framed 784 Kbps, Payload Scrambling) 5. AccessLan CPE 6. Nortel IMAS 7. ATM (Unframed, 1152kpbs fixed) 8. Frame Relay (784 Kbps fixed) 1. Configure Datalink Protocol 1. Totally Transparent 2. Raw HDLC 3. Cisco compatible HDLC 4. IP-Plus compatible HDLC 5. PPP (over Raw HDLC) 6. ATM 7. Frame Relay 2. Configure Physical Interface ADSL Mode 1. G7070ConfigStandard 1. T1.413 2. G.LITE 3. G. DMT 4. Alcatel 1.4 5. Multi-Mode 6. ADI 7. ALCATEL d. Enable/Disable ADSL Debug Messages SDSL Mode 1. Toggle SDSL Mode (CO or CPE) 2. Set SDSL Speed To Auto Cycle (Nokia) Lucent Technologies - 189 - CellPipe™ IAD Series User’s Guide 1. 1536 Kbps 2. 1152 Kbps 3. 768 Kbps 4. 384 Kbps 5. 192 Kbps 3. Set SDSL Speed to Auto Sense (Copper Mountain) 4. Enable/Disable Conexant Autobaud Mode 5. Set SDSL Sync Delay (Lucent) 6. Set SDSL to AccessLan CPE Mode 7. Set SDSL for IMAS DSLAM (Nortel) 8. Set SDSL Speed Manually 9. SDSL Interface Mode (Bit Order) D. SDSL Debug Menu 1. Restart SDSL Activation Sequence 2. Enable/Disable SDSL Autobaud Debug Messages 3. Enable/Disable SDSL Debug Messages 4. Enable/Disable Sync Msgs 5. Preactivation Debug Mode T1 Mode 1. Select Frame Mode (D4 Or ESF) 1. ESF Frame Mode 2. D4 Frame Mode 2. Select Line Build Out 1. 0 To 133 Feet (0 dB) 2. 133 To 266 Feet 3. 266 To 399 Feet 4. 399 To 533 Feet 5. 533 To 655 Feet 6. -7.5 dB 7. -15 dB 8. -22.5 dB 3. Enable/Disable B8ZS 6. Configure Transmit Channels 1. Enable All Channels 2. Disable All Channels 3. Select Individual Channels Lucent Technologies - 190 - CellPipe™ IAD Series User’s Guide 4. Select Channel Range 7. Configure Receive Channels 1. Enable All Channels 2. Disable All Channels 3. Select Individual Channels 4. Select Channel Range 8. Configure Tx Clock Source 1. External (Slave Mode) 2. Internal (Master Mode) 9. Change To E1 Mode E1 Mode (currently not supported) 1. Select Frame/CRC4 Mode 1. FAS 2. FAS (CRC4 Enabled) 3. Multi-Frame CAS 4. Multi-Frame CAS (CRC4 Enabled) 3. Configure S-Bits 2. Toggle Sa4 Bit 3. Toggle Sa5 Bit 4. Toggle Sa6 Bit 5. Toggle Sa7 Bit 6. Toggle Sa8 Bit 4. Configure Transmit Channels 1. Enable All Channels 2. Disable All Channels 3. Select Individual Channels 4. Select Channel Range 5. Configure Receive Channels 1. Enable All Channels 2. Disable All Channels 3. Select Individual Channels 4. Select Channel Range 6. Configure Clock Source 1. External (Slave Mode) 2. Internal (Master Mode) 7. Change To T1 Mode Lucent Technologies - 191 - CellPipe™ IAD Series User’s Guide 3. Configure DLCIs (Datalink Protocol = Frame Relay) 1. Add New DLCI 1. RAW (No Encapsulation) 1. Configure Transmit CIR 2. Configure Receive CIR 3. Configure FRF.12 Fragmentation 1. Enable/Disable End-To-End FRF.12 2. Set Fragment Size 2. Proprietary Voice DLCI 1. Configure Transmit CIR 2. Configure Receive CIR 3. Configure FRF.12 Fragmentation 1. Enable/Disable End-To-End FRF.12 2. Set Fragment Size 3. RFC 1490 1. Configure Transmit CIR 2. Configure Receive CIR 3. Configure FRF.12 Fragmentation 1. Enable/Disable End-To-End FRF.12 2. Set Fragment Size 4. ATM RFC 1483 (Tunneling) 1. Configure Transmit CIR 2. Configure Receive CIR 3. Configure FRF.12 Fragmentation 1. Enable/Disable End-To-End FRF.12 2. Set Fragment Size 2. Modify Existing DLCI 1. RAW (No Encapsulation) 1. Configure Transmit CIR 2. Configure Receive CIR 3. Configure FRF.12 Fragmentation 1. Enable/Disable End-To-End FRF.12 2. Set Fragment Size 2. Proprietary Voice DLCI 1. Configure Transmit CIR 2. Configure Receive CIR Lucent Technologies - 192 - CellPipe™ IAD Series User’s Guide 3. Configure FRF.12 Fragmentation 1. Enable/Disable End-To-End FRF.12 2. Set Fragment Size 3. RFC 1490 1. Configure Transmit CIR 2. Configure Receive CIR 3. Configure FRF.12 Fragmentation 1. Enable/Disable End-To-End FRF.12 2. Set Fragment Size 4. ATM RFC 1483 (Tunneling) 1. Configure Transmit CIR 2. Configure Receive CIR 3. Configure FRF.12 Fragmentation 1. Enable/Disable End-To-End FRF.12 2. Set Fragment Size 3. Delete DLCI 4. Show Current DLCIs 3. Configure PVCs (Datalink Protocol = ATM) 1. Add New PVC 1. AAL55 (None) 1. CBR 2. UBR 2. AAL0 (None) 1. CBR 2. UBR 3. Proprietary Voice 4. RFC 1483 (using VC Muxing) 1. CBR 2. UBR 5. RFC 1483 (with LLC Encapsulation) 1. CBR 2. UBR Lucent Technologies - 193 - CellPipe™ IAD Series User’s Guide 6. RFC 2364 (PPPoATM With LLC Encapsulation) 0. None 1. PAP Client 1. CBR 2. UBR 2. PAP Server 1. CBR 2. UBR 3. CHAP Client 1. CBR 2. UBR 4. CHAP Server 1. CBR 2. UBR 7. RFC 2364 (PPPoATM Using VC Muxing) 0. None 1. PAP Client 1. CBR 2. UBR 2. PAP Server 1. CBR 2. UBR 3. CHAP Client 1. CBR 2. UBR 4. CHAP Server 1. CBR 2. UBR 8. AAL1/CES 9. AAL2/LES 1. ITU 1. ITU #1 - 40 octets, G.711-64 2. ATM Forum Lucent Technologies - 194 - CellPipe™ IAD Series User’s Guide 2. Modify Existing PVC 1. AAL55 (None) 1. CBR 2. UBR 2. AAL0 (None) 1. CBR 2. UBR 3. Proprietary Voice 4. RFC 1483 (using VC Muxing) 1. CBR 2. UBR 5. RFC 1483 (with LLC Encapsulation) 1. CBR 2. UBR 6. RFC 2364 (PPPoATM With LLC Encapsulation) 0. None 1. PAP Client 1. CBR 2. UBR 2. PAP Server 1. CBR 2. UBR 3. CHAP Client 1. CBR 2. UBR 4. CHAP Server 1. CBR 2. UBR 7. RFC 2364 (PPPoATM Using VC Muxing) 0. None 1. PAP Client 1. CBR 2. UBR 2. PAP Server 1. CBR 2. UBR Lucent Technologies - 195 - CellPipe™ IAD Series User’s Guide 3. CHAP Client 1. CBR 2. UBR 4. CHAP Server 1. CBR 2. UBR 8. AAL1/CES 9. AAL2/LES 1. ITU 1. ITU #1 - 40 octets, G.711-64 2. ATM Forum 3. Delete PVC 4. Show Current PVCs 4. Configure FR Options (Datalink Protocol = Frame Relay) 1. Configure Fragmentation 1. Configure FRF.12 Fragmentation 1. Enable/Disable FRF.12 2. Enable Automatic Fragment Sizing 3. Set Manual Fragment Size 2. Configure Copper Mountain Fragmentation 1. Enable/Disable CuMtn Fragmentation 2. Set Real-Time DLCI 2. Configure Maintenance Protocol 0. None 1. CCITT Q.933 Annex A Network 2. CCITT Q.933 Annex A User 3. CCITT Q.933 Annex A Both 4. ANSI T1.617 Annex D Network 5. ANSI T1.617 Annex D User 6. ANSI T1.617 Annex D Both 7. LMI Network (FRF.1.1) 8. LMI User (FRF.1.1) 9. LMI Both (FRF.1.1) Lucent Technologies - 196 - CellPipe™ IAD Series User’s Guide 3. Configure Congestion Parameters 1. Configure Transmit Congestion Parameters 2. Configure Receive Congestion Parameters 4. Enable/Disable Copper Mountain CMCP 4. Configure ATM Options (Datalink Protocol = ATM) 1. Configure Payload Scrambling 2. Configure F4 OAM VPI 3. Configure F4 OAM Type 4. Display F4 OAM Configuration 5. Send OAM Loopback 6. Configure Empty Cells 6. Configure LAN F. Set/Clear Full Duplex 7. Configure SNMP E. Enable/Disable SNMP P. Configure System Contact N. Configure System Name L. Configure System Location C. Configure SNMP Community T. Configure SNMP Trap Host IP Address 8. Configure Login 1. Change User ID 2. Change User Password 3. Change NetMan Password 4. Change Supervisor Password Lucent Technologies - 197 - CellPipe™ IAD Series User’s Guide 5. Change Primary RADIUS Server Address 6. Change Primary RADIUS Encryption Secret 7. Change Secondary RADIUS Server Address 8. Change Secondary RADIUS Encryption Secret 9. Display RADIUS Configuration 9. System Utilities P. Ping Utility T. Trace Route Z. Configure Console Baud Rate 0. Unset (use Default) 1. 9600 2. 19200 3. 38400 4. 57600 5. 115200 V. Configure Console Timeout R. Hard Reset or Reload ACOS from FLASH D. Set System Defaults W. Save System Settings as Defaults A. Clear ’Last Reset Reason’ F. File System Menu D. Directory of all files C. Copy file R. Rename File X. Remove File by name F. Format File System drive S. Space left in File System Lucent Technologies - 198 - CellPipe™ IAD Series User’s Guide G. Debug Menu M. Set Ethernet MAC E. Enable/Disable PPP debug mode S. Enable/Disable STP debug mode I. Enable/Disable DHCP Client debug mode Q. Display Error Dump X. File Transfer Menu B. Load Boot ROM 1. Receive via TFTP 2. Receive via XMODEM O. Update ACOS [acos.bin] 1. Receive via TFTP 2. Receive via XMODEM X. Update Entire System A. File Transfer Utilities 1. Receive via TFTP 2. Send or Receive via XMODEM D. Configure DHCP Server E. Enable/Disable DHCP B. Enable/Disable DHCP Debug Messages I. Configure DHCP Server Parameters P. Configure DHCP Address Range Pool C. Configure DHCP Client Entry F. Display DHCP Configuration S. Display DHCP Server Statistics A. Display DHCP Server Assigned Addresses U. Display DHCP Server Unassigned Addresses D. Display DHCP Entry Details Lucent Technologies - 199 - CellPipe™ IAD Series User’s Guide X. Delete A DHCP Client Entry Y. Delete A DHCP Assignment Entry N. Configure NAT B. Enable/Disable NAT Debug Messages P. Enable/Disable NAT Translation by Port T. Configure NAT TCP Timeout U. Configure NAT UDP Timeout R. Configure NAT Port Range N. Configure NAT Local Server Entry S. Display NAT Statistics C. Display NAT Connection Table D. Display NAT Connection Details O. Display NAT Local Server Table X. Delete IP Address from NAT Tables Y. Delete NAT Local Server Entry T. Derived Timing 1. Enable/Disable Derived Timing 2. Enable/Disable Derived Timing Debug Messages 1. Enable/Disable **ALL** Derived Timing Debug Messages 2. Enable/Disable **PSTN ONLY** Derived Timing Debug Messages 3. Enable/Disable **Local Clock ONLY** Derived Timing Debug Messages Lucent Technologies - 200 - CellPipe™ IAD Series User’s Guide Z. Diagnostics Menu P. POTS Diagnostics D. Dialup Test H. Hotline Test S. Power Supply Test P. Phone Detect Test R. Ring Test O. On/Off Hook Test R. Reset System P. VoicePath Configure V. Set Voice Gateway 0. No Voice Gateway 1. MGCP 0.1/NCS 1.0 2. CopperCom 3. JetStream 4. Tollbridge 5. TdSoft 6. AAL2LES J. Set Jitter Delay D. Display Jitter Delay S. Set Start Mode (Loop Start/Ground Start) 1. Set All Ports to Loop Start 2. Set All Ports to Ground Start 3. Display Start Mode 4. Configure Individual Port Lucent Technologies - 201 - CellPipe™ IAD Series User’s Guide T. Set SLIC Control Mode A. AUTO Control Mode M. MANUAL Control Mode U. Set Compander Mode (U-Law, A-Law) U. u-Law Mode A. A-Law Mode O. Set On Hook Transmission Mode Of Ground Start Lines E. ENABLE Ground Start On Hook Transmission D. DISABLE Ground Start On Hook Transmission M. Set Debug Mode E. ENABLE Debug D. DISABLE Debug E. Configure Echo Cancellation Default Settings 1. Set Echo Cancellation default setting for all ports 2. Display current Echo Cancellation default settings 3. Configure Echo Cancellation default setting per port G. Set Loop Gain 1. Set Loop Gain for all ports 2. Display current Loop Gain settings 3. Configure Loop Gain setting per port C. Set Country Mode E. Europe U. USA E. Toggle CMCP Debugging Lucent Technologies - 202 - CellPipe™ IAD Series User’s Guide MGCP/NCS Embedded Client C. Configure MGCP/NCS parameters S. Display MGCP/NCS statistics D. Debug MGCP/NCS 1. Disable all msgs 2. Enable informational msgs 3. Enable Verbose msgs R. Remove a connection A. Port Administration 1. Set Admin State for all ports 2. Display current Admin State 3. Configure Admin State per port 4. Restart Endpoint P. Configure Default Packet Size E. CopperCom Call Control S. Statistics D. Display Statistics C. Clear Statistics C. Configure D. Display Configuration C. Compression Format D. Debug Control L. Display Line Status D. Display Debug State/Flags C. Control Debug (Enable/Disable) S. Set Debug Flags Lucent Technologies - 203 - CellPipe™ IAD Series User’s Guide E. Call Control Settings A. Stats Display R. Ring Test C. Configure Ring Test D. Display Parameters S. Start Ring Test T. Stop Ring Test S. Display IAD State T. Trace S. Set Trace data D. Display Trace data V. Pick sound heard if insufficient WAN B/W to complete call 0. Play Silence 1. Play Fast Beeping U. Configure Tollbridge Voice Client 0. Set client IP address 1. Set voice gateway IP address 2. Print current configuration 3. Debugging Options 0. Enable/Disable all messages 1. Enable/Disable status/keep-alive messages 2. Enable/Disable provisioning messages 3. Enable/Disable state-transition messages Lucent Technologies - 204 - CellPipe™ IAD Series User’s Guide A. Application Menu D. Display information Menu 1. Display POTS database 2. Display ATM database 3. Display CAS signaling 4. Display user port database 5. Display port statistics 6. Display WAN speed 7. Display IAD version S. Set information Menu 1. Set CAS signaling 2. Set CAS signaling to default 3. Set user port database 4. Save user port information 5. Set loopback flag 6. Set print debug information flag 7. Set start Tx counter 8. Set TFTP Server address 9. Set DSP codec type A. Set stop ringer time period A. AAL Type Menu 1. Set AAL2 print debug information flag 2. Display number of sequence errors F. AAL2/LES Call Control C. Configuration C. CAS Signaling S. Toggle CAS Signaling: GR-303 ABCD (US) or MEL TS16 (UK) R. Turn on/off CAS refreshing O. Audio Options Lucent Technologies - 205 - CellPipe™ IAD Series User’s Guide M. Select RX audio cell synchronization mode 1. NONE 2. STANDARD 3. OPTIMIZED D. Set RX audio cell synchronization delay N. Toggle RX audio dejittering seq. no. usage (in STANDARD mode) S. Toggle TX audio cell seq. no. synchronization with Basic Clock P. Set Max. CPS Payload U. Toggle User State Control D. Debug Control L. Display Line Status D. Display Debug State/Flags C. Control Debug (Enable/Disable) S. Set Debug Flags S. Statistics A. Display ALL Statistics B. Display Basic (Audio/CAS/Alarm) Statistics E. Display Basic and Extra Statistics C. Clear Statistics Lucent Technologies - 206 - CellPipe™ IAD Series User’s Guide % &HOO3LSH,$'VSHFLILFDWLRQV Network Interfaces 10/100BaseT Ethernet Shielded RJ-45 ADSL SDSL 2-Wire SDSL (Shielded RJ-11 Connector) Symmetrical data rates from 144 Kbps to 2.3 Mbps in increments of 8 Kbps Transmission range up to 25,000 feet T1/E1 1.544/2.048 Mbps Shielded RJ-48 Connector POTS 4 or 8-Port Bridging and Routing Dynamic and static IP Routing and Bridging IEEE 802.1d Bridging Spanning Tree Protocol RIP1 and RIP2 Information Routing Protocol Internet Control Message Protocol (ICMP) for IP packet processing Network Address Translation (NAT) that allows you to share IP addresses DHCP for management of LAN addresses Lucent Technologies - 207 - CellPipe™ IAD Series User’s Guide WAN Protocols ATM Eight Permanent Virtual Circuits (PVCs) Multiprotocol encapsulation over ATM (RFC 1483) PPP over ATM (RFC 2364) Frame Relay Eight Data-Link Connection Identifiers (DLCI) Multiprotocol encapsulation over Frame Relay (RFC 1490) High-Level Data Link Control (HDLC) Cisco-compatible HDLC Point-to-Point (PPP) Management and Configuration ASCII-based submenu interface for system configuration and monitoring Telnet for remote access to submenu-based Interface SNMP for monitoring, controlling and managing configurations, statistics, performance and security Trivial File Transfer Protocol (TFTP) for software upgrade Environmental External Power Supply 80-250 VAC 10 Watts maximum power consumption (4 ports) 14 Watts maximum power consumption (8 ports) 0 to 50 °C Operating Range 10 to 90% Non-condensing humidity LED Display – Power, SDSL or T1/E1 connectivity and activity, and LAN connectivity and activity Lucent Technologies - 208 - CellPipe™ IAD Series User’s Guide Physical Dimensions (L X W x H) = 11.8" X 8.3" X 1.8". Physical Dimensions (L X W x H) = 9.9" X 6.1" X 1.8" (6500 only). Lucent Technologies - 209 - CellPipe™ IAD Series User’s Guide & &RQQHFWRUSLQRXWV Console Pin 1 2 3 Signal Ground Tx Data Rx Data Pin 1 2 3 4 5 6 7 8 Signal Tx+ TxRx+ NC NC RxNC NC 10BaseT Connector Lucent Technologies - 210 - CellPipe™ IAD Series User’s Guide 100BaseT Connector Pin 1 2 3 4 5 6 7 8 Signal Tx+ TxRx+ NC NC RxNC NC Pin 1 2 3 4 Signal N/C Tip Ring N/C Pin 1 2 3 4 5 6 7 8 Signal Rx Ring Rx Tip NC Tx Tip Tx Ring NC NC NC ADSL/SDSL Connector T1/E1 Connector Lucent Technologies - 211 - CellPipe™ IAD Series User’s Guide ' ,3)LOWHULQJ The following assumes that you have a working knowledge of IP protocols. IP filtering allows you to specify a combination of the following parameters to have the CellPipe IADs selectively eliminate IP traffic: Filtering executes on the WAN port that you select. There are two different sets of filters and each filter maintains its own statistics: Input - Input packets are filtered after the network address translation. Output - Output packets are filtered before the network address translation. The maximum total number of filters is 128. Packets pass through the appropriate set of filters in the order in which the filters display in the list shown on the user interface (Configure IP Router > Configure IP Filtering > Display all filters of the chosen type). Each packet moves down the list of filters until it reaches the end or the attributes of an active filter match the packet. When a match occurs, the packet is then processed according to the action field (Pass or Discard) of the first filter that matched the packet: Pass - packet passed to the next level. Discard - packet discarded. When output packets are dropped, RTCS_OK is returned from IP_route. When you create a new filter, all fields are set to an inactive state. An inactive filter passes all IP packets - you must modify at least one field to narrow the range of packets to pass or change the action to discard all packets. To create a set of filters to pass only certain types of packets, you need to create a default filter that discards all packets and then insert narrower filters before the default filter. For example, you need to add a filter to cover each range of packets. Lucent Technologies - 212 - CellPipe™ IAD Series User’s Guide If you want to select only the packet ranges to discard, then there is no default filter needed, because the default action is to pass all packets. You only have to add filters that set the range to discard and set the actions of those filters to discard. The order of the filters matters if you are mixing filters with different actions or if you want the overlapping filters to display accurate statistics. Lucent Technologies - 213 - CellPipe™ IAD Series User’s Guide ( 6DIHJXDUGV Please read and understand the following instructions before using the system: The Safety status of the SLIC ports on this product are defined as TNV -2. Therefore, cables attached to them should not be subject to overvoltage. To ensure this they should not leave the building in which the Unit is installed. Close supervision is necessary when the system is used by or near children. Do not leave unattended while in use. Only use electrical extension cords with a current rating equal to that of the system. Always disconnect the system from power before cleaning and servicing and when not in use. Do not spray liquids directly onto the system when cleaning. Always apply the liquid first to a static free cloth. Do not immerse the system in any liquid or place any liquids on it. Do not disassemble this system (except as instructed in the manufacturer’s instructions). To reduce the risk of shock and to maintain the warranty on the system, a qualified technician must perform service or repair work. Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightening. Keep ventilation openings free of any obstructions. SAVE THESE INSTRUCTIONS. Lucent Technologies - 214 - CellPipe™ IAD Series User’s Guide Regulatory Notices FCC Notice The CellPipe IAD 4S/8S/8T have been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a Commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The CellPipe IAD 4A has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by Lucent could void the user’s authority to operate this equipment. The CellPipe 8T complies with Part 68 of the FCC Rules. On the bottom of the base of this equipment is a label that contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) for the equipment. You must, upon request, provide this information to your telephone company. Lucent Technologies - 215 - CellPipe™ IAD Series User’s Guide REN is not required for some types of analog or digital facilities. Before connecting your IAD, you must inform the telephone company of the following information: Port ID: SOC/REN USOC FIC: CellPipe IAD 8T SOC = 6.0N RJ48C 04DU9.BN, 04DU9.DN, 04DU9.1KN, 04DU9.1SN CellPipe IAD 4A REN = 0.0B RJ11C - An FCC compliant telephone cord and modular plug is provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack that is Part 68 compliant. See installation instructions for details. The REN is useful to determine the quantity of devices you may connect to your telephone line and still have all those devices ring when your telephone number is called. In most, but not all areas, the sum of the RENs of all devices connected to one line should not exceed five (5). To be certain of the number of devices you may connect to your line, as determined by the REN, you should contact your local telephone company to determine the maximum REN for your calling area. REN is associated with loop-start and ground-start ports. Do not use for E&M or digital ports. If your telephone equipment causes harm to the telephone network, the Telephone Company may discontinue your service temporarily. If possible, they will notify you in advance. However, if advance notice is not practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with the FCC. Your telephone company may make changes in its facilities, equipment, operations, or procedures that could effect the proper functioning of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service. If you experience trouble with any CellPipe IADs, please contact Lucent for information on obtaining service or repairs. For repair or warranty information, contact: Lucent OnLine Customer Support at http://www.lucent.com/support and click Contact Us for a list of telephone numbers inside and outside the United States. Lucent Technologies - 216 - CellPipe™ IAD Series User’s Guide No user serviceable parts are contained in this equipment. This equipment may not be used for coin service provided by the Telephone Company. Connection to party lines is subject to state tariffs. Contact the state Public Utilities Commission or Corporation for information. Do not attempt to repair this equipment yourself. Industry Canada Notice NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, the user needs to ensure that it is permissible to connect to the facilities of the local telecommunications company. The user must also use an acceptable method of connection to install the equipment. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment need to be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.’’ ’’NOTICE: The Ringer Equivalence Number (REN) assigned to each relevant terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.’’ Lucent Technologies - 217 - CellPipe™ IAD Series User’s Guide Underwriters’ Laboratories’ Statement The system is intended to be powered only by the power supply unit provided. Lucent Technologies - 218 - CellPipe™ IAD Series User’s Guide *ORVVDU\ 10/100BaseT 10-Mbps baseband Ethernet specification that uses two pairs of twisted-pair cabling: one pair for transmitting data and the other for receiving data. 10/100BaseT has a distance limit of approximately 100 meters per segment. 100BaseT 100-Mbps baseband Fast Ethernet specification that uses UTP wiring. Like 10/100BaseT, 100BaseT sends link pulses over the network segment when no traffic is present. These link pulses contain more information than those used in 10/100BaseT. ADSL Asymmetric Digital Subscriber Line. ARP Address Resolution Protocol. Enables routers to obtain the Ethernet address for a known IP address. See also Inverse ARP. ATM Asynchronous Transfer Mode. BOOTP Bootstrap Protocol. Used during network booting by a network node to determine the IP address of its Ethernet interfaces. DLCI Data-Link Connection Identifier. Value that specifies a PVC or SVC in a Frame Relay network. In the basic Frame Relay specification, DLCIs are locally significant (connected devices might use different values to specify the same connection). In the LMI extended specification, DLCIs are globally significant (DLCIs specify individual end devices). E1 Network connection with a capacity of 2.048, divided into 32 separate channels (or DS0s). EEPROM Electrically Erasable Programmable read only Memory. Nonvolatile memory chips that can be erased using electrical signals and reprogrammed. Ethernet Physical connection commonly used for LANs. Runs over a variety of cable types and provides bandwidth of 10 Mbps. Invented by Xerox Corporation and developed jointly by Xerox, Intel, and Digital Equipment Corporation. Fast Ethernet Any of a number of 100 Mbps Ethernet specifications. Frame Relay a network interface providing high-speed packet transmission with minimum delay. Uses variablelength packets called frames. Contrast with packet. Lucent Technologies - 219 - CellPipe™ IAD Series User’s Guide Full Duplex ICMP Inverse ARP IP IP address IP SNAP LAN LMI MAC Lucent Technologies Capable of handling simultaneous data transmission between a sending station and a receiving station. Internet Control Message Protocol. Internet protocol that reports errors and provides other information relevant to IP packet processing, such as routing information. Inverse Address Resolution Protocol. Enables routers to obtain the IP address of a known Ethernet address of a device associated with a virtual circuit. Method of building dynamic routes in a network. Internet Protocol. Part of the TCP/IP protocol. IP networks are connectionless, packet switching networks. 32-bit address assigned to hosts using TCP/IP. An IP address contains four octets separated by periods, also known as a dotted quad address. Each address consists of a network number, an optional sub-network number, and a host number. The network and sub-network numbers together are used for routing, while the host number is used to address an individual host within the network or subnetwork. Sub-network Access Protocol. Internet protocol that operates between a network entity in the subnetwork and a network entity in the end system. SNAP specifies a standard method of encapsulating IP datagrams and ARP messages on IEEE networks. The SNAP entity in the end system makes use of the services of the sub-network and performs three essential functions: data transfer, connection management, and QOS selection. Local Area Network. Privately owned networkconnecting devices over a limited geographic area. May use TCP/IP or one of several other protocols. Local Management Interface: enhancements to the basic Frame Relay specification. Called LMT in ANSI terminology. - a keep-alive mechanism that verifies that data is flowing. - a multi-cast mechanism, which provides the network server with its local DLCI and the multicast DLCI. - global addressing, which gives DLCIs global rather than local significance in Frame Relay networks. - a mechanism that provides an on-going status report on the DLCIs known to the switch. Media Access Control. Lower of the two sub-layers of the data link layer defined by the IEEE. - 220 - CellPipe™ IAD Series User’s Guide MAC address Standardized data link layer address that is required for every port or device that connects to a LAN. Other devices in the network use these addresses to locate specific ports in the network and to create and update routing tables and data structures. MAC addresses are six bytes long and are IEEEcontrolled. Also known as a hardware address, a MAC-layer address, or a physical address. MPEG Moving Pictures Expert Group. OSI Reference Model Network architectural model developed by ISO and ITU-T. The model consists of the following seven layers, each of which specifies particular network functions. The lowest layer is closest to the media technology, and the highest layer is closest to the user. Hardware and software implement the lower two layers, while only software implements the upper five layers. Packet Lucent Technologies Physical layer – the actual wires and connections in the network. Data link layer – responsible for physical addressing, network topology, error notification, and ordered delivery. Network layer – responsible for connectivity, path selection, and routing. Transport layer – responsible for network communication, virtual circuit management, fault detection, and flow control. Session layer – manages sessions between applications. Presentation layer – responsible for data structures used by networked applications. Application layer – networked software applications such as e-mail, Telnet, and ftp. Logical grouping of information that includes a header containing control information and (usually) user data. Packets refer to network layer units of data, with messages divided into several packets. Some networks use fixed packet sizes; others use variable packet sizes. Packets typically have standard header information that identifies the packet. In contrast, frames contain only data; information about the frames transmits on the control plane. The terms datagram, frame, message, and segment describe logical information groupings at various layers of the OSI reference model and in various technology circles. - 221 - CellPipe™ IAD Series User’s Guide PPP Poisoned Reverse PVC RIP Router SNMP Subnet Mask SVC T1 TCP/IP TFTP Lucent Technologies Point-to-Point Protocol. a successor to SLIP that provides router-to-router and host-to-network connections over synchronous and asynchronous circuits. RIP feature whereby a gateway informs neighboring gateways that a particular gateway is no longer connected. To do this, the notifying gateway sets the number of hops to the unconnected gateway to a number that indicates "infinite." Since RIP allows up to 15 hops to another gateway, setting the hop count to 16 would mean "infinite." Permanent Virtual Circuit. PVCs save bandwidth associated with circuit establishment and tear down in situations where certain virtual circuits must exist all the time. Routing Information Protocol. Internet protocol used to exchange routing information within a system. RIP uses hop count as a routing metric. Network layer device that uses one or more metrics to determine the optimal path to forward network traffic. Routers forward packets from one network to another based on network layer information. A router may connect networks using various protocols by encapsulating data within another network’s packet format or by removing layers of packet formatting. Simple Network Management Protocol. Network management protocol used in TCP/IP networks. SNMP provides a way to monitor and control network devices, and to manage configurations, Statistics collection, performance, and security. 32-bit address mask that indicates the bits of an IP address used for the subnet address. Switched Virtual Circuit. Virtual circuit that is dynamically established on demand and is torn down when transmission is complete. Network connection with a capacity of 1.544 Mbps, divided into 24 separate channels (or DS0s). Protocols used for IP networks, such as the Internet, intranets, and many LANs. IP networks are connectionless, packet switching networks. Trivial File Transfer Protocol. Simplified version of FTP that transfers files from one computer to another over a network. - 222 - CellPipe™ IAD Series User’s Guide WAN Lucent Technologies Wide Area Network. Data communications network that serves users across a broad geographic area and often uses transmission devices provided by common carriers. Frame Relay is an example of a WAN. - 223 - CellPipe™ IAD Series User’s Guide ,QGH[ Adding a static route, 152 ADSL, 219; configuring, 119 Application Menu, 82; AAL Type Menu, 86; Display information Menu, 82; Set information Menu, 84 ARP, 219 ATM, 219 ATM options: configuring, 126 ATM PVCs: configuring, 122 Audio Options, 87 Auto Log off, 12 10 10/100BaseT, 219 100BaseT, 219 10BaseT ETHERNET, 207; specifications, 207 A AAL Type Menu, 86 AAL2/LES Call Control, 87; Configuration, 87; Debug Control, 88; Statistics, 90 ACOS: upgrading, 106; upgrading using TELNET, 108; upgrading using TFTP, 106 Add a Static Route, 25 Add/Change Default Route, 25 Add/Remove a Static Route, 25; Add a Static Route, 25; Add/Change Default Route, 25; Configure DHCP Client, 27; Configure DNS Client, 27; Display Route Table, 26; Remove a Route, 25; Remove the Default Route, 26 Adding a default route, 153 Adding a DLCI, 129 Adding a PVC, 122 Lucent Technologies B B8ZS, 42 BOOTP, 219 Bridge aging timer: setting, 163 Bridge configuration: Disabling RIP poisoned reverse, 164; enabling bridging, 161; Enabling STP, 166; Setting the bridge aging timer, 163 Bridging: diabling, 155; disabling by port, 156; disabling globally, 155; Enable/Disable by port, 35; enabling, 161; enabling by port, 162; enabling globally, 161 - 224 - CellPipe™ IAD Series User’s Guide MGCP/NCS Embedded Client, 75; Reports Menu, 15; Reset System, 71; System Utilities, 58 CellPipe IADs menu hierarchy, 185 Change NetMan Password, 57 Change Primary RADIUS Encryption Secret, 58 Change Primary RADIUS Server Address, 57 Change Secondary RADIUS Encryption Secret, 58 Change Secondary RADIUS Server Address, 58 Change Supervisor Password, 57 Change to E1 Mode, 43 Change to T1 Mode, 45 Change User ID, 57 Change User Password, 57 Changing: RADIUS encryption secret, 96; RADIUS server address, 95 Changing the Datalink Protocol, 110 Changing the Password, 93 Changing the RADIUS encryption secret, 96 Changing the RADIUS server address, 95 Changing the UserID, 93 Channel Configuration Menu, 43, 44 Clear ’Last Reset Reason’, 60 Clock: configuring TX source, 43 CMCP, 54; enabling/disabling, 137 Configuration, 87; CellPipe IADs, 10; Clock Source, 44; C Call Control Settings: Display IAD State, 80; Ring Test, 79; Stats Display, 79; Trace, 80 Calll Control Settings: Pick sound heard if insufficient WAN B/W to complete call, 81 CAS Signaling, 87 CellPipe IADs: configuration, 10, 24; connecting, 5; IP address of, 12; management, 208; power requirements, 208; resetting, 71; restarting, 11; specifications, 207; supported protocols, 208; upgrading ACOS, 106; upgrading system, 103; upgrading using TELNET, 104; upgrading using TFTP, 103 CellPipe IADs Main Menu: Call Control Settings, 79; VoicePath Configure, 71 CellPipe IADs Main Menu, 14; AAL2/LES Call Control, 87; Application Menu, 82; Configure DHCPServer, 62; Configure IP Router, 24; Configure LAN, 55; Configure Login, 56; Configure NAT, 66; Configure Tollbridge Voice Client, 81; Configure WAN, 38; CopperCom Call Control, 77; Derived Timing, 69; Diagnostics Menu, 70; Manage Lucent Technologies - 225 - CellPipe™ IAD Series User’s Guide DHCP, 63; DHCP Server, 62; LAN, 55; Password, 57; router, 24; SNMP, 56; T1, 42; TFTP Server, 102, 106; Transmit Channels, 42; User ID, 57; VoicePath, 71 Configure, 77 Configure ATM Options, 54; Configure F4 OAM VPI, 54; Configure Payload Scrambling, 54 Configure Bridge, 34; Configure Bridge aging timer, 35; Configure Spanning Tree Bridge Priority, 35, 36; Configure Spanning Tree Forward Delay, 36; Configure Spanning Tree Hello Time, 36; Configure Spanning Tree Max Age, 36; Configure Spanning Tree Path Cost, 37; Delete bridge Forwarding database entry, 37; Enable/Disable bridging by port, 35; Enable/Disable bridging globally, 35; Enable/Disable Spanning Tree by Port, 35; Enable/Disable Spanning Tree globally, 35 Configure Bridge Aging timer, 35 Configure Clock Source, 44 Configure Console Baud Rate, 59 Configure Console Timeout, 59 Configure datalink protocol, 39 Lucent Technologies - 226 - Configure Default Packet Size, 76 Configure DHCP: Configure DHCP Address Range Pool, 63; Configure DHCP Client Entry, 63; Configure DHCP Server Parameters, 63; Delete a DHCP Assignment Entry, 66; Delete a DHCP Client Entry, 66; Display DHCP Configuration, 64; Display DHCP Entry Details, 65; Display DHCP Server Assigned Addresses, 65; Display DHCP Server Statistics, 64; Enable/Disable DHCP, 63; Enable/Disable DHCP Debug Messages, 63 Configure DHCP Address Range Pool, 63 Configure DHCP Client, 27 Configure DHCP Client Entry, 63 Configure DHCP Relay, 27 Configure DHCP Server, 62 Configure DHCP Server Parameters, 63 Configure DLCIs, 45 Configure DNS Client, 27 Configure Echo Cancellation Default Settings, 73 Configure F4 OAM VPI, 54 Configure FR Options, 52 Configure Interface: Configure ATM Options, 54; Configure DLCIs, 45; Configure CellPipe™ IAD Series User’s Guide Enable/Disable NAT Translation by Port, 66 Configure NAT Local Server Entry, 67 Configure NAT Port Range, 67 Configure NAT TCP Timeout, 66 Configure NAT UDP Timeout, 66 Configure Payload Scrambling, 54 Configure Physical Interface, 40; ADSL mode, 40; E1 mode, 43; SDSL mode, 40; T1 mode, 42 Configure Port IP Address, 25 Configure PVCs, 47 Configure Receive Channels, 43, 44 Configure RIP Poisoned Reverse by Port, 26 Configure RIP Version by Port, 26 Configure Router: Add/Remove a Static Route, 25; Configure DHCP Relay, 27; Configure IP Filtering, 28; Configure Port IP Address, 25; Configure RIP Reverse by Port, 26; Configure RIP Version by Port, 26; Configure Telnet Server Port, 28; Display Route Table, 32; Enable/Disable RIP, 26; Unconfigure Port IP Address, 25 Configure Router Menu, 24 Configure S-Bits, 44 Configure SNMP, 55; Configure SNMP Community, 56; Configure SNMP Trap FR Options, 52; Configure PVCs, 47 Configure IP Filtering, 28 Configure LAN, 55; Set/Clear Full Duplex, 55 Configure Login: Change User password, 57 Configure Login, 56; Change Primary RADIUS Encryption Secret, 58; Change Primary RADIUS Server Address, 57; Change Secondary RADIUS Encryption Secret, 58; Change Secondary RADIUS Server Address, 58; Change Supervisor password, 57; Change User ID, 57; Display RADIUS Configuration, 58 Configure Login NetMan password, 57 Configure MGCP/NCS parameters, 75 Configure NAT, 66; Configure NAT Local Server Entry, 67; Configure NAT Port Range, 67; Configure NAT TCP Timeout, 66; Configure NAT UDP Timeout, 66; Delete IP Address from NAT Tables, 68; Delete NAT Local Server Entry, 69; Display NAT Connection Details, 68; Display NAT Connection Table, 68; Display NAT Local Server Table, 68; Display NAT Statistics, 67; Enable/Disable NAT Debug Messages, 66; Lucent Technologies - 227 - CellPipe™ IAD Series User’s Guide Host IP Address, 56; Configure System Contact, 56; Configure System Location, 56; Configure System Name, 56; Enable/Disable SNMP, 56 Configure SNMP Community, 56 Configure SNMP Trap Host IP Address, 56 Configure Spanning Tree Bridge Priority, 35, 36 Configure Spanning Tree Forward Delay, 36 Configure Spanning Tree Hello Time, 36 Configure Spanning Tree Max Age, 36 Configure Spanning Tree Path Cost, 37 Configure System Contact, 56 Configure System Location, 56 Configure System Name, 56 Configure T1/E1 Parameters: Change to E1 Mode, 43; Change to T1 Mode, 45; Configure Clock Source, 44; Configure Receive Channels, 43, 44; Configure S-Bits, 44; Configure Transmit Channels, 42, 44; Enable/Disable B8ZS, 42; Select Frame Mode, 42; Select Frame/CRC4 Mode, 43; Select Line Build Out, 42 Configure Telnet Server Port, 28 Configure Tollbridge Voice Client, 81; Debugging options, 82; Lucent Technologies - 228 - Print current configuration, 81; Set client IP address, 81; Set voice gateway IP address, 81 Configure Transmit Channels, 42, 44 Configure Tx Clock Source, 43 Configure WAN, 38; Configure datalink protocol, 39; Configure Physical Interface, 40; Quick Configuration, 39 Configuring a NAT TCP timeout, 178 Configuring a NAT UDP timeout, 179 Configuring a port IP address, 8 Configuring ATM options, 126 Configuring ATM PVCs, 122 Configuring Echo Cancellation, 142 Configuring Empty Cells, 128 Configuring fragmentation, 133 Configuring Frame Relay DLCIs, 129 Configuring Frame Relay options, 133 Configuring Payload Scrambling, 126 Configuring SNMP, 97 Configuring the ADSL interface, 119 Configuring the CellPipe IADs, 10 Configuring the DHCP address range pool, 172 Configuring the DHCP server parameters, 170 Configuring the E1 interface, 116 CellPipe™ IAD Series User’s Guide Configuring the F4 OAM Cell, 127 Configuring the Maintenance Protocol, 134, 136 Configuring the NAT local server entry, 176 Configuring the NAT port range, 180 Configuring the NAT timeouts, 177 Configuring the Physical Interface, 111 Configuring the SDSL Interface, 112 Configuring the SNMP Trap Host IP Address, 101 Configuring the System Community, 100 Configuring the System Contact, 98 Configuring the System Location, 100 Configuring the System Name, 99 Configuring the T1 interface, 113 Configuring the TFTP Server, 102, 106 Configuring the Voice Path, 138 Connecting the CellPipe IADs, 5 Connector pinouts, 210 Connectors, 3; diagram, 3 Console cable, 3 Copper Mountain CMCP: enabling/disabling, 137 CopperCom Call Control, 77; Configure, 77; Debug Control, 77; Statistics, 77 Copy file, 60 Current S-Bit Menu, 44 Lucent Technologies - 229 - D Datalink Protocol: changing, 110 DC Power Input, 3 Debug Control, 77, 88 Debug Menu, 61; Display Error Dump, 61; Enable/Disable DHCP Client debug mode, 61; Enable/Disable PPP debug mode, 61; Enable/Disable STP debug mode, 61; Set Ethernet MAC, 61 Debug MGCP/NCS, 75 Debugging options, 82 Default passwords, 6 Default User IDs, 6 Default values, 11 Delete a DHCP Assignment Entry, 66 Delete a DHCP Client Entry, 66 Delete bridge Forwarding database entry, 37 Delete IP Address from NAT Tables, 68 Delete NAT Local Server Entry, 69 Deleting a DLCI, 132 Deleting a PVC, 125 Derived Timing, 69 Derived Timing: Enable/Disable Derived Timing, 69; Enable/Disable Derived Timing Debug Messages, 69 DHCP: Configuration, 63; enabling, 169 DHCP address range pool: configuring, 172 DHCP Relayx: Configure, 27 DHCP Server configuration: CellPipe™ IAD Series User’s Guide Display Media Statistics, 18 Display Memory Statistic, 22 Display MGCP/NCS statistics, 75 Display NAT Connection Details, 68 Display NAT Connection Table, 68 Display NAT Local Server Table, 68 Display NAT Statistics, 67 Display Network Statistics, 17 Display PPP Authorization Entries, 21 Display RADIUS Configuration, 58 Display Route Table, 20, 26, 32 Display System Uptime, 21 Displaying the current configuration, 184 Displaying the RADIUS configuration, 96 DLCI, 219; adding, 129; deleting, 132; modifying, 131 Downloading an application file: verifying, 105, 108 Configuring the DHCP address range pool, 172; Configuring the DHCP server parameters, 170; Enabling DHCP, 169 DHCP server parameters: configuring, 170 Diagnostics Menu, 70 Diagnostics Menu: POTS Diagnostics, 70 Directory of all Files, 60 Disabling bridging, 155 Disabling bridging by port, 156 Disabling bridging globally, 155 Disabling RIP poisoned reverse, 164 Disabling RIP poisoned reverse by port, 165 Disabling RIP poisoned reverse globally, 164 Disabling STP, 157 Disabling STP by port, 158 Disabling STP globally, 157 Display ARP Table, 20 Display Bridge forwarding database, 20 Display Bridge status, 21 Display Current Configuration, 15 Display DHCP Configuration, 64 Display DHCP Entry Details, 65 Display DHCP Server Assigned Addresses, 65 Display DHCP Server Statistics, 64 Display Error Dump, 61 Display IAD State, 80 Display information Menu, 82 Display Interface Statistics, 18 Display Jitter Delay, 72 Lucent Technologies E E1, 219; configuring, 116 E1 Configuration Menu, 43 Echo Cancellation: configuring, 142 EEPROM, 219 Empty Cells: configuring, 128 Enable/Disable B8ZS, 42 Enable/Disable bridging by port, 35 - 230 - CellPipe™ IAD Series User’s Guide Enabling/disabling SNMP, 98 Ethernet, 219 Exiting, 12 Enable/Disable bridging globally, 35 Enable/Disable Derived Timing, 69 Enable/Disable Derived Timing Debug Messages, 69 Enable/Disable DHCP, 63 Enable/Disable DHCP Client debug mode, 61 Enable/Disable DHCP Debug Messages, 63 Enable/Disable NAT Debug Messages, 66 Enable/Disable NAT Translatio by Port, 66 Enable/Disable PPP debug mode, 61 Enable/Disable RIP, 26 Enable/Disable SNMP, 56 Enable/Disable Spanning Tree by Port, 35 Enable/Disable Spanning Tree globally, 35 Enable/Disable STP debug mode, 61 Enabling Bridging, 161 Enabling bridging by port, 162 Enabling bridging globally, 161 Enabling DHCP, 169 Enabling NAT translation, 175 Enabling RIP poisoned reverse, 148 Enabling RIP poisoned reverse by port, 149 Enabling RIP poisoned reverse globally, 148 Enabling STP, 166 Enabling STP by port, 167 Enabling STP globally, 166 Enabling/Disabling Copper Mountain CMCP, 137 Lucent Technologies F F4 OAM Cell: configuring, 127 Fast Ethernet, 219 FECN/BECN condition clear size: Setting, 54 FECN/BECN condition size: Setting, 54 FECN/BECN maximum number of bytes to store: Setting, 54 File System Menu, 60 File System Menu.Copy file, 60 File System Menu.Directory of all Files, 60 File System Menu.Format File System drive, 60 File System Menu.Remove File by name, 60 File System Menu.Rename File, 60 File System Menu.Space left in File System, 60 File Transfer Menu: File Transfer Utilities, 62; Load Boot ROM, 61; Update ACOS, 62; Update Entire System, 62 File Transfer Menu, 61 File Transfer Utilities, 62 Format File System drive, 60 Fragmentation: configuring, 133 Frame Relay, 219 Frame Relay DLCIs: configuring, 129 - 231 - CellPipe™ IAD Series User’s Guide LMI, 220 Load Boot ROM, 61 Logging on, 6; Configuring a port IP address, 8; Running the Telnet program, 9; Using a Telnet program, 7 Loop gain: setting, 144 Frame Relay Maintenance Protocol submenu, 53 Frame Relay options: configuring, 133 Frame Relay Options submenu, 52 Full Duplex, 220 G G7070 ADSL ATU-R Configuration Menu, 40 Ground start on-hook transmission: setting, 141 M MAC, 220 MAC address, 221 Main Menu: Configure SNMP, 55 Maintenance, 183 Maintenance Protocol: configuring, 134, 136 Manage MGCP/NCS Embedded Client, 75; Configure Default Packet Size, 76; Configure MGCP/NSC parameters, 75; Debug MGCP/NCS, 75; Display MGCP/NCS statistics, 75; Port Administration, 76; Remove a connection, 76 Management, 208 Menu interface, 14; deafult values, 11; exiting, 12; hierarchy, 185 Menus: Bridge Configuration Menu, 34; Channel Configuration, 44; Channel Configuration Menu, 43; Configure IP Router, 24; Current S-Bit, 44; E1 Configuration, 43; File System, 60; Frame Relay Maintenance Protocol, 53; Frame H Hard Reset or Reload ACOS from FLASH, 60 Hardware requirements, 3 I ICMP, 220 Interfaces, 3 Inverse ARP, 220 IP, 220 IP address, 220; verifying, 12 IP Filtering: Configure, 28 IP SNAP, 220 J Jitter delay: setting, 138 L LAN, 220; Configuration, 55 LAN Configuration Menu, 55 Lucent Technologies - 232 - CellPipe™ IAD Series User’s Guide Relay Options, 52; G7070 ADSL ATU-R Configuration, 40; LAN Configuration, 55; Main, 14; Reports, 15; SDSL Configuration, 40; Select Tx Clock Source, 43, 44; T1 Configuration, 42; WAN Configuration, 38; WAN Datalink Protocol Configuration, 39 Modifying a DLCI, 131 Modifying a PVC, 124 MPEG, 221 O OAM Loopback: sending, 127 Operational test, 182 OSI Reference Model, 221 P Packet, 221 Password: Configuring, 57 Passwords: default, 6 Payload Scrambling: configuring, 126 Physical interface: configuring, 111 Pick sound heard if insufficient WAN B/W to complete call, 81 Ping Utility, 59 Poisoned reverse, 222 Port Administration, 76 POTS, 207; specifications, 207 POTS Diagnostics, 70 Power Requirements, 208 Power/status Indicators, 4 Power-up test, 182 PPP, 222 Print current configuration, 81 Protocols: supported, 208 PVC, 222; adding, 122; deleting, 125; modifying, 124 N NAT configuration: Configuring a NAT TCP timeout, 178; Configuring a NAT UDP timeout, 179; Configuring the NAT local server entry, 176; Configuring the NAT port range, 180; Configuring the NAT timeouts, 177; Enabling NAT translation, 175 NAT local server entry: configuring, 176 NAT port range: configuring, 180 NAT TCP timeout: configuring, 178 NAT timeouts: configuring, 177 NAT translation: enabling, 175 NAT UDP timeout: configuring, 179 Network Interface Modules, 207 Lucent Technologies - 233 - Q Quick Configuration, 39, 120 CellPipe™ IAD Series User’s Guide Reset System, 71 Restarting CellPipe IADs, 11 Ring Test, 79 RIP, 222; Enable/Disable, 26 RIP poisoned reverse: disabling, 164; disabling by port, 165; disabling globally, 164; enabling, 148; enabling by port, 149; enabling globally, 148 RIP version: setting, 151 Route Table: Displaying, 32 Router, 222 Router configuration: Adding a default route, 153; Adding a static route, 152; Disabling bridging, 155; Disabling STP, 157; Enabling RIP poisoned reverse, 148; Setting the RIP version, 151 Running the Telnet program, 9 R RADIUS Configuration: displaying, 58 RADIUS server: changing the address, 95; changing the encryption secret, 96; displaying the configuration, 96 RADIUS Server: Changing primary address, 57; Changing primary encryption key, 58; Changing secondary address, 58; Changing secondary encryption key, 58 Receive Committed Information Rate (CIR): Setting, 45, 46 Remove a connection, 76 Remove a Route, 25 Remove File by name, 60 Remove the Default Route, 26 Rename File, 60 Reports Menu, 15; Configure Bridge, 34; Display ARP Table, 20; Display Bridge forwarding database, 20; Display Bridge status, 21; Display Current Configuration, 15; Display Interface Statistics, 18; Display Media Statistics, 18; Display Memory Statistic, 22; Display Network Statistics, 17; Display PPP Authorization Entries, 21; Display Route Table, 20; Display System Uptime, 21 Requirements: Hardware, 3; Software, 3 Lucent Technologies - 234 - S Save System Settings as Defaults, 60 SDSL, 207; configuring, 112; specifications, 207 SDSL Configuration Menu, 40 Security, 92; Changing the Password, 93; Changing the UserID, 93 Select E1 Frame Mode submenu, 43 Select Frame Mode, 42 Select Frame/CRC4 Mode, 43 Select Line Build Out, 42 CellPipe™ IAD Series User’s Guide Sending OAM Loopback, 127 Set client IP address, 81 Set Compander Mode (uLaw, A-Law), 72 Set Debug Mode, 73 Set Ethernet MAC, 61 Set information Menu, 84 Set Jitter Delay, 71 Set Loop Gain, 74 Set Max. CPS Payload, 88 Set On Hook Transmission Mode of Ground Satrt Lines, 73 Set SDSL Start Mode (Loop Start/Ground Start), 72 Set SLIC Control Mode, 72 Set System Defaults, 60 Set Voice Gateway, 71 Set voice gateway IP address, 81 Set/Clear Full Duplex, 55 Setting: FECN/BECN condition clear size, 54; FECN/BECN condition size, 54; FECN/BECN maximum number of bytes to store, 54; Receive Committed Information Rate (CIR), 45, 46; Transmit Committed Information Rate, 45, 46 Setting the bridge aging timer, 163 Setting the ground start on-hook transmission, 141 Setting the jitter delay, 138 Setting the loop gain, 144 Setting the RIP version, 151 Setting the SLIC control mode, 140 Setting the start mode, 139 Lucent Technologies - 235 - SLIC control mode: setting, 140 SNMP, 222; Configuration, 56; Configuring, 97; Configuring the System Community, 100; Configuring the System Contact, 98; Configuring the System Location, 100; Configuring the System Name, 99; Configuring the Trap Host IP Address, 101; Enabling/disabling, 98 Software requirements, 3 Space left in File System, 60 Start mode: setting, 139 Static route: adding, 152 Statistics, 77, 90 Stats Display, 79 STP: disabling, 157; disabling by port, 158; disabling globally, 157; enabling, 166; enabling by port, 167; enabling globally, 166 Submenus: Select E1 Frame Mode, 43 Subnet Mask, 222 SVC, 222 System Utilities, 58; Clear ’Last Reset Reason’, 60; Configure Console Baud Rate, 59; Configure Console Timeout, 59; Debug Menu, 61; File System Menu, 60; File Transfer Menu, 61; Hard Reset or Reload ACOS from FLASH, 60; Ping Utility, 59; Save System Settings as Defaults, 60; Set System Defaults, 60; Trace Route, 59 CellPipe™ IAD Series User’s Guide T V T1, 222; Configuration, 42; configuring, 113 T1 Configuration Menu, 42 TCP/IP, 222 TELNET: upgrading ACOS, 108; upgrading system, 104 Telnet Server Port: Configure, 28 TFTP, 102, 106, 222 TFTP Server: configuring, 102, 106 Toggle User State Control, 88 Trace, 80 Trace Route, 59 Transmit Channels: Configuration, 42 Transmit Committed Information Rate: Setting, 45, 46 Trap Host IP Address: configuring, 101 Tx Clock Source, 43, 44 Verification: Displaying the current configuration, 184; Maintenance, 183; Operational test, 182; Power-up test, 182 Verifying an IP address, 12 Voice Path: configuring, 138 VoicePath: Configuration, 71 VoicePath Configure: Configure Echo Cancellation Default Settings, 73; Display Jitter Delay, 72; Set Jitter Delay, 71 VoicePath Configure: Set Compander Mode, 72; Set Debug Mode, 73; Set Loop Gain, 74; Set On Hook Transmission Mode of Ground Satrt Lines, 73; Set SDSL Start Mode, 72; Set SLIC Control Mode, 72; Set Voice Gateway, 71 U Unconfigure Port IP Address, 25 Update ACOS, 62 Update Entire System, 62 Upgrading the CellPipe IADs software, 106 Upgrading the CellPipe IADs system, 102 User ID: Configuring, 57 User IDs: default, 6 Using a Telnet program, 7 Using a terminal emulation program: Using a terminal emulation program, 6 Lucent Technologies W WAN, 223 WAN configuration: Adding a DLCI, 129; Adding a PVC, 122; Changing the Datalink Protocol, 110; Configuring ATM options, 126; Configuring ATM PVCs, 122; Configuring Echo Cancellation, 142; Configuring Empty Cells, 128; configuring - 236 - CellPipe™ IAD Series User’s Guide Path, 138; Deleting a DLCI, 132; Deleting a PVC, 125; Enabling/Disabling Copper Mountain CMCP, 137; Modifying a DLCI, 131; Modifying a PVC, 124; Quick Configuration, 120; Sending OAM Loopback, 127; Setting the ground start on-hook transmission, 141; Setting the jitter delay, 138; Setting the loop gain, 144; Setting the SLIC control mode, 140; Setting the start mode, 139 WAN Datalink Protocol Configuration Menu, 39 fragmentation, 133; Configuring Frame Relay DLCIs, 129; Configuring Frame Relay options, 133; Configuring Payload Scrambling, 126; Configuring the ADSL interface, 119; configuring the E1 interface, 116; Configuring the F4 OAM Cell, 127; Configuring the Maintenance Protocol, 134, 136; Configuring the Physical Interface, 111; Configuring the SDSL Interface, 112; configuring the T1 interface, 113; Configuring the Voice Lucent Technologies - 237 - CellPipe™ IAD Series User’s Guide ">
/
Descargar
Solo un recordatorio amistoso. Puedes ver el documento aquí mismo. Pero lo más importante es que nuestra IA ya lo ha leído. Puede explicar cosas complejas en términos sencillos, responder a tus preguntas en cualquier idioma y ayudarte a navegar rápidamente incluso por los documentos más largos o complicados.
Anuncio