advertisement
Kam MicroGlide
Multicolour sweeping beam effects
M A N U A L V E R S I O N 1 .
0
2 0 - 0 5 - 1 6
For the latest instruction manual updates and information on the entire Kam range visit:
www.kam.co.uk
Kam products are manufactured by: Lamba plc, Unit 1, Southfields Road, Dunstable, Bedfordshire, United Kingdom LU6 3EJ
Telephone: (+44) (0)1582 690600 • Fax: (+44) (0)1582 690400 • Email: [email protected] • Web: www.lambaplc.com
If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal.
Due to continuous product development, specifications and appearance are subject to change.
XY Laser
Pan & tilt scanning colour laser
Thank you for purchasing this Kam product, we are sure that it will serve you for many years to come.
To optimise it’s performance, please read these instructions carefully to familiarise yourself with the basic operations of the unit.
Please retain them for future reference.This unit has been tested at the factory before being shipped to you. To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. To prevent a fire hazard, do not expose the unit to any naked flame sources. Unplug this apparatus during lightning storms or if it is unlikely to be used for long periods of time.
When installing the unit, please ensure you leave enough space around the unit for ventilation. Slots and openings in the unit are provided for ventilation to ensure reliable operation of the product and to protect it from overheating. To prevent fire hazard, the openings should never be blocked or covered.
The unit is powered by the mains, always handle the power cable by the plug. Never pull out the plug by pulling on the cable.
Never touch the power cable when your hands are wet as this could cause an electric shock. Do not tie a knot in the cable. The power cable should be placed such that it is not likely to be stepped on. A damaged power cable can cause a fire or give you an electrical shock. Check the power cord periodicaly, if you ever find that it is damaged, replace it before using the unit again.
Contact your retailer for a replacement.
The voltage of the available power supply differs according to country or region. Be sure that the power supply voltage of the area where this unit is to be used meets the requirements of the unit.
The lightning flash symbol inside a triangle is to alert the user to the presence high voltage within the unit’s enclosure that may be of sufficient power to constitute a risk of electrical shock to persons. Caution: to prevent the risk of electric shock, do not attempt to open the unit. No user-serviceable parts inside. Refer all servicing to qualified service personnel. The exclamation mark inside a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance.
Select the installation location of your unit carefully. Avoid placing it in direct sunlight or locations subject to vibration and excessive dust. Do not use the unit where there are extremes in temperature (below 41ºF / 5ºC or exceeding 95ºF / 35ºC).
Unpacking and safety Please unpack your new product carefully. Your new product should reach you in perfect condition.
Please check that no damage has occurred during transit. If any damage is found, do not operate your unit. Please contact the retailer you purchased it from immediately. If there is any damage to the mains cable do not use the device. Always disconnect the unit from the mains supply when carrying out any cleaning of the unit.
Manufacturer declarations
In compliance with the following requirements: RoHS Directive (2002/95/EU) and WEEE Directive (2002/96/EU).
If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal.
CE declaration of conformity
R&TTE Directive (1999/5/EU), EMC Directive (2004/108/EU), Low Voltage Directive (2006/95/EU).
The declarations are available on application from [email protected]
Before putting the devices into operation, please observe the respective country-specific regulations.
Overhead rigging
Important - the installation must be carried out by qualified service personal only. Improper installation can result in serious injuries and /or damage to property. Overhead rigging required extensive experience. Working load limits should be respected, certified installation materials should be used, the installed unit should be inspected regularly for safety. l
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing. l l l l
Locate the unit in a well ventilated spot, far away from any flammable materials and/or liquids. The fixture must be fixed at
least 50cm from surrounding walls
The device should be installed out of reach of people and outside of areas where persons may walk by or be seated.
Before rigging make sure that the installation area can hold minimum point load of 10 times the device`s weight.
The device should be well fixed; a free swinging mounting is dangerous. l l
Do not cover any ventilation opening as this may result in overheating
Before first time use, the unit should be inspected for safety. Inspection the unit regularly every year.
Packing list
Lighting unit and bracket
Power cable
Instruction manual
Warranty
AC power
The unit is supplied with a power plug appropriate to its voltage. Should any other connections be required they must be carried out with the following configuration:
Cable (EU) Cable (US) Pin International
Brown Black Live L
Light blue White Neutral N
Yellow/green Green Earth
DMX-512 connection
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first unit in a DMX chain. If you wish to connect a DMX controller with other XLR outputs you will need to use adapter cables.
DMX output
1 = Shield
2 = Signal (-) DMX input
3 = Signal (+)
Connect the DMX output of the first unit in a DMX chain with the DMX input of the next unit in the chain. Always connect the the output of one unit with the input of the next unit until all units are connected.
Unit features and connections
Key to rear panel features
Number Feature Function
1 DMX input 3 pin XLR connector for DMX512 input communication
4
5
2
3
6
7
DMX output
Power input
Power output
Rotating arm
Microphone sensor
Control panel
3 pin XLR connector for DMX512 output communication
Mains power input IEC socket
IEC connector socket for connecting multiple units for power
Lights are mounted on these arms for projection
Sensor for Sound-to-Light operation
Section for controlling unit
13
14
15
8
9
10
11
12
Menu button
Menu UP button
Menu DOWN button
ENTER button
DMX LED
Slave mode LED
Master mode LED
Sound mode LED
Cycles through the different functions
Increases parameter values
Decreases parameter values
Selects the desired function
Illumination confirmed as DMX
Illumination confirms unit is in Slave mode
Illumination confirms unit is in Master mode
Illumination confirms unit is in sound to light mode
16 LED setting display Shows the various menus and selected functions
Function setting
Using the four function buttons on the rear of the unit you can set the operating mode of the unit. Press the Menu button to display the different functions (see table below for a description of the functions). Use the Up or Down arrow buttons to make your selection. When you have chosen your desired function, press the Enter button to confirm the change.
Menu display Function
Addr DMX address setting. This is changed using the Up or Down arrow buttons (A001-A512)
ChNd
SLNd
ShNd
SoUn
SenS
Switches between 7 Channel and 13 Channel DMX operation
NASt – denotes unit is in Master mode
SLAu – denotes unit is in Slave mode
Auto – Automatic mode scrolling through built in light shows
SoUn – Sound to light mode with unit moving in time with the music
on – Sound to light mode is switched on oFF – Sound to light mode is switched off
Sound sensitivity in sound to light mode (0 = off Least sensitive 1 = least sensitive. 100 = most sensitive)
Led dISp
1tiL
2tiL test hoUr uEr rSet on – LED display remains on whilst the fixture is in use oFF – LED display goes blank whilst the fixture is in use. no – LED displays in standard orientation yes – LED display reading is rotated 180 degrees for inverted mounting
no – tilts front arm towards you as default. yes – tilts front arm away from you as default
no – tilts rear arm towards you as default. yes – tilts rear arm away from you as default
Unit runs through test cycle
Shows how many hours operation the unit has completed
Shows the version number of the unit
Resets the unit.
DMX address setting - When controlling the unit (or units) with a DMX controller, each one must be set with a specific DMX address. You can choose to set all units with the same DMX address or you can set every unit with its own DMX address. If all units are set with the same DMX address all units will be synchronised and operate in the same way.
If you set each unit with a different DMX address, they will receive the DMX signal from their own DMX address. You will now be able to control each unit individually. The DMX address that you set for each unit must be determined by the number of channels.
This unit can be operated in either 7Ch or 13Ch mode, so for example if you wish to operate in 7Ch mode, you should set the starting address of the first unit to A001, the second unit must then be set to A008 (1+7), the third to A015 (8+7), the fourth to
A022 (15+7) e.t.c.
7 Channel DMX control table
DMX channel Value Function
CH1 0-255 Tilt Motor 1 Movement 0°-135°
CH4
CH2
CH3
Strobe
CH5
CH6
CH7
Preset Shows
Show Speed
0-255
0-255
98-107
108-117
118-127
128-136
137-146
147-156
157-166
167-176
177-186
187-196
197-206
207-216
217-226
0-9
10-255
0-7
8-17
18-27
28-37
38-47
48-57
58-67
68-77
78-87
88-97
227-236
237-246
247-255
0-255
0-199
200-249
250-255
Tilt Motor 2 Movement 0°-135°
Dimmer 0-100%
Show 10
Show 11
Show 12
Show 13
Show 14
Show 15
Show 16
Show 17
Show 18
Show 19
Show 20
Show 21
Show 22
Off
Strobe speed Slow-Fast
Off
Show 1
Show 2
Show 3
Show 4
Show 5
Show 6
Show 7
Show 8
Show 9
Show 23
Show 24
Show 25
Fast – Slow
Nothing
Resets All (after 3 second valid)
Random sound activated mode
13 Channel DMX Control Table
DMX channel
CH1
CH2
Value
0-255
0-255
Function
Tilt Motor 1 Movement 0°-135°
Tilt Motor 2 Movement 0°-135°
CH3 0-255 Dimmer 0-100%
CH4
CH5
CH6
CH7
CH8
Strobe
0-9
10-255
0-255
0-255
0-255
0-255
Off
Strobe speed Slow-Fast
LED 1 Dimmer 0-100%
LED 2 Dimmer 0-100%
LED 3 Dimmer 0-100%
LED 4 Dimmer 0-100%
CH9
CH10
CH11
0-255
0-255
0-255
LED 5 Dimmer 0-100%
LED 6 Dimmer 0-100%
LED 7 Dimmer 0-100%
CH12 0-255
0-199
200-249
LED 8 Dimmer 0-100%
Nothing
Resets all after 3 seconds CH13
250-255 Random sound activated mode
Master/Slave operation
Connect the units in a Master/Slave chain via 3 pin DMX cables:
1. Connect the DMX output of the Master unit to the DMX input of the first Slave unit.
2. Next connect another DMX cable from the first Slave unit DMX output to the second Slave unit DMX input.
3. Continue in this fashion until all units are connected.
4. Set the Master unit to NASt and the second unit to SLAu
5. Slave unit will now follow the operation of the Master unit.
Product specification
Mains power / rated power AC220~240V, 50/60Hz / 46w
Control modes
Beam angle
Light source
7 or 13 channel DMX512 / Auto / Sound-to-Light / Master/Slave
75°
8 x 3w high power LED’s (2 x red, 2 x green, 2 x blue, 2 x white)
Operating temperature
DMX512 connections
0°C to 40°C
3 pins XLR male/female
Dimensions (WxDxH) 283 x 151 x 147mm (not including bracket)
Nett weight 2.5kg
Due to continuous product development, specifications and appearance are subject to change.