advertisement
▼
Scroll to page 2
of 19
5 Tebis TX100 Configurator quicklink Radio ON / OFF Input / Output products Electrical / Mechanical characteristics: see product user's instructions Product reference Description TX100 version TRE400 1 lighting output + 1 input - IP55 > V2.5.1 TRB501 1 output 10A + 1 binary input > V2.6.0 TRE400 / TRB501 1 TP device RF devices 6T 8074-02a Input Output Loads connected Visualisation system TRE400 TRB501 Summary 1. Presentation...................................................................................................................................................................... 3 1.1 General points ............................................................................................................................................................. 3 1.2 Function Description.................................................................................................................................................... 3 2. Configuration and settings ................................................................................................................................................ 5 2.1 Configuration ............................................................................................................................................................... 5 2.2 On / Off Lighting functions ........................................................................................................................................... 6 2.3 Dimmer Lighting functions ........................................................................................................................................... 8 2.4 Shutters / Blinds function........................................................................................................................................... 10 2.5 Heating / Air-Conditioning function ............................................................................................................................ 13 2.6 Scene Functions........................................................................................................................................................ 15 2.7 Repeater Function ..................................................................................................................................................... 15 3. "+ info" and "expert" mode of the TX100 ........................................................................................................................ 16 3.1 Mode + Info ............................................................................................................................................................... 16 3.2 Expert mode .............................................................................................................................................................. 16 4. Factory reset ................................................................................................................................................................... 18 4.1 Factory reset using the TX100 .................................................................................................................................. 18 4.2 Factory reset on the product...................................................................................................................................... 18 5. Main characteristics ........................................................................................................................................................ 18 TRE400 / TRB501 2 6T 8074-02a 1. Presentation 1.1 General points All the radio emitters / receivers referred to in this document are quicklink RF devices. They can be recognised by the configuration cfg push button with which they are all equipped. Quicklink indicates the configuration without tools mode. These products can also be configured to E mode by the TX100 or in S mode by ETS via the media coupler TR131. In this case, the version of the TR131 must fulfill the following characteristics: • Firmware: > 1.2.5 • Plug-in: > 1.0.11 This document describes the configuration principle with the TX100 tool and the functions available in this mode. Within the same installation, a single configuration mode may be used. To reuse with TX100, a product that has already been programmed in another installation whatever the inital configuration (quicklink , TX100 or ETS), it is necessary to carry out a factory reset on the device. Fot the combined input / output products, the factory reset will reinstall the local commands (the input of the product controls the load connected with the product). To associate a different function to these inputs with the TX100, the local control link must dirst be deleted (select the input and output numbers for the product and delete the link). Specifics of the quicklink radio emitters / receivers: All the lighting ON / OFF transmitters / receivers are operational when delivered (pre-configured). The product inputs control its output for the most commonly used function (ON / OFF control via toggle switch push button). To use the inputs with a different function, simply delete the existing link using the TX100 before reprogramming this input. 1.2 Function Description The TX100 is used to re-configure the input and output of the TRE400 or the TRB501: Description TRB501 C L N fct S1 TRE400 A B cfg A LN E1 S2 1 2 34 5 6 78 75% LED LED cfg IFW IFW fct FIJ FIJ C / 1 1 B L N A B C Button and LED configuration cfg 1 input for push button or switch Button and LED function fct TRE400 / TRB501 3 6T 8074-02a 1.2.1 Inputs The radio transmitters enable commands to be transmitted for lighting, shutters and blinds, heating / air-conditioning, and scenes. ■ Emission of commands • Lighting control • Toggle switch, ON, OFF, ON / OFF, Timer, Priority, Dimming • Shutters / Blinds control • Up, Down, Stop, Slat angle, Priority, Wind alarm, Rain alarm • 1-button control • Set point selection (Heating) • Comfort / Night set-point, Comfort, Night set-point, Frost protection / Auto, Frost protection, Auto, Standby, Comfort / Standby, Priority • Scene control 1.2.2 Outputs The main functions are the following: ■ ON / OFF The ON / OFF function is used to switch a lighting circuit ON or OFF. The command may come from switches, pushbuttons or automatic controls. ■ Status indication The Status indication function displays the status of the output contact. It allows a Toggle function to be created by sending the status indication to each push button of the group. ■ Timer The Timer function is used to switch a lighting circuit ON or OFF for an adjustable time. Depending on the operation mode selected, the output may be delayed for ON or OFF switching. The timer can be interrupted before the end of the time delay. ■ Priority The Priority function allows overriding an output to a definite status, ON or OFF. This command has the highest priority. No other command is taken into account if a priority is active. Only a priority end command re-enables the other commands. Application: maintaining lighting ON for safety reasons. ■ Scene The Scene function groups a set of outputs. These outputs can be set to an adjustable predefined status. Pressing a push button activates a scene. Each output may be integrated into 8 different scenes. TRE400 / TRB501 4 6T 8074-02a 2. Configuration and settings 2.1 Configuration These functions are available in the TX100's Standard configuration mode by creating links with the appropriate output devices. The radio emitters / receivers always function in bidirectional mode. ■ Configuration principle ➜ Programming the product: • Go to Prog mode and do a long key-press on the button of TX100 to launch the products tutorial for the installation. ➜ To number the radio inputs: • Go to the Num numbering menu ➜ Inputs ➜ , • Press on the input key to be numbered. A beep will sound when the input is detected, the configurer will automaticallu allocate a number to it, • Proceed the same way for the other inputs. ➜ To allocate a function to an input key: • Go to the Num numbering menu, • Select the number of the input key required, • Press , • Select the function and validate using TRE400 / TRB501 . 5 6T 8074-02a 2.2 On / Off Lighting functions The ON / OFF Lighting functions command the ON / OFF Lighting outputs symbolized by the display. icon on the right part of the After numbering, the functions and the links appear on the left side of the screen of the TX100. Selection of the link type to be created Prog 1 59 95 Auto All Outputs Inputs The Num symbol indicates that it is a radio input. To select the functions, switch to the numbering mode. The table here after shows all type of links compatible with the product: Possible link type ON Link description Output operation The ON function switches the lighting circuit ON. The activation of the input will cause the light to turn on. Successive activations will keep the light on. OFF The OFF function switches the lighting circuit OFF. The activation of the input will cause the light to turn off. Successive activations will keep the light off. Toggle switch The Toggle switch function allows inverting Each activation of the input caises the state of the the status of the lighting circuit. output contact to be inverted. Switch The Switch function switches the lighting circuit ON or OFF. Closing the input contact causes the light to turn on. The Timer ON function switches the lighting circuit ON for an adjustable time. Select the time delay after confirming the link: Setting range [0 s - 24 h] Timer ON TRE400 / TRB501 Opening the input contact causes the light to turn off. The activation of the input by a short key-press <1 s causes a timed illumination of the light. Interruption of the time delay: The activation of the input by a long key-press >1 s causes the time delay in progress to be stopped. Increase of the duration of the delay time: Timer commands repeated n times during the first Not active, 1 s, 2 s, 3 s, 5 s, 10 s, 15 s, 20 ten seconds after the beginning of the time delay s, multiply the duration of the time delay by n times the 30 s, 45 s, 1 min, 1 min 15 s, 1 min 30 s, value of the Timer parameter. 2 min, 2 min 30 s, 3 min, 5 min, 15 min, 20 min, 30 min, 1 h, 2 h, 3 h, 5 h, 12 h, Restart of the timer: 24 h. A command given 10 sec after the beginning of the time delay restarts the timer only once. 6 6T 8074-02a Possible link type Link description Output operation The Timer OFF function switches the lighting circuit off for an adjustable time. Select the time delay after confirming the link: Setting range [0 s - 24 h] Timer OFF The activation by short key-press <1 s causes a timed extinction of the light. Interruption of the time delay: The activation of the input by a long key-press >1 s causes the time delay in progress to be stopped. Increase of the duration of the delay time: Timer commands repeated n times during the first Not active, 1 s, 2 s, 3 s, 5 s, 10 s, 15 s, 20 ten seconds after the beginning of the time delay s, multiply the duration of the time delay by n times the 30 s, 45 s, 1 min, 1 min 15 s, 1 min 30 s, value of the Timer parameter. 2 min, 2 min 30 s, 3 min, 5 min, 15 min, 20 min, 30 min, 1 h, 2 h, 3 h, 5 h, 12 h, Restart of the timer: 24 h. A command given 10 sec after the beginning of the time delay restarts the timer only once. Closing the input contact causes the the output to be prioritised to ON. Opening the input contact causes the output's ON priority to be cancelled. Priority ON Priority is the function with the highest priority. Only a cancellation command for the priority can end the The Priority ON function forces the lighting priority and authorise other commands to be circuit ON and maintains it ON. followed again. After confirming the link, select the behaviour to follow Priority Cancellation: • Maintain: the output is maintained in the same status as during Priority. • Inversion: the output is inverted in relation to the status active during Priority. Closing the input contact causes the output priority to be switched to OFF. Opening the input contact causes the cancellation of the OFF output priority. Priority OFF The OFF Priority function forces the lighting circuit OFF and maintains it OFF. Priority is the function with the highest priority. Only a cancellation command for the priority can end the priority and authorise other commands to be followed again. After confirming the link, select the behaviour to follow Priority Cancellation: • Maintain: the output is maintained in the same status as during Priority. • Inversion: the output is inverted in relation to the status active during Priority. TRE400 / TRB501 7 6T 8074-02a 2.3 Dimmer Lighting functions The dimmer Lighting functions command the dimmer Lighting output symbolized by the icon on the right part of the display. Refer to the configuration manuals for the various dimmer Lighting output devices for information on installing and configuring these devices. After numbering the push buttons, the functions and the links available appear in the left-hand part of the TX100 screen. Selection of the link type to be created Prog X 1 59 95 Auto All Outputs Inputs The Num symbol indicates that it is a radio input. To select the functions, switch to the numbering mode. The table here after shows all type of links compatible with the product: Possible link type ON OFF Link description Output operation The ON function switches the lighting circuit ON. The OFF function switches the lighting circuit OFF. The activation of the input causes the light at the last memorised level to turn on. Successive activations keep the light at the last memorised level on. The activation of the input causes the light to be turned off to 0%. Successive activations will keep the light off. Toggle switch The activation of the input causes the change between Lighting at the last memorised level and The Toggle switch function allows inverting Off at 0%. the status of the lighting circuit. Successive activations invert the state of the output contact each time. 1 push button dimmer The activation of the input by a short key-press causes the change between Lighting at the last The 1-push button Dimmer function allows memorised level and Off at 0%. dimming the light with one single push button. The activation of the input by a long press causes the level of lighting to increase or decrease. 2 push buttons dimmer: Increase The Increase Function allows increasing the output level. 2 push buttons The Reduction function allows decreasing dimmer: Decrease the output level. Switch TRE400 / TRB501 The Switch function switches the lighting circuit ON or OFF. 8 The activation of the input by a short press causes lighting to return to the last memorised level. The activation of the input by a long press causes the lighting level to increase. The activation of the input by a short press causes the light to turn off. The activation of the input by a long press causes the lighting level to decrease. The closing of the input contact causes the lighting to return to the last memorised level. The opening of the input contact causes the light to turn off at 0%. 6T 8074-02a Possible link type Link description Output operation The Timer ON function switches the lighting circuit ON for an adjustable time. Select the time delay after confirming the link: Setting range [0 s - 24 h] Timer ON Not active, 1 s, 2 s, 3 s, 5 s, 10 s, 15 s, 20 s, 30 s, 45 s, 1 min, 1 min 15 s, 1 min 30 s, 2 min, 2 min 30 s, 3 min, 5 min, 15 min, 20 min, 30 min, 1 h, 2 h, 3 h, 5 h, 12 h, 24 h. The Timer OFF function switches the lighting circuit off for an adjustable time. Select the time delay after confirming the link: Setting range [0 s - 24 h] Timer OFF Not active, 1 s, 2 s, 3 s, 5 s, 10 s, 15 s, 20 s, 30 s, 45 s, 1 min, 1 min 15 s, 1 min 30 s, 2 min, 2 min 30 s, 3 min, 5 min, 15 min, 20 min, 30 min, 1 h, 2 h, 3 h, 5 h, 12 h, 24 h. The activation of the input by a short key-press <1 s causes a timed illumination of the light (at the last memorised level). Interruption of the time delay: The activation of the input by a long press >1 s causes the time delay in progress to stop and switching off at 0% (OFF). Increase of the duration of the delay time: Timer commands repeated n times during the first ten seconds after the beginning of the time delay multiply the duration of the time delay by n times the value of the Timer parameter. Restart of the timer: A command given 10 sec after the beginning of the time delay restarts the timer only once. The activation by short key-press <1 s causes a timed extinction of the light. Interruption of the time delay: The activation of the input by a long press >1 s causes the time delay in progress to stop and the light to turn on at the last memorised level. Increase of the duration of the delay time: Timer commands repeated n times during the first ten seconds after the beginning of the time delay multiply the duration of the time delay by n times the value of the Timer parameter. Restart of the timer: A command given 10 sec after the beginning of the time delay restarts the timer only once. Closing the input contact causes the the output to be prioritised to ON. Opening the input contact causes the output's ON priority to be cancelled. Priority ON Priority is the function with the highest priority. Only a cancellation command for the priority can end the The Priority ON function forces the lighting priority and authorise other commands to be circuit ON and maintains it ON. followed again. After confirming the link, select the behaviour to follow Priority Cancellation: • Maintain: the output is maintained in the same status as during Priority. • Inversion: the output is inverted in relation to the status active during Priority. Closing the input contact causes the output priority to be switched to OFF. Opening the input contact causes the cancellation of the OFF output priority. Priority OFF The OFF Priority function forces the lighting circuit OFF and maintains it OFF. Priority is the function with the highest priority. Only a cancellation command for the priority can end the priority and authorise other commands to be followed again. After confirming the link, select the behaviour to follow Priority Cancellation: • Maintain: the output is maintained in the same status as during Priority. • Inversion: the output is inverted in relation to the status active during Priority. TRE400 / TRB501 9 6T 8074-02a 2.4 Shutters / Blinds function The Shutters / Blinds function commands Shutters / Blinds outputs symbolized by the icon in the right part of the display. Refer to the configuration manuals for the various Shutters / Blinds output devices for information on installing and configuring these devices. After numbering the push buttons, the functions and the links available appear in the left-hand part of the TX100 screen. Selection of the link type to be created Prog 1 59 95 Auto All Inputs Num Outputs The symbol indicates that it is a radio input. To select the functions, switch to the numbering mode. The table here after shows all type of links compatible with the product: Possible link type Link description Output operation In Shutters mode*: • The activation of the input causes the timed closing of the output contact Up* (Up fonction of a shutter or blind). Up / Stop The Up / Stop function allows moving up or stopping a shutter or a blind, or inclining the slats of a blind. In Blinds mode* • The activation of the input by short key-press causes the output contact Up to close briefly (Blind slat angle function), • The activation of the input by long key-press causes the timed closing of the output contact Up (Up fonction of a shutter or blind). When a time delay is in progress, the activation of the input by a short key-press causes the contact to open (Stop function). In Shutters mode*: • The activation of the input causes the timed closing of the output contact Down* (Down function of a shutter or a blind). Down / Stop The Down function allows moving down or stopping a shutter or a blind, or inclining the slats of a blind. In Blinds mode*: • The activation of the input by a short keypress causes the output contact Down to close briefly (Blind slat angle function), • The activation of the input by long key-press causes the timed closing of the output contact Down (Up fonction of a shutter or blind). When a time delay is in progress, the activation of the input by a short key-press causes the contact to open (Stop function). Only the Shutter mode functions are active. The blind Slat angle function is not accessible. Up / Down / Stop TRE400 / TRB501 The Up / Down function allows moving up, down or stopping a shutter or a blind with one single push button. 10 Successive activations cause the Shutter mode to function following Up cycles (delayed closing of the Up output) Stop (opening of the output contacts) Down (delayed closing of the Down output)*. 6T 8074-02a Possible link type Link description Output operation Up The Up function raises a roller shutter or a blind. Closing the input contact causes the timed closing of the output contact Up (Up fonction of a shutter or blind). Down Closing the input contact causes the timed closing The Down function lowers a roller shutter of the output contact Down (Down function of a or a blind. shutter or a blind). Up / Down The Up / Down function raises or lowers a roller shutter or a blind. Down / Up Closing the input contact causes the timed closing of the output contact Down (Down function for a The Down / Up funtion is used to lower or rolling shutter or blinds) and opening the input to raise a rolling shutter or blind. contact causes the timed closing of the output contact Up (Up fonction of a shutter or blind). Closing the input contact causes the timed closing of the output contact Up (Up function for a rolling shutter or blinds) and opening the input contact causes the timed closing of the output contact Down (Down function of a shutter or a blind). The activation of the input causes the timed closing of the output contact Up (Up fonction of a shutter or blind)*. Priority is the function with the highest priority. Only a cancellation command for the priority can end the priority and authorise other commands to be followed again. Up priority The Priority up function forces the Up movement of a shutter or a blind. After confirming the link, select the behaviour to follow Priority Cancellation: • Maintain: the output is maintained in the same status as during Priority, • Inversion: the output is inverted in relation to the status active during Priority (➜ Shutter Down). A priority is also cancelled by another Priority command. The activation of the input causes the timed closing of the output contact Down (Down function of a shutter or a blind)*. Down priority The Down Priority function forces the Down movement of a shutter or a blind. Priority is the function with the highest priority. Only a cancellation command for the priority can end the priority and authorise other commands to be followed again. After confirming the link, select the behaviour to follow Priority Cancellation: • Maintain: the output is maintained in the same status as during Priority, • Inversion: the output is inverted in relation to the status active during Priority (➜ Shutter up). A priority is also cancelled by another Priority command. * The modes and delay durations are parameterisable (see the TX100 configuration manuals for the Shutter / Blind output actuators). Possible link type Wind alarm* TRE400 / TRB501 Link description Output operation The Wind alarm function enables alarms to be sent from automatic controls. 11 When the input contact is closed, the information Alarm active (1) is sent. When the input contact is opened, the information Alarm inactive (0) is sent. 6T 8074-02a Rain alarm* The Rain alarm function enables alarms to be sent from automatic controls. When the input contact is closed, the information Alarm active (1) is sent. When the input contact is opened, the information Alarm inactive (0) is sent. * These functions have the highest priority. The Wind alarm function has a higher priority than the rain alarm function. No other command is taken into consideration if an Alarm is active. Only the end of the alarm enables again the other commands. TRE400 / TRB501 12 6T 8074-02a 2.5 Heating / Air-Conditioning function The Heating / Air-Conditioning functions command a thermostat or a regulator symbolized by the display. icon on the right part of the Refer to the thermostat, ambiance controller and regulator configuration manuals for information on installing and configuring these devices. Selection of the link type to be created Prog 1 95 Auto All Inputs The Num Outputs symbol indicates that it is a radio input. To select the functions, switch to the numbering mode. The table here after shows all type of links compatible with the product: Possible link type Link description Output operation The associated input contact is a switch or an output from a programming clock. Comfort / Night set-point The function Comfort / Night set-point enables switching between the Comfort and Night set-point modes. Closing the contact causes Comfort mode to be activated. Opening the contact causes Night set-point mode to be activated. The effect of this command is cancelled by any other mode activation command. Override in comfort mode Override in Economy mode The function "Override in comfort mode" activates the Comfort mode. The function "Override in economy mode" activates the economy mode. Closing the input contact causes Comfort mode to be activated. The effect of this command is cancelled by any other mode activation command. Closing the input contact causes Night set-point mode to be activated. The effect of this command is cancelled by any other mode activation command. The associated input contact is a switch or an output from a programming clock. auto Frost protection / Auto The Frost protection / Auto function enables switching between the Frost protection and Automatic modes. Closing the contact causes the Frost protection mode to be activated. Opening the contact causes a return to Automatic mode. The effect of this command is cancelled by any other mode activation command. Frost protection override TRE400 / TRB501 The Frost protection override function is used to activate the Frost protection functon in the case of heating or the Protection mode in the case of air conditioning. 13 Closing the input contact causes the Frost protection mode to be activated (Protection in case of air-con). The effect of this command is cancelled by any other mode activation command. 6T 8074-02a Possible link type Auto (Return home) Standby override Link description Output operation The Auto function cancels the override in progress to return to the set point corresponding to Automatic mode. The Standby override funtion is used to activate Standby mode. The Comfort / Standby function enables Comfort / Standby switching between the Comfort and Standby modes. Closing the input contact causes Auto mode to be activated. The effect of this command is cancelled by any other mode activation command. Closing the input contact causes Standby mode to be activated. The effect of this command is cancelled by any other mode activation command. Closing the input contact causes the setpoint to switch between Comfort and Standby. The setpoint changes each time the input contact is closed. The effect of this command is cancelled by any other mode activation command. The associated input contact is a switch or an output from a programming clock. Closing the contact causes the activation and maintenance of Comfort mode. Opening the contact causes the cancellation of the priority and the return to the normally active mode. Comfort Priority The Comfort Priority function is used to activate and maintain Comfort mode. The Comfort Priority function is a function with a higher priority than the override or time delay commands. Only a cancellation command for the priority can end the priority and authorise other commands to be followed again. The effect of the command is cancelled by any other priority command (Night set-point, Frost protection) or by a Stop or Windows contact command. The associated input contact is a switch or an output from a programming clock. Priority frost protection The Frost protection override function is used to activate the Frost protection functon in the case of heating or the Protection mode in the case of air conditioning. Closing the contact causes Frost protection mode to be activated and maintained (Protection in case of air-con). Opening the contact causes the cancellation of the priority and the return to the normally active mode. The Priority frost protection function is a function with a higher priority than override or time delay commands. Only a cancellation command for the priority can end the priority and authorise other commands to be followed again. The effect of the command is cancelled by any other priority command (Night set-point, Frost protection) or by a Stop or Windows contact command. TRE400 / TRB501 14 6T 8074-02a 2.6 Scene Functions ■ Link creation The Scene function groups a set of outputs. These outputs can be set to an adjustable predefined status. Pressing a push button activates a scene. Each output may be integrated into 8 different scenes. It is possible to create links between a push-button and the outputs which are to be part of the scene by selecting a Scene function (number 1 to 8). Easy Prog Selection of the link type to be created 3 21 6 29 Auto Possible link type ... Scene 1 to 8 26 Expert Link description Num Output operation The Scene function groups a set of outputs. The status of each output can be defined: These outputs can be set to an adjustable - By output settings, predefined status. - Via learning, with the push buttons on the insPressing a push button activates a scene. tallation or on the front of certain devices. Each output may be integrated into 8 different scenes. ■ Learning and memorisation of scenes This procedure enables a scene to be modified and memorised by locally using the push buttons in the room, on a remote control RF. • Activate the scene with a short key-press on the transmitter that launches the scene, • Put the outputs (Lighting, Shutters, Thermostat, etc.) into the sesired status using the usual local controls (push button, remote control, etc.), • Memorise the status of the inputs with a long key-press greater than 5s on the transmitter that launches the scene. The memorisation is indicated by the momentary activation of the outputs. 2.7 Repeater Function It increases the radio range of the system by re-sending the messages received by the product. Inactive by default, the Repeater function can be activated from the Product Management / TX100 Repeater menu. TRE400 / TRB501 15 6T 8074-02a 3. "+ info" and "expert" mode of the TX100 3.1 Mode + Info The mode +Info can be accessed in the Prog and Visu modes of the TX100. This display mode is active for the installation products until it is deactivated. Prog 1 Auto Visu 1 + info 1 Num Auto + info Outputs The +Info mode allows the status indication to be linked from an output to a viewing product: Area controller, LED output, etc. The status indication sends the current status over the network each time the status changes. 1 The status indication is represented by the symbol . The status indication adds itself to the list of inputs on the left of the TX100 screen with the same number as the output. 3.2 Expert mode ■ General points The Expert mode allows: • Non-configurable KNX products to be integrated by ETS (viewing tool, Internet gateway, domovea) in the installation, • Specific links, not available in the Standard configuration mode, to be created. In Expert mode, the functions are displayed through the communication objects used in the configuration ETS mode. The objects appear as a list located under the input and output numbers. Expert prog 11 11 OnOff OnOff Timer Timer Forced Forced Scene Scene On Off Standard The Expert mode allows links to be established between objects with the same format by giving them the same group address. TRE400 / TRB501 16 6T 8074-02a ■ List of the available objects On / Off and Dimmer Lighting controls Designation TX100 Designation ETS Function Format Description OnOff On/Off ON / OFF EIS1 1 bit Allows an ON / OFF command to be transmitted. IOnOff InfoOn/Off ON / OFF information EIS1 1 bit Indicates the output's status. DimCtrl DimmingCtrl Dimming command 1 bit Allows changing the output level of a dimmer. Timer TimedStartstop Timer EIS1 1 bit Allows you to activate or interrupt the timer. Forced Forced Priority EIS2 2 bit Forces an output. Shutters / Blinds control Designation TX100 Designation ETS Function Format Description StepStop StepStop Slat angle 1 bit Sends a slat angle command for a blind. UpDown UpDown Up / Down 1 bit Sends an Up or Down command for a roller shutter or a blind. IUpDown InfoMoveUpDown Up / Down information 1 bit Provides the status of the Up / Down output (control 1 BP). Forced Forced Priority EIS2 2 bit Forces an Up or Down command. Wind Alm Wind Alm Wind alarm 1 bit The WindAlm object enables the wind alarm to be activated. RainAlm RainAlm Rain alarm 1 bit The RainAlm object enables the rain alarm to be activated. Heating / Air-Conditioning control Designation TX100 Designation ETS Function Format Description HvacMode HvacMode Heating mode 1 byte Activates a heating or air-conditioning mode (Comfort, Reduced, ...). IOnOff InfoOn/Off ON / OFF information EIS1 1 bit Indicates the output's status. Timer TimedStartstop Timer EIS1 1 bit Starts a delayed deviation. Forced Forced Priority EIS2 2 bit Forces a heating or air-conditioning mode. Scene Designation TX100 Scene TRE400 / TRB501 Designation ETS SceneNumber Function Format Scene 1 byte 17 Description Activates the scene by its number. 6T 8074-02a 4. Factory reset This function enables the device to be returned to its initial configuration (configuration when it came out of the factory). After a device reset, the device can be re-used in a new installation. The factory reset can either be performed directly on the product, or using the TX100 Product Management / Factory Reset menu. The latter solution is recommended if the product is part of the installation configured by TX100. This function is started by the Slat angle / Stop objectOperating modesRight 4.1 Factory reset using the TX100 The device belongs to the installation: it appears in the Reset menu's list of devices that can be reset to Factory configuration. • Select the product in the list, • Press and confirm the erasing. After a device reset, the installation must be learnt again in order to relocate the devices reset to Factory configuration. 4.2 Factory reset on the product The factory reset can be performed on the product, if the data of the TX100 project has been lost or if the product is not part of the installation. Factory reset on the product: • Press and hold the "Cfg" button (> 10 seconds), release the button as soon as the "Cfg" LED starts to flash, • Wait for the "Cfg" LED to go out, indicating that the factory reset is complete. To reuse with TX100, a product that has already been programmed in another installation whatever the inital configuration (quicklink , TX100 or ETS), it is necessary to carry out a factory reset on the device. Fot the combined input / output products, the factory reset will reinstall the local commands (the input of the product controls the load connected with the product). To associate a different function to these inputs with the TX100, the local control link must dirst be deleted (select the input and output numbers for the product and delete the link). 5. Main characteristics Product TRE400 / TRB501 Max. number of group addresses 87 Max. number of links 95 TRE400 / TRB501 18 6T 8074-02a TRE400 / TRB501 19 6T 8074-02a
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement