TPLP Pre-Assembled Low Profile Evaporators PRODUCT DATA & INSTALLATION Bulletin T30-TPLP-PDI-11 Part #1087152 PRODUCT SUPPORT web: t-rp.com/tplp email: [email protected] call: 1-844-893-3222 x520 scan: Air & Electric Defrost Electrical Power: 115/1/60, 208-230/1/60, 208-230/3/60, 460/1/60 See Page 22 for details CONTENTS Page Nomenclature...................................................................................................................2 Features & Options.......................................................................................................... 2 Pre-Assembled Features................................................................................................. 3 Capacity Data.................................................................................................................. 4 Electrical Data.................................................................................................................. 5-7 Wiring Diagrams - Models with standard PSC motors .................................................... 8-15 Wiring Diagrams - Models with optional EC Motors / .............................. 16-19 Shipping Weights............................................................................................................. 20 Dimensional Data.............................................................................................................21-22 Recommended Expansion Valve Selections................................................................... 23 Installation Instructions....................................................................................................24-25 Project Information.......................................................................................................... 26 Product Support Resources: Service Parts, Troubleshooting, Warranty, etc................. 27 “As Built” Service Parts....................................................................................................Back 23/06/17 NOMENCLATURE T P LP 3 15 L E S2 B R6 - PSC Motor Designation: PSC = PSC EC2 = SmartSpeed ECM T = Trenton Pre-Assembled Refrigerant Designation: R2 = R407A / R407C / R22 / R448A R6 = R404A R7 = R407A / R448A Low Profile Evaporator Number of Fans Generation: Nominal Capacity: x 1000 @ 10°F TD, Btu/H, R404A B = 2nd Voltage: S1 = 115/1/60 (air defrost models only) S2 = 208-230/1/60 S4 = 460/1/60 (2 to 6 fan models only) T3 = 208-230/3/60 Application Range: M = Medium to High Temp 6 FPI (10°F to 45°F (-12°C to 7°C) Evap Temp) L = Low Temp 6 FPI (-40°F to 0°F(-40°C to -17°C) Evap Temp) V = Low Temp 4 FPI (-40°F to 0°F (-40°C to -17°C) Evap Temp) Defrost*: A = Air E = Electric STANDARD FEATURES • Compitable with Low GWP Refrigerants • Schrader valve on suction header • High efficiency and high strength fan guard • Positive slope, hinged drain pan • Front access • Central drain connections (approximate) • Internally enhanced tubing • Universal drain fitting • Convenient mounting brackets • Large 3/4” ID (3/4” MPT) drain hole • Ample electrical and header compartments • Factory installed expansion valve, • PSC Motors solenoid valve and room thermostat • Liquid line solenoid valve wire harness factory installed AVAILABLE OPTIONS • EC motors with patented SmartSpeed® Technology. See page 16 • Corrosion protection: alternate fin materials and coatings • Hot gas loop pan with hot gas defrost models • Additional options available, please contact factory • Factory installed expansion valve, solenoid valve and room thermostat • Wire fan guard T30-TPLP-PDI-11 -2- 23/06/17 TPLP PRE-ASSEMBLED FEATURES 60Hz Thermostat Mounted on Front of Unit Solenoid Valve and TXV Mounted Solenoid Valve Wire pulled through and labeled on each end Schrader Valve Located Outside T30-TPLP-PDI-11 -3- 23/06/17 TPLP 60Hz CAPACITY DATA - ALL MODELS Medium Temperature Models - Capacity @ 6 F.P.I. * Medium Temp. Models TPLP Number Of Fans R407A R448A Evap R407C Capacity Temp. BTUH 25°F R404A (WATTS) (-4°C) R507 R22 Air Flow CFM (L/S) Refrigerant ** Charge R407A LB. (KG) 104M 1 4090 (1197) 3870 (1134) 4300 (1260) 4090 (1197) 1010 (477) 0.7 (0.3) 106M 1 5230 (1530) 4950 (1449) 5500 (1610) 5230 (1530) 950 (458) 1.1 (0.5) 107M 1 6460 (1891) 6120 (1791) 6800 (1990) 6460 (1891) 900 (425) 1.5 (0.7) 209M 2 8170 (2394) 7740 (2268) 8600 (2520) 8170 (2394) 2020 (953) 1.3 (0.6) 211M 2 10450 (3059) 9900 (2898) 11000 (3220) 10500 (3059) 1910 (901) 1.4 (0.6) 214M 2 13300 (3895) 12600 (3690) 14000 (4100) 13300 (3895) 1800 (850) 2.0 (0.9) 317M 3 16200 (4731) 15400 (4482) 17000 (4980) 16200 (4731) 2860 (1350) 3.0 (1.4) 320M 3 19000 (5567) 18100 (5274) 20000 (5860) 19000 (5567) 2700 (1274) 4.0 (1.8) 423M 4 21900 (6403) 20800 (6066) 23000 (6740) 21900 (6403) 3810 (1798) 3.9 (1.8) 426M 4 24700 (7230) 23500 (6849) 26000 (7610) 24700 (7230) 3600 (1699) 3.3 (1.5) 532M 5 30400 (8902) 28900 (8433) 32000 (9370) 30400 (8902) 4500 (2124) 6.5 (2.9) 639M 6 37100 (10830) 35200 (10260) 39000 (11400) 37100 (10830) 5400 (2549) 7.8 (3.5) 314L 3 13300 (3895) 14000 (4100) 2860 (1350) 3.0 (1.4) 317L 3 16200 (4731) 17000 (4980) 2700 (1274) 4.0 (1.8) 419L 4 18100 (5292) 19000 (5570) 3810 (1798) 3.9 (1.8) 422L 4 20900 (6118) 22000 (6440) 3600 (1699) 3.3 (1.5) 527L 5 25700 (7515) 27000 (7910) 4500 (2124) 6.5 (2.9) 631L 6 29500 (8626) 31000 (9080) 5400 (2549) 7.8 (3.5) 312V 3 11400 (3344) 12000 (3520) 2860 (1350) 3.0 (1.4) 315V 3 14300 (4171) 15000 (4390) 2700 (1274) 4.0 (1.8) 416V 4 15200 (4456) 16000 (4690) 3810 (1798) 3.9 (1.8) 419V 4 18100 (5292) 19000 (5570) 3600 (1699) 3.3 (1.5) 523V 5 21900 (6403) 23000 (6740) 4500 (2124) 6.5 (2.9) 627V 6 25700 (7515) 27000 (7910) 5400 (2549) 7.8 (3.5) Low Temperature Models - Capacity @ 6 F.P.I. * Low Temp. Models TPLP Number Of Fans Evap R407A Capacity Temp. R448A BTUH -20°F R404A (WATTS) (-29°C) R507 Air Flow 104L 1 3610 (1055) 3800 (1110) 1010 (477) 0.7 (0.3) CFM (L/S) Refrigerant ** Charge R407A LB. (KG) 105L 1 4560 (1340) 4800 (1410) 950 (458) 1.1 (0.5) 106L 1 5510 (1615) 5800 (1700) 900 (425) 1.5 (0.7) 207L 2 7030 (2062) 7400 (2170) 2020 (953) 1.3 (0.6) 209L 2 8550 (2508) 9000 (2640) 1910 (901) 1.4 (0.6) 211L 2 10500 (3059) 11000 (3220) 1800 (850) 2.0 (0.9) Low Temperature Models - Capacity @ 4 F.P.I. * Low Temp. 4 FPI Models TPLP Number Of Fans Evap R407A Capacity Temp. R448A BTUH -20°F R404A (WATTS) (-29°C) R507 Air Flow CFM (L/S) Refrigerant ** Charge R407A LB. (KG) 103V 1 2850 (836) 3000 (880) 1010 (477) 0.7 (0.3) 104V 1 3900 (1140) 4100 (1200) 950 (458) 1.1 (0.5) 105V 1 4750 (1397) 5000 (1470) 900 (425) 1.5 (0.7) 206V 2 6080 (1786) 6400 (1880) 2020 (953) 1.3 (0.6) 208V 2 7410 (2176) 7800 (2290) 1910 (901) 1.4 (0.6) 209V 2 8840 (2584) 9300 (2720) 1800 (850) 2.0 (0.9) Capacities rated using 10°F (5.6°C) TD & 100°F (38°C) liquid temperature. Capacities at other TD within a range of 8 to 15 °F (4.4 to 8.3°C) are directly proportional to TD, or use formula: Capacity = Rated capacity ÷ 10 x TD. For capacities at TD outside of range 8 to 15 °F (4.4 to 8.3°C), or liquid temperature lower than 75°F (24°), consult factory. Capacities for R448A, R407A and R407C are based on mean temperature. Mean temperature is the average temperature between the saturated suction temperature and the temperature feeding the evaporator. For dew point ratings, consult factory. For R449A, use R448A data. * CAPACITY CORRECTION FACTORS FOR LOW TEMPERATURE UNITS SATURATED SUCTION TEMPERATURE °F (°C) 0 (-17.8) -10 (23.3) -20 (-28.9) -30 (-34.4) -40 (-40) FACTOR 1.06 1.03 1.0 0.92 0.85 ** REFRIGERANT CHARGE CONVERSION FACTORS R448A R407C R404A R507 R22 R134a 0.96 0.99 0.92 0.93 1.02 1.03 NO CORRECTION FACTOR REQUIRED FOR MEDIUM TEMP. UNITS T30-TPLP-PDI-11 -4- 23/06/17 TPLP 60Hz ELECTRICAL DATA 115/1/60 - AIR DEFROST MODELS FAN MOTORS MODEL FPI PSC MOTORS TPLP QTY. 104MAS1 106MAS1 107MAS1 209MAS1 211MAS1 214MAS1 317MAS1 320MAS1 423MAS1 426MAS1 532MAS1 639MAS1 1 1 1 2 2 2 3 3 4 4 5 6 6 HP 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 FLA TOTAL 1.0 1.0 1.0 2.0 2.0 2.0 3.0 3.0 4.0 4.0 5.0 6.0 EC MOTORS MIN. CIRC. MAX. FUSE WATTS AMPACITY (A) (AMPS) 100 1.3 15 100 1.3 15 100 1.3 15 200 2.3 15 200 2.3 15 200 2.3 15 300 3.3 15 300 3.3 15 400 4.3 15 400 4.3 15 500 5.3 15 600 6.3 15 HP 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 FLA TOTAL 1.0 1.0 1.0 2.0 2.0 2.0 3.0 3.0 4.0 4.0 5.0 6.0 WATTS 60 60 60 120 120 120 180 180 240 240 300 360 MIN. CIRC. MAX. FUSE AMPACITY (A) (AMPS) 1.3 15 1.3 15 1.3 15 2.3 15 2.3 15 2.3 15 3.3 15 3.3 15 4.3 15 4.3 15 5.3 15 6.3 15 ELECTRICAL DATA 208-230/1/60 - AIR DEFROST MODELS FAN MOTORS MODEL FPI PSC MOTORS TPLP QTY. 104MAS2 106MAS2 107MAS2 209MAS2 211MAS2 214MAS2 317MAS2 320MAS2 423MAS2 426MAS2 532MAS2 639MAS2 1 1 1 2 2 2 3 3 4 4 5 6 6 HP 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 FLA TOTAL 0.5 0.5 0.5 1.0 1.0 1.0 1.5 1.5 2.0 2.0 2.5 3.0 WATTS 100 100 100 200 200 200 300 300 400 400 500 600 EC MOTORS MIN. CIRC. MAX. FUSE AMPACITY (A) (AMPS) 0.6 15 0.6 15 0.6 15 1.1 15 1.1 15 1.1 15 1.6 15 1.6 15 2.1 15 2.1 15 2.6 15 3.1 15 HP 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 FLA TOTAL 0.6 0.6 0.6 1.2 1.2 1.2 1.8 1.8 2.4 2.4 3.0 3.6 WATTS 60 60 60 120 120 120 180 180 240 240 300 360 MIN. CIRC. MAX. FUSE AMPACITY (A) (AMPS) 0.8 15 0.8 15 0.8 15 1.4 15 1.4 15 1.4 15 2.0 15 2.0 15 2.6 15 2.6 15 3.2 15 3.8 15 ELECTRICAL DATA 460/1/60 - AIR DEFROST MODELS FAN MOTORS MODEL FPI T30-TPLP-PDI-11 PSC MOTORS TPLP QUANTITY 209MAS4 211MAS4 214MAS4 317MAS4 320MAS4 423MAS4 426MAS4 532MAS4 639MAS4 2 2 2 3 3 4 4 5 6 6 HP 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 FLA TOTAL 0.8 0.8 0.8 1.2 1.2 1.6 1.6 2.0 2.4 -5- WATTS 200 200 200 300 300 400 400 500 600 MIN. CIRC. MAX. FUSE AMPACITY (A) (AMPS) 0.9 15 0.9 15 0.9 15 1.3 15 1.3 15 1.7 15 1.7 15 2.1 15 2.5 15 23/06/17 TPLP FAN MOTORS MODEL PSC MOTORS FPI 60Hz ELECTRICAL DATA 208-230/1/60 & 208-230/3/60 ELECTRIC DEFROST MODELS TPLP QTY. 104ME* 106ME* 107ME* 1 1 1 DEFROST HEATERS EC MOTORS MAX. FLA MCA HP WATTS FUSE TOTAL (A) (AMPS) 1/15 0.5 100 0.6 15 1/15 0.5 100 0.6 15 1/15 0.5 100 0.6 15 208-230/1/60 208-230/3/60 MAX. TOTAL MAX. MAX. FLA MCA TOTAL MCA TOTAL MCA HP WATTS FUSE WATTS FUSE FUSE TOTAL (A) AMPS (A) AMPS (A) (AMPS) (AMPS) (AMPS) 1/15 0.6 60 0.8 15 1060 4.6 5.8 15 3.0 3.8 15 1/15 0.6 60 0.8 15 1060 4.6 5.8 15 3.0 3.8 15 1/15 0.6 60 0.8 15 1060 4.6 5.8 15 3.0 3.8 15 209ME* 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 211ME* 214ME* 2 2 1/15 1/15 1.0 1.0 200 200 1.1 1.1 15 15 1/15 1/15 1.2 1.2 120 120 1.4 1.4 15 15 1890 1890 8.2 8.2 10.3 10.3 15 15 5.3 5.3 6.7 6.7 15 15 3 3 1/15 1/15 1.5 1.5 300 300 1.6 1.6 15 15 1/15 1/15 1.8 1.8 180 180 2.0 2.0 15 15 2730 2730 11.9 11.9 14.8 14.8 15 15 7.7 7.7 10 10 15 15 423ME* 426ME* 4 4 1/15 1/15 2.0 2.0 400 400 2.1 2.1 15 15 1/15 1/15 2.4 2.4 240 240 2.6 2.6 15 15 3560 3560 15.5 15.5 19.3 19.3 20 20 10 10 12 12 15 15 532ME* 5 1/15 2.5 500 2.6 15 1/15 3.0 300 3.2 15 4400 19.1 23.9 25 12 15.1 20 639ME* 6 1/15 3.0 600 3.1 15 1/15 3.6 360 3.8 15 5230 22.7 28.4 30 15 18 20 104LE* 105LE* 1 1 1/15 1/15 0.5 0.5 100 100 0.6 0.6 15 15 1/15 1/15 0.6 0.6 60 60 0.75 0.75 15 15 1060 1060 4.6 4.6 5.8 5.8 15 15 3.0 3.0 3.8 3.8 15 15 106LE* 1 1/15 0.5 100 0.6 15 1/15 0.6 60 0.75 15 1060 4.6 5.8 15 3.0 3.8 15 207LE* 209LE* 2 2 1/15 1/15 1.0 1.0 200 200 1.1 1.1 15 15 1/15 1/15 1.2 1.2 120 120 1.4 1.4 15 15 1890 1890 8.2 8.2 10.3 10.3 15 15 5.3 5.3 6.7 6.7 15 15 2 1/15 1.0 200 1.1 15 1/15 1.2 120 1.4 15 1890 8.2 10.3 15 5.3 6.7 15 3 3 4 4 1/15 1/15 1/15 1/15 1.5 1.5 2.0 2.0 300 300 400 400 1.6 1.6 2.1 2.1 15 15 15 15 1/15 1/15 1/15 1/15 1.8 1.8 2.4 2.4 180 180 240 240 2.0 2.0 2.6 2.6 15 15 15 15 2730 2730 3560 3560 11.9 11.9 15.5 15.5 14.8 14.8 19.3 19.3 15 15 20 20 7.7 7.7 10 10 10 10 12 12 15 15 15 15 527LE* 631LE* 103VE* 104VE* 105VE* 5 6 1 1 1 1/15 1/15 1/15 1/15 1/15 2.5 3.0 0.5 0.5 0.5 500 600 100 100 100 2.6 3.1 0.6 0.6 0.6 15 15 15 15 15 1/15 1/15 1/15 1/15 1/15 3.0 3.6 0.6 0.6 0.6 300 360 60 60 60 3.2 3.8 0.75 0.75 0.75 15 15 15 15 15 4400 5230 1060 1060 1060 19.1 22.7 4.6 4.6 4.6 23.9 28.4 5.8 5.8 5.8 25 30 15 15 15 12 15 3.0 3.0 3.0 15.1 18 3.8 3.8 3.8 20 20 15 15 15 206VE* 208VE* 209VE* 2 2 2 1/15 1/15 1/15 1.0 1.0 1.0 200 200 200 1.1 1.1 1.1 15 15 15 1/15 1/15 1/15 1.2 1.2 1.2 120 120 120 1.4 1.4 1.4 15 15 15 1890 1890 1890 8.2 8.2 8.2 10.3 10.3 10.3 15 15 15 5.3 5.3 5.3 6.7 6.7 6.7 15 15 15 3 3 1/15 1/15 1.5 1.5 300 300 1.6 1.6 15 15 1/15 1/15 1.8 1.8 180 180 2.0 2.0 15 15 2730 2730 11.9 11.9 14.8 14.8 15 15 7.7 7.7 10 10 15 15 416VE* 419VE* 4 4 1/15 1/15 2.0 2.0 400 400 2.1 2.1 15 15 1/15 1/15 2.4 2.4 240 240 2.6 2.6 15 15 3560 3560 15.5 15.5 19.3 19.3 20 20 10 10 12 12 15 15 523VE* 627VE* 5 6 1/15 1/15 2.5 3.0 500 600 2.6 3.1 15 15 1/15 1/15 3.0 3.6 300 360 3.2 3.8 15 15 4400 5230 19.1 22.7 23.9 28.4 25 30 12 15 15.1 18 20 20 317ME* 320ME* 211LE* 314LE* 317LE* 419LE* 422LE* 312VE* 315VE* 6 6 4 * = S2 or T3. Refer to Nomenclature for details T30-TPLP-PDI-11 -6- 23/06/17 TPLP FAN MOTORS MODEL FPI QTY. 209MES4 211MES4 214MES4 317MES4 320MES4 423MES4 426MES4 532MES4 639MES4 207LES4 209LES4 211LES4 314LES4 317LES4 419LES4 422LES4 527LES4 631LES4 206VES4 208VES4 209VES4 312VES4 315VES4 416VES4 419VES4 523VES4 627VES4 2 2 2 3 3 4 4 5 6 2 2 2 3 3 4 4 5 6 2 2 2 3 3 4 4 5 6 6 6 4 DEFROST HEATERS PSC MOTORS TPLP T30-TPLP-PDI-11 60Hz ELECTRICAL DATA - 460/1/60 ELECTRIC DEFROST MODELS HP 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 1/15 FLA TOTAL 0.8 0.8 0.8 1.2 1.2 1.6 1.6 2.0 2.4 0.8 0.8 0.8 1.2 1.2 1.6 1.6 2.0 2.4 0.8 0.8 0.8 1.2 1.2 1.6 1.6 2.0 2.4 WATTS 200 200 200 300 300 400 400 500 600 200 200 200 300 300 400 400 500 600 200 200 200 300 300 400 400 500 600 MCA (A) 0.9 0.9 0.9 1.3 1.3 1.7 1.7 2.1 2.5 0.9 0.9 0.9 1.3 1.3 1.7 1.7 2.1 2.5 0.9 0.9 0.9 1.3 1.3 1.7 1.7 2.1 2.5 -7- MAX. FUSE (AMPS) 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 TOTAL WATTS TOTAL AMPS MCA (A) MAX. FUSE (AMPS) 1890 1890 1890 2730 2730 3560 3560 4400 5230 1890 1890 1890 2730 2730 3560 3560 4400 5230 1890 1890 1890 2730 2730 3560 3560 4400 5230 4.1 4.1 4.1 5.9 5.9 7.7 7.7 9.6 11.4 4.1 4.1 4.1 5.9 5.9 7.7 7.7 9.6 11.4 4.1 4.1 4.1 5.9 5.9 7.7 7.7 9.6 11.4 5.1 5.1 5.1 7.4 7.4 9.7 9.7 12.0 14.2 5.1 5.1 5.1 7.4 7.4 9.7 9.7 12.0 14.2 5.1 5.1 5.1 7.4 7.4 9.7 9.7 12.0 14.2 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 23/06/17 TPLP PSC 60Hz WIRING DIAGRAM - 115/1/60, 208-230/1/60 STANDARD PSC MOTORS AIR DEFROST MODELS WITHOUT DEFROST TIME CLOCK WITH DEFROST TIME CLOCK REFER TO EVAPORATOR NAMEPLATE FOR ELECTRICAL REQUIREMENTS L1 DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT REFER TO EVAPORATOR NAMEPLATE FOR ELECTRICAL REQUIREMENTS L1 L2(N) L2(N) GND GND TM 3 4 X 2 1 FUSE OR CIRCUIT BREAKER NOTE #3 FUSE OR CIRCUIT BREAKER NOTE #3 N OMIT 2ND FUSE IF(N) OMIT 2ND FUSE IF(N) GND F 4 TO MULTIPLE EVAPS (IF APPLIC) F 4 PUMP DOWN SWITCH (IF USED) TO MULTIPLE EVAPORATORS (IF APPLIC) SPACE THERMOSTAT NOTE #4 LIQUID LINE SOLENOID VALVE NOTE #4 LIQUID LINE SOLENOID VALVE NOTE #4 SPACE THERMOSTAT NOTE #4 N.C. N.C. EVAPORATOR EVAPORATOR 4 F 4 TERMINAL BOARD F TERMINAL BOARD GND. GND. FAN MOTOR POWER PLUGS FAN MOTOR POWER PLUGS FAN MTR FAN MTR FAN MTR REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY FAN MTR FAN MTR FAN MTR REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY TERMINALS NOTES -COMPONENT TERMINAL 1). USE COPPER CONDUCTORS ONLY -TERMINAL BLOCK TERMINAL 2). USE 75°C WIRE (OR HIGHER) CONDUCTORS/WIRING 3). OVERCURRENT PROTECTION FOR EVAPORATOR FAN MOTORS AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON EVAPORATOR NAMEPLATE. FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS 4). MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON EVAPORATOR . ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 1-LP AIR 09/06 T30-TPLP-PDI-11 -8- 23/06/17 TPLP PSC 60Hz WIRING DIAGRAM - 460/1/60 STANDARD PSC MOTORS AIR DEFROST MODELS WITHOUT DEFROST TIME CLOCK WITH DEFROST TIME CLOCK 460-1-60 Hz 380/400-1-50Hz L1 DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT GND 3 4 380/400-1-50Hz L2(N) L1 GND TM 1 460-1-60 Hz CONTROL VOLTAGE L2 L1 CONTROL VOLTAGE L2 GND GND FUSE OR CIRCUIT BREAKER NOTE #3 X 2 FUSE OR CIRCUIT BREAKER NOTE #3 OMIT 2ND FUSE IF(N) N L2(N) L1 OMIT 2ND FUSE IF(N) GND M2 M1 M2 M1 TO MULTIPLE EVAPORATORS (IF APPLIC) PUMP DOWN SWITCH (IF USED) TO MULTIPLE EVAPORATORS (IF APPLIC) LIQUID LINE SPACE THERMOSTAT SOLENOID VALVE NOTE #4 NOTE #4 LIQUID LINE SPACE THERMOSTAT SOLENOID VALVE NOTE #4 NOTE #4 N.C. N.C. M1 M2 EVAPORATOR EVAPORATOR 4 TERMINAL BOARD GND. M1 M2 N GND. FAN MOTOR POWER PLUGS FAN MTR FAN MTR FAN MTR REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY N FAN MOTOR POWER PLUGS FAN MTR FAN MTR FAN MTR REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY TERMINALS NOTES -COMPONENT TERMINAL 1). USE COPPER CONDUCTORS ONLY -TERMINAL BLOCK TERMINAL 2). USE 75°C WIRE (OR HIGHER) CONDUCTORS/WIRING 3). OVERCURRENT PROTECTION FOR EVAPORATOR FAN MOTORS AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON EVAPORATOR NAMEPLATE. FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS 4). MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON EVAPORATOR . ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 6-LP 460 AIR 09/06 T30-TPLP-PDI-11 4 TERMINAL BOARD -9- 23/06/17 TPLP PSC WIRING DIAGRAM - 208-230/1/60 60Hz STANDARD PSC MOTORS ELECTRIC DEFROST MODELS - SINGLE EVAPORATOR 10A MAX. FOR ALL MODELS WITHOUT DEFROST HEATER CONTACTOR USING MAXIMUM 15A HEATER OVERCURRENT PROTECTION REFER TO EVAPORATOR NAMEPLATE FOR ELECTRICAL REQUIREMENTS DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT L1 L2 GND TM 3 1 4 FUSE OR CIRCUIT BREAKER X 2 N 15A COMPR INTERLOCK (IF USED) SPACE THERMOSTAT NOTE #4 WARNING EVAP FIELD MODIFICATION MUST BE MADE N.C. SEE NOTE: LIQUID LINE SOL VALVE NOTE #4 PUMP DOWN SWITCH (IF USED) 1 RELOCATE WHITE WIRE FROM 2 INSTALL ORANGE JUMPER N TO H1 AS SHOWN (SUPPLIED LOOSE) FROM H2 TO N 2 ORANGE JUMPER 4 X F BN GND. N H2 H1 3 H3 1 DT C BK RD FD DEFROST TERMINATION & FAN DELAY CONTROL (10.0A MAX.) YL WH HEATER LIMIT SWITCH DT-DEFROST TERM FD-FAN DELAY (10.0A MAX.) DEFROST HEATERS FAN MOTOR POWER PLUGS FAN MTR 1 FAN MTR 2 FAN MTR 6 REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY NOTES EVAPORATOR TERMINALS 1). USE COPPER CONDUCTORS ONLY -COMPONENT TERMINAL 2). USE 75°C WIRE (OR HIGHER) -TERMINAL BLOCK TERMINAL 3). OVERCURRENT PROTECTION FOR EVAPORATOR FAN MOTORS AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON EVAPORATOR NAMEPLATE. CONDUCTORS/WIRING 4.) MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON EVAPORATOR ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS 2-LP ED 12/07 T30-TPLP-PDI-11 - 10 - 23/06/17 TPLP PSC WIRING DIAGRAM - 208-230/1/60 60Hz STANDARD PSC MOTORS ELECTRIC DEFROST MODELS - SINGLE EVAPORATOR FOR ALL MODELS USING DEFROST HEATER CONTACTOR REFER TO EVAPORATOR NAMEPLATE FOR ELECTRICAL REQUIREMENTS DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT L1 L2 GND TM 3 1 4 X 2 FUSE OR CIRCUIT BREAKER NOTE #3 FUSE OR CIRCUIT BREAKER NOTE #3 N L1 L2 COMPR INTERLOCK (IF USED) T1 SPACE THERMOSTAT NOTE #4 LIQUID LINE SOL VALVE NOTE #4 X F N BN RD DT GND. T2 N.C. PUMP DOWN SWITCH (IF USED) 4 DEFROST HEATER CONTACTOR C 3 H2 H1 H3 YL WH C BK FD DEFROST TERMINATION & FAN DELAY CONTROL (10.0A MAX.) DT-DEFROST TERM FD-FAN DELAY HEATER LIMIT SWITCH (10.0A MAX.) DEFROST HEATERS FAN MOTOR POWER PLUGS FAN MTR 1 FAN MTR 2 FAN MTR 6 REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY NOTES EVAPORATOR TERMINALS 1). USE COPPER CONDUCTORS ONLY -COMPONENT TERMINAL 2). USE 75°C WIRE (OR HIGHER) -TERMINAL BLOCK TERMINAL 3). OVERCURRENT PROTECTION FOR EVAPORATOR FAN MOTORS AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON EVAPORATOR NAMEPLATE. CONDUCTORS/WIRING FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS 4.) MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON EVAPORATOR ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 3-LP ED CONTACTOR SINGLE 12/07 T30-TPLP-PDI-11 - 11 - 23/06/17 TPLP PSC WIRING DIAGRAM - 208-230/3/60 60Hz STANDARD PSC MOTORS ELECTRIC DEFROST MODELS - SINGLE EVAPORATOR FOR ALL MODELS USING 3 PHASE DEFROST HEATER CONTACTOR REFER TO EVAPORATOR NAMEPLATE FOR ELECTRICAL REQUIREMENTS DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT L1 L2 L3 GND TM 3 1 4 X 2 FUSE OR CIRCUIT BREAKER NOTE #3 FUSE OR CIRCUIT BREAKER NOTE #3 N L1 L2 L3 T1 T2 T3 C COMPR INTERLOCK (IF USED) SPACE THERMOSTAT NOTE #4 X F N BN RD DT GND. N.C. LIQUID LINE SOL VALVE NOTE #4 PUMP DOWN SWITCH (IF USED) 4 DEFROST HEATER CONTACTOR 3 H2 H1 H3 YL WH C BK FD DEFROST TERMINATION & FAN DELAY CONTROL (10.0A MAX.) DT-DEFROST TERM FD-FAN DELAY HEATER LIMIT SWITCH (10.0A MAX.) DEFROST HEATERS FAN MOTOR POWER PLUGS FAN MTR 1 FAN MTR 2 FAN MTR 6 REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY NOTES TERMINALS 1). USE COPPER CONDUCTORS ONLY -COMPONENT TERMINAL 2). USE 75°C WIRE (OR HIGHER) -TERMINAL BLOCK TERMINAL 3). OVERCURRENT PROTECTION FOR EVAPORATOR FAN MOTORS AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON EVAPORATOR NAMEPLATE. CONDUCTORS/WIRING FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS 4.) MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON EVAPORATOR ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 3A-LP ED 3ph.CONTACTOR SINGLE 12/07 T30-TPLP-PDI-11 EVAPORATOR - 12 - 23/06/17 TPLP PSC WIRING DIAGRAM - 460/1/60 60Hz STANDARD PSC MOTORS ELECTRIC DEFROST MODELS - SINGLE EVAPORATOR FOR ALL 460V MODELS USING DEFROST HEATER AND FAN CONTACTORS REFER TO EVAPORATOR NAMEPLATE FOR ELECTRICAL REQUIREMENTS DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT 1 4 GND GND TM 3 L1 L2 L1 L2(N) FUSE OR CIRCUIT BREAKER NOTE #3 X 2 N FUSE OR CIRCUIT BREAKER NOTE #3 L2 L1 COMPR INTERLOCK (IF USED) L1 L2 T1 T2 C EVAP FAN CONTACTOR M2 N.C. LIQUID LINE SOL VALVE NOTE #4 PUMP DOWN SWITCH (IF USED) M1 T2 T1 SPACE THERMOSTAT NOTE #4 DEFROST HEATER CONTACTOR C H1 H2 4 3 X F N BN DT GND. C RD BK FD DEFROST TERMINATION & FAN DELAY CONTROL (10.0A MAX.) DT-DEFROST TERM FD-FAN DELAY COIL DEFROST HEATERS YL WH HEATER LIMIT SWITCH FAN MOTOR POWER PLUGS FAN MTR FAN MTR FAN MTR NOTES EVAPORATOR TERMINALS 1). USE COPPER CONDUCTORS ONLY -COMPONENT TERMINAL 2). USE 75°C WIRE (OR HIGHER) -TERMINAL BLOCK TERMINAL 3). OVERCURRENT PROTECTION FOR EVAPORATOR FAN MOTORS AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON EVAPORATOR NAMEPLATE. CONDUCTORS/WIRING FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS 4.) MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON EVAPORATOR ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 7-LP ED CONTACTOR SINGLE 12/07 T30-TPLP-PDI-11 REFER TO EVAPORTOR DATA PLATE FOR MOTOR QUANTITY (10.0A MAX.) - 13 - 23/06/17 TPLP WIRING DIAGRAM - 208-230/1/60 PSC 60Hz STANDARD PSC MOTORS ELECTRIC DEFROST MODELS - MULTIPLE EVAPORATORS FOR ALL MODELS USING DEFROST HEATER CONTACTOR REFER TO EVAPORATOR NAMEPLATE FOR ELECTRICAL REQUIREMENTS DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT L1 L2 GND TM 3 1 4 FUSE OR CIRCUIT BREAKER NOTE #3 X 2 N FUSE OR CIRCUIT BREAKER NOTE #3 L1 L2 T1 T2 DEFROST HEATER CONTACTOR C COMPR INTERLOCK (IF USED) WARNING N.C. PUMP DOWN SWITCH (IF USED) 4 X F 3 N BN WH DT GND. SPACE THERMOSTAT NOTE #4 EVAP#2 FIELD MODIFICATION FUSE OR CIRCUIT BREAKER NOTE #3 MUST BE MADE SEE NOTE: LIQUID LINE SOL VALVE NOTE #4 4 H2 H1 3 N X F BN YL 1 DT 2 GND. REMOVE AND INSULATE H1 H2 YL C BK RD WH FD FD DEFROST TERMINATION & FAN DELAY CONTROL (10.0A MAX.) HEATER LIMIT SWITCH DT-DEFROST TERM FD-FAN DELAY 2 AS SHOWN RD DEFROST TERMINATION & FAN DELAY CONTROL (10.0A MAX.) RELOCATE WHITE WIRE FROM N AS SHOWN C BK 1 HEATER LIMIT SWITCH DT-DEFROST TERM FD-FAN DELAY (10.0A MAX.) (10.0A MAX.) DEFROST HEATERS DEFROST HEATERS * Remove & Insulate FAN MOTOR POWER PLUGS FAN MTR FAN MTR FAN MTR REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY PRIMARY EVAPORATOR FAN MOTOR POWER PLUGS FAN MTR FAN MTR FAN MTR REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY SECONDARY EVAPORATOR * Fan delay not used on second evap / use fan contactor if total fan amps exceeds 10A NOTES TERMINALS 1). USE COPPER CONDUCTORS ONLY -COMPONENT TERMINAL 2). USE 75°C WIRE (OR HIGHER) -TERMINAL BLOCK TERMINAL 3). OVERCURRENT PROTECTION FOR EVAPORATOR FAN MOTORS AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON EVAPORATOR NAMEPLATE. CONDUCTORS/WIRING FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS 4.) MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON EVAPORATOR ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 4-LP ED CONTACTOR MULTI 12/07 T30-TPLP-PDI-11 - 14 - 23/06/17 TPLP WIRING DIAGRAM - 460/1/60 PSC 60Hz STANDARD PSC MOTORS ELECTRIC DEFROST MODELS - MULTIPLE EVAPORATORS FOR ALL 460V MODELS USING DEFROST HEATER AND FAN CONTACTORS REFER TO EVAPORATOR NAMEPLATE FOR ELECTRICAL REQUIREMENTS DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT 3 4 1 L1 L2 L1 L2(N) GND GND TM FUSE OR CIRCUIT BREAKER NOTE #3 X 2 N FUSE OR CIRCUIT BREAKER NOTE #3 DEFROST HEATER L1 L2 T1 T2 EVAP FAN CONTACTOR SPACE THERMOSTAT NOTE #4 L2 T1 T2 CONTACTOR C COMPR INTERLOCK (IF USED) C L1 FUSE OR CIRCUIT BREAKER NOTE #3 N.C. LIQUID LINE SOL VALVE NOTE #4 PUMP DOWN SWITCH (IF USED) WARNING EVAP#2 FIELD MODIFICATION MUST BE MADE RELOCATE WHITE WIRE FROM 1 N AS SHOWN * M1 M2 H1 H2 4 3 F M1 N X M2 H1 H2 4 F 3 DT GND. GND. C RD BK DEFROST TERMINATION & FAN DELAY CONTROL (10.0A MAX.) DEFROST TERMINATION & FAN DELAY CONTROL (10.0A MAX.) DT-DEFROST TERM FD-FAN DELAY YL DT-DEFROST TERM FD-FAN DELAY DEFROST HEATERS WH YL HEATER LIMIT SWITCH FAN MOTOR POWER PLUGS FAN MTR FAN MTR FAN MTR REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY 1 FD FD DEFROST HEATERS DT C RD BK N X BN BN WH HEATER LIMIT SWITCH (10.0A MAX.) PRIMARY EVAPORATOR FAN MOTOR POWER PLUGS FAN MTR FAN MTR FAN MTR REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY (10.0A MAX.) SECONDARY EVAPORATOR * Note: Fan Delay not used on second evap NOTES TERMINALS 1). USE COPPER CONDUCTORS ONLY -COMPONENT TERMINAL 2). USE 75°C WIRE (OR HIGHER) -TERMINAL BLOCK TERMINAL 3). OVERCURRENT PROTECTION FOR EVAPORATOR FAN MOTORS AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON EVAPORATOR NAMEPLATE. CONDUCTORS/WIRING FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS 4.) MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON EVAPORATOR ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 8-LP 460v ED CONTACTOR MULTI 09/06 T30-TPLP-PDI-11 - 15 - 23/06/17 NO COMPLEX CONTROLS, NO COST ADDER, SIMPLE TO UNDERSTAND TPLP ECM PATENT 60Hz PENDING DESIGN FEATURES US Patents Nos. 8,635,883 & 9,151,525 • Standard on all EC Motors • NO special controls required. • Refrigeration mode – EC motor operates at full speed. Consumption 60 W per motor • Off Cycle mode – EC motor operates at reduced speed. Consumption 13 W per motor. • Energy saving benefit on motor and compressor wattage consumption: 20000 ENERGY CONSUMPTION COMPARISON: with PSC vs ECM vs SmartSpeed Evaporator Fan Motors Energy Consumption (Watt-Hours) 18000 Compressor w/ PSC 16000 Compressor w/ ECM 14000 Compressor w/ SmartSpeed 12000 10000 ADDITIONAL ENERGY SAVINGS WHEN USING SMARTSPEED EVAPS 8000 6000 4000 EVAP w/ PSC 2000 EVAP w/ ECM EVAP with SmartSpeed 0 0 50 100 150 200 250 300 350 400 450 500 Time (minutes) Note: Data collected on a typical freezer application with a 3HP low temp condensing unit and a 4 fan TPLP evaporator INSTALLATION NOTES EC motors are factory wired for SmartSpeed operation on evaporators equipped with a factory installed thermostat. For SmartSpeed operation on Evaporators without a factory installed thermostat, a field wired SPDT type thermostat is required. T30-TPLP-PDI-11 - 16 - 23/06/17 TPLP T30-TPLP-PDI-11 WIRING DIAGRAM - 115/1/60, 208-230/1/60 OPTIONAL EC MOTORS with AIR DEFROST MODELS - 17 - ECM 60Hz 23/06/17 TPLP T30-TPLP-PDI-11 WIRING DIAGRAM - 208-230/1/60 OPTIONAL EC MOTORS with ELECTRIC DEFROST MODELS - 18 - ECM 60Hz 23/06/17 TPLP WIRING DIAGRAM - 208-230/1/60 ECM 60Hz OPTIONAL EC MOTORS with ELECTRIC DEFROST MODELS - MULTIPLE EVAPORATORS T30-TPLP-PDI-11 - 19 - 23/06/17 TPLP 60Hz SHIPPING WEIGHTS Air Defrost Models Electric Defrost Models MODEL TPLP SHIPPING WEIGHT LB. (kg) LB. (kg) 104MA 45 (20) 104ME 104LE 103VE 49 (22) 106MA 47 (21) 106ME 105LE 104VE 51 (23) 107MA 49 (22) 107ME 106LE 105VE 53 (24) 209MA 70 (32) 209ME 207LE 206VE 76 (34) 211MA 74 (33) 211ME 209LE 208VE 80 (36) 214MA 78 (35) 214ME 211LE 209VE 84 (38) 317MA 101 (46) 317ME 314LE 312VE 109 (49) 320MA 107 (48) 320ME 317LE 315VE 115 (52) 423MA 117 (53) 423ME 419LE 416VE 127 (58) 426MA 135 (61) 426ME 422LE 419VE 145 (66) 532MA 163 (74) 532ME 527LE 523VE 176 (80) 639MA 192 (87) 639ME 631LE 627VE 207 (94) T30-TPLP-PDI-11 SHIPPING WEIGHT MODEL TPLP - 20 - 23/06/17 TPLP 60Hz DIMENSIONAL DATA .438 SLOTS IN MOUNTING BRACKETS A B 6 1/2 [165] 3 [76] 1 3/8 [35] 3/4 MPT / 3/4 FLARE DRAIN CONNECTION 11 7/8 [302] 12 [305] MINIMUM 4 [102] TYP ELECTRICAL CONNECTIONS. 13 7/16 [341] MTG SLOTS REFRIGERATION CONNECTIONS. SUCTION & LIQUID. AIR THROW APPROX 35' IN OPEN SPACE 15 7/8 [403] 6 1/2 [165] 1, 2 AND 3 FAN MODELS. (TOP VIEW) 3 1/8 [79] A C B 13 7/16 [341] MTG SLOTS 6 1/2 [165] MODEL TPLP 4, 5 AND 6 FAN MODELS. (TOP VIEW) NO. OF FANS IN (mm) IN (mm) IN (mm) SUCTION CONNECTION (ID) SWEAT A B C LIQUID CONNECTION (ID) SWEAT R407A R22 R404A 104M^ 106M^ 107M^ 209M^ 211M^ 214M^ 317M^ 320M^ 423M^ 426M^ 532M^ 639M^ 1 1 1 2 2 2 3 3 4 4 5 6 30 1/4 30 1/4 30 1/4 46 1/4 46 1/4 46 1/4 62 1/4 62 1/4 78 1/4 78 1/4 94 1/4 110 1/4 (768) (768) (768) (1175) (1175) (1175) (1581) (1581) (1988) (1988) (2394) (2800) 17 1/4 17 1/4 17 1/4 33 1/4 33 1/4 33 1/4 49 1/4 49 1/4 32 5/8 32 5/8 32 5/8 48 5/8 (438) (438) (438) (845) (845) (845) (1251) (1251) (829) (829) (829) (1235) N/A N/A N/A N/A N/A N/A N/A N/A 32 5/8 32 5/8 48 5/8 48 5/8 N/A N/A N/A N/A N/A N/A N/A N/A (829) (829) (1235) (1235) 5/8 5/8 5/8 7/8 7/8 7/8 7/8 7/8 1 1/8 1 1/8 1 3/8 1 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 1/2 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 1/2 1/2 104L^ 105L^ 106L^ 207L^ 209L^ 211L^ 314L^ 317L^ 419L^ 422L^ 527L^ 631L^ 1 1 1 2 2 2 3 3 4 4 5 6 30 1/4 30 1/4 30 1/4 46 1/4 46 1/4 46 1/4 62 1/4 62 1/4 78 1/4 78 1/4 94 1/4 110 1/4 (768) (768) (768) (1175) (1175) (1175) (1581) (1581) (1988) (1988) (2394) (2800) 17 1/4 17 1/4 17 1/4 33 1/4 33 1/4 33 1/4 49 1/4 49 1/4 32 5/8 32 5/8 32 5/8 48 5/8 (438) (438) (438) (845) (845) (845) (1251) (1251) (829) (829) (829) (1235) N/A N/A N/A N/A N/A N/A N/A N/A 32 5/8 32 5/8 48 5/8 48 5/8 N/A N/A N/A N/A N/A N/A N/A N/A (829) (829) (1235) (1235) 5/8 5/8 5/8 7/8 7/8 7/8 7/8 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 1/2 17 1/4 17 1/4 17 1/4 33 1/4 33 1/4 33 1/4 49 1/4 49 1/4 32 5/8 32 5/8 32 5/8 48 5/8 (438) (438) (438) (845) (845) (845) (1251) (1251) (829) (829) (829) (1235) N/A N/A N/A N/A N/A N/A N/A N/A 32 5/8 32 5/8 48 5/8 48 5/8 N/A N/A N/A N/A N/A N/A N/A N/A (829) (829) (1235) (1235) 5/8 5/8 5/8 7/8 7/8 7/8 7/8 1 1/8 1 1/8 1 1/8 1 3/8 1 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 1/2 103V^ 104V^ 105V^ 206V^ 208V^ 209V^ 312V^ 315V^ 416V^ 419V^ 523V^ 627V^ ^ = A or E. 1 30 1/4 (768) 1 30 1/4 (768) 1 30 1/4 (768) 2 46 1/4 (1175) 2 46 1/4 (1175) 2 46 1/4 (1175) 3 62 1/4 (1581) 3 62 1/4 (1581) 4 78 1/4 (1988) 4 78 1/4 (1988) 5 94 1/4 (2394) 6 110 1/4 (2800) Refer to Nomenclature for details T30-TPLP-PDI-11 - 21 - 23/06/17 TPLP SPORLAN MODEL TPLP 60Hz RECOMMENDED EXPANSION VALVE SELECTIONS - MEDIUM TEMP. MODELS FACTORY INSTALLED NOZZLE ALCO R404A R507 R448A R407A R407C R22 R134a MODEL TPLP FACTORY INSTALLED NOZZLE R448A R407A R407C R22 R404A R507 R134a 104M N/A EBQE-AA-*C EBQE-AAA-VC EBQE-AAA-JC 104M N/A HFESC 1/4 SC HFESC 1/2 HC HFESC 1/2 MC 106M L-1/2 EBQE-AA-*C EBQE-AA-VC EBQE-AA-JC 106M L-1/2 HFESC 1/2 SC HFESC 1/2 HC HFESC 3/4 MC 107M L-1/2 EBQE-A-*C EBQE-AA-VC EBQE-AA-JC 107M L-1/2 HFESC 1/2 SC HFESC 1/2 HC HFESC 3/4 MC 209M L-3/4 EBQE-A-*C EBQE-AA-VC EBQE-AA-JC 209M L-3/4 HFESC 1 SC HFESC 1 HC HFESC 3/4 MC HFESC 1 MC 211M L-1 EBQE-A-*C EBQE-A-VC EBQE-A-JC 211M L-1 HFESC 1 SC HFESC 1 HC 214M L-1 EBQE-B-*C EBQE-A-VC EBQE-A-JC 214M L-1 HFESC 1-1/4 SC HFESC 1-1/2 HC HFESC 1 MC 317M L-1 1/2 EBQE-B-*C EBQE-A-VC EBQE-A-JC 317M L-1 1/2 HFESC 1-1/2 SC HFESC 1-1/2 HC HFESC 1-1/2 MC 320M L-1 1/2 EBQE-B-*C EBQE-B-VC EBQE-A-JC 320M L-1 1/2 HFESC 1-1/2 SC HFESC 2 HC HFESC 1-3/4 MC 423M L-2 EBQE-B-*C EBQE-B-VC EBQE-A-JC 423M L-2 HFESC 2 SC HFESC 2 HC HFESC 1-3/4 MC 426M L-2 EBQE-C-*C EBQE-B-VC EBQE-B-JC 426M L-2 HFESC 2 SC HFESC 2-1/2 HC HFESC 2-1/2 MC 532M L-2 1/2 EBQE-C-*C EBQE-B-VC EBQE-B-JC 532M L-2 1/2 HFESC 3-1/2 SC HFESC 2-1/2 HC HFESC 2-1/2 MC 639M G-3 EBQE-C-*C EBQE-C-VC EBQE-C-JC 639M G-3 HFESC 3-1/2 SC HFESC 3 HC HFESC 4 MC * Varies with refrigerant: S = R404A, P = R507 For R449A, use R448A data. For R449A, use R448A data. DANFOSS MODEL TPLP FACTORY INSTALLED NOZZLE R404A R507 R448A R407A R407C † R22 R134a 104M N/A TUAE-R404A-4-N TUAE-R22-4-N TUAE-R134a-4-N 106M L-1/2 TUAE-R404A-5-N TUAE-R22-5-N TUAE-R134a-5-N 107M L-1/2 TUAE-R404A-6-N TUAE-R22-5-N TUAE-R134a-5-N 209M L-3/4 TUAE-R404A-7-N TUAE-R22-6-N TUAE-R134a-6-N 211M L-1 TUAE-R404A-7-N TUAE-R22-6-N TUAE-R134a-6-N 214M L-1 TUAE-R404A-8-N TUAE-R22-7-N TUAE-R134a-7-N 317M L-1 1/2 TUAE-R404A-8-N TUAE-R22-8-N TUAE-R134a-8-N 320M L-1 1/2 TUAE-R404A-9-N TUAE-R22-8-N TUAE-R134a-8-N 423M L-2 TUAE-R404A-9-N TUAE-R22-8-N TUAE-R134a-9-N 426M L-2 TCAE-R404A-TC1-N TUAE-R22-9-N TUAE-R134a-9-N 532M L-2 1/2 TCAE-R404A-TC2-N TUAE-R22-9-N TCAE-R134a-TC1-N 639M G-3 TCAE-R404A-TC3-N TCAE-R22-TC1-N TCAE-R134a-TC2-N † If using 407C, superheat setting must be adjusted by turning 1 - 1.5 turns clockwise. For R449A, use R448A data. Above selections based on: 1) 100°F (38°C) vapor free liquid entering expansion valve 2) 110°F (43°C) Condensing temperature 3) 8 -12°F (4.4 -6.7°C) evaporator TD T30-TPLP-PDI-11 - 22 - If correct nozzle is not available, the proper orifice size can be drilled in the field using the following chart NOZZLE ORIFICE No. DRILL SIZE 1/2 .070 3/4 .086 1 .0995 IN. 1-1/2 .120 2 .1406 2-1/2 .157 3 .172 4 .199 5 .211 6 .242 8 .266 10 .281 23/06/17 TPLP RECOMMENDED EXPANSION VALVE SELECTIONS - LOW TEMP. MODELS 60Hz SPORLAN - R407A R448A MODEL TPLP 104L FACTORY INSTALLED NOZZLE L-1/2 0° F (-18° C) EVAP. -10° F (-23° C) EVAP. -20° F (-29° C) EVAP. -30° F (-34° C) EVAP. EBQE-AAA-VC EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 105L L-3/4 EBQE-AA-VC EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 106L L-1 EBQE-AA-VC EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 207L L-1 EBQE-AA-VC EBQE-AA-VZP40 EBQE-A-VZP40 EBQE-A-VZP40 EBQE-A-VZP40 209L L-1-1/2 EBQE-AA-VC EBQE-A-VZP40 EBQE-A-VZP40 EBQE-A-VZP40 EBQE-A-VZP40 -40° F (-40° C) EVAP. 211L L-2 EBQE-A-VC EBQE-A-VZP40 EBQE-A-VZP40 EBQE-A-VZP40 EBQE-B-VZP40 314L L-2 EBQE-A-VC EBQE-A-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 317L L-3 EBQE-A-VC EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 419L L-3 EBQE-A-VC EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 422L G-4 EBQE-B-VC EBQE-B-VZP40 EBQE-B-VZP40 EBQE-C-VZP40 EBQE-C-VZP40 527L G-4 EBQE-B-VC EBQE-C-VZP40 EBQE-C-VZP40 EBQE-C-VZP40 EBQE-C-VZP40 631L G-5 EBQE-C-VC EBQE-C-VZP40 EBQE-C-VZP40 EBQE-C-VZP40 EBQE-C-VZP40 103V L-1/2 EBQE-AAA-VC EBQE-AAA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 104V L-3/4 EBQE-AAA-VC EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 105V L-1 EBQE-AA-VC EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 206V L-1 EBQE-AA-VC EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-AA-VZP40 EBQE-A-VZP40 208V L-1 1/2 EBQE-AA-VC EBQE-AA-VZP40 EBQE-A-VZP40 EBQE-A-VZP40 EBQE-A-VZP40 209V L-2 EBQE-A-VC EBQE-A-VZP40 EBQE-A-VZP40 EBQE-A-VZP40 EBQE-A-VZP40 312V L-2 EBQE-A-VC EBQE-A-VZP40 EBQE-A-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 315V L-2 1/2 EBQE-A-VC EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 416V L-2 1/2 EBQE-A-VC EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 419V G-3 EBQE-A-VC EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 EBQE-B-VZP40 523V G-4 EBQE-B-VC EBQE-B-VZP40 EBQE-C-VZP40 EBQE-C-VZP40 EBQE-C-VZP40 627V G-5 EBQE-B-VC EBQE-C-VZP40 EBQE-C-VZP40 EBQE-C-VZP40 EBQE-C-VZP40 For R449A, use R448A data. SPORLAN - R404A MODEL TPLP 104L FACTORY INSTALLED NOZZLE L-1/2 0° F (-18° C) EVAP. EBQE-AA-SC EBQE-AA-SZP EBQE-AA-SZP EBQE-AA-SZP EBQE-AA-SZP 105L L-3/4 EBQE-AA-SC EBQE-AA-SZP EBQE-AA-SZP EBQE-AA-SZP EBQE-AA-SZP -10° F (-23° C) EVAP. -20° F (-29° C) EVAP. -30° F (-34° C) EVAP. -40° F (-40° C) EVAP. 106L L-1 EBQE-AA-SC EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP 207L L-1 EBQE-A-SC EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP 209L 1-1/2 EBQE-A-SC EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP 211L L-2 EBQE-A-SC EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP 314L L-2 EBQE-B-SC EBQE-B-SZP EBQE-B-SZP EBQE-B-SZP EBQE-B-SZP 317L L-3 EBQE-B-SC EBQE-B-SZP EBQE-B-SZP EBQE-B-SZP EBQE-B-SZP 419L L-3 EBQE-B-SC EBQE-B-SZP EBQE-C-SZP EBQE-C-SZP EBQE-C-SZP 422L G-4 EBQE-C-SC EBQE-C-SZP EBQE-C-SZP EBQE-C-SZP EBQE-C-SZP 527L G-4 EBQE-C-SC EBQE-C-SZP EBQE-C-SZP EBSE-6-SZP EBSE-6-SZP 631L G-5 EBSE-6-SC EBSE-6-SZP EBSE-6-SZP EBSE-6-SZP EBSE-6-SZP 103V L-1/2 EBQE-AA-SC EBQE-AA-SZP EBQE-AA-SZP EBQE-AA-SZP EBQE-AA-SZP 104V L-3/4 EBQE-AA-SC EBQE-AA-SZP EBQE-AA-SZP EBQE-AA-SZP EBQE-AA-SZP EBQE-AA-SZP 105V L-1 EBQE-AA-SC EBQE-AA-SZP EBQE-AA-SZP EBQE-AA-SZP 206V L-1 EBQE-A-SC EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP 208V L-1 1/2 EBQE-A-SC EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP 209V L-2 EBQE-A-SC EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP EBQE-A-SZP 312V L-2 EBQE-A-SC EBQE-A-SZP EBQE-A-SZP EBQE-B-SZP EBQE-B-SZP 315V L-2 1/2 EBQE-B-SC EBQE-B-SZP EBQE-B-SZP EBQE-B-SZP EBQE-B-SZP 416V L-2 1/2 EBQE-B-SC EBQE-B-SZP EBQE-B-SZP EBQE-B-SZP EBQE-B-SZP 419V G-3 EBQE-B-SC EBQE-B-SZP EBQE-C-SZP EBQE-C-SZP EBQE-C-SZP 523V G-4 EBQE-C-SC EBQE-C-SZP EBQE-C-SZP EBQE-C-SZP EBQE-C-SZP 627V G-5 EBQE-C-SC EBQE-C-SZP EBQE-C-SZP EBSE-6-SZP EBSE-6-SZP Above selections based on: 1) 100°F (38°C) vapor free liquid entering expansion valve 2) 110°F (43°C) Condensing temperature 3) 8 -12°F (4.4 -6.7°C) evaporator TD T30-TPLP-PDI-11 - 23 - 23/06/17 TPLP INSTALLATION INSTRUCTIONS 60Hz INSTALLATION EXPANSION VALVE (TXV) PRE-SELECTED The installation and start-up of evaporators should only be performed by qualified refrigeration mechanics. This equipment should be installed in accordance with all applicable codes, ordinances and local by-laws. Locate the expansion valve bulb on a horizontal length of suction line preferably 3 to 6 inches from the suction header. Locate the bulb at 4 or 8 clock position and insulate with a waterproof type of insulation. Clamp the bulb to ensure 100% contact of the bulb with the suction line. INSPECTION Inspect all equipment before unpacking for visible signs of damage or loss. Check shipping list against material received to ensure shipment is complete. After following the manufacturer’s installation instructions and after the room has reached the desired temperature the valve superheat should be checked. This will confirm that the evaporator is operating properly and performing to maximum efficiency. The superheat should be around 6 (3.3°C) to 8°F (4.4°C) for a 10 to 12°F T.D (5.6 to 6.7°C). Too high or low a super heat will result in unsatisfactory system performance and possible compressor problems. IMPORTANT: Remember, you, the consignee, must make any claim necessary against the transportation company. Shipping damage or missing parts, when discovered at the outset, will prevent later unnecessary and costly delays. If damage or loss during transport is evident, make claim to carrier, as this will be their responsibility, not the manufacturer’s. Should carton be damaged, but damage to equipment is not obvious, a claim should be filed for “concealed damage” with the carrier. MOUNTING Refer to dimensional drawing for recommended mounting arrangements. Ensure adequate clearance is provided behind the coil as well as each end. The evaporators may be mounted flush with ceiling with bolts, or hanging down with rod hangers. When using rod hangers, allow adequate space between the top of the unit and the ceiling for cleaning to comply with NSF Standard 7. Ensure that the ceiling is level since the drain pan has been sloped for drainage during the defrost cycle. IMPORTANT: The electrical characteristics of the unit should be checked at this time to make sure they correspond to those ordered and to electrical power available at the job site. Save all shipping papers, tags and instruction sheets for reference by installer and owner. APPLICATION TPLP evaporators are designed for walker-in cooler and freezer applications used with a wide range of refrigerants. For room temperatures above 35°F (2°C) AND evaporating temperatures above 26°F (-3°C), positive defrosting means (electric) may not be required, otherwise, electric defrost defrost models should be used. Electric defrost models come with defrost termination and fan delay as standard to control the defrost cycle termination and fan delay, while defrost initiation means (e.g. defrost timer) is not included. DRAIN LINE The drain line should be run from the drain connection, sloping at least 1” (25 mm) per foot and should have the size at least as large as the drain connection. A P-Trap in a warm area outside the room must be provided to allow proper draining through the tubing. Connection should be made to proper drainage facilities that comply with local regulations. To prevent freeze-up when the temperature of the refrigerated space is 35°F (2°C) or lower, the drain line should be heated along its run inside the cold room. The heated drain line should be insulated. It is recommended that the heater be energized at all times. A heat input of 20 watts per foot in a 28°F (-2°C) room and 30 watts per foot for -20°F (-29°C) rooms, is satisfactory. Drain line heaters are not required for constant room temperature above 35°F (2°C). Always trap evaporator drain line individually to prevent vapor migration. The coil must not be exposed to any abnormal atmospheric or acidic environments. This may result in corrosion to the cabinet and possible coil failure (leaks). (Consult manufacturer for optional baked on phenolic protective coatings). LOCATION The unit location in the room should be selected to ensure uniform air distribution throughout the entire space to be refrigerated. Be sure that the product does not obstruct the free circulation of air. Allow a minimum of 24” clearance at each end. Do not locate evaporators over doors. Consideration should be given to the coil location in order to minimize the piping run length to the condensing unit and floor drain. T30-TPLP-PDI-11 Ensure that the drain line has sufficient slope for proper drainage (prevention of ice build up/blockage in pan). - 24 - 23/06/17 TPLP INSTALLATION INSTRUCTIONS PIPING Refrigeration grade piping must be used for all field refrigeration piping. Refrigerant line sizes are important and may not be the same size as the coil connections. Consult ASHRAE handbook or other similar reference book for proper line sizing. Refrigerant piping and control system should be designed to prevent possible liquid slugging (from oil or refrigerant) of the compressors on start-up after the defrost cycle. Also, it should prevent oil logging and minimize refrigerant pressure drop. WIRING Wire system in accordance with governing standards and local codes. See data and wiring diagrams on pages 4 to 20 for typical wiring arrangement. Electrical wiring is to be sized in accordance with minimum circuit ampacity rating (MCA). Size fuses used must not exceed the Maximum Fuse Size ratings. For ease of identifying the proper wiring terminal, unit wiring is color coded and terminal block connections are identified. When fan delay thermostats (combination fan delay and defrost termination) are installed, on start-up, the fans do not operate until the coil temperature is reduced to approximately 25oF (-4°C). It is normal for the fans to cycle a few times until the room temperature is brought down. At higher evaporating temperatures this control may not close and therefore should either be by-passed temporarily or replaced with an adjustable type. (set for a higher temperature cut-in point). MAINTENANCE The unit should be periodically inspected for any dirt or ice build-up on the fin surface and cleaned if necessary with a soft whisk or brush. Also ensure coils inner (and outer) drain pans do not have any ice build-up from improper defrost operation. When replacing heater elements first remove heater retainer brackets and heater clips. T30-TPLP-PDI-11 - 25 - 60Hz SYSTEM CHECK Before Start-Up: 1. All wiring should be in accordance with local codes. 2. Refrigerant lines should be properly sized. 3. Thorough evacuation and dehydration has been performed. 4. The suction, discharge, and receiver service valves must be open. 5. The system preferably include a liquid line filter drier moisture indicator and suction filter. 6. Pour enough water into the drain pan to allow a good check on drainage and seal the trap. After Start-Up: 1.Check the oil level to be sure the oil charge is correct. 2. On initial start up the fans do not start until coil temperature is pulled down to approximately 25°F (-4°C) on the coil. Also, it is normal for the fan to cycle a few times until the room temperature is pulled down. 3. If necessary, temporarily by-pass fan delay control (to run fans until room temp is lowered). 4. Be sure that the expansion valve is properly set to provide the correct amount of superheat. 5. After the box temperature is close to reaching the desired temperature, the evaporator superheat must be checked and adjustment made if necessary. In general, evaporators running with a TD of 10°F (5.6°C ) should have a superheat reading of 6° to 8°F (3.3°C to 4.4°C). For evaporators with another T.D., the general rule is that the superheat should be around 60 to 80% of T.D. 6. Heavy moisture loads are usually encountered when starting the system for the first time. This may cause a rapid build-up of frost on the evaporator. During the initial pull down, we suggest that the frost build-up be watched and defrosted manually as required. 7. Observe that the system goes through at least one complete DEFROST CYCLE. 23/06/17 TPLP PROJECT INFORMATION 60Hz System Model Number Date of Start-Up Serial Number Service Contractor Refrigerant Phone Electrical Supply E-Mail T30-TPLP-PDI-11 - 26 - 23/06/17 TPLP PRODUCT SUPPORT RESOURCES 60Hz web: t-rp.com/tplp email: [email protected] call: 1-844-893-3222 x520 email: [email protected] call: 1-844-893-3222 x529 web: t-rp.com/serv_parts.htm email: [email protected] call: 1-844-893-3222 x501 web: t-rp.com/warranty email: [email protected] call: 1-844-893-3222 ext. 501 email: [email protected] call: 1-844-893-3222 x501 email: [email protected] call: 1-844-893-3222 x503 T30-TPLP-PDI-11 - 27 - 23/06/17 “AS BUILT” SERVICE PARTS LIST Service Parts List Label To Be Attached HERE NATIONAL REFRIGERATION & AIR CONDITIONING CANADA CORP. 159 Roy Blvd. Brantford Ontario Canada N3R 7K1 PHONE: (519) 751-0444 800-463-9517 FAX (519) 753-1140 www.t-rp.com Due to National Refrigeration’s policy of continuous product improvement, we reserve the right to make changes without notice. 23/06/17
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement