Agilent E4982A LCR Meter 1 MHz to 3 GHz

Add to My manuals
16 Pages

advertisement

Agilent E4982A LCR Meter 1 MHz to 3 GHz | Manualzz

Agilent

E4982A LCR Meter

1 MHz to 3 GHz

New Standard for High-Speed Component Tests

New Standard for High-Speed Component Tests

The Agilent E4982A LCR meter provides the best performance for the passive component manufacturing such as SMD inductors and EMI filters, where impedance testing at high frequencies is required. Not only for the manufacturing, E4982A can also be utilized for

R&D, quality assurance with the powerful functions such as list measurements. By offering the unparalleled measurement speed and repeatability with excellent accuracy and impedance range, E4982A is the new standard for high-speed component tests.

• Test head with 3.5 mm (female) connector

• Extension to an automated component handler without introducing additional errors

• 2 m (option 020) is available

Small test head with 1 m test cable

Key Features

Unparalleled measurement speed

& repeatability

• 0.9 ms/point (measurement time mode 1)

• 2.1 ms/point (measurment time mode 2)

• 3.7 ms/point (measurement time mode 3)

• Low variation for repeatability

Excellent accuracy & impedance range

• Basic accuracy: ± 0.8%

• Impedance range: 140 mΩ to 4.8 kΩ

Compatible to 4287A LCR meter

• SCPI commands

• Handler interface

• Test head size

1

• 7 mm test fixtures

1. The test head of 4287A cannot be used with the E4982A

Powerful functions

• Calibration/compensation with Wizard

• Rdc measurement for contact check

• Multi-function comparator & handler I/F

• Statistical analysis functions

• List measurement function

• User defined function keys/parameters

• Context sensitive embedded help

Modern U/I & connectivity

• 10.4 inch LCD touch screen

• GPIB/LAN/USB control interfaces

• Windows OS

Compact body

• 277 mm depth

Wide variety of accessories

• Various sizes for SMD

• External DC bias adapter

2

Modern User Interface & Connectivity in Compact Body

The Agilent E4982A LCR meter is developed on the latest platform, which provides the modern user interface and connectivity in compact body.

• Easy to use with 10.4 inch LCD touch screen and navigation keys in addition to keyboard and mouse

• PC connectivity via GPIB/LAN/USB control interfaces

• Windows OS

• Compact body (277 mm depth)

Compact Body

(Comparison with 4287A)

E4982A

277 mm

445 mm

4287A

Rdc (DC resistance) measurement function

For contact check

Front panel

Signal-level monitor function

Monitors the test signal voltage or current applied to DUT

10.4 inch LCD touch screen

Selectable measurement parameters

(4 parameters can be displayed)

Navigation keys and rotary knob

Supports front panel operation without the mouse

Context sensitive embedded help

USB

Rear panel

USB (USBTMC)

GPIB interface

Handler interface

External trigger IN

Peripheral ports

(USB, LAN, XGA output)

3

Unparalleled Measurement Speed & Repeatability

Faster measurement speed

The E4982A allows you to make much faster measurements compared to 4287A, which is widely used as the industry standard. This drastically helps improving the manufacturing throughput.

1.6 ms/point with mode 1 (< 20.3 MHz)

0.9 ms/point with mode 1 (≥ 20.3 MHz)

2.1 ms/point with mode 2

3.7 ms/point with mode 3

(Index signal)

E4982A

Mode1

E4982A

Mode2

E4982A

Mode3

4287A

0 2 4

Measurement Time [ms]

6

Measurement speed comparison

8

Lower measurement variation for better repeatability

The advanced techniques in the E4982A analog-circuit also provides even lower measurement variation than

4287A. By taking the lower measurement variation into consideration along with the measurement speed, the practical measurement speed at the equivalent measurement variation versus 4287A can drastically improve the measurement speed. This means that even smaller inductance can be measured while maximizing the manufacturing throughput.

E4982A

Mode1

E4982A

Mode2

E4982A

Mode3

4287A

0

Ls Q

E4982A

Mode1

E4982A

Mode2

E4982A

Mode3

4287A

0.001 0.002 0.003 0.004 0.005 0.006 0.007 0.008

[nH]

0 0.02 0.04

0.06 0.08

0.1

0.12 0.14

0.16

[nH]

Measurement variation comparison (supplemental information)

DUT: 10 nH (Q = 15)

Conditions: 100 MHz, 0.5 V, AVG 1,

3 Sigma with 100 times measurements

4

Excellent Accuracy & Impedance Range

More accurate measurements over wider impedance range

The E4982A employs the RF-IV measurement method that measures voltage and current at device under test

(DUT). The E4982A enables more accurate measurement over wide impedance range than that of network analyzer and also even 4287A, for a very small inductance on the order of a few nH, as an advantage.

4287A

E4982A

Example of meas. accuracy

Zx = 50 Ω (at 100 MHz)

1

Example of meas. accuracy

Zx = 6.28 Ω (10 nH)

2

Impedance measurement range

(meas. accuracy ≤ ± 10%)

3

Mode 1

± 0.85 %

± 1.58 %

0.16 Ω ~

4.3 kΩ

1. Ave = 8, OSC = 1 dBm, calibration is performed (at 23 ± 5 °C)

2. Freq = 100 MHz, Ave = 8, OSC = 1 dBm, calibration is performed (at 23 ± 5 °C)

3. Freq = 1 MHz, Ave = 8, OSC = 1 dBm, calibration is performed (at 23 ± 5 °C)

Mode 2

± 0.82 %

± 1.55 %

0.14 Ω ~

4.7 kΩ

Mode 3

± 0.80 %

± 1.52 %

0.14 Ω ~

4.8 kΩ

± 1.02 %

± 1.79 %

0.20 Ω ~

3.0 kΩ

10000

1000

100

10

1

0.1

1 10 100

[MHz]

1000

Examples of calculated impedance measurement accuracy

Meas. speed mode 3, osc. level 1 dBm, AVG ≥ 8, temp (at 23 ± 5 °C)

5

0.8%

1%

2%

5%

10%

Maximizing Throughput & Quality in Manufacturing

Accurate automated testing by calibaration with different reference values

It is very important to eliminate complicated error elements caused by the use of test fixtures and cables that extend the test head of the E4982A. This is especially true for measurements that use an automated component handler. Accurate measurements, which correlate well with results obtained from manual testing, can be achieved at the measurement plane of a test fixture by performing open/short/load calibration with a “working” load standard.

Since different calibration standard reference values can be independently set at each list measurement frequency, multi-frequency measurements can be made accurately with this reliable calibration function.

Calibration standard data setup display

Different calibration reference values can independently be set at each list measurement frequency

Contact check using the Rdc measurement function

Contact failure between a DUT and the measurement plane of an automatic component handler is a factor for bin sorting error in production line testing. Contact check using the built-in DC resistance measurement function improves the accuracy and efficiency of bin sorting.

Rdc measurement

6

Interfacing with an automated component handler

The measurement plane can be extended from the front panel of the instrument to the measurement stage with the 1 m test cable and the small size test head. It is possible to extend the test cable an additional meter with a 1 m extension cable (option 020).

Note that the measurement accuracy is specified at the test head. In addition, connection to an external computer or an automated component handler can be accomplished via the GPIB/LAN/USB interface and the opto-isolated handler interface. The LAN interface enables network communication, and greatly empowers massive data transfer to a remote computer.

GPIB/LAN/

USB interface

PC

Handler interface

Handler

Multi-function comparator

The comparator setup display is formatted as a table. Each row represents a bin number, and each column represents the sorting conditions for each bin. When all sorting conditions set for a bin are satisfied, the judgment result is sorted to the bin. There are thirteen bins, with four limit values for each bin. Conditions such as frequency and measurement parameters can be set independently in each column, enabling the E4982A to meet various sorting needs, including different parameters at different measurement frequencies.

Bin-sort sequence

7

Comparator setup display

Statistical analysis functions

The E4982A is equipped with functions to statistically analyze data. These functions improve the efficiency of the data acquisition required in quality control.

The statistical analysis function calculates the following statistical parameters for as many as

1,000,000,000 measurement points. Original measurement results for the statistical analysis function can be obtained via GPIB/LAN/USB interface.

• mean, maximum, minimum, standard deviation,

3σ/mean

Statistical analysis

Data storage and transfer

The E4982A built-in data storage includes a hard disk drive and USB ports. These powerful storage devices permit to save and recall your measurement setup parameters (instrument state) and measurement data. In addition, measurement setup parameters and data can be transferred between the E4982A and an external computer via GPIB/LAN/USB interface.

Front panel

Rear panel

Undo recall/preset functions

The undo recall/preset functions are to return to the setting prior to the recall action or preset action respectively. These are to improve the productivity mainly in the manufacturing envirornment where the file recall and preset are frequently used.

8

Undo recall Undo preset

Compatible to 4287A LCR Meter for Drop-in Replacemement

The E4982A supports the functionalities of the industry-standard 4287A LCR meter while exceeding the performance such as measurement speed, accuracy, impedance range and so on. The E4982A’s SCPI commands are also compatible with the 4287A, which helps the users to make the smooth transition from 4287A to E4982A while leveraging the investment and expertise in the software. Refer to the migration guide available on

Agilent web site for more details on compatibility between the E4982A and 4287A,

Drop-in

Key specifications and functions

Frequency

List meas. function

Test signal level

E4982A

1 MHz to 3 GHz

201 points x 8 table

4.47 mV to 0.502 V/0.0894 mA to 10 mA

4287A

32 points x 8 table

4.47 mV to 0.502 V/0.0894 mA to 10 mA@ = < 1 GHz

4.47 mV to 0.447 V/0.0894 mA to 8.94 mA@ > 1 GHz

5.9 ms (typ) Meas. Time (INDEX)

Basic accuracy

Z meas. range

± 0.8 %

0.14 Ω to 4.8 kΩ (Mode3, 1 MHz, acc ≤ ± 10 %)

Calibration and compensation Open/short/load/low-loss cap., fixture electrical length comp., Open/short comp.

Rdc meas. function

Comparator

Data storage

Interface

Test Head

Size (mm)

Weight

0.9 ms (Mode1),

2.1 ms (Mode2),

3.7 ms (Mode3) (typ)

For contact check (on/off selectable)

13 bin

HDD (built-in), USB port

GPIB, LAN, Handler I/F, USB(USBTMC) I/F

1 m or 2 m (option), Right angle, 3.5 mm (female)

90 (W) x 24 (D) x 55 (H) mm

425 (W) x 235 (H) x 277 (D)

13 kg

± 1 %

0.2 Ω to 3 kΩ (1MHz, acc ≤ ± 10 %)

HDD (built-in), 1.44 MB FDD

GPIB, LAN, Handler I/F

425 (W) x 235 (H) x 445 (D)

16 kg

9

For R&D & Quality Assurance

Accurate impedance measurement up to

3 GHz

Characterization of components at operating frequencies in excess of 2 GHz is becoming common due to the development and evaluation of RF SMD inductors used in wireless communication equipment. The

E4982A employs the RF I-V measurement method.

The E4982A enables accurate measurement over an impedance range much wider than network analyzers (reflection coefficient method) while the upper frequency is limited for the auto-balancing bridge instruments.

Impedance measuremant technique comparison

(10% accuracy range)

Improved accuracy for high Q (low loss) measurements

For manual measurements, a low-loss capacitor as a phase calibration standard, in addition to open/ short/load calibration, improves the accuracy of

Q measurements as shown. In addition to calibration, electrical length compensation for a fixture with open/short compensation fully correct s the measurement error which is caused by the use of a test fixture. These functions realize high absolute measurement accuracy at the measurement plane, which in turn empowers accurate measurement of working standards.

Open/short/load

+

Low-loss (air) capacitor

(phase = –90 °)

Q accuracy @ 7-mm port (typical)

10

Calibration/compensation wizard functions

The E4982A offers you the sophisticated calibration/ compensation methods with wizard functions. The calibration/compensation wizard functions eliminate errors of troublesome calibration/compensation procedures, and it allows you to easily make the E4982A ready to measure accurately.

Calibration/compensation settings

Frequency characteristics by using list measurement function

In the area of research and development, the frequency characteristics of the device is important for the circuilt design. The E4982A’s list measurement function enable impedance measurements up to 201 multiple frequency points per table. The maximum of 1608 points is available (= 201 points max./table x 8 tables max.). The measurement results can be displayed by list or plot as list type.

Calibration wizard

Compensation wizard

List measurement (list)

11

List measurements (plot)

User defined function keys

The three function keys on the front panel offer quicker, one button access to soft keys which are frequently used. The default settings are F1 – Capture

Image, F2 – File Utility and F3 – Toggle Beeper

Warning. One of the ten specified soft keys (Capture

Image, File Utility, Toggle Beeper Warning, Save

State File, Save AutoRec.sta, Recall AutoRec.sta,

On-Screen Keyboard, Toggle Window Normal/Max,

Toggle Window Min/Max, Telnet localhost) can be set to each function key.

User defined function keys

User defined parameters

The user defined parameter allows you to create the user custom parameter. You can define the parameter other than the pre-defined parameter. In addition, the user defined parameter can be used with the BIN sorting function and can be compared with the limit.

User format dialog box

Context sensitive embedded help

In addition to the modern user interface and connectivity, the E4982A also provides the context sensitive embedded help, which increases the efficiency of operations in R&D, QA, and manufacturing.

12

Context sensitive embedded help

PC connectivity & Web-enabled analyzer

Standard GPIB/LAN/USB control interfaces provide a variety of paths for controlling the instrument. Using the

LAN interface, the E4982A can conveniently be controlled by a computer with Web browser. The Web server and browser web control executed by the VNC server allow the users to control the E4982A efficiently.

Web server/control + Excel usage example

Wide variety of accessories

When electronic components are evaluated, the test accessories should be suitable for their shape and size for accurate impedance measurement. Agilent offers various kinds of 7-mm test fixtures, which are compatible with the E4982A. You can select the appropriate one for your device’s size, shape, and application. The

16196A/B/C/D and 16197A test fixtures make RF impedance measurements up to 3 GHz. When the 16200B is used with the E4982A, a 7-mm test fixture, and an external dc bias source, dc bias current can be applied to devices such as the EMI filter (up to 1 GHz).

Solution example with 16196A

13

16200B external DC bias adapter

Wide Variety of Accessories

16196A/B/C/D SMD test fixture

• Frequency range: DC to 3 GHz

• Operating temperature range: –55 to +85 °C

• Accommodated SMD size:

• 16196A: 1608 (mm)/0603 (inch)

• 16196B: 1005 (mm)/0402 (inch)

• 16196C: 0603 (mm)/0201 (inch)

• 16196D: 0402 (mm)/01005 (inch)

16192A SMD test fixture

• Frequency range: DC to 2 GHz

• Operating temperature range: –55 to +85 °C

• Accommodate d SMD size: See Figure

16197A SMD test fixture

• Frequency range: DC to 3 GHz

• Operating temperature range: –55 to +85 °C

• Accommodated SMD size:

• 3225 (mm)/1210 (inch)

• 3216 (mm)/1206 (inch)

• 2012 (mm)/0805 (inch)

• 1608 (mm)/0603 (inch)

• 1005 (mm)/0402 (inch)

• 0603 (mm)/0201 (inch) (option)

16194A High temperature component test fixture

• Frequency range: DC to 2 GHz

• Operating temperature range: –55 to +200 °C

• Accommodate d SMD size: See Figure

16200B External DC bias adapter

• Frequency range: 1 MHz to 1 GHz

• External DC bias: 5 A max., 40 V

(at the BNC connector from the external dc bias source)

• Operating temperature range: 0 to +55 °C

16196A/B/C, 16196D has a different cap shape

16192A

16197A

Accommodated SMD size

16200B

16194A

14

Ordering Information

E4982A LCR Meter furnished accessories

• Test head with 1 m test cable

• N (m)-SMA (f) Adapter

• Wrench for 3.5/SMA connector

• Power cord

• Installation guide

• CD-ROM IO libraries

Options

• E4982A-004 Add working standard set

• E4982A-019 Standard hard disk drive

1

• E4982A-020 Add test fixture extension cable set (1 m)

• E4982A-700 16195B calibration kit

• E4982A-710 Test fixture stand

• E4982A-720 3.5 mm to 7 mm coaxial adapter

• E4982A-810 Add keyboard

• E4982A-820 Add mouse

• E4982A-1A7 ISO 17025 compliant calibration

• E4982A-A6J ANSI Z540 compliant calibration

Cabinet options

• E4982A-1CM Rack flange kit

• E4982A-1CN Front handle kit

• E4982A-1CP Handle/rack mount kit

Accessories

2

16196A Parallel electrode SMD test fixture

Option 16196A-710 Add magnifying lens and tweezers

Option 16196A-ABA U.S. – English localization

Option 16196A-ABJ Japan – Japanese localization

16196B Parallel electrode SMD test fixture

Option 16196B-710 Add magnifying lens and tweezers

Option 16196B-ABA U.S. – English localization

Option 16196B-ABJ Japan – Japanese localization

16196C Parallel electrode SMD test fixture

Option 16196C-710 Add magnifying lens and tweezers

Option 16196C-ABA U.S. – English localization

Option 16196C-ABJ Japan – Japanese localization

16196D Parallel electrode SMD test fixture

Option 16196D-710 Add magnifying lens and tweezers

Option 16196D-ABA U.S. – English localization

Option 16196D-ABJ Japan – Japanese localization

16196U Maintenance kits for 16196X

Option 16196U-010 Upper electrode set for 16196A/B/C

(5 ea)

Option 16196U-020 Upper electrode set for 16196D

(5 ea)

Option 16196U-100 1608 (mm) short plate set (5 ea)

Option 16196U-110 1608 (mm) lower electrode set (5 ea)

Option 16196U-200 1005 (mm) short plate set (5 ea)

Option 16196U-210 1005 (mm) lower electrode set (5 ea)

Option 16196U-300 0603 (mm) short plate set (5 ea)

Option 16196U-310 0603 (mm) lower electrode set (5 ea)

Option 16196U-400 0402 (mm) short plate set (5 ea)

Option 16196U-410 0402 (mm) lower electrode set (5 ea)

16197A Bottom electrode SMD test fixture

Option 16197A-001 Add 0201 (inch)/0603 (mm) device guide set

Option 16197A-ABA U.S. – English localization

Option 16197A-ABJ Japan – Japanese localization

16192A Parallel electrode SMD test fixture

Option16192A-010 EIA/EIAJ industry sized short bar set

Option 16192A-701 Short bars set

(1 × 1 × 2.4, 1.6 × 2.4 × 2,

3.2 × 2.4 × 2.4, 4.5 × 2.4 × 2.4) mm

Option 16192A-710 Add magnifying lens and tweezers

16194A High temperature component test

fixture

Option 16194A-010 EIA/EIAJ industry sized short bar set

Option 16192A-701 Short bars set

(1 × 1 × 2.4, 1.6 × 2.4 × 2, 3.2

× 2.4 × 2.4, 4.5 × 2.4 × 2.4) mm

16200B External DC bias adapter

16190B Performance test kit, 7-mm

15

1. Option 019 is the only hard disk option for the E4982A. Must choose this option when ordering the E4982A.

2. For more details, refer to Accessories Selection Guide for Impedance

Measurements.

www.agilent.com

Agilent Email Updates www.agilent.com/find/emailupdates

Get the latest information on the products and applications you select.

www.lxistandard.org

LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium.

Agilent Channel Partners www.agilent.com/find/channelpartners

Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience.

Agilent Advantage Services is committed to your success throughout your equipment’s lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership.

You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world.

www.agilent.com/find/advantageservices www.agilent.com/quality

For more information on Agilent

Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at:

www.agilent.com/find/contactus

Americas

Canada

Brazil

(877) 894 4414

Mexico 01800 5064 800

United States

(11) 4197 3600

(800) 829 4444

Asia Pacific

Australia

China

Hong Kong

India

Japan

Korea

Malaysia

Singapore

Taiwan

1 800 629 485

800 810 0189

800 938 693

1 800 112 929

0120 (421) 345

080 769 0800

1 800 888 848

1 800 375 8100

0800 047 866

Other AP Countries (65) 375 8100

Europe & Middle East

Belgium

Denmark

Finland

France

32 (0) 2 404 93 40

45 45 80 12 15

Germany

Ireland

358 (0) 10 855 2100

0825 010 700*

*0.125 €/minute

49 (0) 7031 464 6333

1890 924 204

Israel 972-3-9288-504/544

Italy

Netherlands

Spain

Sweden

39 02 92 60 8484

31 (0) 20 547 2111

34 (91) 631 3300

0200-88 22 55

United Kingdom 44 (0) 118 927 6201

For other unlisted countries:

www.agilent.com/find/contactus

Revised: January 6, 2012

Product specifications and descriptions in this document subject to change without notice.

© Agilent Technologies, Inc. 2012

Published in USA, August 9, 2012

5990-9911EN

advertisement

Related manuals

advertisement