Intelligent Photoelectric Smoke Detector for Difficult Environments


Add to my manuals
2 Pages

advertisement

Intelligent Photoelectric Smoke Detector for Difficult Environments | Manualzz

Intelligent Photoelectric

Smoke Detector for

Difficult Environments

Filtrex

®

provides protection in dirty, dusty environments that tend to cause false alarms with standard smoke detectors.

Features

• Intelligent communications

• High density filter removes particulate down to 32 microns

• Air delivery system is separately powered and fully supervised

• Filter is easily field replaceable

• Resistant to water spray in applications where occasional hosedown cleaning is performed

• Optional remote LED accessory

• Rotary decade address switches

• Compatible with 200 and 500 Series products’ protocol

• No modification required to panels compatible with System Sensor intelligent photoelectric smoke detectors

The Filtrex smoke detector from System Sensor provides early warning smoke detection in difficult environments where traditional smoke detectors are not practical.

Operation:

Using a small air intake fan and a high density replaceable filter, air and smoke are drawn into a photoelectric sensing chamber while airborne particulate and water spray are removed. When the filter becomes too clogged to draw adequate air into the sensing chamber, power is cut from the detector, causing a trouble signal at the fire alarm control panel. When the filter is replaced, power-up is automatic.

Applications:

Animal research facilities

Institutional laundry facilities

Amusement parks

Zoos

Performance theatres

Loading docks

Paper mills

Textile mills

Agency Listings

S911

Specifications, Filtrex

®

Smoke Detector

Physical/Operating Specifications

Size

Weight

Temperature Range

Humidity Range

Air Intake Fan

Filter

Electrical Specifications

Signaling Line Circuit Supply Range

Detector Current (max. avg.)

External/Auxiliary Power Supply Voltage Range

External/Auxiliary Power Supply Maximum Current

External/Auxiliary Power Supply Avg. Current

3.5 in (8.9 cm) H × 6.1 in (15.5 cm) Dia. in B501B-FTX base

7.3 oz. (207 grams)

32ºF to 122°F (0°C to 50° C)

10% to 93% noncondensing

On 5 seconds every 30 seconds

Airflow checked every 4 hours

15 to 32 VDC

250 µA @ 24 VDC (without communication)

360 µA @ 24 VDC (one communication every 5 seconds with LED enabled)

15 to 30 VDC (filtered)

123 mA

27 mA

Wiring Diagram

+

AUX

AUX+

1(+)

2(–) 3(R

A) 4(S

)

AUX

AUX+

1(+)

2(–) 3(RA)

4(S)

AUX.

POWER

SUPPLY

+

Ordering Information

Part No.

FTX-P1

FTX-P1A

Bases

B501B-FTX

B501B-FTXA

Accessories

RF-FTX

RA400Z /RA100Z

M02-04-01

M02-09-00

Description

Photoelectric smoke detector

Photoelectric smoke detector, (Canadian)

Flanged adapter base, 6.1 in (15.5 cm)

Flanged adapter base, 6.1 in (15.5 cm), (Canadian)

Replacement filter cover assembly (6 pack)

Remote LED annunciator, fits U.S. single gang electrical box

Test magnet

Test magnet with telescoping handle

3825 Ohio Avenue • St. Charles, IL 60174

Phone: 800-SENSOR2 • Fax: 630-377-6495

©2009 System Sensor.

Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.

A05-0985-003 • 7/09 • #2205

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement