SANITARY DRAIN/SEWER (ABOVE GRADE) SAN SANITARY DRAIN/SEWER (BELOW GRADE) COMPRESSED AIR FILTER/WATER SEPARATOR PRESSURE REDUCING VALVE ST STORM DRAIN SEWAGE (BELOW GRADE) PNEUMATIC CONTROL VALVE (3 WAY) SST SECONDARY STORM DRAIN SEWAGE (ABOVE GRADE) SOLENOID OR MOTORIZED VALVE (E) EXISTING PIPING TO REMAIN SYMBOL(E) IN-LINE PUMP (PLAN) SOLENOID OR MOTORIZED CONTROL VALVE (3 WAY) SANITARY VENT PIPING GREASE WASTE (BELOW GRADE) THE PIPING INDICATED ON THESE PLANS ARE DIAGRAMMATIC. ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES PRIOR TO INSTALLATION. CONTRACTOR SHALL COORDINATE ROUTING OF ALL PIPING WITH EXISTING CONDITIONS AND SHALL PROVIDE ANY NECESSARY OFFSETS, REROUTING, TEES, ELBOWS, ETC. REQUIRED FOR A COMPLETE AND COORDINATED INSTALLATION. C. PROVIDE ALL WORK IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES. OBTAIN ALL REQUIRED PERMITS. D. PROVIDE ALL REQUIRED EXCAVATION, BACKFILL AND COMPACTION FOR ALL UNDERGROUND WORK. E. FIELD VERIFY EXACT LOCATION, DEPTH, COMPOSITION AND CONDITION OF ALL PIPING, VALVES AND SYSTEMS AS REQUIRED FOR WORK OF THE CONTRACT. F. PROVIDE CUTTING, CORING AND PATCHING OF ALL WALLS, SLABS AND DECKS AS REQUIRED FOR WORK SHOWN. COORDINATE ALL WORK WITH OWNER AND GENERAL CONTRACTOR AND ALL TRADES. G. PROVIDE SCHEDULE 40 BLACK STEEL PIPE SLEEVES FOR ALL UNDERGROUND PIPING PASSING THROUGH OR UNDER FOOTINGS, WALLS, FOUNDATION WALLS, SLABS FLOORS AND/OR UNDERGROUND STRUCTURES. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. H. WHERE PIPING IS LOCATED OVER FOOTINGS AND/OR OTHER UNDERGROUND STRUCTURES, ROLL DOWN AS REQUIRED TO CONNECT TO SYSTEMS NOTED. PROVIDE ALL REQUIRED OFFSETS, FITTINGS AND CONNECTIONS. PUMP (SCHEMATIC) SECONDARY STORM DRAIN SEWAGE (BELOW GRADE) GW 3.) IF REQUIRED, PROVIDE SHUT DOWNS AND TIE-INS DURING OFF HOURS TO AVOID DISRUPTION OF BUILDING SYSTEMS. COORDINATE ALL SHUT DOWN REQUIREMENTS PRIOR TO SUBMITTING BID (INCLUDE ALL REQUIRED DURING OFF HOURS IN BID). STEAM TRAP STORM DRAIN SEWAGE (ABOVE GRADE) V B. PNEUMATIC VALVE ST SST THE EXISTING PIPING INDICATED ON THESE PLANS SHALL BE VERIFIED IN THE FIELD FOR EXACT LOCATIONS, QUANTITY, AND PIPE SIZES. FLEX CONNECTION TRIPLE DUTY VALVE EXPANSION JOINT WITH GUIDES RELIEF VALVE EXISTING PIPING TO BE REMOVED 4.) THE CONTRACTOR SHALL OBTAIN AND PAY ALL FEES RELATED TO PERMITTING, INSPECTIONS, TAP-ON FEES, ETC. 5.) CONTRACTOR SHALL COORDINATE ANY PLUMBING OR PIPING SYSTEM SHUTDOWN WITH THE OWNER 48 HOURS IN ADVANCE. 6.) CONTRACTOR SHALL COORDINATE AND PROVIDE ALL NECESSARY PIPING & PLUMBING FITTINGS, PIPING, MISCELLANEOUS ITEMS REQUIRED FOR A COMPLETE INSTALLATION OF ALL PLUMBING RELATED ITEMS. 7.) ALL WORK SHALL BE COORDINATED WITH THE EQUIPMENT VENDORS. PIPE ANCHOR PIPE TURNED UP TEMPERATURE & PRESSURE RELIEF VALVE PIPE TURNED DOWN HOSE BIBB OR DRAIN VALVE BRANCH OFF BOTTOM OF PIPE PIPE GUIDE CWS WALL HYDRANT EQUIPMENT TO BE REMOVED NON-FREEZE CWS & HWS WALL HYDRANT IN BOX REDUCER NON-FREEZE ROOF HYDRANT PIPE BREAK PIPE CONTINUATION NEW CONNECTION TO EXIST. UNION BUTTERFLY VALVE FLANGE GATE VALVE - NRS GATE VALVE - OS&Y PRESSURE GAUGE GLOBE VALVE THERMOMETER REMOVE TO THIS POINT X PLUG VALVE 1 WATER HAMMER ARRESTER SHUT-OFF VALVE (GATE, BALL, OR BUTTERFLY - REFER TO SPECS) 3 11.) THE PLUMBING SYSTEM SHALL BE TESTED AS REQUIRED BY STATE AND LOCAL CODE OR BY THE REQUIREMENTS OF THE LOCAL PLUMBING INSPECTOR. L. THE ENTIRE DOMESTIC WATER SYSTEM (EXISTING/NEW) SHALL BE DISINFECTED IN ACCORDANCE TO THE LOCAL CODE & HEALTH DEPARTMENT REQUIREMENTS. M. PROVIDE BARRIER TYPE SEAL DEVICE ON ALL FLOOR DRAINS. N. REFER TO ARCHITECTURAL DRAWINGS AND THE PROJECT SPECIFICATIONS FOR ANY PROJECT PHASING REQUIREMENTS. 12.) 13.) THE BACKFLOW PREVENTION DEVICE SHALL BE INSTALLED PER STATE AND LOCAL CODE & PER AUTHORITY HAVING JURISDICTION REQUIREMENTS. 14.) THE CONTRACTOR SHALL NOT SCALE THESE DRAWINGS. DEMOLITION KEYNOTE ℄ CLG CO CONN CWS COND DB DEG DF DIA DN DPCO DRS DW DWG DWH (E) EA ELEV ENT EQ EQUIP EQUIV ETR °F FAI FCO FD FIN FL FLA FPWH FT GA GALV GC GPD GPH GPM GW HT HB HD HP HR HTR HWS HWR ID INCL INV K KW LAV MC MED MFR MISC MIN MSS MTD (N) NC NH No NO NTS OD ODWH OPG OS OT OZ PART PDR PERF PH PIV POS PRESS PS PSI PSIG NEW NORMALLY CLOSED NO HUB NUMBER NORMALLY OPEN NOT TO SCALE OUTSIDE DIMENSION ON DEMAND WATER HEATER OPENING OPEN SITE OFF TOP OUNCE PARTIAL PLENUM DRAIN PERFORATED PHASE POST INDICATOR VALVE POSITIVE PRESSURE PRESSURE SWITCH POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE PSIA POUNDS PER SQUARE INCH ABSOLUTE PT PRESSURE TRANSMITTER PV PLUG VALVE PVC POLYVINYL CHLORIDE PVS POLYVINYL COATED STEEL QUAN QUANTITY RD ROOF DRAIN REL RELIEF REQD REQUIRED RL RAIN LEADER RM ROOM RP RECIRCULATION PUMP RPM REVOLUTIONS PER MINUTE SA SHOCK ABSORBER SCH SCHEDULE SCHEM SCHEMATIC SK STAINLESS STEEL SINK SPEC SPECIFICATION SPS SUMP PUMP SYSTEM SQ SQUARE S/S SERVICE SINK SS STAINLESS STEEL ST STORM SST SECONDARY STORM STD STANDARD STL STEEL STR STRUCTURAL SUP SUPPLY SYS SYSTEM S/SHO SAFETY SHOWER TYP TYPICAL UR URINAL VB VACUUM BREAKER VS VIVARIUM SINK VTR VENT THRU ROOF W WIDTH W/ WITH WHA WATER HAMMER ARRESTER W/O WITHOUT WC WATER CLOSET WM WATER METER YCO YARD CLEAN OUT G INEER AR ES C CERT. NO. 52904 NO CH G S. BL YT AS S O CI AT I TE C TUR A CH L AR RT H CAROLI NA L OT TE , N . C 9/9/2016 © 2016 LaBella Associates TOWN OF DAVIDSON 216 South Main Street, Davidson, NC 28036 WASHER BOX PLUMBING SPECIFICATION NOTES ABBREVIATIONS ABOVE FINISHED FLOOR ACCESS PANEL BACK FLOW PREVENTER BUILDING BASEMENT COMPRESSED AIR CUBIC FEET PER HOUR CAST IRON CENTER LINE CEILING CLEAN OUT CONNECTION COLD WATER SUPPLY CONDUCTOR DRAIN BOX DEGREE DRINKING FOUNTAIN DIAMETER DOWN DECK PLATE CLEAN OUT DARK ROOM DOUBLE BOWL SINK DOMESTIC WATER DRAWING DOMESTIC WATER HEATER EXISTING EACH ELEVATION ENTERING EQUAL EQUIPMENT EQUIVALENT EXISTING TO REMAIN DEGREES FAHRENHEIT FRESH AIR INTAKE FLOOR CLEANOUT FLOOR DRAIN FINISHED FLOOR FULL LOAD AMPS FREEZE PROOF WALL HYDRANT FEET GAUGE GALVANIZED GENERAL CONTRACTOR GALLONS PER DAY GALLONS PER HOUR GALLONS PER MINUTE GREASE WASTE HEIGHT HOSE BIBB HEAD (SEE SCHEDULES) HORSE POWER HOSE REEL HEATER HOT WATER SUPPLY HOT WATER RETURN INTERNAL DIAMETER INCLUDING INVERT TYPE OF COPPER TUBING KILOWATT LAVATORY MECHANICAL CONTRACTOR MEDIUM MANUFACTURER MISCELLANEOUS MINIMUM MOP SERVICE SINK MOUNTED AI LA WB P-TRAP AFF AP BFP BLDG BSMT CA CFH CI PROVIDE SINGLE HOSE BIBB WITH VACUUM BREAKER (HB) UNDER LAVATORY(S) IN ALL TOILET ROOMS WITH FLOOR DRAINS. ONE REQUIRED PER ROOM. ALL PIPING PENETRATIONS THROUGH NEW, EXISTING WALL, OR FLOOR SHALL BE SEALED TO EQUAL THE RATING OF THE NEW, EXISTING WALL OR FLOOR. KEYNOTE X WHA COORDINATE ALL VENT TERMINATIONS ABOVE ROOF WITH HVAC CONTRACTOR. ALL VENT TERMINATIONS ABOVE ROOF SHALL BE A MINIMUM 25'-0" AWAY FROM ANY HVAC OUTSIDE AIR INTAKE (ROOFTOP UNIT, LOUVER, ETC.). 10.) STRAINER BALL VALVE K. SEAL 030515 EN CR ALL PLUMBING & PIPING SYSTEMS SHALL BE SUPPORTED AS REQUIRED BY THE STATE AND LOCAL CODE REQUIREMENTS AND PER MANUFACTURER'S RECOMMENDATIONS. E S S IO N EL R A TI ON 9.) VALVE(S) IN VERTICAL PIPE CONNECT TO SITE PIPING OUTSIDE BUILDING AS SHOWN. PROVIDE ALL REQUIRED OFFSETS, FITTINGS AND CONNECTIONS. FIELD VERIFY EXACT LOCATION, DEPTH AND COMPOSITION OF SITE SERVICES AND COORDINATE ALL WORK WITH SITE CONTRACTOR. OF I PO J. O H C ARO L RT C. CLEAN OUT CO NON-FREEZE CWS WALL HYDRANT IN BOX PITCH ALL SANITARY, WASTE, AND STORM PIPING AS FOLLOWS: PIPING 3" AND SMALLER, PITCH AT 2 PERCENT (14" PER FOOT) MINIMUM, PIPING 4" AND LARGER, PITCH AT 1 PERCENT (18" PER FOOT) MINIMUM. OR VALVE ON VERTICAL I. AL CWS & HWS WALL HYDRANT FLOOR/DECK PLATE CLEAN OUT (PLAN VIEW) NC LICENSE NO. C-0430 P. FCO/DPCO THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL UNDER SLAB PIPING WITH EXISTING STRUCTURAL FOUNDATIONS. UNDERGROUND UTILITY LOCATIONS SHALL BE VERIFIED PRIOR TO ANY WORK BEING PERFORMED. CONTRACTOR SHALL REPAIR OR REPLACE ALL PIPING NOT IN PROPER WORKING ORDER OR DAMAGED DURING INSTALLATION OF THE NEW UNDERSLAB PIPING. 8.) NA BRANCH OFF TOP OF PIPE FLOOR DRAIN OR FLOOR SINK FD www.labellapc.com . ANGLE VALVE DOMESTIC HOT WATER RECIRCULATION SAN 2.) B COMPRESSED AIR QUICK DISCONNECT W/O CHECK LA BALANCING VALVE DOMESTIC COLD WATER DOMESTIC HOT WATER SUPPLY Engineering Architecture Environmental Planning 455 South Main Street Davidson, NC 28036 P: (704) 439-2931 ED WATER SERVICE (FIRE PROTECTION ONLY) DO NOT SHUT DOWN ANY PLUMBING, FIRE PROTECTION, NATURAL GAS, OR RELATED SYSTEMS WITHOUT BUILDING OWNER'S PRIOR WRITTEN APPROVAL. FOLLOW ALL OWNER REQUIREMENTS AND SHUT DOWN PROCEDURES AS WELL AS ALL REQUIREMENTS OF THIS PROJECT. R E GI S TE R F A. E CHECK VALVE THE ENTIRE PLUMBING SYSTEM SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE PLUMBING CODE OF NORTH CAROLINA AND LOCAL PLUMBING INSPECTOR. H WATER SERVICE (DOMESTIC OR COMBINED) 1.) COMPRESSED AIR QUICK DISCONNECT W/ CHECK N W GENERAL NOTES GENERAL PLUMBING NOTES PR PLUMBING SYMBOLS 1. SCOPE OF WORK 5. SANITARY/STORM DRAINAGE AND VENT PIPING 7. B. BELOW GRADE EARTH SHALL BE EXCAVATED TO A MINIMUM DEPTH WITH AN A. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS, EVEN SURFACE TO INSURE SOLID BEARING OF PIPE FOR ITS A. ABOVE GRADE: -2" AND BELOW: AND LABOR TO SATISFY A COMPLETE WORKING SYSTEM WHETHER SPECIFIED OR IMPLIED. B. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH THE NATIONAL STANDARD PLUMBING CODE (LATEST SCH. 40 GALV. STL. PIPE WITH SCREWED ENTIRE LENGTH. ENDS OR SCH. 40 PVC WITH SOLVENT -INTERIOR: THE PIPE SHALL BE INSTALLED (UNLESS OTHER- JOINTS OR DWV COPPER WITH SOLDER WISE SPECIFIED) A MINIMUM OF 4 INCHES BELOW JOINTS. ALL SOLDER TO BE "NO LEAD" THE BOTTOM OF THE SLAB AND SHALL NOT BE TYPE. IN ANY DIRECT CONTACT WITH THE CONCRETE AT ANY POINT. EDITION), ALL LOCAL CODES, AND ALL OTHER REGULATIONS GOVERNING WORK OF THIS NATURE. -3" AND ABOVE: -EXTERIOR: SCH. 40 PVC WITH SOLVENT JOINTS. THE WATER PIPE SHALL HAVE A MINIMUM OF 42" OF COVER AND THE SANITARY WASTE PIPE SHALL HAVE A MINIMUM OF 24" OF COVER. C. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL, EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF THE CONDITIONS THAT MAY EFFECT THE WORK. NO B. BELOW GRADE: FIRE STATION #2 SERVICE WT. CAST IRON WITH BELL AND ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO SPIGOT JOINTS OR SCH. 40 PVC WITH MAKE SUCH EXAMINATIONS. SOLVENT JOINTS. 8. MISCELLANEOUS 19436 DAVIDSON CONCORD ROAD, DAVIDSON, NC 28036 A. COORDINATE INSTALLATION OF ALL ROOF FLASHING AT D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR C. PVC PIPING SHALL NOT BE USED IN AIR PLENUM CEILINGS ROOF PENETRATION. AND SHALL NOT CROSS FIRE RATED WALLS, CEILINGS, "APPROVED EQUAL" BY ENGINEER OR ARCHITECT. OR FLOORS. 2. B. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS. VERIFY ALL FIGURES, CONDITIONS, AND DIMENSIONS PERMITS D. DRAINAGE PIPING SHALL BE RUN AS STRAIGHT AS POSSIBLE AT THE JOB SITE. AND SHALL HAVE LONG TURN FITTINGS. A. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICA- C. THE PLUMBING PLANS ARE INTENDED TO BE DIAGRAMMATIC TIONS AND PAY ANY AND ALL FEES. 3. SHOP DRAWINGS E. DRAINAGE PIPING 3" SIZE AND SMALLER SHALL RUN AT A MATIC AND ARE BASED ON ONE MANUFACTURE'S EQUIP- UNIFORM GRADE OF AT LEAST 1/4" PER FOOT, AND PIPING MEANT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM 3 09/07/16 LARGER THAN 3" SHALL BE RUN AT A GRADE OF NO LESS IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL 2 08/15/16 THAN 1/8" PER FOOT. THE DETAILS OF THE EQUIPMENT. THE CONTRACTOR 1 08/10/16 NO: DATE: SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIP- A. SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR F. ALL VENT PIPING SHALL BE SLOPED TO DRAIN BACK TO EQUIPMENT/FIXTURES TO THE ARCHITECT OR ENGINEER MEANT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL FIXTURES. FOR APPROVAL. THE CONTRACTOR SHALL SUBMIT THREE FIT IN THE AVAILABLE SPACE. 4. A. UNDERGROUND: 9. ALL STUB-INS AND/OR SLAB OR WALL PENETRATION TO BE PROVIDE TYPE "K" SOFT DRAWN COPPER PER NATIONAL STANDARD PLUMBING CODE. ALL PIPING TUBING WITH BRAZED CONNECTIONS. PENETRATIONS OF BUILDING FOUNDATIONS OR FOOTINGS SHALL BE SLEEVED. B. ABOVE GROUND: TESTING DRAWN BY: A. REVIEWED BY: PLUMBING SYSTEMS SHALL BE FLOW AND PRESSURE TESTED IN ACCORDANCE WITH STANDARD PRACTICE AND THE NATIONAL STANDARD PLUMBING CODE. CONTRACTOR SHALL SCOPE NEW LINES AND PROVIDE REPORT WITH VIDEO. COPPER OR BRASS FITTINGS. ALL SOLDER 10. 7. A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE A. ABOVE GRADE ISSUED FOR: CONSTRUCTION ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT MATERIAL AND FITTINGS AS LISTED IN 'TABLE 605.4 - WATER STRUCTURE IN A NEAT AND WORKMANLIKE MANNER. PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S DISTRIBUTION PIPE' , AND 'TABLE 605.5 PIPE FITTINGS' THE USE OF WIRE AND PERFORMED METAL TO SUPPORT EXPENSE. OF THE PLUMBING CODE OF NEW YORK STATE. PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS SHALL BE AS SPECIFIED IN CHAPTER 8 OF THE NATIONAL STANDARD PLUMBING CODE. 07.25.16 DRAWING NAME: GUARANTEED FOR A PERIOD OF ONE(1) YEAR FROM DATE CONTRACTOR MAY SUBMIT OPTIONAL CODE APPROVED FIBERGLASS INSULATION. BB GUARANTEE PIPE SUPPORTS TO BE "NO LEAD" TYPE. C. ALL HOT WATER PIPING TO BE INSULATED WITH 1" PAV/DWM DATE: PROVIDE TYPE "L" HARD DRAWN COPPER TUBING WITH 125 PSI SOLDER JOINTS, DESCRIPTION: 2151374 DOMESTIC WATER SUPPLY PIPING 6. PERMITTING COMMENTS PROJECT NUMBER: G. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER FLASHING OF THE VENT PIPING RUN THROUGH THE ROOF. ADDENDUM 2 REVISIONS SETS OF SHOP DRAWINGS AND THEY SHALL BE CLEARLY LABELED. PERMITTING COMMENTS B. FOR THE SAME PERIOD, THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES PLUMBING SYMBOLS AND ABBREVIATIONS CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM. D. ALL COLD WATER PIPING TO BE INSULATED WITH 1/2" FOAM INSULATION. E. COMPLY WITH NSF 14 FOR PLASTIC, POTABLE DOMESTIC WATER DRAWING NUMBER: MECKLENBURG PIPING AND COMPONENTS. COUNTY INCLUDING MARKING "NSF-pw" ON PIPING. CODE ENFORCEMENT F. The COMPLY WITH NSF 61 FOR POTABLE DOMESTIC WATER Design In These Construction PIPING AND COMPONENTS. Documents Have Been Reviewed For Compliance With The State Building Code. It Is The Responsibility Of The Contractor To Construct This Project With Good Engineering Practice And In Compliance With The North Carolina State Building Code. P-001 SH-1 4"SAN LI-1 4"SAN 3 4"SAN FCO 4"OW MSB-1 FD 5 4 17 4 BEDROOM 110 2"V 13 VESTIBULE 117 4"OW 4"SAN WB LAUNDRY 116 PROVIDE 4" SANITARY W/ DEEP SEAL P-TRAP UP TO FD/TD 4 PROVIDE 2"V PIPE UP. 5 PROVIDE 3"SAN PIPE UP. 6 PROVIDE TD-1 AND CONNECT TO CB-1. 7 PROVIDE CB-1 AND CONNECT TO 4"WASTE PIPE. 8 PROVIDE OI-1 AND ALL ASSOCIATED ACCESSORIES. CONNECT TO 4"SAN PIPE TO OUTLET, 4"OW PIPE TO INLET, AND 2"V PIPE IN SLAB. 9 PROVIDE OI-2 AND ALL ASSOCIATED ACCESSORIES. CONNECT TO 4"SAN AND 2"V PIPES IN SLAB. 10 PROVIDE 1-1/4" G PIPE UP. REFER TO P101 AND CIVIL DRAWINGS FOR CONTINUATION. 11 PROVIDE 2" CWS PIPE UP. REFER TO P101 DRAWING FOR CONTINUATION. 12 PROVIDE 4"FP PIPE UP. REFER TO FP101 DRAWING FOR CONTINUATION. 13 PROVIDE 4"SAN UP. www.labellapc.com 2 4"SAN 4"OW 2 EXERCISE 112 LOCKER ROOM 113 L-1 4"SAN 4"OW 19 3"SAN 3 4"SAN 2"V 4"SAN 3 4 N PROVIDE 4" SAN PIPE UP TO WALL CO. 19 EXTEND 4" OW PIPING TO EXTERIOR OIL SEPARATOR, SEE CIVIL DRAWINGS FOR PIPE CONTINUATION. 52904 AR RT H CAROLI NA LOT TE , N . C . 9/16/2016 9/9/2016 L-1 TOWN OF DAVIDSON 2"V 4"SAN 3"SAN 4"OW 18 R A TI ON PROVIDE 3" DEEPSEAL P-TRAP AT SD/MSB. C CERT. NO. NO CH G S. BLYT ES PO 17 G INEER AR ASSOCI AT I TE C TU R A CH L OR TD-1 PROVIDE 4" SAN PIPE. REFER TO CIVIL DRAWINGS FOR CONTINUATION. AI LA C. TD-1 16 SEAL 030515 EL © 2016 LaBella Associates P-1 6 PROVIDE 2" CWS UNDERGROUND PIPE. REFER TO CIVIL DRAWINGS FOR CONTINUATION. ES S IO N I P. 1 5 6 15 OF EN CR BEDROOM 109 PROVIDE 4" FIRE SUPPRESSION UNDERGROUND PIPE. REFER TO CIVIL DRAWINGS FOR CONTINUATION. H CARO L AL 14 T OR NA CORRIDOR 108 NC LICENSE NO. C-0430 B 16 5 FD BEDROOM 111 LA 4"SAN 4"SAN 4"SAN 4 PROVIDE 4" SAN PIPE UP TO CO. ED FD 2 4 R E GI S TE R 3 PROVIDE 4" SAN PIPE UP TO WC. E 4 1 Engineering Architecture Environmental Planning 455 South Main Street Davidson, NC 28036 P: (704) 439-2931 H STORAGE 115 M 17 3"SAN 4" SA N 10 KEY NOTES: PR SS-1 3 5 3"SAN 1-1/4"G DECONTAMINATION 114 MEN 107 216 South Main Street, Davidson, NC 28036 4 4"SAN 2 AN S 3" 2"V 5 17 4 KITCHEN SK-1 105 SH-1 SH-1 2"V 2 17 FCO 4"SAN WOMEN 106 4 4"SAN 2 3"SAN FCO L-1 P-1 1 5 4"OW 7 7 4 4"OW 4"OW WCO PANTRY 104 LINEN 103 4"OW 4 4"OW 4"OW CB-1 CB-1 FIRE STATION #2 4"OW 19436 DAVIDSON CONCORD ROAD, DAVIDSON, NC 28036 WCO 2 BAY 1 118 BAY 2 119 6 6 TD-1 TD-1 5 9/16/16 INTERACTIVE REVIEW COMMENTS 4 9/14/16 INTERACTIVE REVIEW COMMENTS 3 09/07/16 PERMITTING COMMENTS 2 08/15/16 1 08/10/16 NO: DATE: ADDENDUM 2 PERMITTING COMMENTS DESCRIPTION: REVISIONS PROJECT NUMBER: LIVING 102 2151374 DRAWN BY: PAV/DWM REVIEWED BY: BB ISSUED FOR: CONSTRUCTION DATE: 07.25.16 DRAWING NAME: OFFICE 101 ENTRY 100 11 2" SPRINKLER CLOSET 101A 12 455 South Main Street Davidson, NC 28036 P: (704) 439-2931 UNDER SLAB PLUMBING FLOOR PLAN Engineering Architecture Environmental Planning www.labellapc.com 4" NC LICENSE NO. C-0430 A H L L A R S S O I . P A C H I E T L A B L A . C L O F D P O I A R T H C N CRA A G R I C N I A R E G IS T R E E S N A R . NO O T O I T CERT. NO. 52904 N H T LO T E , A L E YT H E T C U R . . E R R O L R B C A N I NE R I G S E O L E S S ON SEAL 030515 E C O RP A CAR T N C 9/16/2016 9/9/2016 © 2016 LaBella Associates TOWN OF DAVIDSON 216 South Main Street, Davidson, NC 28036 FIRE STATION #2 19436 DAVIDSON CONCORD ROAD, DAVIDSON, NC 28036 5 4 9/16/16 9/14/16 INTERACTIVE REVIEW COMMENTS INTERACTIVE REVIEW COMMENTS 3 2 09/07/16 08/15/16 1 NO: 08/10/16 DATE: PERMITTING COMMENTS ADDENDUM 2 PERMITTING COMMENTS DESCRIPTION: REVISIONS PROJECT NUMBER: 2151374 DRAWN BY: REVIEWED BY: ISSUED FOR: DATE: CONSTRUCTION 07.25.16 DRAWING NAME: DRAWING NUMBER: 00/00/0000 00:00AM FLPTH 15 14 1 UNDERSLAB P100 1/4" = 1'-0" PLUMBING FLOOR PLAN N 4" DRAWING NUMBER: MECKLENBURG COUNTY CODE ENFORCEMENT 2" The Design In These Construction Documents Have Been Reviewed For Compliance With The State Building Code. It Is The Responsibility Of The Contractor To Construct This Project With Good Engineering Practice And In Compliance With The North Carolina State Building Code. P-100 TOTAL GAS LOAD = 580 MBH TOTAL DEVELOPED LENGTH = 150' GAS PRESSURE = <2.0 PSI GAS METER BY GAS CO. GAS PIPING SIZED PER TABLE 402.4(2) OF THE NCSBC: FUEL GAS CODE 2012 11 KEY NOTES: SS-1 2 4 17 1 PROVIDE WC-1 AND ALL ASSOCIATED ACCESSORIES. CONNECT TO 1/2"CW PIPE IN WALL AND 4"SAN PIPE IN SLAB. 2 PROVIDE 4" FCO. 3 1"CW, 3/4" HW AND 2"V PIPES UP. 4 PROVIDE SH-1 (ADA) AND ALL ASSOCIATED ACCESSORIES. CONNECT 1/2"CW AND HW PIPEING IN WALL TO SHOWER CONTROLS. CONNECT SHOWER TRENCH DRAIN TO 4"SAN PIPE IN SLAB. 5 PROVIDE L-1, 1-1/2" P-TRAP, FAUCET, AND ALL ASSOCIATED ACCESSORIES. CONNECT 1/2"CW AND HW PIPES IN WALL TO FAUCET. CONNECT P-TRAP TO 4" SAN PIPE IN FLOOR AND CONNECT 1-1/2" V PIPE DOWN. 6 PROVIDE 2"V PIPE DN AND CONNECT TO 2"V PIPE IN SLAB. 7 PROVIDE DOUBLE BOWL SINK 'SK-1', 1-1/2" P-TRAP, FAUCET, SINK DISPOSAL 'SD-1', AND ALL ASSOCIATED ACCESSORIES. CONNECT 1/2"CW AND HW PIPES IN WALL TO FAUCET. CONNECT P-TRAP TO 4" SAN PIPE IN FLOOR AND CONNECT 1-1/2" V PIPE DOWN. 8 2" CWS MAIN PIPE UP TO ATTIC SPACE. PROVIDE SHUT OFF AT BASE. 9 PROVIDE 2"V PIPE DN AND CONNECT TO 2"V PIPE IN SLAB. CONNECT 2"V NEAR FLOOR TO 2"V PIPE AS SHOWN AND THEN RUN UP ALONG WALL TO APPROX. 12' AFF. TERMINATE WITH AIR ADMITTANCE VALVE INSIDE OX-BOX MOUNTED TO INTERIOR WALL. FCO M 13 16 FD-1 FD-1 12 1"G TO GENERATOR FD-1 2V" 12 6 FD-1 ED-1 15 6 2V" W/D STACKED 29 2V" 12 NFWHB-1 1/2"TW 19 23 EW-1 18 6 14 3/4"HW 3/4"CW 2"V 13 4 2"V 25 26 CB-1 1 L-1 WC-1 16 PROVIDE 2"V PIPE UP TO MEZANINE/ATTIC. 17 PROVIDE NATURAL GAS PRESSURE REGULATOR, METER, AND ALL ASSOCIATED ACCESSORIES. CONNECT 1-1/4"G PIPE TO INLET OF REGULATOR. PROVIDE AND CONNECT 2"G PIPE TO REGULATOR AND METER. CONNECT 2"G PIPE TO METER OUTLET AND UP SIDE OF BUILDING. 18 PROVIDE WASH MACHINE CONNECTION BOX, WITH TWO 3/4" VALVES WITH WATER HAMMER ARRESTERS EA FOR CW AND HW HOSE CONNECTIONS, 3/4"CW AND HW PIPES UP IN WALL, 2" WASTE CONNECTION, AND ALL ASSOCIATED ACCESSORIES. SEE DETAIL 1 ON DRAWING P502 FOR MORE INFORMATION. 19 PROVIDE WASH MACHINE CONNECTION BOX, WITH TWO 1/2" VALVES WITH WATER HAMMER ARRESTERS EA FOR CW AND HW HOSE CONNECTIONS, 1/2"CW AND HW PIPES UP IN WALL, 2" WASTE CONNECTION DN, AND ALL ASSOCIATED ACCESSORIES. CONNECT 2" WASTE PIPE TO 4" WASTE PIPE IN SLAB. CONNECT 1-1/2"V PIPE DN TO WASTE PIPE. SEE DETAIL 1 ON DRAWING P502 FOR MORE INFORMATION. 20 PROVIDE 3/4" GAS SUPPLY PIPE DN AND CONNECT TO STOVE AND TO MAIN IN MEZZANAINE/ATTIC. 21 PROVIDE SIOUX CHIEF ICE MAKER OUTLET BOX WITH 1/2" CW SUPPLY QUARTER -TURN BALL VALVE AND A 1/2" X 1/4" OD COMPRESSION OUTLET. PROVIDE OUTLET BOX WITH FRAME AND STAINLESS STEEL HOSE FOR CONNECTION TO REFRIGERATOR ICE MAKER. 22 4"FP PIPE UP. REFER TO FP101 DRAWING FOR CONTINUATION. 23 PROVIDE VALVE CONNECTION BOX, WITH TWO 1/2" VALVES WITH WATER HAMMER ARRESTERS EA FOR CW AND HW HOSE CONNECTIONS, 1/2"CW AND HW PIPES UP IN WALL. SEE DETAIL 1 ON DRAWING P502 FOR MORE INFORMATION. 2"V NFWHB-2 SD-1 7 1/2" SK-1 10 1-1/2"V 1/2" PROVIDE NFWHB-1 AND ALL ASSOCIATED ACCESSORIES. CONNECT TO IN WALL 1/2" CW AND HW PIPING. 30 1/2"HW 1/2"CW FCO 5 20 FCO SD-1 6 2 FCO 25 1-1/2"V SH-1 2"V SH-1 2 2 1/2"HW 1/2"CW 1/2" 15 CB-1 52904 NO AR RT H CAROLI NA LOT TE , N . C 9/20/2016 9/9/2016 © 2016 LaBella Associates TOWN OF DAVIDSON 6 4 6 FIRE STATION #2 CB-1 9 CERT. NO. 2"V 26 CB-1 CH C TI ON 5 1/2" PROVIDE SAFETY SHOWER SSH-1, TEMPERED WATER MIXING VALVE, AND ALL ASSOCIATED ACCESSORIES. PROVIDE AND CONNECT 1/2" CW AND HW PIPING TO MIXING VALVE. PROVIDE AND CONNECT 1/2" TEMPERED WATER PIPING TO MIXING VALVE AND SHOWER. G S. BLYT ES OR A 2"V L-1 14 3 WC-1 1-1/2"V PROVIDE 2" SAN W/ DEEP SEAL P-TRAP UP TO DRAIN PAN ON MEZZAININE/ATTIC. ROUTE PIPING TO EXTERIOR WALL DOWN TO SPLASH BLOCK. PROVIDE AIR GAP PER CODE. AR ASS O CI AT I TE C TU R A CH L RP 6 13 G INEER LA O 1 PROVIDE FD-1 AND CONNECT TO 4"SAN PIPE IN SLAB. SEAL 030515 EN AI E S S IO N EL C. 13 12 CR 21 PROVIDE SS-1, 1-1/2" P-TRAP, FAUCET, AND ALL ASSOCIATED ACCESSORIES. CONNECT 1/2"CW AND HW PIPES IN WALL TO FAUCET. CONNECT P-TRAP TO 4" SAN PIPE IN FLOOR AND CONNECT 1-1/2" V PIPE DOWN. OF I P. 11 PROVIDE 1/2" HW PIPE AND CONNECT TO DISHWASHER. PROVIDE WASTE HOSE AND CONNECT FROM DISHWASHER TO SD-1 DISHWASHER TYE-IN POINT. H C ARO L AL 10 T OR NA SSH-1 NC LICENSE NO. C-0430 . LI-1 B MSB-1 LA 28 24 ED 2V" 6 R E GI S TE R 6 2 FCO E 2V" H 2V" 12 L-1 N 2V" 5 PR 2"G UP 9 24 PROVIDE LINT INTERCEPTOR LI-1. SEE P-100 FOR ADDITIONAL INFORMATION. 25 PROVIDE TD-1 AND ALL ASSOCIATED ACCESSORIES. SEE P-100 FOR ADDITIONAL INFORMATION. 26 PROVIDE CB-1 AND ALL ASSOCIATED ACCESSORIES. SEE P-100 FOR ADDITIONAL INFORMATION. 27 1-1/2" CWS TRUCK FILL LINE MOUNT 36" AFF. EXTEND 1-1/2" CWS UP TO ATTIC SPACE CONTINUE ON P-102. COORDINATE CONNECTION WITH FIRE DEPARTMENT AHJ. 2 FCO 28 PROVIDE MOP SERVICE BASIN MSB-1, DRAIN, WALL MOUNTED FAUCET, WITH PAIL HOOK AND ALL ASSOCIATED ACCESSORIES. 29 PROVIDE 4" WASTE AND CONNECT TWO 2" WASTE FROM WASHER BOXES. EXTEND 2" VENT UP VENT SYSTEM IN CEILING. 30 PROVIDE NFWHB-2 AND ALL ASSOCIATED ACCESSORIES. CONNECT TO IN WALL 1/2" CW PIPING. 6 9/20/16 INTERACTIVE REVIEW COMMENTS 5 9/16/16 INTERACTIVE REVIEW COMMENTS 4 9/14/16 INTERACTIVE REVIEW COMMENTS 3 09/07/16 PERMITTING COMMENTS 2 08/15/16 1 08/10/16 NO: DATE: ADDENDUM 2 PERMITTING COMMENTS DESCRIPTION: REVISIONS 25 25 PROJECT NUMBER: DRAWN BY: PAV/DWM REVIEWED BY: BB ISSUED FOR: DATE: DRAWING NAME: FIRE TRUCK FILL CONNECTION 15 NFWHB-1 27 8 22 00/00/0000 00:00AM FLPTH DRAWING NUMBER: MECKLENBURG COUNTY CODE ENFORCEMENT The Design In These Construction Documents Have Been Reviewed For Compliance With The State Building Code. It Is The Responsibility Of The Contractor To Construct This Project With Good Engineering Practice And In Compliance With The North Carolina State Building Code. P-101 11 27 KEY NOTES: 14 WH-2 1 PROVIDE 2" GAS RISER UP FROM GAS REGULATOR. SUPPORT PIPING FROM WALL.. PAINT EXTERIOR PIPING. 2 ROUTE GAS PIPING AS SHOWN IN ATTIC SPACES. PROVIDE HANGERS AND GAS SHUT OFF VALVES AS INDICATED AND REQUIRED BY CODE. 3 PROVIDE 1" GAS DN TO GF-1 WITH DRIP LEG, SHUT OFF VALVE AND REGULATOR. FINAL CONNECTION BY EQUIPMENT INSTALLER. 4 PROVIDE 3/4" GAS DN TO RADIANT HEAT BURNERS, IRH-1 THRU 4 WITH DRIP LEG, SHUT OFF VALVE AND REGULATOR. FINAL CONNECTION BY EQUIPMENT INSTALLER. 5 PROVIDE 3/4" GAS DN TO GAS STOVE IN KITCHEN WITH DRIP LEG, SHUT OFF VALVE AND REGULATOR. FINAL CONNECTION BY EQUIPMENT INSTALLER. 6 PROVIDE 2"V PIPE DN 7 PROVIDE 1" GAS DN TO WH-1 AND WH-2. CONNECT TO WG WITH DRIP LEG AND GAS SHUT OFF VALVE. RUN GAS PIPING ON MEZZANINE WALL. 8 PROVIDE 4" VENT UP THRU ROOF. COORDINATE ROOF PENETRATION AND FLASHING WITH ROOFING INSTALLER. 9 PROVIDE 1/2" CW AND 1/2" HW DN TO DOMESTIC HOSE CONNECTION BOX. PROVIDE ALL ASSOCIATED ACCESSORIES. 10 PROVIDE 2"V PIPE DN AND CONNECT TO 2"V PIPE IN SLAB. 21 2"V HWCP-2 15 1" 13 28 1/2" 1" 2"V 10 20 1"G (210 CFH) 1" WH-1 1"G (210 CFH) 28 16 PROVIDE 1/2" CW AND 1/2" HW, 1-1/2" WASTE PIPE DN TO L-1. RUN BRANCH PIPING IN ATTIC AS SHOWN. 17 PROVIDE 3/4" CW AND 3/2" HW, 2" WASTE PIPE DN TO MSB-1. RUN BRANCH PIPING IN ATTIC AS SHOWN. 18 PROVIDE 3/4" CW AND 3/4" HW DN TO EQUIPMENT WASH MACHINE CONNECTION BOX. PROVIDE ALL ASSOCIATED ACCESSORIES. SEE WASH MACHINE CONNECTION BOX DETAIL FOR MORE INFORMATION. 19 PROVIDE 1/2" CW AND 1/2" HW DN TO DOMESTIC WASH MACHINE CONNECTION BOX. PROVIDE ALL ASSOCIATED ACCESSORIES. SEE WASH MACHINE CONNECTION BOX DETAIL FOR MORE INFORMATION. 20 PROVIDE 1/2"CW AND 1/2" HW DROPS DOWN TO TEMPERED WATER MIXING VALVE SERVING SSH-1. 21 PROVIDE HWCP-2, 1/2" CHECK VALVE, AND ALL ASSOCIATED ACCESSORIES. CONNECT TO 1/2" HWR PIPING. SEE DETAIL 12/P501 FOR MORE INFORMATION. 3/4"G (80 CFH) HWCP-1 22 PROVIDE 1" CW AND 3/4" HW DROPS DN TO PLUMBING EQUIPMENT IN KITCHEN AND MENS AND WOMENS SHOWER ROOMS. 23 PROVIDE 1/2' CW AND 1/2" HW DN AND CONNECT TO NFHB-1. 24 2" CW UP FROM WATER SUPPLY CLOSET. 25 4"FP PIPE UP. REFER TO FP101 DRAWING FOR CONTINUATION 26 PROVIDE 1-1/2" DROP DN TO TRUCK FILL CONNECTION. PROVIDE DOUBLE CHECK VALVE ASSEMBLY ON PIPE DROP. 27 PROVIDE 1/2" CW AND 1/2" HW DROPS DN AND CONNECT TO SH-1 IN LOCKER ROOM. 28 PROVIDE 1/2" BALANCE VALVE, CHECK VALVE, SHUT-OFF VALVE AND ALL ASSOCIATED ACCESSORIES. CONNECT TO 1/2" HW AND HWR PIPING. 29 PROVIDE HWCP-1, 1/2" CHECK VALVE, AND ALL ASSOCIATED ACCESSORIES. CONNECT TO 1/2" HWR PIPING. SEE DETAIL 12/P501 FOR MORE INFORMATION. 30 PROVIDE CONDENSATE DRAIN LINE TO 1" P-TRAP BELOW MEZZANINE FLOOR AND ROUTE TO EXTERIOR WALL. PROVIDE SPLASH BLOCK. CONDENSATE DRAIN LINE BY EQUIPMENT INSTALLER. MAINTAIN AIR GAP PER CODE. 2 1" CD HP-1 3/4"G (40 CFH) 1"G (80 CFH) 4 2" CW RT H CAROLI NA LOT TE , N . C TOWN OF DAVIDSON 216 South Main Street, Davidson, NC 28036 3/4" MECHANICAL PLATFORM --- 1-1/2"G (160 CFH) PROVIDE DRAIN PAN W/ 2" DRAIN FOR WH. CONNECT 2" DRAIN TO 2" P-TRAP BELOW MEZZANAINE FLOOR AND ROUTE TO EXTERIOR WALL. PROVIDE SPLASH BLOCK. PIPING BY EQUIPMENT INSTALLER. MAINTAIN AIR GAP PER CODE. AR © 2016 LaBella Associates 29 1/2" 15 52904 9/14/2016 9/9/2016 1" 7 1" G PROVIDE WH-2 AND CONNECT TO 1" CW AND 1" HW PIPING. PROVIDE MIXING VALVE, T&P RELIEF VALVE, DRAIN PAN AND ALL ASSOCIATED ACCESSORIES PER WATER HEATER DETAIL AND SPECS C CERT. NO. NO CH G S. BLYT ES TI ON 22 14 AR ASS O CI AT I TE C TU R A CH L OR A 13 PROVIDE EXPANSION TANK SIZED FOR WATER HEATER AND INSTALL PER WATER HEATER DETAIL AND SPECS. LA RP 6 5 8 13 G INEER EL O 15 12 3/4"G (40 CFH) AI 2 2"V 4 PROVIDE WH-1 AND CONNECT TO 1" CW AND 1" HW PIPING. PROVIDE MIXING VALVE, T&P RELIEF VALVE, DRAIN PAN AND ALL ASSOCIATED ACCESSORIES PER WATER HEATER DETAIL AND SPECS. E S S IO N SEAL 030515 EN CR 2 12 OF I C. 1" PROVIDE 1/2"CW AND 1/2" HW PIPES DN IN WALL TO FAUCET ON SS-1. DROP 1-1/2" V PIPE DOWN AND CONNECT TO WASTE PIPING. H C ARO L AL 11 T OR P. N 8 NC LICENSE NO. C-0430 NA 1-1/2"G (160 CFH) 19 18 1" . 1/2" B 1"G (210 CFH) 2"G (580 CFH) LA 1" ED 3"V 1" 2 R E GI S TE R 2 9 HP-2 1/2" 17 23 MEZZANINE --- E 2"G (580 CFH) 2"V 16 H 2"G UP (580 CFH) 1" 1"G (130 CFH) 1 www.labellapc.com PR 6 1" CD 7 Engineering Architecture Environmental Planning 455 South Main Street Davidson, NC 28036 P: (704) 439-2931 4 FIRE STATION #2 19436 DAVIDSON CONCORD ROAD, DAVIDSON, NC 28036 4 9/14/16 INTERACTIVE REVIEW COMMENTS 3 09/07/16 PERMITTING COMMENTS 2 08/15/16 1 08/10/16 NO: DATE: ADDENDUM 2 PERMITTING COMMENTS DESCRIPTION: REVISIONS PROJECT NUMBER: 2151374 DRAWN BY: 1/2" PAV/DWM REVIEWED BY: BB ISSUED FOR: CONSTRUCTION DATE: 07.25.16 DRAWING NAME: 4 3/4"G (40CFH) 3/4"G (40CFH) PLUMBING MEZZANINE PLAN 24 4 1-1/2" CWS 1/2" 1/2" CW 1-1/2" 00/00/0000 00:00AM FLPTH 23 26 DRAWING NUMBER: 25 MECKLENBURG COUNTY CODE ENFORCEMENT 1 PLUMBING P102 1/4" = 1'-0" MEZZANINE PLAN N The Design In These Construction Documents Have Been Reviewed For Compliance With The State Building Code. It Is The Responsibility Of The Contractor To Construct This Project With Good Engineering Practice And In Compliance With The North Carolina State Building Code. P-102 Engineering Architecture Environmental Planning 455 South Main Street Davidson, NC 28036 P: (704) 439-2931 www.labellapc.com B ED 52904 AR RT H CAROLI NA C . E TI ON H C CERT. NO. NO CH G S. BLYT ES OR A R E GI S TE R LA AR ASS O CI AT I TE C TU R A CH L RP CR G I N EER LA O SEAL 030515 EN AI E S S IO N EL C. OF I AL PR H CARO L P. O RT NA N NC LICENSE NO. C-0430 L OT TE , N . 9/16/2016 9/9/2016 © 2016 LaBella Associates TOWN OF DAVIDSON 216 South Main Street, Davidson, NC 28036 5 FIRE STATION #2 19436 DAVIDSON CONCORD ROAD, DAVIDSON, NC 28036 5 9/16/16 INTERACTIVE REVIEW COMMENTS 4 9/14/16 INTERACTIVE REVIEW COMMENTS 3 09/07/16 PERMITTING COMMENTS 2 08/15/16 1 08/10/16 NO: DATE: ADDENDUM 2 PERMITTING COMMENTS DESCRIPTION: REVISIONS PROJECT NUMBER: 2151374 DRAWN BY: PAV/DWM REVIEWED BY: BB ISSUED FOR: CONSTRUCTION DATE: 07.25.16 DRAWING NAME: 3 1 PLUMBING RISER DIAGRAM 00/00/0000 00:00AM FLPTH DRAWING NUMBER: MECKLENBURG COUNTY CODE ENFORCEMENT The Design In These Construction Documents Have Been Reviewed For Compliance With The State Building Code. It Is The Responsibility Of The Contractor To Construct This Project With Good Engineering Practice And In Compliance With The North Carolina State Building Code. P-401 INSTALL WATER HAMMER ARRESTOR JUST BEFORE LAST FIXTURE ON BRANCH LINE INSTALL WATER HAMMER ARRESTOR ON ALL FIXTURES WITH QUICK CLOSING VALVES. MEMBRANE CLAMPING COLLAR AND SEEPAGE PAN PROVIDE CLEANOUT TEE WITH SCREWED COUNTERSUNK ABS PLASTIC PLUG. CLEANOUT FACE SHALL BE WITHIN 4" OF WALL SURFACE. PROVE EXTENSION IF REQUIRED 3/4"CW 3/4"HW www.labellapc.com INSTALL AN ADDITIONAL WATER HAMMER ARRESTOR IF THE BRANCH LINE IS GREATER THAN 20' LONG. SINGLE OR DOUBLE FIXTURE Engineering Architecture Environmental Planning 455 South Main Street Davidson, NC 28036 P: (704) 439-2931 LOCKABLE BALL VALVE CONCRETE FLOOR MULTIPLE FIXTURES REDUCING TRAP PDI SIZE MAXIMUM TAILPIECE LENGTH IS 2 FEET SLOPE WASTE AT TWO PERCENT 3/4" 12-32 URINAL 4 -- C 1" 33-60 LAVATORY/SINK 1.5 1.5 D 1-1/4" 61-113 JANITOR'S SINK 3 3 E 1-1/2" 114-154 F 2" 154-330 AR ES C CERT. NO. 52904 NO CH G S. BLYT ASSOCI AT I TE C TU R A CH L R A TI ON G INEER LA PO SAFETY SHOWER AND EYEWASH DETAIL E S S IO N SEAL 030515 EN AI 4 OF EL OR FLOOR LINE H CARO L C. WATER HAMMER ARRESTER DETAIL T OR P. 3 NONE COMBINATION DRENCH SHOWER AND EYE/EYE-FACE WASH BRADLEY MODEL S19-310 NC LICENSE NO. C-0430 AL FLOOR DRAIN AND SINK DETAIL TMV - NAVIGATOR EFX S19-2100 WITH CABINET A COMMENTS: 1. WATER HAMMER ARRESTERS SHALL BE HAVE PISTON AND 0-RING CONSTRUCTION WITH PDI #WH-201, ASSE # 1010 AND ANSI # A112.26.1M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. SIZE THE UNITS AS SHOWN PER THE TABLES SHOWN ABOVE. NONE CHECK VALVES EMERGENCY FACE WASH/EYE B B PULL-ROD HANDLE AT 69" A.F.F. LA -- ED 5 R E GI S TE R VALVE WATER CLOSET E 1-11 IN 2 1/2" H MAXIMUM 8' ON 2" WASTE OR 10' ON 3". A CR WALL CLEANOUT NONE HOT 1" TW COMMENTS: 1. LOCATE FLOOR DRAIN/SINK WHERE SHOWN ON DIMENSIONED FLOOR PLAN. IF SITUATION IS FLOOR SLAB ON GRADE, SET DRAIN BODY IN PLACE, PROVIDE BACKFILL, AND POUR AROUND IT. RECESS TOP OF FLOOR DRAINS 1/2" BELOW FLOOR DATUM AND SLOPE FLOOR TO IT. DO NOT RECESS FLOOR SINKS. 2. OTHER VENTING METHODS MAY BE USED, IF APPROVED BY LOCAL CODE AND/OR LOCAL AUTHORITIES. COMMENTS: PROVIDE WALL CLEANOUT (WCO) WHERE SHOWN ON PLAN AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A FLOOR CLEANOUT. COLD N LONG SWEEP AT END OF LINE OR COMBINATION WYE FIXTURE PR PROVIDE TRAP PRIMER IF REQUIRED BY LOCAL AUTHORITIES OTHERWISE DEEP-SEAL P-TRAP WATER SUPPLY FIXTURE UNIT (WSFU) FIXTURE UNIT LOAD 42" AFF MAXIMUM 12' WHERE ENLARGED 4" WASTE LINE IS USED AS A COMBINATION WASTE AND VENT SYSTEM HUB AT FLOOR PIPE SIZE 33" - 45" A.F.F. PROVIDE A ROUND 18 GAUGE STAINLESS STEEL COVER FOR CONSEALED CLEANOUTS 1 GALVANIZED OR STAINLESS STEEL TO MATCH SAFETY SHOWER EQUIPMENT AR RT H CAROLI NA L OT TE , N . C . 9/9/2016 NONE © 2016 LaBella Associates WALL WATER CLOSET TOP BEAM C-CLAMP IF STEEL BAR JOIST. SEAT ADJUSTABLE BAND HANGER FOR PIPING FOUR INCH OR LESS. CHASE STORM COLLAR PROVIDE COPPER OR NON-METALLIC COATING WHERE HANGERS CONTACT BARE COPPER PIPE. NOTES: C.W. SUPPLY 216 South Main Street, Davidson, NC 28036 STEEL DECK SEAL ALL AROUND DO NOT HANG PIPE LARGER THAN 4" FROM BOTTOM OF JOISTS, AND HANG ONLY AT PANEL POINT. VENT PROVIDE GALVANIZED STEEL SADDLE FOR ALL INSULATED PIPE 1" AND LARGER. VERIFY INSULATION THICKNESS WHEN SIZING HANGERS. DO NOT SUSPEND OTHER ITEMS FROM PIPE. WATER CLOSET FINISHED FLOOR CONCRETE SLAB WATER CLOSET FLOOR FLANGE ESCUTCHEON 4" SAN TO NEAREST MAIN ANCHOR PIPE TO ROOF DECK OR JOISTS WITH U-BOLT AROUND PIPE AND ANGLE IRON WELD- ED OR SCREWED TO DECK OR JOIST ROOF H OPENING IN ROOF FLUSH VALVE HOLDRITE BRACING 4" SAN ELEVATION FL MTD TANK TYPE WATER CLOSET DETAIL NONE COMMENTS: 1. PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES. SLOPE ALL WATER PIPING SLIGHTLY TOWARD DRAINABLE LOCATIONS. HANGER SPACING FOR PIPE SIZE: COPPER: 2"=9' 1 1 2 "=8' 1 1 4 "=7' 1"=6' 3 4 "=6' 3 4 "=5'. CAST IRON: 10' AND ONE NEAR ALL JOINTS. STEEL: 3"=12' 2 1 2 "=11' 2"=10' 1 1 2 "=9' 1"=7' 3 4 "=6' 1 2 "=5'. LOCATE HANGERS AS CLOSE AS POSSIBLE TO TURNS AND TEES OF PIPE. PROVIDE SUPPLEMENTARY STEEL STRUTS BETWEEN JOISTS IF REQUIRED. LOCATE HANGERS TO TAKE LOAD OFF OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY. PROVIDE SEISMIC BRACING AS REQUIRED BY LOCAL AUTHORITIES. CHAINS OR PERFORATED STRAP IRON OR STEEL IS NOT ACCEPTABLE. DO NOT SUSPEND PIPE FROM JOIST BRACING MEMBERS. REFER TO CODES AND SPECIFICATIONS FOR FURTHER INFORMATION. 6 CW (IN) BALL VALVE (TYP.) FLASHING BY ROOFING CONTRACTOR HUBLESS PIPE CONNECTORS ON CAST IRON PIPE. PROVIDE PIPE INCREASER WHERE REQUIRED TO MAKE MINIMUM 3" VENT THRU ROOF SEAT KHW 140°F (IN) FLASHING SKIRT CLEVIS HANGER FOR PIPE OVER FOUR INCH. 1. FOR CONTINUATION OF PIPING SEE PLANS. 2. MINIMUM CHASE SPACE SHOWN MUST BE CLEAR SPACE. PLAN VIEW 2'-0" MIN. VENT 5 TOWN OF DAVIDSON ALL-THREAD ROD. LENGTH AS REQ'D FOR PIPE SLOPE. M COMMENTS: 1. REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. 2. 7 NONE WATTS MMV ASSE 1070 MIXING VALVE WITH TEMPERATURE ADJUSTMENT UNION (TYP.) LOCATE VTR MINIMUM THREE FEET FROM PROPERTY LINE, OR TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, OR ONE FOOT FROM ANY VERTICAL SURFACE. 3. PIPE HANGER DETAIL C FIRE STATION #2 TW 110°F (OUT) LOCATE VTR MINIMUM 18" FROM PARAPET, EXPANSION JOINT, EQUIPMENT CURB, ETC. OFFSET IN CEILING SPACE WHERE REQUIRED TO MEET THESE CONDITIONS. VENT THRU ROOF (VTR) DETAIL NONE 8 THEMOSTATIC MIXING VALVE NONE PIPING HANGER SUPPORTS GAS BRANCH TO EQUIPMENT EXTEND 1/2" HW, 1/2" CW AND 1-1/2" VENT ABOVE CEILING AND CONNECT TO NEAREST ACTIVE MAIN. CONNECT VENT SYSTEM ABOVE CEILING 1-1/2" CONTINUOUSLY WELDED WATER STOP & ANCHOR COLLAR, WATERPROOF FLOORS ONLY. MIN. 1" ALL OTHERS TO HAVE ANCHOR LUGS (MIN. 3 REQ'D). WATERPROOF CAULK LAVATORY SUPPORT FOR CONCEALED ARM 1/2" HW PIPE SLEEVE PIPE INSULATION (WHERE REQ'D) 6" LAVATORY 1-1/2" P-TRAP 1-1/2" STOP VALVE TYP. CUT OPENING IN EXISTING PRESSURE INJECT EPOXY GROUT TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE AND WALL . SEE SPECIFICATION 030130 MAINTENANCE OF CONCRETE. P-TRAP W/CO 1-1/2" 00/00/0000 00:00AM FLPTH FLOOR PRESSURE INJECT EPOXY GROUT TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE AND WALL . SEE SPECIFICATION 030130 MAINTENANCE OF CONCRETE. NONE LAVATORY DETAIL NONE TYPICAL PIPE SLEEVE THROUGH FLOOR DETAIL The Design In These Construction Documents Have Been Reviewed For Compliance With The State Building Code. It Is The Responsibility Of The NONE Contractor To Construct This Project With Good Engineering Practice And In Compliance With The North Carolina State Building Code. 11 COUNTERTOP SINK DETAIL 1 08/10/16 NO: DATE: PERMITTING COMMENTS ADDENDUM 2 PERMITTING COMMENTS DESCRIPTION: DRAWN BY: T & P VALVE REVIEWED BY: SHUT OFF VALVE (TYPICAL) ISSUED FOR: PAV/DWM BB CONSTRUCTION UNION (TYPICAL) WASTE LINE FROM SINK DATE: MANUAL SHUT-OFF VALVE ( GAS COCK) WITH AN 1/8" N.P.T. PLUGGED TAPPING ACCESSIBLE FOR TEST GAGE CONNECTION TO BE INSTALLED UPSTREAM OF THE GAS SUPPLY CONNECTION TO THE APPLIANCE MEZZANINE FLOOR GROUND JOINT UNION COMMENTS: 1. PIPING SHOWN IS SCHEMATIC. PROVIDE CLEARANCES RECOMMENDED BY MANUFACTURER. PROVIDE SEISMIC STRAPPING AS REQUIRED. 2. SET THERMOSTAT AT 130°F. 12 NONE WATER HEATER DETAIL 07.25.16 DRAWING NAME: WH-1 DRAIN VALVE 6" DRIP LEG WITH CAP EXTEND 1/2" HW, 1/2" CW AND 1-1/2" VENT ABOVE CEILING AND CONNECT TO NEAREST ACTIVE MAIN. MECKLENBURG COUNTY CODE ENFORCEMENT 10 1-1/2" FIRE RESISTANT SILICONE FOAM SEALER CONNECT WASTE PIPING TO SANITARY MAIN BELOW FLOOR 9 1/2" CW WASTE LATERIAL CONCRETE FLOOR SLAB 08/15/16 2151374 EXPANSION TANK 1-1/4" METAL DECK PROVIDE CONNECTION TO DOMESTIC HOT & COLD WATER AND HOT WATER RECIRCULATION PIPING. SINK CUT OPENING IN EXISTING 09/07/16 2 PROJECT NUMBER: THERMOMETER (TYPICAL) VENT LINE FROM SINK CABINET 3 REVISIONS BALANCING VALVE (TYPICAL) 1/2" CW STOP VALVE TYP. HOT WATER RECIRCULATING PUMP G 1/2" HW G PIPE WALL V WALL 19436 DAVIDSON CONCORD ROAD, DAVIDSON, NC 28036 3 DRAIN PAN 2" WASTE 1 PLUMBING DETAILS ROUTE TO EXTERIOR WALL P-TRAP DRAWING NUMBER: P-501 WASHING MACHINE BOX (WMF-X) 2 2 1 " TEMPERED(T) WATER FROM SHOWER SH-1(ADA). EXTEND 2 MIXING VALVE TO SHOWER HAND HELD SPRAY SYSTEM WITH VACUUM BREAKER AND 60" HOSE. RUN PIPING IN WALL CHASE AND ABOVE CEILING. 1 1-1/2" VENT 4 1/2" 1/2" 2 DROP12" H&C WATER DN TO TEMPERATURE CONTROL MIXING VALVE. RUN PIPING IN WALL CHASE. 3 THERMOSTATIC TEMPERING VALVE SERVING SHOWER 1 " TEMPERED WATER TO HAND HELD SH-2(ADA). CONNECT 2 SHOWER AND TO DIVERTER VALVE AND SHOWER HEAD. 1 1/2" 1/2" INLET C.O. INLET 3" NG GAS TO GAS PRESSURE BOOSTER SYSTEM OIL SEPARATOR 3" NG TO BUILDING 5 SHOWER FLOOR DRAIN. MAIN SHUT-OFF VALVE 6 2" VENT PIPE RUN TO NEAREST WALL AND UP TO VENT SYSTEM IN CEILING. EQUIPMENT PAD SEE DETAIL 4" 12" MIN. DIRT LEG GAS METER 3" OUTLET CR EN AI 1 2 WASHING MACHINE BOX DETAIL NONE 3 ADA SHOWER DETAIL NONE 4 GAS METER DETAIL NONE G INEER G S. BL B LA L ES C CERT. NO. 52904 NO CH YT I TE C TU R A R ATI ON 3" P-TRAP SEAL 030515 A ASSOCI AT H RC PO FINISHED FLOOR E S S IO N LA OR 3" SANITARY PIPE OF EL C. GAS METER AND REGULATOR SHALL BE BY THE LOCAL GAS COMPANY. H CARO L I ED 2" VENT PIPE T OR P. NOTES: AL 7 NC LICENSE NO. C-0430 RUN VENTS BELOW GRADE TO BUILDING WALL. EXTEND UP WALL TO ABOVE ROOF AND ANCHOR VENTS SECURELY TO WALL. NA 6 G R E GI S T E R 5 OIL STORAGE VENT NOTE: E 2" WASTE GAS MAIN BY GAS COMPANY 3" WASTE PIPING. EXTEND PIPING TO NEAREST MAIN. PITCH TO DRAIN MIN 1/8" PER FT. 7 SEPARATOR VENT 3" N 2" TRAP AND WASTE PIPE www.labellapc.com GRADE 48" 42" AFF GENERATOR SHUT-OFF VALVE, LABELED IN ACCORDANCE WITH NFPA 110 PRESSURE REGULATOR UNION (TYPICAL) 3 4" CAPPED TEST TEE SHOWER HEAD. EXTEND 1/2" CW FROM DIVERTER VALVE TO SHOWER HEAD PIPING TO BE CONCEALED IN WALL CHASE. 4 HWS 72" CWS EXTENSION UP TO GRADE PR HOSE VALVE CONNECTION CW HW(125) NOTES: H WATER HAMMER ARRESTOR (WHA-X) Engineering Architecture Environmental Planning 455 South Main Street Davidson, NC 28036 P: (704) 439-2931 AR RT H CAROLI NA L OT T E , N . C . 07/25/16 OIL SEPARATOR DETAIL NONE © 2016 LaBella Associates TOWN OF DAVIDSON P&G CHEMICAL DISPENSER FLOOR SLAB ON GRADE MEMBRANE CLAMP AS REQUIRED FOR DEPTH OF SEWER P&G CHEMICAL BOTTLE HW AND CW ISOLATION VALVES HW AND CW PIPING (RUN BESIDE EACH OTHER IN WALL) SAME SIZE AS SEWER UP TO 4" MAXIMUM. FAUCET AND VALVES JANITOR'S SINK LONG SWEEP ELBOW AT END OR TURN OF RUN. HUB AND SPIGOT CAST IRON PIPE BELOW FLOOR. FIAT FAUCETS MODEL 830-AA COMBINATION WYE AND EIGHTH BEND IN RUN. ENTER TOP OF PIPE. SANITARY SEWER LINE FINISHED FLOOR DIRECTION OF FLOW COMMENTS: 1. EACH CHEMICAL DISPENSER MUST HAVE A DEDICATED WATER SUPPLY, LOCATED WITHIN 4 FEET OF THE DISPENSER. IT MUST PROVIDE TEMPERED WATER (ADJUSTABLE FROM 60-120F) WITH A FLOW RATE OF 4 GPM AT 40 PSI DYNAMIC/FLOWING PRESSURE (35 PSID MIN.). THE HOT AND COLD WATER SUPPLY LINES MUST HAVE CHECK VALVES TO PREVENT HOT/COLD WATER CROSSOVER, IF THE TEMPERING VALVE DOES NOT INCLUDE THEM. IT MUST INCLUDE A SHUTOFF VALVE TERMINATING IN A 43 " GARDEN HOSE MALE FITTING. MOP SINK MS-1 COMMENTS: 1. LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 50' INTERVALS ON STRAIGHT RUNS, AND/OR WHERE SHOWN ON PLANS. PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. FINISHED FLOOR TO VENT MAIN. 2" VENT PIPING 2. ROUND SECURED GASKETED NICKEL BRONZE ADJUSTABLE TOP WITH "CO" CAST IN COVER. PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS). PROVIDE GASKETED PLASTIC PLUG IN CAST IRON BODY. USE TEFLON JOINT COMPOUND ON PLUG THREADS. CLEAN THE TOP OF EXPOSED FCO AFTER INSTALLATION. 5 6 NONE NONE 7 FLOOR CLEANOUT DETAIL NONE 4" CW OPTIONAL WATER FEED FROM ABOVE 00/00/0000 00:00AM NO: DATE: DRAWN BY: BUILDING EXTERIOR -DESCRIPTION: REVIEWED BY: OPERATING ROD AND CASING LENGTH = WALL DEPTH + 2" ACCESS PANEL LOCATION BASED ON PIPE FEED 3 HOSE CONNECTION 4" NOTES: 1. 2. 3. 4" CW OPTIONAL WATER FEED FROM ABOVE GRADE 4. 5. 4" UNION COMPRESSOR AND TANK BB ISSUED FOR: CONSTRUCTION DATE: 07.25.16 DRAWING NAME: 24" MIN EXPOSED PIPE SHALL HAVE ESCUTCHEON TO COVER PENETRATION. SAFETY VALVE FLEXIBLE CONNECTION PRESSURE RELIEF VALVE SET FOR 50 P.S.I. W/PRESSURE GAUGE WALL BOX UNION SHUTOFF VALVE 3 PAV/DWM 10" 10" 3 FLPTH -- 2151374 BUILDING INTERIOR 6. 7. I.P.S. COMMENTS: 1. CENTER PIPE ALONG WITH THE INSULATION IN SLEEVE. CONTINUE THE INSULATION THRU THE SLEEVE. NONE -- THICKNESS WALL BOX PIPE PENETRATION (NON-RATED WALL) PAVEMENT PER DESIGN DOCUMENTS REVISIONS INSULATED PIPE 9 EXPANSION JOINT TO ENGINEER'S DETAILS SEE NOTE 3 PROJECT NUMBER: 3 UNINSULATED PIPE PROVIDE GALVANIZED STEEL PIPE SLEEVE GROUTED INTO WALL. CHEMICAL SYSTEM AT JANITOR'S SINK WALL PIPE OR CONDUIT WALL CONSTRUCTION: PRE-CAST, POURED IN PLACE OR MASONRY BLOCK 19436 DAVIDSON CONCORD ROAD, DAVIDSON, NC 28036 NONE 10" STUD AND GYPSUM WALLBOARD CONSTRUCTION: PROVIDE GALVANIZED STEEL PIPE OR MINIMUM 18 GA GALVANIZED SHEET METAL SLEEVE. CAULK OR GROUT SLEEVE IN PLACE AS REQUIRED. 8 MOP SINK DETAIL FIRE STATION #2 2. THE DEDICATED WATER SUPPLY SHOULD NOT HAVE ANY BACKFLOW PREVENTION (E.G. NO ATMOSPHERIC VACUUM BREAKER, ETC.), UNLESS REQUIRED BY THE LOCAL PLUMBING CODE OR UTILITY- EACH CHEMICAL DISPENSER INCLUDES AN INTEGRAL BACKFLOW PREVENTOR ASSE 1055) TO SANITARY MAIN. 3" SANITARY PIPING SEE NOTE 4 PACK ANNULAR SPACE SOLID WITH FIBERGLASS INSULATION (FOR ACOUSTICS). 216 South Main Street, Davidson, NC 28036 IT IS NECESSARY TO ENSURE MINIMUM DIMENSIONS SHOWN ARE SUITABLE FOR EXISTING GROUND CONDITIONS. ENGINEERING ADVICE MAY BE REQUIRED. MINIMUM CONCRETE STRENGTH OF 4,000 PSI IS RECOMMENDED. CONCRETE SHOULD BE VIBRATED TO ELIMINATE AIR POCKETS. EXPANSION AND CONTRACTION CONTROL JOINTS AND REINFORCEMENT ARE RECOMMENDED TO PROTECT CHANNEL AND CONCRETE SURROUND. ENGINEERING ADVICE MAY BE REQUIRED. THE FINISHED LEVEL OF THE CONCRETE SURROUND MUST BE APPROX. 1/8" [3mm] ABOVE THE TOP OF THE CHANNEL EDGE. CONCRETE BASE THICKNESS SHOULD MATCH SLAB THICKNESS. ENGINEERING ADVICE MAY BE REQUIRED TO DETERMINE PROPER LOAD CLASS. REFER TO ACO'S LATEST INSTALLATION INSTRUCTIONS FOR FURTHER DETAILS. S200k - POWER DRAIN - LOAD CLASS: E TO COMPRESSED AIR LOOP VIBRATION ISOLATORS (TYP. FOR 4) MOISTURE AND OIL SEPARATOR DRAIN TO OUTSIDE OF BLDG. FINISHED FLOOR PLUMBING DETAILS GATE VALVE DRAWING NUMBER: MECKLENBURG COUNTY CODE ENFORCEMENT 10 NONE FREEZE PROOF WALL HYDRANT DETAIL 11 NONE The Design In These Construction Documents Have Been Reviewed For Compliance With The State Building Code. It Is The Responsibility Of The Contractor To Construct This Project With Good Engineering Practice And In Compliance With The North Carolina State Building Code. TRENCH DRAIN DETAIL S200K POWERDRAIN 12 NONE AIR COMPRESSOR DETAIL P-502 L-1 LAVATORY YES KOHLER LEDENA K-2215 ADA 21" X 116-1/4" SK-1 SINK - COUNTER TOP DROP-IN YES KOHLER TOCCATA K-3346-4 FLOOR DRAIN - JOSAM WCO WALL CLEAN-OUT - JOSAM MSB-1 MOP SINK YES FIAT TERRAZZO MOP SERVICE BASIN TSBC6010 YES FIAT MODEL LTD II WALL HUNG SERV-A-SINK SS-1 JOSAM 57000 FROST PROOF HOSE BIB YES WOODFORD MB65-K TP-1 TRAP PRIMER YES PRECISION P1-500 EYE WASH TD-1 EYE WASH TRENCH DRAIN SYSTEM YES YES BRADLEY S19314 SERIES ACO DRAIN S200K, SK2-1:SK2-11 CB-1 CATCH BASIN ---- ACO DRAIN CATCH BASIN SK2-621D LI-1 LINT INTERCEPTOR ---- JOSAM MODEL 61806 SD-1 SINK DISPOSAL --- GENERAL ELECTRIC KITCHEN AID WASTE KING INSINKERATOR PR5O XL C.W. H.W. WH-1 WH-2 LOCATION MECHANICAL PLATFORM TRUCK MEZZANINE MANUFACTURER AND MODEL RHEEM GHE80ES-130(A) RHEEM GHE80ES-130(A) WATER CONNECTIONS GAS INPUT (BTUH) 2" 130,000 130,000 2" THERM. EFF. 95% 95% MOUNTING FLUSH TANK VITREOUS CHINA HANDICAP ELONGATED - - - - FLOOR MTD 4" 2 1/2" - KOHLER K-7637-CP FLOOR UNDERCOUNTER VITREOUS CHINA RECTANGULAR BASIN KOHLER DM FAUCET K-13467 STANDARD SENSOR SINGLE-HOLE GRID 1-1/2" 1-1/2" 1/2" 1/2" KOHLER K-8998 P-TRAP, K-7129 DRAIN DROP-IN DOUBLE COMPT. STAINLESS 6" DEEP 2-HOLE KOHLER CORALAIS K-15889-K GOOSENECK DOUBLE LEVER 8" GRID 1-1/2" 1-1/2" 1/2" 1/2" SURROUND ENCLOSURE W/BASE FIBERGLASS W./SANITARY GELCOAT HANDICAP SHOWER PACKAGE K-10825-4 DEVONSHIRE SHOWERING PACKAGE K-10591 MULTIFUNCTI ON SHOWER HEAD SINGLE LEVER K-304/K-P304 SERIES VALVE ROUND TOP CAST IRON BRASS TOP - - - - - CAST IRON - - - - MOP SINK TERRAZZO WITH PAIL HOOK FOUR ARM SWING SPOUT CP BLADE HANDLES 4" - - DOUBLE BOWL LAUNDRY SINK MOLDED STONE ROUND TOP CAST IRON FLOOR MOUNTED FIAT 830-AA FAUCET MOP BASIN WALL HUNG CABINET MOUNTED FIAT A1 4" FAUCET BRONZE PLUG - INTERGRAL WALL-MOUNT FRONT WITH SLIDE TRENCH BAR & HOSE DRAIN W/.75 l-BAR-I GRATE 1/2" 1/2" CAST IRON SEE PLAN - - - - FLOOR PROVIDE: SEDIMENT BUCKET, TRAP PRIMER CONNECTION & VALVE - - 4" - - - - WALL - 8" GRID 3" 2 1/2" 1/2" - FLOOR INCLUDES STRAINER AND PLUG, CSA APPROVED. PROVIDE WITH 832-AA HOSE BRACKET, 889-CC MOP HANGER AND E-77-A GUARD. - 1/2" 1/2" FLOOR WALL MOUNTED STYLE - CABINET MOUNTED WITH , INCLUDES STRAINERS AND PLUGS. 2" - - CAST IRON 4" - - - - KEY CYLINDER LOCK - - - - - 1/2 " - - WALL - BRASS - - - - - - - - 1/2 " - - - FLOOR MOUNTED EYE/FACE WASHDOWN INFLOOR W/EXTENSION UNDER SINK STAINLESS - - POWER DRAIN - - - - - - - 4" 2 TRENCH 4" 1 2 - - - - - HWCP-1 HWCP-2 DOM HW RECIRCULATION DOM HW RECIRCULATION LOCATION MANUFACTURER/MODEL MECHANICAL PLATFORM TACO 4PC80/0012-F4-1 MEZZANINE TACO 4PC8/0012-F4-1 HOUSING MATERIAL BRONZE -LEAD FREE BRONZE-LEAD FREE FLOOR - - - - - CATCH BASIN 4" 2 - - PROVIDE FOUL AIR TRAP GRAVITY DRAIN - - - - - 4" 3" (2 REQ.) - - - - SINK MOUNTED W/DISH WASHER DRAIN 1-1/2" 1-1/2" - - 1-1/2" TRAP MULTI GRIND COMMENTS 170 INSTALL PER MANUFACTURER'S RECOMMENDATIONS 170 INSTALL PER MANUFACTURER'S RECOMMENDATIONS - - - FIXTURE 48 48 VOLTS/PHASE/HZ 115/1/60 115/1/60 HP QTY. SIZE GPH KITCHEN SINK 1 5 GPH 5 MOP SINK 1 10 GPH 10 SHOWER 2 30 GPH 60 LAVATORY 2 5 GPH 10 1/8 1/8 FIXTURE INSTALL PER MANUFACTURER'S RECOMMENDATIONS INSTALL PER MANUFACTURERS RECOMMENDATIONS SIZE GPH SERVICE SINK 1 5 GPH 5 MOP SINK 1 10 GPH 10 SHOWER 1 30 GPH 30 DOMESTIC WASHER 1 30 GPH 30 EQUIPMENT WASHER 1 30 GPH 30 LAVATORY 1 5 GPH 5 TOTAL REQUIRED FLOW AT 70°F TEMPERATURE RISE = OF ASSE 1011 SINGLE CHECK ANTI-SIPHON VACUUM BREAKER, MODULAR BOX SYSTEM PISTON OPERATED, WILL PRIME 1 TO 4 FLOOR DRAINS, DISTRIBUTION UNIT DU-4/DU-U, INSTALL PER MANUFACTURERS RECOMMENDATIONS. SEAL 030515 EN AI E S S IO N G INEER G S. BL EL LA A I TE C TU R A L ES C CERT. NO. 52904 NO CH YT ASSOCI AT H RC AR RT H CAROLI NA L OT T E , N . C . 07/25/16 STANDARD DRAIN HEIGHT, 316 STAINLESS STEEL HANDLE, ANTI-FREEZE VALVE, HALO EYE/FACE WASH, PROVIDE NAVIGATOR S19-2100 EFX25 EMERGENCY THERMOSTATIC MIXING VALVE FOR TEPID WATER. © 2016 LaBella Associates TOWN OF DAVIDSON 216 South Main Street, Davidson, NC 28036 FOOD WASTE DISPOSER SHALL BE INSINKERATOR MODEL PRO EXCEL W/MULTIGRIND PLUS AND SOUNDSEAL UNDER SINK PLUS TECHNOLOGIES, 1.0 HP MOTOR, AUTO-REVERSE GRIND SYSTEM FEATURE, STAINLESS STEEL GRIND CHAMBER AND COMPONENTS. 1.0 HP/120V/60 HZ SHOCK ABSORBER SCHEDULE TAG MANUFACTURER MODEL FIXTURE UNITS INLET SIZE SA-1 JAY R. SMITH HYDROTOLS - 5005 1-11 3/4" SA-2 JAY R. SMITH HYDROTOLS - 5010 12-32 1" SA-3 JAY R. SMITH HYDROTOLS - 5020 33-60 1" SA-4 JAY R. SMITH HYDROTOLS - 5030 61-113 1" SA-5 JAY R. SMITH HYDROTOLS - 5040 114-154 1" SA-6 JAY R. SMITH HYDROTOLS - 5050 155-330 1" 85 QTY. COMMENTS H CARO L I RECESSED IN PROVIDE JOSAM 61806 SERIES LINT INTERCEPTOR W/ACID RESISTANT COATING, NON-SKID COVER, GALVANIZED STEEL BUCKET W/SS SCREENS. PROVIDE WITH EXTENSION AS NEEDED. FLOOR- TRUCK BAY TANK WATER HEATER FLOW CALCULATIONS MAX GPM @ HEAD T OR PROVIDE WITH WATER TIGHT ABS PLUG RECESSED IN PROVIDE GRATE, FOUL AIR TRAP, DEBRIS STRAINER, INSTALLATION DEVICE, GRATE REMOVAL TOOL, GRATE SHALL BE IRON SLOTTED LONGITUDINAL, MODEL 72263 LOAD CLASS: E FLOOR LIVING AREA TANK WATER HEATER FLOW CALCULATIONS GPH DELIVERED @ 90 DEG F RISE NC LICENSE NO. C-0430 PROVIDE CLOSING CAP PART NUMBER 96823, IRON SLOTTED LONGITUDINAL GRATE ADA COMPLIANT, SECURED RECESSED IN POWER LOK LOCKING OR APPROVED EQUAL. INSTALL TRENCH DRAIN SYSTEM PER MANUFACTURERS FLOOR RECOMMENDATIONS. POWER DRAIN PUMP SCHEDULE SERVICE FLOOR - TOTAL REQUIRED FLOW AT 70°F TEMPERATURE RISE = TAG WALL 2" - RECESSED IN FLOOR ADA COMPLIANT, DOUBLE COMPARTMENT, INCLUDES INSTALLATION HARDWARE, TOP - MOUNT. PROVIDE K-15850-4M LEVER HANDLES WITH 1030920 SIDE SPRAY. SEE SD-1 ON SCHEDULE FOR DSPOSAL 3" GRID www.labellapc.com 0.5 GPM MAXIMUM FLOW-RATE, INCLUDES TWO AAA BATTERIES. PROVIDE 1139288 SPRAY AERATED. ADA COMPLIANT, PROVIDE WITH TRUEBRO LAV GUARD UNDERSINK PIPING COVER MODEL #102 E-Z REINFORCED POLYESTER RESIN SURROUND SHOWER ENCLOSURE AND BASE WITH GEL COAT, INTEGRAL FRONT TRENCH DRAIN AND GRATE, HDPE FOLD-UP SEAT CURTAIN ROD, HORIZONTAL AND VERTICAL GRAB BARS, KOHLER ADA SHOWER SYSTEM WITH HAND HELD SHOWER ASSEMBLY W/SLIDE ABR, VACUUM BREAKER &60" HOSE. (ADA/ANSI). INSTALL PER OWNER RECOMMENDATIONS. CHROME RECESSED IN FLOOR TWO PIECE, K-4199 ELONGATED BOWL, K-4467-RZ TOILET FLUSH TANK, K-4731-C TOILET SEAT, 3/8" NPT ANGLE SUPPLY WITH STOP AND ANNEALED VERTICLE TUBEBATTERIES. HIGH EFFICIENCY TOILET 1.28 GPF. ADA COMPLIANT MCGUIRE 175LK & PW8090 COUNTER TOP - POLYESTER POLYMER CONCRETE POLYESTER POLYMER CONCRETE STEEL w/ACID RESISTANT COATING REMARKS KOHLER K-304-CS VALE WITH STOPS GAS HOT WATER HEATER SCHEDULE TAG SUPPLIES & STOPS CR FPHB VENT R ATI ON YES SIZE PO FLOOR CLEAN OUT TYPE AL FCO UTILITY SINK JAY R. SMITH WADE-TYLER ZURN JAY R. SMITH WADE-TYLER ZURN ACORN TERRAZZO WARE MUSTEE SWAN STONE ACORN TERRAZZO WARE MUSTEE SWANSTONE JAY R. SMITH WADE-TYLER ZURN JAY R. SMITH WADE-TYLER ZURN JAY R. SMITH WADE-TYLER ZURN ACORN SAFETY SHOWERS JAY R. SMITH GUARDIAN EQUIPMENT JAY R. SMITH ABT INC MCNICHOLS INDUSTRIES JAY R. SMITH ABT INC MCNICHOLS INDUSTRIES JAY R. SMITH WADE-TYLER ZURN CENTERS OR FD HANDLES C. YES SPOUT P. SHOWER AQUA BATH AQUARIUS BATHWARE BEST BATH SYSTEMS MANUFACTURER MODEL NO. NA SH-1 COMFORT DESIGNS MODEL# XST 3838 TR RRF .75 L-BAR-I AMERICAN STANDARD GERBER ZURN AMERICAN STANDARD GERBER ZURN ADVANCE TABCO ELKAY JUST PIPING CONNECTIONS DRAIN B KOHLER HIGHLINE K-3999-RZ-0 FLOOR MTD TANK TYPE STYLE LA YES MATERIAL ED WATER CLOSET TYPE R E GI S T E R P-1 FAUCET/VALVE OR APPROVED EQUAL BY ONE OF THE FOLLOWING MANUFACTURERS E DESIGN MANUFACTURER & MODEL H ACCESSIBLE N DESCRIPTION PR FIXTURE Engineering Architecture Environmental Planning 455 South Main Street Davidson, NC 28036 P: (704) 439-2931 PLUMBING FIXTURE SCHEDULE FIRE STATION #2 19436 DAVIDSON CONCORD ROAD, DAVIDSON, NC 28036 110 -- -- NO: DATE: -DESCRIPTION: REVISIONS PROJECT NUMBER: 2151374 DRAWN BY: PAV/DWM REVIEWED BY: BB ISSUED FOR: CONSTRUCTION DATE: 07.25.16 DRAWING NAME: PLUMBING SCHEDULES DRAWING NUMBER: 00/00/0000 00:00AM FLPTH MECKLENBURG COUNTY CODE ENFORCEMENT The Design In These Construction Documents Have Been Reviewed For Compliance With The State Building Code. It Is The Responsibility Of The Contractor To Construct This Project With Good Engineering Practice And In Compliance With The North Carolina State Building Code. P-601
advertisement