BFT CellCOM+ 1.2.3 cellular intercom Installation & user manual
Below you will find brief information for cellular intercom CellCOM+ 1.2.3. The CellCOM+ 1.2.3 is a cellular intercom system that can be used to control gates and doors. It features a keypad for access control, a built-in speaker and microphone for two-way communication, and a GSM module for remote control. It also supports caller ID access control, allowing you to program up to 100 numbers to have access. You can also control the intercom using SMS commands, and an optional app (CELL BOX PLUS) for iOS and Android devices provides additional features.
Advertisement
Advertisement
Installation & User Manual For CellCOM+ Cellular Intercom System Product Version 1.2.3 BFT Americas 6100 Broken Sound Parkway N.W. Suite 14, Boca Raton, FL 33487 www.bft-usa.com Toll Free: 877-995-8155 Office: 561-995-8155 Fax: 561-995-8160 P a g e |1 Contents Overview of system Site Survey SIM card Power Call Box Overview Mounting Inserting the SIM Card Connections on GSM Controller Keypad Connections Connecting to Gate controller Other Wiring Tips Powering Up Programming GSM unit GSM unit complete list of Parameters Keypad Overview Basic Keypad Programming Full Keypad Programming Using the Keypad Using the Intercom Control by SMS Check if Gate Open/Closed Using Optional App Setting up the App on iphone Setting up the App on Android Maintenance Troubleshooting P a g e |2 …………….Pg 3 …………….Pg 3 …………….Pg 3 …………….Pg3 …………….Pg 4 …………….Pg 4 …………….Pg 4 …………….Pg5 …………….Pg 5 …………….Pg6 …………….Pg 6 …………….Pg 6 …………….Pg 7 …………….Pg 9 …………….Pg 10 …………….Pg 10 …………….Pg 10 …………….Pg 12 …………….Pg 12 …………….Pg 13 …………….Pg 13 …………….Pg 13 …………….Pg 14 …………….Pg 15 …………….Pg 15 …………….Pg 16 Overview of System Please read this entire manual before attempting to install this system. This system should only be installed by a professional automatic gate installer or access control specialist dealer. It is recommended that the system be set up, configured, commissioned and tested on a workshop bench before taken to site for installation. Site Survey Before installing this system, you need to be sure that there is good mobile GSM cell coverage in the area it is to be installed. It is recommended that you conduct a site survey, and check reception on the site for a GSM network. If reception is poor in the area, then this system is not recommended. This unit can operate on At&T and T-Mobile networks in the USA. SIM Card You will need a SIM card in order to use this system. It should be a regular voice and SMS text SIM card. Do not use a data only SIM, as this is only for tablets and will not work in the unit. 1) Ensure the SIM has calling credit, and can make and receive calls on a cell phone. 2) Check that the SIM is not locked to a phone and can be used in other devices. Call the service provider to unlock it if required. 3) Check that the SIM does not have a PIN code request. 4) You are now ready to begin programming. Power This system comes with a 15v d.c. power supply. It is recommended that it is located within 25 feet of the intercom and cabled in 14 gauge cable. Site Cabling Inside Power Connection Please note: If using 24v dc solar operator power, switch jumper below to 24v position BEFORE turning on power. Surge protector strip 15v dc 3amp power supply Power Board Call box 400mA quick blow fuse Keypad Module Fuse (Red = +15v) 15V l 0V 14 Gauge Power cable 25 feet max 15v 24v IMPORTANT: Voltage selector pin. Switch to use 24v dc solar operator power 15v DC Power in HERE Note: Fit surge protector strip to keep warranty intact. Note: The power board supplies filtered power to the keypad and cellular module, and has surge protection plus a fuse. In the event of a power surge or lightning surge, the fuse is designed to blow and help protect the equipment. P a g e |3 Call Box Overview Microphone Puck antenna Keypad (programmed & wired independently) Speaker grill IMPORTANT Note the location of button numbers 1-10. This is relevant when programming phone numbers. Dual security key locks Illuminated call buttons Note: The nameplate holders are blank, so that the resident’s names can be written on with marker, or transparent label tape lettering. Do not use washable ink. Mounting 5/16 (M8) bolts 3" hole centres Hinge front door 3" hole centres Wall mount Hinge front door Gooseneck mount Inserting the SIM card Note: This unit is a dual 2G/3G system, operating on either 2G or 3G network frequencies of 850/900/1800/1900MHz. close open 1) 2) 3) 4) 5) P a g e |4 Please ensure the SIM card a regular voice SIM card with SMS, from either At&T or T-Mobile. Do not use a data SIM as these are only for tablets. Put the SIM into a phone to activate and register it with the network. If you are using pay and go, top up the SIM with some airtime credit. Test that the SIM can make and receive calls and can send and receive a SMS. Ensure the power is OFF. Slide the SIM card holder in the open direction, and carefully open the door. Do NOT force it. Connections on the GSM Controller Antenna connection GSM modem close open N/C COM N/O N/C COM N/O Out 2 Out 1 DC in 15v dc power in from power board eg Relay outputs 12v dc 12v dc output (not used) Pre-wired to push button Optional gate position limit switch Optional exit button, triggers output 1 for programmed time. Code Lock Keypad connections (Keypad versions only) Tamper N/C OUT2 Relay Select OUT3 N/C N/O N/O COM N/C + - egress Data I/O N/O N/C N/O COM N/C Power from power board INT Lock O/P1 inhib Sense (-)GND DU out K or A Commonly used connections Outputs – This keypad has 3 outputs. All can be programmed for momentary and latching operation. For gate systems and AC strike locks, connect a keypad relay (normally open) in parallel with the GSM module relay. For magnetic locks, connect in series with normally closed contact. Egress – This is for an optional exit button input, connected across this terminal and GND (-). OUT1 OUT2 Advanced connections INT Lock – Used to operate a door in conjunction with another keypad. 24v dc max voltage, 100mA sink. O/P1 inhib – When closed, this disables all codes for relay group 1. Sense – N/C connected to (-)GND, to be connected to N/C door contact. Can be used to generate door open or tamper alarm. DU out – switches to (-) ground after the Duress Code is entered. Used to trigger alarm zone, or buzzer to notify guard. 100mA sink, 24VDC. K or A – Not used. DATA I/O PORT (Data Communication Bus) The Data I/O port is prepared for setting up a data bus for the connection of the auxiliary reader-keypads and the split-decoder in system expansion P a g e |5 Connecting to a Gate Controller Intercom GSM Cellular controller N/O Common N/O COM Start COM Keypad Gate motor controller Alternative Keypad Wiring for Notification Feature The CellCOM+ model has an additional feature which sends an SMS to a master user when the GSM unit triggers it’s outputs. So if the user wants to know when the keypad is triggered, then wire a keypad output to egress input of the GSM as shown… Keypad GSM unit Output1 N/O COM N/C My gates opened! eg Powering Up Perform a final check of wiring and ensure the antenna is connected before switching on the power. Once the power is switched on, the power LED should illuminate. Power LED CPU LED Booting System booted GSM LED Searching 1 bar signal 2 bars signal 3 bars signal 4 bars signal P a g e |6 close open TIPS: My GSM LED is still searching… -Check the SIM card is registered and can make a call in a phone. -Check the SIM card is seated correctly. Power off, clean the contacts on the SIM and the GSM unit, and reinsert. -Check power cable distance and thickness. -Increase antenna height & change network. -Move antenna away from metal objects or overhanging shrubs. -Fit a high gain antenna. Programming TIP: The GSM unit programming is by sending SMS text messages to the unit from a phone. Step 1: Check Reception Send the SMS *20# as shown, to the SIM card number of the intercom. The unit should reply with a reception level between 1 and 31. *20# Signal level = 19 1-12 Poor 13-20 Medium 21-31 Good Note: Reception levels below 12 can give problems with the relay operation, and poor quality audio, or no audio coming from the microphone on the intercom (the person on the phone cannot hear anything), or buzz on the loud speaker. TIP: If reception levels are low, take action now! Either increase the height of the antenna to improve reception or request a higher gain antenna from your distributor or change to another network which may have better coverage. Step 2: Programming dial out numbers Programing text messages must start with a pass code string, followed by a command, followed by data, and each command is separated in the SMS by #. To begin, program the unit to dial numbers when the call button is pressed. This module will dial up to3 telephone numbers in sequence. 9999#111telephonenumber# Data Pass code Function code (add number) Telephone number position 1-4 Button number (1-10) TIP… 111 = Button 1, Tel number 1. 121 = Button 2, Tel number 1. 112 = Button 1, Tel number 2. 122 = Button 2, Tel number 2. 113 = Button 1, Tel number 3. 123 = Button 2, Tel number 3. The phone image shows an example of a number being stored and the reply sent by the unit to confirm OK. Up to 4 numbers can be sent in a single SMS. The pass code only needs entered at the beginning of each message, and then each new command string is separated by #. E.g. 9999#111firstnumber#112secondnumber#113thirdnumber# P a g e |7 9999#1110 987654321 # 11109876 54321 OK Step 3: Calling time This is the time the unit will spend attempting to call a number before aborting the call and calling the next number on the list. It is very useful to adjust this time so that if there is voicemail or answer machine on a number, that the intercom aborts the call before the machine picks up, otherwise the unit will think the call is answered and never call the next number. To adjust this time, send the following SMS messages… 9999#45??# Ringing time for first phone number (Where ?? = time in seconds 10-99) 9999#46??# Ringing time for second phone number (Where ?? = time in seconds 10-99) 9999#47??# Ringing time for third phone number (Where ?? = time in seconds 10-99) TIP: Remember to include the network connection time. A mobile phone needing to ring for 10 seconds may need a programmed ringing time of 15 seconds, because it can take 5 seconds to connect the call. Step 4: Caller ID access control This feature allows up to 100 numbers to be stored in memory. Any of these numbers can call the intercom. It will recognise the number, end the call without answering, and activate the output relay 1, all within a few seconds. Tip: The intercom only compares the last 6 digits of the number with memory; therefore it is not necessary to enter country codes. To add numbers, send the following SMS (up to 4 numbers can be entered in the same SMS)… 9999#7209 87654321# 9999#72telephonenumber#72telephonenumber#72tele phonenumber#72telephonenumber# . Tip: Even if a number is stored as a dialling out number when the call button is pressed, it needs stored again under the 72 feature if it is also required to have caller ID access. P a g e |8 72098765 4321 OK GSM unit complete list of parameters The table below show the complete list of features in the cellular part of the intercom. Programming messages below must begin with 9999# (assuming 9999 is still the programming passcode)… Changing pass codes 01????# 02????# 03????# 1XY????# 1XY*# Change programming password Change access control password (SMS control of relays, or nonstored numbers can call intercom & enter code to activate output 1). Change monitoring mode password (user can call the intercom, enter this pass code to listen in and speak) Dial out numbers Store dialling out numbers. (X = button number 1-9 & 0 for button 10) (Y = number dialled 1-4) (???? = phone number) Delete a dial out number. (X = button number) (Y = number position 1-4) Volume controls 9999 1234 5555 N/A N/A 3?# Speaker volume. Where ? = 1-9. 1 = lowest, 9 = highest. 5 4?# Microphone volume. Where ? = 1-9. 1 = lowest, 9 = highest. 5 Timings 50?# Relay 1 time. ? = seconds, 1-9999 1 sec 51?# Relay 2 time. ? = seconds, 1-9999. 1 sec 45??# 46??# 47??# 53????# 55??# 77number# 57??# 58?# 77*# 78number# 79text# 80?# P a g e |9 Calling time for first number, adjust this to avoid voicemail picking up a call (10-99 secs) Calling time for second number, adjust this to avoid voicemail picking up a call (10-99 secs) Calling time for third number, adjust this to avoid voicemail picking up a call (10-99 secs) Talking time. 5-9999 seconds. Max monitoring time (for listen in mode when calling the intercom) 00-60 mins. 00 = no limit. Scheduled service calls Store a service number to receive a scheduled call or SMS from the unit. Useful for SIM cards which are not often used to prevent switch off by the network provider. Set the time schedule for the intercom to make a scheduled call or SMS to the service number. 00-60 day time schedule. 00 = no call or SMS. Choose between making a scheduled call or scheduled SMS. 1 = SMS. 2 = call. Delete the stored service number Notification Number Store a master user, who will receive a SMS notification from the intercom each time any of the output relays are triggered. Where “text” is the content of the message to be sent. E.g. “Gates Opened, or Door Opened”. This will be sent on closing of any output relay. When ? = 1, this function is disabled. Set to 2 to enable. 20 secs 20 secs 20 secs 60 secs 10 mins N/A 00 1 N/A N/A N/A N/A Caller ID features Store caller ID number. Max 14 digits. Only last 6 digits compared. 72number# 73number# 73*# N/A Delete caller ID number. N/A Delete all caller ID numbers N/A Service & diagnostic messages (no passcode required for these!) *20# Check reception level 1-31 (no passcode needed) N/A *21# Check stored numbers. O = dial out number. I = dial in number. E = end of message. (no passcode needed) N/A *22# Check input status and relay status. (No passcode needed) N/A *23# Check the last 10 caller ID numbers which called the unit N/A 999# Send with passcode string to clear all programming. Restore Defaults N/A Keypad overview Now that the GSM part of the intercom is programmed and working, you may now program the keypad. The keypad is programmed directly on the keys, not remotely by SMS. This keypad has 3 outputs. The diagram below shows the LED indicators which indicate programming and relay status information. RED when incorrect codes entered and outputs are locked out. GREEN when output 1 activated. RED when output 2 activated. CLEAR when output 3 activated 1 2 3 4 5 6 7 8 9 * 0 # FAST FLASHING – Wrong code entered / error. SLOW FLASHING - in normal standby mode. ON in programming mode. ON when relay 3 activated. TIP: After power up, as a security precaution, the keypad cannot be programmed for 60 seconds. Once this time elapses, you may begin. TIP: Flashing amber LED is normal standby mode! Basic Keypad Programming Quick start guide 1) Enter programming mode (amber LED should be ON) 0 0 0 0 * * 2) Enter a new user code... 1 0 2 0 0 0 ? ? ? ? 3) Exit programming mode * * 4) Enter the new user code to check the relay clicks. P a g e | 10 # Tip: The engineer code must be the same length as user codes. So if using a 6 digit engineer’s code, then user codes must also be 6 digits long etc. Full Keypad programming Enter programming mode.. 0 0 0 0 * The unit is now in programming mode. Amber LED on the keypad should remain permanently on. 0000 is the default engineer’s passcode. * Exit programming mode.. * The unit should exit programming mode and the amber LED should start flashing again. * Enter or delete new user codes There are 3 groups of user codes. Group 10 for relay 1, group 20 for relay 2, and group 30 for relay 3. The programming sequence is shown below… 1 0 2 10= relay 1 codes (1000 available) 20= relay 2 codes (100 available) 30= relay 3 codes (100 available) 0 0 0 ? ? Memory locations 000-999 for relay 1 001-100 for relay 2 001-100 for relay 3 2= add code 5= delete code ? ? # Pin code 4-8 digits Validate Example: Add user 31 to have access code 5555 operating relay 2…. 2 0 2 Group 2 0 Add code 3 1 5 Location 31 5 5 5 Pin code 5555 # Validate Enter a new ENGINEER / PROGRAMMER code… Go into programming mode firstly then enter the following sequence… 0 1 ? Location ? ? ? # 4-8 digit code Replace ???? with your new ENGINEERS code.(Code length must be same as user code length). Validate Programming relay output times and modes… ? ? 0 or 1 - 9 9 9 9 0 = start / stop toggle mode (latching) 1-99999 = seconds momentary operation 51=relay1 52=relay2 53=relay3 Delete a user code even if you don’t know the code… ? ? 10=relay1 20=relay2 30=relay3 P a g e | 11 5 Delete code ? ? ? # ID location to be deleted Validate 9 # Validate Delete an entire group of codes ? ? 0 9 10=relay1 group 20=relay2 group 30=relay3 group 9 9 Super delete code # Validate Programming super user codes… A super user code can activate any of the 3 relays 0 2 ? ? Location ? ? 4-8 digit code # Validate Restoring defaults When in programming mode, you can enter the following sequence… 9 9 9 9 # Note: This does NOT delete the ENGINEERS code. When the ENGINEERS code is forgotten…. 1) Wire a push button (or replicate with wire link) across the Egress terminal and (-)GND. 2) Switch off power for 1 minute. 3) Switch ON power. 4) during the first 60 seconds, press the EG button once to enable the function. 5) Enter the following code.. 8 0 8 0 * * The keypad should now be in programming mode, ready to accept new data. Now change the Engineers code firstly. Using the keypad Using the standard codes… Once you have exited out of programming mode, simply enter the user code. Using super user codes ? ? ? ? # 1 Activate output 1 ? ? ? ? # 2 Activate output 2 ? ? ? ? # 3 Activate output 3 Using the intercom This cellular intercom can dial up to 4 numbers in sequence for any call button when pressed.. Dialling….. Phone 1 P a g e | 12 Phone 2 Phone 3 Any user receiving the call can answer, speak to the visitor, and press the following digits on their mobile or fixed line telephoneto control the relay on the device… Relay 1 Press 1 to trigger (use this mostly) Press 2 to Latch or hold open Press 3 to unlatch or close. 1 2 3 4 5 6 7 8 9 * 0 # Relay 2 Press 4 to trigger Press 5 to Latch or hold open Press 6 to unlatch or close Control by SMS This intercom allows the user to send SMS commands to control the relays and check status as follows… 1234#1# - Relay 1 momentary trigger. 1234#2# - Relay 1 latch ON or hold ON. 1234#3# - Relay 1 unlatch or switch OFF. 1234#4# - Relay 2 momentary trigger. 1234#5# - Relay 2 latch ON or hold ON. 1234#6# - Relay 2 unlatch or switch OFF. Check if door or gate is open or closed *22# OPEN, Relay 1 = OFF, Relay 2 = OFF Send the SMS as shown, and the unit will reply showing the status of the input limit switch (if used), and the relay.. This example shows that the input sensor is in OPEN state, and the relay is OFF. If the relay is latched, then the status will change to ON. If the input limit witch is closed, the status shown will change to CLOSED. TIP: If there is not a physical limit switch fitted to the door or gate, then the status input will always show OPEN. Using the Optional App Android and Iphone users can download an optional app called CELL BOX PLUS. P a g e | 13 This app performs several functions to ease the use of the intercom.. Main Trigger button Use this to speed dial intercom and momentary trigger the relay. Latch Relay Button Sends a preconfigured SMS to latch on the relay. Can be used to hold open gates or door. Trigger Gates Hold Open Unhold /Close Un-Latch Relay Button Sends a pre-configured SMS to unlatch the relay if it has previously been latched. Can be used to allow gates to close again. Status features Enter new screen to check signal strength, stored numbers, gate or door status. The main function of the app is to speed dial the intercom when entrance 1 main trigger button is pressed, and if any other button is pressed, it will send a SMS, just like those shown in the “Control by SMS” section above. Before the app will work, the phone number of the SIM card in the unit needs entered in the app settings along with the SMS strings used to latch and unlatch relays. Setting up the iphone APP Home screen Note labels show blank until names are entered. Note the NEXT button top right switches to entrance 2. P a g e | 14 Settings Use this screen to enter phone number of intercom and SMS messages. These can be copied from the SMS control section, and will be default strings unless the 1234 pass code has been changed. E.g. hold open entrance 1 = 1234#2# Labels Use this screen to enter names for the buttons. For example Front Gate for entrance one, and Rear Gate for entrance 2 if needed. Once saved these will appear on the home screen. Info Use this info screen to check gate position, relay status, reception, stored numbers etc. Setting up the Android APP Home screen Note Button labels show blank until names are entered. Press the MENU button on the android phone (bottom left) to go to settings! Note the NEXT button top right switches entrances. Entrance Settings Use this screen to enter phone number of intercom and default SMS messages. These can be copied from the SMS control section, and will be default strings unless the 1234 pass code has been changed. E.g. hold open entrance 1 = 1234#1# Button Labels Use this screen to enter names for the buttons. For example Front Gate for entrance one, and Rear Gate for entrance 2 if needed. Once saved these will appear on the home screen. Check Status Pressing the ? button on the home screen displays the options above where users can check status of gate positon and other parameters. Maintenance of the Intercom The intercom SIM card will need topped up occasionally if it is a pre-pay casual SIM card. It is recommended that you register this SIM card on the provider’s web site. You can register card payment details. Many networks offer an auto top up feature, which means they will automatically top up your intercom when the balance runs low. The stainless steel can dull or discolour over time in weather conditions. This can be polished with a suitable stainless steel cleaner. P a g e | 15 Troubleshooting guide Q. The unit will not power up. No LEDs on. A. Check power supply voltage at intercom is within 14.8V DC. Cable length from PSU to intercom should be less than 25 feet and in 14 gauge. Check the fuse. Q. The unit powers up but is not showing network reception or will not respond to SMS. A. This means the unit is not able to detect the network for some reason. -Power off the unit, remove the SIM and check it in a mobile phone to verify it can make a call and has calling credit. -Disable any PIN code request if active on the SIM card. -Check the SIM is a standard voice capable SIM. If you are unsure, contact your SIM card provider to verify. Compatible networks are At&T and T-Mobile. -Check the reception is medium or good. Poor reception is not sufficient. -Power off, remove the SIM, use fine sand paper to lightly sand the SIM pads and contacts on the GSM unit, lightly bend the contacts upwards so that they make better contact with the SIM and try again. Q. The unit calls the first number, but there is not enough time to answer before it diverts to the next number. A. Increase the no answer time as per programming instructions. Q. The unit calls the first number but voicemail comes on before it can ring the second number. A. Decrease the no answer time as per programming instructions. Q. The caller ID part does not work. A. Be sure to program the caller ID part under 72 feature. If your number is a private or number withheld, then it will not work. -Even if you have already programmed a number to receive a call from the intercom, if you also want that number to have caller ID access, it must be programmed under the 72 feature also. -Ensure the number is entered as you would normally dial it from another phone. Q. There is no audio from the gate, but the person at the gate can hear ok. A. This can be due to low reception or excessively long power cables. -Check reception level by *20#. -Change SIM card if necessary to another network which may have better coverage. -Purchase a high gain antenna. This may also be caused by a defective microphone, water on a microphone from a sprinkler for example, or dirt/insects blocking the microphone hole. If reception is optimum and the problem persists, contact your supplier or installer. Q. The audio quality that can be heard on the remote telephone is poor or humming (buzzing). A. A small amount of GSM buzz can be considered normal on GSM intercoms, but not so much that causes inability to hear the person speaking. This is a symptom of poor reception. Try above steps on checking and improving reception. Consider fitting an external high gain antenna. Q. The keys do not work when the intercom calls a phone. P a g e | 16 A. Check if you can hear the relay clicking at the gate when the keys are pressed during a call. If it can be heard, then the system is working, check wiring between the relay and the lock or gate panel. If the relays do not make a clicking sound, then check this feature on a different mobile cell phone or landline. If it works on a different phone, check the settings on the phone in question under DTMF tones. Failure of DTMF tones to operate correctly is also a symptom of low reception or insufficient power cabling. Check steps above on improving reception or addressing the power problem. -Also check that the relays are not already latched with the *22# command. If they are latched, they need unlatched before the trigger keys will work. -Sometimes excessively long power cables or thin power cables can cause this problem. Prove it by connecting a temporary extension lead and the power supply directly to the unit. Q. The keypad confirmation bleeps when I enter my code but the gates or door lock does not open. A. Check wiring. The keypad relay should be connected to the lock or gate system as well as the relay inside the GSM cellular part of the intercom. - Do not wire power to the intercom in alarm cable or CAT 5 cable. It should be proper power cable and the power cable length should be as short as possible. Otherwise relays may not fire. Q. The system was operating the gates fine, but now it will not trigger the gates. 99% of the time, this is cause by the user accidentally latching the relay. This latches the output relay permanently on. Send the intercom the following SMS *22#. The intercom should reply with a message detailing the relay status.. If it has been latched, then the message will state “the relay is ON”. In this case refer to the user guide to read how to unlatch it again. Q. The unit no longer calls out to phones but I can make a call to it from my phone. A – Check there is balance on the SIM card. A – Switch off the power, remove the SIM, put it into a phone, and check that a call can be made from a phone. This will verify if the SIM is still working and in service. P a g e | 17 P a g e | 18 Change History Key: P = Panel version P 1 Version H S 2 3 P a g e | 19 H = Hardware PCB version S = Software version Reason for change First version. Date 29/Jan/15 BFT Americas 6100 Broken Sound Parkway N.W. Suite 14, Boca Raton, FL 33487 www.bft-usa.com Toll Free: 877-995-8155 Office: 561-995-8155 Fax: 561-995-8160 P a g e | 20 ">
Download
Advertisement
Key features
GSM module with remote control
Caller ID access control
SMS command control
Optional APP for smartphone
Keypad for access control
Built-in microphone and speaker
Up to 3 numbers dialing
Relay outputs for gate/door control
Scheduled service calls
Notification SMS to master user
Frequently asked questions
The keypad programming is done directly on the keys. You can find the details in the section titled 'Full Keypad Programming'.
Send the intercom the SMS command '*22#' and it will reply with the relay status. If the relay is latched, the message will state 'the relay is ON'.
Check if there is balance on the SIM card and if the SIM is still working and in service. You can do this by switching off the power, removing the SIM, and putting it into a phone to see if you can make a call.
To program a new engineer code, enter programming mode, then enter the following sequence:
- 0
- 1
- [New engineer code]
The egress terminal is for an optional exit button input. This button can be used to trigger output 1 for a programmed time.