Instruction Manual
5300CI SMPTE
Timecode Interface
Revision: A
175-100134-00
Delivering the Moment
Publication Information
© 2014 Imagine Communications Corp. Proprietary and Confidential.
Imagine Communications considers this document and its contents to be proprietary and confidential.
Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of Imagine Communications. All others uses are illegal.
This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product.
Trademarks
6800+™, ADC™, CCS Navigator™, Channel ONE™, ChannelView™, ClipSync™, Delay™, D Series™, D Series DSX™, Deliver the Moment™, Delivering the Moment™, FAME™, Farad™, G8™, G Scribe™, HView™,
IconMaster™, IconLogo™, IconStation™, IconKey™, InfoCaster™, InfoCaster Creator™, InfoCaster Manager™, InfoCaster Player™, InstantOnline™, Invenio®, Live Update™, mCAPTURE™, Magellan™, Magellan CCS
Navigator™, Magellan Q SEE™, MultiService SDN™, NetPlus™, NetVX™, NewsForce™, Nexio® G8™, Nexio
AMP® ChannelView™, Nexio® Channel ONE™, Nexio® ClipSync™, Nexio® Delay™, Nexio® Digital Turnaround
Processor™, Nexio® Farad™, Nexio® G Scribe™, Nexio® IconKey™, Nexio® IconLogo™, Nexio® IconMaster™,
Nexio® IconStation™, Nexio® InfoCaster™, Nexio® InfoCaster Creator™, Nexio® InfoCaster Manager™,
Nexio® InfoCaster Player™, Nexio® InfoCaster Traffic™, Nexio® InstantOnline™, Nexio® mCAPTURE™, Nexio®
NewsForce™, Nexio® NXIQ™, Nexio® Playlist™, Nexio® Remote™, Nexio®RTX Net™, Nexio® TitleMotion™,
Nexio® TitleOne™, Nexio® Velocity ESX™, Nexio® Velocity PRX™, Nexio® Velocity XNG™, Nexio® Volt™,
OPTO+™, Panacea™, Platinum™, Playlist™, Predator II GRF™, Predator II GX™, Punctuate™, Remote™, RTX
Net™, QuiC™, Q SEE™, SD STAR™, Selenio™, Selenio 6800+™, SelenioNext™, Selenio X50™, Selenio X85™,
Selenio X100™, TitleMotion™, TitleOne™, Velocity ESX™, Velocity PRX™, Velocity XNG™, Versio™,
Videotek® SD STAR™, X50™, and X85™ are trademarks of Imagine Communications or its subsidiaries.
Altitude Express®, Connectus®, Enabling PersonalizedTV®, ICE® Broadcast System, ICE Illustrate®,
ICE Q® algorithms, ICEPAC®, Imagine ICE®, Inscriber®, Inscriber® Connectus®, Invenio®, NEO®, Nexio®,
Nexio AMP®, PersonalizedTV®, RouterWorks®, Videotek®, Videotek® ASI STAR®, Videotek® GEN STAR®, and Videotek® HD STAR® are registered trademarks of Imagine Communications or its subsidiaries.
Microsoft® and Windows® are registered trademarks of Microsoft Corporation. HD BNC is a trademark of
Amphenol Corporation. Some products are manufactured under license from Dolby Laboratories. Dolby and the double D symbol are registered trademarks of Dolby Laboratories. DTS Neural audio products are manufactured under license from DTS Licensing Limited. DTS and the Symbol are registered trademarks & the DTS Logos are trademarks of DTS, Inc. © 2008 2010 DTS, Inc. All other trademarks and trade names are the property of their respective companies.
Contact Information
Imagine Communications has office locations around the world. For locations and contact information see:
http://www.imaginecommunications.com/contact us/
Support Contact Information
For support contact information see:
▪ Support Contacts: http://www.imaginecommunications.com/services/technical support/
▪ eCustomer Portal: http://support.imaginecommunications.com
© 2014 Imagine Communications Corp. Proprietary and Confidential
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, and can radiate, radio frequency energy, and, if not installed and used in accordance with standard installation procedures and instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Table of Contents
5300CI
SMPTE COMPUTER TIME CODE INTERFACE
INSTRUCTION MANUAL
SECTION 1: Introduction
SECTION 2: Operational Modes
2.1
5300CI SMPTE Computer Time Code Interface . . . . . . . . . . . . . . . . 2-1
2.1.1
Time Code Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.2
Time Code Synchronizer . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.2
5300CI-G SMPTE Computer Time Code Interface . . . . . . . . . . . . . . . 2-2
2.2.1
Time Code Reader/Generator . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2.1.1
Time Code Reader . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2.1.2
Time Code Generator . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2.2
Time Code Synchronizer . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.3
Time Code Synchronized Generator . . . . . . . . . . . . . . . . . . . . 2-3
SECTION 3: Hardware Details
3.1
Input/Output Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.2
Setting the Output Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.3
Setting the Input Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.4
DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
SECTION 4: Other Software-Accessible Features
4.1
Interrupt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.2
Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.3
Initializing the Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.4
Interrupt Handler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.5
Reading Time Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.6
Miscellaneous Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
5300CI i
SECTION 1: Introduction
The 5300CI SMPTE Computer Time Code Interface provides simple-to-use SMPTE time code reading, or reading and generation, for IBM® PCs, ATs, and compatibles. It has its own built-in CPU, and does not require background processes that may interfere with other resident software. This card has two models: the 5300CI and the 5300CI-G.
Both the 5300CI and the 5300CI-G can be used as SMPTE longitudinal time code readers. These cards can read time code, and display it on the screen as hours, minutes, seconds, and frames. The reader is compatible with all formats of the SMPTE longitudinal time code.
The 5300CI-G is also designed to generate SMPTE longitudinal time code, allowing the user to set the start time and stop time code generation. Time code generation can continue while other programs are being executed on the PC. Please note that the reader and generator functions are mutually exclusive; that is, they cannot operate simultaneously.
In addition, both models of the 5300CI can be used to synchronize the clock in an IBM® PC, AT, or compatible to house (or Master) time distributed via SMPTE. With its generator function, the 5300CI-G can also serve as a source for house time.
5300CI 1-1
SECTION 2: Operational Modes
2.1 5300CI SMPTE Computer Time Code Interface
2.1.1 Time Code Reader
The 5300CI can be used as a direct SMPTE time code reader, using the program SMPTE.EXE on the support software distribution disk. Running the SMPTE program brings up a reader menu. The F10 key is used to exit the program.
NOTE: The reader program does not use interrupts.
When in the reader menu, the card is configured as a SMPTE time code reader. The current time code is displayed as read at the bottom of the menu. If no time code is being fed to the card, the words NO
SMPTE are displayed instead.
2.1.2 Time Code Synchronizer
The 5300CI can be used to synchronize the PC internal clock to a house time source distributed via time code. The program SMPTESET.COM performs this function.
SMPTESET is invoked by the following command line: SMPTESET /x where x is the interrupt number to be used by the card. This interrupt is set by Jumper J1 on the card. The interrupt to use is dependent upon the availability in a particular machine. Normal interrupt uses are as follows:
Interrupt
2
3
PC Usage
Usually free
COM2
AT Usage
Reserved
COM2
4
5
COM1
Fixed Disk
COM1
Free
6 Diskette Controller Diskette Controller
7 LPT1 LPT1
The recommended interrupt selections are 2 in PCs and 5 in ATs. Jumper the card correctly prior to its insertion in the machine. If Interrupt 2 is used, type: SMPTESET /2 . If Interrupt 5 is used, type:
SMPTESET /5
.
Once started, the SMPTESET program remains in memory, occupying less than 1KB. It keeps the system time equal to the received time at all times.
The SMPTESET program can also be started automatically each time the computer is booted by inserting the above command line in the computer’s AUTOEXEC.BAT file. This will cause the computer to lock to the external SMPTE signal, if available, each time the system is turned on.
NOTE: The program SMPTE cannot be run while SMPTESET is running, since this program assumes control of the 5300CI.
5300CI 2-1
SECTION 2: OPERATIONAL MODES
2.2 5300CI-G SMPTE Computer Time Code Interface
2.2.1 Time Code Reader/Generator
The 5300CI-G can be used as a direct SMPTE time code reader/generator. The program SMPTE.EXE on the support software distribution disk allows the card to be used as either a time code reader or generator.
Running the SMPTE program brings up one of two menus: a reader or a generator menu. The F1 is used to toggle between the menus. The F10 key is used to exit the program.
NOTE: The reader/generator program does not use interrupts.
2.2.1.1 Time Code Reader
When in the reader menu, the 5300CI-G is configured as a SMPTE time code reader. The current time code is displayed as read at the bottom of the menu. If no time code is being fed to the card, the words
NO
SMPTE are displayed instead.
2.2.1.2 Time Code Generator
When in the generator menu, the 5300CI-G is configured as a SMPTE time code generator. The generator menu has several options. The generation of time code can be started and stopped with the F2 and F3 keys, respectively. The operation of these keys is similar to the start and stop functions on a standard tape deck.
The F4 key allows the user to enter a new time code. If the generator is running at the time this function is selected, it will be stopped so that the user can enter the new time code. The generator must then be restarted by pressing F2.
The F5 key stops the generator and presets the time code to 1:00:00/00. This is a common start time for programs that utilize time code. Starting a program at this point ensures that the program will not cross
0:00:00/00 (a problem for some synchronizers), but will have some room at the beginning for adding lead-ins, etc. Following the preset, the generator must be restarted by pressing F2.
The F6 key synchronizes the time code generator to the PC clock. This makes it easy to synchronize two or more PCs to the same time. The generator restarts immediately.
NOTE: The generator does not stop upon exiting from the SMPTE program. The generator continues to operate in a background even after the program has been exited.
2-2 5300CI
SECTION 2: OPERATIONAL MODES
2.2.2 Time Code Synchronizer
The 5300CI-G can be used to synchronize the PC internal clock to a house time source distributed via time code. The program SMPTESET.COM performs this function.
SMPTESET is invoked by the following command line: SMPTESET /x where x is the interrupt number to be used by the card. This interrupt is set by Jumper J1 on the card. The interrupt to use is dependent upon the availability in a particular machine. Normal interrupt uses are as follows:
Interrupt
2
3
PC Usage
Usually free
COM2
AT Usage
Reserved
COM2
4
5
COM1
Fixed Disk
COM1
Free
6 Diskette Controller Diskette Controller
7 LPT1 LPT1
The recommended interrupt selections are 2 in PCs and 5 in ATs. Jumper the card correctly prior to its insertion in the machine. If Interrupt 2 is used, type: SMPTESET /2 . If Interrupt 5 is used, type:
SMPTESET /5
.
Once started, the SMPTESET program remains in memory, occupying less than 1KB. It keeps the system time equal to the received time at all times.
The SMPTESET program can also be started automatically each time the computer is booted by inserting the above command line in the computer’s AUTOEXEC.BAT file. This will cause the computer to lock to the external SMPTE signal, if available, each time the system is turned on.
2.2.3 Time Code Synchronized Generator
The 5300CI-G can be used to generate time code synchronized to the PC internal clock in order to serve as a house time source. The program SMPTEGEN.COM performs this function.
SMPTEGEN is invoked by the following command line: SMPTEGEN /x where x is the interrupt number to be used by the card. This interrupt is set by Jumper J1 on the card. The interrupt to use is dependent upon the availability in a particular machine. Normal interrupt uses are as follows:
Interrupt
2
3
PC Usage
Usually free
COM2
AT Usage
Reserved
COM2
4
5
COM1
Fixed Disk
COM1
Free
6 Diskette Controller Diskette Controller
7 LPT1 LPT1
The recommended interrupt selections are 2 in PCs and 5 in ATs. Jumper the card correctly prior to its insertion in the machine. If Interrupt 2 is used, type:
SMPTEGEN /2
. If Interrupt 5 is used, type:
SMPTEGEN /5 .
Once started, the SMPTEGEN program remains in memory, occupying less than 1KB. It keeps the generated time equal to the system time at all times. Normally, SMPTEGEN will be installed in the computer’s AUTOEXEC.BAT file.
5300CI 2-3
SECTION 2: OPERATIONAL MODES
NOTE: The program SMPTE cannot be run while either SMPTESET or SMPTEGEN are running, since these programs assume control of the 5300CI-G.
2-4 5300CI
SECTION 3: Hardware Details
3.1 Input/Output Connections
The time code input is a balanced audio input. Pins 2 and 3 of the DB-15 connector are for input, with
Pin 1 used for ground. Polarity is not important on the input or output. If an unbalanced input is used, ground the other input pin.
Time code output is on Pins 5 and 6, with Pin 4 being the associated ground. The input and output levels are preset to 0 dBm.
3.2 Setting the Output Level
The time code output left is preset at the factory to 0 dBm. This level can be adjusted by varying the setting of R20. This pot is labeled OUT on the card.
With the card in the generator mode, adjust R20 until the desired level, as measured on the output terminals, is achieved. Turning the control to the right increases the output level. It is recommended that this adjustment be made with the card connected to normal output termination (600
Ω
).
3.3 Setting the Input Level
The input level control, R6, is adjusted at the factory for maximum capture range. Field adjustment should not be necessary, and is not recommended.
3.4 DIP Switch Settings
The 5300CI and 5300CI-G SMPTE Computer Time Code Interfaces have been preconfigured to an address of 310h. The software included with the card expects it to be at that address. The correct DIP switch settings, should they be changed accidentally, are as follows:
6
7
8
3
4
5
Switch Setting
1 ON
2 ON
OFF
ON
ON
ON
OFF
OFF
5300CI 3-1
SECTION 4: Other Software-Accessible Features
NOTE: This information is furnished as a courtesy to users of the
5300CI and 5300CI-G SMPTE Computer Time Code Interfaces who may wish to make use of additional features of the card that are not available with the standard software provided.
Utilization of the information supplied herein may require proficiency in computer programming.
No warranty is provided on the information or features described herein, nor will any further support of any kind be given except on a custom basis at additional cost.
Modifications to the 5300CI and
5300CI-G may be made without notification, and there are no guarantees that the software features described herein will be supplied or supported in the future.
4.1 Interrupt
The following information is necessary when using the 5300CI in a customized programming environment.
1) The interrupt is jumper-settable on the card, and is usually set to 5.
2) The I/O address is 310h (DIP Switch selected). There is only one address.
3) The interrupt is generated immediately following time code receptions, where the seconds field is 30, and the frames field is 0.
4) Additional interrupt options are available at the beginning and end of time code, and upon response to the PC system.
5) Interrupts are also generated when time code is lost and regained.
6) Time is set once per minute.
4.2 Commands
The procedure for sending a command to the 5300CI is as follows:
1) Output the command to 310h.
2) Read 310h, and wait for the commands response. This step is required if a fast PC is used. The response time is several milliseconds.
3) To avoid a BUSY WAITING FOR COMMAND response, the card can be set to generate an interrupt upon response, allowing for a fully interrupt-driven support routine.
5300CI 4-1
SECTION 4: OTHER SOFTWARE-ACCESSIBLE FEATURES
Command Description
commandPC Receives commands from the PC and executes them.
28h
29h
2ah
2bh
2ch
2dh
2eh
2fh
0000xxxx
0001xxxx
001000xx
0011xxxx
0100xxxx
0101xxxx
01100xxx
0111xxxx
1000xxxx
1001xxxx
10100xxx
1011xxxx
1100xxxx
1101xxxx
111000xx
1111xxxx
Set Frame units
Set User Group 1, 4 bits
Set Frame tens
Set User Group 2, 4 bits
Set Seconds units
Set User Group 3, 4 bits
Set Seconds tens
Set User Group 4, 4 bits
Set Minutes units
Set User Group 5, 4 bits
Set Minutes tens
Set User Group 6, 4 bits
Set Hours units
Set User Group 7, 4 bits
Set Hours tens
Set User Group 8, 4 bits
Clear enhanced (29h — 2fh) features
Set host interrupt on each response
28h
29h
Set host interrupt at end of time code 2ah
Set host interrupt at start of time code 2bh
Set writes to buffer time
Set writes to generator time
Set buffer time valid for send
2ch
2dh
2eh
26h
27h
24h
25h
26h
27h
24h
25h
26h
27h
24h
25h
24h
25h
26h
27h e8h e9h eah ebh ech edh
Rec Time read request
Gen Time read request
Set stopped mode
Set receive mode
Set generating mode
Get current mode
Dummy Commands for Synchronization
eeh Dummy Command efh Dummy Command
Response
e8h e9h eah ebh ech eah, ebh, ech eeh efh
4-2 5300CI
SECTION 4: OTHER SOFTWARE-ACCESSIBLE FEATURES
Command Description
68h
69h
Read rfru - Frame units
Read rug1
- User Group 1, 4 bits
6ah
6bh
6ch
6dh
6eh
Read
Read rfrt - Frame tens rug2
- User Group 2, 4 bits
Read rsecu - Seconds units
Read rug3
- User Group 3, 4 bits
Read rsect
- Seconds tens
6fh a8h a9h aah abh ach adh aeh afh
Read rug4
- User Group 4, 4 bits
Read rminu
- Minutes units
Read rug5 - User Group 5, 4 bits
Read rmint
- Minutes tens
Read rug6 - User Group 6, 4 bits
Read rhru
- Hours units
Read rug7 - User Group 7, 4 bits
Read rhrt
- Hours tens
Read rug8 - User Group 8, 4 bits
Interrupt Status Values
68h Time set interrupt (Seconds=30, Frames=0)
69h
6ah
6bh
6ch
Gained time code
Lost time code
End of time code interrupt (after User Group 8)
Start of time code interrupt (after last sync bit)
Response
0000xxxx
0001xxxx
001000xx
0011xxxx
0100xxxx
0101xxxx
01100xxx
0111xxxx
1000xxxx
1001xxxx
10100xxx
1011xxxx
1100xxxx
1101xxxx
111000xx
1111xxxx
No SMPTE time code is indicated by a frame unit of h’f (normally impossible).
NOTE: Enhanced features 28h — 2fh and the interrupt status values were added in Firmware Revision 2.02, and are not available in earlier firmware revisions. Contact the factory for information on an update.
4.3 Initializing the Card
The procedure for initializing the card is as follows:
1) Send the Set Receive Mode command (ebh).
2) Set the interrupt vector in the PC.
3) Activate the interrupt vector in the PC (unmask).
5300CI 4-3
SECTION 4: OTHER SOFTWARE-ACCESSIBLE FEATURES
4.4 Interrupt Handler
The Interrupt Handler does the following:
1) Reads time code from the card.
2) Sets the PC clock from time code.
4.5 Reading Time Code
1) Send the Rec Time read request (e8h). This causes the current time to be copied into a reading area. This is done to allow accurate asynchronous reads.
2) Read each 4-bit SMPTE group using commands 68h — afh. Obviously, if the user bits are not needed, it is not necessary to read them. These can be read in any order.
4.6 Miscellaneous Notes
1) Reading the card port clears the interrupt. You must also be sure to clear the PC interrupt controller (ie.
out 20h,20h
).
2) A lack of input time code is indicated by a frame unit of 0fh
.
3) The 5300CI cannot send and receive at the same time.
4) The data read is raw, and includes drop frame, color bits, etc.
4-4 5300CI
Customer Service Support
+1 888 534 8246
Harris is a registered trademark of Harris Corporation. Trademarks and tradenames are the property of their respective companies.
Broadcast Communications Division
25 Dyas Road | North York, ON M3B 1V7 | Tel: 1 (416) 445 9640
www.broadcast.harris.com
©2009 Harris Corporation
Preuzimanje
Reklama