SOHO E-MEDICAL INDUSTRY EMERGENCY

6

VFI

TYPE

ONLINE Tower

1:1 700-3000 VA

USB plug

GS Nemko certified

Supercaps

UPS

Plug & Play installation

HIGHLIGHTS

• Power factor 0,9

• Operating flexibility

• Emergency function

• Battery optimisation

• Runtime expandability

• Low noise level

Sentinel Pro has a unique and modern design and improved performance developed by the Riello UPS research and development team. Sentinel Pro uses on-line double conversion technology, resulting in the highest levels of reliability and maximum protection for critical loads such as servers, and IT and voice/data applications.

For business continuity applications requiring long battery runtimes, battery autonomy can be extended up to several hours using ER models fitted with more powerful battery chargers.

The front display panel has been entirely redesigned, adding an LCD display that shows the input and output voltages, battery readings and UPS operating status information. The inverter and the microprocessor control stage has been completely redesigned to provide increased efficiency and greater configuration options.

Maximum expandability: the Sentinel Pro is supplied as standard with a USB port and an expansion slot for protocol conversion or relay contacts boards.

With energy savings in mind, Sentinel

Pro is also fitted with a shut-off button to reduce energy consumption to zero during prolonged periods of inactivity (ECO LINE).

Sentinel Pro is available in 700 VA, 1000

VA, 1500 VA, 2200 VA and 3000 VA models.

Operating flexibility

Different operating modes that can be programmed according to user requirements and the load to be powered have been introduced in order to reduce energy consumption.

On line: maximum load protection and output voltage waveform quality

Economy Mode: the UPS uses line interactive technology, with the load powered by the mains, reducing consumption and thus improving efficiency (up to 98%).

Smart Active Mode: the UPS automatically selects on-line or line interactive operation, depending on the quality of the mains supply, checking the number, frequency and type of disturbances present.

Stand by Off (emergency): The UPS supplies the load only when the mains fails. The inverter begins working with a progressive start-up sequence to prevent inrush currents.

Frequency converter operation (50 or 60

Hz).

Emergency function

This configuration ensures the operation of emergency systems that must be supplied in the event of a mains power failure, such as emergency lighting, fire detection/ extinguishing systems and alarms. When the mains power supply fails, the inverter begins powering the loads with a progressive startup (Soft Start) in order to prevent overload.

Sentinel Pro is compliant for installation in medium-voltage transformer rooms in accordance with applicable legislation, for the power supply with reserve charge of medium-voltage coils.

Battery optimisation

The Sentinel Pro range has a deep discharge protection device to optimise battery life.

Periodically the UPS carries out a battery efficiency test (which can also be manually activated); its wide input voltage tolerance range helps to reduce battery usage and maintain performance over time.

Runtime expandability

Optional battery extension packs can be connected to increase UPS runtime. In addition the Sentinel Pro range includes

ER versions with no internal batteries and more powerful battery chargers for longer runtimes.

Low noise level

Thanks to the use of high frequency components and load-based fan speed control, the noise produced by the UPS is less than 40 dBA.

Features

• Filtered, stabilised and reliable voltage: double conversion on-line technology

(VFI compliant with IEC 62040-3) with filters for the suppression of atmospheric disturbances.

• High overload capability (up to 150%)

• Programmable Auto-restart when mains is restored

• Battery start-up (cold start)

DETAILS

SEP 3000 - SEP 3000 ER

SEP 2200 - SEP 2200 ER

SEP 700

SEP 1500

SEP 1000

SEP 1000 ER

USB PORT

RS232

SERIAL

INTERFACE

REPO

CONNECTOR

COMMUNICATION SLOT

BATTERY EXPANSION

CONNECTOR

OUTPUT SOCKETS

INPUT SOCKET

• Power factor correction (UPS input power factor, close to 1)

• Wide input voltage tolerance range

(from 140 V to 276 V) without battery intervention.

• Runtime extendable up to several hours

• Fully configurable using UPS Tools configuration software

• Highly reliable batteries (automatic and manually-activated battery test)

• High level of UPS reliability (total microprocessor control)

• Low impact on the mains (sinusoidal take up).

Advanced communications

• Multi-platform communication for all operating systems and network environments: PowerShield 3 supervision and shutdown software for Windows operating systems 10, 8, 7, Hyper-V, 2016,

2012, and previous versions, Mac OS X,

Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems

• UPS Tools configuration and customisation software supplied as standard

• RS232 serial port and opto-isolated contacts

• USB port

• Slot for communications boards.

2-YEAR WARRANTY

OPTIONS

SOFTWARE

PowerShield 3

PowerNetGuard

ACCESSORIES

NETMAN 204

MULTICOM 302

MULTICOM 352

MULTICOM 372

MULTICOM 382

MULTICOM 401

MULTI I/O

Interface kit AS400

MULTIPANEL

Manual Bypass 16 A

Automatic Bypass 16 A

BATTERY BOX

MODELS BB SEP 36-A3 / BB SEP 36-M1 BB SEP 72-A3 / BB SEP 72-M1 BB SEP 36-B1 / BB SEP 72-B1

Dimensions

(mm)

BB

158

422

190

BB

446

BB

215

655

MODELS

POWER

INPUT

Nominal voltage

Voltage range without battery intervention

Voltage tolerance

Maximum permitted voltage

Nominal frequency

Frequency range

Power factor

Current distortion

BYPASS

Voltage tolerance

Frequency tolerance

Overload Times

OUTPUT

Voltage distortion with linear load / with non-linear load

Frequency

Static variation

Dynamic variation

Waveform

Current crest factor

Efficiency

ECO and Smart Active Modes

BATTERIES

Type

Recharge time

OTHER FEATURES

Net weight (kg)

Gross weight (kg)

Dimensions (WxDxH) (mm)

Packaging dimensions

(WxDxH) (mm)

Protection against overvoltage

Protections

Communications

Input plugs

Output sockets

Standards

Operating temperature

Relative humidity

Colour

Noise level at 1 m (ECO Mode)

Standard equipment provided

SEP 700 SEP 1000 SEP 1000 ER SEP 1500 SEP 2200 SEP 2200 ER SEP 3000 SEP 3000 ER

700 VA/630 W 1000 VA/900 W 1500 VA/1350 W 2200 VA/1980 W 3000 VA/2700 W

10,9

12,5

140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD

2-4 hours

13,3

14,9

7

8,6

158 x 422 x 235

245 x 500 x 340

220-230-240 Vac

230 Vac ± 20%

300 Vac

50/60 Hz

50 Hz ± 5% / 60 Hz ± 5%

> 0,99

≤7%

180 - 264 Vac

Frequency selected (from ±1,5Hz to ±5Hz configurable)

125% for 5 seconds, 150% for 1 second

< 2% / < 4%

Selectable: 50 Hz or 60 Hz or self-learning

± 1%

≤ 5% in 20 msec.

Sinusoidal

3 : 1

14,8

15,5

98%

VRLA AGM maintenance-free lead based; Supercaps

N.A.

2-4 hours N.A.

25,6

28,8

2-4 hours

14

17

28

31,2

190 x 446 x 333

325 x 585 x 470

300 joules

Overcurrent - short-circuit - overvoltage - undervoltage - temperature - excessive low battery

USB / DB9 with RS232 and contacts / Slot for communications interface

1 IEC 320 C14 1 IEC 320 C20

4 IEC 320 C13 8 IEC 320 C13 + 1 IEC 320 C19

Safety: EN 62040-1 and Directive 2006/95/EL; EMC: EN 620040-2 and Directives 2004/108/EL

0 °C / +40 °C

< 95% non-condensing

Black

< 40 dBA

Power cable, IEC-IEC cable, USB cable, safety manual, quick start guide

N.A.

15

18

Cetronic Power Solutions Ltd

Sales: 01920 871077 – Email: [email protected] – Website: www.cetronicpower.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement