SPARK MODERN FIRES

512/612

 

BUILT-IN DIRECT VENT GAS FIREPLACE

INSTALLATION  &  OPERATION  MANUAL  

Report  #0361GF006S  

Ce manual est disponsible en Francais sur demande.

This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

Model Descriptions

Specifications

Clearances

Installation Information

Venting

Final Assembly

Lighting & Operation

Remote Handset Operation

Gas Conversion

Maintenance

Maintenance Log

Replacement Parts List

Control Schematic

Installation Record

Warranty Information

TABLE OF CONTENTS

Important Safety Information

WE STRONGLY SUGGEST THAT YOU READ THIS MANUAL THOROUGHLY BEFORE BEGININNG THE

INSTALLATION OF THE DIRECT VENT GAS FIREPLACE. ALTHOUGH THE BASIC REQUIREMENTS FOR

THE INSTALLATION OF ALL DIRECT VENT GAS FIREPLACES ARE SIMILAR, EACH SPECIFIC PRODUCT HAS

ITS OWN UNIQUE SET-UP AND INSTALLATION REQUIREMENTS THAT MUST BE FOLLOWED EXACTLY.

PLAN YOUR INSTALLATION IN ADVANCE BY CAREFULLY RE-VIEWING ALL THE INFORMATION

CONTAINED IN THIS MANUAL.

20

24

26

11

14

16

4

6

7

36

37

33

35

38

39

40

3

IMPORTANT SAFETY INFORMATION

The installation must conform with local codes or, in the absence of local codes, with the National Fuel

Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

A manufactured home (USA only) or mobile home OEM installation must conform with the

Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 or when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/BCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.

The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than

1/2 psi (3.5 kPa).

The installation must provide for adequate ventilation air to the appliance.

This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.

The appliance, when installed, must be electrically grounded in accordance with local codes, or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, or the Canadian Electrical Code,

CSA C22. 1.

The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids.

The flow of combustion and ventilation air must not be obstructed. Adequate accessibility clearances must be maintained for servicing and proper operation of this appliance.

Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at-risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at-risk individuals out of the room and away from hot surfaces.

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.

If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.

Clothing or other flammable material should not be placed on or near the appliance.

Any screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.

4

IMPORTANT SAFETY INFORMATION

Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartments, burners and circulating air passageways of the appliance be kept clean.

WARNING: Do not operate the appliance with the glass door assembly removed, or if the glass is cracked or broken. Replacement of the glass should be done by a qualified service person.

WARNING: Use only glass assembly, P/N 48-510 which includes the glass panel, frame and gasket. Do not use substitute materials. Do not strike or slam the glass front. Do not use abrasive cleaners. Do not clean when hot.

CAUTION: DO NOT OPERATE WITH BROKEN GLASS

Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passageways of the appliance be kept clean.

Note:

Periodically conduct a visual check to ensure the pilot and burner flames are as shown (right).

Vent Installation Note:

When the first piece of Directvent pipe is attached to the starter collar of the fireplace, be sure to inspect both the inside and outside joints to ensure a secure fit with no air gaps. Once it is confirmed there are no gaps, rotate the pipe clockwise to lock it in place.

Follow the vent manufacture’s installation instructions during vent pipe installation.

5

512 VU-THRU

MODEL NO. BI-60-ST

612 VU-THRU

MODEL NO. BI-72-ST

MODEL DESCRIPTIONS

6

SPECIFICATIONS

CERTIFICATION

This appliance has been certified by OMNI-Test Laboratories, Inc. to ANSI Z21.88-2014/CSA 2.33-2014 Vented

Gas Fireplace Heaters and CAN/CGA-2.17-M91 (R2014), Gas-Fired Appliances for Use At High Altitudes.

This SPARK MODERN FIRES Gas Fireplace is approved for installation at elevations up to 2000 feet in the

U.S. and 1370 meters (4500 feet) in Canada without change. If your installation is at an elevation greater than these, consult with the local authority having jurisdiction for gas product installations to determine their specific requirements for high altitude installations.

These appliances are approved for installation in the Commonwealth of Massachusetts by the Board of

State Examiners of Plumbers and Gas Fitters.

Sample Rating Label (affixed to control panel within firebox)

7

SPECIFICATIONS

INPUT

Input Rating BTU/Hr.

Min. Input BTU/Hr.

Orifice Size - DMS

GAS SUPPLY

Manifold Pressure

Min. Supply Pressure

Max. Supply Pressure

512 VU-THRU

30,000

21,000

#49

512 VU-THRU

3.5” w.c. / 0.9kPa

5.5” w.c. / 1.4kPa

10.0” w.c. / 2.5kPa

612 VU-THRU

34,000

27,000

#46

612 VU-THRU

3.5” w.c. / 0.9kPa

5.5” w.c. / 1.4kPa

10.0” w.c. / 2.5kPa

INPUT

Input Rating BTU/Hr.

Min. Input BTU/Hr.

Orifice Size – DMS

GAS SUPPLY

Manifold Pressure

Min. Supply Pressure

Max. Supply Pressure

512 VU-THRU

34,000

25,000

#56

512 VU-THRU

10.0” w.c. / 2.5kPa

11.0” w.c. / 2.8kPa

13.0” w.c. / 3.3kPa

612 VU-THRU

40,000

28,000

#55

612 VU-THRU

10.0” w.c. / 2.5kPa

11.0” w.c. / 2.8kPa

13.0” w.c. / 3.3kPa

Efficiency NG/LP

*Typical Installation, Steady State Efficiency - %

Steady State Efficiency - %

Annual Fuel Utilization Efficiency (AFUE) - %

512 VU-THRU

69/73.9

64.8/70.8

62.8/68.6

612 VU-THRU

72.6/76.4

70.4/74.8

68.2/72.5

Canadian p.4 Efficiency - % 64.5/67.7

*Your efficiency will increase with the length of the vent run. The typical installation tested is 5ft vertical and 5ft horizontal.

69.8/72.7

NOTE: The maximum achievable steady state efficiency can vary depending on how the fireplace is installed and operated.

It is recommended that the pilot flame be turned off if the appliance will not be in use for an extended period of time.

This appliance is equipped for use with the fuel type indicated on the rating plate. Field conversion is only permitted with a conversion kit supplied by SPARK MODERN FIRES.

8

SPECIFICATIONS

512 VU-THRU 612 VU-THRU

Dimension “A”

Dimension “B”

Dimension “C”

Dimension “D”

Dimension “E”

Dimension “F”

Dimension “G”

29” (737mm)

73.625” (1,870mm)

59.25” (1,505”)

12.75” (324mm)

2.70” (69mm)

11.30” (287mm)

7.95” (202mm)

29” (737mm)

87.625” (2,226mm)

73.25” (1,861mm)

12.75” (324mm)

2.70” (69mm)

11.30” (287mm)

7.95” (202mm)

Dimension “H”

*Dimension “J”

*Dimension “K”

8.125” (206mm)

3.25” (83mm)

30.25” (768.5mm)

8.125” (206mm)

3.25” (83mm)

30.25” (768.5mm)

Dimension “L”

Dimension “M”

11.50” (292mm)

23.875” (606.5mm)

11.50” (292mm)

23.875” (606.5mm)

Dimension “N” 12” (305mm) 12” (305mm)

*The Horizontal and Vertical vent centerline dimensions’ account for the use of a 45-degree elbow.

The gas fireplace is shipped with a 3/8” tube OD (female) connection. The gas supply piping should have a separate gas shutoff valve and a 1/8” NPT plugged tapping upstream of the valve. The stove and its main control valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). The stove must be isolated from the gas supply piping system by closing the main control valve during any pressure testing of the gas supply system at test pressures equal to or greater than 1/2 psi (3.5 kPa). After the gas supply has been connected, use a commercial gas leak detector or apply a soapy water solution to all the fittings to check for gas leaks. Never use a flame to test for leaks.

9

Sides

Floor

Back

Front

Clearance around vent pipe

CLEARANCES

512 VU-THRU

4” (102mm)

1/2” (13mm)

12” (305mm)

12” (305mm)

1.5” (38mm)

612 VU-THRU

4” (102mm)

1/2” (13mm)

12” (305mm)

12” (305mm)

1.5” (38mm)

The image above shows a typical installation.

All framing, finishing, and construction materials that fall within 4” (102mm) of either the sides or top of the fireplace must be non-combustible and ½” below the unit.

Any materials that cover the front face or rear face of the fireplace must be non-combustible.

Allow clearance for removal of fireplace trim, screen, and glass.

The fireplace must be secured to the framing studs using the nailing flanges as shown above.

Use 2 screws or nails per nailing flange to secure the fireplace.

The sheet metal face of this fireplace must be covered by a non-combustible material, it may not be left exposed.

The floor the fireplace immediately rests on must be constructed of non-combustible material with an R factor of at least .37, with a minimum thickness of ½” (13mm).

10

FRAMING BEFORE INSTALLATION

CLEARANCES

Sometimes it is necessary to frame the location you will be installing the fireplace before the fireplace is onsite, the above image shows an example of how to frame the wall before the fireplace is moved into position.

All framing, finishing, and construction materials that fall within 4” (102mm) of either the sides or top of the fireplace must be non-combustible. (shown with a dashed line in the image above)

Note that the vent starter collar sits slightly above the top surface of the fireplace can, there must be clearance to allow the fireplace with starter collar to slide into place.

The floor the fireplace immediately rests on must be constructed of non-combustible material with an R factor of at least .37, with a minimum thickness of ½” (13mm).

This framing guide is just an example of the many ways in which a SPARK MODERN FIRES

Fireplace can be installed. You may need to customize this framing design to allow for things such as doors, windows, countertops, structural frame members or local code requirements.

Dimension “B” for your model can be found on page 8.

11

CLEARANCES

WARNING

Follow these instructions carefully to ensure safe installation.

Failure to follow instructions exactly can create a fire hazard.

The combustible area above the facing must not protrude more than ¾ (19mm) from the facing; if it does, it is considered a mantel and must meet the mantel requirements on the following page.

When selecting non-combustible materials for use in the installation, take note of the material’s propensity to absorb and conduct heat. Materials such as metal, stone, and ceramics may transmit heat more readily than other building materials.

Only non-combustible materials (i.e. brick, tile, slate, steel, or other man made materials with a

UL fire rating of Zero) may be used in the construction and installation of this fireplace. Any material must be fastened to surrounding framing. NOT to the face of the fireplace.

ATTENTION:

Before proceeding with your installation, determine if you plan to use either the Power Vent kit (PV-

800HZ) or the Heat Redistribution Kit (HRD-750). Read the manual for these optional components before proceeding with your installation, as your installation requirements and procedure may change.

12

INSTALLATION INFORMATION

WARNING

Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage, or loss of life. Operation of improperly installed or maintained venting system could result in serious injury, property damage, or loss of life.

NOTE:

Any electrical wiring, gas plumbing, or vent installation required by the appliance must be done prior to final finishing. The unit shall be test burned on high for at least 30 minutes prior to final finishing to confirm proper operation. Failure to test the appliance before final finishing may require significant and costly reconstruction

INSTALLATION PRECAUTIONS:

Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing the vent kit, the installer must read this fireplace manual and vent kit instructions. Only a qualified, licensed, installer/service person shall install the venting system. The installer must follow the following safety rules:

Wear gloves and safety glasses for protection.

Use extreme caution when using ladders or when on rooftops.

Be aware of electrical wiring locations in walls and ceilings.

The following actions will void the warranty on your fireplace:

Installation of any damaged venting component.

Unauthorized modification of the venting system.

Installation of any component part not manufactured or approved by SPARK MODERN FIRES

Contemporary Fires.

Installation other than permitted by these instructions.

NOTICE

Failure to follow these instructions will void the warranty.

13

INSTALLATION INFORMATION

State of Massachusetts:

The installation must be completed by a licensed plumber or gas fitter in the Commonwealth of

Massachusetts.

REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS

This product must be installed by a licensed plumber or gas fitter when installed within the

Commonwealth of Massachusetts. If this appliance is installed in a dwelling, building or structure used in whole or in part for residential purposes and the installation includes a horizontal vent termination that is less than seven (7) feet above the finished grade in the area of the venting, including but not limited to decks and porches, a hard-wired carbon monoxide detector with an alarm and battery back-up must be installed on the floor level of the dwelling, building or structure where the appliance is to be installed.

Additionally, a hard-wired or battery operated carbon monoxide detector with an alarm must be installed on each additional level of the dwelling, building or structure served by the appliance. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard-wired carbon monoxide detectors.

In the event that the horizontally vented appliance is installed in a crawl space or attic, the hardwired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that this requirement cannot be met at the time of completion of the installation of the appliance, the owner shall have a period of thirty (30) days to comply with the requirement. However, during said thirty (30) day period, a battery operated carbon monoxide detector with alarm must be installed.

Each carbon monoxide detector as required in accordance with the above provisions must comply with NFPA 720 and be ANSI/UL 2034 and IAS certified.

In addition, when the vent termination is less than seven (7) feet above finished grade a metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP

CLEAR OF ALL OBSTRUCTIONS”.

A COPY OF THESE INSTRUCTIONS PLUS ALL VENTING INSTRUCTIONS WHICH IN-CLUDE PARTS LISTS,

AND/OR ALL VENTING DESIGN INSTRUCTIONS MUST REMAIN WITH THE STOVE AT THE COMPLETION

OF THE INSTALLATION.

ATTENTION INSTALLERS: Mark below which venting system was used in the installation. These instructions must remain with the SPARK MODERN FIRES Gas Fireplace Installation & Operation

Manual.

O

Simpson DuraVent GS/PRO®

O

AmeriVent Direct™

O

Selkirk Direct-Temp®

O

Security Secure Vent™

O

Metal Fab Direct Vent

O

ICC Direct Vent

14

VENTING

WARNING

This fireplace must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems.

INSTALLATION PLANNING

The 512 VU-THRU, and 612 VU-THRU use 4x6 Direct-vent pipe.

There are two basic types of direct-vent installation:

Horizontal Termination

Vertical Termination

It is important to select the proper length of vent pipe for the type of termination you choose, taking into consideration wall thicknesses.

FOR HORIZONTAL TERMINATION

Select the amount of vertical rise desired. All horizontal run of venting must have ¼” rise for every 12” of horizontal run.

WARNING

Never run the vent pipe level or downward. This may cause excessive temperatures which could cause a fire.

FOR VERTICAL TERMINATION

Measure the distance from the Horizontal Vent Center Line (see diagram on page 8). Add the ceiling thickness, the vertical rise in an attic or second story, and allow for sufficient vent height above the roofline.

NOTE:

You may use two 45 elbows in place of a 90 elbow. You must follow rise to run ratios when using

45 elbows. The appliance is approved for use with three 90 elbows maximum of a combination of

90 and 45 elbows up to a maximum of 270 .

For two-story applications, firestops are required at each floor level. If an offset is needed in the attic, additional pipe and elbows will be required.

It is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust. Certain limitations apply to vent configurations and must be strictly followed.

INSTALLING A VENT SYSTEM IN AN OUTSIDE CHASE

A chase is a vertical box like structure built to enclose venting that runs along the outside of a building. A chase is required for such venting.

NOTICE

Treatment of firestops and construction of the chase may vary from building type to building type. These instructions are not substitutes for local building code requirements.

NOTICE

When installing in a chase, you should insulate the chase as you would the outside walls of your home. This is especially important in cold climates. Insulation should be considered a combustible material. Maintain proper clearances to combustibles.

15

VENTING

Install a Simpson Duravent (Or equivalent) wall thimble, part number 46DVA-WT (not supplied by SPARK

MODERN FIRES), where the pipe passes through a wall to retain any insulation in the wall and to maintain proper clearances. If the wall being penetrated is constructed of non-combustible material only (i.e., Masonry block or concrete), the wall thimble is not required; and a hole with zero clearance is acceptable (6 ⅝” hole).

NOTICE:

Venting terminals shall not be recessed into a wall or siding.

16

VENTING

This SPARK MODERN FIRES Gas Fireplace has been tested and listed for installation with 4” X 6 5/8” M&G

DuraVent GS/Pro®, Selkirk Direct-Temp®, Security Secure Vent™, AmeriVent Direct™, Metal Fab Direct

Vent and ICC EXCELDirect venting components. Although you may use the pipe components (straight pipe, elbows, etc.) from any of the listed manufacturers, you may only use the vent terminations (caps) listed in the chart on the following page. For installations where a snorkel is needed, please note that only three snorkels are approved for use. Please plan your installation accordingly.

For all specific venting installation requirements, follow the installation instructions included by the venting manufacturer with the venting system components you have chosen.

PLEASE NOTE:

It is assumed that the installation will include at least one 90° elbow. Up to three additional 90° elbows (or equivalent 45° elbows) may also be used. The total venting may not exceed 30 feet of vertical rise and/or 12 feet horizontal run. Refer to the venting charts on pages 16 for specific details while you plan your installation. Note: The number of elbows impacts the maximum allowable horizontal vent run.

There should be a 1 1/2” overlap of the vent and combustion air tubes, when telescopic joints are used.

The location of the vent termination must meet the requirements of the current edition of ANSI

Z223.1/NFPA 54, National Fuel Gas Code or CAN B419.1, Natural Gas and Propane Installation

Code and the requirements shown on page 14 of this manual.

APPROVED VENT

TERMINATIONS

VERTICAL CAP

HORIZONTAL CAP

M&G DURAVENT

GS/PRO

46DVAVCH

46DVAHC

46DVAHRCS

46DVAHSC

SELKIRK DIRECT-

TEMP

1604802

1604804

SECURITY

SECURE VENT

SV4CGC

SV4GHC

AMP AMERIVENT

DIRECT

4DVC

4DVHC

METAL FAB

DIRECT VENT

4DVT

4DHT

ICC EXCELDIRECT

TM4VT

TM4HT

TM4DHT

SNORKEL

N/A 1604836 N/A 4D36C N/A TMST36

Just as with any other vented device, vertical vent rise creates draft (negative pressure) in the firebox as the exhaust gases heat up. If this draft becomes excessive, it can affect the performance or appearance of the fire. The SPARK MODERN FIRES Gas Fireplace includes an integrated air restrictor that can used to balance the draft in the fireplace to the optimal level for installations where excessive draft might occur.

The SPARK MODERN FIRES Gas Fireplace will ship from the factory with the air restrictor set to the #1 position. If the licensed fireplace installer determines that draft reduction is necessary, loosen the fastener on the dial and make small adjustments from #1 to #4 until a satisfactory result has been achieved.

The air restrictor dial is located on the flue side of the firebox when viewed from the front. To access, remove the lower air screen and side panels. Once satisfied with the air restrictor adjustment, secure its position by tightening all hardware.

17

VENTING

SPARK MODERN FIRES flue restrictor kit, part #11317

Some vent configurations may create excess draft within the fireplace. Excess draft can cause issues such as a rapid, or “nervous” flame picture, undesirable flame color, or pilot lifting which may prevent the fireplace from staying lit. In these circumstances it may be necessary to install the flue restrictor kit part #11317 in the venting system. It is permissible to install this restrictor at the vent cap should the venting system already be installed. Secure the restrictor plate with the included #10 sheet metal screws.

Vent chart for 512 VU-THRU and 612 VU-THRU .

Power vent runs of up to 110ft with (6) 90 elbows are permitted when using the SPARK MODERN

FIRES power vent kit PV-800HZ. Refer to power vent instructions for additional power vent installation and operation information.

18

VENTING

Use this worksheet to determine the equivalent horizontal run for use with the vent charts on the next page. The information contained within this worksheet may also be useful during installation or in the event that you need technical assistance from SPARK MODERN FIRES.

A. FUEL TYPE

O

NATURAL GAS

O

LP GAS (PROPANE)

B. TOTAL VERTICAL VENT RISE (MEASURED FROM HORIZONTAL CENTERLINE OF VENT OPENING ON

THE BACK OF THE FIREPLACE TO THE HORIZONTAL CENTERLINE OF THE VENT CAP (FOR

HORIZONTAL VENT CAPS) OR TO THE FLANGE ON THE CAP (FOR VERTICAL CAPS): _____________

FEET

C. TOTAL HORIZONTAL VENT RUN (MEASURED FROM THE VENT STARTER ON THE FIREPLACE TO THE

FLANGE ON THE CAP (FOR HORIZONTAL CAPS) OR TO THE VERTICAL CENTERLINE OF THE CAP

(FOR VERTICAL CAPS)): _____________ FEET

NOTE: THE VERTICAL VENT RISE AND HORIZONTAL VENT RUN ARE THE OFFSETS IN THE LOCATIONS OF

VENT CAP RELATIVE TO THE VENT OPENING ON THE FIREPLACE. VENT PIPE THAT RUNS AT 45° HAVE

BOTH A VERTICAL RISE AND HORIZONTAL RUN. SNORKEL CAPS HAVE BUILT-IN VERTICAL RISE THAT

MUST BE COUNTED.

D. TOTAL NUMBER OF 90° ELBOWS: _______ NOTE: SNORKELS COUNT AS 2- 90° ELBOWS

E. TOTAL NUMBER OF 45° ELBOWS: _______

HORIZONTAL VENT RUN EQUIVALENT CALCULATOR

C. Total horizontal vent run (actual):

D. 90 Elbows needed:

E. 45 Elbows needed:

F. Total 90 Elbows equivalent:

G. 90 Elbows in excess or 2:

D+(Ex½)

F-2

H. Additional horiz. feet (equivalent): Gx3

I. Horizontal vent run (equivalent): C+H

__________

__________

__________

=_________

=_________

=_________

=_________

TERMINATION (CAP) TYPE: O HORIZONTAL

O

VERTICAL

O

SNORKEL

VENT BRAND:

O

Simpson DuraVent GS/PRO®

O

AmeriVent Direct™

O

O

Selkirk Direct-Temp®

Metal Fab Direct Vent

O

O

Security Secure Vent™

ICC Direct Vent

VENT CAP MODEL NO: ____________ NOTE: SEE APPROVED VENT CAPS ON THE PREVIOUS PAGE.

WAS THE FIREPLACE INSTALLED WITH A SPARK MODERN FIRES POWER VENT? (CIRCLE ONE) Y N

19

FINAL ASSEMBLY

SCREEN REMOVAL:

1.

Lift up on the lower air panel to remove it from the fireplace opening.

4.

Allow the screen to rest in the fireplace opening, confirm that the latches are in their “home” position.

2.

Remove the left and right side panels by lifting up and toward you.

5.

Lift the screen up so that the bottom of the screen clears the bottom of the fireplace opening.

3.

The fireplace screen is held in place by 3 self-tensioning latches along its top edge

(4 latches on the 612). Release these latches to remove the screen.

6.

Angle the screen toward you from the bottom to remove.

To reinstall the screen, reverse these steps.

Remember to confirm the latches are in their

“home” position any time you are installing or removing the screen.

NOTICE

If this screen is removed for servicing this appliance it must be replaced prior to operating the appliance.

20

FINAL ASSEMBLY

FINAL ASSEMBLYGLASS REMOVAL:

1. With the screen removed, loosen the ¼-

20 bolts along the top edge of the glass frame using a 7/16 socket.

4. Angle the glass assembly toward you from the bottom to remove.

Refer to the next page for instructions on burner media placement.

2. Confirm that the Screen latches are in their “home” position. (see image

3. Lift the glass frame assembly up so that the bottom of the glass frame assembly clears the bottom of the fireplace opening.

GLASS INSTALLATION:

1. Insert the glass frame assembly into the fireplace by angling the top of the glass in and up into the fireplace.

NOTICE

Do not attempt to operate the fireplace without the screen or glass frame assembly in place. Doing so could lead to injury, property damage, or loss of life.

2. Lift the glass frame assembly up so that the bottom of the glass frame assembly clears the bottom of the fireplace opening.

3. Slide the glass frame into the glass frame retainer along the bottom of the firebox opening.

4. Install the ¼-20 bolts along the top edge of the glass frame assembly and tighten using a 7/16 socket.

21

FINAL ASSEMBLY

PLACING THE BURNER GLASS MEDIA

The burner glass media poly-bag that you set aside when you unpacked the fireplace contains the correct amount of glass material to cover the burner. DO NOT add any additional media to the media supplied with your fireplace. The entire contents of the bag should be evenly distributed over the burner tray.

1.

Locate the burner in the fireplace. Refer to the adjacent illustration.

5. Carefully clip one corner of the poly-bag to form a pouring spout. The opening should be large enough to allow the glass media to flow but not so large that you can’t control the flow.

6. You will notice that the burner surface is designed with turned-up edges that form a tray to hold the glass media.

7. Starting at one end, pour the glass media onto the burner tray, keeping the pouring spout on the poly-bag toward the center of the burner to avoid spillage of glass pieces over the sides of the burner. See the adjacent illustrations.

8. Once you have poured all of the glass burner media into the burner tray, carefully smooth the glass pieces out so they have a uniform depth over the entire surface of the burner. When the burner glass media is properly placed, it should look like the adjacent illustrations.

Note: If a few pieces of glass escape over the edges of the burner tray during installation, it is not a problem. They will simply land in the area below the burner and will do no harm.

22

LIGHTING & OPERATION

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

When lighting this appliance, follow these instructions exactly.

A. This appliance is equipped with an ignition device that automatically lights the pilot. Do not try to light the pilot by hand.

B. BEFORE OPERATING THE BURNER SYSTEM, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light the appliance.

• Do not touch any electric switch; do not use any telephone in your building.

• Immediately call your gas supplier from a neighbor’s telephone. Follow the gas supplier’s instructions

• If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to operate the gas controls. Never use tools. If a knob will not push in or turn by hand, don’t try to re-pair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water.

OPERATING INSTRUCTIONS

1. STOP! Read the safety information above on this label.

9. This appliance is equipped with an ignition device that automatically lights the pilot. Do not try to light the pilot by hand.

10. Using the Remote Handset, or the optional Wall Switch, push the “OFF” button until you hear an audible signal to insure the appliance is off.

11. Wait five (5) minutes to clear out any gas. Then smell for gas including near the floor. If you smell gas, STOP! Follow

“B” in the safety information above. If you don’t smell gas, proceed to step 5.

12. Using either the Remote Handset, or the optional Wall Switch, simultaneously press the “ON” and

“High Flame” buttons. An audible signal confirms the start sequence has begun.

13. Continuing beeps confirm the ignition is in process. Once lighting the pilot flame should appear as shown in Fig.2.

Once the pilot is confirmed, the main burner ignites on high.

NOTE: If the pilot does not stay lit after several tries, proceed to step 9.

14. Use the flame height adjustment buttons on either the Remote Handset or the optional Wall Switch to adjust the flame. Press the button twice to decrease the flame height to its lowest setting, press the button twice to increase flame height to the highest setting. Pressing the or button once will modulate the flame to intermediate settings. The Remote Handset can also be used to control the appliance thermostatically.

15. Press and hold the button on the Remote Handset or optional Wall Switch to set the appliance to Pilot flame only.

16.

If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO THE APPLIANCE” and call your gas service technician or gas supplier.

TO TURN OFF GAS TO THE APPLIANCE

1. To turn off gas to the appliance, push and release the “OFF” button on either the Remote

Handset or the optional Wall

Switch. An audible signal will confirm.

17.

TO TURN OFF THE GAS SUPPLY

TO THE APPLIANCE, close the shut-off valve on the gas supply line to the appliance.

23

LIGHTING & OPERATION

OPERATING YOUR FIREPLACE FOR THE FIRST TIME

When operating your new fireplace for the first time, some vapors may be released due to the curing compounds used in the manufacture of the appliance. They may cause a slight odor and could cause the flames to be the full height of the firebox, or even slightly higher, for the first few hours of operation.

It is also possible that these vapors could set off and smoke detection alarms in the immediate vicinity.

These vapors are quite normal on new appliances. We recommend opening a window to vent the room during the burn off period. After a few hours use, the vapors will have disappeared and the flames will be at their normal height.

FLAME SUPERVISION DEVICE

For your safety, this appliance is fitted with a flame supervision device which will shut-off the gas supply if, for any reason, the pilot flame goes out. This device incorporates a fixed probe, which senses the heat from the pilot flame. If the probe is cool, the device will prevent any gas flow unless manually lighting the pilot. See full lighting instructions. Periodically check the pilot and burner flames, comparing them to figure 2 on the preceding page, and the image at the bottom of this page.

LIGHTING, OPERATION, AND RATING

INFORMATION

The Lighting, Operation and Rating information is located on a plate on the RH side of the firebox.

To access the plate, remove the surround and grab the plate and slide it up to read it. There is important information on both sides of the plate.

SERVICING

If any attention is required for your appliance, contact your dealer quoting the model number. It will be helpful if the appliance’s serial number can also be quoted. This number is on the rating plate, which is located under the burner. The replacement parts are shown at the end of this manual. Please always quote the part number and description when requesting spare parts.

FIREPLACE CONTROL DEVICES

There are two ways to control your fireplace.

1. Thermostatic Remote Control (M46-507)

2. Optional Wall Switch (M46-505)

The Thermostatic Remote Control can be programmed to function automatically—see pages 26-31 .

The Wall Switch (optional) can be used to turn the flame on, off, and to increase or decrease the flame height—see M46-505 —Wall Switch Kit.

NOTE: The remote control in the AUTO mode will override the optional wall switch.

24

REMOTE HANDSET OPERATION

SPARK MODERN FIRES REMOTE HANDSET

Please note the images of the remote handset on pages 26-31 of this manual depict the Maxitrol GV60

Remote Control, although the profile of the remote depicted is different from the one included with your fireplace, the buttons and operation of the remote is the same.

Follow the instructions in the manual using these guidelines:

The large flame button as seen in the manual’s images is equivalent to the up arrow on your remote

The small flame button as seen in the manual is equivalent to the down arrow on your remote

GV60 Remote Control shown in this Manual

GV60 Remote Control supplied with your fireplace

SPARK MODERN FIRES REMOTE HANDSET PAIRING

Press and hold the Reset button on the

Receiver mounted within your fireplace.

Initially you will hear a short beep, continue to hold the Reset button until you hear a second longer beep.

Press the down arrow on your remote .

You will hear 2 beeps from the Receiver confirming that your remote is now paired.

25

REMOTE HANDSET OPERATION

HOW TO TURN YOUR FIREPLACE OFF

(INCLUDING PILOT)

Familiarize yourself with each of these methods before operating your fireplace.

Handset and Wall Switch: Press and hold the OFF button for a second (either on the handset or the

wall switch).

If the flames are on, they go down and you hear the valve motor wind down. You hear a clunk and a beep indicating that the valve has received the signal from the remote control.

HOW TO ENSURE YOUR FIREPLACE CANNOT BE TURNED ON INADVERTENTLY

You can use the following method to ensure that your fireplace will not turn on when you don’t want it on.

First, ensure your replace is turned off—including the pilot—and cold BEFORE going ahead.

Close the shut-off valve on the gas supply line to the appliance.

Remove all batteries from the receiver as well as the battery from the handset.

Automatic Shut-Off (in certain conditions)

Your fireplace’s remote control is equipped with an automatic shut-off mechanism which is activated in certain conditions. See page 31 in the Remote Control Operation section for a description of this feature.

NOTE: Before using the remote control system for the first time, the receiver and the handset are

synchronized at the factory. See the section SPARK MODERN FIRES Remote Handset Pairing Set-up on page 25 of this manual if the receiver and handset lose synchronization.

IMPORTANT: BEFORE YOU BEGIN, please note that on this system, the settings of time, temperature and

automatic ON/OFF can only be programmed when the function display is flashing. Be patient when programming as it can take a few seconds to set.

26

REMOTE HANDSET OPERATION

27

REMOTE HANDSET OPERATION

28

REMOTE HANDSET OPERATION

29

REMOTE HANDSET OPERATION

30

REMOTE HANDSET OPERATION

31

GAS CONVERSION

These appliances are field convertible between Propane to Natural gas when a SPARK MODERN FIRES gas conversion kit is used. Gas conversions must be performed by a qualified service technician.

PART # DESCRIPTION SPARK MODERN FIRES CONVERSION KIT CONTENTS

60BI-LPC

60BI-NGC

512 LP CONVERSION KIT

512 NG CONVERSION KIT

#27 PILOT ORIFICE

#35 PILOT ORIFICE

#56 LP BURNER ORIFICE – 2PCS

#49 NG BURNER

ORIFICE – 2PCS

NG COLLAR – 2PCS

#8 SCREW – 2PCS

#8 SCREW – 2PCS

72BI-LPC

72BI-NGC

612 LP CONVERSION KIT

612 NG CONVERSION KIT

#27 PILOT ORIFICE

#35 PILOT ORIFICE

#55 LP BURNER ORIFICE – 2PCS

#46 NG BURNER

ORIFICE – 2PCS

NG COLLAR – 2PCS

#8 SCREW – 2PCS

#8 SCREW – 2PCS

Before servicing the appliance, shut off gas and electrical power to the unit. To access the burner(s), follow the screen and glass removal procedure shown on pages 20 and 21 .

3.

4.

1.

2.

5.

6.

7.

The burner(s) are retained by #10 sheet metal screws, using a 5/16” nut driver, remove these screws. (8 screws in the 512; 12 screws in the 612).

The 512 VU-THRU and 612 U-THRU have a burner link that aligns the burners, remove the (2) #10 sheet metal screws.

Lift off the pilot hood.

The Pilot assembly is retained by (2) #10 sheet metal screws.

After removing the screws retaining the pilot assembly, lift the pilot assembly into the firebox.

Using a 10mm wrench, remove the pilot gas line to swap the orifice.

Once the pilot gas line is tight, reinstall the pilot assembly making sure the gasket is intact.

32

GAS CONVERSION

8. When converting from Propane to Natural Gas, slide the

NG Collar over the Burner inlet tube and use a ¼” nut driver to secure with a #8 sheet metal screw.

9. When converting from Natural Gas to Propane, remove the

NG Collar from the burner inlet tube.

10. Using a 9/16” deep socket, replace the burner orifice(s) in the firebox with those provided in the conversion kit.

11. Reinstall the burner(s) in the fireplace. Reinstall the burner link if required.

12. Using a flat screw driver, remove the Pressure Conversion

Plug and set it to NG or LP accordingly.

Gas Flow Adjustment

1.

2.

3.

Install a gas pressure gage on the outlet pressure tap on the valve.

Light the fireplace using the remote handset.

With the fireplace on high, set the maximum pressure by adjusting the small flat screw set within the Pressure

Conversion Plug. Refer to chart below for high pressure settings. (it may be necessary to lift the valve control bracket up out of the fireplace to access the pressure tap and minimum rate orifice)

4.

5.

6.

double tap the down arrow to set the fireplace to low. “Lo” will momentarily appear on the display.

The minimum rate can be set by adjusting the minimum rate orifice. Refer to the chart below for Low pressure settings.

Close the pressure tap(s) by turning the screws clockwise.

Check all connections/pressure taps for leaks.

NG  Collar  

MODEL

512 VU-THRU

612 VU-THRU

HIGH PRESSURE (NG)

3.9” w.c. / 1.0kPa

3.9” w.c. / 1.0kPa

LOW PRESSURE (NG)

1.9” w.c. / 0.47kPa

2.2” w.c. / 0.55kPa

HIGH PRESSURE (LPG)

10.0” w.c. / 2.5kPa

10.0” w.c. / 2.5kPa

LOW PRESSURE (LPG)

4.7” w.c. / 1.17kPa

4.7” w.c. / 1.17kPa

33

MAINTENANCE

ANNUAL MAINTENANCE

A qualified service agency should conduct an annual inspection and maintenance of your SPARK

MODERN FIRES Gas Fireplace including the overall installation and venting to keep it running safely. The following procedures should be per-formed only by a qualified service person. The gas supply should be turned off and the stove should be completely cool whenever a maintenance procedure is performed.

All parts of the appliance that are removed for servicing must be replaced prior to operation.

This appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive dust or lint from carpeting, bedding materials, pets, etc. It is imperative that control compartments and circulating air passageways of this appliance be kept clean.

CLEANING THE BURNER AND FIREBOX

During the annual inspection and maintenance appointment, the service person should clean the burner and firebox. To gain access to the firebox and burner, follow the instructions beginning on page

18 of this manual.

DO NOT USE A VACUUM CLEANER TO CLEAN THE GLASS BURNER MEDIA.

A vacuum cleaner may be used to clean the metal parts of the firebox. Leave the glass burner media in place. Use a soft brush to clean the burner glass media. If the burner media does need to be removed, carefully scoop it off the burner and avoid dropping glass pieces in the air gaps around the burner.

Follow the instructions on page 22 of this manual when replacing the burner media on the burner top.

AIR FLOW

The SPARK MODERN FIRES Gas Fireplace utilizes a convection air heat exchange system to maximize heat delivered from the fireplace. It is important that air flows freely through the convection air system and out the air grills. Do not place objects against the fireplace that will block the convection air inlet flow or in front of any air outlet.

CLEANING THE GLASS AND GLOSS BLACK ENAMEL PANELS

After allowing the Fireplace to cool, use an ammonia-free glass cleaner and a soft, clean cloth to clean the Enamel Panels at the rear and side of the firebox. It is recommended that the Glass Enamel Panels be cleaned at least annually to avoid discoloration. More frequent cleaning may be required if contaminants are present in the gas supply or general atmosphere.

WARNING: Never clean the Glass or Enamel Panels while they are hot. Do not use abrasive cleaners or

cleaners containing ammonia.

NOTE: It is recommended that a Micro-fiber cleaning cloth be used to clean the glass and enamel

panels.

34

MAINTENANCE LOG

We strongly recommend that you keep a log of the regular maintenance that is performed on your fireplace. We have provided the forms below to make it easy. Simply ask your qualified service per-son to fill out one of the maintenance record forms below, each time the fireplace is serviced. This will help insure that all of the required maintenance procedures have been completed, at least annually. Regular maintenance will help keep the fireplace functioning in a safe and reliable manner. Additional forms are available from your installer or service person when needed.

35

MAINTENANCE LOG CONT.

36

REPLACEMENT PARTS LIST

GENERAL REPLACEMENT PARTS

PART NAME P/N

Natural Gas (NG) Pilot Assy.

Propane (LP) Pilot Assy.

Receiver Module (Maxitrol)

Wall Switch Panel (Optional)

BI-401

BI-402

M46-504

M46-505

Remote Handset (Maxitrol) M46-507

Module for Additional Function 36-560

PART NAME P/N

TC Line Red

TC Line Yellow

M46-701

M46-702

Thermocouple Interrupter Block M46-703

8-Wire Connecting Cable M46-704

Gas Valve (Maxitrol)

Replacement Blower

M46-515

36-531

512 VU-THRU - REPLACEMENT PARTS

PART NAME P/N PART NAME

Burner Orifice (NG)

Burner Orifice (LP) LPBI-60

Burner Glass Media (Clear/Mixed) 60BI-200

Burner Conversion Kit (NG)

NGBI-60 Firebox Enamel Panel - End

Burner Module (NG) (2 req.)

Burner Module (LP) (2 req.)

60BI-NGC Burner Conversion Kit (LP)

P/N

60BI-201

60BI-301

60BI-302

60BI-LPC

612 VU-THRU - REPLACEMENT PARTS

PART NAME P/N PART NAME

Burner Orifice (NG)

Burner Orifice (LP)

NGBI-72

LPBI-72

Firebox Enamel Panel - Center

Burner Module (NG) (2 req.)

Burner Glass Media (Clear/Mixed) 72BI-200

Burner Conversion Kit (NG) 72BI-NGC

Burner Module (LP) (2 req.)

Burner Conversion Kit (LP)

P/N

72BI-201

72BI-301

72BI-302

72BI-LPC

37

CONTROL SCHEMATIC

Caution: Label all wires prior to disconnection when servicing the controls. Wiring errors can cause

improper and dangerous operation. Verify proper operation after servicing.

For replacement parts and customer service contact your SPARK MODERN FIRES dealer or:

SPARK MODERN FIRES

99B  Greenwood  Ave  

Bethel,  CT  06801  

(T) 203-791-2725

[email protected]

3

8

INSTALLATION RECORD

The installer should complete the form below that describes the details of the installation. Having this written record of installation information available will greatly expedite trouble-shooting should any problem arise with your stove. The installer should keep a duplicate of this form for their records.

Date Purchased:

Dealer:

Date Installed:

Installer:

Fireplace Model: (circle one)

Serial Number:

Fuel: (circle one)

Inlet Pressure (after installation):

Manifold Pressure (after Installation):

_____________________________________________

_____________________________________________

_____________________________________________

_____________________________________________

512 612

_____________________in. WC

Natural Gas (NG) Propane (LP)

_____________________________________________

High Fire: _____________ in. WC

Low Fire: _____________ in. WC

Altitude: (feet above sea level)

Was the stove de-rated? (circle one)

_____________________________________________

Yes No

If the stove was de-rated, to what orifice size? _____________________________________________

Other installation notes: _____________________________________________

____________________________________________________________________________

____________________________________________________________________________

____________________________________________________________________________

____________________________________________________________________________

____________________________________________________________________________

____________________________________________________________________________

39

WARRANTY INFORMATION

KEEP THIS FOR WARRANTY

Model  _________________________  

Serial  No.  ______________________  

Date  Purchased  _________________  

Always specify model and serial numbers when communicating with the factory

.  

LIMITED LIFETIME WARRANTY

The following components are warranted for life to the original owner, subject to proof of purchase:

Firebox, Combustion Chamber, and Steel Burner.

BASIC WARRANTY

Spark Modern Fires warrants the components and materials in your gas appliance to be free from manufacturing and material defects for a period of two years from date of installation. After installation, if any of the components manufactured by Spark Modern Fires in the appliance are found to be effective in materials or workmanship, Spark Modern Fires will, at its option, replace or repair the defective components at no charge to the original owner. Spark Modern Fires will also pay for reasonable labor cost incurred in replacing or repairing such components for a period of two years from date of installation. Any products presented for warranty repair must be accompanied by a dated proof of purchase.

This Limited Lifetime Warranty will be void if the appliance is not installed by a qualified installer in accordance with installation instructions. The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance, and does not extend to (1) firebox/burner assembly damaged by accident, neglect, misuse, abuse, alterations, negligence of others, including the installation thereof by unqualified installers, (2) the costs of removal, reinstallation or transportation of defective parts on the appliance, or (3) incidental or consequential damage.

All service work must be performed by an authorized service representative.

This warranty is expressly in lieu of other warranties, express or implied, including the warranty of merchantability of fitness for purpose and of all other obligations or liabilities. Spark Modern Fires does not assume for it any other obligations or liabilities in connection with sale or use of the appliance. In states that do not allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damage, those limitations of exclusions may not apply to you. You may also have additional right not covered in the Limited Lifetime Warranty. Spark Modern Fires reserves the right to investigate any and all claims against this Warranty and decide upon method of settlement. For information about this warranty, contact:

Spark  Modern  Fires  

99B  Greenwood  Ave  

Bethel,  CT  06801  

203-­‐791-­‐2725   [email protected]  

Rev.  11/2016  

40

RECORD YOUR PRODUCT INFORMATION

Model #:___________________________ Serial #______________________

Date Purchased:____________________ Date Installed___________________

41

V1 / 11/1/2016