data sheets

Add to My manuals
14 Pages

advertisement

data sheets | Manualzz

TABLE OF CONTENTS

HWG Portable

HWG 200 - 30

HWG 200 - 46

HWG 250 - 40

HWG 250 - 60

HWG

HWG 180/6K - 34

HWG 220/6K - 49

HWG 300/8K - 54

HWG 400/10K - 79

Click the models to navigate the Data sheets.

DATA SHEETS

HYDRAULIC WELDING GENERATORS SYSTEM

DATA SHEET

HWG HYDRAULIC WELDING GENERATOR

HWG 200 - 30

HWG 200 - 46

HWG 250 - 40

HWG 250 - 60

HWG HYDRAULIC WELDING GENERATOR

DATA SHEET

DIMENSIONS

L

H

A B

E E

L

MODEL

HWG 200-30

L

360

(14.2)

HWG 200-46

HWG 250-40

360

(14.2)

360

(14.2)

HWG 250-60

360

(14.2)

E

A

HYDRAULIC PORTS

B

C

W

W

205

(8.1)

205

P

H

T

205

(8.1)

205

(8.1)

DIMENSIONS, mm (in)

H

275

(10.8)

A

240

(9.4)

B

99

(3.9)

275

(10.8)

275

(10.8)

275

(10.8)

240

(9.4)

240

(9.4)

240

(9.4)

C

W

99

(3.9)

99

(3.9)

99

(3.9)

C

159

(6.3)

159

(6.3)

159

(6.3)

159

(6.3)

E

Ø9

(0.4)

Ø9

(0.4)

Ø9

(0.4)

Ø9

(0.4)

WEIGHT kg (lbs)

18

(40)

18

(40)

19

(42)

19

(42)

T

P

2

MODEL

HWG 200-30

HWG 200-46

HWG 250-40

HWG 250-60

PRESSURE LINE

P

BSB 1/2”

BSB 1/2”

BSB 1/2”

BSB 1/2”

RETURN LINE

T

BSB 1/2”

BSB 1/2”

BSB 1/2”

BSB 1/2”

Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com

HWG HYDRAULIC WELDING GENERATOR

DATA SHEET

TECHNICAL SPECIFICATIONS

HWG 200

30

HWG 200

46

HWG 250

40

HWG 250

60

OUTPUT CHARACTERISTICS

Welding current

Welding electrode

Welding current adjustment

Load duty

ADC mm

ED

Arc striking voltage VDC

Welding voltage VDC

Voltage control

Welding cables mm 2 /m

AUXILIARY ELECTRICITY

Power kW

Voltage VDC

Socket 2P+PE 10A

IP class

HYDRAULIC POWER REQUIREMENTS

Flow min.

Flow max.

Pressure at nominal power output l/min

(gpm) l/min

(gpm) bar

(psi)

Pressure max.

bar

(psi)

HYDRAULIC FLUID REQUIREMENTS

Viscosity cSt

Temperature °C (°F)

Filter ratio um

Cooling capacity requirements kW

Gallons are U.S. liquid gallons

* Depending on the hydraulic fluid.

40-200

Ø 2,5 - 4

60%/200

30-200

Ø 2,5 - 4

60-250

Ø 2,5 - 4

Continuous regulator

60%/200 40%/250

60-250

Ø 2,5 - 4

40%/250

100%/133A 100%/133 A 95%/ 166 A 95%/ 166 A

60 VDC

22-32

60 VDC

22-32

65 VDC

22-32

Automatic/ Electronic

35 / 5

65 VDC

22-32

37

(9.77)

55

(14.52)

190

(2756)

200

(2901)

1,5

50

(13.2)

68

(17.95)

140

(2031)

200

(2901)

2,0

220

1 pcs

34

42

(11.09)

69

(18.22)

190

(2756)

180

(2611)

10-200 / optimum 25-35 max. 70 (158)*

1,5

25 or better

2

62

(16.37)

80

(21.12)

140

(2031)

150

(2176)

2

Other options available by request.

Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com

3

DATA SHEET

HWG HYDRAULIC WELDING GENERATOR

HWG 180/6K-34

HWG 220/6K-49

HWG HYDRAULIC WELDING GENERATOR

DATA SHEET

DIMENSIONS

L

H

L

E

A

MODEL

HWG 180/6K-34

HWG 220/6K-49

E

L

563

567

E

A

HYDRAULIC PORTS

B

W

E

C

W

H

365

370

(14.6)

A

338

(13.3)

338

(13.3)

B

171

(6.7)

175

(6.9)

C

F

160

(6.3)

160

(6.3)

C

B

110

(4.3)

110

(4.3)

E

Ø12

(0.5)

Ø12

(0.5)

WEIGHT kg (lbs)

51

(112)

52

(115)

B

C

W

P

T

MODEL

HWG 180/6K-34

HWG 220/6K-49

PRESSURE LINE

P

BSB 1/2”

BSB 1/2”

RETURN LINE

T

BSB 1/2”

BSB 1/2”

2 Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com

HWG HYDRAULIC WELDING GENERATOR

DATA SHEET

TECHNICAL SPECIFICATIONS

HWG 180/6K-34 HWG 220/6K-49

OUTPUT CHARACTERISTICS

Welding current

Welding electrode

Welding current adjustment

Load duty

ADC

ED

Arc striking voltage VDC

Welding voltage VDC

Welding cables mm 2 /m

AUXILIARY ELECTRICITY

1-phase*

3-phase

Socket 2P+PE 16A

Socket 3P+N+PE 16A

IP class

HYDRAULIC POWER REQUIREMENTS

Flow min.

Flow max.

Pressure at nominal power output l/min

(gpm) l/min

(gpm) bar

(psi)

Pressure max.

bar

(psi)

HYDRAULIC FLUID REQUIREMENTS

Viscosity cSt

Temperature °C (°F)

Filter ratio um

Cooling capacity requirements kW

40-180 ADC 30-220 ADC

Ø 4 mm Ø 5 mm

Selector switch

2 x 7 positions 3 x 7 positions

50%/180 A 35%/220 A

100%/110A

73 VDC

21,5 - 28,8

230 VAC / 3,0 kVA

400 VAC / 6,0 kVA

1 pcs

1 pcs

23

36 (5.5)

53 (14.00)

190

(2800)

210

(3000)

1,5

35 mm 2 / 5m

60%/170 A

73 VDC

21,5 - 28,8

230 VAC / 3,5 kVA

400 VAC / 6,5 kVA

1 pcs

1 pcs

51 (13.5)

68 (17.95)

(2200)

(3000)

10-200 / optimum 25-35 max. 70 (158)**

25 or better

Gallons are U.S. liquid gallons

* Nominall current 1~phase / 3~phase /phase must not exede maximum load.

** Depending on the hydraulic fluid.

23

155

210

1,5

Other options available by request.

Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com

3

DATA SHEET

HWG HYDRAULIC WELDING GENERATOR

HWG 300/10K-54

HWG HYDRAULIC WELDING GENERATOR

DATA SHEET

DIMENSIONS

L

H

E

MODEL

A

HWG300/10K-54

L

E

B

C

W

L

613

(24.15)

W

285

(11.15)

H

434

(17.10)

A

344

(13.5)

B

184

(7.2)

C

200

(7.9)

E

Ø12

(0.5)

WEIGHT kg (lbs)

92

(203)

B

P

T

C

W

MODEL

HWG300/10K-54

P

T

PRESSURE LINE

P

BSB 3/4”

RETURN LINE

T

BSB 3/4”

2 Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com

HWG HYDRAULIC WELDING GENERATOR

DATA SHEET

TECHNICAL SPECIFICATIONS

HWG300/10K-54

OUTPUT CHARACTERISTICS

Welding current

Welding electrode

Welding current adjustment

Load duty

ADC

ED

40-300 ADC

Ø 6 mm

Continuous regulator

3x 12 positions

35%/300 A

60%/ 250 A

Arc striking voltage VDC

Welding voltage VDC

Welding cables mm 2 /m

AUXILIARY ELECTRICITY

70 VDC

21,5 - 32

35 mm 2 / 5m

1-phase*

3-phase

Socket 2P+PE 16A

Socket 3P+N+PE 16A

IP class

HYDRAULIC POWER REQUIREMENTS

Flow min.

Flow max.

Pressure at nominal power output

Pressure max.

l/min

(gpm) l/min

(gpm) bar

(psi) bar

(psi)

230 VAC / 4,0 kVA

400 VAC / 8,0 kVA

1 pcs

1 pcs

23

56

(14.8)

88

(23.25)

175

(2500)

210

(3000)

HYDRAULIC FLUID REQUIREMENTS

Viscosity cSt

Temperature °C (°F)

Filter ratio um

10-200 / optimum 25-35 max. 70 (158)**

25 or better

2,5 Cooling capacity requirements kW

Gallons are U.S. liquid gallons

* Nominall current 1~phase / 3~phase /phase must not exede maximum load

** Depending on the hydraulic fluid.

Other options available by request.

Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com

3

DATA SHEET

HWG HYDRAULIC WELDING GENERATOR

HWG 400/10K-79

DIMENSIONS

L

HWG HYDRAULIC WELDING GENERATOR

DATA SHEET

L

H

E

A

E

B H C

W

MODEL

HWG400/10K-79

E

A

L

801

(31.55)

E

HYDRAULIC PORTS

W

318

(12.55)

DIMENSIONS, mm (in)

H

544

(21.45)

B P

A

382

(15.0)

B

308

(12.1)

T

C

220

(8.7)

E

Ø14

(0.6) C

W

WEIGHT kg (lbs)

132

(291)

P

T

MODEL

HWG400/10K-79

PRESSURE LINE

P

BSB 3/4”

RETURN LINE

T

BSB 1”

2 Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com

HWG HYDRAULIC WELDING GENERATOR

DATA SHEET

TECHNICAL SPECIFICATIONS

HWG400/10K-79

OUTPUT CHARACTERISTICS

Welding current

Welding electrode

Welding current adjustment

ADC 30-400 ADV

Ø 7 mm

Selector switch

10 - 100%

35% / 400 A Load duty ED

Arc striking voltage VDC

Welding voltage VDC

Welding cables mm 2 /m

AUXILIARY ELECTRICITY

70 VDC

22 - 36

35 mm 2 / 5m

1-phase*

3-phase

Socket 2P+PE 16A

Socket 3P+N+PE 16A

IP class

HYDRAULIC POWER REQUIREMENTS

Flow min.

Flow max.

Pressure at nominal power output

Pressure max.

l/min

(gpm) l/min

(gpm) bar

(psi) bar

(psi)

230 VAC / 4,0 kVA

400 VAC /10,0 kVA

1 pcs

1 pcs

23

81

(21.4)

101

(26.7)

200

(2900)

210

(3000)

HYDRAULIC FLUID REQUIREMENTS

Viscosity cSt

Temperature °C (°F)

Filter ratio um

10-200 / optimum 25-35 max. 70 (158)**

25 or better

3 Cooling capacity requirements kW

Gallons are U.S. liquid gallons

* Nominall current 1~phase / 3~phase /phase must not exede maximum load

** Depending on the hydraulic fluid.

Other options available by request.

Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | [email protected] | www.dynaset.com

3

Menotie 3

FI-33470 Ylöjärvi, Finland tel: +358 3 3488 200 [email protected]

ELECTRICITY

HG Hydraulic Generator

HGV Variable Hydraulic Generator

HWG Hydraulic Welding Generator

HGG Hydraulic Ground Power Generator

MAGNET POWER

HMG Hydraulic Magnet Generator

HMAG Hydraulic Magnet

MAG Lift Magnet

HIGH PRESSURE WATER

HPW Hydraulic High Pressure Water Pump

HPW Hydraulic Power Washer

KPL High Pressure Street Washing Unit

PPL High Pressure Pipe Cleaning Unit

HPW-DUST High Pressure Dust Suppression System

HPW-FIRE High Pressure Firefighting System

FP Fire Fighting Piercing Kit

HDF Hydraulic Drilling Fluid Pump

JPL High Pressure Bin Washing System

HSP Hydraulic Submersible Pump

VIBRATION

HVB Hydraulic Vibra

HVD Hydraulic Directional Vibra

P

POWER BOOSTING

HPI Hydraulic Pressure Intensifier

HPI-C Hydraulic Pressure Intensifier for Cylinder

COMPRESSED AIR

HK Hydraulic Compressor (piston)

HKL Hydraulic Rotary Vane Compressor

HKR Hydraulic Screw Compressor

KNOW-HOW

HHK Hydraulic Grinder

HV/HVY Hydraulic Winch / Winch Unit

Hydraulic Power Take-off (PTO)

Hydraulic Power Unit Technology

De-Icing Technology

Installation Valves

www.dynaset.com

advertisement

Related manuals