Sophos SG 310 Operating Instructions Manual
Sophos SG 210 is a high-performance security appliance that provides advanced protection for your network. It features six 10/100/1000 Base-TX ports, two optional FleXi Port modules, two SFP ports, two USB ports, and a VGA port. With its powerful hardware and comprehensive security features, the SG 210 is ideal for small businesses and branch offices.
Reklama
Reklama
Operating Instructions
SG 210/230/310/330
Operating Instructions
Foreword
We are pleased to welcome you as a new customer of our Sophos SG appliances.
To install and configure the hardware appliance you can use the following documents:
Ì Hardware Quick Start Guide: Connection to the system peripherals in a few steps
Ì Operating Instructions: Notes on the security and commissioning of the hardware appliance
Ì Administration Guide: Installing and configuring the software appliance
The Hardware Quick Start Guide and the Security Notes are also delivered in printed form together with the hardware appliance. The instructions must be read carefully prior to using the hardware and should be kept in a safe place.
You may download all user manuals and additional documentation from the support webpage at: sophos.com/support
Security Symbols
The following symbol and its meaning appears in the Hardware Quick Start Guide,
Security Notes and in these Operating Instructions.
Caution and Important Note. If these notes are not correctly observed:
Ì This is dangerous to life and the environment
Ì The appliance may be damaged
Ì The functions of the appliance will be no longer guaranteed
Ì Sophos shall not be liable for damages arising from a failure to comply with the security notes
Designed Use
The hardware appliances are developed for use in networks. The SG
210/230/310/330 models may be operated as a standalone appliance. The hardware appliance can be used in commercial, industrial and residential environments.
The SG 210/230/310/330 models belongs to the appliance group A.
The hardware appliance must be installed pursuant to the current installation notes.
Otherwise failure-free and safe operation cannot be guaranteed. The EU declaration of conformity is available at the following address:
Sophos Technology GmbH
Amalienbadstr. 41/Bau 52
76227 Karlsruhe
Germany
SG 210/230/310/330 1
Operating Instructions
SG 210/230 (rev.1)
CE Labeling, FCC and Approvals
The SG 210/230/310/330 appliances comply with FCC Class A, CE, C-Tick, VCCI and UL.
Important Note:
For computer systems to remain CE and FCC compliant, only CE and FCC compliant parts may be used. Maintaining CE and FCC compliance also requires proper cable and cabling techniques.
Operating Elements and Connections
COM Reset
Optional FleXi Port module
SG 310/330 (rev.1)
6* 10/100/1000
Base-TX ports
2* USB
LED: Power
Hard Disk
2* 10/100/1000
Base-TX ports
2* SFP ports
COM Reset
LCD and control keys
Optional FleXi Port module
SG 2xx/3xx (rev.1)
Power switch
6* 10/100/1000
Base-TX ports
2* USB
LED: Power
Hard Disk
LCD and control keys
Power Connector USB Fans
SG 210/230/310/330
VGA
2
Operating Instructions
SOPHOS
Protection
UTM 9.xxx
10 days 01:43:17
CPU xx% xx% yy% zz%
RAM x% y GB
SWAP x% y GB all in x kbits/sec out y kbits/sec
Controls
Power (LED Display)
Green
Red
LEDs on each Ethernet connector
ACT/LNK Green Constantly
Speed
(RJ45 ports)
Orange
Green
Speed
(SFP+ ports)
Blue
Orange
Off
Flashing
On
On
Off
On
On
Off
Power on
HDD (Hard disk access)
1. The Ethernet port is receiving power.
2. Good connection between the
Ethernet port and hub.
1. The adapter and switch are not receiving power.
2. No connection between both ends of network.
3. Network drivers have not been loaded or do not function correctly.
The adapter is sending or receiving network data. The frequency of the flashes varies with the amount of traffic.
If ACT/LNK LED is on then this LED shows operating speed at 1000 Mbps
If ACT/LNK LED is on then this LED shows operating speed at 100 Mbps
If ACT/LNK LED is on then this LED shows operating speed at 10 Mbps
If ACT/LNK LED is on then this LED shows operating speed at 10 Gbps
If ACT/LNK LED is on then this LED shows operating speed at 1 Gbps
Ports not operational
LCD and Control Keys
The Sophos SG 210/230/310/330 units have an LCD and an operating unit with four membrane keys. In the LCD, 16 characters per line can be displayed. The display contains in three cycling views information on the hardware and specific system states.
After the security appliance has booted this message is displayed.
Sophos UTM version
Appliance Uptime
CPU load information
Average Load in the last 1, 5 and 15 minutes
Memory usage
Traffic on interface
SG 210/230/310/330 3
Operating Instructions
SG 210/230/310/330
ESC
With the membrane keys three actions can be executed
Ì Change IP Address : This option enables the user to change the interface’s IP address and netmask. All available and enabled IP addresses can be changed.
Ì Reboot machine : The security appliance is rebooted. The reboot action will shut down the system completely and reboot.
Ì Shut down : The security appliance is shut down. The shut down action allows you to turn off the system, and allows you to cleanly stop all running services.
Ì
Factory reset
: All settings are reset to the factory settings. The factory reset function sets all of the configuration settings and options to their original state.
All data entered after the initial installation will be deleted, including the HTTP proxy cache, the entire email queue, accounting and reporting data, passwords, and uninstalled Up2Date packages. The version of the software will not change.
That is, all firmware and pattern updates that have been installed will be retained.
Ì Disable OTP (One Time Password) authentication : The OTP authentication will be disabled for the selected options. This feature only handles webadmin and shell access options if they are enabled.
The keys have the following functions
The current menu is left. When the key is pressed a couple of times, the modifications are discarded and the initial state will be displayed.
Those keys are used to switch between the different menus and/or characters.
ENTER
Pressing executes the configured action.
Change IP Address
1. Press Enter key.
The following message will be displayed: Change IP addr
2. Press Enter key.
The following message will be displayed:
IP address (Ethx) XXX.XXX.XXX.XXX/YY
3. Press up and down keys to select the interface.
4. Press Enter key. The IP address in edit mode with underline cursor is shown.
5. Press up and down keys to change the digit at the underlined cursor position.
6. Press Enter to move to the next right position or press
ESC to leave edit mode without saving.
7. After the last digit is modified press the Enter key.
The following message will be displayed:
Netmask
YY
8. Press up and down keys to increment or decrement the netmask value.
9. Press Enter to save the changed IP address and netmask.
4
Operating Instructions
Starting reboot machine
1. Press the Enter key.
2. Press the ▼ key once.
The following message will be displayed: Reboot Machine
3. Press the Enter key.
The following message will be displayed: Are you sure?
With the up/down keys you can select Yes (y) or No (n).
4. Press the Enter key to confirm your settings.
The reboot machine action will now start.
Starting shut down
1. Press the Enter key.
2. Press the ▼ key twice.
The following message will be displayed: Shutdown
3. Press the Enter key.
The following message will be displayed: Are you sure?
With the up/down keys you can select Yes (y) or No (n).
4. Press the Enter key to confirm your settings.
The shut down action will now start.
Starting factory reset
1. Press the Enter key.
2. Press the ▼ key three times.
The following message will be displayed: Factory Reset
3. Press the Enter key.
The following message will be displayed: All Data Erased! Are you sure?
With the up/down keys you can select Yes (y) or No (n).
4. Press the Enter key to confirm your settings.
The factory reset action will now start.
SG 210/230/310/330 5
Operating Instructions
Disabling OTP (One Time Password) Authentication
1. Press Enter key.
2. Press the ▼ key four times.
The following message will be displayed:
OTP Recovery
3. Press Enter key.
The following message will be displayed:
Disable OTP xxxxxx
If there is no option to disable available the following message will be displayed:
Not Available
4. Press up/down keys to select the feature to disable (if enabled).
5. Press Enter key.
The following message will be displayed:
Disable xxxxx
Are you sure?
6. With the up/down keys you can select Yes (y) or No (n).
7. Press Enter to confirm.
Putting into Operation
Caution : Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
Scope of Supply
The supplied parts are indicated in the Hardware Quick Start Guide.
Mounting Instructions
The SG 210/230/310/330 appliances are designed for use in racks. Please consider the following security tips:
Important Note : Functional reliability outside of a rack cannot be guaranteed.
Warnings and Precautions
The appliance can be operated safely if you observe the following notes and the notes on the appliance itself.
SG 210/230/310/330 6
Operating Instructions
Rack Precautions
Ì Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.
Ì In single rack installation, stabilizers should be attached to the rack.
Ì In multiple rack installations, the racks should be coupled together.
Ì Always make sure the rack is stable before extending a component from the rack.
Ì You should extend only one component at a time—extending two or more simultaneously may cause the rack to become unstable.
General Server Precautions
Ì Review the electrical and general safety precautions that came with the components you are adding to your appliance.
Ì Determine the placement of each component in the rack before you install the rails.
Ì Install the heaviest server components on the bottom of the rack first, and then work up.
Ì Allow the hot plug hard drives and power supply modules to cool before touching them.
Ì Always keep the rack‘s front door, all panels and server components closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ì Ambient operating temperature : If installed in a closed or multiunit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room.
Therefore, you should install the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature.
Ì Reduced airflow : Equipment should be mounted into a rack with sufficient airflow to allow cooling.
Ì Mechanical loading : Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Ì
Circuit overloading
: Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Ì Reliable ground : Reliable grounding must be maintained at all times.
To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e., the use of power strips, etc.).
SG 210/230/310/330 7
Operating Instructions
Rack Mounting Instructions
To mount the appliance to the rack you need the delivered rack-mount brackets.
There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
Important Note : Make sure you use the screws supplied with the rack-mount brackets. Using the wrong screws could damage the hardware appliance and would invalidate your warranty. Please observe the mounting instructions for your rack.
1. Attach the rack-mount brackets to the appliance
Place the appliance on a hard, flat surface with the front panel facing you.
Attach the rack–mount brackets to the left and right side of the appliance with the supplied screws.
Make sure the brackets are properly attached to the appliance.
2. Choose the rack location
Leave enough clearance in front of the rack so that you can open the front door completely (~60 cm/25 inches).
Leave approximately 80 cm/30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing.
This product is for installation only in a restricted access location (no capitalization) (dedicated equipment rooms, service closets and the like).
3. Slide the appliance into the rack.
4.
Attach the brackets to the rack with the appropriate screws (not included).
Connection and Configuration
How to connect the appliance is described in the Hardware Quick Start Guide. For configuration you can follow the initial setup wizard described in the WebAdmin
Quick Start Guide or cancel it and perform a manual setup (see the Sophos UTM
Administration Guide).
SFP GBIC ports
The SG 210/230/310/330 models provide the option to add Sophos FleXi Port network modules with SFP (1 GbE) or SFP+ (1/10GbE) GBIC Ports. The abbreviation
SFP GBIC stands for small form-factore plugable GigaBit interface converter, a flexible interface which changes electronic signals into optical signals. The converters used with the appliance are often also called Mini-GBIC or New GBIC.
To use SFP GBIC ports, you will need the appropriate SFP GBIC modules. These modules are not delivered with the appliance but available through your Sophos partner. There are different module types. The required type is determined by the existing network. The following SFP GBIC module types may be used:
SG 210/230/310/330 8
Operating Instructions
SFP:
1000 Base-T
IEEE 802.3 - 1 Gbit/s via Ethernet cable. An Ethernet cable category 5 covers a maximum distance about 100 meters.
1000 Base-SX
IEEE 802.3 - 1 Gbit/s via fiberglass. Multi-mode fiberglass cables (MMF) cover a distance of 200 m to 550 m.
1000 Base-LX
IEEE 802.3 - 1 Gbit/s via fiberglass. Here, exclusively singlemode-fiber glass is used.
This transmission option covers approximately 10 km.
SFP+:
10GBase-SR
IEEE 802.3 - 10 Gbit/s via fiberglass. Multi-mode fiberglas cables cover a distance of up to 400 m.
10GBase-LR
IEEE 802.3 - 10 Gbit/s via fiberglass. Single-mode fiberglas cover a distance of approximately 10 km
Note: The SFP+ ports of the Sophos FleXi Port modules are dual-rate capable supporting both 1GbE and 10GbE speeds when using appropriate GBICs also supporting both rates.
Caution : The SFP GBIC and SFP+ ports use lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser equipment and are inherently eye-safe in normal operation. However, you should never look directly at a transmit port when it is powered on. Always install appropriate and UL approved Laser Class I Transceivers, rated 3.3Vdc, max. 1W, in the fiber ports before using the fiber ports.
Installing a SFP GBIC module:
Please read the operation manual to the SFP GBIC module. Carefully insert the SFP
GBIC module into the port until it engages. The interface is immediately ready for use.
Removing a SFP GBIC module:
1. Remove the fiberglass cable from the module which you wish to remove.
2. Remove the module carefully from the port.
Depending on when you purchased your SFP GBIC module, it may have any of three different release mechanisms: a plastic tab on the bottom of the mini-GBIC, a wire bail, or a plastic collar around the mini-GBIC.
Please read the operation manual to the SFP GBIC module.
SG 210/230/310/330 9
Operating Instructions
Serial Console
You can connect a serial console to the COM port of the Sophos UTM hardware appliances. You can use, for instance, the Hyperterminal terminal program which is included with most versions of Microsoft Windows to log on to the appliance console.
Use the provided RJ45 to DB9 adapter cable to connect the console to your hardware appliance.
The required connection settings are:
Bits per second: 38,400, Data bits: 8, Parity: N (none), Stop bits: 1. Access via the serial console is activated by default on ttyS1. The connections of the appliances and the respective functionality are listed in chapter “Operating Elements and
Connections.”
SG 210/230/310/330 10
Operating Instructions
United Kingdom and Worldwide Sales
Tel: +44 (0)8447 671131
Email: [email protected]
North American Sales
Toll Free: 1-866-866-2802
Email: [email protected]
Oxford, UK | Boston, USA
© Copyright 2014. Sophos Ltd. All rights reserved.
Registered in England and Wales No. 2096520, The Pentagon, Abingdon Science Park, Abingdon, OX14 3YP, UK
Sophos is the registered trademark of Sophos Ltd. All other product and company names mentioned are trademarks or registered trademarks of their respective owners.
1136-03.14DD.oina.simple
Australia and New Zealand Sales
Tel: +61 2 9409 9100
Email: [email protected]
Asia Sales
Tel: +65 62244168
Email: [email protected]
Stáhnout
Reklama