advertisement
Professional Headend Solutions
Operating instructions
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
Contents
1. Safety and operating instructions ................................................................... 2
2. Device variants ............................................................................................. 2
3. General ........................................................................................................ 2
4. Front view ..................................................................................................... 3
5. Functional description ................................................................................. 3
6. Adjustments ................................................................................................. 3
6.1 Adjustment with the Headend Controller ................................................ 3
6.2 Adjustment with the PC/ laptop ............................................................... 3
6.3 Adjustment with SNMP ............................................................................ 4
7. Meaning of the LED‘s .................................................................................... 4
7.1 LED‘s at the FM input ports ..................................................................... 4
7.2 Status LED‘s ............................................................................................ 4
8. Programming by web server (via HCB x00) ................................................. 5
8.1 Main menu ............................................................................................... 5
8.2 Extended settings .................................................................................... 6
8.3 Factory settings ....................................................................................... 6
8.4 Configuration of static RDS ..................................................................... 6
8.5 Status of the device ................................................................................. 7
8.6 Software overview ................................................................................... 7
9. Manual menu control at the Headend Controller ........................................ 8
10. Trap messages ............................................................................................. 8
11. Block diagram .............................................................................................. 9
12. Head end bus structure ............................................................................., 10
13. Application example ....................................................................................... 10
14. Technical data ............................................................................................. 11
15. Bibliography ................................................................................................ 11
16. Glossary ...................................................................................................... 12
17. Document history ........................................................................................ 12
Declaration of Conformity ........................................................................... 13
MCR 221
Part N
o
: 9054.01
MCR 221
Part N o
: 9054.01
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
1. Safety and operating instructions
B
LINE
When assembling, starting-up and adjusting the modules, it is necessary to consider the system specific references in the manual instruction.
The modules may only be installed and started up by authorized technical personnel.
When assembling the modules into the receiving points, the adherence of the EMC regulations is to be secured.
The assembly and wiring have to be done without voltage.
All active modules may only be operated with the Headend Controller HCB x00 or Bus Extender BEB x00.
The main voltage and the operating voltage of the modules working by DC have to be in complience to the operating parameters described in the technical data.
With all work the regulations of the DIN EN 50083 have to be considered. Especially the safety relevant execution of the
DIN EN 60728-11 [3] is necessary.
WEEE-Reg.-N o DE 50389067
2. Device variants
MCR 221 9054.01 2x FM [87,5 ... 108 MHz] → 2x FM [87,5 ... 108 MHz], S/PDIF (IN/ OUT)
Minimum software requirements for Headend Controller HCB x00:
9650.03:
9650.04/.05:
9652.01:
9653.01:
9653.02: version 2.34 version 3.18 version 3.23 version 3.27 version 3.28
1
1
1
1
1
1 Updates: www.blankom.de
3. General
The FM Modulator-Converter MCR 221 is a module of the head end system B-LINE, which is conceived as a complete system for middle sized networks. The module converts terrestrial FM radio channels into the FM cable frequency range.
All the components are programmed via a central control unit and will function independently thereafter. The status of the modules are displayed via LED’s (see chapter 7.2 “Status LED‘s“).
2
MCR 221
Part N o
: 9054.01
4. Front view
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
B
LINE
FM MODULATOR-CONVERTER
2x FM 2x FM, SPDIF (IN/OUT)
Type: MCR 221 Part No.: 9054.01
FM IN
INPUT LEVEL
FM OUT
OUTPUT LEVEL
87.5...108
63...100
87.5...108
SUPPLY CURRENT 0.75
MHz dBµV
MHz max. 2 x 110 dBµV
A
B
LINE managed by
SNMP
DCS
FM
IN
FM
IN/OUT
FM input 1
LED input 1
FM input 2/ output
LED input 2/ output
RDS input/ output
RDS
FM MODULATOR-CONVERTER
2x FM => 2x FM, SPDIF (IN/OUT)
Type:
MCR 221
Part No.:
9054.01
FM IN
INPUT LEVEL
FM OUT
OUTPUT LEVEL
SUPPLY CURRENT
87.5...108 MHz
63...100 dBµV
87.5...108 MHz max. 2 x 110 dBµV
0.75
A
FM
IN
OUTPUT
LOOP
OUT
X1
SPDIF 1
X2
STANDBY
READY 1
READY 2
ADDR.
SPDIF 2
Operating voltage/ control bus
S/PDIF input/ output 1,2
LED ”STANDBY” (red)
LED ”READY1” (green)
LED ”READY2” (green)
LED ”ADDR.” (yellow)
Address selector
Output coupler ”input”
Output coupler ”output”
gile
5. Functional description
The MCR 221 includes two low-noise receivers with large signal immunity for terrestrial FM signals with a frequency range from
87.5 MHz to 108 MHz and an output modulator for two FM channels in the same frequency range. The functions of the module are: amplification, selection, shift in the frequency range and level adjustments alignment of two of one or two receive antennas delivered terrestrial FM signals to prepare them for feeding into two FM cable channels. The input signals are demodulated and additionally they can be taken out the two RCA jacks as S/PDIF signal. The MCR 221 uses the Sub-D socket to output the received RDS data.
Furthermore, the MCR 221 can be used as a double FM modulator with S/PDIF inputs. The RDS data are added either statically via the HCB x00 or dynamically via the Sub-D socket.
The signal processing is based on the principle of double-superhet to avoid image frequency interferences. After a highly-selective range filtering and a input fader the input signal goes to an extremely low noise, while high sound performance PHEMT amplifier.
The following PHEMT mixer guarantees excellent intermodulation behavior in the first IF range. The first oscillator is constructed in fractional-N synthesizer technology, and thus guarantees a low phase noise. After selection and amplification, the signal passes to the second mixer, in which the standard IF of 10.7 MHz is generated. A quartz generator is used for both channels together as the oscillator. The further signal processing (selection, demodulation, stereo decoding and RDS separation) of the two IF signals is done digitally using a DSP. Separated from the DSP RDS and audio data streams are transported to the modulator FPGA. In the FPGA 2 full digital FM modulators are implemented. Here the audio signals are subjected of a 19-kHz filtering. It‘s be done the stereo processing: addition or subtraction of the audio signals and their modulation on the 38-kHz carrier. A 19-kHz pilot tone and RDS data are added to the audio signal. Then, the thus generated MPX signal is FM-modulated. The FM signals are combined, subjected to a D/ A conversion and are available via a directional coupler or directly at the output of the module. Each FM channel is individually generated and independently configurable.
Radio text plus (+ RT) is passed by the board of the receiving source to the receiver.
6. Adjustments
6.1 Adjustment with the Headend Controller
· Adjustment of the addresses at the Bus Extender BEB x00 and at the modules
· Activation of the programming mode on each module by selecting the line (BEB x00) and the module position (01... 15) at
the Headend Controller (HCB x00)
→ yellow LED illuminates until the beginning of the parameter adjustment
· Adjustment of the MCR 221 parameters (see chapter 9) → green LED is switched on
· After the programming the MCR 221 will be automatically switched into the operating mode
→ yellow LED flashes shortly/ green LED is switched on
The manual instructions of the Headend Controller HCB x00 and the Bus Extender BEB x00 have to be considered.
3
MCR 221
Part N o
: 9054.01
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
6.2 Adjustment with the PC/ laptop
B
· Remote programming requires an “online connection” according the IP standard and an ethernet connection at the PC/ laptop
· Adjustment of the line/ position addresses at the Bus Extender BEB x00 as well as at the modules
· At the Headend Controller HCB x00 input IP address (default: 192.168.2.80)
· For “direct connection” between a PC and HCB x00 use crossover cable (RJ 45)
· For connection over a hub use a normal straight throught patch cable
· Start-up HTML browser and put in IP address as target address
· If connected correctly the web interface will be opened on the pc and a blue LED (LINK) at the HCB x00 will be lit up.
· All adjustments of the modules are specified on the web interface.
LINE
6.3 Adjustment with SNMP
· The SNMP functionality requires the use of HCB x00 with enabled SNMP software option CKB 100.
· SNMP version 1.0 [4] is supported.
· Automatic creation of the MIB based on the current head end configuration by the HCB x00.
· For setting and reading out the parameters and to receive traps from an SNMP management additional software is required.
· Further notes on the SNMP functionality of BLANKOM modules are listed in the SNMP manual.
7. Meaning of the LED‘s
7.1 LED’s at the FM input ports
Colour
green yellow
Status
permanently on permanently on
Meaning of display
FM port is configured as input.
FM port is configured as output.
7.2 Status LED’s
Designation (Colour) Status
STANDBY (red) permanently on
READY 1 (green) flashing permanently on flashing
READY 2 (green) permanently on flashing
ADDR (yellow) illuminated/ flashing
Meaning of display
module is in standby module faulty (hardware error)
FM modulator 1 working properly, input signal is synchronized error warnings, depending on signal:
FM modulator 1 not synchronized on input (e.g. there is no input signal)
FM modulator 2 working properly, input signal is synchronized error warnings, depending on signal:
FM modulator 2 not synchronized on input (e.g. there is no input signal) remote control connection/ data being exchanged
4
MCR 221
Part N o
: 9054.01
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
8. Programming by web server (via HCB x00)
1
8.1 Main menu
Name of device, item number, address in head end
B
LINE
Channel
Description displays parameters for channel 1 or 2 channel name, editable (max. 30 characters)
Tuner settings
RF input
2 channel 1: input 1 (fixed) channel 2 selection: input 1, input 2
3
Input frequency adjustment range: 87500 ... 108000 kHz
Input attenuation selection: Auto
4
, 0 ... 31 dB
FM-Modulator
Signal source
Status input signal source, selection: Tuner, S/PDIF this displays whether there is SYNChronisa- tion or noSYNChronisation at the input of the modulator
RF-Output
RF-Signal selection: On, Off
Output frequency adjustment range: 87500 ... 108000 kHz
RF-Level correction adjustment range: +3 …-3 dB in 0.5-dB steps
(per channel)
Output attenuation adjustment range: 0 … 31 dB in 1-dB steps
(module)
RF-Output mode selection: Loop through, Only output
Audio settings
Audio mode
Audio gain selection: Mono, Mono1, Mono2, Stereo adjustment range: +6 ... -10 dB in 0.5-dB steps
RDS-Encoder
Operating mode selection: Off, Dynamic (Tuner), Dynamic
(External), Static
RDS-Data output selection: Enable, Disable
Routing to the adjustment menu: configuration static RDS (see menu 3)
Operating status selection: On, Off, reset
SNMP-Trap mess. selection: On, Off; if SNMP option in HCB x00
Factory settings enabled, otherwise “locked“ displays setting the default values (see menu 2)
Routing to the respective adjustment menus:
Extended settings see menu 1
Status see menu 4
Software versions see menu 5
2
input 1 and 2 about 11 dB input attenuation (directional coupler)
3
When input 1 assigned as the source of the channel 2, the FM port 2 is
configured automatically as output..
4
S/N max. 58 dB CCIR weighted
1
For further details see the HCB manual
5
MCR 221
Part N o
: 9054.01
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
8.2 Extended settings (menu 1)
Name of device, item number, address in head end
B
LINE
Channel
displays the adjustments of channel 1 or 2
Frequency settings
Frequency step
range input of the raster for setting the input and output frequency, range: 1 ... 500 kHz
Demodulator settings
Deemphasis selection: 50 µs, 75 µs, Off
Soft mute control
Mode selection: manual, automatic
Soft mute values (manually mode)
Start level input in dBµV
Attenuation input in dB
Modulator settings
Preemphasis selection: 50 µs, 75 µs, Off
Pilot signal selection: On, Off
Pilot deviation corr. adjustment range: +2 ... -2 kHz in
RDS-Signal
0.1-kHz-steps selection: On, Off
RDS-Deviation corr. adjustment range: +2 ... -2 kHz in
0.1-kHz-steps
8.3 Factory settings (menu 2)
When this menu item is requested, at first a security query whether it really set all parameters to the factory default settings pops up.
Affirming the query, all settings stored in the EEPROM will be deleted and replaced by the default settings (see chapter 9).
The module will go back to these default values.
Once the setting process is over, there will be an automatic return to the main menu. It takes about one minute.
8.4 Configuration of static RDS (menu 3)
6
Name of device, item number, address in head end
Configuration static RDS
Channel
displays the settings for the FM output channel 1 and 2
Output frequency displays the frequencies set for the FM channel
(in kHz)
PI-Code
PS-Name adjustment range: 0000 … FFFF (hex.)
1
8 characters of the name of the transmitted
Radio text
PTY-Code
EON program or service max. 64 characters, which can be transmit- ted statically selection of the program type selection: On, Off
M/S-Code
DI-Code
TP-Signal
TA-Signal
CT-Signal selection: music, language
Decoder-Identifikations-Control code, ente- red decimally, default setting: 1 (stereo) selection: On, Off selection: On, Off selection: On, Off
1 The current list of PI codes for German radio broadcasters can be found
on the following website: www.irt.de./de/themengebiete/
digitaler-hoerfunk/radio-daten-system-rds.html
MCR 221
Part N o
: 9054.01
8.5 Device status (menu 4)
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
B
LINE
Name of device, item number, address in head end
Channel
Tuner
Input frequency
Status
Input level
Attenuator
Stereo/ Mono displays status information of both channels displays in kHz status of synchronization of the demodula- tor displays in dBµV displays in dB audio mode of the receiving signal
SPDIF
Status
Information
Error memory
Temperature
Device number
Device index
S/PDIF status display: status of synchroni- zation, if used as an input or displays, if it used as an output
dynamically RDS data
Output frequency displays in kHz
PI-Code
PS-Name displays the sender‘s PI code displays the service name
Radio text
UTC-Time displays the radio text displays the UTC time putted out by RDS
Local time offset displays the offset betwen local and UTC time displays the errors arising in internal com- munication between the controllers displays the temperature of the device displays the device number displays the device index
8.6 Software overview (menu 5)
Name of device, item number, address in head end
Software versions
displays the software versions for the controllers as follows:
Controller of the front circuit board
Boot controller of the FM modulator FPGA
FM modulator FPGA
RDS encoder
Demodulator
7
MCR 221
Part N o
: 9054.01
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
9. Manual menu control at the Headend Controller (HCB x00)
B
LINE
The values in the blocks setting are the default values. After pushing the button “default“ settings on the main page, all settings stored in the EEPROM are erased and reset to default values. The device is set to these values again (see also chapter 8.3).
MCR 221 start
Edit or terminate
Module settings
Power status
Tuner input 2
On
Input 1
RF input
RF operation mode only output
Attenuation 10 dB
Deemphasis 50 µs
Channel 1...2 or end
Program settings
Channel name
Input frequency
Input attenuation
Source modulator max. 25 characters
87600 kHz
Auto
Tuner
RF output
Output frequency
RF level correction
FM output
Off
87600 kHz
0 dB
Audio settings
Audio mode
Audio amplification
stereo
0 dB
RDS settings
RDS mode/ source
RDS PI Code
RDS PS Name
RDS PTY Code
RDS TP Signal
RDS TA Signal
RDS M/S Signal
RDS DI Code
RDS EON
RDS CT Signal static
0x0000
(8 characters)
(selection)
Off
Off music
1
Off
Off
Settings preemphasis/ modulation
Preemphasis
Pilot signal
Pilot deviation correction
RDS signal
RDS deviation correction
50 µs
On
0 kHz
On
0 kHz
MCR 221 end
10. Trap messages
04
05
06
Item
01
02
03
Message
Signal OK
Input not sync
System reset
Power fail
ATMEGA: Open Error
NIOS: Open Error
Type
INFORMATION
WARNING
WARNING
CRITICAL
CRITICAL
CRITICAL
Explanation
Module works correctly
Input is not synchronized
Reset after internal error
Error on supply voltage
Access error FM boot controller
Access error RDS encoder
8
MCR 221
Part N o
: 9054.01
11. Block diagram
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
FM Frontend
G
B
LINE
FM IN
FM IN/ OUT
Supply
Control
Control
IF 1 IF 2
A
Processing
A
D D
DSP
2x FM Demodulator
2x FM
Modulator
FPGA
RDS
Controller
G
S/PDIF 1
S/PDIF 2
RF
D
A
RF IN
RF OUT
9
MCR 221
Part N o
: 9054.01
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
12. Head end bus structure
B
LINE
HCB x00
Headend
Controller
BEB x00
Bus Extender
Modul
signal processing unit
The number of the possible module connections (00 ... 15) to a
BEB x00 depends on the total power consumption of this line.
13. Application example
Integration in existing B-LINE configuration
Conversion of 10 FM programs into the cable network
Input antenna 1
Input antenna: 2 3 4
Output to existing combining
10x FM
Level opt. 92 dBµV
A B A B A B A B A B
HCB 200 MCR 221 MCR 221 MCR 221 MCR 221 MCR 221 PCB 190
10
MCR 221
Part N o
: 9054.01
14. Technical data
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
B
LINE
FM demodulator/ FM input
Input frequency range
Setting range for tuning interval
Level range (for signal noise ratio
≥ 58 dB)
Muting threshold
Return loss
Mono/ stereo threshold
Impedance
Connector
Directional coupler through loss
Time delay at co-channel operation
(f i
= f o
)
87.5 ... 108.0 MHz
1 ... 500 kHz
63 ... 100 dBµV
≤ 19 dBµV
1
≥ 14 dB
≤ 30 dBµV
1
75 Ω
F socket
< 2 dB
≤ 5 ms
1
FM modulator/ FM output
LF input
Max. FM deviation
2x S/PDIF according
EN 60958 [1]
75 kHz
LF level range (deviation correction) -10…+6 dB
Frequency range
Setting range for tuning interval
87.5…108 MHz
1 ... 500 kHz
Output impedance
Output return loss
between 18.9…19.1 kHz
and 23…100 kHz
75 Ω
> 16 dB
Amplitude response 40 Hz...15 kHz,
reference 400 Hz, preemph. 50 µs < ± 0.5 dB
Rejection of modulation frequencies
> 40 dB
Total harmonic distortion between
40 Hz…15 kHz at 40 kHz deviation > 66 dB at 400 Hz
40 Hz…15 kHz at 75 kHz deviation > 60 dB at 400 Hz
Difference-tone-attenuation D2 betw.
40 Hz…15 kHz > 70 dB
SNR weighted
(pre- and deemphase 50 µs, R, L) > 66 dB (Quasi-Peak-
Detector, CCIR weighted)
SNR unweighted
(pre- and deemphase 50 µs, R, L) > 72 dB (Quasi-Peak-
Detector, CCIR unweighted)
Cross-talk attenuation in range
40 Hz…100 Hz
100 Hz…15 kHz
Output frequency drift after
24 hours at 25 °C
> 38 dB (- 26 dBFS)
> 40 dB (- 26 dBFS)
< ± 2 kHz
Temperature depended
frequency drift
Spurios between
< ± 2 kHz
47…87.5 MHz and 111…862 MHz ≥ 64 dB
87.5…111 MHz
Nominal frequency error
≥ 60 dB
≤ 3 kHz
Output level (switchable)
direct output (w/o direct. coupler) max. 2x 110 dBµV
with directional coupler max. 2x 100 dBµV
Total level step
Individual level step
Connector
1 dB (0…31 dB)
0.5 dB (± 3 dB)
F socket
Stereo coder
Processing
Pilot deviation
Multiplex, CCIR
6.7 kHz
RDS coder
Processing
Deviation
Supported services
EN 62106:2001 [2]
2.4 kHz
PS, PTY, TP, TA, EON,
PI, RT, MS, CT, DI
In-/ output accord. UECP V 6.02 [5] D-SUB 9-pole
Operating parameters
Current/ voltage
Residual ripple of
supply voltage
12 V (± 0.2 V)/ 750 mA
≤ 10 mV pp
Enviromental conditions
Temperature range
Temperature range
for data keeping
Relative humidity
Method of mounting
Location of mounting
Miscellaneous
Dimensions (l x w x h)
without 19” adapter
with 19” adapter
Weight
Delivery content
1x Bus connector
2x F connecting cable 140 mm
-10 ... +55 °C
5 ... 45 °C
≤ 80 % (non condensing) vertical splash-proof and drip-proof
50 x 276 x 148 mm
50 x 301 x 148 mm
1,200 g
1
FM IN/ OUT used as FM input 2
15. Bibliography
[1] EN 60958-1: Digital audio interface - Part 1: General (IEC 60958-1:2008); German version EN 60958-1:2008
-3: Digital audio interface - Part 3: Consumer applications (IEC 60958-3:2006 + A1:2009); German version
EN 60958-3:2006 + A1:2010
-4: Digital audio interface - Part 4: Professional applications (IEC 60958-4:2003 + A1:2008); German version
EN 60958-4:2003 + A1:2008
[2] EN 62106:2001 : Specification of the radio data system (RDS) for VHF/ FM sound broadcasting in the frequency range from
87.5 to 108.0 MHz (IEC 62106:2000); German version
[3] EN 60728-11: Cable network for television signals, sound signals and interactive services Part 11: safety (IEC 607278-11: 2005).
German version EN 60728-11: 2005
[4] RFC 1157 Request for Comments (RFC): RFC Database; url: http://www.rfc-editor.org/rfc.html
[5] SPB 490: UECP-DS Universal Encoder Communication Protocol, Final version 6.02, September 2006-Copyright RDS Forum,
Geneva (Switzerland)
[6] EN 50083-2: Cable networks for television signals, sound signals and interactive services Part 2: Electromagnetic compatibility
for equipment, German version EN 50083-2:2006
11
MCR 221
Part N o
: 9054.01
FM Modulator-Converter
2x FM
→ 2x FM, S/PDIF (IN/ OUT)
16. Glossary
17. Document history
HTTP
ID
IF
IIC
IP
LED
MC
MIB
MPEG
MS
NIM
PCR
PI
PID
PLL
PMT
PS
PTY
RDS
RF
RT
SNMP
S/PDIF
SPI
SPTS
TA
TP
TS
UTC
AM
AP
ASI
ATV
AV
CCIR
CT
C/N
D/A
DI
DIN
DSP
DVB
EN
EON
ETSI
FIFO
FM
FPGA
Amplitude modulation
Anschlussplatte (front circuit board)
Asynchronus Serial Interface
Analog Television
Audio/ Video
Comité Consultatif International Radiocommunication
Clock Time
Carrier to Noise ratio
Digital/ Analog
Decoder-Identification-Control code
Deutsches Institut für Normung (German standards institute)
Digital signal processor
Digital Video Broadcasting (-C Cable, -S Satellite, -S2 Satellite 2, -T Terrestial)
Europäische Norm (European standard)
Enhanced Other Network
European Telecommunications Standards Institute
First In–First Out
Frequency modulation
Field Programmable Gate Array
Hypertext Transfer Protocol
Identifier
Intermediate Frequency
Inter-Integrated Circuit (I²C bus, data bus within module)
Internet Protocol
Light Emitting Diode
Microcontroller
Management Information Base
Moving Picture Experts Group
Music/ Speech
Network Interface Module
Program Clock Reference
Program Identification
Program Identifier
Phase Locked Loop
Program Map Table
Program Service Name
Program Type
Radio Data System
Radio Frequency
Radio Text
Single Network Management Protocol
Sony/Philips Digital Interface
Serial Peripheral Interface
Single Program Transport Stream
Traffic Announcement
Traffic Program
Transport Stream
Universal Time Coordinated
Version Date
1.00
06.09.2011
1.01
04.03.2014
Modification
basic document revision (extended settings, technical data)
Options available upon request. Subjects to changes due to technical progress.
Author
Häußer
Häußer
B
LINE
BLANKOM Antennentechnik GmbH
Hermann-Petersilge-Straße 1 • 07422 Bad Blankenburg • Germany • Phone +49 (0) 3 67 41 / 60-0 • Fax +49 (0) 3 67 41 / 60-100
12
Declaration of Conformity
Manufacturer: BLANKOM Antennentechnik GmbH
Hermann – Petersilge – Straße 1
07422 Bad Blankenburg
Germany
Product Name: FM Modulator-Converter
Type Name: MCR 221
Type N
o
: 9054.01
BLANKOM Antennentechnik GmbH confirms that the mentioned product meets the guideline(s) of the
Council for the approximation of legislation of the member states.
Electromagnetic compatibility (2004/ 108/ EC)
The following standards are met: DIN EN 50083-2: 2007-04 (EN 50083-2:2006-06)
Low voltage guideline (2006/ 95/ EC)
The following standards are met: DIN EN 60950-1: 2006-04 (EN 60950-1:2006-11)
Information technology equipment -Safety-
Restriction of hazardous substances (2011/ 65/ EC)
The following standards are met: DIN EN 50581: 2013-02 (EN 50581:2012)
Bad Blankenburg, Germany, 2011-11-23
Dr. Piero Kirchner
(Managing Director)
13
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 1. Safety and operating instructions
- 2 2. Device variants
- 2 3. General
- 3 4. Front view
- 3 5. Functional description
- 3 6. Adjustments
- 3 6.1 Adjustment with the Headend Controller
- 3 6.2 Adjustment with the PC/ laptop
- 4 6.3 Adjustment with SNMP
- 4 7. Meaning of the LED‘s
- 4 7.1 LED‘s at the FM input ports
- 4 7.2 Status LED‘s
- 5 8. Programming by web server (via HCB x00)
- 5 8.1 Main menu
- 6 8.2 Extended settings
- 6 8.3 Factory settings
- 6 8.4 Configuration of static RDS
- 7 8.5 Status of the device
- 7 8.6 Software overview
- 8 9. Manual menu control at the Headend Controller
- 8 10. Trap messages
- 9 11. Block diagram
- 10 12. Head end bus structure
- 10 13. Application example
- 11 14. Technical data
- 11 15. Bibliography
- 12 16. Glossary
- 12 17. Document history
- 13 Declaration of Conformity