- Industrial & lab equipment
- Electrical equipment & supplies
- Power conditioning
- Electrical relays
- User manual
advertisement
▼
Scroll to page 2
of 19
VFD 400 Installation Manual FULL DIGITAL SERVODRIVE FOR BRUSHLESS SERVOMOTORS VFD400F SERIES INSTALLATION MANUAL DOCUMENT NUMBER: EDITION: AUTHOR: DATE: MNINVFD4_0F-UK02 02 A. Montanaro, A. Kanev July 2004 The material in this manual is for informational purposes only and is subject to change without notice. All rights reserved. This document shall not be reproduced, either entirely or in part, without written authorization. MNINVFD4_0F-UK02 1 VFD 400 Installation Manual Edition 01 02 Date 04/2004 07/2004 MNINVFD4_0F-UK02 Remarks Preliminary Edition Last Edition 2 VFD 400 Installation Manual CONTENTS 1. External connections........................................................................................................................................... 4 1.1. Power connector - X1 ................................................................................................................................. 7 1.2. Auxiliary supply connector - X2................................................................................................................. 9 1.3. Brake connector - X3 (Option) ................................................................................................................... 9 1.4. Control unit connector - X7 ...................................................................................................................... 10 1.5. Encoder emulation or encoder - linear scale input connector – X5 ....................................................... 11 1.6. Resolver connector – X6........................................................................................................................... 11 1.7. Fieldbus connector – X4 (CAN VERSION ONLY) ................................................................................. 12 1.8. Fieldbus connector – X4 (PROFIBUS VERSION ONLY) ...................................................................... 12 1.9. RS232 Cables............................................................................................................................................ 13 1.10. Table Of Conductor Cross-Sections ..................................................................................................... 14 2. Mechanical Installation .................................................................................................................................... 15 Appendix A – Single Fase Operation........................................................................................................................ 19 MNINVFD4_0F-UK02 3 VFD 400 Installation Manual 1. External connections X4 X4 X1 X5 X6 X2 X1 X5 X2 X6 X3 X3 X7 X7 CAUTION ! VFD400FC Front View MNINVFD4_0F-UK02 CAUTION ! VFD400FP Front View 4 VFD 400 Installation Manual Figure 1 MNINVFD4_0F-UK02 5 VFD 400 Installation Manual Figure 2 MNINVFD4_0F-UK02 6 VFD 400 Installation Manual 1.1. Power connector - X1 Connector X1 is dedicated to connections of power supply, motor and clamp resistor. Power connector X1 1.1.1. Pin 1 Ref. R Description Three phase power supply (max 230 VAC) 2 S Three phase power supply (max 230 VAC) 3 T Three phase power supply (max 230 VAC) 4 U Motor phase U 5 V Motor phase V 6 W Motor phase W 7 +VBUS 8 RCL 9 RCL EXT 10 -VBUS + DC bus Internal clamp resistor Internal/external clamp resistor - DC bus Table 1.1 Motor connection • Connect the motor cables to terminals 4, 5 and 6 observing the correct pole connection. • Connect the PE cable to one of the two PE screw terminals on the front panel. 1.1.2. Clamp resistor connection • When using the internal resistor connect terminals 8 and 9. • When using an external resistor, connect the resistor between terminals 7 and 9 (see fig. 1). 1.1.3. Mains connection • Connect terminals 1, 2 and 3 between three phases at 230 Vac line to line mains connection. • Insert the fuses specified in figure 1 in series with the cables. • Connect the PE cable to one of the two PE screw terminals on the front panel. The IT connection are adviced against because it's very hard verify the overcoming of the limits in transitory regimen. MNINVFD4_0F-UK02 7 VFD 400 Installation Manual TT at 400Vac IT at 400Vac MNINVFD4_0F-UK02 8 VFD 400 Installation Manual 1.2. Auxiliary supply connector - X2 Connetions for an external auxiliary power supply at 24 Vdc ± 15% – 1,5A max Auxiliary supply connector X2 1 Pin Ref. Description 1 L1C aux. Supply +24 Vdc ± 15% – 1,5 A max 2 L2C aux. Supply GND 24 Vdc 2 Table 1.2 1.3. Brake connector - X3 (Option) This option may be used with motors including an electromagnetic brake. Brake connector X3 Pin Ref. Description 1 24VOUT Internal brake supply (24V DC, 0.8A max) 2 24BRIN Brake supply input (24V DC, 2A max) 3 B+ Brake output + 4 B- Brake output – (GND 24 Vdc) Table1.3.1 • The drive automatically cuts off power and releases the electromechanic brake when connection between pins 1 and 2 is open. • Connect a potential free contact emergency switch between pins 1 and 2, or jumper them. • Brake supply input: connect between pin 2 (24 Vdc, 2 A) and pin 4 (GND 24 Vdc, 2 A). VFD400 F 03 VFD400 F 05 Resistence [Ω] 56 33 15 15 Nominal Power [W] 110 110 220 220 Tp(peak) [V] 400 400 400 400 Tp (o) [V] 1.8 1.8 SIR SRC + SB1G20 A+T 29x165 1.8 1,8 / IRE CBR 180 / 195x45x11,5 Resistors Model / Dimensions [mm] / VFD400 F 07 VFD400 F 10 Table1.3.2 MNINVFD4_0F-UK02 9 VFD 400 Installation Manual 1.4. Control unit connector - X7 • VREF+/VREF-: analog reference input (+/-10 V differential). It is used to control the motor speed when the converter is configured in Analog Speed Mode or the motor current when the converter is configured in Analog Current Mode. • ENABLE: digital input (15÷24V, 20 mA) to enable the power stage of the converter. • RESET: digital input (15÷24V, 20 mA) to reset fault. • FAULT1/FAULT2: relay contact normally closed when the converter is ready to switch-on or is running. The contact is open when the converter is not ready to switch-on or a fault condition has occurred. Control unit connector X7 Pin Ref. Description 1 VREF+ Speed (or current) reference input + 2 VREF- Speed (or current) reference input - 3 -15V-OUT Auxiliary voltage output (50mA max.) 4 +15V-OUT Auxiliary voltage output (50mA max.) 5 AGND 6 SHIELD Shield 7 RESET Fault reset 8 ENABLE 9 DIN1 Digital input 1 10 DIN2 Digital input 2 11 DIN3 Digital input 3 – Home switch 12 DIN4 Digital input 4 13 DIN5 Digital input 5 14 DIN6 Digital input 6 15 GNDCMD 16 +24V-IN 24V input 17 DOUT1 Digital output 1 18 DOUT2 Digital output 2 19 FAULT1 Drive ready signal output (relay contact) 20 FAULT2 Drive ready signal output (relay contact) Analog ground Power enable input 24V common signal Table1.4 MNINVFD4_0F-UK02 10 VFD 400 Installation Manual 1.5. Encoder emulation or encoder - linear scale input connector – X5 The signals on this connector are bidirectional. It is possible to configure the encoder as input, for external encoder, or as output, for motor feedback position. Encoder emulation connector X5 Pin Ref. Description 1 ENC-A- RS422 A – signal 2 ENC-A+ RS422 A + signal 3 ENC-B- RS422 B – signal 4 ENC-B+ RS422 B + signal 5 ENC-C- RS422 C – signal (zero marker) 6 ENC-C+ RS422 C + signal (zero marker) I motori con encoder sincos possono essere di diverso tipo. Il cablaggio mostrato è 7 con GND Ground(chiamate nella tabella tracce lente). In genere valido per encoder tracce assolute per le righe ottiche tracce non sono disponibili. In questo caso il motore potrebbe 8 queste SHIELD Shield essere dotato di sensori di Hall i quali devono essere collegati al connettore X4 (par. 9 AGND 10 +5V-ENC Analog ground +5V encoder supply (max 150 mA) Table 1.5 1.6. Resolver connector – X6 Resolver connector X6 Pin Ref. Description 1 THERM2 2 N.C. 3 + REFRES + resolver reference 4 + SINRES + resolver sinus signal 5 + COSRES + resolver cosinus signal 6 THERM1 Motor thermal protection (1) 7 - REFRES - resolver reference 8 - SINRES - resolver sinus signal 9 - COSRES - resolver cosinus signal Motor thermal protection (2) Not connected Table 1.6 MNINVFD4_0F-UK02 11 VFD 400 Installation Manual 1.7. Fieldbus connector – X4 (CAN VERSION ONLY) CAN connector X4 Pin Ref. Description 1 N.C. Not connected 2 CANL Can Bus Low 3 N.C. Not connected 4 RX232 5 N.C. Not connected 6 GND RS232 ground 7 CANH Can Bus High 8 TX232 RS232 TX signal 9 N.C. RS232 RX signal Not connected Table 1.7 1.8. Fieldbus connector – X4 (PROFIBUS VERSION ONLY) Profibus connector X4 Pin Ref. 1 SHIELD Shield 2 RX232 RS232 RX signal 3 RxD/TxD-P 4 N.C. 5 DGND 6 VP 7 TX232 8 9 Description Receive/Transmit Data – plus Not connected Data ground Supply voltage – plus (+5V iso) RS232 TX signal RxD/TxD-N Receive/Transmit Data – minus GND RS232 ground Table 1.8 MNINVFD4_0F-UK02 12 VFD 400 Installation Manual 1.9. RS232 Cables Used to connect a PC RS232 serial line. • RS232: - maximum cable length: 10 meters; - max capacitance: 2500 pF; - shielded cable. Fig. 1.9.1 – VFD400C (CAN) RS232 cable Fig. 1.9.2 – VFD400P (PROFIBUS) RS232 cable MNINVFD4_0F-UK02 13 VFD 400 Installation Manual 1.10. Table Of Conductor Cross-Sections Function Connectors VFD400Fx03 Clamp resistor cable X1 1.5 mm Motor cable X1 1.5 mm Power supply cable X1 1.5 mm VFD400Fx05 VFD400Fx07 VFD400Fx10 2 2 2.5 mm 2 2 2.5 mm 2 Brake cable, brake X2, X3 supply and services 0.5 ÷ 1 mm Resolver cable 0.14 ÷ 0.22 mm Control cable unit X6 signal X5, X7 2 2 2 0.14 mm Table 1.10 MNINVFD4_0F-UK02 14 VFD 400 Installation Manual 2. Mechanical Installation Use the brackets and the screws supplied with the converter for mounting VFD300. • fix the bottom bracket to the mounting panel with two screws; • place the converter on the bottom bracket; • place and fix with a screw the top bracket. k k2 k1 c = g e1 = = = = = LD X1 X4 b1 d X5 b d X6 X2 X3 X7 CAUTION ! = = M4 holes e m c c1 c2 Allow a free space for assembling the connecting cables c1 a Fig. A Type Fig. a b b1 c c1 c2 d e e1 g k k1 k2 m A 70 252 206 16.5 39.5 14 238 +1 -0 170 174 5.5 4.5 63.5 2 Ø5.5 VFD3CRA2003000C VFD3CRA2005000C B 80 252 206 24 39.5 16.5 238 +1 -0 190 194 5.5 12 63.5 4.5 Ø5.5 All dimensions in mm Fig. 2.1 – VFD400 FC 03 CAN version VFD400 FC 05 CAN version MNINVFD4_0F-UK02 15 VFD 400 Installation Manual k k2 k1 c = g e1 = = = = b3 LD X1 X4 d b1 b d X5 X6 X2 X3 X7 CAUTION ! b2 = M4 holes e m c c1 c2 Allow a free space for assembling the connecting cables c1 a Fig. C Type Fig. a b b1 b2 b3 c c1 c2 d e e1 g k k1 k2 m 190 194 5.5 12 63.5 4.5 Ø5.5 190 194 5.5 12 63.5 4.5 Ø5.5 VFD3CRA2007000C C 80 271 206 23 41.5 24 39.5 16.5 257 +1 -0 VFD3CRA2010000C C 80 271 206 23 41.5 24 39.5 16.5 257 +1 -0 All dimensions in mm Fig. 2.2 – VFD400 FC 07 CAN version VFD400 FC 10 CAN version MNINVFD4_0F-UK02 16 VFD 400 Installation Manual k k2 k1 c = g e1 = = = = = LD X1 X4 b1 d X5 b d X6 X2 X3 X7 CAUTION ! = = M4 holes e m c c1 c2 Allow a free space for assembling the connecting cables c1 a Fig. A Type Fig. VFD3CRA4003000C VFD3CRA4005000C A B a 70 80 b 252 252 b1 206 206 c 16.5 24 c1 39.5 39.5 c2 d e e1 g k k1 k2 m 14 238 +1 -0 170 174 5.5 4.5 63.5 2 Ø5.5 16.5 238 +1 -0 190 194 5.5 12 63.5 4.5 Ø5.5 All dimensions in mm Fig. 2.3 – VFD400 FP 03 PROFIBUS version VFD400 FP 05 PROFIBUS version MNINVFD4_0F-UK02 17 VFD 400 Installation Manual k k2 k1 c = g e1 = = = = b3 LD X1 X4 d b1 b d X5 X6 X2 X3 X7 CAUTION ! b2 = M4 holes e m c c1 c2 Allow a free space for assembling the connecting cables c1 a Fig. C Type Fig. a b b1 b2 b3 c c1 c2 d e e1 g k k1 k2 m 190 194 5.5 12 63.5 4.5 Ø5.5 190 194 5.5 12 63.5 4.5 Ø5.5 VFD3CRA4007000C C 80 271 206 23 41.5 24 39.5 16.5 257 +1 -0 VFD3CRA4010000C C 80 271 206 23 41.5 24 39.5 16.5 257 +1 -0 All dimensions in mm Fig. 2.4 – VFD400 FP 07 PROFIBUS version VFD400 FP 10 PROFIBUS version MNINVFD4_0F-UK02 18 VFD 400 Installation Manual Appendix A – Single Fase Operation µ O Figure A1 – Connection for VFD 400 F in single phase operation MNINVFD4_0F-UK02 19
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project