John Z.
What is the function of the System Cover Release Button?
The System Cover Release Button is used to unlock and open the system cover of the device.
Below you will find brief information for Panel PC YUNO 151, Panel PC YUNO 156. These panel PCs are designed for use in retail environments and feature a touchscreen interface, a variety of connectivity options, and a compact design. The YUNO 151 and YUNO 156 are equipped with an Intel® Bay Trial-M SoC Processor J1900 (2M Cache, up to 2.42 GHz) and 1 x SO-DIMM DDR3L 1067/1333MHz, Max 8GB of system memory. They also offer a range of peripherals, including a cash drawer and an attachment-type customer display.
Advertisement
Advertisement
YUNO-151& YUNO-156
© 2014All rights reserved. The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer.
This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of the manufacturer.
All trademarks are property of their respective owners
In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio or television technician for help.
NOTE: THE MANUFACTURER IS NOT
RESPONSIBLE FOR ANY RADIO OR TV
INTERFERENCE CAUSED BY UNAUTHORIZED
MODIFICATIONS TO THIS DEVICE. SUCH
MODIFICATIONS COULD VOID THE USER'S
AUTHORITY TO OPERATE THE DEVICE.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the Federal Communications Commission
(FCC) Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
This device complies with EMC Directive
2004/108/EC and 2006/95/EC “Low Voltage
Directive” issued by the Commission of the
European Community i
The WEEE mark applies only to countries within the
European Union (EU) and Norway.
This appliance is labeled in accordance with
European Directive 2002/96/EC concerning waste
electrical and electronic equipment (WEEE). The
Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union. This label is applied to various products to indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive.
IMPORTANT SAFETY INSTRUCTIONS
To disconnect the machine from the electrical Power
Supply, turn off the power switch and remove the power cable plug from the wall socket. The wall socket must be easily accessible and in close proximity to the machine.
Read these instructions carefully. Save these instructions for future reference.
Follow all warnings and instructions marked on the product.
Do not use this product near water.
Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product.
Slots and openings in the cabinet and the back or bottom are provided for ventilation; to ensure reliable operation of the product and to protect it from overheating. These openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register, or in a built-in installation unless proper ventilation is provided.
This product should be operated from the type of power indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
Do not allow anything to rest on the power cord. Do not locate this product where persons will walk on the cord.
Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product.
ii
4.2 Install the Attachment-type Customer Display (YUNO-VFD) ................................... 20
Appendix B: Customer Display Command Settings ....................................... 27
iii
b. Power Adapter (65W) a. System c. Power Cable e. Manual CD d. RJ50-COMCable 100cm (x2), plus,
RJ50-COMCable 50cm (x2)
1
YUNO supports full range of peripherals as listed below.
Model #
YUNO-VFD
YUNO-UPS
YUNO-WBM
Description
RS-232 interface
Attachment-type (integrated) Customer Display
Intelligent Uninterruptible Power Supply Module
Wi-Fi Bluetooth Module
2.4/5GHz, 802.11ac, a/b/g, n
2
Number
1
2
3
4
Description
Bezel Free Panel PC
L-Stand
System Cover Release Button
Base Plate
3
Number
5
6
7
8
9
10
Description
Attachment-type Customer Display (YUNO-VFD) service door
System Cover service door for peripherals
VESA mount (75mm x 75mm)
Rear Side Cable service door
L-Stand Cover
4
Number
11
12
13
Description
Power Button
1 x USB 2.0
1 x USB 3.0
5
6
7
Bottom-up View
Right-side View
Bottom-up View
Number a b c d e f g h
Right-side View
Number i j
Description
DC-IN jack
Combo Audio jack (3.5mm 4 conductor)
COM1~4 (from right to left) (RJ50 Connector)
LAN (RJ45 Connector)
4 x USB 2.0 (Type A)
Cash Drawer (RJ12 Connector) mini DP (Display Port) reserved for Wi-Fi /Bluetooth
8
Description
1 x USB 3.0 (Type A)
1 x USB 2.0 (Type A)
Open the System Cover by pressing the System Cover Release Button.
9
YUNO offers two 2.5" drive bays of height 7 mm each to allow you to equip it with a configuration of one primary HDD or SSD on the upper bay and one secondary SSD on the lower bay.
*Please note that if you are replacing your only HDD or SSD, you will need to reinstall your operating system after replacing it.
Make sure the unit is powered off before starting.
Please follow the below steps to finish the replacement :
1. Remove the System Cover
To open the System Cover, please refer to the procedures described in Chapter
3-1 and remove it.
2. Remove the old drive (if applicable).
If you are removing a HDD or SSD, make sure all of the cables are disconnected from both the motherboard and the power supply. Rotate the Releasing Handler to unlock the storage disk drive and slide it out of the housing.
3. Insert your new drive.
Remove it from the antistatic packaging and slide it into your target drive bay of the storage housing.
10
4. Secure the storage disk drive.
Once the storage disk drive has been completely inserted, rotate the Releasing
Handler to lock it properly.
5. Connect the storage disk drive to the motherboard.
*If you are connecting your primary storage disk drive, the SATA cable should be plugged into the first SATA channel, which is labeled as SATA0. Refer to Chapter 6 about the motherboard configuration for detailed information.
Secondary drive should be connected to the next available SATA1 channel.
11
6. Connect the power supply to the storage disk drive.
HDD1 labeled on the motherboard provides power supply to the primary storage disk drive, while HDD2 is for the secondary storage disk drive.
Make sure that all of your connections are secure.
7. Get ready to power on the system.
Close up the System Cover.
Reconnect the cable plug onto the wall socket and turn your YUNO on.
8. Finish the replacement.
If you are replacing your primary drive, you'll have to reinstall your operating system.
If you are adding a new drive, you'll need to format the drive before you can use it.
12
Make sure the system is powered off before starting.
Please follow the below steps to finish the replacement :
1. Remove the System Cover
To open the System Cover, please refer to the procedures described in Chapter
3-1 and remove it.
2. Locate the memory slot at the left rear side of the system.
3. Flip the ejector clips outwards to remove the memory module from the memory slot.
4. Slide the memory module into the memory slot and press down until the ejector clips snaps in place.
13
5. Close up the System Cover.
14
The system is equipped with a 65W power adapter. Please follow below procedures to get it plugged into the system.
1. To open the System Cover, please refer to the procedures described in Chapter 3-1, and remove it.
2. Locate the power connector on the I/O panel (please refer to Chapter 2-5) and connect the plug of power adapter directly to the DC-IN jack.
Route the DC cord connection securely.
3. Remove the L-Stand Cover to locate the rest of DC cord properly.
4. After finish, slide in the L-Stand Cover and close up the System Cover.
15
YUNO follows VESA Mounting Interface Standard to allow you to mount the elegant bezel-free panel PC to a stand or wall with four M4 screws easily.
The horizontal and vertical distance between the tapped holes on YUNO is 75 mm.
Make sure the system is powered off before starting.
Please follow the below steps to get it ready for the mounting process :
1. Remove the System Cover.
To open the System Cover, please refer to the procedures described in Chapter
3-1, and remove it.
2. Remove the L-Stand Cover.
3. Detach the panel PC by unscrewing the10 pcs of screws from the L-Stand Cover.
4. Remove the 4 pcs of rubber cap from the System Cover.
16
5. Get ready to the mounting process.
Close up the System Cover and then mount it to a stand or wall with four M4 screws easily.
17
You can install a cash drawer through the cash drawer port.
Please verify the pin assignment before installation.
Cash Drawer Pin Assignment
Pin
1
Signal
GND
2
3
4
5
6
DOUT bit0
DIN bit0
12V / 19V
DOUT bit1
GND
Cash Drawer Controller Register
The Cash Drawer Controller use one I/O addresses to control the Cash Drawer.
Register Location : 48Ch
Attribute : Read / Write
Size : 8-bit
BIT BIT7 BIT6 BIT5 BIT4
Attribute Reserved Read Reserved
BIT3 BIT2
Write
BIT1 BIT0
Reserved
7 6 5 4 3 2 1 0
X X X X X
Reserved
Cash Drawer “DOUT bit0” pin output control
Cash Drawer “DOUT bit1” pin output control
Reserved
Cash Drawer “DIN bit0” pin input status
Reserved
18
BIT7: Reserved
BIT6: Cash Drawer “DIN bit0” pin input status.
= 1: the Cash Drawer opened
= 0: the Cash Drawer closed or no Cash Drawer
BIT5: Reserved
BIT4: Reserved
BIT3: Cash Drawer “DOUT bit1” pin output control.
= 1: Opening the Cash Drawer
= 0: Allow close the Cash Drawer
BIT2: Cash Drawer “DOUT bit0” pin output control.
= 1: Opening the Cash Drawer
= 0: Allow close the Cash Drawer
BIT1: Reserved
BIT0: Reserved
Note: Please follow the Cash Drawer control signal design to control the Cash
Drawer.
Cash Drawer Control Command Example
Use Debug.EXE program under DOS or Windows98
Command Cash Drawer
O 48C 04 Opening
O 48C 00 Allow to close
Set the I/O address 48Ch bit2 =1 for opening Cash Drawer by “DOUTbit0” pin control.
Set the I/O address 48Ch bit2 = 0 for allow close Cash Drawer.
Command Cash Drawer
I 48C Check status
The I/O address 48Ch bit6 =1 mean the Cash Drawer is opened or not exist.
The I/O address 48Ch bit6 =0 mean the Cash Drawer is closed.
19
The Attachment-type Customer Display(YUNO-VFD) can be installed from the rear top side of the system. Make sure the unit is powered off before starting.
Please follow the below steps to finish the installation :
1. Unscrew the two pcs of screws from the rear top service door and remove it.
2. Connect the Customer Display cable with the connector of the system. Locate this connection properly.
3. Insert the Customer Display in place and fasten the two pcs of screws to make it secure.
20
Model Name
Model Number
CPU support
YUNO
YUNO-151 YUNO-156
Intel® Bay Trial-M SoC Processor J1900
(2M Cache, up to 2.42 GHz))
System memory
LAN controller
Audio controller
Audio
BIOS
1 x SO-DIMM DDR3L 1067/1333MHz, Max 8GB
RTL8111G PCI-E Gigabit LAN
Realtek ALC662 HD Audio CODEC with 2-Channel
2W Speaker x 2
Phoenix uEFI BIOS
LCD Panel
LCD size 15.0" (Innolux G150XGE-L05) 15.6" (Innolux N156BGE-L41)
Brightness
Maximal resolution
250 cd/m²
1024 x 768
200 cd/m²
1366 x 768
Aspect Ratio
Backlight Type
4:3
LED
Touch Sensor
P-CAP Touch QM (Shanghai) Technology,
Model: PIF15003
16:9
LED
QM (Shanghai) Technology,
Model: PIF15601
Touch Screen
Controller IC
Interface
10
3M Dori1
USB
10
SiS 9275
USB
Storage
1st HDD / SSD 1 x 2.5" 7mm
SATA HDD or SATA MLC SSD
2nd SSD 1 x 2.5" 7mm
SATA MLC SSD
Side I/O
Power button
USB
1 x with power indicator (blue color when power ON)
1 x USB 2.0 and 1 x USB 3.0
21
Rear Bottom I/O
DC-IN jack
Audio jack
Serial / COM
1 x radio jack connector for 19V DC input
1 x 4-conductor 3.5mm audio jack for MIC-in and Line-out
4 x RJ50 connector with RJ50 to DB9 cable for RS-232 port
- COM1/COM2: RS232, wake on ring (S1, S3, S4, S5) support
- COM3/COM4: RS232, powered COM with BIOS select none
(Default setting)/ +5V (Default) / +12V for DB9 pin9 by BIOS setting.
LAN
USB
Cash Drawer
Display Port
1 x RJ45 port for Gigabit Ethernet, support Wake on LAN
4 x USB 2.0
1 x RJ12, support 12V / 24V DC Cash Drawer
1 x mini Display Port
(supporting active converter cable to VGA, DVI, HDMI)
Power
Power Adapter
Peripherals
Customer Display
External 19V / 3.42A 65Watt Adapter
Attachment-type Customer Display (YUNO-VFD option)
(Serial COM6)
UPS Module
Communication
Wireless LAN
Intelligent UPS Module (YUNO-UPS option)
2.4/5GHz, 802.11ac, a/b/g, n
Wi-Fi Bluetooth Module (YUNO-WBM option)
Certifications
EMI
Safety
Environment
Operating temperature
FCC Class B / CE / LVD
UL
0℃ ~ 35℃ (32℉ ~ 95℉)
Storage temperature
Humidity
Dimension
(W x D x H)
LCD 90 degree :
-20℃ ~ 60℃ (-4℉ ~ 140℉)
5% ~ 80%, non-condensing
360.1 x 171.5 x 316.1 mm
LCD 90 degree :
402.2 x 171.5 x 295.3 mm
Weight (N.W./G.W.)
OS support
10kg / 11kg 11kg / 12kg
Windows® 7 Professional for Embedded Systems,
Windows® Embedded POSReady 7,
Windows® Embedded 8 Industry Retail
* This specification is subject to change without prior notice.
22
23
Internal
Connectors
LVDS1
LVDS2
HDD1
HDD2
INT_SP
DIMM1
CRT1
JP5
JP6
JP7
External
SW4
DC-IN
CN11
COM1,COM2,COM3,COM4
LAN_CON1
USB_CON1
USB_CON2
RJ12
MINI_DP1
USB30_1
USB20_3
Functions
50-pin connector
40-pin connector
SATA power connector
SATA power connector
Speaker connector
DDR3 SO-DIMM
VGA connector (internal)
LCD Enable Level Select
LCD Power Select
RJ12 Power Select
Power button
DC-IN jack
3.5mm 4 conductor Audio jack
(Combo MIC-in and Line-out )
RJ50 Serial Ports
LAN port
USB2.0 port0/1
USB2.0 port2/3
Cash Drawer mini DP (Display Port)
USB3.0 port0/1
USB2.0 port4/5
24
LCD Enable Level Select
Function
+5V
+3.3V (Default)
LCD Power Select
Function
+5V
+3.3V (Default)
RJ12 Cash drawer Power Select
Function
+19V (Default)
+12V
■■
SHORT
■■
OPEN
JP5
(1-2)(2-3)
1 2 3
1 2 3
JP6
(1-2)(2-3)
1 2 3
1 2 3
JP7
(1-2)(2-3)
1 2 3
1 2 3
25
To download the most recent drivers and utilities, and obtain advice regarding the installation of your equipment, please visit the AURES Technical Support Website: www.aures-support.fr(French) www.aures-support.fr/UK(English) www.aures-support.fr/GE(German)
26
(1) Data can be displayed on 20 columns x 2 lines.
(2) Blue-green color and large characters are easy to eye.
(3) The commands modes, fonts, baud rate and other parameters are selected by software.
(4) CD5220 / UTC / EMAX / ADM / EscPOS / DSP-800 emulation command sets.
(5) User-defined characters can be downloaded
(for EscPOS /CD5220/DSP-800 command).
(6) Provides an interface based on RS-232C or USB
(baud rate: 4800, 9600, 19200, 38400, 115200 bps).
(7) Powered by 5V.
27
No Item
1 Display method
Description
Vacuum fluorescent display
2 Number of character
3 Character font
4 Display color
5 Brightness
6 Character type
7 Character size
8 Power supply
9 Power consumption
10 MTBF
11 Module dimensions
12 Weight
13 Operating temperature
14 Operating Humidity
15 Storage Temperature
40 characters ( 20 columns x 2 lines)
5 x 7 dot matrix
Blue green
~ 500 cd/m²
96 alphanumeric
13 kinds of international character set
1 kind of user define character
9.03 mm x 5.25 mm
5 V
2.3W (Max.)
25,000 hours
146 (W) x 49.2 (H) x 15.2 (D) mm
85g
0 ~ 45℃
30% ~ 85%
-10 ~ 50℃
16 Storage Humidity 10% ~ 90%
28
Data transmission
Synchronization
Handshaking
Signal level
Baud rates
Parity and bit length
Stop bits
Serial
Asynchronous
DTR / DSR
MARK = -3 to –15 V (logic “1”)
SPACE = +3 to +15 V (logic “0”)
4800,9600,19200,38400 or 115200 bps
None parity, 8 data bits or
Even parity, 7 data bits
1 or more
29
CN6
CN2
Connector type: JST/ZH/1.5mm/6P
Pin assignment
No Signal Direction
1 TXD From display to PC/Host
2 RXD From PC/Host to display
3 RTS From display to PC/Host
4 CTS From PC/Host to display
1 6
Function Description
5 GND
6 Vin
-
-
Signal ground
Power 5 Vdc
1 4
Connector type: JST/ZH/1.5mm/4P
Pin assignment
No Signal
1 GND
2 USBD+
Direction
-
-
Function Description
Signal ground
USB data signal +
3 USBD-
4 5Vdc
-
5V From PC/Host
USB data signal -
Power 5 Vdc
Type: JST/XH/2.5mm/2P
Location
J1
J2
SHORT
RS232 enable
USB enable
OPEN
RS232 disable
USB disable
30
Command
ESC DC1
ESC DC2
ESC DC3
ESC QA ....CR
ESC QB ....CR
ESC QD ....CR
ESC [ D
BS
ESC [ C
HT
ESC [ A
ESC [ B
LF
ESC [ H
HOM
ESC [ L
CR
ESC [ R
ESC [ K
ESC l x y
1B 11
1B 12
1B 13
Code (hex)
1B 51 41 data x m 0D
1B 51 42 data x m 0D
1B 51 44 data x m 0D
1B 5B 44
08
1B 5B 43
09
1B 5B 41
1B 5B 42
0A
1B 5B 48
0B
1B 5B 4C
0D
1B 5B 52
1B 5B 4B
1B 6C x y
Function Description
Overwrite mode
Vertical scroll mode
Horizontal scroll mode
Set the string display mode,write string to upper line m ≦ 20
Set the string display mode, write string to lower line m ≦ 20
Upper line message scroll continuously m ≦ 40
Move cursor left
Move cursor left
Move cursor right
Move cursor right
Move cursor up
Move cursor down
Move cursor down
Move cursor to home position
Move cursor to home position
Move cursor to left-most position
Move cursor to left-most position
Move cursor to right-most position
Move cursor to bottom position
Move cursor to specified position
1 ≦x≦ 20 ,row position
1 ≦y≦ 2 ,column position
ESC @
CLR
CAN
ESC * n
1B 40
0C
18
1B 2A n
Initialize display
Clear display screen , and clear string mode
Clear cursor line, and clear string mode
Brightness adjustment
1≦n≦4
31
ESC & s n m
1B 26 1 n m [a(p1..pa)]
[a (P1..pa)]x x (m-n+1)
(m-n+1)
Define download characters.
32 ≦ n ≦ m 255
1 ≦a ≦ 5 p1..p5 =row1..row5
ESC ? n 1B 3F n
Deletes download characters.
32 ≦ n ≦ m 255
ESC % n
ESC _ n
ESC f n
ESC c n
ESC = n
1B 25 n
1B 5F n
1B 66 n
1B 63 n
1B 3D n
Select/cancel download character set. n = 0 , Cancel n = 1 , Select
Set cursor on/off n = 1 , cursor on n = 2 , cursor off
Select international fonts set, refer *2
Select code, refer *3
Select peripheral device, display or printer n bit 0 = 1 select printer n bit 1 = 1 select display
32
*REMARK :
*1 The parameter of international fonts set control by command “ESC f n”
Parameter “n” International font set
“A”
“G”
“I”
“J”
“U”
“F”
“S”
“N”
U.S.A.
Germany
Italy
Japan
U.K.
France
Spain
Norway
“W”
“D”
“E”
“L”
“R”
Sweden
Denmark I
Denmark II
Slavonic
Russia
*2 The parameter of the code table control by command “ESC c n”
Parameter “n”
“A”
“J”
“L”
“R”
International font set
Compliance with ASCII code
Compliance with JIS code
Compliance with SLAVONIC code
Compliance with RUSSIA code
33
Command
EOT n
DC3
DC4
CAN
EM
FS
GS
US
RS
BS
HT
LF
CR
DLE
DC1
DC2
ESC d
Code (hex)
04 n
1C
1D
1F
1E
13
14
18
19
08
09
0A
0D
0F
11
12
1B 64
Function Description
Display Dimming n = 20h, 40h, 60h, FFh
Back space
Horizontal tab
Line feed
Carriage return
Display position
Over write display mode
Vertical scroll mode
Cursor on
Cursor off
Clear to end of line
Clear to end of display
Flashing text start
Flashing text end
Reset display
Home and clear display
Change to UTC enhanced mode
34
Command Code (hex)
SI
SO
ESC u A ..CR
0F
0E
1B 75 41 data x m 0D
ESC u B ..CR 1B 75 42 data x m 0D
ESC u D ..CR 1B 75 44 data x m 0D
ESC u E ..CR
ESC u F ..CR
1B 75 45 “hh:mm” 0D
1B 75 46 data x m 0D
ESC u H ..CR 1B 75 48 n m 0D
ESC u I ..CR
ESC RS CR
1B 75 49 data x m 0D
1B 0F 0D
Function Description
Flashing text start
Flashing text stop
Upper line display
0 ≦ m ≦ 20
Bottom line display
0 ≦ m ≦ 20
Upper line message scroll continuously
0 ≦ m ≦40
Display time
‟00‟≦ hh ≦ „23‟
‟00‟≦ mm ≦ „59‟
Upper line message scroll once pass
Change attention code
32 ≦ n ≦ 255
32 ≦ m ≦ 255
Two line display
0 ≦ m ≦ 40
Change to UTC standard mode
35
Command Code (hex)
! # 1 ....CR 21 23 31 data x m 0D
! # 2 ....CR
! # 4 ....CR
! # 5 ....CR 21 23 35 “hh:mm” 0D
! # 6 ....CR
! # 8 ....CR
! # 9 ....CR
21 23 32 data x m 0D
21 23 34 data x m 0D
21 23 36 data x m 0D
21 23 38 n m 0D
21 23 39 data x m 0D
Function Description
Upper line display
0 ≦ m ≦ 40
Bottom line display
0 ≦ m ≦ 40
Upper line message scroll continuously
0 ≦ m ≦ 40
Display time
„00‟≦ hh ≦ „23‟
‟00‟≦ mm ≦ „59‟
Upper line message scroll one pass
0 ≦ m ≦ 40
Change attention code
32 ≦n ≦255
32 ≦ m ≦ 255
Two line display
0 ≦ m ≦ 40
36
DC2
DC1
EOT
BS
HT
LF
CR
DLE
Command
09
0A
0D
10
12
11
04
08
Code (hex) Function Description
Vertical Scroll Mode
Normal Display Mode
Brightness Control
Back Space
Horizontal Tab
Line Feed
Carriage Return
Digit Select
DC3
DC4
US
ETX
13
14
1F
03
Cursor On
Cursor Off
Reset
Down Load Font
ENQ d1~d45 CR 05 d1~d45 0D Message Scroll
SOH 01 Data to Peripheral
! # STX 21 23 02 Data to Display
37
Command Code (hex)
CLR
CR
SLE1
SLE2
0C
0D
0E
0F
DC0 n
DC1 n
DC2 n
SF1
SF2
10 n
11 n
12 n
1E
1F
Function Description
Clear display
Carriage return
Clear up line and move cursor to upper line left most end
Clear low line and move cursor to lower line left most end
Set period to upper line last n position
31H ≦ n ≦ 44H
Set line blanking , n = 31H up line n = 32H low line
Clear line blanking , n = 31H up line n = 32H low line
Clear field 1 and move cursor to field 1 fast position
Clear field 2 and move cursor to field 2 fast position
38
Command
EOT SOH I n ETB
EOT SOH P n ETB
EOT SOH C n m ETB
EOT SOH S n ETB
EOT SOH D n m ETB
EOT SOH A n ETB
EOT SOH F n ETB
EOT SOH & n [px5] ETB
EOT SOH ? n ETB
EOT SOH = n ETB
EOT SOH % ETB
EOT SOH @ ETB
Code (hex) Function Description
04 01 49 n 17 Select international character set.
04 01 50 n 17
Move cursor to specified position.
31H ≦ n ≦ 58H
Clear display range from n position to
04 01 43 n m 17 m position and move cursor to n position.
31H ≦ n ≦ m ≦ 58H
04 01 53 n 17
Save the current displaying data to n layer for demo display.
31H ≦n ≦ 33H
Refer*1
Display the saved data
04 01 44 n m 17
31H ≦ n ≦ 37H
31H ≦ m ≦ 37H
Refer*2
04 01 41 n 17
04 01 46 n 17
04 01 26 n p1...p5 17
Brightness adjustment.
31H ≦ n ≦ 34H
Blink display screen.
0 ≦ n ≦ 255
Define download characters
20H < n ≦ FFH
04 01 3F n 17
04 01 3D n 17
04 01 25 17
04 01 40 17
Delete download characters.
20H < n ≦ FFH
Select peripheral device. n = 31H,select printer n = 32H,select display
Initialize display
Execute self-test
39
*REMARK :
*1 Using commands “EOT SOH S n ETB”, the value (Hex) of parameter. n Layer
31h Save data in layer 1
32h Save data in layer 2
33h Save data in layer 3
*2 Using commands “EOT SOH D n m ETB”, the value (Hex) of parameter.
WinPOS extended “select mode” from 33h to 37h n Select layer
31h Demo layer 1
32h Demo layer 2
33h Demo layer 3
34h Demo layer 1 + 2
35h Demo layer 1 + 3 m Select mode
31h Demo mode 1
32h Demo mode 2
33h Demo mode 3
34h Demo mode 1 + 2
35h Demo mode 1 + 3
36h Demo layer 2 + 3 36h Demo mode 2 + 3
37h Demo layer 1 + 2 + 3 37h Demo mode 1 + 2 + 3
40
HT
BS
US LF
LF
US CR
CR
HOM
US B
Command Code (hex)
09
08
1F0A
0A
1F 0D
0D
0B
1F 42
US $ x y
CLR
CAN
US X n
US E n
ESC @
ESC t n
ESC R n
US r n
US MD1
US MD2
US MD3
ESC & s n m
[a(p1..pa)]x m-n
ESC ?
1F 24 x y
0C
18
1F 58 n
1F 45 n
1B 40
1B 74 n
1B 52 n
1F 72 n
1F 01
1F 02
1F 03
1B 26 1 n m
[a(p1..pa)]x m-n
1B 3F n
Function Description
Move cursor right.
Move cursor left.
Move cursor up.
Move cursor down.
Move cursor to right-most position.
Move cursor to left-most position.
Move cursor to home position.
Move cursor to bottom position.
Move cursor to specified position.
1 ≦ x ≦ 20
1 ≦ y ≦ 2
Clear display screen.
Clear cursor line
Brightness adjustment.
1 ≦ n ≦ 4
Blink display screen.
0 ≦ n ≦ 255
Initialize display.
Select character code table.
0 ≦ n ≦ 7, 12, 16, 19, 40
Refer*2
Select international character set.
0 ≦ n ≦ 10
Refer*1
Select/cancel reverse character.
0 ≦ n ≦ 1
Specify overwrite mode.
Specify vertical scroll mode.
Specify horizontal scroll mode.
Define download characters.
32 ≦ n ≦ 255
1≦ a ≦ 5 p1..p5 =row1..row5
Delete downloads characters.
32 ≦ n ≦ 255
41
ESC %
ESC = n
US :
US ^ n m
US @
US T h m
US U
US C n
1B 25 n
1B 3D n
1F3A
1F 5E n m
1F 40
1F 54 h m
1F 55
1F 43 n
*REMARK :
*1 Select international character set n
0
International font
U.S.A.
1
2
France
Germany
3
4
5
6
7
*2 Select character code table
U.K.
Denmark I
Sweden
Italy
Spain n Code table n
0 Page 0, (PC437,USA standard Euro.) 6
1
2
Page 1,(Katakana for Japan)
Page 2,(PC850,Multilingual)
7
19
11
12
13
14
15
3
4
5
Page 3,(PC860, Portuguese)
Page 4,(PC863,Canadian-French)
Page 5,(PC865,Nordic) n
8
9
10
16
12
Select/cancel download character set. n = 0 , Cancel n = 1 , Select
Select peripheral device. n bit 0 = 1 select printer n bit 1 = 1 select display
Set starting/ending position of macro definition.
Execute and quit macro.
0 ≦n≦255 , 0 ≦m≦255
Execute self-test.
Display time
0 ≦h≦23 , 0≦m≦59
Display time continuously
Select / cancel cursor display n = 1 , cursor on n = 0 , cursor off
International font
Japan
Norway
Denmark II
Slavonic
Russia
Portuguese
Greek
Reserved
Code table
Page 6,(Slavonic)
Page 7,(Russia)
Page 19,(PC858, Euro)
Page 16,(WPC1252)
Page 12,(Greek)
42
40H
50H
60H
70H
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
20H
30H
43
Country\Hex 23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E
U.S.A
France
Germany
U.K
Denmark I
Sweden
Italy
Spain
Japan
Norway
Denmark II
Slavonic
Russia
44
80H
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
90H
A0H
B0H
C0H
D0H
E0H
F0H
45
80H
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
90H
A0H
B0H
C0H
D0H
E0H
F0H
46
80H
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
90H
A0H
B0H
C0H
D0H
E0H
F0H
47
80H
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
90H
A0H
B0H
C0H
D0H
E0H
F0H
48
80H
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
90H
A0H
B0H
C0H
D0H
E0H
F0H
49
80H
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
D0H
E0H
F0H
90H
A0H
B0H
C0H
50
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
80H
90H
A0H
B0H
C0H
D0H
E0H
F0H
51
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
80H
C0H
D0H
E0H
F0H
90H
A0H
B0H
52
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
80H
90H
A0H
B0H
C0H
D0H
E0H
F0H
53
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
80H
C0H
D0H
E0H
F0H
90H
A0H
B0H
54
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
80H
90H
A0H
B0H
C0H
D0H
E0H
F0H
55
80H
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
90H
A0H
E0H
F0H
B0H
C0H
D0H
56
F0H
C0H
D0H
E0H
90H
A0H
B0H
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
80H
57
C0H
D0H
E0H
90H
A0H
B0H
F0H
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
80H
58
Advertisement
Touchscreen interface
Intel® Bay Trial-M SoC Processor J1900
Compact design
Variety of connectivity options
Supports cash drawer and customer display
VESA mounting interface
The YUNO 151 has a 15.0" screen and the YUNO 156 has a 15.6" screen.
They support 1 x SO-DIMM DDR3L 1067/1333MHz, Max 8GB of system memory.
They support Windows® 7 Professional for Embedded Systems, Windows® Embedded POSReady 7, and Windows® Embedded 8 Industry Retail.
The YUNO 151 is 360.1 x 171.5 x 316.1 mm and the YUNO 156 is 402.2 x 171.5 x 295.3 mm.
What is the function of the System Cover Release Button?
The System Cover Release Button is used to unlock and open the system cover of the device.
How can the power supply voltage of the cash drawer port be adjusted?
To adjust the power supply voltage for the RJ12 cash drawer port, you need to modify the position of Jumper JP7 on the system's mainboard. Ensure the device is fully powered off and disconnected. Open the system cover. Locate Jumper JP7 ('RJ12 Cash drawer Power Select'). For +19V (default), set the jumper to pins 1-2. For +12V, set the jumper to pins 2-3. Reattach the system cover before reconnecting and powering on the device.
What voltage does a cash drawer require, and why might some cash drawers not work with 'xcashdemo'?
The voltage a cash drawer requires depends on its specific model, typically 12V or 24V. The YUNO system supports both types. The output voltage can be configured via Jumper JP7 on the mainboard: +19V (default) is typically used for 24V cash drawers, as 19V is sufficient to trigger the opening mechanism. +12V must be selected for pure 12V cash drawers. Reasons why cash drawers might not work with 'xcashdemo' include: 1. Incorrect Jumper Setting (Voltage): If a 24V drawer is set to +12V, the solenoid may not have enough power to open it. If a 12V drawer is set to +19V, it could block or damage the coil mechanism. 2. Incorrect I/O address in the demo program: The YUNO system controls the cash drawer via I/O address 48Ch (Register address). Ensure 'xcashdemo' accesses this specific address (e.g., by sending command O 48C 04 to open).
Login to continue