advertisement
HYW
SERIES
Power Range
Standby
Prime kW
17.5
15.8
MODEL:
HYW - 20 M6
STANDARD EQUIPMENT
Open Type Set
■ Skid with integral day fuel tank (non-UL)
■ HIPOWER digital auto-start control panel (Page 4)
■ Dry-type replaceable element air-cleaner
Accessories Available for HYW-20 M6
Mechanical Accessories Offered
■ Road towing trailers to DOT standards
■ Critical grade exhaust mufflers
■ Industrial muffler
■ Battery, battery rack, and cables
■ UL double wall fuel tanks to customer specification
■ Oil field type skid
■ Fuel and lubrication oil replaceable element filters ■ Flexible exhaust connection for open sets
■ Stamford AVR brushless 12-wire reconnectable alternator ■ Oil pressure and engine temperature gauges
■ Oil drain hand pump
■ Vibration Isolators between base and set assembly
■ Main Line Circuit Breaker for overload protection
■ Belt driven charging alternator
■ Water Jacket heater
■ Extended warranty coverage period
■ Guards for shielding all rotating parts
■ Fuel cut-off solenoid and protection switches
■ Radiator with pusher fan
■ Operation and installation manuals
Generator End Accessories Offered
■ Anti-condensation heaters in alternator
Electrical and Control Accessories Offered
■ Automatic battery chargers 1.5 and 6 amp
Sound Attenuated Enclosure ■ NFPA 110 controls and remote annunciator
■ Fully sound attenuated enclosure (equipped as open set) ■ Transfer switch and paralleling control panels
■ Powder Painted with finish that exceeds 1000-hr salt test ■ Remote control from PC via hard and/or wireless link
■ Rock wool insulation behind protective barrier ■ Digital Timer
■ Curved edges and minimum outside fasteners
■ Single lifting point
GENERATOR RATINGS
Alternator
BCI 1 84 E
Voltage
120 / 240
Ph
1
Hz
60
Standby Rating kW Amps
17.5 73
Prime Rating kW
15.8
Amps
66
Application Data
Manufacturer
Alternator Specifications
Newage Stamford
Engine Mechanical Specifications
Manufacturer Yanmar
Type
Exciter type
Leads: quantity, type
Voltage regulator
4-pole, rotating field
Brushless, self excited. (PMG option)
12, reconnectable
Solid state, volts/Hz and excitation overload protection
Engine model
Engine type
Cylinder arrangement
EPA Certification :
4TNV88
4-cycle, Naturally aspirated
4 in line
TIER 3
Insulation:
Material......................
Temperature rise..........
Bearing: quantity, type
Coupling
Amortisseur Windings
Voltage regulation, no-load to full load
Unbalanced load capability
Load acceptance
Peak motor starting kVA:
480 V
Class H
125° C , standby
Single bearing sealed
Flexible disc
Full
± 1.5%
100% of rated standby current
Per ISO - 8528
(30% dip) self-excited series - 41 kVA
Displacement, L (cu. in.)
Bore and stroke, mm (in.)
Compression ratio
Piston speed, m/min. (ft./min.)
Main bearings: quantity, type
Rated rpm
Max. power at rated rpm, kWm
(BHP)
BMEP, gross, psi ( Bar )
Overall thermal efficiency
2.19 (134)
88 x 90 (3.46 x 3.54)
19.1 : 1
324 (1063)
5, replaceable insert
1,800
22.5 (30.2)
99.5 (6.86)
34.4.%
Engine Electrical Specifications
Exhaust Gas Flow, m³ /min (cfm)
Exhaust gas temperature °C (°F)
5.96 (210.6)
550 (1022)
4.5%
Engine Electrical System (12 Volt) 60 Hz
Battery charging alternator:
Ground (negative/positive).
Volts (DC).........................
Ampere rating..................
Starter motor rated voltage (DC)
Starter motor rated kW:
Battery CCA rating:
Battery & qty, AH rating:
Negative
12V
40A
12V
1.4Kw
780A
1 x 66 AH
Battery Voltage (DC) 12V
Remote Radiator System
Exhaust manifold type
Connection sizes:
Water inlet ID hose, mm (in)
Water outlet ID hose, mm (in)
Charge air cooling (CAC)
Water inlet ID hose, mm (in)
Water outlet ID hose, mm (in)
Static head allowable above engine, ft.H²O (kPa)
Maximum CAC restriction H²O in.
Not Available
Contact the HIPOWER distributor for special cooling options
Frequency regulation, no-load to full load
Governor: Type:
Make:
Standard:
Frequency regulation, steady state
Frequency
Mechanical
Yanmar
±0.4%
Fixed
Air cleaner type Dry
Fuel Consumption 60 Hz
Diesel gal/hr (L/hr) Standby Rating
100% 1.72 (6.5)
75%
50%
25%
Diesel gal/hr (L/hr)
100%
1.38 (5.2)
1.03 (3.9)
0.60 (2.3)
Prime Power Rating
1.57 (5.9)
75%
50%
25%
1.26 (4.8)
0.94 (3.6)
0.55 (2.1)
Cooling
Radiator Systems
Ambient temperature, °C (°F)
Engine jacket water capacity L (gal)
Radiator system capacity, including engine, L (gal.)
Engine jacket water flow, L/min (g/min)
Heat rejected to cooling water at rated kW, dry exhaust, kW (Btu/min.)
Water pump type
Fan, kWm (HP)
Max. restriction of cooling air, intake and discharge side of radiator, Pa (in. H²O)
Application Data
60 Hz
NA Type
Lubrication
Lubricating System
2.7 (0.71)
NA
34 (9.0)
Oil pan capacity, L, (qt.)
Recommended lube oil
Oil pan capacity with filter, L (qt.)
Oil filter: quantity, type
14.0 (797)
Centrifugal
0.9 (1.2)
60 Hz
Full pressure
7.4 (7.8)
SAE15W40 , API CF-4
NA
1, cartridge
Oil cooler
Maximum oil temperature, ºC(ºF)
None
120 (248)
Ventilation and Air-Flow Requirements
Air Requirements 60 Hz
Radiator-cooled cooling air, m³/min. (scfm) NA
Air density kg/m³ (ibm/ft³) 1.20 (0.075)
62.2 (0.25)
Heat rejected to exhaust, kW (btu/min) 24.2 (1377)
dB(A) LEVEL SOUND ATTENUATED ENCLOSED 60 dB(A) @ 23 feet
Heat radiated to surrounding air Engine: kW (Btu)
Combustion air, m³/min. (cfm)
3.8 (216)
1.77 (62.8)
Dimensions and Weights
Open Skid Model
Overall size, L x W x H, mm (ins.) 1,450 x 620x 1,280
(57.1 x 24.4 x 50.4)
Weight, radiator-mounted model, wet, kg (lb.): 455 (1003)
Fuel Tank Capacity, L (US gal) 72 (19)
Sound Attenuated Enclosure
Overall size, L x W x H, mm (ins.) 2,250 x 1100 x 1,340
Weight, radiator-mounted model, kg (lb.):
Fuel Tank Capacity, L (US gal)
(88.6 x 43.3 x 52.8)
975 (2,150)
100 (26.4)
H H
W L W L
NOTE: The drawings above are only representative of the overall dimensions. For full detailed installation drawings please consult your local distributor or contact Himoinsa Power Systems @ www.hipowersystems.com
RATINGS: Power factor three-phase is 0.8 and single-phase unity. Standby Ratings: Standby ratings assume installation normally served by reliable utility power. The standby rating is available for varying loads for the length of the power outage. No overload is available with the standby rating. Ratings are in accordance with ISO-3046/1 and DIN 6271.
Prime Power Ratings: Prime power ratings assume no or unreliable utility power. For varying loads the generator set has unlimited operating hours. A 10% overload capacity is available for any 1 hour in a 12 hour continous running period. Ratings are in acoordance with ISO-3046/1 and DIN 6271. Consult Himoinsa for limited running time and base load ratings. Himoinsa reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. DERATION GUIDELINES: Altitude:
Derate 1.3% per 100 m (328 ft) elevation above 1000 m (3280 ft). Temperature: Derate 1.0% per 10ºC (18ºF) temperature above 40ºC (104ºF).
HIPOWER CEM6 Auto Start Digital Controller
CONTROLLER DISPLAY :
1.
Voltage between each Phase & Neutral
2.
Voltage between Phases
3.
Current (amps) on each Phase
4.
Frequency
5.
Active, Aparent & Reactive Power
6.
Power Factor
7.
Instant Power (KwH) and Accumulative power (day, month & year)
8. Fuel reserve
9.
Oil pressure, coolant temperature
10. Battery voltage, battery charging alternator voltage
11. Engine Speed
12. Hours running
ENGINE ALARMS :
1.
High coolant temperature
2.
Low oil pressure
3.
Emergency stop
Distributor:
6.
7.
4.
5.
8.
9.
7.
8.
5.
6.
9.
1.
2.
3.
4.
Battery charging alternator failure
Low coolant level
Low fuel level
Over speed
Under speed
Battery low voltage
GENERATOR ALARMS :
Over-load
Unbalanced voltage
Over-voltage
Under-voltage
Over-frequency
Under-frequency
Short-circuit
Inverse Power
Incorrect phase sequence
Himoinsa Power Systems, Inc. ▪ 16210 West 110th Street, Lenexa, KS 66219 ▪ Tel: 913-495-5557 ▪ Fax: 913-495-5575
www.hipowersystems.com
advertisement