Diesel-Generator-HYW-20-M6


Add to my manuals
4 Pages

advertisement

Diesel-Generator-HYW-20-M6 | Manualzz

HYW

SERIES

Power Range

Standby

Prime kW

17.5

15.8

MODEL:

HYW - 20 M6

STANDARD EQUIPMENT

Open Type Set

■ Skid with integral day fuel tank (non-UL)

■ HIPOWER digital auto-start control panel (Page 4)

■ Dry-type replaceable element air-cleaner

Accessories Available for HYW-20 M6

Mechanical Accessories Offered

■ Road towing trailers to DOT standards

■ Critical grade exhaust mufflers

■ Industrial muffler

■ Battery, battery rack, and cables

■ UL double wall fuel tanks to customer specification

■ Oil field type skid

■ Fuel and lubrication oil replaceable element filters ■ Flexible exhaust connection for open sets

■ Stamford AVR brushless 12-wire reconnectable alternator ■ Oil pressure and engine temperature gauges

■ Oil drain hand pump

■ Vibration Isolators between base and set assembly

■ Main Line Circuit Breaker for overload protection

■ Belt driven charging alternator

■ Water Jacket heater

■ Extended warranty coverage period

■ Guards for shielding all rotating parts

■ Fuel cut-off solenoid and protection switches

■ Radiator with pusher fan

■ Operation and installation manuals

Generator End Accessories Offered

■ Anti-condensation heaters in alternator

Electrical and Control Accessories Offered

■ Automatic battery chargers 1.5 and 6 amp

Sound Attenuated Enclosure ■ NFPA 110 controls and remote annunciator

■ Fully sound attenuated enclosure (equipped as open set) ■ Transfer switch and paralleling control panels

■ Powder Painted with finish that exceeds 1000-hr salt test ■ Remote control from PC via hard and/or wireless link

■ Rock wool insulation behind protective barrier ■ Digital Timer

■ Curved edges and minimum outside fasteners

■ Single lifting point

GENERATOR RATINGS

Alternator

BCI 1 84 E

Voltage

120 / 240

Ph

1

Hz

60

Standby Rating kW Amps

17.5 73

Prime Rating kW

15.8

Amps

66

Application Data

Manufacturer

Alternator Specifications

Newage Stamford

Engine Mechanical Specifications

Manufacturer Yanmar

Type

Exciter type

Leads: quantity, type

Voltage regulator

4-pole, rotating field

Brushless, self excited. (PMG option)

12, reconnectable

Solid state, volts/Hz and excitation overload protection

Engine model

Engine type

Cylinder arrangement

EPA Certification :

4TNV88

4-cycle, Naturally aspirated

4 in line

TIER 3

Insulation:

Material......................

Temperature rise..........

Bearing: quantity, type

Coupling

Amortisseur Windings

Voltage regulation, no-load to full load

Unbalanced load capability

Load acceptance

Peak motor starting kVA:

480 V

Class H

125° C , standby

Single bearing sealed

Flexible disc

Full

± 1.5%

100% of rated standby current

Per ISO - 8528

(30% dip) self-excited series - 41 kVA

Displacement, L (cu. in.)

Bore and stroke, mm (in.)

Compression ratio

Piston speed, m/min. (ft./min.)

Main bearings: quantity, type

Rated rpm

Max. power at rated rpm, kWm

(BHP)

BMEP, gross, psi ( Bar )

Overall thermal efficiency

2.19 (134)

88 x 90 (3.46 x 3.54)

19.1 : 1

324 (1063)

5, replaceable insert

1,800

22.5 (30.2)

99.5 (6.86)

34.4.%

Engine Electrical Specifications

Exhaust Gas Flow, m³ /min (cfm)

Exhaust gas temperature °C (°F)

5.96 (210.6)

550 (1022)

4.5%

Engine Electrical System (12 Volt) 60 Hz

Battery charging alternator:

Ground (negative/positive).

Volts (DC).........................

Ampere rating..................

Starter motor rated voltage (DC)

Starter motor rated kW:

Battery CCA rating:

Battery & qty, AH rating:

Negative

12V

40A

12V

1.4Kw

780A

1 x 66 AH

Battery Voltage (DC) 12V

Remote Radiator System

Exhaust manifold type

Connection sizes:

Water inlet ID hose, mm (in)

Water outlet ID hose, mm (in)

Charge air cooling (CAC)

Water inlet ID hose, mm (in)

Water outlet ID hose, mm (in)

Static head allowable above engine, ft.H²O (kPa)

Maximum CAC restriction H²O in.

Not Available

Contact the HIPOWER distributor for special cooling options

Frequency regulation, no-load to full load

Governor: Type:

Make:

Standard:

Frequency regulation, steady state

Frequency

Mechanical

Yanmar

±0.4%

Fixed

Air cleaner type Dry

Fuel Consumption 60 Hz

Diesel gal/hr (L/hr) Standby Rating

100% 1.72 (6.5)

75%

50%

25%

Diesel gal/hr (L/hr)

100%

1.38 (5.2)

1.03 (3.9)

0.60 (2.3)

Prime Power Rating

1.57 (5.9)

75%

50%

25%

1.26 (4.8)

0.94 (3.6)

0.55 (2.1)

Cooling

Radiator Systems

Ambient temperature, °C (°F)

Engine jacket water capacity L (gal)

Radiator system capacity, including engine, L (gal.)

Engine jacket water flow, L/min (g/min)

Heat rejected to cooling water at rated kW, dry exhaust, kW (Btu/min.)

Water pump type

Fan, kWm (HP)

Max. restriction of cooling air, intake and discharge side of radiator, Pa (in. H²O)

Application Data

60 Hz

NA Type

Lubrication

Lubricating System

2.7 (0.71)

NA

34 (9.0)

Oil pan capacity, L, (qt.)

Recommended lube oil

Oil pan capacity with filter, L (qt.)

Oil filter: quantity, type

14.0 (797)

Centrifugal

0.9 (1.2)

60 Hz

Full pressure

7.4 (7.8)

SAE15W40 , API CF-4

NA

1, cartridge

Oil cooler

Maximum oil temperature, ºC(ºF)

None

120 (248)

Ventilation and Air-Flow Requirements

Air Requirements 60 Hz

Radiator-cooled cooling air, m³/min. (scfm) NA

Air density kg/m³ (ibm/ft³) 1.20 (0.075)

62.2 (0.25)

Heat rejected to exhaust, kW (btu/min) 24.2 (1377)

dB(A) LEVEL SOUND ATTENUATED ENCLOSED 60 dB(A) @ 23 feet

Heat radiated to surrounding air Engine: kW (Btu)

Combustion air, m³/min. (cfm)

3.8 (216)

1.77 (62.8)

Dimensions and Weights

Open Skid Model

Overall size, L x W x H, mm (ins.) 1,450 x 620x 1,280

(57.1 x 24.4 x 50.4)

Weight, radiator-mounted model, wet, kg (lb.): 455 (1003)

Fuel Tank Capacity, L (US gal) 72 (19)

Sound Attenuated Enclosure

Overall size, L x W x H, mm (ins.) 2,250 x 1100 x 1,340

Weight, radiator-mounted model, kg (lb.):

Fuel Tank Capacity, L (US gal)

(88.6 x 43.3 x 52.8)

975 (2,150)

100 (26.4)

H H

W L W L

NOTE: The drawings above are only representative of the overall dimensions. For full detailed installation drawings please consult your local distributor or contact Himoinsa Power Systems @ www.hipowersystems.com

RATINGS: Power factor three-phase is 0.8 and single-phase unity. Standby Ratings: Standby ratings assume installation normally served by reliable utility power. The standby rating is available for varying loads for the length of the power outage. No overload is available with the standby rating. Ratings are in accordance with ISO-3046/1 and DIN 6271.

Prime Power Ratings: Prime power ratings assume no or unreliable utility power. For varying loads the generator set has unlimited operating hours. A 10% overload capacity is available for any 1 hour in a 12 hour continous running period. Ratings are in acoordance with ISO-3046/1 and DIN 6271. Consult Himoinsa for limited running time and base load ratings. Himoinsa reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. DERATION GUIDELINES: Altitude:

Derate 1.3% per 100 m (328 ft) elevation above 1000 m (3280 ft). Temperature: Derate 1.0% per 10ºC (18ºF) temperature above 40ºC (104ºF).

HIPOWER CEM6 Auto Start Digital Controller

CONTROLLER DISPLAY :

1.

Voltage between each Phase & Neutral

2.

Voltage between Phases

3.

Current (amps) on each Phase

4.

Frequency

5.

Active, Aparent & Reactive Power

6.

Power Factor

7.

Instant Power (KwH) and Accumulative power (day, month & year)

8. Fuel reserve

9.

Oil pressure, coolant temperature

10. Battery voltage, battery charging alternator voltage

11. Engine Speed

12. Hours running

ENGINE ALARMS :

1.

High coolant temperature

2.

Low oil pressure

3.

Emergency stop

Distributor:

6.

7.

4.

5.

8.

9.

7.

8.

5.

6.

9.

1.

2.

3.

4.

Battery charging alternator failure

Low coolant level

Low fuel level

Over speed

Under speed

Battery low voltage

GENERATOR ALARMS :

Over-load

Unbalanced voltage

Over-voltage

Under-voltage

Over-frequency

Under-frequency

Short-circuit

Inverse Power

Incorrect phase sequence

Himoinsa Power Systems, Inc. ▪ 16210 West 110th Street, Lenexa, KS 66219 ▪ Tel: 913-495-5557 ▪ Fax: 913-495-5575

www.hipowersystems.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

advertisement