SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "DANGER" and "CAUTION".
DANGER
CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Note that the caution level may lead to a serious accident according to the circumstances. Always follow the instructions of both levels because they are important to personal safety.
Please save this manual to make it accessible when required and always forward it to the end user.
[DESIGN PRECAUTIONS]
DANGER
Some failures of the GOT or cable may keep the outputs on or off.
An external monitoring circuit should be provided to check for output signals which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
If a communication fault (including cable disconnection) occurs during monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative.
A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
Do not use the GOT as the warning device that may cause a serious accident.
An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect output or malfunction.
A
- 1
[DESIGN PRECAUTIONS]
DANGER
Incorrect operation of the touch switch(es) may lead to a serious accident if the GOT backlight is gone out.
When the GOT backlight goes out, the monitor screen turns black, while the input of the touch switch(s) remains active.
This may confuse an operator in thinking that the GOT is in "screensaver" mode, who then tries to release the GOT from this mode by touching the display section, which may cause a touch switch to operate.
For GT105 , the following phenomenon occurs when the backlight goes out.
• The POWER LED flickers (green/orange) and the monitor screen appears blank
CAUTION
Do not bundle the control and communication cables with main-circuit, power or other wiring.
Run the above cables separately from such wiring and keep them a minimum of 100mm (3.94in.) apart. Not doing so noise can cause a malfunction.
[MOUNTING PRECAUTIONS]
DANGER
Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to/from the panel.
Not doing so can cause the unit to fail or malfunction.
When installing the battery or memory board wear an earth band etc. to avoid the static electricity.
The static electricity can cause the unit to fail or malfunction.
Be sure to shut off all phases of the external power supply used by the system before mounting or removing the memory board on to/ from the GOT.
Not doing so can cause the unit to fail or malfunction.
CAUTION
Use the GOT in the environment that satisfies the general specifications described in this manual.
Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in the specified torque range.
Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or the
GOT.
Securely connect the memory board to the connector provided for the board.
A
- 2
[WIRING PRECAUTIONS]
DANGER
Be sure to shut off all phases of the external power supply used by the system before wiring.
Failure to do so may result in an electric shock, product damage or malfunctions.
Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT.
Not doing so may cause an electric shock or malfunction.
Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section in the specified torque range.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.
Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT.
Not doing so can cause a fire, failure or malfunction.
CAUTION
Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
[TEST OPERATION PRECAUTIONS]
DANGER
Before performing the test operations of the user creation monitor screen (such as turning ON or
OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter), read through the manual carefully and make yourself familiar with the operation method.
During test operation, never change the data of the devices which are used to perform significant operation for the system.
False output or malfunction can cause an accident.
A
- 3
[STARTUP/MAINTENANCE PRECAUTIONS]
DANGER
When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
Connect the battery correctly.
Do not discharge, disassemble, heat, short, solder or throw the battery into the fire.
Incorrect handling may cause the battery to generate heat, burst or take fire, resulting in injuries or fires.
Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases.
Not switching the power off in all phases can cause a unit failure or malfunction.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
CAUTION
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull the cable portion.
Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.
Do not drop or apply any impact to the battery.
If any impact has been applied, discard the battery and never use it.
The battery may be damaged by the drop or impact.
Before touching the unit, always touch grounded metal, etc. to discharge static electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
[DISPOSAL PRECAUTIONS]
CAUTION
When disposing of the product, handle it as industrial waste.
When disposing of batteries, separate them from other wastes according to the local regulations.
(For details of the battery deirective in EU member states, refer to 18.4
.)
A
- 4
[TRANSPORTATION PRECAUTIONS]
CAUTION
When transporting lithium batteries, make sure to treat them based on the transport regulations.
(Refer to Appendix 3 for details of the regulated units.)
Before transporting the GOT, turn the GOT power on and check that the battery voltage status is normal on the Time setting & display screen (utilities screen). In addition, confirm that the adequate battery life remains on the rating plate.
Transporting the GOT with the low battery voltage or the battery the reached battery life may unstabilize the backup data unstable during transportation.
Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual, as they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
A
- 5
REVISIONS
Print Date
Nov., 2006
Jun, 2007
Dec, 2007
Feb., 2008
Oct., 2008
Dec., 2008
Jan., 2009
Manual Number
JY997D24701
JY997D24701
JY997D24701
JY997D24701
JY997D24701
JY997D24701
JY997D24701
Ver.
A First edition
B
The manual number is given on the bottom left of the back cover.
Revision
Partial correcting
SAFETY PRECAUTIONS, ABBREVIATIONS AND GENERIC TERMS IN
THIS MANUAL, HOW TO READ THIS MANUAL, Section 1.1, 2.2, 3.2, 3.3,
Chapter 4, Section 6.2, 6.3, 7.1, 8.1, 8.2, Chapter 9, Section 11.1, Chapter
12, 13, Section 14.1, Chapter 15, Section 16.2, App - 1, App - 2, App - 4
C
D
E
Additions
Section 8.3, 16.4, App - 3
Partial correcting
SAFETY PRECAUTIONS, ABBREVIATIONS AND GENERIC TERMS IN
THIS MANUAL, HOW TO READ THIS MANUAL, Section 3.2, 9.1, 11.2.3,
Chapter 12, App-4
Partial correcting
ABBREVIATIONS AND GENERIC TERMS IN THIS MANUAL, HOW TO
READ THIS MANUAL, Chapter 2, Section 8.2, Chapter 11, Section 15.2,
App-1, App-4, Index-1
Additions
Section 8.4
Partial correcting
ABBREVIATIONS AND GENERIC TERMS IN THIS MANUAL, HOW TO
READ THIS MANUAL, Chapter 1, Chapter 2, Chapter 3, Chapter 4,
Chapter 5, Chapter 6, Chapter 7, Chapter 8, Chapter 9, Chapter 11,
Chapter 12, Chapter 13, Chapter 14, Chapter 17, Chapter 18, App-1,
App-2, Index
F
G
Additions
Chapter 15, 16
Partial correcting
ABBREVIATIONS AND GENERIC TERMS IN THIS MANUAL, HOW TO
READ THIS MANUAL, Section1.1, Chapter 2, Chapter 3, Chapter 4,
Chapter 5, Chapter 6, Chapter 7, Chapter 8, Chapter 9, Chapter 11,
Chapter 12, Chapter 13, Chapter 14, Chapter 15, Chapter 17, Chapter 18,
App-1, App-2, App-4
Additions
Section11.1.4, Section11.1.5, Section14.3
Partial correcting
Section 7.1.2
A
- 6
Print Date
Mar., 2009
Aug, 2009
Oct, 2009
Manual Number
JY997D24701
JY997D24701
JY997D24701
Ver.
H
Revision
Partial correcting
SAFETY PRECAUTIONS, ABBREVIATIONS AND GENERIC TERMS,
HOW TO READ THIS MANUAL, Chapter 2, Section 3.1, 3.2, Section 4.2,
Section 8.3, Section 9.1, Section 12.1, Section 18.4, App-1, App-2, App-4,
Index
J
K
Additions
Section 8.8, Section 8.9
Partial correcting
ABBREVIATIONS AND GENERIC TERMS, HOW TO READ THIS
MANUAL, Section 2.2, Chapter 3, Chapter 4, Chapter 5, Section 7.1,
Section 8.8, Section 11.1, App-4
Partial correcting
ABBREVIATIONS AND GENERIC TERMS, ABOUT MANUALS, HOW TO
READ THIS MANUAL, Chapter 1, Section 2.2, Chapter 3, Chapter 8,
Chapter 9, Chapter 11, Chapter 12, Chapter 15, Chapter 17, Chapter 18,
App-2
Additions
Section 11.1.6, Section11.1.7, Section 15.3
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses.
Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
© 2006 MITSUBISHI ELECTRIC CORPORATIONs
A
- 7
INTRODUCTION
Thank you for choosing the Mitsubishi Graphic Operation Terminal.
Before using the equipment, please read this manual carefully to use the equipment to its optimum.
OUTLINE PRECAUTIONS
• This manual provides information for the use of the graphic operation terminal. The manual has been written to be used by trained and competent personnel. The definition of such a person or persons is as follows;
1) Any engineer who is responsible for the planning, design and construction of automatic equipment using the product associated with this manual should be of a competent nature, trained and qualified to the local and national standards required to fulfill that role. These engineers should be fully aware of all aspects of safety with regards to automated equipment.
2) Any commissioning or service engineer must be of a competent nature, trained and qualified to the local and national standards required to fulfill that job. These engineers should also be trained in the use and maintenance of the completed product. This includes being completely familiar with all associated documentation for the said product. All maintenance should be carried out in accordance with established safety practices.
3) All operators of the completed equipment should be trained to use that product in a safe and coordinated manner in compliance to established safety practices. The operators should also be familiar with documentation which is connected with the actual operation of the completed equipment.
Note: the term 'completed equipment' refers to a third party constructed device which contains or uses the product associated with this manual.
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi Electric.
• This product has been manufactured under strict quality control. However when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
• When using this product combining other products, please confirm the standard and the code, or regulation which a user should suit. Moreover, please confirm the compatibility of this product to the system, machine, and apparatus with which a user is used for user itself.
• If in doubt at any stage of the installation of the product always consult a professional electrical engineer who is qualified and trained to the local and national standards. If in doubt about the operation or use, please consult the nearest Mitsubishi Electric distributor.
• Since the example indicated by this manual, technical bulletin, the catalog, etc. is reference, please use it after confirming the function and safety of equipment and system when employing. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
• About this manual content, specification etc. may be changed without a notice for improvement.
• The information in this manual has been carefully checked and is believed to be accurate; however, you have noticed a doubtful point, a doubtful error, etc., please contact the nearest Mitsubishi Electric distributor.
A - 8
CONTENTS
1. OVERVIEW.......................................................... 1-1 to 1-5
2. SYSTEM CONFIGURATION ............................. 2-1 to 2-11
3. SPECIFICATIONS ............................................. 3-1 to 3-15
4. PART NAME...................................................... 4-1 to 4-12
5. EMC DIRECTIVE ................................................. 5-1 to 5-3
A - 9
6. INSTALLATION..................................................6-1 to 6-11
7. WIRING.................................................................7-1 to 7-9
8. OPTION ..............................................................8-1 to 8-24
A - 10
9. UTILITY FUNCTION ............................................ 9-1 to 9-7
10. LANGUAGE SETTING (Language)........................... 10-1
11. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)................... 11-1 to 11-24
A - 11
12. DISPLAY AND OPERATION SETTINGS (GOT SET UP)
............................................................................12-1 to 12-16
13. CLOCK SETTINGS AND BATTERY STATUS DISPLAY
(TIME SETTING AND DISPLAY) ...................13-1 to 13-2
14. FILE DISPLAY (DATA) ................................14-1 to 14-10
15. GOT DEBUG ................................................15-1 to 15-42
A - 12
16. CLEANING OF DISPLAY SECTION (CLEAN) .......... 16-1
17. OS INSTALLATION....................................... 17-1 to 17-4
17.3 Standard Monitor OS/Communication Driver Installation Using Memory Board .... 17-3
18. MAINTENANCE AND INSPECTION............. 18-1 to 18-6
APPENDICES............................................ App-1 to App-19
Appendix 4 List of Functions Added by GT Designer2 Version Upgrade (For GOT1000
INDEX .......................................................Index-1 to Index-2
A - 13
ABOUT MANUALS
The following manuals are also related to this product.
In necessary, order them by quoting the details in the tables below.
Related Manuals
Manual Name
Manual Number
(Model Code)
GT Designer2 Version2 Basic Operation/Data Transfer Manual (For GOT1000 Series)
Describes methods of the GT Designer2 installation operation, basic operation for drawing and transmitting data to GOT1000 series
(Sold separately)
*1
GT Designer2 Version2 Screen Design Manual (For GOT1000 Series) 1/3
GT Designer2 Version2 Screen Design Manual (For GOT1000 Series) 2/3
GT Designer2 Version2 Screen Design Manual (For GOT1000 Series) 3/3
Describes specifications and settings of the object functions used in GT Designer2
(Sold separately)
*1
GOT1000 Series Connection Manual (1/3, 2/3, 3/3)
Describes system configurations of the connection method applicable to GOT1000 series and cable creation method
(Sold separately)
*1
GT Designer3 Version1 Screen Design Manual (For GOT1000 Series) (Fundamentals)
Describes methods of the GT Designer3 installation operation, basic operation for drawing and transmitting data to GOT1000 series
(Sold separately)
*1
GT Designer3 Version1 Screen Design Manual (For GOT1000 Series) (Functions) 1/2
GT Designer3 Version1 Screen Design Manual (For GOT1000 Series) (Functions) 2/2
Describes methods of the GT Designer3 installation operation, basic operation for drawing and transmitting data to GOT1000 series
(Sold separately)
*1
GOT1000 Series Connection Manual (Mitsubishi Products)
Describes system configurations of the connection method applicable to GOT1000 series and cable creation method
(Sold separately)
*1
GOT1000 Series Connection Manual (Non-Mitsubishi Products 1)
Describes system configurations of the connection method applicable to GOT1000 series and cable creation method
(Sold separately)
*1
SH-080529ENG
(1D7M24)
SH-080530ENG
(1D7M25)
SH-080532ENG
(1D7M26)
SH-080866ENG
(1D7MB9)
SH-080867ENG
(1D7MC1)
SH-080868ENG
(1D7MC2)
SH-080869ENG
(1D7MC3)
GOT1000 Series Connection Manual (Non-Mitsubishi Products 2)
Describes system configurations of the connection method applicable to GOT1000 series and cable creation method
(Sold separately)
*1
GOT1000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals)
Describes system configurations of the connection method applicable to GOT1000 series and cable creation method
(Sold separately)
*1
SH-080870ENG
(1D7MC4)
SH-080871ENG
(1D7MC5)
*1 The manual in PDF-format is included in the GT Works2, GT Designer2, GT Works3 and GT Designer3 products.
A - 14
ABBREVIATIONS AND GENERIC TERMS
Abbreviations and generic terms used in this manual are as follows:
GOT
Abbreviations and generic terms
GT SoftGOT1000
GOT1000 Series
GOT900 Series
GOT800 Series
GT1695
GT1685
GT1675
GT1665
GT1695M-X
GT1685M-S
GT1675M-S
GT1675M-V
GT1665M-S
GT1665M-V
GT16
GT1595
, GT16
GT1595-X
GT1585
GT1585V-S
GT1585-S
GT157
GT1575V-S
GT1575-S
GT1575-V
GT1575-VN
GT156
GT155
GT1572-VN
GT1565-V
GT1562-VN
GT1555-V
GT1555-Q
GT1550-Q
Description
Abbreviation of GT SoftGOT1000
Abbreviation of GT1695M-XTBA, GT1695M-XTBD
Abbreviation of GT1685M-STBA, GT1685M-STBD
Abbreviation of GT1675M-STBA, GT1675M-STBD
Abbreviation of GT1675M-VTBA, GT1675M-VTBD
Abbreviation of GT1665M-STBA, GT1665M-STBD
Abbreviation of GT1665M-VTBA, GT1665M-VTBD
Abbreviation of GT1695,GT1685, GT1675, GT1665
Abbreviation of GT1595-XTBA, GT1595-XTBD
Abbreviation of GT1585V-STBA, GT1585V-STBD
Abbreviation of GT1585-STBA, GT1585-STBD
Abbreviation of GT1575V-STBA, GT1575V-STBD
Abbreviation of GT1575-STBA, GT1575-STBD
Abbreviation of GT1575-VTBA, GT1575-VTBD
Abbreviation of GT1575-VNBA, GT1575-VNBD
Abbreviation of GT1572-VNBA, GT1572-VNBD
Abbreviation of GT1565-VTBA, GT1565-VTBD
Abbreviation of GT1562-VNBA, GT1562-VNBD
Abbreviation of GT1555-VTBD
Abbreviation of GT1555-QTBD, GT1555-QSBD
Abbreviation of GT1550-QLBD
GT15
GT115
Handy
GOT
GT11
GT105
GT104
GT1030
GT1020
, GT15 Abbreviation of GT1595, GT1585, GT157 , GT156 , GT155
GT1155-Q
Abbreviation of GT1155-QTBDQ, GT1155-QSBDQ, GT1155-QTBDA, GT1155-QSBDA,
GT1155-QTBD, GT1155-QSBD
Abbreviation of GT1150-QLBDQ, GT1150-QLBDA, GT1150-QLBD GT1150-Q
GT1155HS-Q Abbreviation of GT1155HS-QSBD
GT1150HS-Q Abbreviation of GT1150HS-QLBD
, GT11
Abbreviation of GT1155-Q, GT1150-Q, GT11 Handy GOT
GT1055-Q
GT1050-Q
GT1045-Q
GT1040-Q
Abbreviation of GT1055-QSBD
Abbreviation of GT1050-QBBD
Abbreviation of GT1045-QSBD
Abbreviation of GT1040-QBBD
Abbreviation of GT1030-LBD, GT1030-LBD2, GT1030-LBL, GT1030-LBDW, GT1030-
LBDW2, GT1030-LBLW, GT1030-LWD, GT1030-LWD2, GT1030-LWL, GT1030-LWDW,
GT1030-LWDW2, GT1030-LWLW
Abbreviation of GT1020-LBD, GT1020-LBD2, GT1020-LBL, GT1020-LBDW, GT1020-
LBDW2, GT1020-LBLW, GT1020-LWD, GT1020LWD2, GT1020-LWL, GT1020-LWDW,
GT1020-LWDW2, GT1020-LWLW
GT10 , GT10 Abbreviation of GT105 , GT104 , GT1030, GT1020
Abbreviation of GOT-A900 series, GOT-F900 series
Abbreviation of GOT-800 series
A - 15
Communication unit
Abbreviations and generic terms
Bus connection unit
Serial communication unit
RS-422 conversion unit
Ethernet communication unit
MELSECNET/H communication unit
GT15-QBUS2,
GT15-75QBUS2L, GT15-75ABUSL,
GT15-RS4-9S,
GT15-RS2T4-25P
Description
GT15-QBUS,
GT15-75QBUSL,
GT15-RS2-9P,
GT15-RS2T4-9P,
GT15-J71E71-100
GT15-J71LP23-25, GT15-J71BR13
GT15-75J71LP23-Z
*1
, GT15-75J71BR13-Z
*2
GT15-ABUS,
GT15-RS4-TE
MELSECNET/10 communication unit
CC-Link IE controller network communication unit
CC-Link communication unit
GT15-J71GP23-SX
CC-Link interface unit
Interface converter unit
Serial multi-drop connection unit
Connection Conversion Adapter
GT15-J61BT13,
GT11HS-CCL
GT15-75IF900
GT01-RS4-M
GT10-9PT5S
*1 A9GT-QJ71LP23 + GT15-75IF900 set
*2 A9GT-QJ71BR13 + GT15-75IF900 set
*3 A8GT-J61BT13 + GT15-75IF900 set
GT15-75J61BT13-Z
*3
Option unit
Abbreviations and generic terms
Printer unit
Video input unit
RGB input unit
Video/RGB unit
Video/RGB input unit
RGB output unit
Multimedia unit
CF card unit
GT15-PRN
GT16M-V4,
GT16M-R2,
GT16M-V4R1,
GT16M-ROUT,
GT16M-MMR
GT15-CFCD
GT15V-75V4
GT15V-75R1
GT15V-75V4R1
GT15V-75ROUT
CF card extension unit
*1
External I/O unit
Sound output unit
Fingerprint unit
GT15-CFEX-C08SET
GT15-DIO,
GT15-SOUT
GT15-80FPA
GT15-DIOR
*1 GT15-CFEX + GT15-CFEXIF + GT15-C08CF set.
Description
GT15-ABUS2,
GT15-75ABUS2L
A - 16
Option
Abbreviations and generic terms
Memory card CF card
Memory card adaptor
Option function board
Battery
Protective Sheet
Protective cover for oil
USB environmental protection cover
Stand
Attachment
Backlight
Multi-color display board
Connector conversion box
Emergency stop sw guard cover
Memory loader
Memory board
GT05-MEM-16MC,
GT05-MEM-256MC
GT05-MEM-ADPC
For GT16
GT16-90PSCB,
GT16-80PSCB,
GT16-70PSCB,
GT16-60PSCB,
Description
GT05-MEM-32MC, GT05-MEM-64MC, GT05-MEM-128MC,
GT05-MEM-512MC, GT05-MEM-1GC,
GT16-MESB, GT15-FNB, GT15-QFNB,
GT15-QFNB32M, GT15-QFNB48M, GT15-MESB48M,
GT15-BAT, GT11-50BAT
GT05-MEM-2GC
GT15-QFNB16M,
GT11-50FNB
GT16-90PSGB, GT16-90PSCW, GT16-90PSGW,
GT16-80PSGB, GT16-80PSCW, GT16-80PSGW,
GT16-70PSGB, GT16-70PSCW, GT16-70PSGW,
GT16-60PSGB, GT16-60PSCW, GT16-60PSGW
For GT15
For GT11
For GT10
GT15-90PSCB,
GT15-80PSCB,
GT15-70PSCB,
GT15-60PSCB,
GT15-50PSCB,
GT11-50PSCB,
GT11H-50PSC
GT10-50PSCB,
GT10-40PSCB,
GT10-30PSCB,
GT10-20PSCB,
GT15-90PSGB, GT15-90PSCW, GT15-90PSGW,
GT15-80PSGB, GT15-80PSCW, GT15-80PSGW,
GT15-70PSGB, GT15-70PSCW, GT15-70PSGW,
GT15-60PSGB, GT15-60PSCW, GT15-60PSGW,
GT15-50PSGB, GT15-50PSCW, GT15-50PSGW
GT11-50PSGB, GT11-50PSCW, GT11-50PSGW,
GT10-50PSGB,
GT10-40PSGB,
GT10-30PSGB,
GT10-20PSGB,
GT10-50PSCW,
GT10-40PSCW,
GT10-30PSCW,
GT10-20PSCW,
GT10-50PSGW,
GT10-40PSGW,
GT10-30PSGW,
GT10-20PSGW
GT05-50PCO
GT16-UCOV,
GT05-50STAND
GT15-UCOV, GT11-50UCOV
GT16-90XLTT,
GT16-70SLTT,
GT15-70SLTT,
60VLTN
GT15-XHNB,
GT11H-CNB-37S
GT11H-50ESCOV
GT10-LDR
GT10-50FMB
GT16-80SLTT,
GT16-70VLTT,
GT15-70VLTT,
GT15-VHNB
GT15-90XLTT,
GT16-60SLTT,
GT15-70VLTN,
GT15-80SLTT,
GT16-60VLTT,
GT15-60VLTT,GT15-
A - 17
Software
Abbreviations and generic terms
GT Works3
GT Designer3
GT Simulator3
GT Works2 Version
GT Designer2 Version
GT Designer2
GT Converter2
GT Designer2 Classic
GT Simulator2
GT SoftGOT1000
GT SoftGOT2
GX Developer
GX Simulator2
GX Simulator
Document Converter
PX Developer
MT Works2
MT Developer
MR Configurator
FR Configurator
FX Configurator-FP
FX3U-ENET-L Configuration tool
RT ToolBox2
Description
Abbreviation of the SW DNC-GTWK3-E and SW DNC-GTWK3-EA
Abbreviation of screen drawing software GT Designer3 for GOT1000 series
Abbreviation of screen simulator GT Simulator3 for GOT1000/GOT900 series
SW D5C-GTWK2-E, SW D5C-GTWK2-EV
SW D5C-GTD2-E, SW D5C-GTD2-EV
Abbreviation of screen drawing software GT Designer2 for GOT1000/GOT900 series
Abbreviation of data conversion software GT Converter2 for GOT1000/GOT900 series
Abbreviation of screen drawing software GT Designer2 Classic for GOT900 series
Abbreviation of screen simulator GT Simulator 2 for GOT1000 / GOT900 series
Abbreviation of monitoring software GT SoftGOT1000
Abbreviation of monitoring software GT SoftGOT2
Abbreviation of SW D5C-GPPW-E(-EV)/SW D5F-GPPW-E type software package
Abbreviation of GX Works2 with the simulation function
Abbreviation of SW D5C-LLT-E(-EV) type ladder logic test tool function software packages
(SW5D5C-LLT (-EV) or later versions)
Abbreviation of document data conversion software Document Converter for GOT1000 series
Abbreviation of SW D5C-FBDQ-E type FBD software package for process control
Abbreviation of motion controller engineering environment MELSOFT MT Works2 (SW DNC-
MTW2-E)
Abbreviation of SW RNC-GSV type general start-up support software for motion controller Q series
Abbreviation of MRZJW -SETUP type servo set up software
Abbreviation of Inverter Setup Software (FR-SW -SETUP-WE)
Abbreviation of parameter setting, monitoring, and testing software packages for FX3U-20SSC-
H (SW D5C-FXSSC-E)
Abbreviation of FX3U-ENET-L type Ethernet module setting software (SW1D5-FXENETL-E)
Abbreviation of robot program creation software (3D-11C-WINE)
License key (for GT SoftGOT1000)
Abbreviations and generic terms
License
License key (for GT SoftGOT2)
Abbreviations and generic terms
License key
License key FD
GT15-SGTKEY-U, GT15-SGTKEY-P
Description
Description
A9GTSOFT-LKEY-P (For DOS/V PC)
SW5D5F-SGLKEY-J (For PC CPU module)
A - 18
Others
Abbreviations and generic terms
OMRON PLC
KEYENCE PLC
KOYO EI PLC
SHARP PLC
JTEKT PLC
TOSHIBA PLC
TOSHIBA MACHINE PLC
HITACHI IES PLC
HITACHI PLC
FUJI FA PLC
PANASONIC PLC
YASKAWA PLC
YOKOGAWA PLC
ALLEN-BRADLEY PLC
GE FANUC PLC
LS IS PLC
SCHNEIDER PLC
SIEMENS PLC
Temperature controller
OMRON temperature controller
SHINKO indicating controller
CHINO controller
FUJI SYS temperature controller
YAMATAKE temperature controller
YOKOGAWA temperature controller
RKC temperature controller
PC CPU module
GOT (server)
GOT (client)
Description
Abbreviation of PLC manufactured by OMRON Corporation
Abbreviation of PLC manufactured by KEYENCE CORPORATION
Abbreviation of PLC manufactured by KOYO ELECTRONICS INDUSTRIES CO., LTD.
Abbreviation of PLC manufactured by Sharp Manufacturing Systems Corporation
Abbreviation of PLC manufactured by JTEKT Corporation
Abbreviation of PLC manufactured by TOSHIBA CORPORATION
Abbreviation of PLC manufactured by TOSHIBA MACHINE CO., LTD.
Abbreviation of PLC manufactured by Hitachi Industrial Equipment Systems Co., Ltd.
Abbreviation of PLC manufactured by Hitachi, Ltd.
Abbreviation of PLC manufactured by Fuji Electric FA Components & Systems Co., Ltd.
Abbreviation of PLC manufactured by Panasonic Electric Works Co., Ltd.
Abbreviation of PLC manufactured by YASKAWA Electric Corporation
Abbreviation of PLC manufactured by Yokogawa Electric Corporation
Abbreviation of Allen-Bradley PLC manufactured by Rockwell Automation, Inc.
Abbreviation of PLC manufactured by GE Fanuc Automation Corporation
Abbreviation of PLC manufactured by LS Industrial Systems Co., Ltd.
Abbreviation of PLC manufactured by Schneider Electric SA
Abbreviation of PLC manufactured by Siemens AG
Abbreviation of temperature controller manufactured by OMRON Corporation
Abbreviation of temperature controller manufactured by Shinko Technos Co., Ltd.
Abbreviation of temperature controller manufactured by CHINO CORPORATION
Abbreviation of temperature controller manufactured by Fuji Electric Systems Co., Ltd.
Abbreviation of temperature controller manufactured by Yamatake Corporation
Abbreviation of temperature controller manufactured by Yokogawa Electric Corporation
Abbreviation of temperature controller manufactured by RKC INSTRUMENT INC.
Abbreviation of PC CPU Unit manufactured by CONTEC CO., LTD
Abbreviation of GOTs that use the server function
Abbreviation of GOTs that use the client function
Windows font
Intelligent function module
Abbreviation of TrueType font and OpenType font available for Windows
(Differs from the True Type fonts settable with GT Designer2)
Indicates the modules other than the PLC CPU, power supply module and I/O module that are mounted to the base unit.
MODBUS
MODBUS
/RTU
/TCP
Generic term for protocols designed to use MODBUS protocol messagages on a serial communication.
Generic term for the protocol designed to use MODBUS protocol messages on a TCP/IP network.
A - 19
HOW TO READ THIS MANUAL
1
Functions
This manual describes functions available for the GT Designer2 Version2.98C, GT Designer3
Version1.01B.
For the added functions by the product version upgrade, refer to the list of functions added by GT
Designer2 version upgrade in Appendices.
2
Symbols
Following symbols are used in this manual.
13.3.3 Memory check operation
Carries out write/read check of memory.
When drive is not displayed
When the drive (memory) to check is not displayed, confirm the mounting procedure or memory type with reference to the following.
• CF card inserting/removing method Section 7.1 CF Card
When no faults are found in mounting, etc, a memory failure may be arosen.
Replace the CF card or Flash memory.
For details of Flash memory, contact your nearest sales office or FA Center.
The following example explains about Memory Check using Flash memory.
For the CF card memory check, install the CF card before carrying out the same key operations as built-in flash memory.
1
Select [Flash Memory] in the Memory check setting screen, and touch the
Check
button.
If select the
OK
button, the numeric keyboard window is displayed.
If select the Cancel to the initial menu.
button, the screen returns
2
3
4
Touch
5 9 2 0
and then Enter .
(The password is fixed to 5920.)
Touching
Enter
executes read/write check for the flash memory.
Remark
Refers to the information required.
Refers to the supplementary explanations for reference.
Indicates the items in which the detailed explanation is described (manual, chapter, section, item of the manual).
. . . .
Indicates the operation steps.
Menu and items are differentiated with parentheses.
[ ]
: refers to the menu of GOT utility.
: refers to the button in the dialog
box of GOT utility.
13 - 4
13.3 Memory Check
13.3.3 Memory check operation
A - 20
1. OVERVIEW
1
About GOT
A GOT is installed on the panel surface of a control panel or operating panel and connects to the PLC within the control panel. The GOT carries out switch operation, lamp display, data display, message display, etc.
PLC
Connector for program
For the display screen, two kinds of screens are available : user screen and utility screen.
(1) User screen
The user screen is a screen drawn by drawing software.
GOT
The objects "Touch switch", "Lamp display", "Comment display", and "Numeric display" can be arditrarily arranged on the display.
A "horizontal format" or "vertical format" may be selected for displaying a user’s project.
Moreover, multiple screens created within drawing software can be individually selected or overlapped for the display.
For details, refer to the following.
GT Designer2 Version Basic Operation/Data Transfer Manual
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual
(2) Utility Screen
The utility screen is a factory drawn horizontal screen that cannot be edited.
The utility screen has options for "Contrast ", "Buzzer volume ", etc, and the format is horizontal only.
For details, refer to the following.
2
3
4
5
6
1
7
8
1 - 1
2
About Manual
The following manuals related to GOT 1000 series are available. Refer to each manual in accordance with the intended use.
(1) Installation of the software programs Drawing Data transfer
For operations from creating project data to transferring data to GOT, refer to the following manuals.
Purpose
Installing product on PC
GT Designer2 Version
Basic Operation/Data Transfer
Manual
*1
GT Designer3 Version
Screen Design Manual
(Fundamentals)
*1
GT Designer2 Version
Screen Design Manual
*1
GT Designer3 Version
Screen Design Manual (Functions)
*1
Detailed
Creating projects
Detailed
Creating screens
Detailed
Drawing figures
Detailed
Making Common Settings
Overview
Placing/Setting objects
Overview
Transferring data to GOT
Detailed
*1 Stored in the GT Works 2/GT Designer2/GT Works 3/GT Designer3 in PDF format.
Detailed
Detailed
1 - 2
(2) Installing a GOT connection to a PLC
For the operations from installing a GOT to communicating with a PLC CPU, refer to the following manuals.
1
Purpose
(Included)
GT15 General
Description
GT 11 General
Description
GT 10 General
Description
GT15 User's Manual
GT11 User's Manual
GT10 User's Manual
GOT1000 Series
Connection Manual
*1
Confirming part names and specifications of the GOT
Confirming the GOT installation method
Confirming the mounting method for communication units or option devices
Confirming the PLC connection method
Overview
Overview
Detailed
Detailed
Detailed
Overview
Detailed
Confirming the utility operation method
Detailed
Confirming error codes (system alarm) displayed on the GOT
Detailed
*1 Stored in the GT Works2/GT Designer2/GT Works 3/GT Designer3 in PDF format.
(3) Other manuals
The following manuals are also available.
The following manuals are stored in the GT Works2/GT Designer2/GT Works3/GT Designer3 in
PDF format.
(a) GOT1000 Series Gateway Functions Manual
Describes how to use the gateway function.
(b) GT Simulator 2 Version Operation Manual
Describes how to simulate the created project data with GT Simulator2.
(c) GT Converter2 Version Operating Manual
Describes how to use the GT Converter2.
2
3
4
5
6
7
8
1 - 3
1.1 Features
(1) Improved monitoring performance and connectivity to FA devices
• Multiple languages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts
• For GT1020 and GT1030, 3 backlight colors (green, red, orange or white, red, pink) are available for status displays
• For GT104 and GT105 , two types of display modes are available: 256 colors display and monochrome
In the monochrome display, 16 scales are used to improve the display
• Improved layout design flexibility with the analog touch panel on the GT1020
• High speed monitoring through high speed communication at maximum of 115.2kbps
• High speed display and high speed touch switch response
(2) More efficient GOT operations including screen design, startup, adjustment, management and maintenance works
• Recipe function, Device monitor function and FX list editor function (for GT104 , GT105 only) and Device monitor (for GT105 only)
• Factory-installed OS on the GOT
• For GT1020, GT1030 and GT104 , LED-type backlight is adopted (no replacement required)
• High speed data transfer of project data, OS and others using the USB interface (for GT104 ,
GT105 only)
(3) Enhanced support of FA setup tools
• Transferring or monitoring the sequence programs using the personal computer connected to
GOT, during connection to A, Q, QnA, or FX series PLC CPU (Transparent function)
• Allows the connection of multiple GOT units via the serial interface when connected to the CPU on the A, Q, QnA, or FX series of PLC
1 - 4
1.1 Features
1.2 Rough Pre-operation Procedure
The outline procedure before operating GOT is shown.
Start
Install GT Designer2 or GT Designer3 in the PC.
Create project data.
Refer to GT Designer2 Version
Basic Operation/Data Transfer Manual.
Refer to GT Designer3 Version
Screen Design Manual (Fundamentals)
Refer to GT Designer2 Version
Screen Design Manual.
Refer to GT Designer3 Version
Screen Design Manual (Functions)
Refer to Chapter 7 WIRING.
Wire for the GOT power supply.
Connect GOT and PC with a RS-232/USB conversion adaptor or RS-232 cable.
Refer to Chapter 8 OPTION.
1) Install a communication driver on the GOT that
is compatible with the controller.
(The communication driver for the FX series is
factory-installed.)
2) Install the project data that were created with
GT Designer2 or GT Designer3 on the GOT.
Refer to GT Designer2 Version
Basic Operation/Data Transfer Manual.
Refer to GT Designer3 Version
Screen Design Manual (Fundamentals)
Check the communication settings.
Connect the GOT and the destination connector.
Turn on the GOT power and the system of the connection destination.
Start the monitor. (Display each screen.)
End
Refer to GOT1000 Series Connection Manual.
1.2 Rough Pre-operation Procedure
1 - 5
7
8
5
6
3
4
1
2
2. SYSTEM CONFIGURATION
2.1 Overall Configuration
The overall configuration of GOT is as follows.
For the connection methods applicable to GOT1000 series and cable, refer to the following.
GOT1000 Series Connection Manual
(For GT1020, GT1030)
Protective sheet
GT10-LDR
Memory Loader
USB connecting cable
(supplied)
Serial multi-drop connection unit
MITSUBISHI
GOT
1000
GOT
RS-232 cable
(designed exclusively for use with the GOT)
Personal computer
RS-232
Connect to the RS-232 connector of the RS-
232/USB conversion adaptor
RS-232/USB conversion adaptor
Commercially available
USB cable
(designed exclusively
for use with the GOT)
Bar code reader
• GT10 cannot be connected to printers.
Commercially available
2 - 1
2.1 Overall Configuration
(For GT104 , GT105 )
Protective cover for oil Memory board
Personal computer
Commercially available
Protective sheet
1
2
Debug stand
MITSUBISHI
GOT
1000
GOT
3
Bar code reader
4
Connector conversion adapter
Commercially available
Serial multi-drop connection unit
5
6
• Debug stand and protective cover for oil are only available for GT105 .
• GT10 cannot be connected to printers.
7
8
2.1 Overall Configuration
2 - 2
2.2 Component List
(1) Explanation of the GOT model name
G T 1 0 2 0
Interface type
*2 for communication with PLC
2
Blank
: RS-232
: RS-422
Backlight type
*2
W
Blank
: white / red / pink
: green / red / orange
Power type
Panel color type
A : 100 to 240VAC
D : 24VDC
L : 5VDC
B : Black
W : White
Display device type
T : TFT color (High intensity, wide angle view)
N : TFT color
S : STN color
L : STN monochrome (black and white)
B : STN monochrome (blue and white)
Resolution
X
S
V
Q
: 1024 768 (XGA)
: 800 600 (SVGA)
: 640 480 (VGA)
: 320 240 (QVGA)
Blank : less than 320 240
Display color type
5 : 256 colors supported / 65536 colors supported
*1
2 : 16 colors
0 : Monochrome (black and white, blue and white)
Screen size type
9 : 15.0"
8 : 12.1"
7 : 10.4"
6 : 8.4"
5 : 5.7"
4 : 4.7"
3 : 4.5"
2 : 3.7"
GOT 1000 series GT15/GT11/GT10
*1: For GT15 that can display 65536 colors, refer to following.
GT15 User's Manual
*2: Dedicated for GT1020, GT1030
2 - 3
2.2 Component List
(2) Explanation of the option model name
G T
90 : Dedicated for 15.0"
80 : Dedicated for 12.1"
75 : Common for 10.4", 8.4"
70 : Dedicated for 10.4"
60 : Dedicated for 8.4"
50 : Dedicated for 5.7"
40 : Dedicated for 4.7"
30 : Dedicated for 4.5"
20 : Dedicated for 3.7"
15 : For GT15
*1
11 : For GT11
*1
09 :
05 : For GT15/GT11/GT10
*1
01 :
10 : For GT10
*1
*1: There are optional components common for GT15, GT11 and GT10.
2.2 Component List
2 - 4
7
8
5
6
3
4
1
2
2.2.1
GOT (GT10)
Product name
GOT
Model name
GT1020-LBD/LWD
GT1020-LBD2/LWD2
GT1020-LBL/LWL
GT1020-LBDW/LWDW
GT1020-LBDW2/LWDW2
GT1020-LBLW/LWLW
GT1030-LBD/LWD
GT1030-LBD2/LWD2
GT1030-LBL/LWL
GT1030-LBDW/LWDW
GT1030-LBDW2/LWDW2
GT1030-LBLW/LWLW
GT1045-QSBD
GT1040-QBBD
GT1055-QSBD
GT1050-QBBD
Specifications
3.7" [160 64 dots], STN monochrome (black and white) liquid crystal, 3 colors (green/ red/orange) LED backlight, 24VDC,
PLC connection interface: RS-422
3.7" [160 64 dots], STN monochrome (black and white) liquid crystal, 3 colors (green/ red/orange) LED backlight, 24VDC,
PLC connection interface: RS-232
3.7" [160 64 dots], STN monochrome (black and white) liquid crystal, 3 colors (green/ red/orange) LED backlight, 5VDC,
PLC connection interface: RS-422
3.7" [160 64 dots], STN monochrome (black and white) liquid crystal, 3 colors (white/ red/pink) LED backlight, 24VDC,
PLC connection interface: RS-422
3.7" [160 64 dots], STN monochrome (black and white) liquid crystal, 3 colors (white/ red/pink) LED backlight, 24VDC,
PLC connection interface: RS-232
3.7" [160 64 dots], STN monochrome (black and white) liquid crystal, 3 colors (white/ red/pink) LED backlight, 5VDC,
PLC connection interface: RS-422
4.5" [288 96 dots], STN monochrome (black and white) liquid crystal, 3 colors
(green/red/orange) LED backlight, built-in battery
24VDC, PLC connection interface: RS-422
4.5" [288 96 dots], STN monochrome (black and white) liquid crystal, 3 colors
(green/red/orange) LED backlight, built-in battery
24VDC, PLC connection interface: RS-232
4.5" [288 96 dots], STN monochrome (black and white) liquid crystal, 3 colors
(green/red/orange) LED backlight, built-in battery
5VDC, PLC connection interface: RS-422
4.5" [288 96 dots], STN monochrome (black and white) liquid crystal, 3 colors (white/ red/pink) LED backlight, built-in battery
24VDC, PLC connection interface: RS-422
4.5" [288 96 dots], STN monochrome (black and white) liquid crystal, 3 colors (white/ red/pink) LED backlight, built-in battery
24VDC, PLC connection interface: RS-232
4.5" [288 96 dots], STN monochrome (black and white) liquid crystal, 3 colors
(white/red/pink) LED backlight, built-in battery
5VDC, PLC connection interface: RS-422
4.7" [320 240 dots], STN color liquid crystal, 256 colors, built-in battery
24VDC, PLC connection interface: RS-422, RS-232
4.7" [320 240 dots], STN monochrome liquid crystal, monochrome (blue and white), 16 scales, built-in battery
24VDC, PLC connection interface: RS-422, RS-232
5.7" [320 240 dots], STN color liquid crystal, 256 colors, built-in battery
24VDC, PLC connection interface: RS-422, RS-232
5.7" [320 240 dots], STN monochrome liquid crystal, monochrome (blue and white), 16 scales, built-in battery
24VDC, PLC connection interface: RS-422, RS-232
2 - 5
2.2 Component List
2.2.1 GOT (GT10)
2.2.2
Option (Optional components for GT10)
PLC connection cable (Sold separately)
Product name Model name
GT01-C10R4-8P
Cable length
1m
Contents
GT01-C30R4-8P
GT01-C100R4-8P
GT01-C200R4-8P
3m
10m
20m
For connecting FXCPU (MINI DIN 8 pins connector) and GOT,
For connecting FXCPU expansion board (MINI
DIN 8 pins connector) and GOT(For GT104 ,
GT105 )
FXCPU direct connection cable,
FX expansion board connection cable
GT01-C300R4-8P
GT10-C10R4-8P
GT10-C30R4-8P
30m
1m
3m
GT10-C100R4-8P
GT10-C200R4-8P
10m
20m
For connecting FXCPU (MINI DIN 8 pins connector) and GOT,
For connecting FXCPU expansion board (MINI
DIN 8 pins connector) and GOT(For GT1030,
GT1020)
GT10-C300R4-8P 30m
RS-422
Cable
GT10-C10R4-8PL
*1
1m
GT01-C30R4-25P
GT01-C100R4-25P
GT01-C200R4-25P
QnA/A/FXCPU direct connection cable, computer link connection cable
GT01-C300R4-25P
GT10-C30R4-25P
GT10-C100R4-25P
3m
10m
20m
30m
3m
For connecting QnA/A/FXCPU (D-sub 25 pins connector) and GOT,
For connecting serial communication unit
(AJ71QC24(N)-R4) and GOT(For GT104 ,
GT105 )
GT10-C200R4-25P
10m
20m
For connecting QnA/A/FXCPU (D-sub 25 pins connector) and GOT,
For connecting serial communication unit
(AJ71QC24(N)-R4) and GOT(For GT1030,
GT1020)
GT10-C300R4-25P 30m
Computer link connection cable
GT09-C30R4-6C
GT09-C100R4-6C
GT09-C200R4-6C
3m
10m
20m
For connecting computer link unit/serial communication unit and GOT(For GT104 ,
GT105 )
GT09-C300R4-6C 30m
*1: GT10-C10R4-8PL cannot be used for FX
0
, FX
0S
, FX
0N
, FX
1
, FX
2
, FX
2C
, FX
1NC
, FX
2NC
, FX
3UC
(D/DSS), or
FX
3G
PLC.
2.2 Component List
2.2.2 Option (Optional components for GT10)
2 - 6
1
2
3
4
5
6
7
8
2 - 7
Product name
RS-232
Cable
QCPU direct connection cable
FX expansion board connection cable,
FX special adaptor connection cable
FX special adaptor connection
Computer link connection cable
Model name
GT01-C30R2-6P
GT10-C30R2-6P
GT01-C30R2-9S
GT01-C30R2-25P
GT09-C30R2-9P
Cable length
3m
3m
3m
3m
3m
GT09-C30R2-25P 3m
*2: Connector shape on the cable is shown in ( ).
Contents
For connecting QCPU (MINI DIN 6 pins) and
GOT(For GT104 , GT105 )
For connecting QCPU (MINI DIN 6 pins) and
GOT(For GT1030, GT1020)
For connecting FXCPU expansion board (D-sub
9pins connector
*2
) and GOT(For GT104 ,
GT105 )
For connecting FXCPU special adaptor (D-sub 9 pins connector
*2
) and GOT(For GT104 ,
GT105 )
For connecting FXCPU special adaptor (D-sub
25 pins connector
*2
) and GOT(For GT104 ,
GT105 )
For connecting computer link unit/serial communication unit and GOT(For GT104 ,
GT105 )
Connection cables for OMRON PLCs (For GT104 , GT105 ) (Sold separately)
Product name
Model name Cable length Description
RS-422 cable
GT09-C30R40101-9P
GT09-C100R40101-9P
GT09-C200R40101-9P
GT09-C300R40101-9P
GT09-C30R40102-9P
GT09-C100R40102-9P
GT09-C200R40102-9P
GT09-C300R40102-9P
3m
10m
20m
30m
3m
10m
20m
30m
For connecting GOT to OMRON PLC, serial communication module, serial communication board
For connecting GOT to OMRON rack type host link unit, communication board
RS-232 cable
GT09-C30R20101-9P
GT09-C30R20102-25S
GT09-C30R20103-25P
3m
3m
3m
For connecting GOT to OMRON PLC, serial communication module, communication board, serial communication board
For connecting GOT to OMRON connection cable
For connecting GOT to OMRON rack type host link unit
Connection cables for KEYENCE PLCs (For GT104 , GT105 ) (Sold separately)
Product name
Model name Cable length Description
RS-422 cable
GT09-C30R41101-5T
GT09-C100R41101-5T
GT09-C200R41101-5T
GT09-C300R41101-5T
3m
10m
20m
30m
For connecting GOT to KEYENCE multi-communication unit
2.2 Component List
2.2.2 Option (Optional components for GT10)
Product name
Model name
RS-232 cable
GT09-C30R21101-6P
GT09-C30R21102-9S
GT09-C30R21103-3T
Cable length
3m
3m
3m
Description
For connecting GOT to KEYENCE PLC
For connecting GOT to KEYENCE multi-communication unit
For connecting GOT to KEYENCE multi-communication unit
Connection cables for MATSUSHITA PLCs (For GT104 , GT105 ) (Sold separately)
Product name
Model name Cable length Description
GT09-C30R20901-25P 3m
For connecting GOT to MATSUSHITA RS422/232C conversion adaptor
RS-232 cable
GT09-C30R20902-9P
GT09-C30R20903-9P
GT09-C30R20904-3C
3m
3m
3m
For connecting GOT to the tool port or RS232C port of
MATSUSHITA PLC, computer communication unit
For connecting GOT to the RS232C port of MATSUSHITA PLC
For connecting GOT to the RS232C port of MATSUSHITA PLC
Connection cables for YASKAWA PLCs (For GT104 , GT105 ) (Sold separately)
Product name
Model name Cable length Description
GT09-C30R40202-14P 3m
RS-422 cable
RS-232 cable
GT09-C100R40202-14P
GT09-C200R40202-14P
GT09-C300R40202-14P
GT09-C30R20201-9P
GT09-C30R20204-14P
GT09-C30R20205-25P
10m
20m
30m
3m
3m
3m
For connecting GOT to YASKAWA PLC
For connecting GOT to YASKAWA PLC
For connecting GOT to YASKAWA MEMOBUS module
Connection cables for Allen-Bradley PLCs (For GT104 , GT105 ) (Sold separately)
Product name
RS-232 cable
Model name
GT09-C30R20701-9S
Cable length
3m
Description
For connecting GOT to Allen-Bradley PLC
1
2
3
4
5
6
7
8
2.2 Component List
2.2.2 Option (Optional components for GT10)
2 - 8
Protective sheet (Sold separately)
Product name
Protective sheet
Model name
GT10-20PSGB
GT10-20PSCB
GT10-20PSGW
GT10-20PSCW
GT10-30PSGB
GT10-30PSCB
GT10-30PSGW
GT10-30PSCW
GT10-40PSGB
GT10-40PSCB
GT10-40PSGW
GT10-40PSCW
GT10-50PSGB
GT10-50PSCB
GT10-50PSGW
GT10-50PSCW
3.7
"
protective sheet
(For GT1020)
4.5
"
protective sheet
(For GT1030)
4.7" protective sheet
(For GT104 )
5.7" protective sheet
(For GT105 )
Contents
Display section antiglare (Frame: transparent) 5 sheets
Display section clear (Frame: transparent) 5 sheets
Display section antiglare (Frame: white), With a logo 5 sheets
Display section clear (Frame: white), With a logo 5 sheets
Display section antiglare (Frame: transparent) 5 sheets
Display section clear (Frame: transparent) 5 sheets
Display section antiglare (Frame: white), With a logo 5 sheets
Display section clear (Frame: white), With a logo 5 sheets
Display section antiglare (Frame: transparent) 5 sheets
Display section clear (Frame: transparent) 5 sheets
Display section antiglare (Frame: white), With a logo 5 sheets
Display section clear (Frame: white), With a logo 5 sheets
Display section antiglare (Frame: transparent) 5 sheets
Display section clear (Frame: transparent) 5 sheets
Display section antiglare (Frame: white), With a logo 5 sheets
Display section clear (Frame: white), With a logo 5 sheets
Drawing software (Sold separately)
Product name
GT Designer2
GT Designer3
Model name
SW D5C-GTD2-E
( indicates the version)
*1
Drawing software for GOT1000/GOT900 series
SW DNC-GTD3-E
( indicates the version)
Contents
Drawing software for GOT1000 series
*1: The is assigned with an integer 2 or more.
Stand (Sold separately) (For GT105 )
Product name
Stand
Model name
GT05-50STAND
Contents
Stand for 5.7" (For GOT1000 Series)
Protective cover for oil (Sold separately) (For GT105 )
Product name Model name
Protective cover for oil GT05-50PCO 5.7" protective cover for oil
Contents
2 - 9
2.2 Component List
2.2.2 Option (Optional components for GT10)
PC connection cable (Sold separately)
Product name
For connection to the RS-232 port on the PC
Data transfer cable
For connection to the USB port on the PC
RS-232/USB conversion adaptor for data transfer
Data transfer cable
Model name
GT01-C30R2-6P
GT01-C30R2-9S
GT10-
RS2TUSB-5S
GT09-C30USB-
5P
*3
Cable length
3m
3m
Contents
For connecting PC (drawing software) (D-sub
9 pins: female
*2
) and GOT(For GT1020,
GT1030)
For connecting PC (drawing software) (D-sub
9 pins: female
*2
) and GOT(For GT104 ,
GT105 )
−
3m
RS-232/USB conversion adaptor for data transfer (RS-232/USB conversion adaptor and PC are connected with a GT09-C30USB-
5P cable.)
For connecting PC (drawing software) (USB) and RS-232/USB conversion adaptor,
GOT(For GT104 , GT105 )
*2: Connector shape on the cable is shown in ( ).
*3: GT09-C30USB-5P is a product of Mitsubishi Electric System Service.
Cable for bar code connections (Sold separately)
Product name
Cable for bar code connections
Model name
GT10-C02H-6PT9P
Cable length
0.2m
Contents
For connecting GOT and bar code reader
Cable for multiple GOT connections (Sold separately)
Product name Model name Cable length
Cable for multiple
GOT connections
GT10-C30R2-6P
GT01-C30R2-9S
3m
3m
Contents
For connecting GOT(GT1020, GT1030) interface for connection to PC (RS-232) and GOT(GT1020, GT1030) interface for connection to PLC (RS-232)
*4
For connecting GOT(GT104 , GT105 ) RS-232 interface and GOT(GT104 , GT105 ) RS-232 interface
*4: When multiple GT10 units are connected, use a GT1020-LBD2/LWD2 or GT1030-LBD2/LWD2 for the second
GOT unit.
Battery (Sold separately)
Product name
Battery
*5
Model name
GT11-50BAT
Contents
For storing clock data, alarm history and recipe data
*5 At GOT purchase, it is installed in the main unit. (For GT1030, GT104 , GT105 )
1
2
3
4
5
6
7
8
2.2 Component List
2.2.2 Option (Optional components for GT10)
2 - 10
Bar code reader (Sold separately)
Product name
Bar code reader
Model name
-
Contents
Commercially-available bar code reader
*6
*6: Some models with the operations checked by our company are usable.
For the operation-checked models, refer to "List of valid devices applicable for GOT1000 series" separately available (T10-0039).
The Technical News above is available as a reference at the Information site for Mitsubishi industrial automation products MELFANSweb home page.
(MELFANSweb home page: http://wwwf2.mitsubishielectric.co.jp/melfansweb/english/index_e.htm)
Memory board (Sold separately) (For GT104 , GT105 )
Product name
Memory board
Model name
GT10-50FMB
Contents
For copying project data or the OS
Serial multi-drop connection unit (Sold separately)
Product name
Serial multi-drop connection unit
Model name
GT01-RS4-M For GOT multi-drop connection
Contents
Connector conversion adapter (Sold separately) (For GT104 , GT105 )
Product name
Connector conversion adapter
Model name
GT10-9PT5S For GOT multi-drop connection
Contents
2 - 11
2.2 Component List
2.2.2 Option (Optional components for GT10)
3. SPECIFICATIONS
3.1 General Specifications
2
Operating ambient temperature
Item
-20 to 60
Specifications
Display section 0 to 50
Other than display section
0 to 55 (when horizontally installed), 0 to 50 (when vertically installed)
Storage ambient temperature
Operating ambient humidity
*1
Storage ambient humidity
*1
10 to 90% RH, non-condensing
10 to 90% RH, non-condensing
Vibrationresistance
Shock resistance
Operating atmosphere
Frequency Acceleration
Halfamplitude
3.5mm
Sweep Count
Conforms to
JIS B3502 and
IEC61131-2
Under intermittent vibration
Under continuous vibration
5 to 9Hz
9 to 150Hz
5 to 9Hz
9 to 150Hz
-
9.8m/s
-
4.9m/s
2
2
1.75mm
-
10 times each in X, Y and Z directions
Conforms to JIS B3502, IEC 61131-2 (147 m/s
2
, 11 ms, Sine half-wave pulse, 3 times each in the X, Y, and Z directions)
Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electroconductive dust particles and must be no direct sunlight. (Same as for saving)
Operating altitude
*2
Installation location
Overvoltage category
*3
Pollution degree
*4
Cooling method
2000 m (6562 ft) max.
Inside control panel
II or less
2 or less
Self-cooling
Grounding
*5
Class D grounding (100 or less),
To be connected to the panel when grounding is not possible
*1 : The wet bulb temperature is 39 or less.
*2 : Do not use or store the GOT under pressures higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction.
When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result, the touch panel may be difficult to press, and the sheet may be peeled off.
*3 : This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.
*4 : This index indicates the degree to which conductive pollution is generated in the environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.
*5: Except 5V power supply type.
3
4
5
6
7
8
1
3.1 General Specifications
3 - 1
3.2 Performance Specifications
• GT1020
Display section *1
Backlight
Item
Type
Screen size
Resolution
GT1020-LBD/LWD
Specifications
GT1020-LBD2/LWD2
STN monochrome (white/black) liquid crystal
3.7"
GT1020-LBL/LWL
160 64 dots (Horizontal format)
Display size
W86.4(3.4) H34.5(1.35) [mm](inch) (Horizontal format)
Display character
Display color
16-dot standard font: 20 characters
Monochrome (white/black)
4 lines (Horizontal format)
Display angle Left/Right: 30 degrees, Top: 20 degrees, Bottom: 30 degrees (Horizontal format)
Contrast adjustment 16-level adjustment
Intensity of LCD only
200 [cd/m
2
] (in green)
Life
Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25 )
LED with 3 available colors (green, red, orange) (no replacement required),
Backlight status (colors, ON/BLINK/OFF) control, Adjustable screensaver activation time
Setting the system information
*2
enables PLC to control the backlight status.
Number of touch keys Maximum 50 keys/screen (Analog resistive film touch panel)
Touch panel
Memory
Built-in interface
Key size
Minimum 2 2 dots (per key)
Simultaneous pressing of two (or more) areas
(2-point press)
Life
User memory *3
Not supported
(Simultaneous pressing of two or more areas on the screen may activate the switch between those areas.)
1 million times or more (operating force 0.98N max.)
Flash memory (Internal), for storing project data (512 Kbytes or less), OS, Alarm history and
Recipe data
Life (Number of write times)
100,000 times
• RS-422 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
(Hardware version A to D)
PLC communication
• RS-422/485 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
Terminating resistor
*4
:
Open/110 /330
(Switched by terminating resistor selector switch) (At factory shipment: 330 )
(Hardware version E or later)
RS-232 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
RS-422 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
PC communication
RS-232 1ch
Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape
Application
: MINI DIN 6 pins (Female)
: PC communication (Project data upload/download, OS installation, transparent function)
Buzzer output (a buzzer that sounds when touch keys are pressed)
Single tone (LONG/SHORT/OFF adjustable)
Environmental protective structure *5 Equivalent to IP67 (JEM1030) (front section) (Horizontal format)
External dimensions
W113(4.44) H74(2.91) D27(1.06) [mm](inch) (Horizontal format)
Panel cutting dimensions W105(4.13) H66(2.59) [mm](inch) (Horizontal format)
3 - 2
3.2 Performance Specifications
Item
GT1020-LBD/LWD
Specifications
GT1020-LBD2/LWD2 GT1020-LBL/LWL
Weight 0.2kg (Excluding mounting fixtures)
0.18kg (Excluding mounting fixtures)
Compatible software package GT Designer2 Version2.43V or later/GT Designer3 Version1.01B or later
*1: Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
Flickers may be observed depending on the display color. Please note that these dots appear due to its characteristic and are not caused by product defect.
Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment. However, please note that these phenomena appear due to its characteristic and are not caused by product defect.
There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note that there is an individual difference between them.
A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.
When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.
Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.
When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear. To prevent heat damage, the screen saver function is effective. For details on the screen saver function, refer to the following.
Chapter 12 DISPLAY AND OPERATION SETTINGS (GOT SET UP)
*2: For the details of system information, refer to the following.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual
*3: ROM in which new data can be written without deleting the written data.
*4: Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting
GOT multidrop connection. For details of GOT multidrop connection, refer to the following.
GOT1000 Series Connection Manual
*5: Note that this does not guarantee all users’ operation environment.
1
2
3
4
5
6
7
8
3.2 Performance Specifications
3 - 3
Item
Type
Screen size
Resolution
GT1020-LBDW/LWDW
Specifications
GT1020-LBDW2/LWDW2
STN monochrome (white/black) liquid crystal
3.7"
GT1020-LBLW/LWLW
160 64 dots (Horizontal format)
Display section
*1
Backlight
Display size
W86.4(3.4) H34.5(1.35) [mm](inch) (Horizontal format)
Display character 16-dot standard font: 20 characters 4 lines (Horizontal format)
Display color
Display angle
Monochrome (white/black)
Left/Right: 30 degrees, Top: 20 degrees, Bottom: 30 degrees (Horizontal format)
Contrast adjustment 16-level adjustment
Intensity of LCD only
300 [cd/m
2
] (in white)
Life
Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25 )
LED with 3 available colors (white, red, pink) (no replacement required),
Backlight status (colors, ON/BLINK/OFF) control, Adjustable screensaver activation time
Setting the system information
*2
enables PLC to control the backlight status.
Number of touch keys Maximum 50 keys/screen (Analog resistive film touch panel)
Key size
Minimum 2 2 dots (per key)
Touch panel
Memory
Simultaneous pressing of two (or more) areas
(2-point press)
Not supported
(Simultaneous pressing of two or more areas on the screen may activate the switch between those areas.)
Life
User memory
*3
1 million times or more (operating force 0.98N max.)
Flash memory (Internal), for storing project data (512 Kbytes or less), OS, Alarm history and
Recipe data
Life (Number of write times)
100,000 times
Built-in interface
PLC communication
PC communication
• RS-422 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
(Hardware version A to D)
• RS-422/485 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
Terminating resistor
*4
:
Open/110 /330
(Switched by terminating resistor selector switch) (At factory shipment: 330 )
(Hardware version E or later)
RS-232 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
RS-422 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
RS-232 1ch
Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape
Application
: MINI DIN 6 pins (Female)
: PC communication (Project data upload/download, OS installation, transparent function)
Buzzer output (a buzzer that sounds when touch keys are pressed)
Environmental protective structure
*5
External dimensions
Single tone (LONG/SHORT/OFF adjustable)
Equivalent to IP67 (JEM1030) (front section) (Horizontal format)
W113(4.44) H74(2.91) D27(1.06) [mm](inch) (Horizontal format)
Panel cutting dimensions
Weight
Compatible software package
W105(4.13) H66(2.59) [mm](inch) (Horizontal format)
0.2kg (Excluding mounting fixtures)
0.18kg (Excluding mounting fixtures)
GT Designer2 Version2.58L or later/GT Designer3 Version1.01B or later
3 - 4
3.2 Performance Specifications
*1: Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
Flickers may be observed depending on the display color.
Please note that these dots appear due to its characteristic and are not caused by product defect.
Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment. However, please note that these phenomena appear due to its characteristic and are not caused by product defect.
There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note that there is an individual difference between them.
A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.
When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.
Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.
When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.
To prevent heat damage, the screen saver function is effective.
For details on the screen saver function, refer to the following.
Chapter 12 DISPLAY AND OPERATION SETTINGS (GOT SET UP)
*2: For the details of system information, refer to the following.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual
*3: ROM in which new data can be written without deleting the written data
*4: Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting
GOT multidrop connection. For details of GOT multidrop connection, refer to the following.
GOT1000 Series Connection Manual
*5: Note that this does not guarantee all users’ operation environment.
1
2
3
4
5
6
7
8
3.2 Performance Specifications
3 - 5
3 - 6
• GT1030
Display section *1
Backlight
Touch panel
Memory
Battery
Item
Type
Screen size
Resolution
GT1030-LBD/LWD
Specifications
GT1030-LBD2/LWD2
STN monochrome (white/black) liquid crystal
4.5"
GT1030-LBL/LWL
288 96 dots (Horizontal format)
Display size
W109.42(4.3) H35.98(1.41) [mm](inch) (Horizontal format)
Display character
Display color
Display angle
16-dot standard font: 36 characters 6 lines (Horizontal format)
12-dot standard font: 48 characters 8 lines (Horizontal format)
Monochrome (white/black)
Left/Right: 30 degrees, Top: 20 degrees, Bottom: 30 degrees (Horizontal format)
Contrast adjustment 16-level adjustment
Intensity adjustment 8-level adjustment
Intensity of LCD only
200 [cd/m
2
] (in green)
Life
Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25 )
LED with 3 available colors (green, red, orange) (no replacement required),
Backlight status (colors, ON/BLINK/OFF) control, Adjustable screensaver activation time
Setting the system information
*2
enables PLC to control the backlight status.
Number of touch keys Maximum 50 keys/screen (Matrix resistive film touch panel)
Key size
Minimum 16 16 dots (per key)
Simultaneous pressing of two (or more) areas
(2-point press)
Life
Enable
1 million times or more (operating force 0.98N max.)
User memory *3
Life (Number of write times)
Flash memory (Internal), for storing project data (1.5Mbytes or less), OS
100,000 times
Backup target
GT11-50BAT lithium battery
Clock data, alarm history and recipe data
Built-in interface
Life
PLC communication
PC communication
Approx. 5 years (Operating ambient temperature of 25 )
• RS-422 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
(Hardware version A)
• RS-422/485 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
Terminating resistor
*4
:
Open/110 /330 (Switched by terminating resistor selector switch) (At factory shipment: 330 )
(Hardware version B or later)
RS-232 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
RS-422 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
RS-232 1ch
Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape
Application
: MINI DIN 6 pins (Female)
: PC communication (Project data upload/download, OS installation, transparent function)
Buzzer output (a buzzer that sounds when touch keys are pressed)
Single tone (LONG/SHORT/OFF adjustable)
Environmental protective structure *5 Equivalent to IP67 (JEM1030) (front section) (Horizontal format)
External dimensions
W145(5.7) H76(2.99) D29.5(1.16) [mm](inch) (Horizontal format)
3.2 Performance Specifications
Item
Panel cutting dimensions
Weight
Compatible software package
GT1030-LBD/LWD
Specifications
GT1030-LBD2/LWD2
W137(5.39) H66(2.59) [mm](inch) (Horizontal format)
0.3kg (Excluding mounting fixtures)
GT Designer2 Version2.58L or later/
GT Designer3 Version1.01B or later
GT1030-LBL/LWL
0.28kg
(Excluding mounting fixtures)
GT Designer2 Version2.97B or later/
GT Designer3 Version1.01B or later
*1: Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
Flickers may be observed depending on the display color.
Please note that these dots appear due to its characteristic and are not caused by product defect.
Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment. However, please note that these phenomena appear due to its characteristic and are not caused by product defect.
There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note that there is an individual difference between them.
A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.
When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.
Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.
When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.
To prevent heat damage, the screen saver function is effective.
For details on the screen saver function, refer to the following.
Chapter 12 DISPLAY AND OPERATION SETTINGS (GOT SET UP)
*2: For the details of system information, refer to the following.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual
*3: ROM in which new data can be written without deleting the written data.
*4: Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting
GOT multidrop connection. For details of GOT multidrop connection, refer to the following.
GOT1000 Series Connection Manual
*5: Note that this does not guarantee all users’ operation environment.
1
2
3
4
5
6
7
8
3.2 Performance Specifications
3 - 7
3 - 8
Display section *1
Backlight
Touch panel
Item
Type
Screen size
Resolution
GT1030-LBDW/LWDW
Specifications
GT1030-LBDW2/LWDW2
STN monochrome (white/black) liquid crystal
4.5"
GT1030-LBLW/LWLW
288 96 dots (Horizontal format)
Display size
Display character
Display color
Display angle
W109.42(4.3) H35.98(1.41) [mm](inch) (Horizontal format)
16-dot standard font: 36 characters 6 lines (Horizontal format)
12-dot standard font: 48 characters 8 lines (Horizontal format)
Monochrome (white/black)
Left/Right: 30 degrees, Top: 20 degrees, Bottom: 30 degrees (Horizontal format)
Contrast adjustment 16-level adjustment
Intensity adjustment 8-level adjustment
Intensity of LCD only
300 [cd/m
2
] (in white)
Life
Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25 )
LED with 3 available colors (white, red, pink) (no replacement required),
Backlight status (colors, ON/BLINK/OFF) control, Adjustable screensaver activation time
Setting the system information
*2
enables PLC to control the backlight status.
Number of touch keys Maximum 50 keys/screen (Matrix resistive film touch panel)
Key size
Minimum 16 16 dots (per key)
Simultaneous pressing of two (or more) areas
(2-point press)
Life
Enable
1 million times or more (operating force 0.98N max.)
Memory
User memory *3
Life (Number of write times)
Flash memory (Internal), for storing project data (1.5Mbytes or less), OS
100,000 times
Battery
Built-in interface
Backup target
Life
PLC communication
GT11-50BAT lithium battery
Clock data, alarm history and recipe data
Approx. 5 years (Operating ambient temperature of 25 )
• RS-422 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:PLC communication
(Hardware version A)
• RS-422/485 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:PLC communication
Terminating resistor
*4
:
Open/110 /330 (Switched by terminating resistor selector switch) (At factory shipment: 330 )
(Hardware version B or later)
RS-232 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
RS-422 1ch
Transmission speed:
115,200/57,600/38,400/
19,200/9,600/4,800bps
Connector shape:
Connector terminal block 9 pins
Application:
PLC communication
PC communication
RS-232 1ch
Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape
Application
: MINI DIN 6 pins (Female)
: PC communication (Project data upload/download, OS installation, transparent function)
Buzzer output (a buzzer that sounds when touch keys are pressed)
Single tone (LONG/SHORT/OFF adjustable)
Environmental protective structure *5 Equivalent to IP67 (JEM1030) (front section) (Horizontal format)
External dimensions
Panel cutting dimensions
W145(5.7) H76(2.99) D29.5(1.16) [mm](inch) (Horizontal format)
W137(5.39) H66(2.59) [mm](inch) (Horizontal format)
3.2 Performance Specifications
Item
Weight
Compatible software package
GT1030-LBDW/LWDW
0.3kg (Excluding mounting fixtures)
Specifications
GT1030-LBDW2/LWDW2
GT Designer2 Version2.58L or later/
GT Designer3 Version1.01B or later
GT1030-LBLW/LWLW
0.28kg (Excluding mounting fixtures)
GT Designer2 Version2.97B or later/
GT Designer3 Version1.01B or later
1
*1: Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
Flickers may be observed depending on the display color.
Please note that these dots appear due to its characteristic and are not caused by product defect.
Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment. However, please note that these phenomena appear due to its characteristic and are not caused by product defect.
There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note that there is an individual difference between them.
A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.
When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.
Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.
When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.
To prevent heat damage, the screen saver function is effective.
For details on the screen saver function, refer to the following.
Chapter 12 DISPLAY AND OPERATION SETTINGS (GOT SET UP)
*2: For the details of system information, refer to the following.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual
*3: ROM in which new data can be written without deleting the written data.
*4: Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting
GOT multidrop connection. For details of GOT multidrop connection, refer to the following.
GOT1000 Series Connection Manual
*5: Note that this does not guarantee all users’ operation environment.
2
3
4
5
6
7
8
3.2 Performance Specifications
3 - 9
• GT104
Display section
*1
Backlight
Touch panel
Memory
Battery
Built-in interface
Item
Memory board
Buzzer output (a buzzer that sounds when touch keys are pressed)
Environmental protective structure
*3
GT1045-QSBD
STN color liquid crystal
4.7"
320 240 dots (Horizontal format)
Specifications
GT1040-QBBD
STN monochrome (white/blue) liquid crystal Type
Screen size
Resolution
Display size
Display character
Display color
Display angle
256 colors
Left/Right: 50 degrees, Top: 40 degrees,
Bottom: 70 degrees (Horizontal format)
Contrast adjustment 16-level adjustment
Monochrome (white/blue), 16 scales
Left/Right: 45 degrees, Top: 20 degrees,
Bottom: 40 degrees (Horizontal format)
Intensity of LCD only
150 [cd/m
2
]
Life
300 [cd/m
2
]
Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25 )
LED Backlight off/screen saving time can be set.
Number of touch keys Maximum 50 keys/screen (Matrix resistive film touch panel)
Key size Minimum 16 16 dots (per key)
Number of points touched simultaneously Maximun of 2 points
Life
User memory
*2
Life (Number of write times)
1 million times or more (operating force 0.98N max.)
Flash memory (Internal), for storing project data (3Mbytes or less), OS
100,000 times
Backup target
GT11-50BAT lithium battery
Clock data, alarm history and recipe data
Life
W96(3.77) H72(2.83) [mm](inch) (Horizontal format)
16-dot standard font: 40 characters 15 lines (Horizontal format)
12-dot standard font: 53 characters 20 lines (Horizontal format)
RS-422
RS-232
USB
Approx. 5 years (Operating ambient temperature of 25 )
RS-422/485 1ch
Transmission speed :115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape
Application
:D-sub 9 pins (Female)
:PLC communication
Terminating resistor *4 :Open/110 /330 (Switched by terminating resistor selector switch)
RS-232 1ch
Transmission speed :115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape
Application
:D-sub 9 pins (Male)
:PLC communication, bar code reader connection, PC communication (Project data upload/download, OS installation, transparent function)
USB (Full Speed 12Mbps) 1ch
Connector shape
Application
:Mini-B (Receptacle)
:PC communication (Project data upload/download, OS installation, transparent function)
For connecting memory board (GT10-50FMB), 1ch
Single tone (LONG/SHORT/OFF adjustable)
External dimensions
Panel cutting dimensions
Weight
Compatible software package
Equivalent to IP67 (JEM1030) (front section) (Horizontal format)
W139(5.47) H112(4.4) D41(1.61) (Excluding mounting fixtures) [mm](inch)
(Horizontal format)
W130(5.11) H103(4.05) [mm](inch) (Horizontal format)
0.45kg (Excluding mounting fixtures)
GT Designer2 Version2.90U or later/GT Designer3 Version1.01B or later
3 - 10
3.2 Performance Specifications
*1: Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
Flickers may be observed depending on the display color.
Please note that these dots appear due to its characteristic and are not caused by product defect.
Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment. However, please note that these phenomena appear due to its characteristic and are not caused by product defect.
There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note that there is an individual difference between them.
A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.
When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.
Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.
When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.
To prevent heat damage, the screen saver function is effective.
For details on the screen saver function, refer to the following.
Chapter 12 DISPLAY AND OPERATION SETTINGS (GOT SET UP)
*2: ROM in which new data can be written without deleting the written data.
*3: Note that this does not guarantee all users' operation environment.
*4: Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting
GOT multidrop connection.
For details of GOT multidrop connection, refer to the following.
GOT1000 Series Connection Manual
1
2
3
4
5
6
7
8
3.2 Performance Specifications
3 - 11
• GT105
Display section *1
Backlight
Touch panel
Memory
Battery
Item
Type
Screen size
Resolution
Display size
Display character
GT1055-QSBD
STN color liquid crystal
5.7"
320 240 dots (Horizontal format)
Specifications
GT1050-QBBD
STN monochrome (white/blue) liquid crystal
W115(4.53) H86(3.39) [mm](inch) (Horizontal format)
16-dot standard font: 40 characters 15 lines (Horizontal format)
12-dot standard font: 53 characters 20 lines (Horizontal format)
Display color
Display angle
Life
*2
256 colors
Left/Right: 55 degrees, Top: 65 degrees,
Bottom: 70 degrees (Horizontal format)
Monochrome (white/blue), 16 scales
Left/Right: 45 degrees, Top: 20 degrees,
Bottom: 40 degrees (Horizontal format)
Contrast adjustment 16-level adjustment
Intensity of LCD only
Life
380 [cd/m
2
] 260 [cd/m
2
]
Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25 )
Cold cathode fluorescent tube (irreplaceable by a user) backlight shutoff detection function is included. Backlight off/screen saving time can be set.
Approx. 75,000h or longer (Time for display intensity reaches 50% at the operating ambient temperature of 25 )
Approx. 54,000h or longer (Time for display intensity reaches 50% at the operating ambient temperature of 25 )
Number of touch keys Maximum 50 keys/screen (Matrix resistive film touch panel)
Key size Minimum 16 16 dots (per key)
Number of points touched simultaneously Maximun of 2 points
Life 1 million times or more (operating force 0.98N max.)
User memory *3
Life (Number of write times)
Flash memory (Internal), for storing project data (3Mbytes or less), OS
100,000 times
Backup target
GT11-50BAT lithium battery
Clock data, alarm history and recipe data
Built-in interface
Life
RS-422
RS-232
USB
Approx. 5 years (Operating ambient temperature of 25 )
• RS-422 1ch
Transmission speed :115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape
Application
:D-sub 9 pins (Female)
:PLC communication
(Hardware version A to B)
• RS-422/485 1ch
Transmission speed :115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape
Application
Terminating resistor
*4
:D-sub 9 pins (Female)
:PLC communication
:Open/110 /330 (Switched by terminating resistor selector switch)
(At factory shipment: 330 )
(Hardware version C or later)
RS-232 1ch
Transmission speed :115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape
Application
:D-sub 9 pins (Male)
:PLC communication, bar code reader connection, PC communication (Project data upload/download, OS installation, transparent function)
USB (Full Speed 12Mbps) 1ch
Connector shape
Application
:Mini-B (Receptacle)
:PC communication (Project data upload/download, OS installation, transparent function)
For connecting memory board (GT10-50FMB), 1ch Memory board
Buzzer output (a buzzer that sounds when touch keys are pressed)
Environmental protective structure
*5
Single tone (LONG/SHORT/OFF adjustable)
External dimensions
Panel cutting dimensions
Weight
Compatible software package
Equivalent to IP67 (JEM1030) (front section) (Horizontal format)
W164(6.46) H135(5.32) D56(2.21) (Excluding mounting fixtures) [mm](inch)
(Horizontal format)
W153(6.03) H121(4.77) [mm](inch) (Horizontal format)
0.7kg (Excluding mounting fixtures)
GT Designer2 Version2.90U or later/GT Designer3 Version1.01B or later
3 - 12
3.2 Performance Specifications
*1: Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
Flickers may be observed depending on the display color.
Please note that these dots appear due to its characteristic and are not caused by product defect.
Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment. However, please note that these phenomena appear due to its characteristic and are not caused by product defect.
There is a difference in the display brightness and the color tones between liquid crystal display panels. When using multiple liquid crystal display panels, please note that there is an individual difference between them.
A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic.
When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.
Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.
When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not disappear.
To prevent heat damage, the screen saver function is effective.
For details on the screen saver function, refer to the following.
Chapter 12 DISPLAY AND OPERATION SETTINGS (GOT SET UP)
*2: Using the GOT Backlight OFF function can prolong the life of the backlight.
For details on the Backlight OFF function, refer to the following.
Chapter 12 DISPLAY AND OPERATION SETTINGS (GOT SET UP)
*3: ROM in which new data can be written without deleting the written data.
*4: Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting
GOT multidrop connection. For details of GOT multidrop connection, refer to the following.
GOT1000 Series Connection Manual
*5: Note that this does not guarantee all users’ operation environment.
1
2
3
4
5
6
7
8
3.2 Performance Specifications
3 - 13
3.3 Power Supply Specifications
• GT1020, GT1030
Item
Input power supply voltage
Fuse (built-in, not exchangeable)
Power consumption
At backlight off
Inrush current
GT1020-LBD GT1020-LWD
GT1020-LBD2 GT1020-LWD2
GT1020-LBDW GT1020-LWDW
GT1020-LBDW2 GT1020-LWDW2
Specifications
GT1030-LBD GT1030-LWD
GT1030-LBD2 GT1030-LWD2
GT1030-LBDW GT1030-LWDW
GT1030-LBDW2 GT1030-LWDW2
24VDC (+10% -15%), ripple voltage 200mV or less
0.4A
1.9W (80mA/24VDC) or less
1.2W (50mA/24VDC) or less
13A or less
(26.4VDC) 1ms
0.5A
2.2W (90mA/24VDC) or less
1.7W (70mA/24VDC) or less
18A or less
(26.4VDC) 1ms
Permissible instantaneous power failure time
Noise immunity
Dielectric withstand voltage
Insulation resistance
Within 5ms
GT1020-LBL GT1020-LWL
GT1020-LBLW GT1020-LWLW
GT1030-LBL GT1030-LWL
GT1030-LBLW GT1030-LWLW
5VDC (±5%), supplied from the PLC
-
1.1W (220mA/5VDC) or less
0.6W (120mA/5VDC) or less
-
-
Noise voltage: 1000Vp-p
Noise width: 1 s (by noise simulator of 30 to 100Hz noise frequency)
500VAC for 1 minute
(across power supply terminals and earth)
-
10M or larger by insulation resistance tester
(across power supply terminals and earth)
-
Remark
Operation at momentary power failure
The GOT continues to operate even upon 5ms or shorter instantaneous power failure.
The GOT stops operating if there is extended power failure or voltage drop, while it automatically resumes operation as soon as the power is restored.
3 - 14
3.3 Power Supply Specifications
• GT104 , GT105
Item
Input power supply voltage
Fuse (built-in, not exchangeable)
Power consumption
At backlight off
Inrush current
Permissible instantaneous power failure time
Noise immunity
Dielectric withstand voltage
Insulation resistance
GT1045-QSBD
Specifications
GT1040-QBBD GT1055-QSBD
24VDC (+10% -15%), ripple voltage 200mV or less
1.0A
GT1050-QBBD
3.6W (150mA/24VDC) or less
2.9W (120mA/24VDC) or less
15A or less (26.4VDC) 2ms
Within 5ms
9.84W (410mA/
24VDC) or less
9.36W (390mA/
24VDC) or less
4.32W (180mA/24VDC) or less
Noise voltage : 1000Vp-p
Noise width : 1 s (by noise simulator of 30 to 100Hz noise frequency)
500VAC for 1 minute (across power supply terminals and earth)
10M or larger by insulation resistance tester
(across power supply terminals and earth)
Remark
Operation at momentary power failure
The GOT continues to operate even upon 5ms or shorter instantaneous power failure.
The GOT stops operating if there is extended power failure or voltage drop, while it automatically resumes operation as soon as the power is restored.
1
2
3
4
5
6
7
8
3.3 Power Supply Specifications
3 - 15
4. PART NAME
4.1 Front Panel
4.1.1
GT1020, GT1030
MITSUBISHI
GOT
1000
1) 2)
No.
Name
1) Display screen
2) Touch key
4.1.2
GT104
[ ]
Specifications
Displays the utility screen and the user creation screen.
GT1020 : 160 64 dots, STN monochrome (white/black) liquid crystal
GT1030 : 288 96 dots, STN monochrome (white/black) liquid crystal
For operating the touch switches in the utility screen and the user creation screen
MITSUBISHI
GOT
1000
1) 2)
4 - 1
No.
1)
2)
Name
Display screen
Touch key
Specifications
Displays the utility screen and the user creation screen.
GT1045-QSBD : 320 240 dots, STN color liquid crystal
GT1040-QBBD : 320 240 dots, STN monochrome (white/blue) liquid crystal
For operating the touch switches in the utility screen and the user creation screen
4.1 Front Panel
4.1.1 GT1020, GT1030
4.1.3
GT105
[ ]
1
2
1) 2)
3
3)
No.
Name
1) Display screen
2) Touch key
3) POWER LED
Specifications
Displays the utility screen and the user creation screen.
GT1055-QSBD : 320 240 dots, STN color liquid crystal
GT1050-QBBD : 320 240 dots, STN monochrome (white/blue) liquid crystal
For operating the touch switches in the utility screen and the user creation screen
Green light : Power is supplied
Orange light : Screeen saving (At backlight off)
Green / Orange flashing : Blown backlight bulb
POWER LED is not lit : Power is not supplied
4
5
6
7
8
4.1 Front Panel
4.1.3 GT105[ ]
4 - 2
4.2 Back Panel
4.2.1
GT1020-LBD/LWD/LBDW/LWDW
1) 2) 1)
(Hardware version A to D)
2) 3)
RS-422
SDA
SDB
RDA
RDB
SG
RSA
RSB
CSA
CSB
+
-
INPUT
24VDC
(FG)
RS-232
(Hardware version E or later)
4)
5)
4 - 3
4.2 Back Panel
4.2.1 GT1020-LBD/LWD/LBDW/LWDW
6)
5)
No.
Name
1) PLC connection interface (RS-422)
2) Power terminal
3) PC connection interface (RS-232)
4) Rating plate (nameplate)
5) Hole for unit installation fitting
6)
Terminating resistor selector switch
(TERM.)
Specifications
For connection to a controller (PLC) (9-pin connector terminal block)
24VDC (+10% -15%)
For PC connection (OS installation, Project data, download, transparent)
(MINI-DIN 6 pins, female)
−
Hole for mounting fitting (supplied) to mount the GOT on the panel
(4 holes at the top and bottom)
Terminating resistor selector of RS422/485
(330 /OPEN/110 ) (At factory shipment: 330 )
For the connection to the controller (PLC) or PC, refer to the following.
GOT 1000 Series Connection Manual
1
2
3
4
5
6
7
8
4.2 Back Panel
4.2.1 GT1020-LBD/LWD/LBDW/LWDW
4 - 4
4.2.2
GT1020-LBD2/LWD2/LBDW2/LWDW2
1) 2) 1) 2) 3)
RS-232
SD
RS
CS
NC
NC
RD
ER
DR
SG
+
-
INPUT
24VDC
(FG)
RS-232
4)
5) 5)
No.
Name
1) PLC connection interface (RS-232)
2) Power terminal
3) PC connection interface (RS-232)
4) Rating plate (nameplate)
5) Hole for unit installation fitting
Specifications
For connection to a controller (PLC) (9-pin connector terminal block)
24VDC (+10% -15%)
For PC connection (OS installation, Project data, download, transparent)
(MINI-DIN 6 pins, female)
−
Hole for mounting fitting (supplied) to mount the GOT on the panel
(4 holes at the top and bottom)
For the connection to the controller (PLC) or PC, refer to the following.
GOT 1000 Series Connection Manual
4 - 5
4.2 Back Panel
4.2.2 GT1020-LBD2/LWD2/LBDW2/LWDW2
4.2.3
GT1020-LBL/LWL/LBLW/LWLW
1) 1) 2)
1
2
3)
SDA
SDB
RDA
RDB
SG
RSA
RSB
-- INPUT
+ 5VDC
RS-232
3
4
No.
Name
1) PLC connection interface (RS-422)
2) PC connection interface (RS-232)
3) Rating plate (nameplate)
4) Hole for unit installation fitting
4) 4)
Specifications
For connection to a controller (PLC) (9-pin connector terminal block)
For PC connection (OS installation, Project data download, transparent)
(MINI-DIN 6 pins, female)
−
Hole for mounting fitting (supplied) to mount the GOT on the panel
(4 holes at the top and bottom)
For the connection to the controller (PLC) or PC, refer to the following.
GOT 1000 Series Connection Manual
5
6
7
8
4.2 Back Panel
4.2.3 GT1020-LBL/LWL/LBLW/LWLW
4 - 6
4.2.4
GT1030-LBD/LWD/LBDW/LWDW
1) 2) 1)
(Hardware version A)
2) 3)
3)
(Hardware version B or later)
7)
Battery cover opened
5)
8)
5)
4)
6)
4 - 7
4.2 Back Panel
4.2.4 GT1030-LBD/LWD/LBDW/LWDW
No.
Name
1) PLC connection interface (RS-422)
2) Power terminal
3) PC connection interface (RS-232)
4) Rating plate (nameplate)
5) Hole for unit installation fitting
6) Battery cover
7) Battery
Specifications
For connection to a controller (PLC) (9-pin connector terminal block)
24VDC (+10% -15%)
For PC connection (OS installation, Project data, download, transparent)
(MINI-DIN 6 pins, female)
−
Hole for mounting fitting (supplied) to mount the GOT on the panel
(4 holes at the top and bottom)
Open or close when replacing the battery.
GT11-50BAT battery for storing clock data, alarm history and recipe data
(The project data is stored in the built-in flash memory.)
Terminating resistor selector of RS422/485
(330 /OPEN/110 ) (At factory shipment: 330 )
For the connection to the controller (PLC) or PC, refer to the following.
GOT 1000 Series Connection Manual
1
2
3
4
5
6
7
8
4.2 Back Panel
4.2.4 GT1030-LBD/LWD/LBDW/LWDW
4 - 8
4.2.5
GT1030-LBD2/LWD2/LBDW2/LWDW2
1) 2) 1) 2) 3)
4)
6)
Battery cover opened
7)
5) 5)
No.
Name
1) PLC connection interface (RS-232)
2) Power terminal
3) PC connection interface (RS-232)
4) Rating plate (nameplate)
5) Hole for unit installation fitting
6) Battery cover
7) Battery
Specifications
For connection to a controller (PLC) (9-pin connector terminal block)
24VDC (+10% -15%)
For PC connection (OS installation, Project data, download, transparent)
(MINI-DIN 6 pins, female)
−
Hole for mounting fitting (supplied) to mount the GOT on the panel
(4 holes at the top and bottom)
Open or close when replacing the battery.
GT11-50BAT battery for storing clock data, alarm history and recipe data
(The project data is stored in the built-in flash memory.)
For the connection to the controller (PLC) or PC, refer to the following.
GOT 1000 Series Connection Manual
4 - 9
4.2 Back Panel
4.2.5 GT1030-LBD2/LWD2/LBDW2/LWDW2
4.2.6
GT1030-LBL/LWL/LBLW/LWLW
1)
1) 2)
1
2
3)
5)
3
Battery cover opened
6)
4
4) 4)
No.
Name
1) PLC connection interface (RS-422)
2) PC connection interface (RS-232)
3) Rating plate (nameplate)
4) Hole for unit installation fitting
5) Battery cover
6) Battery
Specifications
For connection to a controller (PLC) (9-pin connector terminal block)
For communicating with controller (PLC, microcomputer board, etc)
(D-sub 9-pin female)
−
Hole for mounting fitting (supplied) to mount the GOT on the panel
(4 holes at the top and bottom)
Open or close when replacing the battery.
GT11-50BAT battery for storing clock data, alarm history and recipe data
(The project data is stored in the built-in flash memory.)
For the connection to the controller (PLC) or PC, refer to the following.
GOT 1000 Series Connection Manual
5
6
7
8
4.2 Back Panel
4.2.6 GT1030-LBL/LWL/LBLW/LWLW
4 - 10
4.2.7
GT1045-QSBD/GT1040-QBBD
6)
1)
2)
Battery cover opened
12)
8)
9)
10) 11) 3) 4) 5)
7) 7)
No.
Name
1) PLC connection interface (RS-232)
2) PLC connection interface (RS-422)
3) USB interface
4) USB cover
5) Power terminal
6) Rating plate (nameplate)
7) Hole for unit installation fitting
8) Battery cover
9) Battery
10) Memory board cover
11) Memory board interface
12) Terminating resistor selector switch
Specifications
For communicating with controller (PLC, microcomputer board, bar code reader, etc) or personal computer (OS installation, project data download, transparent) (D-sub 9-pin male)
For communicating with controller (PLC, microcomputer board, etc)
(D-sub 9-pin female)
For PC connection (OS installation, project data download, transparent)
(Mini-B Receptacle)
Open or close when using the USB interface
Power terminal and FG terminal (for power supply (24VDC) to GOT and grounding)
−
Hole for the inserting installation fittings (accessory) during the GOT installation to the panel (4 holes at top and bottom)
Open or close when replacing the battery.
GT11-50BAT battery for storing clock data, alarm history and recipe data
(The project data is stored in the built-in flash memory.)
Remove when using the memory board.
Interface for mounting the memory board to the GOT.
Terminating resistor selector of RS422/485
(330 /OPEN/110 ) (At factory shipment: 330 )
For the connection to the controller (PLC) or PC, refer to the following.
GOT 1000 Series Connection Manual
4 - 11
4.2 Back Panel
4.2.7 GT1045-QSBD/GT1040-QBBD
4.2.8
GT1055-QSBD/GT1050-QBBD
1) 2) 7)
1
Battery cover opened
(Hardware version A to B)
2
5) 6) 9)
10)
3) 4) 11) 12)
(Hardware version
C or later)
Power supply terminal layout
3
4
13)
8) 8)
No.
Name
1) PLC connection interface (RS-232)
2) PLC connection interface (RS-422)
3) USB interface
4) USB cover
5) Power terminal
6) Power terminal cover
7) Rating plate (nameplate)
8) Hole for unit installation fitting
9) Battery cover
10) Battery
11) Memory board cover
12) Memory board interface
Specifications
For communicating with controller (PLC, microcomputer board, bar code reader, etc) or personal computer (OS installation, project data download, transparent) (D-sub 9-pin male)
For communicating with controller (PLC, microcomputer board, etc)
(D-sub 9-pin female)
For PC connection (OS installation, project data download, transparent)
(Mini-B Receptacle)
Open or close when using the USB interface
Power terminal and FG terminal (for power supply (24VDC) to GOT and grounding)
Open or close when connecting a power terminal. (Color: transparent)
(Hardware version B or later)
−
Hole for the inserting installation fittings (accessory) during the GOT installation to the panel (4 holes at top and bottom)
Open or close when replacing the battery.
GT11-50BAT battery for storing clock data, alarm history and recipe data
(The project data is stored in the built-in flash memory.)
Remove when using the memory board.
Interface for mounting the memory board to the GOT.
Terminating resistor selector of RS422/485
(330 /OPEN/110 ) (At factory shipment: 330 )
For the connection to the controller (PLC) or PC, refer to the following.
GOT 1000 Series Connection Manual
4.2 Back Panel
4.2.8 GT1055-QSBD/GT1050-QBBD
4 - 12
5
6
7
8
5. EMC DIRECTIVE
For the products sold in European countries, the conformance to the EMC Directive, which is one of the
European Directives, has been a legal obligation since 1996. Also, conformance to the Low Voltage
Directive, another European Directives, has been a legal obligation since 1997.
Manufacturers who recognize their products must conform to the EMC required to declare that their products conform to these Directives and put a "CE mark" on their products.
Products that the EMC Directive applies to are marked with the CE mark logo.
Authorized representative in Europe
• This product is designed for use in industrial applications.
• Manufactured by: Mitsubishi Electric Corporation
2-7-3 Marunouchi, Chiyoda-ku, Tokyo 100-8310 Japan
• Manufactured at: Mitsubishi Electric Corporation Himeji Works
840 Chiyoda-machi, Himeji, Hyogo 670-8677 Japan
• Authorized Representative in the European Community: Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany.
5.1 Requirements for Conformance to EMC Directive
The EMC Directive specifies that products placed on the market must "be so constructed that they do not cause excessive electromagnetic interference (emissions) and are not unduly affected by electromagnetic interference (immunity)".
The applicable products are requested to meet these requirements.
machinery constructed using the GOT.
The details of these precautions has been prepared based on the requirements and the applicable standards control. However, we will not assure that the overall machinery manufactured according to these details conforms to the above-mentioned directives. The method of conformance to the EMC Directive and the judgment on whether or not the machinery conforms to the EMC Directive must be determined finally by the manufacturer of the machinery.
5.1.1
Standards applicable to the EMC Directive
The following products have shown compliance through direct testing (to the identified standards) and design analysis (forming a technical construction file) to the European Directive for Electromagnetic
Compatibility (2004/108/EC) when used as directed by the appropriate documentation.
Type : Programmable Controller (Open Type Equipment)
Standard
EN61131-2 : 2003
Programmable controllers
- Equipment, requirement and tests
EMI
EMS
Remark
Compliance with all relevant aspects of the standard.
(Radiated Emissions)
Compliance with all relevant aspects of the standard.
(ESD,RF electromagnetic field, EFTB, Surge, RF conducted disturbances and Power frequency magnetic field)
For more details please contact the local Mitsubishi Electric sales site.
5 - 1
5.1 Requirements for Conformance to EMC Directive
5.1.1 Standards applicable to the EMC Directive
5.1.2
About models applicable to the EMC Directive
The following table lists the modules compliant with the EMC Directive.
: Compliant with EMC Directive : Not compliant with EMC Directive
EMC Directive Hardware version Item
GT1020-LBD/LWD/LBD2/LWD2/LBL/LWL/
LBDW/LWDW/LBDW2/LWDW2/LBLW/LWLW
GT1030-LBD/LWD/LBD2/LWD2/LBDW/LWDW/
LBDW2/LWDW2
GT1045-QSBD, GT1040-QBBD
A
A
A
GT1055-QSBD, GT1050-QBBD A
Please use the GOT whose hardware version is later than that described.
Confirm the hardware version with the products rating plate.
(Products that the EMC Directive applies to are marked with the CE mark logo.)
GRAPHIC OPERATION TERMINAL
MODEL
IN 20.4
GT1020-LBD
26.4VDC POWER 1.9W MAX
SERIAL 6Y0001 AB
MITSUBISHI ELECTRIC CORPORATION
MADE IN JAPAN
JY204D42501C
80M1 IND. CONT. EQ
US LISTED
AB
Hardware version
1
2
3
4
5
6
7
8
5.1 Requirements for Conformance to EMC Directive
5.1.2 About models applicable to the EMC Directive
5 - 2
5.1.3
About the cable used
1
General notes on the use of communication cables
Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise. Therefore, when installing any communication cables care should always be taken with the routing and location of those cables. The GOT units identified on the previous page are compliant with the EMC requirement when the following communication cables are used.
Existing Cables User Made Cables GOT Unit
GT1020-LBD/LWD/LBL/LWL/
LBDW/LWDW/LBLW/LWLW
GT1030-LBD/LWD/LBDW/LWDW
GT1020-LBD2/LWD2/
LBDW2/LWDW2
GT1030-LBD2/LWD2/
LBDW2/LWDW2
GT10-C30R4-8P
(For Melsec FX series PLC)
GT10-C30R2-6P
(For Melsec Q series PLC)
-
-
GT1045-QSBD
GT1040-QBBD
GT1055-QSBD
GT1050-QBBD
GT01-C30R4-8P modified as shown in EX.1
GT01-C30R4-8P modified as shown in EX.1
Those cables need to be independently tested by the user to demonstrate EMC compatibility when they are used with
Mitsubishi GOT unit and FX3U Programmable Controllers.
Those cables need to be independently tested by the user to demonstrate EMC compatibility when they are used with
Mitsubishi GOT unit and FX3U Programmable Controllers.
Ex.1
F = Ferrite core
Ex. NEC TOKIN - ESD-R-17S or similar
GT01-C30R4-8P
250mm
(9.84inch)
Programmable controller
F F F
100mm
(3.93inch)
140mm
(5.51inch)
Comes equipped
Added by user Added by user
GOT units
2
General notes on the use of the power cable
The GT1020-LBD/LWD/LBD2/LWD2/LBDW/LWDW/LBDW2/LWDW2 and GT1030-LBD/LWD/LBD2/
LWD2/LBDW/LWDW/LBDW2/LWDW2 unit demand that the cable for the power supply is 10m or less.
The GT1045-QSBD, GT1040-QBBD, GT1055-QSBD and GT1050-
QBBD unit requires an additional ferrite filter to be attached to the
24V DC power supply cables. The filter should be attached in a similar manner as shown in the figure opposite, i.e. the power cables are wrapped around the filter.
However, as with all EMC situations the more correctly applied precautions the better the systems Electro-magnetic Compatibility.
The ferrite recommended is a TDK ZCAT3035-1330 or similar.
The ferrite should be placed as near to the 24V DC terminals of the GT1045-QSBD, GT1040-QBBD, GT1055-QSBD and GT1050-
QBBD as possible (which should be within 75mm of the GOT terminal).
Up to
75mm
(2.95inch)
INPUT
24V DC
5 - 3
5.1 Requirements for Conformance to EMC Directive
5.1.3 About the cable used
6. INSTALLATION
MOUNTING PRECAUTIONS
DANGER
Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to/from the panel.
Not doing so can cause the unit to fail or malfunction.
Be sure to shut off all phases of the external power supply used by the system before mounting or removing the memory board on to/ from the GOT.
Not doing so can cause the unit to fail or malfunction.
When installing the memory board and the battery wear an earth band etc. to avoid the static electricity.
The static electricity can cause the unit to fail or malfunction.
MOUNTING PRECAUTIONS
CAUTION
Use the GOT in the environment that satisfies the general specifications described in this manual.
Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in the specified torque range.
Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or the
GOT.
Securely connect the memory board to the connector provided for the board.
2
3
4
5
6
1
7
8
6 - 1
6.1 Control Panel Inside Dimensions for Mounting
GOT
6.1.1
GT1020
Mount the GOT onto the control panel while considering the following control panel inside dimensions.
Horizontal format
23(0.9") 80(3.14") or more
4
(0.15")
9.5
(0.37")
3(0.11")
10
(0.39")
104(4.09")
76(2.99")
10
(0.39")
Mounting fixtures
RS-422
SDA
SDB
RDA
RDB
SG
RSA
RSB
CSA
CSB
+
-
INPUT
24VDC
(FG)
RS-232
RS-232 cable for connecting personal computer
25(0.98") to 28(1.1")
5
(0.19")
10
(0.39")
76(2.99")
10
(0.39")
Unit: mm(inch)
Vertical format
(If the vertical format is selected, the dimension, which is rotated 90 degrees clockwise looking from the display section side, is required.)
4
(0.15")
23(0.9") 80(3.14") or more
Mounting fixtures
84(3.3")
65(2.55")
6 - 2
RS-232 cable for connecting personal computer
25(0.98") to 28(1.1")
Unit: mm(inch)
Applicable cable
Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation.
6.1 Control Panel Inside Dimensions for Mounting GOT
6.1.1 GT1020
6.1.2
GT1030
Mount the GOT onto the control panel while considering the following control panel inside dimensions.
Horizontal format
4.5
(0.17")
25(0.98")
9.5
(0.37")
80(3.14") or more
16
(0.62")
10
(0.39")
136(5.35")
84(3.3")
10
(0.39")
Mounting fixtures
1
2
3
RS-232 cable for connecting personal computer
17 10 84(3.3") 10
Unit: mm(inch)
25.5(1") to 28.5(1.12")
(0.66") (0.39") (0.39")
Vertical format
(If the vertical format is selected, the dimension, which is rotated 90 degrees clockwise looking from the display section side, is required.)
4.5 25(0.98") 80(3.14") or more
84(3.3")
(0.17")
Mounting fixtures
65(2.55")
4
5
6
7
RS-232 cable for connecting personal computer
Unit: mm(inch)
25.5(1") to 28.5(1.12")
Applicable cable
Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation.
8
6.1 Control Panel Inside Dimensions for Mounting GOT
6.1.2 GT1030
6 - 3
6.1.3
GT104
[ ]
Mount the GOT onto the control panel while considering the following control panel inside dimensions.
Horizontal format
40
(1.57")
129(5.07")
Unit: mm(inch)
Vertical format
(If the vertical format is selected, the dimension, which is rotated 90 degrees clockwise looking from the display section side, is required.)
121(4.76")
102(4.01")
Unit: mm(inch)
Applicable cable
Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation.
6 - 4
6.1 Control Panel Inside Dimensions for Mounting GOT
6.1.3 GT104[ ]
6.1.4
GT105
[ ]
Mount the GOT onto the control panel while considering the following control panel inside dimensions.
Horizontal format
152 (5.99")
30
(1.19")
1
2
3
Unit:mm(inch)
Vertical format
(If the vertical format is selected, the dimension, which is rotated 90 degrees clockwise looking from the display section side, is required.)
140 (5.52")
120 (4.73")
4
5
6
Unit:mm(inch)
Applicable cable
Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation.
7
8
6.1 Control Panel Inside Dimensions for Mounting GOT
6.1.4 GT105[ ]
6 - 5
6.2 Panel Cutting Dimensions
6.2.1
Panel cutting dimensions
Cut holes in the following dimensions on the panel.
A space of top and bottom is required to allow for the attachment of mounting fixtures.
Horizontal format
A
Vertical format
C B C
Unit: mm(inch)
GOT
GT1020
GT1030
GT104
GT105
A [mm] (inch)
105 (4.13)
(+1(0.03), 0(0))
137 (5.39)
(+1(0.03), 0(0))
130(5.11)
(+1(0.03), 0(0))
153 (6.03)
(+2(0.07), 0(0))
B [mm] (inch)
66 (2.59)
(+1(0.03), 0(0))
66(2.59)
(+1(0.03), 0(0))
103(4.05)
(+1(0.03), 0(0))
121 (4.77)
(+2(0.07), 0(0))
C [mm] (inch)
13 (0.51”) or more
13 (0.51”) or more
13 (0.51”) or more
10 (0.39”) or more
Unit: mm(inch)
6 - 6
6.2 Panel Cutting Dimensions
6.2.1 Panel cutting dimensions
6.3 Mounting Position
6.3.1
Mounting position
When mounting the GOT, the following clearances must be maintained from other structures and devices.
Horizontal format (GT1020, GT1030)
Installation Environment
In the presence of radiated-noise or heat-generating equipment nearby
In the absence of radiated-noise or heat-generating equipment nearby
A
50 mm (1.97”) or more
20 mm (0.79”) or more
*1
B
50 mm (1.97”) or more
20 mm (0.79”) or more
C
50 mm (1.97”) or more
20 mm (0.79”) or more
D
50 mm (1.97”) or more
E
80 mm (3.14”) or more
20 mm (0.79”) or more
*2
*1 50 mm (1.97”) or more if an RS-232/USB conversion adaptor is used.
*2 80 mm (3.14”) or more if a PC connection cable is used or if an RS-232 interface for PC is used to connect multiple GOT units.
50 mm (1.97”) or more if an RS-232/USB conversion adaptor is used and is connected to the RS-232 interface for PC.
Horizontal format (GT104 , GT105 )
Installation Environment
In the presence of radiated-noise or heat-generating equipment nearby
In the absence of radiated-noise or heat-generating equipment nearby
A
50 mm (1.97”) or more
20 mm (0.79”) or more
B
80 mm (3.14”) or more
20 mm (0.79”) or more
*1 80 mm (3.14”) or more if an USB cable, memory board is used.
C
50 mm (1.97”) or more
20 mm (0.79”) or more
D
50 mm (1.97”) or more
20 mm (0.79”) or more
E
100 mm (3.94”) or more
20 mm (0.79”) or more
*1
Other device or control panel
1
2
3
4
5
B
MITSUBISHI
GOT
1000
C
D E
6
A
7
8
6.3 Mounting Position
6.3.1 Mounting position
6 - 7
Vertical format (GT1020, GT1030)
Installation Environment
In the presence of radiated-noise or heat-generating equipment nearby
In the absence of radiated-noise or heat-generating equipment nearby
A
50 mm (1.97”) or more
B
50 mm (1.97”) or more
20 mm (0.79”) or more
C
50 mm (1.97”) or more
20 mm (0.79”) or more
*1
D
50 mm (1.97”) or more
20 mm (0.79”) or more
E
80 mm (3.14”) or more
20 mm (0.79”) or more
*2
*1 50 mm (1.97”) or more if an RS-232/USB conversion adaptor is used.
*2 80 mm (3.14”) or more if a PC connection cable is used or if an RS-232 interface for PC is used to connect multiple GOT units.
50 mm (1.97”) or more if an RS-232/USB conversion adaptor is used and is connected to the RS-232 interface for PC.
Vertical format (GT104 , GT105 )
Installation Environment
In the presence of radiated-noise or heat-generating equipment nearby
In the absence of radiated-noise or heat-generating equipment nearby
A
50 mm (1.97”) or more
20 mm (0.79”) or more
B
50 mm (1.97”) or more
20 mm (0.79”) or more
C
80 mm (3.14”) or more
20 mm (0.79”) or more
*1 80 mm (3.14”) or more if an USB cable, memory board is used.
D
50 mm (1.97”) or more
20 mm (0.79”) or more
E
100 mm (3.94”) or more
20 mm (0.79”) or more
*1
Other device or control panel
B
C
D E
A
6 - 8
6.3 Mounting Position
6.3.1 Mounting position
6.4 Control Panel Temperature and Mounting Angle
6.4.1
Control panel temperature and mounting angle
When mounting the main unit to a control panel or similar fixture, set the GOT display section as shown below.
1
Horizontal installation
When the temperature inside the control panel is 40 to 55 , the mounting angle should be in the range from 60 to 105 degrees.
GOT back panel
105°
GOT display section
Control panel, etc.
60°
• The GOT will have a longer lifetime if used within the mounting angles shown above.
Ideally, the temperature inside the control panel should not exceed 0 to 40
2
Vertical installation
When the temperature inside the control panel is 40 to 50
, the mounting angle should be in the range from 60 to 105 degrees.
GOT back panel
105°
GOT display section
Control panel, etc.
60°
• The GOT will have a longer lifetime if used within the mounting angles shown above.
Ideally, the temperature inside the control panel should not exceed 0 to 40 .
1
2
3
4
5
6
7
8
6.4 Control Panel Temperature and Mounting Angle
6.4.1 Control panel temperature and mounting angle
6 - 9
6.5 Installation Procedure
6.5.1
Installation procedure
The GOT is designed to be embedded into a panel.
Mount the GOT by following the procedure below.
For panel cutting dimensions, refer to Section 6.2.
Note that the panel thickness should be within 1 to 4mm for GT1020 and GT1030 and within 2 to 5mm for
GT104 and GT105 .
1
Installing the packing
Install packing to the packing installation groove on the back panel of the GOT.
Packing
Magnified illustration
Packing
• For GT105
While referring to the cross sectional view of the packing shown right, push the thinner side into the packing groove. (Right drawing is the example of lateral format.)
Magnified illustration
Packing
Packing installation groove
Packing
Packing installation groove
Packing cross sectional view
Inserting direction
2
Inserting into the panel face
Insert the GOT from the front side of the panel.
(Right drawing is the example of lateral format.)
Mounting hole
6 - 10
6.5 Installation Procedure
6.5.1 Installation procedure
3
Fixing the GOT
1) Insert the hooks on the mounting fittings (supplied) into the mounting holes on the GOT unit.
2) Slide the mounting fittings to the back end.
3) Slide them to the left to lock them in place, and then fix them with the mounting screws (supplied).
The GOT will be fixed in 4 upper/lower parts.
Tighten the mounting screw with the specified torque.
(Failure to do so may distort the panel and make a surface waviness on the protective sheet.)
GOT
Tightening torque
GT1020, GT1030, GT104
0.20 to 0.25 N•m
GT105
0.3 to 0.5 N•m
Magnified illustration
Mounting screw
Mounting fitting
2)
3)
1)
Mounting fitting
Mounting screw
1
2
3
4
For GT1020, GT1030, GT104 For GT105
4
A protection film is attached on the display section of GOT prior to shipment.
Remove the film when the installation is completed.
5
6
7
8
6.5 Installation Procedure
6.5.1 Installation procedure
6 - 11
7. WIRING
WIRING PRECAUTIONS
DANGER
Be sure to shut off all phases of the external power supply used by the system before wiring.
Failure to do so may result in an electric shock, product damage or malfunctions.
Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT.
Not doing so may cause an electric shock or malfunction.
Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section in the specified torque range.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.
Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT.
Not doing so can cause a fire, failure or malfunction.
WIRING PRECAUTIONS
CAUTION
Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
This chapter describes the wiring to the GOT power supply section.
(1) For the connection with a PLC, refer to the following.
GOT1000 Series Connection Manual
7 - 1
Remark
General preventive measures against noise
There are two kinds of noises: Radiated noise that is transmitted into the air and
Conductive noise that is directly transmitted along connected lines.
Countermeasures must be taken considering both kinds of noises and referring to the following 3 points.
(1) Protecting against noise
(a) Keep signal lines away from noise sources such as a power cable or a highpower drive circuit.
(b) Shield the signal lines.
(2) Reducing generated noise
(a) Use a noise filter, etc. to reduce the level of the noise generated due to a source such as a high-power motor drive circuit.
(b) Attach surge killers to the terminals on the no fuse breakers (NFB), electromagnetic contactors, relays, solenoid valves, and generators to suppress noise interference.
(3) Releasing noise to the ground
(a) Make sure to connect the ground cable to the ground.
(b) Use a short and thick cable to lower its ground resistance.
(c) Ground the power system and the control system separately.
7.1 Power Supply Wiring
Connect the power supply to the power terminals on the back panel of the GOT.
Use a specified size power supply wire to prevent voltage drop, and tighten the terminal screws firmly to a specified torque.
Do not exceed the number of wires that are allowed to be connected.
Secure the wires to prevent stress from being directly applied to the terminal block or wire connections.
In the case of GT1020-LBL/LWL/LBLW/LWLW and GT1030-LBL/LWL/LBLW/LWLW, GOT power is supplied via the communication cable.
7.1.1
Cable types and wire end processing (GT1020, GT1030, GT104
[ ]
)
Process the end of the electrical wire (solid or stranded), or attach a ferrules with plastic sleeve to the wire end.
1
Electrical wire size
No. of wire per terminal
1
2
Solid wire
0.14 to 1.5mm
2
AWG26 to AWG16
0.14 to 0.5mm
2
AWG26 to AWG20
Electrical wire size
Stranded wire
0.14 to 1.0mm
2
AWG26 to AWG16
0.14 to 0.2mm
2
AWG26 to AWG24
Ferrules with plastic sleeve
0.25 to 0.5 mm
2
AWG24 to AWG20
−
2
Wire end processing
(1) Connecting the wire directly
(a) Twist the end of the stranded wire. Make sure there are no wire whiskers.
(b) Do not solder the wire end.
Approx. 5mm
(2) Using a ferrules with plastic sleeve to connect the wire
A wire with a too thick of a wire sheath may not fit the insulation sleeve.
Refer to the outline drawing for how to select the proper size wire.
Insulation sleeve
Terminal contact section
6mm
2 to 2.5mm
10.5 to 12mm
Manufacturer
Phoenix Contact Inc.
Model name
AI 0.25-6BU (AWG24)
AI 0.34-6TQ (AWG22)
AI 0.5-6WH (AWG20)
Crimper type
CRIMPFOXZA3
3
Tools
Use a small driver with a straight, untapered blade as shown on the right to tighten the power terminals.
Manufacturer
Phoenix Contact Inc.
Model name
SZS 0.4 2.5
0.4mm
Use a driver with a flat end
2.5mm
1
2
3
4
5
6
7
8
7.1 Power Supply Wiring
7.1.1 Cable types and wire end processing (GT1020, GT1030, GT104[ ])
7 - 2
7.1.2
Cable types and wire end processing (GT105
[ ]
)
Use 0.75mm
2
or thicker cables to avoid voltage drop and tighten the terminal screw with the specified torque securely.
1
Electrical wire size, Recommended terminal shape
3.2
Terminal screw
Solderless terminal
Terminal screw
Solderless terminal
6.2mm or less
6.2mm or less
3.2
Cable size
Solderless terminal
When wiring one cable to one terminal
When wiring two cables to one terminal
For power supply: 0.75mm
2
min. For grounding: 2mm
2
min.
M3 solderless terminal :
Recommended applicable solderless terminal
JST Part No. FV0.5-3, Pressure Bonding Tool YHT-2622
JST Part No. FV1.25-B3A, Pressure Bonding Tool YNT-2216
JST Part No. FV2-MS3, Pressure Bonding Tool YNT-1614
7.1.3
Wiring example (GT1020, GT1030)
DC24V
+10%
-15%
Power terminals on the GOT
Class D grounding
Tightening torque for the power terminals 0.22 to 0.25 N•m
7 - 3
7.1 Power Supply Wiring
7.1.2 Cable types and wire end processing (GT105[ ])
7.1.4
Wiring example (GT104
[ ]
)
INPUT
24V DC
DC24V
+10%
-15%
Class D grounding
Tightening torque for the power terminals
7.1.5
Wiring example (GT105
[ ]
)
INPUT
24V DC
DC24V
+10%
-15%
Class D grounding
Tightening torque for the power terminals
0.22 to 0.25 N•m
0.5 to 0.8 N•m
7.1 Power Supply Wiring
7.1.4 Wiring example (GT104[ ])
7 - 4
7
8
5
6
3
4
1
2
7.1.6
GOT’s ground
1
Grounding the GOT and other devices
Make sure to carry out the followings for grounding.
Except 5V power supply type.
• Carry out the independent grounding if possible.
Provide class D (class 3) grounding. (Ground resistance must be 100
Ω or less.)
• If the independent grounding is impossible, carry out the shared grounding as shown in fig.2) below.
GOT
Other device
Grounding
(100 or less)
GOT
Other device
Grounding
(100 or less)
GOT
Other device
(1) Independent ground
...... Best condition
(2) Shared grounding
...... Good condition
(3) Common grounding
...... Not allowed
• Set the grounding point closer to the GOT to make the grounding cable short as possible.
Provide grounding using a single grounding wire. Refer to the table below to select the proper size grounding wire.
(For GT1020, GT1030, GT104 )
Solid wire
1.5mm
2
, AWG16
Ground wire size
Stranded wire
1.0mm
2
, AWG16
Ferrules with plastic sleeve
0.5mm
2
, AWG20
(For GT105 )
Ground wire size
2mm
2
or more
7 - 5
7.1 Power Supply Wiring
7.1.6 GOT’s ground
7.1.7
The cause of malfunctions related wiring/Remedy
Grounding of the GOT may cause electric potential difference and noise interference, which may result in
GOT malfunctions.
These problems may be resolved by taking the following measures.
1
Wiring path of the GOT's ground cable and power line
Bundling the GOT's ground cable and power line together can cause interference noise, which may result in malfunctions.
Keeping the GOT's ground cable and power line away from each other will help minimize noise interference.
FG
MITSUBISHI
GOT
1000
FG
MITSUBISHI
GOT
1000
1
2
3
Power supply for power equipment
Good: Wiring the ground cable away
from the power cable
Power supply for power equipment
Bad: Bundling the ground cable and
the power cable
2
Connecting the ground cable from the panel that houses control equipment to the panel to which the GOT is grounded
When running a single ground cable from the panel that houses such piece of control equipment as a sequencer to the panel to which the GOT is grounded, the ground cable may have to be directly connected to the terminal on the GOT.
MITSUBISHI
GOT
1000
Connection cable
FG
Ground cable from the panel that houses control equipment
4
5
6
If electric potential difference between the ground points created by it causes malfunctions, lowering the voltage as shown in Remedy 1 below may solve the problem.
7
8
7.1 Power Supply Wiring
7.1.7 The cause of malfunctions related wiring/Remedy
7 - 6
• Remedy 1 (Refer to the figures Remedy 1-1 and 1-2 below.)
If the electric potential difference between the ground cable and the panel that houses the GOT is creating problems, connect the ground cable to the panel also.
If the wiring method as shown in Remedy 1-1 is not feasible, follow Remedy 1-2.
MITSUBISHI
GOT
1000
MITSUBISHI
GOT
1000
Connection cable
FG
Connection cable
Ground cable from the panel that houses control equipment
Use the thickest cable possible.
FG
Ground cable from the panel that houses control equipment
Use the thickest cable possible.
Panel grounding
Panel grounding
Remedy1-1
Remedy1-2
If taking Remedy 1 worsens noise interference, taking Remedy 2 may alleviate it.
• Remedy 2 (Refer to the figures Remedy 2-1 and 2-2 below.)
Attach a ferrite core to the cable if noise from the GOT panel has adverse effects on the GOT when
Remedy 1 is taken.
Wind the wire around the ferrite core several times (approx. 3 times), if a ferrite core is used.
If the wiring method as shown in Remedy 2-1 is not feasible, follow Remedy 2-2.
MITSUBISHI
GOT
1000
MITSUBISHI
GOT
1000
Connection cable
FG
Connection cable
Ground cable from the panel that houses control equipment
Use the thickest cable possible.
FG
Ferrite core
Ground cable from the panel that houses control equipment
Use the thickest cable possible.
Panel grounding
Remedy2-1
Ferrite core
Panel grounding
Remedy2-2
7 - 7
7.1 Power Supply Wiring
7.1.7 The cause of malfunctions related wiring/Remedy
7.2 Wiring inside and outside the panel
7.2.1
Wiring inside
Run power lines, servo amplifier drive wires, and communication cables so that they do not cross each other.
Noise interference that is generated by cables that cross each other may cause malfunctions.
Surge suppressors are an effective way to filter out surge noise that is generated from no fuse breakers
(NFB), electromagnetic contactors (MC), relays (RA), solenoid valves, and induction motors.
Refer to the section to follow for surge killers.
7.2.3 Attaching surge killers to control equipment
Uncrossed power lines and communication cables
Crossing power lines and communication cables
Power cable
Power cable
NFB
PLC
GOT connection cable
NFB
PLC
GOT connection cable
PLC I/O wire
PLC
I/O wire
1
2
3
4
MC MC RA
Drive control wire
Terminal block
RA MC MC RA
Drive control wire
Terminal block
RA
5
7.2.2
Outside the panel
To pull the power line and communication cable out of the panel, make two pullout holes away from each other and pull the cables through.
Putting both cables through the same pullout hole will increase noise interference.
Power line
Power line
Connection cable
Connection cable
Pullout hole Pullout hole
Keep the power line and communication cable inside the duct at least 100 mm away from each other.
If that is not possible, the use of a metal separator inside the duct can reduce noise interference.
Power line
Wiring duct Separator
100mm or more
Signal line
Power line Signal line
6
7
8
7.2 Wiring inside and outside the panel
7.2.1 Wiring inside
7 - 8
7.2.3
Attaching surge killers to control equipment
If communication errors happen in synch with the on/off signals from certain control equipment (referred to as "load" hereafter) such as no fuse breakers, electromagnetic contactors, relays, solenoid valves, and induction motors, surge noise interference is suspected.
If this problem happens, keep the ground cable and communication cable away from the load.
If that is not possible, an installation of a surge killer will help reduce noise interference.
Place the surge killer as close to the load as possible.
Remedy for AC inductive load
Keep the ground cable and communication cable away from each other.
Output
C
R
L: Load
AC
Output equipment such as PLC output unit
Remedy for DC inductive load
Keep the ground cable and communication cable away from each other.
Place the surge killer near the load.
Output
Output equipment such as PLC output unit
DC
D L: Load
Place the surge killer near the load.
7 - 9
7.2 Wiring inside and outside the panel
7.2.3 Attaching surge killers to control equipment
8. OPTION
8.1 Protective Sheet
The protective sheet is used to protect the operation surface from damage or dirt when the touch key of GOT display section is operated.
2
1
For the GOT, a protective film is pasted on the display at factory shipment. Remove the film when the installation of the GOT is completed.
8.1.1
Applicable protective sheet
The following protective sheets are applicable for GT10
Product name Model
GT10-20PSGB
GT10-20PSCB
GT10-20PSGW
GT10-20PSCW
GT10-30PSGB
GT10-30PSCB
GT10-30PSGW
Protective sheet
GT10-30PSCW
GT10-40PSGB
GT10-40PSCB
GT10-40PSGW
GT10-40PSCW
GT10-50PSGB
GT10-50PSCB
GT10-50PSGW
GT10-50PSCW
.
3.7” protective sheet
(For GT1020)
Contents
Display section antiglare (Frame: transparent) 5 sheets
Display section clear (Frame: transparent) 5 sheets
Display section antiglare (Frame: white), With a logo 5 sheets
4.5” protective sheet
(For GT1030)
Display section clear (Frame: white), With a logo 5 sheets
Display section antiglare (Frame: transparent) 5 sheets
Display section clear (Frame: transparent) 5 sheets
Display section antiglare (Frame: white), With a logo 5 sheets
4.7" protective sheet
(For GT104 )
Display section clear (Frame: white), With a logo 5 sheets
Display section antiglare (Frame: transparent) 5 sheets
Display section clear (Frame: transparent) 5 sheets
Display section antiglare (Frame: white), With a logo 5 sheets
Display section clear (Frame: white), With a logo 5 sheets
Display section antiglare (Frame: transparent) 5 sheets
5.7” protective sheet
(For GT105 )
Display section clear (Frame: transparent) 5 sheets
Display section antiglare (Frame: white), With a logo 5 sheets
Display section clear (Frame: white), With a logo 5 sheets
Logo (removable) Display section Frame Adhesive part
(back)
Protective film
3
4
5
6
7
Protective Film
8
Release paper
8.1 Protective Sheet
8.1.1 Applicable protective sheet
8 - 1
8.1.2
Installing procedure
1
If a protective sheet is on the GOT, peel off the protective sheet from the bottom-right corner of the GOT display section, and clean the GOT surface.
2
Peel the release paper from the back of the new protective sheet, and attach its adhesive side to the GOT display section.
When attaching the protective sheet, make sure to fit it on the display section closely without leaving any clearance between them.
3
Peel off the protective film on the protective sheet.
Remark
Replacement time of protective sheet
Check the status of the protection sheet visually by to the daily inspection.
The visibility becomes worse when there is too much dirt and cracks, causing malfunction. Proceeds replacement promptly.
8 - 2
8.1 Protective Sheet
8.1.2 Installing procedure
8.2 RS-232/USB conversion adaptor
GT10-RS2TUSB-5S RS-232/USB conversion adaptor is an adaptor that converts the RS-232 interface for communication with PC on the GOT(For GT1020, GT1030) to the USB interface.
It is used with a GT09-C30USB-5P USB cable.
The use of a GT10-RS2TUSB-5S RS-232/USB conversion adaptor requires an installation of the USB driver that is supplied with the package.
GT1020, GT1030
Communication driver
Personal computer
Installing
1
2
3
Conversion adaptor
USB cable for connecting a personal computer
(Mitsubishi Electric System Service Co, LTD)
USB port
+
4
8.2.1
Shape, Dimensions, and Names of Adaptor Components
The shape, dimensions, and names of the RS-232/USB conversion adaptor are shown in the figures below.
Communication connector (for USB connection)
5
6
40(1.57") 200(7.87") 75(2.95")
Display LED (POWER/SD/RD)
Communication connector (for RS-232 connection)
Unit : mm(inch)
Weight : Approx. 40g
Name
Communication connector
(for RS-232 connection)
Specifications
MINI-DIN 6 pins (male):
For connection to the interface for communication with PC on the GOT
Communication connector (for USB connection) USB MINI: For connection to the GT09-C30USB-5P USB cable
Display LED (POWER)
Green : Lit when the power is properly supplied
(Lit when connected to the PC with a USB cable)
Display LED (SD)
Display LED (RD)
Red: Lit while sending data (GOT PC)
Red: Lit while receiving data (PC GOT)
8.2 RS-232/USB conversion adaptor
8.2.1 Shape, Dimensions, and Names of Adaptor Components
8 - 3
7
8
8.2.2
Installing procedure
1
Turn off the GOT power.
2
Connect the USB mini connector on the GT09-C30USB-5P USB cable to the RS-232/USB conversion adaptor.
3
Connect the RS-232 connector on the RS-232/USB conversion adaptor to the GOT.
4
Connect the USB connector on the GT09-C30USB-5P USB cable to the PC.
5
Turn on the GOT power.
6
Turn on the PC power.
7
Confirm that the POWER LED (POWER) on the RS-232/USB conversion adaptor is lit.
(Lit POWER LED on the RS-232/USB conversion adaptor indicates that the power is properly supplied from the PC.)
8 - 4
8.2 RS-232/USB conversion adaptor
8.2.2 Installing procedure
8.2.3
Driver installation
Procedure for installing the driver is explained below.
Windows XP installation follows.
• Windows 98SE, Windows Millennium Edition, and Windows 2000, the installation method will vary.
Installation of the driver is canceled during the following process, the installation is not carried out correctly.
If the installation is canceled, uninstall the driver and install again.
Please refer to Section 8.2.4 for instructions on uninstalling the driver.
Please install the driver with the following procedure.
1
When the USB cable is connected to the personal computer, the following screen is displayed.
(Installation of the software for USB driver)
(For GT Designer2)
1
2
3
4
5
Insert the included CD-ROM into the personal computer's CD-ROM drive.
Click [ Next > ].
The installation of the USB driver software will begin.
• If using Windows 98SE, Windows Millennium Edition, and Windows 2000, a window to select the location of the installation files.
Please select the CD-ROM drive.
2
The following screen is displayed. (Only in Windows XP)
6
7
8
Click [ Continue Anyway ].
8.2 RS-232/USB conversion adaptor
8.2.3 Driver installation
8 - 5
3
The following screen is displayed.
Click [ Finish ].
The installation of the USB driver software will finish.
• If Windows 98SE or Windows Millennium Edition is used, installation of the USB Serial Port software begins, and ends automatically.
The CD-ROM can be removed from the personal computer at this time.
• If using Windows 2000 or Windows XP, proceed to step .
4
The following screen is displayed.
Click [ Next > ].
The installation of the USB Serial Port software will begin.
• If using Windows 2000, a screen to select the location of the installation files is displayed.
Please select the CD-ROM drive.
5
The screen of is displayed. (Only in Windows XP)
Click [ Continue Anyway ].
8 - 6
8.2 RS-232/USB conversion adaptor
8.2.3 Driver installation
6
The following screen is displayed.
3
Click [ Finish ].
The installation of the USB Serial Port software will finish.
The CD-ROM (USB driver software) can be removed from the personal computer at this time.
4
1
2
7
8
5
6
8.2 RS-232/USB conversion adaptor
8.2.3 Driver installation
8 - 7
8.2.4
Method for Uninstalling Driver
The procedure for uninstalling the driver is explained below.
A Windows XP example follows.
When the driver softwares for FX-USB-AW/FX
3U
-USB-BD and GT10-RS2TUSB-5S are installed, uninstalling one of these driver softwares may cause the other not to function properly.
When this happens, reinstall the driver software.
1
Detach the USB cable from the personal computer.
Click [ Start ]
→ [ Control Panel ] → [ Add or Remove Programs ] in the menu of the personal computer, the window below will be displayed.
• In case of Windows 98SE, Windows Millennium Edition, and Windows 2000
A screen that is equivalent to the one below is displayed by clicking [ My Computer ]
→
[ Control Panel ]
→ [ Add/Remove Programs ] in the menu of the personal computer.
Click [ Change/Remove ].
2
The following screen is displayed.
Click [ Continue ].
3
The following screen is displayed.
Click [ Finish ].
8 - 8
8.2 RS-232/USB conversion adaptor
8.2.4 Method for Uninstalling Driver
8.3 Battery
The battery backs up clock data, alarm history and recipe data.
At factory shipment, a battery is built in the GT1030, GT104 , GT105 .
For GT1020, a battery cannot be used. (Data is saved by the internal flash ROM.)
8.3.1
Applicable battery
The following battery is applicable for GT1030, GT104 , GT105 .
Model
GT11-50BAT
Contents
Battery for backup of clock data, alarm history and recipe data
8.3.2
Battery specifications
Item
Type
Initial voltage
Storage life
Application
Specifications
Magnesium manganese dioxide lithium primary battery
3.0V
Approx. 5 years (Operating ambient temperature of 25 )
For backup of clock data, alarm history and recipe data
Remark
For the battery directive in EU member states, refer to 18.4
Handling of
Batteries and Devices with Built-in Batteries in EU Member States.
1
2
3
4
5
6
7
8
8.3 Battery
8.3.1 Applicable battery
8 - 9
8.3.3
Battery replacement procedure
Replace battery periodically at intervals of 4 to 5 years as reference.
1
Turn the GOT power off.
2
Open the back cover of the GOT.
3
Remove the old battery from the holder.
Back cover
Back cover
Back cover
Holder
Connector
Holder
Connector
Connector
For GT1030
For GT104 For GT105
4
Disconnect the old battery connector and insert the new battery connector within 30s.
5
Insert the new battery into the holder and close the back cover.
Back cover
Back cover
Back cover
Holder
Connector
Holder
Connector
Connector
For GT1030 For GT104 For GT105
6
Turn the GOT power on.
7
Check if the battery condition is normal with the utility.
Refer to the following for the details of battery status display.
Chapter 13 CLOCK SETTINGS AND BATTERY STATUS DISPLAY (TIME SETTING
8 - 10
8.3 Battery
8.3.3 Battery replacement procedure
(1) Battery life
The battery life is approximately 5 years.
The production date of the battery built in the purchased GOT can be confirmed by the production No. (serial No.) marked on the GOT main unit.
GRAPHIC OPERATION TERMINAL
MODEL
IN 20.4
GT1030-LBD
26.4VDC POWER 2.2W MAX
SERIAL 710001 AA
MITSUBISHI ELECTRIC CORPORATION
MADE IN JAPAN
JY550D26301A
Year (example: 2007) last digit
7 1 0 0 0 1
Control number
Month (example: Jan.). 1 to 9: Jan. to Sep.,
X: Oct., Y: Nov., Z: Dec.
The production date of the optional replacement battery can be confirmed by the lot No. marked on the nameplate (label) affixed on the battery.
Nameplate
Model name
L OT.5 4
Year (example: 2005) last digit
Month
(example: Apr.)
1 (Jan.) to 9 (Sep.),
X (Oct.), Y (Nov.), Z (Dec.)
GT11-50BAT
LOT.54
Connector
(2) Battery procurement
The battery is susceptible to natural discharge. Order one when necessary.
1
2
3
4
5
6
7
8
8.3 Battery
8.3.3 Battery replacement procedure
8 - 11
8.4 Memory loader
GT10-LDR memory loader is the memory transfer module that reads/writes the data to GT1020, GT1030 or between a PC (GT Designer2 Version2.77F or later, GT Designer3 Version1.01B or later) and GT10-LDR.
When using the memory loader, driver installation, communication port setting is required.
Refer to the following manual for details about driver installation.
GT Designer2 Version Basic Operation/Data Transfer Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
GT1020, GT1030
USB connecting cable (supplied)
PC
*1
(GT Designer2, GT Designer3)
*1: When GT10-LDR is connected to a PC via the USB hub, the power supply of the USB hub must be supplied by the AC adopter of the USB hub.
GT10-LDR connected to the USB hub may not work properly depending on the PC environment. In the case, connect the GT10-LDR directly to the USB port on the PC.
8 - 12
8.4 Memory loader
8.3.3 Battery replacement procedure
8.4.1
Part Name
1) 2) 3) 12) 13)
1
2
10)
11)
6)
4)
5)
3
14)
9)
4
7)
8)
5
No.
1)
2)
3)
4)
5)
6)
Name
POWER LED
SET/RUN LED
ERROR LED
RD/WR selection switch
Data selection switch
ENT key
7)
8)
9)
Write protection switch
USB port
Reference plate
(operating instructions)
10)
Reference plate
(error contents)
11) Transfer cable
12) Strap hole
13) Part to be labeled
14) Rating plate (Nameplate)
Specifications
LED to show power status
LED to show that the settings are being checked/the transfer is running
LED to show error status
Switch to select read/write direction
Switch to select the data to be transferred
Switch to determine the transfer direction and the data to be transferred, and to start the transfer
Switch to prevent the memory loader from being written to the data
Connection port with a PC (with protection cap)
Described operating instructions of tne memory loader
Described lighting status of ERROR LED
Cable to be connected with the GOT
A hole to attach a strap
Space to be labeled (created by user)
--
6
7
8
8.4 Memory loader
8.4.1 Part Name
8 - 13
8.4.2
Function specification
1) Standard monitor OS
Font data
Communication driver
Project data
3) Standard monitor OS
Font data
Communication driver
Project data
2) Project data
Resource data
4) Standard monitor OS
Communication driver
Project data
Resource data
GT1020, GT1030
PC
(GT Designer2, GT Designer3)
Memory loader
Transfer direction loader
2) Memory loader
PC
3) Memory loader
GOT loader
Data selection switch
--
--
PROJECT
+ OS
PROJECT
PROJECT
+ OS
*1
PROJECT
Project data
Resource
data
: Available to transfer : Unavailable to transfer
Transfer data
Standard
monitor OS
Font data
*2
Communication driver
Operation
After all data in the memory loader is deleted, the data selected with GT
Designer2 or GT
Designer3 is written to the memory loader all at once.
The project data or resource data is read out from the memory loader to a PC
All data in the memory loader is written to the
GOT.
Only the project data in the memory loader is written to the GOT.
After all data in the memory loader is deleted, all data in the
GOT is read out to the memory loader.
After all data in the memory loader is deleted, only the project data and resource data in the
GOT are read out to the memory loader.
*1 : Ver.01.08.00 or later of the standard monitor OS of the GT10 is applicable.
GT10-LDR Memory loader USER’S MANUAL (Chapter 7 Function specification)
8 - 14
8.4 Memory loader
8.4.2 Function specification
*2 : Ver.01.11.00 or later of the standard monitor OS of the GT10 is applicable.
Supported by the memory loader manufactured in November 2008 or later.
When transferring the font data with the memory loader manufactured before November 2008, upgrade the version of memory loader OS from GT Designer2 (Ver.2.91V or later).
For the OS installation to the memory loader, refer to the following.
GT Designer2 Version Basic Operation/Data Transfer Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
1
2
(1) When transferring the font data from the memory loader to the GOT
When transferring the font data from the memory loader to the GOT, it takes more time than transferring only the standard monitor OS and communication driver.
• It takes approximately 1 minute and 45 seconds to transfer "Standard monitor OS + Communication driver".
• It takes approximately 8 minutes and 10 seconds to transfer "Standard monitor OS + Communication driver + Font data". (GT1030)
Japanese (supporting Europe) is installed in the GT10 before shipment from the factory.
It is not necessary to transfer the font data when the used font is not changed.
(2) How to check the manufacturing date of the memory loader
The manufacturing date of the memory loader can be checked with the SERIAL
No. on the memory loader.
3
4
5
Year (example:2007) last digit
Control number
Month (example : Jan.). 1 to 9: Jan. to Sep.,
X: Oct., Y: Nov., Z: Dec.
6
7
8
8.4 Memory loader
8.4.2 Function specification
8 - 15
8.5 Memory board
GT10-50FMB type memory board is used for transferring the OS, project data or font data to the GOT (for
GT104 , GT105 only).
8.5.1
Applicable memory board
The following memory board is applicable for GT104 , GT105 .
Model
GT10-50FMB
Contents
For transferring project data, the OS or font data
8.5.2
Installing and removing procedures of the memory board
1
Inrtallation
1
Turn the GOT power off.
2
Remove the memory board cover.
Memory board cover
Memory board cover
For GT104
3
Set to OFF the protection switch in the memory board.
For GT105
4
Mount the memory board to the memory board connector on the GOT rear face.
Memory board
Memory board
For GT104
5
Turn the GOT power on.
6
Make the setting for transferring the data with the utility.
Refer to the following for detailes.
8 - 16
8.5 Memory board
8.5.1 Applicable memory board
For GT105
1
2
Removing
1
Turn the GOT power off.
2
Pull up the memory board vertically and remove it.
Memory board
Memory board
2
3
For GT104
For GT105
Precautions for installing/removing the memory board
When installing or removing the memory board, be sure to power off the GOT main unit.
Install the memory board cover when not using the memory board.
4
5
6
7
8
8.5 Memory board
8.5.2 Installing and removing procedures of the memory board
8 - 17
8.6 Stand
Stand is used to fix the GOT (For GT105 ) to standing status in order to debug the monitor screen data easily.
8.6.1
Applicable stand
The following stand is applicable for GT105 .
Product name
Stand
Model
GT05-50STAND
Contents
Stand for 5.7" (For GOT1000 Series)
8.6.2
Installing procedure
1
Adjust the mounting angle of GOT with the angle adjusting fitting of the stand.
Adjust to
45 , 55 , 65 or 75 .
Angle adjusting fitting
2
Put the GOT into the stand from the stand front side and fix it using the fixtures.
For how to mount the GOT, refer to the following.
Section 6.5 Installation Procedure
For details of the stand, refer to the following.
GT05-50STAND
GOT1000 Series Stand User's Manual
GOT mounting face
8 - 18
8.6 Stand
8.6.1 Applicable stand
8.7 Protective cover for oil
Use of the protective cover for oil improves waterproof property, oil resistance, and chemical resistance of the GOT (For GT105 ).
8.7.1
Applicable protective cover for oil
The following protective covers for oil are applicable to the GT105 .
Product name
Protective cover for oil
Model
GT05-50PCO For 5.7" GOT
Description
8.7.2
Installing procedure
1
2
3
Before attaching protective cover for oil
For attaching the protective cover for oil to the GOT already mounted on the control panel, follow the procedures as below.
• Remove the GOT from the control panel. Make sure to externally shut off all phases of the power supply and remove all cables from the GOT in advance.
• Clean dirt off surfaces of the GOT and control panel.
1
Check that the rubber packing is installed on the GOT rear face, and then fit the protective cover for oil to each corner of the GOT front face.
Position the POWER LED frame of the cover to the
POWER LED on the GOT front face.
Fit the cover to each GOT corner.
4
5
6
2
Spread the protective cover for oil so that it covers the rubber packing part on the GOT rear face.
For keeping liquids and others out of the control panel, make sure that the rubber packing part is completely covered.
Make sure that corners of protective cover for oil match those of GOT front.
7
8
8.7 Protective cover for oil
8.7.1 Applicable protective cover for oil
8 - 19
3
Mount the GOT onto the control panel.
When the control panel is dirty, clean the control panel.
The panel cutting dimensions and mounting screw tightening torque with the protective cover for oil are the same as those without the cover.
Mount the GOT onto the control panel by referring to
Protectivecover for oil
Panel cut dimensions
Mounting metal fixture
Control panel
Precautions for protective cover for oil
• The protective cover for oil is consumable product.
Check the cover for scratch, damage or dirt at regular intervals, and replace with new one if necessary.
• Do not push the protective cover for oil with pointed tools, including mechanical pencils and screwdrivers.
Doing so causes scraches and damages of the cover.
• Do not clean the protective cover for oil with bleaches, thinners, organic solvents, corrosive chemicals, and others. Doing so causes changes in shape and color of the cover.
• When the protective cover for oil is attached to the GOT, do not stretch and bend the cover too much.
Doing so may cause a separation between the sheet and rubber.
• Do not place or use the protective cover for oil in direct sunshine.
• When the protective cover for oil gets dusts, wipe the dusts off with a damp cloth.
8 - 20
8.7 Protective cover for oil
8.7.2 Installing procedure
8.8 Serial Multi-Drop Connection Unit
8.8.1
Serial multi-drop connection unit
GOT multi-drop connection is a communication method for 1:N communication by connecting multiple GOTs to one PLC, using the GT01-RS4-M serial multi-drop connection module.
For details of GOT multidrop connection, refer to the following.
GOT1000 Series Connection Manual
1
2
3
• Communication driver
• Communication interface
Serial multi drop connection module
Connect to the PLC.
• GT Designer2
• GT Designer3
• Communication driver
• Communication interface
4
Varies according to the connection type.
RS-485 cable
MAX500m
5
(1) GOTs supporting the GOT multi-drop connection
The followings are the GOTs compatible with the GOT multi-drop connection.
Standard monitor OS GOT
GT1055-QSBD, GT1050-QBBD
GT1045-QSBD, GT1040-QBBD
GT1030-LBD/LWD, GT1030-LBDW/LWDW
GT1020-LBD/LWD, GT1020-LBDW/LWDW
Hardware version
Version C or later
Version A or later
Version B or later
Version E or later
Standard monitor OS[01.12.**]
(2) Checking method of hardware version
Confim the hardware version with the products rating plate.
6
7
GRAPHIC OPERATION TERMINAL
MODEL
GT1030-LBD
IN 20.4 26.4VDC
POWER 2.2W MAX
SERIAL 710001 AA
MITSUBISHI ELECTRIC CORPORATION
MADE IN JAPAN
JY550D26301A
AA
Hardware version
8
8.8 Serial Multi-Drop Connection Unit
8.8.1 Serial multi-drop connection unit
8 - 21
8.8.2
Applicable serial multi-drop connection unit
The following serial multi-drop connection unit is applicable.
Model
GT01-RS4-M
Contents
For GOT multi-drop connection
8.8.3
Part name
1)
• Protective cover is installed
2)
• Protective cover is removed
5)
4)
3)
7)
6)
2- 4.5
57
65
9)
10)
12)
11)
8)
8 - 22
No.
Name
1) Installation hole for the main unit
POWER
SD
2) LED
RD
ERROR
3) Terminating resistor selector
4) Connector for PLC communication
5)
Connector selection switch for PLC communication
6) USB port
7) Connector for PLC communication
8) Protective cover
9)
Terminal block for the serial multi-drop communication
10) Power supply connector
11) Slider for installing the DIN rail
12)
Mode selection switch
(Slide switch)
Specifications
Installation hole
Lit in green when the power is properly supplied.
Lit in green when the data is being sent to PLC.
Lit in green when the data is being received from PLC.
Lit or blinking depending on the status.
Can be selected among 110 , OPEN and 330
(set to "OPEN" by default)
D-sub 9-pin (male) For RS-232 connection
Switch for selecting RS-422 or RS-232 (set to "RS-422" by default)
For connecting to a personal computer (for changing the communication driver)
D-sub 9-pin (female) For RS-422 connection
Protect unused D-sub connector, USB port and switches.
Terminal block 5-pin (with a protective cover) M3 Tightening torque
0.5 to 0.6N.m
24VDC power supply connector insertion point (A dedicated cable is included.)
−
Do not operate. (Set to right by default. When set to left, the module does not operate normally.)
8.8 Serial Multi-Drop Connection Unit
8.8.2 Applicable serial multi-drop connection unit
8.8.4
Installation
1
1
Installed with DIN rail
Install the multi-drop connection module with its hook (1 place) using the DIN rail.
• Applicable DIN rail DIN46277 (width: 35mm)
(Install the DIN rail with screws at intervals of 150mm.)
2
Directly installed to panel
Install the multi-drop connection module to the panel using 4.5mm holes (2 places).
8.8.5
Caution for compliance with EMC Directive
Programmable logic controllers are open-type devices that must be installed and used within conductive control boxes. Please use the Multi-Drop Connection Unit while installed in conductive shielded control boxes. Please secure the control box lid to the control box (for conduction). Installation within a control box greatly affects the safety of the system and aids in shielding noise from the Multi-Drop Connection Unit.
2
3
4
5
6
7
8
8.8 Serial Multi-Drop Connection Unit
8.8.4 Installation
8 - 23
8.9 Connector Conversion Adapter
GT10-9PT5S type connector conversion adapter enables an easy crossover wiring for the multi-dropconnected GOTs.
For the wiring between the connector conversion adapter and the controller, refer to the following manual.
GOT1000 Series Connection Manual
(1) GOTs supporting the connector conversion adapter
The followings are the GOTs compatible with the connector conversion adapter.
Standard monitor OS GOT
GT1055-QSBD, GT1050-QBBD
GT1045-QSBD, GT1040-QBBD
Hardware version
Version C or later
Version A or later
Standard monitor OS[01.12.**]
(2) Checking method of hardware version
Confim the hardware version with the products rating plate.
GRAPHIC OPERATION TERMINAL
MODEL
GT1030-LBD
IN 20.4 26.4VDC
POWER 2.2W MAX
SERIAL
710001 AA
MITSUBISHI ELECTRIC CORPORATION
MADE IN JAPAN
JY550D26301A
8.9.1
Applicable connector conversion adapter
AA
Hardware version
The following connector conversion adapter is applicable.
Model
GT10-9PT5S
Contents
For GOT multi-drop connection
8.9.2
Installing procedure
1
Turn the GOT power off.
2
Connect the connection conversion adapter to the RS-422/485 interface on the GOT.
3
Fix the connection conversion adapter to the GOT using the provided M3 tapping screws.
4
Tightening torque: 0.3 to 0.6N m
8 - 24
8.9 Connector Conversion Adapter
8.9.1 Applicable connector conversion adapter
9. UTILITY FUNCTION
The utility functions allow the user to confirm the settings for communication interface, screen display, operation methods, and clock data as well as OS information.
GT10 is factory-installed with the Standard monitor OS and BootOS.
(An installation of the Standard monitor OS or BootOS is not required to use the utility functions.)
10
9.1 Utility Function List
The items in the following list can be set/operated on the utility screens.
Language
Standard I/F
Communication monitor
Keyword
Contrast
Brightness
Opening time
Backlight
Functions overview
Data transfer
Screen save
Item
Time
GT1020 GT1030
GT104 GT105
Switches the display language for the utility functions (Japanese/English)
Displays the detailed information about the communication method and communication driver
Displays the screen for transferring project data between the PC and GOT
(If any device other than the PC is allocated to the interface for communication with PC, the
GOT will not be able to communicate with the PC, except when the Data transfer window is on the screen.)
Displays the communication status of each communication port
Sets a keyword of the FX series PLC.
Sets the screensaver activation time (from the last time the screen was touched)
Setting range: 0 to 60 min. (Screensaver is disabled when it is set to 0 minute.)
Default : 0 min.
This setting is used to decide whether to turn the backlight on or off when the screensaver comes on
Default : OFF
Adjusts the contrast on the liquid crystal display (16 level adjustment, 0 to 15)
-
Adjusts the intensity on the liquid crystal display (8 level adjustment, 0 to 7)
The title display period at the main unit boot can be set. (0 to 60 sec)
Default : 5 sec
-
Buzzer volume
Changes the buzzer settings (OFF/SHORT/LONG)
Default : SHORT
Buzzer setting
Window move buzzer
Whether turn ON/OFF buzzer when move window can be selected
Default : ON
Calibration
Calibrates the touch panel sensitivity
-
Security
*1
Utility call
Key reaction
Security level change (security password input of each object)
Setting of the menu call key
Clock setting
Display of key reaction speed
Setup the method to adjust the time between GOT clock data and clock data of PLC CPU connected with GOT
(Continued to next page)
11
12
13
14
15
16
9.1 Utility Function List
9 - 1
9
Time setting
Data
Item
Clear data
GT10-50FMB
GT1020
Functions overview
GT1030
GT104 GT105
Sets the clock (clock data) on the PLC
Sets the clock (clock data) on the PLC, Display of battery status
OS information
Displays the OS (Standard monitor OS, BootOS) and communication driver versions
Clears the project data and resource data on the GOT
-
Datas are transferred between the memory boards.
Device monitor
Device monitor of PLC of intelligent module
Debug
FX list editor -
The sequence program of FX PLC can be list edited
Clean
Display the screen to clean the display section
*1: It is necessary to set the security level with drawing software.
9 - 2
9.1 Utility Function List
9.2 Utility Display
9.2.1
Display operation of main menu
The following three types of operation can display the main menu.
(The utility function windows appear in the horizontal format, and this format cannot be changed.)
(1) When project data is undownloaded
After the GOT is turned on, a dialog box for notifying of absence of project data is displayed.
After the dialog box is displayed, touch the
OK
button to display the main menu.
GOT power on
Touch the OK button
9
10
11
(2) When touching menu call key
If you touch the menu call key while user-created screen is displayed, the main menu is displayed.
The menu call key can be set with the GOT utility screen or drawing software.
(At factory shipment, menu call key position it is set in the top left corner of the GOT screen on the
GT1020.)
(At factory shipment, menu call key is set to “Simultaneous 2 - point presses on GOT screen upper
- right and upper - left corners“ on the GT1030, GT104 or GT105 .)
Menu call key
(1-point touch on GOT screen upper-right corner)
12
13
For GT1020
14
Menu call key
(Simultaneous 2-point touch)
15
For GT1030,
GT104 , GT105
16
9.2 Utility Display
9.2.1 Display operation of main menu
9 - 3
(3) When touching special function switch
If you touch the special function switch (utility) while user-created screen is displayed, the main menu is displayed.
The special function switch (utility) can be set as a touch switch that is displayed on a user-created screen by drawing software.
(When the utilities menu is assigned to the special function switch, the main menu appears when the switch is touched.)
Special function switch (Utility)
For the details of the special function switch, refer to the following.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Functions)
Remark
Lock the utility display by password.
When a password is set on the GOT using drawing software, a password dialog box is displayed when trying to access the main menu of the utility display.
(The password setting option in drawing software is located in the common menu.)
Enter the password that has been set.
(1) Input operation of password
1) Input the password after touching
0
to
9
,
A
to
F
key.
2) Define the password by touching
Enter
key, after inputting password.
3) To correct the input character, touch
Del
key to delete the correcting character and then reinput/retype the new character.
(2) Password input cancel operation
When
ESC
button is touched, the screen returns to the monitor screen.
Refer to the following for details on setting passwords.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Functions)
(3) If an invalid password is entered
If an invalid password is entered, the error message will appear.
Touching the
OK
button will take the screen back to the monitor screen.
9 - 4
9.2 Utility Display
9.2.1 Display operation of main menu
9
When starting the GOT without selecting any language (At factory shipment)
The following screen will be displayed at the initial startup of GOT.
Touching the button of a desired language restarts the GOT and the language is switched to the selected one.
10
11
12
15
16
13
14
9.2 Utility Display
9.2.1 Display operation of main menu
9 - 5
9.2.2
Utility basic configuration
The basic configuration of the screen is as follows.
1
Main Menu
The menu items that can be selected from the GOT utility are displayed.
GT1020 GT104 , GT105
1
Use the , buttons to select an item from the menu.
2
Touching a menu item in the main menu will display the setting screen or following selection screen for the item.
3
Touching the
ESC
button will take the screen back to the user screen.
9 - 6
9.2 Utility Display
9.2.2 Utility basic configuration
GT1020
Title display Close/Return button
GT104 , GT105
Title display Close/Return button
9
Scroll button
10
Menu item
11
Main item Scroll button
(1) Title display
The screen title name is displayed in title display part.
(2) Close/Return button
When a middle screen of the layers is displayed, if the
ESC corner of screen is touched, returns to the previous screen.
(Close/return) button in the right
If this button is touched when directly displayed from monitor screen, the screen is closed and returns to monitor screen.
(3) Scroll button
For screens in which the content does not fit on one screen page, there is a right or down scroll button on the screen.
Scroll one line/window
12
13
14
15
16
9.2 Utility Display
9.2.2 Utility basic configuration
9 - 7
10. LANGUAGE SETTING (Language)
10.1 Display language setting
10.1.1 Display language setting function
This function allows display language selection.
The items which can be set are shown below.
Item
Language
Contents
Display language in which the utility functions and dialog windows are displayed can be selected or confirmed in this menu
Setting range
Japanese/English
<At factory shipment: Japanese>
10.1.2 Language display operation
Main Menu
Touch [Language].
10.1.3 Language setting operation
1
Language
Main Menu
Touch [Language].
1
Touch [Language] to bring up the set up screen.
2
Select a display language by touching the corresponding button.
Touch a language to be displayed.
3
Touch the
ESC
button to save the setting and close the window.
Touch
10 - 1
10.1 Display language setting
10.1.1 Display language setting function
11. COMMUNICATION INTERFACE
SETTING
(COMMUNICATION SETTING)
10
The [Communication Setting] menu has the [Standard I/F], [Data Transfer], [Communication Monitor], and
[Keyword] menus.
The [Standard I/F] menu sets the information about the channel numbers, controller name, and detailed settings of the communication parameters that are allocated to the communication interfaces by drawing software.
The [Data Transfer] menu displays the screen for transferring project data between the PC and GOT.
The [Communication Monitor] menu displays the communication status of each communication port.
The [Keyword] menu registers, deletes, clears, and protects a keyword of the FX series PLC.
11.1 Standard I/F Setting
11.1.1 Standard I/F functions
11
12
9
Function
Channel no. display
Communication driver display
Communication parameters display
Contents
Displays the channel number (CH No) that has been assigned by drawing software
Displays the communication driver that has been assigned by drawing software
Displays the communication parameters of the controllers that has been assigned by drawing software
11.1.2 Standard I/F display operation
13
14
Main Menu
Touch [Standard I/F].
Touch [Comm. Setting].
15
Standard I/F
16
11.1 Standard I/F Setting
11.1.1 Standard I/F functions
11 - 1
11.1.3 Display contents of standard I/F
Described below are the display items on the standard I/F setting menu and their functions.
1
Display item column
<For GT1020>
Communication interface selection button
<For GT1030>
Drv button
AT button
Channel No. specification menu BOX
Standard interface display BOX
Driver display BOX
Channel No. specification menu BOX
Drv button
AT button
Channel No. specification menu BOX
<For GT104 , GT105 >
Standard interface display BOX
Driver display BOX
Drv button
AT button
(1) Communication interface selection button <For GT1020>
Select the communication interface to be displayed.
Touch Standard I/F-1 .
Touch Standard I/F-2 .
11 - 2
11.1 Standard I/F Setting
11.1.3 Display contents of standard I/F
(2) Standard interface display BOX
Displays communication interface.
(a) GT1020, GT1030
The standard interface includes the following two types.
Standard I/F-1: For communication with PLC, microcomputer and other equipment
Standard I/F-2: For communication with PC (drawing software), modem, bar code reader and transparent
Standard I/F-1 Standard I/F-2
9
10
RS-422
SDA
SDB
RDA
RDB
SG
RSA
RSB
CSA
CSB
+
-
INPUT
24VDC
(FG)
RS-232
11
12
Whether an RS-422 or an RS-232 interface (Standard I/F-1) for communication with PLC is used depends on the GOT model.
• GT1020-LBD/LWD/LBL/LWL/LBDW/LWDW/LBLW/LWLW,
GT1030-LBD/LWD/LBL/LWL/LBDW/LWDW/LBLW/LWLW: RS-422 fixed
• GT1020-LBD2/LWD2/LBDW2/LWDW2, GT1030-LBD2/LWD2/LBDW2/LWDW2: RS-232 fixed
13
The type of the interface (Standard I/F-2) for connection to PC is always RS-232.
(b) GT104
The standard interface includes the following three types.
Standard I/F-1(RS-422): For communication with PLC, microcomputer and other equipment
Standard I/F-2(RS-232): For communication with PLC, PC (drawing software), modem, other equipment, bar code reader and transparent
Standard I/F-3(USB): For communication with PC (drawing software) and transparent
14
15
Standard I/F-3 (USB)
Standard I/F-1 (RS-422)
Standard I/F-2 (RS-232)
11.1 Standard I/F Setting
11.1.3 Display contents of standard I/F
11 - 3
16
(c) GT105
The standard interface includes the following three types.
Standard I/F-1(RS-422): For communication with PLC, microcomputer and other equipment
Standard I/F-2(RS-232): For communication with PLC, PC (drawing software), modem, other equipment, bar code reader and transparent
Standard I/F-3(USB): For communication with PC (drawing software) and transparent
[GOT back panel]
Standard I/F-3 (USB)
Standard I/F-1 (RS-422)
Standard I/F-2 (RS-232)
(3) Channel No. specification menu BOX
0: Set when the communication interface is not used.
1: Set when connecting to PLC or microcomputer.
(For GT1020 and GT1030, settable only for the interface (Standard I/F-1) for communication with PLC)
(For GT104 , GT105 , either of standard I/F-1 or standard I/F2 can be set.)
8: Set when connecting to bar code reader.
9: Set when connecting to PC (drawing software), modem. (For standard I/F-2 and standard I/F-
3, the simultaneous setting is possible. However, when either interface is communicating, the communication is not allowed for another interface.)
• Setting is not allowed for 2 to 7, *.
• Fixed to 9 for the USB interface.
(4) Driver display BOX
The name of the communication driver for which a channel number is assigned is displayed.
"None" is displayed in the driver display box in the following cases :
• The communication driver is not installed. (
• "0" is set in the channel number specification menu box.
[*****] will appear when the communication driver that was installed on the GOT from drawing software and the controller setting that was downloaded on to the GOT from drawing software do not match.
When setting the channel number to "9", the communication driver "Host (PC)" is automatically assigned.
When the driver display box is touched, the screen jumps to the detail information screen and the communication parameter appears.
11 - 4
11.1 Standard I/F Setting
11.1.3 Display contents of standard I/F
(5)
Drv
button
Displays the driver setting screen.
Select the driver to use on the driver setting screen.
Drv
button is displayed in the following cases.
• When setting the "ch9" to standard I/F-2.
(6)
AT
button
Displays the AT command setting screen.
Set the AT command to use for initializing the modem on the AT command setting screen.
AT
button is displayed in the following case.
• When "ch9 Host (Modem)" is set to standard I/F-2.
9
10
11
12
13
14
15
16
11.1 Standard I/F Setting
11.1.3 Display contents of standard I/F
11 - 5
11.1.4 Detail information setting operation
1
Touch Standard I/F-1 driver display box in the Standard I/F setting window.
Touch [Driver display BOX].
2
The screen jumps to the detailed information screen and the communication parameter will appear.
Use the , buttons to toggle through the items when there are multiple items to be set.
(The , buttons will not work when no other items are available.)
3
Touch the numerical values of baud rate to switch them repeatedly.
Ex. 4800bps 9600bps 19200bps
The numerical values are set using the ten-key depending on the setting.
“0” to “9” : Use these keys to enter numerical values. Enter "0" to disable the screensaver function
“ESC” : Closes the ten-key window without saving any value entered
“AC” : Deletes the entire string of numerical characters that are being entered
“DEL” : Deletes a digit from a string of numerical characters that are being entered
“ENT” : Enters the value for the clock that has been entered and closes the ten-key pad window
“+ / -” : Switches between positive and negative values (Only positive values are valid for the clock setting.)
“ . ” : Invalid key (not used)
11 - 6
11.1 Standard I/F Setting
11.1.4 Detail information setting operation
4
When the
ESC
button is touched, the settings are fixed and the window returns to the previous one. Therefore, touch the
ESC
button.
5
Touch the
ESC
button to display the window confirming whether to save the settings.
9
10
6
Touch the
YES
button to save the settings and restart.
Touch the changes.
NO
button to discard the
The types of items that are in the communication parameter setting menu depend on the type of communication driver that is installed on the GOT in use.
Refer to the section below for the setting contents of various drivers.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
11
12
13
14
15
16
11.1 Standard I/F Setting
11.1.4 Detail information setting operation
11 - 7
Precautions for communication between GOT and connected devices
(1) Installing [Communication driver] and downloading [Communication Settings]
To perform communication with the connected device, the following actions are necessary.
1) Installing [Communication driver] (Up to 1, OS installation)
The driver for [MELSEC-FX] is factory-installed. Install the communication driver to connect a controller other than a MELSEC-FX.
2) Assigning channel number and communication driver to communication interface (Communication Setting)
3) Downloading [Communication Settings] (project data) assigned in step 2)
Perform 1), 2) and 3) with drawing software.
To change the communication parameter setting after downloading project data, change the setting at drawing software again.
For [Communication Settings], refer to the following manual.
GT Designer 2 Version Screen Design Manual
GT Designer 3 Version Screen Design Manual (Fundamentals)
For installation of [Communication driver] (OS) and download of project data, refer to the following manual.
GT Designer 2 Version Basic Operation/Data Transfer Manual
GT Designer 3 Version Screen Design Manual (Fundamentals)
(2) When [Communication Settings] has not been downloaded using drawing software
When [Communication Settings] has not been downloaded, the GOT automatically assigns the installed communication driver as the standard I/F-1.
When assigning the communication driver to Standard I/F-2 on GT104 ,
GT105 , make the setting in the communication settings of drawing software or in the communication settings of the utility.
11 - 8
11.1 Standard I/F Setting
11.1.4 Detail information setting operation
11.1.5 Channel setting operation
1
Channel number setting operation
9
1
Touch the channel No. specification menu box to be set.
10
Touch
2
When the channel setting window appears, select the channel number.
11
Touch
3
When the channel number is selected, the settings are fixed and the window returns to the previous one. Therefore, touch the
ESC
button.
4
Touch the
ESC
button to display the window confirming whether to save the settings.
12
13
5
Touch the
YES
button to save the settings and restart.
Touch the changes.
NO
button to discard the
14
Channel number
(1) Only channel number 1 is displayed on the standard I/F-1 of GT1020 or GT1030.
(2) Channel number 8 and 9 are displayed on the standard I/F-2 of GT1020 or
GT1030.
15
16
11.1 Standard I/F Setting
11.1.5 Channel setting operation
11 - 9
11.1.6 Driver setting operation
1
Driver setting operation
1
Touch
Drv
button to bring up the driver setting window.
Touch [Drv]
Touch
Touch
2
The available driver names are displayed on the driver setting screen. Select the driver to use.
3
When the driver is selected, the display returns to the standard IF setting screen.
11 - 10
11.1 Standard I/F Setting
11.1.6 Driver setting operation
11.1.7 AT command operation
1
AT command operation
9
1
Touch
AT
button to bring up the AT command setting window.
10
Touch Touch
Touch
Touch [AT]
Touch
2
The AT command, set in the drawing software or in the utility of the main unit, is displayed.
When editing the AT command, touch
SET
button to display the ASCII window.
Input the AT command in the ASCII window.
3
Touch following buttons as necessary.
•
•
INIT
button: Outputs the AT command to the modem.
OFF
button: Disconnects the line.
11
12
13
4
After settings are completed, touch button to close the setting screen.
ESC
14
15
16
11.1 Standard I/F Setting
11.1.7 AT command operation
11 - 11
11.1.8 Installing of communication driver
GT10 is factory-installed with the driver for MELSEC-FX.
An installation of the communication driver is required when connected to a controller other than a MELSEC-FX.
When installing the communication driver, first bring up the OS installation screen on the GOT, and then install the communication driver from drawing software.
Bringing up the OS installation screen
Turn the GOT power on with the lower right corner touched.
Refer to the chapter below for detailed information on the OS installation screen of the GOT.
About the OS installation screen
The OS can be transferred from GT Designer2 or GT Designer3 without displaying the OS installation screen depending on the combination of the GOT and the standard monitor OS.
GT Designer2 GT Designer3 Model BootOS version Standard monitor OS
GT1020 BootOS version F or later
Standard monitor OS
GT1030 BootOS version F or later
[01.08.00]
Version2.77F or later
From the first version
GT104
From the first version Version2.90U or later
GT105
From the first version Version2.90U or later
Refer to the chapter below for how to install the communication driver from drawing software.
GT Designer 2 Version Basic Operation/Data Transfer Manual
GT Designer 3 Version Screen Design Manual (Fundamentals)
Checking method of BootOS, Standard monitor OS version
1. Check the version of BootOS or Standard monitor OS installed in GOT at [OS information] of the utility.
Refer to the following for details.
2. Check the version of BootOS installed in GOT at product shipment on the rating plate on GOT rear face.
GRAPHIC OPERATION TERMINAL
MODEL
GT1030-LBD
IN 20.4 26.4VDC POWER 2.2W MAX
SERIAL 710001 AA
MITSUBISHI ELECTRIC CORPORATION
MADE IN JAPAN
JY550D26301A
AA
BootOS Version
11 - 12
11.1 Standard I/F Setting
11.1.8 Installing of communication driver
11.2 Data Transfer
11.2.1 Data transfer functions
Function
Data transfer screen display
9
Contents
Displays the screen for transferring project data between the PC and GOT.
If any device other than the PC is allocated to the interface for communication with PC, the GOT will not be able to communicate with the PC, except when the
Data transfer window is on the screen.
10
11.2.2 Data transfer operation
11
1
Display from the utility main menu
Main Menu
12
Touch [Comm. Setting].
Touch [Data Transfer].
13
Data Transfer
14
2
Display from the select mode
If data transfer screen cannot be displayed on the user-created screen, power ON to perform select mode while pressing and holding the upper left corner of the screen.
The selection screen of [Normal] or [PC Transfer] appears at the startup.
In the [Normal], an initial screen appears when the monitor screen has been created, and the utility main menu appears when the monitor screen has not been created.
[Data Transfer] screen appears in the [PC Transfer].
Standard I/F-2 is used in the communication mode to the PC.
Bringing up the select mode screen
15
16
Turn the GOT power on with the upper left corner touched.
11.2 Data Transfer
11.2.1 Data transfer functions
11 - 13
11.2.3 Data transfer display
[Waiting] on the data transfer screen will change to [Transferring...] when project data are transferred from drawing software.
At the completion of data transfer, the user-created screen will appear.
Transfer of project data from drawing software
Completion of data transfer
User-created screen
Transfer of project data
If [ESC] button on the display screen is pushed during transfer of project data, transmission of project data is stopped.
In that case, project data are transfered from drawing software again.
11 - 14
11.2 Data Transfer
11.2.3 Data transfer display
11.3 Communication Monitor
11.3.1 Communication Monitor functions
Function Contents
Communication port-selection status display
Communication status display
Displays the connection status of Standard I/F-1 and I/F-2
Displays the communication status (SD: send, RD: receive)
Communication error status display Displays an error message when a communication error occurs
11.3.2 Communication Monitor display operation
Main Menu
Touch .
Touch [Comm. Setting].
Communication Monitor
9
10
11
12
13
Touch [Comm. Monitor].
14
Communication Monitor
(When bar code is connected)
15
16
11.3 Communication Monitor
11.3.1 Communication Monitor functions
11 - 15
11.3.3 Screen display content
2)
1)
3)
1) Connection status of the communication ports
Indicates the connection status of Standard I/F-1 and I/F-2.
Listed in the table below are display items and the connection status (channel number).
Display item Channel number
PLC
BCR
Ch1
Ch8
TRANS.
PC
Ch9
Ch9
Remarks
"PLC" appears when connected to a controller (PLC or microcomputer)
"BCR" appears when connected to a bar code reader
"TRANS." appears when the controller that is allocated to one of the communication ports supports the transparent mode
"TRANS." automatically changes to "PC" when communicating with drawing software
"PC" appears when the controller that is allocated to one of the communication ports does not support the transparent mode
2) Communication status
Communication status of each communication port is displayed on this screen.
The SD and RD symbols appear in black on white (
SD
,
RD
) while data are being sent or received, and in white on black ( communication status.
SD
,
RD
) at other times. They may appear lit depending on the
The SD and RD symbols on the screen indicate normal communication or cable disconnection.
Port
I/F-1
IF-2
Channel number Controller type
Ch1
Ch8, Ch9
MELSEC-FX
−
[During normal communication (with connection to a device that supports the transparent mode)]
The SD and RD symbols for both I/F-1 and I/F-2 blink.
[When the connecting cable with the controller is disconnected]
Only the SD symbol next to I/F-1 blinks.
11 - 16
11.3 Communication Monitor
11.3.3 Screen display content
3) Communication error status
Communication error status of each port is displayed on this screen.
The table below summarizes the types and nature of the errors.
Display item
NO ERROR
ERR Ovr.
ERR Frm.
ERR Prt.
ERR Text
TIME OUT
ERR Line
ERR Cmd.
Action
Communication is executed normally.
The receive data is sent continuously with a short interval.
Let the baud rate (communication speed) be equivalent between the GOT and counterpart equipment.
The communication frames of GOT and PLC are inconsistent.
Confirm the communication settings of GOT and PLC, such as data length, stop bit and baud rate.
The parity check conditions of GOT and PLC are inconsistent.
Let the parity check condition (odd or even) of GOT and PLC be consistent.
The sum data is inconsistent. Or the contents of the receive data are not consistent with the send command from the GOT.
Let the communication settings and contents of data be consistent between the GOT and counterpart equipment.
(If NAK is received while the GOT is connected to the micro computer board, a text error occurs.)
Though receiving is started, receive data is not sent.
Check the wiring between the GOT and its communication target.
(When the GOT is connected to the micro computer board, confirm the terminator, CR, wiring, etc.)
The control line is not operating correctly. Confirm the wiring of the control line.
A command contained in the receive data is not consistent with the send command from the GOT.
9
10
11
12
13
14
15
16
11.3 Communication Monitor
11.3.3 Screen display content
11 - 17
11.4 Keyword
11.4.1 Keyword functions
The operation related to a keyword of the FX series PLC can be performed.
Regist
Delete
Clear
Protect
Function Contents
Keyword is registered.
Registered keyword is deleted.
Keyword protection is cancelled.
A keyword with cancelled protection is reactivated for protection.
How to use the keyword function
To use a keyword, the standard monitor OS[01.10.**] or later and the communication driver MELSEC-FX[01.06.**] or later must be installed on the GOT.
For the details of OS installation, refer to the following images.
11.4.2 Keyword display operation
Main Menu
Touch [Comm. Setting].
Touch .
GT1020
Touch [keyword].
GT104 , GT105
11 - 18
11.4 Keyword
11.4.1 Keyword functions
11.4.3 Regist
Keyword is registered.
Touch
9
1
Touch
"
Regist
"
to display the selection screen for the registration.
For the FX series PLC, which is not compatible with Customer Keyword, the keyword entry screen of ) is displayed.
Start the operation from ).
For the Customer Keyword compatible models, refer to the manual of the PLC to be used.
10
11
2
Select [Keyword] or [Keyword + Custom].
To register only Keyword and 2nd keyword, touch [Keyword].
To register Customer Keyword, touch
[Keyword + Custom].
12
3
Touch the display part of the keyword to be registered.
13
Touch
Touch
Touch
4
The keyboard for entering a keyword is displayed. Enter a keyword and touch the
ENT
key.
For the keyword, 8 digits from 0 to 9 or A to
F must be set.
14
5
After completing the keyword entry, touch
Next
.
When [Keyword + Custom] is selected on the selection screen for the registration, the
Customer Keyword entry screen is displayed.
Enter it in the same way as for Keyword and 2nd keyword.
15
16
11.4 Keyword
11.4.3 Regist
11 - 19
11 - 20
11.4 Keyword
11.4.3 Regist
Touch
Touch
Touch
6
Set Registration conclition.
Touch Registration conclition to change the setting contents.
All Protect Write Protect R/W Protect
7
After setting Registration conclition, touch the [Execute] key.
The registration of the keyword is completed.
8
After the completion of the keyword registration, touch
OK
9
(1) Selection availability of Registration conclition
The following table lists the PLCs that can select Registration conclition.
Target PLC
Settings
When keyword and 2nd keyword are registered
When only keyword is registered
FX PLC compatible with 2nd keyword
*1
FX PLC not compatible with
2nd keyword
*1
Registration options can be selected.
-
Registration options
*2
cannot be selected.
*1: Refer to the manual for the PLC in use for the models that are compatible with the 2nd keyword.
*2: Registration options
Options can be selected among "Read/Write Protect", "Write Protect", or "All online operation protection".
For access restrictions of each setting, refer to the manual of the PLC to be used.
(2) Selection of keyword protection level
For the devices which can perform the online operation of FX PLC, 3 levels of protection can be set.
When the monitoring or setting change by online devices is needed, set the keyword taking the following into consideration.
(a) When only keyword is registered
Protection level is selected by the head character of keyword.
All Protect: Set the keyword starting with one of A, D to F, or 0 to 9.
Read/incorrect write protection: Set the keyword starting with B.
Erroneous write prohibition: Set the keyword starting with C.
(b) When keyword and 2nd keyword are registered
Protection level is selected by "Registration options".
(3) Applicability of monitoring for each keyword protection level
The applicability of monitoring for each protection level is as follows.
10
11
12
13
Setting items
When only keyword is registered
All Protect
Read/ incorrect write protection
Erroneous write prohibition
When keyword and 2nd keyword are registered
All online operation protection
Read/
Write prohibition
Write
Protect
Keyword unregistered/ protection cancelled
Device monitoring
Device change
T, C setting values and file register
(from D1000)
Other than the above
*1 *1 *1
*1: When the T, C set values are specified indirectly, changing devices is available.
14
15
(4) Difference between "All online operation protection" and "All Protect"
When "All online operation protection" is selected, both device display and input by the programming tool or GOT are prohibited.
When "All Protect" is selected, device display and input are possible although operations by the programming tool are all prohibited.
16
11.4 Keyword
11.4.3 Regist
11 - 21
11.4.4 Delete
Registered keyword is deleted.
1
Touch [Delete] to display the keyword entry screen.
Touch
Touch
Touch
2
Touch the display part of the registered keyword.
Target PLC
FX PLC compatible with
2nd keyword
Settings
Input a keyword to be deleted.
FX PLC not compatible with 2nd keyword
Input a keyword to be deleted only into
"keyword".
"2nd keyword" is ignored.
3
The keyboard for entering a keyword is displayed. Enter a keyword and touch the
ENT
key.
4
After completing the keyword entry, touch
Next
.
Touch
5
Touch the [Execute] key.
Touch
6
The keyword is deleted.
7
Touch .
Touch
11 - 22
11.4 Keyword
11.4.4 Delete
11.4.5 Clear
To access an FX PLC where a keyword has been registered, keyword protection is cancelled.
1
Touch [Clear] to display the keyword entry screen.
Touch
9
10
Touch
2
Touch the display part of the registered keyword.
Target PLC
FX PLC compatible with customer keyword
FX PLC compatible with
2nd keyword
Settings
Input a keyword or cutomer keyword to cancel the protection.
Input a keyword to cancel the protection.
FX PLC not compatible with 2nd keyword
Input a keyword into "keyword" to cancel the protection.
"2nd keyword" is ignored.
11
12
3
The keyboard for entering a keyword is displayed. Enter a keyword and touch the
ENT
key.
13
Touch
4
After completing the keyword entry, touch
Next
.
14
Touch
5
Touch the [Execute] key.
15
Touch
6
The protection is cancelled.
16
Touch
11.4 Keyword
11.4.5 Clear
11 - 23
11.4.6 Protect
A keyword with cancelled protection is reactivated for protection.
Keyword protection function is valid when the 2nd keyword is registered.
1
Touch [Protect] to switch to the keyword protection status.
Touch
11 - 24
11.4 Keyword
11.4.6 Protect
12. DISPLAY AND OPERATION
SETTINGS (GOT SET UP)
Setting screen for display and setting screen for operation can be displayed from GOT setup.
In the setting screen for display and the setting screen for operation, the following settings can be set.
Description
Screen
Setting screen for display
Setting screen for operation
GT1020 GT1030
Screen save time
Screen save backlight
Contrast
Opening time
Bright/Contrast
Buzzer volume, Window move buzzer
Calibration
Key reaction
Clock setting
Security
Utility call
Contrast
GT104
-
GT105
10
11
12
Backlight color change and backlight blink settings
The backlight color change and backlight blink settings of GT1020 and GT1030 are executed on the drawing software.
Right-click the screen to change the backlight settings on the drawing software, and select [Screen Property].
On GT Designer2, the [Auxiliary] tab is displayed. On GT Designer3, the [Basic] tab is displayed.
Select the backlight color and backlight blink and click the button.
For GT Designer3
13
14
9
15
Also, the backlight color can be changed from the system information.
For details of the system information, refer to the following manual.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual
12 - 1
16
12.1 Display Settings
12.1.1 Display setting functions
Setting regarding display is possible. The items which can be set are shown below.
Contents
Items
GT1020 GT1030
GT104 GT105
Screen save time
Screen save backlight
Brightness
The period from the user stops the touch panel operation till the screen save function starts can be set.
Whether turn ON or OFF the backlight simultaneously at the screen save function start can be specified.
-
The brightness can be adjusted.
-
Setting range
0 to 60 minutes
<At factory shipment: 0 minutes>
When set to 0, the function becomes invalid.
ON/OFF
<At factory shipment: OFF>
8-level adjustment (0 to 7)
Contrast
Opening time
Contrast can be adjusted.
The title display period at the main unit boot can be set.
16-level adjustment (0 to 15)
<At factory shipment: 10>
0 to 60 seconds
<At factory shipment: 5 seconds >
(1) Display setting by drawing software
Set title display period, opening time, screen save time and screen save backlight at [GOT set up] in [System Environment] of GT Designer2.
When using GT Designer3, execute the settings at [GOT Setup...] in [[GOT
Environmental Setting] of [Common].
When change a part of the setting after downloading the project data, change the setting by [Display] screen of the GOT.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
(2) Screen save and screen save backlight OFF function
When using the screen save and screen save back light OFF function, select valid/invalid by the system information reading device in [System Environment] of
GT Designer2.
When using GT Designer3, select valid/invalid by the reading device of [System
Information...] in [GOT Environmental Setting].
For system information details, refer the following.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
12 - 2
12.1 Display Settings
12.1.1 Display setting functions
12.1.2 Display operation of display setting
Main Menu
Display
Touch .
GOT setup
Touch [GOT setup].
Touch [Display].
9
10
11
12
13
14
15
16
12.1 Display Settings
12.1.2 Display operation of display setting
12 - 3
12.1.3 Display setting operations
1
Screen save time
Display
1
Touch [Screen Save] to bring up the screensaver setting window.
Touch [Screen save].
2
Touch [Time] to bring up the time setting window.
Touch [Time].
3
Touch the time that appears on the time setting window to bring up the ten-key pad.
Touch
Touch
4
Enter the time using the ten-key pad.
“0” to “9” : Use these keys to enter numerical values. Enter "0" to disable the screensaver function
“ESC” : Closes the ten-key window without saving any value entered
“AC” : Deletes the entire string of numerical characters that are being entered
“DEL” : Deletes a digit from a string of numerical characters that are being entered
“ENT” : Enters the value for the clock that has been entered and closes the ten-key pad window
“+ /
−”
: Switches between positive and negative values (Only positive values are valid for the clock setting.)
“ . ” : Invalid key (not used)
5
When all the settings have been made, touch the
ESC
button to close the setting window.
12 - 4
12.1 Display Settings
12.1.3 Display setting operations
2
Screen save backlight
Display
OFF
Touch [Screen save].
Touch [Backlight].
ON
9
1
Touch [Screen Save] to bring up the screensaver setting window.
10
2
Touch [Backlight] to bring up the backlight setting window.
11
3
Touch the
OFF the backlight.
/
ON
button to turn off/turn on
•
•
OFF
button: Screen save, Transferring...,
Backlight, Unlit
ON
button: Screen save, Transferring...,
Backlight, Lit
12
13
Touch
4
After changing the settings, touch the
ESC button to save the changes and close the setting window.
14
15
16
12.1 Display Settings
12.1.3 Display setting operations
12 - 5
3
Contrast
Display
1
Touch [Contrast] to bring up the setting window.
Touch [Contrast].
2
Touch the [
−] and [+] buttons to adjust the contrast of the screen.
Adjust contrast with the [
−] and [+] buttons.
Touch
3
After changing the settings, touch the
ESC button to save the changes and close the setting window.
4
Brightness
<For GT1030>
Display
1
Touch [Bright/Contrast] to bring up the setting window.
Touch [Bright / Contrast].
2
Touch the [
−] and [+] buttons to adjust the brightness of the screen.
Adjust brightness with the [
−] and [+] buttons.
Touch
3
After changing the settings, touch the
ESC button to save the changes and close the setting window.
12 - 6
12.1 Display Settings
12.1.3 Display setting operations
5
Opening time
Display
Touch
Touch
Touch [Opening time].
Touch
9
1
Touch to bring up the [Opening time] setting window.
10
2
Touch [Opening time] to bring up the setting window.
11
3
Touching the set time (value) can change the setting.
12
4
After changing the settings, touch the
ESC button to save the changes and close the setting window.
13
14
15
16
12.1 Display Settings
12.1.3 Display setting operations
12 - 7
12.2 Operation Settings
12.2.1 Operation setting functions
Setting regarding GOT operation can be set.
The items which can be set are described below.
Function
GT1020
Contents
GT1030
GT104 GT105
Setting range
Buzzer volume Buzzer volume setting can be changed
Window move buzzer volume
Calibration
Key reaction
Whether turn ON/OFF buzzer when move window can be selected
Touch panel sensitivity can be adjusted using this function
−
The sensitivity of touch panel when GOT screen is touched can be set
OFF/SHORT/LONG
<At factory shipment: SHORT>
ON/OFF
<At factory shipment: ON>
−
<At factory shipment: already adjusted>
±0 to +120 *1
For GT1020 : None, Adjust
Clock setting
Security
Utility call
Set the method to adjust the time between the GOT clock data and clock data of the connected controller.
Security level screen can be displayed
Utility call key setting screen can be displayed
For GT1030, GT104 , GT105 :
None, Adjust, Broadcast, Both
<At factory shipment: Adjust>
−
−
*1 The more the value set for [Key reaction] is high, the more the key reaction speed slows.
"Key reaction" [ms] Standard(±0) +10 +20 +40 +80 +120
For example, when the GOT recognizes touching the GOT screen once as touching the screen twice, set a higher value for [Key reaction].
Operation settings by drawing software
Set buzzer volume and window move buzzer volume by [GOT setup] in [System
Environment] of GT Designer2.
When using GT Designer3, execute the settings at [GOT Setup...] of [GOT
Environmental Setting].
When change a part of the setting, change the setting by the GOT display setting after downloading the project data.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
12 - 8
12.2 Operation Settings
12.2.1 Operation setting functions
12.2.2 Display operation of operation setting
Main Menu
Operation*
Touch .
GOT setup
Touch [GOT setup].
*: GT1030, GT104 , GT105 does not have [Calibration] function.
Touch [Operation].
9
10
11
12
13
14
15
16
12.2 Operation Settings
12.2.2 Display operation of operation setting
12 - 9
12.2.3 Setting operation of operation
1
Buzzer volume
Operation
1
Touch [Buzzer setting] to bring up the buzzer volume setting window.
Touch [Buzzer setting].
2
Touch [Buzzer volume] to bring up the setting window.
Touch [Buzzer volume].
3
Touch a setting item to change the setting.
(Buzzer volume:
SHORT LONG OFF
)
Touch
Touch
4
After changing the settings, touch the
ESC button to save the changes and close the setting window.
12 - 10
12.2 Operation Settings
12.2.3 Setting operation of operation
2
Window move buzzer
Operation
Touch [Buzzer setting].
Touch [Window move].
Touch
Touch
9
1
Touch [Buzzer setting] to bring up the buzzer volume setting window.
10
2
Touch [Window move] to bring up the setting window.
11
3
Touch a setting item to change the setting.
(Window move buzzer:
ON OFF
)
12
4
After changing the settings, touch the
ESC button to save the changes and close the setting window.
13
14
15
16
12.2 Operation Settings
12.2.3 Setting operation of operation
12 - 11
3
Calibration
<For GT1020>
Operation
Touch
Touch [Calibration].
1
Touch [Calibration] to bring up the setting screen.
2
Touch the "+" symbol at the top left corner.
3
Touch the "+" symbol at the bottom left corner.
Touch
Touch
4
Touch the "+" symbol at the top right corner.
5
Touch the "+" symbol at the bottom right corner.
Touch
6
5
completes the calibration process, and the
[Operation] window will reappear.
12 - 12
12.2 Operation Settings
12.2.3 Setting operation of operation
4
Key reaction
Operation
Touch panel calibration error
If touch panel calibration results in inoperability of the panel, the following message will appear.
9
10
YES
button: Returns to the touch panel calibration screen.
NO
button: Aborts calibration without saving any changes to the touch panel setting.
11
1
Touch to bring up the [Key reaction] setting window.
12
Touch
2
Touch [Key reaction] to bring up the setting window.
13
Touch [Key reaction].
3
Touch a setting item to change the setting.
14
Touch
Touch
4
After changing the settings, touch the
ESC button to save the changes and close the setting window.
15
16
12.2 Operation Settings
12.2.3 Setting operation of operation
12 - 13
5
Clock setting
Setup the method to adjust the time between GOT data and the clock data of PLC CPU connected with
GOT.
Setting Contents
Adjust the time of GOT clock data to the clock data of PLC CPU.
Adjust
Same as setting in [GOT setup] in [System Environment] of GT Designer2.
Same as setting in [GOT Setup...] in [GOT Environmental Setting] of GT Designer3.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
Adjust the time of PLC CPU clock data to the clock data of GOT.
Broadcast
Same as setting in [GOT setup] in [System Environment] of GT Designer2.
Same as setting in [GOT Setup...] in [GOT Environmental Setting] of GT Designer3.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
Adjust and Broadcast can be used appropriately.
Both
None
Same as setting in [GOT setup] in [System Environment] of GT Designer2.
Same as setting in [GOT Setup...] in [GOT Environmental Setting] of GT Designer3.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
No adjustment of clock data.
Operation
1
Touch [Clock setting] to bring up the setting window.
Touch [Clock setting].
Touch
2
Touch a setting item to change the setting.
GT1020 : None Adjust
GT1030
GT104
GT105
: None Adjust Broadcast Both
3
After changing the settings, touch the
ESC button to save the changes and close the setting window.
Touch
12 - 14
12.2 Operation Settings
12.2.3 Setting operation of operation
6
Security
Operation
Touch [Security].
Touch
Touch
9
1
Touch [Security] to bring up the setting window.
10
2
Touching [Security level] displays the password input window.
Inputting the password set in the password input window can change the security level.
3
After changing the settings, touch the
ESC button to save the changes and close the setting window.
11
12
13
14
15
16
12.2 Operation Settings
12.2.3 Setting operation of operation
12 - 15
7
Utility call
Operation
1
Touch [Utility call] to bring up the setting window.
Touch [Utility call].
Touch bottoms to set for the Utility call key.
Touch
2
Touch or displayed on the four corners of the setting screen.
The button repeats pressed.
every time it is
Change the part to be set as a key position to
.
3
When the key position is specified by one point, the time to switch to the utility when the key position is kept pressing can be set.
Touch the time area.
4
After changing the settings, touch the
ESC button to save the changes and close the setting window.
When using GT1020
For the key position, 1 point only can be set.
8
12 - 16
12.2 Operation Settings
12.2.3 Setting operation of operation
13. CLOCK SETTINGS AND BATTERY
STATUS DISPLAY
(TIME SETTING AND DISPLAY)
10
The clock data (date and time) are displayed and set in the clock setting menu.
The voltage status of the built-in battery is also displayed.
13.1 Time Setting and Display
13.1.1 Time setting and display functions
Time settings and displaying of the status of GOT built-in battery are possible.
Contents
Function
Clock display
GT1020
Carry out the display and setup of PLC CPU clock data.
GT1030 GT104 GT105
Carry out the display and setup of PLC CPU or GOT's clock data.
GOT internal battery voltage status
− Displays GOT internal battery voltage status.
13.1.2 Clock display and setting operation
11
12
13
9
Main Menu(For GT1030)
14
Touch [Time setting].
Touch .
15
Time setting*
*: GT1020 does not have [Battery voltage].
16
13.1 Time Setting and Display
13.1.1 Time setting and display functions
13 - 1
13.1.3 Clock setting operations
1
Clock display
Displays and sets up the clock data on the GOT.
When setting the clock data, change the clock data on the GOT and controller regardless of clock setting.
The setup methods of clock data are shown below.
1
Touch either the date or time to be changed.
Touch the item to be changed.
Touch
2
Enter date or time on the ten-key pad.
The day of the week is displayed automatically according to the input date.
“0” to “9” : Use these keys to enter numerical values
“ESC” : Closes the ten-key window without saving any value entered for the date or time
“AC” : Deletes the entire string of numerical characters that are being entered
“DEL” : Deletes a digit from a string of numerical characters that are being entered
“ENT” : Enters the value for the date or clock that has been entered and closes the ten-key pad window
“+ /
−”
: Switches between positive and negative values (Only positive values are valid for the date or clock setting.)
“ . ” : Invalid key (not used)
3
After changing the settings, touch the
ESC button to save the changes and close the setting window.
13 - 2
2
GOT internal battery voltage status
Displays battery voltage status. <For GT1030, GT104 , GT105 >
Display Status
Normal
Low/None
Normal
Low voltage
When the battery voltage is low, replace the battery immediately.
Refer to the following for battery replacement procedure.
13.1 Time Setting and Display
13.1.3 Clock setting operations
14. FILE DISPLAY (DATA)
This function displays the version of the OS (Standard monitor OS, BootOS) and communication driver that are written to the GOT. Project data and resource data can be deleted with this function.
10
14.1 Data Storage Location
The following drive name (C or D drive) is assigned to the built-in Flash Memory or SRAM on the GOT.
Allocation GOT
GT1020
GT1030
GT104
GT105
Drive name
C drive
C drive
D drive
C drive
D drive
C drive
D drive
Flash Memory (Internal)
Flash Memory (Internal)
Internal SRAM
Flash Memory (Internal)
Internal SRAM
Flash Memory (Internal)
Internal SRAM
11
12
9
13
14
15
16
14.1 Data Storage Location
14 - 1
14.2 OS Information
14.2.1 Function of OS information
This function displays the version of the OS (Standard monitor OS, BootOS) and communication driver on the built-in flash memory (C drive).
14.2.2 Display operation of OS information screen
Main Menu
OS information
<For GT1020>
Touch .
Data
Touch [Data].
Touch [OS information].
<For GT1030>
<For GT104 , GT105 >
14 - 2
14.2 OS Information
14.2.1 Function of OS information
14.2.3 OS information operation
1
OS information display (For GT1020)
9
1
Touch the and buttons to toggle through the version of the [Standard monitor OS],
[Communication driver], and [BootOS].
2
Touch the
ESC
button to close the screen.
10
11
12
13
14
15
16
14.2 OS Information
14.2.3 OS information operation
14 - 3
14.3 Font Data
14.3.1 Function of font data
The types of fonts that are stored in the C: Built-in flash memory.
14.3.2 Display operation of font data screen
Main Menu
Font data
<For GT1020>
Touch .
Data
Touch [Data].
Touch [Font data].
<For GT1030>
<For GT104 , GT105 >
14 - 4
14.3 Font Data
14.3.1 Function of font data
14.3.3 Font data operation
1
Font data display (For GT1020)
9
1
Touch and button to switch the display of fonts that are stored in the C: Built-in flash memory.
2
Touch the
ESC
button to close the screen.
10
11
12
13
14
15
16
14.3 Font Data
14.3.3 Font data operation
14 - 5
14.4 Clear data
14.4.1 Clear data functions
This function deletes the project data and resource data that are written to the GOT.
14.4.2 Clear data display
Main Menu
Clear data
Touch .
Data
Touch [Data].
Touch [Clear data].
14.4.3 Clear data operation
1
Touch the type of data on the screen to be deleted.
Touch [Project data] or [Resource data].
2
The dialog mentioned left is displayed for confirmation.
Touch the
YES
button to delete the data, or the
NO
button to cancel.
Touch
Remark
Canceling deletion
Data deletion cannot be cancelled once the
YES
button is pressed at the confirm deletion prompt. Double check before touching the
YES
button.
14 - 6
14.4 Clear data
14.4.1 Clear data functions
14.5 GT10-50FMB
9
14.5.1 GT10-50FMB functions (For GT104
[ ]
, GT105
[ ]
only)
Use the GT10-50FMB type memory board to transfer the project data or OS.
10
Copy from the memory board to the GOT
Copying from the memory board to the GOT when turning on the power to the GOT.
Refer to the following.
Section 17.3 Standard Monitor OS/Communication Driver Installation
14.5.2 GT10-50FMB display operation
11
Main menu
12
GT10-50FMB Data
Touch [Data].
Touch [GT10-50FMB].
15
16
13
14
14.5 GT10-50FMB
14.5.1 GT10-50FMB functions (For GT104[ ], GT105[ ] only)
14 - 7
14.5.3 GT10-50FMB operation
Touch
1
Select the copy direction.
The selection mark is displayed on the side of the selected key.
- GOT FMB:Copy from the GOT to the memory board
- FMB GOT: Copy from the memory board to the GOT
2
After selecting the direction, touch the
[OK] button.
To abort copy touch the [ABORT] button.
Touch
Touch
3
Select the copy target.
The selection mark is displayed on the side of the selected key.
- OS+Projectdata: Copies the standard OS, communication driver and projectdata
- Projectdata : Copies the projectdata
4
After selecting the copy target, touch the
[OK] button.
To return to the copy direction setting screen, touch the [CANCEL] button.
Touch
14 - 8
14.5 GT10-50FMB
14.5.3 GT10-50FMB operation
Touch
Touch
5
When the transfer direction is set to
"GOT FMB" and the copy target is set to "OS+Projectdata" with the ver01.11.** or later of the standard monitor OS of the
GOT, a window confirming the copy of the font data is displayed.
Select YES/NO to decide whether to copy the font data or not.
The selection mark is displayed on the side of the selected key.
Touch the [OK] button when the setting is correct, and touch the [CANCEL] button to return to the copy direction selection.
6
Confirm the copy direction and copy target.
When they are set correctly, touch the
[OK] button.
To change the setting, touch the
[CANCEL] button.
9
10
11
12
7
The dialog box on the left is displayed for confirmation.
Touch the [YES] button to start copying and [NO] button to abord.
13
14
8
While the copy is executed, the dialog box on the left is displayed.
15
16
14.5 GT10-50FMB
14.5.3 GT10-50FMB operation
14 - 9
Touch
9
Copy is completed.
Touch the ESC button to close the screen. If an error occurs during copy, an error message appears.
For details of error messages, refer to the following.
When only the project data was copied to the GOT, touch the ESC button to restart the GOT and display the usercreated screen.
When the standard OS was copied, the
GOT will automatically start up and display the user-created screen.
(If the project data does not exist, a message appears to notify that the project data does not exist.)
Precautions for installing/removing the memory board
When installing or removing the memory board, be sure to power off the GOT main unit.
14.5.4 Error display
When copying is not available between the GOT and the memory board, check the following contents according to the GOT error display.
Error message
The version of the standard monitor OS of the GOT main unit does not match with that of the project data in GOT10-50FMB.
Remedy
The major version of the standard monitor OS of the GOT main unit does not match with that of the project data in GOT10-50FMB.
Match the version of the standard monitor OS of the GOT main unit to the major version of the project data in GOT10-50FMB.
The model information does not match.
The write protection switch of GT10-50FMB is ON.
There is no valid copy target data in the copy source.
The data selected as a copy target is not stored in GT10-50FMB.
Select the copy target correctly and copy it again.
The model set for the data in GOT10-50FMB does not match with that of the copy target GOT.
Use the same model data as that of the copy target GOT.
The write protection switch of GT10-50FMB is ON.
Turn off the write protection switch.
There is no data to be a copy target in the copy source.
Store the data to be copied in the copy source and copy it again.
14 - 10
14.5 GT10-50FMB
14.5.4 Error display
15. GOT DEBUG
15.1 Debug
The debug includes functions to check the PLC system status and to improve troubleshooting efficiency.
The following is available as the debug.
Contents
Items
GT1020 GT1030 GT104 GT105
Device monitor
FX list editor
For a controller connected to the GOT, forcibly turning on or off devices of the controller and changing the set value or present value are available.
-
Sequence program and parameter change of FX
PLC.
15.2 Device Monitor
For a controller connected to the GT10 , forcibly turning on or off devices of the controller and changing the set value or present value are available.
15.2.1 System cofiguration
This section describes the controller names and connection types between the GOT and a controller that are applicable to the device monitor function.
For details of communication units and cables for each connection type, refer to the following manual.
GOT1000 Series Connection Manual
10
12
9
11
1
Target controller
Controller
*1
QCPU (Q mode)
QnACPU
Connection type
Direct CPU connection, Computer link connection, CC-Link(G4) connection
Direct CPU connection, Computer link connection
ACPU, QCPU (A mode) Direct CPU connection, Computer link connection
FXCPU Direct CPU connection
*1 : For details of controllers that can be monitored, refer to the following manual.
GT Designer2 Version Screen Design Manual
GOT1000 Series Connection Manual (Mitsubishi Products)
13
14
2
Required OS
The OS shown in the table below is required.
OS
Standard monitor OS
Communication driver
MELSEC-FX
QnA/Q
MELSEC-A
AJ71C24/UC24
CC-Link(G4)
01.09.** or later
01.04.** or later
Version
15
Checking method of OS, Communication driver version
Check the version of OS or communication driver installed in GOT at [OS information] of the utility.
Refer to the following for details.
15.1 Debug
15.2.1 System cofiguration
15 - 1
16
15.2.2 Devices that can be monitored
For further information about the monitor device names that can be monitored and the scope, see the following:
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
15.2.3 Precautions
(1) Monitoring and testing real number data
Real number data cannot be monitored and tested.
All word devices containing real number data are monitored in integer data (binary data).
(2) Monitoring devices in 32-bit (two-word) module
When monitoring word devices (T, C, D, W, etc.) in 32-bit (two-word) module, those with 32 bits of data remaining are monitored.
Devices with 16 bits (one-word) of data remaining are not monitored.
If an odd number is specified for the first monitor device number, the last device number of the specified controller will not be displayed.
(Example) When the data entry of the A2NCPU is monitored in units of 32 bits from odd numbers
(D1, D3 ...)
D1017 D1018 D1019 D1020 D1021 D1022 D1023
(Device name)
Unit of monitor display
Nothing displayed
(3) Changing the timer/counter set values of QnACPU
The timer/counter set values of QnACPUs whose date on the CPU rating plate is after [9707B] can be changed.
<Information on the rating plate>
PROGRAMMBLE CONTROLLER
DATE 9707 B
Date of manufacture Function version
(4) Programs capable of changing timer/counter set values
Only the main program can change the timer/counter set values of AnNCPUs, AnACPUs, and
AnUCPUS.
15 - 2
15.2 Device Monitor
15.2.2 Devices that can be monitored
15.2.4 Display operation of device monitor
Main Menu
Device monitor
<For GT1020>
Touch .
Debug
Touch [Debug].
Touch [Device monitor].
<For GT1030>
9
10
11
12
13
<For GT104 , GT105 >
14
15
16
15.2 Device Monitor
15.2.4 Display operation of device monitor
15 - 3
15.2.5 Information displayed on the device monitor screen and key functions
1
Device monitor screen
The information displayed on the device monitor screen is described below.
For GT1030
1) 2) 3)
5)
For GT104 , GT105
6) 8)
4)
7)
For GT1020
No.
1)
2)
3)
4)
5)
Device name
Device No.
Bit device ON/OFF
Timer/Counter contact ON/OFF
Data type
Item
Present value of word device
Present value and set value of timer/ counter
*1
Description of setting
Displays the device name.
Displays the device number.
Displays ON/OFF information of bit devices and timer/counter contacts
: ON : OFF
DW : FIndicates that the device value is a 32-bit (two-word) module.
Nothing displayed: Indicates that the device value is a 16-bit (oneword) module.
[Decimal number]
16-bit (one-word) module: Six digits (including a digit for a sign) are displayed. (Display example: -12345)
32-bit (two-word) module: Ten digits (including a digit for a sign) are displayed. (Display example: -123456789)
[Hexadecimal number]
16-bit (one-word) module: Four digits are displayed. (Display example: H AB12)
32-bit (two-word) module: Eight digits are displayed. (Display example: H ABCDE123)
15 - 4
15.2 Device Monitor
15.2.5 Information displayed on the device monitor screen and key functions
No.
6)
7)
8)
Counting method
Item Description of setting
Displays the counting method when registering the counters from
C200 to C255.
UP: Up count mode DOWN: Down count mode
Displays the reset coil state when registering the timer/counter for the
FXCPU.
Reset coil ON/OFF
CPU No. specification
: ON : OFF
0 to 4: This item must be set only when the GOT is connected to the
Q series CPU in the multiple CPU system or QnUCPU.
Changing the CPU No. cancels the registration for all the devices.
Section 15.2.7 Device registration
*1 : Displays the values set for the timer/counter when registering the timer/counter for the ACPU, QnACPU, or
FXCPU.
9
10
11
2
Key functions
The following table describes the key functions displayed on the device monitor screen.
Key switch
DEV
Function
Switches the screen to the device registration key window for registering devices to be monitored.
Section 15.2.7 Device registration
TEST
DEC/HEX
ESC
Switches the quick test mode between enabled and disabled states.
Switches the numerical notation of word device values between decimal and hexadecimal numbers. (GT1030 only)
: Scrolls the list up by one line to display the device number right before the device number displayed in the top line.
: Scrolls the list down by one line to display the device number right after the device number displayed in the bottom line.
Exits the device monitor, and then the screen returns to the debug screen.
12
13
14
15
16
15.2 Device Monitor
15.2.5 Information displayed on the device monitor screen and key functions
15 - 5
15.2.6 Basic operation of device monitor
The following explains basic operations of the device monitor.
Debug
With no registered device
Touch [Device monitor].
With registered devices
DEV
Touch
Register devices if necessary.
Section 15.2.7 Device registration
TEST
Touch
Execute the quick test if necessary.
DEC/HEX
Touch
Switch the numerical notation of word device values between decimal and hexadecimal numbers if necessary.
15 - 6
15.2 Device Monitor
15.2.6 Basic operation of device monitor
15.2.7 Device registration
The following explains the procedures for device registration.
Device monitor
9
10
Connecting to a Q series CPU in the multiple CPU system or QnUCPU
Specify a CPU No. for the devices to be registered.
Touch
11
Connecting to a CPU other than the Q series
CPU in the multiple CPU system and QnUCPU
12
Input the CPU No. with the ten-key, and then touch the
ENT key.
13
Touch the DEV key.
Touch
1) 2) 3)
When registering multiple devices, repeat the procedures.
Set 1) to 3) by using the keyboard, and then touch the ENT key.
The device registration is completed.
Keyboard
For the keyboard operations, refer to the next page.
No.
1)
Item
Data type
Description of setting
32 : FIndicates that the device value is a 32-bit (two-word) module.
Nothing displayed: Indicates that the device value is a 16-bit (one-word) module.
2)
3)
Device name
Device No.
Set the device name and device number to be monitored.
15.2 Device Monitor
15.2.7 Device registration
15 - 7
14
15
16
Keyboard operations
(1) Keyboard functions
Device name keyboard
Device number keyboard
Ends the device registration.
Select a data type.
[32]: Sets to the two-word.
[16]: Sets to the one-word.
Switches device names on the keyboard.
Deletes all input numbers.
Ends the device registration.
Registers the input device.
(The device registration is completed.)
(2) Input procedures
Select a data type. (ex:16 bit)
Touch [16] key.
Touch [32] key.
Input a device number. (ex:12) Input a device name. (ex:D)
The device registration is completed by touching the ENT key.
15 - 8
15.2 Device Monitor
15.2.7 Device registration
9
Precautions for device registration
(1) Data type
Device monitor screens display the data type as shown below.
• DW : 32-bit (two-word) module
• Nothing displayed : 16-bit (one-word) module
(2) CPU No. specification
Changing the CPU No. after registering devices cancels the registration for all the devices.
Check the CPU No. before registering the devices.
(3) Holding registered devices
The registration for the devices is not canceled after exiting the device monitor.
Restarting the GOT cancels the registration for all the devices.
(4) The number of registered devices
The number of registered devices must be within the maximum number of devices that can be displayed on the GOT.
For registering an additional device, the registration for the device in the top line is canceled and the additional device is displayed in the bottom.
10
11
12
13
14
15
16
15.2 Device Monitor
15.2.7 Device registration
15 - 9
15.2.8 Quick test
DANGER
Before performing the quick test operations of device monitor (such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter), read through the manual carefully and make yourself familiar with the operation method.
During quick test operation, never change the data of the devices which are used to perform significant operation for the system.
False output or malfunction can cause an accident.
The quick test operation procedure for monitor devices is described below.
Device monitor
Enable the quick test mode.
(1) Quick test of bit devices
Touch
Check that the quick test operation is enabled.
(2) Quick test of word devices
15 - 10
15.2 Device Monitor
15.2.8 Quick test
(1) Quick test of bit devices
(Operation example)
Change the status of bit device M12 from OFF to ON
The device name and device number of the selected bit device are highlighted.
Touch the bit device to be switched between
ON and OFF states.
Touch
The selected bit device is switched from
(OFF) to (ON).
15
16
13
14
11
12
9
10
15.2 Device Monitor
15.2.8 Quick test
15 - 11
(2) Quick test of word devices
(Operation example)
Change the device value of word device D200 from 43 to 100.
Conditions: Data range: 16 bits, device value display format: decimal number
Touch the device value to be changed.
Input a device value by using the keyboard.
Input "100" for the operation example.
Touch ENT key.
The device value of D200 is changed from 43 to 100.
15 - 12
15.2 Device Monitor
15.2.8 Quick test
15.3 FX List Editor
(For GT104
[ ]
, GT105
[ ]
only)
GT104 , GT105 can edit the sequence programs of the connected FXCPU using the list editor.
15.3.1 Display operation of FX list editor
Main menu
9
10
11
FX list editor
Debug
Touch [Debug].
12
13
Touch [FX list editor].
14
15
16
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.1 Display operation of FX list editor
15 - 13
1
Parameters and sequence programs are easy to maintain.
You can check or partly correct, change or add FX PLC CPU parameters and sequence programs simply by operating keys.
You can easily edit sequence programs without preparing any peripheral unit other than the GOT.
(Example of changing sequence program commands)
Changed
LD X000
OUT Y020
LD X001
LD
OUT
LD
X000
Y030
X001
2
Errors that occur during list editing can be checked easily.
Error messages, error codes, and number of steps for errors that occur in the FX PLC can be checked.
Details can be checked immediately even for errors that occur during list editing.
3
Commands and devices can be searched and displayed.
Commands and devices used in sequence programs can be searched.
The correction position can be searched for cases such as when you want to correct a specific device.
Searched device
M800
Displays the searched device.
LD
OUT
LD
M 800
T 10
K 100
X 002
15 - 14
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.1 Display operation of FX list editor
15.3.2 Specifications
9
1
System configuration
This section describes the system configuration of the MELSEC-FX list editor.
For further information about communication units and cables for each connection form, see the following.
GOT1000 Series Connection Manual
10
2
Controllers that can be edited with the MELSEC-FX list editor
Target controller
FXCPU
3
Connection forms
Name
Function
Description
11
( : Available, : Unavailable)
Direct CPU connection
Connection form between GOT and PLC
Computer link connection
CC-Link connection
G4
*1
GOT multidrop connection
12
MELSEC-FX list editor
Sequence program writing, parameter setting, PLC diagnostics and keyword registration, etc.
*1 Indicates CC-Link connection (via G4).
13
14
15
16
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.2 Specifications
15 - 15
4
Functions list and monitor conditions
The following shows the memory that can be monitored by the MELSEC-FX list editor and the FX PLC status conditions.
Reading sequence programs
Writing sequence programs
Inserting commands
Deleting commands
Sequence program all clear
PLC diagnostics
Parameter setting
Keyword
Function
Displaying sequence programs
Searching commands/ devices
Writing commands
( : Can be monitored : Can be monitored under certain conditions : Cannot be monitored)
Built-in memory
Memory that can be monitored
*2
EEPROM
RAM memory cassette memory cassette, flash memory cassette
EPROM memory cassette
FX PLC status
Reference
Changing operands/set values
Display
Set
*1
*1
RUN/
STOP
For Stop only
RUN/
STOP
For Stop only
RUN/
STOP
*1 The operation is available only when the protect switch is OFF.
*2 The available memory differs depending on the FX PLC being used.
For further information, see the following manual.
The hardware manual of the FX PLC being used
15.3.3 Access range
The access range is the same as the access range when the GOT is connected to a controller.
Refer to the following manual for details of the access range.
GT Designer2 Version Screen Design Manual
GOT1000 Series Connection Manual (Mitsubishi Products)
15 - 16
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.3 Access range
15.3.4 Precautions
(1) Inapplicable GOT
The FX list editor function cannot be used with the GT1030 and GT1020.
(2) Using other peripheral equipment for sequence program/parameter change
When using the MELSEC-FX list editor, do not change programs or parameters in the PLC CPU from other peripheral equipment.
If you make a change, temporarily exit the MELSEC-FX list editor after the change is made, then start the MELSEC-FX list editor again.
If you carelessly change the program on one PLC from multiple units of peripheral equipment
(including GOT), the contents of the program in the PLC CPU and the peripheral equipment may not be the same, resulting in an unintended operation of the PLC CPU.
(3) Sequence program change
Stop the FX PLC before changing (writing, inserting, deleting) a sequence program or changing parameters.
Operation is not possible with the FX PLC running.
(4) If you press the
GO
key but the system does not proceed to the next operation (for example, a search)
Check the input contents (applied instruction number, device value, etc.).
(5) When using list monitor
Only devices to be used for basic instructions can be monitored.
The status of devices (word, bit) to be used for application instructions cannot be monitored.
9
10
11
12
13
14
15
16
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.4 Precautions
15 - 17
15.3.5 Display
1
Outline until the start
The following explains the outline until the operation screen of MELSEC-FX list editor is displayed.
Start
Turn on the power to the GOT.
Starting from the utility
Display the utility.
Starting from the special function switch (MELSEC-FX list editor) set in the project data
Touch the special function switch.
After the utility is displayed, touch
[Debug & self check] [Debug]
[MELSEC-FX List editor] from the main menu.
For how to display the utility, refer to the user's manual of the GOT to be used.
Refer to the following manual for how to set the special function switch.
GT Designer2 Version
Screen Design Manual
GT Designer3 Version
Screen Design Manua (Functions)
When no keyword is registered in the connected FX PLC
When a keyword is registered in the connected FX PLC
Enter the keyword.
Subsection 15.3.16 Keywords
The MELSEC-FX list editor is started.
End
(1) How to display the utility
For how to display the utility, refer to the following.
(2) If the project data has not been downloaded
The MELSEC-FX list editor can be started from the utility even if the project data has not been downloaded to the GOT.
15 - 18
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.5 Display
9
2
Change screens
This section describes how to change the screen.
Start
Utility Main Menu or user-created monitor screen
10
11
CLR OP
MORE
MORE
OP
CLR
[PLC diagnostics]
GO
[Parameter setting]
GO
12
13
[Keyword setup]
GO
14
*1
[List
Monitor]
GO
15
*1 With setting special function switches (FX list monitor), the list monitor can be started on the monitor screen.
When the list monitor is started on the monitor screen, the list editor cannot be used.
For how to set special function switches, refer to the following manual.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Functions)
16
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.5 Display
15 - 19
15.3.6 Operation Procedures
This section describes the contents of the MELSEC-FX list editor and the key functions displayed on the screen.
1
Key arrangement and a list of key functions
The arrangement and functions of the keys displayed on the MELSEC-FX List Editor window are described below.
2
Displayed contents
1)
2)
3) 4)
No.
1)
2)
3)
4)
Mode
Item
Error message
List display area
Key area
Description
Displays a mode for MELSEC-FX list editor. (
SubSection 15.3.7 Selection and operation of modes)
[Monitor] is displayed when the list monitor is executed.(
SubSection 15.3.17 List monitor)
Displays the contents of errors that occur with the MELSEC-FX list editor.
(
SubSection 15.3.19 Error Messages and Corrective Actions)
Displays the sequence program in list format (12 digits).
The position (line) that can be edited is displayed with a bar.
Displays the keys that can be used with the MELSEC-FX list editor.
15 - 20
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.6 Operation Procedures
9
3
Key functions
The table below shows the functions of the keys that are used for the operation on the MELSEC-FX list editor screen.
Key
Selects a mode for MELSEC-FX list editor. (
Function
SubSection 15.3.7 Selection and operation of
Displays the PLC diagnostics, parameter setting, and keyword selection menu.
Switches between command keyboard 1 and command keyboard 2.
(
"Keyboard switching" in this section)
When inputting commands :Cancels the key input when only part of the command has been input.
(
SubSection 15.3.18 Action for an incorrect key input)
When option menu is displayed: Closes the option menu.
Commands cannot be deleted with this key. (
SubSection 15.3.12 Deleting commands)
Space key.
This key is used when setting timers and counters, writing applied commands, etc.
10
11
12
Displays the list from a specified step No. when the step No. is input.
Moves the list display area bar up and down and switches the line being edited.
Determines the key operation.
13
to
to
,
, etc.
Inputs commands, device names, etc.
The key contents depend on the input contents.
The commands that can be used differ depending on the target FX PLC.
Refer to the manual for the FX PLC to be used.
Exits the MELSEC-FX list editor.
14
4
Keyboard switching
Touching the MORE button switches the command keyboard 1 and command keyboard 2.
When you touch the button for a keyboard function, the optimum keyboard for input for that function is displayed automatically.
Command keyboard 1
Command keyboard 2
15
Touch
16
Touch
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.6 Operation Procedures
15 - 21
15.3.7 Selection and operation of modes
The MELSEC-FX list editor has four modes: READ, WRITE, INSERT, and DELETE.
Select an appropriate mode for the intended operation.
For more information on the mode to select, refer to the function operations from subsection 15.3.8 onward.
1
How to change modes
Touch the MODE button.
Each time you touch this button, the mode changes.
Touch the button.
The current mode is displayed.
2
In the case the mode cannot be changed
In the following cases, only READ mode is allowed.
If you try to change to other than READ mode, an error message is displayed.
To change to other than READ mode, take the action below.
Error Message
PLC is running
Can not write.
Description
The FX PLC is in the RUN status.
The protect switch of the EEPROM memory cassette is on.
The EPROM memory cassette is enabled.
Corrective action
Stop the FX PLC.
Switch off the protect switch of the EEPROM memory cassette.
Set a memory other than EPROM as the memory to write to.
15 - 22
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.7 Selection and operation of modes
15.3.8 Sequence program display
Sequence programs are read from the FX PLC to the GOT and displayed.
There are two displaying methods: specifying the step number, and scrolling one screen at a time.
1
Display using cursor keys
(1) Operation
Scroll with or .
(2) Example
Scroll one line upward or downward.
128 MPP
129 DIV
D56
K200
23
Scrolling one line upward
128 MPP
129 DIV
D56
K200
23
Scrolling one line downward
128 MPP
129 DIV
D56
K200
23
2
Display specifying the step number
(1) Operation
STEP Input the step number.
GO
(2) Example
Displaying step number 123.
0 LD X
2 LDI M
3 MOV 12
STEP
Step number
3 MOV
GO
123 MOV
128 MPP
12 3
12
12
Input the step number
When the specified step number is the operand of an applied instruction
If the specified step number is a timer (T) or counter (C) set value or the operand of an applied instruction, that command section is displayed at the head.
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.8 Sequence program display
15 - 23
9
10
11
12
13
14
15
16
3
Display scrolling one screen at a time
(1) Operation
MODE
(Read mode)
GO
(2) Example
Displaying with scrolling one screen at a time.
< WRITE >
MODE
< READ > Set the READ mode.
GO
123 MOV
128 MPP
12
Displaying with scrolling one screen at a time.
15 - 24
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.8 Sequence program display
15.3.9 Searching commands and devices
Displays a command or device by searching it in sequence program from Step 0.
1
Command search
(1) Operation
MODE
(Read mode)
Select the command to search for.
*1
Input the device name and device number.
*2
GO GO
*3
*1 If the command you want to search for is not on the keyboard, touch the
MORE key to switch to the other keyboard.
When searching for an applied instruction, touch the
FNC
key and input the applied instruction number.
When searching for a label, touch
P
or
I
and input the pointer number.
(
*2 Input only when searching for commands requiring a device name and device number.
*3 After the search results are displayed, you can continue searching with the same conditions by touching the
GO
key.
Touching any key other than the GO key ends the search.
(2) Example
Searching for LD M8000.
MODE
LD
< WRITE >
< READ >
Set the
READ mode.
to search for.
Search command
LD
3 MOV 12
M 8 0 0 0 GO
8 LD
9 OUT
12 LD
M 8000
T 10
X 002
GO
(Continue to search with the
same conditions)
24 LD
25 OUT
28 OUT
M 8000
T 0
T 1
9
10
11
12
13
14
15
Pointer (P, I) searches
For pointer searches, only labels are searched.
Pointers specified as operands in applied instructions are not searched.
16
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.9 Searching commands and devices
15 - 25
2
Device search
(1) Operation
MODE
(Read mode)
SP
Input the device name and device number.
GO GO
* 1
*1 After the search results are displayed, you can continue searching with the same conditions by touching the
GO
key.
Touching any key other than the
GO
key ends the search.
(2) Example
Searching for LD M8000.
MODE
SP
< WRITE >
< READ >
Set the
READ mode.
M 8 0 0 0
Search device
3 MOV
M800 0
12
GO
8 LD
9 OUT
12 LD
T
X
10
002
GO
(Continue to search with the
same conditions)
24 LD
25 OUT T
M 8000
0
28 OUT T 1
Devices that cannot be searched
The following devices cannot be searched.
• Pointers, interrupt pointers
• Constant K, constant H, constant E
• Bit devices with specifying numbers only
• Special function unit/block buffer memory
• Devices specified with the operand of an applied instruction
(
Pointers and interrupt pointers can be searched for with command searches.
1
"Command search" in this section)
15 - 26
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.9 Searching commands and devices
15.3.10 Writing commands
Writes a sequence program to the FX PLC. (Overwrite/Insert)
1
Writing basic commands
(1) Operations
(a) Inputting command only (Ex.: ANB, ORB command etc.)
Stop the FX PLC
MODE
Input the command
For overwriting: (WRITE mode)
For insertion: (INSERT mode)
GO
(b) Inputting command and device (LD, AND commands etc.)
Stop the FX PLC MODE Input the command
For overwriting: (WRITE mode)
For insertion: (INSERT mode)
Input the device name and device number GO
(c) Inputting command, No. 1 device, No. 2 device (MC, OUT (T, C) commands, etc.)
Input the device name and device number
Stop the FX PLC MODE
Input the command
For overwriting: (WRITE mode)
For insertion: (INSERT mode)
SP
Input the device name and device number
GO
9
10
11
12
Moving the cursor to the position to write the command
When starting to write a command, place the cursor on the command line (the line on which the step number is displayed).
You cannot write a command with the cursor on an operand or set value line.
Command line (Place the cursor on this line.)
12
Operand, set value line (Cannot operate on this line.)
13
14
(2) Example
(a) Writing ORB command
Stop the FX PLC
15
< READ >
MODE
< WRITE >
Set the
WRITE or
INSERT mode
With or , move the cursor to the position to overwrite/insert the command.
ORB GO
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.10 Writing commands
15 - 27
16
(b) Inputting LD X000
Stop the FX PLC
< READ >
MODE
< WRITE >
Set the
WRITE or
INSERT mode.
With or , move the cursor to the position to overwrite/insert the command.
(c) Inputting OUT T100 K19
Stop the FX PLC
LD X 0 GO
< READ >
MODE
< WRITE >
Set the
WRITE or
INSERT mode.
With or , move the cursor to the position to overwrite/insert the command.
100 OUT
101 NOP
102 NOP
103 NOP
M 100
OUT T
M 100
T 100
100
SP K 19
M 100
T 100
K 19
GO
15 - 28
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.10 Writing commands
9
2
Writing applied instructions
(1) Operations
Stop the FX PLC
MODE FNC
For overwriting: (WRITE mode)
For insertion: (INSERT mode)
P
*1
SP
Input the device name and device number.
D
*1
Applied instruction number
GO
10
*2
*1
D
(double word command) and
P
(pulse execution format command) can also be input after the applied instruction number is input.
Inputting in the order P D is also possible.
*2 When a command specifies multiple devices for operations, input the
SP
key followed by the device name and device number.
11
(1) Moving the cursor to the position to write the command
When starting to write a command, place the cursor on the command line (the line on which the step number is displayed).
You cannot write a command with the cursor on any other line.
2 LDI
3 MOV
D
M 100
0
12
D 10
Command line (Place the cursor on this line.)
Operand, set value line (Cannot operate on this lin
12
(2) Commands using a text string constant for a command operand (such as ASC command)
With the MELSEC-FX list editor, text string constants cannot be written as operands. (such as ASC commands)
Use GX Developer for writing such commands.
(2) Example
Input "DMOVP D0 D2".
Stop the FX PLC
13
14
< READ >
MODE
< WRITE >
With or , move the cursor to the position to overwrite/insert the command.
Set the
WRITE or
INSERT mode.
D 1 2 P
SP
12
*1
D 0 SP
D 0
D 2
12
D 2
FNC
*1 The MOV command is FNC12.
GO
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.10 Writing commands
15 - 29
15
16
15.3.11 Changing operands, set values
Changes the operand section of an applied instruction and OUT (T, C) command set value.
1
Operation
Stop the FX PLC MODE
(Read mode)
SP
Input the device name and device number
GO
*1 For decimal numbers, input K, then the number.
For hexadecimal numbers, input H, then the number.
Moving the cursor to the line on which the operand or set value is to be changed
When starting to change an operand or a set value, place the cursor on the line of the operand or set value to be changed (the line on which the step number is not displayed).
If you place the cursor on the command line, the input operation is not possible.
D 0
D 10
12
Command line (Cannot operate on this line.)
Operand, set value line
(Place the cursor on this line.)
2
Example
Changing "MOV D0 D10" to "MOV D0 D123".
Stop the FX PLC
< READ >
MODE
< WRITE >
Set the
WRITE mode.
Move the cursor to the changed location with or
12
D 0
8 10
SP D 1 2 3
12
D 0
8 10
GO
15 - 30
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.11 Changing operands, set values
15.3.12 Deleting commands
Deletes one command at a time from a sequence program.
1
Operation
Stop the FX PLC
MODE
(DELETE mode)
Move the cursor to the command to be deleted.
GO
9
10
When moving the cursor to the position where the command is to be deleted.
Place the cursor on the command line (the line on which the step number is displayed).
You cannot delete the command if the cursor is placed on the line of an operand or set value.
D 0
D 10
12
Command line (Place the cursor on this line.)
Operand, set value line (Cannot operate on this line.)
11
12
2
Example
Deleting "OUT T10 K100".
Stop the FX PLC
13
< READ >
K 100
12 LD X 002
GO
MODE
<DELETE >
Set the
DELETE mode.
Move the cursor to the command to be
10 OR X 020Z1
13 AND D 1500.F
14
15
16
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.12 Deleting commands
15 - 31
15.3.13 Sequence program all clear
Clears all the sequence programs.
1
Operation
Stop the FX PLC
MODE
(WRITE mode)
NOP A GO
2
Example
Clears all the sequence programs.
Stop the FX PLC
< READ >
MODE
< WRITE >
Set the
WRITE mode.
NOP
0
2 M 100
12
A GO
! Caution
The program will be erased.
Press "OK" to continue.
OK Cancel
OK
Items cleared when All Clear for a sequence program is performed
When All Clear is executed, the parameters before program execution are initialized and Latch Clear is executed.
The memory space becomes the default value, the comment area a 0 block, the file register space a 0 block, and keywords unregistered.
After All Clear, set the above parameters etc. again.
15 - 32
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.13 Sequence program all clear
15.3.14 PLC diagnostics
Displays the FX PLC error message, error code, and step at which the error occurred.
1
Operation
OP
[PLC diagnostics]
GO
OP
Select [PLC diagnostics] with or
GO
13
2
PLC diagnostics screen
The following describes the contents displayed on the PLC diagnostics screen and the function of onscreen key.
(1) Displayed contents
14
No.
1)
2)
3)
Item
Error message
Detail
Step
15
1) 2) 3)
Display contents
Displays the error message. (I/O configuration error/PLC hardware error/PC/HPP communication error/Serial communication error/Parameter error/Syntax error/Circuit error/Operation error)
Displays the error code.
Displays the step number in the sequence program at which the error occurred.
(This is displayed only for a syntax error, circuit error, or operation error.)
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.14 PLC diagnostics
15 - 33
16
11
12
9
10
Remark
Error details
For details on an FX PLC error, refer to the manual below.
Programming manual for the FX CPU used
(2) Key functions
The table below shows the functions of the keys that are used for the operation on the PLC diagnostics screen.
Key Function
Exits the PLC diagnostics.
15 - 34
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.14 PLC diagnostics
15.3.15 Parameter setting
9
Sets FX PLC parameters.
1
Parameters that can be changed and change targets
(1) Parameters that can be changed
The parameters that can be changed with the MELSEC-FX list editor and the target FX PLCs are as follows.
( : Can be set/changed : Cannot be set/changed)
Target CPU
Item
FX0(S)
/FX0N
FX1 FX2(C) FX1S FX1N(C) FX2N(C) FX3G FX3U(C)
Memory space setting
File register space setting
*1
Latch range setting
*2 *2 *2
RUN terminal setting
Initialization of parameters
*1 When connecting an FX0(S), set "0".
Setting other than "0" causes a parameter error.
*2 When the parameters are initialized, the display on the MELSEC-FX list editor is different from the FX PLC default values, but do not change the latch range. Changing the latch range causes an error.
(2) Change targets
When a memory cassette is mounted, the parameters in the memory cassette are targeted for changes.
2
Operation
Stop the FX PLC
*1
OP [Parameter setting] GO
Stop the FX PLC
*1
10
11
12
13
OP
Select [Parameter setting] with or .
14
15
GO
*1 When checking parameters (not changing), it is not necessary to stop the PLC.
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.15 Parameter setting
15 - 35
16
3
Parameter setting screen
The following describes the contents displayed on the PLC diagnostics screen and the function of onscreen keys.
(1) Displayed contents
1)
2)
3)
4)
5)
No.
1)
Item
Memory capacity
2) File reg. capacity
3) Latch range
4)
5)
RUN terminal input
Default
Display contents
Sets the memory space (number of steps).
If you touch the *K section, you can change the memory space.
Sets the memory space (number of blocks) allocated to the file register.
Touch the section and input the number of blocks.
Sets the latch range (power failure hold area).
Touch the number display section and input the value.
Sets whether or not to use one of the FX PLC input terminals for RUN input.
Touch the section and set the device to be set for the RUN terminal.
Initializes the parameters
Memory space for kana comments after changing memory space, file register space
If the memory space is set smaller than the total of the file register space and kana comment space, the kana comment space is automatically reduced.
(With the MELSEC-FX list editor, the kana comment space is not displayed.)
Note that if any setting as described below is made, the kana comment space is reduced.
(Settings that reduce kana comment space and the kana comment space after setting change)
Settings resulting in Nm < Nf 500 + Nk 500 + 500
Kana comment space (steps) after setting change =
Nm - Nf x 500 - 500
500
Nm: Memory space after change (steps)
Nf: File register space after change (blocks)
Nk: Comment space before change (blocks)
Remark
Settable range and default value
The settable range and the default value depend on the FX PLC type.
Refer to the following manual for details of the settable range and the default value.
Programming manual for the FX PLC used
15 - 36
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.15 Parameter setting
(2) Key functions
The table below shows the functions of the keys that are used for the operation on the parameter setting screen.
Key Function
Initializes the parameters
9
10
Completes the changed setting contents.
Ends parameter setting.
11
12
13
14
15
16
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.15 Parameter setting
15 - 37
15.3.16 Keywords
Registers, deletes, releases protection for, and sets protection for the FX PLC keywords.
1
Function usability of the MELSEC-FX list editor for keyword protection levels
The functions that can be used with the MELSEC-FX list editor depend on the keyword protection level.
(
:
Available,
:
Unavailable)
Function
All operation protect
(All on-line operation protect)
*2
Keyword protection level
Read/Incorrect write protection (Read/write protect)
*2
Incorrect write protect
(Write protect)
*2
Keyword not registered/keyword protection canceled
Reference
Reading sequence programs
Writing sequence programs
Displaying sequence programs
Searching commands/ devices
Writing commands
Changing operands/set values
Inserting commands
Deleting commands
Sequence program all clear
PLC diagnostics
Parameter setting
*1
*1 When the 2nd keyword is set to an FX PLC that supports 2nd keyword, it becomes " " (cannot be used).
*2 The names within the parentheses ( ) are for when a keyword + 2nd keyword is set.
15 - 38
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.16 Keywords
2
Operation
OP
[Keyword setup]
GO
OP
Select [Keyword setup] with or .
GO
3
Keyword screen and protection level
When [Keyword setup] is selected with the MELSEC-FX list editor, the keyword screen is displayed.
Refer to the following manual for the procedure for keyword operations.
Remark
Keywords
Refer to the following manual for details of keyword.
Programming manual for the FX PLC used
13
14
15
16
11
12
9
10
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.16 Keywords
15 - 39
15.3.17 List monitor
The status of contacts and coils in a sequence program is displayed.
1
Operation
OP
[ List Monitor ]
GO
OP
Select [List Monitor] with or .
GO
When the list monitor is started on the FX list editor screen, the step numbers displayed on the FX list editor screen is displayed on the list monitor screen.
Starting list monitor with special function switches (FX list monitor)
With setting special function switches (FX list monitor), the list monitor can be started on the monitor screen.
When the list monitor is started on the monitor screen, the list editor cannot be used.
For how to set special function switches, refer to the following manual.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Functions)
15 - 40
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.17 List monitor
9
2
Displays and key functions
The following describes the displays for the list monitor.
3)
10
1)
2)
11
No.
1)
2)
Item
List display area
*1
Keys
3)
Display contents
The status of contacts and coils is displayed on the left of device displays.
The same operations as in the READ mode of the FX list editor can be executed.
(
SubSection 15.3.8 Sequence program display)
Ends the list monitor.
When the list monitor is executed on the FX list editor screen, the screen is switched to the FX list editor screen.
*1 The status of contacts and coils is displayed as below.
Type of instructio Description
LD, AND, OR(Contact instruction (Normal open)) Contact
LDI, ANI, ORI(Contact instruction (Normal close)) Contact
TC: Coil
OUT, SET
Except TC: Contact
TC: Reset
RST
Word device
Except TC and word device: Contac
Contact MC, STL
LDP, ANDP, ORP, LDF, ANDF, ORF
(Rise or fall contact instruction)
Not monitored
Displayed
ON
OFF
ON
ON
ON
Value: 0
Status
Not displayed
OFF
ON
OFF
OFF
OFF
Value: Except 0
OFF
ON
ON
OFF
Always not displayed
12
13
14
15
16
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.17 List monitor
15 - 41
15.3.18 Action for an incorrect key input
If an incorrect key is input, cancel the input contents.
1
Operation
(1) Before touching the
GO
key (before reading/writing the input contents)
Before touching the
GO
key, touch the CLR key.
(2) After touching the
GO
key (after reading/writing the input contents)
Write the command again. (
SubSection 15.3.10 Writing commands)
Commands finalized by writing and inserting operations are revised (overwritten) with the program writing.
15.3.19 Error Messages and Corrective Actions
This section describes the error messages displayed when the MELSEC-FX list editor is executed, and corrective action.
Error Messeage
Can not display while protected.
Can not operate while protected.
PLC parameter error.
Description
The all-operation protect, anti-plagiarism, or incorrect write protect keyword is set.
Corrective action
Check the protected operation.
Clear the keyword protection or delete the keyword.
PLC communications error.
An FX PLC parameter is defective.
The communication with the FX PLC is defective.
Set correct parameters in the FX PLC.
Check the FX PLC, cable, and GOT for abnormality.
Check whether the communication settings are correct or not.
PLC is running.
Can not write.
Step number is out of a range.
Not found.
Not found.
A writing operation etc. has been made while the FX PLC is running.
The memory to write to is EPROM.
The protect switch of the EEPROM is on.
The specified step number exceeded the maximum number.
The specified command cannot be found.
The specified device cannot be found.
Stop the FX PLC.
Set other than EPROM for the memory to write to.
Switch off the protect switch of the EEPROM.
Specify a step number below the maximum value.
Proceed to the next operation.
Step overflow.
The program may exceed the available space. (Writing is not executed.)
Proceed to the next operation.
Check the program memory space and delete commands to keep it within the space.
SubSection 15.3.12 Deleting commands
Command error.
An invalid command (non-existent command) was specified.
Input the correct command.
How to erase an error message
An error message is not erased even if the cause of the error is eliminated.
To erase an error message, touch a key on the MELSEC-FX list editor screen.
15 - 42
15.3 FX List Editor (For GT104[ ], GT105[ ] only)
15.3.18 Action for an incorrect key input
16. CLEANING OF DISPLAY SECTION
(CLEAN)
In utility, the screen can be set as not to be effected by touching the screen when clean with clothes.
For cleaning method, refer to "Section 18.3 Cleaning Method".
16.1 Clean
16.1.1 Display operation of clean
10
11
Main Menu
1
Touch [Clean] to bring up the setting window.
12
Touch [Clean].
Touch
For details of cleaning method, refer to the following.
2
Touching key closes the screen.
3
Even if touch points other than the upper left corner and upper right corner of the screen, the
GOT does not operates.
13
14
9
15
16
16.1 Clean
16.1.1 Display operation of clean
16 - 1
17. OS INSTALLATION
17.1 About the OS
GT10 is factory-installed with the BootOS, Standard monitor OS, and communication driver ([MELSEC-FX]).
Standard monitor OS is upgradeable from drawing software.
An installation of the communication driver is required when connected to a controller other than a MELSEC-FX.
(BootOS cannot be installed from drawing software.)
17.2 Standard monitor OS/
Communication Driver Installation
When installing the Standard monitor OS or communication driver, first bring up the OS installation screen on the GOT, and then install the communication driver from drawing software.
Model
GT1020
GT1030
GT104
GT105
(1) About the OS installation screen
The OS can be transferred from GT Designer2 or GT Designer3 without displaying the OS installation screen depending on the combination of the GOT and the standard monitor OS
BootOS version
BootOS version F or later
BootOS version F or later
Standard monitor OS
Standard monitor OS
From the first version
From the first version
[01.08.00]
GT Designer2
Version2.77F or later
GT Designer3
From the first version
Version2.90U or later
Version2.90U or later
For the installation using drawing software, refer to the following chapter.
GT Designer 2 Version Basic Operation/Data Transfer Manual
GT Designer 3 Version Screen Design Manual (Fundamentals)
(2) Checking method of BootOS, Standard monitor OS version
(a) Check the version of BootOS or Standard monitor OS installed in GOT at [OS information] of the utility.
Refer to the following for details.
(b) Check the version of BootOS installed in GOT at product shipment on the rating plate on GOT rear face.
GRAPHIC OPERATION TERMINAL
MODEL
GT1030-LBD
IN 20.4 26.4VDC POWER 2.2W MAX
SERIAL 710001 AA
MITSUBISHI ELECTRIC CORPORATION
MADE IN JAPAN
JY550D26301A
AA
BootOS Version
17 - 1
17.1 About the OS
1
Operation on the OS installation screen
1
Turn on the power while pressing and holding the bottom right corner of the screen.
17
18
Turn the GOT power on with the lower right corner touched.
2
The OS installation screen will appear.
3
Install the Standard monitor OS and communication driver from drawing software.
Refer to the chapter below for how to install the
Standard monitor OS and communication driver from drawing software.
GT Designer2 Version
Basic Operation/Data Transfer Manual
GT Designer3 Version
Screen Design Manual (Fundamentals)
4
At the completion of Standard monitor OS/ communication driver installation, the GOT reboots itself and the user-created screen will appear.
If no project data exist, a dialog will appear indicating that no project data exist.
Checking the communication driver version
Some versions of the Standard monitor OS and communication driver may not be compatible with each other, and the communication driver may not function properly.
(e.g., The version of the Standard monitor OS is too old to recognize the newer version of the communication driver.)
The Standard monitor OS checks the version of the communication driver to see if it is compatible. If it is not compatible, a dialog that recommends Standard monitor OS update will appear.
Touching the
OK
button will take the screen back to the utility display screen.
Normal operation of the unit will require an update of the Standard monitor OS.
17.2 Standard monitor OS/ Communication Driver Installation
17 - 2
17.3 Standard Monitor OS/Communication
Driver Installation Using Memory Board
The memory board can be used only for GT104 , GT105 .
There are the following two types for the standard monitor OS, communication driver installation using memory board.
(1) Installation method when the GOT is turned on
When the GOT is turned on, all the OS and project data stored in the memory board are transferred to the GOT.
(2) Installation using GT10-50FMB function (utility)
Select OS or project data stored in the memory board, and then transfer it to the GOT using the utility function.
For details of GT10-50FMB function, refer to the following.
17.3.1 Installation method when the GOT is turned on
1
Operation procedure
1
Power OFF the GOT, and attach the memory board which stores the standard OS and communication driver to the GOT.
2
While touching the upper left corner and lower left corner of the GOT screen, power ON the
GOT.
3
The screen on the left is displayed.
Touch the [OK] button to start the installation, and [CANCEL] for the cancellation.
4
The dialog box on the left is displayed for confirmation.
Touch [YES] button to start the installation, and
[NO] to abord.
17 - 3
17.3 Standard Monitor OS/Communication Driver Installation Using Memory Board
17.3.1 Installation method when the GOT is turned on
5
While the installation is executed, the dialog box on the left is displayed.
17
6
Installation is completed.
Touch the ESC button to restart the GOT and displays the user-created to screen.
(If the project data does not exist, a message appears to notify that the project data does not exist.)
If an error occurs during copy, an error message appears.
For details of error messages, refer to the following.
18
17.3 Standard Monitor OS/Communication Driver Installation Using Memory Board
17.3.1 Installation method when the GOT is turned on
17 - 4
18. MAINTENANCE AND INSPECTION
STARTUP AND MAINTENANCE
PRECAUTIONS
DANGER
When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
Connect the battery correctly.
Do not discharge, disassemble, heat, short, solder or throw the battery into the fire.
Incorrect handling may cause the battery to generate heat, burst or take fire, resulting in injuries or fires.
Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases.
Not switching the power off in all phases can cause a unit failure or malfunction.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
STARTUP AND MAINTENANCE
PRECAUTIONS
CAUTION
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull the cable portion.
Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.
Do not drop or apply any impact to the battery.
If any impact has been applied, discard the battery and never use it.
The battery may be damaged by the drop or impact.
Before touching the unit, always touch grounded metal, etc. to discharge static electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
DISPOSAL PRECAUTIONS
CAUTION
When disposing of the product, handle it as industrial waste.
The GOT does not include consumable components that will cause the shorten life.
However, the battery(For GT1030, GT104 , GT105 ), liquid crystal screen and backlight(For GT105 ) has life length.
(For the replacement of the liquid crystal screen, please consult your nearest sales office or FA center.)
For the battery, refer to the following.
Section 3.2 Performance Specifications
For the life of the LCD screen or backlight, refer to the following.
Section 3.2 Performance Specifications
18 - 1
18.1 Daily Inspection
17
Daily inspection items
No.
1
Inspection Item
GOT mounting status
Inspection
Method
Check for loose mounting screws.
Retighten screws with screwdriver
Criterion
Securely mounted
Action
Retighten screws within the specified torque range
2
Connection status
Loose terminal screws
Loose connectors Visual check
Not loose
Not loose
Retighten terminal screws
Retighten connector fixing screws
Replace with new one
3
Usage status
Dirt on protection sheet Visual check
Foreign material attachment
Visual check
Not outstanding
No foreign matter sticking
Remove clean
Refer to the following for the model names of the protection sheet or the replacement procedure.
18.2 Periodic Inspection
Yearly or half-yearly inspection items
The following inspection should also be performed when equipment has been moved or modified or the wiring changed.
No.
Inspection Item Inspection Method Action
1
Surrounding environment
Ambient temperature
Ambient humidity
Atmosphere
Make measurement with thermometer or hygrometer
Measure corrosive gas
Criterion
Display section 0 to 50°C
Other portions 0 to 55°C
10 to 90%RH
No corrosive gas
For use in control panel, temperature inside control panel is ambient temperature
2 Power supply voltage check
24VDC Measure voltage across terminals.
Move module
20.4 to 26.4VDC
Change supply power
3
4
Mounting status
Connection status
Looseness
Dirt, foreign matter
Loose terminal screws
Loose connectors
Visual check
Retighten screws with screwdriver
Visual check
Should be mounted firmly Retighten screws
No dirt, foreign matter sticking
Remove, clean
Not loose
Not loose
Retighten terminal screws
Retighten connector fixing screws
5 Battery
Check the "Battery voltage" by using the
"Time setting" function in the utility.
(Preventive maintenance)
Replace with new battery when the current battery has reached the specified life span, even if battery voltage is not displayed.
18
18.1 Daily Inspection
18 - 2
18.3 Cleaning Method
Use the GOT always in a clean condition.
To clean the GOT, wipe the dirty part with a soft cloth using neutral detergent.
For the display operation of the [Clean] screen, refer to the following.
Chapter 16 CLEANING OF DISPLAY SECTION (CLEAN)
Precautions for cleaning
Do not use chemicals such as thinner, organic solvents and strong acids, since they may cause the protective sheet to be deformed or the dissolvable paint on the surface to peel off.
In addition, do not use spray solvents since they may cause the electrical failure of the GOT and peripheral devices.
18 - 3
18.3 Cleaning Method
18.4 Battery Voltage Low Detection and Battery
Replacement
17
1
Low battery voltage detection and replacement
The battery (For GT1030, GT104 , GT105 ) is used for backing up the clock data, alarm history or recipe data.
It is recommended that you replace battery periodically.
Refer to the following for the replacement procedure.
The battery voltage low detection can be confirmed by the utility screen and system alarm.
Refer to the following for details of the battery status display by the utility screen.
Chapter 13 CLOCK SETTINGS AND BATTERY STATUS DISPLAY (TIME SETTING
18
Battery replacement timing
When detecting voltage low, replace the battery immediately.
Data can be saved for approximately a month after the battery voltage low detection and cannot be saved after that.
If it exceeds a month from the voltage low detection to battery replacement, the clock data or D-drive* (Internal SRAM) data may become indefinite.
Adjust the clock and format the D drive (Internal SRAM).
* : GT1020 does not have D drive.
Example of alarm output to external device (lamp, buzzer, etc.)[For GT1030, GT104 ,
GT105 ]
The following describes an example of outputting the battery voltage low signal from a FX series PLC to an external device with system information.
Condition: The Write Device is "D20" and all data is used (the
Select All
button is clicked on the setting screen of drawing software) for the system information assignment.
D36 b12: Battery voltage low (System Signal 2-2)
Turned on upon a battery voltage drop.
Used as shown below in the sequence program.
RUN monitor
M8000
MOV D36 K4M20
Battery voltage low
M32
Y***
Output to external device of PLC
Activated the output upon battery voltage low detection.
"*" indicates the output number at which the external device is connected.
For details of system information, refer to the following.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
18.4 Battery Voltage Low Detection and Battery Replacement
18 - 4
2
Handling of Batteries and Devices with Built-in Batteries in EU Member States
This section describes the precautions for disposing of waste batteries in EU member states and exporting batteries and/or devices with built-in batteries to EU member states.
(1) Disposal precautions
In EU member states, there is a separate collection system for waste batteries. Dispose of batteries properly at the local community waste collection/recycling center.
The following symbol is printed on the batteries and packaging of batteries and devices with built-in batteries used for Mitsubishi Graphic Operation Terminal (GOT).
Symbol
This symbol is for EU member states only.
The symbol is specified in the new EU Battery Directive (2006/66/EC) Article 20
"Information for end-users" and Annex II.
The symbol indicates that batteries need to be disposed of separately from other wastes.
(2) Exportation precautions
The new EU Battery Directive (2006/66/EC) requires the follwoing when marketing or exporting batteries and/or devices with built-in batteries to EU member states.
• To print the symbol on batteries, devices, or their packaging
• To explain the symbol in the manuals of the products
(a) Labelling
To market or export batteries and/or devices with built-in batteries, which have no symbol, to
EU member states on September 26, 2008 or later, print the symbol shown in (1) on the GOT
or their packaging.
(b) Explaining the symbol in the manuals
To export devices incorporating Mitsubishi Graphic Operation Terminal to EU member states on September 26, 2008 or later, provide the latest manuals that include the explanation of the symbol.
If no Mitsubishi manuals or any old manuals without the explanation of the symbol are provided, separately attach an explanatory note regarding the symbol to each manual of the devices.
Remark
The requirements apply to batteries and/or devices with built-in batteries manufactured before the enforcement date of the new EU Battery Directive(2006/66/EC).
18 - 5
18.4 Battery Voltage Low Detection and Battery Replacement
18.5 Backlight Shutoff Detection
17
The backlight is built into GOT(For GT105 ) for the liquid crystal display.
When GOT(For GT105 ) detects backlight shutoff, the POWER LED blinks green/orange alternately.
The brightness of the backlight decreases with the lapse of usage period. When backlight shutoff is detected or the display becomes unclear, replace the backlight.
For replacement of the backlight, contact your nearest sales office or FA Center.
(1) Life of backlight
The usable duration of backlight can be extended by setting to "Screen saving backlight off" in the utility of GOT (GOT set up).
Refer to the following for details.
Chapter 12 DISPLAY AND OPERATION SETTINGS (GOT SET UP)
18
18.5.1 Backlight shutoff detection and external alarm
When the GOT(For GT105 ) detects a backlight shutoff, the system information set with drawing software is turned on.
You can issue a backlight shutoff of the GOT from the PLC to external devices (such as the lamp or buzzer), using system information.
To avoid any screen touch operation by the user who misunderstands it is in screen saving mode, install an external alarm and interlock the loads that would cause danger.
For details of the system information, refer to the following.
GT Designer2 Version Screen Design Manual
GT Designer3 Version Screen Design Manual (Fundamentals)
Example of alarm output to external devices (such as lamp or buzzer)
The following provides an example of outputting the backlight shutoff detection signal from a FX Series PLC to an external device, using system information.
Condition: The Written Device is "D20" and all data is used (the
Select All
button is clicked on the setting screen of drawing software) for the system information assignment.
D36 b14: Backlight shutoff detection (System Signal 2-2)
Turned on upon a backlight shutoff.
Used as shown below in the sequence program.
RUN monitor
M8000
MOV D36 K4M20
Backlight shutoff detection
M34
Y***
Output to external device of PLC
Activated the output upon battery shutoff detection.
"*" indicates the output number at which the external device is connected.
Precautions for the backlight shutoff status
In the backlight shutoff status, the touch key operates.
18.5 Backlight Shutoff Detection
18.5.1 Backlight shutoff detection and external alarm
18 - 6
APPENDICES
Appendix 1 External Dimensions
External dimensions of GT1020
113(4.44")
10
(0.39")
76(2.99")
10
(0.39")
5
(0.19")
7.5
(0.29")
MITSUBISHI
GOT
1000
80(3.14") or more
10
(0.39")
76(2.99")
10
(0.39")
9.5
(0.37")
Panel thickness: 1 to 4mm
(0.03" to 0.15")
Unit: mm(inch)
App - 1
Appendix 1 External Dimensions
External dimensions of GT1030
10 (0.39")
145 (5.7")
84 (3.3") 10 (0.39")
MITSUBISHI
GOT
1000
4.5
(0.17")
80(3.14") or more
17
18
10
(0.39")
84 (3.3") 10 21
(0.39") (0.82")
Panel thickness: 1 to 4mm
(0.03" to 0.15")
Unit: mm (inch)
Appendix 1 External Dimensions
App - 2
External dimensions of GT104
10
(0.39")
139(5.47")
86(3.38")
MITSUBISHI
GOT
1000
10
(0.39")
15.5
(0.61")
#4-40UNC
(Inch screw type)
M2.6
(Metric screw type)
10
(0.39")
86(3.38")
10 17.5
(0.39") (0.68")
Panel thickness: 5mm(0.2") or less
129(5.07")
Memory board connected
Unit: mm(inch)
App - 3
Appendix 1 External Dimensions
External dimensions of GT105
22
(0.87")
23(0.91")
164(6.46")
120(4.73")
22
(0.87")
120(4.73")
152(5.99")
Memory board connected
17
#4-40UNC
(Inch screw type)
M2.6
(Metric screw type)
18
Panel thickness: 5mm(0.2") or less
Unit: mm(inch)
Appendix 1 External Dimensions
App - 4
External dimensions of communication cable
GT10-C R4-8P
30(1.18")
L
40(1.57")
250(9.84")
Model name
GT10-C10R4-8P
GT10-C30R4-8P
GT10-C100R4-8P
GT10-C200R4-8P
GT10-C300R4-8P
φ13(0.51")
φ7(0.27") φ25 33(0.98" 1.29")
Remarks
Unit: mm(inch)
L (mm (inch))
1,000 (39.37")
3,000 (118.11")
10,000 (393.7")
20,000 (787.4")
30,000 (1181.1")
RS-422 cable for direct connection to FXCPU (8-pin MINI-DIN)
GT10-C R4-25P
30(1.18")
L
53(2.08")
16(0.62")
250(9.84")
φ7(0.27") φ25 33(0.98" 1.29")
Remarks
Unit: mm(inch)
55
(2.16")
Model name
GT10-C30R4-25P
GT10-C100R4-25P
GT10-C200R4-25P
GT10-C300R4-25P
L (mm (inch))
3,000 (118.11")
10,000 (393.7")
20,000 (787.4")
30,000 (1181.1")
RS-422 cable for direct connection to FXCPU and A/QnACPU
(25-pin D-sub)
GT10-C30R2-6P
30(1.18") 3000(118.11") 40(1.57")
App - 5
Model name
GT10-C30R2-6P
L (mm (inch))
3,000 (118.11")
Appendix 1 External Dimensions
200(7.87")
Approx.
φ30(1.18")
φ13(0.51")
Approx. 48(1.88")
φ7(0.27")
Unit: mm(inch)
Remarks
RS-232 cable for direct connection to QCPU (6-pin MINI-DIN)
17
GT10-C10R4-8PL
30(1.18") 1000(39.37")
250(9.84")
38(1.49")
Model name
GT10-C10R4-8PL
L (mm (inch))
1,000 (39.37")
30
(1.18")
φ7(0.27") φ25 33(0.98" 1.29")
φ13
(0.51")
Unit: mm(inch)
Remarks
RS-422 cable for direct connection to FXCPU (8-pin MINI-DIN)
GT01-C30R4-25P
16
(0.63")
50(1.97")
Model name
GT01-C30R4-25P
30000(1181.1") 53(2.09")
16
(0.63")
7
(0.28")
M2.6
L (mm (inch))
3,000 (118.11")
M2.6
Unit: mm(inch)
Remarks
RS-422 cable for direct connection to FXCPU and A/QnACPU
(25-pin D-sub)
GT01-C R4-25P
16
(0.63")
50(1.97")
Model name
GT01-C100R4-25P
GT01-C200R4-25P
GT01-C300R4-25P
L 53(2.09")
16
(0.63")
7
(0.28")
M2.6
L (mm (inch))
10,000 (393.7")
20,000 (787.4")
30,000 (1181.1")
M2.6
Unit: mm(inch)
Remarks
RS-422 cable for direct connection to FXCPU and A/QnACPU
(25-pin D-sub)
18
Appendix 1 External Dimensions
App - 6
GT01-C R4-8P
16
(0.63")
50(1.97")
Model name
GT01-C10R4-8P
GT01-C300R4-8P
GT01-C100R4-8P
GT01-C200R4-8P
GT01-C300R4-8P
L
6
(0.24")
25 33
(0.99") (1.3")
40(1.58")
13
(0.52")
M2.6
Unit: mm(inch)
L (mm (inch))
1,000 (39.37")
3,000 (118.11")
10,000 (393.7")
20,000 (787.4")
30,000 (1181.1")
Remarks
RS-422 cable for direct connection to FXCPU (8-pin MINI-DIN)
GT01-C30R2-25P
16
(0.63")
50(1.97")
Model name
GT01-C30R2-25P
30000(1181.1") 53(2.09")
16
(0.63")
6
#4-40UNC
L (mm (inch))
3,000 (118.11")
M2.6
Unit: mm(inch)
Remarks
RS-232 cable for direct connection to FXCPU special adaptor
(25-pin D-sub)
GT01-C30R2-9S
16
(0.63")
50(1.97")
Model name
GT01-C30R2-9
30000(1181.1")
6
50(1.97")
16
(0.63")
#4-40UNC
L (mm (inch))
3,000 (118.11")
#4-40UNC
Unit: mm(inch)
Remarks
RS-232 cable for direct connection to FXCPU expansion board
(9-pin D-sub)
App - 7
Appendix 1 External Dimensions
GT01-C30R2-6P
16
(0.63")
Model name
GT01-C30R2-6P
50(1.97") 30000(1181.1")
20 28
(0.79") (1.11")
7
(0.28")
40(1.58")
13
(0.52")
L (mm (inch))
3,000 (118.11")
#4-40UNC
Unit: mm(inch)
Remarks
RS-232 cable for direct connection to QCPU (6-pin MINI-DIN)
17
18
Appendix 1 External Dimensions
App - 8
External dimensions of RS-232/USB conversion adaptor
GT10-RS2TUSB-5S
40(1.57") 200(7.87") 75(2.95")
External dimensions of GT10-LDR memory loader
Unit : mm(inch)
Weight : Approx. 40g
70 (2.75")
14
(0.55")
240 (9.44")
Unit: mm (inch)
Weight: 0.2kg
App - 9
Appendix 1 External Dimensions
External dimensions of memory board
19(0.75")
35(1.38")
20(0.79")
11
(0.44")
External dimensions of debug stand
For angle of 75
Unit: mm (inch)
153(6.05")
220(8.67")
260(10.24")
External dimensions of serial multi-drop connection unit
Unit: mm (inch)
17
18
2- 4.5
57(2.25")
65(2.56")
External dimensions of connector conversion adapter
80(3.15")
Unit: mm (inch)
36(1.42") 22
(0.87")
Unit: mm (inch)
Appendix 1 External Dimensions
App - 10
Appendix 2 Usage Condition of Utility Function
Different functions are available on the GOT and drawing software.
Setting items Function GT1020 GT1030
: Applicable : N/A
GT104
GT105
Drawing
Setting
(GT
Designer2,
GT
Designer3)
Language
Standard I/F
Data Transfer
Communication
Monitor
Keyword
Display bright/contrast
Operation
Key reaction
Clock setting
Security
*1
Utility call
Time setting
OS information
Font data
Clear data
GT10-50FMB
Device monitor
FX list editor
Message language switching (Japanese/
English)
Detailed settings for the channel number and communication driver of the communication interface
Communication parameter display
Displays the screen for transferring project data between the PC and GOT
Displays the status of the communication ports
Setting related to a keyword of FX series
PLC
Screen save time setting
Screen save backlight ON/OFF setting
Opening time setting
Liquid crystal brightness setting
Liquid crystal contrast setting
Buzzer volume setting
Correcting touch position reading error
Key reaction display
Setup the method to adjust the time between
GOT clock data and clock data of PLC CPU connected with GOT
Security level change
(security password input of each object)
Setting of the menu call key
Displaying the present time of the clock
Setting the present time of the clock
Displaying the battery status
Displays the version of the OS (Standard monitor OS, BootOS) and communication driver versions
Displays the font type
Deletes project data and resource data
Data transfer using a memory board
Device monitor of PLC of intelligent module
List editing PLC program of FX PLC
App - 11
Appendix 2 Usage Condition of Utility Function
Setting items Function ean Clean
Display the screen to clean the display section
*1: It is necessary to set the security level with drawing software.
GT1020 GT1030
GT104
GT105
Drawing
Setting
(GT
Designer2,
GT
Designer3)
17
18
Appendix 2 Usage Condition of Utility Function
App - 12
Appendix 3 Transportation Precautions
When transporting lithium batteries, make sure to treat them based on the transport regulations.
Appendix 3.1 Relevant models
The battery for the GOT1000 Series is classified as shown in the table below.
Product name
Battery for GOT1000 Series
Model
GT11-50BAT
Description
Lithium coin battery
Handled as
Non-dangerous goods
Appendix 3.2 Transport guidelines
Products are packed properly in compliance with the transportation regulations prior to shipment. When repacking any of the unpacked products to transport it to another location, make sure to observe the IATA
Dangerous Goods Regulations, IMDG Code and other local transportation regulations.
For details, please consult your transportation company.
App - 13
Appendix 3 Transportation Precautions
Appendix 4 List of Functions Added by GT Designer2
Version Upgrade (For GOT1000 Series)
17
The following describes the functions added by version upgrade of the GT Designer2 Version2.98C.
For function comparisons among GOTs, refer to the following.
GT Designer2 Version Basic Operation/Data Transfer Manual
(Appendix 3.2 List of Differences between the GOT1000 series and GOT-900 series
functions)
For using the following functions, use GT Designer2 or OS of the corresponding version or later.
How to use this table
1
provides the versions of GT Designer2 and OS required for each GOT or communication unit.
and the following provides description for the functions added with the version upgrade, and the versions of GT Designer2 and OS with which the function is compatible.
Regarding and the following, there may be a case where the function is not supported by a particular type of GOT even when the function is compatible with the version.
In such a case, check the version for the function and the version of the GOT, and use GT Designer2 or OS of the later version.
Appendix 4.1 For GT10
GT Designer2 Version 2.43V or later is applicable to GT1020.
GT Designer2 Version 2.58L or later is applicable to GT1030.
GT Designer2 Version 2.90U or later is applicable to GT105 .
GT Designer2 Version 2.90U or later is applicable to GT104 .
1
Added GOT main unit
Target Models
GT1020-LBD/LWD, GT1020-LBD2/LWD2, GT1020-LBL/LWL
GT1020-LBDW/LWDW, GT1020-LBDW2/LWDW2, GT1020-LBLW/LWLW
GT1030-LBD/LWD, GT1030-LBD2/LWD2 , GT1030-LBDW/LWDW,
GT1030-LBDW2/LWDW2
GT1055-QSBD, GT1050-QBBD
GT1045-QSBD, GT1040-QBBD
GT1030-LBL/LWL, GT1030-LBLW/LWLW
Version of GT
Designer2
2.43V
2.58L
2.58L
2.90U
2.90U
2.97B
Version of OS
-
-
-
-
-
-
18
Appendix 4 List of Functions Added by GT Designer2 Version Upgrade
(For GOT1000 Series)
App - 14
2
Added connection types
Item
Direct connection to
CPU
Computer link connection
CC-Link connection (Via
G4)
Supporting connection to CC-Link (Via G4)
GOT multidrop connection
Microcomputer connection
MODBUS /
RTU connection
Supporting MODBUS /RTU connection
OMRON PLC connection
Description
Supporting connection to FX3G series
Supporting connection to A series PLC
Supporting the GOT multidrop connection
Supporting the data formats of Format 1 and
Format 2.
Supporting connection to OMRON PLC
KEYENCE PLC connection
Supporting connection to KEYENCE PLC
Supporting connection to KV-3000 and KV-5000
: Applicable : N/A - : Applicable (from the first version)
Version of GT
Designer2
2.90U
2.82L
2.73B
2.96A
2.47Z
2.96A
2.47Z
2.73B
2.77F
Version of OS
GT
105 /
104
GT
1030
GT
1020
Standard monitor OS [01.10.**]
Communication driver
MELSEC-FX[01.06.**]
Standard monitor OS [01.09.**]
Communication driver
AJ71C24/UC24[01.04.**]
Standard monitor OS [01.07.**]
Communication driver
CC-Link(G4)
[01.00.**]
Standard monitor OS [01.11.**]
Communication driver
Multidrop(Host) [01.11.**]
Multidrop(Slave) [01.11.**]
Standard monitor OS [01.02.**]
Communication driver
Computer
[01.02.**]
Standard monitor OS [01.12.**]
MODBUS/ RTU
[01.07.**]
-
-
-
Standard monitor OS [01.02.**]
Communication driver
OMRON SYSMAC [01.02.**]
-
Standard monitor OS [01.07.**]
Communication driver
KEYENCE KV-700/1000[01.00.**]
-
Communication driver
KEYENCE KV700/1000 [01.03.**]
-
(Continued to next page)
App - 15
Appendix 4 List of Functions Added by GT Designer2 Version Upgrade
(For GOT1000 Series)
Item
TOSHIBA
MACHINE PLC connection
PANASONIC
PLC connection
YASKAWA PLC connection
Supporting connection to CP9200SH/MP900 series
Supporting connection to MP2000/MP900 series
LS IS PLC connection
ALLEN-
BRADLEY PLC connection
Supporting connection to MicroLogix 1000/1200/
1500 series.
Supporting connection to SLC500 series.
SIEMENS PLC connection
Supporting connection to SIEMENS S7-200 series.
Supporting connection to SIEMENS S7-300/400 series
Inverter connection
Servo amplifier connection
Bar code reader connection
Description
Supporting connection to TOSHIBA MACHINE
PLC
Supporting connection to PANASONIC PLC
Communication driver name has been changed.
Supporting connection to LS IS PLC
Supporting connection to inverter
Supporting connection to MR-J2S-*CL
Supporting connection to barcode reader
Version of GT
Designer2
2.77F
2.73B
2.96A
2.73B
2.73B
2.90U
2.58L
2.58L
2.58L
2.90U
2.73B
2.96A
2.77F
Version of OS
Communication driver
TOSHIBA MACHINE TCmini
[01.03.**]
Standard monitor OS [01.07.**]
Communication driver
MATSUSHITA MEWNET-FP
[01.00.**]
Standard monitor OS [01.12.**]
Communication driver
Panasonic MEWNET-FP
[01.07.**]
Standard monitor OS [01.07.**]
Communication driver
YASKAWA MP [01.00.**]
Standard monitor OS [01.07.**]
Communication driver
LS Industrial Systems MASTER-K
[01.05.**]
Standard monitor OS [01.04.**]
Communication driver
AB MicroLogix [01.00.**]
Standard monitor OS [01.04.**]
Communication driver
AB SLC 500 [01.00.**]
Standard monitor OS [01.04.**]
Communication driver
SIEMENS S7-200 [01.00.**]
Standard monitor OS [01.10.**]
Communication driver
SIEMENS S7-300/400 [01.05.**]
Standard monitor OS [01.07.**]
Communication driver
FREQROL 500/700 [01.00.**]
Standard monitor OS [01.12.**]
Communication driver
MELSERVO-J3, J2S/M [01.07.**]
Standard monitor OS [01.08.**]
GT
105 /
104
GT
1030
GT
1020
-
-
-
-
-
-
-
-
-
17
18
Appendix 4 List of Functions Added by GT Designer2 Version Upgrade
(For GOT1000 Series)
App - 16
3
Added GT Designer2 functions
Item Description
Library workspace
Project data matching
Screen preview
Enables setting the background color of the figures in the Library Editor screen.
Project data matching is available between data stored in the personal computer and data opened with GT Designer2.
Enables switching screens in the Screen
Preview window.
Enables setting [Specify the touch area.].
Auxiliary setting
Reading BMP or
JPEG image data
Directly editing comment group
For the set overlay screen function, the setting to place the called screen under the basic screen is added.
For the set overlay screen function, the setting to disable the background color of the called screen is added.
Enables displaying BMP or JPEG image data reduced to a resolution of 2000 1600 or less on GT Designer2.
Enables editing the comment group directly in settings for the lamps and touch switches.
Version of GT
Designer2
2.47Z
2.96A
2.96A
2.77F
2.96A
2.77F
2.77F
Version of OS
-
-
-
-
-
-
-
GT
105 /
104
GT
1030
GT
1020
-
-
-
-
4
Added common settings/object functions
Item Description
Figure
Standard font
TrueType font
Window screen
GOT internal device
GOT Setup
Supporting piping
Enables displaying BMP or JPEG image data reduced to a resolution of 2000 1600 or less on GT Designer2.
Supporting logo text
Supporting Japanese
Supporting Japanese (supporting Europe)
Supporting Chinese (Simplified)(supporting
Europe)
Supporting Chinese (Traditional)(supporting
Europe)
Supporting the TrueType numerical font (Gothic)
Supporting the TrueType numerical font
(7-segment)
Corresponding to the overlap window display and the superimpose display.
Devices from GS0 to GS1023 are available.
The key reaction speed can be set.
Version of GT
Designer2
2.73B
Version of OS
Standard monitor OS [01.00.**]
2.77F
Supported soon
2.91V
2.91V
2.73B
2.96A
2.82L
Standard monitor OS [01.08.**]
Standard monitor OS [01.12.**]
Standard monitor OS [01.11.**]
Standard monitor OS [01.11.**]
BootOS [01.11.**.G]
Standard monitor OS [01.11.**]
Standard monitor OS [01.07.**]
Standard monitor OS [01.12.**]
GT
105 /
104
-
GT
1030
GT
1020
-
-
Standard monitor OS [01.09.**] -
(Continued to next page)
App - 17
Appendix 4 List of Functions Added by GT Designer2 Version Upgrade
(For GOT1000 Series)
Item Description
Clock function
Numerical
Display/
Numerical input
ASCII input
The clock data storage to the GD device is possible.
Format String setting is possible.
Enables setting the asterisk display.
The ASCII input can be set.
Enables setting the asterisk display.
Comment
Display
Lamp Display
The simple comment is added.
Touch switch
Graph
Alarm history display
[Comment Group] can be used.
Auto repeat can be used.
[Comment Group] can be used.
The device monitor and debug function can be set for the action setting of the special function switch and the multi action switch.
The statistics bar graph can be set.
The statistics pie graph can be set.
Enables selecting whether to set the scrolling comment display suitable for the message display area.
Comment group can be used.
Scrolling alarm display
The scrolling alarm display applicable
Version of GT
Designer2
2.73B
2.73B
2.73B
2.77F
2.96A
2.58L
2.96A
2.77F
2.77F
2.73B
2.77F
2.82L
2.58L
2.58L
2.63R
Version of OS
Standard monitor OS [01.07.**]
Standard monitor OS [01.08.**]
Standard monitor OS [01.12.**]
Standard monitor OS [01.03.**]
Standard monitor OS [01.12.**]
Standard monitor OS [01.08.**]
Standard monitor OS [01.08.**]
Standard monitor OS [01.07.**]
Standard monitor OS [01.08.**]
Standard monitor OS [01.09.**]
Standard monitor OS [01.03.**]
Standard monitor OS [01.03.**]
Standard monitor OS [01.06.**]
Standard monitor OS [01.07.**]
Standard monitor OS [01.07.**]
5
Other functions added
Item Description
Installing OS
Installing/ uploading with
GT10-LDR
MELSEC-FX list editor function
Enables installing the OS without the OS installation screen of the GOT.
Enables installing or uploading the OS, communication drivers, project data, and others with the GT10-LDR.
Enables installing the OS for the GT10-LDR.
Supporting the following fonts when the OS is installed.
Japanese
Chinese (Simplified)(supporting Europe)
Chinese (Traditional)(supporting Europe)
TrueType numerical font (7-segment)
TrueType numerical font (Gothic)
Function to display or edit a sequence program read from the FXCPU in the list mode
Version of GT
Designer2
2.77F
Version of OS
Standard monitor OS [01.08.**]
2.77F
2.91V
2.90U
-
Standard monitor OS [01.11.**]
-
GT
105 /
104
GT
1030
GT
1020
-
-
-
-
-
-
-
-
-
-
-
GT
105 /
104
GT
1030
GT
1020
-
-
-
-
-
17
18
Appendix 4 List of Functions Added by GT Designer2 Version Upgrade
(For GOT1000 Series)
App - 18
MEMO
App - 19
Appendix 4 List of Functions Added by GT Designer2 Version Upgrade
(For GOT1000 Series)
INDEX
17
[B]
..................................................... 2-1,2-2,2-11
..................................................4-8,4-9,8-9,18-4
....................................................... 12-10
[C]
...................................................................... 16-1
................................................... 18-3
.................................................. 12-14,13-1
.......................................... 11-15
................................... 11-2
........................................................... 2-3
....................... 2-1,2-2,8-24
.................................................................. 12-6
[D]
....................................................... 18-2
..................................................................... 15-1
......................................................... 15-1
......................................... 14-2
....................................................... 12-2
[E]
............................................... App-1
[F]
................................................................... 1-4
.............................................................. 14-1
[G]
................................................ 3-1
............................................................. 12-1
[I]
................................................................. 6-1
[K]
.......................................................... 12-13
................................................................ 11-18
[M]
MELSEC-FX LIST EDITOR
Action for an incorrect key input..................... 15-42
Changing operands, set values ..................... 15-30
Deleting commands ....................................... 15-31
Display ........................................................... 15-18
Error Messages and Corrective Actions ........ 15-42
Key arrangement and a list of key functions .. 15-20
Keywords ....................................................... 15-38
List monitor .................................................... 15-40
Operation Procedures.................................... 15-20
Parameter setting........................................... 15-35
PLC diagnostics ............................................. 15-33
Searching commands and devices ................ 15-25
Selection and operation of modes.................. 15-22
Sequence program all clear ........................... 15-32
Sequence program display ............................ 15-23
Specifications ................................................. 15-15
System configuration...................................... 15-15
Writing commands ......................................... 15-27
...........................................2-2,8-16,14-7
.............................................2-1,2-2,8-12
[O]
........................................................... 12-7
...................................................... 12-9
................................................................. 2-6,8-1
......................................................... 17-1
................................................... 2-1
[P]
............................................ 6-6
................................................................. 4-1
......................................... 3-2
................................................... 18-2
....................................... 3-14
.....................................2-1,2-2,8-1,18-2
[R]
................................... 1-5
............................................................. 2-6
............................................................. 2-6
[S]
................................................................. 12-15
Serial multi-drop connection unit
....................2-1,2-2,8-21
..................................................................... 12-1
............................................................ 3-1
General specifications........................................ 3-1
Performance specifications ................................ 3-2
Power supply specifications ............................. 3-14
........................................ 14-2,17-1
........................................................... 18-4
.................................................. 2-1
[T]
........................................... 13-1
[U]
............................................................... 12-16
............................................................. 9-3
....................................................... 9-1
[W]
....................................................................... 7-1
Index-1
18
MEMO
Index-2
WARRANTY
Please confirm the following product warranty details before using this product.
1. Gratis Warranty Term and Gratis Warranty Range
If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the sales representative or Mitsubishi Service Company.
However, if repairs are required onsite at domestic or overseas location, expenses to send an engineer will be solely at the customer's discretion. Mitsubishi shall not be held responsible for any re-commissioning, maintenance, or testing on-site that involves replacement of the failed module.
[Gratis Warranty Term]
The gratis warranty term of the product shall be for one year after the date of purchase or delivery to a designated place. Note that after manufacture and shipment from Mitsubishi, the maximum distribution period shall be six (6) months, and the longest gratis warranty term after manufacturing shall be eighteen (18) months. The gratis warranty term of repair parts shall not exceed the gratis warranty term before repairs.
[Gratis Warranty Range]
(1) The range shall be limited to normal use within the usage state, usage methods and usage environment, etc., which follow the conditions and precautions, etc., given in the instruction manual, user's manual and caution labels on the product.
(2) Even within the gratis warranty term, repairs shall be charged for in the following cases.
1. Failure occurring from inappropriate storage or handling, carelessness or negligence by the user. Failure caused by the user's hardware or software design.
2. Failure caused by unapproved modifications, etc., to the product by the user.
3. When the Mitsubishi product is assembled into a user's device, Failure that could have been avoided if functions or structures, judged as necessary in the legal safety measures the user's device is subject to or as necessary by industry standards, had been provided.
4. Failure that could have been avoided if consumable parts (battery, backlight, fuse, etc.) designated in the instruction manual had been correctly serviced or replaced.
5. Failure caused by external irresistible forces such as fires or abnormal voltages, and Failure caused by force majeure such as earthquakes, lightning, wind and water damage.
6. Failure caused by reasons unpredictable by scientific technology standards at time of shipment from Mitsubishi.
7. Any other failure found not to be the responsibility of Mitsubishi or that admitted not to be so by the user.
2. Onerous repair term after discontinuation of production
(1) Mitsubishi shall accept onerous product repairs for seven (7) years after production of the product is discontinued.
Discontinuation of production shall be notified with Mitsubishi Technical Bulletins, etc.
(2) Product supply (including repair parts) is not available after production is discontinued.
3. Overseas service
Overseas, repairs shall be accepted by Mitsubishi's local overseas FA Center. Note that the repair conditions at each FA Center may differ.
4. Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation of damages caused by any cause found not to be the responsibility of Mitsubishi, loss in opportunity, lost profits incurred to the user or third person by Failures of Mitsubishi products, special damages and secondary damages whether foreseeable or not , compensation for accidents, and compensation for damages to products other than Mitsubishi products, replacement by the user, maintenance of on-site equipment, start-up test run and other tasks.
5. Changes in product specifications
The specifications given in the catalogs, manuals or technical documents are subject to change without prior notice.
6. Product application
(1) In using the Mitsubishi graphic operation terminal, the usage conditions shall be that the application will not lead to a major accident even if any problem or fault should occur in the graphic operation terminal device, and that backup and fail-safe functions are systematically provided outside of the device for any problem or fault.
(2) The Mitsubishi graphic operation terminal has been designed and manufactured for applications in general industries, etc.
Thus, applications in which the public could be affected such as in nuclear power plants and other power plants operated by respective power companies, and applications in which a special quality assurance system is required, such as for Railway companies or Public service purposes shall be excluded from the graphic operation terminal applications. In addition, applications in which human life or property that could be greatly affected, such as in aircraft, medical applications, incineration and fuel devices, manned transportation, equipment for recreation and amusement, and safety devices, shall also be excluded from the graphic operation terminal range of applications. However, in certain cases, some applications may be possible, providing the user consults their local Mitsubishi representative outlining the special requirements of the project, and providing that all parties concerned agree to the special circumstances, solely at the users discretion.
Microsoft, Windows, Windows NT, Windows Vista are registered trademarks of Microsoft Corporation in the United States and other countries.
Adobe and Adobe Reader are registered trademarks of Adobe Systems Incorporated.
Pentium and Celeron are a registered trademarks of Intel Corporation in the United States and other countries.
Ethernet is a trademark of Xerox Co., Ltd. in the United States.
MODBUS is a trademark of Schneider Electric SA.
Other company and product names herein may be either trademarks or registered trademarks of their respective owners.
பதிவிறக்கு
விளம்பரம்