Below you will find brief information for AOS061G, AOS101G, AOS201G, AOS102G, AOS202G. This service manual provides information about parameters that can be read and modified via the user interface and service utilities. It covers advanced programming, calibration procedures, error codes, and troubleshooting steps for AOS ovens.
Advertisement
Advertisement
AOS OVENS - Service Manual (595889300 - ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual - CONTENTS: This document contains the information about parameters that can be read and/or modified by means of user interface, service utilities, ... PROJECT REF: AOS ovens AUTHORS: A.Canova CONTRIBUTION BY: D.Vadori F. Fingolo DOCUMENT HISTORY: Rel. Date: File: Author: Note: Valid for firmware 2.30 Valid for any firmware (references only to parameter names) New features from firmware 2.50 and updating of paragraphs, error list Gas ovens; AOS instead of ECS; corrected calibration procedures; firmware 2.6 (reduced the number of parameter so that some of the parameters in the manual are related to old firmware releases) Corrected aerator mistake on 20 1/1 gas boiler. New features from firmware 2.7, 2/1 gas ovens, added appendix B-C-D New calibrations for AOS061G and AOS101G, updated appendix C-D, added appendix E-F-G Updated appendix D, calibration of AOS061G and added appendix H-I Updated calibrations for AOS101G, AOS201G, AOS102G, AOS202G; firmware 2.80 001 11/12/2002 ECS service manual (ENG).001 A. Canova 002 15/01/2003 ECS service manual (ENG).002 A. Canova 003 21/03/2003 ECS service manual (ENG).003 A. Canova 004 05/12/2003 AOS service manual (ENG).004 A. Canova 004a 23/01/2004 AOS service manual (ENG).004a A. Canova 005 06/04/2004 AOS service manual (ENG).005 A. Canova 006 05/07/2004 AOS service manual (ENG).006 A. Canova 007 18/02/2005 AOS service manual (ENG).007 A. Canova 008 13/06/2005 AOS service manual (ENG).008 A. Canova File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.1/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) INDEX 1. PROGRAMMING THE DEFAULT PARAMETERS .................................................................4 2. ADVANCED PROGRAMMING ................................................................................................5 3. BY-PASS CALIBRATION (ONLY FOR LEV. B OVENS)........................................................6 4. LAMBDA PROBE CALIBRATION (ONLY FOR LEV. A OVENS) ..........................................7 5. OFFSET CALIBRATION (ONLY FOR LEV. A OVENS)..........................................................8 6. ERROR CODES .......................................................................................................................8 6.1. ERRORS ..................................................................................................................................8 6.2. WARNINGS...............................................................................................................................8 7. FIRMWARE VERSION.............................................................................................................9 8. WORKING TEMPERATURES .................................................................................................9 9. SERVICE UTILITIES ................................................................................................................9 9.1. UTILITIES THAT CAN BE ACTIVATED WITH OVEN SWITCHED ON....................................................9 9.2. UTILITIES THAT CAN BE ACTIVATED IN PARAMETER PROGRAMMING ..........................................10 10. SELECTION OF THE LANGUAGE FOR THE RECIPE MENU (LEV. A)..............................11 11. CLEANING CYCLE (LEV. A OVENS) ...................................................................................11 12. CYCLES, UTILITIES, IMPORTANT PARAMETERS.............................................................12 13. GAS SYSTEM ........................................................................................................................13 13.1. GAS VALVE .........................................................................................................................14 13.2. OFFSET PRESSURE CALIBRATION ........................................................................................16 13.3. USE OF MANOMETER (FOR OFFSET PRESSURE MEASURE).....................................................16 14. CHANGE OF THE MICROPROCESSOR BOARD................................................................18 APPENDIX A – WATER BOILING POINT ......................................................................................19 APPENDIX B – CONTACTORS DIAGRAM ...................................................................................20 APPENDIX C – CONNECTIONS ON MAIN BOARD......................................................................21 File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.2/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) APPENDIX D – TROUBLESHOOTING ..........................................................................................24 APPENDIX E – LAMBDA PROBE ..................................................................................................29 APPENDIX F – PARAMETER DESCRIPTIONS.............................................................................30 APPENDIX G – GAS CALIBRATIONS ...........................................................................................32 APPENDIX H – WATER TREATMENT...........................................................................................38 APPENDIX I – CONNECTION TO HACCP SYSTEM .....................................................................40 File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.3/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service 1. Programming the default parameters Fig. 2 Fig. 1 Fig. 3 Switch on the oven (fig. 1). Just after the switching on, a lamp test will take place. After the lamp test 4 lines will appear on the cavity temperature display (fig. 2). At this point, while the 4 lines are showed on the display, press the external service buttons (fig.3) till you hear a beep. 1 1 1 Fig. 4 Fig. 5 1 Fig. 6 At this point press the right buttons till you hear a beep (fig. 4). Press then the left service buttons till the beep (fig. 5). At this point release the left buttons keeping pressed the middle one (fig. 6) till you hear 2 beeps. Release the middle button and on the temperature display you will see “PdEF”: the oven will switch off and on automatically. File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.4/40 2 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service 2. Advanced programming Fig. 7 Fig. 8 Fig. 9 The procedure to enter in advanced programming is similar to the procedure for programming the defaults parameters. Switch on the oven (fig. 7). Just after the switching on, a lamp test will take place. After the lamp test 4 lines will appear on the cavity temperature display (fig. 8). At this point, while the 4 lines are showed on the display, press the external service buttons (fig.9) till you hear a beep. 1 1 Fig. 10 1 Fig. 11 At this point press the right buttons till you hear a beep (fig. 10). Press then the left service buttons till the beep (fig. 11). Release the button and on the temperature display you will see “P 1” while on the little display the name of the parameter will appear (fig. 12). With the external service buttons it is possible to scroll the list of the parameters. File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.5/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) Pressing the middle button it is possible to see the value of the parameter (fig. 13) and pressing at this point the external buttons it is possible to modify the value. Press again the middle button returning to the displaying of the number of the parameter to store the new value. Switch off the oven to exit from programming. Fig. 12 Fig. 13 3. By-pass calibration (only for lev. B ovens) In order to calibrate the by-pass probe on lev. B oven, follow these steps: 1) Switch on the oven 2) Enter in parameter programming and set parameter cort to 0 3) Exit from programming and switch on again the oven 4) Wait for the end of the pre-heating cycle 5) Select a steam cycle (100 °C) 6) Select continuous time (indication “cont” on time display) 7) Press and hold down the left service buttons and at the same time press the START button (fig. 14); the oven will give a long beep 8) Release the service buttons and wait for the stabilization of the temperature reading by the by-pass probe 9) When the temperature has stabilized, press the three service button together in order to memorize the value (fig. 15); the oven will confirm the storing with a long beep File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.6/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) 10) Allow the oven to work for several minutes in steam mode checking the oven cavity temperature, which should stabilize at the water boiling point. If this reading is greater or less than the correct water boiling point 1 , a corrective value can be stored in the parameter OCA1. 11) Set parameter cort to 1. 12) Set the altitude above sea level of the site on parameter SEAL Fig. 15 Fig. 14 4. Lambda probe calibration (only for lev. A ovens) The calibration of the lambda probe is necessary (from firmware 2.6) for the right working of the oven in case of cycle with set point under 100 °C. With this procedure we have to find the point of 0% of humidity. The procedure is done in a way similar to the by-pass calibration. These are the steps: 1) Set an hot air cycle, 150 °C, time over 15 minutes, open flap; 2) Start the cycle pressing together the left and middle service buttons and the START button. The oven will give a long beep; 3) Wait around 10-15 minutes to dry completely the cavity; 4) Close the flap and wait around 20 seconds to stabilize the humidity inside the cavity; 5) To store the value press together the 3 service buttons. The oven will confirm with a long beep. 6) Stop the cycle with the START button. This calibration is very important and has to be done with care. If the dry point (0% of humidity) is not correctly stored, the reading of the relative humidity could be overestimated or underestimated. 1 See Appendix A File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.7/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) 5. Offset calibration (only for lev. A ovens) In order to adjust the offset of the cavity probe, enter in parameter programming and set parameter cort to 0. Then run a steam cycle for several minutes and check the cavity temperature, which should stabilize at the water boiling point. If the stabilized cavity temperature is less or greater than the correct water boiling point 2 , a corrective value can be stored in parameter OCA1. After this, set parameter cort to 1and set parameter SEAL (altitude above sea level). 6. Error codes Errors can be divided into 2 categories: errors (they stop the appliance) and warnings (they do not stop the appliance) 6.1. Errors EE2P: Communication error with the EEPROM E---: If the controller detects one or more parameters which have values not permitting the minimum operational requirements, an error code will appear on the display, i.e. “E---” followed by the parameter number. Enter the programming mode and set the correct value according to the parameter list. EtUC: Cavity over temperature; cavity temperature exceeded value stored in parameter cot. EtUB: Boiler over temperature; boiler temperature exceeded value stored in parameter bot. EFUN: Activation of the thermal protection of the motor. On the little temperature display it will appear “UP” or “DOWN” according it is the thermal protection of the upper motor (and the motor of 6-10 grid ovens) or lower motor on 20-grid oven. The thermal protection has an automatic reset but in order to continue with the cooking process, parameter ALFn has to be reset to 0. Etc: Tripping out of cavity limiter Etb: Tripping out of boiler limiter ESCH or ETBR: Over temperature on the electronic board; check the cooling fan and the ventilation openings on the bottom of the control panel. Ept1: cavity probe in open circuit (only the steam cycle – 100 °C can be selected) Ept2: boiler probe in open circuit (only hot air cycle can be selected) Ept3: meat probe in open circuit (only time cooking can be selected) Ept4: by-pass probe in open circuit (only hot air, regeneration or low temperature steam cycle can be selected) Ept8: NTC probe in short or open circuit ECAD: A/D converters not working E PM: Communication error with PWM system E SL: Water level probe error. If the boiler heating elements or burners are on for a tiem over that one defined in parameter tbon without a water charging phase, this error message is activated. To reset it, parameter ALFn has to be reset to 0. burn CAUP: Reset of cavity burner (gas oven) (the upper one in the 20 grid ovens) burn CAdo: Reset of lower cavity burner (gas oven) in 20 1/1 and 2/1 ovens burn boUP: Reset of boiler burner (gas oven) (the upper one in 20 2/1 ovens) burn bodo: Reset of lower boiler burner (gas oven) 6.2. Warnings EH2O: Before the starting of the cleaning system and during its working, there are some check points of the water pressure. If the water pressure is too low this warning message appear on the display. Check the water pressure (1.5÷2.5 bar), check the correct working of the water pressure switch, check if there are obstructions on the cleaning water inlet pipe (its inner diameter must be 20 mm). From firmware release 2.50, EH2O is a warning message and no more an error causing the stopping of the cleaning cycle. EFLP: Cavity ventilation flap failure; check the motoreducer or the micro switch that detects the close position of the flap. If the motoreducer does not close the flap within the time set in parameter FLto, EFLP error appears. ECLO: Clock error, it appears if the clock was never adjusted EPrG: Error in reading the phases of a multiphase recipe EIND: Error in reading the index of the recipes 2 See Appendix A File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.8/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service EDES: Error in reading the description of a recipe ERAM: Communication error with the RAM nFIP: Communication error of recipe display DOOR: Open door (from firmware 2.6 only the led on the control panel switches on) FILL: Safety level probe of the boiler out of water PrEH: Preheating phase of the boiler OPEN: boiler drain activated COOL: Cavity cooling phase 7. Firmware version In order to check the version of the firmware, switch on the oven and wait for the lamp test and the end of the start-up phase (4 lines on the temperature display). When on the temperature display, the actual cavity temperature appears, pressing the three service buttons together on the display temperature the firmware version will appear. Pressing again these buttons, the board temperature will be displayed. 8. Working temperatures While the oven is working, it is possible to see the temperature of the several probes pressing the service buttons. See the following figures: Fig. 16 Boiler temperature Fig. 18 Meat probe temperature Fig. 17 Bypass temperature Fig. 19 PCB temperature 9. Service utilities From firmware release 2.50, some useful utilities are present for troubleshooting and diagnostic of the oven. These additional features can be divided in 2 set: utilities that can be activated with the oven switched on, utilities that can be activated with the oven in parameter programming 9.1. Utilities that can be activated with oven switched on With the oven switched on and not in a cooking phase, pressing simultaneously the following buttons it is possible to activate the detergent, rinser pumps and water valve of the cleaning system: • Steam cycle, combi cycle, temperature buttons (fig. 20): activation of detergent pump • Steam cycle, combi cycle, time buttons (fig. 21): activation of rinser pump • Steam cycle, combi cycle, utility buttons (fig. 22): activation of water valve of the cleaning system These routines are achievable only on lev. A ovens, i.e. with the parameter dCLn set to 0, closed door and cavity temperature less than 80 °C. File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.9/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service Fig. 20 9.2. • • • AOS OVENS - Service Manual (595889300 – ENG) Fig. 21 Fig. 22 Utilities that can be activated in parameter programming Pressing the steam cycle and hot air cycle buttons, all the output relays are sequentially activated and on the time display it will be displayed the activated relay with the message do1, do2, ... (dox=RLx on the EWD) From firmware release 2.7 this utility is changed as follows: o The steam cycle button acts as main switch: if it is released, the test stops. o Each time the hot air cycle button is pressed, the next relay is activated and remains activated till the next pressure of the hot air cycle button. o If the hot air cycle button is kept pressed, the relays are sequentially activated. Pressing the time buttons, the time will be displayed Pressing the utility button, on the time display a 4-characters message will be displayed while on the little display will be shown a number with the following meanings Big display ntc Prb1 Prb2 Prb3 Prb4 File: AOS service manual (ENG).008 Meaning of the number on the little display PCB temperature First meat probe temperature (lev. A) Second meat probe temperature (lev. A) Third meat probe temperature (lev. A) Fourth meat probe temperature (lev. A) ©Copyright 2002 by Electrolux Professional P.10/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service Big display Prb5 Prb6 CEL1 CEL2 boL1 boL2 byP Prb HuM Meaning of the number on the little display Fifth meat probe temperature (lev. A) Sixth meat probe temperature (lev. A) First cavity temperature Second cavity temperature First boiler probe Second boiler probe Bypass probe Single-point meat probe (lev. B) KS contactor is activated for 15 s and the lambda probe is fed and after a while the cavity humidity will be displayed If one of the probes is detecting the same temperature of the ntc probe (PCB temperature), the meanings are the following: 1) Probe in short circuit 2) Probe not connected (for example Prb on a lev. A oven) 3) Probe at the same temperature of the ntc probe • • If the led “open door” is switched on in parameter programming mode, it means that the safety level probe of the boiler is detecting water If the led “scale alarm” is switched on in parameter programming mode, it means that the working level probe of the boiler is detecting water 10. Selection of the language for the recipe menu (lev. A) Starting from firmware release 2.30 on lev. A ovens it is possible to select a language for the menu of the recipes. To select the language, set parameter LanG to the correct value for the desired language (see the relevant parameter list). 11. Cleaning cycle (lev. A ovens) Each cleaning cycle can be divided into the repeating of 3 fundamental phases 3 : Phase A - Washing phase controlled through the parameters CLt1 (time of detergent injection) and CLt2 (time of detergent + water injection) Phase B (like Phase A but with the final sub phase with 20 seconds of water) - Washing phase controlled through the parameters CLt1 (time of detergent injection) and CLt2 (time of detergent + water injection) Phase C - Rinsing and drying phase controlled through the parameters CLt3 (time of rinse aid injection) and CLt4 (time of water injection) The cleaning cycles are composed according the following table: Cycle SOFT CYCLE MEDIUM CYCLE STRONG CYCLE EXTRA–STRONG CYCLE Name of the program CLEAN 1/SOFT CLEAN 2/MEDIUM CLEAN 3/STRONG CLEAN 4/X-STRONG Composition of the phases A+C 2A+C 2A+2B+C 2A+4B+C At the end of a cleaning cycle (at the end of the acoustic signal) the oven enter a stand-by state (from firmware 2.40), i.e. the boiler heating elements are not fed, the user interface shows only the time and the ON-OFF button led is the only lit up led. The exit from this stand-by state takes place with an action from the user: pressing of a button of the user interface or opening the oven door. 3 At the beginning of each phase the cavity is brought at a certain temperature with a COOLING phase without water or with an hot air cycle File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.11/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) NB: To check the correct water installation, make sure the rotating wash arm does not turn below 100 rpm (120 rpm max.) 12. Cycles, utilities, important parameters Hot air cycle: Only the cavity heating elements/burners are working. The maximum temperature is 300 °C; if the set point is over 250 °C, the maximum working time that can be set is given by parameter dutM. If on a lev. A oven a humidity value is set, the lambda probe will control only the cavity flap. Steam cycle: The maximum set point temperature is 100 °C (130 °C from firmware 2.6). Boiler heating elements/burners are controlled with the lambda probe (lev. A ovens) or with the by-pass probe (lev. B ovens) for a set point of 100 °C; for set point lower than 100 °C, the boiler is controlled with the cavity probe. Combi cycle: Boiler and cavity heating elements/burners are working. Cavity heating elements/burners are controlled with the cavity probe; boiler heating elements/burners are controlled by the lambda probe (lev. A ovens) or by the by-pass probe (lev. B ovens). The maximum set point is 250 °C. From firmware 2.6, for a set point lower than 100 °C, to obtain the required steam the humidifier is used (not the boiler). Regeneration cycle: In this cycle boiler and cavity heating elements/burners work alternatively during the first rising (parameter rIGb – it defines the boiler working time – e parameter rIGc – it defines the cavity working time) till the set point is reached. After the set point is reached, boiler and cavity works in parallel to maintain temperature and humidity. DELTA-COOKING cycle: This cooking cycle is used with the meat probe and hot air, steam or combi cycle. For this cycle it is set a Delta temperature (let’s call it D) and not a cavity set-point. The cavity will be thermostatically controlled to have in any moment a cavity temperature that is D °C over the meat probe temperature. COOL: The cavity-cooling mode takes place with the fan running and water injection from the temperature of 180 °C (parameter trMA) to the temperature of 40 °C (parameter trMn). Passing from a cooking cycle to a steam cycle, an automatic cooling phase will take place if the cavity temperature is over 3 °C (parameter dSAc) from the set point of the steam cycle. Boiler automatic drain: The automatic boiler drain takes place each 2 hours of working of the boiler heating elements/burners (parameter dbon) and if the water temperature is lower than 50 °C (parameter tcdb). Then the boiler is automatically filled. Board cooling: The cooling fan is activated starting from the temperature defined in parameter Sbc. Boiler preheating: After the filling of the boiler, the water is heated up to 85 °C (parameter SPHb) and maintained at this temperature if the boiler is not used. Hour counters: The hour counter parameters are the following: hAir: hot air mode hour counter hStM: steam mode hour counter hcMb: combi mode hour counter Parameter PPM: Setting this parameter to 1, the Energy Optimiser function is enabled (with Sicotronic system) in the foreseen electric ovens. The 2 high voltage digital inputs named IND4 (X10-11/5) and IND5 (X10-11/6) and the 2 output relays RL5 and RL24 are used. RL5 is closed each time the oven has to use the heating elements at half or full power while RL24 is closed when the heating elements have to be used at full power (independently from Sicotronic system). IND4 and IND5 are the high voltage inputs of the commands from Sicotronic system: if on IND4 and IND5 are present 230V the oven is working normally; if only one is at 230V the oven is forced from Sicotronic system to work at half power (with no visualization on the display); if both IND4 and IND5 are at 0V, the oven is forced to cut all the heating elements Parameter dEMO: If enabled (set to 1), this parameter makes the oven working in demo function i.e. the user interface is fully working but the oven does not make any real function (no load is activated). Parameter tbon: Timeout for E SL error; if it is set to 0 the control is disabled (from firmware 2.80). Parameter AbSP: Setting this parameter to 1, the selected cooking cycle starts closing the door without pressing the START/STOP button (from firmware 2.80). Parameter dSPS: Setting this parameter to 1 the pre-heating of the boiler is disabled when the oven is not in cooking mode, so the pre-heating will start at the beginning of a combi or steam mode or of a recipe that provided the use of those modes in one of its steps (from firmware 2.80). File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.12/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) 13. Gas system The gas system is made with low emission burners. The main components are: SIT gas valve type SIGMA 848 DC burner fan that is intaking air through a calibrated mixer where the air–gas mixture is created; then the fun conveys the mixture to the burner A cavity and a boiler heat exchanger made with a corrugated tube for increasing the efficiency An ignition rod and a detection rod An ignition device. Starting with a cooking cycle, the POW board of the oven activates the ignition device which activates the burner fan whose speed is controlled with a PWM signal. The POW board activates the ignition device. Form pin 8 of the ignition device a high voltage output is carried to the digital input section of the POW board (X10/5÷8) and to the switching feeder for the burner fans. With an high voltage input on X10/5÷8, the POW board generates on X9/2÷5 a PWM signal to control the speed of the burner fans, i.e. controlling the quantity of sucked gas and air. The PWM signal changes according to the status of the burner, i.e.: Start of the burner: controlled with parameters StcA (start of cavity burners) and Stbo (start of boiler burners). Full power of the burner: controlled with parameters FucA (full power of cavity burners) and Fubo (full power of boiler burners) Half power of the burner: controlled with parameters hAcA (half power of cavity burners) and hAbo (half power of boiler burners) The quantity of sucked gas is controlled with those parameters (which are determining the speed of the burner fans), with the injector/diaphragm inserted at the outlet of the gas valve and with the calibration of the offset value on the gas valve. The quantity of sucked air is controlled with the above parameters and with the calibrated aerator on the mixer. The ignition sequence is then the following: File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.13/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) • • • • The POW boards activates the ignition device After 1.5 s, the ignition device activates the fans that start at the speed determined with parameters Stxx The spark starts for 4 s and after these 4 s there are 2 s for flame detection If the flame is detected, the start speed is maintained for around 6 s and after this time the fans are carried to their working speed (half or full power) • If the flame is not detected, the fan keep on running for an interpurge phase of 15 s; after this phase there is a stop of the fan for 1 s and the ignition sequence is repeated. If the flame is still not detected there will be again 15 s of interpurge phase and then the last ignition attempts before the reset signal. In case of loosening of the flame signal during working, only one re-ignition attempts takes place. In case of conversion to different type of gas, besides the injector/diaphragm also the parameters, which control the PWM signal, have to be changed according to appendix G and the offset pressure has to be set. NB: On 10 1/1 and 20 1/1 ovens, changing from natural gas to LPG or G30 a flow reducer flange (fig. 24 enclosed in the oven) with hole of diameter 21 mm must be put between the cavity burner fan and the cavity burner; on 10 2/1 and 20 2/1 ovens, changing from natural gas to LPG or G30 a flow reducer flange (fig. 25 enclosed in the oven) with hole of diameter 25 mm must be put between the cavity burner fan and the cavity burner 13.1. Gas valve File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.14/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service Injector Remove this threaded cap to get access to the offset adjustment screw Offset pressure test point Inlet pressure test point File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.15/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service - + Offset adjustment screw Offset pressure test point 21 Fig. 23 - Injector 13.2. Fig 24 - LPG flange 1/1 25 Fig. 25 - LPG flange 2/1 Offset pressure calibration For the adjustment of the offset pressure, connect a manometer with a resolution of 1 Pa (100 Pa=1 mbar) to the offset pressure test point after loosening the sealing screw. To adjust the cavity gas valve offset, set an hot air cycle, half power; to adjust the boiler gas valve offset select a steam cycle, half power. Wait around 3 minutes for the stabilization of the pressure before adjusting it turning slowly the screw indicated in the picture above. 13.3. Use of manometer (for offset pressure measure) File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.16/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) Fig. 26 - Manoometer 0S0388 Using the pressure inlet signed with “+” and with negative reading on the display as in the fig. 27-28, this means we are measuring – 0.16 hPa = – 16 Pa: Fig. 27 Fig. 28 Using the pressure inlet signed with “+” and with positive reading on the display as in the fig. 29-30, this means we are measuring + 0.16 hPa = + 16 Pa: Fig. 29 File: AOS service manual (ENG).008 Fig. 30 ©Copyright 2002 by Electrolux Professional P.17/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) Using the pressure inlet signed with “–” and with negative reading on the display as in the fig.31-32, this means we are measuring + 0.16 hPa = + 16 Pa: Fig. 31 Fig. 32 Using the pressure inlet signed with “–” and with positive reading on the display as in the fig. 33-34, this means we are measuring – 0.16 hPa = – 16 Pa: Fig. 33 Fig. 34 14. Change of the microprocessor board In case of changing of the microprocessor board, the following operations/calibrations have to be done: 1) Default parameter programming 2) Change parameters according parameter list 3) Lambda probe calibration for lev. A ovens (from firmware 2.6) 4) By-pass calibration (lev. B ovens) and cavity offset (parameter OCA1) or only cavity offset for lev. A ovens. File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.18/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service APPENDIX A – WATER BOILING POINT Height (m) 0 300 500 800 1000 1500 2000 File: AOS service manual (ENG).008 Water boiling point (°C) 100.00 98.90 98.30 97.50 96.80 95.00 93.50 ©Copyright 2002 by Electrolux Professional P.19/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service APPENDIX B – CONTACTORS DIAGRAM Contactors used on AOS061E_, AOS101E_, AOS102E_ 100% 1/2 HOT AIR 100% 1/2 COMBI 100% 1/2 STEAM KS K1 K2 K3 K4 KS K1 K2 K3 K4 KS K1 K2 K3 K4 Contactors used on AOS201E_, AOS202E_ 100% 1/2 HOT AIR 100% 1/2 COMBI KS K1 K2 K3 K4 K5 K6 K7 K8 File: AOS service manual (ENG).008 100% 1/2 STEAM KS K1 K2 K3 K4 K5 K6 K7 K8 ©Copyright 2002 by Electrolux Professional KS K1 K2 K3 K4 K5 K6 K7 K8 P.20/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) APPENDIX C – CONNECTIONS ON MAIN BOARD X20 X21 X22 X23 X18 X19 X15 X16 X17 X14 Put a jumper to make a short in the not used connections. File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.21/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service X1-1 X10/11-1 X25/26-1 X24-1 X28-1 X12/13-1 X9-1 X2/3-1 X4/5-1 X8-1 X6/7-1 File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.22/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service Connector X1 X2/3 X4/5 X6/7 X8 X9 X10/11 X12/13 X14 X15 X16 X17 X18 X19 X20, X21, X22 X23 X25/26 X28 AOS OVENS - Service Manual (595889300 – ENG) Description Main board supply (24 Vac) Power supply to cavity fan motors, cooling fans, cavity flap motor, switching feeder for the lambda probe Power supply to coils of cavity/boiler heating element contactors or cavity/boiler burner gas valves, steam condensing valve, humidifier valve, cavity lamps Power supply to boiler water filling valves, boiler drain valve Power supply to cleaning system Output of PWM signal for burner fans High voltage digital input, i.e. thermal protection of the cavity fan motors and command signal of the burner fans form the ignition devices Low voltage digital input, i.e. cleaning system water pressure switch, cavity limiter, boiler limiter, door micro switch and micro switch of the cavity flap Connection of bypass probe Connection of cavity probe Connection of boiler probe Connection of single point meat probe Connection of second cavity probe Connection of second boiler probe Connections of multi point probe Connection of lambda probe Connections of water level probes RS485 connection File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.23/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service APPENDIX D – TROUBLESHOOTING Oven Problem AOS Humidity bar always of red or blue colour (or switched off) AOS In the recipe menu the cleaning programs are not present AOS The user interface board does not switch on AOS The oven does not switch on and the ON/OFF led is off AOS AOS The oven does not switch on and the ON/OFF led is on The user interface board does switch on but no load is activated File: AOS service manual (ENG).008 Analysis Probable anomaly Checks/causes 1) Check if the lambda probe is fed: 9.5 Vdc from the relevant switching feeder 2) If 9.5 Vdc are not present, check if the switching feeder is supplied with 230 Vac from the main board 3) Check the fuse on the switching feeder 4) Check the connection of the probe on the main board 5) Check the connections on the lambda probe 6) Change the lambda probe 7) If the humidity bar is switched off, check if parameter LAMb is set to 1 Parameter dCln set to 1 Check and set parameter dCln to 0 Main board powered Switching off and switching the oven on again after few minutes, the oven starts again The previous analysis had a negative result Overtemperature the main board not of 1) Check the correct connection of the power supply cables of the user interface board on the main board 2) Check he connection of the flat cable on the main board 1) Check if voltage is present (24 Vac) at the main board input (X1 connector) 2) Check voltage output (24 Vac) on the transformer 3) Check F1 fuse 1) Check the working of the cooling fan 2) Check the openings on the bottom of the control panel are not clogged Defective electronic component on the main board Change main board Fuse F2 burnt Check fuse ©Copyright 2002 by Electrolux Professional P.24/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service Oven AOS AOS elt Problem In the recipe menu only signs like "P: Sxx" o "Sxx" are appearing Heating of the boiler is slow Analysis Probable anomaly Checks/causes EEPROM of the main board is not programmed Change EEPROM or main board Heating burnt element Contactors working AOS elt AOS gas Heating of the cavity is slow The fan of a burner is working always at the maximum speed Heating burnt not element Contactors working not PWM signal present not The fan is not powered (24 Vdc) AOS gas The fan of a burner does not start PWM signal at 0 File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional Check that all the branches of the boiler heating elements are working Check correct working of the contactors (see appendix B) Check that all the branches of the cavity heating elements are working Check correct working of the contactors (see appendix B) 1) The connector of PWM signal (X9) on the main board is not connected 2) PWM signal cable is interrupted 1) Check if the fan is powered: 24 Vdc from the relevant switching feeder. 2) Check fuse on the relevant switching feeder if 24 Vdc are not present 1) Exchange the PWM cable between cavity and boiler fan to check if the fan starts 2) Check if high voltage digital signal is present on X10/11-5÷8 3) Close the gas tap, disconnect connector X9 and try to start the burner: the fan has to run at the maximum speed. If this is not happening, change fan. If the fan starts, change main board. P.25/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service Oven Problem AOS gas The cavity burner is whistling or grumbling Gas-air mixture not correct AOS gas The boiler burner is whistling or grumbling Gas-air mixture not correct AOS gas The main board is switching off/on by itself Coupling of voltage and voltage circuits File: AOS service manual (ENG).008 Analysis Probable anomaly ©Copyright 2002 by Electrolux Professional high low Checks/causes 1) Check PWM parameters for the cavity burner 2) Check offset pressure 3) Check injector 4) Check aerator 5) With LPG on 10-20 grid ovens (1/1 or 2/1), check the presence of the flange after the burner fan 6) Set to 0 the parameter Sbc in order to have the cooling fan always working supplying with air the burners 1) Check PWM parameters for the boiler burner 2) Check offset pressure 3) Check injector 4) Check aerator 5) Set to 0 the parameter Sbc in order to have the cooling fan always working supplying with air the burners 6) Check integrity of the gasket of the boiler burner 1) Check the separation between high voltage and low voltage cables 2) Check integrity of ignition cables: they must not be cracked discharging towards inner components of the oven 3) Reinforce the insulation of the ignition cables with a silicon pipe P.26/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service Oven Problem Analysis Burner fan is working, "burn xxx" error after the 3 ignition attempts Burner fan is working, no ignition attempts AOS gas Probable anomaly Gas tap is closed Not correct injector Not correct aerator Not correct values in the PWM parameters Too low setting for the offset pressure Gas valve is not opening (the offset pressure during ignition is very high around 1.00 hPa) No continuity on the bridge between terminals 5-6-7 of the ignition device Burner fan not powered (24 Vdc) Burner does not light Burner fan is not working, "burn xxxx" error after the 3 ignition attempts PWM signal at 0 Burner fan is not working, "burn xxxx" error appears with no ignition attempts after reset File: AOS service manual (ENG).008 Lack of 230 Vac signal on X10/11 ©Copyright 2002 by Electrolux Professional Checks/causes Open gas tap Check injector Check aerator Check PWM parameters Check offset calibration 1) Check the ignition device is well fixed and connected to the gas valve 2) Faulty gas valve Restore continuity 1) Check that the relevant switching feeder TR_Fx is powered through fuse F2 2) Check fuse on TR_Fx 3) Check that 24 Vdc are present at the output of TR_Fx (J1-1 e J1-2, J1-3 e J1-4) and at the input on the fan (with connector X9 disconnected and 24 Vdc present at the input on the burner fan, this has to run at the maximum speed see also the following point 1) 4) Check correct connections between TR_Fx and the burner fan 1) Close the gas tap, disconnect connector X9 and try to start the burner: the fan has to run at the maximum speed. If this is not happening, change burner fan. 2) If with X9 disconnected the fan starts, check connections on X9 and if they are correct change main board 1) Ignition device is not giving the 230 Vac signal from terminal 8, change ignition device 2) Check connection from ignition device to TR_Fx and to X10/11 P.27/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service Oven AOS gas Problem The burners switch on only for few seconds and then they switch off Analysis The problem occurs on all the burners (cavity and boiler) The problem occurs only on a cavity burner or on boiler burner Probable anomaly Checks/causes Inversion of PhaseNeutral Check cables on main terminal board Detection problem Change the ignition device with one working device to check if the problem persists Check detection rod and integrity of relevant cable Water level probes covered with scale or other Check water level probes Broken probe cable Water level probe are not detecting water AOS gas Water level system on main board not working Oven is always loading water, water in the cavity overflowing from the boiler Noise circuit File: AOS service manual (ENG).008 on ground Bad ground connection of some devices inside the oven, mainly the switching feeder TR_Fx or TR_HC are not connected to ground ©Copyright 2002 by Electrolux Professional Check continuity of the cable Make a short between X25/26-1 and X25/26-3: the fast filling valve has to close; make a short between X25/26-2 and X25/26-3: the slow filling valve has to close. If this is not happening change main board but before check also next point Check the connections ground P.28/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) APPENDIX E – LAMBDA PROBE In the lev. A AOS ovens the lambda probe is used to measure the humidity. How does it work? The lambda probe permits measurement of oxygen concentration through a solid electrolyte (ceramic element) The ceramic part of the probe is in the form of a tube closed at one end. The inside and outside surfaces of the ceramic sensor have a microporous platinum layer (electrode). The platinum layer, which is in contact with the analyzed gas, is covered with a highly porous protective ceramic layer. The ceramic sensor (ZrO2 – solid electrolyte) is heated from inside by means of a ceramic heater so that the temperature of the sensor ceramic remains above 350 °C. Starting from 300°C, the ZrO2 sensor becomes conductive for the oxygen ions so that if there is a different concentration of oxygen at the two sides of the sensors (one side is in contact with the analyzed gas, the other side is in contact with the external), a voltage is generated. Since the Oxygen/Nitrogen ratio in the air is constant, a measurement of the concentration of oxygen enables the percentage of a third gas (in this case water vapor) to be determined. In fact the addition of a third gas to a sample of air has the effect of reducing in a proportional manner the presence of oxygen and nitrogen so that, as said, determining the relative concentration of oxygen allows the amount of the third introduced gas of the mixture to be determined (see the diagram). 100 90 80 water 70 60 50 40 nitrogen 30 20 10 oxygen 0 0 10 20 30 40 50 60 70 80 90 100 water percentage Connections on the lambda probe: Pin 1: not used Pin 2-3: connections to the main board (connector X23) Pin 4-5: connections to the switching feeder File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.29/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service APPENDIX F – PARAMETER DESCRIPTIONS Name 5060 6Prb AbSP Addr ALFn APPL APPM bAud bot CLPr CLt1 CLt2 CLt3 CLt4 cort cot cu dbon dCLn dEMO dScb dSod dSPS dtoF dton dtSb dutM EMME EnFL Ertc FAHr FrE Fubo FucA GAS hAbo HAbP hAcA Description Frequency Presence of 6-point meat probe (1=yes for lev. A, 0 for lev. B) Flag to enable starting of cooking closing the door (0=disable; 1=enable) RS485 address Activation of cavity motor thermal protection Level of the oven Type of oven RS485 bit rate Max. steam generator overheating (ETUB alarm) Length of cooling with humidifier after a steam phase in an automatic cleaning cycle Length of detergent injection (phase A) Length of detergent+water injection (phase A) Length of rinser+water injection (phase C) Length of water injection (phase C) Flag to enable cavity temperature displaying adjustment Max. cooking chamber overheating (ETUC alarm) Parameter q of SCELOFF=SCEL-(q+m*dT/dt) (FUZZY-LOGIC) Delay for boiler drain Flag to disable automatic cleaning cycles (1=disable) Flag to enable DEMO (0=disable; 1=enable) Temperature range (from set) above which the middle power is activated in combi mode Flag to disable the oven stops when door is open in convection, steam and combi mode: (0=the oven stops) Flag to disable pre-heating of the boiler when the oven is in stand-by mode (0=enable pre-heating; 1=disable) Max. cooking chamber temperature derivative value for heating elements to be switched OFF (FUZZY-LOGIC) Max. cooking chamber temperature derivative value for heating elements to be switched ON (FUZZY-LOGIC) Delay for activation of fast filling during opening of boiler drain valve Maximum length of a phase with cavity temperature over 250 ºC Parameter m of SCELOFF=SCEL-(q+m*dT/dt) (FUZZY-LOGIC) Presence of motorised cavity flap (1=yes) Flag to enable RTC (1=enable) Temperature unit (°F = 1, °C = 0) PWM frequency PWM value at full power of boiler burners PWM value at full power of cavity burners Define if the oven is GAS heated (1) or ELECTRIC heated (0) PWM value at middle power of boiler burners Steam condenser engagement in "hot air" mode PWM value at middle power of cavity burners HAFd Bypass temperature variation for humidification during hot air mode + open flap HAFI By pass isteresys in hot air+open flap mode HAFS hAir Bypass base temperature for humidification during hot air mode + open flap Hot air hour counter File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.30/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service Name hboL HbYP HCCP hcMb hStM HUIM HUon I ISG LAMb LAnG MHUM MISG nMod nPrG OCA1 OCA2 OLbd OPr1 OPr2 OPr3 OPr4 OPr5 OPr6 pdEr PI PPM Sbc SbYP SEAL SInC SPHb SPHF Stbo StbP StcA StoF Ston tbon tcdb thMA tPrm trMA trMn AOS OVENS - Service Manual (595889300 – ENG) Description Boiler hour counter Max humidity value to stop the boiler HACCP Mode Combi hour counter Steam hour counter Pulse length of manual humidifier ON phase of the humidifier with combi cycle beetween 50 and 100 degrees Parameter i of SCELON=SCEL(1+p/400)-i (FUZZY-LOGIC) Define if the oven is an ISG oven (0 means oven with boiler) Presence of lambda probe (1=yes) Language for the menu Flag manual humidifier 0=Off 1=On Max temperature allowed for water injection in ISG Define if the modification of store program is disable Max number of programs OFFSET of first cavity probe OFFSET of second cavity probe Calibration of the lambda probe OFFSET of first probe of 6-point meat probe OFFSET of second probe of 6-point meat probe OFFSET of third probe of 6-point meat probe OFFSET of fourth probe of 6-point meat probe OFFSET of fifth probe of 6-point meat probe OFFSET of sixth probe of 6-point meat probe Sample period to calculate the derivative value (FUZZY-LOGIC) Parameter p of SCELON=SCEL(1+p/400)-i (FUZZY-LOGIC) Flag to enable Peak Power Management (0=disable; 1=enable) Cooling temperature set for board ventilation Bypass temperature with max. cooking cavity steam temperature (calibration) Altitude above sea level Boiler temperature that detect presence of scale Preheating temperature of the boiler Boiler temperature during leavening PWM value at start of boiler burners Steam condenser engagement in "boiler" mode PWM value at start of cavity burners Minimum time for "switch off" of boiler Minimum time for "switch on" of boiler Timeout for E SL alarm, water level probe alarm Max water temperature for boiler drain Define the max. temperature limit for the manual injection of water Print frequency (0=no print) Define the max. temperature for water injection during cooling phase Define the min. temperature for water injection during cooling phase File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.31/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service APPENDIX G – GAS CALIBRATIONS AOS061G CAVITY BURNER GAS Injector Aerator OFFSET Parameters (hPa) StcA hAcA FucA G20 6.50 Yellow - 0.20 35 30 60 G25 7.80 Yellow - 0.20 35 30 60 G30 5.30 Yellow - 0.25 40 28 43 LPG 5.30 Yellow - 0.13 40 28 43 BOILER BURNER GAS Injector Aerator OFFSET Parameters (hPa) Stbo hAbo Fubo G20 6.50 Yellow - 0.20 55 35 78 G25 7.80 Yellow - 0.20 55 35 78 G30 5.30 Yellow - 0.28 55 36 66 LPG 5.30 Yellow - 0.18 55 36 66 File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.32/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS101G CAVITY BURNER GAS Injector Aerator OFFSET (hPa) Parameters StcA hAcA FucA G20 7.00 Red - 0.25 80 26 100 G25 8.00 Red - 0.25 80 26 100 LPG2/30 5.50 Red - 0.07÷ 0.00 23 26 100 LPG1 5.70 Red - 0.15÷ - 0.08 23 26 100 BOILER BURNER GAS Injector Aerator OFFSET (hPa) Parameters Stbo hAbo Fubo G20 7.00 Red - 0.10 50 50 100 G25 8.00 Red - 0.10 40 50 100 G30 5.70 Red - 0.28 33 45 74 LPG 5.70 Red - 0.15 33 45 74 LPG conversion for cavity burner for AOS101G For LPG installations, put the ø 21 flow reducer flange between cavity burner fan and cavity burner. Change the PWM parameters. Then change the injector with the 5.70 one and calibrate the offset in the range - 0.15 ÷ - 0.08 hPa so as to eliminate possible whistles/noises (row LPG1). After you have found the best working condition, cool down and verify ignitions with cold burner. If the previous setting does not eliminate whistles or noise, change the 5.70 injector with the 5.50 one and use the calibrations of LPG2/G30 row: calibrate the offset in the range - 0.07 ÷ 0.00 hPa so as to eliminate possible whistles/noises (row LPG1). After you have found the best working condition, cool down and verify ignitions with cold burner. File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.33/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS201G UPPER CAVITY BURNER GAS Injector Aerator OFFSET (hPa) Parameters StcA hAcA FucA G20 7.00 Red - 0.25 80 26 100 G25 8.00 Red - 0.25 80 26 100 LPG2/G30 5.50 Red - 0.07÷ 0.00 23 26 100 LPG1 5.70 Red - 0.15÷ - 0.08 23 26 100 LOWER CAVITY BURNER GAS Injector Aerator OFFSET (hPa) Parameters StcA hAcA FucA G20 7.00 Red - 0.25 80 26 100 G25 8.00 Red - 0.25 80 26 100 LPG2/G30 5.50 Red - 0.07÷ 0.00 23 26 100 LPG1 5.70 Red - 0.15÷ - 0.08 23 26 100 BOILER BURNER GAS Injector Aerator OFFSET (hPa) Parameters Stbo hAbo Fubo G20 8.00 Blue 0 42 45 100 G25 8.50 Blue 0 42 45 100 G30 6.15 Blue - 0.15 30 37 72 LPG 6.15 Blue 0 30 37 72 LPG conversion for cavity burner for AOS201G For LPG installations, put the ø 21 flow reducer flange between cavity burner fan and cavity burner. Change the PWM parameters. Then change the injector with the 5.70 one and calibrate the offset in the range - 0.15 ÷ - 0.08 hPa so as to eliminate possible whistles/noises (row LPG1). After you have found the best working condition, cool down and verify ignitions with cold burner. If the previous setting does not eliminate whistles or noise, change the 5.7°0 injector with the 5.50 one and use the calibrations of LPG2/G30 row: calibrate the offset in the range - 0.07 ÷ 0.00 hPa so as to eliminate possible whistles/noises (row LPG1). After you have found the best working condition, cool down and verify ignitions with cold burner. File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.34/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS102G CAVITY BURNER GAS Injector Aerator OFFSET (hPa) Parameters StcA hAcA FucA G20 7.00 Red - 0.17÷ - 0.10 45 43 100 G25 8.50 Red - 0.17÷ - 0.10 45 43 100 G30 5.70 Red - 0.25÷ - 0.18 60 43 100 LPG 5.70 Red - 0.10÷ - 0.02 60 43 100 BOILER BURNER GAS Injector Aerator OFFSET (hPa) Parameters Stbo hAbo Fubo G20 7.00 Red 0 43 50 100 G25 8.50 Red 0 43 50 100 G30 5.70 Red - 0.15 35 45 78 LPG 5.70 Red 0 35 45 78 LPG conversion for cavity burner for AOS102G For LPG installations, put the ø 25 flow reducer flange between cavity burner fan and cavity burner. Change the PWM parameters. Then change the injector with the 5.70 one and calibrate the offset in the range - 0.10 ÷ - 0.02 hPa so as to eliminate possible whistles/noise. After you have found the best working condition, cool down and verify ignitions with cold burner. File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.35/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS202G UPPER CAVITY BURNER GAS Injector Aerator OFFSET (hPa) Parameters StcA hAcA FucA G20 7.00 Red - 0.20 45 43 100 G25 8.00 Red - 0.20 45 43 100 G30 5.70 Red - 0.20 ÷ - 0.15 40 43 95 LPG 5.70 Red - 0.10 ÷ - 0.05 40 43 95 LOWER CAVITY BURNER GAS Injector Aerator OFFSET (hPa) Parameters StcA hAcA FucA G20 7.00 Red - 0.20 45 43 100 G25 8.00 Red - 0.20 45 43 100 G30 5.70 Red - 0.25 ÷ - 0.20 40 43 95 LPG 5.70 Red - 0.15 ÷ - 0.10 40 43 95 UPPER BOILER BURNER GAS Injector Aerator OFFSET (hPa) Parameters Stbo hAbo Fubo G20 7.50 Red - 0.05 ÷ 0.00 40 50 100 G25 8.50 Red - 0.05 ÷ 0.00 40 50 100 LPG2/G30 5.80 Red - 0.07 ÷ - 0.02 40 45 90 LPG1 6.00 Red - 0.07 ÷ - 0.02 40 45 90 LOWER BOILER BURNER GAS Injector Aerator OFFSET (hPa) Parameters Stbo hAbo Fubo G20 7.50 Red - 0.05÷0.00 40 50 100 G25 8.50 Red - 0.05÷0.00 40 50 100 LPG2/G30 5.80 Red - 0.07÷- 0.02 40 45 90 LPG1 6.00 Red - 0.07÷- 0.02 40 45 90 File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.36/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) LPG conversion for cavity burners for AOS202G For LPG installations, put the ø 25 flow reducer flange between cavity burner fan and cavity burner. Change the PWM parameters. Then change the injector with the 5.70 one and calibrate the offset in the range - 0.10 ÷ - 0.05 hPa (upper cavity boiler) and - 0.15 ÷ - 0.10 hPa (lower cavity boiler) so as to eliminate possible whistles/noise. After you have found the best working condition, cool down and verify ignitions with cold burner. LPG conversion for boiler burners for AOS202G Change the PWM parameter. Then change the injector with the 6.00 one and calibrate the offset in the range - 0.07 ÷ - 0.02 hPa (upper and lower boiler burner) so as to eliminate possible whistles/noise (row LPG1). After you have found the best working condition, cool down and verify ignitions with cold burner. If the previous setting does not eliminate whistles or noise, change the 6.00 injector with the 5.80 one and use the calibration of LPG2/G30 row: calibrate the offset in the range - 0.07 ÷ - 0.02 hPa (upper and lower boiler burner) so as to eliminate possible whistles/noise. After you have found the best working condition, cool down and verify ignitions with cold burner. File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.37/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) APPENDIX H – WATER TREATMENT File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.38/40 AOS OVENS - Service Manual (595889300 – ENG) Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service Summary table: Graph Hardness Treatment Not required < 5°F Not required File: AOS service manual (ENG).008 Not required > 5°F Softener Nanofilter < 5°F Nanofilter Nanofilter >5°F Nanofilter ©Copyright 2002 by Electrolux Professional Osmotizer < 5°F Osmotizer Osmotizer > 5°F Osmotizer P.39/40 Electrolux Professional S.p.A. Ovens Platform Customer Support Technical Training & Service AOS OVENS - Service Manual (595889300 – ENG) APPENDIX I – CONNECTION TO HACCP SYSTEM The AOS oven (from firmware 2.7) can be predisposed for the HACCP system through 4 parameters: HCCP: defines the type of HACCP, i.e. 0: no system 1: HACCP Basic (with printer 881457 – 880048 for US market, i.e. 120V/1ph/60 Hz) 2: HACCP Advanced or Integrated bAud: bit rate of RS485 connection Addr: address of the appliance in the HACCP Advanced network tPrn: print frequency in case of HACCP Basic (value in seconds) In case of HACCP Basic, i.e. setting HCCP to 1, to use the printer 881457 (or 880048) and print with the printing frequency given through parameter tPrn, set on the printer the following parameters: PROTOCOL = 8,E,1 BAUD RATE = 9600 PRINT = REVERSE 40 COLUMNS (font 9x24) RS485 INTERFACE NO id In case of HACCP Advanced or Integrated, i.e. setting HCCP to 2, the address of the oven in the AHCCP network has to be set in the parameter Addr. File: AOS service manual (ENG).008 ©Copyright 2002 by Electrolux Professional P.40/40 ">
Download
Advertisement
Key features
Parameter programming
Calibration procedures
Error code troubleshooting
Gas system adjustments
Wiring diagrams
Firmware version check
Frequently asked questions
Switch on the oven, press the external service buttons until you hear a beep, and follow the specific button sequence detailed in the manual.
Switch on the oven, wait for the startup phase, and press the three service buttons together to display the firmware version.
Enter the programming mode and set the correct value according to the parameter list provided in the manual.
Set a hot air cycle, start the cycle while pressing specific service buttons, wait to dry the cavity completely, and store the value by pressing the three service buttons together.