HP (Hewlett-Packard) | 595166-001 | User manual | HP ProLiant DL/ML370 G6 Server User Guide
Add to my manuals
172 Pages
advertisement
HP ProLiant DL/ML370 G6 Server
User Guide
Abstract
This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Part Number: 513482-004
May 2011
Edition: 4
© Copyright 2009, 2011 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation.
Bluetooth is a trademark owned by its proprietor and used by Hewlett-Packard Company under license.
Contents
Contents 3
Contents 4
Contents 5
Contents 6
Component identification
Front panel components
1
2
Item Description
USB connectors (2)
Drive cage blank
3
SAS/SATA drives (8)
4
Front video connector (rack model only)
5
Systems Insight Display
6
Removable media bay
7
DVD-ROM drive
8
Optical drive blank
Component identification 7
Front panel LEDs and buttons
Item Description
1
Power On/Standby button and system power LED
2
Health LED
3
UID LED
Status
Green = Normal (system on)
Amber = System in standby, but power still applied
Off = Power cord not attached or power supply failure
Green = Normal (system on)
Amber = System health is degraded
Red = System health is critical.
Off = Normal (system off)
Blue = Activated
Flashing blue = System is being managed remotely
Off = Deactivated
Component identification 8
Systems Insight Display LEDs
The HP Systems Insight Display LEDs represent the system board layout.
Item Description
1
Power cap
2
AMP Status
Status
To determine Power cap status, see
"Systems Insight Display LED combinations
Green = AMP mode enabled
Amber = Failover
Flashing amber = Invalid configuration
Off = AMP mode disabled
All LEDs flashing = DIMM unseated
3
DIMM LEDs
All other LEDs Amber = Failure
Off = Normal
IMPORTANT: If more than one DIMM slot LED is illuminated, further troubleshooting is required.
Test each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing each DIMM in a bank with a known working DIMM.
Systems Insight Display LED combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing a health event. Combinations of illuminated Systems Insight Display LEDs, the system power LED, and the health LED indicate system status.
Component identification 9
Systems Insight Display
LED and color
Health LED System power
LED
Red Amber
Status
Processor (amber)
Processor (amber)
Fan (amber)
Fan (amber)
Amber
DIMM (amber)
DIMM (amber)
Red
Amber
Overtemperature (amber) Amber
Overtemperature (amber) Red
Amber
Red
Green
Green
Green
Green
Amber
Green
Green
One or more of the following conditions may exist:
•
Processor in socket X has failed.
•
Processor X is not installed in the socket.
•
Processor X is unsupported.
•
ROM detects a failed processor during
POST
Processor in socket X is in a pre-failure condition.
One or more DIMMs have failed.
DIMM in slot X is in a pre-failure condition.
The Health Driver has detected a cautionary temperature level.
The server has detected a hardware critical temperature level.
One fan has failed or has been removed.
Two or more fans have failed or been removed.
Power supply (amber)
Power supply (amber)
Power cap (off)
Power cap (green)
Power cap (flashing amber)
Power cap (green)
Red
Amber
—
—
—
—
Amber
Green
Amber
Flashing green
Amber
Green
•
Only one power supply is installed and that power supply is in standby.
•
Power supply fault
•
System board fault
•
Redundant power supply is installed and only one power supply is functional.
•
AC power cord is not plugged into redundant power supply.
•
Redundant power supply fault
•
Power supply mismatch at POST or power supply mismatch through hot-plug addition.
Standby
Waiting for power
Power cap has been exceeded
Power is available
IMPORTANT: If more than one DIMM slot LED is illuminated, further troubleshooting is required.
Test each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing each DIMM in a bank with a known working DIMM.
Component identification 10
Rear panel components
9
10
11
Item Description
1
Mouse connector
2
Keyboard connector
3
Serial connector
4 iLO 2 connector
5
USB connectors (2)
6
NIC connectors (4)
7
PCI expansion slots
8
Reserved for PCI-X option kit
Video connector
Power supply bay 2
Power supply bay 1 (populated)
Component identification 11
Rear panel LEDs
Item Description
1
UID LED
2 iLO 2 activity LED
3 iLO 2 link LED
4
NIC link LED
5
NIC activity LED
6
Power supply LED
Status
Blue = Activated
Flashing blue = System is being managed remotely.
Off = Deactivated
Green or flashing green = Network activity
Off = No network activity
Green = Linked to network
Off = No network connection
Green = Linked to network
Off = No network connection
Green or flashing green = Network activity
Off = No network activity
Green = System has AC power and is powered up.
Off = System has no AC power, the system is off, or the power supply has failed.
Component identification 12
System board components
Item
14
15
16
17
18
19
20
21
22
7
8
9
5
6
3
4
1
2
10
11
12
13
23
24
25
Description
SD card slot
Power backplane connector
Processor 1 DIMM slots
Power supply connector
SAS connector B
SAS connector A
Front panel connector
Systems Insight Display connector
Front video connector
Front USB connector
Smart Array P410i memory module
Reserved
System battery
TPM connector
SATA connectors (6)
Slot 1 PCIe x8 (4, 2, 1)
Slot 2 PCIe2 x8 (4, 2, 1)
Slot 3 PCIe2 x16 (16, 8, 4, 2, 1)
System maintenance switch
Slot 4 PCIe2 x8 (4, 2, 1)
Slot 5 PCIe2 x8 (4, 2, 1)
Slot 6 PCIe2 x16 (8, 4, 2, 1)
Slot 7 PCIe2 x8 (4, 2, 1)
Slot 8 PCIe2 x16 (16, 8, 4, 2, 1)
Slot 9 PCIe2 x8 (4, 2, 1)
Component identification 13
Item
26
27
28
29
30
31
Description
Slot 10 PCIe2 x8 (8, 4, 2, 1)
Internal USB connector
Processor socket 2
Processor 2 DIMM slots
Power supply connector
Processor socket 1 (populated)
DIMM slots
DIMM slots are numbered sequentially (1 through 9) for each processor. The supported AMP modes use the letter assignments for population guidelines.
System maintenance switch
The system maintenance switch (SW1) is a ten-position switch that is used for system configuration.
Position Description Function
S1 iLO security Off = iLO security is enabled.
On = iLO security is disabled.
Component identification 14
S3
S4
S5
Position
S2
S6
S7
Description Function
Configuration lock
Off = System configuration can be changed.
On = System configuration is locked.
Rack/Tower ID Off = Tower
On = Rack
Reserved
Password protection override
Invalidate configuration
Reserved
Reserved
Off = No function
On = Clears power-on password and administrator password
Off = Normal
On = ROM treats the system configuration as invalid.
Reserved
S8
Reserved Reserved
S9
Reserved Reserved
S10
Reserved Reserved
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all system configuration settings from both CMOS and NVRAM.
CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to properly configure the server or data loss could occur.
NMI functionality
An NMI crash dump enables administrators to create crash dump files when a system is hung and not responding to traditional debug mechanisms.
Crash dump log analysis is an essential part of diagnosing reliability problems, such as hangs in operating systems, device drivers, and applications. Many crashes freeze a system, and the only available action for administrators is to cycle the system power. Resetting the system erases any information that could support problem analysis, but the NMI feature preserves that information by performing a memory dump before a hard reset.
To force the OS to invoke the NMI handler and generate a crash dump log, the administrator can do any of the following:
•
Short the NMI jumper pins
•
Press the NMI switch
•
Use the iLO Virtual NMI feature
For additional information, see the whitepaper on the HP website
( http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf
).
Component identification 15
SAS and SATA device numbers
With optional hard drive cages installed, the server supports up to 24 SFF hard drives or up to 14 LFF hard drives. The server does not support mixing SFF and LFF hard drives.
HP recommends populating hard drive bays starting with the lowest SAS or SATA device number.
•
SFF hard drives
•
LFF hard drives
Component identification 16
SAS and SATA hard drive LEDs
Item Description
1
Fault/UID LED
2
Online/activity LED
Status
Amber = Drive failure
Flashing amber = Fault-process activity
Blue = Unit identification is active
Off = No fault-process activity
Green = Drive activity
Flashing green = High activity on the drive or drive is being configured as part of an array
Off = No drive activity
SAS and SATA hard drive LED combinations
Online/activity
LED (green)
Fault/UID LED
(amber/blue)
Interpretation
On, off, or flashing
On, off, or flashing
On
On
Flashing regularly
(1 Hz)
Alternating amber and blue
The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application.
Steadily blue
Amber, flashing regularly (1 Hz)
Off
Amber, flashing regularly (1 Hz)
The drive is operating normally, and it has been selected by a management application.
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
The drive is online, but it is not active currently.
Do not remove the drive. Removing a drive may terminate the current operation and cause data loss.
The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete.
Component identification 17
Off
Fans
Off
Online/activity
LED (green)
Flashing regularly
(1 Hz)
Fault/UID LED
(amber/blue)
Off
Flashing irregularly
Flashing irregularly
Off
Amber, flashing regularly (1 Hz)
Off
Steadily amber
Amber, flashing regularly (1 Hz)
Off
Interpretation
Do not remove the drive. Removing a drive may terminate the current operation and cause data loss.
The drive is rebuilding, or it is part of an array that is undergoing capacity expansion or stripe migration.
The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible.
The drive is active, and it is operating normally.
A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible.
A predictive failure alert has been received for this drive. Replace the drive as soon as possible.
The drive is offline, a spare, or not configured as part of an array.
Item
3
4
1
2
5
Description
Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
Configuration
Redundant
Primary
Redundant
Primary
Primary
Component identification 18
Battery pack LEDs
Item ID Color
1
Green
2
3
Green
Amber
Description
System Power LED. This LED glows steadily when the system is powered up and 12 V system power is available. This power supply is used to maintain the battery charge and provide supplementary power to the cache microcontroller.
Auxiliary Power LED. This LED glows steadily when 3.3V auxiliary voltage is detected. The auxiliary voltage is used to preserve BBWC data and is available any time that the system power cords are connected to a power supply.
Battery Health LED. To interpret the illumination patterns of this LED, see the following table.
4
Green BBWC Status LED. To interpret the illumination patterns of this LED, see the following table.
LED3 pattern LED4 pattern Interpretation
—
—
One blink every two seconds
Double blink, then pause
The system is powered down, and the cache contains data that has not yet been written to the drives. Restore system power as soon as possible to prevent data loss.
Data preservation time is extended any time that 3.3 V auxiliary power is available, as indicated by LED 2. In the absence of auxiliary power, battery power alone preserves the data. A fully-charged battery can normally preserve data for at least two days.
The battery lifetime also depends on the cache module size. For further information, refer to the controller QuickSpecs on the HP website
( http://www.hp.com
).
The cache microcontroller is waiting for the host controller to communicate.
Component identification 19
LED3 pattern LED4 pattern Interpretation
—
—
—
One blink per second
Steady glow
One blink per second
One blink per second
Steady glow
Off
One blink per second
—
—
The battery pack is below the minimum charge level and is being charged. Features that require a battery (such as write cache, capacity expansion, stripe size migration, and RAID migration) are temporarily unavailable until charging is complete. The recharge process takes between 15 minutes and two hours, depending on the initial capacity of the battery.
The battery pack is fully charged, and posted write data is stored in the cache.
The battery pack is fully charged, and there is no posted write data in the cache.
An alternating green and amber blink pattern indicates that the cache microcontroller is executing from within its boot loader and receiving new flash code from the host controller.
There is a short circuit across the battery terminals or within the battery pack. BBWC features are disabled until the battery pack is replaced.
The life expectancy of a battery pack is typically more than three years.
There is an open circuit across the battery terminals or within the battery pack. BBWC features are disabled until the battery pack is replaced. The life expectancy of a battery pack is typically more than three years.
FBWC module LEDs
The FBWC module has two single-color LEDs (green and amber). The LEDs are duplicated on the reverse side of the cache module to facilitate status viewing.
Green LED
Off
Flashing (1 Hz)
Flashing (1 Hz)
On
Amber LED
On
On
Off
Off
Interpretation
A backup is in progress.
A restore is in progress.
The capacitor pack is charging.
The capacitor pack has completed charging.
Component identification 20
Green LED
Flashing (2 Hz)
Alternating with amber LED
On
Off
Amber LED
Flashing (2 Hz)
Alternating with green LED
On
Off
Interpretation
One of the following conditions exists:
•
The charging process has timed out.
•
The capacitor pack is not connected.
The flash code image failed to load.
The flash code is corrupt.
Power supply backplane connectors
Item
BP1
Description
Drive bay 1 power cable
BP2
Drive bay 2 power cable
BP3
Drive bay 3 power cable
P1
Power supply 1 cable
P2
Power supply 2 cable
P6
SATA power cable
P7
SATA power cable
P8
SATA power cable
P9
Video adapter power cable
P10
Data cable
P12
Video adapter power cable
Drive cage jumper configuration settings
Drive cage Installation Pin setting
1
Standard No jumper
2
Optional 1-2*
3
Optional 2-3
*Optional drive cages ship with the jumper set across pins 1 and 2.
Component identification 21
Operations
Power up the server
To power up the server, press the Power On/Standby button.
Power down the server
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.
IMPORTANT: If installing a hot-plug device, it is not necessary to power down the server.
1.
2.
Back up the server data.
Shut down the operating system as directed by the operating system documentation.
NOTE: If the operating system automatically places the server in Standby mode, omit the next step.
3.
Press the Power On/Standby button to place the server in Standby mode. When the server activates
Standby power mode, the system power LED changes to amber.
IMPORTANT: Pressing the UID button illuminates the blue UID LEDs on the front and rear panels.
In a rack environment, this feature facilitates locating a server when moving between the front and rear of the rack.
4.
Disconnect the power cords.
The system is now without power.
Open or remove the tower bezel
This server has a removable bezel that must be unlocked and opened before accessing the hard drives or removing the access panel. The bezel should be kept closed during normal server operations.
Operations 22
Use the key provided with the server to unlock the bezel with a counterclockwise turn.
If necessary, remove the tower bezel.
Operations 23
The middle panel can be removed to access the Systems Insight Display and I/O bezel.
The top panel can be removed to access the removable media bays.
Extend the server from the rack
IMPORTANT: If the server is installed in a telco rack, remove the server from the rack to access internal components.
1.
Extend the server on the rack rails until the server rail-release latches engage.
WARNING: To reduce the risk of personal injury or equipment damage, be sure that the rack is adequately stabilized before extending a component from the rack.
WARNING: To reduce the risk of personal injury, be careful when pressing the server rail-release latches and sliding the server into the rack. The sliding rails could pinch your fingers.
Operations 24
2.
After performing the installation or maintenance procedure, slide the server into the rack by pressing the server rail-release latches.
Remove the access panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.
To remove the component:
1.
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Operations 25
2. o
Extend the server from the rack (on page 24 ).
Open the locking latch, slide the access panel to the rear of the chassis, and remove the access panel.
If the locking latch is locked, use a T-15 Torx screwdriver to unlock the latch.
Remove fans 1-4
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
IMPORTANT: When installing or replacing server components, one or more fans might need to be removed. To prevent an orderly or immediate server shutdown, HP highly recommends powering down the server during these procedures. To determine if powering down is required, see the specific procedure.
To remove the component:
1.
Power down the server (on page 22 ).
2.
3.
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
o
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
4.
5.
Locate the fan to be removed (" Fans " on page 18 ).
Remove the fan.
Remove fan 5
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
Operations 26
IMPORTANT: When installing or replacing server components, one or more fans might need to be removed. To prevent an orderly or immediate server shutdown, HP highly recommends powering down the server during these procedures. To determine if powering down is required, see the specific procedure.
To remove the component:
1.
Power down the server (on page 22 ).
2.
Do one of the following:
3.
4. o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
Remove the fan from the air baffle.
To replace the component, reverse the removal procedure.
Remove the BBWC battery pack or the FBWC capacitor pack
CAUTION: To prevent a server malfunction or damage to the equipment, do not add or remove the battery pack while an array capacity expansion, RAID level migration, or stripe size migration is in progress.
CAUTION: After the server is powered down, wait 15 seconds and then check the amber LED before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do not remove the cable from the cache module. The cache module is backing up data, and data is lost if the cable is detached.
To remove the component:
1.
Power down the server (on page 22 ).
2.
Do one of the following:
Operations 27
3.
4.
5. o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
Disconnect the cable from the cache module only if the battery pack is not being used to recover data from the server or transfer data to another server.
Remove the battery pack.
To replace the component, reverse the removal procedure.
Remove the air baffle
1.
2.
3.
4.
5.
Power down the server (on page 22 ).
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
o
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Operations 28
6.
Remove the air baffle.
Remove the fan cage
IMPORTANT: When installing or replacing server components, one or more fans might need to be removed. To prevent an orderly or immediate server shutdown, HP highly recommends powering down the server during these procedures. To determine if powering down is required, see the specific procedure.
To remove the component:
1.
Power down the server (on page 22 ).
2.
3.
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
o
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
4.
5.
6.
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Operations 29
7.
Remove the fan cage.
Remove the media bay blank
1.
2.
3.
4.
Power down the server (on page 22 ).
Do one of the following: o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
Remove the media bay blank.
Save the blank for future use.
Operations 30
Remove the DVD-ROM drive
1.
2.
3.
4.
5.
6.
7.
8.
9.
Power down the server (on page 22 ).
Do one of the following: o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
Disconnect and remove the DVD-ROM drive data/power cable. For more information, see "DVD-ROM
drive cabling (on page 110 )."
Remove the DVD-ROM drive.
Remove the hard drive cage blank
1.
2.
Power down the server (on page 22 ).
Do one of the following: o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page 24 ).
Operations 31
3.
Remove the hard drive cage blank.
Operations 32
Setup
Optional installation services
Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a single package. A number of service level options are available to meet your needs.
HP Care Pack Services offer upgraded service levels to expand your standard product warranty with easy-to-buy, easy-to-use support packages that help you make the most of your server investments. Some of the Care Pack services are:
•
Hardware support o
6-Hour Call-to-Repair o o
4-Hour 24x7 Same Day
4-Hour Same Business Day
•
Software support o o
Microsoft®
Linux o o
HP ProLiant Essentials (HP SIM and RDP)
VMWare
•
Integrated hardware and software support o o
Critical Service
Proactive 24 o o
Support Plus
Support Plus 24
•
Startup and implementation services for both hardware and software
For more information on HP Care Pack Services, see the HP website
( http://www.hp.com/services/carepack ).
Rack planning resources
The rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 series racks. For more information on the content of each resource, refer to the rack resource kit documentation.
If you intend to deploy and configure multiple servers in a single rack, refer to the white paper on high-density deployment at the HP website ( http://www.hp.com/products/servers/platforms ).
Setup 33
Optimum environment
When installing the server, select a location that meets the environmental standards described in this section.
Space and airflow requirements
Tower server
In a tower configuration, leave at least a 7.6-cm (3-in) clearance space at the front and back of the server for proper ventilation.
Rack server
To allow for servicing and adequate airflow, observe the following space and airflow requirements when deciding where to install a rack:
•
Leave a minimum clearance of 63.5 cm (25 in) in front of the rack.
•
Leave a minimum clearance of 76.2 cm (30 in) behind the rack.
•
Leave a minimum clearance of 121.9 cm (48 in) from the back of the rack to the back of another rack or row of racks.
HP servers draw in cool air through the front door and expel warm air through the rear door. Therefore, the front and rear rack doors must be adequately ventilated to allow ambient room air to enter the cabinet, and the rear door must be adequately ventilated to allow the warm air to escape from the cabinet.
CAUTION: To prevent improper cooling and damage to the equipment, do not block the ventilation openings.
When vertical space in the rack is not filled by a server or rack component, the gaps between the components cause changes in airflow through the rack and across the servers. Cover all gaps with blanking panels to maintain proper airflow.
CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
The 9000 and 10000 Series Racks provide proper server cooling from flow-through perforations in the front and rear doors that provide 64 percent open area for ventilation.
CAUTION: When using a Compaq branded 7000 Series rack, you must install the high airflow rack door insert [P/N 327281-B21 (42U) or P/N 157847-B21 (22U)] to provide proper front-to-back airflow and cooling.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
•
Front and rear doors—If the 42U rack includes closing front and rear doors, you must allow
5,350 sq cm (830 sq in) of holes evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
• Side—The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 in).
Setup 34
Temperature requirements
To ensure continued safe and reliable equipment operation, install or position the system in a well-ventilated, climate-controlled environment.
The maximum recommended ambient operating temperature (TMRA) for most server products is 35°C
(95°F). The temperature in the room where the rack is located must not exceed 35°C (95°F).
CAUTION: To reduce the risk of damage to the equipment when installing third-party options:
•
Do not permit optional equipment to impede airflow around the server or to increase the internal rack temperature beyond the maximum allowable limits.
• Do not exceed the manufacturer’s TMRA.
Power requirements
Installation of this equipment must comply with local and regional electrical regulations governing the installation of information technology equipment by licensed electricians. This equipment is designed to operate in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992
(code for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the product rating label or the user documentation supplied with that option.
WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over wiring and installation requirements of your facility.
CAUTION: Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible power supply (UPS). This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure.
When installing more than one server, you may need to use additional power distribution devices to safely provide power to all devices. Observe the following guidelines:
•
Balance the server power load between available AC supply branch circuits.
•
Do not allow the overall system AC current load to exceed 80 percent of the branch circuit AC current rating.
•
Do not use common power outlet strips for this equipment.
•
Provide a separate electrical circuit for the server.
Electrical grounding requirements
The server must be grounded properly for proper operation and safety. In the United States, you must install the equipment in accordance with NFPA 70, 1999 Edition (National Electric Code), Article 250, as well as any local and regional building codes. In Canada, you must install the equipment in accordance with
Canadian Standards Association, CSA C22.1, Canadian Electrical Code. In all other countries, you must install the equipment in accordance with any regional or national electrical wiring codes, such as the
International Electrotechnical Commission (IEC) Code 364, parts 1 through 7. Furthermore, you must be sure that all power distribution devices used in the installation, such as branch wiring and receptacles, are listed or certified grounding-type devices.
Setup 35
Because of the high ground-leakage currents associated with multiple servers connected to the same power source, HP recommends the use of a PDU that is either permanently wired to the building’s branch circuit or includes a nondetachable cord that is wired to an industrial-style plug. NEMA locking-style plugs or those complying with IEC 60309 are considered suitable for this purpose. Using common power outlet strips for the server is not recommended.
Rack warnings
WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that:
• The leveling jacks are extended to the floor.
•
The full weight of the rack rests on the leveling jacks.
•
The stabilizing feet are attached to the rack if it is a single-rack installation.
•
The racks are coupled together in multiple-rack installations.
• Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason.
WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack:
•
At least two people are needed to safely unload the rack from the pallet. An empty 42U rack can weigh as much as 115 kg (253 lb), can stand more than 2.1 m (7 ft) tall, and may become unstable when being moved on its casters.
•
Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle the rack from both sides.
WARNING: When installing a server in a telco rack, be sure that the rack frame is adequately secured to the top and bottom of the building structure.
Server warnings and cautions
WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the equipment:
•
Observe local occupational health and safety requirements and guidelines for manual material handling.
• Get help to lift and stabilize the product during installation or removal, especially when the product is not fastened to the rails. When the server weighs more than 22.5 kg (50 lb), at least two people must lift the server into the rack together. A third person may be required to help align the server if the server is installed higher than chest level.
• Use caution when installing the server in or removing the server from the rack; it is unstable when not fastened to the rails.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.
Setup 36
CAUTION: Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible power supply (UPS). This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure.
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.
Identifying tower server shipping carton contents
Unpack the server shipping carton and locate the materials and documentation necessary for installing the server.
The contents of the server shipping carton include:
•
Server
•
Power cord
•
Keyboard
•
Mouse
•
Tower feet
•
Hardware documentation, Documentation CD, and software products
In addition to the supplied items, you may need:
•
Hardware options
•
Operating system or application software
•
PDU
Identifying rack server shipping carton contents
Unpack the server shipping carton and locate the materials and documentation necessary for installing the server. All the rack mounting hardware necessary for installing the server into the rack is included with the rack or the server.
The contents of the server shipping carton include:
•
Server
•
Power cord
•
Hardware documentation, Documentation CD, and software products
•
Rack-mounting hardware
In addition to the supplied items, you may need:
•
Hardware options
•
Operating system or application software
•
PDU
Setup 37
Installing hardware options
Install any hardware options before initializing the server. For options installation information, refer to the
Setting up a tower server
Follow the steps in this section to set up a tower model server. If you are going to install the server into a rack,
refer to the rack installation section (" Installing the server into the rack " on page 39 ).
1.
2.
Place the server on a flat, stable surface.
Install the tower feet.
3.
4.
5.
Connect peripheral devices to the server. (" Rear panel components " on page 11 )
WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into RJ-45 connectors.
Connect the power cord to the rear of the server.
Open the power cord retaining clip, and thread the power cord through the retaining clip.
Setup 38
6.
Push the tab into place to secure the power cord.
7.
Connect the power cord to the AC power source.
WARNING: To reduce the risk of electric shock or damage to the equipment:
•
Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
•
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
• Unplug the power cord from the power supply to disconnect power to the equipment.
• Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.
Installing the server into the rack
To install the server into a rack with square, round, or threaded holes, refer to the instructions that ship with the rack hardware kit.
If you are installing the server into a telco rack, order the appropriate option kit at the RackSolutions.com website ( http://www.racksolutions.com/hp ). Follow the server-specific instructions on the website to install the rack brackets.
CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the rack.
Install the heaviest item first, and continue to populate the rack from the bottom to the top.
Setup 39
1.
2.
WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the equipment:
•
Observe local occupational health and safety requirements and guidelines for manual material handling.
•
Get help to lift and stabilize the product during installation or removal, especially when the product is not fastened to the rails. When the server weighs more than 22.5 kg (50 lb), at least two people must lift the server into the rack together. A third person may be required to help align the server if the server is installed higher than chest level.
•
Use caution when installing the server in or removing the server from the rack; it is unstable when not fastened to the rails.
Install the server and cable management arm into the rack. For more information, refer to the installation instructions that ship with the 3-7U Quick Deploy Rail System (rack installation only).
Connect peripheral devices to the server (" Rear panel components " on page 11 ).
Powering up and configuring the server
To power up the server, press the Power On/Standby button.
While the server boots, RBSU and the ORCA utility are automatically configured to prepare the server for operating system installation.
To configure these utilities manually:
•
Press the F8 key when prompted during the array controller initialization to configure the array controller using ORCA.
•
Press the F9 key when prompted during the boot process to change the server settings using RBSU. The system is set up by default for the English language.
For more information on the automatic configuration, refer to the HP ROM-Based Setup Utility User Guide located on the Documentation CD.
Installing the operating system
To operate properly, the server must have a supported operating system. For the latest information on supported operating systems, refer to the HP website ( http://www.hp.com/go/supportos ).
Two methods are available to install an operating system on the server:
•
SmartStart assisted installation—Insert the SmartStart CD into the CD-ROM drive and reboot the server.
•
Manual installation—Insert the operating system CD into the CD-ROM drive and reboot the server. This process may require you to obtain additional drivers from the HP website
( http://www.hp.com/support ).
Follow the on-screen instructions to begin the installation process.
For information on using these installation paths, refer to the SmartStart installation poster in the HP ProLiant
Essentials Foundation Pack, included with the server.
Registering the server
To register the server, refer to the HP Registration website ( http://register.hp.com
).
Setup 40
Hardware options installation
Introduction
If more than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to streamline the installation process.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge.
Processor option
The server supports single- and dual-processor operation. With two processors installed, the server supports boot functions through the processor installed in processor socket 1. However, if processor 1 fails, the system attempts to boot from processor 2 and provides a processor failure message.
The server uses embedded PPMs to provide power to each processor.
CAUTION: To avoid damage to the processor and system board, only authorized personnel should attempt to replace or install the processor in this server.
CAUTION: To avoid damage to the processor:
•
Handle the processor only by the edges.
• Do not touch the bottom of the processor, especially the contact area.
IMPORTANT: Processor socket 1 must always be populated. If processor socket 1 is empty, the server halts during POST.
To install the component:
1.
2.
Power down the server (on page 22 ).
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
3.
4.
5.
6. o
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
CAUTION: Failure to completely open the processor locking lever prevents the processor from seating during installation, leading to hardware damage.
Hardware options installation 41
7.
Open the processor locking lever and the processor socket retaining bracket. Do not remove the processor socket cover.
IMPORTANT: Be sure the processor remains inside the processor installation tool.
8.
If the processor has separated from the installation tool, carefully re-insert the processor in the tool.
Handle the processor by the edges only, and do not touch the bottom of the processor, especially the contact area.
Hardware options installation 42
9.
Align the processor installation tool with the socket, and then install the processor. THE PINS ON THE
SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED.
CAUTION: THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED. To avoid damage to the system board:
• Never install or remove a processor without using the processor installation tool.
• Do not touch the processor socket contacts.
•
Do not tilt or slide the processor when lowering the processor into the socket.
Hardware options installation 43
10.
Press the tabs on the processor installation tool to separate it from the processor, and then remove the tool.
11.
Close the processor socket retaining bracket and the processor locking lever. The processor socket cover is automatically ejected. Remove the cover.
CAUTION: Be sure to close the processor socket retaining bracket before closing the processor locking lever. The lever should close without resistance. Forcing the lever closed can damage the processor and socket, requiring system board replacement.
Hardware options installation 44
12.
Open the heatsink retaining latches.
13.
Remove the protective cover from the heatsink.
CAUTION: To prevent thermal instability and damage to the server, do not separate the processor from the heatsink after assembling.
Hardware options installation 45
14.
Install the heatsink, and then close the heatsink retaining latches.
15.
16.
17.
18.
19.
20.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o
Close or install the tower bezel, as needed. o
Slide the server back into the rack.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Memory options
IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the server to halt during BIOS initialization.
The memory subsystem in this server can support RDIMMs or UDIMMs. Both types are referred to as DIMMs when the information applies to both types. When specified as RDIMM or UDIMM, the information applies to that type only. All memory installed in the server must be the same type.
The server supports the following DIMM speeds:
•
Single- and dual-rank PC3-10600 (DDR-1333) DIMMs operating at 1333 and 1066 MHz
•
Quad-rank PC3-8500 (DDR-1067) DIMMs operating at 1066 MHz
Depending on the processor model, the number of DIMMs installed, and whether UDIMMs or RDIMMs are installed, the memory clock speed may be reduced to 1066 or 800 MHz. For more information on the effect
of DIMM slot population, see "General DIMM slot population guidelines (on page 50 )."
Hardware options installation 46
Memory subsystem architecture
The memory subsystem in this server is divided into channels. Each processor supports three channels, and each channel supports three DIMM slots, as shown in the following table.
Channel Population order Slot number
1
2
3
H
E
B
G
D
A
I
F
C
4
5
6
1
2
3
7
8
9
This multi-channel architecture provides enhanced performance in Advanced ECC mode. This architecture also enables the Lockstep, Online Spare, and Mirrored Memory modes. This server supports both Registered
PC3 DIMMs (RDIMMs) and Unbuffered DIMMs (UDIMMs).
DIMM slots in this server are identified by number and by letter. Letters identify the slots to populate for specific AMP modes. Slot numbers are reported by ROM messages during boot and for error reporting.
Single-, dual-, and quad-rank DIMMs
To understand and configure memory protection modes properly, an understanding of single-, dual-, and quad-rank DIMMs is helpful. Some DIMM configuration requirements are based on these classifications.
A single-rank DIMM has one set of memory chips that is accessed while writing to or reading from the memory. A dual-rank DIMM is similar to having two single-rank DIMMs on the same module, with only one rank accessible at a time. A quad-rank DIMM is, effectively, two dual-rank DIMMs on the same module. Only one rank is accessible at a time. The server memory control subsystem selects the proper rank within the
DIMM when writing to or reading from the DIMM.
Dual- and quad-rank DIMMs provide the greatest capacity with the existing memory technology. For example, if current DRAM technology supports 2-GB single-rank DIMMs, a dual-rank DIMM would be 4-GB, and a quad-rank DIMM would be 8-GB.
DIMM identification
IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the server to halt during BIOS initialization.
Hardware options installation 47
The memory subsystem may be populated with either RDIMMs or UDIMMs, but mixing the two types is not supported. To determine DIMM characteristics, use the label attached to the DIMM and the following illustration and table.
Item Description
1
2
3
4
5
Size
Rank
Data width
Memory speed
DIMM type
Definition
—
1R = Single-rank
2R = Dual-rank
4R = Quad-rank x4 = 4-bit x8 = 8-bit
10600 = 1333-MHz
8500 = 1066-MHz
R = RDIMM (registered)
E = UDIMM (unbuffered with ECC)
For the latest supported memory information, see the QuickSpecs on the HP website ( http://www.hp.com
).
Memory configurations
To optimize server availability, the server supports the following AMP modes:
•
Advanced ECC—provides the greatest memory capacity for a given DIMM size, while providing up to
4-bit error correction. This mode is the default option for this server.
•
Mirrored Memory—provides maximum protection against failed DIMMs. Uncorrectable errors in one channel are corrected by the mirror channel.
•
Lockstep—provides enhanced protection while making all installed memory available to the operating system. The server can continue to function if a single- or multi-bit memory failure within a single DRAM device occurs.
Advanced Memory Protection options are configured in RBSU. If the requested AMP mode is not supported by the installed DIMM configuration, the server boots in Advanced ECC mode. For more information, see
"HP ROM-Based Setup Utility (on page 116 )."
Hardware options installation 48
For the latest memory configuration information, see the QuickSpecs on the HP website
( http://www.hp.com
).
RDIMM maximum memory configurations
The following table lists the maximum memory configurations possible with 16-GB RDIMMs.
Rank Single-processor Dual-processor
Single-rank
Dual-rank
Quad-rank
36 GB
72 GB
96 GB
72 GB
144 GB
192 GB
UDIMM maximum memory configurations
When using 2-GB single- or dual-rank UDIMMs, the server supports a maximum of 24 GB with one processor and 48 GB with two processors.
Advanced ECC memory configuration
Advanced ECC memory is the default memory protection mode for this server. Standard ECC can correct single-bit memory errors and detect multi-bit memory errors. When multi-bit errors are detected using
Standard ECC, the error is signaled to the server and causes the server to halt.
Advanced ECC protects the server against some multi-bit memory errors. Advanced ECC can correct both single-bit memory errors and 4-bit memory errors if all failed bits are on the same DRAM device on the DIMM.
Advanced ECC provides additional protection over Standard ECC because it is possible to correct certain memory errors that would otherwise be uncorrected and result in a server failure. The server provides notification that correctable error events have exceeded a pre-defined threshold rate.
Lockstep memory configuration
Lockstep mode provides protection against multi-bit memory errors that occur on the same DRAM device.
Lockstep mode can correct any single DRAM device failure on x4 and x8 DIMM types. The DIMMs in each channel must have identical HP part numbers.
Lockstep mode uses channel 1 and channel 2. Channel 3 is not populated. Because channel 3 cannot be populated when using Lockstep mode, the maximum memory capacity is lower than Advanced ECC mode.
Memory performance with Advanced ECC is also slightly higher.
Online Spare memory configuration
Online spare memory provides protection against degraded DIMMs by reducing the likelihood of uncorrected memory errors. This protection is available without any operating system support.
Online spare memory protection dedicates one rank of each memory channel for use as spare memory. The remaining ranks are available for OS and application use. If correctable memory errors occur at a rate higher than a specific threshold on any of the non-spare ranks, the server automatically copies the memory contents of the degraded rank to the online spare rank. The server then deactivates the failing rank and automatically switches over to the online spare rank.
Hardware options installation 49
General DIMM slot population guidelines
Observe the following guidelines for all AMP modes:
•
Populate DIMM slots for a processor only if the processor is installed.
•
To maximize performance in multi-processor configurations, distribute the total memory capacity between all processors as evenly as possible.
•
Do not mix Unbuffered and Registered PC3 DIMMs.
•
Each channel supports up to two Unbuffered DIMMs.
•
If quad-rank DIMMs are installed for a processor, a maximum of two DIMMs can be installed on each channel for that processor.
•
If a channel contains quad-rank DIMMs, the quad-rank DIMM must be installed first on that channel.
DIMM speeds are supported as indicated in the following table.
Populated slots
(per channel)
Rank Speeds supported
(MHz)
1
Single- or dual-rank 1333, 1066
1
Quad-rank 1066
2
Single- or dual-rank 1066
3
Single- or dual-rank 800
Advanced ECC population guidelines
For Advanced ECC mode configurations, observe the following guidelines:
•
Observe the general DIMM slot population guidelines (on page 50 ).
•
DIMMs may be installed individually.
Multi-processor Advanced ECC population order
For Advanced ECC mode configurations with multiple processors, populate the DIMM slots for each processor in the following order:
•
RDIMM: Sequentially in alphabetical order (A through I)
•
UDIMM: A through F, sequentially in alphabetical order. Do not populate DIMM slots G through I.
Single-processor Advanced ECC population order
For Advanced ECC mode configurations with a single processor, populate the DIMM slots in the following order:
•
RDIMM: Sequentially in alphabetical order (A through I)
•
UDIMM: A through F, sequentially in alphabetical order. Do not populate DIMM slots G through I.
Lockstep Memory population guidelines
For Lockstep memory mode configurations, observe the following guidelines:
•
Observe the general DIMM slot population guidelines (on page 50 ).
Hardware options installation 50
•
Always install DIMMs in channels 1 and 2 for each installed processor.
•
Do not install DIMMs in channel 3 for any processor.
•
DIMM configuration on channel 1 and channel 2 of a processor must be identical.
•
In multi-processor configurations, each processor must have a valid Lockstep Memory configuration.
•
In multi-processor configurations, each processor may have a different valid Lockstep Memory configuration.
Single-processor Lockstep population order
For Lockstep memory mode configurations with a single processor, populate the DIMM slots in the following order:
•
RDIMM o
First: A and B o o
Next: D and E
Last: G and H
Do not populate slots C, F, or I. o
•
UDIMM o
First: A and B o o
Last: D and E
Do not populate slots C, F, G, H, or I.
Multi-processor Lockstep population order
For Lockstep memory mode configurations with multiple processors, populate the DIMM slots for each processor in the following order:
•
RDIMM o
First: A and B o o
Next: D and E
Last: G and H
Do not populate slots C, F, or I. o
•
UDIMM o
First: A and B o o
Last: D and E
Do not populate slots C, F, G, H, or I.
Online Spare population guidelines
For Online Spare mode configurations, observe the following guidelines:
Hardware options installation 51
•
Observe the general DIMM slot population guidelines (on page 50 ).
•
DIMM configuration on each channel of a processor must be identical.
•
Each processor must have a valid Online Spare configuration.
•
In multi-processor configurations, each processor can have a different valid Online Spare configuration.
Installing a DIMM
CAUTION: To avoid damage to the hard drives, memory, and other system components, the air baffle, drive blanks, and access panel must be installed when the server is powered up.
1.
2.
3.
4.
5.
6.
7.
8.
Power down the server (on page 22 ).
Do one of the following: o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Open the DIMM slot latches.
Install the DIMM.
9.
10.
11.
12.
Install the air baffle.
Install fan 5.
Install the access panel.
Hardware options installation 52
For more information about LEDs and troubleshooting failed DIMMs, see "Systems Insight Display LED
Redundant fans option
Redundant fan guidelines
The server supports redundant hot-plug fans to provide proper airflow to the system if a primary fan fails.
In the standard, non-redundant, configuration, fans 2, 4, and 5 cool the server.
For the redundant configuration, fans 1 and 3 are added to back up the primary fans. This configuration enables the server to continue operation in non-redundant mode, if a fan failure occurs. The following rules apply:
•
If one fan fails or is removed in non-redundant mode, the server shuts down.
•
If one fan fails or is removed in redundant mode, the server converts to non-redundant mode.
•
If two fans fail or are removed in redundant mode, the server shuts down.
IMPORTANT: When installing or replacing server components, one or more fans might need to be removed. To prevent an orderly or immediate server shutdown, HP highly recommends powering down the server during these procedures. To determine if powering down is required, see the specific procedure.
Installing redundant fans
WARNING: To prevent personal injury from hazardous energy:
• Remove watches, rings, or other metal objects.
• Use tools with insulated handles.
•
Do not place tools or metal parts on top of batteries.
To install the component:
1.
2.
Power down the server (on page 22 ).
Do one of the following:
3.
4. o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
5.
6.
7.
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
Hardware options installation 53
8.
Remove the fan blanks from bay 1 and bay 3. Retain the blanks for future use.
9.
Install the redundant fans.
10.
11.
12.
13.
14.
15.
16.
Install the fan cage.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o o
Close or install the tower bezel, as needed.
Slide the server back into the rack.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Hardware options installation 54
Redundant hot-plug power supply option
The server supports a second hot-plug power supply to provide redundant power to the system if the primary power supply fails.
WARNING: To reduce the risk of electric shock or damage to the equipment:
• Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
•
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
•
Unplug the power cord from the power supply to disconnect power to the equipment.
•
Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the equipment.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply or power supply blank to cool before touching it.
WARNING: To reduce the risk of electric shock or damage to the equipment, do not connect the power cord to the power supply until the power supply is installed.
CAUTION: Always install either a hot-plug power supply or a power supply blank into each bay to maintain proper airflow and cooling in the server. Improper airflow can lead to thermal damage.
Power supply configuration
Label color
CAUTION: All power supplies installed in the server must have the same output power capacity.
Verify that all power supplies have the same part number and label color. The system becomes unstable and may shut down when it detects mismatched power supplies.
Output
Blue
Orange
Green
460W
750W
1,200W
Hot-plug power supply calculations
For more information on the hot-plug power supply and calculators to determine server power consumption in various system configurations, refer to the HP Enterprise Configurator website
( http://h30099.www3.hp.com/configurator/ ).
Hardware options installation 55
Installing a redundant hot-plug power supply
To install the component:
1.
Remove the power supply blank.
2.
Install the second hot-plug power supply.
3.
Connect the power cord to the redundant power supply.
Hardware options installation 56
4.
Use the power cord management clip to secure the cord and form a service loop.
5.
6.
Connect the power cord to the AC power source.
Be sure that the power supply LED is green (" Rear panel LEDs " on page 12 ).
IMPORTANT: For maximum server availability, be sure that the two power supplies are powered by separate AC power sources.
Hot-plug SAS hard drive options
When adding hard drives to the server, observe the following general guidelines:
•
The system automatically sets all device numbers.
•
If only one hard drive is used, install it in the bay with the lowest device number.
•
Drives should be the same capacity to provide the greatest storage space efficiency when drives are grouped together into the same drive array.
Installing a hot-plug SAS hard drive
1.
Remove the SAS hard drive blank.
Hardware options installation 57
2.
Prepare the hard drive.
3.
Install the hard drive.
4.
Determine the status of the hard drive from the hot-plug SAS hard drive LED combinations (" SAS and
SATA hard drive LED combinations " on page 17 ).
Removing a hot-plug SAS hard drive
CAUTION: For proper cooling do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
1.
2.
Determine the status of the hard drive from the hot-plug SAS hard drive LED combinations (" SAS and
SATA hard drive LED combinations " on page 17 ).
Back up all server data on the hard drive.
Hardware options installation 58
3.
Remove the hard drive.
Eight-bay SFF drive cage option
Install the optional eight-bay SFF drive cage in drive cage bay 2 or drive cage bay 3.
To install an additional eight-bay SFF drive cage, an optional SAS controller is required. To obtain the option, contact an HP authorized reseller.
To configure this option for drive cage bay 3, locate the three jumper pins on the backplane. Move the jumper from pins 1 and 2 to pins 2 and 3.
For more information, see "Drive cage jumper configuration settings (on page 21 )."
Installing the eight-bay SFF drive cage (bay 2)
1.
Power down the server (on page 22 ).
2.
3.
4.
5.
6.
7.
8.
9.
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
o
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
Remove the hard drive cage blank (on page 31 ).
Using a T-10 Torx screwdriver, remove the two screws on top of the drive cage.
Hardware options installation 59
Save the screws.
10.
Using the screws, install the eight-bay SFF drive cage.
11.
Connect the SAS cables to an optional SAS controller (" Storage controller option " on page 84 ).
Hardware options installation 60
12.
Route and connect the drive cage bay 2 power cable (BP2) and the SAS cables to the drive cage backplane.
13.
14.
15.
16.
17.
18.
Install the fan cage.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o o
Close or install the tower bezel, as needed.
Slide the server back into the rack.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
19.
20.
Install the hard drives and hard drive blanks.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Installing the eight-bay SFF drive cage (bay 3)
To configure this option for drive cage bay 3, locate the three jumper pins on the backplane. Move the jumper from pins 1 and 2 to pins 2 and 3.
For more information, see "Drive cage jumper configuration settings (on page 21 )."
1.
Power down the server (on page 22 ).
2.
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
3.
4. o
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
Hardware options installation 61
5.
6.
7.
8.
9.
10.
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
Remove the media bay blank (on page 30 ).
Remove the DVD-ROM drive (on page 31 ).
Using a T-10 Torx screwdriver, remove the two screws on top of the drive cage.
11.
Using a T-15 Torx screwdriver, remove the sleeve from the drive cage.
Hardware options installation 62
12.
Install the drive cage.
13.
Using a T-15 Torx screwdriver, install the locking brackets.
14.
Connect the SAS cables to an optional SAS controller (" Storage controller option " on page 84 ).
Hardware options installation 63
15.
Route and connect the drive cage bay 3 power cable (BP3) and the SAS cables to the drive cage backplane.
16.
17.
18.
19.
20.
21.
Install the fan cage.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o o
Close or install the tower bezel, as needed.
Slide the server back into the rack.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
22.
23.
Install the hard drives and hard drive blanks.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Six-bay LFF backplane option
When installing a single six-bay LFF backplane, HP recommends installing it in drive cage bay 1.
When installing a second six-bay LFF backplane, one of the following options is required:
•
An optional SAS controller
•
An optional 24-port SAS expander
To obtain either of these options, contact an HP authorized reseller.
Hardware options installation 64
Installing the six-bay LFF backplane (bay 1)
To install the component:
1.
2.
Power down the server (on page 22 ).
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
3.
4.
5.
6.
7. o
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
8.
9.
10.
Remove any SFF drives installed in bay 1.
Disconnect the power and data cables from the eight-bay SFF drive cage in drive cage bay 1.
Using a T-10 Torx screwdriver, remove the eight-bay SFF drive cage from drive cage bay 1.
Hardware options installation 65
11.
Using a T-15 Torx screwdriver, install the six-bay LFF backplane.
12.
Connect the power cable.
Hardware options installation 66
13.
Route and connect the SAS cables.
14.
15.
16.
17.
18.
19.
Install the fan cage.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o
Close or install the tower bezel, as needed. o
Slide the server back into the rack.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
20.
21.
Install the hard drives and hard drive blanks.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Installing the six-bay LFF backplane (bay 2)
To install the component:
1.
Power down the server (on page 22 ).
2.
Do one of the following:
3.
4.
5.
6. o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Hardware options installation 67
7.
8.
9.
Remove the fan cage (on page 29 ).
Remove the hard drive cage blank (on page 31 ).
Using a T-15 Torx screwdriver, install the six-bay LFF backplane.
10.
Connect the power cable.
The cabling for drive cage bay 1 is not shown for clarity.
11.
optional SAS expander (" HP SAS Expander Card option " on page 87 ).
Hardware options installation 68
12.
Route and connect the SAS cables.
13.
14.
15.
16.
17.
18.
Install the fan cage.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o
Close or install the tower bezel, as needed. o
Slide the server back into the rack.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
19.
20.
Install the hard drives and hard drive blanks.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Two-bay LFF drive cage option
To configure this option for drive cage bay 3, locate the three jumper pins on the backplane. Move the jumper from pins 1 and 2 to pins 2 and 3.
For more information, see "Drive cage jumper configuration settings (on page 21 )."
To install the component:
1.
Power down the server (on page 22 ).
2.
Do one of the following:
3. o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
Hardware options installation 69
4.
5.
6.
7.
8.
9.
10.
11.
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
Remove all SFF drives and the drive cage from bay 3, if installed.
For more information, see the server maintenance and service guide.
Remove the media bay blank (on page 30 ).
Remove the DVD-ROM drive (on page 31 ).
Install the two-bay LFF drive cage.
12.
Using a T-15 Torx screwdriver, install the locking brackets.
Hardware options installation 70
13.
Connect the drive cage bay 3 power cable (BP3) to the two-bay LFF drive cage backplane.
14.
15.
Connect the two-bay LFF drive cage to one of the following: o
A six-bay LFF backplane. See step 15. o
An optional SAS controller. See step 16.
Connect the SAS/SATA controller cable: a. b. c.
Connect the "6LFF" labeled connector to SAS connector 5-6 on the six-bay LFF backplane.
Connect the "2LFF" labeled connector to the two-bay LFF drive cage backplane.
Connect the remaining connector to SAS connector B on the system board.
Hardware options installation 71
d.
Connect the LED cable to the two-bay LFF drive cage backplane and to the six-bay LFF backplane.
16. e.
Proceed to step 17.
Connect the SAS/SATA controller cable: a.
b.
Connect the "6LFF" labeled connector to the two-bay LFF drive cage backplane.
For this cabling scenario, the "2LFF" labeled connector is not used.
17.
18.
19.
20. c.
Coil the excess cable to minimize the impact to airflow.
Install the fan cage.
Install the air baffle.
Install fan 5.
Hardware options installation 72
21.
22.
Install the access panel.
Do one of the following: o o
Close or install the tower bezel, as needed.
Slide the server back into the rack.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.
23.
24.
Install the hard drives and hard drive blanks.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Removable media device options
The server supports the installation of up to two half-height devices or one full-height device in the removable media bays.
Installing a half-height media device
1.
Power down the server (on page 22 ).
2.
3.
4.
5.
6.
7.
8.
9.
Do one of the following: o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
Remove the media bay blank (on page 30 ).
Using a T-15 Torx screwdriver, remove the screws from the blank and install them on the device.
Hardware options installation 73
10.
Slide the media device part of the way into the bay.
11.
12.
13.
14.
15.
16.
17.
18.
19.
Connect the server data and power cables to the rear of the device.
Slide the media drive fully into the bay until it is seated securely.
Install the fan cage.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o o
Close or install the tower bezel, as needed.
Slide the server back into the rack.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Installing a full-height media device
1.
2.
3.
4.
5.
6.
7.
8.
9.
Power down the server (on page 22 ).
Do one of the following: o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
Remove the media bay blank (on page 30 ).
Remove the DVD-ROM drive (on page 31 ).
Hardware options installation 74
10.
Using a T-15 Torx screwdriver, remove the screws from the blank and install them on the device.
11.
Slide the media device part of the way into the bay.
12.
13.
14.
15.
16.
17.
18.
19.
Connect the server data and power cables to the rear of the device.
Slide the media drive fully into the bay until it is seated securely.
Install the fan cage.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o o
Close or install the tower bezel, as needed.
Slide the server back into the rack.
Hardware options installation 75
20.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Slimline optical drive option
To install the component:
1.
Power down the server (on page 22 ).
2.
Do one of the following:
3.
4.
5. o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
6.
7.
8.
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
Remove the optical drive blank.
Hardware options installation 76
9.
Slide the optical drive into the drive bay.
10.
Route and connect the cables: a.
Connect the power and data cable to the optical drive. b. c.
Connect the power cable to an available system power cable.
Route and connect the data cable to the system board.
11.
12.
13.
14.
15.
16.
Install the fan cage.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o
Close or install the tower bezel, as needed. o
Slide the server back into the rack.
Hardware options installation 77
17.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Expansion board options
The server supports up to ten PCIe expansion boards. For more information, see "System board components
IMPORTANT: The HP SAS Expander Card and the HP NC524SFP Adapter are not supported in expansion slot 1.
To install the component:
1.
2.
Power down the server (on page 22 ).
Do one of the following:
3.
4. o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
5.
6.
7.
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Open the expansion board retainer.
Hardware options installation 78
8.
Remove the expansion slot cover.
9.
Install the expansion board.
10.
11.
12.
13.
14.
15.
16.
17.
Close the expansion slot retainer.
Connect any internal cables to the expansion board.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o o
Close or install the tower bezel, as needed.
Slide the server back into the rack.
Connect any external cables to the expansion boards.
Hardware options installation 79
18.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
HP NC524SFP Dual Port 10GbE Module option
When installed on the HP NC375i Integrated Quad Port Multifunction Gigabit Server Adapter, the HP
NC524SFP Dual Port 10GbE Module provides two 10G NIC connectors for server I/O.
If more than one HP NC375i adapter is installed in the server, always install the HP NC524SFP module on the adapter in expansion slot 10.
The HP NC375i adapter supports four NIC connectors at a time. When the HP NC524SFP module is installed, two 1G NIC connectors on the adapter are unavailable.
IMPORTANT: When both an HP NC524SFP module and an optional HP NC522SFP Dual Port
10GbE Server Adapter are installed in the server, only expansion slot 1 has Wake On LAN capability.
To install the component:
1.
Power down the server (on page 22 ).
2.
3.
Disconnect the network cables.
Do one of the following:
4.
5.
6.
7.
8. o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Using a T-15 Torx screwdriver, remove the 10G NIC adapter blank.
Save the retaining screw.
9.
Open the expansion board slot retainer.
Hardware options installation 80
10.
Remove the HP NC375i adapter from expansion slot 10.
11.
Install the HP NC524SFP module on the HP NC375i adapter.
Hardware options installation 81
12.
Install the mini-DIMM on the expansion board.
13.
Install the HP NC375i adapter in expansion slot 10.
14.
Close the expansion board slot retainer.
Hardware options installation 82
15.
Secure the 10G NIC connectors to the chassis with the retaining screw.
16.
Install the RJ-45 plugs on the bottom (rack model) or right (tower model) two RJ-45 connectors on the HP
NC375i adapter.
17.
18.
19.
20.
21.
22.
23.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o
Close or install the tower bezel, as needed. o
Slide the server back into the rack.
Connect the network cables.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Hardware options installation 83
Storage controller option
IMPORTANT: For additional installation and configuration information, refer to the documentation that ships with the option.
To install the component:
1.
2.
Power down the server (on page 22 ).
Do one of the following: o o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page 24 ).
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Install the storage controller (" Expansion board options " on page 78 ).
Connect the hot-plug SAS/SATA cable to the controller.
For connector locations, see the documentation that ships with the controller.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o
Close or install the tower bezel, as needed. o
Slide the server back into the rack.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
BBWC and FBWC options
The server supports either of the following:
•
Battery-backed write cache (BBWC) options
BBWC consists of a cache module and a battery pack (also called a BBWC enabler). The DDR cache module buffers and stores data being written by the controller. When the system is powered on, the battery pack continuously recharges through a trickle-charging process lasting 15 minutes to 2 hours, depending on the original charge. In the event of system power failure, a fully charged battery pack can maintain the cached data for up to 72 hours.
•
Flash-backed write cache (FBWC) options
FBWC consists of a cache module and a capacitor pack. The DDR cache module buffers and stores data being written by the controller. When the system is powered on, the capacitor pack charges fully in about 5 minutes. In the event of a system power failure, a fully charged capacitor pack provides power for up to 80 seconds. During that interval, the controller transfers the cached data from DDR memory to flash memory, where the data remains indefinitely or until a controller retrieves the data.
Hardware options installation 84
CAUTION: Do not use this controller with cache modules designed for other controller models, because the controller can malfunction and you can lose data. Also, do not transfer this cache module to a different controller module, because you can lose data.
CAUTION: To prevent a server malfunction or damage to the equipment, do not add or remove the battery pack while an array capacity expansion, RAID level migration, or stripe size migration is in progress.
CAUTION: After the server is powered down, wait 15 seconds and then check the amber LED before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do not remove the cable from the cache module. The cache module is backing up data, and data is lost if the cable is detached.
IMPORTANT: The battery pack might have a low charge when installed. In this case, a POST error message is displayed when the server is powered up, indicating that the battery pack is temporarily disabled. No action is necessary on your part. The internal circuitry automatically recharges the batteries and enables the battery pack. This process might take up to four hours.
During this time, the cache module functions properly, but without the performance advantage of the battery pack.
NOTE: The data protection and the time limit also apply if a power outage occurs. When power is restored to the system, an initialization process writes the preserved data to the hard drives.
Installing the cache module
CAUTION: Do not use this controller with cache modules designed for other controller models, because the controller can malfunction and you can lose data. Also, do not transfer this cache module to a different controller module, because you can lose data.
To install the component:
1.
Back up all data.
2.
3.
Close all applications.
Power down the server (on page 22 ).
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be powered down and the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up.
4.
5.
Do one of the following: o
Unlock and remove the bezel (" Open or remove the tower bezel " on page 22 ).
o
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
Hardware options installation 85
6.
Install the cache module.
7.
8.
9.
Install the access panel.
Do one of the following: o
Close or install the tower bezel, as needed. o
Slide the server back into the rack.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Installing the BBWC battery pack or the FBWC capacitor pack
CAUTION: Do not use this controller with cache modules designed for other controller models, because the controller can malfunction and you can lose data. Also, do not transfer this cache module to a different controller module, because you can lose data.
To install the component:
1.
Back up all data.
2.
3.
Close all applications.
Power down the server (on page 22 ).
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be powered down and the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up.
4.
5.
6.
7.
Do one of the following: o o
Unlock and remove the bezel (" Open or remove the tower bezel " on page 22 ).
Extend the server from the rack (on page
Remove the access panel (on page 25 ).
Install the cache module (" Installing the cache module " on page 85 ).
Hardware options installation 86
8.
Install the battery pack or the capacitor pack, and then connect the cable to the connector on the top of the cache module.
9.
10.
11.
Install the access panel.
Do one of the following: o
Close or install the tower bezel, as needed. o
Slide the server back into the rack.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
HP SAS Expander Card option
The HP SAS Expander Card is an optional controller that provides up to 24 connectors for internal SAS hard drives.
IMPORTANT: The HP SAS Expander Card is not supported in expansion slot 1.
To install the component:
1.
Power down the server (on page 22 ).
2.
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
3.
4.
5.
6.
7.
8. o
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
Install the plastic bracket on the expander card (optional).
Hardware options installation 87
9.
10.
11.
12.
13.
14.
15.
16.
17.
The plastic bracket ships with the expander card. For more information, see the documentation that ships with the option.
Install the expander card (" Expansion board options " on page 78 ).
Route and connect the cables.
For more information, see the documentation that ships with the expander card.
Install the fan cage.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o o
Close or install the tower bezel, as needed.
Slide the server back into the rack.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Graphics adapter option
The server supports up to three high-power graphics adapters.
Install graphics adapters in the x16 PCIe expansion slots. For more information, see "System board
Before installing a high-power graphics adapter in the server, be sure that the power supplies support the installation of the adapter. Due the high power requirements for the adapter, a 750W or higher power supply may be required. For more information, see the HP Enterprise Configurator website
( http://h30099.www3.hp.com/configurator/ ).
To install the component:
1.
Power down the server (on page 22 ).
2.
3.
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
o
Extend the server from the rack (on page 24 ).
Remove the access panel (on page 25 ).
4.
5.
6.
7.
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
8.
9.
10.
11.
Install the graphics adapter in a x16 PCIe expansion slot (" Expansion board options " on page 78 ).
Connect the power cables.
For more information, see the documentation that ships with the graphics adapter power cable kit.
Install the fan cage.
Install the air baffle.
Hardware options installation 88
12.
13.
14.
15.
16.
Install fan 5.
Install the access panel.
Do one of the following: o
Close or install the tower bezel, as needed. o
Slide the server back into the rack.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Tower-to-rack conversion kit option
The tower-to-rack conversion kit includes all equipment required to convert the tower model server into a rack model server and to install the server into most square- or round-hole racks.
The tower-to-rack conversion kit includes:
•
Rack-mounting hardware kit
•
Rack bezel
•
Front video connector cable
•
T-15 screws (6)
•
Screwlocks (2)
•
This document
In addition to the items supplied in the conversion kit, you will also need the following items:
•
A Torx T-15 screwdriver (clipped to the rear panel of the server)
•
A 3/16-in nut driver
To convert a tower model server to a rack model server:
1.
Power down the server (on page 22 ).
2.
Disconnect all rear panel cabling.
Hardware options installation 89
3.
Remove the feet.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
Remove the tower bezel (" Open or remove the tower bezel " on page 22 ).
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
Remove all SFF hard drives (" Removing a hot-plug SAS hard drive " on page 58 ).
Disconnect all cables from the drive cages.
Remove the SFF drive cages.
For more information, see the server maintenance and service guide.
Remove the hard drive cage blank (on page 31 ).
Remove the DVD-ROM drive (on page 31 ), if installed.
Remove the two-bay LFF drive cage, if installed.
For more information, see the server maintenance and service guide.
(Optional) Reduce the weight of the server: o o o
Remove the power supplies.
Remove all LFF hard drives and blanks.
Disconnect cabling and remove all devices from the removable media bays.
Hardware options installation 90
17.
Extend the Systems Insight Display from the chassis.
18.
For the remaining steps, the Systems Insight Display is not shown for clarity.
With a T-15 Torx screwdriver, remove the following seven screws: o
Inside (4)
Hardware options installation 91
o
Rear (1) o
Front (2)
19.
Remove the chassis from the tower side panels:
Hardware options installation 92
a.
Disengage the chassis from the tower side panels by pushing the bottom side panel back and by pulling the chassis forward. b.
Lift the chassis up and out of the tower side panels.
Hardware options installation 93
20.
With the T-10 Torx screwdriver, remove the tower bezel bracket.
21.
Extend the I/O bezel from the chassis.
22.
Install the rack bezel using the T-15 screws provided.
Hardware options installation 94
The I/O bezel is not shown for clarity.
23.
Remove the front video connector cable blank from the I/O bezel.
Hardware options installation 95
24.
Using a 3/16-in nut driver and the screwlocks, install the front video connector cable.
25.
Route the front video connector cable through the front of the chassis.
Hardware options installation 96
26.
Install the I/O bezel.
27.
28.
Route and connect the front video connector cable to the front video connector on the system board.
Remove the Systems Insight Display cable from the tower slot.
Hardware options installation 97
29.
Route the Systems Insight Display cable into the rack slot.
30.
31.
Connect the Systems Insight Display cable to the Systems Insight Display.
Install the Systems Insight Display.
32.
33.
34.
35.
36.
37.
38.
39.
Install the SFF drive cages.
Install the two-bay LFF drive cage, if removed.
Install the DVD-ROM drive, if removed.
Connect the drive cables.
Install the fan cage.
Install the air baffle.
Install fan 5.
Hardware options installation 98
IMPORTANT: For the system to operate properly in a rack configuration, be sure to change the setting on the system maintenance switch.
40.
41.
42.
43.
44.
45.
Set position 3 on the system maintenance switch to On.
For the location of the system maintenance switch, see the label attached to the access panel.
Install the access panel.
Install the server in the rack.
See the instructions in the rack-mounting hardware kit.
Install the following items: o
Hard drives and blanks o o
Media blank
Power supplies
Connect all rear panel cabling.
Power up the server.
HP Trusted Platform Module option
Use these instructions to install and enable a TPM on a supported server. This procedure includes three sections:
1.
Installing the Trusted Platform Module board (on page 100 ).
2.
3.
Retaining the recovery key/password (on page 101 ).
Enabling the Trusted Platform Module (on page 101 ).
Enabling the TPM requires accessing the ROM-Based Setup Utility (RBSU) (" HP ROM-Based Setup
Utility " on page 116 ). For more information about RBSU, see the HP website
( http://www.hp.com/support/smartstart/documentation ).
TPM installation requires the use of drive encryption technology, such as the Microsoft® Windows®
BitLocker™ Drive Encryption feature. For more information on BitLocker™, see the Microsoft website
( http://www.microsoft.com
).
CAUTION: Always observe the guidelines in this document. Failure to follow these guidelines can cause hardware damage or halt data access.
When installing or replacing a TPM, observe the following guidelines:
•
Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system board.
•
When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption technology. For security reasons, only the customer can enable these features.
•
When returning a system board for service replacement, do not remove the TPM from the system board.
When requested, HP Service provides a TPM with the spare system board.
•
Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.
•
When using BitLocker™, always retain the recovery key/password. The recovery key/password is required to enter Recovery Mode after BitLocker™ detects a possible compromise of system integrity.
Hardware options installation 99
•
HP is not liable for blocked data access caused by improper TPM use. For operating instructions, see the encryption technology feature documentation provided by the operating system.
Installing the Trusted Platform Module board
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Power down the server (on page 22 ).
Do one of the following: o
Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 22 ).
o
Extend the server from the rack (on page 24 ).
Remove the server from the rack, if necessary.
Place the server on a flat, level work surface.
Remove the access panel (on page 25 ).
If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page 27 ).
Remove the air baffle (on page 28 ).
Remove the fan cage (on page 29 ).
CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.
10.
Hardware options installation 100
11.
Install the TPM security rivet by pressing the rivet firmly into the system board.
12.
13.
14.
15.
16.
17.
18.
Install the fan cage.
Install the air baffle.
Install fan 5.
Install the access panel.
Do one of the following: o
Close or install the tower bezel, as needed. o
Install the server in the rack.
Power up the server (on page 22 , "
Powering up and configuring the server " on page 40 ).
Retaining the recovery key/password
The recovery key/password is generated during BitLocker™ setup, and can be saved and printed after
BitLocker™ is enabled. When using BitLocker™, always retain the recovery key/password. The recovery key/password is required to enter Recovery Mode after BitLocker™ detects a possible compromise of system integrity.
To help ensure maximum security, observe the following guidelines when retaining the recovery key/password:
•
Always store the recovery key/password in multiple locations.
•
Always store copies of the recovery key/password away from the server.
•
Do not save the recovery key/password on the encrypted hard drive.
Enabling the Trusted Platform Module
1.
2.
When prompted during the start-up sequence, access RBSU by pressing the F9 key.
From the Main Menu, select Server Security.
Hardware options installation 101
6.
7.
8.
3.
4.
5.
From the Server Security Menu, select Trusted Platform Module.
From the Trusted Platform Module Menu, select TPM Functionality.
Select Enable, and then press the Enter key to modify the TPM Functionality setting.
Press the Esc key to exit the current menu, or press the F10 key to exit RBSU.
Reboot the server.
Enable the TPM in the OS. For OS-specific instructions, see the OS documentation.
CAUTION: When a TPM is installed and enabled on the server, data access is locked if you fail to follow the proper procedures for updating the system or option firmware, replacing the system board, replacing a hard drive, or modifying OS application TPM settings.
For more information on firmware updates and hardware procedures, see the HP Trusted Platform Module
Best Practices White Paper on the HP website ( http://www.hp.com/support ).
For more information on adjusting TPM usage in BitLocker™, see the Microsoft website
( http://technet.microsoft.com/en-us/library/cc732774.aspx
).
Hardware options installation 102
Cabling
Storage device cabling guidelines
CAUTION: To prevent damage to the equipment, be sure that the server is powered down, all cables are disconnected from the back of the server, and the power cord is disconnected from the grounded (earthed) AC outlet before installing devices.
CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge.
Data cabling
Server data cabling
Item
1
2
Description
SATA connector
SAS connector A
Cabling 103
Item
5
6
3
4
Description
SAS connector B
DVD-ROM drive
Hard drive cage 1, SAS connector 2
Hard drive cage 1, SAS connector 1
SAS hard drive cabling
Item
7
8
9
10
3
4
1
2
5
6
11
12
Description
Optional SAS controller 1, port 1
Optional SAS controller 1, port 2
Optional SAS controller 2, connector 1
Optional SAS controller 2, connector 2
SAS connector A
SAS connector B
Hard drive cage 3, SAS connector 2
Hard drive cage 3, SAS connector 1
Hard drive cage 2, SAS connector 2
Hard drive cage 2, SAS connector 1
Hard drive cage 1, SAS connector 2
Hard drive cage 1, SAS connector 1
Cabling 104
Two-bay LFF drive cage cabling
•
Two-bay LFF drive cage cabling to an optional six-bay LFF backplane
Item
3
4
5
1
2
Description
Drive cage bay 1 power cable
Drive cage bay 3 power cable
SAS cable (connector A)
SAS cable (connector B)
LED cable
•
Two-bay LFF drive cage cabling to an optional SAS controller
Cabling 105
Six-bay LFF backplane cabling
•
Drive cage bay 1
•
Drive cage bay 2
Cabling 106
Eight-bay SFF drive cage cabling
•
Drive cage bay 1
•
Drive cage bay 2
Cabling 107
•
Drive cage bay 3
SAS expander cabling
The colors are shown for illustration purposes only.
Item Description
1
SAS expander card, connectors C and D
Cabling 108
Item
6
7
8
4
5
2
3
Description
SAS expander card, connectors E and F
SAS expander card, connectors G and H
SAS expander card, connectors A and B
System board SAS connectors A and B
Hard drive cage 3
Hard drive cage 2
Hard drive cage 1
Media device data cabling
Item
1
2
3
4
Description
SATA connectors
Slimline optical drive
DVD-ROM drive
Half-height media device
Cabling 109
DVD-ROM drive cabling
Slimline optical drive cabling
Cabling 110
Power cabling
Server power cabling (basic configuration)
Item
3
4
1
2
Description
Power supply backplane connector
24-pin power connector
Hard drive cage 1
DVD-ROM drive
Cabling 111
Server power cabling (maximum configuration)
5
6
7
8
3
4
1
2
9
10
11
12
The colors are shown for illustration purposes only.
Item Description
Video card, slot 6
Video card, slot 8
Power connector
Power supply backplane connector
24-pin power connector
Hard drive cage 1
Hard drive cage 2
Half-height media device
DVD-ROM drive
Slimline optical drive
P9 power connector
P12 power connector
Cabling 112
Hard drive cage power cabling
Item
3
4
1
2
5
Description
24-pin power connector
Power supply backplane connector
Hard drive bay 1 (must use BP1 power cable)
Hard drive bay 2 (must use BP2 power cable)
Hard drive bay 3 (must use BP3 power cable)
Cabling 113
Front panel cabling
Item
3
4
1
2
Description
Front USB connector
Front video connector
Systems Insight Display connector
Front panel connector
Cabling 114
BBWC battery pack and FBWC capacitor pack cabling
Cabling 115
Software and configuration utilities
Configuration tools
SmartStart software
SmartStart is a collection of software that optimizes single-server setup, providing a simple and consistent way to deploy server configuration. SmartStart has been tested on many ProLiant server products, resulting in proven, reliable configurations.
SmartStart assists the deployment process by performing a wide range of configuration activities, including:
•
Preparing the system for installing "off-the-shelf" versions of leading operating system software
•
Installing optimized server drivers, management agents, and utilities automatically with every assisted installation
•
•
Installing software drivers directly from the CD. With systems that have Internet connection, the
SmartStart Autorun Menu provides access to a complete list of ProLiant system software.
•
Enabling access to the Array Configuration Utility (on page 119
) and Erase Utility (on page 122 )
SmartStart is included in the HP Insight Foundation suite for ProLiant. For more information about SmartStart software, see the HP Insight Foundation suite for ProLiant or the HP website
( http://www.hp.com/go/foundation ).
SmartStart Scripting Toolkit
The SmartStart Scripting Toolkit is a server deployment product that allows you to build an unattended automated installation for high-volume server deployments. The SmartStart Scripting Toolkit is designed to support ProLiant BL, ML, DL, and SL servers. The toolkit includes a modular set of utilities and important documentation that describes how to apply these tools to build an automated server deployment process.
The Scripting Toolkit provides a flexible way to create standard server configuration scripts. These scripts are used to automate many of the manual steps in the server configuration process. This automated server configuration process cuts time from each deployment, making it possible to scale rapid, high-volume server deployments.
For more information, and to download the SmartStart Scripting Toolkit, see the HP website
( http://www.hp.com/servers/sstoolkit ).
HP ROM-Based Setup Utility
RBSU is a configuration utility embedded in ProLiant servers that performs a wide range of configuration activities that can include the following:
•
Configuring system devices and installed options
•
Enabling and disabling system features
Software and configuration utilities 116
•
Displaying system information
•
Selecting the primary boot controller
•
Configuring memory options
•
Language selection
For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/smartstart/documentation ).
Using RBSU
To use RBSU, use the following keys:
•
To access RBSU, press the F9 key during power-up when prompted.
•
To navigate the menu system, use the arrow keys.
•
To make selections, press the Enter key.
•
To access Help for a highlighted configuration option, press the F1 key.
IMPORTANT: RBSU automatically saves settings when you press the Enter key. The utility does not prompt you for confirmation of settings before you exit the utility. To change a selected setting, you must select a different setting and press the Enter key.
Default configuration settings are applied to the server at one of the following times:
•
Upon the first system power-up
•
After defaults have been restored
Default configuration settings are sufficient for proper typical server operation, but configuration settings can be modified using RBSU. The system will prompt you for access to RBSU with each power-up.
Auto-configuration process
The auto-configuration process automatically runs when you boot the server for the first time. During the power-up sequence, the system ROM automatically configures the entire system without needing any intervention. During this process, the ORCA utility, in most cases, automatically configures the array to a default setting based on the number of drives connected to the server.
NOTE: The server may not support all the following examples.
NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically configure the array. You must run ORCA to configure the array settings.
Drives installed
1
2
3, 4, 5, or 6
More than 6
Drives used
1
2
3, 4, 5, or 6
0
RAID level
RAID 0
RAID 1
RAID 5
None
To change any ORCA default settings and override the auto-configuration process, press the F8 key when prompted.
Software and configuration utilities 117
For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/smartstart/documentation ).
Boot options
Near the end of the boot process, the boot options screen is displayed. This screen is visible for several seconds before the system attempts to boot from a supported boot device. During this time, you can do the following:
•
Access RBSU by pressing the F9 key.
•
Access the System Maintenance Menu (which enables you to launch ROM-based Diagnostics or
Inspect) by pressing the F10 key.
•
Access the boot menu by pressing the F11 key.
•
Force a PXE Network boot by pressing the F12 key.
BIOS Serial Console
BIOS Serial Console allows you to configure the serial port to view POST error messages and run RBSU remotely through a serial connection to the server COM port. The server that you are remotely configuring does not require a keyboard and mouse.
For more information about BIOS Serial Console, see the BIOS Serial Console User Guide on the
Documentation CD or the HP website ( http://www.hp.com/support/smartstart/documentation ).
Configuring AMP modes
Not all ProLiant servers support all AMP modes. RBSU provides menu options only for the modes supported by the server. Advanced memory protection within RBSU enables the following advanced memory.
•
Advanced ECC Mode—Provides memory protection beyond Standard ECC. All single-bit failures and some multi-bit failures can be corrected without resulting in system downtime.
•
Online Spare Mode—Provides protection against failing or degraded DIMMs. Certain memory is set aside as spare, and automatic failover to spare memory occurs when the system detects a degraded
DIMM. DIMMs that are likely to receive a fatal/uncorrectable memory error are removed from operation automatically, resulting in less system downtime.
See the server-specific user guide for DIMM population requirements.
•
Mirrored Memory Mode—Provides protection against uncorrectable memory errors that would otherwise result in system failure. In this mode, the system maintains two copies of all data. If an uncorrectable memory error occurs, the system automatically retrieves the good data from the mirrored copy. The system continues to operate normally without any user intervention. If the system supports hot-plug memory, the failed memory can be replaced while the system continues to operate.
•
RAID Memory Mode—Provides protection levels similar to Mirrored Memory Mode, and it requires less memory allocation than full redundancy.
Configuring mirrored memory
To configure mirrored memory:
1.
Install the required DIMMs (" Installing a DIMM " on page 52 ).
2.
Access RBSU by pressing the F9 key during power-up when the prompt is displayed.
Software and configuration utilities 118
3.
4.
5.
6.
7.
Select System Options.
Select Advanced Memory Protection.
Select Mirrored Memory with Advanced ECC Support.
Press the Enter key.
Press the Esc key to exit the current menu or press the F10 key to exit RBSU.
For more information on mirrored memory, see the white paper on the HP website
( http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html
).
Configuring Advanced ECC memory
To configure Advanced ECC memory:
1.
2.
Install the required DIMMs (" Installing a DIMM " on page 52 ).
When the prompt appears, access RBSU by pressing the F9 key during power-up.
3.
4.
Select System Options.
Select Advanced Memory Protection.
5.
6.
7.
Select Advanced ECC Memory.
Press the Enter key.
Press the Esc key to exit the current menu or press the F10 key to exit RBSU.
For more information on Advanced ECC, see the HP website
( http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html
).
Configuring lockstep memory
To configure Lockstep memory:
1.
2.
Install the required DIMMs (" Installing a DIMM " on page 52 ).
Access RBSU by pressing the F9 key during power-up when the prompt is displayed.
3.
4.
Select System Options.
Select Advanced Memory Protection.
5.
6.
7.
Select Lockstep with Advanced ECC Support.
Press the Enter key.
Press the Esc key to exit the current menu, or press the F10 key to exit RBSU.
For more information on Lockstep memory, see the white paper on the HP website
( http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html
).
Array Configuration Utility
ACU is a browser-based utility with the following features:
•
Runs as a local application or remote service
•
Supports online array capacity expansion, logical drive extension, assignment of online spares, and
RAID or stripe size migration
•
Suggests the optimum configuration for an unconfigured system
Software and configuration utilities 119
•
Provides different operating modes, enabling faster configuration or greater control over the configuration options
•
Remains available any time that the server is on
•
Displays on-screen tips for individual steps of a configuration procedure
•
Beginning with ACU version 8.28.13.0, provides diagnostic functionality on the Diagnostics tab
(formerly known as Array Diagnostics Utility).
For optimum performance, the minimum display settings are 1024 × 768 resolution and 16-bit color. Servers running Microsoft® operating systems require one of the following supported browsers:
•
Internet Explorer 6.0 or later
•
Mozilla Firefox 2.0 or later
For Linux servers, see the README.TXT file for additional browser and support information.
For more information, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the
Documentation CD or the HP website ( http://www.hp.com
).
Option ROM Configuration for Arrays
Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign
RAID levels, and establish online spare configurations.
The utility also provides support for the following functions:
•
Reconfiguring one or more logical drives
•
Viewing the current logical drive configuration
•
Deleting a logical drive configuration
•
Setting the controller to be the boot controller
If you do not use the utility, ORCA will default to the standard configuration.
For more information regarding array controller configuration, refer to the controller user guide.
For more information regarding the default configurations that ORCA uses, refer to the HP ROM-Based Setup
Utility User Guide on the Documentation CD.
Re-entering the server serial number and product ID
After you replace the system board, you must re-enter the server serial number and the product ID.
1.
2.
3.
During the server startup sequence, press the F9 key to access RBSU.
Select the Advanced Options menu.
Select Service Options.
4.
5.
Select Serial Number. The following warnings appear:
WARNING! WARNING! WARNING! The serial number is loaded into the system during the manufacturing process and should NOT be modified. This option should only be used by qualified service personnel. This value should always match the serial number sticker located on the chassis.
Warning: The serial number should ONLY be modified by qualified personnel.
This value should always match the serial number located on the chassis.
Press the Enter key to clear the warning.
Software and configuration utilities 120
6.
7.
8.
9.
10.
11.
Enter the serial number and press the Enter key.
Select Product ID. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified personnel. This value should always match the Product ID on the chassis.
Enter the product ID and press the Enter key.
Press the Esc key to close the menu.
Press the Esc key to exit RBSU.
Press the F10 key to confirm exiting RBSU. The server automatically reboots.
Management tools
Automatic Server Recovery
ASR is a feature that causes the system to restart when a catastrophic operating system error occurs, such as a blue screen, ABEND, or panic. A system fail-safe timer, the ASR timer, starts when the System Management driver, also known as the Health Driver, is loaded. When the operating system is functioning properly, the system periodically resets the timer. However, when the operating system fails, the timer expires and restarts the server.
ASR increases server availability by restarting the server within a specified time after a system hang or shutdown. At the same time, the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system. You can disable ASR from the HP SIM console or through RBSU.
ROMPaq utility
The ROMPaq utility enables you to upgrade the system firmware (BIOS). To upgrade the firmware, insert a
ROMPaq USB Key into an available USB port and boot the system. In addition to ROMPaq, Online Flash
Components for Windows and Linux operating systems are available for updating the system firmware.
The ROMPaq utility checks the system and provides a choice (if more than one exists) of available firmware revisions.
For more information, see the Download drivers and software page for the server. To access the server-specific page, enter the following web address into the browser: http://www.hp.com/support/<servername>
For example: http://www.hp.com/support/dl360g6
Integrated Lights-Out 2 technology
The iLO 2 subsystem is a standard component of selected ProLiant servers that provides server health and remote server manageability. The iLO 2 subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. This design makes iLO 2 independent of the host server and its operating system.
In addition to remote management features, iLO 2 is also responsible for managing the health of the ProLiant server. The intelligence of iLO 2 manages the Sea of Sensors thermal control, directs the Dynamic Power
Capping technology, and monitors the health of server components.
Software and configuration utilities 121
The iLO 2 subsystem provides secure remote access from any authorized network client. The enhancements to iLO 2 enable customers to get work done faster by providing turbo-charged remote access performance, a streamlined user experience, and enhanced standards support.
Using iLO 2, you can do the following:
•
Access a high-performance and secure Remote Console to the server from anywhere in the world.
•
Use the shared iLO 2 Remote Console to collaborate with up to six server administrators.
•
Remotely mount high-performance Virtual Media devices to the server.
•
Securely and remotely control the power state of the managed server.
•
Send alerts from iLO 2 regardless of the state of the host server.
•
Access advanced troubleshooting features through the iLO 2 interface.
For more information about iLO 2 features (which may require an iLO Advanced Pack or iLO Advanced for
BladeSystem license), see the iLO 2 documentation on the Documentation CD or on the HP website
( http://www.hp.com/go/ilo ).
Erase Utility
CAUTION: Perform a backup before running the System Erase Utility. The utility sets the system to its original factory state, deletes the current hardware configuration information, including array setup and disk partitioning, and erases all connected hard drives completely. Refer to the instructions for using this utility.
Run the Erase Utility if you must erase the system for the following reasons:
•
You want to install a new operating system on a server with an existing operating system.
•
You encounter an error when completing the steps of a factory-installed operating system installation.
Redundant ROM support
The server enables you to upgrade or configure the ROM safely with redundant ROM support. The server has a single ROM that acts as two separate ROM images. In the standard implementation, one side of the ROM contains the current ROM program version, while the other side of the ROM contains a backup version.
NOTE: The server ships with the same version programmed on each side of the ROM.
Safety and security benefits
When you flash the system ROM, ROMPaq writes over the backup ROM and saves the current ROM as a backup, enabling you to switch easily to the alternate ROM version if the new ROM becomes corrupted for any reason. This feature protects the existing ROM version, even if you experience a power failure while flashing the ROM.
Software and configuration utilities 122
USB support
HP provides both standard USB 2.0 support and legacy USB 2.0 support. Standard support is provided by the OS through the appropriate USB device drivers. Before the OS loads, HP provides support for USB devices through legacy USB support, which is enabled by default in the system ROM.
Legacy USB support provides USB functionality in environments where USB support is not available normally.
Specifically, HP provides legacy USB functionality for the following:
•
POST
•
RBSU
•
Diagnostics
•
DOS
•
Operating environments which do not provide native USB support
Diagnostic tools
HP Insight Diagnostics
HP Insight Diagnostics is a proactive server management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server installations, troubleshoot problems, and perform repair validation.
HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the OS is not running. To run this utility, launch the SmartStart CD.
HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and other related data needed for effective server management. Available in Microsoft® Windows® and Linux versions, the utility helps to ensure proper system operation.
For more information or to download the utility, refer to the HP website ( http://www.hp.com/servers/diags ).
HP Insight Diagnostics survey functionality
software information on ProLiant servers.
This functionality supports operating systems that may not be supported by the server. For operating systems supported by the server, see the HP website ( http://www.hp.com/go/supportos ).
If a significant change occurs between data-gathering intervals, the survey function marks the previous information and overwrites the survey data files to reflect the latest changes in the configuration.
Survey functionality is installed with every SmartStart-assisted HP Insight Diagnostics installation, or it can be
installed through the HP PSP (" ProLiant Support Packs " on page 125 ).
NOTE: The current version of SmartStart provides the memory spare part numbers for the server.
To download the latest version, see the HP website ( http://www.hp.com/support ).
Software and configuration utilities 123
Integrated Management Log
The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each event with 1-minute granularity.
You can view recorded events in the IML in several ways, including the following:
•
From within HP SIM
•
From within Survey Utility
•
From within operating system-specific IML viewers o
For NetWare: IML Viewer o o
For Windows®: IML Viewer
For Linux: IML Viewer Application
•
From within the iLO 2 user interface
•
From within HP Insight Diagnostics (on page 123 )
For more information, see the Management CD in the HP Insight Foundation suite for ProLiant.
Remote support and analysis tools
HP Insight Remote Support software
HP strongly recommends that you install HP Insight Remote Support software to complete the installation or upgrade of your product and to enable enhanced delivery of your HP Warranty, HP Care Pack Service, or
HP contractual support agreement. HP Insight Remote Support supplements your monitoring 24 x 7 to ensure maximum system availability by providing intelligent event diagnosis, and automatic, secure submission of hardware event notifications to HP, which will initiate a fast and accurate resolution, based on your product’s service level. Notifications may be sent to your authorized HP Channel Partner for on-site service, if configured and available in your country. The software is available in two variants:
•
HP Insight Remote Support Standard: This software supports server and storage devices and is optimized for environments with 1–50 servers. Ideal for customers who can benefit from proactive notification but do not need proactive service delivery and integration with a management platform.
•
HP Insight Remote Support Advanced: This software provides comprehensive remote monitoring and proactive service support for nearly all HP servers, storage, network, and SAN environments, plus selected non-HP servers that have a support obligation with HP. It is integrated with HP Systems Insight
Manager. A dedicated server is recommended to host both HP Systems Insight Manager and HP Insight
Remote Support Advanced.
Details for both versions are available on the HP website ( http://www.hp.com/go/insightremotesupport ).
To download the software, go to Software Depot ( http://www.software.hp.com
).
Select Insight Remote Support from the menu on the right.
Software and configuration utilities 124
Keeping the system current
Drivers
IMPORTANT: Always perform a backup before installing or updating device drivers.
The server includes new hardware that may not have driver support on all OS installation media.
Path feature to install the OS and latest driver support.
If you are installing drivers from the SmartStart CD, be sure that you are using the latest SmartStart version that your server supports. To verify that your server is using the latest supported version, see the HP website
( http://www.hp.com/support ). For more information, see the documentation provided with the SmartStart
CD.
If you do not use the SmartStart CD to install an OS, drivers for some of the new hardware are required.
These drivers, as well as other option drivers, ROM images, and value-add software can be downloaded from the HP website ( http://www.hp.com/support ).
To directly locate the OS drivers for a particular server, enter the following web address into the browser: http://www.hp.com/support/<servername>
In place of <servername>, enter the server name.
For example: http://www.hp.com/support/dl360g6 ( http://www.hp.com/support/dl360g6 )
Version control
The VCRM and VCA are Web-enabled Insight Management Agents tools that HP SIM uses to facilitate and schedule software update tasks to the entire enterprise.
•
VCRM manages the repository for Windows and Linux PSPs as well as online firmware. Administrators can browse a graphical view of the PSPs or configure VCRM to automatically update the repository with
Internet downloads of the latest software from HP.
•
VCA compares installed software versions and available updates. Administrators can configure VCA to point to a repository managed by VCRM.
For more information about version control tools, see the HP Systems Insight Manager Help Guide and the
Version Control User Guide on the HP Systems Insight Manager website ( http://www.hp.com/go/hpsim ).
ProLiant Support Packs
PSPs represent operating system-specific bundles of ProLiant optimized drivers, utilities, and management agents. Refer to the PSP website ( http://h18000.www1.hp.com/products/servers/management/psp.html
).
Software and configuration utilities 125
Operating System Version Support
For information about specific versions of a supported operating system, refer to the operating system support matrix ( http://www.hp.com/go/supportos ).
Firmware
The Smart Update Firmware DVD is an organized firmware collection for ProLiant servers and options
powered by HP Smart Update Manager (on page 126 ). The Smart Update Firmware DVD combines the
following resources on a single DVD:
•
Firmware Maintenance CD
•
HP BladeSystem Firmware Deployment Tool (FDT)
•
The HP BladeSystem online firmware bundles
•
The ProLiant BladeSystem Release Sets
•
Offline, automatic mode for HP ProLiant BL, DL, ML, and 100 Series servers
•
Firmware deployment support for HP ProLiant 100 Series servers
HP Smart Update Manager
The HP Smart Update Manager provides intelligent and flexible firmware and software deployment. This technology assists in reducing the complexity of provisioning and updating HP ProLiant Servers, options, and
Blades within the datacenter. HP SUM is delivered on The Smart Update Firmware DVD, ProLiant Support
Packs, and Easy Set-up CDs.
HP SUM enables system administrators to upgrade ROM images efficiently across a wide range of servers and options. This tool has the following features:
•
Enables GUI and a command-line, scriptable interface
•
Enables scriptable, command-line deployment
•
Requires no agent for remote installations
•
Enables dependency checking, which ensures appropriate install order and dependency checking between components
•
Deploys software and firmware on Windows and Linux operating systems
•
Performs local or remote (one-to-many) online deployment
•
Deploys firmware and software together
•
Supports offline and online deployment
•
Deploys necessary component updates only (except Linux RPMs)
•
Downloads the latest components from Web (except Linux RPMs)
•
Enables direct update of BMC firmware (iLO and LO100i)
For more information about HP Smart Update Manager and to access the HP Smart Update Manager User
Guide, see the HP website ( http://www.hp.com/go/foundation ).
Software and configuration utilities 126
Change control and proactive notification
HP offers Change Control and Proactive Notification to notify customers 30 to 60 days in advance of upcoming hardware and software changes on HP commercial products.
For more information, refer to the HP website ( http://www.hp.com/go/pcn ).
Care Pack
HP Care Pack Services offer upgraded service levels to extend and expand bundled services with easy-to-buy, easy-to-use support packages that help you make the most of your server investments. For more information, see the HP website ( http://www.hp.com/services/carepack ).
Software and configuration utilities 127
Troubleshooting
Troubleshooting resources
The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, error message interpretation, issue resolution, and software maintenance on ProLiant servers and server blades. This guide includes problem-specific flowcharts to help you navigate complex troubleshooting processes. To view the guide, select a language:
•
English ( http://www.hp.com/support/ProLiant_TSG_en )
•
French ( http://www.hp.com/support/ProLiant_TSG_fr )
•
Italian ( http://www.hp.com/support/ProLiant_TSG_it )
•
Spanish ( http://www.hp.com/support/ProLiant_TSG_sp )
•
German ( http://www.hp.com/support/ProLiant_TSG_gr )
•
Dutch ( http://www.hp.com/support/ProLiant_TSG_nl )
•
Japanese ( http://www.hp.com/support/ProLiant_TSG_jp )
Pre-diagnostic steps
WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components.
IMPORTANT: This guide provides information for multiple servers. Some information may not apply to the server you are troubleshooting. Refer to the server documentation for information on procedures, hardware options, software tools, and operating systems supported by the server.
1.
2.
3.
4.
Review the important safety information (on page 128 ).
Gather symptom information (on page 130 ).
Prepare the server for diagnosis (on page 130 ).
Use the Start diagnosis flowchart (on page 133 ) to begin the diagnostic process.
Important safety information
Familiarize yourself with the safety information in the following sections before troubleshooting the server.
Important safety information
Before servicing this product, read the Important Safety Information document provided with the server.
Troubleshooting 128
Symbols on equipment
The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions.
This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.
This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure.
This symbol on an RJ-45 receptacle indicates a network interface connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle.
This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching.
49-109 kg
100-240 lb
This symbol indicates that the component exceeds the recommended weight for one individual to handle safely.
WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling.
These symbols, on power supplies or systems, indicate that the equipment is supplied by multiple sources of power.
WARNING: To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system.
Warnings and cautions
WARNING: Only authorized technicians trained by HP should attempt to repair this equipment.
All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.
WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that:
•
The leveling feet are extended to the floor.
• The full weight of the rack rests on the leveling feet.
•
The stabilizing feet are attached to the rack if it is a single-rack installation.
•
The racks are coupled together in multiple-rack installations.
• Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason.
Troubleshooting 129
WARNING: To reduce the risk of electric shock or damage to the equipment:
•
Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
• Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
•
Unplug the power cord from the power supply to disconnect power to the equipment.
• Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.
49-109 kg
100-240 lb
WARNING: To reduce the risk of personal injury or damage to the equipment:
• Observe local occupation health and safety requirements and guidelines for manual handling.
•
Obtain adequate assistance to lift and stabilize the chassis during installation or removal.
• The server is unstable when not fastened to the rails.
• When mounting the server in a rack, remove the power supplies and any other removable module to reduce the overall weight of the product.
CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the server.
CAUTION: The server is designed to be electrically grounded (earthed). To ensure proper operation, plug the AC power cord into a properly grounded AC outlet only.
Symptom information
Before troubleshooting a server problem, collect the following information:
•
What events preceded the failure? After which steps does the problem occur?
•
What has been changed since the time the server was working?
•
Did you recently add or remove hardware or software? If so, did you remember to change the appropriate settings in the server setup utility, if necessary?
•
How long has the server exhibited problem symptoms?
•
If the problem occurs randomly, what is the duration or frequency?
To answer these questions, the following information may be useful:
•
to compare it to previous configurations.
•
Refer to your hardware and software records for information.
•
Refer to server LEDs and their statuses.
Prepare the server for diagnosis
1.
Be sure the server is in the proper operating environment with adequate power, air conditioning, and humidity control. For required environmental conditions, see the server documentation.
Troubleshooting 130
2.
3.
4.
5.
6.
Record any error messages displayed by the system.
Remove all diskettes, CD-ROMs, DVD-ROMs, and USB drive keys.
Power down the server and peripheral devices if you will be diagnosing the server offline. If possible, always perform an orderly shutdown: a. b.
Exit any applications.
Exit the operating system. c.
Power down the server (on page 22 ).
Disconnect any peripheral devices not required for testing (any devices not necessary to power up the server). Do not disconnect the printer if you want to use it to print error messages.
Collect all tools and utilities, such as a Torx screwdriver, loopback adapters, ESD wrist strap, and software utilities, necessary to troubleshoot the problem. o
You must have the appropriate Health Drivers and Management Agents installed on the server. o o
To verify the server configuration, connect to the System Management homepage and select Version
Control Agent. The VCA gives you a list of names and versions of all installed HP drivers,
Management Agents, and utilities, and whether they are up-to-date.
HP recommends you have access to the server documentation for server-specific information.
HP recommends you have access to the SmartStart CD for value-added software and drivers required during the troubleshooting process. Download the current version of SmartStart from the
HP website ( http://www.hp.com/servers/smartstart ).
Performing processor procedures in the troubleshooting process
Before performing any troubleshooting steps that involve processors, review the following guidelines:
•
Be sure that only authorized personnel perform the troubleshooting steps that involve installing, removing, or replacing a processor.
•
Always locate the documentation for your processor model before performing any steps that require installing, removing, or replacing a processor. If you cannot locate the hard copy of the instructions that shipped with the processor, see the processor instructions in this document.
•
Some processor models require the use of a processor installation tool, and specific steps are documented to ensure that you do not damage the processor or processor socket on the system board.
For server models that have pins inside the processor socket, remember that THE PINS ON THE SYSTEM
BOARD ARE VERY FRAGILE AND EASILY DAMAGED. If you damage the socket, you must replace the system board.
•
Depending on the server model, the contacts may be on the processor or they may be inside the processor socket. Never touch the contacts. THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND
EASILY DAMAGED. If the contacts inside the processor socket are damaged, the system board must be replaced.
•
Always complete all other troubleshooting procedures before removing or replacing a processor.
Breaking the server down to the minimum hardware configuration
During the troubleshooting process, you may be asked to break the server down to the minimum hardware configuration. A minimum configuration consists of only the components needed to boot the server and successfully pass POST.
Troubleshooting 131
When requested to break the server down to the minimum configuration, uninstall the following components, if installed:
•
All additional DIMMs
Leave only the minimum required to boot the server—either one DIMM or a pair of DIMMs. For more information, see the memory guidelines in the server user guide.
•
All additional cooling fans, if applicable
For the minimum fan configuration, see the server user guide.
•
All additional power supplies, if applicable (leave one installed)
•
All hard drives
•
All optical drives (DVD-ROM, CD-ROM, and so forth)
•
All optional mezzanine cards
•
All expansion boards
Before removing the components, be sure to determine the minimum configuration for each component and follow all guidelines in the server user guide.
Always use the recommended minimum configuration above before removing any processors. If you are unable to isolate the issue with the configuration above, you will then remove all but one of the additional processors.
CAUTION: Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process (on page 131 )."
Failure to follow the recommended guidelines can cause damage to the system board, requiring replacement of the system board.
Loose connections
Action:
•
Be sure all power cords are securely connected.
•
Be sure all cables are properly aligned and securely connected for all external and internal components.
•
Remove and check all data and power cables for damage. Be sure no cables have bent pins or damaged connectors.
•
If a fixed cable tray is available for the server, be sure the cords and cables connected to the server are routed correctly through the tray.
•
Be sure each device is properly seated. Avoid bending or flexing circuit boards when reseating components.
•
If a device has latches, be sure they are completely closed and locked.
•
Check any interlock or interconnect LEDs that may indicate a component is not connected properly.
•
If problems continue to occur, remove and reinstall each device, checking the connectors and sockets for bent pins or other damage.
Troubleshooting 132
Service notifications
To view the latest service notifications, refer to the HP website ( http://www.hp.com/go/bizsupport ). Select the appropriate server model, and then click the Troubleshoot a Problem link on the product page.
Server health LEDs
Some servers have an internal health LED and an external health LED, while other servers have a single system health LED. The system health LED provides the same functionality as the two separate internal and external health LEDs. Depending on the model, the internal health LED and external health LED may either appear solid or they may flash. Both conditions represent the same symptom.
For the location of server LEDs and information on their statuses, see the server documentation on the HP website ( http://www.hp.com/support ).
Troubleshooting flowcharts
To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this section,
"Start diagnosis flowchart (on page 133 )," and follow the appropriate diagnostic path. If the other
flowcharts do not provide a troubleshooting solution, follow the diagnostic steps in "General diagnosis
when the problem is not server-specific or is not easily categorized into the other flowcharts.
The available flowcharts include:
•
Start diagnosis flowchart (on page 133 )
•
General diagnosis flowchart (on page 134 )
•
Server power-on problems flowchart (on page 136 )
•
POST problems flowchart (on page 139 )
•
OS boot problems flowchart (on page 141 )
•
Server fault indications flowchart (on page 142 )
Start diagnosis flowchart
Use the following flowchart to start the diagnostic process.
Item
1
See
"General diagnosis flowchart (on page 134 )"
2
3
"Power-on problems flowchart (" Server power-on problems flowchart " on page 136 )"
"POST problems flowchart (on page 139 )"
4
"OS boot problems flowchart (on page 141 )"
5
"Server fault indications flowchart (on page 142 )"
Troubleshooting 133
General diagnosis flowchart
1
2
The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of the problem, or if the other flowcharts do not fix the problem, use the following flowchart.
Item See
"Symptom information (on page 130 )"
"Loose connections (on page 132 )"
3
"Service notifications (on page 133 )"
4
The most recent version of a particular server or option firmware is available on the HP Support website ( http://www.hp.com/support ).
Troubleshooting 134
6
7
Item
5
8
9
10
See
"General memory problems are occurring" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
Server maintenance and service guide, located on the Documentation CD or the HP website ( http://www.hp.com/products/servers/platforms )
•
"Hardware problems" in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see "Troubleshooting
•
Server maintenance and service guide, located on the Documentation
CD or the HP website
( http://www.hp.com/products/servers/platforms )
"Breaking the server down to the minimum hardware configuration (on
page 131 )" or in the HP ProLiant Servers Troubleshooting Guide located on
the Documentation CD or see "Troubleshooting resources (on page 128 )"
•
"Server information you need" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
•
"Operating system information you need" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
"HP contact information (on page 158 )"
Troubleshooting 135
Server power-on problems flowchart
Symptoms:
•
The server does not power on.
•
The system power LED is off or amber.
Troubleshooting 136
•
The external health LED is red or amber.
•
The internal health LED is red or amber.
NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation.
Possible causes:
•
Improperly seated or faulty power supply
•
Loose or faulty power cord
•
Power source problem
•
Power on circuit problem
•
Improperly seated component or interlock problem
•
Faulty internal component
Item See
1
2
3
"Server health LEDs (on page 133 )" and "Component identification (on
"HP Insight Diagnostics (on page 123 )" or in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
"Loose connections (on page 132 )"
4
5
6
7
8
Server maintenance and service guide, located on the Documentation CD, or the HP website ( http://www.hp.com/products/servers/platforms )
"Integrated Management Log (on page 124 )" or in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
"Power source problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see "Troubleshooting resources (on
•
"Power supply problems" in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see "Troubleshooting
•
Server maintenance and service guide, located on the Documentation
CD, or the HP website
( http://www.hp.com/products/servers/platforms )
"System open circuits and short circuits" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
Troubleshooting 137
Troubleshooting 138
POST problems flowchart
Symptoms:
•
Server does not complete POST
NOTE: The server has completed POST when the system attempts to access the boot device.
•
Server completes POST with errors
Possible problems:
•
Improperly seated or faulty internal component
•
Faulty KVM device
•
Faulty video device
Item See
1
2
"Video problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or see "Troubleshooting resources (on
KVM or iLO 2 documentation
3
"POST error messages and beep codes (on page 144 )"
4
"Symptom information (on page 130 )"
5
6
7
"Port 85 and iLO messages" in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see "Troubleshooting resources
"Server health LEDs (on page 133 )" and "Component identification (on
"Loose connections (on page 132 )"
8
9
10
11
12
"General memory problems are occurring" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
Server maintenance and service guide, located on the Documentation CD or the HP website ( http://www.hp.com/products/servers/platforms ).
"Breaking the server down to the minimum hardware configuration (on
page 131 )" or in the HP ProLiant Servers Troubleshooting Guide located on
the Documentation CD or see "Troubleshooting resources (on page 128 )"
•
"Hardware problems" in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see "Troubleshooting
•
Server maintenance and service guide, located on the Documentation
CD or the HP website
( http://www.hp.com/products/servers/platforms )
"HP contact information (on page 158 )"
Troubleshooting 139
Item
13
See
•
"Server information you need" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
•
"Operating system information you need" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
Troubleshooting 140
OS boot problems flowchart
Symptoms:
•
Server does not boot a previously installed operating system
•
Server does not boot SmartStart
Possible causes:
•
Corrupted operating system
•
Hard drive subsystem problem
•
Incorrect boot order setting in RBSU
Item See
1
2
HP ROM-Based Setup Utility User Guide
(
http://www.hp.com/servers/smartstart
)
"POST problems flowchart (on page 139 )"
3
4
5
6
7
8
9
10
•
"Hard drive problems" in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see "Troubleshooting
•
Controller documentation
"HP Insight Diagnostics (on page 123 )" or in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
•
"CD-ROM and DVD drive problems" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
•
Controller documentation
•
"Loose connections (on page 132 )"
"General memory problems are occurring" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
•
"Operating system problems" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
•
"HP contact information (on page 158 )"
"Breaking the server down to the minimum hardware configuration (on
page 131 )" in the HP ProLiant Servers Troubleshooting Guide located on
the Documentation CD or see "Troubleshooting resources (on page 128 )"
•
"Hardware problems" in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see "Troubleshooting
•
Server maintenance and service guide, located on the Documentation
CD or the HP website
( http://www.hp.com/products/servers/platforms )
"General diagnosis flowchart (on page 134 )"
Troubleshooting 141
Server fault indications flowchart
Symptoms:
•
Server boots, but a fault event is reported by Insight Management Agents
•
Server boots, but the internal health LED, external health LED, or component health LED is red or amber
NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation.
Troubleshooting 142
Possible causes:
•
Improperly seated or faulty internal or external component
•
Unsupported component installed
•
Redundancy failure
4
5
2
3
•
System overtemperature condition
Item See
1
6
•
"Integrated Management Log (on page 124 )" or in the HP ProLiant
Servers Troubleshooting Guide located on the Documentation CD or
see "Troubleshooting resources (on page 128 )"
•
"Event list error messages" in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see "Troubleshooting
"Component identification (on page 7 )"
"Server health LEDs (on page 133 )"
System Management Homepage ( https://localhost:2381 )
"Power-on problems flowchart (" Server power-on problems flowchart " on page 136 )"
"HP Insight Diagnostics (on page 123 )" or in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
7
8
•
"Hardware problems" in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see "Troubleshooting
•
Server maintenance and service guide, located on the Documentation
CD or the HP website
( http://www.hp.com/products/servers/platforms )
•
"Smart Array SCSI Diagnosis feature" or in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 128 )"
•
Server maintenance and service guide, located on the Documentation
CD or the HP website
( http://www.hp.com/products/servers/platforms )
•
"HP contact information (on page 158 )"
Troubleshooting 143
POST error messages and beep codes
For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or on the HP website
( http://www.hp.com/support ).
Troubleshooting 144
WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components.
Troubleshooting 145
Battery replacement
If the server no longer automatically displays the correct date and time, you may need to replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:
•
Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
•
Replace only with the spare designated for this product.
To remove the component:
1.
2.
Power down the server (on page 22 ).
Extend or remove the server from the rack (" Extend the server from the rack " on page 24 ).
3.
4.
Remove the access panel (on page 25 ).
Remove the PCI riser cage.
CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all AC power cords before removing or installing the expansion boards.
5.
Remove the battery.
IMPORTANT: Replacing the system board battery resets the system ROM to its default configuration. After replacing the battery, reconfigure the system through RBSU.
To replace the component, reverse the removal procedure.
Battery replacement 146
For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.
Battery replacement 147
Regulatory compliance notices
Regulatory compliance identification numbers
For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product.
Federal Communications Commission notice
Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio
Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and
B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user.
FCC rating label
The FCC rating label on the device shows the classification (A or B) of the equipment. Class B devices have an FCC logo or ID on the label. Class A devices do not have an FCC logo or ID on the label. After you determine the class of the device, refer to the corresponding statement.
Class A equipment
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.
Class B equipment
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
Regulatory compliance notices 148
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio or television technician for help.
Declaration of conformity for products marked with the FCC logo, United States only
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For questions regarding this product, contact us by mail or telephone:
•
Hewlett-Packard Company
P. O. Box 692000, Mail Stop 530113
Houston, Texas 77269-2000
•
1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be recorded or monitored.)
For questions regarding this FCC declaration, contact us by mail or telephone:
•
Hewlett-Packard Company
P. O. Box 692000, Mail Stop 510101
Houston, Texas 77269-2000
•
1281-514-3333
To identify this product, refer to the part, series, or model number found on the product.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment.
Cables
Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
Canadian notice (Avis Canadien)
Class A equipment
Regulatory compliance notices 149
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Class B equipment
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
European Union regulatory notice
Products bearing the CE marking comply with the following EU Directives:
•
Low Voltage Directive 2006/95/EC
•
EMC Directive 2004/108/EC
•
Ecodesign Directive 2009/125/EC, where applicable
CE compliance of this product is valid if powered with the correct CE-marked AC adapter provided by HP.
Compliance with these directives implies conformity to applicable harmonized European standards
(European Norms) that are listed in the EU Declaration of Conformity issued by HP for this product or product family and available (in English only) either within the product documentation or at the following HP website
( http://www.hp.eu/certificates ) (type the product number in the search field).
The compliance is indicated by one of the following conformity markings placed on the product:
For non-telecommunications products and for EU harmonized telecommunications products, such as
Bluetooth® within power class below 10mW.
For EU non-harmonized telecommunications products (If applicable, a 4-digit notified body number is inserted between CE and !).
Please refer to the regulatory label provided on the product.
The point of contact for regulatory matters is Hewlett-Packard GmbH, Dept./MS: HQ-TRE, Herrenberger
Strasse 140, 71034 Boeblingen, GERMANY.
Disposal of waste equipment by users in private households in the European Union
Regulatory compliance notices 150
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
Japanese notice
BSMI notice
Korean notice
Class A equipment
Regulatory compliance notices 151
Class B equipment
Chinese notice
Class A equipment
Vietnam compliance marking notice
This marking is for applicable products only.
Laser compliance
This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC 60825-1. The product does not emit hazardous laser radiation.
Each laser product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser
Notice No. 50, dated June 24, 2007; and with IEC 60825-1:2007.
WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation:
• Do not try to open the module enclosure. There are no user-serviceable components inside.
• Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein.
•
Allow only HP Authorized Service technicians to repair the unit.
The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976. These regulations apply to laser products manufactured from August 1, 1976. Compliance is mandatory for products marketed in the United States.
Battery replacement notice
Regulatory compliance notices 152
WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:
• Do not attempt to recharge the battery.
•
Do not expose the battery to temperatures higher than 60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, use the public collection system or return them to HP, an authorized HP Partner, or their agents.
For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.
Taiwan battery recycling notice
The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the
Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion.
Contact a qualified Taiwanese recycler for proper battery disposal.
Power cord statement for Japan
Acoustics statement for Germany (Geräuschemission)
Schalldruckpegel L pA
< 70 dB(A)
Zuschauerpositionen (bystander positions), Normaler Betrieb (normal operation)
Nach ISO 7779:1999 (Typprüfung)
Regulatory compliance notices 153
Electrostatic discharge
Preventing electrostatic discharge
To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.
To prevent electrostatic damage:
•
Avoid hand contact by transporting and storing products in static-safe containers.
•
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
•
Place parts on a grounded surface before removing them from their containers.
•
Avoid touching pins, leads, or circuitry.
•
Always be properly grounded when touching a static-sensitive component or assembly.
Grounding methods to prevent electrostatic discharge
Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts:
•
Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.
•
Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.
•
Use conductive field service tools.
•
Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part.
For more information on static electricity or assistance with product installation, contact an authorized reseller.
Electrostatic discharge 154
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature 28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 kPa.
Server specifications
Specification Value
Dimensions
Rack model
—
Height
Depth
Width
Tower model
Height
Depth
Width
17.48 cm (6.88 in)
69.93 cm (27.53 in)
48.34 cm (19.03 in)
—
47.04 cm (18.52 in)
73.96 cm (29.12 in)
24.77 cm (9.75 in)
Weight
Weight (when lightly loaded) —
Rack
25.00 kg (55.12 lbs)
Tower
30.00 kg (66.14 lbs)
Weight (maximum)
46.75 kg (103.06 lbs)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
Specifications 155
•
HP ProLiant 1200 W Power Supply
Specification Value
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
100 to 120 VAC, 200 to
240 VAC
50 Hz to 60 Hz
10 A at 100 VAC
4.9 A at 200 VAC
930 W at 100V AC input
1348 W at 200V AC input
3530 at 120V AC input
4600 at 200V to 240V AC input
Power supply output
Rated steady-state power
Maximum peak power
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC input
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC input
•
HP ProLiant 750 W Power Supply
Specification Value
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
100 to 120 VAC, 200 to
240 VAC
50 Hz to 60 Hz
8.9 A at 100 VAC
4.3 A at 200 VAC
857 W at 100V AC input
824 W at 200V AC input
2925 at 100V AC input
2812 at 200V AC input
Power supply output
Rated steady-state power
Maximum peak power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
•
HP ProLiant 460 W Power Supply
Specification Value
Input requirements
Rated input voltage
Rated input frequency
100 to 120 VAC, 200 to
240 VAC
50 Hz to 60 Hz
Specifications 156
Rated input current
Rated input power
BTUs per hour
Power supply output
Rated steady-state power
Maximum peak power
5.5 A at 100 VAC
2.6 A at 200 VAC
526 W at 100V AC input
505 W at 200V AC input
1794 at 100V AC input
1725 at 200V AC input
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
Specifications 157
Technical support
Before you contact HP
Be sure to have the following information available before you call HP:
•
Technical support registration number (if applicable)
•
Product serial number
•
Product model name and number
•
Product identification number
•
Applicable error messages
•
Add-on boards or hardware
•
Third-party hardware or software
•
Operating system type and revision level
HP contact information
For the name of the nearest HP authorized reseller:
•
See the Contact HP worldwide (in English) webpage
( http://welcome.hp.com/country/us/en/wwcontact.html
).
For HP technical support:
•
In the United States, for contact options see the Contact HP United States webpage
( http://welcome.hp.com/country/us/en/contact_us.html
). To contact HP by phone: o
Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored. o
If you have purchased a Care Pack (service upgrade), call 1-800-633-3600. For more information about Care Packs, refer to the HP website ( http://www.hp.com/hps ).
•
In other locations, see the Contact HP worldwide (in English) webpage
( http://welcome.hp.com/country/us/en/wwcontact.html
).
Customer Self Repair
HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts:
•
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.
Technical support 158
•
Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.
NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty,
HP requires that an authorized service provider replace the part. These parts are identified as "No" in the
Illustrated Parts Catalog.
Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits.
If assistance is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days. The defective part must be returned with the associated documentation in the provided shipping material. Failure to return the defective part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping and part return costs and determine the courier/carrier to be used.
For more information about HP's Customer Self Repair program, contact your local service provider. For the
North American program, refer to the HP website ( http://www.hp.com/go/selfrepair ).
Réparation par le client (CSR)
Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client) afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut être effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement. Il existe deux catégories de pièces CSR:
Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.
Facultatif - Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.
REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le Catalogue illustré.
Les pièces CSR sont livrées le jour ouvré suivant, dans la limite des stocks disponibles et selon votre situation géographique. Si votre situation géographique le permet et que vous demandez une livraison le jour même ou dans les 4 heures, celle-ci vous sera facturée. Pour bénéficier d'une assistance téléphonique, appelez le
Centre d'assistance technique HP. Dans les documents envoyés avec la pièce de rechange CSR, HP précise s'il est nécessaire de lui retourner la pièce défectueuse. Si c'est le cas, vous devez le faire dans le délai indiqué, généralement cinq (5) jours ouvrés. La pièce et sa documentation doivent être retournées dans l'emballage fourni. Si vous ne retournez pas la pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais d'expédition et de retour, et détermine la société de courses ou le transporteur à utiliser.
Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations sur ce programme en Amérique du Nord, consultez le site Web HP
( http://www.hp.com/go/selfrepair ).
Technical support 159
Riparazione da parte del cliente
Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di assistenza
HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sostituzione. Vi sono due categorie di parti CSR:
Obbligatorie – Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.
Opzionali – Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.
NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un "No" nel Catalogo illustrato dei componenti.
In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro il giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore è offerta con un supplemento di costo solo in alcune zone. In caso di necessità si può richiedere l'assistenza telefonica di un addetto del centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR, HP specifica se il cliente deve restituire dei componenti. Qualora sia richiesta la resa ad HP del componente difettoso, lo si deve spedire ad HP entro un determinato periodo di tempo, generalmente cinque (5) giorni lavorativi. Il componente difettoso deve essere restituito con la documentazione associata nell'imballo di spedizione fornito. La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di HP.
Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare.
Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il programma in Nord America fare riferimento al sito Web HP ( http://www.hp.com/go/selfrepair ).
Customer Self Repair
HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere
Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP Servicepartner) bei der
Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden kann, sendet Ihnen HP dieses
Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien unterteilt:
Zwingend – Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den
Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen
Service berechnet.
Optional – Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer
Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche
Kosten anfallen.
HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des
Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
Technical support 160
CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert.
Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen
Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert werden, können Sie entnehmen, ob das defekte Teil an HP zurückgeschickt werden muss. Wenn es erforderlich ist, das defekte Teil an HP zurückzuschicken, müssen Sie dies innerhalb eines vorgegebenen
Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen. Das defekte Teil muss mit der zugehörigen
Dokumentation in der Verpackung zurückgeschickt werden, die im Lieferumfang enthalten ist. Wenn Sie das defekte Teil nicht zurückschicken, kann HP Ihnen das Ersatzteil in Rechnung stellen. Im Falle von Customer
Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den
Kurier-/Frachtdienst.
Weitere Informationen über das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner vor Ort. Informationen über das CSR-Programm in Nordamerika finden Sie auf der HP Website unter
( http://www.hp.com/go/selfrepair ).
Reparaciones del propio cliente
Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer Self
Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de realizar sustituciones de componentes defectuosos. Si, durante la fase de diagnóstico, HP (o los proveedores o socios de servicio de HP) identifica que una reparación puede llevarse a cabo mediante el uso de un componente
CSR, HP le enviará dicho componente directamente para que realice su sustitución. Los componentes CSR se clasifican en dos categorías:
•
Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a
HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.
•
Opcional: componentes para los que la reparación por parte del usuario es opcional. Estos componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al producto.
NOTA: Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra "No" en el catálogo ilustrado de componentes.
Según la disponibilidad y la situación geográfica, los componentes CSR se enviarán para que lleguen a su destino al siguiente día laborable. Si la situación geográfica lo permite, se puede solicitar la entrega en el mismo día o en cuatro horas con un coste adicional. Si precisa asistencia técnica, puede llamar al Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales para la sustitución de componentes CSR, HP especificará si los componentes defectuosos deberán devolverse a HP. En aquellos casos en los que sea necesario devolver algún componente a HP, deberá hacerlo en el periodo de tiempo especificado, normalmente cinco días laborables. Los componentes defectuosos deberán devolverse con toda la documentación relacionada y con el embalaje de envío. Si no enviara el componente defectuoso requerido, HP podrá cobrarle por el de sustitución. En el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio.
Technical support 161
Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedor de servicios local. Si está interesado en el programa para Norteamérica, visite la página web de HP siguiente ( http://www.hp.com/go/selfrepair ).
Customer Self Repair
Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt HP dat onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee kunt vervangen. Er zijn twee categorieën CSR-onderdelen:
Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening gebracht.
Optioneel: Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.
OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen.
Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".
Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op de eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een HP Service
Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de documentatie bij het vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden geretourneerd. Als het defecte onderdeel aan HP moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal. Als u het defecte onderdeel niet terugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen. Bij reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde onderdeel en kiest HP zelf welke koerier/transportonderneming hiervoor wordt gebruikt.
Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website ( http://www.hp.com/go/selfrepair ).
Reparo feito pelo cliente
Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se, durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o reparo pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao cliente.
Existem duas categorias de peças CSR:
Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
Technical support 162
Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.
OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca "No" (Não), no catálogo de peças ilustrado.
Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional. Se precisar de auxílio, entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone. A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP dentro do período determinado, normalmente cinco (5) dias úteis.
A peça com defeito deve ser enviada com a documentação correspondente no material de transporte fornecido. Caso não o faça, a HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a
HP paga todas as despesas de transporte e de devolução da peça e determina a transportadora/serviço postal a ser utilizado.
Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP
( http://www.hp.com/go/selfrepair ).
Technical support 163
Technical support 164
Technical support 165
Acronyms and abbreviations
ABEND abnormal end
ACU
Array Configuration Utility
AMP
Advanced Memory Protection
ASR
Automatic Server Recovery
BBWC battery-backed write cache
CSA
Canadian Standards Association
CSR
Customer Self Repair
DDR double data rate
ECC error checking and correcting
FBWC flash-backed write cache
IEC
International Electrotechnical Commission iLO
Integrated Lights-Out
Acronyms and abbreviations 166
IML
Integrated Management Log
NMI non-maskable interrupt
NVRAM non-volatile memory
ORCA
Option ROM Configuration for Arrays
PCIe peripheral component interconnect express
POST
Power-On Self Test
PPM processor power module
PSP
ProLiant Support Pack
RBSU
ROM-Based Setup Utility
RDIMM
Registered Dual In-line Memory Module
RDP
Rapid Deployment Pack
SAS serial attached SCSI
SFF small form-factor
SIM
Systems Insight Manager
Acronyms and abbreviations 167
TMRA recommended ambient operating temperature
UDIMM
Unregistered Dual In-Line Memory Module
UID unit identification
UPS uninterruptible power system
USB universal serial bus
VCA
Version Control Agent
Acronyms and abbreviations 168
Index
A
acoustics statement for Germany 153
ACU (Array Configuration Utility) 119
Advanced ECC memory 49, 50, 118, 119
AMP (Advanced Memory Protection) 118
Array Configuration Utility (ACU) 119
auto-configuration process 117
B
battery-backed write cache (BBWC) 19, 27, 84, 85,
battery-backed write cache battery pack 27, 84, 85,
86 battery-backed write cache procedures 84, 85, 86
BBWC (battery-backed write cache) 19, 27, 84, 85,
BBWC battery pack 27, 84, 85, 86
C
cabling 103, 105, 106, 107, 108, 109, 110, 111,
cautions 129 cautions, electrical 129 cautions, power cord 129 cautions, ventilation 129
change control and proactive notification 127
configuration of system 40, 116
configuring AMP modes 118, 119
D
data cabling 103, 104, 105, 106, 107, 108, 109,
diagnostic tools 121, 123 diagnostics utility 123
DIMM installation guidelines 50
drive cage, installing 59, 61, 69
E
Eight-bay SFF drive cage 59, 61, 107
electrical grounding requirements 35
environmental requirements 34, 155
Index 169
F
FCC (Federal Communications Commission)
Federal Communications Commission (FCC)
firmware upgrade utility, troubleshooting 128
flash-backed write cache capacitor pack 27, 84, 85,
86 flash-backed write cache module 84, 85, 86 flash-backed write cache procedures 84, 85, 86
flowcharts 133, 134, 136, 139, 141, 142
G
general diagnosis flowchart 134
H
hard drive cabling 103, 104, 105, 106, 107, 108
hard drive drawer, removing 58
hard drive LEDs 17 hard drives, determining status of 17
hard drives, installing 41, 57
hardware options 41 hardware options installation 38, 41
HP Insight Diagnostics survey functionality 123
HP Insight Remote Support software 124
HP NC524SFP Dual Port 10GbE Module 80
HP ProLiant Essentials Foundation Pack 40
HP Smart Update Manager overview 126
I
iLO (Integrated Lights-Out) 121
IML (Integrated Management Log) 124
Important Safety Information document 128
installing operating system 40
J
K
L
M
media device data cabling 109, 110
memory subsystem architecture 47
memory, configuration requirements 48, 50
memory, configuring 48, 49, 119 memory, lockstep 49, 50, 51, 119
minimum hardware configuration 131
multi-processor Advanced ECC population order 50
multi-processor Lockstep population order 51
Index 170
N
O
online spare memory 49, 51, 118
Option ROM Configuration for Arrays (ORCA) 120
ORCA (Option ROM Configuration for Arrays) 120
OS boot problems flowchart 141
P
PCI expansion slots 11, 13, 22
power distribution unit (PDU) 35
power supply backplane connector 21
power supply specifications 155
preparation procedures 22, 130
R
RBSU (ROM-Based Setup Utility) 116, 118
regulatory compliance notices 148, 150
remote support and analysis tools 124
removable media devices 73, 74
ROM-Based Setup Utility (RBSU) 101, 116
S
server fault indications flowchart 142
server features and options 41
server power-on problems flowchart 136
server warnings and cautions 36
single-processor Advanced ECC population order 50
single-processor Lockstep population order 51
six-bay LFF backplane 64, 65, 67, 106
SmartStart Scripting Toolkit 116
Index 171
system configuration settings 40, 116
system maintenance switch 13, 14, 15
Systems Insight Display connector 13
Systems Insight Display LEDs 9
T
Taiwan battery recycling notice 153
technical support 158 telephone numbers 158
TPM (Trusted Platform Module) 13, 99, 100, 101
troubleshooting flowcharts 133
troubleshooting, firmware upgrade utility 128
Trusted Platform Module (TPM) 99, 100, 101
U
UPS (uninterruptible power supply) 35
V
Vietnam compliance marking notice 152
W
Index 172
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 HP ProLiant DL/ML370 G6 Server User Guide
- 1 Abstract
- 2 Notice
- 3 Contents
- 7 Component identification
- 7 Front panel components
- 8 Front panel LEDs and buttons
- 9 Systems Insight Display LEDs
- 9 Systems Insight Display LED combinations
- 11 Rear panel components
- 12 Rear panel LEDs
- 13 System board components
- 14 DIMM slots
- 14 System maintenance switch
- 15 NMI functionality
- 16 SAS and SATA device numbers
- 17 SAS and SATA hard drive LEDs
- 17 SAS and SATA hard drive LED combinations
- 18 Fans
- 19 Battery pack LEDs
- 20 FBWC module LEDs
- 21 Power supply backplane connectors
- 21 Drive cage jumper configuration settings
- 22 Operations
- 22 Power up the server
- 22 Power down the server
- 22 Open or remove the tower bezel
- 24 Extend the server from the rack
- 25 Remove the access panel
- 26 Remove fans 1-4
- 26 Remove fan 5
- 27 Remove the BBWC battery pack or the FBWC capacitor pack
- 28 Remove the air baffle
- 29 Remove the fan cage
- 30 Remove the media bay blank
- 31 Remove the DVD-ROM drive
- 31 Remove the hard drive cage blank
- 33 Setup
- 33 Optional installation services
- 33 Rack planning resources
- 34 Optimum environment
- 34 Space and airflow requirements
- 35 Temperature requirements
- 35 Power requirements
- 35 Electrical grounding requirements
- 36 Rack warnings
- 36 Server warnings and cautions
- 37 Identifying tower server shipping carton contents
- 37 Identifying rack server shipping carton contents
- 38 Installing hardware options
- 38 Setting up a tower server
- 39 Installing the server into the rack
- 40 Powering up and configuring the server
- 40 Installing the operating system
- 40 Registering the server
- 41 Hardware options installation
- 41 Introduction
- 41 Processor option
- 46 Memory options
- 47 Memory subsystem architecture
- 47 Single-, dual-, and quad-rank DIMMs
- 47 DIMM identification
- 48 Memory configurations
- 49 RDIMM maximum memory configurations
- 49 UDIMM maximum memory configurations
- 49 Advanced ECC memory configuration
- 49 Lockstep memory configuration
- 49 Online Spare memory configuration
- 50 General DIMM slot population guidelines
- 50 Advanced ECC population guidelines
- 50 Multi-processor Advanced ECC population order
- 50 Single-processor Advanced ECC population order
- 50 Lockstep Memory population guidelines
- 51 Single-processor Lockstep population order
- 51 Multi-processor Lockstep population order
- 51 Online Spare population guidelines
- 52 Installing a DIMM
- 53 Redundant fans option
- 53 Redundant fan guidelines
- 53 Installing redundant fans
- 55 Redundant hot-plug power supply option
- 55 Power supply configuration
- 55 Hot-plug power supply calculations
- 56 Installing a redundant hot-plug power supply
- 57 Hot-plug SAS hard drive options
- 57 Installing a hot-plug SAS hard drive
- 58 Removing a hot-plug SAS hard drive
- 59 Eight-bay SFF drive cage option
- 59 Installing the eight-bay SFF drive cage (bay 2)
- 61 Installing the eight-bay SFF drive cage (bay 3)
- 64 Six-bay LFF backplane option
- 65 Installing the six-bay LFF backplane (bay 1)
- 67 Installing the six-bay LFF backplane (bay 2)
- 69 Two-bay LFF drive cage option
- 73 Removable media device options
- 73 Installing a half-height media device
- 74 Installing a full-height media device
- 76 Slimline optical drive option
- 78 Expansion board options
- 80 HP NC524SFP Dual Port 10GbE Module option
- 84 Storage controller option
- 84 BBWC and FBWC options
- 85 Installing the cache module
- 86 Installing the BBWC battery pack or the FBWC capacitor pack
- 87 HP SAS Expander Card option
- 88 Graphics adapter option
- 89 Tower-to-rack conversion kit option
- 99 HP Trusted Platform Module option
- 100 Installing the Trusted Platform Module board
- 101 Retaining the recovery key/password
- 101 Enabling the Trusted Platform Module
- 103 Cabling
- 103 Storage device cabling guidelines
- 103 Data cabling
- 103 Server data cabling
- 104 SAS hard drive cabling
- 105 Two-bay LFF drive cage cabling
- 106 Six-bay LFF backplane cabling
- 107 Eight-bay SFF drive cage cabling
- 108 SAS expander cabling
- 109 Media device data cabling
- 110 DVD-ROM drive cabling
- 110 Slimline optical drive cabling
- 111 Power cabling
- 111 Server power cabling (basic configuration)
- 112 Server power cabling (maximum configuration)
- 113 Hard drive cage power cabling
- 114 Front panel cabling
- 115 BBWC battery pack and FBWC capacitor pack cabling
- 116 Software and configuration utilities
- 116 Configuration tools
- 116 SmartStart software
- 116 SmartStart Scripting Toolkit
- 116 HP ROM-Based Setup Utility
- 117 Using RBSU
- 117 Auto-configuration process
- 118 Boot options
- 118 BIOS Serial Console
- 118 Configuring AMP modes
- 118 Configuring mirrored memory
- 119 Configuring Advanced ECC memory
- 119 Configuring lockstep memory
- 119 Array Configuration Utility
- 120 Option ROM Configuration for Arrays
- 120 Re-entering the server serial number and product ID
- 121 Management tools
- 121 Automatic Server Recovery
- 121 ROMPaq utility
- 121 Integrated Lights-Out 2 technology
- 122 Erase Utility
- 122 Redundant ROM support
- 122 Safety and security benefits
- 123 USB support
- 123 Diagnostic tools
- 123 HP Insight Diagnostics
- 123 HP Insight Diagnostics survey functionality
- 124 Integrated Management Log
- 124 Remote support and analysis tools
- 124 HP Insight Remote Support software
- 125 Keeping the system current
- 125 Drivers
- 125 Version control
- 125 ProLiant Support Packs
- 126 Operating System Version Support
- 126 Firmware
- 126 HP Smart Update Manager
- 127 Change control and proactive notification
- 127 Care Pack
- 128 Troubleshooting
- 128 Troubleshooting resources
- 128 Pre-diagnostic steps
- 128 Important safety information
- 129 Symbols on equipment
- 129 Warnings and cautions
- 130 Symptom information
- 130 Prepare the server for diagnosis
- 131 Performing processor procedures in the troubleshooting process
- 131 Breaking the server down to the minimum hardware configuration
- 132 Loose connections
- 133 Service notifications
- 133 Server health LEDs
- 133 Troubleshooting flowcharts
- 133 Start diagnosis flowchart
- 134 General diagnosis flowchart
- 136 Server power-on problems flowchart
- 139 POST problems flowchart
- 141 OS boot problems flowchart
- 142 Server fault indications flowchart
- 144 POST error messages and beep codes
- 146 Battery replacement
- 148 Regulatory compliance notices
- 148 Regulatory compliance identification numbers
- 148 Federal Communications Commission notice
- 148 FCC rating label
- 148 Class A equipment
- 148 Class B equipment
- 149 Declaration of conformity for products marked with the FCC logo, United States only
- 149 Modifications
- 149 Cables
- 149 Canadian notice (Avis Canadien)
- 150 European Union regulatory notice
- 150 Disposal of waste equipment by users in private households in the European Union
- 151 Japanese notice
- 151 BSMI notice
- 151 Korean notice
- 152 Chinese notice
- 152 Vietnam compliance marking notice
- 152 Laser compliance
- 152 Battery replacement notice
- 153 Taiwan battery recycling notice
- 153 Power cord statement for Japan
- 153 Acoustics statement for Germany (Geräuschemission)
- 154 Electrostatic discharge
- 154 Preventing electrostatic discharge
- 154 Grounding methods to prevent electrostatic discharge
- 155 Specifications
- 155 Environmental specifications
- 155 Server specifications
- 155 Power supply specifications
- 158 Technical support
- 158 Before you contact HP
- 158 HP contact information
- 158 Customer Self Repair
- 166 Acronyms and abbreviations
- 169 Index