advertisement
▼
Scroll to page 2
of
92
Invacare® 9000 Series Wheelchair 9000 SL 9000 XT 9000 XDT 9000XT Recliner This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference. User Manual EN © 2013 Invacare Corporation. All rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. 3-in-1 oil is a registered trademark of American Home Products Corporation. Teflon is a registered trademark of E.I. Du Pont De Nemours and Company. Invacare® 9000 Series Wheelchair 2 Part No. 1056953 CONTENTS 1 GENERAL ...............................................................................................................................................................................................6 2 Symbols .................................................................................................................................................................................................................................................... 6 Limited Warranty .................................................................................................................................................................................................................................. 7 OVERVIEW ............................................................................................................................................................................................8 3 Label Locations....................................................................................................................................................................................................................................... 8 Typical Product Parameters .............................................................................................................................................................................................................. 10 SAFETY ................................................................................................................................................................................................15 4 General Guidelines .............................................................................................................................................................................................................................. 15 Operating Information........................................................................................................................................................................................................................ 16 Safety/Handling of Wheelchairs........................................................................................................................................................................................................ 24 SAFETY INSPECTION/TROUBLESHOOTING .............................................................................................................................32 5 Safety Inspection Checklist ................................................................................................................................................................................................................ 32 Troubleshooting................................................................................................................................................................................................................................... 35 Maintenance .......................................................................................................................................................................................................................................... 36 FRONT RIGGINGS .............................................................................................................................................................................39 Installing/Removing Front Riggings................................................................................................................................................................................................... 39 Adjusting Footplate Height ................................................................................................................................................................................................................ 41 Raising/Lowering Elevating Legrest Assembly ............................................................................................................................................................................... 43 Installing Impact Guards/Calf Strap.................................................................................................................................................................................................. 44 Replacing Heel Loop ........................................................................................................................................................................................................................... 44 Part No. 1056953 3 Invacare® 9000 Series Wheelchair CONTENTS 6 ARMS ....................................................................................................................................................................................................46 7 Adjusting Armrest Height .................................................................................................................................................................................................................. 46 Using Swing-Back Arms...................................................................................................................................................................................................................... 47 Removing or Replacing Armrest ...................................................................................................................................................................................................... 48 Replacing Desk/Full Length Armrest Pad (Fixed Height Arms Only)...................................................................................................................................... 49 Replacing Clothing Guards (Fixed Height Arms Only) ............................................................................................................................................................... 49 Converting Between Space Saver and Conventional Arms ....................................................................................................................................................... 49 SEAT AND BACK ...............................................................................................................................................................................51 8 Replacing Seat Upholstery ................................................................................................................................................................................................................. 51 Replacing Back Upholstery ................................................................................................................................................................................................................ 52 Adjusting Back Height, Back Angle or Seat Depth....................................................................................................................................................................... 54 Adjusting Seat Width .......................................................................................................................................................................................................................... 54 REAR WHEELS ...................................................................................................................................................................................55 9 Removing/Installing Rear Wheels..................................................................................................................................................................................................... 55 Replacing Rear Wheel Handrim ....................................................................................................................................................................................................... 57 Adjusting Quick-Release Axle........................................................................................................................................................................................................... 58 FRONT CASTERS ...............................................................................................................................................................................60 Installing/Replacing Six or Eight-Inch Front Casters and Forks................................................................................................................................................. 60 Adjusting Front Caster Mounting..................................................................................................................................................................................................... 61 10 ANTI-TIPPERS/WHEEL LOCKS ......................................................................................................................................................62 Installing/Adjusting Anti-tippers........................................................................................................................................................................................................ 62 Using/Adjusting Patient Operated Wheel Locks.......................................................................................................................................................................... 65 Installing Wheel Lock Shoe Extensions .......................................................................................................................................................................................... 69 Invacare® 9000 Series Wheelchair 4 Part No. 1056953 11 RECLINER ............................................................................................................................................................................................70 Operating Recliner .............................................................................................................................................................................................................................. 70 Replacing Headrest Pillow ................................................................................................................................................................................................................. 72 Replacing Headrest/Back Upholstery .............................................................................................................................................................................................. 73 Adjusting Headrest/Back Upholstery Tension .............................................................................................................................................................................. 74 Adjusting Seat Depth .......................................................................................................................................................................................................................... 74 Adjusting Seat Width .......................................................................................................................................................................................................................... 74 Storing/Replacing Spreader Bar ........................................................................................................................................................................................................ 75 Installing Anti-Tippers ......................................................................................................................................................................................................................... 76 Removing/Installing Rear Wheels..................................................................................................................................................................................................... 77 Using/Adjusting Wheel Locks ........................................................................................................................................................................................................... 78 Installing Telescoping I.V. Rod........................................................................................................................................................................................................... 81 12 OPTIONS .............................................................................................................................................................................................83 Installing/Cleaning Telescoping I.V. Rod/O2 Holders.................................................................................................................................................................. 83 Installing Crutch and Cane Carrier.................................................................................................................................................................................................. 85 Installing Amputee Bracket................................................................................................................................................................................................................ 86 Installing the Wheel Lock Extension Handle................................................................................................................................................................................. 91 Part No. 1056953 5 Invacare® 9000 Series Wheelchair 1 GENERAL 1 General 1.1 Symbols Warnings Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. See the information below for definitions of the signal words. DANGER WARNING CAUTION ! Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, may result in property damage or minor injury or both. IMPORTANT Indicates a hazardous situation that could result in damage to property if it is not avoided. Gives useful tips, recommendations and information for efficient, trouble-free use. Invacare® 9000 Series Wheelchair 6 Part No. 1056953 1 GENERAL 1.2 Limited Warranty PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the original purchaser who purchases this product when new and unused from Invacare or a dealer. This warranty is not extended to any other person or entity and is not transferable or assignable to any subsequent purchaser or owner. Coverage under this warranty will end upon any such subsequent sale or other transfer of title to any other person. This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state. Invacare warrants the side frames and cross members of this product when purchased new and unused to be free from defects in materials and workmanship for a period of five (5) years from the date of purchase from Invacare or a dealer, with a copy of the seller’s invoice required for coverage under this warranty. Invacare warrants the upholstered materials (seat, back and armrests of the arm assembly) and remaining components of this product when purchased new and unused to be free from defects in materials and workmanship for a period of thirteen (13) months from date of purchase from Invacare or a dealer, with a copy of the seller’s invoice required for coverage under this warranty. If within such warranty periods any such product shall be proven to be defective, such product shall be repaired or replaced, at Invacare’s option. This warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product. Invacare’s sole obligation and your exclusive remedy under this warranty shall be limited to such repair and/or replacement. For warranty service, please contact the dealer from whom you purchased your Invacare product. In the event you do not receive satisfactory warranty service, please write directly to Invacare at the address at the bottom of this page. Provide dealer’s name, address, the product model number, date of purchase, indicate nature of the defect and, if the product is serialized, indicate the serial number. Do not return products to our factory without our prior consent. LIMITATIONS AND EXCLUSIONS: THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED, PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR STORAGE, PRODUCTS MODIFIED WITHOUT INVACARE’S EXPRESS WRITTEN CONSENT INCLUDING, BUT NOT LIMITED TO, MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS; PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE, OR TO A PRODUCT DAMAGED BY CIRCUMSTANCES BEYOND INVACARE’S CONTROL, AND SUCH EVALUATION WILL BE SOLELY DETERMINED BY INVACARE. THE WARRANTY SHALL NOT APPLY TO NORMAL WEAR AND TEAR OR FAILURE TO ADHERE TO THE PRODUCT INSTRUCTIONS. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER, SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN. THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN. INVACARE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE, OR LIMITATION OF HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE EXCLUSION AND LIMITATION MAY NOT BE APPLICABLE. THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/PROVINCIAL LAWS AND REQUIREMENTS. Part No. 1056953 7 Invacare® 9000 Series Wheelchair 2 OVERVIEW 2 Overview 2.1 Label Locations Crossmember Serial Number Label is located on the cross brace on the left side of the chair Lower Frame Tube 9000 XDT Only Invacare® 9000 Series Wheelchair 8 Part No. 1056953 2 OVERVIEW NOTE: On all adjustable anti-tippers 9000 XT Recliner Models Only ! WARNING Refer to the Owner’s Manual for proper anti-tipper setting. ! AVERTISSEMENT WARNING Se référer au manuel de l’utilisateur pour le réglage adéquat de l’antibascule. DO NOT OPERATE WITHOUT THE ANTI-TIP TUBES INSTALLED. P/N 60106X144 REV. 5/98 No. 1091554 ! WARNING Do not operate without the antitip tubes installed. ! AVERTISSEMENT NE PAS utiliser sans d’abord avoir installé les antibascules. No. 1091552 CAUTION Models with Quick-Release Axles Only DO NOT recline without occupant. When the chair is not occupied the back will raise abruptly. Keep clear of the chair back when raising or lowering to avoid injury. 1023096 WA R N I N G CAUTION DETENT BALLS MUST BE SECURELY SEATED IN RECESSED AREAS OF AXLE BUSHINGS. ENSURE THAT PLUNGER PIN IN HEAD END OF AXLE IS FULLY RELEASED. KEEP DETENT BALLS CLEAN. SERVICE OF SPRING LIFT MECHANISM TO BE PERFORMED BY PROPERLY TRAINED AUTHORIZED SERVICE PERSONNEL ONLY. 1022642 1001948 Part No. 1056953 9 Invacare® 9000 Series Wheelchair 2 OVERVIEW 2.2 Typical Product Parameters 9000 SL OVERALL WIDTH 23 or 25 inches REAR AXLE Permanent* and quick-release OVERALL DEPTH 43½ inches (WITH RIGGINGS) HANDRIMS Composite* and aluminum, steel SEAT WIDTH 16, 18 or 20 inches WHEEL LOCKS Toggle lock -push or pull SEAT DEPTH 16 or 18 inches CASTER SIZE 6 x 1-inch Urethane, 8 x 1¼-inch* Urethane, 8x1-inch solid rubber, and 8x1¼-inch pneumatic or pneumatic flat-free insert SEAT-TO-FLOOR TALL/ADULT: ADULT/HEMI: SUPER HEMI: UPHOLSTERY Black nylon*, black vinyl N/A 15½ to 19½ in 1-inch increments N/A BACK STYLE Sectional* - 1 inch increments; Adjustable angle - 85° to 110° in 5° increments WEIGHT 33½ lbs (18 x 16 seat) BACK HEIGHT 15 to 19 inches in 1-inch increments WEIGHT LIMIT 250 lbs (114 kg) ARM STYLES Swing Back* Space Saver*, Desk* or full length in Fixed* or Adjustable Height Swing Back Removable, Conventional, Adjustable Height (Adjustable back angle style) SHIPPING WEIGHT (APPROX.) 43 lbs (16x16 inch seat frame with complete pkg) FRONT RIGGINGS Swingaway footrests and elevating legrests REAR WHEELS 20, 22 and 24*-inch composite; Urethane*, pneumatic or pneumatic-flat free insert Invacare® 9000 Series Wheelchair 10 Part No. 1056953 2 OVERVIEW 9000 XT OVERALL WIDTH 21, 22, 23, 25, 27 or 29 inches CASTER SIZE 6 x 1-inch Urethane, 8 x 1¼-inch* Urethane, 8x1-inch solid rubber, and 8x1¼-inch pneumatic or pneumatic flat-free insert, 8x1¾-inch semi pneumatic OVERALL DEPTH (WITH RIGGINGS) 43½ inches HANDRIMS Composite*, aluminum, steel and plastic coated SEAT WIDTH 14, 15, 16, 18, 20 or 22 inches REAR WHEELS 20, 22 and 24*-inch composite; Urethane*, pneumatic or pneumatic-flat free insert SEAT DEPTH 16, 17, or 18 inches REAR AXLE Permanent* and quick-release SEAT-TO-FLOOR TALL/ADULT: ADULT/HEMI: SUPER HEMI: UPHOLSTERY Black nylon*, black sail cloth, heavy vinyl N/A 15½ to 19½ in 1-inch increments 13½ and 14½ inches BACK STYLE Adjustable* - 1-inch increments Adjustable angle - 85° to 110° in 5° increments SHIPPING WEIGHT (APPROX.) 41½ lbs (16 x 16 inch seat frame with complete package) BACK HEIGHT 15 to 19 inches in 1-inch increments WEIGHT 31 lbs (18 x 16 inch seat) ARM STYLES Swing back removable, space saver* or conventional in desk* or full length and in fixed* or adjustable height WEIGHT LIMIT 250 lbs (114 kg) FRONT RIGGINGS Swingaway footrests/elevating legrests WHEEL LOCKS Toggle lock -push or pull Part No. 1056953 11 Invacare® 9000 Series Wheelchair 2 OVERVIEW 9000 XT RECLINER OVERALL WIDTH 23, 25, 27, 28, 29 or 31 inches REAR WHEELS 20, 22 and 24*-inch composite*; Urethane*, pneumatic or pneumatic-flat free insert OVERALL DEPTH (WITH RIGGINGS) 46 inches REAR AXLE Permanent SEAT WIDTH 14, 16, 18, 19, 20 or 22 inches CASTER SIZE 8 x 1¼-inch* Urethane, 8x1-inch solid rubber, and 8x1¼-inch pneumatic or pneumatic flat-free insert, 8x1¾-inch semi pneumatic SEAT DEPTH 16, 17, or 18 inches HANDRIMS Composite*, aluminum, steel and plastic coated UPHOLSTERY Heavy vinyl, light vinyl, nylon, sail cloth SEAT-TO-FLOOR** TALL/ADULT: ADULT/HEMI: SUPER HEMI: 17½-19½ inches - 1inch increments N/A N/A BACK STYLE Reclining WEIGHT LIMIT 250 lbs (114 kg) BACK HEIGHT 23 or 24 inches WEIGHT 50½ lbs ARM STYLES Conventional Desk* or full length and in fixed* or adjustable height SHIPPING WEIGHT (APPROX.) 60½ lbs 18x17-inch seat frame with complete package FRONT RIGGINGS Swingaway footrests and elevating legrests WHEEL LOCKS Toggle lock - push or pull Invacare® 9000 Series Wheelchair 12 Part No. 1056953 2 OVERVIEW 9000 XDT OVERALL WIDTH 23, 25, 27 or 29 inches FRONT RIGGINGS Swingaway and Elevating Footrest OVERALL DEPTH (WITH RIGGINGS) 45½ inches WHEEL LOCKS Toggle lock - push or pull SEAT WIDTH 16, 18, 20 or 22 inches CASTER SIZE 8 x 1¼-inch* Urethane, 8x1-inch solid rubber, and 8x1¼-inch pneumatic or pneumatic flat-free insert, 8x1¾-inch semi pneumatic SEAT DEPTH 16, 17, 18, 19 and 20 inches REAR WHEELS 24*-inch composite, urethane*, pneumatic or pneumatic-flat free insert SEAT-TO-FLOOR** TALL/ADULT: ADULT/HEMI: SUPER HEMI: REAR AXLE Permanent 17½, 19½ and 21½ inches N/A N/A BACK STYLE Adjustable - 1-inch increments UPHOLSTERY Black nylon, black sail cloth, heavy vinyl BACK HEIGHT 15 to 19 inches in 1-inch increments SHIPPING WEIGHT (APPROX.) 46½ lbs 16x16-inch seat frame with complete package ARM STYLES Swing back or removable, space saver* or conventional, desk* or full length and in fixed* or adjustable height WEIGHT 36½ lbs HANDRIMS Steel*, aluminum and plastic coated WEIGHT LIMIT 350 lbs (154 kg) Part No. 1056953 13 Invacare® 9000 Series Wheelchair 2 OVERVIEW * These options are standard for this model. ** 9000 SL - The seat-to-floor heights are based on urethane tires. If wheelchair is equipped with pneumatic (properly inflated) or solid rubber tires, add ¼-inch to the measurements listed above. These heights can vary +/- ¼-inch due to tire wear and manufacturing tolerances. ** 9000 XT - The seat-to-floor heights are based on urethane tires. If wheelchair is equipped with pneumatic (properly inflated) or solid rubber tires, add ¼-inch to the measurements listed above. These heights can vary +/- ¼-inch due to tire wear and manufacturing tolerances. ** 9000 XT Recliner - The seat-to-floor heights are based on pneumatic tires and pneumatic tires with flat free inserts. If wheelchair is equipped with urethane tires, subtract ¼-inch from the measurements listed above. All heights are measured with properly inflated new tires. These heights can vary + ¼-inch due to tire wear. ** 9000 XDT - The seat-to-floor heights are based on pneumatic tires and pneumatic tires with flat free inserts. If wheelchair is equipped with urethane tires, subtract ¼-inch from the measurements listed above. All heights are measured with properly inflated new tires. These heights can vary + ¼-inch due to tire wear. Invacare® 9000 Series Wheelchair 14 Part No. 1056953 3 SAFETY 3 Safety The safety section contains important information for the safe operation and use of this product. 3.1 General Guidelines ! WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical personnel before attempting to use this equipment - otherwise, injury or damage may occur. A qualified technician MUST perform the initial set up of this wheelchair. also, a qualified technician must perform all procedures specifically indicated in the manual. ACCESSORIES WARNINGS Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products. NOTICE THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. Check all parts for shipping damage and test before using. In case of damage, DO NOT use. Contact Invacare/Carrier for further instruction. Part No. 1056953 15 Invacare® 9000 Series Wheelchair 3 SAFETY 3.2 Operating Information Anti-tippers WARNING Anti-tippers are specific to the different seat-to-floor angles and/or seat-to-floor heights. Refer to the charts in Installing/Adjusting Anti-tippers on page 62 for correct usage and adjustment. If these requirements cannot be achieved, DO NOT use the wheelchair. Contact a qualified technician. If changing the seat-to-floor height with or without a change to seat-to-floor angle, the correct anti-tippers MUST be used to maintain a 1½ to 2-inch ground clearance. Seat-to-floor angle of 0° or 3°: If so equipped, anti-tippers MUST be attached at all times. Inasmuch as the anti-tippers are an option for 0° or 3° on this wheelchair (you may order with or without the anti-tippers), Invacare strongly recommends ordering the anti-tippers as a safeguard for the wheelchair user. Seat-to-floor angle of 6°: If changing the seat-to-floor angle to 6°, anti-tippers MUST be installed. ALWAYS use anti-tippers. When outdoors on wet, soft ground or on gravel surfaces, anti tippers may not provide the same level of protection against tipover. Extra caution MUST be observed when traversing such surfaces. Invacare® 9000 Series Wheelchair 16 Part No. 1056953 3 SAFETY General Warnings WARNING To determine and establish your particular safety limits, practice bending, reaching and transferring activities in several combinations in the presence of a qualified healthcare professional before attempting active use of the wheelchair. Avoid storing or using the wheelchair near open flame or combustible products. Serious injury or damage to property may result. DO NOT stand on the frame of the wheelchair. DO NOT use the footplate as a platform. When getting in or out of the wheelchair, make sure that the footplates are in the upward position. ALWAYS use the handrims for self-propulsion. Inasmuch as the HANDRIMS are an option on this wheelchair (you may order with or without the handrims), Invacare strongly recommends ordering the handrims as an additional safeguard for the wheelchair user. Invacare recommends that a non-folding device be installed to keep the wheelchair from being folded when left unoccupied in a public place. DO NOT operate on roads, streets or highways. DO NOT allow children to play on or operate the wheelchair. DO NOT operate on soft surfaces such as sand, grass, or gravel. Part No. 1056953 17 Invacare® 9000 Series Wheelchair 3 SAFETY Hand Grips WARNING ALWAYS check hand grips for looseness before using the wheelchair. If loose and/or worn, replace IMMEDIATELY. When cleaning rear cane or hand grip areas use only a clean towel lightly dampened with cool water. Verify that grips are dry prior to use. Use of soap or ammonia based cleaning solutions will result in the hand grips sliding off the cane assembly. Failure to observe this warning may result in injury to the user or bystanders. If the wheelchair is exposed to extreme temperature (above 100°F or below 32°F), high humidity and/or becomes wet, prior to use, ensure that the handgrips DO NOT twist on the handle. Otherwise, damage or injury may occur. Information for Healthcare Professionals/Assistants WARNING When assistance to the wheelchair user is required, remember to use good body mechanics. Keep your back straight and bend your knees whenever tipping the wheelchair or traversing curbs, or other impediments. Make sure the patient is properly positioned in the wheelchair before reclining or inclining (reverse recline) to maintain maximum stability and safety. Refer to Safety/Handling of Wheelchairs on page 24. Make sure occupant's hands and body are clear of all pinch points before reclining back. Pinch points exist between spreader bar and recliner mechanism. Use caution, otherwise injury may occur. ALWAYS engage both wheel locks while reclining or inclining (reverse recline) the wheelchair. When returning the occupant of the reclining back wheelchair to the full upright position, more body strength will be required for approximately the last twenty degrees of incline (reverse recline). Make sure to use proper body mechanics (use your legs) or seek assistance if necessary to avoid injury. DO NOT attempt to recline or incline the wheelchair back without occupant. Back will raise abruptly and cause injury. Keep clear when reclining or inclining chair back to avoid injury. When learning a new assistance technique, have an experienced assistant help you before attempting it alone. Invacare® 9000 Series Wheelchair 18 Part No. 1056953 3 SAFETY Lifting WARNING DO NOT attempt to lift the wheelchair by any removable (detachable) parts. Lifting by means of any removable (detachable) parts of the wheelchair may result in injury to the user or damage to the wheelchair. 9000 XT RECLINER ONLY - DO NOT use the spreader bar to lift the wheelchair. Refer to Storing/Replacing Spreader Bar on page 75. Ramps, Slopes, Inclines, and Obstacles WARNING DO NOT traverse, climb or go down ramps or slopes greater than 9°. DO NOT attempt to move up or down an incline with a water, ice or oil film. DO NOT attempt to ride over curbs or obstacles. Doing so may cause your wheelchair to tip over and cause bodily harm to you or damage to the wheelchair. NEVER leave an unoccupied wheelchair on an incline. DO NOT attempt to stop the wheelchair while on a sloped surface. Repair and Service Information WARNING Unless otherwise noted, all service and adjustment should be performed while the wheelchair is unoccupied. Part No. 1056953 19 Invacare® 9000 Series Wheelchair 3 SAFETY Seat Positioning Straps WARNING ALWAYS wear your seat positioning strap. Inasmuch as the seat positioning strap is an option on this wheelchair (you may order with or without the seat positioning strap), Invacare strongly recommends ordering the seat positioning strap as an additional safeguard for the wheelchair user. The seat positioning strap is a positioning strap only. It is not designed for use as a safety device withstanding high stress loads such as auto or aircraft safety belts. If signs of wear appear, strap MUST be replaced IMMEDIATELY. With regards to seat/chest positioning straps - it is the obligation of the DME dealer, therapists and other healthcare professionals to determine if a seat/chest positioning strap is required to ensure the safe operation of this equipment by the user. Serious injury can occur in the event of a fall from a wheelchair. Stability (All Models) WARNING The seat depth, back height/angle, seat angle, size/position of the front casters, size/position of the rear wheels, anti-tipper model, as well as the user condition directly relate to the stability of the wheelchair. Any change to one or any combination of the ten may cause the wheelchair to decrease in stability. These adjustments must be performed by a qualified technician The various seat-to-floor heights require specific settings depending on rear wheel size, rear wheel position, front caster size/position and desired seat-to-floor angle. These adjustments MUST be performed by a qualified technician. Invacare® 9000 Series Wheelchair 20 Part No. 1056953 X X X X X X X X N/A X X X X N/A N/A N/A • X X X X X X N/A N/A N/A X • X X X X X X N/A • N/A N/A ANTITIPPERS X X WHEEL LOCKS X USER CONDITION X WHEEL POSITION • X WHEEL SIZE TILT ANGLE X CASTER POSITION SEATING SYSTEM X CASTER SIZE BACK ANGLE • TILT ANGLE SEAT DEPTH SEATING SYSTEM BACK HEIGHT BACK ANGLE When changes to the left hand column occur, follow across the chart and refer to the X procedure to maintain the proper stability, safety and handling of the wheelchair. SEAT DEPTH BACK HEIGHT 3 SAFETY N/A N/A N/A X N/A N/A N/A N/A N/A N/A N/A N/A N/A CASTER SIZE X N/A X N/A N/A • X X X N/A X X CASTER POSITION X N/A X N/A N/A X • X X N/A X X WHEEL SIZE X N/A X N/A N/A X X • X N/A X X WHEEL POSITION X N/A X N/A N/A X X X • N/A X X USER CONDITION X X X X X X X X X • SEAT HEIGHT X N/A X X X X X X X N/A Part No. 1056953 21 N/A N/A X X Invacare® 9000 Series Wheelchair 3 SAFETY Stability (Recliner Models Only) WARNING ALWAYS make sure that the wheelchair is stable before using the recliner option. Ensure the spreader bar is attached and secured before using the 9000XT Recliner. ALWAYS return the back to the upright position before lifting the wheelchair. LIFT KIT MODELS ONLY - Both spring lift mechanisms MUST be operational before using the recliner. DO NOT operate the recliner option if only one of the spring lift mechanisms is operational. LIFT KIT MODELS ONLY - DO NOT attempt to recline or incline the wheelchair back without occupant. Back will raise abruptly and cause injury. Keep clear when reclining or inclining chair back to avoid injury. Tire Pressure WARNING DO NOT use your wheelchair unless it has the proper tire pressure (p.s.i.). DO NOT overinflate the tires. Failure to follow these suggestions may cause the tire to explode and cause bodily harm. The recommended tire pressure is listed on the side wall of the tire. Weight Limitation WARNING The 9000 SL, 9000 XT, and 9000XT Recliner wheelchairs have a weight limitation of 250 lbs (114 kg). The 9000XDT wheelchair has a weight limitation of 350 lbs (159 kg). Invacare® 9000 Series Wheelchair 22 Part No. 1056953 3 SAFETY Weight Training WARNING Invacare does not recommend the use of its wheelchairs as a weight training apparatus. Invacare wheelchairs have not been designed or tested as a seat for any kind of weight training. If occupant uses said wheelchair as a weight training apparatus, Invacare shall not be liable for bodily injury or damage to the wheelchair and the warranty is void. Wheel Locks WARNING DO NOT attempt to stop a moving wheelchair with wheel locks. Wheel locks are not brakes. If the wheelchair is equipped with push to lock wheel locks, elevating legrests, and wheel lock extension handles, the wheel lock extension handles MUST be removed before swinging the elevating legrests to the side, otherwise injury or damage may result. Interference between the top of the elevating legrest and the wheel lock extension handle causes the wheel lock to disengage. Engaging the wheel locks may not prevent the wheelchair from moving on all floor surfaces including those that may be wet or slick. ALWAYS exercise caution when transferring into or out of the wheelchair. Wheelchair Tie Down Restraints WARNING Wheelchair users should NOT be transported in vehicles of any kind while in wheelchairs. As of this date, the Department of Transportation has not approved any tie-down systems for transportation of a user while in a wheelchair, in a moving vehicle of any type. It is Invacare’s position that users of wheelchairs should be transferred into appropriate seating in vehicles for transportation and use be made of the restraints made available by the auto industry. Invacare cannot and does not recommend any wheelchair transportation systems. Part No. 1056953 23 Invacare® 9000 Series Wheelchair 3 SAFETY Wheelchair User 3.3 WARNING As a manufacturer of wheelchairs, Invacare endeavors to supply a wide variety of wheelchairs to meet many needs of the end user. However, final selection of the type of wheelchair to be used by an individual rests solely with the user and his/her healthcare professional capable of making such a selection. Safety/Handling of Wheelchairs Safety and handling of the wheelchair require the close attention of the wheelchair user as well as the assistant. This manual points out the most common procedures and techniques involved in the safe operation and maintenance of the wheelchair. It is important to practice and master these safe techniques until you are comfortable in maneuvering around the frequently encountered architectural barriers. Use this information only as a basic guide. The techniques that are discussed on the following pages have been used successfully by many. Individual wheelchair users often develop skills to deal with daily living activities that may differ from those described in this manual. Invacare recognizes and encourages each individual to try what works best for him/her in overcoming architectural obstacles that they may encounter. However, all warnings and cautions given in this manual MUST be heeded. Techniques in this manual are a starting point for the new wheelchair user and assistant with “safety” as the most important consideration for all. Stability and Balance WARNING Be aware that carrying heavy objects on your lap while occupying the wheelchair may adversely affect the stability of the wheelchair, resulting in serious bodily injury to the user, damage to the wheelchair and surrounding property. This wheelchair has been designed to accommodate one individual. If more than one individual occupies the wheelchair this may adversely affect the stability of the wheelchair, resulting in serious bodily injury to the user and passenger and damage to the wheelchair and surrounding property. To assure stability and proper operation of your wheelchair, you MUST maintain proper balance at all times. Your wheelchair has been designed to remain upright and stable during normal daily activities as long as you DO NOT move beyond the center of gravity. Virtually all activities which involve movement in the wheelchair have an effect on the center of gravity. Invacare recommends using seat/chest positioning straps for additional safety while involved in activities that shift your weight. Invacare® 9000 Series Wheelchair 24 Part No. 1056953 3 SAFETY DO NOT lean forward out of the wheelchair any further than the length of the armrests. Make sure the casters are pointing in the forward position whenever you lean forward. This can be achieved by advancing the wheelchair and then reversing it in a straight line. Many activities require the wheelchair owner to reach, bend and transfer in and out of the wheelchair. These movements will cause a change to the normal balance, the center of gravity, and the weight distribution of the wheelchair. To determine and establish your particular safety limits, practice bending, reaching and transferring activities in several combinations in the presence of a qualified healthcare professional before attempting active use of the wheelchair. Proper positioning is essential for your safety. When reaching, leaning, or bending forward, it is important to use the front casters as a tool to maintain stability and balance. Reaching, Leaning and Bending WARNING DO NOT shift your weight or sitting position toward direction you are reaching as the wheelchair may tip over. DO NOT attempt to reach objects if you have pick them up from the floor by reaching down between your knees. DO NOT lean over the top of the back upholstery to reach objects behind you, as this may cause the wheelchair to tip over. Forward Position the front casters so that they are extended as far forward as possible and engage wheel locks. Backwards Position wheelchair as close as possible to the desired object. Point front casters forward to create the longest possible wheelbase. Reach back only as far as your arm will extend without changing your sitting position. FIGURE 1 Backwards Part No. 1056953 25 Invacare® 9000 Series Wheelchair 3 SAFETY Coping With Everyday Obstacles Coping with the irritation of everyday obstacles can be alleviated somewhat by learning how to manage your wheelchair. Keep in mind your center of gravity to maintain stability and balance. Tipping WARNING DO NOT tip the wheelchair without assistance. When lowering the front casters of the wheelchair, Do not let the wheelchair drop the last few inches to the ground. This could result in injury to the occupant and/or damage to the wheelchair. When tipping the wheelchair, an assistant should grasp the back of the wheelchair on a non-removable (non-detachable) part. Inform the wheelchair occupant before tipping the wheelchair and remind him/her to lean back. Be sure the occupant’s feet and hands are clear of all wheels and/or pinch points. After mastering the techniques of tipping the wheelchair, use one of the following methods to tackle curbs, short stairs, etc. Method 1 - Wheelchair With Step Tubes Place foot on the step tube and begin to tilt the wheelchair toward you. Apply a continuous downward motion until the balance point is achieved and the front casters clear the curb. At this point, the assistant will feel a difference in the weight distribution. Roll the wheelchair forward and slowly lower the front of the wheelchair in one continuous movement onto the sidewalk. Push the wheelchair forward until the rear wheels roll up and over the curb. Step Tube FIGURE 2 Method 1 - Wheelchair With Step Tubes Invacare® 9000 Series Wheelchair 26 Part No. 1056953 3 SAFETY Method 2 - Wheelchair Without Step Tubes This method requires two assistants. The second assistant should be positioned at the front of the wheelchair lifting upward on a non-removable (non-detachable) part of the wheelchair frame when lifting the wheelchair and stabilizing the wheelchair when the wheelchair is being lowered to the ground. The first assistant should stand on the sidewalk and turn the wheelchair so that the rear wheels are against the curb. Turn the anti-tippers so the anti-tip wheels are pointing up. The wheelchair should be tilted back to the balance point and, in one continuous upward movement, the rear wheels should be pulled up and over the curb. DO NOT return the front casters to the ground until the wheelchair has been pulled backward far enough for the front casters to clear the edge of the curb. Roll the wheelchair backward and slowly lower the wheelchair in one continuous movement. Turn the anti-tippers so the anti-tip wheels are facing down. FIGURE 3 Method 2 - Wheelchair Without Step Tubes Stairways WARNING Extreme caution is advised when it is necessary to move an occupied or unoccupied wheelchair up or down the stairs. Invacare recommends that, if possible, the user be removed from the wheelchair prior to moving. Invacare recommends using two assistants and making thorough preparations. Make sure to use only secure, non-detachable parts for hand-held supports. 9000 XT recliner only - ALWAYS return the back to the upright position before lifting the wheelchair. Follow this procedure for moving the wheelchair between floors when an elevator is not available: Moving Up Stairs 1. If necessary, rotate the anti-tippers so the wheels are facing up. Part No. 1056953 27 Invacare® 9000 Series Wheelchair 3 SAFETY 2. One assistant (positioned behind the wheelchair), securely grasps a non-removable (non-detachable) part of the wheelchair for leverage and tilts the wheelchair back to the balance point. 3. After the wheelchair has been tilted back to the balance point, the assistant behind the wheelchair backs the wheelchair up against the first step. 4. The second assistant (positioned in the front of the wheelchair), with a firm hold on a non-detachable part of the framework, lifts the wheelchair up and on to the next stair above and steadies the wheelchair as the assistant behind the wheelchair places one foot on the next stair above and repeats process. 5. The wheelchair should not be lowered until the last stair has been negotiated and the wheelchair has been rolled away from the stairway. 6. If necessary, rotate the anti-tippers so the wheels are facing down. Moving Down Stairs 1. If necessary, rotate the anti-tippers so the wheels are facing up. 2. One assistant (positioned behind the wheelchair), securely grasps a non-removable (non-detachable) part of the wheelchair for leverage and tilts the wheelchair back to the balance point. 3. After the wheelchair has been tilted back to the balance point, the assistant behind the wheelchair rolls the wheelchair up to the edge of the first step. 4. The second assistant (positioned in the front of the wheelchair), with a firm hold on a non-detachable part of the framework, lowers the wheelchair down and on to the next stair below and steadies the wheelchair as the assistant in the rear places one foot on the next stair below and repeats process. 5. The wheelchair should not be lowered until the last stair has been negotiated and the wheelchair has been rolled away from the stairway. 6. If necessary, rotate the anti-tippers so the wheels are facing down. FIGURE 4 Stairways Invacare® 9000 Series Wheelchair 28 Part No. 1056953 3 SAFETY Escalators WARNING DO NOT use an escalator to move a wheelchair between floors. Serious bodily injury may occur. Transferring To and From Other Seats WARNING CAUTION Before attempting to transfer in or out of the wheelchair, every precaution should be taken to reduce the gap distance. Turn both casters parallel to the object you are transferring onto. Also be certain the wheel locks are engaged to help prevent the wheels from moving. When transferring, position yourself as far back as possible in the seat. This will help prevent damaged upholstery and the possibility of the wheelchair tipping forward. This activity may be performed independently provided you have adequate mobility and upper body strength. Position the wheelchair as close as possible alongside the seat to which you are transferring, with the front casters pointing parallel to it. Remove or flip up the armrest. Engage wheel locks. Swing away or remove front rigging. Shift body weight into seat with transfer. During independent transfer, little or no seat platform will be beneath you. Use a transfer board if at all possible. Part No. 1056953 FIGURE 5 Transferring To and From Other Seats 29 Invacare® 9000 Series Wheelchair 3 SAFETY Unfolding and Folding Wheelchair WARNING ALWAYS keep hands and fingers clear of moving parts to avoid injury. DO NOT place hand or fingers on the underside of the seat frame rail when opening or closing the wheelchair. DO NOT sit or transfer into the wheelchair unless it is fully open and the seat frame rails are fully seated into the side frame H-blocks. Unfolding 1. 2. Tilt the wheelchair toward you (raising the opposite wheel and caster off the ground/floor). Place your hand on the top of the seat rail closest to you where the seat upholstery is attached. 3. Point your fingers and thumb to the inside of the wheelchair. 4. Press downward on the top of the seat rail until the wheelchair is fully open and the seat rails are fully seated in the H-blocks. 5. 9000 XT RECLINERS ONLY - Secure the detached end of the spreader bar to the side frame. Refer to Storing/Replacing Spreader Bar on page 75. 6. Engage both wheel locks, open the footrest/legrest for clearance and transfer into the wheelchair. Refer to Transferring To and From Other Seats on page 29. Invacare® 9000 Series Wheelchair Press DOWN on Seat Rail FIGURE 6 Unfolding and Folding Wheelchair 30 Part No. 1056953 3 SAFETY Folding Hammock or Sling Seat Models 1. 2. 9000 XT RECLINERS ONLY - Detach one end of the spreader bar from the side frame. Refer to Storing/Replacing Spreader Bar on page 75. Swing footrest/legrest in locked position to the front of the wheelchair. 3. Pivot footplates upward to vertical position. 4. With both hands, grasp the middle of the seat upholstery at the front and back edge and lift up. 5. Continue to close the wheelchair by grasping the armrest furthest from you and pulling the armrest towards you. FIGURE 7 Folding Hammock or Sling Seat Models Folding Solid-Seat Models 1. 2. 9000 XT RECLINERS ONLY - Detach one end of the spreader bar from the side frame. Refer to Storing/Replacing Spreader Bar on page 75. Swing footrest/legrest in locked position to the front of the wheelchair. 3. Pivot footplates upward to vertical position. 4. From behind the wheelchair, grasp the right hand edge of the solid seat. 5. Raise the seat to the hinged side. 6. With both hands, grasp the middle of the front and back edges of the solid folding seat and lift up until the wheelchair begins to close. 7. Continue to close the wheelchair by grasping the armrest furthest from you and pulling the armrest towards you. Part No. 1056953 FIGURE 8 Folding Solid-Seat Models 31 Invacare® 9000 Series Wheelchair 4 SAFETY INSPECTION/TROUBLESHOOTING 4 Safety Inspection/troubleshooting 4.1 Every six months or as necessary, take your wheelchair to a qualified technician for a thorough inspection and servicing. Regular cleaning will reveal loose or worn parts and enhance the smooth operation of your wheelchair. To operate properly and safely, your wheelchair MUST be cared for just like any other vehicle. Routine maintenance will extend the life and efficiency of your wheelchair. Safety Inspection Checklist Initial adjustments should be made to suit your personal body structure and preference. Thereafter follow these maintenance procedures: Inspect/Adjust Initially ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Ensure that the wheelchair rolls straight (no excessive drag or pull to one side). Inspect for loose or missing hardware on frame and crossbraces. Inspect for bent frame or crossbraces. Check that the wheel locks DO NOT interfere with tires when rolling. Check that the wheel lock pivot points are free of wear and looseness. Check that the wheel locks are easy to engage. Ensure that the wheel locks prevent the wheelchair from moving when engaged. Inspect the seat and back for rips and sagging. Inspect the seat and back for loose or broken hardware. Inspect the back cane hand grips for wear/looseness/deterioration. Inspect seat positioning strap for any signs of wear. Ensure buckle latches. Verify hardware that attaches strap to frame is secure and undamaged. Replace if necessary. Inspect tires for flat spots and wear. Check pneumatic tires for proper inflation. Invacare® 9000 Series Wheelchair 32 Part No. 1056953 4 SAFETY INSPECTION/TROUBLESHOOTING ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ CAUTION As with any vehicle, check the wheels and tires periodically for cracks and wear. Replace if damaged. If equipped, check that quick-release axles lock properly. Lubricate if necessary. Check that there is no excessive side movement or binding in the rear wheels when lifted and spun. Inspect rear wheels for cracked, bent or broken spokes. Ensure all spokes are uniformly tight. Inspect handrims for signs of rough edges or peeling. Inspect axle assembly for proper tension by spinning caster. Caster should come to a gradual stop. Adjust front casters/forks bearing system if wheel wobbles noticeably or binds to a stop. Ensure wheel bearings are clean and free of moisture. Check headtube locknuts for tightness. Inspect casters for cracks and wear. Inspect front casters for cracked, bent or broken spokes. Clean upholstery and armrests. Inspect/Adjust Weekly ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Ensure that the wheel locks prevent the wheelchair from moving when engaged. Inspect tires for flat spots and wear. Check pneumatic tires for proper inflation. If equipped, check that quick-release axles lock properly. Lubricate if necessary. Inspect rear wheels for cracked, bent or broken spokes. Ensure all spokes are uniformly tight. Inspect axle assembly for proper tension by spinning caster. Caster should come to a gradual stop. Inspect front caster for cracked, bent or broken spokes. Part No. 1056953 33 Invacare® 9000 Series Wheelchair 4 SAFETY INSPECTION/TROUBLESHOOTING Inspect/Adjust Monthly ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Ensure that the wheelchair rolls straight (no excessive drag or pull to one side). Check that the wheel locks DO NOT interfere with tires when rolling. Check that the wheel lock pivot points are free of wear and looseness. Inspect seat and back for loose or broken hardware. Inspect seat positioning strap for any signs of wear. Ensure buckle latches. Verify hardware that attaches strap to frame is secure and undamaged. Replace if necessary. Inspect back cane hand grips for wear/looseness/deterioration. Adjust front casters/forks bearing system if wheel wobbles noticeably or binds to a stop. Ensure wheel bearings are clean and free of moisture. Check headtube locknuts for tightness. Inspect/Adjust Periodically ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Inspect frame and crossbraces for loose or missing hardware. Inspect for bent frame or crossbraces. Check that wheel locks are easy to engage. Inspect seat and backs for rips and sagging. Check that there is no excessive side movement or binding in the rear wheels when lifted and spun. Inspect handrims for signs of rough edges or peeling. Adjust front casters/forks bearing system if wheel wobbles noticeably or binds to a stop. Inspect casters for cracks and wear. Ensure that casters are free of debris. Ensure wheel bearings are clean and free of moisture. Clean upholstery and armrests. Check that all labels are present and legible. Replace if necessary. Invacare® 9000 Series Wheelchair 34 Part No. 1056953 4 SAFETY INSPECTION/TROUBLESHOOTING 4.2 Troubleshooting Chair Veers Right/Left X X X Part No. 1056953 Chair 3 Wheels X X Sluggish Turn or Performance Casters Flutter X X X X Squeaks and Rattles Looseness in Chair Solutions Check tires for correct and equal pressure X X Check for loose nuts and bolts. Check caster headtube angle. X Check that rear wheels are equally spaced away from seat frame. X 35 Invacare® 9000 Series Wheelchair 4 SAFETY INSPECTION/TROUBLESHOOTING 4.3 Maintenance Maintenance Safety Precautions WARNING After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Otherwise injury or damage may result. Replace any labels that are missing, worn, or torn. Refer to Label Locations on page 8 for a listing of the labels and their locations. CAUTION DO NOT overtighten hardware attaching to the frame. This could cause damage to the frame tubing. Suggested Maintenance Procedures 1. Before using your 9000 Series wheelchair, make sure all nuts and bolts are tight. 2. Check all parts for damage or wear and replace. 3. Check all parts for proper adjustment. 4. 9000 SL/9000 XT ONLY - Keep quick-release axles free of dirt and lint to ensure positive locking and proper operation. Refer to Adjusting Quick-Release Axle on page 58. 5. 9000 SL/9000 XT ONLY - Oil quick-release axles at least once a month (3-in-1 oil® or equivalent). WARNING Do not use the wheelchair unless it has the proper tire pressure (p.s.i.). DO NOT overinflate the tires. Failure to follow these suggestions may cause the tire to explode and cause bodily harm. The recommended tire pressure is listed on the sidewall of the tire. Invacare® 9000 Series Wheelchair 36 Part No. 1056953 4 SAFETY INSPECTION/TROUBLESHOOTING CAUTION As with any vehicle, check the wheels and tires periodically for cracks and wear. Replace if damaged. Replace as recommended, refer to Replacing/Repairing Rear Wheel Tire/Tube on page 38 and Replacing/Repairing Caster Tire/Tube on page 38. 6. The rear wheels, casters and tires should be checked periodically for cracks and wear, and should be replaced by a qualified technician if damaged 7. Periodically adjust wheel locks in correlation to tire wear. Refer to Adjusting Patient-Operated Wheel Locks on page 66. Tire wear is excessive if: Pneumatic Tires - there is missing tread or the tires are bald. Urethane Tires - there are cuts, surface defects or the tires are loose on the rims. Rubber Tires - 30% or more of the tire has worn away. Invacare recommends that tires and casters be replaced every five years. 8. Periodically check handrims to ensure they are secured to the rear wheels. If loose, have them tightened by a qualified technician. 9. Periodically check caster wheel bearings to make sure they are clean and free from moisture. Use a Teflon® lubricant if necessary. 10. Check upholstery for sagging, rips or tears. 11. Clean upholstery with mold soap and water 12. Hand grips should be checked monthly for wear/looseness/deterioration. Clean if desired. Replace if looseness or deterioration is found. Part No. 1056953 37 Invacare® 9000 Series Wheelchair 4 SAFETY INSPECTION/TROUBLESHOOTING Replacing/Repairing Rear Wheel Tire/Tube WARNING Replacement of solid urethane tires is not recommended. If the solid urethane tire needs repaired, Invacare recommends replacing the complete wheel assembly. Replacement of rear wheel tube must be performed by a qualified technician. Replacing/Repairing Caster Tire/Tube WARNING Replacement of solid urethane or semi-pneumatic tires is not recommended. If the solid urethane or semi-pneumatic tires need replaced, Invacare recommends replacing complete caster assembly. For pneumatic tires, replacement of the tire or tube must be performed by a qualified technician. Invacare® 9000 Series Wheelchair 38 Part No. 1056953 5 FRONT RIGGINGS 5 Front Riggings 5.1 WARNING After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Otherwise injury or damage may occur. Installing/Removing Front Riggings Installing 1. Turn the front rigging assembly to the side (open front rigging is perpendicular to wheelchair). 2. Install the hinge plates of the front rigging assembly onto the hinge pins on the wheelchair frame. 3. When performing STEP 3, it may be necessary to pull release lever toward front of chair to assist the front rigging to lock in place. Push the front rigging assembly towards the inside of the wheelchair until it locks into place. The footplate will be on the inside of the wheelchair when locked in place. 4. Repeat this procedure for the other front rigging assembly. 5. To release the front rigging, push the front rigging release lever inward, rotate front rigging outward. Removing 1. Push the front rigging release lever inward. 2. Rotate swingaway front rigging assembly outward. 3. Lift the swingaway front rigging assembly off the hinge pins. Part No. 1056953 39 Invacare® 9000 Series Wheelchair 5 FRONT RIGGINGS Front Rigging Release Lever Front Rigging Assembly Hinge Pins Hinge Plates Footplate Swingaway footrest shown. FIGURE 1 Installing/Removing Front Riggings Invacare® 9000 Series Wheelchair 40 Part No. 1056953 5 FRONT RIGGINGS 5.2 Adjusting Footplate Height Spring Button Height 1. Front Rigging Support Remove the front rigging assembly. Refer to Installing/Removing Front Riggings on page 39. 2. This procedure applies to the swingaway front riggings and swingaway elevating legrest. Lay the front rigging assembly on a flat surface to simplify this procedure. Release Button Adjustment Holes Pull the cam lock lever up to unlocked position. The elevating legrest has two sets of release buttons, one set above the other. Each set will be visible one at a time allowing finer footplate height adjustment. 3. Push in the release buttons and reposition the footplate assembly to the desired height. 4. Ensure that the release buttons fully protrude from holes on both sides of the front rigging support. Cam Lock Lever Swingaway footrest shown. 5. Rotate cam lock lever down to locked position. 6. Repeat this procedure for the other footplate, if necessary. 7. Reinstall the swingaway front rigging assembly. Refer to Installing/Removing Front Riggings on page 39. Part No. 1056953 Footplate Assembly FIGURE 2 Spring Button Height 41 Invacare® 9000 Series Wheelchair 5 FRONT RIGGINGS Bolt-In-Place Height 1. Remove the swingaway front rigging. Refer to Installing/Removing Front Riggings on page 39. 2. This procedure applies to the swingaway front riggings and swingaway elevating legrest. Lay the front rigging assembly on a flat surface to simplify this procedure. Pull the cam lock lever up to position. 3. Using a screw driver to hold the threaded rivet in position, remove the button head screw from the threaded rivet. 4. Remove the threaded rivet and button head screw securing the footplate assembly to the front rigging support. 5. Adjust the footplate assembly height by aligning the desired adjustment holes in the upper front rigging support and lower footplate assembly. 6. From the outside of the swingaway front rigging, insert the threaded rivet through both the front rigging support and the footplate assembly. 7. From the inside of the swingaway front rigging, insert the button head screw through the appropriate adjustment hole and thread into the threaded rivet. 8. Using a screwdriver to hold the threaded rivet in position, securely tighten the button head screw. Torque to 32 in-lbs. 9. Rotate cam lock lever down to locked position. 10. Repeat STEPS 1-9 to adjust the remaining footrest. Invacare® 9000 Series Wheelchair 42 Part No. 1056953 5 FRONT RIGGINGS Threaded Rivet Threaded Rivet Adjustment Hole Inside of Swingaway Front Rigging Front Rigging Support Front Rigging Support Button Head Screw Cam Lock Lever Button Head Screw Footplate Assembly Footplate Assembly Adjustment Hole Outside of Swingaway Front Rigging Swingaway footrest shown. FIGURE 3 Bolt-In-Place Height 5.3 Raising/Lowering Elevating Legrest Assembly C. WARNING Release Lever Ensure hands and fingers are clear of elevating legrest mechanism before pushing release lever to lower the elevating legrest. Otherwise injury may occur due to pinch points. Support Tube The wheelchair user’s leg MUST be supported by an assistant before attempting to lower legrest. 1. 2. Gently, lower user leg down and rest against the legrest. To raise the elevating legrest, the assistant should hold the support tube and raise the elevating legrest until the desired height is obtained. To lower the elevating legrest, perform the following: A. Support user leg with one hand. B. Push release lever downward with other hand. Part No. 1056953 FIGURE 4 Raising/Lowering Elevating Legrest Assembly 43 Invacare® 9000 Series Wheelchair 5 FRONT RIGGINGS 5.4 Installing Impact Guards/Calf Strap. 1. Remove impact guard/calf strap from packaged container if not already secured to the footrest. 2. Secure one impact guard to the each footrest. 3. Ensure the upper portion of the impact guard is between the two horizontal supports of the footrest. Secure one side of the calf strap around each footrest (with the impact guards attached, if present). Horizontal Support Calf Strap Footrest Notch Upper Portion of Impact Guard Horizontal Support Impact Guard FIGURE 5 Installing Impact Guards/Calf Strap. 5.5 Replacing Heel Loop 1. Pull the cam lock lever up to unlocked position. 2. Perform one of the following as shown in Detail “A”. • • 3. Footplates with Spring Buttons: Push in the release buttons and remove the footplate assembly from the front rigging support. Bolt-In-Place Footplates: i. Using a screw driver to hold the threaded rivet in position, remove the button head screw from the threaded rivet. ii. Remove the threaded rivet and button head screw securing the footplate assembly to the front rigging support. Remove the mounting screw, spacer and locknut that secure the heel loop to the footplate. 4. Remove existing heel loop from slide tube. Invacare® 9000 Series Wheelchair 44 Part No. 1056953 5 FRONT RIGGINGS 5. Install new heel loop onto slide tube. 6. Install the mounting screw, spacer and locknut to secure the heel loop to the footplate. Tighten until the spacer is secure. 7. Insert the lower footrest assembly into the upper footrest assembly to desired height. 8. Perform one of the following as shown in Detail “A”: • • Footplates With Spring Buttons: Ensure that the release buttons fully protrude from holes on both sides of the upper footrest support. Bolt-In-Place Footplates: i. From the outside of the swingaway front rigging, insert the threaded rivet through both the front rigging support and the footplate assembly. ii. From the inside of the swingaway front rigging, insert the button head screw through the appropriate adjustment hole and thread into the threaded rivet. iii. Using a screwdriver to hold the threaded rivet in position, securely tighten the button head screw. Torque to 32 in-lbs. 9. Rotate cam lock lever down to locked position. g Threaded Bolt-in-Place Footplates Cam Lock Screw Footplates with Spring Buttons DETAIL “A” Rivet Lever Button Head Front Rigging Support Front Rigging Screw Heel Loop Support Slide Tube Release Button Footplate Assembly Adjustment Holes Inside of Swingaway Front Rigging Cam Lock Lever Swingaway footrest shown. Part No. 1056953 Cam Lock Lever Outside of Swingaway Front Rigging Spacer Footplate Assembly Adjustment Hole Footplate Assembly Footplate Assembly Locknut Footplate FIGURE 6 Replacing Heel Loop 45 Invacare® 9000 Series Wheelchair 6 ARMS 6 Arms 6.1 2. 4. WARNING Armrest Height Adjustment Lever Make sure the height adjustment lever is in the locked position before using the wheelchair. Unlock the armrest by flipping the height adjustment lever on the top front of the armrest to the up (horizontal) position. Adjust armrest to one of five positions. 3. After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Otherwise injury or damage may occur. Adjusting Armrest Height 1. WARNING Locked (Vertical) Height adjustment lever MUST be in the unlocked position when placing armrest into the arm assembly. Lock the armrest by pressing the height adjustment lever into the down (vertical) position when the desired armrest height is achieved. Unlocked (Horizontal) FIGURE 1 Adjusting Armrest Height Repeat STEPS 1-3 for other armrest. Invacare® 9000 Series Wheelchair 46 Part No. 1056953 6 ARMS 6.2 Using Swing-Back Arms 1. 2. 3. Make sure the armrest release lever is in the locked position before using the wheelchair. This procedure applies to 9000SL, 9000XT, and 9000XDT wheelchairs only. Front Swing Back Arm Armrest Release Lever Unlock the swing-back arms by rotating the armrest release lever toward the outside of the wheelchair. Pull the front of the swing-back arm straight up/out of the arm socket and towards the rear of the wheelchair. To use the swing-back arm, push the swing-back arm towards the front of the wheelchair and then downward into the arm socket. 4. WARNING Armrest release lever MUST be in the unlocked position when placing armrest into the arm sockets. Rear Arm Socket Lock the swing-back arms by rotating the armrest release lever towards the inside of the wheelchair. Part No. 1056953 FIGURE 2 Using Swing-Back Arms 47 Invacare® 9000 Series Wheelchair 6 ARMS 6.3 Removing or Replacing Armrest WARNING 9000XDT: Use only heavy duty, fixed height armrests on 9000XDT wheelchairs. Otherwise injury or damage may occur. Make sure the armrest release lever is in the locked position before using the wheelchair. This procedure does not apply to 9000 SL wheelchairs equipped with space saver arms. Removing Armrests 1. 2. Armrest Unlock the armrest by turning the armrest release levers towards the outside of the wheelchair. Lift armrest completely out of arm sockets from the wheelchair. Rear Arm Post Replacing Armrests 1. 2. Armrest Release Lever Armrest release lever MUST be in the unlocked position when placing armrest into the arm sockets. Arm Socket Place armrest into arm sockets located on the side of the wheelchair. Lock the armrest by turning the armrest release levers towards the inside of the wheelchair. Invacare® 9000 Series Wheelchair Armrest Release Lever Arm Socket FIGURE 3 Removing or Replacing Armrest 48 Part No. 1056953 6 ARMS 6.4 Replacing Desk/Full Length Armrest Pad (Fixed Height Arms Only) 1. 2. Mounting Screws Remove the mounting screws that secure the armrest pad to the armrest assembly. Replace armrest pad and securely tighten with the existing mounting screws. Armrest Assembly 6.5 Replacing Clothing Guards (Fixed Height Arms Only) 1. 2. Clothing Guard Remove the four mounting screws that secure the existing clothing guard to the armrest assembly. Install new clothing guard and securely tighten with the existing mounting screws. 6.6 Mounting Screws Mounting Screws FIGURE 4 Replacing Desk/Full Length Armrest Pad (Fixed Height Arms Only) Converting Between Space Saver and Conventional Arms Space Saver arms DO NOT work with 9000XT/9000SL with the adjustable angle back option and 9000XT Recliner. 1. Remove the arms from the wheelchair. Refer to Removing or Replacing Armrest on page 48. 2. Remove the locknut and hex screw that secure the arm socket to the wheelchair frame. 3. Repeat STEP 2 for the opposite side of the wheelchair. 4. Reposition the arm socket to one of two positions: A. For conventional arms - position arm socket on outside of frame. B. For space saver arms - position arm socket on inside of frame. 5. Armrest Pad Make sure arm sockets sit flush against the wheelchair frame. Reinstall the hex screw and locknut that secure the arm socket to the wheelchair frame and securely tighten. Part No. 1056953 49 Invacare® 9000 Series Wheelchair 6 ARMS 6. Repeat STEP 5 for the opposite side of the wheelchair. 7. Install the new arms onto the wheelchair. Refer to Removing or Replacing Armrest on page 48. 8. The rear wheel axle spacer is needed for conventional arms. It is not needed for spacer saver arms. For conventional arms, refer to Removing/Installing Rear Wheels on page 55. Space Saver Arm Position Arm Socket (Inside of Wheelchair Frame) Arm Socket (Outside of Wheelchair Frame) Hex Screw Locknut Locknut Left Side of Wheelchair Frame Wheelchair Frame Conventional Arm Position Hex Screw Right Side of Wheelchair Frame FIGURE 5 Converting Between Space Saver and Conventional Arms Invacare® 9000 Series Wheelchair 50 Part No. 1056953 7 SEAT AND BACK 7 Seat and Back 7.1 1. WARNING After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Otherwise injury or damage may occur. The procedures in this section apply to non-recliner models only. For 9000XT recliner models, refer to Recliner on page 70. Replacing Seat Upholstery Remove the mounting screws that secure the existing seat upholstery to the wheelchair frame. 16 inch seat depth has 8 mounting screws and 17-20 inch seat depths have 10 mounting screws. 2. Remove the existing seat upholstery from the wheelchair frame. 3. Install new seat upholstery by reversing STEPS 1-2. 16-inch Seat Depth Mounting Screws Seat Upholstery Wheelchair Frame FIGURE 1 Replacing Seat Upholstery Part No. 1056953 51 Invacare® 9000 Series Wheelchair 7 SEAT AND BACK 7.2 Replacing Back Upholstery Screw-On Back Upholstery 1. 2. Back Upholstery Mounting Screws Back Cane Flip swing-back arms up and out of the way. Refer to Using Swing-Back Arms on page 47. Remove the six mounting screws and washers that secure the existing back upholstery to the back canes. 3. Cut the tie wraps that secure the existing back upholstery to the wheelchair frame. 4. Securely tighten the new back upholstery to the back canes with the six mounting screws and washers starting with the top hole of the back cane. 5. Install two new tie wraps through the bottom holes of the upholstery to tie the bottom of the back upholstery to the back canes. 6. Washers This procedure applies to 9000 SL without adjustable back angle option. Tie Wraps Flip swing-back arms down for use. Refer to Using Swing-Back Arms on page 47. Washers Mounting Screws FIGURE 7.1 Replacing Back Upholstery - Screw-On Back Upholstery Slip-On Back Upholstery 1. This procedure applies to 9000 XT/XDT and 9000 SL with adjustable back angle option. Remove the two mounting screws and washers that secure the existing back upholstery to the back canes (Detail “A”). Invacare® 9000 Series Wheelchair 52 Part No. 1056953 7 SEAT AND BACK 2. Remove the two mounting screws, spacers and locknuts that secure one back cane to the wheelchair frame (Detail “B”). It is necessary to remove only one back cane to replace the back upholstery. 3. Pull the loose back cane out of the existing back upholstery. 4. Pull the existing back upholstery up and over the mounted back cane. 5. Install the new back upholstery over the mounted back cane. 6. Slide the loose back cane through the new back upholstery. 7. Secure the back cane to the wheelchair frame with the two mounting screws, spacers and locknuts. 8. The spacers MUST be on the outside of the wheelchair in order to properly tighten the mounting screws. Secure the new back upholstery to the back canes with the existing mounting screws and washers. DETAIL “A” DETAIL “B” Back Upholstery Washer Back Cane Mounting Screws Spacers Wheelchair Frame Locknuts Mounting Screws Back Cane FIGURE 8 Replacing Back Upholstery - Slip-On Back Upholstery Part No. 1056953 53 Invacare® 9000 Series Wheelchair 7 SEAT AND BACK 7.3 Adjusting Back Height, Back Angle or Seat Depth 7.4 WARNING The seat depth, back height/angle, seat angle, size/position of the front casters, size/position of the rear wheels, anti-tipper model, as well as the user condition directly relate to the stability of the wheelchair. Any change to one or any combination of the ten may cause the wheelchair to decrease in stability. These adjustments must be performed by a qualified technician. Adjusting Seat Width WARNING Adjusting the seat width of the 9000SL, 9000XT, 9000XDT MUST be performed by a qualified technician. Invacare® 9000 Series Wheelchair 54 Part No. 1056953 8 REAR WHEELS 8 Rear Wheels 8.1 WARNING After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Otherwise injury or damage may occur. Except where noted, the procedures in this section apply to non-recliner models only. For recliner models, refer to Recliner on page 70. Removing/Installing Rear Wheels WARNING Only a qualified technician may change the size of the rear wheel or the seat-to-floor height. Permanent Axles WARNING If the wheelchair is equipped with permanent axles, removal/installation of the rear wheels MUST be performed by a qualified technician. Quick-Release Axles WARNING NEVER use quick-release axles on the 9000 XT (models with offset axle option only), 9000XDT or 9000XT recliner wheelchairs. If replacing the same size rear wheel, note the mounting position on the wheelchair frame for proper reinstallation of the new rear wheel. Part No. 1056953 55 Invacare® 9000 Series Wheelchair 8 REAR WHEELS 1. Push in the detent pin of quick-release axle (with wheel) and pull the axle out through the opening in the center of the rear wheel and axle spacer. Axle spacer is used only if wheelchair is equipped with conventional arms. 2. Push in the detent pin of the quick-release axle again and pull the axle out of the rear wheel. 3. Repeat STEPS 1-2 for the opposite rear wheel. 4. To reinstall the rear wheel onto the wheelchair, reverse STEPS 1-3. Make sure axle spacer is between rear wheel and wheelchair frame if wheelchair is equipped with conventional arms. WARNING Make sure the detent pin and detent balls of the quick-release axle are fully released before operating the wheelchair. The detent balls MUST be protruding past the inside of the rear wheel axle bushing for a positive lock (Detail "A"). Keep detent balls clean. Invacare recommends inserting quick-release axles with the detent pin to the inside of the wheelchair to prevent accidental release during contact activities. 5. If the detent balls are not protruding past the inside of the axle bushing or there is too much side-to-side movement of the rear wheel assembly, refer to Adjusting Quick-Release Axle on page 58. Invacare® 9000 Series Wheelchair 56 Part No. 1056953 8 REAR WHEELS 0 DETAIL “A” DETENT BALLS AND DETENT PIN Detent Pin Axle Bushing Detent Balls Axle Mounting Positions Axle Spacer (Conventional Arms Only) Quick-Release Axle Inside of Wheelchair Quick-Release Axle Wheelchair Frame Outside of Wheelchair Rear Wheel FIGURE 1 Removing/Installing Rear Wheels - Quick-Release Axles Replacing Rear Wheel Handrim WARNING Rear Wheel Mounting Screw Wheelchairs with 300lbs weight limit: DO NOT use composite handrims. Otherwise injury or damage may occur. If the wheelchair is equipped with permanent axles, this procedure must be performed by a qualified technician. 1. Remove the rear wheel from the wheelchair. For non-recliner models, refer to Removing/Installing Rear Wheels on page 55. For 9000XT Recliner, refer to Removing/Installing Rear Wheels on page 77. 2. Remove the mounting screws that secure the handrim to rear wheel. 3. Remove the existing handrim. 4. Install the new handrim by reversing the preceding steps. Part No. 1056953 Handrim FIGURE 2 Replacing Rear Wheel Handrim 57 Invacare® 9000 Series Wheelchair 8 REAR WHEELS WARNING Make sure detent pin and detent balls of the quick-release axles are fully released before operating the wheelchair. 5. Reinstall rear wheel to the wheelchair. Refer to Removing/Installing Rear Wheels on page 55. 6. If the detent balls of the quick-release axles (if applicable) are not protruding past the inside of the axle bushing or there is too much movement of the rear wheel assembly in a back and forth position, refer to Adjusting Quick-Release Axle on page 58. 7. Repeat STEPS 1-6 for the opposite rear wheel if necessary. 8.2 Adjusting Quick-Release Axle 1. WARNING NEVER use quick-release axles on the 9000 XT (models with offset axle option only), 9000XDT or 9000XT recliner wheelchairs. Remove rear wheel and quick-release axle from the wheelchair. Refer to Removing/Installing Rear Wheels on page 55. 2. Depress detent pin in the quick-release axle and slide axle through the rear wheel hub. 3. Release detent pin ensuring that the detent balls are fully released. 4. Increase or decrease end play by adjusting the locknut on the end of the quick-release axle. 5. WARNING Make sure detent pin and detent balls of the quick-release axles are fully released before operating the wheelchair. Keep detent balls clean. Reinstall rear wheel onto the wheelchair. Refer to Removing/Installing Rear Wheels on page 55. Invacare® 9000 Series Wheelchair 58 Part No. 1056953 8 REAR WHEELS Axle Bushing Locknut Detent Balls Detent Pin Axle Spacer (Conventional Arms Only) Rear Wheel Hub Quick-Release Axle FIGURE 3 Adjusting Quick-Release Axle Part No. 1056953 59 Invacare® 9000 Series Wheelchair 9 FRONT CASTERS 9 Front Casters 9.1 WARNING After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Otherwise injury or damage may occur. Installing/Replacing Six or Eight-Inch Front Casters and Forks WARNING If converting from a six-inch caster to an eight-inch caster or vice versa, there are seat-to-floor height adjustments that MUST be made. Therefore, this procedure MUST be performed by a qualified technician. This procedure can be performed if replacing the exact same size front caster. 1. Remove the dust cover. 2. Remove the locknut that secures the fork to the caster headtube. 3. Drop the front caster and fork out of the caster headtube. 9000XDT ONLY - Make sure to reinstall the 2-inch extension spacer. See Detail "A". 4. Slide in the new six/eight-inch front caster and fork. 5. Reassemble by reversing STEPS 1-3. 6. Repeat STEPS 1-5 for the opposite front caster. Invacare® 9000 Series Wheelchair 60 Part No. 1056953 9 FRONT CASTERS 7. To properly tighten caster journal system and guard against flutter, perform the following check: A. Tip back of wheelchair to floor. B. Pivot both forks and casters to top of their arc simultaneously. C. Let casters drop to bottom of arc (wheels should swing once to one-side, then IMMEDIATELY rest in a straight downward position). D. Adjust locknuts according to freedom of caster swing. 8. Test wheelchair for maneuverability. 9. Readjust locknuts if necessary, and repeat STEPS 7-8 until correct. 10. Snap dust cover over the locknut and stem. Dust Cover DETAIL “A” Locknut 2-inch Extension Spacer Caster Headtube Fork Stem Front Caster and Fork FIGURE 1 Installing/Replacing Six or Eight-Inch Front Casters and Forks 9.2 Adjusting Front Caster Mounting WARNING Front Caster mounting adjustments MUST be performed by a qualified technician. Part No. 1056953 61 Invacare® 9000 Series Wheelchair 10 ANTI-TIPPERS/WHEEL LOCKS 10 Anti-tippers/Wheel Locks WARNING After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Otherwise injury or damage may occur. The procedures in this section apply to non-recliner models only except where noted. For the 9000XT recliner, refer to Recliner on page 70. 10.1 Installing/Adjusting Anti-tippers WARNING Anti-tippers are specific to the different seat-to-floor angles and/or seat-to-floor heights. Refer to the chart in this section of the manual for correct usage and adjustment. If these requirements cannot be achieved, DO NOT use the wheelchair. Contact a qualified technician. If changing the seat-to-floor height with or without a change to seat-to-floor angle, the correct anti-tippers MUST be used to maintain a 1-1/2 to 2-inch ground clearance. Seat-to-floor angle of 0° or 3°: If so equipped, anti-tippers MUST be attached at all times. Inasmuch as the anti-tippers are an option for 0° or 3° on this wheelchair (you may order with or without the anti-tippers), Invacare strongly recommends ordering the anti-tippers as a safeguard for the wheelchair user. Seat-to-floor angle of 6°: If changing the seat-to-floor angle to 6°, anti-tippers MUST be ordered and installed. Anti-tippers MUST be fully engaged and release buttons fully protruding out of adjustment holes. ALWAYS use anti-tippers. When outdoors on wet, soft ground or on gravel surfaces, anti tippers may not provide the same level of protection against tipover. Extra caution MUST be observed when traversing such surfaces. Ensure both anti-tippers are adjusted to the same mounting hole. Invacare® 9000 Series Wheelchair 62 Part No. 1056953 10 ANTI-TIPPERS/WHEEL LOCKS Installing Anti-Tippers 1. Remove plug button (not shown) from end of rear frame tubing and install anti-rattles if not already installed. 2. Press the release buttons in and insert the anti-tippers with the anti-tipper wheels pointing toward the ground/floor into the rear frame tubing until the bottom release button locks in place. 3. Anti-Tipper Wheels Measure the distance between the bottom of the anti-tipper wheels and the ground/floor. Anti-Rattle Anti-Tipper A 1½ to 2-inch clearance between the bottom of the anti-tipper wheels and the ground/floor MUST be maintained at all times. Release Buttons Rear Frame Tubing If the distance between the bottom of anti-tipper wheels and the ground/floor is not 1½ to 2-inches, adjust anti-tippers. Refer to Adjusting Anti-Tippers . FIGURE 1 Installing Anti-Tippers ON PAGE 63 Adjusting Anti-Tippers 1. Press the release buttons on the wheeled portion of the anti-tipper and slide it up or down to achieve the 1-1/2 to 2-inch clearance (Detail “A”). 2. Check to make sure that the release buttons are fully engaged in adjustment holes. DETAIL “A” DETAIL “B” Anti-Tipper Height Release Buttons 1½ inches 2 inches Anti-Tipper Length FIGURE 2 Adjusting Anti-Tippers Part No. 1056953 63 Invacare® 9000 Series Wheelchair 10 ANTI-TIPPERS/WHEEL LOCKS Refer to Detail “B” in FIGURE 2 and to the following charts to ensure the correct anti-tipper is installed in the wheelchair. Seat-to-Floor heights are approximate depending on front caster size and type. Anti-Tipper length measurement is taken with the extension tube in the longest position available.The anti-tipper height measurement MUST be taken with the anti-tipper on a flat surface. 9000 XT (SUPER LOW FRAME) CASTER SIZE 6-inch SEAT-TO-FLOOR HEIGHT 13½ and 14½ inches ANTI-TIPPER LENGTH/HEIGHT 10½ / 2-inches ON CHAIR 1360SH OFF CHAIR KIT NUMBER 1064520 9000 XDT (ADULT TALL FRAME) CASTER SIZE SEAT-TO-FLOOR HEIGHT ANTI-TIPPER LENGTH/HEIGHT ON CHAIR OFF CHAIR KIT NUMBER 8-inch 17½ and 19½ inches 11-5/8 / 2-3/4-inches 1360A 1058752 8-inch 21½-inches 13½ / 3½-inches 1360 1058836 9000 XT WITH 0° SEAT-TO-FLOOR ANGLE (ADULT/HEMI FRAME) CASTER SIZE SEAT-TO-FLOOR HEIGHT ANTI-TIPPER LENGTH/HEIGHT ON CHAIR OFF CHAIR KIT NUMBER 8-inch 17½, 18½ inches 13½ / 3½-inches N/A 1058836 6-inch 16½, 17½-inches 13½ / 3½-inches N/A 1058366 15½-inches 11-5/8 / 2-3/4-inches N/A 1058752 Invacare® 9000 Series Wheelchair 64 Part No. 1056953 10 ANTI-TIPPERS/WHEEL LOCKS 9000 XT WITH 3° SEAT-TO-FLOOR ANGLE AND 9000 SL (ADULT/HEMI FRAMES) CASTER SIZE SEAT-TO-FLOOR HEIGHT ANTI-TIPPER LENGTH/HEIGHT ON CHAIR OFF CHAIR KIT NUMBER 8-inch 17½, 18½, 19½-inches 13½ / 3½-inches 1360 1058836 6-inch 15½, 16½, 17½-inches 11-5/8 / 2¾-inches 1360A 1058752 9000 XT WITH 6° SEAT-TO-FLOOR ANGLE (ADULT/HEMI FRAME) CASTER SIZE SEAT-TO-FLOOR HEIGHT ANTI-TIPPER LENGTH/HEIGHT ON CHAIR OFF CHAIR KIT NUMBER 8-inch 17½, 18½, 19½-inches 13½ / 2-7/8-inches N/A 1113766 6-inch 16½, 17½-inches 12½ / 2¾-inches N/A 1113765 15½-inches 9½ / 2-3/8-inches N/A 1113764 10.2 Using/Adjusting Patient Operated Wheel Locks Using Patient Operated Wheel Locks WARNING DO NOT attempt to stop a moving wheelchair with wheel locks. Wheel locks are not brakes. If the wheelchair is equipped with push to lock wheel locks, elevating legrests, and wheel lock extension handles, the wheel lock extension handles MUST be removed before swinging the elevating legrests to the side, otherwise injury or damage may result. Interference between the top of the elevating legrest and the wheel lock extension handle may cause the wheel lock to disengage. Position wheelchair on a flat, level surface to perform this procedure. Ensure the wheelchair is not moving before engaging the wheel locks. Part No. 1056953 65 Invacare® 9000 Series Wheelchair 10 ANTI-TIPPERS/WHEEL LOCKS 1. See Detail “A” for instructions on Push-to-Lock. Refer to Detail “B” for instructions on Pull-to-Lock. 2. Disengage the wheel locks by reversing the directions in STEP 1. Detail “A” Push-To-Lock Pull wheel lock handle toward the tire to disengage wheel lock Detail “B” - Pull-To-Lock Pull wheel lock handle backward toward the tire to engage wheel lock Push wheel lock handle forward away from the tire to engage wheel lock Unlocked Position Unlocked Position Wheel Lock Push wheel lock handle away from the tire to disengage wheel lock Wheel Lock Locked Position Locked Position FIGURE 3 Using Patient Operated Wheel Locks Adjusting Patient-Operated Wheel Locks The push-or-pull-to-lock wheel locks are also an option on the 9000XT Recliner. If wheels are pneumatic, before adjusting or replacing the wheel lock assemblies, ensure that the tires are inflated to the recommended psi on the side wall of tire. The recommended tire pressure is located on the side wall of the tire. 1. Disengage the wheel locks. 2. Perform one of the following: 3. • Bolt-on Wheel locks - Loosen the bolt and locknut that secure the wheel lock to the wheelchair frame. • Clamp-on wheel locks - Loosen the two socket screws that secure the wheel lock to the wheelchair frame. Reposition the wheel lock so that when engaged, the wheel lock shoe embeds the tire 1/8-inch (3/16-inch for pneumatic tires) and holds the occupied wheelchair in place when pushed. 4. Securely tighten the bolt and locknut or socket screws securing the wheel lock to the wheelchair frame. 5. Engage the wheel lock. Invacare® 9000 Series Wheelchair 66 Part No. 1056953 10 ANTI-TIPPERS/WHEEL LOCKS 6. Measure the distance the wheel lock is embedded into the tire as shown in FIGURE 4 on page 68. Any wheel lock adjustment should embed the wheel lock shoe at least 1/8-inch (3/16-inch if pneumatic tire) into the tire when engaged. 7. Repeat STEPS 1-6 until the wheel lock shoe embeds the tire 1/8-inch (3/16-inch for pneumatic tires) and holds the occupied wheelchair in place when pushed. 8. If the measurement of 1/8-inch (3/16-inch for pneumatic tires) can not be achieved, Perform one of the following: • 9. Bolt-on wheel locks - Remove the bolt and locknut that secure the wheel lock to the wheelchair frame and mount the wheel lock in the remaining mounting position. • Clamp-on Wheel locks - Proceed to STEP 9. If wheel lock is unable to properly engage the wheel it may be necessary to install wheel lock shoe extensions. Refer to Installing Wheel Lock Shoe Extensions on page 69. 10. Repeat STEPS 1-9 for the opposite wheel lock. 11. Engage both wheel locks and ensure the occupied wheelchair is held in place when pushed. WARNING If wheel locks DO NOT hold the occupied wheelchair in place, contact a qualified technician. Otherwise injury or damage may occur. Part No. 1056953 67 Invacare® 9000 Series Wheelchair 10 ANTI-TIPPERS/WHEEL LOCKS Bolt-On Wheel Locks Bolt and Locknut Clamp-On Wheel Locks Wheel Lock Handle Mounting Positions Socket Screws 1 /8 inch (3/16 inch pneumatic tires) Wheel Lock Shoe Wheel Lock Clamp Wheel Lock Wheel Lock Tire Wheel Lock Shoe Wheel Lock Shoe Rear Wheel Rear Wheel FIGURE 4 Adjusting Patient-Operated Wheel Locks Invacare® 9000 Series Wheelchair 68 Part No. 1056953 10 ANTI-TIPPERS/WHEEL LOCKS 10.3 Installing Wheel Lock Shoe Extensions 1. Loosen the two set screws on the wheel lock shoe extension until the set screws DO NOT protrude into the slot. 2. Insert the disk wheel lock shoe into the slot in the shoe extension. Ensure the pointed end of the wheel lock shoe extension is facing toward the rear wheel. 3. Position the wheel lock shoe extension so the outside edge is flush with the out side edge of the wheel lock shoe. 4. Securely tighten the two set screws to secure the wheel lock shoe extension to the wheel lock shoes. Set Screws Wheel Lock Shoe Extension Pointed End of Wheel Lock Shoe Extension Slot FIGURE 5 Installing Wheel Lock Shoe Extensions Part No. 1056953 69 Invacare® 9000 Series Wheelchair 11 RECLINER 11 Recliner WARNING After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Otherwise injury or damage may occur. 11.1 Operating Recliner WARNING ALWAYS make sure that the wheelchair is stable before using the recliner option. ALWAYS wear your seat positioning strap. Inasmuch as the seat positioning strap is an option on this wheelchair (you may order with or without the seat positioning strap), Invacare strongly recommends ordering the seat positioning strap as an additional safeguard for the wheelchair user. The seat positioning strap is a positioning strap only. It is not designed for use as a safety device withstanding high stress loads such as auto or aircraft safety belts. If signs of wear appear, strap MUST be replaced IMMEDIATELY. Ensure the spreader bar is attached and secured before using the 9000XT Recliner. LIFT KIT MODELS ONLY - Both spring lift mechanisms MUST be operational before using the recliner. DO NOT operate the recliner option if only one of the spring lift mechanisms is operational. TO HEALTHCARE PROFESSIONALS/ASSISTANTS: Make sure occupant's hands and body are clear of all pinch points before reclining back. Pinch Points exist between spreader bar and recliner mechanism. Use caution, otherwise injury may occur. When returning the occupant of the wheelchair to the full upright position, more body strength will be required for approximately the last twenty degrees of incline (reverse recline). Make sure to use proper body mechanics (use your legs) or seek assistance if necessary to avoid injury. Invacare® 9000 Series Wheelchair 70 Part No. 1056953 11 RECLINER WARNING After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Otherwise injury or damage may occur. LIft kit models only - DO NOT attempt to recline or incline the wheelchair back without occupant. Back will raise abruptly and cause injury. Keep clear when reclining or inclining (reverse recline) chair back to avoid injury. ALWAYS engage both wheel locks while reclining or inclining (reverse recline) the wheelchair. Make sure the patient is properly positioned in the wheelchair before reclining or inclining (reverse recline) to maintain maximum stability and safety. Refer to Stability (Recliner Models Only) on page 22. 1. Unfold wheelchair. Refer to Unfolding and Folding Wheelchair on page 30. 2. Attach spreader bar. Refer to Storing/Replacing Spreader Bar on page 75. 3. Adjust the tightness of the headrest/back upholstery. Refer to Adjusting Headrest/Back Upholstery Tension on page 74. 4. Make sure wheelchair is occupied and on a level surface before reclining. 5. Engage the wheel locks. Refer to Using/Adjusting Wheel Locks on page 78. 6. Inform the occupant of the wheelchair that the wheelchair is about to be reclined. 7. Make sure occupant's hands and body are clear of all pinch points. 8. Stand behind the wheelchair and grasp both push handles firmly. 9. Squeeze release handles. 10. Slowly pull back on the back assembly while squeezing the release handles. 11. When the back reaches the desired angle, slowly let go of the release handles. 12. To return the back to the full upright position, reverse STEPS 8-11 keeping in mind proper body mechanics. Part No. 1056953 71 Invacare® 9000 Series Wheelchair 11 RECLINER Push Handle Release Handle Reclined Position Back Assembly Upright Position FIGURE 1 Operating Recliner Replacing Headrest Pillow 1. 2. Fastening Strips Unfasten straps of headrest pillow from behind headrest upholstery. Secure straps of the new headrest pillow onto fastening strips located on back of headrest upholstery. Headrest Upholstery Strap Strap Headrest Pillow FIGURE 2 Replacing Headrest Pillow Invacare® 9000 Series Wheelchair 72 Part No. 1056953 11 RECLINER 11.2 Replacing Headrest/Back Upholstery Headrest Upholstery 1. 2. Remove the headrest pillow. Refer to Replacing Headrest Pillow on page 72. Remove the six mounting screws that secure the headrest upholstery to the headrest extension tubes. 3. Secure new headrest upholstery onto headrest extension tubes with the existing six mounting screws. 4. Install headrest pillow. Refer to Replacing Headrest Pillow on page 72. Headrest Extension Tube Headrest Upholstery Mounting Screws Back Upholstery Knob Back Upholstery 1. Remove one knob from one side of the spreader bar. 2. Loosen, but DO NOT remove the remaining knob. Mounting Screws To remove and install the bottom two mounting screws of the back upholstery, the wheelchair MUST be partially folded. 3. Remove the twelve mounting screws that secure the back upholstery to the back canes. 4. Secure the new back upholstery to the back canes with the existing twelve mounting screws. Securely tighten. 5. Install the knob removed in STEP 1 to secure spreader bar to side frame. Securely tighten both knobs. Back Cane FIGURE 3 Replacing Headrest/Back Upholstery Part No. 1056953 73 Invacare® 9000 Series Wheelchair 11 RECLINER Adjusting Headrest/Back Upholstery Tension 1. Rotate the spreader bar in one of the following directions: • Counterclockwise (away from back upholstery) to loosen back/headrest upholstery. • Clockwise (towards back upholstery) to tighten back/headrest upholstery. Headrest Upholstery Spreader Bar Back Upholstery FIGURE 4 Adjusting Headrest/Back Upholstery Tension 11.3 Adjusting Seat Depth WARNING Adjusting the seat depth of the 9000XT Recliner MUST be performed by a qualified technician. 11.4 Adjusting Seat Width WARNING Adjusting the seat width of the 9000XT Recliner MUST be performed by a qualified technician. Invacare® 9000 Series Wheelchair 74 Part No. 1056953 11 RECLINER 11.5 Storing/Replacing Spreader Bar Storing Spreader Bar Locking Knob The 9000XT Recliner is folded for either storage or transporting. One side of the spreader bar MUST be removed and placed in a vertical position alongside the recliner tube. Side Frame Spreader Bar Removing From Stored Position 1. 2. Rotate the end of the spreader bar 90o toward the opposite side frame. Install threaded end of locking knob into locknut located on the opposite side frame. Securely tighten both knobs. Recliner Tube Threaded End Locking Knob FIGURE 5 Storing/Replacing Spreader Bar Placing In Stored Position 1. 2. Remove one locking knob from the spreader bar. Loosen the remaining locking knob on the spreader bar. 3. Rotate detached end of the spreader bar 90° down toward floor. Spreader Bar Locking Knobs Side Frame Replacing Spreader Bar 1. 2. 3. Remove both locking knobs that secure the spreader bar to the side frames. Remove existing spreader bar. Side Frame Secure new spreader bar to the side frames with the existing locking knobs. Securely tighten. Part No. 1056953 FIGURE 6 Replacing Spreader Bar 75 Invacare® 9000 Series Wheelchair 11 RECLINER Installing Anti-Tippers 1. 2. DETAIL “A” Install the anti-rattles onto the rear frame tubes if not already in place (Detail “A”). Position the anti-tippers with the anti-tipper wheels pointing toward the ground/floor 3. Press the release buttons. 4. Insert the anti-tippers into the rear frame tubing until the bottom release button locks in place. Release Buttons Rear Frame Tubing Anti-Tipper Wheels Refer to Detail “B” of FIGURE 7 and the following chart to ensure the correct anti-tipper is installed in the wheelchair. Seat-to-floor heights are approximate depending on front caster type. The anti-tipper height measurement MUST be taken with the anti-tipper on a flat surface. Anti-Tipper Anti-Rattle DETAIL “B” Anti-Tipper Height Anti-Tipper Length FIGURE 7 Installing Anti-Tippers Invacare® 9000 Series Wheelchair 76 Part No. 1056953 11 RECLINER 9000 XT RECLINER Wheel Size Rear/Caster Seat-to-Floor Height Anti-Tipper Length/Height On Chair Off Chair Kit Number 24/8-inch 19½-inches 11½ / 2½-inches 1021767 1021767 22/8-inch 18½-inches 10¼ / 1-7/8-inches 1061110 1061110 20/8-inch 17½-inches 10 / 1½-inches 1061109 1061109 11.6 Removing/Installing Rear Wheels WARNING Changing the size of the rear wheel or the seat-to-floor height MUST be performed only by a qualified technician. Use this procedure to replace a rear wheel with one of the same size. With Patient Operated Wheel Locks 1. 2. 3. Remove the axle mounting screw and locknut that secure the patient operated wheel lock, spacers, and rear wheel to the wheelchair frame. Secure rear wheel, patient operated wheel lock, and spacers to wheelchair frame with axle mounting screw and locknut. Securely tighten. Patient Operated Wheel Lock Locknut Adjust the patient operated wheel locks. Refer to Adjusting Patient-Operated Wheel Locks on page 66. Wheelchair Frame Spacers Axle Mounting Screw Rear Wheel FIGURE 8 Removing/Installing Rear Wheels - With Patient Operated Wheel Locks Part No. 1056953 77 Invacare® 9000 Series Wheelchair 11 RECLINER With Attendant Operated Wheel Locks 1. 2. Locknut Remove the axle mounting screw and locknut that secure the rear wheel and spacer to the wheelchair frame. Remove rear wheel from side frame. 3. Secure rear wheel and spacer to wheelchair frame with axle mounting screw and locknut. Securely tighten. 4. Adjust the attendant operated wheel locks. Refer to Adjusting Attendant Operated Wheel Locks on page 79. Axle Mounting Screw Wheelchair Frame Spacer Rear Wheel FIGURE 9 Removing/Installing Rear Wheels - With Attendant Operated Wheel Locks 11.7 Using/Adjusting Wheel Locks For Using and/or Adjusting of Patient Operated Wheel Locks, refer to Using/Adjusting Patient Operated Wheel Locks on page 65. Using Attendant Operated Wheel Locks 1. WARNING DO NOT attempt to stop a moving wheelchair with wheel locks. Wheel locks are not brakes. Perform one of the following: • • Engage - Apply pressure downward on wheel lock handle. Disengage - Lift up on wheel lock handle. Invacare® 9000 Series Wheelchair 78 Part No. 1056953 11 RECLINER Unlocked Position Apply Pressure Here to Engage Locked Position Apply Pressure Here to Disengage FIGURE 10 Using Attendant Operated Wheel Locks Adjusting Attendant Operated Wheel Locks If wheels are pneumatic, before adjusting or replacing the wheel lock assemblies, ensure that the tires are inflated to the recommended psi located on the side wall of tire. 1. Loosen the bolt and locknut that secure the wheel lock to the recliner tube. 2. Adjust the position of wheel lock so that when engaged, the wheel lock shoe embeds the tire 1/8-inch (3/16-inch for pneumatic tires) and holds the wheelchair. 3. Securely tighten the bolt and locknut. 4. Engage wheel lock and push against the wheelchair and determine if wheel lock engages the wheel lock shoe enough to hold the wheelchair. 5. Repeat the above procedures until the wheel lock holds the wheelchair. 6. Repeat STEPS 1-5 for the opposite wheel lock. Ensure the wheel lock shoe completely covers the tire contact area. See Detail "A" for proper positioning of wheel lock shoe. Part No. 1056953 79 Invacare® 9000 Series Wheelchair 11 RECLINER DETAIL “A” - WHEEL LOCK SHOE ENGAGEMENT 1/8-inch (3/16-inch pneumatic tires) Wheel Lock Shoe Wheel Lock Shoe Tire Tire Contact Area Bolt and Locknut Tire Section Recliner Tube Wheel Lock Handle Wheel Lock Shoe Rear Wheel FIGURE 11 Adjusting Attendant Operated Wheel Locks Invacare® 9000 Series Wheelchair 80 Part No. 1056953 11 RECLINER Installing Telescoping I.V. Rod Arm Socket (Outside of Wheelchair Frame) Installing I.V. Holder 1. 2. Remove the rear wheel from the wheelchair. Refer to Removing/Installing Rear Wheels on page 77. Remove the locknut and hex screw that secure the arm socket to the wheelchair frame (Detail “A”). 3. Remove the locknut that secures the back tube to the clevis bracket (Detail “B). 4. Position the top hole on the flat portion of the I.V. holder on the existing pivot screw of the clevis bracket as shown in Detail “B”. 5. Reinstall locknut onto pivot screw. DO NOT tighten yet. 6. Thread the provided mounting screw through the lower hole on the front cylinder section of the I.V. holder, through the side frame, and into the locknut. Turn nut until snug fit is obtained. DO NOT tighten yet. 7. Reinstall the arm to orient front cylinder of I.V. holder. Refer to Removing or Replacing Armrest on page 48. 8. Once front cylinder is oriented for proper clearance of the armrest, securely tighten both locknuts. 9. Install the I. V. rod support tube. Refer to Installing I.V. Rod Support Tube on page 82. Hex Screw DETAIL “A” Locknut Outside of Wheelchair Frame DETAIL “B” Locknut (STEP 6) I.V. Holder (STEP 4) Mounting Screw (STEP 6) Back Tube (STEP 3) Clevis Bracket (STEP 3) Pivot Screw (STEP 4) Locknut (STEPS 3 and 5) FIGURE 12 Installing I.V. Holder Part No. 1056953 81 Invacare® 9000 Series Wheelchair 11 RECLINER Installing I.V. Rod Support Tube 1. The I.V. rod holder MUST already be mounted to the side frame of the wheelchair. Insert the I.V. rod support tube into the rear cylinder of the I.V. rod holder. 2. Turn the I.V. rod support tube until the holes in the I.V. rod support tube align with the holes in the rear cylinder of the I.V. rod holder. 3. Insert mounting screw through rear cylinder, large nylon washer, small nylon washer, steel washer, and into locknut. Securely tighten. When installing the I.V. rod support tube, ensure the adjustment knob is pointing out away from the wheelchair. Locknut The large nylon washer MUST be inserted into hole and pressed in so that it is flush with outside surface of rear cylinder. 4. Reinstall the rear wheel from the wheelchair. Refer to Removing/Installing Rear Wheels on page 77. 5. Adjust I.V. rod to desired height. Refer to Adjusting I.V. Rod on page 82. Small Nylon Washer Large Nylon Washer Loosen adjustment knob. Adjust I.V. Rod to desired height. 3. Securely tighten adjustment knob. Steel Washer I.V. Rod Adjustment Knob I.V. Rod Support Tube I.V. Rod Holder Rear Cylinder Adjusting I.V. Rod 1. 2. Attaching hardware enlarged 3X scale for clarity. Mounting Screw FIGURE 13 Installing I.V. Rod Support Tube - Adjusting I.V. Rod Invacare® 9000 Series Wheelchair 82 Part No. 1056953 12 OPTIONS 12 Options WARNING After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Otherwise injury or damage may occur. The options in this section refer to non-recliner models only. Refer to Recliner on page 70 for 9000XT Recliner options. 12.1 Installing/Cleaning Telescoping I.V. Rod/O2 Holders Installing WARNING The telescoping I.V. rod/O2 holder MUST be checked weekly to ensure it is tightly secured to the wheelchair frame. If there is any looseness whatsoever, tighten the attachment hardware securely before using. TELESCOPING I.V. ROD HOLDER ONLY - Make sure the telescoping I.V. rod is tightly locked before placing I.V. medication on the rod. The telescoping I.V. rod is designed to support I.V. medication only. DO NOT use it to support objects other than I.V. medication. 1. Slide telescoping I.V. rod/O2 holder over the step tube of the wheelchair. Mounting bracket of telescoping I.V. rod/O2 holder should be positioned between the two axle mounting positions on wheelchair frame. 2. Secure telescoping I.V. rod/O2 holder to the wheelchair frame with hex screw, spacer and locknut. 3. Telescoping I.V. Rod Holder Only - Secure the top of the telescoping I.V. rod holder to the wheelchair frame with a tie wrap. Part No. 1056953 83 Invacare® 9000 Series Wheelchair 12 OPTIONS DETAIL “A” - I.V. ROD/O2 HOLDER Telescoping I.V. Rod Holder DETAIL “B” - O2 HOLDER Mounting Bracket Tie Wrap Mounting Bracket Hex Screw Hex Screw Locknut Axle Mounting Positions Spacer Step Tube Locknut Axle Mounting Positions Step Tube Spacer FIGURE 1 Installing/Cleaning Telescoping I.V. Rod/O2 Holders Cleaning 1. WARNING The user and O2 cylinder MUST be removed from the wheelchair when cleaning the O2 holder. Otherwise, injury or damage may occur if cleaning agents come in contact with the O2 regulator. Remove the user, any I.V. medication and the O2 cylinder from the wheelchair. Invacare® 9000 Series Wheelchair 84 Part No. 1056953 12 OPTIONS 2. The telescoping I.V. rod/O2 holders clean easily with any household glass type cleaner. 3. After the cleaning solution has dried, it is safe for the user to re-occupy the wheelchair. 12.2 Installing Crutch and Cane Carrier WARNING Check base weekly to ensure proper placement. When loading the crutch/cane carrier, ensure items are securely placed into the base. Also ensure that there is no interference with folding the wheelchair, the rear wheels, or the swing-back arms. Strap MUST be securely fastened while carrying items. NEVER insert or remove items while wheelchair is moving. 1. 2. Slide the clamp with the base attached over the end of the step tube of the wheelchair. Ensure the base is towards the inside of the wheelchair. Position the base parallel to the step tube. Strap CAUTION Base should be parallel to step tube to avoid bending spokes when folding the wheelchair. 3. Securely tighten the locknut that secures the base to the step tube of the wheelchair. 4. Remove the upper back upholstery screw and washer. 5. Align the strap with the back upholstery screw mounting hole. 6. Reinstall the back upholstery screw and washer and secure the strap to the wheelchair. 7. The base cleans easily with any chrome or glass cleaner. The strap can be cleaned with mild soap and water. Part No. 1056953 Base Step Tube Clamp Locknut FIGURE 2 Installing Crutch and Cane Carrier 85 Invacare® 9000 Series Wheelchair 12 OPTIONS Installing Amputee Bracket Super Hemi Models 1. 2. Wheelchair Frame Spacer Remove the plug button or anti-tipper from the step tube of the wheelchair frame. Slide the amputee attachment over the step tube of the wheelchair. 3. Secure the amputee attachment to the wheelchair with the hew screw, spacer and locknut. 4. Reinstall the plug button or anti-tipper onto the step tube of the wheelchair frame. 5. Repeat STEPS 1-4 for the opposite side of the wheelchair. 6. Reposition the rear wheels. Refer to Removing/Installing Rear Wheels on page 55. Locknut Step Tube Hex Screw Amputee Bracket FIGURE 3 Installing Amputee Bracket 9000SL/XT 1. Refer to the following chart or FIGURE 4 to determine the mounting position of the amputee bracket: SEAT-TO-FLOOR *BRACKET AXLE SPACER POSITION (ON BRACKET) SIDE OF WHEELCHAIR AXLE MOUNTING POSITION (ON WHEELCHAIR) ADULT ADULT HEMI HEMI A B B A DOWN DOWN UP UP RIGHT LEFT RIGHT LEFT TOP TOP BOTTOM BOTTOM * "A" and "B" are stamped on the sides of the amputee bracket. Invacare® 9000 Series Wheelchair 86 Part No. 1056953 12 OPTIONS 2. Install the amputee bracket on the wheelchair frame to the position determined in STEP 1. Make sure the axle spacer is pointing towards the outside of the wheelchair. 3. Install the two hex screws and locknuts that secure the amputee bracket to the wheelchair. 4. Install the rear wheels onto the wheelchair. Refer to Removing/Installing Rear Wheels on page 55. Part No. 1056953 87 Invacare® 9000 Series Wheelchair 12 OPTIONS Bracket “A” Bracket “B” Locknuts Right Left Adult Right Adult Left Axle Spacer Toward Outside of Wheelchair Axle Spacer Toward Outside of Wheelchair Rear View of Amputee Bracket Hex Screws Hemi Left Hemi Right FIGURE 4 Installing Amputee Bracket - 9000SL/XT Invacare® 9000 Series Wheelchair 88 Part No. 1056953 12 OPTIONS 9000XDT 1. Refer to the following chart or FIGURE 5 to determine the mounting position of the amputee bracket: SEAT-TO-FL OOR *BRACKET AXLE SPACER POSITION (ON BRACKET) SIDE OF WHEELCHAIR AXLE MOUNTING POSITION (ON WHEELCHAIR) TALL TALL ADULT ADULT HEMI HEMI A B B A B A DOWN DOWN UP UP UP UP RIGHT LEFT RIGHT LEFT RIGHT LEFT MIDDLE MIDDLE BOTTOM BOTTOM MIDDLE MIDDLE 2. * "A" and "B" are stamped on the sides of the amputee bracket. Install the amputee bracket on the wheelchair frame to the position determined in STEP 1. Make sure the axle spacer is pointing towards the outside of the wheelchair. 3. Install the two hex screws and locknuts that secure the amputee bracket to the wheelchair. 4. Install the rear wheels onto the wheelchair. Refer to Removing/Installing Rear Wheels on page 55. Part No. 1056953 89 Invacare® 9000 Series Wheelchair 12 OPTIONS Bracket “A” Bracket “B” Hemi Left Hemi Right Right Left Adult Right Adult Left Axle Spacer Toward Outside of Wheelchair Hex Screws Rear View of Amputee Bracket Tall Left Tall Right Locknuts FIGURE 5 Installing Amputee Bracket - 9000XDT Invacare® 9000 Series Wheelchair 90 Part No. 1056953 12 OPTIONS 12.3 Installing the Wheel Lock Extension Handle WARNING If the wheelchair is equipped with push to lock wheel locks, elevating legrests, and wheel lock extension handles, the wheel lock extension handles MUST be removed before swinging the elevating legrests to the side, otherwise injury or damage may result. Interference between the top of the elevating legrest and the wheel lock extension handle causes the wheel lock to disengage. For this procedure, refer to FIGURE 6 1. Remove the existing rubber tip from the wheel lock handle (Detail “A”). 2. Install the extension handle over the wheel lock handle (Detail “B”). Detail “B” Detail “A” Wheel Lock Extension Handle Rubber Tip Wheel Lock Handle Wheel Lock Handle Wheel Lock Wheel Lock FIGURE 6 Installing the Wheel Lock Extension Handle Part No. 1056953 91 Invacare® 9000 Series Wheelchair Invacare Corporation USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 www.invacare.com Part No. 1056953 Rev Q - 11/25/13 Canada 570 Matheson Blvd E Unit 8 Mississauga Ontario L4Z 4G4 Canada 800-668-5324
advertisement