H200 Relay


Add to my manuals
2 Pages

advertisement

H200 Relay | Manualzz

H200

Relay

Features

• vertical-operate type relay

• plastic sealed type available

Contact Data

Contact Arrangement ............ 1 Form A / 1 Form B / 1 Form C

Contact Material.................... Ag / AgCdO / Special alloy

Contact Rating ...................... 15 A / 24 VDC / 120 VAC*

7,5 A / 240 VAC*

Switching voltage max. ......... 125 VDC / 250 VAC

Switching power max. .......... 360 W / 1800 VA*

Initial Contact Resistance max. 50 mohms

* Ratings only for Special alloy - type

General Data

Insulation Resistance min. .... 100 Mohms (at 500 VDC)

Dielectric Strength ................ 750 VAC 1 minute

(between open contacts)

1500 VAC 1 minute

(between coil and contacts)

Operate Time ....................... Max. 10 ms

Release Time ....................... Max. 2 ms

Ambient Temperature............ -30 to +70°C (no frost)

Shock Resistance.................. 10 G

Vibration Resistance.............. 10 to 55 Hz at double amplitude of 1,5 mm

Life Expectancy..................... Mechanical 1

×

10 7 ope.min.

Electrical 1

×

10 5 ope. min.

Weight .................................. Approx. 15 gs

3 V

5 V

6 V

9 V

12 V

24 V

48 V

Coil Table

Nominal Voltage

VDC

Coil Resistance (Ohm)

+/- 10% at 20°C

3A & 6A 12A & 15A

25

70

100

225

400

1600

5120

20

56

80

180

320

1280

5120

Operate Voltage (VDC) at 20°C (max.)

2,25

3,75

4,5

6,75

9

18

36

Release Voltage (VDC) at 20°C (min.)

0,3

0,5

0,6

0,9

1,2

2,4

4,8

Nominal Coil Power (mW)

3A & 6A 12A & 15A

360

360

360

360

360

360

450

450

450

450

450

450

450

450

Ordering Information: H200 / F 12 -1 C

Enclosure

F: flow solder

S: sealed (washable)

Contact Arrangement

A = 1 Form A

B = 1 Form B

C = 1 Form C

Nominal Coil Voltage

Refer to coil table

Contact Material

-0 = Ag / 3 A

-1 = AgCdO / 6 A

-2 = Special alloy / 12 A

-3 = Special alloy / 15 A

Dimensions

[in mm]

Useful Curves

Wiring Diagram

[bottom view]

PC Board Layout

[bottom view]

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Questions & Answers

2024-05-19

C C D

How many contacts can the H200 relay handle?
The H200 relay can have a maximum of 3 contacts, with contact arrangements of 1 Form A, 1 Form B, or 1 Form C.
Can the H200 relay handle 240V?
Yes, the H200 relay is capable of switching up to 250 VAC at 3A resistive load, making it suitable for switching 240V.
Can the H200 relay handle DC voltages?
Yes, the H200 relay can switch up to 30 VDC at 3A resistive load.
Can the H200 relay switch 240V DC?
No, the H200 relay should not be used to switch 240V DC as it exceeds the specified voltage limit of 30 VDC, which could lead to damage to the relay.
What are the consequences of exceeding the maximum switching voltage of the H200 relay?
Exceeding the maximum switching voltage can lead to issues such as arcing, contact pitting, contact welding, or permanent damage to the relay, resulting in malfunction, increased resistance, and potential hazards.
How likely is it for the H200 relay's contacts to weld?
The likelihood of contact welding depends on operating conditions, load characteristics, and adherence to specified parameters. Consistently exceeding voltage or current ratings, high inrush currents, frequent switching, or overloading the relay can increase the risk of welding.

Related manuals

advertisement